HomeMy WebLinkAboutIris Left PorchSERIES:
SHEET NO.
THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2018
0.00COVER SHEET ()
HABITATSTREET:
ZIP:
PROJECT:
28429
JOB NO.
LAYOUT:
CASTLE HAYNE, NCCITY:MODEL:IRIS ()
BUILDERS BLITZ
ELEVATIONS 1
ELEVATIONS 2
FLOOR PLAN
FLOOR PLA - ALT BATH
FOUNDATION PLAN
ROOF PLANS
ELECTRICAL PLAN
ELECTRICAL PLAN - ALT BATH
PROJECT INFORMATION
"FINISHED SQUARE FOOTAGE CALCULATIONS
FOR THIS HOUSE WERE MADE BASED ON PLANDIMENSIONS AND MAY VARY FROM THE FINISHEDSQUARE FOOTAGE OF THE HOUSE AS BUILT."
BONUS ROOM (F.O.B.)0 SQ.FT.
1st. FLOOR (F.O.B.)
2nd. FLOOR (F.O.B.)
1.01
1.02
2.01
2.02
3.01
4.01
5.01
5.02
TABLE OF CONTENTS
0
SQ.FT.
SQ.FT.
1148
1148 SQ.FT.
GARAGE (F.O.B.)SQ.FT.0
PRESPECTIVE REPRESENTATION
RENDERING MAY NOT MATCH ELEVATIONS OR PLANS AND IS STRICTLYA REPRESNTATION OF 3D MODEL.
UNFINISHED BASEMENT
FRONT PORCH
BACK PORCH
TOTAL:(F.O.B.)
SQ.FT.0
SQ.FT.
SQ.FT.
120
55
PATIO SQ.FT.0
COVER SHEET
ARCHITECTURAL
0.00
COVER SHEET
VINYL LAP SIDING
12
"
CORNER BOARD
8’-
1
1
/
2
"
PARGE FOUNDATION
WRAPPED 6X6 POST CORNER BOARD
PARGE FOUNDATION
FINISH FLOOR (F.F.E.)
FINISH GRADE
12
4
CEILING/PLATE HEIGHT
12
4
12
4
SERIES:
SHEET NO.
THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2018
1.02LEFT ELEVATION ()
HABITATSTREET:
ZIP:
PROJECT:
28429
JOB NO.
LAYOUT:
CASTLE HAYNE, NCCITY:MODEL:IRIS ()
BUILDERS BLITZ
PARGE FOUNDATION
CORNER BOARD
RIDGE VENT RIDGE VENT
WRAPPED 6X6 POST
SHINGLES AS SPEC’D
6’-
6
"
8’-
1
1/2"
RIDGE VENT
12
"
WRAPPED 6X6 POST
FINISH GRADE
CEILING/PLATE HEIGHT
FINISH FLOOR (F.F.E.)
WINDOW HEADER
VINYL LAP SIDING
6’-
6
"
PARGE FOUNDATION
8’-
1
1/2"
12
"
16
’
-
4
"
CORNER BOARD
WRAPPED 6X6 POST
FINISH FLOOR (F.F.E.)
WINDOW HEADER
CEILING/PLATE HEIGHT
APPROX. RIDGE HEIGHT
FINISH GRADE
12
4
12
4
12
"
8’-
1
1/2"
SHINGLES AS SPEC’D
CORNER BOARD
PARGE FOUNDATION
VINYL LAP SIDING
RIDGE VENT
RIDGE VENT
WRAPPED 6X6 POST
FINISH FLOOR (F.F.E.)
CEILING/PLATE HEIGHT
FINISH GRADE
SCALE: 1/8"=1’-0"
LEFT ELEVATION
SCALE: 1/8"=1’-0"
RIGHT ELEVATION
SCALE: 1/8"=1’-0"
REAR ELEVATION
SCALE: 1/8"=1’-0"
FRONT ELEVATION
ELEVATION 2
SERIES:
SHEET NO.
THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2018
2.01FIRST FLOOR PLAN ()
HABITATSTREET:
ZIP:
PROJECT:
28429
JOB NO.
LAYOUT:
CASTLE HAYNE, NCCITY:MODEL:IRIS ()
BUILDERS BLITZ
5’-0"
3’-1"
2X6 WALL6’-
0
"
11
’
-
0
"
11
’
-
0
"
6’-
0
"
11
’
-
3
1
/
2
"
5 1
/
2
"
3’-
4
1
/
2
"
7’-
1
"
7’-
0
1
/
2
"
3’-
8
"
3’-
4
"
2’-
4
1
/
2
"
10’-1"2’-0"2’-0"10’-1 1/2"
3’-0"
5 1/2"5’-5" 6’-8" 14’-5"
2’-8 1/2" 4’-1 1/2" 12’-4 1/2"
4’-6" 1’-8 1/2" 5’-7"
6’-
8
"
6’-
8
"
6’-
8
"
2’-
1
0
"
AIR
HA
N
D
L
E
R
11
’
-
0
"
3’-1"
12’-4 1/2"
8’-
1
"
5 1
/
2
"
5 1
/
2
"
6X
6
6X
6
6X
6
6X
6
3’-
0
"
3’-
0
"
5’-6 1/2"
6X
6
5 1/2"
6’-0"
5 1/2"
FLOOR LINE
5’-
8
"
30x68
20x68
24x6
8
50x68
30x6
8
30x68
36
x
3
6
26x68
2-2
0x68
30x68
67x6
8-D
W
O
2-2
0x6
8
8/0
C
L
G
.
8/0
C
L
G
.
RANGE
30x68
20x6
8
DRY SP
30x68
30 x
6
8 (F
G
)
30 x 68 (FG)
305
0
WASH SP
30
5
0
30
5
0
30
5
0
30
5
0
30503030
2x10x8_2YP
2x
1
0
x
1
0
_
2
Y
P
2x10x8_2YP
2x10x8_2YP
2x
1
0
x
8
_
2
Y
P
2x
1
0
x
8
_
2
Y
P
2x
1
0
x
8
_
2
Y
P
6’-
1
"
14
’
-
1
1
"
21
’
-
0
"
20
’
-
0
"
41
’
-
0
"
6’-0"2’-0"26’-0"6’-0"
40’-0"
9’-
2
"
11
’
-
9
"
4’-
1
"
25
’
-
0
"
6’-
1
1
"
9’-
1
"
41
’
-
0
"
7’-8"12’-1"8’-3"
6’-0"
3’-
1
1
"
28’-0"6’-0"
40’-0"
WR
A
P
P
O
S
T
5’-0"
2x1
0
x
1
2
S
Y
P
2x
1
0
x
1
2
S
Y
P
8/0
C
L
G
.
PO
R
C
H
8/0
C
L
G
.
BE
D
R
O
O
M
#
2
ST
O
R
A
G
E
BA
T
H
2’-8 1/2"
2x1
0
x
1
2
S
Y
P
2
x
1
0
x
1
2
S
Y
P
2x
1
0
x
1
2
S
Y
P
2x
1
0
x
1
2
S
Y
P
DI
N
I
N
G
RO
O
M
8’-
1
"
x
1
4
’
-
5
"
2’-
1
"
3’-
5
"
3’-8"2’-4"
5 1
/
2
"
5 1/2"
36 REF-SPACE
W.H
.
8/0
C
L
G
.
MA
S
T
E
R
BE
D
R
O
O
M
11
’
-
3
"
x
1
2
’
-
4
"
2x10x12 SYP 2x10x12 SYP
2x10x12 SYP
KI
T
C
H
E
N
11
’
-
0
"
x
1
0
’
-
1
"
BE
D
R
O
O
M
#
3
11
’
-
0
"
x
1
0
’
-
1
"
BA
T
H
PO
R
C
H
8/0
C
L
G
.
LI
V
I
N
G
RO
O
M
11
’
-
0
"
x
1
4
’
-
5
"
5 SHLVS
1 R
&
1
S
5 SH
L
V
S
1 R
&
1
S
1 R & 1 S
WS-3.2
6.00
WS-3.2
1 R & 1 S
SCALE: 1/8"=1’-0"
FLOORPLAN
SERIES:
SHEET NO.
THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2018
3.01FOUNDATION PLAN ()
HABITATSTREET:
ZIP:
PROJECT:
28429
JOB NO.
LAYOUT:
CASTLE HAYNE, NCCITY:MODEL:IRIS ()
BUILDERS BLITZ
9’-
1
"
21
’
-
0
"
20
’
-
0
"
41
’
-
0
"
6’-0"2’-0"26’-0"6’-0"
40’-0"
25
’
-
0
"
6’-
1
1
"
9’-
1
"
41
’
-
0
"
6’-0"28’-0"6’-0"
40’-0"
D-5
.
1
6.0
0
2-C-51
D-1
.
3
6.0
0
M-12-13
D-1.3
6.00
M-12-13
D-1.3
6.00
M-12-13
D-1
.
5
6.0
0
M-12-15
D-1
.
3
6.0
0M-12-13
36 REF-SPACE
W.H
.
SCALE: 1/8"=1’-0"
FOUNDATION PLAN ()
SERIES:
SHEET NO.
THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2018
4.01ROOF PLAN ()
HABITATSTREET:
ZIP:
PROJECT:
28429
JOB NO.
LAYOUT:
CASTLE HAYNE, NCCITY:MODEL:IRIS ()
BUILDERS BLITZ
4/12
4/12
RIDGE VENT
RIDGE VENT
RIDGE VENT
4/12
4/12
EV-1.5
6.00
EV_SID_1.5
SCALE: 1/8"=1’-0"
ROOF PLAN
36
x
3
6
RANGEDRY SPWASH SP
36 REF-SPACE
W.H
.
SERIES:
SHEET NO.
THIS DRAWING IS THE PROPERTY OF LOGAN HOMES AND IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR PART WITHOUT PERMISSION OF LOGAN HOMES COPYRIGHT 2018
5.01FIRST FLOOR ELECTRICAL PLAN ()
HABITATSTREET:
ZIP:
PROJECT:
28429
JOB NO.
LAYOUT:
CASTLE HAYNE, NCCITY:MODEL:IRIS ()
BUILDERS BLITZ
S
S
S
S
D
1 X 4
D
S
SS
S 3
SSS
S
SSS
S
S
42"GFI
D
D
D 42"
200 AM
P
TV
GFI
S
TV
42"
WP
42"
S3
LC
F
P
2 X 4
S 4
3
3
WP
42
"
42"
42"GFI
WP
WP
TV TV
S
SCALE: 1/4"=1’-0"
ELECTRICAL PLAN
D3 S
CFP
HANGING
C
S
S
3 S
4 S
D S
LCFP
Clg
GFI
D
WP
TV
DF S
AFI
BATH STRIP LIGHT
FLUORESCENT PACKAGE
LIGHTED CEILING FAN PACKAGE
CEILING FAN PACKAGE
VANITY GLOBE LIGHT
U.C.
PENDANT
UNDER CABINET LIGHT FIXTURE
PENDANT LIGHT FIXTURE
SC
AMP
2 or 3 MULTIMEDIA OUTLET
CEILING FIXTURE - FLUSH MOUNT
STRUCTRUAL WIRE PANEL
ELECTRICAL PANEL
FLOOD LIGHT
BATH FAN
BATH FAN / LIGHT COMBO
HANGING CEILING FIXTURE
WALL FIXTURE SINGLE
RECESSED CAN LIGHT FIXTURE
EXTERIOR WALL FIXTURE
RECESSED EYEBAL CAN FIXTURE
Clg
SMOKE DETECTOR WALL/CLG
GENERAL NOTE:
ELECTRICAL FIXTURES, SWITCHES,
OUTLETS, ETC. ARE APPROXIMATE
LOCATIONS. LOCATIONS MAY VARY
BASEED ON FRAMING AND OR LOCAL CODE
DIMMER SWITCH -- FAN
DUPLEX OUTLET
CEILING OUTLET
GROUND FAULT INTERRUPT
FLOOR OUTLET
DOOR BELL & CHIMES
ARC FAULT INTERRUPT
TELEVISION OUTLET
DEDICATED OUTLET
WATERPROOF OUTLET
TELEPHONE OUTLET
SINGLE POLE SWITCH
THREE WAY SWITCH
FOUR WAY SWITCH
DIMMER SWITCH
SWITCH AND OUTLET
DIMMER SWITCH -- 3-WAY
GFI42
DUPLEX OUTLET - COUNTERTOP42
GROUND FAULT INTERRUPT - CNTRTOP
CARBON SMOKE DETECTOR WALL/CLG
CEILING OUTLET - LOW VOLTAGELV
PE (PORCH ENCLOSURE) OUTLET
MM2
S.W.P.