Loading...
HomeMy WebLinkAbout2021-04-27 Site Plan Submittal CombinedSITE PARCEL ID NUMBER:R04000-001-012-000 TOTAL SITE ACREAGE:±65.47 AC CURRENT ZONING:I-2-INDUSTRIAL DISTRICT SITE DATA SITE ACREAGE AS PART OF THIS DEVELOPMENT:±65.47 AC PROPOSED ZONING:I-2-INDUSTRIAL DISTRICT PROPOSED LAND USE:PARK/OPEN SPACE FEMA REGULATIONS CURRENT LAND USE:730-OFFICE AND PROFESSIONAL DISTURBED AREA 100-YEAR BASE FLOOD ELEVATION 500-YEAR BASE FLOOD ELEVATION NO FLOODPLAIN OR FLOODWAY PRESENT ON SITE ±21.5 AC N/A N/A BUILDING REQUIREMENTS FRONT SETBACK: 50' MAXIMUM HEIGHT: 30' SIDE SETBACK: 20' PARKING SUMMARY CLIENT X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - C S 1 . d w g , 4/ 2 7 / 2 0 2 1 1 : 1 1 : 3 0 P M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com CONTACT PROJECT DIRECTORY 205 SUTTON STEAM PLANT ROAD WILMINGTON, NORTH CAROLINA 28401 SITE PLAN SUBMITTAL PROJECT NUMBER: WLM-17000 DATE: APRIL 27, 2021 VICINITY MAP N.T.S. REVISIONS N0.DATE CONSTRUCTION DRAWINGS FOR: REGIONAL ATHLETIC COMPLEX CITY OF WILMINGTON REGIONAL SPORTS COMPLEX WILMINGTON, NC 28401 PROJECT NUMBER: WLM-17000 CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 RACHEL COTTER cotter@mcadamsco.com PHONE: 919. 361. 5000 x132 SHEET INDEX 1 - 3 EXISTING CONDITIONS C1.01 OVERALL DEMOLITION PLAN C1.02 CONTEXT PLAN C2.00 OVERALL SITE PLAN C2.01 SITE PLAN - AREA A C2.02 SITE PLAN - AREA B C2.03 SITE PLAN - AREA C C2.04 SITE PLAN - AREA D C3.00 OVERALL GRADING PLAN C3.01 GRADING PLAN - AREA A C3.02 GRADING PLAN - AREA B C3.03 GRADING PLAN - AREA C C3.04 GRADING PLAN - AREA D C4.00 OVERALL UTILITY PLAN C4.01 OVERALL UTILITY PLAN C4.02 UTILITY PLAN - SANITARY SEWER PROFILE C4.11 UTILITY PLAN - AREA A C4.12 UTILITY PLAN - AREA B C4.13 UTILITY PLAN - AREA C C6.00 EROSION CONTROL PLAN - BASE BID C6.01 EROSION CONTROL DETAILS C6.02 EROSION CONTROL DETAILS C6.03 EROSION CONTROL DETAILS C8.00 SITE AND AMENITY DETAILS C8.01 SITE AND AMENITY DETAILS C8.02 SITE AND AMENITY DETAILS C8.03 WATER DETAILS C8.04 STORM DRAINAGE DETAILS PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION OWNER:CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PREPARED BY:MCADAMS COMPANY 2905 MERIDIAN PARKWAY DURHAM, NORTH CAROLINA 27713 919. 361. 5000 COTTER@MCADAMSCO.COM C10.00 STORMWATER CONTROL MEASURE PLAN & DETAILS L1.00 OVERALL LANDSCAPE PLAN L1.01 LANDSCAPE PLAN - AREA A L1.02 LANDSCAPE PLAN - AREA B L1.03 LANDSCAPE PLAN - AREA C L1.04 LANDSCAPE PLAN - AREAS D, E, F L1.05 ENLARGEMENT LANDSCAPE PLAN L2.00 LANDSCAPE DETAILS, SCHEDULE + NOTES L2.01 BASE BID LANDSCAPE PLAN (FOR REFERENCE) L2.02 BASE BID LANDSCAPE SCHEDULE (FOR REFERENCE) E0.1 ELECTRICAL LEGEND AND ABBREVIATIONS E0.2 OVERALL ELECTRICAL SITE PLAN E0.3A ELECTRICAL SITE PLAN - NEW WORK E0.3B ELECTRICAL SITE PLAN - NEW WORK E0.4 ELECTRICAL SITE PLAN - DEMO E1.1 FIELD #6, #7, #8 & #9 LIGHTING PLAN E1.2 NEW PARKING AREA LIGHTING PLAN E1.3 FIELD 1, 2, 3 & 4 LIGHTING PLAN E2.1 ELECTRICAL FLOOR PLAN - LIGHTING E2.2 ELECTRICAL FLOOR PLAN - POWER/SYSTEMS E4.1 ELECTRICAL RISER DIAGRAMS E5.1 ELECTRICAL SCHEDULES E6.1 ELECTRICAL DETAILS E6.2 ELECTRICAL DETAILS E6.3 ELECTRICAL DETAILS IMPERVIOUS CALCULATIONS POST-DEVELOPMENT: XX AC PRE-DEVELOPMENT: XX AC XX % IMPERVIOUS WATERSHED CAPE FEARRIVER BASIN CAPE FEAR SPACES REQUIRED: N/A SPACES PROVIDED: 418 (8 ACCESSIBLE SPACES) CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R STREAM INFORMATION STREAM INDEX: 18-74-(61) RECEIVING STREAM: NORTHEAST CAPE FEAR RIVER CLASSIFICATION: SC; Sw C1.01 WLM17000-OADM1 - EMD 1" = 100' DEMOLITION PLAN OVERALL NC GRID (NAD83) GRAPHIC SCALE 0 50 100 200 1 inch = 100 ft. CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - O A D M 1 . d w g , 4/ 2 7 / 2 0 2 1 9 : 2 1 : 5 8 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 DEMOLITION LEGEND DEMOLITION NOTES 1.UTILITY STATEMENT: THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE SURVEYOR MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED UNDERGROUND UTILITIES. 2.ALL UTILITIES TO BE RELOCATED SHALL BE COORDINATED WITH THE OWNER AND THE DESIGN TEAM. EXISTING BUILDINGS SHALL REMAIN FUNCTIONING AT ALL TIMES. CONTRACTOR SHALL MAKE ALL EFFORTS TO AVOID AND MINIMIZE UTILITY SHUT DOWN DURING CONSTRUCTION. NEW UTILITIES SHALL BE INSTALLED AND TESTED PRIOR TO EXISTING UTILITY SHUT DOWN. 3.THE CONTRACTOR SHALL FIELD VERIFY AND LOCATE ALL EXISTING UTILITIES ON SITE PRIOR TO DEMOLITION. 4.THE CONTRACTOR SHALL PERFORM DEMOLITION ACTIVITIES AS NOTED AND SHOWN ON THESE PLANS AND SPECIFICATIONS AND AS DIRECTED BY THE OWNER. 5.IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN ANY PERMITS AND PAY FEES REQUIRED FOR DEMOLITION AND HAUL-OFF FROM THE APPROPRIATE AUTHORITIES. THESE FEES ARE TO BE INCLUDED WITH THE BID. THE CONTRACTOR SHALL PREPARE ALL DOCUMENTS AND ACQUIRE APPROPRIATE PERMITS AS REQUIRED PRIOR TO THE COMMENCEMENT OF DEMOLITION. 6.THE DEMOLITION PLAN IS INTENDED TO DEPICT GENERAL DEMOLITION AND UTILITY WORK. IT IS NOT INTENDED TO IDENTIFY EACH ELEMENT OF DEMOLITION OR RELOCATION. CONTRACTOR SHALL COORDINATE WITH THE OWNER AND APPROPRIATE UTILITY COMPANY PRIOR TO WORK. 7.CONTRACTOR SHALL COMPLETELY DEMOLISH ALL EXISTING IMPROVEMENTS NOTED FOR REMOVAL ON THE APPROVED DEMOLITION PLAN. THIS INCLUDES, AS NECESSARY, FOUNDATIONS AND OTHER APPURTENANCES LOCATED ON AND AROUND THE IMPROVEMENTS SUCH AS SIGNS, CURBS, PAVEMENT, SIDEWALKS, LIGHT POLE BASES, HYDRANTS, BOLLARDS, ETC. ALL REMOVED MATERIAL SHALL BE DISPOSED OF OFFSITE IN A LAWFUL MANNER OR RECYCLED. IF POSSIBLE, CONTRACTOR SHALL MAKE EVERY ATTEMPT TO RECYCLE ANY DEBRIS AND RUBBISH THAT IS RECYCLABLE. 8.REMOVE AND/OR PLUG EXISTING UTILITIES AS SHOWN. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING EACH UTILITY COMPANY TO COORDINATE REMOVAL OF ALL UTILITIES AND FOR DETERMINING HORIZONTAL AND VERTICAL LOCATIONS OF UTILITIES PRIOR TO COMMENCING WORK. 9.CONTRACTOR SHALL INSTALL ALL EROSION AND SEDIMENT CONTROL DEVICES AND TREE PROTECTION PRIOR TO BEGINNING DEMOLITION WORK. CONTRACTOR SHALL TAKE EXTRA PRECAUTIONS AND CARE TO PRESERVE TREES DURING CONSTRUCTION. 10.THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL UTILITIES TO REMAIN IN PLACE. 11.ALL EXISTING ITEMS TO REMAIN WHICH ARE DAMAGED DURING CONSTRUCTION SHALL BE RESTORED TO THEIR ORIGINAL CONDITION AT THE SOLE EXPENSE OF THE CONTRACTOR. 12.IF ALTERNATE 4 IS SELECTED, CONTRACTOR SHALL REMOVE THE EXISTING SIGNS 13.CONTRACTOR TO SALVAGE EXISTING TRASH RECEPTACLES AND STOCKPILE FOR REUSE. RELOCATE TO MAINTENANCE YARD PRIOR TO SUBSTANTIAL COMPLETION. 14.CONTRACTOR TO SALVAGE EXISTING WHEEL STOPS FOR REUSE. ANY WHEEL STOPS WITH CRACKS, EXTENSIVE DIRT OR STAINING SHALL BE DEMOLISHED AND REMOVED PER THE SPECIFICATIONS. ALL WHEEL STOPS SLATED FOR REUSE MUST BE APPROVED BY THE ENGINEER. 15.CONTRACTOR MAY STOCKPILE AND REUSE MULCH IF IT MEETS THE PROJECT SPECIFICATIONS. CONTRACTOR MUST REQUEST AND RECEIVE WRITTEN NOTICE FROM THE LANDSCAPE ARCHITECT PRIOR TO ASSUMING MULCH IS ACCEPTABLE FOR REUSE. LANDSCAPE ARCHITECT MAY REQUEST A VISUAL INSPECTION AND RESERVES THE RIGHT TO REJECT THE REQUEST. 16.CONTRACTOR TO FLAG ALL TREES SLATED FOR REMOVAL AND SEEK APPROVAL FROM LANDSCAPE ARCHITECT PRIOR TO DEMOLISHING. TREES INDICATED FOR DEMOLITION ASSOCIATED WITH PARKING LOT RENOVATIONS (ALTERNATE 4) AND WALKING TRAIL (ALTERNATE 1) ARE TO REMAIN FOR BASE BID ONLY, SHOULD THESE ALTERNATES NOT BE SELECTED. EXISTING SITE ENTRANCE P R O P E R T Y L I N E EXISTING PARKING EX. GAZEBO TO REMAIN EXISTING FIELD EXISTING FIELD EXISTING FIELDS EXISTING FIELDS EXISTING PARKING EXISTING PARKING E X I S T I N G P A R K I N G EXISTING PARKING P R O P E R T Y L I N E EXISTING FENCE LINE EX. RESTROOM BUILDING AND SIDEWALK TO BE DEMOLISHED APPROXIMATE EXTENTS OF LANDFILL 20' METHANE VENT CLEAR ZONE EX. GRAVEL PARKING TO BE REMOVED EX. INLETS AND CONC. APRON TO BE DEMOLISHED EX. INLETS AND CONC. APRON TO BE REMOVED EX. GRAVEL DRIVE TO BE REMOVED EX. FENCE TO BE REMOVED EXIST. ABOVE GRADE METHANE VENT TO BE RELOCATED (TYP.) - SEE SHEETS V1.00 TO V6.00 EX. FENCE TO BE REMOVED (2) EX. SIGNS TO BE REMOVED EX. GRAVEL DRIVE TO REMOVED. REFER TO SITE PLANS FOR LOCATIONS EX. GRAVEL TO BE REFRESHED AND LIMITS ADJUSTED - SEE SPECIFICATIONS (ALTERNATE 4) EX. MULCH PILE TO BE REMOVED - SEE NOTE 15 THIS SHEET (2) EX. SEPTIC VALVES TO BE DEMOLISHED EX. SAND PILE TO BE REMOVED (ALTERNATE 1) EX. SEPTIC PUMP AND FORCE MAIN TO BE DEMOLISHED EX. STORAGE CONTAINER TO BE REMOVED EX. INLETS AND CONC. APRON TO BE DEMOLISHED (ALTERNATE 4) EX. IRRIGATION LINES AND VALVES TO BE REMOVED EX. RIPRAP TO BE REMOVED EX. SIGN TO BE REMOVED (ALTERNATE 4) (2) EX. SIGNS TO BE REMOVED. SEE NOTE 12 THIS SHEET. (ALTERNATE 4) EXISTING FENCE LINE APPROX. EXTENTS OF LANDFILL MATERIAL EXISTING SEPTIC SYSTEM TO BE DEMOLISHED OR CAPPED AND ABANDONED IN PLACE. REFER TO SEPTIC DRAWINGS. EX. TREE TO BE REMOVED (TYP.) (ALTERNATE 4) EX. MULCH TO BE ADJUSTED WITH GRAVEL PARKING LIMITS (ALTERNATE 4) EX. GRAVEL TO BE REFRESHED AND LIMITS ADJUSTED (ALTERNATE 4) EX. GRAVEL TO BE REFRESHED AND LIMITS ADJUSTED - SEE SPECIFICATIONS (ALTERNATE 4) EX. MULCH TO BE ADJUSTED WITH GRAVEL PARKING LIMITS (ALTERNATE 4) EX. MULCH TO BE ADJUSTED WITH GRAVEL PARKING LIMITS AND FENCE TO BE REMOVED. (ALTERNATE 4) EX. RIPRAP TO REMAIN APPROX. EXTENTS OF LANDFILL MATERIAL APPROX. EXTENTS OF LANDFILL MATERIAL EX. STORAGE CONTAINER TO BE REMOVED EX. SIGN, ASSOCIATED LANDSCAPING, AND ADJACENT BOLLARDS TO BE REMOVED FIVE (5) EX. BOLLARDS TO BE REMOVED (ALTERNATE 1) EX. POWER POLE TO REMAIN EX. POWER POLE TO REMAIN EX. POWER POLE TO REMAIN EX. POWER POLE TO REMAIN EX. FENCE TO BE REMOVED PORTION OF EXIST. METHANE GAS LINE TO BE REMOVED BELOW PROPOSED RESTROOM BLDG. - ADJACENT METHANE LINE TO BE ADJUSTED APPROPRIATELY - SEE SHEETS V1.00 - V.600 NOTE: CONTRACTOR TO REMOVE AND STORE EXIST. WHEEL STOPS ON SITE FOR REUSE. EXISTING 4-IN WATER LINE TO BE ABANDONED AND CAPPED IN PLACE AT NORTH PROPERTY LINE CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R EXIST. SUBSURFACE METHANE GAS WELL TO BE CAPPED AND ABANDONED BELOW RESTROOM BLDG. - SEE SHEETS V1.00 - V.600 EXTENTS OF EX. SOCCER FIELD TO BE REMOVED NOTE: PRIOR TO CONSTRUCTION, CONTRACTOR SHALL LOCATE EXISTING FORCE MAIN AND SHALL REMOVE, OR CAP AND ADONDON IN PLACE, AS NECESSARY. REFER TO SEPTIC DRAWINGS. EXIST. IRRIGATION LINE (APPROX. LOCATION) EXIST. ABOVE GRADE METHANE VENT TO BE RELOCATED (TYP.) - SEE SHEETS V1.00 TO V6.00 EX. TREE TO BE REMOVED (TYP.) (ALTERNATE 4) EX. TREES TO BE REMOVED EXISTING EDGE OF PAVEMENT EDGE OF EXISTING DRIVE TRANSITION BETWEEN EXIST. ASPHALT DRIVE AND GRAVEL DRIVE EX. FENCE TO BE REMOVED EX. RIPRAP AND PIPE TO BE REMOVED EXIST. ABOVE GRADE METHANE VENT TO BE RELOCATED (TYP.) - SEE SHEETS V1.00 TO V6.00 EX. INLETS AND CONC. APRON TO BE DEMOLISHED (2) EX. SIGNS TO BE REMOVED EX. TREE TO BE REMOVED (TYP.) (ALTERNATE 1) RESTROOM BUILDING SITE LEGEND P R O P E R T Y L I N E FIELD #11 SYNTHETIC FIELD #9 (SEE DETAILED FIELD PLANS) FIELD #6 (SEE DETAILED FIELD PLANS) FIELD #8 (SEE DETAILED FIELD PLANS) NC GRID (NAD83) GRAPHIC SCALE 0 100 200 400 1 inch = 200 ft.C1.02 WLM17000-OAS1 - GLJ 1" = 150' PLAN CONTEXT FIELD #7 (SEE DETAILED FIELD PLANS) SEE SHEET C2.00 FOR OVERALL SITE PLAN APPROXIMATE LIMITS OF LANDFILL CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - C o n t e x t . d w g , 4/ 2 7 / 2 0 2 1 9 : 2 0 : 0 2 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 RENOVATED FIELD #4 SUTTON STEAM P L A N T R O A D (VARIABLE WIDTH P U B L I C R / W ) EXISTING FIELD #2 EXISTING FIELD #5 EXISTING FIELD #10 EXISTING FIELD #3 EXISTING FIELD #1 WETLAND (TYP.) WETLAND (TYP.) WETLAND (TYP.) APPROX. EXTENT OF ACCESS ROAD ACCESS EASEMENT R A I L R O A D ( V A R I A B L E W I D T H R / W ) NOTES 1.ALL BASE DATA OUTSIDE OF THE PROPERTY LIMITS HAS BEEN PROVIDED BY ATLANTIC COAST SURVEY AND DATED MARCH 25, 2021. 2.ALTERNATES INDICATE PLAN ELEMENTS THAN MAY NOT BE CONSTRUCTED IF BUDGET DOES NOT ALLOW. ENGINEER SHALL SUBMIT A "RELEASED FOR CONSTRUCTION" PACKAGE FOR THE COUNTY'S RECORDS ONCE THE FINAL PROJECT SCOPE IS FINALIZED. 210.0'23.0'15 . 0 ' 23.0'22.5'22.5'22.5'22.5'22.5'22.5'26.0' 45.0' NC GRID (NAD83)C2.00 WLM17000-OAS1 - EMD 1" = 100' SITE PLAN OVERALL CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - O A S 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 1 5 : 4 5 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 DESCRIPTION ALTERNATES STONE DUST WALKING TRAIL INSTALL GRAVEL WALKING TRAIL PER SITE PLAN AND DETAILS. COMPACT PER GEOTECH. INSTALL ASSOCIATED SITE FURNISHINGS (BENCHES, WAYFINDING SIGNAGE AND TRASH / RECYCLING RECEPTACLES) SHALL BE PROVIDED. PLAYGROUND PROVIDE INSTALLATION OF EQUIPMENT, POURED-IN-PLACE SAFETY SURFACE, PERIMETER FENCING (ALTERNATE 3A). SEE REFERENCE MATERIAL. INCLUDE ADDITIONAL SWING SET. INSTALL ASSOCIATED SITE FURNISHINGS (BENCHES, PLAYGROUND RULES, WAYFINDING SIGNAGE AND TRASH / RECYCLING RECEPTACLES) SHALL BE PROVIDED. LANDSCAPE IMPROVEMENTS AND GRAVEL REFRESH WITHIN LIMITS OF EXISTING PARKING LOTS, REPAIR SOFT AREAS IDENTIFIED BY THE GEOTECH AND CONTRACTOR, PLACE 2" ABC AND COMPACT PER PROJECT SPECIFICATIONS. ADD ACCESSIBLE PARKING SPACES (1 VAN, 1 CAR) TO EACH EXISTING PARKING LOT WITH PAVED ACCESS SIDEWALK TO NEAREST FIELDS. REMOVE DELETERIOUS PLANT MATERIAL AND REPLACE WITH PLANT MATERIAL PER LANDSCAPE PLANS WITHIN LIMITS OF EXISTING PARKING AREAS. ATHLETIC LIGHTS AT FIELDS 6 + 7 (X6) ATHLETIC LIGHTS AT FIELDS 8 + 9 (X6) NATURAL FIELDS + FIELD UNDERDRAINS PROVIDE NATURAL GRASS FIELD UNDERDRAINS FOR ALL FOUR FIELDS AS SHOWN PER PLAN AND SPECIFICATIONS. KEY MAP N.T.S. C2.01, C2.10 C2.03, C2.12 C2.04 C2.02, C2.11 1 3 8 9 10 4 ALTERNATEALT. # PROVIDE 2 POST, EACH WITH A SINGLE LIGHT FIXTURE, AT WESTERN EDGE OF EXISTING FIELD #4 11 ATHLETIC LIGHTS AT FIELDS 4 (X2) EXISTING SITE ENTRANCE RESTROOM BUILDING EXISTING GAZEBO FOOD TRUCK PARKING ADA PARKING EXISTING EDGE OF PAVEMENT GRAVEL PARKING LOT 10' CONCRETE SIDEWALK WALKING TRAIL (ALTERNATE 1) PLAYGROUND AND PATH CONNECTION (ALTERNATE 3) 20' METHANE VENT CLEAR ZONE PLAYING FIELD PERIMETER FENCE WHEELSTOP (TYP.) LEVEL SPREADER LEVEL SPREADER SITE LEGEND PR O P E R T Y L I N E EXISTING FIELD #10 EXISTING FIELD #5 RENOVATED FIELD #4 FIELD #11 SYNTHETIC (SEE DETAILED FIELD PLANS) EXISTING FIELD #2 FIELD #9 (SEE DETAILED FIELD PLANS) FIELD #6 (SEE DETAILED FIELD PLANS) FIELD #8 (SEE DETAILED FIELD PLANS) P R O P E R T Y L I N E RENOVATED PARKING (ALTERNATE 4) 10 S P A C E S 10 S P A C E S 10 S P A C E S 16 S P A C E S 10 S P A C E S 12 S P A C E S 12 SPACES 8 S P A C E S 8 S P A C E S 8 S P A C E S 8 S P A C E S 8 S P A C E S 8 S P A C E S 17 SPACES 17 SPACES 23 SPACES 21 SPACES 21 SPACES 23 SPACES 23 SPACES 27 SPACES27 SPACES 23 SPACES 4 SPACES 21 SPACES 9 S P A C E S 9 S P A C E S 11 S P A C E S 13 S P A C E S GENERAL SITE NOTES - APPLIES TO SHEETS C2.00, C2.01, C2.02,C2.03, C2.04 1.THE CONTRACTOR SHALL WORK CLOSELY WITH THE OWNER'S REP. AND/OR LANDSCAPE ARCHITECT AND NOTIFY OWNER'S REPRESENTATIVE AND/OR LANDSCAPE ARCHITECT AS ADDITIONAL INFORMATION IS NEEDED TO PROPERLY CONSTRUCT/INSTALL/BUILD ELEMENTS DEPICTED HEREIN. 2.THE CONTRACTOR SHALL PERFORM HIS/HER OWN INVESTIGATIONS TO THE EXTENT NECESSARY TO DETERMINE EFFECTS OF SUB-SURFACE CONDITIONS ON WORK AND SHALL BID AND CONSTRUCT WORK IN ACCORDANCE WITH FINDINGS. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL EXISTING UNDERGROUND UTILITIES PRIOR TO BEGINNING CONSTRUCTION ACTIVITIES AND FOR AVOIDING ALL CONFLICTS WITH SAME. ANY DAMAGE TO EXISTING UTILITIES SHALL BE REPAIRED AT THE EXPENSE OF THE CONTRACTOR. 4.CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES AND UNUSUAL CONDITIONS TO OWNER'S REP. AND/OR LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION. 5.ALL DISTURBED AREAS AND PROPOSED EARTH GRADING NOT TO BE COVERED BY OTHER SURFACES SHALL BE STABILIZED BY SEEDING, FERTILIZING, MULCHING, AND WATERING AS REQUIRED TO OBTAIN AN ACCEPTABLE GROUND COVER, UNLESS SPECIFIED OTHERWISE. ALL AREAS THAT ARE DISTURBED BY CONSTRUCTION INSIDE OR OUTSIDE THE LIMITS OF WORK SHALL BE REPAIRED, GRADED, AND GRASSED AT THE CONTRACTOR'S EXPENSE. 6.SEE CIVIL DRAWINGS FOR ADDITIONAL GRADING AND DRAINAGE INFORMATION. 7.CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING PROPER DRAINAGE OF ANY AND ALL AREAS WHICH ARE FIELD ADJUSTED DURING CONSTRUCTION. 8.CONTRACTOR SHALL RESTORE DAMAGED FINISHES AND REPLACE DAMAGED OR DEFECTIVE BRICK PAVERS OR CONCRETE. 9.CONTRACTOR SHALL STAKE ALL WALKS, HARDSCAPE AND OTHER PAVED AREAS TO BE COMPLETED AND OBTAIN APPROVAL FROM OWNER'S REP. AND/OR LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE RESOLVED PRIOR TO CONSTRUCTION. ANY WORK PERFORMED WITHOUT APPROVAL IS AT RISK FOR REPLACEMENT BY THE CONTRACTOR. 10.ALL FIELD ADJUSTMENTS SHALL RECEIVE APPROVAL FROM OWNER'S REP. PRIOR TO CONSTRUCTION. 11.CONSTRUCT EXPANSION JOINTS WHERE WALKS MEET CURBS, STEPS, WALLS, FIXED SLABS, OR VERTICAL STRUCTURES. 12.TEMPORARY EROSION & SEDIMENT CONTROLS (SILT FENCES, ETC.) SHALL BE INSTALLED AT INLETS, PIPES, AND LIMITS OF WORK AREAS WHERE SURFACE RUN-OFF OCCURS UNTIL SOIL STABILIZATION IS COMPLETE. SEE CIVIL DRAWINGS FOR SEDIMENTATION AND EROSION CONTROL INFORMATION. 13.SEE ARCHITECTURAL PLANS FOR BUILDING INFORMATION. 14.CONTRACTOR SHALL MAINTAIN ALL GRASSED AREAS, INCLUDING REPAIR OF EROSION AREAS UNTIL GRASS HAS REACHED LEVEL OF FINAL ACCEPTANCE. 15.ALL CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH CONTRACT DOCUMENTS AND ALL LOCAL, STATE, AND FEDERAL AGENCIES AND REGULATIONS. 16.CONTRACTOR SHALL PROTECT THE PUBLIC FROM CONSTRUCTION AREAS AND ASSOCIATED ACTIVITY DURING CONSTRUCTION. 17.DIGITAL BASE FILE MAY BE MADE AVAILABLE FOR USE IN FIELD LOCATION OF ELEMENTS AND SITE FEATURES. ANY HARDCOPY INFORMATION THAT CONFLICTS SHALL BE BROUGHT TO OWNER'S REP AND/OR LANDSCAPE ARCHITECT'S ATTENTION. 18.CONTRACTOR SHALL COORDINATE CONDUIT LOCATIONS (I.E. IRRIGATION, ELECTRICAL, NATURAL GAS ETC.) PRIOR TO CONCRETE INSTALLATION. 19.SEE SPECIFICATIONS FOR GRAVEL REFRESH. 20.ALL FENCE POST AND LIGHT POST FOOTINGS, POLES, ETC. SHALL BE COORDINATED WITH ALL EXISTING AND PROPOSED SITE ELEMENTS INCLUDING THE METHANE VENT LINES. CONTRACTOR IS RESPONSIBLE FOR ONSITE COORDINATION AND NOTIFYING OWNER AND OWNER'S REPRESENTATIVE FOR ANY CHANGES. 21.CONTRACTOR SHALL INCLUDE THE COST OF PROCUREMENT AND INSTALLATION OF ATHLETIC LIGHT FOUNDATIONS. PROCUREMENT AND INSTALLATION OF THE POLES AND FIXTURES WILL BE PROVIDED BY THE OWNER. CONTRACTOR SHALL COORDINATE WITH THE OWNER AND OWNER'S REPRESENTATIVE FOR CONSTRUCTION SEQUENCING RELATED TO INSTALLATION OF THE ATHLETIC POLES AND FIXTURES. 22.PER THE TIA APPROVAL LETTER DATED APRIL 29, 2020, THE FOLLOWING IMPROVEMENTS SHALL BE INSTALLED PRIOR TO ANY CERTIFICATE OF OCCUPANCY: 22.1.US 321 AT SUTTON STEAM PLAN ROAD 22.1.1.RESTRIPE THE EASTBOUND APPROACH TO PROVIDE A CONTINUOUS RIGHT TURN LANE AND LEFT TURN LANE WITH AVAILABLE STORAGE WITH EXISTING PAVEMENT. WALKING TRAIL (ALTERNATE 1) AREA D - SEE SHEET C2.04 ACCESS PATH TO SYNTH. TURF FIELD WHEELSTOP (TYP.) 10' CONCRETE SIDEWALK ENTRANCE PLAZA CONCRETE BENCH PAD (ALTERNATE 1) FIELD #7 (SEE DETAILED FIELD PLANS) RENOVATED PARKING (ALTERNATE 4) AREA B - SEE SHEET C2.02 AREA C - SEE SHEET C2.03 FRAME COLOR: TEXTURED PEWTER SLAT COLOR: MAHOGANY RECYCLED PLASTIC FRAME COLOR: TEXTURED PEWTER SLAT COLOR: MAHOGANY RECYCLED PLASTIC BY OWNERTEAM BENCH BY OWNERBY OWNER APPROXIMATE LIMITS OF LANDFILL APPROXIMATE LIMITS OF LANDFILL APPROXIMATE LIMITS OF LANDFILL PROCUREMENT RENOVATED PARKING 10 SP A C E S 2 SP A C E S PROPERTY LINE WHEELSTOP (TYP.) EXISTING RIP RAP ACCESS TO FIELD GATE PRIMARY ENTRANCE MONUMENT PRODUCT PRODUCT DESCRIPTION FRAME COLOR: TEXTURED PEWTER SLAT COLOR: MAHOGANY RECYCLED PLASTIC FURNISHING SURFACE MOUNTED BENCH BY OWNER RECYCLING RECEPTACLE BY OWNER TRASH RECEPTACLE BY OWNER OVERALL FURNISHING SCHEDULE BEACON HILL 6' BY ANOVA OR APPROVED EQUAL MADISON BY ANOVA OR APPROVED EQUAL MADISON (RECYCLE TOP) BY ANOVA OR APPROVED EQUAL PLANTER BOX BY OWNER CUBE PLANTER BY YARDART OR APPROVED EQUAL 36"X36" ALUMINUM COLOR: OXIDIZED ZINC SHED TO REMAIN MAINTENANCE BLDG. AND FENCE ACCESS TO FIELD GATE EXISTING FIELD #3 EXISTING FIELD #1 APPROXIMATE EXTENTS OF ALTERNATE 4 APPROXIMATE EXTENTS OF ALTERNATE 4 WALKING TRAIL (ALTERNATE 1)PO L E M O U N T E D A T H L E T I C LI G H T F I X T U R E ( A L T E R N A T E 9 ) POLE MOUNTED ATHLETIC LIGHT FIXTURE (ALTERNATE 9) PO L E M O U N T E D A T H L E T I C LI G H T F I X T U R E ( A L T E R N A T E 8 ) PO L E M O U N T E D A T H L E T I C LI G H T F I X T U R E ( A L T E R N A T E 8 ) PO L E M O U N T E D A T H L E T I C LI G H T F I X T U R E ( A L T E R N A T E 9 ) POLE MOUNTED ATHLETIC LIGHT FIXTURE (ALTERNATE 8) ACCESS TO FIELD GATE (ALTERNATE 1) ACCESS TO FIELD GATE (ALTERNATE 1) FIELD LIGHTS (BASE BID) WALKING TRAIL (ALTERNATE 1) POLE MOUNTED ATHLETIC LIGHT FIXTURE (BASE BID) FIELD LIGHT (BASE BID) POLE MOUNTED ATHLETIC LIGHT FIXTURE (BASE BID) CONCRETE SIDEWALK (ALTERNATE 1) FIELD LIGHT (BASE BID) POLE MOUNTED ATHLETIC LIGHT FIXTURE (BASE BID) POLE MOUNTED ATHLETIC LIGHT FIXTURE (BASE BID) POLE MOUNTED ATHLETIC LIGHT FIXTURE (BASE BID) ADA PARKING (ALTERNATE 4) ADA PARKING (ALTERNATE 4) DUMPSTER PAD AND FENCE ENCLOSURE TIE IN FLUSH WITH EXISTING ASPHALT ENTRY DRIVE POLE MOUNTED ATHLETIC LIGHT FIXTURE (ALTERNATE 11) POLE MOUNTED ATHLETIC LIGHT FIXTURE (ALTERNATE 11) 10 INSTALLATION 9 10 10 8 BASE QTY.ALT. QTY. 10 4 4 4 8 0 5 6 6 0 ADA PARKING (ALTERNATE 4) AREA A - SEE SHEET C2.01 APPROXIMATE EXTENTS OF ALTERNATE 3 CONCRETE BENCH PAD (ALTERNATE 1) APPROXIMATE LOCATION OF CHAIN LINK FENCE INSTALLED BY OWNER (N.I.C.) ACCESS TO FIELD GATE (ALTERNATE 1) CONCRETE TRASH RECEPTACLE (ALTERNATE 1) 4'X8' CONCRETE TRASH RECEPTACLE PAD (ALTERNATE 1) 4'X8' CONCRETE TRASH RECEPTACLE PAD (ALTERNATE 1) ACCESS TO FIELD GATE (ALTERNATE 1) ACCESS TO FIELD GATE (ALTERNATE 1) ACCESS TO FIELD GATE (ALTERNATE 1) ACCESS TO FIELD GATE (ALTERNATE 1) ACCESS TO FIELD GATE (ALTERNATE 1) ACCESS TO FIELD GATE (ALTERNATE 1) SEE NOTE 21, THIS SHEET. SEE ELECTRICAL DRAWINGS FOR ATHLETIC FIELD LIGHTING GRAPHIC SCALE 0 50 100 200 1 inch = 100 ft. NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft.C2.01 WLM17000-S1 - GLJ 1" = 40' AREA A SITE PLAN MATCHLINE - SEE SHEET C2.02 CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - S 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 1 6 : 1 2 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 MATCHLINE - SEE SHEET C2.04 KEY MAP N.T.S. C2.01 C2.03 C2.04 C2.02 LIMITS OF GRAVEL REFRESH (BASE BID). MEET ASPHALT ENTRANCE DRIVE, FLUSH. R42' EXISTING FIELD #5 EX. GRAVEL TO BE REFRESHED AND LIMITS ADJUSTED 20' 20' METHANE VENT CLEAR ZONE (TYP.) GENERAL SITE NOTES 1.SEE SHEET C2.00 FOR GENERAL SITE NOTES 2.GRAVEL REFRESH SHALL INCLUDE ADDITION OF 2" ABC PER NCDOT STANDARDS TO EXISTING GRAVEL. CONTRACTOR ENSURE POSITIVE DRAINAGE ACROSS SITE. POLE MOUNTED ATHLETIC LIGHT FIXTURE (BASE BID) POLE MOUNTED ATHLETIC LIGHT FIXTURE (BASE BID) SITE LEGEND DETAIL KEY SCHEDULE C8.00 CONCRETE PAVING (PEDESTRIAN)01 C8.00 CONCRETE PAVING (HEAVY DUTY)02 C8.00 GRAVEL PAVING03 C8.00 ACCESSIBLE PARKING SPACE04 C8.00 WHEEL STOP05 L3.01 PRIMARY ENTRANCE MONUMENT07 SFD1.01 6' CHAIN LINK FENCE11 SFD1.01 CHAIN LINK FENCE DOUBLE GATE13 C8.00 WALKING TRAIL19C8.02 DUMPSTER ENCLOSURE09 C8.02 SAFETY BOLLARD15 C8.02 COLLABSIBLE BOLLARD16 C8.01 TIMBER EDGING08 SFD1.01 CHAIN LINK FENCE SINGLE GATE14 C8.02 HEAVY DUTY BOLLARD17 C8.01 CLF DOUBLE GATE W/ PRIVACY SLATS18 SFD1.01 FENCE WITH NETTING12 C8.00 CONCRETE STEPS WITH HANDRAILS06 C8.01 CHAIN LINK FENCE W/ PRIVACY SLATS10 C8.02 ADA CROSSWALK20 C8.02 ADA PLAYGROUND RAMP + EWF SURFACE21 C8.02 PLAYGROUND FENCE22 C8.02 PLAYGROUND GATE23 07 EXISTING BOLLARDS (TYP.) LIGHTING PANEL AND CONTROLS PARKING LOT LIGHTS. SEE ELECTRICAL DRAWINGS. PARKING LOT LIGHTS. SEE ELECTRICAL DRAWINGS. GATE ACCESS PATH 5' 12' 210'210'210'210' 22.5'22.5'22.5'22.5'22.5'22.5' 23'20' 54 ' 25 2 ' 54 ' 15' CLR 15' CLR 20' CLR20' CLR POLE MOUNTED ATHLETIC LIGHT FIXTURE (BASE BID) POLE MOUNTED ATHLETIC LIGHT FIXTURE (BASE BID) EXISTING FIELD #1EXISTING FIELD #3 20' METHANE VENT CLEAR ZONE EXISTING FIELD #2 18 11 PARKING LOT LIGHTS. SEE ELECTRICAL DRAWINGS. EX. GRAVEL TO BE REFRESHED AND LIMITS ADJUSTED (BASE BID) ADJUSTED EDGE OF GRAVEL DRIVE CHAINLINK FENCE BY OWNER. N.I.C. TEAM BENCH SURFACE MOUNTED BENCH RECYCLING RECEPTACLE TRASH RECEPTACLE PLANTER BOX FURNISHING LEGEND NOTE: SEE C2.00 FOR FURNISHING SCHEDULE R200' R15 ' R1 5 ' 5' 03 NO-PARKING SIGN. SEE SIGN KEY NO-PARKING SIGN. SEE SIGN KEY NO-PARKING SIGN. SEE SIGN KEY NO-PARKING SIGN. SEE SIGN KEY NO-PARKING SIGN. SEE SIGN KEY NO-PARKING SIGN. SEE SIGN KEY NO-PARKING SIGN. SEE SIGN KEY NO-PARKING SIGN. SEE SIGN KEY LIGHT POLES TO BE OFFSET XX' TO THE OUTSIDE OF THE FENCE LINE AS SHOWN. LIGHT POLES TO BE OFFSET XX' TO THE OUTSIDE OF THE FENCE LINE AS SHOWN. R15' SIGN MUTCD SIGN KEY HANDICAP PARKING R7-8 NO-PARKING SIGN R-7a CHAINLINK FENCE BY OWNER. N.I.C. EXISTING FIELD #5 EXISTING BOLLARDS (TYP.) PARKING LOT LIGHTS. SEE ELECTRICAL DRAWINGS. FIELD #10 SYNTHETIC TURF FIELD (BASE BID) 20' METHANE VENT CLEAR ZONE PROPOSED WALKING TRAIL (ALTERNATE 1) CONCRETE BENCH PAD (ALTERNATE 1) PROPOSED WALKING TRAIL (ALTERNATE 1) EXTENTS OF ALTERNATE 4 EX. GRAVEL TO BE REFRESHED AND LIMITS ADJUSTED 01 SIDEWALK (ALTERNATE 1)05 19 19 10' EX. GRAVEL TO BE REFRESHED AND LIMITS ADJUSTED (ALTERNATE 4) SEE ENLARGEMENT, SHEET C2.13 20 RENOVATED FIELD #4 (BASE BID) SEE ENLARGEMENT, SHEET C2.13 16 GATE ACCESS PATH 19 05 15' 18' R5' 14' 9' 24' 9' 9' 10 ' 1 0 ' 10' 18'24'18'18'24'18' 9' 18 ' R6'R65 ' 18 ' R5' R16' 24 ' 18 ' R5' 14' 27' R15.5 22 ' 36' 12' 9' 18 ' R25' R5' 24' 19'14' R20' R20' R85' R40' R 2 0 ' 5' R3' 24' 18.5' C2.02 WLM17000-S1 - GLJ 1" = 40' NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. AREA B SITE PLAN MATCHLINE - SEE SHEET C2.03 CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - S 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 1 6 : 2 1 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 MATCHLINE - SEE SHEET C2.03 MA T C H L I N E - S E E S H E E T C 2 . 0 4 KEY MAP N.T.S. C2.01 C2.03 C2.04 C2.02 18 ' 24 ' 18 ' 18 ' 24 ' 18 ' 23 SPACES 23 SPACES 27 SPACES 21 SPACES 27 SPACES 21 SPACES R10' 20 . 1 ' 129.8' 20' R42' 10' 44 . 5 ' R5' R12' 20' 20 ' 20 ' 16 ' 60 ' 16 ' 60 ' 10 ' 24 ' 24 ' 10' 207' 258.6' 34'189'189' R40' R42' R12' R5' 20' 20' 20' 246.6'246.6' 10 ' 34' R12' R12' R5' 20' METHANE VENT CLEAR ZONE 20' R 4 0 ' PARKING LOT LIGHTS. SEE ELECTRICAL DRAWINGS. PARKING LOT LIGHTS. SEE ELECTRICAL DRAWINGS. APPROX. LIMITS OF LANDFILL MATERIAL 8'X6' CONCRETE PAD 15 ' R 5 5 ' FIELD #7 (SEE DETAILED FIELD PLANS) FIELD #9 (SEE DETAILED FIELD PLANS) SITE LEGEND DETAIL KEY SCHEDULE C8.00 CONCRETE PAVING (PEDESTRIAN)01 C8.00 CONCRETE PAVING (HEAVY DUTY)02 C8.00 GRAVEL PAVING03 C8.00 ACCESSIBLE PARKING SPACE04 C8.00 WHEEL STOP05 L3.01 PRIMARY ENTRANCE MONUMENT07 SFD1.01 6' CHAIN LINK FENCE11 SFD1.01 CHAIN LINK FENCE DOUBLE GATE13 C8.00 WALKING TRAIL19C8.02 DUMPSTER ENCLOSURE09 C8.02 SAFETY BOLLARD15 C8.02 COLLABSIBLE BOLLARD16 C8.01 TIMBER EDGING08 SFD1.01 CHAIN LINK FENCE SINGLE GATE14 C8.02 HEAVY DUTY BOLLARD17 C8.01 CLF DOUBLE GATE W/ PRIVACY SLATS18 SFD1.01 FENCE WITH NETTING12 C8.00 CONCRETE STEPS WITH HANDRAILS06 C8.01 CHAIN LINK FENCE W/ PRIVACY SLATS10 C8.02 ADA CROSSWALK20 C8.02 ADA PLAYGROUND RAMP + EWF SURFACE21 C8.02 PLAYGROUND FENCE22 C8.02 PLAYGROUND GATE23 04 016' 02 01 03 01 11 11'5'8.5'10'15'30' 15 ' 10 16 207'23 SPACES (9' X 18' TYP.) 23 SPACES 15' 15 ' SHED TO REMAIN ELECTRICAL TRANSFORMERS AND PANEL PARKING LOT LIGHTS. SEE ELECTRICAL DRAWINGS. PARKING LOT LIGHTS. SEE ELECTRICAL DRAWINGS. 13 118' 70 ' 70 ' R10' R20' 5' 8' GATE ACCESS PATH 15 ' 20' 10' 10 ' FOOD TRUCK PARKING ELECTRICAL TRANSFORMERS AND PANEL 14 11 11 14 12 12 17 06 10 ' EXISTING FIELD #5 EXISTING FIELD #10 20 01 20 01 20 19.2'5' TEAM BENCH SURFACE MOUNTED BENCH RECYCLING RECEPTACLE TRASH RECEPTACLE PLANTER BOX FURNISHING LEGEND NOTE: SEE C2.00 FOR FURNISHING SCHEDULE 10 ELECTRIC VEHICLE CHARGING STATIONS. SEE ELECTRICAL DRAWINGS 52 ' 19 ' R8' GENERAL SITE NOTES 1.SEE SHEET C2.00 FOR GENERAL SITE NOTES 2.GRAVEL REFRESH SHALL INCLUDE ADDITION OF 2" ABC PER NCDOT STANDARDS TO EXISTING GRAVEL. CONTRACTOR ENSURE POSITIVE DRAINAGE ACROSS SITE. METHANE GAS RACK 12 18 LIGHT BOLLARDS. SEE ELECTRICAL DRAWINGS FOR LOCATIONS AND FIXTURE INFORMATION NO-PARKING SIGN. SEE SIGN KEY NO-PARKING SIGN. SEE SIGN KEY NO-PARKING SIGN. SEE SIGN KEY NO-PARKING SIGN. SEE SIGN KEY 17 09 HANDICAP PARKING SIGN NO-PARKING SIGN. SEE SIGN KEY NO-PARKING SIGN. SEE SIGN KEY 4'X8' CONCRETE BENCH PAD 4'X8' TRASH RECEPTACLE PAD 16 SIGN MUTCD SIGN KEY HANDICAP PARKING R7-8 NO-PARKING SIGN R-7a MATCHLINE - SEE SHEET C2.10 RESTROOM BUILDING ±2,600 SF (BASE BID) SEE ARCH. DRAWINGS 10 ' WOODEN RAMPS ENTRY RAMPS (BASE BID) SEE ARCH. DRAWINGS ELECTRICAL TRANSFORMERS AND PANEL MAINTENANCE BUILDING (BASE BID) ±400 SF. SEE ARCH. DRAWINGS FIELD #11 SYNTHETIC TURF FIELD (BASE BID) 5' 15 ' POLE MOUNTED ATHLETIC LIGHTING FIXTURE (ALTERNATE 8)10' 10 ' 10' WALKING TRAIL (ALTERNATE 1) 4'X8' CONCRETE BENCH PAD WALKING TRAIL (ALTENATE 1) POLE MOUNTED ATHLETIC LIGHTING FIXTURE (ALTERNATE 9) WALKING TRAIL (ALTERNATE 1) 90 ' R25' R3' R6' 18' R5' 8 1 ' 10 5 . 5 ' PLAYGROUND (ALTERNATE 3) POLE MOUNTED ATHLETIC LIGHTING FIXTURE (ALTERNATE 8) POLE MOUNTED ATHLETIC LIGHTING FIXTURE (ALTERNATE 9) GATE ACCESS PATH 5' GATE ACCESS PATH 01 22 R95' 10' 05 05 EX. GRAVEL TO BE REFRESHED AND LIMITS ADJUSTED (ALTERNATE 4) EX. GRAVEL TO BE REFRESHED AND LIMITS ADJUSTED (ALTERNATE 4) 19 19 ELECTRICAL TRANSFORMERS AND PANEL (BASE BID) ELECTRICAL TRANSFORMERS AND PANEL (BASE BID) EXTENTS OF ALTERNATE 3 EXTENTS OF ALTERNATE 4 EXTENTS OF ALTERNATE 4 EXISTING FIELD #5 EXISTING FIELD #10 SEE ENLARGEMENT, SHEET C2.04 16 02 19 WALKING TRAIL (ALTERNATE 1) 14 42 . 2 ' 15' 24' GRAVEL (ALTERNATE 1) PEDESTRIAN RATED CONCRETE (ALTERNATE 3) 23 08 21 PLAYGROUND FENCE AND GATES (ALTERNATE 3A) R10' R 1 2 0 ' 4'X8' CONCRETE TRASH RECEPTACLE PAD R195' R195' R95 ' R55' 10' 18.2' 8' 6' R50' 8' 6' 18' 24' 18' 4'X8' CONCRETE BENCH PAD 4'X8' CONCRETE BENCH PAD C2.03 WLM17000-S1 - EMD 1" = 40' NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. AREA C SITE PLAN MATCHLINE - SEE SHEET C2.02 CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - S 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 1 6 : 4 1 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 MATCHLINE - SEE SHEET C2.02 12 KEY MAP N.T.S. C2.01 C2.03 C2.04 C2.02 12 PROPERTY LINE APPROX. LIMITS OF LANDFILL MATERIAL SITE LEGEND DETAIL KEY SCHEDULE C8.00 CONCRETE PAVING (PEDESTRIAN)01 C8.00 CONCRETE PAVING (HEAVY DUTY)02 C8.00 GRAVEL PAVING03 C8.00 ACCESSIBLE PARKING SPACE04 C8.00 WHEEL STOP05 L3.01 PRIMARY ENTRANCE MONUMENT07 SFD1.01 6' CHAIN LINK FENCE11 SFD1.01 CHAIN LINK FENCE DOUBLE GATE13 C8.00 WALKING TRAIL19C8.02 DUMPSTER ENCLOSURE09 C8.02 SAFETY BOLLARD15 C8.02 COLLABSIBLE BOLLARD16 C8.01 TIMBER EDGING08 SFD1.01 CHAIN LINK FENCE SINGLE GATE14 C8.02 HEAVY DUTY BOLLARD17 C8.01 CLF DOUBLE GATE W/ PRIVACY SLATS18 SFD1.01 FENCE WITH NETTING12 C8.00 CONCRETE STEPS WITH HANDRAILS06 C8.01 CHAIN LINK FENCE W/ PRIVACY SLATS10 C8.02 ADA CROSSWALK20 C8.02 ADA PLAYGROUND RAMP + EWF SURFACE21 C8.02 PLAYGROUND FENCE22 C8.02 PLAYGROUND GATE23 11 FIELD #6 (SEE DETAILED FIELD PLANS) FIELD #8 (SEE DETAILED FIELD PLANS) FIELD #7 (SEE DETAILED FIELD PLANS) FIELD #9 (SEE DETAILED FIELD PLANS) 13 FIELD #6 (BASE BID) (SEE DETAILED FIELD PLANS) FIELD #8 (BASE BID) (SEE DETAILED FIELD PLANS) FIELD #7 (BASE BID) (SEE DETAILED FIELD PLANS) FIELD #9 (SEE DETAILED FIELD PLANS) 08 14 18 21 TEAM BENCH SURFACE MOUNTED BENCH RECYCLING RECEPTACLE TRASH RECEPTACLE PLANTER BOX FURNISHING LEGEND NOTE: SEE C2.00 FOR FURNISHING SCHEDULE 12 14 GENERAL SITE NOTES 1.SEE SHEET C2.00 FOR GENERAL SITE NOTES 2.GRAVEL REFRESH SHALL INCLUDE ADDITION OF 2" ABC PER NCDOT STANDARDS TO EXISTING GRAVEL. CONTRACTOR ENSURE POSITIVE DRAINAGE ACROSS SITE. SIGN MUTCD SIGN KEY HANDICAP PARKING R7-8 NO-PARKING SIGN R-7a FIELD #6 (BASE BID)FIELD #8 (BASE BID) PROPOSED LEVEL SPREADER (BASE BID) PROPOSED LEVEL SPREADER (BASE BID) WALKING TRAIL (ALTERNATE 1) FIELD #7 (BASE BID) (SEE DETAILED FIELD PLANS) FIELD #9 (BASE BID) (SEE DETAILED FIELD PLANS) POLE MOUNTED ATHLETIC LIGHTING FIXTURE (ALTERNATE 8) POLE MOUNTED ATHLETIC LIGHTING FIXTURE (ALTERNATE 9) POLE MOUNTED ATHLETIC LIGHTING FIXTURE (ALTERNATE 8) POLE MOUNTED ATHLETIC LIGHTING FIXTURE (ALTERNATE 9) POLE MOUNTED ATHLETIC LIGHTING FIXTURE (ALTERNATE 8) POLE MOUNTED ATHLETIC LIGHTING FIXTURE (ALTERNATE 9) POLE MOUNTED ATHLETIC LIGHTING FIXTURE (ALTERNATE 8) POLE MOUNTED ATHLETIC LIGHTING FIXTURE (ALTERNATE 9) 19 19 19 10' R95 ' 5' WALKING TRAIL (ALTERNATE 1) 4'X8' CONCRETE BENCH PAD (ALTERNATE 1) 4'X8' TRASH RECEPTACLE PAD (ALTERNATE 1) 4'X8' TRASH RECEPTACLE PAD (ALTERNATE 1) 4'X8' TRASH RECEPTACLE PAD (ALTERNATE 1) C2.04 WLM17000-S1 - EMD SEE DRAWINGS NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. AREA D SITE PLAN SITE LEGEND DETAIL KEY SCHEDULE C8.00 CONCRETE PAVING (PEDESTRIAN)01 C8.00 CONCRETE PAVING (HEAVY DUTY)02 C8.00 GRAVEL PAVING03 C8.00 ACCESSIBLE PARKING SPACE04 C8.00 WHEEL STOP05 L3.01 PRIMARY ENTRANCE MONUMENT07 SFD1.01 6' CHAIN LINK FENCE11 SFD1.01 CHAIN LINK FENCE DOUBLE GATE13 C8.00 WALKING TRAIL19C8.02 DUMPSTER ENCLOSURE09 C8.02 SAFETY BOLLARD15 C8.02 COLLABSIBLE BOLLARD16 C8.01 TIMBER EDGING08 SFD1.01 CHAIN LINK FENCE SINGLE GATE14 C8.02 HEAVY DUTY BOLLARD17 C8.01 CLF DOUBLE GATE W/ PRIVACY SLATS18 SFD1.01 FENCE WITH NETTING12 C8.00 CONCRETE STEPS WITH HANDRAILS06 C8.01 CHAIN LINK FENCE W/ PRIVACY SLATS10 C8.02 ADA CROSSWALK20 C8.02 ADA PLAYGROUND RAMP + EWF SURFACE21 C8.02 PLAYGROUND FENCE22 C8.02 PLAYGROUND GATE23 CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - S 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 1 7 : 0 1 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 MATCHLINE - SEE SHEET C2.01 MA T C H L I N E - S E E S H E E T C 2 . 0 2 AREA D GENERAL SITE NOTES 1.SEE SHEET C2.00 FOR GENERAL SITE NOTES KEY MAP N.T.S. C2.01 C2.03 C2.04 C2.02 TEAM BENCH SURFACE MOUNTED BENCH RECYCLING RECEPTACLE TRASH RECEPTACLE PLANTER BOX FURNISHING LEGEND NOTE: SEE C2.00 FOR FURNISHING SCHEDULE 4'X8' CONCRETE BENCH PAD (ALTERNATE 1) PROPOSED WALKING TRAIL (ALTERNATE 1) PROPERTY LINE EXISTING FENCE ADA PARKING ENLARGEMENT NC GRID (NAD83) GRAPHIC SCALE 0 5 10 20 1 inch = 10 ft. 04 18 8. 5 ' 5' 11 ' 18'6' R3' 01 02 6' ADJACENT GRAVEL PARKING LOT 19 EXISTING FIELD #5 05 10 ' R12 5 ' R1 7 5 ' SIGN MUTCD SIGN KEY HANDICAP PARKING R7-8 NO-PARKING SIGN R-7a C3.00 WLM17000-OAG1 - EMD 1" = 100' GRADING PLAN OVERALL NC GRID (NAD83) GRAPHIC SCALE 0 50 100 200 1 inch = 100 ft. CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - O A G 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 4 6 : 3 4 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 GRADING LEGEND GRADING NOTES 1.ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2.OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 3.CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 4.A PRE-CONSTRUCTION CONFERENCE WILL BE HELD PRIOR TO ANY LAND DISTURBING ACTIVITY. AS DEEMED NECESSARY, THE OWNER, ENGINEER, CONTRACTOR, AND REPRESENTATIVES FROM NCDEQ WILL BE INVITED TO ATTEND THE MEETING. FOR NCDEQ REPRESENTATIVES, CONTACT DIVISION OF LAND QUALITY AT (910) 796-7215 PRIOR TO START OF CONSTRUCTION. 5.CONSTRUCTION, MAINTENANCE AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. TIMING OF REMOVAL SHALL BE COORDINATED WITH THE EROSION CONTROL INSPECTOR. 6.EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND, ARE BASED ON A FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO BEGINNING RELATED CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 7.SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES LESS THAN 4:1 (H:V) SHALL BE APPROVED, PLACED AND COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. STORM DRAINAGE NOTES: 1.ALL STORM DRAINAGE PIPES SHOWN SHALL BE REINFORCED CONCRETE (RCP) (MINIMUM CLASS III) UNLESS NOTED OTHERWISE. CONTRACTOR TO COORDINATE WITH THE GEOTECH TO VERIFY TYPE OF BEDDING REQUIRED BASED ON SOIL CONDITIONS. CONTRACTOR TO SELECT REQUIRED CLASS OF PIPE BASED ON DEPTH OF PIPE AND BEDDING PROVIDED PER THE AMERICAN CONCRETE PIPE ASSOCIATION GUIDELINES. 2.ALL STORM DRAINAGE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST CITY OF WILMINGTON STANDARDS. 3.ALL CONCRETE SHALL MEET A MINIMUM 3000 PSI COMPRESSIVE STRENGTH. 4.ALL PIPE JOINTS SHALL BE MADE WITH PREFORMED JOINT SEALER, WHICH CONFORMS TO AASHTO SPECIFICATION M-198 FOR TYPE B FLEXIBLE PLASTIC GASKETS UNLESS OTHERWISE NOTED. 5.ALL BACKFILL SHALL BE NON-PLASTIC IN NATURE, FREE FROM ROOTS, VEGETATION MATTER, WASTE CONSTRUCTION MATERIAL OR OTHER OBJECTIONABLE MATERIAL. SAID MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 6.MATERIALS DEEMED BY THE OWNER'S REPRESENTATIVE AS UNSUITABLE FOR BACKFILL PURPOSES SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. 7.BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER PIPE IS LAID. THE FILL AROUND THE PIPE SHALL BE THOROUGHLY COMPACTED TO 95% OF THE MAXIMUM DRY DENSITY OBTAINABLE WITH THE STANDARD PROCTOR TEST. THE TOP EIGHT (8) INCHES SHALL BE COMPACTED TO 100 PERCENT STANDARD PROCTOR. 8.UNDER NO CIRCUMSTANCES SHALL WATER BE ALLOWED TO RISE IN UNBACKFILLED TRENCHES AFTER PIPE HAS BEEN PLACED. 9.IF THE USE OF WAFFLE BOXES ARE ALLOWED AT THIS SITE, ALL PENETRATIONS FOR STORM DRAINAGE PIPES MUST BE MADE WITHIN THE KNOCK-OUT PORTION OF THE BOX AND NOT AT THE CORNERS WHERE THE STRUCTURAL INTEGRITY MAY BE COMPROMISED. EXISTING SITE ENTRANCE RESTROOM BUILDING FFE: 30.00 EXISTING GAZEBO EXISTING FENCE LINE EXISTING EDGE OF PAVEMENT LEVEL SPREADER LEVEL SPREADER PR O P E R T Y L I N E EXISTING FIELD FIELD #9 FIELD #6 FIELD #8 P R O P E R T Y L I N E FIELD #7 AREA B - SEE SHEET C3.02 AREA C - SEE SHEET C3.03 PROPERTY LINE SEPTIC EXPANSION AREA EXISTING RIP RAP LIMITS OF DIRTURBANCE LIMITS OF DIRTURBANCE EXISTING PARKING EXISTING PARKING EXISTING PARKING EXISTING PARKING EXISTING PARKING EXISTING FIELD MAINTENANCE BUILDING FFE: 31.00 AREA A - SEE SHEET C3.01 SYNTHETIC FIELD AREA D - SEE SHEET C3.04 C3.01 WLM17000-G1 - EMD 1" = 40' NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. AREA A GRADING PLAN CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - G 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 4 6 : 5 7 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 EXISTING GAZEBO TO REMAIN EX. SITE ENTRANCE DRIVE EXISTING FIELD 20' METHANE VENT CLEAR ZONE MATCHLINE - SEE SHEET C3.11 FIELD #11 SYNTHETIC WALKING TRAIL (ALTERNATE 1) CONCRETE BENCH PAD (ALTERNATE 1) WALKING TRAIL (ALTERNATE 1) MATCH EXISTING GRADE AT EDGE OF EXISTING PLAYING SURFACE EXTENDED PLAYING SURFACE AREA TO BE GRADED AND SODDED - SEE NATURAL TURF FIELD PLANS GRADING NOTES 1.ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2.OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 3.CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 4.A PRE-CONSTRUCTION CONFERENCE WILL BE HELD PRIOR TO ANY LAND DISTURBING ACTIVITY. AS DEEMED NECESSARY, THE OWNER, ENGINEER, CONTRACTOR, AND REPRESENTATIVES FROM NCDEQ WILL BE INVITED TO ATTEND THE MEETING. FOR NCDEQ REPRESENTATIVES, CONTACT DIVISION OF LAND QUALITY AT (910) 796-7215 PRIOR TO START OF CONSTRUCTION. 5.CONSTRUCTION, MAINTENANCE AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. TIMING OF REMOVAL SHALL BE COORDINATED WITH THE EROSION CONTROL INSPECTOR. 6.EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND, ARE BASED ON A FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO BEGINNING RELATED CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 7.SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES LESS THAN 4:1 (H:V) SHALL BE APPROVED, PLACED AND COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. STORM DRAINAGE NOTES: 1.ALL STORM DRAINAGE PIPES SHOWN SHALL BE REINFORCED CONCRETE (RCP) (MINIMUM CLASS III) UNLESS NOTED OTHERWISE. CONTRACTOR TO COORDINATE WITH THE GEOTECH TO VERIFY TYPE OF BEDDING REQUIRED BASED ON SOIL CONDITIONS. CONTRACTOR TO SELECT REQUIRED CLASS OF PIPE BASED ON DEPTH OF PIPE AND BEDDING PROVIDED PER THE AMERICAN CONCRETE PIPE ASSOCIATION GUIDELINES. 2.ALL STORM DRAINAGE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST CITY OF WILMINGTON STANDARDS. 3.ALL CONCRETE SHALL MEET A MINIMUM 3000 PSI COMPRESSIVE STRENGTH. 4.ALL PIPE JOINTS SHALL BE MADE WITH PREFORMED JOINT SEALER, WHICH CONFORMS TO AASHTO SPECIFICATION M-198 FOR TYPE B FLEXIBLE PLASTIC GASKETS UNLESS OTHERWISE NOTED. 5.ALL BACKFILL SHALL BE NON-PLASTIC IN NATURE, FREE FROM ROOTS, VEGETATION MATTER, WASTE CONSTRUCTION MATERIAL OR OTHER OBJECTIONABLE MATERIAL. SAID MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 6.MATERIALS DEEMED BY THE OWNER'S REPRESENTATIVE AS UNSUITABLE FOR BACKFILL PURPOSES SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. 7.BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER PIPE IS LAID. THE FILL AROUND THE PIPE SHALL BE THOROUGHLY COMPACTED TO 95% OF THE MAXIMUM DRY DENSITY OBTAINABLE WITH THE STANDARD PROCTOR TEST. THE TOP EIGHT (8) INCHES SHALL BE COMPACTED TO 100 PERCENT STANDARD PROCTOR. 8.UNDER NO CIRCUMSTANCES SHALL WATER BE ALLOWED TO RISE IN UNBACKFILLED TRENCHES AFTER PIPE HAS BEEN PLACED. 9.IF THE USE OF WAFFLE BOXES ARE ALLOWED AT THIS SITE, ALL PENETRATIONS FOR STORM DRAINAGE PIPES MUST BE MADE WITHIN THE KNOCK-OUT PORTION OF THE BOX AND NOT AT THE CORNERS WHERE THE STRUCTURAL INTEGRITY MAY BE COMPROMISED. GRADING LEGEND LIMITS OF DISTURBANCE (ALTERNATES) BASE BID LIMITS OF DISTURBANCE FFE=30.00 FFE=31.00 C3.02 WLM17000-G1 - EMD 1" = 40' NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. AREA B GRADING PLAN CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - G 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 4 7 : 0 4 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 MATCHLINE - SEE SHEET C3.10 MATCHLINE - SEE SHEET C3.12 FIELD #7 FIELD #9 SEE SYNTHETIC TURF GRADING PLAN FOR DETAILED FIELD GRADING WALKING TRAIL (ALTERNATE 1) CONCRETE BENCH PAD (ALTERNATE 1) WALKING PATH (ALTERNATE 1) GRADING NOTES 1.ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2.OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 3.CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 4.A PRE-CONSTRUCTION CONFERENCE WILL BE HELD PRIOR TO ANY LAND DISTURBING ACTIVITY. AS DEEMED NECESSARY, THE OWNER, ENGINEER, CONTRACTOR, AND REPRESENTATIVES FROM NCDEQ WILL BE INVITED TO ATTEND THE MEETING. FOR NCDEQ REPRESENTATIVES, CONTACT DIVISION OF LAND QUALITY AT (910) 796-7215 PRIOR TO START OF CONSTRUCTION. 5.CONSTRUCTION, MAINTENANCE AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. TIMING OF REMOVAL SHALL BE COORDINATED WITH THE EROSION CONTROL INSPECTOR. 6.EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND, ARE BASED ON A FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO BEGINNING RELATED CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 7.SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES LESS THAN 4:1 (H:V) SHALL BE APPROVED, PLACED AND COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. STORM DRAINAGE NOTES: 1.ALL STORM DRAINAGE PIPES SHOWN SHALL BE REINFORCED CONCRETE (RCP) (MINIMUM CLASS III) UNLESS NOTED OTHERWISE. CONTRACTOR TO COORDINATE WITH THE GEOTECH TO VERIFY TYPE OF BEDDING REQUIRED BASED ON SOIL CONDITIONS. CONTRACTOR TO SELECT REQUIRED CLASS OF PIPE BASED ON DEPTH OF PIPE AND BEDDING PROVIDED PER THE AMERICAN CONCRETE PIPE ASSOCIATION GUIDELINES. 2.ALL STORM DRAINAGE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST CITY OF WILMINGTON STANDARDS. 3.ALL CONCRETE SHALL MEET A MINIMUM 3000 PSI COMPRESSIVE STRENGTH. 4.ALL PIPE JOINTS SHALL BE MADE WITH PREFORMED JOINT SEALER, WHICH CONFORMS TO AASHTO SPECIFICATION M-198 FOR TYPE B FLEXIBLE PLASTIC GASKETS UNLESS OTHERWISE NOTED. 5.ALL BACKFILL SHALL BE NON-PLASTIC IN NATURE, FREE FROM ROOTS, VEGETATION MATTER, WASTE CONSTRUCTION MATERIAL OR OTHER OBJECTIONABLE MATERIAL. SAID MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 6.MATERIALS DEEMED BY THE OWNER'S REPRESENTATIVE AS UNSUITABLE FOR BACKFILL PURPOSES SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. 7.BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER PIPE IS LAID. THE FILL AROUND THE PIPE SHALL BE THOROUGHLY COMPACTED TO 95% OF THE MAXIMUM DRY DENSITY OBTAINABLE WITH THE STANDARD PROCTOR TEST. THE TOP EIGHT (8) INCHES SHALL BE COMPACTED TO 100 PERCENT STANDARD PROCTOR. 8.UNDER NO CIRCUMSTANCES SHALL WATER BE ALLOWED TO RISE IN UNBACKFILLED TRENCHES AFTER PIPE HAS BEEN PLACED. 9.IF THE USE OF WAFFLE BOXES ARE ALLOWED AT THIS SITE, ALL PENETRATIONS FOR STORM DRAINAGE PIPES MUST BE MADE WITHIN THE KNOCK-OUT PORTION OF THE BOX AND NOT AT THE CORNERS WHERE THE STRUCTURAL INTEGRITY MAY BE COMPROMISED. GRADING LEGEND SEE NATURAL TURF GRADING PLAN FOR DETAILED FIELD GRADING SEE NATURAL TURF GRADING PLAN FOR DETAILED FIELD GRADING PLAYGROUND AREA (ALTERNATE) DAYLIGHT TO BASE BID SWALE GRADING (ALTERNATE 1) DAYLIGHT TO BASE BID SWALE GRADING (ALTERNATE 1) C3.03 WLM17000-G1 - EMD 1" = 40' NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. AREA C GRADING PLAN CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - G 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 4 7 : 0 9 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 MATCHLINE - SEE SHEET C3.11 GRADING NOTES 1.ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2.OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 3.CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 4.A PRE-CONSTRUCTION CONFERENCE WILL BE HELD PRIOR TO ANY LAND DISTURBING ACTIVITY. AS DEEMED NECESSARY, THE OWNER, ENGINEER, CONTRACTOR, AND REPRESENTATIVES FROM NCDEQ WILL BE INVITED TO ATTEND THE MEETING. FOR NCDEQ REPRESENTATIVES, CONTACT DIVISION OF LAND QUALITY AT (910) 796-7215 PRIOR TO START OF CONSTRUCTION. 5.CONSTRUCTION, MAINTENANCE AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. TIMING OF REMOVAL SHALL BE COORDINATED WITH THE EROSION CONTROL INSPECTOR. 6.EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND, ARE BASED ON A FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO BEGINNING RELATED CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 7.SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES LESS THAN 4:1 (H:V) SHALL BE APPROVED, PLACED AND COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. STORM DRAINAGE NOTES: 1.ALL STORM DRAINAGE PIPES SHOWN SHALL BE REINFORCED CONCRETE (RCP) (MINIMUM CLASS III) UNLESS NOTED OTHERWISE. CONTRACTOR TO COORDINATE WITH THE GEOTECH TO VERIFY TYPE OF BEDDING REQUIRED BASED ON SOIL CONDITIONS. CONTRACTOR TO SELECT REQUIRED CLASS OF PIPE BASED ON DEPTH OF PIPE AND BEDDING PROVIDED PER THE AMERICAN CONCRETE PIPE ASSOCIATION GUIDELINES. 2.ALL STORM DRAINAGE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST CITY OF WILMINGTON STANDARDS. 3.ALL CONCRETE SHALL MEET A MINIMUM 3000 PSI COMPRESSIVE STRENGTH. 4.ALL PIPE JOINTS SHALL BE MADE WITH PREFORMED JOINT SEALER, WHICH CONFORMS TO AASHTO SPECIFICATION M-198 FOR TYPE B FLEXIBLE PLASTIC GASKETS UNLESS OTHERWISE NOTED. 5.ALL BACKFILL SHALL BE NON-PLASTIC IN NATURE, FREE FROM ROOTS, VEGETATION MATTER, WASTE CONSTRUCTION MATERIAL OR OTHER OBJECTIONABLE MATERIAL. SAID MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 6.MATERIALS DEEMED BY THE OWNER'S REPRESENTATIVE AS UNSUITABLE FOR BACKFILL PURPOSES SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. 7.BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER PIPE IS LAID. THE FILL AROUND THE PIPE SHALL BE THOROUGHLY COMPACTED TO 95% OF THE MAXIMUM DRY DENSITY OBTAINABLE WITH THE STANDARD PROCTOR TEST. THE TOP EIGHT (8) INCHES SHALL BE COMPACTED TO 100 PERCENT STANDARD PROCTOR. 8.UNDER NO CIRCUMSTANCES SHALL WATER BE ALLOWED TO RISE IN UNBACKFILLED TRENCHES AFTER PIPE HAS BEEN PLACED. 9.IF THE USE OF WAFFLE BOXES ARE ALLOWED AT THIS SITE, ALL PENETRATIONS FOR STORM DRAINAGE PIPES MUST BE MADE WITHIN THE KNOCK-OUT PORTION OF THE BOX AND NOT AT THE CORNERS WHERE THE STRUCTURAL INTEGRITY MAY BE COMPROMISED. GRADING LEGEND FIELD #6 FIELD #8 CONCRETE BENCH PAD (ALTERNATE 1) WALKING TRAIL (ALTERNATE 1) WALKING TRAIL (ALTERNATE 1) P R O P E R T Y L I N E LEVEL SPREADER LEVEL SPREADER APPROX. EXTENTS OF LANDFILL MATERIAL SEE NATURAL TURF GRADING PLAN FOR DETAILED FIELD GRADING GRADE BREAK BETWEEN FIELDS - SEE NATURAL SURFACE FIELD GRADING PLANS LIMITS OF DISTURBANCE (ALTERNATE) GRADING NOTES 1.ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2.OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 3.CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 4.A PRE-CONSTRUCTION CONFERENCE WILL BE HELD PRIOR TO ANY LAND DISTURBING ACTIVITY. AS DEEMED NECESSARY, THE OWNER, ENGINEER, CONTRACTOR, AND REPRESENTATIVES FROM NCDEQ WILL BE INVITED TO ATTEND THE MEETING. FOR NCDEQ REPRESENTATIVES, CONTACT DIVISION OF LAND QUALITY AT (910) 796-7215 PRIOR TO START OF CONSTRUCTION. 5.CONSTRUCTION, MAINTENANCE AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. TIMING OF REMOVAL SHALL BE COORDINATED WITH THE EROSION CONTROL INSPECTOR. 6.EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND, ARE BASED ON A FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO BEGINNING RELATED CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 7.SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES LESS THAN 4:1 (H:V) SHALL BE APPROVED, PLACED AND COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. STORM DRAINAGE NOTES: 1.ALL STORM DRAINAGE PIPES SHOWN SHALL BE REINFORCED CONCRETE (RCP) (MINIMUM CLASS III) UNLESS NOTED OTHERWISE. CONTRACTOR TO COORDINATE WITH THE GEOTECH TO VERIFY TYPE OF BEDDING REQUIRED BASED ON SOIL CONDITIONS. CONTRACTOR TO SELECT REQUIRED CLASS OF PIPE BASED ON DEPTH OF PIPE AND BEDDING PROVIDED PER THE AMERICAN CONCRETE PIPE ASSOCIATION GUIDELINES. 2.ALL STORM DRAINAGE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST CITY OF WILMINGTON STANDARDS. 3.ALL CONCRETE SHALL MEET A MINIMUM 3000 PSI COMPRESSIVE STRENGTH. 4.ALL PIPE JOINTS SHALL BE MADE WITH PREFORMED JOINT SEALER, WHICH CONFORMS TO AASHTO SPECIFICATION M-198 FOR TYPE B FLEXIBLE PLASTIC GASKETS UNLESS OTHERWISE NOTED. 5.ALL BACKFILL SHALL BE NON-PLASTIC IN NATURE, FREE FROM ROOTS, VEGETATION MATTER, WASTE CONSTRUCTION MATERIAL OR OTHER OBJECTIONABLE MATERIAL. SAID MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 6.MATERIALS DEEMED BY THE OWNER'S REPRESENTATIVE AS UNSUITABLE FOR BACKFILL PURPOSES SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. 7.BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER PIPE IS LAID. THE FILL AROUND THE PIPE SHALL BE THOROUGHLY COMPACTED TO 95% OF THE MAXIMUM DRY DENSITY OBTAINABLE WITH THE STANDARD PROCTOR TEST. THE TOP EIGHT (8) INCHES SHALL BE COMPACTED TO 100 PERCENT STANDARD PROCTOR. 8.UNDER NO CIRCUMSTANCES SHALL WATER BE ALLOWED TO RISE IN UNBACKFILLED TRENCHES AFTER PIPE HAS BEEN PLACED. 9.IF THE USE OF WAFFLE BOXES ARE ALLOWED AT THIS SITE, ALL PENETRATIONS FOR STORM DRAINAGE PIPES MUST BE MADE WITHIN THE KNOCK-OUT PORTION OF THE BOX AND NOT AT THE CORNERS WHERE THE STRUCTURAL INTEGRITY MAY BE COMPROMISED. GRADING LEGEND NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. MATCHLINE - SEE SHEET C3.01 MA T C H L I N E - S E E S H E E T C 3 . 0 2 EXISTING FIELD CONCRETE BENCH PAD (ALTERNATE 1) WALKING TRAIL (ALTERNATE 1) P R O P E R T Y L I N E APPROX. EXTENTS OF LANDFILL MATERIAL LIMITS OF DISTURBANCE (ALTERNATE) C3.04 WLM17000-G1 - EMD 1" = 40' AREA D GRADING PLAN CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - G 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 4 7 : 1 4 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 C4.00 WLM17000-OAU1 - EMD 1" = 100' PLAN OVERALL UTILITYCONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - O A U 1 . d w g , 4/ 2 7 / 2 0 2 1 1 0 : 4 6 : 5 8 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 UTILITY NOTES: 1.ALL SITE WATER & SEWER IMPROVEMENTS SHALL BE IN ACCORDANCE WITH THE LATEST STANDARDS AND SPECIFICATIONS OF THE CAPE FEAR PUBLIC UTILITY AUTHORITY (CFPUA). CONTRACTOR SHALL COORDINATE WITH CFPUA PERSONNEL ON THE TIMING FOR TIE-IN TO EXISTING WATER LINE. 2.WATER LINE SHALL HAVE A MINIMUM COVER OF 36" FROM FINISHED GROUND. 3.THE LOCATIONS INDICATED FOR WATER AND SEWER TO ENTER THE BUILDINGS ARE APPROXIMATE. THE CONTRACTOR SHALL REFER TO PLUMBING PLANS FOR THE EXACT LOCATION OF TIE-IN OR EXTENSIONS INTO THE BUILDINGS AND PROVIDE ADAPTERS AS NECESSARY. 4.THE CONTRACTOR SHALL VERIFY THE LOCATIONS, BOTH HORIZONTALLY AND VERTICALLY, OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO WATER AND SEWER LINE INSTALLATION. ANY CONFLICTS OR DISCREPANCIES SHOULD BE BROUGHT TO THE ATTENTION TO THE ENGINEER IMMEDIATELY. 5.CONTRACTOR SHALL REPAIR ANY UTILITY OR STRUCTURE DAMAGED DUE TO CONSTRUCTION AT NO EXPENSE TO THE OWNER. ANY REPAIRS SHALL BE COORDINATED WITH THE UTILITY OWNER AND ENGINEER. 6.ALL NEW BACKFLOW DEVICES SHALL BE IN ACCORDANCE WITH CAPE FEAR PUBLIC UTILITY AUTHORITY DETAILS AND SPECIFICATIONS. HOT BOX SIZE SHALL BE BASED ON RPDA SELECTED. 7.WATER VALVES LOCATED IN GRAVEL TRAFFIC AREAS TO BE INSTALLED WITH A 2'x2' CONCRETE COLLAR. 8.CLEANOUTS LOCATED IN PAVEMENT OR OTHER TRAFFIC AREAS TO BE LOAD BEARING. 9.ALL UNDERGROUND LINES OUTSIDE THE BUILDING FOOTPRINT, EXCEPT LAWN IRRIGATION LINES, SHALL HAVE A WARNING TAPE INSTALLED IN THE BACKFILL BETWEEN 6 INCHES TO 24 INCHES BELOW FINISHED GRADE DIRECTLY OVER PIPING. 9.1.METALLIC LINES SHALL BE IDENTIFIED WITH DURABLE PRINTED PLASTIC WARNING TAPES, MINIMUM 3 INCHES WIDE WITH LETTERING TO IDENTIFY BURIED LINE BELOW. 9.2.NON-METALLIC PIPES, OTHER THAN GAS LINES, SHALL BE IDENTIFIED BY DETECTABLE WARNING TAPE, MINIMUM 2 INCHES WIDE, WITH LETTERING TO IDENTIFY BURIED LINE BELOW. 9.3.2012 NC FUEL GAS CODE, SECTION 404.15.3 TRACER: AN INSULATED COPPER TRACER WIRE OR OTHER APPROVED CONDUCTOR SHALL BE INSTALLED ADJACENT TO UNDERGROUND NONMETALLIC PIPING. ACCESS SHALL BE PROVIDED TO THE TRACER WIRE OR THE TRACER WIRE SHALL TERMINATE ABOVE GROUND AT THE END OF THE NONMETALLIC PIPING. THE TRACER WIRE SIZE SHALL NOT BE LESS THAN 18-AWG AND THE INSULATION TYPE SUITABLE FOR DIRECT BURIAL. GENERAL NOTES: 1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO GAS OR WATER PIPES, PUBLIC OR PRIVATE SEWERS, DRAINS OR CULVERTS, RAILROAD OR TRAFFIC SIGNAL CABLES, TELEPHONE OR POWER CONDUITS, OR OTHER STRUCTURES. WHEN UTILITY LINES THAT ARE TO BE REMOVED ARE ENCOUNTERED WITHIN THE AREA OF OPERATIONS, THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE WITH AMPLE TIME FOR THE NECESSARY MEASURES TO BE TAKEN TO PREVENT INTERRUPTION OF THE SERVICES. REASONABLE CARE HAS BEEN EXERCISED IN SHOWING THE LOCATION OF EXISTING UTILITIES ON THE PLANS. THE EXACT LOCATION OF SUCH UTILITIES IS NOT KNOWN IN ALL CASES. THE CONTRACTOR SHALL EXPLORE THE AREA AHEAD OF THE GRADING OPERATION BY OBSERVATIONS, ELECTRONIC DEVICES, AND BY PERSONAL CONTACTS WITH UTILITY COMPANIES, AND LOCATE SUCH UTILITIES IN ADVANCE OF THE TRENCHING OR GRADING OPERATIONS, AND SHALL CONDUCT HIS WORK SO AS TO ELIMINATE OR MINIMIZE DAMAGE TO THE EXISTING STRUCTURES OR UTILITIES. 2.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE WITH ALL CURRENT LOCAL, STATE, AND OSHA SAFETY CODES DURING ALL PHASES OF THE WORK. CONTRACT PRICES ESTABLISHED FOR THE WORK SHALL INCLUDE COSTS ASSOCIATED WITH THE PROVISION OF SAFETY EQUIPMENT, AND PERSONNEL NECESSARY TO COMPLETE THE WORK, INCLUDING, BUT NOT LIMITED TO, TRENCH BRACING, AND PERSONNEL LICENSED BY OSHA AS COMPETENT FOR EVALUATING SOIL STABILITY. 3.ALL DISTURBED AREAS SHALL BE RESTORED TO EXISTING OR BETTER CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. 4.CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF EXISTING 8" WATER LINE PRIOR TO TIE-IN AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES. NC GRID (NAD83) GRAPHIC SCALE 0 50 100 200 1 inch = 100 ft. RESTROOM BUILDING EX. IRRIGATION LINE 8-IN WATER LINE (TYP.) 4-IN DOMESTIC WATER SERVICE - SEE SHEET C4.11 FIRE HYDRANT ASSEMBLY 8-IN WATER LINE (TYP.) FIRE HYDRANT ASSEMBLY FIRE HYDRANT ASSEMBLY 8-IN WATER LINE (TYP.) 8-IN WATER LINE (TYP.) 8-IN WATER LINE (TYP.) 20' METHANE VENT CLEAR ZONE 8-IN WATER LINE (TYP.) 8x8-IN TEE WITH ISOLATION VALVES 8x8-IN TEE AND VALVES - SEE SHEET C4.11 6-IN SANITARY SEWER LINE SANITARY SEWER MANHOLE EX. METHANE VENT GAS LINE FIELD LIGHTS - SEE ELECTRICAL PLANS FIELD LIGHTS - SEE ELECTRICAL PLANS FI E L D L I G H T S - S E E EL E C T R I C A L P L A N S FIELD LIGHTS - SEE ELECTRICAL PLANS PARKING LOT LIGHTS - SEE ELECTRICAL SHEETS ELECTRICAL PANEL - SEE ELECTRICAL PLANS UNDERGROUND ELECTRIC LINE - SEE ELECTRICAL PLANS FOOD TRUCK POWER OUTLET - SEE ELECTRICAL PLANS SEPTIC TANKS - SEE SEPTIC PLANS ELECTRICAL PANEL - SEE ELCTRICAL PLANS UNDERGROUND ELECTRIC LINE - SEE ELECTRICAL PLANS UTILITY BOX AND ELECTRICAL CONDUIT LINE - SEE DETAILED FIELD PLANS MAINTENENCE BUILDING MATCHLINE - SEE SHEET C4.01 PARKING LOT LIGHTING CONDUIT - SEE ELECTRICAL PLANS TELEPHONE LINE - SEE ELECTRICAL PLANS PARKING LOT LIGHTING CONDUIT - SEE ELECTRICAL PLANSPARKING LOT LIGHTS - SEE ELECTRICAL PLANS FIELD LIGHTING CONDUIT - SEE ELCTRICAL PLANS PARKING LOT LIGHTS - SEE ELECTRICAL PLANS PARKING LOT LIGHTS - SEE ELECTRICAL PLANS ELECTRIC VEHICLE CHARGING STATION - SEE ELECTRICAL PLANS PARKING LOT LIGHTING CONDUIT - SEE ELECTRICAL PLANS METAL SLEEVE AROUND METHANE GAS LINE - SEE SHEETS V1.00 - V6.00 METHANE GAS LINE - SEE SHEETS V1.00 - V6.00 4-IN DOMESTIC WATER SERVICE LINE (TYP.) 4-IN DOMESTIC WATER SERVICE LINE (TYP.) 4-IN DOMESTIC WATER SERVICE LINE CONNECTED TO EXIST. 4-IN SERVICE STUB OUT (SOUTH) - EXIST. 4-IN LINE (WEST) TO BE CAPPED 255.5'255'255'258.5' 25 2 ' 22.5'22.5'22.5' 23' 45'45'45' 26' SEPTIC EXPANSION AREA - SEE SEPTIC PLANS TELEPHONE LINE - SEE ELECTRICAL PLANS UNDERGROUND ELECTRIC LINE - SEE ELECTRICAL PLANS EXISTING WATER METER (ID: 16997908) TO BE RELOCATED TO NEW RESTROOM BLDG. AREA B - SEE SHEET C4.12 AREA C - SEE SHEET C4.13 AREA A - SEE SHEET C4.11 SUBSURFACE METHANE GAS WELL AT RELOCATED ABOVE GRADE METHANE GAS VENT - SEE SHEETS V1.00 - V6.00 UTILITY LEGEND REFER TO IRRIGATION PLANS FOR PROPOSED SOUTHERN FIELD IRRIGATION INFORMATION TELEPHONE LINE - SEE ELECTRICAL PLANS DRIVEWAY LIGHTS BY OTHERS - COST ESTIMATOR TO PRICE AS OWNER COST SIGN LIGHTS AND SWITCH - SEE ELECTRICAL DRAWINGS 15' 20' C4.01 WLM17000-OAU1 - EMD 1" = 100' PLAN OVERALL UTILITYCONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - O A U 1 . d w g , 4/ 2 7 / 2 0 2 1 1 0 : 4 7 : 0 4 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 MATCHLINE - SEE SHEET C4.00 NC GRID (NAD83) GRAPHIC SCALE 0 50 100 200 1 inch = 100 ft. 8-IN PRIVATE FIRE LINE TIE PROPOSED 8-INCH FIRE LINE INTO EXISTING WATER MAIN WITH 8-IN x 8-IN CUT-IN TEE - SHUTDOWN WILL BE REQUIRED - SEE DETAIL SHEET 8.01 EXISTING 8-IN WATER MAIN EXISTING EDGE OF GRAVEL DRIVE PROPERTY LINE (TYP.) EXISTING STORM PIPE (TYP.) EXISTING STORM PIPE (TYP.) EXISTING WATER SERVICE MAIN EXISTING WETLAND AREA (TYP.) EXISTING WATER SERVICE LINE CONNECTED TO PUBLIC WATER MAIN WITH VALVE AND BACKFLOW PREVENTER 70' WIDE UTILITY EASEMENT 24' WIDE EXIST. DRIVEWAY 23' CLR. TO EDGE OF EASEMENT (TYP.) EXISTING WATER VALVE EXISTING OVERHEAD UTILITY LINES EXISTING POWER POLE EXISTING WETLAND AREA (TYP.) SUTTON STEAM PLANT R O A D (VARIABLE WIDTH PUBLI C R / W ) BACKFLOW PREVENTER - TO BE APPROVED BY CFPUA COMMUNITY COMPLIANCE 8-IN PRIVATE FIRE LINE APPROX. 60' WIDE R/W APPROX. 20' OFFSET EXIST. 70' WIDE UTILITY EASEMENT ALONG DRIVEWAY PUBLIC R/W NOTE: DELINEATION VALVE REQUIRED 18-IN INSIDE EXIST. PUBLIC R/W IF THE PROPOSED 8-IN PRIVATE LINE CUT-IN TEE IS GREATER THAN 5' FROM THE R/W LINE UTILITY NOTES: 1.ALL SITE WATER & SEWER IMPROVEMENTS SHALL BE IN ACCORDANCE WITH THE LATEST STANDARDS AND SPECIFICATIONS OF THE CAPE FEAR PUBLIC UTILITY AUTHORITY (CFPUA). CONTRACTOR SHALL COORDINATE WITH CFPUA PERSONNEL ON THE TIMING FOR TIE-IN TO EXISTING WATER LINE. 2.WATER LINE SHALL HAVE A MINIMUM COVER OF 36" FROM FINISHED GROUND. 3.THE LOCATIONS INDICATED FOR WATER AND SEWER TO ENTER THE BUILDINGS ARE APPROXIMATE. THE CONTRACTOR SHALL REFER TO PLUMBING PLANS FOR THE EXACT LOCATION OF TIE-IN OR EXTENSIONS INTO THE BUILDINGS AND PROVIDE ADAPTERS AS NECESSARY. 4.THE CONTRACTOR SHALL VERIFY THE LOCATIONS, BOTH HORIZONTALLY AND VERTICALLY, OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO WATER AND SEWER LINE INSTALLATION. ANY CONFLICTS OR DISCREPANCIES SHOULD BE BROUGHT TO THE ATTENTION TO THE ENGINEER IMMEDIATELY. 5.CONTRACTOR SHALL REPAIR ANY UTILITY OR STRUCTURE DAMAGED DUE TO CONSTRUCTION AT NO EXPENSE TO THE OWNER. ANY REPAIRS SHALL BE COORDINATED WITH THE UTILITY OWNER AND ENGINEER. 6.ALL NEW BACKFLOW DEVICES SHALL BE IN ACCORDANCE WITH CAPE FEAR PUBLIC UTILITY AUTHORITY DETAILS AND SPECIFICATIONS. HOT BOX SIZE SHALL BE BASED ON RPDA SELECTED. 7.WATER VALVES LOCATED IN GRAVEL TRAFFIC AREAS TO BE INSTALLED WITH A 2'x2' CONCRETE COLLAR. 8.CLEANOUTS LOCATED IN PAVEMENT OR OTHER TRAFFIC AREAS TO BE LOAD BEARING. 9.ALL UNDERGROUND LINES OUTSIDE THE BUILDING FOOTPRINT, EXCEPT LAWN IRRIGATION LINES, SHALL HAVE A WARNING TAPE INSTALLED IN THE BACKFILL BETWEEN 6 INCHES TO 24 INCHES BELOW FINISHED GRADE DIRECTLY OVER PIPING. 9.1.METALLIC LINES SHALL BE IDENTIFIED WITH DURABLE PRINTED PLASTIC WARNING TAPES, MINIMUM 3 INCHES WIDE WITH LETTERING TO IDENTIFY BURIED LINE BELOW. 9.2.NON-METALLIC PIPES, OTHER THAN GAS LINES, SHALL BE IDENTIFIED BY DETECTABLE WARNING TAPE, MINIMUM 2 INCHES WIDE, WITH LETTERING TO IDENTIFY BURIED LINE BELOW. 9.3.2012 NC FUEL GAS CODE, SECTION 404.15.3 TRACER: AN INSULATED COPPER TRACER WIRE OR OTHER APPROVED CONDUCTOR SHALL BE INSTALLED ADJACENT TO UNDERGROUND NONMETALLIC PIPING. ACCESS SHALL BE PROVIDED TO THE TRACER WIRE OR THE TRACER WIRE SHALL TERMINATE ABOVE GROUND AT THE END OF THE NONMETALLIC PIPING. THE TRACER WIRE SIZE SHALL NOT BE LESS THAN 18-AWG AND THE INSULATION TYPE SUITABLE FOR DIRECT BURIAL. GENERAL NOTES: 1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO GAS OR WATER PIPES, PUBLIC OR PRIVATE SEWERS, DRAINS OR CULVERTS, RAILROAD OR TRAFFIC SIGNAL CABLES, TELEPHONE OR POWER CONDUITS, OR OTHER STRUCTURES. WHEN UTILITY LINES THAT ARE TO BE REMOVED ARE ENCOUNTERED WITHIN THE AREA OF OPERATIONS, THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE WITH AMPLE TIME FOR THE NECESSARY MEASURES TO BE TAKEN TO PREVENT INTERRUPTION OF THE SERVICES. REASONABLE CARE HAS BEEN EXERCISED IN SHOWING THE LOCATION OF EXISTING UTILITIES ON THE PLANS. THE EXACT LOCATION OF SUCH UTILITIES IS NOT KNOWN IN ALL CASES. THE CONTRACTOR SHALL EXPLORE THE AREA AHEAD OF THE GRADING OPERATION BY OBSERVATIONS, ELECTRONIC DEVICES, AND BY PERSONAL CONTACTS WITH UTILITY COMPANIES, AND LOCATE SUCH UTILITIES IN ADVANCE OF THE TRENCHING OR GRADING OPERATIONS, AND SHALL CONDUCT HIS WORK SO AS TO ELIMINATE OR MINIMIZE DAMAGE TO THE EXISTING STRUCTURES OR UTILITIES. 2.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE WITH ALL CURRENT LOCAL, STATE, AND OSHA SAFETY CODES DURING ALL PHASES OF THE WORK. CONTRACT PRICES ESTABLISHED FOR THE WORK SHALL INCLUDE COSTS ASSOCIATED WITH THE PROVISION OF SAFETY EQUIPMENT, AND PERSONNEL NECESSARY TO COMPLETE THE WORK, INCLUDING, BUT NOT LIMITED TO, TRENCH BRACING, AND PERSONNEL LICENSED BY OSHA AS COMPETENT FOR EVALUATING SOIL STABILITY. 3.ALL DISTURBED AREAS SHALL BE RESTORED TO EXISTING OR BETTER CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. 4.CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF EXISTING 8" WATER LINE PRIOR TO TIE-IN AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES. UTILITY LEGEND APPROX. 14' FROM EDGE OF EXIST. PAVEMENT TO C.L. OF PIPE SIGN LIGHTS AND SWITCH - SEE ELECTRICAL DRAWINGS SS LINE SS LINE C4.02 WLM17000-OAU1 - EMD 1" = 40' SEWER PROFILE UTILITY PLAN - SANITARYCONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - O A U 1 . d w g , 4/ 2 7 / 2 0 2 1 1 0 : 4 7 : 0 9 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 CONNECTION TO PROPOSED SEPTIC TANK STUB OUT CONNECTION TO RESTROOM BUILDING APPROXIMATE TOP OF LANDFILL CAP BASED ON GEOTECH. REPORT FIELD BORING DATA PROPOSED GRADE AT S.S. CENTERLINE EXISTING GRADE AT S.S. CENTERLINE APPROXIMATE TOP OF LANDFILL CAP BASED ON ASSUMED 18" DEPTH BELOW EXISTING GRADE BEYOND LIMITS OF GEOTECH. BORING LOCATIONS 4' S.S. MANHOLE STA: 04+32.98 RIM = 27.77' FL(in) = 25.03' FL(out) = 24.99' S.S. MANHOLE FOUNDATION - SEE STRUCTURAL PLANS 6-IN SANITARY SEWER SERVICE LINE SANITARY SEWER MANHOLE SEPTIC TANKS - SEE SEPTIC PLANS SEPTIC EXPANSION AREA - SEE SEPTIC PLANS UTILITY LEGEND UTILITY NOTES: 1.ALL SITE WATER & SEWER IMPROVEMENTS SHALL BE IN ACCORDANCE WITH THE LATEST STANDARDS AND SPECIFICATIONS OF THE CAPE FEAR PUBLIC UTILITY AUTHORITY (CFPUA). CONTRACTOR SHALL COORDINATE WITH CFPUA PERSONNEL ON THE TIMING FOR TIE-IN TO EXISTING WATER LINE. 2.WATER LINE SHALL HAVE A MINIMUM COVER OF 36" FROM FINISHED GROUND. 3.THE LOCATIONS INDICATED FOR WATER AND SEWER TO ENTER THE BUILDINGS ARE APPROXIMATE. THE CONTRACTOR SHALL REFER TO PLUMBING PLANS FOR THE EXACT LOCATION OF TIE-IN OR EXTENSIONS INTO THE BUILDINGS AND PROVIDE ADAPTERS AS NECESSARY. 4.THE CONTRACTOR SHALL VERIFY THE LOCATIONS, BOTH HORIZONTALLY AND VERTICALLY, OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO WATER AND SEWER LINE INSTALLATION. ANY CONFLICTS OR DISCREPANCIES SHOULD BE BROUGHT TO THE ATTENTION TO THE ENGINEER IMMEDIATELY. 5.CONTRACTOR SHALL REPAIR ANY UTILITY OR STRUCTURE DAMAGED DUE TO CONSTRUCTION AT NO EXPENSE TO THE OWNER. ANY REPAIRS SHALL BE COORDINATED WITH THE UTILITY OWNER AND ENGINEER. 6.ALL NEW BACKFLOW DEVICES SHALL BE IN ACCORDANCE WITH CAPE FEAR PUBLIC UTILITY AUTHORITY DETAILS AND SPECIFICATIONS. HOT BOX SIZE SHALL BE BASED ON RPDA SELECTED. 7.WATER VALVES LOCATED IN GRAVEL TRAFFIC AREAS TO BE INSTALLED WITH A 2'x2' CONCRETE COLLAR. 8.CLEANOUTS LOCATED IN PAVEMENT OR OTHER TRAFFIC AREAS TO BE LOAD BEARING. 9.ALL UNDERGROUND LINES OUTSIDE THE BUILDING FOOTPRINT, EXCEPT LAWN IRRIGATION LINES, SHALL HAVE A WARNING TAPE INSTALLED IN THE BACKFILL BETWEEN 6 INCHES TO 24 INCHES BELOW FINISHED GRADE DIRECTLY OVER PIPING. 9.1.METALLIC LINES SHALL BE IDENTIFIED WITH DURABLE PRINTED PLASTIC WARNING TAPES, MINIMUM 3 INCHES WIDE WITH LETTERING TO IDENTIFY BURIED LINE BELOW. 9.2.NON-METALLIC PIPES, OTHER THAN GAS LINES, SHALL BE IDENTIFIED BY DETECTABLE WARNING TAPE, MINIMUM 2 INCHES WIDE, WITH LETTERING TO IDENTIFY BURIED LINE BELOW. 9.3.2012 NC FUEL GAS CODE, SECTION 404.15.3 TRACER: AN INSULATED COPPER TRACER WIRE OR OTHER APPROVED CONDUCTOR SHALL BE INSTALLED ADJACENT TO UNDERGROUND NONMETALLIC PIPING. ACCESS SHALL BE PROVIDED TO THE TRACER WIRE OR THE TRACER WIRE SHALL TERMINATE ABOVE GROUND AT THE END OF THE NONMETALLIC PIPING. THE TRACER WIRE SIZE SHALL NOT BE LESS THAN 18-AWG AND THE INSULATION TYPE SUITABLE FOR DIRECT BURIAL. GENERAL NOTES: 1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO GAS OR WATER PIPES, PUBLIC OR PRIVATE SEWERS, DRAINS OR CULVERTS, RAILROAD OR TRAFFIC SIGNAL CABLES, TELEPHONE OR POWER CONDUITS, OR OTHER STRUCTURES. WHEN UTILITY LINES THAT ARE TO BE REMOVED ARE ENCOUNTERED WITHIN THE AREA OF OPERATIONS, THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE WITH AMPLE TIME FOR THE NECESSARY MEASURES TO BE TAKEN TO PREVENT INTERRUPTION OF THE SERVICES. REASONABLE CARE HAS BEEN EXERCISED IN SHOWING THE LOCATION OF EXISTING UTILITIES ON THE PLANS. THE EXACT LOCATION OF SUCH UTILITIES IS NOT KNOWN IN ALL CASES. THE CONTRACTOR SHALL EXPLORE THE AREA AHEAD OF THE GRADING OPERATION BY OBSERVATIONS, ELECTRONIC DEVICES, AND BY PERSONAL CONTACTS WITH UTILITY COMPANIES, AND LOCATE SUCH UTILITIES IN ADVANCE OF THE TRENCHING OR GRADING OPERATIONS, AND SHALL CONDUCT HIS WORK SO AS TO ELIMINATE OR MINIMIZE DAMAGE TO THE EXISTING STRUCTURES OR UTILITIES. 2.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE WITH ALL CURRENT LOCAL, STATE, AND OSHA SAFETY CODES DURING ALL PHASES OF THE WORK. CONTRACT PRICES ESTABLISHED FOR THE WORK SHALL INCLUDE COSTS ASSOCIATED WITH THE PROVISION OF SAFETY EQUIPMENT, AND PERSONNEL NECESSARY TO COMPLETE THE WORK, INCLUDING, BUT NOT LIMITED TO, TRENCH BRACING, AND PERSONNEL LICENSED BY OSHA AS COMPETENT FOR EVALUATING SOIL STABILITY. 3.ALL DISTURBED AREAS SHALL BE RESTORED TO EXISTING OR BETTER CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. 4.CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF EXISTING 8" WATER LINE PRIOR TO TIE-IN AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES. NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. 0 20 40 80 1 inch = 40 ft. 0 2 4 8 1 inch = 4 ft. GRAPHIC SCALE - VERTICAL (EXAGGERATED 10X) GRAPHIC SCALE - HORIZONTAL DOUBLE 4" SS CLEANOUT AT 6-IN SS SERVICE LINE CONNECTION TO SEPTIC TANK STUB OUT - SEE SEPTIC PLANS 6-IN SANITARY SEWER SERVICE LINE PROPOSED GRADE AT S.S. CENTERLINE 4" S.S. CLEANOUT STA: 04+91.14 RIM = 28.88' 4" SS CLEANOUT 4' FROM REST ROOM BUILDING YARD HYDRANT - SEE DETAILED UTILITY SHEETS 4" THICK CONCRETE SLEEVE AROUND PORTION OF SS SERVICE LINE UNDER EXTENTS OF PROPOSED DRIVEWAY. 4" DOUBLE S.S. CLEANOUT STA: 00+00.00 RIM = 24.18' C4.11 WLM17000-U1 - EMD 1" = 40' AREA A UTILITY PLAN CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - U 1 . d w g , 4/ 2 7 / 2 0 2 1 1 0 : 4 7 : 3 1 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 MATCHLINE - SEE SHEET C4.12 NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R EXIST. IRRIGATION LINE 8-IN WATER LINE (TYP.) 8-IN WATER LINE (TYP.) FIRE HYDRANT ASSEMBLY 8-IN WATER LINE (TYP.) 8-IN WATER LINE (TYP.) 20' METHANE VENT CLEAR ZONE 8x8-IN TEE WITH ISOLATION VALVES FIELD LIGHTS - SEE ELECTRICAL PLANS FIELD LIGHTS - SEE ELECTRICAL PLANS PARKING LOT LIGHTING CONDUIT - SEE ELECTRICAL PLANS PARKING LOT LIGHTS - SEE ELECTRICAL PLANS PARKING LOT LIGHTS - SEE ELECTRICAL PLANS PARKING LOT LIGHTING CONDUIT - SEE ELECTRICAL PLANS 4-IN DOMESTIC WATER SERVICE LINE (TYP.) 4-IN DOMESTIC WATER SERVICE LINE CONNECTED TO EXIST. 4-IN SERVICE STUB OUT (SOUTH) - EXIST. 4-IN LINE (WEST) TO BE CAPPED 255.5'255'255'258.5' 25 2 ' 22.5'22.5'22.5' 23' 45'45'45' 26' TELEPHONE LINE - SEE ELECTRICAL PLANS UNDERGROUND ELECTRIC LINE - SEE ELECTRICAL PLANS EXISTING WATER METER (ID: 16997908) TO BE RELOCATED TO NEW RESTROOM BLDG. - SEE SHEET C4.11 TELEPHONE LINE - SEE ELECTRICAL PLANS GENERAL NOTES: 1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO GAS OR WATER PIPES, PUBLIC OR PRIVATE SEWERS, DRAINS OR CULVERTS, RAILROAD OR TRAFFIC SIGNAL CABLES, TELEPHONE OR POWER CONDUITS, OR OTHER STRUCTURES. WHEN UTILITY LINES THAT ARE TO BE REMOVED ARE ENCOUNTERED WITHIN THE AREA OF OPERATIONS, THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE WITH AMPLE TIME FOR THE NECESSARY MEASURES TO BE TAKEN TO PREVENT INTERRUPTION OF THE SERVICES. REASONABLE CARE HAS BEEN EXERCISED IN SHOWING THE LOCATION OF EXISTING UTILITIES ON THE PLANS. THE EXACT LOCATION OF SUCH UTILITIES IS NOT KNOWN IN ALL CASES. THE CONTRACTOR SHALL EXPLORE THE AREA AHEAD OF THE GRADING OPERATION BY OBSERVATIONS, ELECTRONIC DEVICES, AND BY PERSONAL CONTACTS WITH UTILITY COMPANIES, AND LOCATE SUCH UTILITIES IN ADVANCE OF THE TRENCHING OR GRADING OPERATIONS, AND SHALL CONDUCT HIS WORK SO AS TO ELIMINATE OR MINIMIZE DAMAGE TO THE EXISTING STRUCTURES OR UTILITIES. 2.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE WITH ALL CURRENT LOCAL, STATE, AND OSHA SAFETY CODES DURING ALL PHASES OF THE WORK. CONTRACT PRICES ESTABLISHED FOR THE WORK SHALL INCLUDE COSTS ASSOCIATED WITH THE PROVISION OF SAFETY EQUIPMENT, AND PERSONNEL NECESSARY TO COMPLETE THE WORK, INCLUDING, BUT NOT LIMITED TO, TRENCH BRACING, AND PERSONNEL LICENSED BY OSHA AS COMPETENT FOR EVALUATING SOIL STABILITY. 3.ALL DISTURBED AREAS SHALL BE RESTORED TO EXISTING OR BETTER CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. 4.CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF EXISTING 8" WATER LINE PRIOR TO TIE-IN AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES. UTILITY LEGEND UTILITY NOTES: 1.ALL SITE WATER & SEWER IMPROVEMENTS SHALL BE IN ACCORDANCE WITH THE LATEST STANDARDS AND SPECIFICATIONS OF THE CAPE FEAR PUBLIC UTILITY AUTHORITY (CFPUA). CONTRACTOR SHALL COORDINATE WITH CFPUA PERSONNEL ON THE TIMING FOR TIE-IN TO EXISTING WATER LINE. 2.WATER LINE SHALL HAVE A MINIMUM COVER OF 36" FROM FINISHED GROUND. 3.THE LOCATIONS INDICATED FOR WATER AND SEWER TO ENTER THE BUILDINGS ARE APPROXIMATE. THE CONTRACTOR SHALL REFER TO PLUMBING PLANS FOR THE EXACT LOCATION OF TIE-IN OR EXTENSIONS INTO THE BUILDINGS AND PROVIDE ADAPTERS AS NECESSARY. 4.THE CONTRACTOR SHALL VERIFY THE LOCATIONS, BOTH HORIZONTALLY AND VERTICALLY, OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO WATER AND SEWER LINE INSTALLATION. ANY CONFLICTS OR DISCREPANCIES SHOULD BE BROUGHT TO THE ATTENTION TO THE ENGINEER IMMEDIATELY. 5.CONTRACTOR SHALL REPAIR ANY UTILITY OR STRUCTURE DAMAGED DUE TO CONSTRUCTION AT NO EXPENSE TO THE OWNER. ANY REPAIRS SHALL BE COORDINATED WITH THE UTILITY OWNER AND ENGINEER. 6.ALL NEW BACKFLOW DEVICES SHALL BE IN ACCORDANCE WITH CAPE FEAR PUBLIC UTILITY AUTHORITY DETAILS AND SPECIFICATIONS. HOT BOX SIZE SHALL BE BASED ON RPDA SELECTED. 7.WATER VALVES LOCATED IN GRAVEL TRAFFIC AREAS TO BE INSTALLED WITH A 2'x2' CONCRETE COLLAR. 8.CLEANOUTS LOCATED IN PAVEMENT OR OTHER TRAFFIC AREAS TO BE LOAD BEARING. 9.ALL UNDERGROUND LINES OUTSIDE THE BUILDING FOOTPRINT, EXCEPT LAWN IRRIGATION LINES, SHALL HAVE A WARNING TAPE INSTALLED IN THE BACKFILL BETWEEN 6 INCHES TO 24 INCHES BELOW FINISHED GRADE DIRECTLY OVER PIPING. 9.1.METALLIC LINES SHALL BE IDENTIFIED WITH DURABLE PRINTED PLASTIC WARNING TAPES, MINIMUM 3 INCHES WIDE WITH LETTERING TO IDENTIFY BURIED LINE BELOW. 9.2.NON-METALLIC PIPES, OTHER THAN GAS LINES, SHALL BE IDENTIFIED BY DETECTABLE WARNING TAPE, MINIMUM 2 INCHES WIDE, WITH LETTERING TO IDENTIFY BURIED LINE BELOW. 9.3.2012 NC FUEL GAS CODE, SECTION 404.15.3 TRACER: AN INSULATED COPPER TRACER WIRE OR OTHER APPROVED CONDUCTOR SHALL BE INSTALLED ADJACENT TO UNDERGROUND NONMETALLIC PIPING. ACCESS SHALL BE PROVIDED TO THE TRACER WIRE OR THE TRACER WIRE SHALL TERMINATE ABOVE GROUND AT THE END OF THE NONMETALLIC PIPING. THE TRACER WIRE SIZE SHALL NOT BE LESS THAN 18-AWG AND THE INSULATION TYPE SUITABLE FOR DIRECT BURIAL. 10.CONTRACTOR SHALL FOLLOW THE GAS COLLECTION AND VENTING (GCVS) DESIGN REQUIREMENTS FOR INSTALLING AND BACKFILLING UTILITY TRENCHES, INCLUDING IN INSTALLING UTILITY TRENCH DAMS WITHIN THE APPLICABLE UTILITY TRENCHES AS INDICATED IN THE GCVS DESIGN DOCUMENTS (SHEETS V1.00 - V6.00). DRIVEWAY LIGHTS BY OTHERS - COST ESTIMATOR TO PRICE AS OWNER COST 20' 15 ' 20' 15 ' CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - U 1 . d w g , 4/ 2 7 / 2 0 2 1 1 0 : 4 7 : 3 4 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 C4.12 WLM17000-U1 - EMD 1" = 40' AREA B UTILITY PLAN MATCHLINE - SEE SHEET C4.13 RESTROOM BUILDING 4-IN DOMESTIC WATER SERVICE AND ISOLATION VALVE FIRE HYDRANT ASSEMBLY FIRE HYDRANT ASSEMBLY 8-IN FIRE LINE (TYP.) 8-IN FIRE LINE (TYP.) 8x8-IN TEE 8-IN ISOLATION VALVE (TYP.) 6-IN SANITARY SEWER LINE SANITARY SEWER MANHOLE EXIST. METHANE VENT GAS LINE FIELD LIGHTS - SEE ELECTRICAL PLANS PARKING LOT LIGHTS - SEE ELECTRICAL SHEETS ELECTRICAL PANEL - SEE ELECTRICAL PLANS UNDERGROUND ELECTRIC LINE - SEE ELECTRICAL PLANS FOOD TRUCK POWER OUTLET - SEE ELECTRICAL PLANS SEPTIC TANKS - SEE SEPTIC PLANS ELECTRICAL PANEL - SEE ELCTRICAL PLANS UNDERGROUND ELECTRIC LINE - SEE ELECTRICAL PLANS UTILITY BOX AND ELECTRICAL CONDUIT LINE - SEE DETAILED FIELD PLANS MAINTENENCE BUILDING PARKING LOT LIGHTING CONDUIT - SEE ELECTRICAL PLANS TELEPHONE LINE - SEE ELECTRICAL PLANS FIELD LIGHTING CONDUIT - SEE ELCTRICAL PLANS PARKING LOT LIGHTS - SEE ELECTRICAL PLANS ELECTRIC VEHICLE CHARGING STATION - SEE ELECTRICAL PLANS METAL SLEEVE AROUND METHANE GAS LINE - SEE SHEETS V1.00 - V6.00 4-IN DOMESTIC WATER SERVICE LINE (TYP.) SEPTIC EXPANSION AREA - SEE SEPTIC PLANS NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R RELOCATED WATER METER GENERAL NOTES: 1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO GAS OR WATER PIPES, PUBLIC OR PRIVATE SEWERS, DRAINS OR CULVERTS, RAILROAD OR TRAFFIC SIGNAL CABLES, TELEPHONE OR POWER CONDUITS, OR OTHER STRUCTURES. WHEN UTILITY LINES THAT ARE TO BE REMOVED ARE ENCOUNTERED WITHIN THE AREA OF OPERATIONS, THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE WITH AMPLE TIME FOR THE NECESSARY MEASURES TO BE TAKEN TO PREVENT INTERRUPTION OF THE SERVICES. REASONABLE CARE HAS BEEN EXERCISED IN SHOWING THE LOCATION OF EXISTING UTILITIES ON THE PLANS. THE EXACT LOCATION OF SUCH UTILITIES IS NOT KNOWN IN ALL CASES. THE CONTRACTOR SHALL EXPLORE THE AREA AHEAD OF THE GRADING OPERATION BY OBSERVATIONS, ELECTRONIC DEVICES, AND BY PERSONAL CONTACTS WITH UTILITY COMPANIES, AND LOCATE SUCH UTILITIES IN ADVANCE OF THE TRENCHING OR GRADING OPERATIONS, AND SHALL CONDUCT HIS WORK SO AS TO ELIMINATE OR MINIMIZE DAMAGE TO THE EXISTING STRUCTURES OR UTILITIES. 2.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE WITH ALL CURRENT LOCAL, STATE, AND OSHA SAFETY CODES DURING ALL PHASES OF THE WORK. CONTRACT PRICES ESTABLISHED FOR THE WORK SHALL INCLUDE COSTS ASSOCIATED WITH THE PROVISION OF SAFETY EQUIPMENT, AND PERSONNEL NECESSARY TO COMPLETE THE WORK, INCLUDING, BUT NOT LIMITED TO, TRENCH BRACING, AND PERSONNEL LICENSED BY OSHA AS COMPETENT FOR EVALUATING SOIL STABILITY. 3.ALL DISTURBED AREAS SHALL BE RESTORED TO EXISTING OR BETTER CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. 4.CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF EXISTING 8" WATER LINE PRIOR TO TIE-IN AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES. MATCHLINE - SEE SHEET C4.11 SUBSURFACE METHANE GAS WELL AT RELOCATED ABOVE GRADE METHANE GAS VENT - SEE SHEETS V1.00 - V6.00 METHANE GAS LINE - SEE SHEETS V1.00 - V6.00 METHANE GAS LINE - SEE SHEETS V1.00 - V6.00 UTILITY NOTES: 1.ALL SITE WATER & SEWER IMPROVEMENTS SHALL BE IN ACCORDANCE WITH THE LATEST STANDARDS AND SPECIFICATIONS OF THE CAPE FEAR PUBLIC UTILITY AUTHORITY (CFPUA). CONTRACTOR SHALL COORDINATE WITH CFPUA PERSONNEL ON THE TIMING FOR TIE-IN TO EXISTING WATER LINE. 2.WATER LINE SHALL HAVE A MINIMUM COVER OF 36" FROM FINISHED GROUND. 3.THE LOCATIONS INDICATED FOR WATER AND SEWER TO ENTER THE BUILDINGS ARE APPROXIMATE. THE CONTRACTOR SHALL REFER TO PLUMBING PLANS FOR THE EXACT LOCATION OF TIE-IN OR EXTENSIONS INTO THE BUILDINGS AND PROVIDE ADAPTERS AS NECESSARY. 4.THE CONTRACTOR SHALL VERIFY THE LOCATIONS, BOTH HORIZONTALLY AND VERTICALLY, OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO WATER AND SEWER LINE INSTALLATION. ANY CONFLICTS OR DISCREPANCIES SHOULD BE BROUGHT TO THE ATTENTION TO THE ENGINEER IMMEDIATELY. 5.CONTRACTOR SHALL REPAIR ANY UTILITY OR STRUCTURE DAMAGED DUE TO CONSTRUCTION AT NO EXPENSE TO THE OWNER. ANY REPAIRS SHALL BE COORDINATED WITH THE UTILITY OWNER AND ENGINEER. 6.ALL NEW BACKFLOW DEVICES SHALL BE IN ACCORDANCE WITH CAPE FEAR PUBLIC UTILITY AUTHORITY DETAILS AND SPECIFICATIONS. HOT BOX SIZE SHALL BE BASED ON RPDA SELECTED. 7.WATER VALVES LOCATED IN GRAVEL TRAFFIC AREAS TO BE INSTALLED WITH A 2'x2' CONCRETE COLLAR. 8.CLEANOUTS LOCATED IN PAVEMENT OR OTHER TRAFFIC AREAS TO BE LOAD BEARING. 9.ALL UNDERGROUND LINES OUTSIDE THE BUILDING FOOTPRINT, EXCEPT LAWN IRRIGATION LINES, SHALL HAVE A WARNING TAPE INSTALLED IN THE BACKFILL BETWEEN 6 INCHES TO 24 INCHES BELOW FINISHED GRADE DIRECTLY OVER PIPING. 9.1.METALLIC LINES SHALL BE IDENTIFIED WITH DURABLE PRINTED PLASTIC WARNING TAPES, MINIMUM 3 INCHES WIDE WITH LETTERING TO IDENTIFY BURIED LINE BELOW. 9.2.NON-METALLIC PIPES, OTHER THAN GAS LINES, SHALL BE IDENTIFIED BY DETECTABLE WARNING TAPE, MINIMUM 2 INCHES WIDE, WITH LETTERING TO IDENTIFY BURIED LINE BELOW. 9.3.2012 NC FUEL GAS CODE, SECTION 404.15.3 TRACER: AN INSULATED COPPER TRACER WIRE OR OTHER APPROVED CONDUCTOR SHALL BE INSTALLED ADJACENT TO UNDERGROUND NONMETALLIC PIPING. ACCESS SHALL BE PROVIDED TO THE TRACER WIRE OR THE TRACER WIRE SHALL TERMINATE ABOVE GROUND AT THE END OF THE NONMETALLIC PIPING. THE TRACER WIRE SIZE SHALL NOT BE LESS THAN 18-AWG AND THE INSULATION TYPE SUITABLE FOR DIRECT BURIAL. 10.CONTRACTOR SHALL FOLLOW THE GAS COLLECTION AND VENTING (GCVS) DESIGN REQUIREMENTS FOR INSTALLING AND BACKFILLING UTILITY TRENCHES, INCLUDING IN INSTALLING UTILITY TRENCH DAMS WITHIN THE APPLICABLE UTILITY TRENCHES AS INDICATED IN THE GCVS DESIGN DOCUMENTS (SHEETS V1.00 - V6.00). SANITARY SEWER CLEANOUT YARD HYDRANT AND WATER SERVICE LINE FROM BUILDING UTILITY LEGEND 8-IN ISOLATION VALVE (TYP.) SANITARY SEWER DOUBLE CLEANOUT REFER TO IRRIGATION PLANS FOR PROPOSED SOUTHERN FIELD IRRIGATION INFORMATION METHANE GAS VENT RISER RACK - SEE SHEETS V1.00 - V6.00 CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - U 1 . d w g , 4/ 2 7 / 2 0 2 1 1 0 : 4 7 : 3 9 A M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 C4.13 WLM17000-U1 - EMD 1" = 40' AREA C UTILITY PLAN MATCHLINE - SEE SHEET C4.12 UTILITY LEGEND UTILITY NOTES: 1.ALL SITE WATER & SEWER IMPROVEMENTS SHALL BE IN ACCORDANCE WITH THE LATEST STANDARDS AND SPECIFICATIONS OF THE CAPE FEAR PUBLIC UTILITY AUTHORITY (CFPUA). CONTRACTOR SHALL COORDINATE WITH CFPUA PERSONNEL ON THE TIMING FOR TIE-IN TO EXISTING WATER LINE. 2.WATER LINE SHALL HAVE A MINIMUM COVER OF 36" FROM FINISHED GROUND. 3.THE LOCATIONS INDICATED FOR WATER AND SEWER TO ENTER THE BUILDINGS ARE APPROXIMATE. THE CONTRACTOR SHALL REFER TO PLUMBING PLANS FOR THE EXACT LOCATION OF TIE-IN OR EXTENSIONS INTO THE BUILDINGS AND PROVIDE ADAPTERS AS NECESSARY. 4.THE CONTRACTOR SHALL VERIFY THE LOCATIONS, BOTH HORIZONTALLY AND VERTICALLY, OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO WATER AND SEWER LINE INSTALLATION. ANY CONFLICTS OR DISCREPANCIES SHOULD BE BROUGHT TO THE ATTENTION TO THE ENGINEER IMMEDIATELY. 5.CONTRACTOR SHALL REPAIR ANY UTILITY OR STRUCTURE DAMAGED DUE TO CONSTRUCTION AT NO EXPENSE TO THE OWNER. ANY REPAIRS SHALL BE COORDINATED WITH THE UTILITY OWNER AND ENGINEER. 6.ALL NEW BACKFLOW DEVICES SHALL BE IN ACCORDANCE WITH CAPE FEAR PUBLIC UTILITY AUTHORITY DETAILS AND SPECIFICATIONS. HOT BOX SIZE SHALL BE BASED ON RPDA SELECTED. 7.WATER VALVES LOCATED IN GRAVEL TRAFFIC AREAS TO BE INSTALLED WITH A 2'x2' CONCRETE COLLAR. 8.CLEANOUTS LOCATED IN PAVEMENT OR OTHER TRAFFIC AREAS TO BE LOAD BEARING. 9.ALL UNDERGROUND LINES OUTSIDE THE BUILDING FOOTPRINT, EXCEPT LAWN IRRIGATION LINES, SHALL HAVE A WARNING TAPE INSTALLED IN THE BACKFILL BETWEEN 6 INCHES TO 24 INCHES BELOW FINISHED GRADE DIRECTLY OVER PIPING. 9.1.METALLIC LINES SHALL BE IDENTIFIED WITH DURABLE PRINTED PLASTIC WARNING TAPES, MINIMUM 3 INCHES WIDE WITH LETTERING TO IDENTIFY BURIED LINE BELOW. 9.2.NON-METALLIC PIPES, OTHER THAN GAS LINES, SHALL BE IDENTIFIED BY DETECTABLE WARNING TAPE, MINIMUM 2 INCHES WIDE, WITH LETTERING TO IDENTIFY BURIED LINE BELOW. 9.3.2012 NC FUEL GAS CODE, SECTION 404.15.3 TRACER: AN INSULATED COPPER TRACER WIRE OR OTHER APPROVED CONDUCTOR SHALL BE INSTALLED ADJACENT TO UNDERGROUND NONMETALLIC PIPING. ACCESS SHALL BE PROVIDED TO THE TRACER WIRE OR THE TRACER WIRE SHALL TERMINATE ABOVE GROUND AT THE END OF THE NONMETALLIC PIPING. THE TRACER WIRE SIZE SHALL NOT BE LESS THAN 18-AWG AND THE INSULATION TYPE SUITABLE FOR DIRECT BURIAL. 10.CONTRACTOR SHALL FOLLOW THE GAS COLLECTION AND VENTING (GCVS) DESIGN REQUIREMENTS FOR INSTALLING AND BACKFILLING UTILITY TRENCHES, INCLUDING IN INSTALLING UTILITY TRENCH DAMS WITHIN THE APPLICABLE UTILITY TRENCHES AS INDICATED IN THE GCVS DESIGN DOCUMENTS (SHEETS V1.00 - V6.00). GENERAL NOTES: 1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO GAS OR WATER PIPES, PUBLIC OR PRIVATE SEWERS, DRAINS OR CULVERTS, RAILROAD OR TRAFFIC SIGNAL CABLES, TELEPHONE OR POWER CONDUITS, OR OTHER STRUCTURES. WHEN UTILITY LINES THAT ARE TO BE REMOVED ARE ENCOUNTERED WITHIN THE AREA OF OPERATIONS, THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE WITH AMPLE TIME FOR THE NECESSARY MEASURES TO BE TAKEN TO PREVENT INTERRUPTION OF THE SERVICES. REASONABLE CARE HAS BEEN EXERCISED IN SHOWING THE LOCATION OF EXISTING UTILITIES ON THE PLANS. THE EXACT LOCATION OF SUCH UTILITIES IS NOT KNOWN IN ALL CASES. THE CONTRACTOR SHALL EXPLORE THE AREA AHEAD OF THE GRADING OPERATION BY OBSERVATIONS, ELECTRONIC DEVICES, AND BY PERSONAL CONTACTS WITH UTILITY COMPANIES, AND LOCATE SUCH UTILITIES IN ADVANCE OF THE TRENCHING OR GRADING OPERATIONS, AND SHALL CONDUCT HIS WORK SO AS TO ELIMINATE OR MINIMIZE DAMAGE TO THE EXISTING STRUCTURES OR UTILITIES. 2.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE WITH ALL CURRENT LOCAL, STATE, AND OSHA SAFETY CODES DURING ALL PHASES OF THE WORK. CONTRACT PRICES ESTABLISHED FOR THE WORK SHALL INCLUDE COSTS ASSOCIATED WITH THE PROVISION OF SAFETY EQUIPMENT, AND PERSONNEL NECESSARY TO COMPLETE THE WORK, INCLUDING, BUT NOT LIMITED TO, TRENCH BRACING, AND PERSONNEL LICENSED BY OSHA AS COMPETENT FOR EVALUATING SOIL STABILITY. 3.ALL DISTURBED AREAS SHALL BE RESTORED TO EXISTING OR BETTER CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. 4.CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF EXISTING 8" WATER LINE PRIOR TO TIE-IN AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES. NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R FIELD LIGHTS - SEE ELECTRICAL PLANS METHANE GAS LINE - SEE SHEETS V1.00 - V6.00 FIELD LIGHTING CONDUIT - SEE ELCTRICAL PLANS METHANE GAS LINE - SEE SHEETS V1.00 - V6.00 METHANE GAS VENT AND CLEAR ZONE - SEE SHEETS V1.00 - V6.00 SUBSURFACE METHANE GAS WELL AT RELOCATED ABOVE GRADE METHANE GAS VENT - SEE SHEETS V1.00 - V6.00 REFER TO IRRIGATION PLANS FOR PROPOSED SOUTHERN FIELD IRRIGATION INFORMATION C6 . 0 0 WL M 1 7 0 0 0 - E C 1 -EM D 1" = 1 0 0 ' PL A N - B A S E B I D ER O S I O N C O N T R O L CL I E N T RE V I S I O N S PR O J E C T N O . WL M - 1 7 0 0 0 FI L E N A M E CH E C K E D B Y DR A W N B Y SC A L E DA T E N0 . DA T E X:\Projects\_Shared\WLM\WLM-17000\04-Production\Engineering\Construction Drawings\Current Drawings\WLM17000-EC1.dwg, 4/27/2021 1:01:29 PM, Domonell, Eric Th e J o h n R . M c A d a m s C o m p a n y , I n c . 29 0 5 M e r i d i a n P a r k w a y Du r h a m , N C 2 7 7 1 3 ph o n e 9 1 9 . 3 6 1 . 5 0 0 0 fa x 9 1 9 . 3 6 1 . 2 2 6 9 li c e n s e n u m b e r : C - 0 2 9 3 , C - 1 8 7 ww w . m c a d a m s c o . c o m SH E E T PL A N I N F O R M A T I O N CI T Y O F W I L M I N G T O N 30 5 C H E S T N U T S T R E E T , 5 T H F L O O R WI L M I N G T O N , N C 2 8 4 0 2 PH O N E : 9 1 0 . 3 4 1 . 7 8 3 0 PR E L I M I N A R Y D R A W I N G - N O T R E L E A S E D F O R C O N S T R U C T I O N REGIONAL ATHLETIC COMPLEX SITE PLAN SUBMITTAL 205 SUTTON STEAM PLANT ROAD WILMINGTON, NC 28401 04 . 2 7 . 2 0 2 1 ER O S I O N C O N T R O L L E G E N D EX I S T I N G S I T E EN T R A N C E RE S T R O O M BU I L D I N G LE V E L SP R E A D E R LE V E L SP R E A D E R PROPERTY LIN E EX I S T I N G F I E L D PROPER T Y L I N E EXISTING SEPTIC FIELD PR O P E R T Y L I N E SEPTIC EXPANSIONAREA EXTENTS EXISTINGRIP RAP20' METHANEVENT CLEAR ZON E (TYP) EX I S T I N G F I E L D EXISTING FIELD FI E L D # 9 FI E L D # 6 FI E L D # 8 FI E L D # 7 PR O P E R T Y L I N E LI M I T S O F DI R T U R B A N C E IN L E T P R O T E C T I O N (T Y P . ) IN L E T P R O T E C T I O N (T Y P . ) FI L T E R B E R M ( T Y P . ) FI L T E R B E R M ( T Y P . ) EROSION CONTROL NOTES:1.CONTRACTOR SHALL LOCATE AND VERIFY THE LOCATION AND DEPTH OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TOBEGINNING CONSTRUCTION AND NOTIFY THE ENGINEERING OF ANY CONFLICTS/DISCREPANCIES.2.NEW EROSION AND SEDIMENT CONTROL DEVICES MUST BE INSTALLED AS SHOWN ON PLANS AND INSPECTED PRIOR TO ANYGRADING OR DEMOLITION ON SITE. MAINTENANCE AND REPAIR SHALL BE MADE, AS NECESSARY, DURING CONSTRUCTIONACTIVITIES. THE CONTRACTOR SHALL CALL FOR AN INSPECTION ONCE INITIAL MEASURES ARE IN PLACE.3.SEDIMENT/EROSION CONTROL DEVICES MUST BE CHECKED AFTER EACH STORM EVENT. EACH DEVICE IS TO BE MAINTAINED ORREPLACED IF SEDIMENT ACCUMULATION HAS REACHED ONE HALF THE CAPACITY OF THE DEVICE.4.A COPY OF THE APPROVED EROSION CONTROL PLAN MUST BE ON FILE AT THE JOB SITE AT ALL TIMES.5.INSTALL A RAIN GAUGE (6" CAPACITY OR GREATER) ONSITE.6.ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE MAINTAINED UNTIL ALL UPSLOPE DRAINAGE AREAS HAVE BEENSTABILIZED AND PERMANENT VEGETATION HAS BEEN ESTABLISHED.7.CONSTRUCTION, MAINTENANCE, AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF THE GRADINGCONTRACTOR UNLESS OTHERWISE NOTED. ANY DEWATERING ASSOCIATED WITH THIS PROJECT IS TO BE DONE THROUGH A SILTBAG. CONTRACTOR SHALL WORK IN DRY CONDITIONS TO THE MAXIMUM EXTENT POSSIBLE.8.ANY GRADING BEYOND THE DENUDED LIMITS SHOWN ON THE PLAN IS A VIOLATION OF THE EROSION CONTROL PERMIT AND ISSUBJECT TO A FINE. ANY NEED TO DISTURB BEYOND THE APPROVED PLAN SHALL BE BROUGHT TO THE ATTENTION OF THEOWNER, ENGINEER AND EROSION CONTROL INSPECTOR.9.THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER THAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVECOVER OR OTHER ADEQUATE EROSION-CONTROL DEVICES OR STRUCTURES. IN ANY EVENT, SLOPES LEFT EXPOSED WILL, WITHIN7 OR 14 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITHTEMPORARY GROUND COVER, DEVISES OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION. PERMANENT GROUNDCOVER WILLBE PROVIDED FOR ALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR NO MORE THAN 90 CALENDAR DAYS (WHICHEVER ISSHORTER) FOLLOWING COMPLETION OF CONSTRUCTION. TEMPORARY SEEDING IS NECESSARY TO ACHIEVE EROSION CONTROLON LARGE DENUDED AREAS AND ESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTION SEQUENCE ON THEPLAN. ALL GRADED SLOPES STEEPER THAN 3:1 MUST BE SEEDED & COMPOST LAID WITHIN 7 DAYS OF COMPLETION OF GRADING.ALL REMAINING DISTURBED AREAS ARE TO BE SEEDED AND COMPOST LAID WITHIN 14 DAYS. PERMANENT SWALES ARE TO BESTABILIZED WITHIN 7 DAYS. SEE THE GROUND STABILIZATION CHART FOR ADDITIONAL REQUIREMENTS.10.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIRED BY REPRESENTATIVE OF THE NCDEQ DEMLRDEPARTMENT. ADDITIONAL SILT FENCE OUTLETS AT LOW AREAS MAY BE INSTALLED BY CONTRACTOR AS REQUIRED. E&SCMEASURES ARE TO BE INSTALLED AT ANY AREAS USED FOR CONTRACTOR EQUIPMENT STAGING, MATERIALS LAYDOWN, SPOIL ORWASTE AREA.11.PROTECTION OF EXISTING VEGETATION (IF APPLICABLE): AT THE START OF GRADING INVOLVING THE STRIPPING OF TOPSOIL ORLOWERING OF EXISTING GRADE AROUND A TREE, A CLEAN, SHARP, VERTICAL CUT SHALL BE MADE AT THE EDGE OF THE TREESAVE AREA AT THE SAME TIME AS OTHER EROSION CONTROL MEASURES ARE INSTALLED. THE TREE PROTECTION FENCING SHALLBE INSTALLED ON THE SIDE OF THE CUT FARTHEST AWAY FROM THE TREE TRUNK AND SHALL REMAIN IN PLACE UNTIL ALLCONSTRUCTION IN THE VICINITY OF THE TREES IS COMPLETE. NO STORAGE OF MATERIALS, FILL, OR EQUIPMENT AND NOTRESPASSING SHALL BE ALLOWED WITHIN THE BOUNDARY OF THE PROTECTED AREA AND SHALL BE POSTED ON THE PROTECTIONFENCE. A PROTECTION FENCE CONSTRUCTED OF MATERIAL RESISTANT TO DEGRADATION BY SUN, WIND, AND MOISTURE FORTHE DURATION OF THE CONSTRUCTION, SHALL BE INSTALLED AT THE SAME TIME AS THE EROSION CONTROL MEASURES ANDSHALL BE IN PLACE UNTIL ALL CONSTRUCTION IN THE VICINITY OF THE TREES IS COMPLETE.12.INSTALLATION AND MAINTENANCE OF ALL PROPOSED SEDIMENTATION & EROSION CONTROL MEASURES IS REQUIRED. THECONTRACTOR MAY BE ALLOWED, WITH PRIOR APPROVAL FROM THE OWNER, TO COORDINATE CHANGES TO THE PLAN WITH THEON-SITE NCDEQ DEMLR INSPECTOR AND THE ENGINEER OR THE OWNER'S REPRESENTATIVE.13.CONTRACTOR WILL FIELD LOCATE SILT FENCE OUTLETS AT LOW POINTS IN SILT FENCE AS REQUIRED TO PROVIDE RELIEF FROMCONCENTRATED FLOWS.14.ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION.CONTRACTOR SHALL NOTIFY THE OWNER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION FORNECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONEDUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN.15.REQUIRED CONSTRUCTION/SAFETY FENCING SHALL BE INSTALLED PRIOR TO BEGINNING LAND DISTURBANCE.16.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO KEEP ALL DIRT OFF PAVED ROADS. HEAVY MATS MAY BE USED IN LIEU OFROCK CONSTRUCTION ENTRANCES AS DETERMINED BY THE ON-SITE INSPECTOR.17.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO KEEP ALL SEDIMENT ON SITE AND ENSURE NO SEDIMENT LEAVES THE LIMITSOF DISTURBANCE OF THE PROJECT. THIS MAY REQUIRE INSTALLATION OF ADDITIONAL EROSION CONTROL MEASURES ABOVEAND BEYOND WHAT IS SHOWN ON THE PLANS. IF ENVIRONMENTAL OR SITE CONDITIONS WARRANT ADDITIONAL EROSIONCONTROL MEASURES, CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FROM DEP REPRESENTATIVE. EROSION CONTROLMEASURES DAMAGED OR REQUIRED DUE TO CONTRACTOR ACTIONS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ALLEROSION CONTROL MEASURES SHALL BE PROPERLY MAINTAINED THROUGHOUT CONSTRUCTION AT NO ADDITIONAL COST TODEP.18.ALL CONSTRUCTION DEBRIS SHALL BE TESTED AND DISPOSED OF OFF-SITE IN A STATE PERMITTED LINED LANDFILL.19.ALL EARTHEN MATERIAL BROUGHT TO OR REMOVED FROM THE PROJECT SITE SHALL COME FROM OR BE DELIVERED TO A SITETHAT HAS A CURRENT EROSION AND SEDIMENTATION CONTROL GENERAL NOTES:1.SURVEY PERFORMED BY ATLANTIC COAST SURVEY DATED: MARCH 11, 2019.2.ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES.3.FLOOD NOTE: THIS PROPERTY IS NOT LOCATED IN A SPECIAL FLOOD HAZARD ZONE. IT IS LOCATED INZONE "X" AS DEFINED BY F.E.M.A F.I.R.M COMMUNITY PANEL #3720311900K DATED AUGUST 28, 2018.4.PRIOR TO ANY CLEARING, GRADING OR CONSTRUCTION ACTIVITY, CONSTRUCTION FENCE OR TREEPROTECTION FENCING (IF APPLICABLE) SHALL BE INSTALLED AROUND PROTECTED TREES OR GROVES OFTREES. NO CONSTRUCTION WORKERS, TOOLS, MATERIALS, OR VEHICLES ARE PERMITTED WITHIN THETREE PROTECTION FENCING.5.ANY TREES AND/OR AREAS DESIGNATED TO BE PROTECTED MUST BE PROPERLY BARRICADED WITHFENCING AND PROTECTED THROUGHOUT CONSTRUCTION TO INSURE THAT NO CLEARING, GRADING, ORSTAGING OF MATERIALS WILL OCCUR IN THOSE AREAS.6.PROTECTIVE FENCING IS TO BE MAINTAINED THROUGHOUT THE DURATION OF THE PROJECT, ANDCONTRACTORS SHALL RECEIVE ADEQUATE INSTRUCTION ON TREE PROTECTION METHODS.7.CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIORTO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTORSHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OFNC811. REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY.8.EXISTING UTILITIES AND STRUCTURES SHOWN BOTH UNDERGROUND AND ABOVE GROUND, ARE BASEDON THE BEST AVAILABLE INFORMATION. THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS, BOTHHORIZONTAL AND VERTICAL, PRIOR TO BEGINNING RELATED CONSTRUCTION. ANY DISCREPANCIES SHALLBE REPORTED TO THE ENGINEER IMMEDIATELY.9.CONTRACTOR SHALL ROOT SPADE WITHIN ALL TREE DRIPLINES AND TAKE ALL PRECAUTIONS NECESSARYTO SAVE TREES NOT SHOWN TO BE DEMOLISHED.10.ALL GROUND COVER SHALL BE APPLIED PER CONDITIONS OF THE NPDES PERMIT OR IN CRITICAL AREASAT THE END OF EACH DAY.EROSION CONTROL NARRATIVEWILMINGTON REGIONAL ATHLETIC COMPLEXWILMINGTON, NORTH CAROLINARECEIVING STREAM - NORTHEAST CAPE FEAR RIVERCLASSIFICATION - WS-IV;CAPROJECT NUMBER: WLM-17000DESIGNED BY: XXXXXXXXPROJECT DESCRIPTION:THE REGIONAL ATHLETIC COMPLEX PROJECT CONSISTS OF MODIFICATIONS TO AN EXISTING SOCCERCOMPLEX. THE MODIFICATIONS INVOLVE A NEW CONCESSION/RESTROOM FACILITY, NEW PARKING, NEWTURF SOCCER FIELD AND A NEW ARTIFICIAL TURF SOCCER FIELD. NECESSARY INFRASTRUCTUREIMPROVEMENTS, SUCH AS: WATER, SEWER AND STORM DRAINAGE WILL ACCOMPANY THE PROPOSEDCONSTRUCTION. THE PROPOSED STORM DRAINAGE WILL BE DIRECTED TOWARDS AN EXISTING BODY OFWATER THAT WAS ONCE USED AS A BORROW PIT. SE E D B E D P R E P A R A T I O N : AR E A S T O B E S E E D E D T O B E S C A R I F I E D 4 " D E E P . A FI R M , W E L L P U L V E R I Z E D , U N I F O R M S E E D B E D S H O U L D BE P R O V I D E D . F E R T I L I Z E R S H A L L B E P L A C E D D U R I N G SC A R I F I C A T I O N A S F O L L O W S : LI M E : 4 5 L B S / 1 , 0 0 0 S F PH O S P H O R O U S : 2 0 L B S / 1 , 0 0 0 S F FE R T I L I Z E R : 1 7 L B S / 1 , 0 0 0 S F PE R N O R T H C A R O L I N A S O I L A N D S E D I M E N T A T I O N L A W , A V E G E T A T I V E G R O U N D C O V E R S U F F I C I E N T T O P E R M A N E N T L Y RE S T R A I N E R O S I O N S H A L L B E R E - E S T A B L I S H E D W I T H I N 2 1 C A L E N D A R D A Y S A F T E R C O M P L E T I O N O F A N Y P H A S E O F G R A D I N G . PE R M A N A N T G R O U N D C O V E R F O R A L L D I S T U R B E D A R E A S W I T H I N 1 5 W O R K I N G D A Y S O R 9 0 C A L E N D A R D A Y S ( W H I C H E V E R I S SH O R T E R ) F O L L O W I N G C O M P L E T I O N O F C O N S T R U C T I O N O R D E V E L O P M E N T . SO I L A M E N D M E N T S FO L L O W R E C O M M E N D A T I O N S O F S O I L T E S T S O R S E E D E T A I L S O N S H E E T E C - 2 . MU L C H AP P L Y 4 0 0 0 L B / A C S T R A W . A N C H O R S T R A W B Y A P P L I C A B L E R E Q U I R E M E N T S . MA I N T E N A N C E IN S P E C T A N D R E P A I R M U L C H F R E Q U E N T L Y . R E F E R T I L I Z E I N L A T E W I N T E R O F T H E F O L L O W I N G Y E A R ; U S E S O I L T E S T S O R A P P L Y 15 0 L B / A C 1 0 - 1 0 - 1 0 F E R T L I Z E R . M O W R E G U L A R L Y T O A H E I G H T O F 2 - 4 I N C H E S . CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) ATLEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTIONOR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED.CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDETHEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811".REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY.R NC G R I D ( N A D 8 3 ) GR A P H I C S C A L E 0 50 10 0 20 0 1 i n c h = 1 0 0 f t . ME T H A N E G A S CO L L E C T I O N P I P E (T Y P ) AP P R O X . E X T E N T O F LA N D F I L L M A T E R I A L APPROX. EXTENT OFLANDFILL MATERIAL CO N S T R U C T I O N S E Q U E N C E : 1. OB T A I N A L E T T E R O F A P P R O V A L F O R T H E E R O S I O N C O N T R O L P L A N A N D N D P E S C E R T I F I C A T E O F C O V E R A G E F R O M T H E N. C . D E P A R T M E N T O F E N V I R O N M E N T Q U A L I T Y ( N C D E Q ) . 2. OB T A I N A N A P P R O V E D ( S T A M P E D ) S & E C O N T R O L P L A N A N D K E E P I T O N S I T E , E I T H E R I N T H E I N S P E C T I O N B O X , CO N S T R U C T I O N O F F I C E O R W I T H T H E C O N T R A C T O R . 3. CO N T R A C T O R S H A L L H A V E T H E L I M I T S O F D I S T U R B A N C E F L A G G E D P R I O R T O T H E P R E - C O N S T R U C T I O N M E E T I N G F O R LA N D D I S T U R B A N C E . 4. A P R E - C O N S T R U C T I O N C O N F E R E N C E W I L L B E H E L D P R I O R T O A N Y L A N D D I S T U R B I N G A C T I V I T Y . A S D E E M E D NE C E S S A R Y , T H E O W N E R , E N G I N E E R , C O N T R A C T O R , A N D R E P R E S E N T A T I V E S F R O M N C D E Q W I L L B E I N V I T E D T O AT T E N D T H E M E E T I N G . F O R N C D E Q R E P R E S E N T A T I V E S , C O N T A C T D I V I S I O N O F L A N D Q U A L I T Y A T ( 9 1 0 ) 7 9 6 - 7 2 1 5 PR I O R T O S T A R T O F C O N S T R U C T I O N . 5. IN S T A L L A L L P E R I M E T E R E R O S I O N C O N T R O L M E A S U R E S . C L E A R O N L Y T H O S E A R E A S N E C E S S A R Y T O G A I N A C C E S S T O AN D I N S T A L L E R O S I O N C O N T R O L M E A S U R E S . 6. ON C E I N I T I A L E R O S I O N C O N T R O L M E A S U R E S H A V E B E E N I N S T A L L E D T O A C C E S S T H E S I T E , I N S T A L L R E M A I N I N G ER O S I O N C O N T R O L M E A S U R E S . 9. DE M O L I S H A N Y E X I S T I N G S T R U C T U R E S I N D I C A T E D O N T H E P L A N S . S T R I P A N D S T O C K P I L E T O P S O I L F R O M A R E A S O F PR O P O S E D G R A D I N G . C O N T R A C T O R S H A L L A L S O S E P A R A T E , I N T O A S E P A R A T E S T O C K P I L E , A N Y S O I L D E E M E D RE - U S A B L E O N - S I T E F O R S T R U C T U R A L F I L L O R O T H E R ( A S D E T E R M I N E D B Y T H E O N - S I T E G E O T E C H N I C A L E N G I N E E R ) . ST O C K P I L E S S H A L L B E P R O T E C T E D ( E N C I R C L E D ) W I T H A D O U B L E R O W O F S I L T F E N C E . S T O C K P I L E S I Z E S A N D LO C A T I O N S M U S T B E M I N I M I Z E D D U E T O T H E L I M I T E D S T O R A G E A R E A . A N Y U N U S E D M A T E R I A L F R O M T H E T O P S O I L ST O C K P I L E S H A L L B E R E M O V E D F R O M S I T E A N D D I S P O S E D O F P R O P E R L Y A T T H E C O N T R A C T O R ' S E X P E N S E . CO N T R A C T O R T O D E T E R M I N E S T O C K P I L E L O C A T I O N S O N S I T E D U E T O L I M I T E D S T O R A G E A R E A A N D E X I S T I N G SU R R O U N D I N G V E G E T A T I O N . 10 . PR O V I D E A L L D I S T U R B E D A R E A S W I T H G R O U N D C O V E R W I T H I N 1 4 C A L E N D A R D A Y S A F T E R C O M P L E T I O N O F A N Y PH A S E O F C L E A R I N G , G R U B B I N G O R G R A D I N G . T H E S E E D I N G , S E E D B E D P R E P A R A T I O N , C O M P O S T A N D / O R R O L L E D ER O S I O N C O N T R O L P R O D U C T I N S T A L L A T I O N M U S T B E I N A C C O R D A N C E W I T H T H E S E E D I N G S C H E D U L E P R O V I D E D I N TH I S S & E P L A N . N O T E : S L O P E S I N E X C E S S O F 3 H : 1 V S H A L L B E S T A B I L I Z E D W I T H I N 7 D A Y S A N D F O R M O D E R A T E S L O P E S (S L O P E S L E S S T H A N 3 H : 1 V ) S H A L L B E S T A B I L I Z E D W I T H I N 1 4 D A Y S . S E E T H E G R O U N D S T A B I L I Z A T I O N C H A R T O N T H I S SH E E T F O R A D D I T I O N A L R E Q U I R E M E N T S . 11 . BE G I N F I L L I N G S I T E . 12 . IN S T A L L S T O R M D R A I N A G E O U T F A L L , S E W E R O U T F A L L , W A T E R L I N E E X T E N S I O N , A S W E L L A S U T I L I T I E S U N D E R ME C H A N I C A L P L A N S 13 . FI N E G R A D E S I T E A R E A S A S S H O W N O N T H E C O N S T R U C T I O N D R A W I N G S . S T A B I L I Z E S I T E A S A R E A S A R E B R O U G H T U P TO F I N I S H G R A D E W I T H V E G E T A T I O N , S T O N E , C O N C R E T E , E T C . D U R I N G C O N S T R U C T I O N F I L L , C O N T R A C T O R S H A L L FO L L O W A N Y A D D I T I O N A L G U I D E L I N E S / C R I T E R I A A S I N D I C A T E D B Y T H E G E O T E C H N I C A L E N G I N E E R . 14 . ST A B I L I Z E A N Y R E M A I N I N G A R E A S . 15 . WH E N C O N S T R U C T I O N I S C O M P L E T E A N D A L L A R E A S A R E S T A B I L I Z E D C O M P L E T E L Y , C A L L F O R I N S P E C T I O N B Y N C D E Q , TH E O W N E R , A N D T H E E N G I N E E R . 16 . IF S I T E I S A P P R O V E D , R E M O V E A N Y O T H E R T E M P O R A R Y E R O S I O N C O N T R O L M E A S U R E S A N D S E E D A N Y R E S U L T I N G BA R E A R E A S . A L L R E M A I N I N G P E R M A N E N T E R O S I O N C O N T R O L D E V I C E S ( S U C H A S V E L O C I T Y D I S S I P A T O R S ) S H O U L D B E IN S T A L L E D A T T H I S T I M E . 17 . SE E D A N D S T A B I L I Z E A L L R E M A I N I N G A R E A S . 18 . WH E N V E G E T A T I O N H A S B E C O M E E S T A B L I S H E D ( S E E S E E D I N G / F E R T I L I Z E R N O T E ) , C A L L F O R F I N A L S I T E I N S P E C T I O N B Y EN G I N E E R . EN F O R C E M E N T N O T E 1 . F A I L U R E T O F O L L O W T H I S C O N S T R U C T I O N S E Q U E N C E M A Y R E S U L T I N E N F O R C E M E N T A C T I O N S , IN C L U D I N G B U T N O T L I M I T E D T O C I V I L P E N A L T I E S , I N J U N C T I V E R E L I E F , C R I M I N A L P E N A L T I E S , A N D P E R M I T RE V O C A T I O N . A D D I T I O N A L L Y , O F F - S I T E S E D I M E N T A T I O N M A Y R E S U L T I N R E S T O R A T I O N R E Q U I R E M E N T S . EN F O R C E M E N T N O T E 2 . I F E X C E S S I V E S E D I M E N T I S L E A V I N G T H E S I T E , A R E V I S E D S E D I M E N T A T I O N A N D E R O S I O N CO N T R O L P L A N M A Y B E R E Q U I R E D , W I T H A S S O C I A T E D RE Q U I R E M E N T S F O R A D D I T I O N A L S & E M E A S U R E S . SI L T F E N C E SILT FENCE LIMITS OFDIRTURBANCE SILT FENCE OUTLET ATLOW POINT (TYP.) SI L T F E N C E O U T L E T A T LO W P O I N T ( T Y P . ) SILT FENCE OUTLET ATLOW POINT (TYP.) FL O W E R S ( 6 5 % O F M I X ) CO R E O P S I S L A N C E O L A T A - L A N C E - L E A V E D C O R E O P S I S CO R E O P S I S B A S A L I S - G O L D E N M A N E C O R E O P S I S CO R E O P S I S T I N C T O R I A - P L A I N S C O R E O P S I S RU D B E C K I A H I R T A - B L A C K - E Y E D S U S A N CO R E O P S I S G R A N D I F L O R A - L A R G E F L O W E R C O R E O P S I S CH A M A E C R I S T A F A S C I C U L A T A - P A R T R I D G E P E A EC H I N A C E A P U R P U R A - P U R P L E C O N E F L O W E R BI D E N S C E R N U A - B U R - M A R I G O L D HE L I A N T H U S A N G U S T I F O L I A - N A R R O W - L E A V E D S U N F L O W E R CH A M A E C R I S T A N I C T I T A N S - S E N S I T I V E P E A SO R G H A S T R U M N U T A N S - I N D I A N G R A S S TR I D E N S F L A V A S - T R I D E N S ( P U R P L E T O P ) TR I F O L I U M I N C A R N A T U M - C R I M S O N C L O V E R TR I F O L I U M R E P E N - L A D I N O C L O V E R GR A S S E S ( 2 5 % O F M I X ) SC H I Z A C H Y R I U M S C O P A R I U M - L I T T L E B L U E S T E M EL Y M U S V I R G I N I C U S - V I R G I N I A W I L D R Y E FE S T U C A O V I N A - H A R D F E S C U S FE S T U C A A R U N D I N A C E A - T A L L F E S C U E TE M P O R A R Y C O V E R ( 1 0 % O F M I X ) SE P T 1 - D E C 1 50 L B S / A C R E S E C A L E C E R A E L E - R Y E G R A I N DE C 1 - M A R C H 3 1 50 L B S / A C R E A V E N A S A T I V A - O A T S AP R 1 - A U G 3 1 15 L B S / A C R E U R O C H L O A R A M O S A - B R O W N T O P MI L L E T OR 15 L B S / A C R E H E L I A N T H U S A N N U U S - B L A C K O I L SU N F L O W E R ···· C6 . 0 1 WL M 1 7 0 0 0 - E C 1 -EM D 1" = 1 0 0 ' DE T A I L S ER O S I O N C O N T R O L STANDARD SILT FENCE OUTLET “”CONTRACTOR'S INSPECTION REQUIREMENTS OF EROSION CONTROL MEASURES: ST A N D A R D C O N S T R U C T I O N E N T R A N C E STANDARD TEMPORARY SILT FENCE CL I E N T RE V I S I O N S PR O J E C T N O . WL M - 1 7 0 0 0 FI L E N A M E CH E C K E D B Y DR A W N B Y SC A L E DA T E N0 . DA T E X:\Projects\_Shared\WLM\WLM-17000\04-Production\Engineering\Construction Drawings\Current Drawings\WLM17000-EC1.dwg, 4/27/2021 1:01:34 PM, Domonell, Eric Th e J o h n R . M c A d a m s C o m p a n y , I n c . 29 0 5 M e r i d i a n P a r k w a y Du r h a m , N C 2 7 7 1 3 ph o n e 9 1 9 . 3 6 1 . 5 0 0 0 fa x 9 1 9 . 3 6 1 . 2 2 6 9 li c e n s e n u m b e r : C - 0 2 9 3 , C - 1 8 7 ww w . m c a d a m s c o . c o m SH E E T PL A N I N F O R M A T I O N CI T Y O F W I L M I N G T O N 30 5 C H E S T N U T S T R E E T , 5 T H F L O O R WI L M I N G T O N , N C 2 8 4 0 2 PH O N E : 9 1 0 . 3 4 1 . 7 8 3 0 PR E L I M I N A R Y D R A W I N G - N O T R E L E A S E D F O R C O N S T R U C T I O N REGIONAL ATHLETIC COMPLEX SITE PLAN SUBMITTAL 205 SUTTON STEAM PLANT ROAD WILMINGTON, NC 28401 04 . 2 7 . 2 0 2 1 C6 . 0 2 WL M 1 7 0 0 0 - E C 1 -EM D 1" = 1 0 0 ' DE T A I L S ER O S I O N C O N T R O L FILTER BERM DETAIL CL I E N T RE V I S I O N S PR O J E C T N O . WL M - 1 7 0 0 0 FI L E N A M E CH E C K E D B Y DR A W N B Y SC A L E DA T E N0 . DA T E X:\Projects\_Shared\WLM\WLM-17000\04-Production\Engineering\Construction Drawings\Current Drawings\WLM17000-EC1.dwg, 4/27/2021 1:01:39 PM, Domonell, Eric Th e J o h n R . M c A d a m s C o m p a n y , I n c . 29 0 5 M e r i d i a n P a r k w a y Du r h a m , N C 2 7 7 1 3 ph o n e 9 1 9 . 3 6 1 . 5 0 0 0 fa x 9 1 9 . 3 6 1 . 2 2 6 9 li c e n s e n u m b e r : C - 0 2 9 3 , C - 1 8 7 ww w . m c a d a m s c o . c o m SH E E T PL A N I N F O R M A T I O N CI T Y O F W I L M I N G T O N 30 5 C H E S T N U T S T R E E T , 5 T H F L O O R WI L M I N G T O N , N C 2 8 4 0 2 PH O N E : 9 1 0 . 3 4 1 . 7 8 3 0 PR E L I M I N A R Y D R A W I N G - N O T R E L E A S E D F O R C O N S T R U C T I O N REGIONAL ATHLETIC COMPLEX SITE PLAN SUBMITTAL 205 SUTTON STEAM PLANT ROAD WILMINGTON, NC 28401 04 . 2 7 . 2 0 2 1 WL M 1 7 0 0 0 - E C 1 -EM D 1" = 1 0 0 ' DE T A I L S ER O S I O N C O N T R O L C6 . 0 3 NCG01 GROUND STABILIZATION AND MAT E R I A L S H A N D L I N G EF F E C T I V E : 0 4 / 0 1 / 1 9 GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITHTHE NCG01 CONSTRUCTION GENERAL PERMITImplementing the details and specifications on this plan sheet will result in the constructionactivity being considered compliant with the Ground Stabilization and Materials Handlingsections of the NCG01 Construction General Permit (Sections E and F, respectively). Thepermittee shall comply with the Erosion and Sediment Control plan approved by thedelegated authority having jurisdiction. All details and specifications shown on this sheetmay not apply depending on site conditions and the delegated authority having jurisdiction.GROUND STABILIZATION SPECIFICATIONStabilize the ground sufficiently so that rain will not dislodge the soil. Use one of thetechniques in the table below:POLYACRYLAMIDES (PAMS) AND FLOCCULANTS1.Select flocculants that are appropriate for the soils being exposed duringconstruction, selecting from the NC DWR List of Approved PAMS/Flocculants.2.Apply flocculants at or before the inlets to Erosion and Sediment Control Measures.3.Apply flocculants at the concentrations specified in the NC DWR List of ApprovedPAMS/Flocculants and in accordance with the manufacturer's instructions.4.Provide ponding area for containment of treated Stormwater before dischargingoffsite.5.Store flocculants in leak-proof containers that are kept under storm-resistant coveror surrounded by secondary containment structures. HA Z A R D O U S A N D T O X I C W A S T E 1. Cr e a t e d e s i g n a t e d h a z a r d o u s w a s t e c o l l e c t i o n a r e a s o n - s i t e . 2. Pl a c e h a z a r d o u s w a s t e c o n t a i n e r s u n d e r c o v e r o r i n s e c o n d a r y c o n t a i n m e n t . 3. Do n o t s t o r e h a z a r d o u s c h e m i c a l s , d r u m s o r b a g g e d m a t e r i a l s d i r e c t l y o n t h e g r o u n d . EQUIPMENT AND VEHICLE MAINTENANCE1.Maintain vehicles and equipment to prevent discharge of fl u i d s . 2.Provide drip pans under any stored equipment.3.Identify leaks and repair as soon as feasible, or remove leak i n g e q u i p m e n t f r o m t h e project.4.Collect all spent fluids, store in separate containers and pro p e r l y d i s p o s e a s hazardous waste (recycle when possible).5.Remove leaking vehicles and construction equipment from s e r v i c e u n t i l t h e p r o b l e m has been corrected.6.Bring used fuels, lubricants, coolants, hydraulic fluids and o t h e r p e t r o l e u m p r o d u c t s to a recycling or disposal center that handles these materia l s . LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE1.Never bury or burn waste. Place litter and debris in approve d w a s t e c o n t a i n e r s . 2.Provide a sufficient number and size of waste containers (e.g d u m p s t e r , t r a s h receptacle) on site to contain construction and domestic wa s t e s . 3.Locate waste containers at least 50 feet away from storm dr a i n i n l e t s a n d s u r f a c e waters unless no other alternatives are reasonably available . 4.Locate waste containers on areas that do not receive substa n t i a l a m o u n t s o f r u n o f f from upland areas and does not drain directly to a storm dra i n , s t r e a m o r w e t l a n d . 5.Cover waste containers at the end of each workday and befo r e s t o r m e v e n t s o r provide secondary containment. Repair or replace damaged w a s t e c o n t a i n e r s . 6.Anchor all lightweight items in waste containers during time s o f h i g h w i n d s . 7.Empty waste containers as needed to prevent overflow. Cle a n u p i m m e d i a t e l y i f containers overflow.8.Dispose waste off-site at an approved disposal facility.9.On business days, clean up and dispose of waste in designat e d w a s t e c o n t a i n e r s . PAINT AND OTHER LIQUID WASTE1.Do not dump paint and other liquid waste into storm drains , s t r e a m s o r w e t l a n d s . 2.Locate paint washouts at least 50 feet away from storm dra i n i n l e t s a n d s u r f a c e waters unless no other alternatives are reasonably available . 3.Contain liquid wastes in a controlled area.4.Containment must be labeled, sized and placed appropriate l y f o r t h e n e e d s o f s i t e . 5.Prevent the discharge of soaps, solvents, detergents and oth e r l i q u i d w a s t e s f r o m construction sites.PORTABLE TOILETS1.Install portable toilets on level ground, at least 50 feet away f r o m s t o r m d r a i n s , streams or wetlands unless there is no alternative reasonab l y a v a i l a b l e . I f 5 0 f o o t offset is not attainable, provide relocation of portable toilet b e h i n d s i l t f e n c e o r p l a c e on a gravel pad and surround with sand bags.2.Provide staking or anchoring of portable toilets during perio d s o f h i g h w i n d s o r i n h i g h foot traffic areas.3.Monitor portable toilets for leaking and properly dispose of a n y l e a k e d m a t e r i a l . Utilize a licensed sanitary waste hauler to remove leaking po r t a b l e t o i l e t s a n d r e p l a c e with properly operating unit. HE R B I C I D E S , P E S T I C I D E S A N D R O D E N T I C I D E S 1. St o r e a n d a p p l y h e r b i c i d e s , p e s t i c i d e s a n d r o d e n t i c i d e s i n a c c o r d a n c e w i t h l a b e l re s t r i c t i o n s . 2. St o r e h e r b i c i d e s , p e s t i c i d e s a n d r o d e n t i c i d e s i n t h e i r o r i g i n a l c o n t a i n e r s w i t h t h e la b e l , w h i c h l i s t s d i r e c t i o n s f o r u s e , i n g r e d i e n t s a n d f i r s t a i d s t e p s i n c a s e o f ac c i d e n t a l p o i s o n i n g . 3. Do n o t s t o r e h e r b i c i d e s , p e s t i c i d e s a n d r o d e n t i c i d e s i n a r e a s w h e r e f l o o d i n g i s po s s i b l e o r w h e r e t h e y m a y s p i l l o r l e a k i n t o w e l l s , s t o r m w a t e r d r a i n s , g r o u n d w a t e r or s u r f a c e w a t e r . I f a s p i l l o c c u r s , c l e a n a r e a i m m e d i a t e l y . 4. Do n o t s t o c k p i l e t h e s e m a t e r i a l s o n s i t e . CO N C R E T E W A S H O U T S 1. Do n o t d i s c h a r g e c o n c r e t e o r c e m e n t s l u r r y f r o m t h e s i t e . 2. Di s p o s e o f , o r r e c y c l e s e t t l e d , h a r d e n e d c o n c r e t e r e s i d u e i n a c c o r d a n c e w i t h l o c a l an d s t a t e s o l i d w a s t e r e g u l a t i o n s a n d a t a n a p p r o v e d f a c i l i t y . 3. Ma n a g e w a s h o u t f r o m m o r t a r m i x e r s i n a c c o r d a n c e w i t h t h e a b o v e i t e m a n d i n ad d i t i o n p l a c e t h e m i x e r a n d a s s o c i a t e d m a t e r i a l s o n i m p e r v i o u s b a r r i e r a n d w i t h i n lo t p e r i m e t e r s i l t f e n c e . 4. In s t a l l t e m p o r a r y c o n c r e t e w a s h o u t s p e r l o c a l r e q u i r e m e n t s , w h e r e a p p l i c a b l e . I f a n al t e r n a t e m e t h o d o r p r o d u c t i s t o b e u s e d , c o n t a c t y o u r a p p r o v a l a u t h o r i t y f o r re v i e w a n d a p p r o v a l . I f l o c a l s t a n d a r d d e t a i l s a r e n o t a v a i l a b l e , u s e o n e o f t h e t w o ty p e s o f t e m p o r a r y c o n c r e t e w a s h o u t s p r o v i d e d o n t h i s d e t a i l . 5. Do n o t u s e c o n c r e t e w a s h o u t s f o r d e w a t e r i n g o r s t o r i n g d e f e c t i v e c u r b o r s i d e w a l k se c t i o n s . S t o r m w a t e r a c c u m u l a t e d w i t h i n t h e w a s h o u t m a y n o t b e p u m p e d i n t o o r di s c h a r g e d t o t h e s t o r m d r a i n s y s t e m o r r e c e i v i n g s u r f a c e w a t e r s . L i q u i d w a s t e m u s t be p u m p e d o u t a n d r e m o v e d f r o m p r o j e c t . 6. Lo c a t e w a s h o u t s a t l e a s t 5 0 f e e t f r o m s t o r m d r a i n i n l e t s a n d s u r f a c e w a t e r s u n l e s s i t ca n b e s h o w n t h a t n o o t h e r a l t e r n a t i v e s a r e r e a s o n a b l y a v a i l a b l e . A t a m i n i m u m , in s t a l l p r o t e c t i o n o f s t o r m d r a i n i n l e t ( s ) c l o s e s t t o t h e w a s h o u t w h i c h c o u l d r e c e i v e sp i l l s o r o v e r f l o w . 7. Lo c a t e w a s h o u t s i n a n e a s i l y a c c e s s i b l e a r e a , o n l e v e l g r o u n d a n d i n s t a l l a s t o n e en t r a n c e p a d i n f r o n t o f t h e w a s h o u t . A d d i t i o n a l c o n t r o l s m a y b e r e q u i r e d b y t h e ap p r o v i n g a u t h o r i t y . 8. In s t a l l a t l e a s t o n e s i g n d i r e c t i n g c o n c r e t e t r u c k s t o t h e w a s h o u t w i t h i n t h e p r o j e c t li m i t s . P o s t s i g n a g e o n t h e w a s h o u t i t s e l f t o i d e n t i f y t h i s l o c a t i o n . 9. Re m o v e l e a v i n g s f r o m t h e w a s h o u t w h e n a t a p p r o x i m a t e l y 7 5 % c a p a c i t y t o l i m i t ov e r f l o w e v e n t s . R e p l a c e t h e t a r p , s a n d b a g s o r o t h e r t e m p o r a r y s t r u c t u r a l co m p o n e n t s w h e n n o l o n g e r f u n c t i o n a l . W h e n u t i l i z i n g a l t e r n a t i v e o r p r o p r i e t a r y pr o d u c t s , f o l l o w m a n u f a c t u r e r ' s i n s t r u c t i o n s . 10 . At t h e c o m p l e t i o n o f t h e c o n c r e t e w o r k , r e m o v e r e m a i n i n g l e a v i n g s a n d d i s p o s e o f in a n a p p r o v e d d i s p o s a l f a c i l i t y . F i l l p i t , i f a p p l i c a b l e , a n d s t a b i l i z e a n y d i s t u r b a n c e ca u s e d b y r e m o v a l o f w a s h o u t . EARTHEN STOCKPILE MANAGEMENT1.Show stockpile locations on plans. Locate earthen-material s t o c k p i l e a r e a s a t l e a s t 50 feet away from storm drain inlets, sediment basins, perim e t e r s e d i m e n t c o n t r o l s and surface waters unless it can be shown no other alternat i v e s a r e r e a s o n a b l y available.2.Protect stockpile with silt fence installed along toe of slope w i t h a m i n i m u m o f f s e t o f five feet from the toe of stockpile.3.Provide stable stone access point when feasible.4.Stabilize stockpile within the timeframes provided on this sh e e t a n d i n a c c o r d a n c e with the approved plan and any additional requirements. S o i l s t a b i l i z a t i o n i s d e f i n e d as vegetative, physical or chemical coverage techniques tha t w i l l r e s t r a i n a c c e l e r a t e d erosion on disturbed soils for temporary or permanent cont r o l n e e d s . SECTION E: GROUND STABILIZATIONRequired Ground Stabilization TimeframesNote: After the permanent cessation of construction activities, any areas with temporaryground stabilization shall be converted to permanent ground stabilization as soon aspracticable but in no case longer than 90 calendar days after the last land disturbingactivity. Temporary ground stabilization shall be maintained in a manner to render thesurface stable against accelerated erosion until permanent ground stabilization is achieved.Site Area DescriptionTimeframe variations-7 days for perimeter dikes, swales,ditches, perimeter slopes and HQW Zones-10 days for Falls Lake Watershed unlessthere is zero slope Stabilize within thismany calendardays after ceasingland disturbance77714NoneNone(a)Perimeter dikes,swales, ditches, andperimeter slopes(b)High Quality Water(HQW) Zones(c)Slopes steeper than3:1 If slopes are 10' or less in length and arenot steeper than 2:1, 14 days areallowed(d)Slopes 3:1 to 4:1(e)Areas with slopesflatter than 4:114 -7 days for slopes greater than 50' inlength and with slopes steeper than 4:1-7 days for perimeter dikes, swales,ditches, perimeter slopes and HQWZones-10 days for Falls Lake WatershedNCG01 SELF-INSPECTION, RECORDKEEPIN G A N D R E P O R T I N G EF F E C T I V E : 0 4 / 0 1 / 1 9 PART IIISELF-INSPECTION, RECORDKEEPING AND REPORTINGSECTION A: SELF-INSPECTIONSelf-inspections are required during normal business hours in accordance with the tablebelow. When adverse weather or site conditions would cause the safety of the inspectionpersonnel to be in jeopardy, the inspection may be delayed until the next business day onwhich it is safe to perform the inspection. In addition, when a storm event of equal to orgreater than 1.0 inch occurs outside of normal business hours, the self-inspection shall beperformed upon the commencement of the next business day. Any time when inspectionswere delayed shall be noted in the Inspection Record.NOTE: The rain inspection resets the required 7 calendar day inspection requirement.PART IIISELF-INSPECTION, RECORDKEEPING AND REPORT I N G SECTION B: RECORDKEEPING1.E&SC Plan DocumentationThe approved E&SC plan as well as any approved deviation shall b e k e p t o n t h e s i t e . T h e approved E&SC plan must be kept up-to-date throughout the cov e r a g e u n d e r t h i s p e r m i t . The following items pertaining to the E&SC plan shall be kept on s i t e a n d a v a i l a b l e f o r inspection at all times during normal business hours.2. Additional Documentation to be Kept on Site In addition to the E&SC plan documents above, the following item s s h a l l b e k e p t o n t h e site and available for inspectors at all times during normal busine s s h o u r s , u n l e s s t h e Division provides a site-specific exemption based on unique site c o n d i t i o n s t h a t m a k e this requirement not practical:(a)This General Permit as well as the Certificate of Coverage, afte r i t i s r e c e i v e d . (b)Records of inspections made during the previous twelve mont h s . T h e p e r m i t t e e s h a l l record the required observations on the Inspection Record For m p r o v i d e d b y t h e Division or a similar inspection form that includes all the requi r e d e l e m e n t s . U s e o f electronically-available records in lieu of the required paper co p i e s w i l l b e a l l o w e d i f shown to provide equal access and utility as the hard-copy rec o r d s . PA R T I I I SE L F - I N S P E C T I O N , R E C O R D K E E P I N G A N D R E P O R T I N G SE C T I O N C : R E P O R T I N G 1. Oc c u r r e n c e s t h a t M u s t b e R e p o r t e d Pe r m i t t e e s s h a l l r e p o r t t h e f o l l o w i n g o c c u r r e n c e s : (a ) Vi s i b l e s e d i m e n t d e p o s i t i o n i n a s t r e a m o r w e t l a n d . (b ) Oi l s p i l l s i f : · Th e y a r e 2 5 g a l l o n s o r m o r e , · Th e y a r e l e s s t h a n 2 5 g a l l o n s b u t c a n n o t b e c l e a n e d u p w i t h i n 2 4 h o u r s , · Th e y c a u s e s h e e n o n s u r f a c e w a t e r s ( r e g a r d l e s s o f v o l u m e ) , o r · Th e y a r e w i t h i n 1 0 0 f e e t o f s u r f a c e w a t e r s ( r e g a r d l e s s o f v o l u m e ) . ( c ) R e l e a s e s o f h a z a r d o u s s u b s t a n c e s i n e x c e s s o f r e p o r t a b l e q u a n t i t i e s u n d e r S e c t i o n 3 1 1 of t h e C l e a n W a t e r A c t ( R e f : 4 0 C F R 1 1 0 . 3 a n d 4 0 C F R 1 1 7 . 3 ) o r S e c t i o n 1 0 2 o f C E R C L A (R e f : 4 0 C F R 3 0 2 . 4 ) o r G . S . 1 4 3 - 2 1 5 . 8 5 . (d ) An t i c i p a t e d b y p a s s e s a n d u n a n t i c i p a t e d b y p a s s e s . (e ) No n c o m p l i a n c e w i t h t h e c o n d i t i o n s o f t h i s p e r m i t t h a t m a y e n d a n g e r h e a l t h o r t h e en v i r o n m e n t . 2. Re p o r t i n g T i m e f r a m e s a n d O t h e r R e q u i r e m e n t s Af t e r a p e r m i t t e e b e c o m e s a w a r e o f a n o c c u r r e n c e t h a t m u s t b e r e p o r t e d , h e s h a l l c o n t a c t th e a p p r o p r i a t e D i v i s i o n r e g i o n a l o f f i c e w i t h i n t h e t i m e f r a m e s a n d i n a c c o r d a n c e w i t h t h e ot h e r r e q u i r e m e n t s l i s t e d b e l o w . O c c u r r e n c e s o u t s i d e n o r m a l b u s i n e s s h o u r s m a y a l s o b e re p o r t e d t o t h e D e p a r t m e n t ' s E n v i r o n m e n t a l E m e r g e n c y C e n t e r p e r s o n n e l a t ( 8 0 0 ) 85 8 - 0 3 6 8 . 3. Documentation to be Retained for Three Years All data used to complete the e-NOI and all inspection records sha l l b e m a i n t a i n e d f o r a p e r i o d of three years after project completion and made available upon r e q u e s t . [40 C F R 1 2 2 . 4 1 ] PART II, SECTION G, ITEM (4)DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUTSediment basins and traps that receive runoff from drainage areas of one acre or more shall use outlet structures that withdraw water from the surf a c e w h e n t h e s e d e v i c e s n e e d t o b e d r a w n d o w n for maintenance or close out unless this is infeasible. The circumstances in which it is not feasible to withdraw water from the surface shall be rare ( f o r e x a m p l e , t i m e s w i t h e x t e n d e d c o l d w e a t h e r ) . Non-surface withdrawals from sediment basins shall be allowed only when all of the following criteria have been met:(a)The E&SC plan authority has been provided with documentation of the non-surface withdrawal and the specific time periods or conditions in w h i c h i t w i l l o c c u r . T h e n o n - s u r f a c e w i t h d r a w a l shall not commence until the E&SC plan authority has approved these items,(b)The non-surface withdrawal has been reported as an anticipated bypass in accordance with Part III, Section C, Item (2)(c) and (d) of this permit , (c)Dewatering discharges are treated with controls to minimize discharges of pollutants from stormwater that is removed from the sediment basi n . E x a m p l e s o f a p p r o p r i a t e c o n t r o l s i n c l u d e properly sited, designed and maintained dewatering tanks, weir tanks, and filtration systems,(d)Vegetated, upland areas of the sites or a properly designed stone pad is used to the extent feasible at the outlet of the dewatering treatment d e v i c e s d e s c r i b e d i n I t e m ( c ) a b o v e , (e)Velocity dissipation devices such as check dams, sediment traps, and riprap are provided at the discharge points of all dewatering devices, and(f)Sediment removed from the dewatering treatment devices described in Item (c) above is disposed of in a manner that does not cause depositi o n o f s e d i m e n t i n t o w a t e r s o f t h e U n i t e d S t a t e s . CL I E N T RE V I S I O N S PR O J E C T N O . WL M - 1 7 0 0 0 FI L E N A M E CH E C K E D B Y DR A W N B Y SC A L E DA T E N0 . DA T E X:\Projects\_Shared\WLM\WLM-17000\04-Production\Engineering\Construction Drawings\Current Drawings\WLM17000-EC1.dwg, 4/27/2021 1:01:52 PM, Domonell, Eric Th e J o h n R . M c A d a m s C o m p a n y , I n c . 29 0 5 M e r i d i a n P a r k w a y Du r h a m , N C 2 7 7 1 3 ph o n e 9 1 9 . 3 6 1 . 5 0 0 0 fa x 9 1 9 . 3 6 1 . 2 2 6 9 li c e n s e n u m b e r : C - 0 2 9 3 , C - 1 8 7 ww w . m c a d a m s c o . c o m SH E E T PL A N I N F O R M A T I O N CI T Y O F W I L M I N G T O N 30 5 C H E S T N U T S T R E E T , 5 T H F L O O R WI L M I N G T O N , N C 2 8 4 0 2 PH O N E : 9 1 0 . 3 4 1 . 7 8 3 0 PR E L I M I N A R Y D R A W I N G - N O T R E L E A S E D F O R C O N S T R U C T I O N REGIONAL ATHLETIC COMPLEX SITE PLAN SUBMITTAL 205 SUTTON STEAM PLANT ROAD WILMINGTON, NC 28401 04 . 2 7 . 2 0 2 1 C8.00 WLM17000-D1 - EMD NTS ACCESSIBLE RESERVED PARKING VAN $250 PENALTY MAXIMUM SCALE:N.T.S. ACCESSIBLE PARKING SPACE SIGN 1 SCALE:N.T.S. TYPICAL ACCESSIBLE PARKING SPACE LAYOUT, RAM AND SIGN LOCATIONS 2 CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - D 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 5 2 : 3 3 A M , Do m o n e l l , E r i c The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 SCALE:1"=1'-0" CONCRETE PAVING (HEAVY DUTY) 5SCALE:1/4" = 1'-0" GRAVEL DRIVE AND PARKING LOT 4 SCALE:1"=1'-0" CONCRETE PAVEMENT (PEDESTRIAN) 3 SCALE:1"=1'-0" MULTI-USE TRAIL - DECOMPOSED GRANITE (ALTERNATE 1) 6 2' SHLD5'5'2' SHLD GRADE POINT ORIGINAL GROUND ORIGINAL GROUND GRADE TO THIS LINE COMPACTED SUBGRADE (95% MIN.) CL 0.020.02 VARIES 2:1 MA X 2:1 MA X TYPICAL SECTION - 10' WALKING TRAIL NOT TO SCALE VARIES COMPACTED EARTH 4" #89 STONE (PEA GRAVEL) SURFACE GEOTEXTILE SEPARATOR FABRIC SCALE:1/2" = 1'-0" CONCRETE STEPS 7 SCALE:N.T.S. WHEELSTOP DETAIL 8 SCALE:N.T.S. ADA CROSSWALK 9 SITE AND AMENITY DETAILS C8.01 WLM17000-D1 - EMD NTS SITE AND AMENITY DETAILS SCALE:1" = 1'-0" SAFETY PLAY SURFACE + TIMBER EDGING - ELEVATION (ALTERNATE 3) 11SCALE:1" = 1'-0" SAFETY PLAY SURFACE + TIMBER EDGING (ALTERNATE 3) 10 PRODUCT: 5 INCH SQUARE BOLLARD FINISH: BLACK POWDERCOAT MANUFACTURER: HUNT (OR APPROVED EQUAL) CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - D 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 5 2 : 3 6 A M , Do m o n e l l , E r i c The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 SCALE:1" = 1'-0" PLAYGROUND ADA RAMP (ALTERNATE 3) 12 SCALE:N.T.S. SAFETY BOLLARD 17 SCALE:N.T.S. CHAIN LINK FENCE PRIVACY SLATS - BASIS OF DESIGN 13 SLAT END VIEW TOP LOCKING SLAT SPECIFICATIONS COVERAGE AREA WIRE GAUGE MESH SIZE SLAT WIDTHSLAT NAME 1 3/4" 2" 9 OR 11 6 7/8" 10 LINEAR FEET 10 LINEAR FEET 10 LINEAR FEET 2" 2 1/4" 9 OR 11 11 1/2 OR 12 1 3/32" 1 1/4" TOP LOCK 2" TOP LOCK 2 1/4" TOP LOCK 1 3/4" INSTALLATION INSTRUCTIONS TOP LOCKING SLATS SCALE:1/2" = 1'-0" CHAIN LINK FENCE WITH PRIVACY SLATS 14 SCALE:3/8" = 1'-0" CHAIN LINK FENCE WITH PRIVACY SLATS DOUBLE GATE 15 1' - 0 " 2' - 8 " 3" 6" 2'-0" 7" x 10" BASE PLATE WITH (4) 1/2" MOUNTING HOLES HINGE PIN 2" GALVANIZED STEEL BOLLARD (2) 2" x 1" LOCK TABS WITH 1/2" HOLES SLIDING LOOP HANDLE TO LOCK BOLLARD IN PLACE PATH SURFACE PAVEMENT AND BASE COURSE 4" CONCRETE FOOTING WITH #5 WASHED STONE BASE 95% COMPACTED SUBGRADE NOTE: 1.CONCRETE FOOTING TO MEASURE 2'-0" x 2'-0" SQUARE. SCALE:1" = 1'-0" COLLAPSIBLE BOLLARD DETAIL 18 3' - 0 " 2' - 6 " 6" 1' - 6 " 6" 1" SLOPE 4" DIAM. STEEL PIPE BOLLARD, PAINT YELLOW FINISH GRADE 95% COMPACTED SUBGRADE CONCRETE FOOTING WITH #5 WASHED STONE BASE 1'-6" NOTE: 1.INSTALL (2) RECTANGULAR REFLECTORS PER BOLLARD, (1) ON EACH SIDE FACING TRAFFIC. SCALE:1" = 1'-0" HEAVY DUTY BOLLARD DETAIL 16 C8.02 WLM17000-D1 - EMD NTS SITE AND AMENITY DETAILS CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - D 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 5 2 : 4 1 A M , Do m o n e l l , E r i c The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 SCALE:1/2" = 1'-0" PLAYGROUND DOUBLE GATE (ALTERNATE 3A) 20 SCALE:1/2" = 1'-0" PLAYGROUND FENCE (ALTERNATE 3A) 21SCALE:1/2" = 1'-0" PLAYGROUND SINGLE GATE (ALTERNATE 3A) 19 SCALE:N.T.S. DUMPSTER ENCLOSURE 22 C8.03 WLM17000-D1 - EMD NTS WATER DETAILS CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - D 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 5 2 : 4 9 A M , Do m o n e l l , E r i c The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 C8.04 WLM17000-D1 - EMD NTS STORM DRAINAGE DETAILS CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - D 1 . d w g , 4/ 2 7 / 2 0 2 1 1 1 : 5 2 : 5 3 A M , Do m o n e l l , E r i c The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 NOTE: CITY OF WILMINGTON DETAILS HAVE BEEN PROVIDED WHERE DETAILS WERE NOT AVAILABLE FROM HANOVER COUNTY. N.T.S. WLM17000-SW JES HBD STORMWATER CONTROL MEASURES CONSTRUCTION SPECIFICATIONS GENERAL NOTES 1.PRIOR TO CONSTRUCTION, ANY DISCREPANCIES IN THE PLANS AND NOTES SHALL BE BROUGHT TO THE DESIGN ENGINEER'S ATTENTION IMMEDIATELY. 2.THE LEVEL SPREADER SYSTEM (FOREBAY, VEGETATED FILTER STRIP, ETC) WILL BE REQUIRED TO BE CERTIFIED ONCE CONSTRUCTION IS COMPLETE. 3.ALL CONSTRUCTION ACTIVITY RELATED TO THE PROPOSED FACILITIES SHALL BE PER THE DETAILS AND SPECIFICATIONS SHOWN IN THESE DRAWINGS. SOILS, COMPACTION, AND OTHER MISCELLANEOUS DETAILS AND SPECIFICATIONS MAY BE MODIFIED PER THE RECOMMENDATIONS OF THE ON-SITE GEOTECHNICAL ENGINEER. HOWEVER, PRIOR TO IMPLEMENTATION, THE DESIGN ENGINEER SHALL BE NOTIFIED OF ANY DEVIATION FROM THESE DESIGN DRAWINGS, INCLUDING SHOP DRAWINGS FOR ANY PROPOSED MODIFICATION. 4.ANY REMOVED TOPSOIL SHALL BE STOCKPILED FOR USE IN THE CONSTRUCTION OF THE ENGINEERED FILTER STRIP AT THE FACILITY. PRIOR TO PLACEMENT OF THE 6" LAYER OF TOPSOIL IN THE ENGINEERED FILTER STRIP, THE CONTRACTOR SHALL SCARIFY THE THE TOP 2"-3" OF EXISTING SOIL TO PROMOTE BONDING OF THE TOPSOIL WITH THE EXISTING SOIL. 5.IT IS ANTICIPATED THAT DEWATERING WILL BE NECESSARY IN THE EXCAVATION AREAS FOR THE FACILITIES. THEREFORE, THE CONTRACTOR SHALL FURNISH, INSTALL, OPERATE, AND MAINTAIN ANY PUMPING EQUIPMENT, ETC. NEEDED FOR REMOVAL OF WATER FROM VARIOUS PARTS OF THE LEVEL SPREADER SITES. DURING PLACEMENT OF FILL WITHIN THESE AREAS, THE CONTRACTOR SHALL KEEP THE WATER LEVEL BELOW THE BOTTOM OF THE EXCAVATION / CONSTRUCTION AREAS. THE MANNER IN WHICH THE WATER IS REMOVED SHALL BE SUCH THAT THE EXCAVATION BOTTOM AND SIDE SLOPES ARE STABLE, WITH NO SEDIMENT DISCHARGED FROM THE SITE (I.E. PUMPED WATER MAY NEED TO BE DIRECTED TO AN APPROVED EROSION CONTROL DEVICE SUCH AS A DIRT BAG (ACF ENVIRONMENTAL), OR APPROVED EQUIVALENT, PRIOR TO DISCHARGE). 6.THE LEVEL SPREADER SYSTEM, AS PROPOSED ON THIS PROJECT, MUST BE LOCATED IN COMMON OPEN SPACE, HAVE AN ACCESS AND MAINTENANCE EASEMENT LOCATED AROUND IT, AND INCLUDE AN OPERATIONS AND MAINTENANCE MANUAL (O&M MANUAL) WITH A MAINTENANCE AGREEMENT. MATERIAL SPECIFICATIONS 1.THE CONCRETE FOR THE LEVEL SPREADER FOOTING STRUCTURE SHALL BE MIN 3,000 PSI (28 DAY), SHALL INCLUDE 5-7% ENTRAINED AIR, AND SHALL BE PLACED WITH A 3-5" SLUMP, UNLESS OTHERWISE INDICATED OR DIRECTED BY THE DESIGN ENGINEER OR THE ONSITE GEOTECHNICAL ENGINEER. CONCRETE TESTING SHALL BE PROVIDED WITH THE AS-BUILT CERTIFICATION TO ENSURE THAT THE ABOVE REQUIREMENTS HAVE BEEN ACHIEVED. 2.ALL REINFORCING STEEL SHALL BE #4 CONFORMING TO ASTM A615, GRADE 60, AND SHALL BE INSTALLED WITH A MINIMUM 3" CONCRETE COVER. 3.THE REINFORCED CONCRETE FOOTER SHALL BE PLACED FIRST, FOLLOWED BY THE REINFORCED CONCRETE WALL. 4.NOTE THAT NO CONCRETE SHALL BE PLACED WHEN THE AMBIENT AIR TEMPERATURES ARE EXPECTED TO BE ABOVE 85°F OR BELOW 40°F. CAST-IN-PLACE CONCRETE SHALL BE "WET CURED" AFTER FINISHING FOR A MINIMUM OF 48 HOURS. 5.DOWNSTREAM OF THE LEVEL SPREADER, A FILTER BLANKET IS TO BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. THE FILTER BLANKET WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (NCDOT #57) UNDERLAIN WITH MIRAFI FILTER WEAVE 700 OR ENGINEER APPROVED EQUIVALENT. STATEMENT OF RESPONSIBILITY 1.ALL REQUIRED MAINTENANCE AND INSPECTIONS OF THE FOREBAYS, LEVEL SPREADER STRUCTURES, AND BYPASS CHANNELS SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER'S ASSOCIATION, PER THE EXECUTED OPERATION AND MAINTENANCE AGREEMENT FOR THIS FACILITY. CONSTRUCTION SEQUENCE 1.THE OWNER SHALL OBTAIN A LAND DISTURBING (GRADING) PERMIT AND AN "APPROVAL TO CONSTRUCT" FROM NEW HANOVER COUNTY AND ALL OTHER APPLICABLE AGENCIES (I.E., 404 / 401 PERMITS, STREAM BUFFER INTRUSIONS/MODIFICATIONS, FLOOD PLAIN DEVELOPMENT PERMITS, ETC.) PRIOR TO CONSTRUCTION. 2.INSTALL ALL SEDIMENT AND EROSION CONTROL MEASURES PER THE APPROVED SEDIMENT AND EROSION CONTROL PLAN. THE CONTRACTOR SHALL MAINTAIN ALL APPROVED SEDIMENT AND EROSION CONTROL MEASURES THROUGHOUT THE ENTIRE PROJECT, AS REQUIRED. THE CONTRACTOR SHALL RECEIVE APPROVAL FROM THE EROSION CONTROL INSPECTOR, AS REQUIRED BY GOVERNING AGENCIES, PRIOR TO ANY CLEARING. 3.CLEAR AND GRUB AREA WITHIN THE LIMITS OF THE LEVEL SPREADER SYSTEM AND BYPASS CHANNEL. ALL TREES AND THEIR ENTIRE ROOT SYSTEMS MUST BE REMOVED FROM THE LEVEL SPREADER SYSTEM AND BYPASS CHANNEL FOOTPRINT AREA AND BACK FILLED WITH SUITABLE SOIL MATERIAL. THE BACK FILLED AREAS SHALL BE COMPACTED TO THE STANDARDS SET FORTH IN NOTE #4. PRIOR TO CONSTRUCTING THE LEVEL SPREADER STRUCTURE, FOREBAY, AND BYPASS CHANNEL AT EACH LOCATION, THE AREAS FOR THE ABOVE SHALL BE STRIPPED TO A SUITABLE DEPTH AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER. ANY RESIDUAL SOILS TO BE LEFT IN PLACE MUST BE WELL SCARIFIED TO PROMOTE BONDING WITH NEW COMPACTED FILL. 4.ALL FILL SOILS USED IN THE LEVEL SPREADER CONSTRUCTION SHALL BE COMPACTED TO AT LEAST 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM-698). THE FILL SOILS SHALL BE COMPACTED AT A MOISTURE CONTENT WITHIN -1 TO +3 PERCENT OF ITS OPTIMUM MOISTURE CONTENT. COMPACTION TESTS SHALL BE PERFORMED BY THE ON-SITE GEOTECHNICAL ENGINEER DURING CONSTRUCTION TO VERIFY THAT THE PROPER COMPACTION LEVEL HAS BEEN REACHED. THE FILL SHOULD BE COMPACTED USING A SHEEPSFOOT TYPE COMPACTOR. IN ORDER TO PREVENT DAMAGE TO THE PIPE, NO COMPACTION EQUIPMENT SHALL CROSS ANY PIPE UNTIL MINIMUM COVER IS ESTABLISHED ALONG THE PIPE. 5.THE ON-SITE GEOTECHNICAL ENGINEER SHALL INSPECT THE FOREBAY AND LEVEL SPREADER STRUCTURE SUBGRADE AND THE BYPASS CHANNEL SUBGRADE PRIOR TO PLACEMENT / COMPACTION OF ANY BACK FILL WITHIN THESE AREAS. IF THE CONTRACTOR CONSTRUCTS AND COVERS UP THESE AREAS PRIOR TO INSPECTION, THEN THE SUBGRADE SHALL BE UNCOVERED AND TESTED AT THE CONTRACTOR'S EXPENSE. THE CONSTRUCTION OF THE FOREBAY, LEVEL SPREADER STRUCTURE, AND BYPASS CHANNEL SHALL NOT OCCUR UNTIL APPROVAL OF THE SUBGRADES IS OBTAINED FROM THE ON-SITE GEOTECHNICAL ENGINEER. 6.CONSTRUCT THE LEVEL SPREADER STRUCTURE, INSTALL THE FOREBAY AND BLIND CHANNEL UPSTREAM OF THE LEVEL SPREADER STRUCTURE AND THEN INSTALL THE BYPASS CHANNEL/BERM. IT IS RECOMMENDED THAT THE OUTLET FROM THE FOREBAY TO THE LEVEL SPREADER STRUCTURE BE PLUGGED UNTIL THE LEVEL SPREADER HAS BEEN INSTALLED. WAIT UNTIL LEVEL SPREADER IS COMPLETE AND FILTER STRIP AREA IS CONFRIMED LEVEL BEFORE INSTALLING THE FILTER STRIP VEGETATION. ONCE A PRELIMINARY AS-BUILT OF THE CONSTRUCTED FACILITY IS PROVIDED TO THE DESIGN ENGINEER AND IT HAS BEEN DETERMINED THAT IT HAS BEEN CONSTRUCTED IN GENERAL COMPLIANCE WITH THE PLANS AND SPECIFICATIONS FOR THE FACILITIES, THE DESIGN ENGINEER WILL NOTIFY THE THE CONTRACTOR THAT THE PLUG CAN BE REMOVED. BASED ON THE RESULTS OF THE AS-BUILT SURVEYS, THE ELEVATIONS FOR THE CONCRETE LEVEL SPREADER MAY BE MODIFIED FROM THOSE PROVIDED IN THESE DRAWINGS. N.T.S. STORMWATER CONTROL MEASURE PLAN & DETAILSC10.00 GRAPHIC SCALE 0 25 50 100 1 inch = 50 ft. GRAPHIC SCALE 0 25 50 100 1 inch = 50 ft. I HEREBY CERTIFY THAT THIS PLAN HAS BEEN PREPARED IN ACCORDANCE WITH THE LATEST NEW HANOVER COUNTY ORDINANCES AND STORMWATER DESIGN MANUAL. I (WE) HEREBY CERTIFY THAT I (WE) AM (ARE) THE CURRENT OWNER OF THE PROPERTY AND THAT UPON RECEIPT OF "AUTHORIZATION-TO-CONSTRUCT" ANY CLEARING, GRADING, CONSTRUCTION OR DEVELOPMENT, WILL BE PERFORMED IN ACCORDANCE WITH THIS PLAN AND THAT THE APPLICABLE ORDINANCES AND RULES OF NEW HANOVER COUNTY, THE STATE OF NORTH CAROLINA AND THE FEDERAL GOVERNMENT AND ITS AGENCIES WHICH ARE HEREBY MADE PART OF THIS PLAN. AS THE OWNER, I (WE) ACCEPT FULL RESPONSIBILITY FOR THE CONSTRUCTION AND OPERATION AND MAINTENANCE OF THE PROPOSED FACILITIES. I (WE) WILL NOT ATTEMPT TO TRANSFER OF THIS RESPONSIBILITY WITHOUT THE WRITTEN AUTHORIZATION OF NEW HANOVER COUNTY. CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ W a t e r R e s o u r c e s \ 6 0 % C D s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - S W . d w g , 4/ 2 7 / 2 0 2 1 1 : 0 8 : 2 0 P M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 L1.00 WLM17000-LS1 - GLJ SEE DRAWINGS LANDSCAPE PLAN OVERALL EXISTING SITE ENTRANCE RESTROOM BUILDING EXISTING GAZEBO EXISTING FENCE LINE GRAVEL PARKING LOT 10' CONCRETE SIDEWALK WALKING TRAIL (ALTERNATE 1) LEVEL SPREADER LEVEL SPREADER SITE LEGEND P R O P E R T Y L I N E EXISTING FIELD #10 EXISTING FIELD #5 FIELD #11 SYNTHETIC EXISTING FIELD #1 FIELD #9 FIELD #6 FIELD #8 P R O P E R T Y L I N E RENOVATED PARKING (ALTERNATE 4) AREA A - SEE SHEET L1.01 WALKING TRAIL (ALTERNATE 1) 10' CONCRETE SIDEWALK CONCRETE BENCH PAD FIELD #7 FIELD LIGHTS FIELD LIGHTS RENOVATED PARKING (ALTERNATE 4) AREA B - SEE SHEET L1.02 AREA C - SEE SHEET L1.03 RENOVATED PARKING (ALTERNATE 4) PROPERTY LINE EXISTING RIP RAP NC GRID (NAD83) GRAPHIC SCALE 0 50 100 200 1 inch = 100 ft. PLAYGROUND AND PATH CONNECTION (ALTERNATE 3)MAINTENANCE BLDG. AND FENCE DUMPSTER PAD LANDSCAPE REQUIREMENT SUMMARY TOTAL CANOPY TREES REQUIRED (TREE RETENTION) 15 TREES (2" MIN. DBH) PER 1 ACRE OF DISTURBED AREA DISTURBED AREA: 21.5 AC REQUIRED: = 323 CANOPY TREES [21.5 AC X 15] PROVIDED:= 150 CANOPY TREES BUILDING FOUNDATION PLANTING FOUNDATION PLANTING BED: 12% OF BUILDING FACE ADJACENT TO PARKING LOT BUILDING FACE: 2,080 SF REQUIRED: = 250 SF [12% OF 2,080 SF] PROVIDED:= 1,410 SF INTERIOR LANDSCAPE ISLAND PLANTING LANDSCAPE AREA: 8% OF VEHICULAR USE AREA VEHICULAR USE AREA: 174,506 SF REQUIRED:= 13,961 SF [8% OF 174,506, PER CODE] PROVIDED:= 38,674 SF [MINUMUM OF 16% OF VEHICULAR USE AREA, PER VARIANCE] CANOPY TREES: 1 CANOPY TREE FOR EACH 144 SF OF INTERIOR LANDSCAPE ISLAND PLANTING REQUIRED: = 1 CANOPY TREE FOR EACH 144 SF OF INTERIOR LANDSCAPE ISLAND PLANTING PROVIDED:= ZERO (0): EXEMPTION GRANTED WITH APPROVED VARIANCE (6 TREES (MINIMUM) WITHIN PLANTERS TO BE PROVIDED AT RESTROOM FACILITY) NOTES 1.CODE REQUIREMENTS AMENDED AS PART OF THE VARIANCE REQUEST ARE SHOWN IN BOLD ITALICS TEXT. CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - L P 1 A . d w g , 4/ 2 7 / 2 0 2 1 1 : 3 7 : 5 0 P M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 AREA D - SEE SHEET L1.04 AREA F - SEE SHEET L1.04 KEY MAP N.T.S. L1.01 L1.03 L1.04 L1.04 L1.04 L1.02 AREA E - SEE SHEET L1.04 EXISTING FIELD #2EXISTING FIELD #3 APPROXIMATE EXTENTS OF ALTERNATE 4 APPROXIMATE EXTENTS OF ALTERNATE 4 APPROXIMATE EXTENTS OF ALTERNATE 3 RENOVATED FIELD #4 NOTES 1.SEE SHEET L2.10 FOR LANDSCAPE NOTES, PLANT SCHEDULE, AND LANDSCAPE DETAILS. 2.CONTRACTOR TO PLACE SOD ON AREAS DISTURBED DURING THE INSTALLATION OF ATHLETIC LIGHTS. SEE SPECIFICATION FOR ALLOWANCE. 3.ALL CANOPY AND UNDERSTORY TREES SHALL BE INSTALLED AS PART OF BASE BID. REFER TO BASE BID PLANT SCHEDULE ON L2.02 FOR TREE SPECIES AND QUANTITIES. 4.LANDSCAPE AREAS DEFINED BY ALTERNATE BOUNDARIES SHALL BE INSTALLED WITH THE NOTED ALTERNATE. SEE OVERALL BASE BID LANDSCAPE PLAN AND SCHEDULE (FOR REFERENCE ONLY) FOR LANDSCAPE CONDITIONS SHOULD ALTERNATES, AS DEFINED ON THE OVERALL SITE PLAN, NOT BE CONSTRUCTED. P5 P5 EXISTING GAZEBO TO REMAIN EX. SITE ENTRANCE DRIVE PROPOSED EDGE OF GRAVEL DRIVE EXISTING FIELD #5 PROPOSED EDGE OF GRAVEL DRIVE 20' METHANE VENT CLEAR ZONE MATCHLINE - SEE SHEET L1.02 WALKING TRAIL (ALTERNATE 1) PROPOSED BENCH CONCRETE PAD NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft.L1.01 WLM17000-LS1 - GLJ SEE DRAWINGS AREA A LANDSCAPE PLAN LIGHTING PANEL AND CONTROLS PARKING PLANTING AREA: 1,336 SF PARKING PLANTING AREA: 991 SF PARKING PLANTING AREA: 3,115 SF PARKING PLANTING AREA: 621 SF PARKING PLANTING AREA: 300 SF PARKING PLANTING AREA: 323 SF PARKING PLANTING AREA: 154 SF PARKING PLANTING AREA: 337 SF PARKING PLANTING AREA: 465 SF PARKING PLANTING AREA: 536 SF PARKING PLANTING AREA: 3,374 SF PARKING PLANTING AREA: 2,097 SF PARKING PLANTING AREA: 489 SF CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - L P 1 A . d w g , 4/ 2 7 / 2 0 2 1 1 : 3 8 : 0 5 P M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 KEY MAP N.T.S. L1.01 L1.03 L1.04 L1.04 L1.04 L1.02 EXISTING FIELD #1EXISTING FIELD #2EXISTING FIELD #3RENOVATED FIELD #4 FIELD #11 SYNTHETIC RENOVATED PARKING (ALTERNATE 4) RENOVATED PARKING (ALTERNATE 4) RENOVATED PARKING (ALTERNATE 4) SITE LEGENDLANDSCAPE HATCH LEGEND TREE LEGEND ALTERNATE 4: INSTALL INDICATED PLANTS IN THIS AREA. SEE SHEET L2.00 FOR SCHEDULE. SEE BASE BID LANDSCAPE PLAN, SHEET L2.01 FOR BASE BID CONDITIONS. ALTERNATE 1: INSTALL INDICATED PLANTS IN THIS AREA. SEE SHEET L2.00 FOR SCHEDULE. SEE BASE BID LANDSCAPE PLAN, SHEET L2.01 FOR BASE BID CONDITIONS. ALTERNATE 4: INSTALL INDICATED PLANTS IN THIS AREA. SEE SHEET L2.00 FOR SCHEDULE. SEE BASE BID LANDSCAPE PLAN, SHEET L2.01 FOR BASE BID CONDITIONS. ALTERNATE 1: INSTALL INDICATED PLANTS IN THIS AREA. SEE SHEET L2.00 FOR SCHEDULE. SEE BASE BID LANDSCAPE PLAN, SHEET L2.01 FOR BASE BID CONDITIONS. P5 P5 MATCHLINE - SEE SHEET L1.03 ADA PARKING RESTROOM BUILDING ±2,600 SF (SEE ARCH. DRAWINGS) MAINTENANCE BUILDING ±400 SF FOOD TRUCK PARKING 20' METHANE VENT CLEAR ZONE APPROX. LIMITS OF LANDFILL MATERIAL NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft.L1.02 WLM17000-LS1 - GLJ SEE DRAWINGS AREA B LANDSCAPE PLAN MATCHLINE - SEE SHEET L1.01 MATCHLINE - SEE SHEET L1.03 ENLARGEMENT - SEE SHEET L1.04 DUMPSTER PAD ALL SMOKETREES TO BE PLANTED IN 36" W X 36" H X 36" L PLANTERS SITE LEGEND ELECTRICAL TRANSFORMERS AND PANEL ELECTRICAL TRANSFORMERS AND PANEL BUILDING FOUNDATION PLANTING: 1,410 SF PARKING PLANTING AREA: 2,135 SF PARKING PLANTING AREA: 621 SF PARKING PLANTING AREA: 185 SF PARKING PLANTING AREA: 621 SF PARKING PLANTING AREA: 4,368 SF PARKING PLANTING AREA: 4,993 SF PARKING PLANTING AREA: 210 SF PARKING PLANTING AREA: 210 SF PARKING PLANTING AREA: 4,993 SF PARKING PLANTING AREA: 4,368 SF PARKING PLANTING AREA: 1,284 SF PARKING PLANTING AREA: 307 SF PARKING PLANTING AREA: 241 SF PARKING PLANTING AREA: 1,336 SF CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - L P 1 A . d w g , 4/ 2 7 / 2 0 2 1 1 : 3 8 : 2 3 P M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 KEY MAP N.T.S. L1.01 L1.03 L1.04 L1.04 L1.04 L1.02 FIELD #11 SYNTHETIC WALKING TRAIL (ALTERNATE 1) RENOVATED PARKING (ALTERNATE 4) EXISTING FIELD #5 EXISTING FIELD #10 FIELD #6 FIELD #8 WALKING TRAIL (ALTERNATE 1) ALTERNATE 4: INSTALL INDICATED PLANTS IN THIS AREA. SEE SHEET L2.00 FOR SCHEDULE. SEE BASE BID LANDSCAPE PLAN, SHEET L2.01 FOR BASE BID CONDITIONS. ALTERNATE 4: INSTALL INDICATED PLANTS IN THIS AREA. SEE SHEET L2.00 FOR SCHEDULE. SEE BASE BID LANDSCAPE PLAN, SHEET L2.01 FOR BASE BID CONDITIONS. LANDSCAPE HATCH LEGEND TREE LEGEND ALTERNATE 3: INSTALL INDICATED PLANTS IN THIS AREA. SEE SHEET L2.00 FOR SCHEDULE. SEE BASE BID LANDSCAPE PLAN, SHEET L2.01 FOR BASE BID CONDITIONS. ALTERNATE 1: INSTALL INDICATED PLANTS IN THIS AREA. SEE SHEET L2.00 FOR SCHEDULE. SEE BASE BID LANDSCAPE PLAN, SHEET L2.01 FOR BASE BID CONDITIONS. BOULDER (TYP.) L1.03 WLM17000-LS1 - GLJ SEE DRAWINGS AREA C LANDSCAPE PLAN MATCHLINE - SEE SHEET L1.02 PROPERTY LINE LEVEL SPREADER LEVEL SPREADER APPROX. LIMITS OF LANDFILL MATERIAL NC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. ALL TREES TO BE INCLUDED IN BASE BID (TYP.) ALL TREES TO BE INCLUDED IN BASE BID (TYP.) CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - L P 1 A . d w g , 4/ 2 7 / 2 0 2 1 1 : 3 8 : 3 4 P M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 KEY MAP N.T.S. L1.01 L1.03 L1.04 L1.04 L1.04 L1.02 SITE LEGEND FIELD #7 FIELD #9 WALKING TRAIL (ALTERNATE 1) FIELD #6 FIELD #8 LANDSCAPE HATCH LEGEND TREE LEGEND L1.04 WLM17000-LS1 - GLJ SEE DRAWINGS AREAS D, E, F LANDSCAPE PLANNC GRID (NAD83) GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. CONCRETE BENCH PAD (ALTERNATE 1) PROPOSED WALKING TRAIL (ALTERNATE 1) 11 PROPERTY LINE EXISTING FENCE PROPERTY LINE PROPERTY LINE CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - L P 1 A . d w g , 4/ 2 7 / 2 0 2 1 1 : 3 9 : 1 1 P M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 MATCHLINE - SEE SHEET C2.01 MA T C H L I N E - S E E S H E E T L 1 . 0 2 AREA D MATCHLINE - SEE SHEET L1.01 MA T C H L I N E - S E E S H E E T L 1 . 0 1 AREA E MA T C H L I N E - S E E S H E E T L 1 . 0 3 AREA F KEY MAP N.T.S. L1.01 L1.03 L1.04 L1.04 L1.04 L1.02 SITE LEGENDLANDSCAPE HATCH LEGEND TREE LEGEND P5 P5 L1.05 WLM17000-LS1 - GLJ 1" = 20' ENLARGEMENT LANDSCAPE PLANNC GRID (NAD83)NC GRID (NAD83) GRAPHIC SCALE 0 10 20 40 1 inch = 20 ft. SITE LEGEND NOTES 1.SEE SHEET L2.00 FOR LANDSCAPE NOTES, PLANT SCHEDULE, AND LANDSCAPE DETAILS. ADA PARKING RESTROOM BUILDING ±2,600 SF (SEE ARCH. DRAWINGS) FOOD TRUCK PARKING PLAYGROUND (ALT. 3) ELECTRICAL TRANSFORMERS AND PANEL ALTERNATE 3: INSTALL INDICATED PLANTS IN THIS AREA. SEE SHEET L2.00 FOR SCHEDULE. SEE BASE BID LANDSCAPE PLAN, SHEET L2.01 FOR BASE BID CONDITIONS. CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - L P 1 A . d w g , 4/ 2 7 / 2 0 2 1 1 : 3 9 : 2 5 P M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 FIELD #11 SYNTHETIC FIELD #6 BOULDER (TYP.) L2.00 WLM17000-LS1 - GLJ SEE DRAWINGS SCHEDULE + NOTES LANDSCAPE DETAILS, CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - L P 1 A . d w g , 4/ 2 7 / 2 0 2 1 1 : 3 9 : 2 9 P M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 SCALE:1/2"=1'-0" ORNAMENTAL GRASS INSTALLATION 04 SCALE:3/8"=1'-0" GROUNDCOVER INSTALLATION 02SCALE:3/8"=1'-0" SHRUB INSTALLATION 01 LANDSCAPE NOTES 1.ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY AND THE STATE OF NORTH CAROLINA STANDARDS AND SPECIFICATIONS. 2.CONTRACTOR IS RESPONSIBLE FOR THE SITE INSPECTION BEFORE LANDSCAPE CONSTRUCTION AND INSTALLATION IN ORDER TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS. 3.LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES BEFORE BEGINNING DEMOLITION OR INSTALLATION. 4.CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF ANY DISCREPANCIES BETWEEN THE NOTES, SPECIFICATIONS, DRAWINGS OR SITE CONDITIONS FOR RESOLUTION PRIOR TO INSTALLATION. 5.ANY DAMAGE TO UTILITIES SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. 6.THIS PLAN IS FOR PLANTING PURPOSES ONLY. FOR INFORMATION REGARDING BUILDINGS, GRADING, WALLS, ETC., REFER TO ARCHITECTURE, SITE AND GRADING PLANS. 7.VERIFICATION OF TOTAL PLANT QUANTITIES AS SHOWN IN THE PLANT SCHEDULE SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT. 8.CONTRACTOR TO ENSURE PROPER STABILIZATION AND SEEDING OF THE SITE IN ACCORDANCE WITH APPLICABLE REGULATIONS. 9.LANDSCAPE MATERIAL SHALL BE WELL FORMED, VIGOROUS, GROWING SPECIMENS WITH GROWTH TYPICAL OF VARIETIES SPECIFIED AND SHALL BE FREE FROM DAMAGE, INSECTS AND DISEASES. MATERIAL SHALL EQUAL OR SURPASS #1 QUALITY AS DEFINED IN THE CURRENT ISSUE OF “AMERICAN STANDARD FOR NURSERY STOCK” AS PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION. 10.ALL PLANT MATERIAL IS TO BE CAREFULLY HANDLED BY THE ROOT BALL, NOT THE TRUNK, BRANCHES AND/OR FOLIAGE OF THE PLANT. MISHANDLED PLANT MATERIAL MAY BE REJECTED BY THE LANDSCAPE ARCHITECT. 11.ALL PLANT MATERIAL IS TO BE WELL ROOTED, NOT ROOT BOUND, SUCH THAT THE ROOT BALL REMAINS INTACT THROUGHOUT THE PLANTING PROCESS. DEFICIENT PLANT MATERIAL MAY BE REJECTED BY THE LANDSCAPE ARCHITECT OR OWNER. 12.ALL PLANTS TO BE A MINIMUM OF WHAT IS SPECIFIED IN THE PLANT SCHEDULE. ANY CHANGES OR SUBSTITUTIONS SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT AND GOVERNING JURISDICTION PRIOR TO ANY HOLE BEING DUG. 13.CONTRACTOR TO COORDINATE WITH OWNER'S REPRESENTATIVE AND LANDSCAPE ARCHITECT TO ESTABLISH THE EXTENTS OF MULCH/SEED/SOD IF NOT SPECIFICALLY SHOWN ON PLANS. 14.CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE IN ALL PLANTING AREAS. 15.PROPOSED TREES TO BE PLANTED A MINIMUM 10 FEET FROM ANY LIGHT POLE AS MEASURED FROM TRUNK OF THE TREE TO THE POLE. 16.PROPOSED TREES TO BE PLANTED A MINIMUM 5 FEET FROM ANY FIRE HYDRANT AS MEASURED FROM TRUNK OF THE TREE TO THE HYDRANT. 17.CONTRACTOR SHALL COMPLETE SOIL TEST IN ALL PLANTING AREAS TO DETERMINE SOIL AMENDMENT REQUIREMENTS UNLESS WAIVED BY OWNER'S REPRESENTATIVE. CONTRACTOR SHALL ADJUST PH AND FERTILITY BASED UPON THE SOIL TEST RESULTS. 18.TOPSOIL SHALL BE FREE OF MATERIAL LARGER THAN 1.0 INCH IN DIAMETER OR LENGTH AND SHALL NOT CONTAIN SLAG, CINDERS, STONES, LUMPS OF SOIL, STICKS, ROOTS, TRASH, OR OTHER EXTRANEOUS MATERIAL. 19.LOOSEN SUBGRADE / SURFACE SOIL TO A MINIMUM DEPTH OF 6 INCHES. APPLY SOIL AMENDMENTS AND FERTILIZERS AS REQUIRED BY THE SOIL TEST RESULTS TO ACHIEVE A HEALTHY GROWING MEDIA AND MIX THOROUGHLY INTO TOP 4 INCHES OF SOIL. SPREAD PLANTING SOIL MIX TO A DEPTH OF 6 INCHES BUT NOT LESS THAN REQUIRED TO MEET FINISH GRADES AFTER NATURAL SETTLEMENT. DO NOT SPREAD IF PLANTING SOIL OR SUBGRADE IS FROZEN, MUDDY, OR EXCESSIVELY WET. 20.IF IMPORTED TOPSOIL IS REQUIRED, THE SUBGRADE SHALL BE SCARIFIED OR TILLED TO A DEPTH OF AT LEAST 6 INCHES PRIOR TO INSTALLATION OF IMPORTED TOPSOIL. FOLLOWING INSTALLATION OF IMPORTED TOPSOIL, THE TOPSOIL SHALL BE TILLED TO INTEGRATE THE SOIL PROFILES. 21.PLANT MATERIALS ARE TO BE GUARANTEED FOR A PERIOD OF 12 MONTHS. PLANT MATERIALS WHICH REMAIN UNHEALTHY WILL BE REPLACED BY THE LANDSCAPE CONTRACTOR BEFORE THE EXPIRATION OF THE GUARANTEE PERIOD OR IMMEDIATELY IF SO DIRECTED BY THE OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT. 22.ALL TREE PLANTINGS SHALL BE MULCHED TO A DEPTH OF 3 INCHES, AND WITH A MINIMUM 3 FOOT RADIUS FROM BASE OF TREE OR TO DRIPLINE. MULCH SHALL BE FREE OF TRASH AND MAINTAINED WEED FREE. MULCH SHALL NOT COVER THE ROOT FLARE. CONFIRM MULCH SPECIFICATIONS WITH OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT. 23.DO NOT PRUNE TREES AND SHRUBS BEFORE DELIVERY. PROTECT BARK, BRANCHES, AND ROOT SYSTEMS FROM SUN SCALD, DRYING, SWEATING, WHIPPING, AND OTHER HANDLING AND TYING DAMAGE. DO NOT BEND OR BIND-TIE TREES OR SHRUBS IN SUCH A MANNER AS TO DESTROY THEIR NATURAL SHAPE. PROVIDE PROTECTIVE COVERING OF EXTERIOR PLANTS DURING DELIVERY. DO NOT DROP EXTERIOR PLANTS DURING DELIVERY AND HANDLING. 24.DELIVER EXTERIOR PLANTS AFTER PREPARATIONS FOR PLANTING HAVE BEEN COMPLETED AND INSTALL IMMEDIATELY. IMMEDIATELY AFTER UNLOADING, STAND THE TREES UP TO REDUCE THE RISK OF SUN SCALD. PROPERLY STAGED TREES ARE STANDING, UNTIED AND SPACED. UNLESS IMMEDIATELY INSTALLED, SET EXTERIOR PLANTS AND TREES IN SHADE, PROTECT FROM WEATHER AND MECHANICAL DAMAGE, AND KEEP ROOTS MOIST. 25.SEE LANDSCAPE DETAILS FOR TREE STAKING REQUIREMENTS. 26.EXCAVATE EDGES OF ALL PLANTING BEDS TO 2 INCH DEPTH TO FORM A NEAT AND CRISP DEFINITION. 27.CONTRACTOR SHALL REMOVE DEBRIS AND FINE GRADE ALL PLANTING AREAS PRIOR TO INSTALLATION. 28.REMOVE GUY WIRES AND STAKES AT END OF WARRANTY PERIOD OR ESTABLISHMENT. 29.FINISH GRADING: GRADE PLANTING AREAS TO A SMOOTH, UNIFORM SURFACE PLANE WITH LOOSE, UNIFORMLY FINE TEXTURE. GRADE TO WITHIN PLUS OR MINUS 1/2 INCH OF FINISH ELEVATION. ROLL AND RAKE, REMOVE RIDGES, AND FILL DEPRESSIONS TO MEET FINISH GRADES. LIMIT FINISHED GRADING TO AREAS THAT CAN BE PLANTED IN THE IMMEDIATE FUTURE. SCALE:3/8"=1'-0" TREE INSTALLATION 05 SCALE:1 1/2"=1'-0" LANDSCAPE EDGING 06 SEED MIXES AND PLUGS SCALE:N.T.S. TREE ON SLOPE 5% (20:1) TO 50% (2:1) - MODIFIED SOIL 03 P5 P5 P5 P5 L2.01 WLM17000-LS1 - GLJ SEE DRAWINGS LANDSCAPE PLAN OVERALL BASE BIDNC GRID (NAD83) GRAPHIC SCALE 0 50 100 200 1 inch = 100 ft. CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - L P 1 - B B . d w g , 4/ 2 7 / 2 0 2 1 1 : 3 9 : 5 1 P M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 EXISTING SITE ENTRANCE RESTROOM BUILDING EXISTING GAZEBO EXISTING FENCE LINE GRAVEL PARKING LOT 10' CONCRETE SIDEWALK LEVEL SPREADER LEVEL SPREADER SITE LEGEND P R O P E R T Y L I N E EXISTING FIELD #10 EXISTING FIELD #5 FIELD #11 SYNTHETIC EXISTING FIELD #1 FIELD #9 FIELD #6 FIELD #8 P R O P E R T Y L I N E AREA A - SEE SHEET L1.01 10' CONCRETE SIDEWALK FIELD #7 FIELD LIGHTS FIELD LIGHTS AREA B - SEE SHEET L1.02 AREA C - SEE SHEET L1.03 PROPERTY LINE SEPTIC EXPANSION AREA EXTENTS EXISTING RIP RAP NOTES 1.SEE SHEET L2.02 FOR BASE BID LANDSCAPE NOTES AND SCHEDULE. 2.CONTRACTOR TO PLACE SOD ON AREAS DISTURBED DURING THE INSTALLATION OF ATHLETIC LIGHTS. SEE SPECIFICATIONS FOR SOD ALLOWANCE. 3.ALL TREES SHALL BE INCLUDED IN BADE BID. 4.THIS PLAN IS FOR REFERENCE ONLY. REFER TO THE OVERALL LANDSCAPE PLAN ON SHEET L1.00 FOR PROPOSED LANDSCAPE CONDITIONS SHOULD ALTERNATES, AS DEFINED ON SHEET C2.00, BE IMPLEMENTED. IMPLEMENTATION OF BASE BID AND ALL ALTERNATES REPRESENT FULL BUILD-OUT. MAINTENANCE BLDG. AND FENCE DUMPSTER PAD AREA D - SEE SHEET L1.04 AREA F - SEE SHEET L1.04 AREA E - SEE SHEET L1.04 EXISTING FIELD #2EXISTING FIELD #3RENOVATED FIELD #4 L2.02 WLM17000-LS1 - GLJ SEE DRAWINGS SCHEDULE + NOTES BASE BID LANDSCAPE LANDSCAPE NOTES 1.ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY AND THE STATE OF NORTH CAROLINA STANDARDS AND SPECIFICATIONS. 2.CONTRACTOR IS RESPONSIBLE FOR THE SITE INSPECTION BEFORE LANDSCAPE CONSTRUCTION AND INSTALLATION IN ORDER TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS. 3.LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES BEFORE BEGINNING DEMOLITION OR INSTALLATION. 4.CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF ANY DISCREPANCIES BETWEEN THE NOTES, SPECIFICATIONS, DRAWINGS OR SITE CONDITIONS FOR RESOLUTION PRIOR TO INSTALLATION. 5.ANY DAMAGE TO UTILITIES SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. 6.THIS PLAN IS FOR PLANTING PURPOSES ONLY. FOR INFORMATION REGARDING BUILDINGS, GRADING, WALLS, ETC., REFER TO ARCHITECTURE, SITE AND GRADING PLANS. 7.VERIFICATION OF TOTAL PLANT QUANTITIES AS SHOWN IN THE PLANT SCHEDULE SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT. 8.CONTRACTOR TO ENSURE PROPER STABILIZATION AND SEEDING OF THE SITE IN ACCORDANCE WITH APPLICABLE REGULATIONS. 9.LANDSCAPE MATERIAL SHALL BE WELL FORMED, VIGOROUS, GROWING SPECIMENS WITH GROWTH TYPICAL OF VARIETIES SPECIFIED AND SHALL BE FREE FROM DAMAGE, INSECTS AND DISEASES. MATERIAL SHALL EQUAL OR SURPASS #1 QUALITY AS DEFINED IN THE CURRENT ISSUE OF “AMERICAN STANDARD FOR NURSERY STOCK” AS PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION. 10.ALL PLANT MATERIAL IS TO BE CAREFULLY HANDLED BY THE ROOT BALL, NOT THE TRUNK, BRANCHES AND/OR FOLIAGE OF THE PLANT. MISHANDLED PLANT MATERIAL MAY BE REJECTED BY THE LANDSCAPE ARCHITECT. 11.ALL PLANT MATERIAL IS TO BE WELL ROOTED, NOT ROOT BOUND, SUCH THAT THE ROOT BALL REMAINS INTACT THROUGHOUT THE PLANTING PROCESS. DEFICIENT PLANT MATERIAL MAY BE REJECTED BY THE LANDSCAPE ARCHITECT OR OWNER. 12.ALL PLANTS TO BE A MINIMUM OF WHAT IS SPECIFIED IN THE PLANT SCHEDULE. ANY CHANGES OR SUBSTITUTIONS SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT AND GOVERNING JURISDICTION PRIOR TO ANY HOLE BEING DUG. 13.CONTRACTOR TO COORDINATE WITH OWNER'S REPRESENTATIVE AND LANDSCAPE ARCHITECT TO ESTABLISH THE EXTENTS OF MULCH/SEED/SOD IF NOT SPECIFICALLY SHOWN ON PLANS. 14.CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE IN ALL PLANTING AREAS. 15.PROPOSED TREES TO BE PLANTED A MINIMUM 10 FEET FROM ANY LIGHT POLE AS MEASURED FROM TRUNK OF THE TREE TO THE POLE. 16.PROPOSED TREES TO BE PLANTED A MINIMUM 5 FEET FROM ANY FIRE HYDRANT AS MEASURED FROM TRUNK OF THE TREE TO THE HYDRANT. 17.CONTRACTOR SHALL COMPLETE SOIL TEST IN ALL PLANTING AREAS TO DETERMINE SOIL AMENDMENT REQUIREMENTS UNLESS WAIVED BY OWNER'S REPRESENTATIVE. CONTRACTOR SHALL ADJUST PH AND FERTILITY BASED UPON THE SOIL TEST RESULTS. 18.TOPSOIL SHALL BE FREE OF MATERIAL LARGER THAN 1.0 INCH IN DIAMETER OR LENGTH AND SHALL NOT CONTAIN SLAG, CINDERS, STONES, LUMPS OF SOIL, STICKS, ROOTS, TRASH, OR OTHER EXTRANEOUS MATERIAL. 19.LOOSEN SUBGRADE / SURFACE SOIL TO A MINIMUM DEPTH OF 6 INCHES. APPLY SOIL AMENDMENTS AND FERTILIZERS AS REQUIRED BY THE SOIL TEST RESULTS TO ACHIEVE A HEALTHY GROWING MEDIA AND MIX THOROUGHLY INTO TOP 4 INCHES OF SOIL. SPREAD PLANTING SOIL MIX TO A DEPTH OF 6 INCHES BUT NOT LESS THAN REQUIRED TO MEET FINISH GRADES AFTER NATURAL SETTLEMENT. DO NOT SPREAD IF PLANTING SOIL OR SUBGRADE IS FROZEN, MUDDY, OR EXCESSIVELY WET. 20.IF IMPORTED TOPSOIL IS REQUIRED, THE SUBGRADE SHALL BE SCARIFIED OR TILLED TO A DEPTH OF AT LEAST 6 INCHES PRIOR TO INSTALLATION OF IMPORTED TOPSOIL. FOLLOWING INSTALLATION OF IMPORTED TOPSOIL, THE TOPSOIL SHALL BE TILLED TO INTEGRATE THE SOIL PROFILES. 21.PLANT MATERIALS ARE TO BE GUARANTEED FOR A PERIOD OF 12 MONTHS. PLANT MATERIALS WHICH REMAIN UNHEALTHY WILL BE REPLACED BY THE LANDSCAPE CONTRACTOR BEFORE THE EXPIRATION OF THE GUARANTEE PERIOD OR IMMEDIATELY IF SO DIRECTED BY THE OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT. 22.ALL TREE PLANTINGS SHALL BE MULCHED TO A DEPTH OF 3 INCHES, AND WITH A MINIMUM 3 FOOT RADIUS FROM BASE OF TREE OR TO DRIPLINE. MULCH SHALL BE FREE OF TRASH AND MAINTAINED WEED FREE. MULCH SHALL NOT COVER THE ROOT FLARE. CONFIRM MULCH SPECIFICATIONS WITH OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT. 23.DO NOT PRUNE TREES AND SHRUBS BEFORE DELIVERY. PROTECT BARK, BRANCHES, AND ROOT SYSTEMS FROM SUN SCALD, DRYING, SWEATING, WHIPPING, AND OTHER HANDLING AND TYING DAMAGE. DO NOT BEND OR BIND-TIE TREES OR SHRUBS IN SUCH A MANNER AS TO DESTROY THEIR NATURAL SHAPE. PROVIDE PROTECTIVE COVERING OF EXTERIOR PLANTS DURING DELIVERY. DO NOT DROP EXTERIOR PLANTS DURING DELIVERY AND HANDLING. 24.DELIVER EXTERIOR PLANTS AFTER PREPARATIONS FOR PLANTING HAVE BEEN COMPLETED AND INSTALL IMMEDIATELY. IMMEDIATELY AFTER UNLOADING, STAND THE TREES UP TO REDUCE THE RISK OF SUN SCALD. PROPERLY STAGED TREES ARE STANDING, UNTIED AND SPACED. UNLESS IMMEDIATELY INSTALLED, SET EXTERIOR PLANTS AND TREES IN SHADE, PROTECT FROM WEATHER AND MECHANICAL DAMAGE, AND KEEP ROOTS MOIST. 25.SEE LANDSCAPE DETAILS FOR TREE STAKING REQUIREMENTS. 26.EXCAVATE EDGES OF ALL PLANTING BEDS TO 2 INCH DEPTH TO FORM A NEAT AND CRISP DEFINITION. 27.CONTRACTOR SHALL REMOVE DEBRIS AND FINE GRADE ALL PLANTING AREAS PRIOR TO INSTALLATION. 28.REMOVE GUY WIRES AND STAKES AT END OF WARRANTY PERIOD OR ESTABLISHMENT. 29.FINISH GRADING: GRADE PLANTING AREAS TO A SMOOTH, UNIFORM SURFACE PLANE WITH LOOSE, UNIFORMLY FINE TEXTURE. GRADE TO WITHIN PLUS OR MINUS 1/2 INCH OF FINISH ELEVATION. ROLL AND RAKE, REMOVE RIDGES, AND FILL DEPRESSIONS TO MEET FINISH GRADES. LIMIT FINISHED GRADING TO AREAS THAT CAN BE PLANTED IN THE IMMEDIATE FUTURE. 30.SEE SHEET L2.00 FOR LANDSCAPE DETAILS CLIENT REVISIONS PROJECT NO.WLM-17000 FILENAME CHECKED BY DRAWN BY SCALE DATE N0.DATE X: \ P r o j e c t s \ _ S h a r e d \ W L M \ W L M - 1 7 0 0 0 \ 0 4 - P r o d u c t i o n \ E n g i n e e r i n g \ C o n s t r u c t i o n D r a w i n g s \ C u r r e n t D r a w i n g s \ W L M 1 7 0 0 0 - L P 1 - B B . d w g , 4/ 2 7 / 2 0 2 1 1 : 3 9 : 5 5 P M , Je n k i n s , G a r r e t t The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com SHEET PLAN INFORMATION CITY OF WILMINGTON 305 CHESTNUT STREET, 5TH FLOOR WILMINGTON, NC 28402 PHONE: 910. 341. 7830 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION RE G I O N A L A T H L E T I C C O M P L E X SI T E P L A N S U B M I T T A L 20 5 S U T T O N S T E A M P L A N T R O A D WI L M I N G T O N , N C 2 8 4 0 1 04.27.2021 SEED MIXES AND PLUGS