Loading...
HomeMy WebLinkAbout06072017 June 7 2017 TRC Agenda PackagePage 1 of 1 TECHNICAL REVIEW COMMITTEE AGENDA JUNE 7, 2017 New Hanover County’s Technical Review Committee (TRC) will meet next Wednesday, June 7, 2017 at 2:00 p.m. in the Lucie Harrell Conference Room (601), New Hanover County Government Center, 230 Government Center Drive to review the following: 2:00 p.m. Item 1: Myrtle Oaks (Performance Plan) – Request by Withers & Ravenel for Atlantic Land Partners for TRC to consider preliminary site approval of a 17 lot residential subdivision located near the 1000 block of Grissom Road, west side. Myrtle Oaks Site Plan History None Project Site Plan Data  Zoning District: R-15 Residential  Water Service: Public (CFPUA)  Sewer Service: Public (CFPUA)  Lots: 17  Acreage: 7.07  Road Network Designation: Private  TIA: Not required  Primary Access: Grissom Road  Conservation Resources: None  Comp Plan Future Land Use: General Residential (adopted 2016)  Schools: Codington, Bellamy & CRECC Elementary Myrtle Grove Middle Ashley High (All schools are over-capacity) Staff Recommendations 1) No gates, traffic calming devices or on-street parking unless reviewed by TRC. 2) Road connectivity requirements are not met – waiver requested (see letter). 3) Subdivision and road name approvals. 4) “Passive” rec space needs to be left in natural state. DISCUSSION ITEMS ONLY (No Vote Needed) 2:30 p.m. Item 2: Myrtle Landing Entrance Gate – Request by Jeff Malpass for Tribute Properties to discuss the feasibility of providing a gate near the entrance to Myrtle Landing subdivision and a maintenance building/car wash inside the residential project. The existing project is located near the 7200 block of Myrtle Grove Road. 2:45 p.m. Item 3: Landing at Lewis Plantation – Request by McAdams Homes, LLC to discuss proposed site plan consisting of 236 single family lots, 192 apartment units (428 total units) near the 4600 block of Gordon Road. WithersRavenel Our People. Your Success. 219 Station Road, Suite 101 | Wilmington, NC 28405 t: 910.256.9277 | f: 910.256.2584 | www.withersravenel.com | License No. C-0832 Cary | Greensboro | Pittsboro | Raleigh | Wilmington May 31, 2017 Mr. Sam Burgess Senior Planner New Hanover County – Planning and Zoning 230 Government Center Drive, Suite 110 Wilmington, NC 28403 RE: Myrtle Oaks – Updated TRC Submittal Dear Mr. Burgess: Please see attached revised preliminary plat for the Myrtle Oaks project for your review and approval. We have revised the plans per comments emailed to us on March 23, 2017. For clarity, we have broken down all the comments by stating the staff comment first in italics and are then followed by our responses in bold. PLANNING STAFF OBSERVATIONS: 1. Label “Performance Residential” in title block of site plan. • “Performance Residential” has been added in the title block of the preliminary plat. 2. Label the “passive” and “active” rec space with acreage on site plan. • The passive and active rec space, with respective acreage, has been added to preliminary plat. 3. Land Classification in notes is “General Residential.” • The land classification in the site development data table has been updated to read “General Residential”. 4. Label area between property owners Meredith & Henry (access or drainage/utility easement?) • The 30’ drainage easement in between the aforementioned properties has been labeled on the preliminary plat. 5. A multi-use path may be considered at TRC along project road frontage in conjunction with adopted Greenway Plan. • Noted. This option has been looked at, and we feel that this multi-use path is not necessary because it would not provide any meaningful connectivity to surrounding areas as there are no existing paths or roads to connect to. 6. Links vs Nodes is .67 (1.4 required). May request a waiver front inter-connectivity requirements in writing prior to TRC meeting. • Noted. We are submitting a waiver request with this submittal. 7. Note on plan the approximate number of bedroom per lot. • The approximate number of bedrooms per lot has been added in the site development data table and in the general notes on the preliminary plat. 8. Planning staff to check subdivision and street names (Townsend). • Noted. WithersRavenel Our People. Your Success. Page 2 of 2 9. Add a note concerning street lights to site plan. • Note 16 has been added under general notes to address this comment. 10. Add Private Road cert (unsigned) to plat. • The private road certification (unsigned) has been added to the plat. Please find attached with the letter, the Street Connectivity Waiver Request, an updated Preliminary Plat and the Tree Removal Plan. With this submittal, we feel we have addressed all the concerns and comments from the County Staff. Please let us know if you have any further comments or concerns and thank you for your work on this project thus far. Sincerely WithersRavenel Joe Boyd, PE 910-256-9277 jboyd@withersravenel.com WithersRavenel Our People. Your Success. 219 Station Road, Suite 101 | Wilmington, NC 28405 t: 910.256.9277 | f: 910.256.2584 | www.withersravenel.com | License No. C-0832 Cary | Greensboro | Pittsboro | Raleigh | Wilmington May 31, 2017 David Weaver Technical Review Committee Chairman New Hanover County 230 Government Center Drive, Suite 110 Wilmington, NC 28403 RE: Myrtle Oaks Subdivision NHC Subdivision Ordinance - Section 41-1-7-f – Street Connectivity Waiver Request Dear Mr. Weaver: On behalf of the applicant, we would like to formally request a waiver from the Street Connectivity requirements in the New Hanover County Subdivision Ordinance for the above referenced project. From our interpretation of the ordinance, this project has a link to node ratio of 1.0 (3 links and 3 nodes), which is below the requirement of a ratio of 1.4, stated in the ordinance. Due to the location and site restraints for the project, we are not able to meet the link to node requirements for New Hanover County. Reasons for not being able to meet the requirement include: 1. Access off of Grissom Road is limited to only one entrance. NCDOT will not allow multiple accesses to Grissom Road for the project. 2. The project is boxed in by existing development with no access to stub a connection road to. 3. Limited amount of space for the project to successfully develop the land in a means that is beneficial for the developer and can meet all other local, state and federal regulations. It would be greatly appreciated if the board would consider this waiver request for the Myrtle Oaks Subdivision, so that the development can be constructed to not only the high standards of New Hanover County, but those of the applicant/developer. It is ours and the applicant’s intention to design and construct a community that is of the highest quality that is both aesthetically pleasing and will last far into the future. Thank you for your consideration. Sincerely WithersRavenel Joe Boyd, PE Project Manager 21 9 S t a t i o n R o a d S u i t e 1 0 1 | W i l m i n g t o n , N C 2 8 4 0 5 | t : 9 1 0 . 2 5 6 . 9 2 7 7 | l i c e n s e # : C - 0 8 3 2 | w w . w i t h e r s r a v e n e l . c o m Revisions W: \ 1 6 \ 1 6 - 0 6 0 0 \ 1 6 0 6 0 0 - G r i s s o m R d S u b d i v i s i o n \ C A D \ C o n s t D r a w i n g s \ _ A r c h i v e \ P r e l i m i n a r y P l a t . d w g - W e d n e s d a y , M a y 3 1 , 2 0 1 7 1 1 : 1 0 : 5 5 AM - W H I T E , A L E X Sheet No. Designer Drawn By Date Job No. Wi t h e r s R a v e n e l En g i n e e r s | P l a n n e r s | S u r v e y o r s PRELIMINARY NOT APPROVED FOR CONSTRUCTION MY R T L E O A K S SU B D I V I S I O N NE W H A N O V E R C O U N T Y , N C PE R F O R M A N C E R E S I D E N T I A L PR E L I M I N A R Y P L A T 1 of 2 03160600.00 05/02/2017 AEW JSB GRAPHIC SCALE 1 inch = 50 ft. 50 02550100 TYPICAL STREET SECTION GENERAL NOTES: OWNER:ATLANTIC LAND PARTNERS ADDRESS:2030 EASTWOOD ROAD, SUITE 5 WILMINGTON, NC 28403 PHONE:(910) 679-8638 ATTN:JORDY RAWL NEW HANOVER COUNTY PARCEL NOS.: R07612-001-002-000 R07612-001-002-001 ALT ID NOS.: 313416.92.2632.000 313416.92.5750.000 TOTAL TRACT AREA: 7.07 AC.± ZONING DISTRICT: R-15 LAND CLASSIFICATION: GENERAL RESIDENTIAL DEVELOPMENT DATA: AREA OF LOTS - 4.78 AC.± AREA OF R/W - 0.78 AC.± REC. AREA ACTIVE/PASSIVE - 0.60 AC.± POND AREA - 0.91 AC TOTAL TRACT AREA - 7.07 AC. PERMITTED DENSITY - 7.07 AC. @ 2.5 UNITS/AC. (R-15 - PERFORMANCE RESIDENTIAL) TOTAL UNITS PERMITTED - 17 TOTAL LOTS PROPOSED - 17 OVERALL DENSITY - 2.41 UNITS/AC. AVERAGE LOT SIZE - 12,146 S.F. TOTAL LINEAR FEET IN ROADS - 871 L.F. TOTAL ROAD SURFACES - 20,904 S.F. RECREATION SPACE - 17 LOTS @ .03 AC./UNIT = 0.51 AC. REQUIRED ACTIVE RECREATION AREA - 26,005 S.F. = 0.60 AC.± PASSIVE RECREATION AREA - 39,861 S.F. = 0.91 AC.± TOTAL RECREATION AREA - 1.51 AC. BUILDING SETBACKS: FRONT - 25 FT SIDES - 10 FT REAR - 20 FT APPROXIMATE # OF ROOMS/LOT = 3 SITE DEVELOPMENT DATA VICINITY MAP N E S W SiteSite Masonboro New Hanover County NOT TO SCALE COORDINATION NOTES: 1.THE CONTRACTOR IS REQUIRED TO OBTAIN ANY/ALL PERMITS REQUIRED FOR CONSTRUCTION OF THESE PLANS. 2.ALL WORK IS TO BE IN ACCORDANCE WITH CAPE FEAR PUBLIC UTILITY AUTHORITY, NEW HANOVER COUNTY, AND THE STATE OF NORTH CAROLINA. 3.THE CONTRACTOR IS TO ESTABLISH AND CHECK ALL HORIZONTAL AND VERTICAL CONTROLS TO BE USED WITH THE PROJECT. IN ADDITION, THE CONTRACTOR IS TO COMPUTE THE LAYOUT OF THE ENTIRE SITE PLAN IN ADVANCE OF BEGINNING ANY WORK ASSOCIATED WITH THE SUBJECT PLANS. CONTRACTOR SHALL EMPLOY A PROFESSIONAL SURVEYOR TO PERFORM SITE IMPROVEMENT STAKEOUT(S). 4.ANY TIME WORK IS PERFORMED OFF-SITE OR WITHIN AN EXISTING EASEMENT, THE CONTRACTOR IS TO NOTIFY THE HOLDER OF SAID EASEMENT AS TO THE NATURE OF PROPOSED WORK, AND TO FOLLOW ANY GUIDELINES OR STANDARDS WHICH ARE ASSOCIATED WITH OR REFERENCED IN THE RECORDED EASEMENT. 5.THE CONTRACTOR SHALL SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE NEW HANOVER COUNTY INSPECTOR AND NOTIFY THE ENGINEER AT LEAST 48 HOURS PRIOR TO THE MEETING. AT A MINIMUM; THE CONTRACTOR, COUNTY INSPECTOR, AND ENGINEER SHALL ATTEND THIS MEETING. 6.CONTRACTOR TO COORDINATE WITH TRAFFIC ENGINEERING FOR THE REMOVAL AND STORAGE OF ANY TRAFFIC EQUIPMENT OR SIGNS DURING DEMOLITION, CONSTRUCTION, AND OPENING OF THIS DEVELOPMENT. 7.CONTRACTOR TO COORDINATE WITH THE NEW HANOVER COUNTY ABOUT ANY EQUIPMENT REMOVED, RELOCATED, OR DEMOLISHED DURING THE DEMOLITION, CONSTRUCTION AND OPENING OF THIS DEVELOPMENT. 8.CONTRACTOR TO COORDINATE DIRECTLY WITH ENGINEERING TO DETERMINE IF ANY DRIVEWAY PERMITS/REVISIONS/REVIEW PROCESSES ARE REQUIRED. 9.CONTRACTOR TO COORDINATE WITH TRAFFIC ENGINEERING AT TRAFFIC PLAN FOR THE CLOSURE OF STREETS, SIDEWALKS, OR DRIVEWAYS AND IMPLEMENTATIONS OF THE VEHICLE AND PEDESTRIAN TRAFFIC PLAN TO BE USED FOR THE DURATION OF THIS PROJECT. THE PLAN MUST INCLUDE LOCATIONS OF SIDEWALKS AND CROSSWALKS THAT WILL BE CLOSED, AS WELL AS, LOCATION OF CONSTRUCTION FENCING, AND PROTECTION AREAS. 10.A TEMPORARY DETOUR AND CLOSURE PLAN WILL NEED TO BE FILED WITH NHC 911 FOR THE CLOSURE OF ANY PUBLIC STREETS. GENERAL NOTES: 1.ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY ZONING ORDINANCE AND SUBDIVISION REGULATIONS 2.THE BOUNDARY, TOPOGRAPHY AND UTILITIES SURVEY HAVE BEEN PROVIDED BY ATLANTIC COAST SURVEY. THE VERTICAL DATUM FOR THE GROUND SURVEY FOR THIS PROJECT IS NAVD 88. CONTRACTOR TO VERIFY ALL ELEVATIONS IN THE FIELD. 3.THE TREE SURVEY HAS BEEN PROVIDED BY ATLANTIC COAST SURVEY, LLC. 4.REASONABLE CARE HAS BEEN EXERCISED IN SHOWING THE LOCATION OF EXISTING UTILITIES ON THE PLANS. THE EXACT LOCATION OF ALL EXISTING UTILITIES IS NOT KNOWN IN ALL CASES. THE CONTRACTOR SHALL EXPLORE THE AREA AHEAD OF DITCHING OPERATIONS BY OBSERVATIONS, ELECTRONIC DEVICES, HAND DIGGING AND BY PERSONAL CONTACT WITH THE UTILITY COMPANIES. IN ORDER TO LOCATE EXISTING UTILITIES IN ADVANCE OF TRENCHING OPERATIONS SO AS TO ELIMINATE OR MINIMIZE DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS RESULTING FROM ANY DAMAGE TO THE EXISTING UTILITY LINES INCLUDING LOSS OF UTILITY REVENUES. CONTRACTOR SHALL ARRANGE FOR TEMPORARY SUPPORT OF EXISTING UTILITIES, SUCH AS POLES, CONDUITS, FIBER OPTIC CABLES, TELEPHONE CABLES, WATER LINES, ETC. 5.CONTRACTOR SHALL COMPLY WITH THE LATEST REVISIONS AND INTERPRETATIONS OF THE DEPARTMENT OF LABOR SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION PROMULGATED UNDER THE OCCUPATIONAL SAFETY AND HEALTH ACT. CONTRACTOR SHALL PLAN AND CONSTRUCT WORK SO AS TO CAUSE MINIMUM INCONVENIENCE TO THE OWNER AND THE PUBLIC. 6.CONTRACTOR SHALL PROVIDE, ERECT AND MAINTAIN AT ALL TIMES DURING THE PROGRESS OR TEMPORARY SUSPENSION OF WORK, SUITABLE BARRIERS, FENCES, SIGNS OR OTHER ADEQUATE PROTECTION, INCLUDING FLAGMEN AND WATCHMEN AS NECESSARY TO INSURE THE SAFETY OF THE PUBLIC AS WELL AS THOSE ENGAGED IN THE CONSTRUCTION WORK. CONSTRUCTION SIGNING SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF "CONSTRUCTION AND MAINTENANCE OPERATIONS SUPPLEMENT TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" BY THE DOT. 7.ALL MATERIAL CLEARED OR DEMOLISHED BY THE CONTRACTOR IN ORDER TO CONSTRUCT THE WORK SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE PROPERLY DISPOSED OF OFF-SITE. 8.ALL WORK BY THE CONTRACTOR SHALL BE WARRANTED BY THE CONTRACTOR FOR A PERIOD OF ONE YEAR AFTER THE OWNER ACCEPTS THE WORK. 9.CONTRACTOR SHALL CALL THE NORTH CAROLINA ONE-CALL CENTER AT 811 AND ALLOW THE CENTER TO LOCATE EXISTING UTILITIES BEFORE DIGGING. 10.IF THESE UNITS ARE SOLD AT ANY POINT, THE BUYER MUST RECEIVE A SUBDIVISION STREET DISCLOSURE STATEMENT. PLEASE NOTE THIS ON THE SITE PLAN AND ADVISE THE PROPERTY OWNER OF THIS REQUIREMENT. 11.THIS PROPERTY IS NOT WITHIN ANY FLOOD HAZARD AREA AS EVIDENCED ON N.C. FLOOD MAP 3701683134J. 12.THERE IS NO EVIDENCE OF JURISDICTIONAL WETLANDS ON SITE. 13.THERE IS NO EVIDENCE OF ENDANGERED SPECIES OR HABITAT ISSUES ON THE SITE. 14.THERE ARE CONSERVATION RESOURCE AREAS AFFECTING THIS PROPERTY. 15.THERE WILL BE APPROXIMATELY 3 BEDROOMS PER LOT. 16.WITHERSRAVENEL WILL SUBMIT A LIGHTING PLAN CONFORMING TO ALL NEW HANOVER COUNTY REQUIREMENTS AT A LATER DATE. UTILITY NOTES: 1.EXISTING WATER AND SANITARY SEWER SERVICES ARE CURRENTLY AVAILABLE TO THE SITE FROM PUBLIC SYSTEMS. WATER SERVICE AND SANITARY SEWER SERVICE WILL BE PROVIDED BY CAPE FEAR PUBLIC UTILITY AUTHORITY. 2.ALL UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS, AND TELEPHONE SHALL BE INSTALLED UNDERGROUND. 3.ALL WATER & SEWER UTILITIES TO BE INSTALLED PER CFPUA TECHNICAL SPECIFICATIONS & STANDARDS. 4.PROJECT SHALL COMPLY WITH CAPE FEAR PUBLIC UTILITY AUTHORITY CROSS CONNECTION CONTROL REQUIREMENTS. WATER METER(S) CANNOT BE RELEASED UNTIL ALL REQUIREMENTS ARE MET AND N.C.D.E.N.R. HAS ISSUED THEIR "FINAL APPROVAL". CALL 332-6560 FOR INFORMATION. 5.ALL COMMERCIAL WATER SERVICES AND ANY IRRIGATION SYSTEMS SUPPLIED BY C.F.P.U.A. WATER SHALL HAVE A BACKFLOW PREVENTION DEVICE ACCEPTABLE TO THE COUNTY AND APPROVED BY USCFCCCHR OR ASSE. CALL 332-6560 FOR INFORMATION. 6.WATER AND SEWER SERVICES CAN NOT BE ACTIVATED ON NEW MAINS UNTIL THE ENGINEER'S CERTIFICATION AND AS-BUILTS ARE RECEIVED AND "FINAL APPROVAL" ISSUED BY THE PUBLIC WATER SUPPLY SECTION OF NCDENR, AND "FINAL ENGINEERING CERTIFICATION" ISSUED BY DIVISION OF WATER QUALITY SECTION OF N.C.D.E.N.R. 7.IF CONTRACTOR DESIRES WATER FOR CONSTRUCTION, HE SHALL APPLY IN ADVANCE FOR THIS SERVICE AND MUST PROVIDE A REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTION DEVICE ON THE DEVELOPER'S SIDE OF THE WATER METER BOX. 8.WHEN PVC WATER MAINS AND SERVICES ARE PROPOSED, THE PIPES ARE TO BE MARKED WITH NO. 10 INSULATED COPPER WIRE INSTALLED AND STRAPPED TO THE PIPES WITH DUCT TAPE. THE INSULATED WIRE IS TO BE STRIPPED TO BARE WIRE AND SECURED TO ALL VALVES AND FITTINGS. THIS WIRE IS TO BE ACCESSIBLE IN ALL VALVE AND METER BOXES TO AID IN FUTURE LOCATION OF FACILITIES. 9.THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OR EXISTING UTILITIES DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIRED TO AT LEAST THE QUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM. 10.THE BELLSOUTH CONTACT IS STEVE DAYVAULT, BUILDING INDUSTRY CONSULTANT, AT 910-392-8712. CONTACT HIM PRIOR TO STARTING THE PROJECT IN ORDER TO FACILITATE GOOD COMMUNICATION AND MAXIMUM FLEXIBILITY. 11.THE PROCESS FOR TELEPHONE CABLE PLACEMENT: 11.1.FINAL GRADE WILL NEED TO BE ESTABLISHED. 11.2.POWER WILL PLACE THEIR CABLE FIRST - APPROXIMATELY 3' DEEP. 11.3.BELLSOUTH & CABLE TV WILL THEN PLACE THEIR CABLE AT APPROXIMATELY 2' DEEP. 12.SOLID WASTE DISPOSAL TO BE SERVED BY PRIVATELY CONTRACTED DUMPSTER PICKUP. PROPERTY BOUNDARY CURVE TABLE STORMWATER MANAGEMENT NOTES: 1.STORMWATER MANAGEMENT WILL MEET COUNTY AND STATE REQUIREMENTS. 2.SITE DRAINAGE FLOWS TO INTRACOASTAL WATERWAY WITHIN THE WHITE OAK RIVER BASIN CLASS SA WATERS. PRIVATE ROADS CERTIFICATION: I (WE) HEREBY CERTIFY THAT ALL PRIVATE ROADS AS DEPICTED ON SUBDIVISION PLAT _____________________ HAVE BEEN DESIGNED, INSTALLED, INSPECTED, AND APPROVED IN ACCORDANCE WITH SECTION 52-4 OF THE NEW HANOVER COUNTY SUBDIVISION ORDINANCE AND ALL APPLICABLE NEW HANOVER COUNTY CODES PRIOR TO FINAL PLAT APPROVAL FOR ALL OR A PORTION OF THE SUBDIVISION. BY CERTIFYING THE CONSTRUCTION OF THESE ROADS AS PRIVATE, THERE ARE NO GUARANTEES OR ASSURANCES OF ACCEPTANCE OF SAID ROADS BY THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION. CERTIFIED PROFESSIONAL ENGINEER ___________________________DATE ____________________________ SEAL ___________________________ GRAPHIC SCALE 1 inch = 50 ft. 50 02550100 GENERAL TREE MITIGATION NOTES: 1.REGULATED TREES: HARDWOOD TREES AT LEAST 8" DBH, ALL CONIFER TREES AT LEAST 12" DBH, AND ALL DOGWOODS AND AMERICAN HOLLIES LARGER THAN 4" DBH ANYWHERE ON THE SITE SHALL BE CONSIDERED PROTECTED AND SHALL BE PRESERVED TO THE GREATEST EXTENT PRACTICAL AND INCORPORATED INTO REQUIRED LANDSCAPING. 1.1.264 REGULATED TREES SHALL BE REMOVED 2.SIGNIFICANT TREES: HARDWOOD AND CONIFER TREES AT LEAST 24" DBH, AND DOGWOODS, AMERICAN HOLLIES AND FLOWERING TREES AT LEAST 8" DBH ANYWHERE ON THE SITE SHALL BE CONSIDERED PROTECTED, AND MUST BE PRESERVED OR THEIR REMOVAL MITIGATED AS HEREINAFTER PROVIDED, REGARDLESS OF LOCATION ON THE SITE, UNLESS THE TREES ARE SHOWN TO BE DEAD DYING OR SEVERELY DAMAGED OR DISEASED AS A RESULT OF NATURAL FACTORS. 2.1.29 SIGNIFICANT TREES SHALL BE REMOVED 3.REASONS FOR CLEARING THE NOTED TREES INCLUDE THE FOLLOWING: 3.1.TREES COVER MORE OF THE SITE AREA THAN IS REQUIRED TO BE LANDSCAPED AND THE PARCEL WILL BE FULLY USED. 3.2.IT IS IMPOSSIBLE TO POSITION BUILDINGS ON THE PARCEL AND MEET SETBACK REQUIREMENTS WITHOUT TREE REMOVAL. 4.A MINIMUM OF 15 TREES AT LEAST 2" IN DIAMETER (MEASURED 6: ABOVE THE GROUND) SHALL BE RETAINED OR PLANTED ON THE PARCEL FOR EACH ACRE OR PROPORTIONATE AREA DISTURBED BY DEVELOPMENT. 4.1.SITE AREA: 307,720 SF (7.07 AC.) x 15 = 106.05 107 TREES REQUIRED 143 TREES RETAINED 5.PRIOR TO ANY CLEARING, GRADING OR CONSTRUCTION ACTIVITY, TREE PROTECTION FENCING WILL BE INSTALLED AROUND PROTECTED TREES OR GROVES OF TREES. AND NO CONSTRUCTION WORKERS, TOOLS, MATERIALS, OR VEHICLES ARE PERMITTED WITHIN THE TREE PROTECTION FENCING. LEGEND: REGULATED TREES TO BE REMOVED SIGNIFICANT TREES TO BE REMOVED 21 9 S t a t i o n R o a d S u i t e 1 0 1 | W i l m i n g t o n , N C 2 8 4 0 5 | t : 9 1 0 . 2 5 6 . 9 2 7 7 | l i c e n s e # : C - 0 8 3 2 | w w . w i t h e r s r a v e n e l . c o m Revisions W: \ 1 6 \ 1 6 - 0 6 0 0 \ 1 6 0 6 0 0 - G r i s s o m R d S u b d i v i s i o n \ C A D \ C o n s t D r a w i n g s \ C 1 . 1 T r e e R e m o v a l P l a n . d w g - W e d n e s d a y , M a y 3 1 , 2 0 1 7 1 0 : 3 3 : 1 8 A M - W H I T E , A L E X Sheet No. Designer Drawn By Date Job No. Wi t h e r s R a v e n e l En g i n e e r s | P l a n n e r s | S u r v e y o r s MY R T L E O A K S S U B D I V I S I O N NE W H A N O V E R C O U N T Y , N C 03. 160600 05.08.17 AEW JSB PRELIMINARY NOT APPROVED FOR CONSTRUCTION TR E E R E M O V A L P L A N C1.1 X