Ryans Cove_20080911_1013_Linda_LewisHarris, Bobby
From: Linda Lewis [linda.lewis@ncmail.net]
Sent: Thursday, September 11, 2008 10:13 AM
To: David S. Hollis
Cc: Harris, Bobby
Subject: Jeremy Bailey Myrtle Grove Tract
David:
Just a heads up to avoid any confusion about the stormwater rules that will apply to the
proposed wet pond and ORW for this project.
If the project is within 575' of an ORW, it's maximum BUA limit is 25% with an engineered
system to treat all the runoff.
If the project is within 1/2 mile of SA waters, it is limited to 12% built-upon area for low
density, or an engineered system must be provided.
Direct discharges to SA waters are prohibited. Diffuse flow of stormwater at a nonerosive
velocity to a vegetated buffer or other natural area, capable of providing effective
infiltration of the runoff from the 1 year 24 hour storm shall not be considered a direct
discharge. Please note that wetlands will probably not provide effective infiltration, so an
upland or high ground discharge area will be needed.
Linda
!SIG:48c9277196091512310499!
No virus found in this incoming message.
Checked by AVG - http://www.av~.com
Version: 8.0.169 / Virus Database: 270.6.19/1664 - Release Date: 9/11/2008 7:03 AM