W.O. Grubb-09.28.16 Permit SetROTATED WITH WATER HEATER WOOD WATER CLOSET VERTICAL VINYL COMPOSITION TILE UNLESS NOTED OTHERWISE TYPICAL TUBULAR STEEL TEMPERED STRUCTURE (AL) STEEL STANDARD SPECIFICATION (S) SIMILAR SHEET SCHEDULE (ED) SOLID CORE ROOM REINFORCING REFER, REFERENCE PAINT (ED) PLYWOOD OPPOSITE HAND ON CENTER METAL MOUNTED MASONRY OPENING MISCELLANEOUS MINIMUM MECHANICAL METAL BUILDING SUPPLIER MAXIMUM JOIST BEARING INSULATION STD. EXPANSIONEXP. FACE OF GRADE BEAM AIR CONDITIONING HEATING/VENTILATING/ GYPSUM BOARD GAUGE, OR GAGE FIBERGLASS REINFORCED PANEL FACE OF MASONRY FACE OF CONCRETE HOSE BIB H.V.A.C. HDWR. HT. H.C. HEIGHT HARDWARE HOLLOW CORE F.O.G.B. GYP. BD. F.R.P. F.O.M. F.O.C. H.B. GL. GA. FIN. FLR. F.F. EXT. GLASS FINISH FLOOR FLOOR FINISH (ED) EXTERIOR W/ VERT. V.C.T. U.N.O W.C. W.H. WD. TEMP. STRUCT. TYP. T.S. STL. ABOVE FINISHED FLOORA.F.F. EXPANSION JOINT ELECTRIC WATER COOLER CONTINUOUS CONCRETE MASONRY UNIT CONTROL JOINT E.W.C. CONT. CONC. D.S. EQ. ELEC. E.J. ELEV. DWG. DBL. DR. DET. COL. DOWNSPOUT EQUAL ELECTRICAL ELEVATION DRAWING DOOR DETAIL DOUBLE CONCRETE COLUMN C.M.U. BLDG. ANOD. ALUM. CLG. C.J. CLR. CL BOT. BM. BD. ALT. CLEAR CEILING CENTER LINE BOTTOM BEAM BUILDING BOARD ANODIZED ALTERNATE ALUMINUM O.H. ROT. SPEC. SCHED. SIM. SHT. S.C. REINF. PT (D) PLYWD. RM. REF. MTD. O.C. MTL. M.O. MISC. MIN. MECH. M.B.S. MAX. ACOUSTICAL CEILING TILEA.C.T. ADJ.ADJUSTABLE INSUL. JST.BRG. W.O. Grubbs Crane Rental Facility Castle Hayne, NC New Hanover County Lisle Architecture & Design, Inc. (910) 763-6053 : fax (910) 763-4517 Wilmington, North Carolina 28401 614 Market Street LAV.LAVATORY BRG. HT.BEARING HEIGHT T.O.W.TOP OF WALL T.O.S.TOP OF STEEL T.O.P.TOP OF PARAPET T.O.M.TOP OF MASONRY HEIGHT ABOVE FINISHED FLOOR ELEVATION XX/XX 0'-0" First Floor Elevation A A5.1 B 1 C A3.1 C A3.1 XX/XX A LC Bedroom COLUMN CENTERLINE ROOM NAME & NUMBER FACE OF MATERIAL DIMENSION TO CENTERLINE DOOR NUMBER DIMENSION TO A/A5.1 REF. DETAIL WINDOW NUMBER INTERIOR WALL PARTITION TYPE WALL SECTION ENLARGED DETAIL SPOT ELEVATION OR REVISION NUMBER A - DETAIL REVISION AND A5.1 - SHEET BUILDING SECTION BUILDING OR INTERIOR FACE OF STUDF.O.S. 1 101 CR Cover Sheet C1.1 Site Plan CD1 Code Summary CD2 UL Listings LS1 First Floor Life Safety Plan LS2 Second Floor Life Safety Plan SP-1 ADA Notes and Details ARCHITECTURAL A1.1 First Floor Plan A1.2 Enlarged First Floor Plan A1.3 Second Floor A1.4 Enlarged Second Floor Plan A1.5 Roof Plan A2.1 Exterior Elevations A2.2 Exterior Elevations A3.1 Building Sections A3.2 Building Sections A3.3 Building Sections A8.1 Schedules STRUCTURAL S1 Foundation Plan S2 Structural Details W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . Cover Sheet PRESSURE TREATEDP.T. David Sims & Associates (910) 791-8016 : Fax (910) 395-5734 Wilmington, North Carolina 28403 108 Giles Ave. Suite 100 MECHANICAL M1 First Floor Mechanical Plan M2 Second Floor Mechanical Plan M3 Schedules PLUMBING P1 Waste and Vent Plans P2 Water Plans P3 Plumbing Schedules ELECTRICAL E1 First Floor Lighting Plan E2 Second Floor Lighting Plan E3 First Floor Power Plan E4 Second Floor Power Plan Pyrtle Engieering & Design PLLC (910) 270-6288 Hampstead, North Carolina 28443 103 S. Sea Lily Ct. W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . Building Code Data Summary W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . UL Ratings U904 3-HR Rating A NTS U455 3-HR Rating B NTS U432 1-HR Rating C NTS First Floor - Life Safety Plan First Floor Life Safety Plan A 1/4" W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . 1 3HR 3HR 3HR 3HR 3HR 3HR 3HR 3HR 3HR 3HR 3HR 2 3 5 5 A B D E F H 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 1H R 3HR 3HR 3HR 3HR 5.34 62.41.81 BUSINESS OCCUPANCY FIRST FLOOR: 2,638/ 100 GROSS = 27 OCCUPANTS SECOND FLOOR: 2,638/ 100 GROSS = 27 TOTAL OCCUPANTS = 54 MAXIMUM TRAVEL DISTANCE: 200' ACTUAL TRAVEL DISTANCE: 112'-0" LEVEL EXIT WIDTH: 54(.2) = 10.8" ACTUAL EXIT WIDTH: 252" STAIR EXIT WIDTH: 35(.3) = 16.2" ACTUAL STAIR EXIT WIDTH: 48" 2 REQUIRED EXITS IN EACH FIRE AREA 3'- 0 " 18 0 O c c u . 3'- 0 " 18 0 O c c u . ACTUAL REMOTENESS: 79'-7" REQUIR E D R E M O T E N E S S : 8 4 ' - 8 " ( 12) = 42'-4 " S-1 OCCUPANCY FIRST FLOOR: 9,362/ 300 GROSS = 32 OCCUPANTS MAXIMUM TRAVEL DISTANCE: 200' ACTUAL TRAVEL DISTANCE:98'-1" 2 EXITS REQUIRED - 4 EXITS PROVIDED LEVEL EXIT WIDTH: 32(.2) = 6.4" ACTUAL EXIT WIDTH: 144 3'-0" Occu. 3'-0" Occu. 3'-0" Occu. 3' - 0 " 18 0 O c c u . ACT U A L T R A V E L D I S T A N C E : 9 8 ' - 1 " 3' - 0 " 18 0 O c c u . Second Floor - Life Safety Plan Second Floor Life Safety Plan A 1/4" W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . 3HR 3HR3HR3HR3HR3HR3HR3HR3HR3HR3HR3HR 1HR 1H R 1H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 1 2 3 5 5 A B D E F H 5.34 62.41.81 3' - 0 " 18 0 O c c u 3'-0" 180 Occu.4'-0" TRAVEL D I S T A N C E : 1 1 2 ' - 0 " 5' - 0 " W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . ADA Details & Notes ADA Notes **Door Clearances Restroom Details General Notes Toilet Stalls - Plans Restroom Signage 1.THESE GENERAL NOTES SHALL APPLY TO ALL WORK AND ALL DRAWINGS IN THIS SET AND SHALL EXTEND TO ANY CHANGES, EXTRAS, OR ADDITIONS AGREED TO DURING THE COURSE OF THE WORK. 2.DURING BIDDING OR PLACING THE CONTRACTOR MAKE KNOWN TO ARCHITECT ANY LIMITATIONS, EXCLUSIONS, OR MODIFICATIONS TO THE PROJECT DURING THE BIDDING PHASE OF THE PROJECT. UNLESS NOTED THEY WILL BE PRESUMED INCLUDED. 3.ALL CONTRACTORS TO BE INVOLVED IN THIS WORK SHALL CARRY PROPERTY DAMAGE AND PUBLIC LIABILITY INSURANCE AS REQUIRED BY GOVERNMENTAL AGENCIES HAVING JURISDICTION AND COMPLY WITH STATUTORY REQUIREMENTS FOR DISABILITY AND WORKMEN'S COMPENSATION. THEY WILL COMPLY WITH ALL RULES AND REGULATIONS DICTATED BY THE OWNER AND THE CONDITIONS OF THE JOB. INSURANCE SHALL PROTECT THE OWNER AND ANY OTHER GROUP TO BE NAMED FROM LIABILITY DUE TO THE CONTRACTOR'S NEGLIGENCE. A PROPERLY EXECUTED CERTIFICATE OF INSURANCE, AIA DOCUMENT G705, SHALL BE SUBMITTED TO THE ARCHTIECT FACILITIES DEPARTMENT PRIOR TO THE COMMENCEMENT OF ANY WORK. 4.DO NOT SCALE DRAWINGS; DIMENSIONS SHALL GOVERN. DETAILS SHALL GOVERN OVER PLANS AND ELEVATIONS, LARGE SCALE DETAILS SHALL GOVERN OVER SMALL SCALE DETAILS. 5.THERE SHALL BE NO SUBSTITUTION OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED. WHERE THE TERM "OR APPROVED EQUAL" IS USED THE ARCHITECT ALONE SHALL DETERMINE THE EQUALITY BASED UPON THE INFORMATION SUBMITTED BY THE CONTRACTOR. 6.THE GENERAL CONTRACTOR SHALL REVIEW ALL PLANS AND SPECIFICATIONS AND VERIFY ALL GOVERNING DIMENSIONS OF THE BUILDING PRIOR TO THE COMMENCEMENT OF WORK. HE SHALL EXAMINE ALL ADJOINING WORK OR AREAS UPON WHICH THE PERFORMANCE OF HIS WORK IS IN ANY WAY DEPENDENT. ANY VARIATIONS OR DISCREPANCIES SHALL BE REPORTED WITH ALL DUE EXPEDIENCY TO THE ARCHITECT PRIOR TO THE FABRICATION OR ERECTION OF THE WORK IN QUESTION. THE REPRESENTATIVE TO CONTACT IS DAVID LISLE - 910-763-6053 7.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISTRIBUTION OF DRAWINGS TO ALL TRADES UNDER HIS JURISDICTION. 8.ANY INFORMATION REQUIRED BY THE CONTRACTORS THAT IS NOT SHOWN ON DRAWINGS OR OTHER CONTRACT DOCUMENTS SHALL BE REQUESTED BY THE GENERAL CONTRACTOR FROM THE ARCHITECT. 9.THE CONTRACTOR SHALL BE ANSWERABLE TO THE ARCHITECT FOR HIS WORK AND SHALL NOT ACCEPT INSTRUCTION WITHOUT VERIFICATION FROM THE ARCHITECT. CONTRACTOR WILL BE LIABLE FOR ANY EXPENSE CAUSED BY THE EXECUTION OF SUCH WORK WITHOUT SUCH VERIFICATION AND FOR THE EXPENSES CAUSED BY ITS REMOVAL OR CORRECTION. 10.A REPRESENTATIVE OF THE GENERAL CONTRACTOR AUTHORIZED TO DISCUSS THE WORK AND RECEIVE INSTRUCTIONS SHALL BE AT THE JOB SITE AT ALL TIMES THAT WORK IS IN PROGRESS. 11.CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR MISCELLANEOUS STEEL WORK, MOVABLE PARTITION WORK, ALL WOODWORK, DOORS, FRAMES, HARDWARE, FINISHES AND SUCH WORK AS MAY BE SPECIFICALLY REQUESTED IN THE CONTRACT DOCUMENTS TO THE ARCHITECT FOR WRITTEN APPROVAL. SHOP DRAWINGS SHALL SHOW ALL DIMENSIONS AND CONDITIONS AND SHALL BE SUBMITTED IN TRIPLICATE. WHEN THE ARCHITECT REQUIRES THE REVISION AND RESUBMITTAL OF SHOP DRAWINGS, SUCH RESUBMITTAL SHALL OCCUR WITHIN ONE (1) WEEK OF NOTIFICATION OF SUCH REQUIREMENT. 12.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE EXTENT, NATURE, AND SCOPE OF WORK DESCRIBED IN THE CONTRACT DOCUMENTS AND WILL COORDINATE WITH THE ARCHITECT, OR THE ARCHITECT'S REPRESENTATIVE. THE GENERAL CONTRACTOR IS TO PROVIDE ALL LABOR AND MATERIALS NECESSARY TO EXECUTE ALL WORK AS SHOWN ON THESE DRAWINGS WITH THE EXCEPTION OF THOSE ITEMS NOTED AS SEPARATE CONTRACTS OR "N.I.C." HE SHALL BE RESPONSIBLE FOR COORDINATING THIS WORK WITH THAT OF ALL OTHER TRADES INCLUDING THOSE OPERATING UNDER SEPARATE CONTRACT WITH THE LANDLORD AND/OR MSDW 13.ALL WORK SHALL BE PERFORMED BY SKILLED AND QUALIFIED WORKMEN AND IN ACCORDANCE WITH THE BEST PRACTICES OF THE TRADES INVOLVED. CARE SHALL BE TAKEN TO ENSURE COMPLIANCE WITH BUILDING REGULATIONS AND/OR GOVERNMENTAL LAWS, STATUTES, OR ORDINANCES CONCERNING THE USE OF UNION LABOR. 14.ALL MATERIALS SHALL BE NEW, UNUSED, AND OF THE HIGHEST QUALITY IN EVERY RESPECT UNLESS OTHERWISE NOTED. 15.ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE AND IN PROPER ALIGNMENT. 16.MANUFACTURED MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS UNLESS OTHERWISE NOTED. 17.WORK IS TO BE PERFORMED IN ACCORDANCE WITH THE RULES AND REGULATIONS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION AND SHALL CONFORM TO ALL CITY, COUNTY, STATE AND FEDERAL CONSTRUCTION, SAFETY, AND SANITARY LAWS, CODES, STATUTES, AND ORDINANCES. ANY DISCREPANCIES, VARIATIONS, OR OMISSIONS IN THE CONTRACT DOCUMENTS SHALL BE REPORTED PROMPTLY TO THE ARCHITECT. 18.ALL FEES, TAXES, PERMITS, APPLICATIONS, AND CERTIFICATES OF INSPECTION AND THE FILING OF ALL WORK WITH GOVERNMENTAL AGENCIES SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 19.TIME IS OF THE ESSENCE AND THE GENERAL CONTRACTOR SHALL KEEP SUFFICIENT WORKMEN ON THE JOB SITE AT ALL TIMES TO PERFORM THE WORK IN THE MOST EXPEDITIOUS MANNER CONSISTENT WITH GOOD WORKMANSHIP, SOUND BUSINESS PRACTICE, AND THE BEST INTERESTS OF THE OWNER. 20.SHOULD OWNER REQUIRE WORK TO BE PERFORMED ON PREMIUM TIME ABOVE AND BEYOND THAT IMPLIED BY THE CONTRACT DOCUMENTS, THE ARCHITECT SHALL GIVE WRITTEN NOTICE AND THE CONTRACTOR SHALL COMPLY THEREWITH. 21.EACH TRADE WILL BE EXPECTED TO PROCEED IN A FASHION THAT WILL NOT DELAY OR DETAIN THE TRADE FOLLOWING THEM. 22.ALL WORK SHALL BE COMPLETED FOR THE AGREED CONTRACT PRICE WITHOUT RECOURSE TO LABOR STOPPAGES OR REVISIONS OF GOVERNING REGULATIONS, LAWS AND CODES ABOUT WHICH THE CONTRACTOR COULD HAVE REASONABLY BEEN EXPECTED TO HAVE HAD FOREWARNING AND TO HAVE MADE APPROPRIATE CONTINGENCY PLANS PRIOR TO THE SIGNING OF THE CONTRACT. 23.THE CONTRACTOR SHALL NOT PROCEED WITH ANY ADDITIONAL WORK OR CHANGES FOR WHICH HE EXPECTS ADDITIONAL COMPENSATION BEYOND THE CONTRACT AMOUNT WITHOUT WRITTEN AUTHORIZATION FROM THE ARCHITECT. FAILURE TO OBTAIN SUCH AUTHORIZATION SHALL INVALIDATE ANY CLAIM FOR SUCH EXTRA COMPENSATION. 24.ALL INSTALLED PLUMBING, MECHANICAL, AND ELECTRICAL EQUIPMENT SHALL OPERATE AS QUIETLY AND AS FREE OF VIBRATION AS POSSIBLE. 25.ALL WORK AND MATERIALS SHALL BE GUARANTEED AGAINST DEFECTS IN DESIGN, WORKMANSHIP, AND MATERIALS FOR A PERIOD OF AT LEAST ONE (1) YEAR FROM THE ARCHITECTS APPROVAL FOR FINAL PAYMENT. 26.CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES FREE OF ACCUMULATIONS OF WASTE MATERIALS OR RUBBISH CAUSED BY HIS OPERATIONS CONTRACTOR SHALL CONFINE HIS OPERATIONS FOR REMOVAL TO SUCH METHODS AS MAY BE AGREEABLE TO THE OWNER. PREMISES TO BE SWEPT CLEAN OF RELATED CONSTRUCTION DEBRIS DAILY. 27. 27.UPON COMPLETION OF THE WORK THE CONTRACTOR SHALL NOTIFY THE ARCHITECT WHICH SHALL COMPILE A "PUNCH LIST" OF CORRECTIONS AND UNSATISFACTORY AND/OR INCOMPLETE WORK. FINAL PAYMENT WILL BE CONTINGENT ON THE COMPLETION OF THESE ITEMS UNDER THE TERMS OF THE CONTRACT. 28.DURING THE COURSE OF CONSTRUCTION, ACTUAL LOCATIONS SHALL BE INDICATED TO SCALE IN CONTRASTING INK ON THE DRAWINGS FOR ALL RUNS OF MECHANICAL AND ELECTRICAL WORK INCLUDING SITE UTILITIES AND CONCEALED DEVIATIONS FROM THE DRAWINGS. UPON COMPLETION OF THE PROJECT, INCLUDING THE PUNCH LIST, THIS INFORMATION SHALL BE TRANSFERRED TO A SET OF PDF DRAWINGS. THIS SET SHALL BE CONSPICUOUSLY MARKED "AS BUILT SET" AND RETURNED TO THE ARCHITECT WITH ONE (1) COPY TO THE OWNER. 29.DRAWINGS IN THIS SET AND THE DESIGNS THEREON ARE THE PROPERTY OF LISLE ARCHITECTURE & DESIGN , INC. 30.IT IS INTENDED THAT THE GENERAL CONTRACTOR PROVIDE A COMPLETE JOB AND ANY OMISSIONS IN THESE NOTES OR IN THE OUTLINE OF WORK SHALL NOT BE CONSTRUED AS RELIEVING THE GENERAL CONTRACTOR OF SUCH RESPONSIBILITIES AS ARE IMPLIED BY THE SCOPE OF THE WORK EXCEPT FOR ITEMS SPECIFICALLY NOTED. 31.SHOULD ANY PORTION OF THE CONTRACT DOCUMENTS PROVE TO BE, FOR WHATEVER REASONS, UNENFORCEABLE, SUCH UNENFORCEABILITY SHALL NOT EXTEND TO THE REMAINDER OF THE CONTRACT NOR SHALL IT VOID ANY OTHER PROVISION OF THE CONTACT UNLESS IT BE SHOWN THAT THE CONTRACT OR THE PROVISIONS THEREOF ARE DEPENDENT UPON THE UNENFORCEABLE PARTS FOR THEIR MEANING. 32.THROUGHOUT THE DURATION OF THE PROJECT THE GENERAL CONTRACTOR SHALL REFRAIN FROM ACTIONS THAT COULD LEAD TO THE FILING OF A CLAIM OF LIEN AGAINST OWNER BY SUBCONTRACTORS OR SUPPLIERS OF LABOR, MATERIALS, SERVICES, OR EQUIPMENT OR ANY OTHER INDIVIDUAL, COMPANY, OR ENTITY SO ENTITLED UNDER GOVERNING LAWS AND REGULATIONS UNLESS HE CAN SHOW REASONABLE AND JUSTIFIABLE CASE. APPROVAL FOR FINAL PAYMENT SHALL BE CONTINGENT UPON THE GENERAL CONTRACTOR'S OBTAINING AND FURNISHING TO THE ARCHITECT SIGNED RELEASES FROM SUCH INDIVIDUALS, COMPANIES, OR ENTITIES. 33.THE CONTRACTOR SHALL MAKE KNOWN TO THE ARCHITECT ANY DISCREPANCIES THROUGHOUT THE DRAWINGS PRIOR TO CONSTRUCTION. IF THE CONTRACTOR DOES NOT MAKE THEM KNOWN, HE SHALL TAKE RESPONSIBILITY AND LIABILITY FOR THE MOST EXPENSIVE OR HIGHEST QUALITY ITEM. 17" MIN. PROTECTED PIPING 27 " M I N . 9" MI N . MIN. 8" LEVER VALVE MIRROR 6" MAX. 29 " M I N . 34 " M A X . 40 " M A X . 19" MAX. 27 " M I N . 1. Ramps used as a part of a means of egress shall have a running slope not steeper than one unit vertical in 12 units horizontal (8-percent slope). (2012 NCSBC 1010.2, ANSI-2009 405 ) 2.A minimum of one accessible route within the boundary of the site shall be provided from public transportation stops, accessible parking spaces, accessible passenger loading zones, public streets and sidewalks, to the accessible building entrance(s) which they serve. (2012 NCSBC 1104.1, ANSI-2009 5). Signage complying with 1110 indicating the direction to nearest accessible entrance shall be placed at or near each inaccessible entrance such that a disabled person will not be required to retrace the approach route from that inaccessible entrance. The International Symbol of Accessibility shall be used to identify each accessible entrance. (2012 NCSBC 1110.2, ANSI-2009 703) 3.Every required entrance or passage doorway shall be of a size as to permit the installation of a door not less than 3'-0" in width and not less than 6'-8" in height. Doors shall be capable of opening at least 90 degrees and shall be so mounted that the clear width of the doorway is not less than 32". (2012 NCSBC 1008.1.1, ANSI-2009I 404.2.2). 4.Hand activated door opening hardware shall be centered between 30" to 44" above the floor. Latching and locking doors that are hand activated and which are in the path of travel, shall be openable with a single effort by lever type hardware, by panic bars, push-pull activating bars, or other hardware designed to provide passage without requiring the ability to grasp the opening hardware. Locked exit doors shall operate as above in egress direction. Handles, pulls, latches, locks, and other operating devices on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, tight pinching, or twisting of the wrist to operate. Lever operated mechanism, push-type mechanism, and U-shape handles are acceptable designs. When sliding door are fully open, operating hardware shall be exposed and usable from both sides. (2012 NCSBC 1008.1.3.2, ANSI-2009 404.2.6). 5.The width of the level and clear area on the side to which the door swings shall extend 24" past the strike edge of the door for exterior doors and 18" past the strike edge for interior doors. (2012 NCSBC 1008.1, ANSI-2009 404.2.3.1). Refer to Door Clearances this Sheet. 6.The floor or landing shall not exceed 1/2" lower than the threshold of the doorway. Change in level between 1/4" to 1/2" shall be beveled with a slope no greater than 1:2. (2012 NCSBC 1008.1.6, ANSI-2009 404.2.4). 7.Maximum effort to operate doors shall not exceed 8 1/2 lbs. for exterior door and 5 lbs. for interior doors. Such pull or push effort being applied at right angles to hinged doors and at the center plane of sliding of folding doors. Compensating devices or automatic door operators may be utilized to meet the above standards. When fire doors are required, the maximum effort to operate the doors may be increased not to exceed 15 lbs. (2012 NCSBC 1008.1.2, ANSI-2009 404.2.8). 8.Walks and sidewalks shall have a continuous slip resistant surface that shall not be interrupted by steps or abrupt changes in level greater than 1/4". If walks cross driveways or parking lots, then they shall blend to a common level by means of curb cuts, curb ramps or sloped areas whose gradient shall not exceed 1:12. Walks shall maintain a minimum of 48" in width. (2012 NCSBC 1104.2) 20.Toilet flush controls shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. Controls for the flush valves shall be mounted on the wide side of the toilet areas, no more than 44" above the floor. The force required to activate controls shall be no greater than 5 lbs. (ANSI-2009 604.10.6). 21.Toilet Accessories. (ANSI-2009 606) A.A clear floor space of 30" x 48" complying with Section 522(c) shall be provided in front of a lavatory to allow a forward approach. Such clear floor space shall adjoin or overlap an accessible route and shall extend into knee and toe space underneath the lavatory. B.Mirrors shall be mounted with the bottom edge no higher than 40" from the floor. Towel, Sanitary Napkins, Waste Receptacles. Where towel, sanitary napkins, waste receptacles, and other similar dispensing and disposal fixtures are provided, at least one of each type shall be located with all operable parts, including coin slots, within 40" from the finished floor. C.Toilet Tissue Dispensers. Toilet tissue dispensers shall be located on the wall within 12" of the front edge of the toilet seat. 22.Height and Clearances. Lavatories shall be mounted with the rim or counter surface no higher than 34"(865mm) above the finished floor. Provide a clearance of at least 29"(735mm) from the floor to the bottom of the apron. Knee and toe clearance shall comply with Restroom Details this sheet. Lavatories shall be mounted with a minimum distance of 18" to the centerline of the fixture. (ANSI-2009 606.3) 23.Clear Floor Space. A clear floor space of 30" x 48" (760mm x 1220mm) complying with ADA 11.6 shall be provided in front of a lavatory to allow forward approach. Such clear floor space shall adjoin or overlap an accessible route and shall extend a maximum of 19"(485mm) underneath the lavatory. See Restroom Details this sheet. (ANSI-2009 606.2) 24.Exposed Pipes and Surfaces. Hot water and drain pipes under lavatories shall be insulated or otherwise covered. There shall be no sharp or abrasive surfaces under lavatories. (ANSI-2009 606.6) 25.Faucets shall comply with ANSI-2009 606.4. Lever- operated, push-type, and electronically controlled mechanisms are examples of acceptable designs. Self-closing valves are allowed if the faucet remains open for at least 10 seconds. 26.Grab bars, tub and shower seats, fasteners and mounting devices shall be designed for 250 lbs. per linear foot load. (ANSI-2009 607.4). 27.Grab bars shall be located on each side, or one side and the back of the physically disabled toilet stall or compartment and shall be securely attached 33" above and parallel to the floor. (ANSI-2009 604.5). 28.The diameter or width of the gripping surface of the grab bar shall be 1 1/4" to 1 1/2" or the shape shall provide an equivalent gripping surface. (ANSI-2009 609.2). 29.Alcoves. Water fountains shall be located completely within alcoves or otherwise positioned so as not to encroach into pedestrian ways. The alcove in which the water fountain is located shall be not less than 32" in width and 18" in depth. The surface of the path of travel at the water fountain shall be textured so that it is clearly identified by a blind person using a cane. The minimum textured area shall extend from the wall supporting the water fountain to 1'-0" beyond the front edge of the water fountain and shall extend 1'-0" beyond each side of the water fountain, or wing walls shall be provided on each side of the water fountain. The wing walls shall project out from the supporting wall at least as far as the water fountain to within 6" of the surface of the path of travel. Also there shall be a minimum of 32" clear between the wing walls. Size and Approach. The minimum clear ground floor space required to accommodate a single, stationary wheelchair and occupant is 30" x 48". The minimum clear floor or ground space for wheelchairs may be positioned forward or parallel approach to an object. Clear floor or ground space for wheelchairs may be part of the knee space required under some objects. Relationship of Maneuvering Clearance to Wheelchair Spaces. One full unobstructed side of the clear floor or ground space for a wheelchair shall adjoin another wheelchair clear floor space. If a clear floor space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearances shall be provided. (ANSI-2009 602) 30. Water closet compartments shall be equiped with a door that has an automatic closing device, and shall have a clear unobstructed opening width of 32" when located at the end and 34" when located at the side with the door positioned at an angle of 90 degrees from it's closed position. Except for door opening widths and door swings, a clear unobstructed access not less than 44" shall be provided to water closet compartments designed for use for the handicapped/people with disabilities and the space immediately in front of a water closet compartment shall be not less than 48" as measured at right angles to compartment door in it's closed position. (ANSI-2009 604.8.3) 17.Electrical and communications system receptacles mounted on, or built in to, walls or partitions shall be located 15 inches minimum above the finished floor or ground level. (ANSI-2009 308). 16.The mounting height for controls and operating mechanisms in accessible spaces, along accessible routes, or part of accessible elements (e.g. a light switch, dispenser control, or Automatic Teller Machine) shall comply with ANSI-2009 Chapter 3. Forward Reach: (ANSI-2009 308.2) For an unobstructed forward reach, controls and operating mechanisms shall be located between 15 inches minimum to 48 inches maximum above the finished floor or ground level. For a forward reach over an obstruction the maximum height of any control or operating mechanism above the finished floor or ground level shall be: (1) 48" if the depth of the obstruction is less than 20 inches; or (2) 44" if the depth of the obstruction is 20 inches to 25 inches Parallel Reach: (ANSI-2009 308.3) For an unobstructed 10 inches maximum side reach, controls and operating mechanisms shall be located 9 inches minimum to 54 inches maximum above the finished floor or ground level. For a side reach over an obstruction, the obstruction shall have a 34 inches maximum height and a 24 inches maximum depth. Controls and operating mechanisms shall be located 46 inches maximum above the finished floor or ground level. 18.The international symbol of accessibility shall be the standard used to identify facilities that are accessible to, and usable by, physically disabled persons as set forth in these building standards and ADA. The symbol specified above shall consist of a white figure on a blue background. The blue shall be equal to color number 15090 in federal standard 595A. All Signage shall comply with Chapter 11 of the 2012 NC State Building Code (2012 NCSBC 1110.1). 19.At kitchen sinks, faucet controls, and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate controls shall be no greater than 5lbs. Lever-operated, push-type, and electronically controlled mechanisms are examples of acceptable designs. Self-closing valves are allowed if the faucet remains open for at least 10 seconds. Sinks shall be mounted on counter surface no higher than 34" above finish floor and shall provide knee clearance of 27" high (min.) x 30" wide (min.) x 19": deep (min.) underneath sink. (ANSI-2009309.4). 9.Abrupt changes in level along any of accessible route shall not exceed 1/2". When changes in level do occur, they shall be beveled with a slope no greater than 1:2 . (ANSI-2009 303). 11.All public walks that terminate at accessible entrances shall have a clear floor area at the door(s) in compliance with the applicable requirements of ANSI-2009 Table 404.2.3.1. 10.If a public walk has less than 60 inches clear width, then a 60 inches by 60 inches minimum clear passing space shall be provided at intervals not greater than 200 feet. The T-intersection of two walks is an acceptable passing space. (ANSI-2009 403.5.2). 15.If alarm indicating appliances are provided, then audible and visual appliances complying with ANSI-2009 702 shall be provided. 32.Elevator operation shall be automatic with each car equipped with a self-leveling device that will automatically bring the car to the floor landings with a tolerance of 1/2 inch under rated loading to zero loading conditions. Self-leveling shall be automatic and independent of the elevator operating mechanism and shall correct for over-travel and under-travel. (ANSI-2009 407.4.4). 33.Automatic, power operated, horizontal sliding car and hoistway doors shall be provided. (ANSI-2009 407.3). 36.Regardless of the door position, the clear opening shall be 36 inches minimum. (ANSI-2009 407.4.1). 37.A 1-1/4" maximum gap shall be permitted between the car platform sill and the edge of any hoistway landing. ( ANSI-2009 407.4.3) 34.Cabs with center opening doors shall have an 80 inches minimum width and a 51 inches minimum depth. The depth of the cab from the inside face of the cab doors to the wall opposite shall be 54 inches minimum. (ANSI-2009 407.4.1). 35.Cabs with side-slide doors shall have a 68 inches minimum width and 51 inches minimum depth. The depth of the cab from the inside face of the cab floor(s) to the wall opposite shall be 54 inches minimum. ( ANSI-2009 407.4.1) WARNING: Other codes, including but not limited to : Fire Code, Building Code, Elevator Code and Regulations adopted by the State Fire Marshall may contain more restrictive provisions regarding elevator cab. size. Check with the appropriate enforcing officals for details. 38.Call buttons: The common horizontal centerline shall be a nominal 42 inches above the finished floor (36" min. and 48" max. height), except for the photo electric tube by-pass switch, emergency controls shall be grouped in one location in or adjacent to the bottom of the panel and no lower than 2'-11" from the floor. For multiple controls, one set must comply with the height requirements. The emergency telephone shall be positioned at 4'-0" maximum above the floor with a 2'-5" minimum cord. (ANSI-2009 407.4.6). 39.Car control buttons shall be 3/4" minimum and raised 1/8" minimum (+/- 1/32"). Control buttons shall be illuminated, have square shoulders, and be activated by a mechanical motion that is detectable. All buttons shall be designated by a 5/8" minimum Arabic symbol to the left of the control button with a braille symbol below the Arabic symbol. 3/8" minimum shall be provided between rows of control buttons. Raised characters shall be white on a black background. Controls and emergengy equipment identified by raised symbols shall include: door open, door close, alarm bell, emergency stop and telephone. (ANSI-2009 407.4.6). 40.A handrail is required on one wall of the car, preferably the rear. The bar shall be 1 1/2" minimum clear from the wall and 32" (+/-) above the floor. (2012 NCSBC 3001.3). NOTE: Until the office of the State Architect issues specifications for elevator handrails, this Building Department will accept handrails of a size which conforms to that specified for restrooms or stairs or ramps only. 41.A visual and audible signal shall be provided at each hoistway indicating the car answering the call and the direction of travel. Visual signals shall be 2 1/2" x 2 1/2" minimum. Audible signals shall sound once for the up direction and twice for the down direction or shall have verbal annunciations that say up or down. The center line of these signalling fixtures shall be 72" from the lobby floor. (ANSI-2009 407.2.2). 42.Elevator landing jambs shall have the number of the floor for which the jamb is located designated by a 2" minimum Arabic numeral and a raised braille symbol at a height of 5'-0" above the floor and both sides of the door. Raised braille symbol shall be directly to the left of the Arabic symbol and shall be on a contrasting background. (ANSI-2009 407.2.3). 13.Handrails projecting from a wall shall have a space of not less than 1 1/2" between the wall and handrail. (2012 NCSBC 1012.6, ANSI-2009 505.5). 12.Handrail gripping surfaces shall be between 1-1/4" min. and 1-1/2" max. width or outside diameter. The shape shall provide an equivalent gripping surface. Handrail surfaces shall be smooth with no sharp edges. (2012 NCSBC 1012.3, ANSI-2009 505.7) 14.Handrail end shall be rounded or shall return smoothly to the floor, wall or post. (2012 NCSBC 1012.5, ANSI-2009 505.6) ** NOTE: The 2012 NC State Building Code Chapter 11 takes precedence over the notes above. If there are any discrepancies between these drawings and the Code, contact the Architect prior to installation for clarification. 31.Sales & Kitchen Counters shall have a min width of 36" and a max height of 36" (ANSI-2009 904.3) and shall have a 30"Wx48"L minimum clear floor space for each fixture, appliance, storage facility, etc. and a 40" minimum clear aisle. Each accessible kitchen shall have one pull-out worktop with a height of 34" and min. clear width of 30", one shelf at 48" max. above the finished floor, and a sink which complies with ANSI 606 with a 30" min. clear floor width that extends under the sink 19" max. with min. 29" knee clearance.1.BEFORE COMMENCING WORK THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY AREAS THAT HAVE NOT BEEN SATISFACTORILY COMPLETED BY THE LANDLORD AND/OR THE PREVIOUS TENANT TO MEET THE BASE BUILDING REQUIREMENTS (FIREPROOFING, DUCTWORK, CONDITION OF SLAB, CONDITION OF CORE AND DEMISING WALLS, UTILITY HOOKUPS, ELECTRICAL PANELS, ETC.). 2.GREAT CARE SHALL BE EXERCISED TO ASSURE THAT THE BUILDING SHALL BE PROTECTED FROM DAMAGE THAT COULD OCCUR BECAUSE OF THIS WORK AND CONTRACTORS SHALL PROVIDE PROTECTION FOR EXISTING AREAS AND NEW WORK AREAS. ANY DAMAGES DUE TO THIS WORK, OR ACCIDENTS SHALL BE REPAIRED, REPLACED, OR PATCHED AT THE DISCRETION OF THE ARCHITECT. THE CONTRACTOR SHALL BEAR FINANCIAL RESPONSIBILITY FOR SUCH DAMAGE AND ANY WORK UNDERTAKEN TO CORRECT IT. 3.THE CONTRACTOR SHALL EXERCISE GREAT CARE IN PROTECTING ALL MATERIALS EXISTING ON THE JOB FROM DAMAGE AND SHALL MAINTAIN PROTECTION FOR ALL TRAFFIC AREAS OF THE BUILDING TO BE USED DURING THE EXECUTION OF WORK RELATING TO THIS CONTACT WITH THE UNDERSTANDING THAT THE CONTRACTOR WILL RECTIFY ANY DAMAGE ATTRIBUTABLE TO HIS OPERATIONS. 4.IT IS EXPECTED THAT SUFFICIENT LABOR WILL BE PROVIDED SO THAT ACTIVITY FOR ANY GIVEN TRADE WILL NOT BE LIMITED TO ONLY ONE PART OF THE TOTAL WORK AREA. 5.EXISTING CONVECTOR/RADIATOR/PERIMETER ENCLOSURES ARE TO BE COVERED DURING THE WORK AND PROPERLY CLEANED AND VACUUMED PRIOR TO REINSTALLATION AND/OR THE COMPLETION OF CONSTRUCTION. 6.THE GENERAL CONTRACTOR SHALL NOT PLACE CEILING HVAC REGISTERS OR DIFFUSERS WHEREVER SHELVING, FILES, OR OVER FILE UNITS ARE INDICATED ON THE DRAWINGS. 7.THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL EXIT SIGNS AS REQUIRED BY LOCAL CODES UPON APPROVAL OF SIGN LOCATIONS AND STYLES BY THE ARCHITECT AND BUILDING OFFICIALS HAVING JURISDICTION. Upfit Notes ‘5$,/ 6625&+520( 17 " m i n . 1-1/2" 42" min. 33 " - 3 6 " TOILET 36" min. 18" 6" 19 " m a x . max. 12" LC MAX. 12" 3'-5" 3' - 5 " 1'- 6 " First Floor Plan PLAN NORTH First Floor Plan A 1/4" W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . Finish Schedule B 1/4" 1 3HR 3HR 3HR 3HR 3HR 3HR 3HR 3HR 3HR 3HR 3HR 2 3 5 5 A B D E F H 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 1H R 3HR 3HR 3HR 3HR 5.34 62.41.81 Shop 114 Equipment 116 Wash Room 115 3'-4"12'-2"17'-10 3/4"13'-7 1/4"31'-9"31'-0"11'-3"4'-0" A A1.2 76 ' - 0 " 80 ' - 2 " 32 ' - 4 " 30'-6"31'-6"32'-0"31'-0" 60 ' - 8 1 / 2 " 18 ' - 1 1 / 2 " 30'-0"93'-8" 30 ' - 0 " 20 ' - 0 " 30 ' - 0 " 13 ' - 1 0 " 5' - 8 " 13 ' - 0 " A/A2.1 B/ A 2 . 1 A/A2.2 B/ A 2 . 2 4'- 2 " 32 ' - 4 " 22'-6"80'-0"22'-6" Enlarged First Floor Pla PLAN NORTH Enlarged First Floor Plan A 1/4" W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . Typical Mounting Hts.B 1/2" 3HR 3HR 3HR 3HR 3HR 3HR 3HR 3HR 3HR 3HR 3HR 3H R 1H R 3HR 3HR 3HR 3HR Dispatcher 105 Branch Manager 104 Sales 102 Conference 103 Receptionist 101 Work Room 113 Men 110Women 111 Unisex Restroom 112 Service Manager 107 Storage 108 Lounge 109 Lobby 100 Stair C01 Hallway 106 11'-6"11'-0"12'-0"20'-2"12'-0"12'-0" 1'-6"4'-4"4'-6"10'-8"7'-8"7'-4"7'-4"12'-0"6'-0"5'-4"12'-0" 12 ' - 8 " 6' - 0 " 13 ' - 8 " 5' - 0 " 3' - 8 " 8' - 0 " 2' - 0 " 5'-10"5'-8"2'-4"3'-8" 106 A 11 6 107 103 102 100B 110 114 C 117A 105104 11 1 114B 10 6 B 100D 100C 10 0 A E/ A 8 . 1 G/ A 8 . 1 D/ A 8 . 1 F/A8.1 G/ A 8 . 1 A A A A A AA A A A B 1'-6"4'-4"8'-0"3'-8"3'-6"3'-3 1/2"19'-0 3/4" 13 ' - 0 " 6' - 0 " 12 ' - 8 " 17 ' - 0 " 8' - 0 1 / 2 " 7' - 3 1 / 2 " 5'- 4 1 / 2 " 4' - 6 3 / 4 " 5' - 5 " 10 ' - 6 3 / 4 " 6' - 7 1 / 2 " A A3 . 1 A A3 . 1 C/A3.1 D/ A 3 . 1 A/ A 3 . 2 B/ A 3 . 1 A/ A 3 . 3 OP P . UP UP 2 2 2 3 3 A/A2.1 B/ A 2 . 1 3 3 108 11'-6"10'-7"12'-2"6'-8" 109 114 D 11'-0"6'-6"10'-4"11'-3" 1' - 5 " AD A 3'-0"6" 18" 2' - 1 1 " 1' - 5 " AD A 3'-6" 1' - 7 " 4' - 0 " M A X . 5 PAPER TOWEL DISP. 3'-6" 1'-0" 2 1 3' - 5 " 1'- 6 " 3'-5"7 7 3'- 4 " M A X . 2'- 1 0 " M A X . 2' - 5 " M I N . 2'- 2 " M I N . 1'-3" 36 4' - 0 " 4Toilet Accessories Schedule Item Manufacturer 36" Grab Bar 42" Grab Bar Bradley Model 812-42 Framed Mirror 780 Series - Sized to Fit Paper Towel Dispenser Toilet Paper Dispenser Bradley Model 5A10-11 Note: Substitutions Acceptable per Owner and Architects Approval. 1 2 3 4 5 6 7 Bradley Model 2496 18" Grab Bar Bradley Model 812-18 Bradley Model 812-36 Soap Dispenser Bradley Model 6A01-11 Wall Type Schedule 1 U905 3-HR Rated Wall, See A/CD22 NOTE: All Walls are Type 1 Unless Otherwise Noted 4" 20 GA Metal Studs up to 6" Above Ceiling w/ 1 2" Gyp. Bd. Each Side, Ptd. w/ Sound Attenuation Batting w/ 4" Vinyl Base Each Side U455 3-HR Rated Wall, See B/CD23 U432 1-HR Rated Wall, See C/CD24 8" Solid Fille CMU Wall up to 8'-0" AFF w/ Metal Bldg. Girts and Metal Panel up to Underside of Mtl. Deck5 Second Floor Plan PLAN NORTH Second Floor Plan A 1/8" W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . 3HR 3HR3HR3HR3HR3HR3HR3HR3HR3HR3HR3HR 1HR 1H R 1H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 3H R 1 2 3 5 5 A B D E F H 5.34 62.41.81 Shop Below Wash Bay Below Equipment Room Below 2'x10' Prismatic Skylight Typ. A A1.4 22'-6"80'-0"22'-6" 80 ' - 2 " 32 ' - 4 " 125'-0" Wall Type Schedule 1 U905 3-HR Rated Wall, See A/CD22 NOTE: All Walls are Type 1 Unless Otherwise Noted 4" 20 GA Metal Studs up to 6" Above Ceiling w/ 1 2" Gyp. Bd. Each Side, Ptd. w/ Sound Attenuation Batting w/ 4" Vinyl Base Each Side U455 3-HR Rated Wall, See B/CD23 U432 1-HR Rated Wall, See C/CD24 8" Solid Fille CMU Wall up to 8'-0" AFF w/ Metal Bldg. Girts and Metal Panel up to Underside of Mtl. Deck5 Enlarged Second Floor Plan Enlarged First Floor Plan A 1/4" W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . PLAN NORTH 3HR 3HR3HR3HR3HR3HR3HR3HR3HR3HR3HR3HR 1HR 1H R 1H R 3H R 203 B 204A 204 D A/ A 3 . 3 DN DN 4 4 4 3 Storage 203 Office 205 Unfinished Space Conference 200 Womens Room 202 Mens Room 201 Hallway 204 Stair #1 C01 205201 20 0 204B 202 203A 204C A A3 . 1 A A3 . 1 6'-6"22'-6"21'-7"22'-9"6'-8" 30'-10" 1'-6"8'-10" 8'-0"7'-10"33'-2"12'-4" 13 ' - 2 " 5'- 4 " 13 ' - 2 " 5' - 4 1 / 2 " 20 ' - 6 1 / 4 " 6'- 7 1 / 2 " 5'- 8 " 5'-10"4'-8" Stair #2 C02 A A A A A A A 7'- 3 1 / 2 " 25 ' - 0 1 / 2 " 17'-2"16'-0" 47'-10" 7'-0" 2'- 3 " 5'-4" 3 3'-2" 4'-8" 9'- 5 " 1'- 6 " Roof Plan Roof Plan A 1/8" W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . PLAN NORTH RIDGE Sl o p e 12": 1 2 Sl o p e 12": 1 2 6" Alum. Gutter 6" Alum. Gutter 6" Alum. Gutter Standing Seam Metal Roof, TYP. Prismatic Skylight 6" Alum. Gutter Exterior Elevations Front Elevation A 3/16" W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . Right Elevation B 3/16" 1 2.4 4 5.3 6 Cultured Stone Finish Conflex Texture Finish Metal Canopy Alum. Gutter Standing Seam Mtl. Roof Alum. Storefront Wdw. Precast Conc. Trim Split Face Block 3'-0"10'-10"3'-0"16'-10"12'-8"16'-10"3'-0"10'-10"3'-0" 0'-0" T.O. Slab 8'-0" Wdw. Head Ht. 12'-0" T.O. 2nd Flr. 8'-0" Wdw. Head Ht. 24'-0" T.O. Eave Ht. 1.8 ABDEFH Cultured Stone Finish Conflex Texture Finish Metal Canopy Standing Seam Mtl. Roof Alum. Storefront Wdw. Precast Conc. Trim Split Face Block 0'-0" T.O. Slab 8'-0" Wdw. Head Ht. 12'-0" T.O. 2nd Flr. 8'-0" Wdw. Head Ht. 24'-0" T.O. Eave Ht. Exterior Elevations Left Elevation A 3/16" W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . Rear Elevation B 3/16" A B D E F H Cultured Stone Finish Conflex Texture Finish Metal Canopy Standing Seam Mtl. Roof Alum. Storefront Wdw. Precast Conc. Trim Split Face Block 3'-0"3'-0" Stucco Panel 0'-0" T.O. Slab 8'-0" Wdw. Head Ht. 12'-0" T.O. 2nd Flr. 8'-0" Wdw. Head Ht. 24'-0" T.O. Eave Ht. 12356 Stucco Panel Alum. Gutter Standing Seam Mtl. Roof Door Unit as Scheduled CMU 0'-0" T.O. Slab 8'-0" Wdw. Head Ht. 12'-0" T.O. 2nd Flr. 8'-0" Wdw. Head Ht. 24'-0" T.O. Eave Ht. Metal Canopy by PEMB Mfr. Building Sections Partial Building Section A 1/4" W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . Wall Section B 3/4" Wall Section @ Stone C 3/4" Wall Section @ Window D 3/4" SECOND FLOOR OFFICE HALLWAY LOUNGE 4" Reinforced Conc. Slab on 6 Mil Vapor Barrier over 4" Crushed Stone 4" Reinforced Conc.on 1-1/2" Mtl. Deck over Bar Joists Acoustical Ceiling Standing Seam Mtl. Roof Pnl. on 8" Purlins w/ R-30 Insulation B A3.1 A A3.2 12 ' - 0 " 8' - 8 " Precast Conc. Cap Caulk 4" Split Face Block over 1" Airspace on 1 2" Densglass Sheathing w/ R-19 Batt Insulation 8" Header Block 12" CMU 2'- 4 " 4" Crushed Stone 4" Conc. SLab on 6 Mil. Vapor Barrier 1 2" Gyp. Bd. over 6" Mtl. Studs @ 16" O.C. Gutter Eave Strut Standing Seam Mtl. Roof Pnl. on 8" Purlins w/ R-30 Insulation Wall Girt Acoustical Ceiling. 4" Reinforced Conc. Slab over 2" Mtl. Deck Screed Angle Steel Beam Steel Bar Joists (2)2x6 Blocking 12" S.S. Bolts @ 36" O.C. Pipe Sleeve Fascia 4'-0" Decking Fascia Fastener Saddle Bracket 1-1/2" Dia. x 14" Alum. Support Rod Flashing Caulk 6" Sq. Wall Bracket w/ (2) 1 2" S.S. Bolts (2)2x6 Blocking Pipe Sleeve 9'- 4 " 13 ' - 1 0 " 6" 5' - 6 " 6" Conflex Texture Coating, 6" Band Conflex Texture Coating over 1 2" Densglass Conflex Texture Coating, 6" Band Precast Conc. Cap Caulk 4" Split Face Block over 1" Airspace on 12" Densglass Sheathing w/ R-19 Batt Insulation 8" Header Block 12" CMU 2' - 4 " 4" Crushed Stone 4" Conc. Slab on 6 Mil. Vapor Barrier 12" Gyp. Bd. over 6" Mtl. Studs @ 16" O.C. Acoustical Ceiling. 4" Reinforced Conc. Slab over 2" Mtl. Deck Screed Angle Steel Beam Steel Bar Joists Cultured Stone over Mortar Bed on 15# Building Felt over 12" Densglass Sheathing Gable Trim Eave Strut Standing Seam Mtl. Roof Pnl. on 8" Purlins w/ R-30 Insulation Wall Girt Precast Conc. Cap Caulk 4" Split Face Block over 1" Airspace on 12" Densglass Sheathing w/ R-19 Batt Insulation 8" Header Block 12" CMU 4" Crushed Stone 4" Conc. SLab on 6 Mil. Vapor Barrier 12" Gyp. Bd. over 6" Mtl. Studs @ 16" O.C. Wdw. Unit as Scheduled Return Gyp. Bd. to Wdw. Acoustical Ceiling Conflex Texture Coating, 6" Band Conflex Texture Coating over 1 2" Densglass 2' - 4 " Building Sections Partial Wall Section A 1/4" W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . Endwall @ Wash Room B 3/4" Wall Section @ Equipment Room C 3/4" 8" Bond Beam w/ #5 Cont. 8" CMU w/ Zonolite Fill 3-HR Fire Separation Wall - UL U904 #4 @ 48" O.C. Grout Fill Rebar Cells Only Paint Expansion Joint 8" Conc. Slab Reinforced w/ #4 @ 16" O.C. Each Way Expansion Joint 12" Gyp. Bd. over 1-1/2" Furring Conc. Footing and Reinforcement, See Structural 4" Reinforced Conc. Slab over 2" Mtl. Deck Screed Angle Gable Trim Eave Strut Standing Seam Mtl. Roof Pnl. on 8" Purlins w/ R-30 Insulation Roof Beam Wall Girt Metal Wall Panel R-19 Batt Insulation Liner Panel Base Channel 8" Bond Beam w/ #5 Cont. #4@ 48" O.C. Grout Fill Rebar Cells Only 8" Split Face CMU Foam Fill All Cells Expansion Joint 8" Conc. Slab Reinforced w/ #4 @ 16" O.C. Each Way Conc. Footing and Reinforcement, See Structural Paint 8' - 0 " 8" Bond Beam w/ #5 Cont. #4@ 48" O.C. Grout Fill Rebar Cells Only 8" Split Face CMU Foam Fill All Cells Expansion Joint 8" Conc. Slab Reinforced w/ #4 @ 16" O.C. Each Way Expansion Joint 6" Conc. Slab Reinforced w/ 6x6 - W1.4xW1.4 8' - 0 " Paint EQUIPMENT ROOM WASH BAY Base Angle Liner Panel Wall Girt Standing Seam Mtl. Roof Pnl. on 8" Purlins w/ R-30 Insulation 1 2":12 Roof Purlin Building Sections Section @ Stairs A 1/4" W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . 4" Reinforced Conc. Slab over 2" Mtl. Deck Screed Angle 1'-0" 3'- 0 " 112" Dia. Handrail 6 7 8" Riser x 11" Tread 12" Gyp. Bd. on 4" Mtl. Stud Header Wall Beam Bar Joist Acoustical Ceiling 21 R i s e r s i n 1 2 ' - 0 " 4'-0" Schedules Door Elevations A 1/8" W. O . G r u b b 55 3 1 B a r b a d o s B l v d Ca s t l e H a y n e , N C 2 8 4 2 9 Lisle Architecture & Design, Inc. 614 Market Street Wilmington, NC 28401 (910) 763.6053 (o) (910) 763.4517 (f) 323 W. Morgan St. Suite 100 Raleigh, NC 27601 (919) 980.0283 (o) www.LisleArchitecture.com 1 SHEET NUMBER NO . RE V . / SU B . DA T E PR O J E C T N O : 1 6 1 2 4 SHEET TITLE DA T E : 0 9 . 2 7 . 1 6 09 . 2 2 . 1 6 O w n e r R e v . Door Schedule B 1/8" Window Elevations C 1/8" Interior Elevation - Lounge D 1/2" Interior Elevation - Reception E 1/2" Interior Elevation - Work Room F 1/2" Interior Elevation - Work Room G 1/2" A B C D E 7'- 0 " 2" 7'- 0 " 4" 2"VARIES 2"2"VARIES 2" 7'- 0 " 4" 2"VARIES 2" 16 ' - 0 " 16'-0" 8'- 0 " 8'-0" F 8'- 0 " 2" 2"VARIES 2" 5'- 8 " 2'- 4 " A B ALUMINUM STOREFRONT WINDOW - CLEAR SHGC .33 INTERIOR ALUMINUM STOREFRONT WINDOW - CLEAR W/ SLIDING CENTER 4'- 0 " 3' - 6 " 10'-2"3'-0" W36 W36 W12 B36 B36 B36 B36 W36 W30 W36 4" 2' - 8 " 1' - 6 " 3' - 0 " 4" 2' - 8 " 1' - 6 " 3' - 0 " PLam Cabinets w/ (2) Shelves Formica Countertop Copy PLam Cabinets w/ (2) Shelves Formica Countertop Gyp. Bd. Ptd. Gyp. Bd. Ptd. Gyp. Bd. Ptd. Gyp. Bd. Ptd. Formica Countertop Formica Faced Brace Alum. Wdw. 2' - 6 " 5'-0"EQ.EQ. PLam Cabinets w/ Shelf Formica Countertop Gyp. Bd. Ptd.