HomeMy WebLinkAboutILM Cold Storage Facility PlansILM COLD STORAGE FACILITY
WILMINGTON INTERNATIONAL AIRPORT
SCALE: 1" = 100'LOCATION MAP2 SHEET INDEX1PROJECT INFORMATION3
SCALE: NOT TO SCALEVICINITY MAP4
IL
M
C
O
L
D
S
T
O
R
A
G
E
F
A
C
I
L
I
T
Y
08
8
7
9
-
0
0
0
3
NAME:
ILM COLD STORAGE FACILITY
CONTRACTOR:
EVANS GENERAL CONTRACTORS, LLC
4509 CREEDMOOR ROAD, SUITE 401
RALEIGH, NC 27612
ENGINEER: MCKIM & CREED, INC
243 N. FRONT ST. WILMINGTON, NC 28401
PHONE: 910.343.1048
RICHARD A. MOORE, PE
RAMOORE@MCKIMCREED.COM
SURVEYOR: MCKIM & CREED, INC
243 N. FRONT ST. WILMINGTON, NC 28401
PHONE: 910.343.1048
CHAD BURCHETTE, PLS
CBURCHETTE@MCKIMCREED.COM
PERMIT DRAWINGS
07/27/2022
07
/
0
8
/
2
0
2
2
PROPOSED
COLD STORAGE
FACILITY SITE
MARTIN
LUTHER KING
JR PARKWAY
NORTH 23RD
STREET
ILM INTERNATIONAL AIRPORT
AIRPORT
BOULEVARD
ISOLATED
WETLAND
GORDO
N
R
D
BL
U
E
C
L
A
Y
R
D
2
3
R
D
S
T
CA
S
T
L
E
H
A
Y
N
E
R
D
MA
R
T
I
N
L
U
T
H
E
R
KI
N
G
J
R
P
K
Y
KER
R
A
V
E
PROPOSED
STOCKPILE SITE
CURRENT
STOCKPILE SITE
I
L
M
A
I
R
P
O
R
T
GARDNER DRIVE
GARDNER
DRIVE
Sheet List Table
SHEET NUMBER SHEET TITLE
G001 COVER
G002 GENERAL NOTES
CX100 EXISTING CONDITIONS
CD100 DEMOLITION AND TREE REMOVAL PLAN
CS100 OVERALL SITE PLAN
CS101 ENLARGED SITE PLAN
CS102 ENLARGED SITE PLAN
CS103 ENLARGED SITE PLAN
CS104 ENLARGED SITE PLAN
CE101 SEDIMENT AND EROSION CONTROL - PHASE 1
CE102 SEDIMENT AND EROSION CONTROL - PHASE 2
CG100 OVERALL GRADING AND DRAINAGE PLAN
CG101 ENLARGED GRADING AND DRAINAGE PLAN
CG102 ENLARGED GRADING AND DRAINAGE PLAN
CG103 ENLARGED GRADING AND DRAINAGE PLAN
CU100 OVERALL UTILITIES PLAN
CU101 ENLARGED UTILITIES PLAN
CU102 ENLARGED UTILITIES PLAN
CU103 ENLARGED UTILITIES PLAN
CU104 ENLARGED UTILITIES PLAN
CU105 ENLARGED UTILITIES PLAN
CL100 OVERALL LANDSCAPE PLAN
CL101 ENLARGED LANDSCAPE PLAN
CL102 ENLARGED LANDSCAPE PLAN
CS501 SITE DETAILS
CE501 EROSION CONTROL DETAILS
CE502 EROSION CONTROL DETAILS
CG501 GRADING AND DRAINAGE DETAILS
CG502 GRADING AND DRAINAGE DETAILS
CU501 UTILITY DETAILS
CU502 UTILITY DETAILS
CU503 UTILITY DETAILS
CL501 LANDSCAPE DETAILS
CONSTRUCTION NOTES
1.CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH THE NEW HANOVER COUNTY
STANDARDS AND SPECIFICATIONS.
2.CONTRACTOR IS FULLY RESPONSIBLE FOR ACQUIRING THE LOCATION OF EXISTING UTILITIES
FROM THE APPROPRIATE PARTIES PRIOR TO CONSTRUCTION.
3.CONTRACTOR IS RESPONSIBLE FOR PLACING BARRICADES, USING FLAGMEN, ETC. AS
NECESSARY TO ENSURE SAFETY TO THE PUBLIC.
4.THESE DRAWINGS SHOW INFORMATION OBTAINED FROM THE AVAILABLE RECORDS REGARDING
PIPES, CONDUITS, TELEPHONE LINES, AND OTHER STRUCTURES AND CONDITIONS WHICH EXIST
ALL LINES OF WORK AND BELOW THE SURFACE OF THE GROUND. THE OWNER AND ENGINEER
DISCLAIM ANY RESPONSIBILITIES FOR THE ACCURACY OR COMPLETENESS OF SAID INFORMATION,
AND SUCH INFORMATION IS BEING SHOWN ONLY FOR THE CONVENIENCE OF THE CONTRACTOR
WHO MUST VERIFY THE INFORMATION TO HIS OWN SATISFACTION DURING THE BIDDING AND
CONSTRUCTION PHASES. IF THE CONTRACTOR RELIES ON SAID INFORMATION, HE DOES SO AT
HIS OWN RISK. THE GIVING OF THE INFORMATION ON THE CONTRACT DRAWINGS WILL NOT
RELIEVE THE CONTRACTOR OF HIS OBLIGATIONS TO SUPPORT AND PROTECT ALL PIPES,
CONDUITS, TELEPHONE LINES, AND OTHER STRUCTURES, WHETHER ABOVE OR BELOW GRADE.
5.THE CONTRACTOR SHALL VERIFY EXISTING INVERTS PRIOR TO CONSTRUCTION OF
UNDERGROUND UTILITIES. TEST PITTING OF EXISTING LINES PRIOR TO CONSTRUCTION, IF
NECESSARY, SHALL BE COORDINATED WITH THE OWNER.
6.ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL CONFORM TO THE DRAWINGS,
PROJECT SPECIFICATIONS, AND LOCAL BUILDING CODES.
7.ALL DISTURBED AREAS SHALL BE SMOOTHLY GRADED TO PROMOTE POSITIVE DRAINAGE AND
STABILIZED WITH TOPSOIL, SEED, AND MULCH. IF SETTLEMENT OCCURS, TOPSOIL, SEEDING, AND
MULCH SHALL BE REPEATED UNTIL SETTLEMENT SUBSIDES. (SEE EROSION AND SEDIMENT
CONTROL DETAILS AND SPECIFICATIONS.)
8.WATER MAINS WILL BE INSTALLED AT A DEPTH THAT WILL PROVIDE 36" COVER OVER THE PIPES
BELOW PROPOSED GRADE UNLESS SHOWN OTHERWISE ON THESE PLANS OR DIRECTED
OTHERWISE BY THE ENGINEER.
9.ALL WATER VALVES, BOXES, AND FIRE HYDRANT ASSEMBLES SHALL BE SET AND ADJUSTED TO
FINISHED GRADE.
10.THE OWNER IS RESPONSIBLE FOR THE ACQUISITION OF ALL EASEMENTS, BOTH TEMPORARY
AND PERMANENT.
11.THE CONTRACTOR SHALL VERIFY HORIZONTAL AND VERTICAL SURVEY CONTROL PRIOR TO
STAKING OUT CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF
THE ENGINEER PRIOR TO PROCEEDING WITH WORK.
12.ANY PROPERTY LINE MONUMENTATION DISTURBED DURING CONSTRUCTION SHALL BE REPLACED
SOLELY AT THE CONTRACTOR'S EXPENSE.
13.FIRE HYDRANTS SHALL BE PLACED A MINIMUM DISTANCE OF 6 FEET FROM BACK OF CURB AND
SHALL HAVE A CLEAR SPACE OF 3 FEET FROM ANY PERMANENT STRUCTURE PER CFPUA
STANDARDS.
14.ALL SELECT AND BORROW MATERIAL SHALL MEET CRITERIA OUTLINED IN THE GEOTECH REPORT.
15.THE ENGINEER AND THE CONTRACTOR SHALL INSPECT ALL EXISTING PIPES USED IN THE FINAL
DRAINAGE SYSTEM AND AGREE ON THE CONDITION OF THE PIPES PRIOR TO CONSTRUCTION. IF
DAMAGE OCCURS TO THESE PIPES DURING CONSTRUCTION, THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF THE PIPE(S).
16.EXISTING PAVING, CONCRETE, AND OTHER UNSUITABLE MATERIALS INCLUDING UNDERCUT
EXCAVATION SHALL NOT BE USED AS FILL MATERIAL AND SHALL BE DISPOSED OF OUTSIDE THE
PROJECT LIMITS AT THE CONTRACTOR'S EXPENSE. THE CONTRACTOR IS RESPONSIBLE FOR ALL
PERMITTING AND FEES FOR DISPOSAL.
17.ALL TREES, STUMPS, ROOT MAT, ETC. SHALL BE ENTIRELY REMOVED REGARDLESS OF DEPTH.
BURIAL OF ORGANIC MATERIAL WITHIN THE PROJECT LIMITS IS NOT PERMITTED. OPEN BURNING
OF DOWNED TREES AND STUMPS IS NOT PERMITTED. CHIPPED MATERIALS MUST BE REMOVED
PRIOR TO THE PLACEMENT OF EMBANKMENT OR TOPSOIL.
18.THE CONTRACTOR IS SOLELY RESPONSIBLE TO OBTAIN OFF-SITE SPOIL AREAS FOR DISPOSAL OF
EXCESS AND/OR UNSUITABLE MATERIALS AS NECESSARY. OFF-SITE SPOIL AREAS MUST BE
SUBMITTED TO THE ENGINEER AND APPLICABLE REGULATORY AGENCIES PRIOR TO UTILIZATION
BY THE CONTRACTOR. NO AREAS DESIGNATED AS WETLANDS WILL BE PERMITTED FOR USE AS A
DISPOSAL SITE. THE CONTRACTOR SHALL SUBMIT DOCUMENTATION TO THE ENGINEER THAT NO
WETLANDS WILL BE IMPACTED. THE ENGINEER WILL NOT CONSIDER ANY DELAYS OR MONETARY
CLAIMS OF ANY NATURE RESULTING FROM THE CONTRACTOR'S FAILURE OR DIFFICULTY IN
FINDING NECESSARY DISPOSAL SITES TO MEET THE TIME FRAMES AND CAPACITIES REQUIRED.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PLANS, PERMITS, EROSION AND SEDIMENT
CONTROL MEASURES, ETC. REQUIRED BY THE APPROPRIATE REGULATORY AGENCIES FOR
UTILIZING OFF-SITE SPOIL AREAS. THE CONTRACTOR SHALL CERTIFY TO THE ENGINEER THAT ALL
REQUIRED PERMITS HAVE BEEN OBTAINED PRIOR TO UTILIZING THE OFF-SITE SPOIL AREAS. ALL
COSTS FOR PROCURING AND UTILIZING THE OFF-SITE SPOIL AREAS ARE TO BE INCIDENTAL TO
THE BASE BID.
UTILITY COMPANY CONTACTS
DUKE/PROGRESS ENERGY:SID LIVINGSTON/MARK HATFIELD (910) 452-2777
DUKE ENERGY (TRANSMISSION): BILL WILDER (910) 772-4903
AT&T: JAMES BATSON (910) 452-5300
SPECTRUM: ROBERT JOHN (910) 216-4494
PIEDMONT NATURAL GAS: PAUL GONKA (910) 512-2841
DJ MEDEIROS (910) 431-3233
CAPE FEAR PUBLIC UTILITY AUTHORITY: (910) 332-6550
MATERIALS AND EASEMENT NOTES:
1.ALL DROP INLETS ARE NCDOT STD 840.14, 840.16
2.ALL STORM DRAINAGE PIPING TO BE CLASS IV RCP, UNLESS OTHERWISE NOTED
3.ALL STORM DRAINAGE PIPING CONVEYING DISCHARGE FROM THE PUBLIC
RIGHT-OF-WAY SHALL BE CONTAINED WITHIN A PUBLIC DRAINAGE EASEMENT WHOSE
WIDTH IS DETERMINED BY THE DEPTH OF BURY
4.ALL SANITARY SEWER LINES AND WATERLINES SHALL BE C-900 PVC, UNLESS
OTHERWISE NOTED AND MEET CAPE FEAR PUBLIC UTILITY SPECIFICATIONS
5.A PUBLIC UTILITY EASEMENT SHALL BE RESERVED WITHIN THE STREET
RIGHT-OF-WAY. A 10' NON-MUNICIPAL EASEMENT SHALL BE RESERVED ALONG BOTH
SIDES OF ALL STREETS
6.WATER AND SANITARY SEWER UTILITIES ARE PUBLIC - CAPE FEAR PUBLIC UTILITY
AUTHORITY
EXCAVATION, GRADING, AND BACKFILLING NOTES
1.ANY UNDERCUTTING IN GOOD SOIL SHALL BE REPLACED AND THE REPLACEMENT
MATERIAL SHALL BE COMPACTED TO NINETY-FIVE (95) PERCENT OF MAXIMUM DENSITY
OBTAINED AT OPTIMUM MOISTURE CONTENT, AS DETERMINED BY THE ASTM D 698
STANDARD PROCTOR TEST METHOD. IN THE EVENT THAT MATERIAL ENCOUNTERED AT
PIPE GRADE, SUBGRADE OF PARKING OR ROADWAYS AND SUBGRADE OF BUILDING
FOUNDATIONS IS FOUND TO BE SOFT, SPONGY, OR IN ANY OTHER WAY UNSUITABLE,
THE CONTRACTOR SHALL NOTIFY THE GEOTECHNICAL ENGINEER IMMEDIATELY. SUCH
UNSUITABLE MATERIAL SHALL BE REMOVED TO A DEPTH AS SPECIFIED BY THE
GEOTECHNICAL ENGINEER AND REPLACED WITH A MINIMUM OF SIX (6) INCHES OF
STONE, OR AS DIRECTED BY THE GEOTECHNICAL ENGINEER.
2.BEFORE BACKFILLING IS COMMENCED OVER PIPES AND OTHER INSTALLATIONS, EARTH
FILL SHALL BE SOLIDLY TAMPED AROUND AND ABOVE THE PIPE TO A DEPTH OF ONE (1)
FOOT ABOVE THE TOP OF THE PIPE. CARE SHALL BE TAKEN TO PREVENT ANY
DISTURBANCE TO THE PIPE OR DAMAGE TO NEWLY MADE JOINTS. THE FILLING OF THE
TRENCH SHALL BE CARRIED OUT SIMULTANEOUSLY ON BOTH SIDES OF THE PIPES IN
SUCH A MANNER THAT INJURIOUS SIDE PRESSURES DO NOT OCCUR.
3.THE MATERIAL FOR BACKFILLING SHALL BE FREE FROM ALL PERISHABLE AND
OBJECTIONABLE MATERIALS. BEFORE PLACING ANY BACKFILL, ALL RUBBISH, FORM,
BLOCKS, WIRES OR OTHER UNSUITABLE MATERIAL SHALL BE REMOVED FROM
EXCAVATION. THE BACK-FILLING OVER PIPES SHALL BE PLACED IN LAYERS NOT OVER
SIX (6) INCHES THICK AND COMPACTED TO A MINIMUM DENSITY OF NINETY-FIVE (95)
PERCENT OF THE MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR
COMPACTION TEST TO A DEPTH OF 12 INCHES BELOW FINISHED GRADE. THE LAST 12
INCHES OF BACKFILL SHALL BE PLACED IN LAYERS NOT OVER SIX (6) INCHES THICK AND
COMPACTED TO A MINIMUM DENSITY OF NINETY-EIGHT (98) PERCENT OF THE MAXIMUM
DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR COMPACTION TEST.
STORM DRAINAGE AND GRADING NOTES
1.IN ACCORDANCE WITH NC GENERAL STATUTES, NPDES REGULATIONS, AND NCDENR
REQUIREMENTS, STORMWATER DISCHARGE OUTFALLS SHALL BE INSPECTED BY THE
CONTRACTOR. INSPECTIONS SHALL BE PERFORMED BY THE CONTRACTOR AFTER EACH
STORM EVENT OF 1/2 INCH OR GREATER, WITH ONE WEEKLY INSPECTION MINIMUM.
NCDENR STANDARD INSPECTION REPORTS SHALL BE PREPARED AND SIGNED WITH
COPIES PROVIDED TO THE OWNER, ARCHITECT, AND ENGINEER, BY THE CONTRACTOR.
2.INLET PROTECTION SHALL BE INSTALLED AROUND OUTFALL. DEVICES SHALL BE
CONSTRUCTED TO FINAL PROPOSED CONDITION UPON STABILIZATION OF
CONTRIBUTING GROUND SURFACES AND REMOVAL OF SEDIMENT FROM STORM PIPES.
3.ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY
THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY
CONSTRUCTION MANAGER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH
CONSTRUCTION FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA
COMPENSATION SHALL BE PAID TO CONTRACTOR FOR ANY WORK DONE DUE TO
DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH
NOTIFICATION HAS NOT BEEN GIVEN.
4.UNLESS OTHERWISE NOTED, GRADES AND SPOT ELEVATIONS NOTED ON PLANS
INDICATE FINISHED GRADE OR PAVEMENT SURFACE. ALL DIMENSIONS ARE MEASURED
TO THE BACK OF CURB UNLESS OTHERWISE INDICATED.
5.COORDINATION WITH CITY SURVEYOR TO DETERMINE MONUMENTATION IS REQUIRED.
NOTE ON PLANS.
6.CONTRACTOR TO COORDINATE WITH CITY OF WILMINGTON CONSTRUCTION INSPECTOR
TO ENSURE EDGE OF CATCH BASIN GRATES ALIGN WITH TRAVEL LANE AS REQUIRED.
NOTE (G.S. 113A-57 (2))
THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER THAN THE ANGLE
THAT CAN BE RETAINED BY VEGETATIVE COVER OR OTHER ADEQUATE EROSION CONTROL
DEVICES OR STRUCTURES. IN ANY EVENT, SLOPES LEFT EXPOSED WILL, WITHIN 21
CALENDAR DAYS OF COMPLETION OF ANY GRADING, BE PLANTED OR OTHERWISE
PROVIDED WITH TEMPORARY OR PERMANENT GROUND COVER, DEVICES, OR STRUCTURES
SUFFICIENT TO RESTRAIN EROSION.
EROSION CONTROL NOTES
1.ANY GRADING BEYOND THE DENUDED LIMITS SHOWN ON THE PLAN IS A
VIOLATION OF THE COUNTY EROSION CONTROL ORDINANCE AND IS SUBJECT TO
A FINE.
2.GRADING MORE THAN ONE ACRE WITHOUT AN APPROVED EROSION CONTROL
PLAN IS A VIOLATION OF STATE LAW AND IS SUBJECT TO A FINE. ANY BUILDER
THAT ANTICIPATED THE DISTURBANCE OF MORE THAN ONE ACRE WILL BE
REQUIRED TO GET AN EROSION CONTROL PERMIT FROM NEW HANOVER COUNTY.
3.GROUND COVER MUST BE PROVIDED ON EXPOSED SLOPES WITHIN 21 CALENDAR
DAYS FOLLOWING COMPLETION OF ANY PHASE OF GRADING; AND, A PERMANENT
GROUND COVER FOR ALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR 90
CALENDAR DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF
CONSTRUCTION OR DEVELOPMENT.
4.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIRED
BY A REPRESENTATIVE OF NEW HANOVER COUNTY.
5.SLOPES SHALL BE GRADED NO STEEPER THAN 3:1.
6.ADDITIONAL DEVICES MAY BE REQUIRED AS AGREED UPON BY THE FIELD
INSPECTOR, ENGINEER, AND OWNER.
7.IF ACTIVE CONSTRUCTION CEASES IN ANY AREA FOR MORE THAN 15 WORKING
DAYS OR 90 CALENDAR DAYS (WHICHEVER IS SHORTER), ALL DISTURBED AREAS
MUST BE SEEDED, MULCHED, AND TACKED.
8.WITHIN 24 HOURS FOLLOWING ANY RAIN EVENT, THE CONTRACTOR SHALL
INSPECT AND REPAIR, AS NECESSARY, ALL DAMAGED EROSION CONTROL
MEASURES.
9.ALL ACTIVITY AND INSTALLATION OF EROSION CONTROL MATTING WILL BE
COMPLETE PRIOR TO ANY RAIN EVENT.
FIRE PROTECTION NOTES
1.LANDSCAPING OR PARKING CANNOT BLOCK OR IMPEDE FIRE HYDRANTS. A 3-FOOT CLEAR SPACE
SHALL BE MAINTAINED AROUND THE CIRCUMFERENCE OF THE HYDRANT AND FDC.
2.HYDRANTS MUST BE LOCATED WITHIN THE RIGHT OF WAY OR FIRST 5-FEET OF NON-MUNICIPAL
EASEMENT.
3.COMBUSTIBLE MATERIALS MAY NOT BE STORED OR ERECTED ONSITE WITHOUT COUNTY FIRE
INSPECTOR APPROVAL.
4.NEW HYDRANTS MUST BE AVAILABLE FOR USE PRIOR TO CONSTRUCTION OF ANY BUILDING(S).
5.CONTRACTOR SHALL MAINTAIN AN ALL WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES
DURING CONSTRUCTION.
6.FIRE HYDRANTS ARE TO BE INSTALLED PER CFPUA SPECIFICATIONS.
EROSION CONTROL MAINTENANCE PLAN:
1.ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSPECTED AND
REPAIRED, AS NECESSARY, EVERY SEVEN (7) DAYS AND WITHIN 24 HOURS OF
EVERY ONE-HALF (0.5) INCH OR GREATER RAINFALL.
2.ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED DURING ALL
PHASES OF CONSTRUCTION UNTIL THE COMPLETION OF ALL CONSTRUCTION
ACTIVITIES AND ALL DISTURBED AREAS HAVE BEEN STABILIZED. ADDITIONAL
CONTROL DEVICES MAY BE REQUIRED DURING CONSTRUCTION IN ORDER TO
CONTROL EROSION AND/OR OFFSITE SEDIMENTATION. ALL TEMPORARY CONTROL
DEVICES SHALL BE REMOVED ONCE CONSTRUCTION IS COMPLETE AND THE SITE
IS STABILIZED.
3.SEDIMENT SHALL BE REMOVED FROM BEHIND THE SILT FENCE WHEN IT BECOMES
ABOUT 0.5 FEET DEEP. THE SEDIMENT FENCE WILL BE REPAIRED OR REPLACED
AS NECESSARY TO MAINTAIN A BARRIER.
4.ALL AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED
ACCORDING TO SPECIFICATIONS IN THE VEGETATIVE PLAN TO MAINTAIN A
VIGOROUS, DENSE VEGETATIVE COVER.
5.STONE CONSTRUCTION ENTRANCE TO BE CLEANED WHEN SEDIMENT
ACCUMULATIONS ARE VISIBLE OR SEDIMENT IS TRACKED ON TO THE PAVEMENT.
STONE WILL BE PERIODICALLY TOP DRESSED WITH 2 INCHES OF #4 STONE TO
MAINTAIN 6 INCH DEPTH. THE CONTRACTOR SHALL DAILY REMOVE MUD/SOIL
FROM PAVEMENT, AS REQUIRED.
6.INSPECT CHECK DAMS AND CHANNELS AT LEAST WEEKLY AND AFTER EACH
SIGNIFICANT (1
2 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY.
CLEAN OUT SEDIMENT, STRAW, LIMBS, OR OTHER DEBRIS THAT COULD CLOG THE
CHANNEL WHEN NEEDED. ANTICIPATE SUBMERGENCE AND DEPOSITION ABOVE
THE CHECK DAM AND EROSION FROM HIGH FLOWS AROUND THE EDGES OF THE
DAM. CORRECT ALL DAMAGE IMMEDIATELY. IF SIGNIFICANT EROSION OCCURS
BETWEEN DAMS, ADDITIONAL MEASURES CAN BE TAKEN SUCH AS, INSTALLING A
PROTECTIVE RIPRAP LINER IN THAT PORTION OF THE CHANNEL.REMOVE
SEDIMENT ACCUMULATED BEHIND THE DAMS AS NEEDED TO PREVENT DAMAGE
TO CHANNEL VEGETATION, ALLOW THE CHANNEL TO DRAIN THROUGH THE STONE
CHECK DAM, AND PREVENT LARGE FLOWS FROM CARRYING SEDIMENT OVER THE
DAM. ADD STONES TO DAMS AS NEEDED TO MAINTAIN DESIGN HEIGHT AND
CROSS SECTION.
7.INSPECT TEMPORARY SEDIMENT BASINS AT LEAST WEEKLY AND AFTER EACH
SIGNIFICANT (1/2" OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY.
REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS
WHEN IT ACCUMULATES TO ONE-HALF THE DESIGN DEPTH. PLACE REMOVED
SEDIMENT IN AN AREA WITH SEDIMENT CONTROLS.
8.CHECK THE SEDIMENT BASIN EMBANKMENT, SPILLWAYS, AND OUTLET FOR
EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND
SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH
AND OTHER DEBRIS FROM THE RISER AND POOL AREA.
9.INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (0.5" OR
GREATER) RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER
OBJECTS TO PROVIDE ADEQUATE FLOW FOR SUBSEQUENT RAINS. TAKE CARE
NOT TO DAMAGE OR UNDERCUT THE WIRE MESH DURING SEDIMENT REMOVAL.
REPLACE STONE AS NEEDED. INLET PROTECTION SHOULD BE CLEANED OUT
WHEN IT IS HALF FULL.
10.INSPECT BAFFLES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE
ANY REQUIRED REPAIRS IMMEDIATELY. BE SURE TO MAINTAIN ACCESS TO THE
BAFFLES. SHOULD THE FABRIC OF A BAFFLE COLLAPSE, TEAR, DECOMPOSE, OR
BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS
WHEN IT REACHES HALF FULL TO PROVIDE ADEQUATE STORAGE VOLUME FOR
THE NEXT RAIN AND TO REDUCE PRESSURE ON THE BAFFLES. TAKE CARE TO
AVOID DAMAGING THE BAFFLES DURING CLEAN OUT. SEDIMENT DEPTH SHOULD
NEVER EXCEED HALF THE DESIGNED STORAGE DEPTH. AFTER THE
CONTRIBUTING DRAINAGE AREAS HAS BEEN PROPERLY STABILIZED, REMOVE ALL
BAFFLE MATERIALS AND UNSTABLE SEDIMENT DEPOSITS, BRING THE AREA TO
GRADE, AND STABILIZE IT.
11.INSPECT THE SKIMMER FOR CLOGGING. PULL THE SKIMMER TO THE SIDE OF THE
BASIN AND REMOVE ANY DEBRIS. ALSO CHECK THE ORIFICE INSIDE THE SKIMMER
AND THE ARM OR BARREL PIPE FOR CLOGGING; IF CLOGGED, REMOVE THE
DEBRIS.
12.INSPECT PERMANENT AND TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER
EVERY RAINFALL. IMMEDIATELY REMOVE SEDIMENT FROM THE FLOW AREA AND
REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TIMELY
REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED,
REMOVE THE RIDGE AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND
LEVEL AND APPROPRIATELY STABILIZE IT.
13.INSPECT WATTLES ONCE A WEEK AND AFTER EACH SIGNIFICANT (1/2 INCH OR
GREATER) RAIN FALL EVENT AND REPAIR IMMEDIATELY. CLEAN OUT SEDIMENT,
STRAW, LIMBS, OR OTHER DEBRIS THAT COULD CLOG THE CHANNEL WHEN
NEEDED. CORRECT ALL DAMAGE FROM SUBMERGENCE AND DEPOSITION ABOVE
THE CHECK DAM/WADDLE AND EROSION FROM HIGH FLOWS AROUND EDGES OF
DAM IMMEDIATELY.IF SIGNIFICANT EROSION OCCURS BETWEEN DAMS, INSTALL A
PROTECTIVE RIPRAP LINER IN THAT PORTION OF THE CHANNEL PER NCDENR
PRACTICE 6.31. REMOVE SEDIMENT ACCUMULATION BEHIND THE DAMS AS
NEEDED TO PREVENT DAMAGE TO THE CHANNEL VEGETATION/LINING, ALLOW THE
CHANNEL TO DRAIN THROUGH THE STONE CHECK DAM, AND PREVENT LARGE
FLOWS FROM CARRYING SEDIMENT OVER THE DAM/WADDLE. ADD STONES TO
CHECK DAMS AND REPAIR/REPLACE WATTLES AS NEEDED TO MAINTAIN DESIGN
HEIGHT AND CROSS SECTION.
14.INSPECT SILT FENCE ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY
REQUIRED REPAIRS IMMEDIATELY. SHOULD THE FABRIC OF A SEDIMENT FENCE
COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT
IMMEDIATELY. SEDIMENT SHALL BE REMOVED FROM BEHIND THE SILT FENCE
WHEN IT BECOMES ABOUT 0.5 FEET DEEP. THE SEDIMENT FENCE WILL BE
REPAIRED OR REPLACED AS NECESSARY TO MAINTAIN A BARRIER.
15.INSPECT RIPRAP OUTLET STRUCTURES WEEKLY AND AFTER SIGNIFICANT (1/2
INCH OR GREATER) RAINFALL EVENTS TO SEE IF ANY EROSION AROUND OR
BELOW THE RIPRAP HAS TAKEN PLACE, OF IF STONES HAVE BEEN DISLODGED.
IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE.
REPAIR OR REPLACE RIPRAP AS REQUIRED TO MAINTAIN EFFECTIVENESS.
CONTROL WEED AND BRUSH GROWTH AS NEEDED.
16.IF PROPOSED STORMWATER CONTROL MEASURES ARE USED AS SEDIMENT
BASINS DURING CONSTRUCTION, THEN PRIOR TO SCM CERTIFICATION THE
CONTRACTOR SHALL CLEAN THE SEDIMENT FROM THE SCM, INSTALL FOREBAY
BERM, INSTALL EMERGENCY OUTFALL MEASURES, AND GENERALLY BRING THE
SCM INTO COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND NCDEQ RULES
AND REGULATIONS.
17.INSPECT DIVERSION DIKES ONCE A WEEK AND AFTER EVERY RAINFALL.
IMMEDIATELY REMOVE SEDIMENT FROM THE FLOW AREA AND REPAIR THE DIKE.
CHECK OUTLETS, AND MAKE TIMELY REPAIRS AS NEEDED TO AVOID GULLY
FORMATION. WHEN THE AREA ABOVE THE TEMPORARY DIVERSION DIKE IS
PERMANENTLY STABILIZED, REMOVE THE DIKE, AND FILL AND STABILIZE THE
CHANNEL TO BLEND WITH THE NATURAL SURFACE.
DEMOLITION NOTES
1.THE CONTRACTOR SHALL VISIT THE SITE TO BECOME FAMILIARIZED WITH FIELD DEMOLITION
CONDITIONS.
2.THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER DISPOSAL OF ALL DEMOLISHED DEBRIS
ASSOCIATED WITH THE PROJECT IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS.
3.THE CONTRACTOR IS RESPONSIBLE FOR CONTROLLING DUST GENERATED BY THE WORK,
INCLUDING BUT NOT LIMITED TO DEMOLITION AND CONSTRUCTION ACTIVITIES, SITE
VEHICULAR TRAFFIC AND RELATED OPERATIONS.
4.THE CONTRACTOR IS RESPONSIBLE FOR HAVING ALL EXISTING UTILITIES LOCATED PRIOR TO
BEGINNING ANY DEMOLITION. CONTRACTOR SHALL CONTACT NC ONE CALL AT LEAST 72
HOURS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES
LOCATED.
5.EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND,
ARE BASED ON FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE
CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO BEGINNING RELATED
CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE OWNER'S
REPRESENTATIVE AND ENGINEER IMMEDIATELY.
6.THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF DISCONNECTING AND
ABANDONING ALL EXISTING UTILITIES WITH THE OWNER UNLESS OTHERWISE NOTED. ALL
EXISTING UTILITIES AND ASSOCIATED PIPING, ETC. NOT IN USE ON THE SITE SHALL BE
PROPERLY ABANDONED AND REMOVED AS REQUIRED. COORDINATE WITH THE OWNER.
7.THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ANY EXISTING UTILITIES THAT
REMAIN IN SERVICE DURING DEMOLITION.
8.THE CONTRACTOR IS RESPONSIBLE FOR STABILIZATION OF ALL DISTURBED AREAS AND
SLOPES ON AND OFF SITE IN ACCORDANCE WITH THE EROSION CONTROL MEASURES
SPECIFIED ON THE PLANS AND IN THE SPECIFICATIONS. THE CONTRACTOR SHALL
COORDINATE WITH THE OWNER TO DETERMINE WHO IS RESPONSIBLE FOR PROVIDING THE
PERMANENT STABILIZATION MEASURES AND THE TYPE OF PERMANENT MEASURES PRIOR TO
BEGINNING DEMOLITION AND CONSTRUCTION. THE PERMANENT STABILIZATION MEASURES
SHALL BE IN PLACE AND ACCEPTABLE TO THE OWNER'S REPRESENTATIVE AND ENGINEER
PRIOR TO PROJECT CLOSEOUT. COORDINATE INSPECTION WITH THE OWNER AND ENGINEER
PRIOR TO PROJECT CLOSEOUT.
9.THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND CONTACTING THE ENGINEER FOR
THE REQUIRED INSPECTIONS ON THE PROJECT.
10.WETLANDS DO EXIST ON SITE. WETLANDS WILL NOT BE DISTURBED DURING CONSTRUCTION OF
THIS PROJECT.
UTILITY NOTES
1.SCHEDULE A PRECONSTRUCTION MEETING WITH CAPE FEAR PUBLIC UTILITY
AUTHORITY 48 HOURS PRIOR TO CONSTRUCTION OF WATER AND SEWER LINES.
2.WATER AND SANITARY SEWER UTILITY MAINS ARE PRIVATE BEYOND THE PUBLIC
STREET RIGHT-OF-WAY.
3.THIS PROJECT SHALL COMPLY WITH THE CFPUA CROSS CONNECTION CONTROL
REQUIREMENTS. WATER METER(S) CANNOT BE RELEASED UNTIL ALL
REQUIREMENTS ARE MET AND NCDENR HAS ISSUED THE "FINAL APPROVAL".
4.ALL COMMERCIAL WATER SERVICES AND ANY IRRIGATION SYSTEMS SUPPLIED
BY CFPUA WATER SHALL HAVE A BACKFLOW PREVENTION DEVICE ACCEPTABLE
TO CFPUA AND APPROVED BY USCFCCCHR OR ASSE.
5.BACKFLOW PREVENTION AND METERS WILL BE PROVIDED FOR BOTH FIRE LINES
(RPDA) AND DOMESTIC SERVICE (RPZ). FIRE LINE BACKFLOW PREVENTER AND
DOMESTIC SERVICE BACKFLOW PREVENTER WILL BE LOCATED AS SHOWN ON
THE UTILITY PLANS. INSTALLER OF BACKFLOW PREVENTERS MUST CONTACT
CFPUA PRIOR TO INSTALLING UNITS TO GIVE CFPUA THE OPTION TO VERIFY
INSTALLATION PROCEDURES.
5.1.REDUCED PRESSURE PRINCIPLE ASSEMBLY FOR DOMESTIC WATER
SERVICE
5.2.REDUCE PRESSURE DETECTOR ASSEMBLY WILL BE UTILIZED FOR THE
BACKFLOW PREVENTER ON THE FIRE SERVICE.
6.IF THE CONTRACTOR DESIRES CFPUA WATER FOR CONSTRUCTION HE SHALL
APPLY IN ADVANCE FOR THIS SERVICE AND MUST PROVIDE A REDUCED
PRESSURE ZONE (RPZ) BACKFLOW PREVENTION DEVICE ON THE DEVELOPER'S
SIDE OF THE WATER METER BOX.
7.WATER: 1.5" AND 2" PVC SERVICES SHALL BE CONSTRUCTED USING ASTM D2241,
IPS, GASKETED PIPE, SDR 21. 4"-12" PVC MAINS AND SERVICES SHALL BE
CONSTRUCTED USING AWWA C-900 PVC, CL235 (DR-18). REQUIREMENTS OF
AWWA C900 ELASOMERIC PUSH-ON JOINTS.
8.SANITARY SEWER: FOR PIPE SIZES 4" AND 6" PIPE SHALL BE SCH 40
CONFORMING TO THE REQUIREMENTS OF ASTM D1785 WITH SOLVENT WELD
JOINTS CONFORMING TO ASTM D2672. FOR PIPE SIZES 8" THROUGH 12", PIPE
SHALL BE CLASS 150, DR18 CONFORMING TO THE REQUIREMENTS OF AWWA
C900 WITH ELASTOMERIC PUSH-ON JOINTS CONFORMING TO ASTM D3212 OR
ASTM D3139.
9.WATER AND SEWER SERVICES CANNOT BE ACTIVATED ON NEW MAINS UNTIL
ENGINEER'S CERTIFICATION AND AS-BUILTS ARE RECEIVED AND "FINAL
APPROVAL" ISSUED BY PUBLIC WATER SUPPLY SECTION OF NCDENR AND "FINAL
ENGINEERING CERTIFICATION" ISSUED BY DIVISION OF WATER QUALITY OF
NCDENR.
10.WATERLINE TRACER WIRE: SEE CFPUA DETAIL WD-17.
11.SITE UTILITY CONTRACTOR TO PROVIDE WATER AND SANITARY SEWER SERVICE
TO WITHIN 5 FEET OF THE BUILDING. CONTRACTOR SHALL COORDINATE SITE
PLAN CONNECTIONS WITH THE ARCHITECTURAL BUILDING PLANS.
12.MAXIMUM BENDING RADIUS FOR 8" C-900 PVC WATER MAIN BENDS IS 380'
(ONE-HALF MANUFACTURER'S RECOMMENDED ALLOWABLE LONGITUDINAL
BENDING).
13.UNDERGROUND UTILITIES: ALL NEW UTILITIES SHALL BE INSTALLED
UNDERGROUND, EXCEPT WHERE SUCH PLACEMENT IS PROHIBITED OR DEEMED
IMPRACTICAL BY THE UTILITY PROVIDER. UNDERGROUND TERMINAL FACILITIES
FOR STREET LIGHTING ALONG THE PUBLIC STREETS ABUTTING THE SUBJECT
SITE SHALL BE INSTALLED BY THE DEVELOPER.
14.MINIMUM OF 36" COVERAGE ABOVE ALL WATERMAINS.
15.MINIMUM OF 36" VERTICAL SEPARATION BETWEEN WATERLINES AND
STORMDRAIN CURB INLETS
16.A VARIANCE IS NOT ANTICIPATED FROM ANY NORTH CAROLINA DIVISION OF
WATER QUALITY (DWQ) REQUIREMENT.
17.PLANS ARE IN COMPLIANCE WITH CAPE FEAR PUBLIC UTILITY AUTHORITY
TECHNICAL STANDARDS AND SPECIFICATIONS.
RELATION OF WATER MAINS TO SANITARY SEWERS:
1.LATERAL SEPARATION OF SANITARY SEWERS AND WATER MAINS: WATER MAINS
SHALL BE LAID AT LEAST 10 FEET LATERALLY FROM EXISTING OR PROPOSED
SEWERS UNLESS LOCAL CONDITIONS OR BARRIERS PREVENT A 10 FOOT
LATERAL SEPARATION, IN WHICH CASE:
1.1.THE WATER MAIN IS LAID IN A SEPARATE TRENCH, WITH THE ELEVATION
OF THE BOTTOM OF THE WATER MAIN AT LEAST 18 INCHES ABOVE THE
TOP OF THE SEWER, OR
1.2.THE WATER MAIN IS LAID IN THE SAME TRENCH AS THE SEWER WITH THE
WATER MAIN LOCATED AT ONE SIDE ON A BENCH OF UNDISTURBED EARTH,
AND ABOVE THE TOP OF THE SEWER.
2.CROSSING A WATER MAIN OVER A SEWER MAIN: WHENEVER IT IS NECESSARY
FOR A WATER MAIN TO CROSS OVER A SEWER THE WATER MAIN SHALL BE LAID
AT SUCH AN ELEVATION THAT THE BOTTOM OF THE WATER MAIN IS AT LEAST 24
INCHES ABOVE THE TOP OF THE SEWER MAIN. UNLESS LOCAL CONDITIONS OR
BARRIERS PREVENT AN 18 INCH VERTICAL SEPARATION - IN WHICH CASE BOTH
THE WATER MAIN AND THE SEWER MAIN SHALL BE CONSTRUCTED OF FERROUS
MATERIALS AND WITH JOINTS THAT ARE EQUIVALENT TO WATER MAIN
STANDARDS FOR A DISTANCE OF 10 FEET ON EACH SIDE OF THE POINT OF
CROSSING.
3.CROSSING A WATER MAIN UNDER A SEWER MAIN: WHENEVER IT IS NECESSARY
FOR A WATER MAIN TO CROSS UNDER A SEWER MAIN BOTH THE WATER MAIN
AND THE SEWER MAIN SHALL BE CONSTRUCTED OF FERROUS MATERIALS AND
WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10
FEET ON EACH SIDE OF THE POINT OF CROSSING.
4.CROSSING A SEWER MAIN/WATER MAIN OVER OR UNDER A STORM DRAIN:
WHENEVER IT IS NECESSARY FOR A SEWER MAIN/WATER MAIN TO CROSS A
STORM DRAIN PIPE, THE SEWER MAIN/WATER MAIN SHALL BE LAID AT SUCH AN
ELEVATION THAT THE OUTSIDE OF THE SEWER MAIN/WATER MAIN NEAREST TO
THE OUTSIDE OF THE STORM DRAIN PIPE SHALL MAINTAIN A 24 INCH CLEAR
SEPARATION DISTANCE HORIZONTAL, OR THE SEWER MAIN/WATER MAIN SHALL
EITHER BE CONSTRUCTED OF DUCTILE IRON PIPE OR ENCASED IN EITHER
CONCRETE OR DUCTILE IRON PIPE FOR AT LEAST 5 FEET ON EITHER SIDE OF
THE CROSSING.
CONSTRUCTION SEQUENCE:
1.OBTAIN ALL NECESSARY PERMIT APPROVALS PRIOR TO ANY LAND DISTURBING
ACTIVITY.
2.HOLD A PRE-CONSTRUCTION MEETING WITH THE EROSION CONTROL INSPECTOR.
3.INSTALL GRAVEL CONSTRUCTION ENTRANCE, COMMENCE CLEARING TO INSTALL SILT
FENCE AND ROUGH GRADING OPERATIONS TO ESTABLISH TEMPORARY DIVERSION
DITCHES, AND SEDIMENT BASINS.
4.ROUGH GRADE ROADWAY AND SITE.
5.INSTALL STORM DRAINAGE SYSTEM WITH OUTLET PROTECTION DEVICES.
6.CONSTRUCT UNDERGROUND UTILITIES (WATER AND SANITARY SEWER).
7.PROVIDE TEMPORARY PROTECTION MEASURES AND DEVICES AS REQUIRED UNTIL
UNDERGROUND UTILITIES AND PAVEMENT SECTION IS COMPLETE AND FINAL GRADES
ARE STABILIZED WITH TEMPORARY VEGETATIVE COVER.
8.STABILIZE (FERTILIZE, SEED, AND MULCH) ALL DISTURBED AREAS AS SOON AS FINAL
GRADES ARE ESTABLISHED.
9.ONCE CONSTRUCTION IS COMPLETE AND ALL DISTURBED AREAS ARE STABILIZED,
REMOVE TEMPORARY EROSION CONTROL MEASURES, REMOVE SEDIMENT FROM
SEDIMENT BASIN AND RESTORE TO ORIGINAL DIMENSIONS.
TREE PROTECTION NOTES
1.PRIOR TO ANY CLEARING, GRADING, OR CONSTRUCTION ACTIVITY, TREE
PROTECTION FENCING WILL BE INSTALLED AROUND PROTECTED TREES OR
GROVES OF TREES. NO CONSTRUCTION WORKERS, TOOLS, MATERIALS OR
VEHICLES ARE PERMITTED WITHIN THE TREE PROTECTION FENCING.
2.NO LAND DISTURBANCE, INCLUDING TREE REMOVAL, IS TO OCCUR OUTSIDE THE
PROJECT BOUNDARY SHOWN ON THE PLANS, UNLESS OTHERWISE NOTED. TREE
PROTECTION FENCING IS SHOWN OUTSIDE OF PROJECT BOUNDARY FOR
PROTECTION OF EXISTING TREES IN CLOSE PROXIMITY TO PROPOSED
CONSTRUCTION.
3.PROTECTIVE FENCING IS TO BE PROPERLY MAINTAINED THROUGHOUT THE
DURATION OF THE PROJECT AND CONTRACTOR SHALL RECEIVE ADEQUATE
INSTRUCTIONS ON TREE PROTECTION METHODS.
4.LAND CLEARING AND CONSTRUCTION CONTRACTORS SHALL RECEIVE
ADEQUATE INSTRUCTION ON TREE PROTECTION REQUIREMENTS AND METHODS.
5.NO EQUIPMENT IS ALLOWED ON THE SITE UNTIL ALL TREE PROTECTION FENCING
AND SILT FENCING HAS BEEN INSTALLED AND APPROVED BY THE LANDSCAPE
ARCHITECT.
6.ANY TREES AND/OR AREAS DESIGNATED TO BE PROTECTED MUST BE
PROPERLY BARRICADED WITH FENCING AND PROTECTED THROUGHOUT
CONSTRUCTION TO INSURE THAT NO CLEARING AND GRADING OR STAGING OF
MATERIALS WILL OCCUR IN THOSE AREAS.
7.REGULATED AND SIGNIFICANT TREES IN THE STREET YARD AND ANY TREES IN
ANY REQUIRED BUFFERS SHALL TO BE RETAINED [62.1-3(1) (A) & (B)].
CAPE FEAR PUBLIC UTILITY AUTHORITY CONSTRUCTION
PROCEDURE:
1.THE DESIGN ENGINEERING SHALL SUBMIT 3 SETS OF FINAL DESIGN PLANS AND
APPROVED SPECIFICATIONS PRIOR TO SCHEDULING THE PRE-CONSTRUCTION
MEETING.
2.SUBMITTALS FOR MATERIALS SHOULD BE MADE IN ACCORDANCE WITH CFPUA
SPECIFICATION SECTION 01340. MATERIAL SHOP DRAWING SUBMITTALS ARE
REQUIRED FOR ALL PHYSICAL ASSETS TO ENSURE THEY COMPLY WITH CFPUA
TECHNICAL SPECIFICATIONS AND DETAILS. THESE SUBMITTALS ARE
PROJECT-SPECIFIC, AND MUST INCLUDE OR HIGHLIGHT ONLY THE SPECIFIC MATERIALS
TO BE USED IN THE PROJECT. THE SUBMITTAL APPROVAL PROCESS IS GENERALLY AS
FOLLOWS:
MATERIAL VENDOR FURNISHES SUBMITTALS TO THE CONTRACTOR BASED ON THE
PROJECT REQUIREMENTS.
CONTRACTOR REVIEWS THE SUBMITTALS FOR COMPLIANCE WITH THE APPROVED
CONSTRUCTION DRAWINGS, CFPUA TECHNICAL SPECIFICATIONS AND DETAILS, AND
FORWARDS TO THE DEVELOPER’S ENGINEER-OF-RECORD WHEN COMPLETE.
THE DEVELOPER'S ENGINEER-OF-RECORD VERIFIES COMPLIANCE, STAMPS AND SIGNS
THE SUBMITTAL, AND FORWARDS THE PACKAGE TO THE CFPUA CONSTRUCTION
MANAGER. IF IT IS DETERMINED THAT THE MATERIAL SHOP DRAWING SUBMITTAL IS
NOT IN COMPLIANCE, THE ENGINEER SHALL RETURN IT TO THE CONTRACTOR FOR
CORRECTION AND RESUBMISSION AS NOTED ABOVE.
CFPUA’S CONSTRUCTION MANAGER REVIEWS THE SUBMITTAL FROM THE DEVELOPER’S
ENGINEER-OF-RECORD, VERIFIES COMPLIANCE, AND NOTIFIES THE ENGINEER THAT
THE MATERIALS ARE APPROVED FOR CONSTRUCTION. IF IT IS DETERMINED THAT THE
MATERIAL SHOP DRAWING SUBMITTAL IS NOT IN COMPLIANCE, THE SUBMITTAL WILL BE
RETURNED TO THE ENGINEER FOR CORRECTION AND RESUBMISSION AS NOTED
ABOVE.
3.ANY REQUEST FOR DEVIATIONS FROM THE STAMPED DRAWINGS AND MATERIAL
SUBMITTALS MUST BE SUBMITTED TO THE CFPUA CONSTRUCTION MANAGER. THE
DEVIATION WILL BE REVIEWED BY CFPUA STAFF. THE ENGINEER, CONTRACTOR AND
CFPUA INSPECTOR WILL BE NOTIFIED IF IT IS APPROVED, NEEDS TO BE REVISED AND
RESUBMITTED OR REJECTED. ANY CHANGES TO THE STAMPED CONSTRUCTION
DOCUMENTS MADE IN THE FIELD BY THE CONTRACTOR MUST BE APPROVED BY THE
ENGINEER OF RECORD AND CFPUA CONSTRUCTION MANAGER. THE CFPUA INSPECTOR
CANNOT APPROVE MAJOR CHANGES FROM THE STAMPED CONSTRUCTION
DOCUMENTS.
4.THE CFPUA INSPECTOR SHALL BE NOTIFIED WHEN ANY MATERIAL IS DELIVERED TO
THE JOB SITE. THE CFPUA INSPECTOR WILL VERIFY THAT ALL MATERIALS MEET CFPUA
SPECIFICATIONS, DETAILS, AND/OR APPROVED SUBMITTAL. THE CFPUA INSPECTOR
WILL NOTIFY THE CONTRACTOR AND THE CFPUA CONSTRUCTION MANAGER OF ANY
UNAPPROVED MATERIAL, AND THAT THE UNAPPROVED MATERIAL MUST BE REMOVED
FROM THE PROJECT SITE.
5.CONTRACTOR SHALL GIVE TWO (2) BUSINESS DAYS NOTIFICATION FOR SCHEDULING
TO THE ASSIGNED CFPUA INSPECTOR FOR EACH OF THE FOLLOWING:
-OPERATING A CFPUA VALVE (INCLUDES TAPPING VALVES)
-WHEN BEGINNING CONSTRUCTION AND IF THE CONTRACTOR PULLS OFF THE SITE
-LAYING OUT OF ANY CONNECTION IN EXISTING MANHOLE
-CUTTING IN ANY NEW MANHOLES ON EXISTING LINES
-CORING ANY MANHOLES
-CONNECTING TO AN EXISTING SEWER FORCE MAINS
-CONNECTING ONTO EXISTING WATER LINES
-ANY BORES AND THREADING CARRIER PIPES
-ALL CAMERA WORK, TESTING, CHLORINATION AND WATER SAMPLING
-ALL TESTING
CAPE FEAR PUBLIC UTILITY AUTHORITY TESTING
PROCEDURE:
1.ALL STRUCTURES, PRESSURE PIPING AND GRAVITY SEWER PIPING SHALL BE TESTED
BY THE CONTRACTOR AS SPECIFIED IN THE CFPUA SPECIFICATIONS IN ACCORDANCE
WITH APPLICABLE REGULATIONS AND AS DIRECTED BY THE CFPUA INSPECTOR. ALL
TESTING MUST BE CONDUCTED IN THE PRESENCE OF THE CFPUA INSPECTOR. THE
CONTRACTOR IS TO GIVE TWO (2) BUSINESS DAYS NOTIFICATION FOR SCHEDULING, TO
THE ASSIGNED CFPUA INSPECTOR FOR ALL TESTING.
2.ALL PRESSURE PIPE LINES MUST BE SUBJECTED TO HYDROSTATIC TESTING IN
ACCORDANCE WITH THE APPROPRIATE CFPUA SPECIFICATION. THESE PIPE LINES
SHALL BE TESTED TO 150 PSI FOR A PERIOD OF TWO (2) HOURS. IF THE PRESSURE
DROPS MORE THAN THREE (3) PSI, THE TEST FAILS. REFER TO THE APPROPRIATE
CFPUA SPECIFICATION FOR MORE INFORMATION ON THE PROCEDURE.
3.ALL WATER MAINS AND SERVICES MUST BE FLUSHED, CHLORINATED AND SAMPLED IN
ACCORDANCE WITH THE CFPUA SPECIFICATION 02660 AND AS DIRECTED BY THE
CFPUA INSPECTOR.
4.SEWER LINE SEGMENT TESTING: EACH SEWER LINE SEGMENT (THE SEWER MAIN
BETWEEN MANHOLES) SHALL BE TESTED:
THIRTY (30) DAYS AFTER INSTALLATION AND PRIOR TO FINAL ACCEPTANCE OF THE
PROJECT, ALL SEWER LINE SEGMENTS AND ALL SERVICES SHALL BE CAMERA
INSPECTED AND VIDEO RECORDED. THE CFPUA INSPECTOR WILL REVIEW THE VIDEO
RECORDING FOR ACCEPTANCE.
AS AN ALTERNATIVE TO WAITING THIRTY (30) DAYS TO PERMIT STABILIZATION OF THE
SOIL-PIPE SYSTEM, THE CFPUA MAY ACCEPT CERTIFICATION FROM A SOIL TESTING FIR
VERIFYING THAT THE BACKFILL OF THE TRENCH HAS BEEN COMPACTED TO AT LEAST
95% MAXIMUM DENSITY.
AFTER TWO (2) PAPER COPIES OF THE AS-BUILTS HAVE BEEN SUBMITTED TO THE
CFPUA INSPECTOR.
AFTER GRAVEL HAS BEEN INSTALLED ON ALL ROADWAYS.
5.VIDEO INSPECTION TESTING: THE CONTRACTOR SHALL PROVIDE A DVD(S) OF EACH
SEWER LINE SEGMENT AND SERVICE LINE TO ENSURE THAT THE LINES MEET MINIMUM
STANDARDS. THE DVD(S) WILL BE REVIEWED IN THE ORDER THEY ARE RECEIVED. THE
TYPICAL REVIEW TIME IS GENERALLY TEN (10) TO FIFTEEN (15) BUSINESS DAYS BUT
WILL DEPEND ON THE COMPLEXITY OF THE PROJECT, SIZE, QUALITY OF THE DVD(S),
ETC.
THE MAIN LINE CAMERA INSPECTION MUST HAVE PROJECT NAME, FOOTAGES,
MANHOLE NUMBERS, AND DATES OF INSPECTION.
THE SERVICE LINE CAMERA INSPECTION MUST INCLUDE PROJECT NAME, FOOTAGES,
ADDRESS AND/OR LOT NUMBER, AND DATE OF INSPECTION.
THE CAMERA INSPECTION MUST SHOW THE FULL DIAMETER OF THE PIPE.
THE CAMERA INSPECTION MUST BE PERFORMED UPON COMPLETION OF CLEANING
AND POTABLE WATER INTRODUCED INTO THE SYSTEM TO BE TESTED. ALL DEFECTS IN
THE PIPELINE AND APPURTENANCES SHALL BE REMEDIED BY THE CONTRACTOR AT NO
ADDITIONAL EXPENSE TO THE CFPUA AND WILL BE RE-INSPECTED AS OUTLINED
ABOVE.
6.TWO (2) SETS OF AS-BUILT RECORD DRAWINGS SHALL BE PROVIDED IN ACCORDANCE
WITH CFPUA SPECIFICATION SECTION 01720 FOR REVIEW.
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
G002
GENERAL NOTES
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
CX100
EXISTING
CONDITIONS
30.0
'
UTIL
I
T
Y
E
A
S
E
M
E
N
T
WETLAND
0.53 ACRES
WETLAND
LINE
TRACT 2
NON-AERONAUTICAL TRACT
29.42 ACRES TOTAL
1.18 ACRES GARDNER DRIVE R\W TO BE CLOSED
TRACT 1
AERONAUTICAL TRACT
10.00 ACRES
NEW HANOVER COUNTY
AIRPORT AUTHORITY
NEW HANOVER COUNTY
AIRPORT AUTHORITY
NEW HANOVER COUNTY
AIRPORT AUTHORITY
NEW HANOVER COUNTY
AIRPORT AUTHORITY
WETLAND
WETLAND
50.0
'
BU
I
L
D
I
N
G
S
E
T
B
A
C
K
HVAC(
S
)
BU
I
L
D
I
N
G
SSMHRIM:32.
3
3
'
SSMH
RIM:32.
3
8
'
INV. :
2
4
.
7
0
'
12" D
I
P
(
B
U
R
R
I
E
D
)
INV. :
2
4
.
7
4
'
12" D
I
P
(
B
U
R
R
I
E
D
)
INV. :
2
4
.
5
5
'
1
8
"
F
E
S
R
C
P
GATE
GATE
GATE
CHAI
N
-
L
I
N
K
A
I
R
P
O
R
T
PERI
M
E
T
E
R
F
E
N
C
E
CHAI
N
-
L
I
N
K
A
I
R
P
O
R
T
PERI
M
E
T
E
R
F
E
N
C
E
INV.:
2
5
.
8
2
'
1
2
"
C
M
P
INV.:
2
5
.
9
7
'
1
2
"
C
M
P
INV.:
2
5
.
0
5
'
1
2
"
C
M
P
INV.:
2
5
.
0
6
'
1
2
"
C
M
P
BUIL
D
I
N
G
F
O
U
N
D
A
T
I
O
N
WET
A
R
E
A
WETLAND
0.53 ACRES
WETLAND
LINE
TRACT 2
NON-AERONAUTICAL TRACT
29.42 ACRES TOTAL
1.18 ACRES GARDNER DRIVE R\W TO BE CLOSED
TRACT 1
AERONAUTICAL TRACT
10.00 ACRES
NEW HANOVER COUNTY
AIRPORT AUTHORITY
NEW HANOVER COUNTY
AIRPORT AUTHORITY
NEW HANOVER COUNTY
AIRPORT AUTHORITY
NEW HANOVER COUNTY
AIRPORT AUTHORITY
WETLAND
WETLAND
DROP INLET
RIM:26.30'
INV.:19.42' 48" RCP
TYPICAL TREE
TO BE REMOVED
GARDNER ROAD REMOVAL - ROW TO BE REMOVED
GRAVEL DRIVE REMOVAL
± 1,720 LF OF FORCE MAIN
TO BE ABANDONED IN PLACE
± 2,030 LF OF FENCE
REMOVAL;
FENCE TO BE REROUTED
TYPICAL TREE
TO REMAIN
GRAVEL DRIVE REMOVAL
18LF OF STORM PIPE TO BE REMOVED
18LF OF STORM PIPE TO BE REMOVED
20LF OF STORM PIPE TO BE REMOVED
OVERHEAD
ELECTRIC TO BE
REMOVED
REMOVE
EXISTING 24" RCP
REMOVE
EXISTING 24" RCP
REMOVE
EXISTING DROP INLET
REMOVE
EXISTING DROP INLET
REMOVE
EXISTING 30" RCP
NEW FORCE MAIN WILL BE REROUTED
TO CONNECT TO EXISTING FORCE MAIN
ON GARDNER DRIVE
LEGEND AND NOTES1SCALE: 1"= 100'DEMO PLAN2
0
SCALE: 1"=20' (Horiz.)
40'20'20'
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
TREE REMOVAL PLAN
1.TREE REMOVAL WILL INVOLVE CLEARING OF THE VEGETATION UNDER THE
ESSENTIAL SITE IMPROVEMENTS.
DEMOLITION NOTES
1.NO EARTH DISTURBING ACTIVITIES INCLUDING TREE REMOVAL SHALL
COMMENCE UNTIL ALL PERIMETER EROSION CONTROL MEASURES ARE IN
PLACE IN ACCORDANCE WITH THE EROSION CONTROL SEQUENCE SHOWN
IN THESE PLANS.
2. NO EARTH-DISTURBING ACTIVITY OR OTHER WORK SHALL TAKE PLACE
WITHIN WETLANDS AREAS NOTED ON SURVEY. CONTRACTOR SHALL FIELD
VERIFY WETLAND LIMITS FLAGGING IN PLACE AND SHALL NOT ENTER
WETLAND AREAS. IF WETLAND FLAGGING IS MISSING OR OTHERWISE
DAMAGES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTE WETLAND
LIMITS AND PREVENT DISTURBANCE OR OTHER ACTIVITY WITHIN
WETLANDS.
3. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR THE PROTECTION
OF ALL PROPERTY CORNER MONUMENTS, AND SHALL HAVE, AT HIS
EXPENSE, ALL CORNER MONUMENTS REPLACED WHICH ARE DISTURBED
BY CONSTRUCTION ACTIVITIES.
4. CONTRACTOR IS RESPONSIBLE FOR REPAIRS OF DAMAGE TO ANY
EXISTING IMPROVEMENTS, AT HIS EXPENSE, DURING CONSTRUCTION,
SUCH AS, BUT NOT LIMITED TO, DRAINAGE, UTILITIES, PAVEMENT,
STRIPING, CURB, ETC. REPAIRS SHALL BE EQUAL TO OR BETTER THAN
EXISTING CONDITIONS.
5. CONTRACTOR SHALL COMPLY TO THE FULLEST EXTEND WITH ALL
REGULATIONS GOVERNING THE DEMOLITION, REMOVAL, TRANSPORTATION
AND DISPOSAL OF ALL DEMOLITION DEBRIS.
6. CONTRACTOR SHALL COMPLY TO THE FULLEST EXTENT WITH THE LATEST
OSHA STANDARDS FOR EXCAVATION AND TRENCHING PROCEDURES.
CONTRACTOR SHALL USE SUPPORT SYSTEMS, SLOPING, BENCHING, ETC.
AS NECESSARY FOR THESE OPERATIONS, AND SHALL COMPLY WITH ALL
OSHA PERFORMANCE CRITERIA.
7. CONTRACTOR SHALL TAKE SPECIAL CARE TO PROTECT ALL UTILITIES AND
APPURTENANCES TO REMAIN.
8.FENCE SHALL NOT BE REMOVED UNTIL NEW TEMPORARY FENCE IS
INSTALLED AND APPROVED BY TSA/ILM.
HARDSCAPE TO BE REMOVED
UTILITY TO BE REMOVED
DEMOLITION LEGEND
FENCE TO BE REMOVED
TREE TO BE REMOVED
TREE LEGEND
MISC HARDWOOD
MAPLE
BAY
PINE
LIVE OAK
OAK
MAGNOLIA
GUM
CRAPE
CHERRY
CEDAR
CD100
DEMOLITION AND
TREE REMOVAL PLAN
B
L
U
E
C
L
A
Y
R
O
A
D
TAXIWAY
C
E
N
T
E
R
L
I
N
E
+
-
TAXIWAY
O
B
J
E
C
T
F
R
E
E
Z
O
N
E
C
S
X
T
R
A
N
S
P
O
R
T
A
T
I
O
N
R
A
I
L
R
O
A
D
C
E
N
T
E
R
L
I
N
E
30.0
'
UTI
L
I
T
Y
E
A
S
E
M
E
N
T
50.0
'
BU
I
L
D
I
N
G
S
E
T
B
A
C
K
GATE
GA
R
D
N
E
R
D
R
I
V
E
VANVAN
VA
N
VA
N
EXISTING RUNWAY
WETLAND
TRUCK RECEIVING
AND DELIVERY
WETLAND
PROPOSED COLD
STORAGE BUILDING
(509,000 SF)
FFE = 28.5'
TRAILER STORAGE
15' X 55'
EXISTING TSA
GRAVEL ACCESS ROAD
EXISTING FAA
PERIMETER FENCE
EMPLOYEE LOT
111 SPACES
2 ADA SPACES
TOTAL SPACES: 113
26' "PRIVATE" DRIVE
30' DRIVE
SANITARY SEWER
GRINDER PUMP STATION
PROPOSED
FAA FENCE REALIGNMENT
FIRE ACCESS ROADFIRE ACCESS ROAD
EMPLOYEE/VISITOR LOT
126 SPACES
5 ADA SPACES
TOTAL SPACES: 131
67'
310
'
88'
7
8
'
19'
21'
15'
30' UTILITY EASEMENT
PROPOSED TSA
SECURITY ROAD REALIGNMENT
26
'
26
'
PROPOSED
FAA FENCE REALIGNMENT
BEGINNING OF
"PRIVATE" DRIVE
PROPOSED TSA
SECURITY ROAD REALIGNMENT
PROPOSED
FAA FENCE REALIGNMENT
LEGEND AND NOTES1SCALE: 1"= 100'OVERALL SITE PLAN2
0
SCALE: 1"=100' (Horiz.)
200'100'100'
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
SITE INFORMATION
PARCEL AREA:39.42 ACRES
SITE ADDRESS:XX GARDNER DRIVE
TOTAL NUMBER OF BUILDINGS:(1) COMMERCIAL
FLOOD PLAIN:
ZONE X - PANEL 3129
AREA DETERMINED TO BE OUTSIDE
OF THE 0.2% ANNUAL CHANCE
FLOODPLAIN
PHASING:
BUILDING AREA:509,783 SF GFA
BUILDING HEIGHT:35' MINIMUM, 47' MAXIMUM
NUMBER OF STORIES:2
IMPERVIOUS AREA:850,505 SF
BUILT UPON AREA:
PARCEL IDENTIFICATION NUMBER:
R04200-001-025-00T
R03300-005-006-000
R03300-005-007-000
R03300-005-007-001
R03300-005-008-000
ADJACENT PARCELS:
ZONING:AC
SETBACKS:REQUIRED PROVIDED
FRONT:50'66'
REAR (RUNWAY RESTRICTION LINE):750'752'
SIDE, STREET:50'N/A
SIDE INTERIOR:0'77'
PARKING:244
TRUCK PARKING/ TRAILER STORAGE:14
CS100
OVERALL SITE PLAN
VA
N
5
20
20
20
20
581 SF581 SF
581 SF581 SF
26'
7
8
'
2
6
'
9' (TYP)
18
'
(
T
Y
P
)
9' (TYP)
18' (TYP)
30' PROPOSED
UTILITY EASEMENT
581 SF581 SF
581 SF581 SF
126'
91'
14
14
22
'
135'
R4.50' (TYP)
31'
22
'
PROPOSED
509,000 SF BUILDING
FFE=28.50'
EMPLOYEE/VISITOR LOT
126 SPACES
5 ADA SPACES
TOTAL SPACES: 131
26' DRIVE
ADA PARKING SPACE (TYP)
24" CONCRETE RIBBON CURB
AROUND BUILDING PERIMETER
(WHERE SHOWN, SEE DETAIL)
24" CONCRETE RIBBON CURB
AROUND BUILDING PERIMETER
(WHERE SHOWN, SEE DETAIL)
RELOCATED
ACCESS GATE
SECURED ACCESS GATE WITH KNOX
ENTRY BOX AND SIREN ACTIVATION
9
9
GENERATORS
(BY OTHERS)
25
4
'
31'
26'
TRANSFORMER
(BY OTHERS)
GA
R
D
N
E
R
D
R
I
V
E
FLARED ADA
ACCESSIBLE RAMP (TYP)
ADA PARKING SIGN (TYP)
BEGINNING OF
"PRIVATE" DRIVE
2' VERTICAL
CURB AND GUTTER
(TYP.)
PROPOSED TSA
SECURITY ROAD REALIGNMENT
PROPOSED
FAA FENCE REALIGNMENT
26' FIRE ACCESS ROAD
26
'
R25.00'
R25.00'
2' VERTICAL
CURB AND GUTTER
(TYP.)
17' TYP.
17' TYP.
TRASH DUMPSTER WITH CMU
ENCLOSURE AND DUAL SWING
GATES. SEE ARCHITECTURAL
DRAWINGS FOR DETAILS.
35
'
T
Y
P
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
SCALE: 1"= 30'ENLARGED SITE PLAN3 LEGEND AND NOTES1
SCALE: 1"= 500'KEY MAP2
0
SCALE: 1"=30' (Horiz.)
60'30'30'
CS101
ENLARGED SITE
PLAN
SURFACE MATERIAL LEGEND:
ASPHALT PAVEMENT
CONCRETE
8" BABC STONE
NOTES:
- ALL CURB TO BE SPILL CURB UNLESS NOTED
DIFFERENTLY ON PLAN
VANVAN
VA
N
2020
14
8
9
14
10 10
14
8
TRUCK RECEIVING AND
DELIVERY AREA
PROPOSED
509,000 SF BUILDING
FFE=28.50'
581 SF581 SF 581 SF
581 SF
22
'
22'
22
'
22'
22'
26
'
30'
126'126'
72
'
22'
FC-FC
R20.00'R20.00'
R4.50' (TYP)
R4.50' (TYP)
9' (TYP)9' (TYP)
18' (TYP)
55'
15
'
30' PROPOSED
UTILITY EASEMENT
30
'
30'
30'
TRUCK LOADING DOCK
APRON
EMPLOYEE PARKING
111 SPACES
2 ADA SPACES
TOTAL SPACES: 113
TRAILER STORAGE
15' X 55'
26' FIRE
ACCESS ROAD
SANITARY SEWER
GRINDER PUMP STATION
RIBBON CURB
RIBBON CURB
ADA
PARKING SPACE
24" CONCRETE RIBBON CURB
AROUND BUILDING PERIMETER
(WHERE SHOWN, SEE DETAIL)
CONCRETE WHEEL STOP
26' FIRE ACCESS ROAD
SEE "INSET A" ON
NEXT SHEET FOR
CONTINUATION OF
FIRE ACCESS ROAD
10' CONCRETE DOLLY STRIP
MECHANICAL YARD - INCLUDING GENERATOR,
HEAT PUMP AND CONDENSING UNITS (BY OTHERS)
B
L
U
E
C
L
A
Y
R
O
A
D
C
S
X
T
R
A
N
S
P
O
R
T
A
T
I
O
N
R
A
I
L
R
O
A
D
C
E
N
T
E
R
L
I
N
E
21
8
'
R20.00'
TRASH DUMPSTER WITH CMU
ENCLOSURE AND DUAL SWING
GATES. SEE ARCHITECTURAL
DRAWINGS FOR DETAILS.
TRANSFORMER
(BY OTHERS)
ADA ACCESSIBLE RAMP (TYP)ADA PARKING SIGN (TYP)
ADA PARKING SIGN
2' VERTICAL
CURB AND GUTTER
(TYP.)
R15.00'
R20.00'
PROPOSED
FAA FENCE REALIGNMENT
17' TYP.
17' TYP.22
'
SECURED ACCESS GATE WITH KNOX
ENTRY BOX AND SIREN ACTIVATION
SECURED ACCESS GATE WITH KNOX
ENTRY BOX AND SIREN ACTIVATION
35
'
T
Y
P
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
SCALE: 1"= 30'ENLARGED SITE PLAN3 LEGEND AND NOTES1
SCALE: 1"= 500'KEY MAP2
0
SCALE: 1"=30' (Horiz.)
60'30'30'
CS102
ENLARGED SITE
PLAN
SURFACE MATERIAL LEGEND:
ASPHALT PAVEMENT
CONCRETE
8" BABC STONE
NOTES:
- ALL CURB TO BE SPILL CURB UNLESS NOTED
DIFFERENTLY ON PLAN
PROPOSED CONCRETE
JET RAMP
PROPOSED TARMAC TO
CONNECT RAMP TO TAXIWAY
WETLANDS TO REMAIN
EXISTING FAA
PERIMETER FENCE
PROPOSED TSA
SECURITY ROAD REALIGNMENT
2' VERTICAL
CURB AND GUTTER
(TYP.)
PROPOSED
FAA FENCE REALIGNMENT
PROPOSED
FAA FENCE REALIGNMENT
EXISTING TSA
GRAVEL ACCESS ROAD
26' FIRE
ACCESS ROAD
B
L
U
E
C
L
A
Y
R
O
A
D
EXISTING GATE
TO REMAIN
PROPOSED GATE
C
S
X
T
R
A
N
S
P
O
R
T
A
T
I
O
N
R
A
I
L
R
O
A
D
C
E
N
T
E
R
L
I
N
E
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
SCALE: 1"= 30'ENLARGED SITE PLAN3 LEGEND AND NOTES1
SCALE: 1"= 500'KEY MAP2
0
SCALE: 1"=30' (Horiz.)
60'30'30'
CS103
ENLARGED SITE
PLAN
SURFACE MATERIAL LEGEND:
ASPHALT PAVEMENT
CONCRETE
8" BABC STONE
NOTES:
- ALL CURB TO BE SPILL CURB UNLESS NOTED
DIFFERENTLY ON PLAN
INSET A
FIRE ACCESS ROAD
0
SCALE: 1"=30' (Horiz.)
60'30'30'
20 581 SF581 SF
14
135'
31'
22
'
EMPLOYEE/VISITOR LOT
126 SPACES
5 ADA SPACES
TOTAL SPACES: 131
PROPOSED
FAA FENCE REALIGNMENT
24" CONCRETE RIBBON CURB
AROUND BUILDING PERIMETER
(WHERE SHOWN, SEE DETAIL)
PROPOSED TSA
SECURITY ROAD REALIGNMENT
9
FLARED ADA
ACCESSIBLE RAMP (TYP)
26' FIRE ACCESS ROAD
17' TYP.
35
'
T
Y
P
SCALE: 1"= 30'ENLARGED SITE PLAN3 LEGEND AND NOTES1
SCALE: 1"= 500'KEY MAP2
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
0
SCALE: 1"=30' (Horiz.)
60'30'30'
CS104
ENLARGED SITE
PLAN
SURFACE MATERIAL LEGEND:
ASPHALT PAVEMENT
CONCRETE
8" BABC STONE
NOTES:
- ALL CURB TO BE SPILL CURB UNLESS NOTED
DIFFERENTLY ON PLAN
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
8W
8W
8W
8W
8W
8W
8W
8W
8W
B
L
U
E
C
L
A
Y
R
O
A
D
TAXIWAY
C
E
N
T
E
R
L
I
N
E
+
-
TAXIWAY
O
B
J
E
C
T
F
R
E
E
Z
O
N
E
C
S
X
T
R
A
N
S
P
O
R
T
A
T
I
O
N
R
A
I
L
R
O
A
D
C
E
N
T
E
R
L
I
N
E
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXX
X
XXXXXXXXXXXXXXXX
GW
GW
T
G
W
GW
CO
XXXXXXXX
XXXXXXXXXXXXXXX
X
X
X
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
GATE
GATE
GATE
WET
A
R
E
A
DROP INLET
RIM:26.30'
INV.:19.42' 48" RCP
GA
R
D
N
E
R
D
R
I
V
E
24
28
24
28
28
28
26
27
27 25
2628
32
31
30
29
27
27
27
27
2
8
2727
27
27
27
27
27 28
26
26
27
27
2627
27
3
0
2
8
2
9
31
P
P
TEMPORARY
CONSTRUCTION ENTRANCE
(TYP)
SILT FENCE (TYP)
TEMPORARY SEDIMENT
SKIMMER BASIN (TSB-2)
WITH FAIRCLOTH SKIMEMR
TEMPORARY SEDIMENT
SKIMMER BASIN (TSB-1)
WITH FAIRCLOTH SKIMEMR
TEMPORARY
DIVERSION DITCH (TDD-1)
TEMPORARY
DIVERSION DITCH (TDD-2)
TREE PROTECTION
FENCING (TYP)
TEMPORARY DIVERSION
DITCH (TDD-3)
TEMPORARY WATTLE /
CHECK DAM (TYP)
PROPOSED
30" RCP
CONNECT TO
EXISTING DROP INLET
STRUCTURE
INSTALL DROP INLET WITH
INLET PROTECTION PRIOR TO
REGRADING EXISTING DITCH
SILT FENCE (TYP)
TEMPORARY
INLET PROTECTION
(TYP.)
DRAINAGE AREA (TSB-1)
12.45 ACRES
DRAINAGE AREA (TSB-2)
4.84 ACRES
SILT FENCE (TYP)
EXISTING CLOSED TOP
STORM STRUCTURE
TEMPORARY DITCH PLUG
(WILL REDIRECT EXISTING DRAINAGE
TO THE TEMPORARY DIVERSION DITCH
UNTIL PERMANENT GRADES ARE ESTABLISHED)
RIPRAP OUTLET
PROTECTION FOR TSB-2
RIPRAP OUTLET
PROTECTION FOR TSB-1
TEMPORARY PUMP AROUND
SILT SACK
EXISTING TWIN 36" RCP
DRAINAGE PIPES
TEMPORARY
CONSTRUCTION ENTRANCE
(TYP)
TEMPORARY CHECK DAM
LEGEND AND NOTES1SCALE: 1"= 100'SEDIMENT AND EROSION CONTROL - PHASE 12
0
SCALE: 1"=100' (Horiz.)
200'100'100'
GENERAL EROSION CONTROL NOTES
1.SEE G002 / CE502 - EROSION AND SEDIMENT CONTROL MAINTENANCE
NOTES AND NCG01 GROUND STABILIZATION AND MATERIALS HANDLING
FOR REQUIREMENT MAINTENANCE OF EROSION AND SEDIMENT
CONTROL MEASURES
2.WHERE SILT FENCE IS REQUIRED IN THE SAME PLACE AS TREE
PROTECTION FENCING, ORANGE SILT FENCE AND SIGNAGE FOR TREE
PROTECTION MAY BE USED INSTEAD OF DUPLICATE FENCING. SIGNAGE
MUST MEET NEW HANOVER COUNTY REQUIREMENTS FOR TREE
PROTECTION DURING CONSTRUCTION.
3.SILT FENCE AND/OR TREE PROTECTION FENCE TO BE PLACED AT OR
INSIDE LIMITS OF DISTURBANCE. THE PLANS ILLUSTRATE THE FENCING
AS AN OFFSET FROM THE LIMITS OF DISTURBANCE FOR GRAPHIC
CLARITY.
4.THE LIMITS OF DISTURBANCE LINE HAS BEEN SHOW AS AN OFFSET
FROM THE SILT FENCING LINE FOR GRAPHIC CLARITY.
5.ANY GRADING BEYOND THE DENUDED LIMITS SHOWN ON THE PLAN IS A
VIOLATION OF THE COUNTY EROSION CONTROL ORDINANCE AND IS
SUBJECT TO A FINE.
6.GRADING MORE THAN ONE ACRE WITHOUT AN APPROVED EROSION
CONTROL PLAN IS A VIOLATION OF STATE LAW AND IS SUBJECT TO A
FINE.
7.NO WETLANDS AND/OR JURISDICTIONAL STREAMS ARE TO BE IMPACTED
PRIOR TO APPROVAL FROM THE DWR AND USACE.
8.GROUND COVER MUST BE PROVIDED ON EXPOSED SLOPES WITHIN 21
CALENDAR DAYS FOLLOWING COMPLETION OF ANY PHASE OF GRADING;
AND, A PERMANENT GROUND COVER FOR ALL DISTURBED AREAS
WITHIN 15 WORKING DAYS OR 90 CALENDAR DAYS (WHICHEVER IS
SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR
DEVELOPMENT.
9.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE
REQUIRED BY A REPRESENTATIVE OF NEW HANOVER COUNTY.
10.SLOPES SHALL BE GRADED NO STEEPER THAN 3:1.
11.ADDITIONAL DEVICES MAY BE REQUIRED AS AGREED UPON BY THE
FIELD INSPECTOR, ENGINEER, AND OWNER.
12.IF ACTIVE CONSTRUCTION CEASES IN ANY AREA FOR MORE THAN 15
WORKING DAYS OR 90 CALENDAR DAYS (WHICHEVER IS SHORTER), ALL
DISTURBED AREAS MUST BE SEEDED, MULCHED, AND TACKED.
13.WITHIN 24 HOURS FOLLOWING ANY RAIN EVENT, THE CONTRACTOR
SHALL INSPECT AND REPAIR, AS NECESSARY, ALL DAMAGED EROSION
CONTROL MEASURES.
14.ALL ACTIVITY AND INSTALLATION OF EROSION CONTROL MATTING WILL
BE COMPLETE PRIOR TO ANY RAIN EVENT.
LIMITS OF DISTURBANCE
AREA: 35.50 AC
CONSTRUCTION ENTRANCE
EROSION CONTROL SYMBOLS
SILT FENCESFSFSF
LIMITS OF DISTURBANCELODLODLOD
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
CE101
SEDIMENT AND
EROSION CONTROL -
PHASE 1
P
P
TEMPORARY
INLET PROTECTION
(TYP.)
TEMPORARY
INLET PROTECTION
(TYP.)
CULVERT
NOT TO BE INSTALLED
UNTIL IMPACTS ARE
APPROVED BY USACE
PUMP AROUND (TO BE
MOVED PRIOR TO
EACH CULVERT BEING
CONSTRUCTED)
SILT SACK
26
27
27
25
2627
28
29
28
TEMPORARY
CONSTRUCTION ENTRANCE
(MAINTAINED FROM PHASE 1)
TEMPORARY SEDIMENT
SKIMMER BASIN (TSB-2)
(MAINTAINED FROM PHASE 1)
TEMPORARY
CONSTRUCTION ENTRANCE
(MAINTAINED FROM PHASE 1)
36" RCP
(44LF @ 0.32%)
36" RCP
(170LF @ 0.30%)
48" RCP
(93LF @ 0.30%)
CULVERT NOT TO BE
INSTALLED
UNTIL IMPACTS ARE
APPROVED BY USACE
CULVERT NOT TO BE
INSTALLED
UNTIL IMPACTS ARE
APPROVED BY USACE
EXISTING WETLANDS
NOT TO BE DISTURBED
UNTIL IMPACTS ARE
APPROVED BY USACE
SILT FENCE (TYP)
SILT FENCE (TYP)
TEMPORARY
INLET PROTECTION
(TYP.)
LEGEND AND NOTES1SCALE: 1"= 100'SEDIMENT AND EROSION CONTROL - PHASE 22
0
SCALE: 1"=100' (Horiz.)
200'100'100'
GENERAL EROSION CONTROL NOTES
1.SEE 5/C12.0 - EROSION AND SEDIMENT CONTROL MAINTENANCE NOTES
AND NCG01 GROUND STABILIZATION AND MATERIALS HANDLING FOR
REQUIREMENT MAINTENANCE OF EROSION AND SEDIMENT CONTROL
MEASURES
2.WHERE SILT FENCE IS REQUIRED IN THE SAME PLACE AS TREE
PROTECTION FENCING, ORANGE SILT FENCE AND SIGNAGE FOR TREE
PROTECTION MAY BE USED INSTEAD OF DUPLICATE FENCING. SIGNAGE
MUST MEET NEW HANOVER COUNTY REQUIREMENTS FOR TREE
PROTECTION DURING CONSTRUCTION.
3.SILT FENCE AND/OR TREE PROTECTION FENCE TO BE PLACED AT OR
INSIDE LIMITS OF DISTURBANCE. THE PLANS ILLUSTRATE THE FENCING
AS AN OFFSET FROM THE LIMITS OF DISTURBANCE FOR GRAPHIC
CLARITY.
4.THE LIMITS OF DISTURBANCE LINE HAS BEEN SHOW AS AN OFFSET
FROM THE SILT FENCING LINE FOR GRAPHIC CLARITY.
5.ANY GRADING BEYOND THE DENUDED LIMITS SHOWN ON THE PLAN IS A
VIOLATION OF THE COUNTY EROSION CONTROL ORDINANCE AND IS
SUBJECT TO A FINE.
6.GRADING MORE THAN ONE ACRE WITHOUT AN APPROVED EROSION
CONTROL PLAN IS A VIOLATION OF STATE LAW AND IS SUBJECT TO A
FINE.
7.NO WETLANDS AND/OR JURISDICTIONAL STREAMS ARE TO BE IMPACTED
PRIOR TO APPROVAL FROM THE DWR AND USACE.
8.GROUND COVER MUST BE PROVIDED ON EXPOSED SLOPES WITHIN 21
CALENDAR DAYS FOLLOWING COMPLETION OF ANY PHASE OF GRADING;
AND, A PERMANENT GROUND COVER FOR ALL DISTURBED AREAS
WITHIN 15 WORKING DAYS OR 90 CALENDAR DAYS (WHICHEVER IS
SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR
DEVELOPMENT.
9.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE
REQUIRED BY A REPRESENTATIVE OF NEW HANOVER COUNTY.
10.SLOPES SHALL BE GRADED NO STEEPER THAN 3:1.
11.ADDITIONAL DEVICES MAY BE REQUIRED AS AGREED UPON BY THE
FIELD INSPECTOR, ENGINEER, AND OWNER.
12.IF ACTIVE CONSTRUCTION CEASES IN ANY AREA FOR MORE THAN 15
WORKING DAYS OR 90 CALENDAR DAYS (WHICHEVER IS SHORTER), ALL
DISTURBED AREAS MUST BE SEEDED, MULCHED, AND TACKED.
13.WITHIN 24 HOURS FOLLOWING ANY RAIN EVENT, THE CONTRACTOR
SHALL INSPECT AND REPAIR, AS NECESSARY, ALL DAMAGED EROSION
CONTROL MEASURES.
14.ALL ACTIVITY AND INSTALLATION OF EROSION CONTROL MATTING WILL
BE COMPLETE PRIOR TO ANY RAIN EVENT.
LIMITS OF DISTURBANCE
AREA: 35.50 AC
CONSTRUCTION ENTRANCE
EROSION CONTROL SYMBOLS
SILT FENCE
LIMITS OF DISTURBANCE
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
CE102
SEDIMENT AND
EROSION CONTROL -
PHASE 2
INLET PROTECTION
B
L
U
E
C
L
A
Y
R
O
A
D
TAXIWAY
C
E
N
T
E
R
L
I
N
E
+
-
TAXIWAY
O
B
J
E
C
T
F
R
E
E
Z
O
N
E
C
S
X
T
R
A
N
S
P
O
R
T
A
T
I
O
N
R
A
I
L
R
O
A
D
C
E
N
T
E
R
L
I
N
E
30.0
'
UTI
L
I
T
Y
E
A
S
E
M
E
N
T
50.0
'
BU
I
L
D
I
N
G
S
E
T
B
A
C
K
WET
A
R
E
A
DROP INLET
RIM:26.30'
INV.:19.42' 48" RCP
GA
R
D
N
E
R
D
R
I
V
E
46,623 SF
SHIPPING /
RECEIVING
123,596 SF
CONTROLLED
AMBIENT
232,492 SF
2 - 8 DEGREES
CELCIUS
5,657 SF
FREEZER FARM
COMPACTOR
COMPACTOR
15,896 SF
CORRIDOR
QU
A
R
A
N
T
I
N
E
DEA CAGE
DRIVE-IN RAMP
58,576 SF
-20 DEGREES
WALK-IN
10' x 10' DOOR
12' x 14'
DRIVE-IN
DOOR, TYP.
12' x 14'
DRIVE-IN
DOOR, TYP.
12' x 14'
DRIVE-IN
DOOR, TYP.
12' x 14'
DRIVE-IN
DOOR, TYP.
9' x 10' DOCK
DOOR, TYP.
10' x 10' DOOR 10' x 10' DOOR
10' x 10' DOOR
10' x 10' DOOR
10' x 10' DOOR
10' x 10' DOOR
DEA CAGE
AIR SIDE AIR SIDE
LA
N
D
S
I
D
E
LA
N
D
S
I
D
E
(200) ULT
REFRIGERATORS
FORKLIFT
CHARGING AREA
FORKLIFT
CHARGING
AREA
SCRUBBER DUMP +
PALLET CLEANING
TRASH AREA
GOWNING AREA
GOWNING AREA
GOWNING AREA
2,924 SF
MAINT. SHOP
FUTURE
FREEZER
FARM AREA
10' x 10' DOOR
10' x 10' DOOR
10' x 10' DOOR
GENERATOR
YARD
GENERATOR
YARD
501 SF
ELECTRICAL
501 SF
ELECTRICAL
501 SF
ELECTRICAL
501 SF
ELECTRICAL
521 SF
FIRE PUMP
VANVAN
VA
N
VA
N
28
26
2
6
28
26
2
7
2
7
28
27
27
27 25
2628
32
31
30
29
30 28
27
2
6
28
27
27
27
2
8
2727
27
27
27
27
27 28
25 22232426
26
26
27
27
2627
27
3
0
2
8
2
9
31
27
27
25
21222324
26
26
27
PROJECT AREA = 31.32 ACRES
BUILT-UPON AREA = 917,384 SF
%IMPERVIOUS = 67.24%
SCALE: 1"= 100'OVERALL GRADING AND DRAINAGE PLAN2 LEGEND AND NOTES1
0
SCALE: 1"=100' (Horiz.)
200'100'100'
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
CG100
OVERALL
GRADING AND
DRAINAGE PLAN
750' BUILDING RESTRICTION LINE (35' BUILDING HEGHT LINE)
GA
R
D
N
E
R
D
R
I
V
E
VA
N
28
2
6
28
26
2
7
2
7
28
27
2
6
28
27
27
25
222324
26
26
26
27
27
26
DI-12
RIM=25.25'
INV IN E=19.93'
INV OUT W=19.93'
36
"
R
C
P
(5
8
L
F
@
0
.
1
0
%
)
36"
R
C
P
(54
L
F
@
0
.
1
7
%
)
36" RCP
(95LF @ 0.13%)
36" RCP
(322LF @ 0.10%)
36
"
R
C
P
(5
8
L
F
@
0
.
1
0
%
)
DI-13
RIM=25.75'
INV IN E=19.87'
INV OUT W=19.87'
DI-14
RIM=26.25'
INV IN E=19.81'
INV OUT SW=19.81'
DI-11
RIM=24.82'
INV IN NE=19.99'
INV OUT W=19.99'
DI-9
RIM=25.80'
INV IN N=20.47'
INV OUT S=20.47'
DI-7
RIM=27.68'
INV IN N=20.91'
INV OUT S=20.91'
DI-16
RIM=27.35'
INV IN NE=19.70'
INV IN N=19.70'
INV OUT S=19.70'
EX. DI
RIM=26.30'
INV IN N=19.42'
DI-8
RIM=27.38'
INV IN N=20.59'
INV OUT S=20.59'
PROPOSED BUILDING
509,000 SF
FFE = 28.50'
36
"
R
C
P
(5
8
L
F
@
0
.
1
0
%
)
3
6
"
R
C
P
(
9
0
L
F
@
0
.
0
7
%
)
DI-10
RIM=26.76'
INV IN N=20.38'
INV OUT SW=20.05'
42"
R
C
P
(284
L
F
@
0
.
1
0
%
)
36
"
R
C
P
(1
7
0
L
F
@
0
.
1
3
%
)
36
"
R
C
P
(7
0
L
F
@
0
.
1
7
%
)
FES-1
INV.=21.45
COLLAR AND EXTEND
EXISTING 36" RCP
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
SCALE: 1"= 30'ENLARGED GRADING AND DRAINAGE PLAN3 LEGEND AND NOTES1
SCALE: NTSKEY MAP2
0
SCALE: 1"=30' (Horiz.)
60'30'30'
CG101
ENLARGED GRADING
AND DRAINAGE PLAN
B
L
U
E
C
L
A
Y
R
O
A
D
750' BUILDING RESTRICTION LINE (35' BUILDING HEGHT LINE)
C
S
X
T
R
A
N
S
P
O
R
T
A
T
I
O
N
R
A
I
L
R
O
A
D
C
E
N
T
E
R
L
I
N
E
VANVAN
VA
N
27
27
25
26
28
32
31
30
29
30
28
27
27
2
8
2727
27
27
27
27
27 28
27
27
3
0
2
8
2
9
31
27
27
ADS DURASLOT
SLOTTED DRAIN (TYP)
NYLOPLAST
CATCH BASIN
(TYP)
NYLOPLAST
CATCH BASIN
(TYP)
36" RCP
(368LF @ 0.11%)
30" RCP
(475LF @ 0.10%)
30
"
R
C
P
(4
2
L
F
@
0
.
1
0
%
)
30"
R
C
P
(28
L
F
@
0
.
1
1
%
)
24" RCP
(57LF @ 0.10%)
DI-4
RIM=27.67'
INV IN W=21.76'
INV OUT S=21.76'
DI-6
RIM=28.03'
INV IN E=21.30'
INV IN N=21.30'
INV OUT S=21.30'
DI-3
RIM=26.80'
INV IN S=21.80'
INV OUT E=21.80'
PROPOSED BUILDING
509,000 SF
FFE = 28.50'
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
SCALE: 1"= 30'ENLARGED GRADING AND DRAINAGE PLAN3 LEGEND AND NOTES1
SCALE: NTSKEY MAP2
0
SCALE: 1"=30' (Horiz.)
60'30'30'
CG102
ENLARGED GRADING
AND DRAINAGE PLAN
26
27
27
25
21
22
23
24
26
26
ADS DURASLOT
SLOTTED DRAIN (TYP)NYLOPLAST
CATCH BASIN
(TYP)
NYLOPLAST
CATCH BASIN
(TYP)
OPEN THROAT
CATCH BASIN
RIM = 22.5
30
"
R
C
P
(1
6
6
L
F
@
0
.
1
1
%
)
30" RCP
(380LF @ 2.29%)
Structure - (65)
RIM=26.18'
INV IN N=12.97'
SCALE: 1"= 30'ENLARGED GRADING AND DRAINAGE PLAN3 LEGEND AND NOTES1
SCALE: NTSKEY MAP2
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
0
SCALE: 1"=30' (Horiz.)
60'30'30'
CG103
ENLARGED GRADING
AND DRAINAGE PLAN
WETLAND
VANVAN
VA
N
VA
N
B
L
U
E
C
L
A
Y
R
O
A
D
TAXIWA
Y
C
E
N
T
E
R
L
I
N
E
+
-
TAXIWA
Y
O
B
J
E
C
T
F
R
E
E
Z
O
N
E
C
S
X
T
R
A
N
S
P
O
R
T
A
T
I
O
N
R
A
I
L
R
O
A
D
C
E
N
T
E
R
L
I
N
E
30.0
'
UTI
L
I
T
Y
E
A
S
E
M
E
N
T
50.0
'
BU
I
L
D
I
N
G
S
E
T
B
A
C
K
WET
A
R
E
A
DROP INLET
RIM:26.30'
INV.:19.42' 48" RCP
GA
R
D
N
E
R
D
R
I
V
E
EXISTING 6" FORCE MAIN
PROPOSED 12" PVC
C-900 WATER MAIN
PROPOSED 6" PVC
C900 FORCE MAIN
12"x12"x10" MJ TEE
(1) 12" GV
(1) 10" GV
EXISTING 12"
WATER MAIN
CONNECT TO EXISTING 6"
FORCE MAIN
EXISTING 12" FORCE MAIN
EXISTING 12" WATER MAIN
30.00' UTILITY
EASEMENT
12" TS&V
PROPOSED 2" PVC
FORCE MAIN
10.00' HORIZONTAL
SEPARATION
8" PVC C-900 FIRE SERVICE LOOP
FOR HYDRANTS
SANITARY SEWER SERVICE
(GRAVITY)
PROPOSED 24" FORCE MAIN
(BY OTHERS)
PROPOSED 24" FORCE MAIN
(BY OTHERS)
PROPOSED 12" WATER MAIN
(BY OTHERS)
PROPOSED 6" PVC
C900 FORCE MAIN
PROPOSED 12" PVC
C-900 WATER MAIN
TIE TO EXISTING 8" WATER MAIN
12"x8" REDUCER
PROPOSED 24" FORCE MAIN
(BY OTHERS)
CONNECT PROPOSED
2" PVC FORCE MAIN TO
EXISTING GRAVITY
SEWER MANHOLE
EXISTING 6" PVC
FORCE MAIN
PROPOSED 2"
FORCE MAIN
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
SCALE: 1"= 100'OVERALL UTILITIES PLAN1
0
SCALE: 1"=100' (Horiz.)
200'100'100'
CU100
OVERALL UTILITIES
PLAN
VA
N
PROPOSED 12" PVC
C-900 WATER MAIN
PROPOSED 6" PVC C900
FORCE MAIN REALIGNMENT
12"x3" MJ TEE
(1) 3" GV
FIRE HYDRANT
(TYP.)
SANITARY SEWER
CLEANOUT (TYP.)
SSMH-6
RIM = 27.65'
INV IN = 22.38' (SSMH-7)
INV OUT = 22.38'
6" C-900 287.66'
6" C-9
0
0
1
0
5
.
9
1
'
SSMH-7
RIM = 26.28'
INV IN = 23.56' (Structure - (53))
INV OUT = 23.56'
6" C
-
9
0
0
7
1
.
6
4
'
SSMH-8
RIM = 27.56'
INV IN = 24.97' (CO-3)
INV OUT = 24.97'
6"
C
-
9
0
0
1
2
7
.
0
9
'
CO-3
RIM = 28.39'
INV OUT = 25.73'
PROPOSED 24" FORCE MAIN
(BY OTHERS)
30.00' UTILITY EASEMENT
PROPOSED 24" FORCE MAIN
(BY OTHERS)
PROPOSED 2" PVC
FORCE MAIN
10.00' HORIZONTAL SEPARATION
3" WATER METER WITH
CONCRETE VAULT
3" PVC C-900
COMMERCIAL
WATER SERVICE
4" PVC C-900
FIRE SERVICE TO
SPRINKLER SYSTEM
8" PVC C-900 FIRE SERVICE
LOOP FOR HYDRANTS
PROPOSED 12" PVC
C-900 WATER MAIN
8" PVC C-900 FIRE SERVICE
LOOP FOR HYDRANTS
SANITARY SEWER SERVICE
(GRAVITY)
8"x4" MJ TEE
(1) 4" GV
EXISTING 6" PVC
FORCE MAIN
PROPOSED 6" PVC
FORCE MAIN
REALIGNMENT
6" GV
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
SCALE: 1"= 30'ENLARGED UTILITIES PLAN3 LEGEND AND NOTES1
SCALE: NTSKEY MAP2
0
SCALE: 1"=30' (Horiz.)
60'30'30'
CU101
ENLARGED UTILITIES
PLAN
PROPOSED UTILITIES LEGEND
WATER LINE
FIRE HYDRANT
WATER VALVE
WATER METER
WATER CROSSING
WATER TEE
SANITARY SEWER
SANITARY SEWER MANHOLE
SANITARY SEWER CLEAN OUT
SANITARY FORCE MAIN
UTILITY EASEMENT
B
L
U
E
C
L
A
Y
R
O
A
D
C
S
X
T
R
A
N
S
P
O
R
T
A
T
I
O
N
R
A
I
L
R
O
A
D
C
E
N
T
E
R
L
I
N
E
30.0
'
UTI
L
I
T
Y
E
A
S
E
M
E
N
T
50.0
'
BU
I
L
D
I
N
G
S
E
T
B
A
C
K
VANVAN
VA
N
EXISTING 12"
WATER MAIN
EXISTING 12"
FORCE MAIN
FIRE HYDRANT
ASSEMBLY (TYP)
EXISTING 12" FORCE MAIN
EXISTING 12" WATER MAIN
SANITARY SEWER
CLEANOUT
CO-1
RIM = 28.35'
INV OUT = 20.67'
6"
C
-
9
0
0
1
1
4
.
7
1
'
SSMH-4
RIM = 27.54'
INV IN = 20.27' (CO-1)
INV OUT = 20.27'
6" C-900 35.77'
SSMH-3
RIM = 27.04'
INV IN = 19.43' (SSMH-4)
INV OUT = 19.43'
6" C-900 93.00'
6" C-900 287.66'
SSMH-1
RIM = 26.69'
INV IN = 19.43' (SSMH-5)
INV IN = 18.72' (SSMH-3)
INV OUT = -4.69'
12" TS&V
SANITARY SEWER
GRINDER PUMP STATION
8"x8" MJ TEE
(1) 8" GV
PROPOSED 24" FORCE MAIN
(BY OTHERS)
8" PVC C-900 FIRE SERVICE
LOOP FOR HYDRANTS
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
SCALE: 1"= 30'ENLARGED UTILITIES PLAN3 LEGEND AND NOTES1
SCALE: NTSKEY MAP2
0
SCALE: 1"=30' (Horiz.)
60'30'30'
CU102
ENLARGED UTILITIES
PLAN
PROPOSED UTILITIES LEGEND
WATER LINE
FIRE HYDRANT
WATER VALVE
WATER METER
WATER CROSSING
WATER TEE
SANITARY SEWER
SANITARY SEWER MANHOLE
SANITARY SEWER CLEAN OUT
SANITARY FORCE MAIN
UTILITY EASEMENT
750' BUILDING RESTRICTION LINE (35' BUILDING HEGHT LINE)
EXISTING 6" FORCE MAIN
2 @ 45° MJ BENDS
CONNECT TO EXISTING
6" FORCE MAIN
FIRE HYDRANT
ASSEMBLY (TYP)
PROPOSED 24" FORCE MAIN
(BY OTHERS)
PROPOSED 12" WATER MAIN
(BY OTHERS)
PROPOSED 6"
C900 FORCE MAIN
REALIGNMENT
SCALE: 1"= 30'ENLARGED UTILITIES PLAN3 LEGEND AND NOTES1
SCALE: NTSKEY MAP2
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
0
SCALE: 1"=30' (Horiz.)
60'30'30'
CU103
ENLARGED UTILITIES
PLAN
PROPOSED UTILITIES LEGEND
WATER LINE
FIRE HYDRANT
WATER VALVE
WATER METER
WATER CROSSING
WATER TEE
SANITARY SEWER
SANITARY SEWER MANHOLE
SANITARY SEWER CLEAN OUT
SANITARY FORCE MAIN
UTILITY EASEMENT
TAXIWA
Y
O
B
J
E
C
T
F
R
E
E
Z
O
N
E
750' BUILDING RESTRICTION LINE (35' BUILDING HEGHT LINE)750' BUILDING RESTRICTION LINE (35' BUILDING HEGHT LINE)
2 @ 45° MJ BENDS
FIRE HYDRANT
ASSEMBLY (TYP)
SCALE: 1"= 30'ENLARGED UTILITIES PLAN3 LEGEND AND NOTES1
SCALE: NTSKEY MAP2
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
0
SCALE: 1"=30' (Horiz.)
60'30'30'
CU104
ENLARGED UTILITIES
PLAN
PROPOSED UTILITIES LEGEND
WATER LINE
FIRE HYDRANT
WATER VALVE
WATER METER
WATER CROSSING
WATER TEE
SANITARY SEWER
SANITARY SEWER MANHOLE
SANITARY SEWER CLEAN OUT
SANITARY FORCE MAIN
UTILITY EASEMENT
DROP INLET
RIM:26.30'
INV.:19.42' 48" RCP
GA
R
D
N
E
R
D
R
I
V
E
EXISTING 8" WATER MAIN
PROPOSED 12" PVC
C-900 WATER MAIN
TIE TO EXISTING 8" WATER MAIN
12"x8" REDUCER
PROPOSED 24" FORCE MAIN
(BY OTHERS)
CONNECT PROPOSED
2" PVC FORCE MAIN TO
EXISTING GRAVITY
SEWER MANHOLE
EXISTING 6" PVC
FORCE MAIN
PROPOSED 2" PVC
FORCE MAIN
SCALE: 1"= 30'ENLARGED UTILITIES PLAN3 LEGEND AND NOTES1
SCALE: NTSKEY MAP2
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
0
SCALE: 1"=30' (Horiz.)
60'30'30'
CU105
ENLARGED UTILITIES
PLAN
PROPOSED UTILITIES LEGEND
WATER LINE
FIRE HYDRANT
WATER VALVE
WATER METER
WATER CROSSING
WATER TEE
SANITARY SEWER
SANITARY SEWER MANHOLE
SANITARY SEWER CLEAN OUT
SANITARY FORCE MAIN
UTILITY EASEMENT
30.0
'
UTI
L
I
T
Y
E
A
S
E
M
E
N
T
50.0
'
BU
I
L
D
I
N
G
S
E
T
B
A
C
K
GATE
WET
A
R
E
A
VANVAN
VA
N
VA
N
TRAILER STORAGE
15' X 55'
EMPLOYEE LOT
111 SPACES
2 HANDICAP SPACES
TOTAL SPACES: 113
26' DRIVE
EMPLOYEE/VISITOR LOT
126 SPACES
5 ADA SPACES
TOTAL SPACES: 131
30' DRIVE
FOUNDATION
PLANTING
BEDS
FOUNDATION
PLANTING
BEDS
FOUNDATION
PLANTING
BEDS
PROPOSED BUILDING
509,000 SF
EXISTING RUNWAY
WETLAND
TRUCK RECEIVING
AND DELIVERY
WETLAND
TREES BOTANICAL NAME COMMON NAME
ACER BUERGERIANUM TRIDENT MAPLE
MAGNOLIA GRANDIFLORA CLITTLE GEMC DWARF SOUTHERN MAGNOLIA
QUERCUS VIRGINIANA SOUTHERN LIVE OAK
SHRUBS BOTANICAL NAME COMMON NAME
ABELIA X GRANDIFLORA CKALEIDOSCOPEC GLOSSY ABELIA
AZALEA ENCORE ENCORE AZALEA
GARDENIA JASMINOIDES CFROSTPROOFC FROSTPROOF GARDENIA
ILEX CORNUTA CDWARF BURFORDC DWARF BURFORD HOLLY
ITEA VIRGINICA CHENRYCS GARNETC HENRYCS GARNET SWEETSPIRE
MUHLENBERGIA CAPILLARIS PINK MUHLY GRASS
OSMANTHUS X FORTUNEI SWEET OLIVE
PANICUM VIRGATUM 'SHENANDOAH'SHENANDOAH SWITCH GRASS
PLANT SCHEDULE
LEGEND AND NOTES1SCALE: 1"= 100'OVERALL LANDSCAPE PLAN2
0
SCALE: 1"=100' (Horiz.)
200'100'100'
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
CL100
OVERALL
LANDSCAPE PLAN
LANDSCAPE DATA
REGULATION REQUIRED PROPOSED
FOUNDATION PLANTING LANDSCAPING (SEC. 5.4.6-B)
FOUNDATION PLANTING AREA SHALL BE A MINIMUM OF 12%
OF THE AREA OF THE BUILDING FACE ADJACENT TO
PARKING AREA OR INTERNAL DRIVE.
BUILDING FACADE: 124,125SF
124,125SF X (0.12) = 14,895SF
FOUNDATION PLANTING BED TOTAL: 14,895SF
14,895SF 14,938SF
VA
N
26' DRIVE
24" CONCRETE CURB & GUTTER (TYP)
26' FIRE ACCESS ROAD
FOUNDATION
PLANTING BED
3470SF
FOUNDATION
PLANTING BED
470SF
FOUNDATION
PLANTING BED
6208SF
FOUNDATION
PLANTING BED
86F
FOUNDATION
PLANTING BED
169SF
5
20
20
20
20
14
14
9
9
581 SF581 SF
581 SF581 SF
581 SF581 SF
581 SF581 SF
EMPLOYEE/VISITOR LOT
126 SPACES
5 ADA SPACES
TOTAL SPACES: 131
TREES BOTANICAL NAME COMMON NAME
ACER BUERGERIANUM TRIDENT MAPLE
MAGNOLIA GRANDIFLORA CLITTLE GEMC DWARF SOUTHERN MAGNOLIA
QUERCUS VIRGINIANA SOUTHERN LIVE OAK
SHRUBS BOTANICAL NAME COMMON NAME
ABELIA X GRANDIFLORA CKALEIDOSCOPEC GLOSSY ABELIA
AZALEA ENCORE ENCORE AZALEA
GARDENIA JASMINOIDES CFROSTPROOFC FROSTPROOF GARDENIA
ILEX CORNUTA CDWARF BURFORDC DWARF BURFORD HOLLY
ITEA VIRGINICA CHENRYCS GARNETC HENRYCS GARNET SWEETSPIRE
MUHLENBERGIA CAPILLARIS PINK MUHLY GRASS
OSMANTHUS X FORTUNEI SWEET OLIVE
PANICUM VIRGATUM 'SHENANDOAH'SHENANDOAH SWITCH GRASS
PLANT SCHEDULE
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
LEGEND AND NOTES1
SCALE: 1"= 500'KEY MAP2
0
SCALE: 1"=30' (Horiz.)
60'30'30'
CL101
ENLARGED
LANDSCAPE PLAN
LANDSCAPE DATA
REGULATION REQUIRED PROPOSED
FOUNDATION PLANTING LANDSCAPING (SEC. 5.4.6-B)
FOUNDATION PLANTING AREA SHALL BE A MINIMUM OF
12% OF THE AREA OF THE BUILDING FACE ADJACENT TO
PARKING AREA OR INTERNAL DRIVE.
BUILDING FACADE: 124,125SF
124,125SF X (0.12) = 14,895SF
FOUNDATION PLANTING BED TOTAL: 14,895SF
14,895SF 14,938SF
SCALE: 1"= 30'ENLARGED LANDSCAPE PLAN3
VANVAN
VA
N
TRAILER STORAGE
15' X 55'
FOUNDATION
PLANTING BED
624SF
FOUNDATION
PLANTING BED
660SF
FOUNDATION
PLANTING BED
660SF
FOUNDATION
PLANTING BED
605SF
FOUNDATION
PLANTING BED
305SF
FOUNDATION
PLANTING BED
1676SF
2020
14
8
9
14
10 10
14
8
TRUCK RECEIVING AND
DELIVERY AREA
PROPOSED
509,000 SF BUILDING
FFE=28.50'
581 SF581 SF 581 SF
581 SF
TRUCK LOADING DOCK
APRON
EMPLOYEE PARKING
111 SPACES
2 ADA SPACES
TOTAL SPACES: 113
TREES BOTANICAL NAME COMMON NAME
ACER BUERGERIANUM TRIDENT MAPLE
MAGNOLIA GRANDIFLORA CLITTLE GEMC DWARF SOUTHERN MAGNOLIA
QUERCUS VIRGINIANA SOUTHERN LIVE OAK
SHRUBS BOTANICAL NAME COMMON NAME
ABELIA X GRANDIFLORA CKALEIDOSCOPEC GLOSSY ABELIA
AZALEA ENCORE ENCORE AZALEA
GARDENIA JASMINOIDES CFROSTPROOFC FROSTPROOF GARDENIA
ILEX CORNUTA CDWARF BURFORDC DWARF BURFORD HOLLY
ITEA VIRGINICA CHENRYCS GARNETC HENRYCS GARNET SWEETSPIRE
MUHLENBERGIA CAPILLARIS PINK MUHLY GRASS
OSMANTHUS X FORTUNEI SWEET OLIVE
PANICUM VIRGATUM 'SHENANDOAH'SHENANDOAH SWITCH GRASS
PLANT SCHEDULE
SCALE: 1"= 30'ENLARGED LANDSCAPE PLAN3
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
0
SCALE: 1"=30' (Horiz.)
60'30'30'
CL102
ENLARGED
LANDSCAPE PLAN
LANDSCAPE DATA
REGULATION REQUIRED PROPOSED
FOUNDATION PLANTING LANDSCAPING (SEC. 5.4.6-B)
FOUNDATION PLANTING AREA SHALL BE A MINIMUM OF
12% OF THE AREA OF THE BUILDING FACE ADJACENT TO
PARKING AREA OR INTERNAL DRIVE.
BUILDING FACADE: 124,125SF
124,125SF X (0.12) = 14,895SF
FOUNDATION PLANTING BED TOTAL: 14,895SF
14,895SF 14,938SF
SCALE: 1"= 500'KEY MAP2
LEGEND AND NOTES1
NOTE: PAVEMENT SHALL BE CONSTRUCTED OF 4,000 PSI
CONCRETE. REINFORCEMENT SHALL BE #3S AT 18" ON
CENTER EACH WAY, AS INDICATED BELOW. SURFACE FINISHES
AND JOINTS SHALL BE AS INDICATED IN SPECIFICATIONS.
2"
12" COMPACTED, NON-RUTTING
SUBGRADE, COMPACTED 98% OF
THE STANDARD PROCTOR MAXIMUM
DRY DENSITY (ASTM D 698)
4" COMPACTED CABC
7" 4,000 PSI @ 28 DAYS CONCRETE
REINFORCED WITH #3S AT 18" O.C.E.W
CONSTRUCTION JOINT
EXPANSION JOINT
CONTROL JOINT
NOTES:
1.CONTROL JOINTS SHALL BE LOCATED APPROXIMATELY 5' O.C. AND
EQUIDISTANT.
2.EXTEND JOINT GROOVE 1" BELOW FINISH GRADE OR 25% OF
PAVEMENT THICKNESS WHICHEVER IS GREATER.
3.SEE DETAILS BELOW FOR EXPANSION JOINTS AND
CONSTRUCTION JOINTS.
1"
1
8"
1"
R1
8"
NOTES:
1.CONSTRUCTION JOINTS AS NEEDED AT CONTROL JOINT
LOCATIONS, SEE DETAIL ABOVE FOR LOCATIONS
2.EXTEND JOINT GROOVE 1" BELOW FINISH GRADE OR 25% OF
PAVEMENT THICKNESS WHICHEVER IS GREATER
3.SEE DETAIL BELOW FOR EXPANSION JOINTS AND ABOVE FOR
CONTROL JOINTS.
1
8"
R1
8"
1ST POUR 2ND POUR
1ST POUR 2ND POUR
1
2"
NOTES:
1.EXPANSION JOINTS SHALL BE LOCATED EVERY 50' MIN.
2.EXTEND EXPANSION JOINT 100% THROUGH PAVEMENT SURFACE.
3.ENSURE JOINTS ARE FREE OF NON-COMPRESSABLE MATERIALS
DURING INSTALLATION AND AFTER INSTALLATION.
4.SEE DETAIL AT TOP FOR CONTROL JOINTS AND ABOVE FOR
CONSTRUCTION JOINTS.
R1
8"
DECORATIVE CONCRETE
PAVEMENT, SEE DETAIL 10/CS501
SAW-CUT JOINT GROOVE
SAW-CUT JOINT GROOVE
COMPACTED SUBGRADE,
98% OF THE STANDARD
PROCTOR MAXIMUM DRY
DENSITY (ASTM D 698)
1/2" PRE-FORMED
BITUMINOUS JOINT MATERIAL
5/8" BACKER ROD
SILICONE CAULK, COLOR TO
MATCH CONCRETE
DECORATIVE CONCRETE
PAVEMENT, SEE DETAIL 10/CS501
COMPACTED SUBGRADE,
98% OF THE STANDARD
PROCTOR MAXIMUM DRY
DENSITY (ASTM D 698)
BUTT JOINT
COMPACTED SUBGRADE,
98% OF THE STANDARD
PROCTOR MAXIMUM DRY
DENSITY (ASTM D 698)
6"
AGGREGATE
COURSE BASE
CONCRETE
12"
SECTION
ASPHALT
PAVEMENT, SEE
DETAIL 3/CS501
CONCRETE
PAVEMENT, SEE
DETAIL 2/CS501 REINFORCED WITH
#3S AT 18" O.C.E.W
COMPACTED 98% OF THE STANDARD
PROCTOR MAXIMUM DRY DENSITY
(ASTM D 698)
4" COMPACTED CABC, 98% OF
THE STANDARD PROCTOR
MAXIMUM DRY DENSITY
(ASTM D 698)
BEVEL CONCRETE 1". USE
HOT-POURED RUBBER
SEALANT AT JOINT.
4"
DRIVE AISLES
10
"
PARKING SPACES
6"
2"
NON-RUTTING , COMPACTED
SUBGRADE, 98 PERCENT OF THE
STANDARD PROCTOR MAXIMUM
DRY DENSITY (ASTM D 698)
S9.5B SURFACE COURSE
INSTALL 2 - 2" LIFTS
COMPACTED AGGREGATE
BASECOURSE,COMPACTED
TO MEET NCDOT DENSITY
REQUIREMENTS
S9.5B SURFACE COURSE
INSTALL 1 - 2" LIFT
COMPACTED AGGREGATE
BASECOURSE,COMPACTED
TO MEET NCDOT DENSITY
REQUIREMENTS
NON-RUTTING , COMPACTED
SUBGRADE, 98 PERCENT OF THE
STANDARD PROCTOR MAXIMUM
DRY DENSITY (ASTM D 698)
4"
TOP OF PAV'T.
SECTION
12"
6"6'1.5'
3'
1.5'
8"
12
"
6"
1/2" GALV. STEEL (2
REQ'D.)
1:
1
2
M
A
X
.
S
L
O
P
E
4'-
0
"
M
I
N
,
S
E
E
P
L
A
N
4'-0"
M
I
N
,
SEE
P
L
A
N
6'-0"
4'-0"
6'-0"
ISOMETRIC
NOT TO SCALE
A
A
6'-
0
"
NOTE: MAXIMUM RAMP RISE NOT
TO EXCEED 6".PAVEMENT JOINT, SEE
LAYOUT PLANS FOR
LOCATION AND TYPE
DECORATIVE CONCRETE
PAVEMENT, SEE DETAIL
9/C11.0
TURN DOWN CURB
SEE DETAIL 9/CS501
ASPHALT PAVEMENT,
SEE DETAIL 3/C11.0
NON-DOWELED
EXPANSION JOINT, SEE
DETAIL 1/C11.0
DETECTABLE WARNING
SURFACE, "ULINE" OR APPROVED
EQUIVALENT, 2' X 4' TRUNCATED
DOME PAD, WET SET AND
FASTEN PER MANUFACTURE
RECOMMENDATION, COLOR TO
BE BURGUNDY
CONCRETE RAMP
PLANTING AREA OR
LAWN AREA, SEE
LANDSCAPE PLANS
INTEGRAL CONCRETE CURB RAMP
EDGE PROTECTION, SIMILAR TO
CONCRETE CURB, SEE DETAIL
7/C11.0
1:12 MAX. SLOPE
SECTION A
3/4" = 1'-0"
COMPACTED SUBGRADE
AND/OR AGGREGATE BASE
PER GEOTECHNICAL
REPORT
PAVEMENT JOINT,
SEE LAYOUT PLANS
FOR LOCATION AND
TYPE
CONCRETE RAMP, SIMILAR
TO DECORATIVE
CONCRETE PAVEMENT,
SEE DETAIL 10/CS501
DETECTABLE WARNING SURFACE,
"ULINE" OR APPROVED EQUIVALENT,
2' X 4' TRUNCATED DOME PAD, WET
SET AND FASTEN PER
MANUFACTURE RECOMMENDATION,
COLOR TO BE CHOSEN BY
LANDSCAPE ARCHITECT
ASPHALT PAVEMENT, SEE
DETAIL 3/CS501
TURB DOWN CURB, SEE
DETAIL 12/CS501
NON-DOWELED
EXPANSION JOINT, SEE
DETAIL 1/CS501
INTEGRAL CONCRETE CURB
RAMP EDGE PROTECTION,
SIMILAR TO CONCRETE CURB,
SEE DETAIL 13/CS501
1:12
M
A
X
.
SLOP
E
6'-0"
6'-0"
A
A
1:12
M
A
X
.
SLO
P
E
1:
5
0
M
A
X
.
SL
O
P
E
4'-
0
"
M
I
N
,
S
E
E
P
L
A
N
ISOMETRIC
NOT TO SCALE
NOTE: MAXIMUM RAMP RISE NOT
TO EXCEED 6".
4'-0"
M
I
N
,
SEE
P
L
A
N
CONCRETE RAMP LANDING,
SIMILAR TO DECORATIVE
CONCRETE PAVEMENT, SEE
DETAIL, 1:48 SLOPE MAX. ANY
DIRECTION
INTEGRAL CURB SIMILAR
TO CONCRETE CURB AND
GUTTER
CONCRETE RAMP
ASPHALT
PAVEMENT, SEE
DETAIL 3/CS501
EXPANSION
JOINT, SEE
DETAIL 1/CS501
CONCRETE RAMP
TRANSITION CURB
INTEGRAL TRANSITION CURB
SIMILAR TO TRANSITION
CONCRETE CURB
PAVEMENT JOINT, SEE
LAYOUT PLANS FOR
LOCATION AND TYPE
TURN DOWN CURB,
SEE DETAIL 12/CS501
DETECTABLE WARNING
SURFACE, SEE PLAN
FOR LOCATIONS,
"ULINE" OR APPROVED
EQUIVALENT, 2' X 4'
TRUNCATED DOME PAD,
WET SET AND FASTEN
PER MANUFACTURE
RECOMMENDATION,
COLOR TO BE CHOSEN
BY LANDSCAPE
ARCHITECT
2% MAX. SLOPE
SECTION A
3/4" = 1'-0"
CONCRETE RAMP LANDING,
SIMILAR TO DECORATIVE
CONCRETE PAVEMENT, SEE
DETAIL 9/CS501
INTEGRAL CURB SIMILAR
TO CONCRETE CURB AND
GUTTER
CONCRETE RAMP BEYOND, SEE
ISOMETRIC
ASPHALT PAVEMENT, SEE
DETAIL 3/CS501
TURN DOWN CURB, SEE
DETAIL 12/CS501
EXPANSION JOINT,
SEE DETAIL 1/CS501
COMPACTED SUBGRADE,
98% OF THE STANDARD
PROCTOR MAXIMUM DRY
DENSITY (ASTM D 698)
WHITE
WHITE
SEE DETAIL
H.C. PARKING SIGN
BLUE ON H.C.
STALL SIDE
BLUE ON H.C.
STALL SIDE
8' MIN.5' or 8'
SEE PLAN
4"
2"
4"4"
2"
4"
18
'
M
I
N
.
FACE OF CURB
4" WHITE
18
'
STRIPES
9'
EDGE OF
PAVEMENT
WHITE
HANDICAP PARKING
STALL
TYPICAL
PARKING STALL
NOTE:
HANDICAP PARKING SIGNS SHALL BE CLEAR OF ANY
ACCESSIBLE CURB RAMPS AND FLARES
FACE OF CURB OR
BUILDING OR OPPOSING
PARKING STALL
SEE DETAIL
BOLLARD BASE
3"
3"
5'
NOTES:
1.ALL WALKWAYS SHALL MEET OR EXCEED GOVERNING MUNICIPALITIES
REQUIREMENTS.
2.SUBGRADE SHALL NOT CONTAIN ANY ORGANIC MATTER.
3.REFER TO 1/CS501 FOR PAVEMENT JOINT TYPES AND LOCATIONS
4.PER ADA REQUIREMENTS: MAXIMUM CROSS SLOPE OF WALKING SURFACE SHALL NOT
BE STEEPER THAN 1:48, MAXIMUM RUNNING SLOPE OF WALKING SURFACE SHALL NOT
BE STEEPER THAN 1:20, WALKING SURFACES ALONG AN ACCESSIBLE ROUTE STEEPER
THAN 1:20 REQUIRE RAMPS, RAMP RUNS WITH A RISE GREATER THAN 6" SHALL HAVE
HANDRAILS, RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12,
MAXIMUM RISE PER RAMP IS 30", LANDINGS MUST BE PROVIDED WHERE NECESSARY.
CONTRACTOR SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES.
5.WALKING SURFACES AT BUILDING ENTRANCES SHALL PROVIDE ADEQUATE
ACCESSIBLE MANEUVERING CLEARANCE, SEE ARCHITECTURAL DRAWINGS.
CONTRACTOR SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO
INSTALLATION.
PLAN
3/8" = 1'-0"
EQ
EQ
LIGHT BROOM
FINISH, SWEEP
PERPENDICULAR TO
PATH OF TRAVEL
SMOOTH TROWEL
EDGE
PAVEMENT JOINTS, SEE
DETAIL 1/CS501 FOR LOCATIONS
4"
SECTION
1 1/2" = 1'-0"
R1
2"
3,000 PSI CONCRETE @ 28 DAYS, SEE PLAN
ABOVE FOR FINISHES
1" AT ADJACENT PLANTING AREA (SHOWN) OR
FLUSH AT ADJACENT LAWN OR HARDSCAPE
COMPACTED SUBGRADE, 98 PERCENT OF THE
STANDARD PROCTOR MAXIMUM DRY DENSITY
(ASTM D 698)
6"
ASPHALT
3,000 PSI CONCRETE AT
28 DAYS
4"
4"
6 X 6 - W1.4 X W1.4
WELDED WIRE FABRIC
(2) #3 REBAR CONTINUOUS
COMPACTED
SUBGRADE 98%
STANDARD PROCTOR
CABC
NOTES:
1.PLACE CONTROL JOINTS
EVERY +/- 5' AND
EXPANSION JOINTS EVERY
+/- 30'. JOINTS TO BE
EQUIDISTANCE WITH
NEARLY 1:1 LENGTH TO
WIDTH RATIO.
2.FINISH CONCRETE TO
MATCH CONCRETE
SIDEWALK, SEE DETAIL
R12"
6"12"
10"
111
2"51
2"
6"
12"
R=1"
18"
1/2" FILLED EXPANSION JOINT
CONCTROL JOINT
(1/4" X 1" DEEP SCORE)
OBLIQUE VIEW
VERTICAL CURB AND GUTTER
111
2"51
2"
6"
12"
R=1"
18"
3
4"
R=1
2"
R=11
4"
R=1
2"
R=11
4"
3
4"
6"
12"
12"
6"
VERTICAL CURB AND GUTTER
(CATCH)
VERTICAL CURB AND GUTTER
(SPILL)
NOTES:
1. EXPANSION JOINT MATERIAL TO COMPLY WITH CURRENT NCDOT STANDARDS
2. 50' MAX EXPANSION JOINT SPACING, 10' MAX CONTRACTION JOINT SPACING
3. MINIMUM INSTALLATION LENGTH IS 5 FT.
4. CONCRETE TO BE 3000 PSI MIN
5. VERTICAL CURB AND GUTTER BASE CAN BE SLOPED 3/4" OR USE A FLAT BASE
6. SUBGRADE TO BE COMPACTED SUBGRADE, 98 PERCENT OF THE STANDARD
PROCTOR MAXIMUM DRY DENSITY (ASTM D 698)
AGGREGATE BASE
COURSE
AGGREGATE BASE
COURSE
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
SCALE: NTSPAVING JOINTS1 CS501
SITE DETAILS
SCALE: NTSHEAVY DUTY CONCRETE2
SCALE: NTSASPHALT PAVEMENT SECTIONS3
SCALE: NTSASPHALT TO CONCRETE TRANSITION4
SCALE: NTSWHEEL STOPS5
CURB RAMP NOTES:
1.ALL CURB RAMPS SHALL BE INSTALLED IN ACCORDANCE
WITH THE AMERICANS WITH DISABILITIES ACT (ADA) LATEST
EDITION.
2.ALL CONCRETE SHALL BE CLASS A WITH A 28 DAY BREAK
OF AT LEAST 3,000 PSI.
3.THE WALKING SURFACE OF THE RAMP SHALL HAVE A SLIP
RESISTANT FINISH.
4.THE SLOPE OF THE RAMP SHALL NOT EXCEED A 12:1 RATIO.
5.THE DETECTABLE WARNING DEVICE OF THE CURB RAMP
SHALL BE RED CONTRAST AND MUST BE IN COMPLIANCE
WITH ADA REQUIREMENTS.
6.A FULL DEPTH EXPANSION JOINT SHALL BE INDSTALLED
WHERE THE CONCRETE CURB RAMP JOINS THE CURB AND
GUTTER AND THE CONCRETE CURB RAMP ABUTS EXISTING
CONCRETE SIDEWALK.
7.ALL CURB RAMPS SHALL BE THE SAME WIDTH AS THE
ADJOINING SIDEWALK OR 48" WIDE IF SIDEWALK IS LESS
THAN 48" WIDE.
8.COORDINATE THE CURB RAMP AND PEDESTRIAN
CROSSWALK MARKINGS SO A 4' X 4' CLEAR SPACE AT THE
BASE OF THE CURB RAMP WILL FALL COMPLETELY WITHIN
THE PEDESTRIAN CROSSWALK LINES.
SCALE: NTSFLARED HC ACCESSIBLE RAMP6
SCALE: NTSNON-FLARED HC ACCESSIBLE RAMP7
SCALE: NTSHANDICAP PARKING SIGN HEIGHT8
SCALE: NTSTURN DOWN CURB9
SCALE: NTSTYPICAL AND HC PARKING12
SCALE: NTSSIDEWALK10
SCALE: NTSHANDICAP PARKING SIGN11SCALE: NTSCURB AND GUTTER13
SCALE: NTSCURB RAMP NOTES14
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
SCALE: NTSTEMPORARY CONSTRUCTION ENTRANCE1
12'-
0
"
MIN
.
6"
PUB
L
I
C
R
O
A
D
2"-3" COARSE
AGGREGATE OR
#4 STONE
50'
M
I
N
L
E
N
G
T
H
M
A
Y
B
E
M
O
D
I
F
I
E
D
T
O
A
C
C
O
M
M
O
D
A
T
E
B
U
I
L
D
I
N
G
P
A
D
W
I
T
H
A
P
P
R
O
V
A
L
B
Y
N
E
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
E
N
G
I
N
E
E
R
I
N
G
D
E
P
T
.
SCALE: NTSTEMPORARY ROCK CHECK DAM3
BOTTOM STRAND MIN. #14 GUAGE
TOP STRAND MIN. #14 GUAGE
8' MAX. STD. STRENGTH FABRIC W/ WIRE FENCE
MI
N
.
2
'
-
0
"
GROUND LINE
2'
-
0
"
STEEL POST
FILL
S
L
O
P
E
MA
X
.
2
'
-
0
"
STAY AND LINE WIRES MIN. #14 GUAGE
MI
N
.
2
'
-
0
"
4" X 8" TRENCH LINED W/ 12" OF
FABRIC AND COMPACTED FILL
ON TOP
NOTES:
1. WIRE FENCE (IF USED) SHALL BE MINUMUM 14
GAUGE WITH A MAXIMUM MESH OPENING OF
6-INCHES.
2. SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY
WEIGHT OF POLYOLEFINS OR POLYESTER, WHICH IS
CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS
CONFORMING TO THE REQUIREMENTS IN ASTM D
6461 AND ALSO SHOULD CONTAIN ULTRAVIOLET RAY
INHIBITORS AND STABILIZERS ACCORDING TO ASTM
D 4355.
3. SEE THE NC EROSION CONTROL MANUAL FOR
SPECIFICATIONS INSTALLING SEDIMENT FENCE
USING THE SLICING METHOD MACHINERY.
6' MAX. STD. STRENGTH FABRIC W/O WIRE FENCE
SCALE: NTSSILT FENCE OUTLET4
SILT FENCE
2'
MIN
1' - 6"
1' - 6"
MIN.
SILT FENCE
3' MAX.1'12
FLO
W
TOP VIEW
FRONT VIEW
NOTE
STRUCTURAL STONE SHALL BE
(CLASS "B") STONE FOR EROSION
CONTROL PURPOSES. SEDIMENT
CONTROL STONE SHALL BE NO.
5 OR NO. 57 STONE.
SEDIMENT
CONTROL
STONE
STRUCTURAL
STONE
SILT FENCE SHALL
REMAIN IN PLACE AND
BE FOLDED OVER TO
ACCOMMODATE OUTLET.
SILT FENCE
POST
SEEDING AND STABILIZATION6
TEMPORARY SEEDING
GRASS TYPE AMOUNT/
1000 S.F.TIME OF SEEDING INITIAL
RYE GRAIN 1-2 LBS.APRIL - JUNE 25 LBS. 10-10-10
BROWNTOP MILLET 1-2 LBS JUNE - AUGUST 25 LBS 10-10-10
PERMANENT SEEDING
GRASS TYPE AMOUNT/
1000 S.F.TIME OF SEEDING INITIAL
BERMUDA,
COMMON 1-2 LBS.APRIL - JUNE 25 LBS. 10-10-10
FESCUE, TALL
(KENTUCKY 31)5-7 LBS JUNE - AUGUST
FEB. - OCT.25 LBS 10-10-10
SERICEA
LESPEDEZA
(SLOPES
1-2 LBS MARCH - APRIL 25 LBS 10-10-10
NOTE (G.S. 113A-57 (2))
THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER T
HAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER OR OTHER
ADEQUATE EROSION CONTROL DEVICES OR STRUCTURES. IN ANY EVENT,
SLOPES LEFT EXPOSED WILL, WITHIN 21 CALENDAR DAYS OF COMPLETION
OF ANY GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH
TEMPORARY OR PERMANENT GROUND COVER, DEVICES, OR STRUCTURES
SUFFICIENT TO RESTRAIN EROSION.
GROUND STABILIZATION CRITERIA
SITE AREA DESCRIPTION STABILIZATION TIMEFRAME STABILIZATION TIMEFRAME EXCEPTIONS
PERIMETER DIKES, SWALES, DITCHES
AND SLOPES 7 DAYS NONE
HIGH QUALITY WATER ZONES 7 DAYS NONE
SLOPES STEEPER THAN 3:1 7 DAYS IF SLOPES ARE 10 FT OR LESS IN IN LENGTH AND ARE
NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED
SLOPES 3:1 TO 4:1 14 DAYS
- 7 DAYS FOR SLOPES GREATER THAN 50 FT IN LENGTH
AND WITH SLOPES STEEPER THAN 4:1
- 7 DAYS FOR PERIMETER DIKES, SWALES, DITCHES,
PERIMETER SLOPES AND HQW ZONES
- 10 DAYS FOR FALLS LAKE WATERSHED
AREAS WITH SLOPES FLATTER THAN
4:1 14 DAYS
- 7 DAYS FOR PERIMETER DIKES, SWALES, DITCHES,
PERIMETER SLOPES AND HQW ZONES
- 10 DAYS FOR FALLS LAKE WATERSHED UNLESS THERE
IS ZERO SLOPE
SCALE: NTSTEMPORARY DIVERSION DITCH8
SIDE SLOPES
2:1 SLOPE (MAX)
POSITIVE GRADE 1.0% MAX.UPSLOPE TOE
PLAN VIEW
CROSS SECTION
18"GRADE
WIDTH
2' MIN2:1 MAX
#57 STONE CHECK DAM
6" TOP WIDTH, 12" TALL
SIDE SLOPES 2:1
- STABILIZE DIVERSION DITCH WITH
TEMPORARY SEEDING AND EROSION
CONTROL NETTING
2' MIN
COMPACTED
SEDIMENT LADEN
WATER FLOW
#57 STONE CHECK DAM
6" TOP WIDTH, 12" TALL
SIDE SLOPES 2:1
SCALE: NTSWATTLES5
NOTES:
1. USE MINIMUM 18" DIA. EXCELSIOR WATTLE.
2. USE 2"x2" WOODEN STAKES 2-FT IN LENGTH ON THE UPSLOPE AND
DOWNSLOPE
AT AN ANGLE TO WEDGE THE WATTLE TO THE BOTTOM OF THE SWALE.
3. STAPLE EVERY 1 LF ON BOTH SIDES OF THE WATTLE TO SECURE IT TO THE
BOTTOM OF THE SWALE.
2' UPSLOPE &
DOWNSLOPE STAKES, TYP.
SECURE WATTLE
WITH UPSLOPE AND
DOWNSLOPE STAKES
AND STAPLES.
MIN. 10 LF EXCELSIOR MATTING
2' MIN. ON UPSLOPE
AND 8' MIN. ON DOWNSLOPE
OUTLET BARREL
(SEE PLANS FOR
MATERIAL)
BAFFLES (3)
INLET ZONE:
25%
FIRST
CELL: 25%
SECOND
CELL: 25%
OUTLET
ZONE: 25%
6" MIN INVERT ELEVATION
SKIMMER
(SEE DETAIL)
3:1 SLOPES
CMP RISER
STAKE - WITH MARKER AT
SEDIMENT CLEAN OUT
DEPTH
WATER
LEVEL
DURING
STORM
TOP OF DAM
(8' MIN WIDTH)
EMERGENCY
SPILLWAY
SEDIMENT
STORAGE
NOTES
1.BAFFLE MATERIAL SHALL BE MATERIALS SUCH AS 700 G/M
COIR EROSION BLANKET, COIR MESH, OR TREE PROTECTION
FENCE FOLDED OVER TO REDUCE PORE SIZE.
2.THE BAFFLE MATERIAL NEEDS TO BE SECURED AT THE
BOTTOM AND SIDES USING STAPLES OR BY TRENCHING AS
FOR SILT FENCE.
NOTES (CONT'D)
3.LOCATE THE EMERGENCY SPILLWAY ON NATURAL SOILS.
AVOID PLACING IT THROUGH FILL MATERIAL WHEREVER
POSSIBLE.
4.ALL RUNOFF MUST DISCHARGE TO THE INLET SIDE OF THE
BASIN. DISCHARGE RUNOFF INTO THE BASIN IN A MANNER
THAT MINIMIZES EROSION.
3:1 SLOPES
CONCRETE BASE
EARTH DAM
SCALE: NTSSKIMMER SEDIMENT BASIN9
CE501
EROSION CONTROL
DETAILS
NOTES:
1. DRIVE 5-FOOT STEEL POSTS (1.25 lb/lf steel) 2 FEET INTO THE GROUND SURROUNDING THE INLET.
SPACE POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET APART.
2. SURROUND THE POSTS WITH AT LEAST 19-GAUGE HARDWARE CLOTH WITH A 1/4-INCH MESH
OPENING. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE, AND BOTTOM FOR
A MIN. 2 FEET ABOVE THE GROUND. PLACING A 2-FOOT FLAP OF THE WIRE MESH UNDER THE
GRAVEL FOR ANCHORING AND REMOVAL IS RECOMMENDED.
3. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. THE TOP ELEVATION OF
THE STRUCTURE MUST BE AT LEAST 12-INCHES LOWER THAN THE SURROUNDING GROUND
ELEVATION DOWNSLOPE FROM THE INLET TO ENSURE THAT STORM FLOWS GET INTO THE
INTENDED INLET; UNLESS OTHER SEDIMENT-CONTROL DEVICES ARE INSTALLED TO PREVENT
OFF-SITE SEDIMENT-RUNOFF.
STEEL POSTS 2 FT IN
GROUND.
19-GAUGE & 0.25" MESH
OPENING HARDWARE
CLOTH EXTENDS MIN. 2
FT ABOVE GROUND.
NCDOT #5 OR #57 WASHED STONE
PLACED TO A HEIGHT OF 16"
MINIMUM ABOVE TOP OF BOX
@ 2:1 SLOPE.
RIPRAP
LOCATIONS RIP-RAP APRON SCHEDULE
TSB-1
TSB-2
RRP-1
FIRE ACCESS
FAA-1
FAA-2
A A
PLAN
NO WELL-DEFINED CHANNEL
3d d
La
t
oo
NON-WOVEN
FILTER FABRIC
NCDOT CLASS B (d50=8")
EROSION CONTROL STONE
ON A LAYER OF 4" NCDOT
#5 OR #57 STONESECTION
NOTES:
1.BUILD RIDGE HIGHER THAN DESIGN AND COMPACT WITH WHEELS OF
CONSTRUCTION EQUIPMENT. COMPACTED RIDGE MUST BE AT OR
ABOVE DESIGN GRADE AT ALL POINTS.
2.LEAVE SUFFICIENT AREA TO PERMIT CLEAN OUT AND REGRADING.
3.CONSTRUCT SILT FENCE ON DOWNSTREAM SIDE OF BERM.
TEMP.
EARTHEN
BERM
2' MIN. TOP AREA
10%
T.O.B.
EXISTING
DITCH
3:1
M
A
X
I
M
U
M
3
:
1
M
A
X
I
M
U
M
SETTLEMENT
2' ABOVE
SILT FENCE
SCALE: NTSTEMPORAY INLET PROTECTION7SCALE: NTSTEMPORARY DITCH PLUG10SCALE: NTSRIPRAP OUTLET PROTECTION11
SCALE: NTSTEMPORARY SILT FENCE2
2:1 S
L
O
P
E
2:1
S
L
O
P
E
MATCH
1.5'
2'
NCDOT CLASS B
EROSION
CONTROL STONE
(d50=8")
SEDIMENT R
U
N
O
F
F
FROM DITCH
NON-WOVEN
FILTER FABRIC
12" MIN. THICK
OF NCDOT #5 OR
#57 WASHED STONE
1.5'
SEDIMENT
STORAGE
6" WEIR
6" WEIR
CROSS SECTION WITH A WEIR
4'
TOP OF
DITCH
LONGITUDINAL
SECTION
MAINTENANCE NOTES:
·INSPECT CHECK DAMS AND CHANNELS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1
2 INCH OR
GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. CLEAN OUT SEDIMENT, STRAW, LIMBS, OR OTHER
DEBRIS THAT COULD CLOG THE CHANNEL WHEN NEEDED.
·ANTICIPATE SUBMERGENCE AND DEPOSITION ABOVE THE CHECK DAM AND EROSION FROM HIGH FLOWS
AROUND THE EDGES OF THE DAM. CORRECT ALL DAMAGE IMMEDIATELY. IF SIGNIFICANT EROSION
OCCURS BETWEEN DAMS, ADDITIONAL MEASURES CAN BE TAKEN SUCH AS, INSTALLING A PROTECTIVE
RIPRAP LINER IN THAT PORTION OF THE CHANNEL.
·REMOVE SEDIMENT ACCUMULATED BEHIND THE DAMS AS NEEDED TO PREVENT DAMAGE TO CHANNEL
VEGETATION, ALLOW THE CHANNEL TO DRAIN THROUGH THE STONE CHECK DAM, AND PREVENT LARGE
FLOWS FROM CARRYING SEDIMENT OVER THE DAM. ADD STONES TO DAMS AS NEEDED TO MAINTAIN
DESIGN HEIGHT AND CROSS SECTION.
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
SCALE: NTSNCG01 GROUND STABLIZATION AND MATERIALS HANDLING2
SCALE: NTSNCG01 SELF-INSPECTION RECORDKEEPING AND REPORTING1 CE502
EROSION CONTROL
DETAILS
STEEL POST
FRONT VIEW
SIDE VIEW
40"
WARNING SIGN DETAIL
18"
VARIABLE AS DIRECTED BY THE ENGINEER
8' MAX.
GRADE
TREE PROTECTION AREA
DO NOT ENTER
ORANGE, UV RESISTANT
HIGH - TENSILE STRENGTH
POLY BARRICADE FABRIC (TYPICAL)
ORANGE, UV RESISTANT
HIGH - TENSILE STRENGTH
POLY BARRICADE FABRIC (TYPICAL)
WARNING SIGN
PLASTIC OR
WIRE TIES
NOTES:
1. THE TREE PROTECTION FENCING SHALL NOT BE VIOLATED FOR THE ENTIRE DURATION OF THE PROJECT WITHOUT APPROVAL
FROM URBAN FORESTRY STAFF.
2. WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL. LETTERS TO BE 3" HIGH, MINIMUM, CLEARLY LEGIBLE
AND SPACED AS DETAILED.
3. SIGNS SHALL BE PLACED AT 50' MAXIMUM INTERVALS. PLACE A SIGN AT EACH END OF LINEAR TREE PROTECTION AND 50' ON
CENTER THEREAFTER. FOR TREE PROTECTION AREAS LESS THAN 100' IN PERIMETER, PROVIDE NO LESS THAN TWO SIGNS PER
PROTECTION AREA.
4. ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. MAINTAIN TREE PROTECTION FENCE AND SIGNS THROUGHOUT
DURATION OF PROJECT.
5. TREE PROTECTION FENCING AND SIGNAGE SHALL BE REMOVED AFTER CONSTRUCTION.
6. ADDITIONAL SIGNS MAY BE REQUIRED NCDEQ AND BRUNSWICK COUNTY, BASED ON ACTUAL FIELD CONDITIONS.
WARNING SIGN
ZONA PROTECTORA PARA
LOS ARBOLES
PROHIBIDO ENTRAR
TREE PROTECTION AREA
DO NOT ENTER
ZONA PROTECTORA PARA
LOS ARBOLES
PROHIBIDO ENTRAR
NOTE:
THE CRITICAL ROOT ZONE (CRZ) OF A TREE IS
WHERE THE MAJORITY OF A TREE'S ROOTS LAY.
85% OF MOST TREE ROOTS ARE FOUND IN THE TOP
24" OF THE SOIL AND SUPPLY THE MAJORITY OF
NUTRIENTS AND WATER. GENERALLY, ROOTS
SPREAD OUT 2-3X THE HEIGHT OF THE TREE.
ORANGE SAFETY FENCE
OR ORANGE SILT FENCE
(TYPICAL)
CRZ
NOTES:
1. PROTECT CRITICAL ROOT ZONE (CRZ) OF TREES PRIOR TO CONSTRUCTION. CLEARLY MARK THE TREES
AND ERECT A PROTECTIVE BARRIER AT THE CRZ. BARRIER SHALL BE MAINTAINED UNTIL CONSTRUCTION
IS COMPLETE.
2.CRZ RADIUS IS 1 FT PER INCH OF TREE DIAMETER AT BREAST HEIGHT (DBH).
3.IF CONSTRUCTION OCCURS WITHIN THE CRZ, AT LEAST 12" OF MULCH AND/OR LOGGING MATTS SHALL
BE PLACED WHERE MACHINERY MANEUVERS TO REDUCE SOIL COMPACTION IN THIS ZONE.
4.WHERE SIDEWALKS AND PATHWAYS PASS WITHIN CRZ, EXTRA CARE SHALL BE TAKEN TO AVOID
DAMAGE TO THE ROOTS. ALTERNATE CONSTRUCTION METHODS, SUCH AS A REINFORCED SIDEWALK,
SHALL BE IMPLEMENTED AS NECESSARY.
5. FOR ALL TREES, CUTTING OF LARGE STRUCTURAL ROOTS LOCATED NEAR THE BASE OF THE TRUNK IS
PROHIBITED. DO NOT COMPACT SOIL BENEATH TREES. NO VEHICLE SHALL BE ALLOWED TO PARK
UNDER TREES. NO MATERIALS OR EQUIPMENT SHALL BE STORED BENEATH TREES. DAMAGING THE
BARK WITH LAWNMOWERS, CONSTRUCTION EQUIPMENT, OR ANYTHING ELSE IS PROHIBITED.
CONTRACTOR SHALL REPAIR DAMAGE TO TREES.
6. FAILING TO INSTALL OR MAINTAIN PROTECTION MEASURES SHALL RESULT IN A STOP WORK ORDER AND
FINE OF $500/DAY. DISTURBANCE OTHER THAN THAT ALLOWED ON THE APPROVED PLAN WILL REQUIRE
OWNER TO POST A LETTER OF CREDIT FOR 3 YRS FOR TREE MITIGATION.
3' MIN
DBH
NOTE:
CROWN OF THE TREE IS NEEDED FOR LEAF
GROWTH TO PRODUCE OXYGEN, FILTER
THE AIR, REDUCE WIND AND SOFTEN NOISE.
DO NOT DISFIGURE CROWN WITH
INTENSIVE PRUNING.
8' MAX
SCALE: NTSTREE PROTECTION SIGNAGE4SCALE: NTSTREE PROTECTION FENCING5
SCALE: NTSFAIRCLOTH SKIMMER6
SCALE: NTSSILT SACK DETAIL7 SCALE: NTSROLLED EROSION CONTROL PRODUCT3
NOTES:
1. USE EXCELSIOR (WOOD-FIBER) MATTING AS THE ROLLED EROSION CONTROL PRODUCT ON SLOPES AND BOTTOMS OF
DRAINAGE DITCHES AS SPECIFIED ON 1/CE502.
2. STABILIZE WITH PERMANENT VEGETATION WHEN CONDITIONS ARE SUITABLE FOR ROOT ESTABLISHMENT.
NOTE:
SILT CONTROL SYSTEM TO BE USED IN CONJUNCTION WITH PUMP AROUND
IF DEEMED NECESSARY BY SEDIMENT CONTROL INSPECTOR TO TREAT ANY
SEDIMENT-LADEN WATER WITHIN THE DRY WORK AREA.
DEWATERING/FILTER BAG MATERIALS SPECIFICATIONS:
THE DEWATERING/FILTER BAG SHALL BE MADE OF NON-WOVEN
GEOTEXTILE WITH A MINIMUM SURFACE AREA OF 225 SQUARE FEET PER
SIDE. ALL STRUCTURAL SEAMS SHALL BE SEWN WITH A DOUBLE STITCH
USING A DOUBLE NEEDLE MACHINE WITH HIGH STRENGTH THREAD. THE
SEAM STRENGTH SHALL WITHSTAND 100LB/IN USING ASTM D-4884 TEST
METHOD. THE DEWATERING/FILTER BAG SHALL HAVE A NOZZLE LARGE
ENOUGH TO ACCOMMODATE A FOUR INCH DISCHARGE HOSE. THE NOZZLE
SHALL BE SEALED TIGHTLY AROUND THE DISCHARGE HOSE WITH A STRAP
OR SIMILAR DEVICE TO PREVENT UNTREATED WATER FROM ESCAPING.
THE GEOTEXTILE FABRIC SHALL BE A NON-WOVEN FABRIC WITH THE
FOLLOWING PROPERTIES:
WEIGHT ASTM D-3776 10 OZ/YD
GRAB TENSILE ASTM D-4632 270 LBS
PUNCTURE ASTM D-4833 150 LBS
FLOW RATE ASTM D-4491 70 GAL/MIN/SQ FT
PERMITIVITY ASTM D-4991 1/1.3 SEC
UV RESISTANCE ASTM D-4355 70%
AOS % RETAINED ASTM D-4751 100
CONSTRUCTION:
THE DEWATERING/FILTER BAG SHALL BE INSTALLED OVER A 3 INCH
GRAVEL BASE OR A STRAW BALE BASE TO PROMOTE INFILTRATION AND
DEWATERING OF THE FILTER BAG.
TOP VIEW
SIDE VIEW
15.0'
15.0'
PUMP INTO SDSP OR
THROUGH AN APPROVED
DEWATERING DEVICE
WORK AREA
EARTHEN COFFER DAM
EARTHEN COFFER DAM
FLOW
Section A-A
BASE FLOW + 1 FOOT
(2 FOOT MINIMUM)
CROSS SECTION OF
SANDBAG DIKE
INTAKE HOSE
DEWATERING PUMP
PLAN VIEW
P
DISCHARGE
HOSE
A
FLOW
A
IMPLEMENTATION SEQUENCE:
SEDIMENT CONTROL MEASURES, PUMP-AROUND PRACTICES, AND
ASSOCIATED DREDGE CONSTRUCTION SHOULD BE COMPLETED IN THE
FOLLOWING SEQUENCE (REFER TO DETAIL).
1. THE CONTRACTOR SHOULD ONLY BEGIN WORK IN AN AREA WHICH CAN
BE COMPLETED BY THE END OF THE DAY. AT THE END OF EACH WORK
DAY, THE WORK AREA MUST BE STABILIZED AND THE PUMP AROUND
REMOVED. WORK SHOULD NOT BE CONDUCTED DURING RAIN EVENTS.
2. EARTHEN COFFER DAM SHOULD BE SITUATED AT THE ENDS OF THE
WORK AREA AS SHOWN ON THE PLANS.
3. WATER FROM THE WORK AREA SHOULD BE PUMPED TO A SEDIMENT
FILTERING MEASURE SUCH AS A DEWATERING BASIN, SEDIMENT BAG,
OR OTHER APPROVED SOURCE. THE MEASURE SHOULD BE LOCATED
SUCH THAT THE WATER DRAINS DOWNSTREAM OF THE WORK AREA.
SCALE: NTSPUMP AROUND DETAIL8
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
SCALE: NTSCONCRETE DROP INLET1 CG501
GRADING AND
DRAINAGE DETAILS
NOTE:
FINISHED GRADE
1.INJECTION MOLDED FITTING ARE
AVAILABLE IN TEES, WYES,
REDUCERS, 45° BENDS AND
BELL/BELL COUPLERS.
2.WATERTIGHT (WT) JOINTS
SHOWN. SOIL-TIGHT (ST) FITTINGS
ARE ALSO AVAILABLE.
RAIN LEADER
BOOT WITH BUILT
IN CLEANOUT, SEE
ARCHITECTURAL
DRAWINGS
BUILDING
FACE
INSERT INJECTION MOLDED,
GASKETED SPIGOT BY BELL
REDUCER
INJECTION
MOLDED WT
90° BEND
INJECTION
MOLDED WT
TEE
SEE STORM
DRAINAGE PLANS
FOR PIPE SIZE
*INJECTION MOLDED ST 45°
WYE
CLEAN OUT END CAP
SNAP CONNECTION
SCALE: NTSDROP INLET FRAME AND GRATES2
SCALE: NTSANCHORAGE FOR FRAMES3
SCALE: NTSTRAFFIC BEARING PRECASST DRAINAGE STRUCTURE4
SCALE: NTSPRECAST MANHOLE DIAMETER5
SCALE: NTSMANHOLE FRAME AND COVER6
SCALE: NTSDRAINAGE STRUCTURE STEPS7
SCALE: NTSROOF LEADER8
SCALE: NTSDROP INLET CONCRETE COLLAR FOR DROP INLETS IN ASPHALT5
2.
0
0
'
2.
0
0
'
2.00'2.00'
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
CG502
GRADING AND
DRAINAGE DETAILS
SCALE: NTSDURASLOT VARIABLE SLOT RISER1
2DURASLOT VARIABLE ASSEMBLY2
SCALE: NTSDURASLOT ENDCAPS3
SCALE: NTSDURASLOT ADAPTERS4
SCALE: NTSDURASLOT VARIABLE COUPLERS5
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
SCALE: NTSCOW PAVEMENT REPAIRS - UTILITY CUTS1 CU501
UTILITY DETAILS
SCALE: NTSCOW TYPICAL ROAD REBUILD2
SCALE: NTSNCDOT PAVEMENT REPAIRS3
SCALE: NTSPIPE EMBEDMENT TYPES4SCALE: NTSTAPPING SLEEVE AND VALVE ASSEMBLY7SCALE: NTSSTANDARD NOTES10
SCALE: NTSVALVE DETAIL5
SCALE: NTSTRACER WIRE DETAIL6
SCALE: NTSSTRUCTURAL BRIDGING OVER WATER & SEWER8
SCALE: NTSTHRUST BLOCK9
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
CU502
UTILITY DETAILS
SCALE: NTSSEWER SERVICE CONNECTION (<8' DEEP)1
SCALE: NTSFORCE MAIN CONNECTION - PRIVATE TO PUBLIC2
SCALE: NTSSEWER SERVICE CONNECTION (>8' DEEP)3
SCALE: NTSE-ONE QUADPLEX FIBERGLASS PUMP STATION4SCALE: NTSMANHOLE RIM ADJUSTMENTS7
SCALE: NTSE-ONE POWER PANEL5
SCALE: NTSSEWER SERVICE TYPICAL CLEAN-OUT6
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
CU503
UTILITY DETAILS
SCALE: NTSCOMMERICAL WATER SERVICE METERS1
SCALE: NTSCOMMERICAL WATER SERVICE METERS2
SCALE: NTSDOUBLE WATER SERVICE3
SCALE: NTS2 INCH BLOW-OFF4SCALE: NTSFIRE MAIN CONNECTION7SCALE: NTSFIRE SERVICE REDUCED PRESSURE DETECTOR10
SCALE: NTSSAMPLING STATION5
SCALE: NTSFIRE HYDRANT ASSEMBLY6
SCALE: NTSREDUCED PRESSURE PRINCIPLE ASSEMBLY8
SCALE: NTSDOUBLE CHECK VALVE ASSEMBLY9
EQUAL TO THE
PLANT SPACING
AS SPECIFIED
(TYP.)
GENERAL NOTES:
A.SCARIFY BOTTOM AND SIDES OF PLANTING PIT.
B.THE BOTTOM OF SHRUB ROOT BALLS SHALL NOT PROJECT INTO THE NATIVE SUBGRADE .
LARGER PLANTS WILL REQUIRE ADDITIONAL TOPSOIL DEPTH.
C.BACKFILL PLANTING PITS WITH TOPSOIL MIXTURE AS SPECIFIED, INSTALL IN 6" LAYERS, HAND
TAMP TO REMOVE VOIDS AND WATER EACH LAYER
D.ALL ROOT BALLS REMOVED FROM CONTAINERS SHALL BE SCARIFIED BY HAND PRIOR TO
PLACEMENT AND BACKFILLING WITH PREPARED SOILS. HAND TOOLS SHALL NOT BE USED TO
SCARIFY ROOT BALLS.
6"
M
I
N
.
FO
R
M
M
O
U
N
D
E
D
B
E
D
WI
T
H
N
A
T
I
V
E
T
I
L
L
E
D
S
O
I
L
PR
I
O
R
T
O
P
L
A
N
T
I
N
G
PLANT SPACING
AS SPECIFIED
(TYP.)
PLANT SPACING CHART
SPACING (A)ROW OFFSET (B)
1'-0" O.C.10" O.C.
1'-6" O.C.1'-4" O.C.
2'-0" O.C.1'-9" O.C.
2'-6" O.C.2'-2" O.C.
3'-0" O.C.2'-7" O.C.
3'-6" O.C.3'-0" O.C.
4'-0" O.C.3'-6" O.C.
SPACING (A)ROW OFFSET (B)
5'-0" O.C.4'-4" O.C.
6'-0" O.C.5'-2" O.C.
7'-0" O.C.6'-1" O.C.
8'-0" O.C.6'-11" O.C.
9'-0" O.C.7'-10" O.C.
10'-0" O.C.8'-8" O.C.
A
B
PLANT SPACING
PLAN
A
TOPSOIL PER
SPECIFICATIONS
SHRUB AS SPECIFIED
PER LANDSCAPE PLAN(S)
NATIVE SUBGRADE
ADJACENT TURF AREA,
REFER TO PLANTING
PLAN FOR LOCATIONS
NATIVE SOIL, TILL SOIL
TO A 6" MIN. DEPTH
MULCH AS SPECIFIED,
KEEP 4" AWAY FROM
ROOT CROWN
ROOT CROWN TO BE SET
2" ABOVE EXISTING
GRADE MIN.
4" DEEP SHOVEL DUG "V"
TRENCH, SEE
LANDSCAPE PLAN FOR
LOCATIONS
SHRUB ROOT BALL
PLANTING BED
EDGE
SHRUB
SECTION
1"
M
I
N
.
6" MIN.
TREES COMMON NAME SIZE CALIPER HEIGHT QTY
ACER BUERGERIANUM TRIDENT MAPLE B & B 2.5" CAL.12C-14C HT.5 SINGLE DOMINANT LEADER, UNIFORM
CANOPY & MATCHED
MAGNOLIA GRANDIFLORA CLITTLE GEMC DWARF SOUTHERN MAGNOLIA B & B 2" CAL.8C-10C HT.3 SINGLE DOMINANT LEADER, UNIFORM
CANOPY, FULL TO GROUND & MATCHED
QUERCUS VIRGINIANA SOUTHERN LIVE OAK B & B 5" CAL.12C-14C HT.3 SINGLE DOMINANT LEADER, UNIFORM
CANOPY & MATCHED
SHRUBS COMMON NAME SIZE HEIGHT SPREAD SPACING QTY REMARKS
ABELIA X GRANDIFLORA CKALEIDOSCOPEC GLOSSY ABELIA 3 GAL.18"-24" HT.18"-24" SPD.4C O.C.57 UNIFORM HEAD & MATCH
AZALEA ENCORE ENCORE AZALEA 3 GAL.18"-24" HT.18"-24" SPD.4C O.C.52 UNIFORM HEAD & MATCHED
GARDENIA JASMINOIDES CFROSTPROOFC FROSTPROOF GARDENIA 3 GAL.15"-18" HT.18"-24" SPD.4C O.C.159 UNIFORM HEAD & MATCH
ILEX CORNUTA CDWARF BURFORDC DWARF BURFORD HOLLY 3 GAL.24"-30" HT.24"-30" SPD.4C O.C.167 UNIFORM HEAD & MATCHED
ITEA VIRGINICA CHENRYCS GARNETC HENRYCS GARNET SWEETSPIRE 3 GAL.18"-24" HT.18"-24" SPD.6C O.C.70 UNIFORM HEAD & MATCHED
MUHLENBERGIA CAPILLARIS PINK MUHLY GRASS 3 GAL.18"-24" HT.24"-30" SPD.3C O.C.427 UNIFORM HEAD & MATCH
OSMANTHUS X FORTUNEI SWEET OLIVE 7 GAL.24"-30" HT.24"-30" SPD.8C O.C.5 UNIFORM HEAD & MATCHED
PANICUM VIRGATUM 'SHENANDOAH'SHENANDOAH SWITCH GRASS 7 GAL.24"-30" HT.24"-30" SPD.4C O.C.140 UNIFORM HEAD & MATCH
PLANT SCHEDULE
STAKING
PLAN
2 TO 3 TIMES THE
ROOT BALL DIAMETER
6"
GENERAL NOTES:
A.TREE TO BE STRAIGHTENED PRIOR TO BACKFILL AND GUYING
B.SCARIFY BOTTOM AND SIDES OF PLANT PIT.
C.STAKE AND GUY TREES 3" CALIPER OR GREATER, OR TREES IN WINDING
LOCATIONS AS DIRECTED BY LANDSCAPE ARCHITECT.
D.DO NOT WRAP TREE TRUNK.
E.MARK NORTH SIDE OF TREE AT NURSERY AND PLANT WITH MARKING FACING
NORTH.
F.BACKFILL PLANTING PITS WITH TOPSOIL MIXTURE AS SPECIFIED, PACK SOIL
AROUND BASE OF ROOTBALL TO STABILIZE, INSTALL REMAINDER IN 9" LAYERS,
HAND TAMP TO REMOVE VOIDS AND WATER EACH LAYER
2"4"
120°
4" DEEP SHOVEL
DUG "V" TRENCH,
SEE LANDSCAPE
PLAN FOR
LOCATIONS
"ARBORTIE" HEAVY DUTY
TREE GUY STRAPPING,
COLOR TO BE GREEN, 900LB
BREAK STRENGTH, SLACK
STRAP LIGHTLY TO ALLOW
SLIGHT MOVEMENT IN TREE
NATIVE SUBGRADE
TREE AS SPECIFIED PER
LANDSCAPE PLAN(S)
MULCH AS SPECIFIED,
KEEP 6" AWAY FROM
TREE TRUNK
LOOP STRAPPING JUST
ABOVE FIRST LIMB AND
AROUND CENTRAL
LEADER, REFER TO
MANUFACTURER'S
RECOMMENDATION FOR
TYING METHOD
PULL BACK TOP 14 OF
BURLAP, TWINE TIES AND
WIRE BASKET, LEAVE
REMAINDER AROUND
ROOT BALL
FINISH GRADE
2" X 2" X 30" UNTREATED
LUMBER STAKES (TYP.), (3)
TOTAL EQUALLY SPACED
AROUND TREE, INSTALL
OUTSIDE OF ROOTBALL
AND BACKFILLED SOIL
MIXTUREBALLED AND BURLAP
ROOT BALL
TOPSOIL
ROOT FLARE TO BE SET
2" ABOVE EXISTING
GRADE
PREVAILING
WINDS
STAKE
TRUNK
COMPACTED NATIVE
SOIL PEDESTAL
SECTION
NATIVE SOIL, TILL SOIL
TO A 6" MIN. DEPTH
TH
E
L
I
N
E
S
H
O
W
N
A
B
O
V
E
I
S
E
X
A
C
T
L
Y
ON
E
I
N
C
H
L
O
N
G
A
T
T
H
I
S
S
H
E
E
T
S
OR
I
G
I
N
A
L
P
A
G
E
S
I
Z
E
LS
3
P
P
R
O
J
E
C
T
:
ORIG
SUBMISSION:
NO
T
F
O
R
CO
N
S
T
R
U
C
T
I
O
N
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
COPYRIGHT 2021 ALL RIGHTS RESERVED. PRINTED OR
ELECTRONIC DRAWINGS AND DOCUMENTATION MAY
NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION FROM LS3P ASSOCIATES LTD.
3/
2
1
/
2
0
2
2
8
:
4
8
:
5
8
A
M
11
0
9
-
2
1
0
9
6
5
2022/07/27
Evans General
Contractors
Ga
r
d
n
e
r
D
r
i
v
e
Wi
l
m
i
n
g
t
o
n
,
N
C
2
8
4
0
5
CI
L
-
I
L
M
C
O
L
D
S
T
O
R
A
G
E
PERMIT DRAWINGS
243 North Front Street
Wilmington, North Carolina 28403
NC License # F-1222
PROJECT: 08879-0003
CL501
LANDSCAPE DETAILS
SCALE: NTSPLANTING SCHEDULE1