Loading...
S21-02 Proposed Concept PlanCOVER SHEET T1 NEW HANOVER COUNTY PLANNING AND LAND USE PERMIT INFORMATION PHONE: ATTN.: 230 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 (910) 798-7165 KEN VAFIER NORTH DRIVING DIRECTIONS VICINITY MAP CONSULTANT NUMBER OF CARRIERS: USE: TOWER TYPE: TOWER HEIGHT: MUNICIPALITY: STATE: PROJECT SUMMARY NEW HANOVER COUNTY NORTH CAROLINA MONOPOLE TOWER 150' (155' TO HIGHEST APPURTENANCE) 3 PROPOSED, 1 FUTURE PROPOSED TELECOMMUNICATIONS TOWER AND UNMANNED EQUIPMENT SITE NAME: WILMINGTON WT RELO SITE #: NC0281 PROPERTY OWNER CONTACTS PHONE: ATTN.: CORNELIA NIXON DAVIS INC 1011 PORTERS NECK RD WILMINGTON, NC 28411 (910) 686-7195 CHARLES LONG POWER COMPANY PHONE: ATTN.: CUSTOMER SERVICE DUKE ENERGY (800) 452-2777 DEVELOPER TOWERCO 2013 LLC 5000 VALLEYSTONE DR #200 CARY, NC 27519 ATTN: DWAYNE LYERLY FLOOD INFO SITE IS LOCATED WITHIN FEMA FLOOD MAP AREA 3720317900K DATED 08/28/2018 WITHIN FLOOD ZONE X. SHEET NO.SHEET TITLE T1 COVER SHEET --SITE SURVEY (SHEET 1 OF 2) --SITE SURVEY (SHEET 2 OF 2) T2 APPENDIX N1 GENERAL NOTES C1 OVERALL PARCEL PLAN C1.1 OVERALL SITE PLAN C2 SITE PLAN C3 FENCE, GATE, AND COMPOUND DETAILS C4 SITE SIGNAGE DETAILS C5 ANTENNA AND TOWER ELEVATION DETAILS L1 LANDSCAPING PLAN SHEET INDEX NEW HANOVER COUNTY SHERIFF PHONE: ATTN.: 316 PRINCESS ST WILMINGTON, NC 28411 (910) 798-4200 CUSTOMER SERVICE NEW HANOVER COUNTY FIRE RESCUE STATION 14 PHONE: ATTN.: 8310 SHIRAZ WAY WILMINGTON, NC 28411 (910) 798-7420 CUSTOMER SERVICE FROM NORTH CAROLINA OFFICE: HEAD SOUTH TOWARD NC-1613/DAVIS DR 144 FT; TURN LEFT ONTO BOULDERSTONE WAY 236 FT; TURN RIGHT ONTO NC-1613/DAVIS DR 0.7 MI; TURN LEFT ONTO WALDO ROOD BLVD 0.7 MI; TURN RIGHT ONTO SW CARY PKWY 5.2 MI; USE THE RIGHT LANE TO MERGE ONTO US-1 N/US-64 E VIA THE RAMP TO RALEIGH 0.2 MI; MERGE ONTO US-1 N/US-64 E 2.1 MI; USE THE RIGHT 2 LANES TO TAKE EXIT 1A TO MERGE ONTO I-40 E TOWARD US-64 E/BENSON/ROCKY MT 8.4 MI; KEEP RIGHT AT THE FORK TO STAY ON I-40 E, FOLLOW SIGNS FOR BENSON/WILMINGTON 115 MI; TAKE EXIT 416A-416B TOWARD TOPSAIL ISLAND/NEW BERN 0.9 MI; MERGE ONTO I-140 E 04 MI; CONTINUE ONTO NC-140 4.9 MI; CONTINUE ONTO US-17 N/MARKET ST 0.4 MI; TURN RIGHT ONTO FUTCH CREEK RD/MARKET ST 1.3 MI; CONTINUE ONTO CHAMP DAVIS RD, DESTINATION WILL BE ON THE LEFT 0.4 MI. WILMINGTON WT RELO SITE ADDRESS (E-911 TBD) 719 CHAMP DAVIS RD WILMINGTON, NC 28411 NEW HANOVER COUNTY LATITUDE: 34° 17' 30.97" N LONGITUDE: 77° 46' 08.73" W TAX/PIN #: R03700-002-002-001 ZONING: R-20 TOWERCO SITE ID: NC0281 at t & SITE KIMLEY-HORN AND ASSOCIATES, INC. 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 PHONE: (919) 653-2942 ATTN.: AVERY FANN PARENT PARCEL: R03700-002-002-001 ZONING: R-20 APPENDIX T2 SITE NAME: WILMINGTON WT RELO SITE #: NC0281 N/A N/AN/A N/AN/AN/A N/AN/A N/AN/A NOTE: SCOPE OF WORK INCLUDES INSTALLATION OF CAST IN PLACE CONCRETE PAD, PREFABRICATED EQUIPMENT CABINETS AND GENERATOR. NO NEW BUILDING BEING CONSTRUCTED. 1.00 GENERAL NOTES GENERAL NOTES N1 SITE NAME: WILMINGTON WT RELO SITE #: NC0281 SURVEY NOTE: NORTH SCALE: 1" = 450' OVERALL PARCEL PLAN1 C1 OVERALL PARCEL PLAN C1 SITE NAME: WILMINGTON WT RELO SITE #: NC0281 NORTH SCALE: 1" = 80' OVERALL SITE PLAN1 C1.1 OVERALL SITE PLAN C1.1 SURVEY NOTE: SITE NAME: WILMINGTON WT RELO SITE #: NC0281 NORTHSCALE: 1" = 20' SITE PLAN1 C2 SITE PLAN C2 SITE NOTES: SITE NAME: WILMINGTON WT RELO SITE #: NC0281 FENCE NOTES: FENCE, GATE, AND COMPOUND DETAILS C3 NOT TO SCALE CHAIN LINK FENCE AND GATE ELEVATION1 C3 NOT TO SCALE MUSHROOM STOP2 C3 NOT TO SCALE SITE COMPOUND SURFACE DETAIL3 C3 NOT TO SCALE SECTION AT FENCE4 C3 SITE NAME: WILMINGTON WT RELO SITE #: NC0281 YELLOW BACKGROUND w/ BLACK LETTERING 3 NOTICE-RFE SIGN Beyond this point:Radio frequency fields at this site may exceed FCCrules for human exposure. For your safety, obey all posted signs and site guidelines for working in radio frequency environments. All personnel should have electromagnetic energy (EME) awareness training. All personnel entering this site must be authorized. Obey all posted signs. Assume all antennas are active. Before working on antennas, notify owners and disable appropriatetransmitters. Maintain minimum 3 feet clearance from all antennas. Do not stop in front of antennas. Use personal RF monitors while working near antennas. Never operate transmitters without shields during normal operation. Do not operate base station antennas in equipment room. NOTICE In accordance with Federal CommunicationsCommission rules on radio frequency emissions 47 CFR 1.1307(b) NOTICE 1 NO-TRESPASSING SIGN BLACK LETTERING WHITE BACKGROUND w/ BLACK LETTERING WHITE BACKGROUND w/ RADIO FREQUENCY ENVIRONMENT AREAAUTHORIZED PERSONNEL ONLY BEYOND THIS POINT! Personnel proceeding beyond this poinrt must obey all posted signs, site guidelines and Federal Regulations for working in radio frequency environments. In accordance with Federal Regulationson radio frequency emissions. WHITE LETTERING BLUE BACKGROUND w/NOTICE 6 NOTICE-RF SIGN (BLUE) 12" WIDE X 18" HIGH BLACK LETTERING YELLOW BACKGROUND w/ BLACK LETTERING WHITE BACKGROUND w/ Beyond this point:Radio frequency fields at this site may exceed FCCrules for human exposure. For your safety, obey all posted signs and site guidelines for working in radio frequency environments. In accordance with Federal Communications Commission rules on radio frequencyemissions 47 CFR 1.1307(b) BLACK LETTERING YELLOW BACKGROUND w/!CAUTION BLACK LETTERING WHITE BACKGROUND w/ BLACK LETTERING RED BACKGROUND w/ BLACK LETTERING RED BACKGROUND w/! NO TRESPASSING VIOLATORS WILL BE PROSECUTED WARNING XXXXXXX RED LETTERING WHITE BACKGROUND w/ WHITE W/BLACK LETTERING 4 WARNING-RF SIGN (RED) 7 FCC REGISTRATION SIGN 12" WIDE X 18" HIGH 20 WIDE X 4" HIGH 5 CAUTION-RF SIGN (YELLOW) 12" WIDE X 18" HIGH WHITE BACKGROUND w/ BLACK LETTERING WHITE BACKGROUND w/ BLACK LETTERING WHITE LETTERING GREEN BACKGROUND w/ This is a TowerCo Antenna Site Site ID: For information call: 2 TOWERCO - SITE ID SIGN 12" HIGH X 24" WIDE (OPERATIONS PROVIDED) 844-218-8549 INFORMATION 18" HIGH X 24" WIDE (OPERATIONS PROVIDED) 12" HIGH X 18" WIDE (OPERATIONS PROVIDED) FCC TOWER REGISTRATION NO. NC0281 SITE SIGNAGE DETAILS C4 NOT TO SCALE SIGN PLACEMENT PLAN VIEW1 C4 NOT TO SCALE TYPICAL SIGNS AND SPECIFICATIONS2 C4 NOT TO SCALE SIGN PLACEMENT FRONT GATE VIEW3 C4NORTH SITE NAME: WILMINGTON WT RELO SITE #: NC0281 FOR ILLUSTRATIVE PURPOSES ONLY- NO SIGNATURE REQUIRED ANTENNA AND TOWER ELEVATION DETAILS C5 NOT TO SCALE MONOPOLE TOWER ELEVATION1 C5 NOT TO SCALE ANTENNA AND EQUIPMENT SCHEDULE2 C5 NOT TO SCALE ANTENNA ORIENTATION PLAN3 C5 SITE NAME: WILMINGTON WT RELO SITE #: NC0281 NOTES: LANDSCAPING PLAN L1 SITE NAME: WILMINGTON WT RELO SITE #: NC0281 GENERAL LANDSCAPE NOTES: 1.THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF HIS WORK WITH THAT OF ALL OTHER CONTRACTORS. THIS PLAN DOES NOT GUARANTEE THE EXISTENCE OR NON-EXISTENCE OF ANY UTILITIES. PRIOR TO COMMENCEMENT OF ANY WORK, THE LANDSCAPE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL ABOVE GROUND AND UNDERGROUND UTILITIES. 2.THE QUALITY AND SIZE OF ALL PLANT MATERIAL SHALL CONFORM TO THE MOST CURRENT STANDARDS AS SET FORTH IN ANSI Z60.180 - AMERICAN STANDARD FOR NURSERY STOCK. 3.ALL DISTURBED AREAS NOT COVERED BY HARDSCAPE OR PLANT MATERIALS SHALL BE COVERED WITH SEED AND STRAW. 4.PLANT SUBSTITUTION MAY BE PERMITTED ONLY AFTER PROOF THAT SPECIFIED PLANTS ARE UNAVAILABLE AND THE REQUEST HAS BEEN SUBMITTED TO THE OWNER OR LANDSCAPE ARCHITECT. THE CONTRACTOR SHALL PROVIDE THE NEAREST EQUIVALENT OBTAINABLE SIZE AND VARIETY OF THE PLANT HAVING THE SAME ESSENTIAL CHARACTERISTICS AS THE PLANT SPECIFIED 5.MINOR PLANT LOCATION ADJUSTMENTS MAY BE MADE IN THE FIELD TO ENSURE ACCESS TO UTILITY JUNCTION BOXES, FREE SITE LIGHTING OF FUTURE TREE CANOPY INTERFERENCE AND ALLOW UNINHIBITED PEDESTRIAN / VEHICULAR CIRCULATION ON ALL PAVEMENTS OR FOUNDATIONS. 6.ALL SHRUB MASSES OF TWO OR MORE SHALL BE EDGED INTO A PLANTING BED AND MULCHED PER DETAIL. ALL INDIVIDUAL TREES AND SHRUBS SHALL HAVE A MULCH SAUCER EQUAL IN DIAMETER TO THE PLANTING PIT DIAMETER AND SHALL BE MULCHED AS SHOWN ON THE DETAILS. UNLESS OTHERWISE INDICATED, ALL BED EDGES SHALL BE A DEEP CUT CLEAN SPADE EDGE. 7.THE CONTRACTOR SHALL VERIFY THAT EACH TREE OR SHRUB PIT WILL DRAIN BEFORE INSTALLING PLANT MATERIAL. HE SHALL FILL THE HOLE WITH SIX INCHES (6") OF WATER THAT SHOULD PERCOLATE OUT WITHIN TWENTY-FOUR HOURS. SHOULD ANY AREA NOT DRAIN PROPERLY, A PERFORATED DRAIN LINE SHALL BE INSTALLED, OR THE PLANTS RELOCATED. 8.THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY IF HE ENCOUNTERS ANY UNSUITABLE SURFACE OR SUBSURFACE DRAINAGE CONDITIONS, SOIL DEPTH, LATENT SOILS, HARD PAN, UTILITY LINES, OR OTHER CONDITIONS THAT WILL JEOPARDIZE THE HEALTH AND VIGOR OF THE PLANTS. SHOULD THE CONTRACTOR NOT NOTIFY THE OWNER OF A PROBLEM AREA, HE WARRANTS THAT THE AREAS ARE SUITABLE FOR PROPER GROWTH AND DEVELOPMENT OF ALL PLANTS INSTALLED. 9.THE CONTRACTOR SHOULD VERIFY LANDSCAPING/TREE PLANTING LOCATIONS WITH THE PUBLIC UTILITIES DEPARTMENT TO AVOID CONFLICTS WITH WATER, SEWER, AND GAS LINES. 10.PLANTS SHALL BE SO TRAINED IN DEVELOPMENT AND APPEARANCE AS TO BE UNQUESTIONABLE SUPERIOR IN FORM, COMPACTNESS AND SYMMETRY. THEY SHALL BE SOUND, HEALTHY, VIGOROUS, WELL BRANCHED AND DENSELY FOLIATED WHEN IN LEAF, AND FREE OF DISEASE AND INSECT ADULT EGGS, PUPAE OR LARVAE. THEY SHALL HAVE HEALTHY, WELL-DEVELOPED ROOT SYSTEMS AND SHALL BE FREE FROM PHYSICAL DAMAGE OR OTHER CONDITIONS THAT WOULD PREVENT THRIVING GROWTH. 11.THERE SHALL BE NO CIRCLING OR GIRDLING ROOTS. CIRCLING ROOTS SHOULD BE CUT IN AT LEAST ONE PLACE. 12.THERE SHOULD BE ONE DOMINANT LEADER TO THE TOP OF THE TREE WITH THE LARGEST BRANCHES SPACED AT LEAST 6 INCHES APART. THERE CAN BE TWO LEADERS IN THE TOP 10% OF THE TREE IF IT IS OTHERWISE OF GOOD QUALITY. 13.THE TREE CANOPY SHOULD BE SYMMETRICAL AND FREE OF LARGE VOIDS. CLEAR TRUNK SHOULD BE NO MORE THAN 40% OF TREE HEIGHT UNLESS OTHERWISE SPECIFIED IN THE PLANTING SPECIFICATIONS. CLEAR TRUNK SHALL BE OF SUFFICIENT HEIGHT TO CLEAR SURROUNDING USES THAT MAY BE IMPACTED BY THE FUTURE GROWTH OF THE TREE. 14.OPEN TRUNK AND BRANCH WOUNDS SHALL BE LESS THAN 10% OF THE CIRCUMFERENCE AT THE WOUND AND NO MORE THAN 2 INCHES TALL. PROPERLY MADE PRUNING CUTS ARE NOT CONSIDERED OPEN TRUNK WOUNDS. THERE SHOULD BE NO CONKS OR BLEEDING, AND THERE SHOULD BE NO SIGNS OF INSECTS OR DISEASE ON MORE THAN 5% OF THE TREE. 15.IF ANY OF THE ABOVE CONDITIONS ARE NOT MET, TREES MAY BE REJECTED. 16.TREE PROTECTION DEVICES MUST BE INSTALLED AND INSPECTED PRIOR TO ANY CLEARING, GRUBBING, OR GRADING OF THE SITE BY THE LOCAL ARBORIST. LANDSCAPING TO BE REMOVED SYMBOL QTY. NAME ORDINANCE SCALE: 1" = 20' LANDSCAPING PLAN1 L1 NORTH