Loading...
241 Buff CircleSHEET NO. 0.00 DRAWN BY DRAFT. MGR. REVISIONS CA S T L E H A Y N E , N C DATE THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2018 CI T Y : DATE:07/16/2019 ZI P : ST R E E T : 28 4 2 9 LA Y O U T : JOB NUMBER: REV REV #1 REV #2 REV #3 REV #4 BU I L D E R S B L I T Z PR O J E C T : CO V E R S H E E T ( ) MO D E L : IR I S ( ) SE R I E S : HA B I T A T OPS. MGR. BONUS ROOM AB: Anchor Bolt ABV: Above AC: Air Conditioning ACC: Access ACOUST: Acoustical ADH: Adhesive ADJ: Adjust AF: Arch Fault AFF: Above Finished Floor AGG: Aggregate ALM: Alarm ALT: Alternate ALUM: Aluminum AMT: Amount ANCH: Anchor AP: Access Panel APPROX: Approximate ASPH: Asphalt AVG: Average -It is the contractor’s responsibility to verify all details and dimensions -All work shall be performed in accordance with all applicable national, state, and local codes and regulations. -All dimensions are to rough frame of studs or to the outside of masonry. -Final cabinet layout will be designed by cabinet supplier. -All footings to be below frost line and must rest on undisturbed soil capable of handling the building. -All penetrations are to be sealed in accordance with state and local codes. -Insulate all Plumbing on exterior walls. SYMBOL LEGEND "FINISHED SQUARE FOOTAGE CALCULATIONS FOR THIS HOUSE WERE MADE BASED ON PLAN DIMENSIONS AND MAY VARY FROM THE FINISHED SQUARE FOOTAGE OF THE HOUSE AS BUILT." IRIS BTW: Between BKR: Breaker BLDG: Building BLK: Block BLKG: Blocking BLT-IN: Built-In BM: Beam BOT: Bottom BRG: Bearing BRK: Brick BRKT: Bracket BRZ: Bronze BSMT: Basement SQ.FT. 1st. FLOOR H.B. SQ.FT. Architectural Cover Sheet 1.01 1.02 1.03 1.04 2.01 3.01 4.01 5.01 Front Elevation Left Side Elevation Right Side Elevation Rear Elevation First Floor Plan Foundation Plan Roof Plan First Floor Electrical Plan TABLE OF CONTENTS P. LAM: Plastic Laminate PAR: Parallel PROJECT SQUARE FOOTAGE 6 12 6/12 C/C: Center to Center CAB: Cabinet CAP: Capacity CAV: Cavity CER: Ceramic C.I.: Cast Iron CIR: Circle CJ: Control Joint CLG: Ceiling ABBREVIATIONS HB: Hose Bib HDR: Header HGT: Height HM: Hollow Metal HORIZ: Horizontal HW: Hot Water CLG JT: Ceiling Joist CLO: Closet CLR: Clear CMU: Concrete Masonry Unit C.O.: Cased Opening COL: Column CONC: Concrete CPR: Copper CPT: Carpet CRS: Course CTR: Center EA: Each EJ: Expansion Joint ELEC: Electrical ENCL: Enclosure ENG: Engineer EQ: Equal EXH: Exhaust EXIST: Existing DBL: Double DEG: Degree DEMO: Demolition DEPT: Department DH: Double Hung DIAG: Diagonal DIA: Diameter DIFF: Diffuser DIM: Dimension DISL: Disposal DN: Down DTL: Detail CW: Dish Washer DWG: Drawing F TO F: Face to Face FA: Fire Alarm FAST: Fastener, Fasten FB: Floor Break FD: Floor drain FDN: Foundation GA: Gauge, Gage GALV: Galvanized GC: General Contractor GEN: General GFI: Ground Fault Interrupted GL: Glass GL BLK: Glass Block GLZ: Glaze GRND: Ground GT: Grout GYP: Gypsum GYP BD: Gypsum Board IN: Inch INSUL: Insulation INT: Interior INTERM: Intermediate STD: Standard STL: Steel STOR: Storage STRT: Straight STRUC: Structural STRUCT: Structural SUR: Surface SYP: Southern Yellow Pine SYS: System NOM: Nominal NTS: Not To Scale PARTN: Partition PDS: Pull Down Stair PERIM: Perimeter PERP: Perpendicular PH: Phase PL: Plate PLAS: Plaster, Plastic PLBG: Plumbing PLTF: Platform PLYWD: Plywood PNT: Paint PORC: Porcelain PTN: Partition PWR: Power JST: Joist JT: Joint QTY: Quantity TEL: Telephone THK: Thick, Thickness THR: Threshold THRM: Thermal THRU: Through TLT: Toilet TR: Transom TRD: Tread TV: Television TYP: Typical FGL: Fiberglass FIN: Finish, finished FIXT: Fixture FLASH: Flashing FLG: Flooring FLG: Flange, FLR: Floor FLUOR: Fluorescent FP: Fireplace FRM: Frame FT: Foot FTG: Footing FUR: Furring TOTAL 1148 0 SQ.FT. SQ.FT. 0 0 SQ.FT. SQ.FT. 120 0.00 Cover Sheet GENERAL NOTES R & S: Rod and Shelf RA: Return Air RAD: Radius, Radiator RB: Rubber REBAR: Reinforcing Bar RECP: Receptacle REINF: Reinforcement REF: Refrigerator REQD: Required RF: Roof RGH: Rough RM: Room RO: Rough Opening SCH: Schedule SCR: Screen SECT: Section SF: Square Foot SHT: Sheet SHTHG: Sheathing SHLVS: Shelves SHWR: Shower SIM: Similar SQ: Square SS: Stainless Steel UNFIN: Unfinished UNO: Unless Noted Otherwise VAC: Vacuum VERT: Vertical VIN: Vinyl VLT: Vault VNR: Veneer VT: Vinyl Tile VTR: Vent Through Roof W/O: Without WD: Wood WH: Water Heater W.I.C.: Walk In Closet WIN: Window WP: Waterproof WRSTP: Weatherstripping MARB: Marble MAS: Masonry MAT: Material MAX: Maximum MFD: Manufactured MFR: Manufacture MIN: Minimum MIR: Mirror MISC: Miscellaneous MLD: Molding MO: Masonry Opening O TO O: Out to Out OC: On Center OH: Overhead OPG: Opening OPP: Opposite OUT: Outlet OVFL: Overflow KIT: Kitchen KP: Kickplate LCFP: Light Ceiling Fan Package LMS: Limestone LN: Length LNDG: Landing LNDRY: Launrdy LNTL: Lintel LT: Light LTG: Lighting LTL: Lintel LVL: Laminated Veneer Lumber 6.00 SECTION & DETAIL ROOF SLOPE SAMPLE D-5.0 KEYNOTE SHOWER HEAD PERSPECTIVE REPRESENTATION FLOOR BREAK F.B. HOSE BIB Rendering may not match elevations or plans and is strictly a representation of a 3D model. 55 GARAGE SQ.FT.0 2nd. FLOOR SQ.FT. SQ.FT. 0 UNFINISHED BASEMENT FRONT PORCH BACK PORCH 1148 PATIO Sections & Details 6.00 6.01 Details Details STEP FOUNDATION ... ... ... ... GAS LINESHOWER NICHE S.N. 1 REVISIONS 4 COURSE 3 COURSE SHEET NO. 1.01 DRAWN BY APPROVED BY REVISIONS CA S T L E H A Y N E , N C DATE THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2012 CI T Y : DATE:07/16/2019 ZI P : ST R E E T : 28 4 2 9 LA Y O U T : JOB NUMBER: REV BU I L D E R S B L I T Z PR O J E C T : FR O N T E L E V A T I O N ( ) MO D E L : IR I S ( ) SE R I E S : HA B I T A T OWNER INITIAL DATE I CERTIFY THESE DRAWINGS ARE CORRECT IN THEIR ENTIRETY. I UNDERSTAND ALL THE BASIC CONSTRUCTION DETAILS IN SO FAR AS THEY ARE RELATIVE TO THE FLOOR PLAN DESIGN, APPEARANCE AND FUNCTIONALITY OF THE HOME. THESE PLANS REPRESENT THE HOME CONTRACTED FOR. IN ADDITION, I UNDERSTAND THAT THESE ARE THE FINAL CONSTRUCTION DRAWINGS AND WILL SUPERSEDE "EXHIBIT A" RENDERING & FLOOR PLAN THAT WAS ATTACHED TO MY CONTRACT AND OR ANY MODEL HOME THAT MAY HAVE BEEN VIEWED. I UNDERSTAND THERE CAN BE NO STRUCTURAL CHANGES AFTER THIS DATE. DATE FINAL INTERNAL REVIEW INITIAL / (AFTER CUSTOMER SIGNATURE) VINYL LAP SIDING 6’ - 6 " PARGE FOUNDATION 8’ - 1 1/2" 12 " 16 ’ - 4 " CORNER BOARD WRAPPED 6X6 POST FINISH FLOOR (F.F.E.) WINDOW HEADER CEILING/PLATE HEIGHT APPROX. RIDGE HEIGHT FINISH GRADE 12 4 12 4 1 1.01 SCALE: 1/4" = 1’-0" FRONT ELEVATION () ... ... ... ... SHEET NO. 1.02 DRAWN BY APPROVED BY REVISIONS CA S T L E H A Y N E , N C DATE THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2012 CI T Y : DATE:07/16/2019 ZI P : ST R E E T : 28 4 2 9 LA Y O U T : JOB NUMBER: REV BU I L D E R S B L I T Z PR O J E C T : LE F T E L E V A T I O N ( ) MO D E L : IR I S ( ) SE R I E S : HA B I T A T OWNER INITIAL DATE I CERTIFY THESE DRAWINGS ARE CORRECT IN THEIR ENTIRETY. I UNDERSTAND ALL THE BASIC CONSTRUCTION DETAILS IN SO FAR AS THEY ARE RELATIVE TO THE FLOOR PLAN DESIGN, APPEARANCE AND FUNCTIONALITY OF THE HOME. THESE PLANS REPRESENT THE HOME CONTRACTED FOR. IN ADDITION, I UNDERSTAND THAT THESE ARE THE FINAL CONSTRUCTION DRAWINGS AND WILL SUPERSEDE "EXHIBIT A" RENDERING & FLOOR PLAN THAT WAS ATTACHED TO MY CONTRACT AND OR ANY MODEL HOME THAT MAY HAVE BEEN VIEWED. I UNDERSTAND THERE CAN BE NO STRUCTURAL CHANGES AFTER THIS DATE. DATE FINAL INTERNAL REVIEW INITIAL / (AFTER CUSTOMER SIGNATURE) PARGE FOUNDATION CORNER BOARD RIDGE VENT RIDGE VENT WRAPPED 6X6 POST SHINGLES AS SPEC’D 6’ - 6 " 8’ - 1 1/2" RIDGE VENT 12 " WRAPPED 6X6 POST FINISH GRADE CEILING/PLATE HEIGHT FINISH FLOOR (F.F.E.) WINDOW HEADER 1 1.02 SCALE: 1/4" = 1’-0" LEFT ELEVATION ... ... ... ... SHEET NO. 1.03 DRAWN BY DRAFT. MGR. REVISIONS CA S T L E H A Y N E , N C DATE THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2018 CI T Y : DATE:07/16/2019 ZI P : ST R E E T : 28 4 2 9 LA Y O U T : JOB NUMBER: REV REV #1 REV #2 REV #3 REV #4 BU I L D E R S B L I T Z PR O J E C T : RI G H T E L E V A T I O N ( ) MO D E L : IR I S ( ) SE R I E S : HA B I T A T OPS. MGR. 12 " 8’ - 1 1/2" SHINGLES AS SPEC’D CORNER BOARD PARGE FOUNDATION VINYL LAP SIDING RIDGE VENT RIDGE VENT WRAPPED 6X6 POST FINISH FLOOR (F.F.E.) CEILING/PLATE HEIGHT FINISH GRADE 1 1.03 SCALE: 1/4" = 1’-0" RIGHT ELEVATION ... ... ... ... SHEET NO. 1.04 DRAWN BY APPROVED BY REVISIONS CA S T L E H A Y N E , N C DATE THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2012 CI T Y : DATE:07/16/2019 ZI P : ST R E E T : 28 4 2 9 LA Y O U T : JOB NUMBER: REV BU I L D E R S B L I T Z PR O J E C T : RE A R E L E V A T I O N ( ) MO D E L : IR I S ( ) SE R I E S : HA B I T A T OWNER INITIAL DATE I CERTIFY THESE DRAWINGS ARE CORRECT IN THEIR ENTIRETY. I UNDERSTAND ALL THE BASIC CONSTRUCTION DETAILS IN SO FAR AS THEY ARE RELATIVE TO THE FLOOR PLAN DESIGN, APPEARANCE AND FUNCTIONALITY OF THE HOME. THESE PLANS REPRESENT THE HOME CONTRACTED FOR. IN ADDITION, I UNDERSTAND THAT THESE ARE THE FINAL CONSTRUCTION DRAWINGS AND WILL SUPERSEDE "EXHIBIT A" RENDERING & FLOOR PLAN THAT WAS ATTACHED TO MY CONTRACT AND OR ANY MODEL HOME THAT MAY HAVE BEEN VIEWED. I UNDERSTAND THERE CAN BE NO STRUCTURAL CHANGES AFTER THIS DATE. DATE FINAL INTERNAL REVIEW INITIAL / (AFTER CUSTOMER SIGNATURE) VINYL LAP SIDING 12 " CORNER BOARD 8’ - 1 1 / 2 " PARGE FOUNDATION WRAPPED 6X6 POST CORNER BOARD PARGE FOUNDATION FINISH FLOOR (F.F.E.) FINISH GRADE 12 4 CEILING/PLATE HEIGHT 12 4 12 4 1 1.04 SCALE: 1/4" = 1’-0" REAR ELEVATION ... ... ... ... SHEET NO. 2.01 DRAWN BY APPROVED BY REVISIONS CA S T L E H A Y N E , N C DATE THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2012 CI T Y : DATE:07/16/2019 ZI P : ST R E E T : 28 4 2 9 LA Y O U T : JOB NUMBER: REV BU I L D E R S B L I T Z PR O J E C T : FI R S T F L O O R P L A N ( ) MO D E L : IR I S ( ) SE R I E S : HA B I T A T OWNER INITIAL DATE I CERTIFY THESE DRAWINGS ARE CORRECT IN THEIR ENTIRETY. I UNDERSTAND ALL THE BASIC CONSTRUCTION DETAILS IN SO FAR AS THEY ARE RELATIVE TO THE FLOOR PLAN DESIGN, APPEARANCE AND FUNCTIONALITY OF THE HOME. THESE PLANS REPRESENT THE HOME CONTRACTED FOR. IN ADDITION, I UNDERSTAND THAT THESE ARE THE FINAL CONSTRUCTION DRAWINGS AND WILL SUPERSEDE "EXHIBIT A" RENDERING & FLOOR PLAN THAT WAS ATTACHED TO MY CONTRACT AND OR ANY MODEL HOME THAT MAY HAVE BEEN VIEWED. I UNDERSTAND THERE CAN BE NO STRUCTURAL CHANGES AFTER THIS DATE. DATE FINAL INTERNAL REVIEW INITIAL / (AFTER CUSTOMER SIGNATURE) 5’-0" 3’-1" 2X6 WALL 6’ - 0 " 11 ’ - 0 " 11 ’ - 0 " 6’ - 0 " 11 ’ - 3 1 / 2 " 5 1 / 2 " 3’ - 4 1 / 2 " 7’- 1 " 7’- 0 1 / 2 " 3’ - 8 " 3’ - 4 " 2’ - 4 1 / 2 " 10’-1"2’-0"2’-0"10’-1 1/2" 3’-0" 5 1/2"5’-5" 6’-8" 14’-5" 2’-8 1/2" 4’-1 1/2" 12’-4 1/2" 4’-6" 1’-8 1/2" 5’-7" 6’- 8 " 6’- 8 " 6’- 8 " 2’ - 1 0 " AI R HA N D L E R 11 ’ - 0 " 3’-1" 12’-4 1/2" 8’ - 1 " 5 1 / 2 " 5 1 / 2 " 6X 6 6X 6 6X 6 6X 6 3’ - 0 " 3’- 0 " 5’-6 1/2" 6X 6 5 1/2" 6’-0" 5 1/2" FLOOR LINE 5’- 8 " 30x68 20x68 24x6 8 50x68 30x6 8 30x68 36 x 3 6 26x68 2-2 0x6 8 30x6 8 67x6 8-D W O 2-2 0x6 8 8/ 0 C L G . 8/ 0 C L G . RANGE 30x68 20x6 8 DRY SP 30x6 8 30 x 6 8 ( F G ) 30 x 68 (FG) 30 5 0 WASH SP 30 5 0 30 5 0 30 5 0 30 5 0 30503030 2x10x8_2YP 2x 1 0 x 1 0 _ 2 Y P 2x10x8_2YP 2x10x8_2YP 2x 1 0 x 8 _ 2 Y P 2x 1 0 x 8 _ 2 Y P 2x 1 0 x 8 _ 2 Y P 6’ - 1 " 14 ’ - 1 1 " 21 ’ - 0 " 20 ’ - 0 " 41 ’ - 0 " 6’-0"2’-0"26’-0"6’-0" 40’-0" 9’ - 2 " 11 ’ - 9 " 4’ - 1 " 25 ’ - 0 " 6’- 1 1 " 9’ - 1 " 41 ’ - 0 " 7’-8"12’-1"8’-3" 6’-0" 3’ - 1 1 " 28’-0"6’-0" 40’-0" WR A P P O S T 5’-0" 2x 1 0 x 1 2 S Y P 2x 1 0 x 1 2 S Y P 8/ 0 C L G . PO R C H 8/ 0 C L G . BE D R O O M # 2 ST O R A G E BA T H 2’-8 1/2" 2x 1 0 x 1 2 S Y P 2 x 1 0 x 1 2 S Y P 2x 1 0 x 1 2 S Y P 2x 1 0 x 1 2 S Y P DI N I N G RO O M 8’ - 1 " x 1 4 ’ - 5 " 2’ - 1 " 3’- 5 " 3’-8"2’-4" 5 1 / 2 " 5 1/2" 36 REF-SPACE W.H . 8/ 0 C L G . MA S T E R BE D R O O M 11 ’ - 3 " x 1 2 ’ - 4 " 2x10x12 SYP 2x10x12 SYP 2x10x12 SYP KI T C H E N 11 ’ - 0 " x 1 0 ’ - 1 " BE D R O O M # 3 11 ’ - 0 " x 1 0 ’ - 1 " BA T H PO R C H 8/ 0 C L G . LI V I N G RO O M 11 ’ - 0 " x 1 4 ’ - 5 " 5 SHLVS 1 R & 1 S 5 S H L V S 1 R & 1 S 1 R & 1 S WS-3.2 6.00 WS-3.2 1 R & 1 S 1 2.01 FRAMING NOTES: 1). Box out 4 1/2" Not 5" 2). Do Not set in for plywood at slab. 3). Ask supervisor about HVAC/Storage areas. 4). Ask supervisor about 9 1/2" overhangs. 5). Double up bottom plate @ ext. walls (cut 1 1/2" off ext. studs). 6). Use materials list provided by supervisor. 7). Do all vinyl preparation for vinyl contractor (fir porches/corners, etc.). 8). Uplift on house and porch walls (ask supervisor about rear porch). 9). See Elevation Sheets for Plate/Ceiling heights 10). Set windows at 7’-0" above finish floor (A.F.F.) U.N.O. 11). Dimensions are from face of framing. Int. walls figured at 3 1/2" 12). NOTIFY CONTRACTOR OF ANY FRAMING DISCREPANCIES. 13). Roof trusses to be designed and engineered by supplier. 14). Do not scale drawings for framing purposes. 15). Verify options. SCALE: 1/4" = 1’-0" FIRST FLOOR PLAN () ... ... ... ... SHEET NO. 3.01 DRAWN BY APPROVED BY REVISIONS CA S T L E H A Y N E , N C DATE THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2012 CI T Y : DATE:07/16/2019 ZI P : ST R E E T : 28 4 2 9 LA Y O U T : JOB NUMBER: REV BU I L D E R S B L I T Z PR O J E C T : FO U N D A T I O N P L A N ( ) MO D E L : IR I S ( ) SE R I E S : HA B I T A T OWNER INITIAL DATE I CERTIFY THESE DRAWINGS ARE CORRECT IN THEIR ENTIRETY. I UNDERSTAND ALL THE BASIC CONSTRUCTION DETAILS IN SO FAR AS THEY ARE RELATIVE TO THE FLOOR PLAN DESIGN, APPEARANCE AND FUNCTIONALITY OF THE HOME. THESE PLANS REPRESENT THE HOME CONTRACTED FOR. IN ADDITION, I UNDERSTAND THAT THESE ARE THE FINAL CONSTRUCTION DRAWINGS AND WILL SUPERSEDE "EXHIBIT A" RENDERING & FLOOR PLAN THAT WAS ATTACHED TO MY CONTRACT AND OR ANY MODEL HOME THAT MAY HAVE BEEN VIEWED. I UNDERSTAND THERE CAN BE NO STRUCTURAL CHANGES AFTER THIS DATE. DATE FINAL INTERNAL REVIEW INITIAL / (AFTER CUSTOMER SIGNATURE) 9’- 1 " 21 ’ - 0 " 20 ’ - 0 " 41 ’ - 0 " 6’-0"2’-0"26’-0"6’-0" 40’-0" 25 ’ - 0 " 6’- 1 1 " 9’ - 1 " 41 ’ - 0 " 6’-0"28’-0"6’-0" 40’-0" D-5 . 1 6.0 0 2-C-5 1 D-1 . 3 6.0 0 M-12 - 1 3 D-1.3 6.00 M-12-13 D-1.3 6.00 M-12-13 D-1 . 5 6.0 0 M-12 - 1 5 D-1 . 3 6.0 0 M-12 - 1 3 36 REF-SPACE W.H . FOUNDATION PLAN NOTES: 1). Verify upgrades w/ supervisor. 2). Provide conduit / wiring at slab. 3). Threaded rods avg. 12" from all corners - AVOID 16" CENTERS 1 3.01 SCALE: 1/4" = 1’-0" FOUNDATION PLAN () ... ... ... ... SHEET NO. 4.01 DRAWN BY APPROVED BY REVISIONS CA S T L E H A Y N E , N C DATE THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2012 CI T Y : DATE:07/16/2019 ZI P : ST R E E T : 28 4 2 9 LA Y O U T : JOB NUMBER: REV BU I L D E R S B L I T Z PR O J E C T : RO O F P L A N ( ) MO D E L : IR I S ( ) SE R I E S : HA B I T A T OWNER INITIAL DATE I CERTIFY THESE DRAWINGS ARE CORRECT IN THEIR ENTIRETY. I UNDERSTAND ALL THE BASIC CONSTRUCTION DETAILS IN SO FAR AS THEY ARE RELATIVE TO THE FLOOR PLAN DESIGN, APPEARANCE AND FUNCTIONALITY OF THE HOME. THESE PLANS REPRESENT THE HOME CONTRACTED FOR. IN ADDITION, I UNDERSTAND THAT THESE ARE THE FINAL CONSTRUCTION DRAWINGS AND WILL SUPERSEDE "EXHIBIT A" RENDERING & FLOOR PLAN THAT WAS ATTACHED TO MY CONTRACT AND OR ANY MODEL HOME THAT MAY HAVE BEEN VIEWED. I UNDERSTAND THERE CAN BE NO STRUCTURAL CHANGES AFTER THIS DATE. DATE FINAL INTERNAL REVIEW INITIAL / (AFTER CUSTOMER SIGNATURE) 4/12 4/12 RIDGE VENT RIDGE VENT RIDGE VENT 4/12 4/12 EV-1.5 6.00 EV_SID_1.5 ROOF FRAMING NOTES: EAVE: GABLE: DORMER (FRONT & SIDES) 1 4.01 SCALE: 1/4" = 1’-0" ROOF PLAN 17" 12" 6" 1: 2: 3: 4: 5: 6: 7: OVERHANG NOTES: ... ... ... ... DIMENSIONS ARE FROM FACE OF FRAMING ROOF TRUSSES TO BE DESIGNED AND ENGINEERED BY SUPPLIER VERIFY CONFIGURATION W/ TRUSS PLANS TRUSSES TO DETERMINE OVERHANG FROM FACE OF EXTERIOR VENEER UNLESS NOTED OTHERWISE AT LOCATION NOTIFY CONTRACTOR OF ANY PLAN DISCREPANCIES R=RIDGE, H=HIP, V=VALLEY VERIFY OPTIONS ALL OVER FRAMED AREAS ARE TO MATCH THE SPACING .4166 SOFFIT INLET 5"= 1.114 OUTLET 00.00 000.00 REQUIRED CALCULATIONS: 00 RIDGE LINEAL FT.1.114 RIDGE OUTLET 000 = .4166 INLET PROVIDED: x x 000.00 00.00 OUTLETINLET+ INLET= 0000 RIDGE VENT 12"LINEAL FOOT SOFFIT VENT 13.375" LINEAL FOOT ATTIC VENTILATION 12" OUTLET= =000.00 NET FREE -CALCULATIONS SHOWN CONSIDER VENTILATION USED AT LEAST 3 FEET ABOVE CORNICE VENTS. -CATHEDRAL CEILINGS SHALL HAVE A MINIMUM OF 1" CLEARANCE BETWEEN THE BOTTOM OF THE ROOF DECK AND THE INSULATION. SOFFIT + RIDGE / (1/150 = .006) =ROOF SQ. FT.000.00 EAVE PERIMETER .006 NC RESIDENTIAL CODE R806.2 MINIMUM AREA: THE TOTAL NET FREE VENTILATION AREA SHALL NOT BE LESS THAN 1/150 OF THE SPACE VENTILATED PROVIDED NET FREE.000 REQUIRED NET FREE= 36 x 3 6 RANGEDRY SPWASH SP 36 REF-SPACE W.H . SHEET NO. 5.01 DRAWN BY APPROVED BY REVISIONS CA S T L E H A Y N E , N C DATE THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2012 CI T Y : DATE:07/16/2019 ZI P : ST R E E T : 28 4 2 9 LA Y O U T : JOB NUMBER: REV BU I L D E R S B L I T Z PR O J E C T : FI R S T F L O O R E L E C T R I C A L P L A N ( ) MO D E L : IR I S ( ) SE R I E S : HA B I T A T OWNER INITIAL DATE I CERTIFY THESE DRAWINGS ARE CORRECT IN THEIR ENTIRETY. I UNDERSTAND ALL THE BASIC CONSTRUCTION DETAILS IN SO FAR AS THEY ARE RELATIVE TO THE FLOOR PLAN DESIGN, APPEARANCE AND FUNCTIONALITY OF THE HOME. THESE PLANS REPRESENT THE HOME CONTRACTED FOR. IN ADDITION, I UNDERSTAND THAT THESE ARE THE FINAL CONSTRUCTION DRAWINGS AND WILL SUPERSEDE "EXHIBIT A" RENDERING & FLOOR PLAN THAT WAS ATTACHED TO MY CONTRACT AND OR ANY MODEL HOME THAT MAY HAVE BEEN VIEWED. I UNDERSTAND THERE CAN BE NO STRUCTURAL CHANGES AFTER THIS DATE. DATE FINAL INTERNAL REVIEW INITIAL / (AFTER CUSTOMER SIGNATURE) S S S S D 1 X 4 D S SS S 3 SSS S SSS S S 42" GFI D D D 42" 20 0 AM P TV GFI S TV 42" WP 42" S3 LC F P 2 X 4 S 4 3 3 WP 42 " 42" 42"GFI WP WP TV TV S 1 5.01 SCALE: 1/4" = 1’-0" FIRST FLOOR ELECTRICAL PLAN () ... ... ... ... D3 S CFP HANGING C S S 3 S 4 S D S LCFP Clg GFI D WP 220 TV DF S AFI BATH STRIP LIGHT FLUORESCENT PACKAGE LIGHTED CEILING FAN PACKAGE CEILING FAN PACKAGE VANITY GLOBE LIGHT U.C. PENDANT UNDER CABINET LIGHT FIXTURE PENDANT LIGHT FIXTURE SC AMP SMOKE DETECTOR WALL/CLG GENERAL NOTE: ELECTRICAL FIXTURES, SWITCHES, OUTLETS, ETC. ARE APPROXIMATE LOCATIONS. LOCATIONS MAY VARY BASEED ON FRAMING AND OR LOCAL CODE CEILING FIXTURE - FLUSH MOUNT DIMMER SWITCH -- FAN DUPLEX OUTLET CEILING OUTLET GROUND FAULT INTERRUPT FLOOR OUTLET DOOR BELL CHIMES ARC FAULT INTERRUPT TELEVISION OUTLET DEDICATED OUTLET WATERPROOF OUTLET HIGH VOLTAGE OUTLET (220) TELEPHONE OUTLET ELECTRICAL PANEL FLOOD LIGHT W/ MOTION DETECTOR L BATH FAN BATH FAN / LIGHT COMBO LIGHTING OUTLET HANGING CEILING FIXTURE WALL FIXTURE SINGLE RECESSED CAN LIGHT FIXTURE EXTERIOR WALL FIXTURE RECESSED EYEBAL CAN FIXTURE SINGLE POLE SWITCH THREE WAY SWITCH FOUR WAY SWITCH DIMMER SWITCH SWITCH AND OUTLET DIMMER SWITCH -- 3-WAY GFI42 DUPLEX OUTLET - COUNTERTOP42 GROUND FAULT INTERRUPT - CNTRTOP CARBON SMOKE DETECTOR WALL/CLG SHEET NO. 6.00 DRAWN BY DRAFT. MGR. REVISIONS CA S T L E H A Y N E , N C DATE THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2018 CI T Y : DATE:07/16/2019 ZI P : ST R E E T : 28 4 2 9 LA Y O U T : JOB NUMBER: REV REV #1 REV #2 REV #3 REV #4 BU I L D E R S B L I T Z PR O J E C T : DE T A I L S ( ) MO D E L : IR I S ( ) SE R I E S : HA B I T A T OPS. MGR. D-5.1 SCALE: 3/4"=1’-0" PORCH DETAIL (REAR) 12" 24" GRADE PORCH SLAB 3000# CONC. FOOTING W/ 2) #5 REBAR CONTINUOUS (MIN. 25" OVERLAP AT ALL SPLICES) CO O R D I N A T E W / TR U S S P L A N S OPTIONAL GUTTER (COORD. W/ SPEC’S) EV 1.5 SCALE: 1" = 1’-0" EAVE - (VINYL BOXING/NO FRIEZE) INSUL. AS SPEC’D INSUL. AS SPEC’D 1/2" GYP. BD. 1/2" GYP. BD. CLG. WEATHER RESISTANT BARRIER (2) 2x4 TOP PLATE 2X4 STUDS @ 16" O.C. SIDING (COOR. TYP W/ ELEVATIONS) 1/2" ROOF DECKING RAFTER TIE COOR. W/ TRUSS PLANS ROOF SHINGLES AS SPEC’D METAL DRIP EDGE FLASHING W/ GUTTER TRUSS ENGIN. BY MFR. VENTED VINYL SOFFIT METAL COIL WRAP FASCIA SYNTHETIC ROOF UNDERLAYMENT 1’-5" 12 SEE ROOF PLAN 2x4 FRAMING 24" O.C. BASE D-1.3 SCALE: 3/4"=1’-0" TYP. WALL FOOTING DETAIL (12" MONO) GRADE COMPACTED FILL THICKENED SLAB EDGES W/ 2 #5 CONT. 4" FIBER REINFORCED CONC. SLAB W/ 6 MIL. POLY VAPOR BARRIER 3" 3" 1’-4" 3" 3" 1’ - 0 " MI N . 8" MI N . 1’ - 8 " M I N . DOUBLE 2X4 PLATE, BOTTOM PLATE ONLY IS TREATED (SEAL BOT. PLATE FOR AIR INFILTRATION) 1/2" STRUCTURAL SHEATHING 1/2" GYP. BD. 2x4 STUDS @ 16" O.C. 5/8" DIA. ANCHOR BOLTS @ 8’-0" OC. LOCATE 12" FROM PLATE ENDS WEATHER RESISTANT BARRIER SIDING (COOR. TYP W/ ELEVATIONS) D-1.5 SCALE: 3/4"=1’-0" PORCH DETAIL (12" MONO) PORCH SLAB 1’-4" 1’ - 0 " 4" 3000# CONC. FOOTING W/ 2) #5 REBAR CONTINUOUS (MIN. 25" OVERLAP AT ALL SPLICES) 1’ - 0 " 1’-4"COMPACTED FILL 4" FIBER REINFORCED CONC. SLAB W/ 6 MIL. POLY VAPOR BARRIER DOUBLE 2X4 PLATE, BOTTOM PLATE ONLY IS TREATED (SEAL BOT. PLATE FOR AIR INFILTRATION) 4" THICKENED SLAB EDGES W/ 2 #5 CONT. 1/2" DIA. ANCHOR BOLTS @ COLUMN LOCATIONS 5/8" DIA. ANCHOR BOLTS @ 8’-0" OC. LOCATE 12" FROM PLATE ENDS SIDING (COOR. TYP W/ ELEVATIONS) 1’ - 8 " M I N . 3" 3" 6 MIL VAPOR BARRIER 5/8" DIA. ANCHOR BOLTS @ 8’-0" OC. LOCATE 12" FROM PLATE ENDS SIDING (COOR. TYP W/ ELEVATIONS) COMPACTED FILL 3000# FIBER REINFORCED CONC. W/ 2) #5 REBAR CONTINUOUS (MIN. 25" OVERLAP AT ALL SPLICES) 12 " MI N . 1’-4" 1’ - 8 " M I N . 8" MI N . 3"3" 3" (1 1 ’ - 0 1 / 2 " ) SHINGLED AS SPEC’D OVER 15# FELT OVER 1/2" SHEATHING TRUSS BY SUPPLIER RAFTER CLIP AS REQ’D INSULATION AS SPEC’D 1/2" STRUCTURAL SHEATHING 2x6 STUDS @ 12" O.C. 4" FIBER REINFORCED CONC. SLAB INSULATION AS SPEC’D X 12 SEE PLAN 1/2" GYP. BD. WS 3.2 SCALE: 3/4"=1’-0" 2X6 EXT. WALL SECTION (SIDING-12" MONO) 15 1/2" COORDINATE W/ EAVE DETAL DOUBLE 2x6 PLATE, BOTTOM PLATE ONLY IS TREATED (SEAL BOT. PLATE FOR AIR INFILTRATION) (0’-0’’) F.F.E.