Loading...
00_Goldenberg Family Office_TRC Comments Response Letter with Attachments (2)                August 20, 2021  M&C 08249‐0001 (40)    Ron Meredith, Current Planner  New Hanover County  Planning & Land Use  230 Government Center Drive, Suite 110  Wilmington, North Carolina 28403    RE: Goldenberg Office – TRC Review Comment Response   6005/6007 Market Street, Wilmington, NC    Dear Ron:  In response to the TRC comments received in regards to the Goldenberg Office  Building, we offer the following responses:   Ron Meredith, Current Planner  TRC Planning Review Comments (2021‐07‐02)    1. Please update the plan with the following general corrections:  a. General comments per the Major Site Plan application.  i. Please provide a copy of the site plan with the Engineer’s seal.  Response: Sealed plans are included with this resubmittal.    ii. Please provide the land use and zoning of the adjacent parcels.  Response: Refer to sheet CX‐100 for all adjacent parcel labels,  including land use and zoning.    iii. Please provide a legend for all symbols used within the site plan.  Response: Noted.    iv. Please be sure that all elevations are tied to North  American Vertical Datum of 1988 (NAVD 88) and  horizontal coordinates must be tied to the North  Carolina Grid System.   Response: Confirmed. A copy of the boundary and topographic  survey that was completed is included with this resubmittal.    Mr. Ron Meredith, Current Planner  New Hanover County Planning and Land Use   July 27, 2021  Page 2    v. Please indicate the location of all environmental  areas of concern including conservation resources,  404 wetlands, and 401 wetlands as defined by the  appropriate agency.  Response: The site is located in an “Urban” land  classification per the attached 2006 CAMA Plan. The  boundary and topographic survey that was  completed did not include wetlands identification.  However, the attached exhibit from the U.S. Fish  and Wildlife Service shows the project site “does  not” contain any wetlands.    vi. Please include all existing and proposed  landscaping, including caliper, height, and species  that will be preserved or installed to comply with  the landscaping requirements including bufferyard,  streetscape, foundation, screening, and parking lot  landscaping.  Response: Please refer to separately submitted  landscape plan designed by Mihaly Land Design.     b. It appears there are City of Wilmington references on the  General Notes sheet, please work with NHC Engineering and  the CFPUA to determine what notes are required.  Response: Noted. The General Notes Sheet has been updated  to include the appropriate information.    c. Please hatch the existing parking for clarity.  Response: The existing parking lot for the ABC Headquarters building is  shown on the plans and is grayed back to identify that it’s existing.     d. Please show and label the sight triangles on the landscape and site plan.  Response: Sight triangles are not applicable to this site. The driveway for  this property connects to a shared access drive and not the right of way.      e. Please show and label the setbacks on the site plan.  Response: Refer to sheet CS‐101 for the setbacks shown with labels.    f. Please adjust the label for the square footage of the interior  parking island, it appears the label is on top of the GPS nail  label.  Response: Could not locate this labeling conflict on the plans.  Mr. Ron Meredith, Current Planner  New Hanover County Planning and Land Use   July 27, 2021  Page 3        2. Screening:  a. Please provide screening, UDO Section 5.4.4, heating/air  conditioning units are to be shielded from view from the  property line of an existing residential use by a 100 percent  opaque solid wall.  Response: The Architect is aware of this requirement and is  working with the mechanical engineers on proper screening to  meet this condition for all units located on the roof.     3. Please indicate the location of signage to comply with UDO Section 5.  Response: The only exterior signage for this building will be  an address at the entry gate.     4. Please label the buffer as a Type A Opaque Buffer.  Response: This information was added to Sheet CS‐101.    5. Landscape Plan:  a. Please provide a landscape plan.  Response: The landscape plan will be submitted separately by  Mihaly Land Design.      6. Tree Retention:  b. Please be aware that there are optional incentives for  retaining trees on site, UDO Section 5.3.8.A.2.  Response: Noted.     c. The tree retention standards have recently been updated.  Please provide the specific species (Loblolly pine, Long  Leaf pine, etc.) of all regulated trees to be removed or  credited for mitigation. In addition to the significant trees,  please list all regulated trees to be removed.  Response: Refer to the included Tree Removal Permit and Tree  Removal List for the list of all trees to be removed, their size  and classification of Documented or Significant. No significant  trees are proposed for removal; therefore, no mitigation is  required.      d. Per UDO Section 5.3.4.C, of the UDO requires a minimum  of 15 trees at least 2” DBH must be retained or planted on  the parcel where development occurs for each acre or  Mr. Ron Meredith, Current Planner  New Hanover County Planning and Land Use   July 27, 2021  Page 4    proportionate area disturbed.  i. Please note that required landscaping for the project can be  credited to meet this requirement.  Response: Noted. The forthcoming Landscape Plan will be  submitted separately, by Mihaly Land Design.     e. Please be aware that a Tree Removal Permit is required  prior to any land disturbance activities. Please provide the  specific species (Loblolly Pine, Long Leaf Pine, etc.) of the  trees to be removed or retained to determine required  mitigation.  Response: Noted. The required Tree Removal Permit has  been submitted. Refer to Sheet CD‐100 for tree removal  locations and refer to Tree Removal List for specific tree  species and size of trees proposed for removal.     f. Per UDO Section 5.3.6.B, please be aware that prior to any  construction activity protection fencing is required around  protected trees or tree stands. The fencing shall be a  minimum of four feet and shall remain in place through  completion of construction activities.  Response: Noted. Refer to Sheet CE‐101 for the location of  all Tree Protection Fencing. Refer to Sheet CE‐501 for Tree  Protection Fencing details.    7. Please be aware that no building permit will be issued until NCDOT has  issued the Driveway Permit.  Response: Comment not applicable, per Ron Meredith on TRC Teams  call.    8. UDO Section 5.5.3, before the Site Plan approval can be issued,  documentation must be provided to illustrate that street lighting, all  exterior lighting, and indoor lighting visible from outside shall be  designed and located so that the maximum illumination measured in foot  candles at ground level at lot lines abutting R‐15 parcels do not surpass  0.5.  Response: An exterior lighting plan is still under design. We  will provide a copy of the plan as soon as it’s complete.     9. Parking:  10. Offices for the Private Business and Professional Activities use requires  2.5 spaces per 1,000 sf. At 16,000 square feet, the proposed building  Mr. Ron Meredith, Current Planner  New Hanover County Planning and Land Use   July 27, 2021  Page 5    would require more parking than what has been proposed.  Section 5.1.3 does give options to provide an alternative parking plan to  allow for reduced parking.  Response: There will be 11 office spaces available in this  building. However, the owner is only expecting maybe 40%  of the available space to be occupied at any given time.  Typically, it will be much less than that. We are providing  12 marked spaces, which includes the handicapped  parking, as well as 7 unmarked spaces for additional  parking. This appears to be more than enough for the use of  this building. Additionally, unannounced visitors are not  anticipated as this a family office with a secured access gate.    11. Access:  a. Please provide a title opinion to show legal access through  the adjacent properties parking lot.  Response: Please review the attached legal documentation  provided by the Owner’s title insurance company.     b. It appears that the deed reference for the access easement  has been covered by the other text. Please adjust  accordingly.  Response: The text location on the plan was adjusted so  that it is now legible.    12. Easements:  a. Easements:  i. UDO Section 6.2.2, please label Storm Sewer, Sanitary  Sewer, and Water Main Utility Easements.  Response: The utility easement is shown and labeled on the Site Plans,  Sheets CS‐100 and CS‐101. We have also added this information to the  Utilities Plan for additional clarity.     Fire Services, Ray Griswold 910‐798‐7464  1. Fire hydrant placement shall be within 100 feet of the FDC  Response: The proposed Utilities Plan has the FDC located remotely from  the building with a hydrant in proximity. (See Sheet CU‐101)    2. I have reviewed the Fire Protection Notes. They are all  approved. However, this is a County Project. All statements  about Wilmington Fire shall reflect back to New Hanover  County Fire Services. The correct phone numbers are 910‐ Mr. Ron Meredith, Current Planner  New Hanover County Planning and Land Use   July 27, 2021  Page 6    798‐7463 ‐ New Hanover County Building Safety or 910‐798‐ 7420 New Hanover County Fire Services.  Response: The Fire Protection Notes have been updated and  now refer to New Hanover County Fire Services.    NHC Engineering (Stormwater), Galen Jamison 910‐798‐7142  1. Although the project appears to disturb less than one acre, the  proposed site is within an existing grading permit and will  therefore be required to obtain an erosion control permit.  Please submit for permit as the design is completed.  Response: Noted and will provide under separate submittal.    2. A land disturbing permit and a modification to the stormwater  system authority to construct (ATC #592‐11/18/13) is required  for this project. Please submit for permits as the design is  completed.  Response: Noted and will provide under separate submittal.    3. The site plan component checklist requirement for storm  pipes, drainage features and stormwater management features  isn’t provided and it is assumed the drainage will  conveyed/piped to the offsite permitted pond. If so, an  operation and maintenance agreement with the offsite parcel  will be required.  Response: Noted and will provide a completed O&M  agreement.    4. Documentation that the existing pond has adequate  capacity/volume will be required with the completion  certification of the stormwater ATC to verify previous pond  maintenance and ensure permitted volumes still exists.  Response: The existing stormwater wet pond was designed to  treat and control future impervious allocations for the parcels  that will have site improvements. We will provide updated  calculations showing adequate capacity under a separate  submittal.    5. If there is any offsite drainage routed through or around the  site or onsite drainage exiting the site with inadequate  conveyance/outfall, a drainage easement to assist with the  mission of new Stormwater Services department starting in  July may be required. Construction of offsite drainage  Mr. Ron Meredith, Current Planner  New Hanover County Planning and Land Use   July 27, 2021  Page 7    conveyance measures that will be maintained by the County  will need to observed by Stormwater Services and a turnover  meeting scheduled once the system is ready to be conveyed to  the County.  Response: Noted. None of the conditions referenced appear to  be present on this site.     Cape Fear Public Utility Authority, Bernice Johnson 910‐332‐6620  1. CFPUA plan review required.  Response: We have already coordinated with CFPUA on the preliminary  layout of utilities. We will be making a formal submittal for commercial plan  review.     2. CFPUA water and sewer available.  Response: Noted.    3. CFPUA Meter Sizing Form will be required.  Response: The Water Meter Sizing Form is currently under review by the  plumbing engineers. As soon as it’s complete, we will forward on to CFPUA  for review and approval.    NCDOT, Patrick Wurzel, 910‐398‐9100  1. We do not have any comments.  Response: Noted.    Environmental Health, Marie Hemmen 910‐798‐6664  1. Property will be tying onto sewer and water with CFPUA  Response: This is correct.    2. It does not appear that proposed building plans will affect adjacent lot septic  systems and wells.  Response: Noted.    WMPO, Scott James 910‐341‐7890  1. NCDOT Projects:  a. Tip Projects in the Area: U – 4902 C  b. Project Description: NORTH OF US 117/NC 132 (COLLEGE ROAD)  TO STATION ROAD).  c. Construction Date: Right‐of‐Way in progress, 2029  2. WMPO 2045 Projects:  a. N/A  3. New Hanover County CTP:  Mr. Ron Meredith, Current Planner  New Hanover County Planning and Land Use   July 27, 2021  Page 8    a. N/A  4. TIA: A TIA will not be required based on the following trip generation:    Response: All of the items above are noted.    Planning (Addressing), John Townsend 910‐798‐7443  1. Address will be 440 Judges Rd  Response: Noted and have added this information to the plans.    2. If suites or units are planned contact planning for address assignment  Response: This is currently not part of the plan for this building.         If you have any questions, please do not hesitate to contact me at our office 910‐ 343‐1048.    Sincerely,    McKIM & CREED, INC.    Brock Daniel  Senior Designer  N/ F RO G E R O . L A Z O A N D W I F E , CL E L I A Y . S A N T O S P O R T I L L O DE E D B O O K 5 9 4 1 P A G E 2 8 2 1 N/ F JU D G E S R O A D S T O R A G E L L C DE E D B O O K 6 2 2 0 P A G E 7 2 3 N/ F SA M R . J U D G E DE E D B O O K 9 1 3 P A G E 4 1 0 N/ F MA R I E R O B I N S O N D E V A N E DE E D B O O K 1 1 6 2 P A G E 1 9 0 2 N/ F ME N T A L P R O P E R T I E S L L C DE E D B O O K 5 4 4 6 P A G E 7 4 3 N/FMICHAEL BLAIN BAUGUS, AND WIFE BRENDA STALLINGS BAUGUS DEED BOOK 1636 PAGE 1185 N/F ROBERT DOROSKO DEED BOOK 6246 PAGE 288 N/F GRETCHEN HOLLEMAN DEED BOOK 5144 PAGE 2701 N/F ELIZABETH PEPPER DEED BOOK 4882 PAGE 1813 N/F TRENT T. & JULIA K. MOBLEY DEED BOOK 6368 PAGE 1673 N/F ROBERT VINCENT ALFARO & CHRISTINA R. ALFARO DEED BOOK 5535 PAGE 1700 N/F LESLIE R. SINGLETON DEED BOOK 6043 PAGE 1096 N/F CHARLES M. KROGER, & WIFE PATRICIA A. KROGER DEED BOOK 5271 PAGE 1980 N/F SKEJEA HOLDINGS LLC DEED BOOK 5901 PAGE 2350 N/ F TR I A N G L E G R O U P H O L D I N G S L L C DE E D B O O K 5 9 5 0 P A G E 3 6 2 N/ F TR A C Y P R O P E R T I E S L L C DE E D B O O K 5 1 1 2 P A G E 2 3 9 N/ F DA N I E L B . T R A C Y DE E D B O O K 5 1 1 2 P A G E 2 3 9 RBC #1001 NC GRID NAD83/2011 N 185264.59 GRID E 2346317.72 GRID EL. 38.87 RBC #1002 NC GRID NAD83/2011 N 185626.04 GRID E 2346109.37 GRID EL. 40.22 1" IPF 1" BENT PIPE 1" PIPE 1" COVERED PIPE1" PIPE1" PINCHED PIPE 1" PIPE 1" PIPE MAG NAIL FOUND GAS FINK FIBER OPTICMARKER 15" RCP FES INV. EL. 34.04 15" RCP FES INV. EL. 33.53 CURB INLET RIM. EL. 35.76INV. EL. 32.14 (NE) INV. EL. 32.17 (SE) CURB INLETRIM. EL. 35.78 INV. EL. 32.34 (NW) CURB INLET RIM. EL. 37.95INV. EL. 34.36 (NW) INV. EL. 34.43 (NE) CURB INLET RIM. EL. 38.18INV. EL. 34.53 (SW) CURB INLET RIM. EL. 38.40 INV. EL. 34.89 (SE) INV. EL. 35.00 (NW) CURB INLETRIM. EL. 38.99 INV. EL. 32.78 (NW) INV. EL. 32.90 (SE) CURB INLET RIM. EL. 39.03 INV. EL. 32.58 (SW) INV. EL. 32.68 (NE) CURB INLETRIM. EL. 39.09 INV. EL. 33.41(NE) INV. EL. 32.49 (SW) WATER HOSE DUMPSTER AREA LOT 1RR PLAT BOOK 69 PAGE 60 LOT 2R PLAT BOOK 61 PAGE 197 LOT 3 PLAT BOOK 50 PAGE 259 J U D G E S R O A D (60' PUBLIC RIGHT OF WAY) BUILDING BUILDING BUILDING 20 ' A T & T E A S E M E N T P E R DE E D B O O K 1 9 1 3 P A G E 4 0 6 10.0'10.0' 40 ' A C C E S S E A S E M E N T PE R P L A T B O O K 5 9 P A G E 2 5 7 55' UTILITY & ACCESS EASEMENT PER PLAT BOOK 59 PAGE 257 27. 5 ' 27. 5 ' NE W H A N O V E R C O U N T Y L I N E CI T Y O F W I L M I N G T O N L I N E AB A N D O N E D 1 2 5 ' C S X RA I L R O A D E A S E M E N T P E R DE E D B O O K 1 9 1 3 P A G E 4 0 6 LOT 4 PLAT BOOK 69 PAGE 60 N25°30'43"W 45.00' N6 4 ° 3 8 ' 2 2 " E 1 4 9 . 9 8 ' N25°31'30"W 300.05'N25°31'30"W 400.00' N6 4 ° 3 0 ' 0 4 " E 3 9 5 . 2 4 ' N25°21'38"W 27.50' N6 4 ° 3 0 ' 0 4 " E 7 3 . 5 4 ' N03°0 9 ' 2 6 " W 3 4 5 . 8 3 ' N24°37'56"W 375.50' N24°37'56"W 55.27' S6 4 ° 2 9 ' 4 6 " W 3 4 1 . 8 1 ' S25°30'14"E 430.72'S25°30'14"E 347.34' S6 4 ° 3 8 ' 2 2 " W 1 2 3 . 2 5 ' C1 S 5 0 ° 5 8 ' 2 8 " W 4 7 . 2 7 ' C2 S6 4 ° 2 9 ' 4 6 " W 7 0 . 8 7 ' SDMH RIM. EL. 40.24INACCESSIBLE BY CONCRETE DROP INLET RIM. EL. 35.96 INV. EL. 30.37 (SE) INV. EL. 30.42 (NW) DROP INLET RIM. EL. 35.93 INV. EL. 29.41(SE) INV. EL. 29.85 (NW) CURB INLET RIM. EL. 35.70 INV. EL. 29.57 (NW) INV. EL. 29.35 (SW) INV. EL. 29.10 (SE) SDMH RIM. EL. 36.80 INV. INACCESSIBLE 36" PIPE RUNS THROUGH MANHOLE 36" RCPINV. EL. 28.07 CURB INLET RIM. EL. 39.15 INV. EL. 30.36 (NE) INV. EL. 30.44 (SW) 15" RCP CURB INLET RIM. EL. 38.23 INV. EL. 30.84 (SW) INV. EL. 30.89 (SE) INV. EL. 30.89 (NW) INV. EL. 30.84 (NE) CURB INLET RIM. EL. 39.62 INV. EL. 34.52 (SE) SDMHRIM. EL. 40.65 INV. EL. 33.91 (SE) SANITARY MANHOLE RIM. EL. 39.14 INV. EL. 38.26INV. EL. 38.20 (NW) SANITARY MANHOLE RIM. EL. 40.53 INV. EL. 35.21 (SE) INV. EL. 35.14 (N) SANITARY MANHOLE RIM. EL. 47.36 INV. EL. 33.87 INV. EL. 33.87 SANITARY MANHOLE RIM. EL. 43.90 INV. EL. 33.39 (SW) INV. EL. 33.38 (NW) SANITARY MANHOLE RIM. EL. 39.57INV. EL. 32.48 (SE) INV. EL. 30.77 INV. EL. 30.69 8 6 6 6 18 21 16 14 8 12 78 12 12 3TREEX8 8 15 9 9 9 8 14 18 11 12 18 16 17 16 16 15 16181213 12 18 20 18 15 16 12 812812 12 1212121517 17 16 12 12 12 12 13 12 9 9 12 12 12 8 12 14 15 16 9 18 16 12248 14 16 12 12 12 24 16 14 8 10 12 10 8 8 14 15 12 8 14 9 8 10 9 88 8 88 9 8 10 14 9 8 8 10816 12119 9 9 9 10 9 9 16 8 8 8 15 8 TWIN 98 9 8 8 15 16 8 TWIN 14 1612 14 13 12 14 8 14 1314 18 12 1213 TRIPLE 16 12 10 12 16 1214 5 8 12 910 9 10 8 1213 8 TWIN 12 12 12 8 1713 9 99 10 TWIN 8 16 913 1613 13 13 12 16 12 8 9 19 65 12 12 135 13 11 88 141588101420 24 99 18 9 13 8 10 8 10 8 TWIN 8 8 8 88 15 9 13 TRIPLE 8 8 22 9 9 22 101310 8 19 20 9 13 9 8 12 12 20 8 ELECTRIC PANEL ELECTRIC BOX GATE GATE 8' HIGH CHAIN LINK FENCE ALONG PROPERTY LINE DROP INLET RIM. EL. 39.35INV. EL. 31.87 (N) INV. EL. 31.87 (SW) DROP INLET RIM. EL. 39.09 INV. EL. 35.97 (NE) DROP INLET RIM. EL. 38.90 INV. EL. 31.35 (NE) INV. EL. 31.31 (S) INV. EL. 31.51 (SW) INV. EL. 31.36 (NW) 6' HIGH WOOD FENCE ALONG PROPERTY LINE N25°30'43"W 224.05' 89,784 SQ. FT. 2.06 ACRES 145,813 SQ. FT. 3.35 ACRES 102,947 SQ. FT. 2.36 ACRES 67,741 SQ. FT. 1.56 ACRES CURB INLET RIM. EL. 38.77 INV. EL. 35.04 (SW) 8' HIGH CHAIN LINK FENCE ALONG PROPERTY LINE N6 4 ° 2 9 ' 4 5 " E 3 3 5 . 2 6 ' S6 5 ° 2 2 ' 0 4 " W 1 8 9 . 1 7 ' N29°57'41"W 417.20' 320.00'55.50' 30 " R C P 15 " R C P 15" RCP 15" RCP 18 " R C P 15 " R C P 15" RCP 18" RCP 24" R C P 18" RCP 30" R C P 24 " R C P 30" RCP 36" RCP 36" RCP 36" RC P36" RCP 36" RC P 24 " R C P 10' UTILITY EASEMENT PER PLAT BOOK 59 PAGE 257 N08°24'17"E 29.54' NCGS MONUMENT CAMA AZ MK NC GRID NAD83/2011 N 184116.71 GRID E 2345260.18 GRID ( T I E ) N 4 2 ° 3 9 ' 1 6 " E 1 5 6 0 . 7 8 ' S27°12'38"E 186.25' CLEANOUT BOLLARD (TYPICAL) S25°30'14"E 188.74' 60 . 0 ' N/ F NE W H A N O V E R C O U N T Y AB C B O A R D DE E D B O O K 5 7 1 9 P A G E 2 0 7 1 N/ F NE W H A N O V E R C O U N T Y AB C B O A R D DE E D B O O K 5 7 1 9 P A G E 2 0 7 1 8" PVC8" PVC 8" PV C 8" P V C 8" PVC 36 " R C P CONCRETE STRUCTURE GAS VAVLE CURVE TABLE CURVE C1 C2 RADIUS 215.00' 185.00' LENGTH 51.28' 43.66' TANGENT 25.76' 21.93' BEARING S57°48'25"W S57°44'07"W CHORD 51.16' 43.56' DELTA ∆ 13°39'58" 13°31'20" SHEET 1 OF 1 FAX: (910) 251-8282 TELEPHONE: (910) 343-1048 WILMINGTON, NORTH CAROLINA 28401 243 NORTH FRONT STREET NORTH CAROLINA FIRM LICENSE NUMBER: F-1222 BOUNDARY & TOPOGRAPHIC SURVEY FOR NEW HANOVER COUNTY ABC BOARD ABC OUT-PARCELS COMMERCIAL DEVELOPMENT CLIENT: 6005 MARKET STREET LLC CITY OF WILMINGTON, NEW HANOVER COUNTY, NORTH CAROLINA FEBRUARY 10, 2021 2021- NOTES: SURVEYOR'S CERTIFICATION: N S W E NC GRID NAD 83/2011 TREE LEGEND CARDINAL DR. MLK JR. PK W Y ELISHA DR. JUDGE ROAD MA R K E T S R E E T HARLEY DR. EAST W O O D R D . SITE LEGEND RBC 2006 Wilmington - New Hanover County CAMA Plan Land Classifcation Map Update Atlantic Ocean ÊBrunswick County Pender County Pender County 0 1 2 30.5 Miles 2006 CAMA Plan Update Land Classification Map 2006 Urban Service Boundary Conservation Area Natual Heritage Resource Protection Area Aquifer Resource Protection Area Watershed Resource Protection Wetland Resource Protection Area Urban Transition Community Rural Not in Planning Area wilmington.GISADMIN.parcels work.GISADMIN.StreetsMar2007 Goldenberg Office Site Source: Esri, Maxar, GeoEye, Earthstar Geographics, CNES/Airbus DS,USDA, USGS, AeroGRID, IGN, and the GIS User Community Wetlands Estuarine and Marine Deepwater Estuarine and Marine Wetland Freshwater Emergent Wetland Freshwater Forested/Shrub Wetland Freshwater Pond Lake Other Riverine July 27, 2021 0 0.1 0.20.05 mi 0 0.15 0.30.075 km 1:7,218 This page was produced by the NWI mapperNational Wetlands Inventory (NWI) This map is for general reference only. The US Fish and Wildlife Service is not responsible for the accuracy or currentness of the base data shown on this map. All wetlands related data should be used in accordance with the layer metadata found on the Wetlands Mapper web site.