Loading...
TRC Agenda Packet 12-7-20221 TECHNICAL REVIEW COMMITTEE AGENDA December 7, 2022 New Hanover County’s Technical Review Committee (TRC) will meet Wednesday, December 7, 2022 at 2:00 p.m. to discuss the below items. PLEASE NOTE: This meeting will be conducted remotely via teleconference. Interested parties can contact the Planning and Land Use Department at 910-798-7165 for more information. Item 1: Royal Farms at Castle Hayne Rd – Major Site Plan – SITECN-22-000052 Request by Two Farms LLC for a Convenience Store and Drive-Thru Car Wash. The subject property is located at 5224 Castle Hayne. It consists of 5.01 acres and is zoned B-2. The applicant is Chris Bollino with Two Farms Inc. (cbollino@royalfarms.com). The planner assigned is Zach Dickerson (zdickerson@nhcgov.com , 910-798-7450). Item 2: Motts Forest East – Major Subdivision Preliminary Plat – SUBPP-22-0007 Request by Arnold L. Sobol, Aftew Properties, LLC, for a 63-lot performance subdivision. The subject property is located at 474 Jacob Mott Drive. It consists of 23.85 acres and is zoned R-15. The applicant is Phillip G. Tripp, P.E. with Tripp Engineering, P.C.. (ptripp@trippengineering.com). The planner assigned is Amy Doss (adoss@nhcgov.com, 910-798-7571). Item 3: Murray Woods – Major Subdivision Preliminary Plat – SUBPP-22-0009 Request by Robert C.G. Exum, Murrayville Land Holdings, LLC, for a 170-lot performance subdivision. The subject property is located at the end of Murray Farm Road. It consists of 68.06 acres and is zoned R-15. The engineer is John S. Tunstall, P.E. with Norris & Tunstall Consulting Engineers, P.C. (jtunstall@ntengineers.com). The current planner assigned is Amy Doss (adoss@nhcgov.com, 910-798- 7571). Item 4: Lake Pointe – Major Subdivision Preliminary Plat – SUBPP-22-0008 Request by Jimmy Hopkins, American Coastal Development, for a 233-lot performance subdivision. The subject property is located at the 4800 block of Dairy Farm Road. It consists of 112 acres and is zoned R- 15. The engineer is John Wall of the Timmons Group (john.wall@timmons.com). The planner assigned is Robert Farrell (rfarrell@nhcgov.com, 910-798-7164). 2 SKETCH PLANS: Item 5: Sketch Plan Review Request by Jeremy Blair with Paramounte Engineering to redevelop an existing industrially zoned site for a Broadcasting and Production Studio. The subject property is located at 215 N Green Meadows Drive. It consists of 11.5 acres and is zoned I-1. The engineer is Jeremy Blair (jblair@paramounte-eng.com). The planner assigned is Amy Doss (adoss@nhcgov.com, 910-798-7571). Item 6: Sketch Plan Review Request by Mike Nichols with Paramounte Engineering for a general retail development. The property is located at located at 3400 Castle Hayne Road. It consists of 11.5 acres and is zoned R-20. The engineer is Mike Nichols (mnichols@paramounte-eng.com). The planner assigned is Zach Dickerson (zdickerson@nhcgov.com, 910-798-7450). This meeting is open to the public by calling 1-336-218-2051 and entering Phone Conference ID: 593 283 909# Castle Hayne Royal Farms – B-2 – TRC Review Page | 1 To: Chris Bollino, Two Farms LLC (cbollino@royalfarms.com) From: Zach Dickerson Current Planner Date: December 7th, 2022 Energov: SITECN-22-000052 Subject: Royal Farms on Castle Hayne Rd, B-2 The following comments have been received for the December 7th, 2022 TRC meeting. Additional comments may be made upon further review of subsequent revisions. Please note: following the TRC meeting, a revised preliminary plan addressing each of the below items must be resubmitted prior to receiving plan approval. Planning, Zach Dickerson 910-798-7450 1. Zoning: B-2 a. Use: Convenience Store, Gas Station & Car Wash 2. General Comments: a. Please be sure to apply for a demolition permit prior to demolishing the existing structures on the property. b. Are these parcels proposed to be recombined? c. Are any traffic calming devices planned for this development? 3. Parking: a. For the six spaces noted in the inset below, please confirm whether there will be curbing, curb stops or bollards to prevent cars from rolling forward. Castle Hayne Royal Farms – B-2 – TRC Review Page | 2 4. Tree Retention: a. Please apply for a Tree Removal Permit. b. Please be aware that a Tree Removal Permit is required prior to any land disturbance activities. Please provide the specific species (Loblolly Pine, Long Leaf Pine, etc.) of the trees to be removed or retained to determine required mitigation. i. Clearly illustrate what trees are being preserved and what trees are proposed to remain. ii. Please see the chart below for an example of what Staff is looking for as a tree inventory requirement. c. All specimen trees located within subject tract are required to be illustrated as well. UDO Section 5.3.5.C The removal of any specimen tree is prohibited on any parcel unless exempt according to Section 10.3.11, Variance Zoning and Subdivision. If a specimen tree is removed without a permit, the penalty for this violation shall be twice the mitigation fee. d. Please be aware that there are optional incentives for retaining trees on site, UDO Section 5.3.8.A.2. e. Please see the chart below indicating the documented, significant, and specimen trees regulated by the County. f. Per UDO Section 5.3.4.C, of the UDO requires a minimum of 15 trees at least 2” DBH must be retained or planted on the parcel where development occurs for each acre or proportionate area disturbed. Please add a note to the Landscape Plan showing has this requirement has been met. i. Please note that required landscaping for the project can be credited to meet this requirement, however, required landscaping does not count towards mitigation, if applicable. g. Per UDO Section 5.3.6.B, please be aware that prior to any construction activity protection fencing is required around protected trees or tree stands. The fencing shall be a minimum of four feet and shall remain in place through completion of construction activities. h. When submitting for the Tree Removal Permit, please include a Tree Inventory Table. 5. Landscaping: Castle Hayne Royal Farms – B-2 – TRC Review Page | 3 a. Please provide a detailed landscape plan schedule illustrating the requirements for interior landscaping, street yards, foundation planting, and buffers have been met. 6. Lighting: a. Please note that with the latest update to the UDO, a lighting plan is not required at time of TRC Approval. See below excerpt from Section 5.5.3: i. Information about the exterior lighting for the site that demonstrates compliance with the standards in this section shall be submitted in conjunction with an application for site plan approval (Section 10.3.6, Site Plan) or zoning compliance approval (Section 10.3.8, Zoning Compliance Approval), whichever comes first, approved no later than at time of construction plan approval. b. Lighting plan is in compliance. 7. Signs: a. Please note that all signs are subject to section 5.6 of the UDO. b. Please submit for sign permits prior to installation. 8. Please provide all NCDOT approvals upon receipt. Please be aware that no building permit will be issued until NCDOT has issued the Driveway Permit approval. 9. FYI - The UDO was recently amended to allow more flexibility in the minimum parking standards. Required parking can now be reduced with a parking demand study. See Section 5.1.3 for more information. Fire Services, Ray Griswold 910-798-7458 1. All properties where Buildings will be demolished shall have proper Demolition Permits through the New Hanover County Building Safety Dept. 2. There shall be fire hydrants located at every street intersection as the proposed Fire Water main is developed. These include, Garden Place Drive, Prince George Ave., N. College Road. 3. Move the on-site fire hydrant down to the entrance off Castle Hayne Road at the driveway entrance. 4. Appendix J - Building Information Signage shall be enforced out of the North Carolina Fire Prevention Code. 5. All proper permits for the underground fuel storage tanks shall be obtained from the New Hanover County Building Safety Dept. NHC Engineering, Galen Jamison 910-798-7072 1. The stormwater permit application has been reviewed and request for additional information was sent to the designer via email on November 9, 2022. Please resubmit the additional information for County permit issuance. 2. Please check with NC DEQ for the requirements of a state stormwater permit. 3. A land disturbing permit issued by the County is required and is currently under review. Any additional information necessary will be requested from the engineer. 4. The existing 60” RCP that bisects the project carries offsite stormwater that qualifies for NHC Stormwater Services maintenance. A public drainage easement sized in accordance with Section 50.2.8 will be required. The easement shall be located outside of the gas pump canopy. Proposed CI10 and CI17 shall be evaluated to minimize impacts should the 60” RCP need to be replaced. Consideration should be given to moving the structures away from the 60” RCP. Any construction proposed on the offsite drainage conveyance measures that will be maintained by the county will need to be observed during construction by Stormwater Services and a turnover meeting Castle Hayne Royal Farms – B-2 – TRC Review Page | 4 scheduled once the system is ready to be conveyed to the county. Please add a plan note and show in plan view to ensure county construction observation and a turnover meeting occurs. Note, should the applicant elect to maintain the 60” RCP themselves, deed restrictions shall indicate the operation and maintenance roles and responsibilities and be recorded. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 1. No CFPUA water and Sewer Available NCDOT, Nick Drees 910-398-9100 1. These preliminary comments and are based on the plans as submitted for the proposed site and are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. 2. NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT Online Portal. 3. A NCDOT Driveway Permit is required. Submit a plan in accordance with pages 14 and 15 of the Policy on Street and Driveway Access to North Carolina Highways to include access locations within 500’ of the proposed access on both sides of the State Road. Submit to the local NCDOT District Engineer’s Office. a. Show/label the 10’x70’ NCDOT Sight Triangles, no obstructions are to be placed in these per the policy manual. b. Label the stem lengths for the driveway connections, these must meet the approved WMPO approval letter. c. Pavement markings will be reviewed during the NCDOT review process. 4. An NCDOT Encroachment Agreement is required for any utility connections or installation within NCDOT right-of-way. a. The utilities will be reviewed once submitted in the NCDOT Encroachment Portal. Environmental Health, Dustin Fenske 910-798-7324 1. Site plan shows connection to a force main and public sewer. If public sewer cannot be obtained then a septic system permit must be issued prior to construction. The properties with existing dwellings have existing septic systems that must be properly abandoned. The septic tanks must be located then pumped, crushed and filled for proper abandonment. 2. Site plan reflects the site will connect to public water. If public water cannot be connected then a well permit must be issued by the appropriate regulating agency (NC Public Water Division or local Environmental Health). The existing structures on these tracts have existing wells that must be located, protected and properly abandoned by a certified well driller. Abandonment of all wells is critical due to the nature of proposed construction. The UST's must maintain 100' separation from any adjacent properties wells. Castle Hayne Royal Farms – B-2 – TRC Review Page | 5 WMPO, Jamar Johnson 910-343-3915 1. The turning template for trucks shows inadequate clearance for the curb and crossing of centerline of exiting drive aisle. Revise driveway design dimensions to provide adequate room. 2. According to the approved TIA for this site, the following improvements are required of the development: a. US 117 (N College Road) at Site Access 1 (Proposed stop-controlled T-intersection) • Construct site access (northbound approach) with one ingress and two egress lanes, configured as one left turn lane and one right turn lane • Provide stop control for northbound approach. • Provide an internal protected stem of 125 feet measured from the right-of-way • Construct an eastbound right turn lane on US 117 with 100 feet of storage, 50 feet of full width deceleration and appropriate taper • Construct a westbound left turn lane on US 117 with 100 feet of storage, 50 feet of full width deceleration and appropriate taper b. NC 133 (Castle Hayne Road) at Site Access 2 (Proposed Right-in/Right-out Intersection) • Construct site access (westbound approach) with one ingress and one egress lane • Provide stop control for westbound approach • Provide an internal protected stem of 75 feet measured from the right-of-way • Construct a northbound right turn lane on NC 133 with 75 feet of storage, 50 feet of full width deceleration and appropriate taper Planning (Addressing), Katherine May 910-798-7443 1. No comments. Current address is acceptable. Army Corps of Engineers, Brad Shaver 910-251-4611 Castle Hayne Royal Farms – B-2 – TRC Review Page | 6 1. A wetland delineation has been completed by this office and the current plan shows a potential impact that will require permitting by the Corps. MEMORANDUM To: New Hanover County Technical Review Committee Date: 11/23/22 Subject: Royal Farms #482 – Castle Hayne Comments: • The turning template for trucks shows inadequate clearance for the curb and crossing of centerline of exiting drive aisle. Revise driveway design dimensions to provide adequate room. Royal Farms #482 – WMPO TRC Comments 2 According to the approved TIA for this site, the following improvements are required of the development: US 117 (N College Road) at Site Access 1 (Proposed stop-controlled T-intersection) • Construct site access (northbound approach) with one ingress and two egress lanes, configured as one left turn lane and one right turn lane • Provide stop control for northbound approach • Provide an internal protected stem of 125 feet measured from the right-of-way • Construct an eastbound right turn lane on US 117 with 100 feet of storage, 50 feet of full width deceleration and appropriate taper • Construct a westbound left turn lane on US 117 with 100 feet of storage, 50 feet of full width deceleration and appropriate taper NC 133 (Castle Hayne Road) at Site Access 2 (Proposed Right-in/Right-out intersection) • Construct site access (westbound approach) with one ingress and one egress lanes • Provide stop control for westbound approach • Provide an internal protected stem of 75 feet measured from the right-of-way • Construct a northbound right turn lane on NC 133 with 75 feet of storage, 50 feet of full width deceleration and appropriate taper NCDOT Projects: TIP Projects in the Area: N/A WMPO 2045 Projects: N/A New Hanover County CTP: N/A TIA: Development has a TIA approval with conditions letter dated September 7, 2022. All improvements are required to be constructed for the development. Motts Forest East – Performance Residential Preliminary Site Plan – TRC Review Page | 1 To: Phillip G. Tripp, P.E., Tripp Engineering, P.C. ptripp@trippengineering.com From: Amy Doss Current Planner Date: December 7th, 2022 Energov: SUBPP-22-0007 Subject: Motts Forest East – Commercial Site Plan – TRC Review The following comments have been received for the December 7th, 2022 TRC meeting. Additional comments may be made upon further review of subsequent revisions. Please note: following the TRC meeting, a revised preliminary plan addressing each of the below items must be resubmitted prior to receiving preliminary plan approval. Planning, Amy Doss 910-798-7571 1. Zoning: R-15 a. Use: Performance Residential. It appears that the proposal generally meets the requirements specified in UDO Sections 3.2.8 and 3.1.3.D, requiring performance residential dwellings in the R-15 districts to comply with the following standards specified in UDO. 2. General Comments: a. As a recommendation please clearly show ADA accessible connections and warning strips to the sidewalks in the required locations. b. Please label entry gates. c. Please show sight triangles for ingress/egress at all access points. d. Please clearly indicate the location for any proposed signage, if applicable, UDO Section 5.6. e. Will there be any mail kiosks? If so, please provide a paved area with ingress/egress and parking as required by UDO Section 6.2.2.A.15. 3. Open space conforms with UDO Section 5.8.2.2, with the proposal showing slightly more than 20% of the design containing 23.85 acres of with a proposed 4.95 acres of open space. 4. Tree Retention: a. Please apply for a Tree Removal Permit. Motts Forest East – Performance Residential Preliminary Site Plan – TRC Review Page | 2 b. Please be aware that a Tree Removal Permit is required prior to any land disturbance activities. Please provide the specific species (Loblolly Pine, Long Leaf Pine, etc.) of the trees to be removed or retained to determine required mitigation. c. Please clearly illustrate what trees are being preserved and what trees are proposed to remain. d. All specimen trees located within subject tract are required to be illustrated as well. UDO Section 5.3.5.C The removal of any specimen tree is prohibited on any parcel unless exempt according to Section 10.3.11, Variance Zoning and Subdivision. If a specimen tree is removed without a permit, the penalty for this violation shall be twice the mitigation fee. e. Please be aware that there are optional incentives for retaining trees on site, UDO Section 5.3.8.A.2. f. Please see the chart below indicating the documented, significant, and specimen trees regulated by the County. g. Per UDO Section 5.3.4.C, of the UDO requires a minimum of 15 trees at least 2” DBH must be retained or planted on the parcel where development occurs for each acre or proportionate area disturbed. Please add a note to the Landscape Plan showing has this requirement has been met. Please note that required landscaping for the project can be credited to meet this requirement, however, required landscaping does not count towards mitigation, if applicable. h. Per UDO Section 5.3.6.B, please be aware that prior to any construction activity protection fencing is required around protected trees or tree stands. The fencing shall be a minimum of four feet and shall remain in place through completion of construction activities. i. Tree inventory plans are required to reflect the trees being retained and the trees being removed clearly. Please see the example below, which illustrate the trees with the X’s being removed and the trees and the trees being preserved showing the protection in the correct placement. Motts Forest East – Performance Residential Preliminary Site Plan – TRC Review Page | 3 j. Please include the tree data within a table as shown below. 5. Easements: a. UDO Section 6.2.2, please ensure all Storm Sewer, Sanitary Sewer, and Water Main Utility Easements are labeled. 6. Roadway Design: a. Please verify that the tangent lengths meet the code requirements specified by the County’s private road standards. 7. Lighting: a. Please note that with the latest update to the UDO, a lighting plan is not required at time of TRC Approval. See below excerpt from Section 5.5.3: i. Information about the exterior lighting for the site that demonstrates compliance with the standards in this section shall be submitted in conjunction with an application for site plan approval (Section 10.3.6, Site Plan) or zoning compliance approval (Section 10.3.8, Zoning Compliance Approval), whichever comes first, approved no later than at time of construction plan approval. b. The lighting plan should illustrate that street lighting, all exterior lighting, and indoor lighting visible from outside shall be designed and located so that the maximum illumination measured in foot candles at ground level at a residential lot line meet the UDO Section 5.5. Please refer to Table 5.5.4.B of the UDO for additional standards. 8. Please note that no building permit for any structure shall be issued which requires NCDOT approval for a Driveway Permit until NCDOT has issued the approval. Evidence of approval shall accompany the application for building permit. Fire Services, David Stone 910-798-7458 1. Roads and driveways: a. All-weather, hard surface access is required during construction to accommodate fire apparatus weighing at least 85,000 pounds. (NCFC D102.1) b. Minimum road width with fire hydrants is 26 feet with no on -street parking. (NCFC D103.1) c. Vertical clearance of 13’ 6” is required over the full width of all roads. (NCFC 503.2.1) d. Road grade shall not exceed 10%. (NCFC: D103.2) e. Dead-end roads exceeding 150 feet in length require an approved turnaround. (NCFC: 503.1.1; D103.4; Table D103.4) Motts Forest East – Performance Residential Preliminary Site Plan – TRC Review Page | 4 f. Clarification needed: shaded area from the cul-de-sac, between lots 55, 56, and 62 leading to lot 63. g. Cul-de-sacs must have a minimum diameter of 96 feet. (NCFC D103.4 & Table D103.4) Minimum turning radius for fire apparatus is 45 feet within the curbs with no on-street parking. (NCFC 103.3) h. Gates: If not continuously attended, electric gates must have a Knox key override switch and a siren activated opener for emergency vehicle access. Manual gates must have a Knox padlock to allow for Fire Department access. Gates must be able to be opened in the event of a power outage. 2. Traffic Calming Devices: Highly discouraged as they delay emergency response of all types and cause damage. Speed bumps or humps are prohibited. Other traffic calming devices must be submitted and evaluated during the Technical Review process. (NCFC 503.4.1) 3. Other Considerations: a. The NCFC requires a viable water supply at time of construction. 1. Options: install water mains and hydrants or use a nearby existing hydrant system. A temporary water tank is a suggestion in the NCFC, but is discouraged. 1. Approved hydrant locations: 1. between lots 7/8 2. between lots 28/29 3. on lot 43 b. Hydrants must meet CFPUA standards and be free from obstructions within a 3’ radius minimum. (Examples: streetlights, utility boxes or equipment, transformers, substantial landscaping that could obscure they hydrant at maturity, etc.) c. Street or road signs: Temporary signage is required at each intersection once construction of roadways allow for passage of any vehicles and shall be maintained until they are replaced with permanent signage. d. Address identification: premises identification is required with a minimum of 6 inches in height and a ¾ inch brush stroke. NHC Engineering, Galen Jamison 910-798-7072 1. A land disturbing and a stormwater permit issued by the County are required for this project in addition to the State stormwater permit. Please submit for permits as the design is completed. 2. The existing ditches located in lots 30-33 may require additional tree removal. Please coordinate proposed grading with the tree removal plan as the design is completed. 3. Please ensure via a lot grading plan or proposed contours the all impervious surfaces for the perimeter lots are directed to the proposed stormwater control measures. 4. Please indicate the proposed well site by Aqua on the existing conditions mapping. 5. The wetland mapping note indicates a date of 2011 which is outside the 5 year timeframe for wetlands determination. Please verify with the authorities having jurisdiction. 6. The discharge from the pond appears to result in stormwater turning greater than 90 degrees and doesn’t appear to connect to the existing conveyance system. It is recommended the pond outfall piping be aligned better with the existing discharge pattern to the south and additional survey be obtained to verify existing elevations and contours. Motts Forest East – Performance Residential Preliminary Site Plan – TRC Review Page | 5 Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 1. CFPUA TRC Comments provided are preliminary comments only. 2. Utility Plan review required by CFPUA. CFPUA is moving toward becoming paperless. When ready to submit plan review package, upload all documents to https://www.cfpua.org/FormCenter/Engineering-3/Engineering-Plan-Review-103. 3. CFPUA sewer available through a mainline extension to serve the subdivision. 4. NC Aqua water. 5. At this time capacity is available 6. Capacity is also dependent on the analysis of the pipe collection system (gravity and force mains). 7. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE Application Form and a Preliminary Plan, this determination does not guarantee capacity. 8. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the Authority. Environmental Health, Dustin Fenske 910-798-6732 1. Proposed public sewer force mains and manholes must maintain setbacks to existing wells at 5700 and 5704 Carolina Beach Rd. along with wells of properties on Grand Champion Rd. Setbacks are 50 feet from a force main and 100 feet from a manhole to existing wells. NCDOT, Nick Drees/Mike Frank, 910-398-9100 1. These preliminary comments and are based on the plans as submitted for the proposed site and are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. 2. NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT Online Portal. 3. A NCDOT Driveway Permit is required. Submit a plan in accordance with pages 14 and 15 of the Policy on Street and Driveway Access to North Carolina Highways to include access locations within 500’ of the proposed access on both sides of the State Road. Submit to the local NCDOT District Engineer’s Office. a. This section of Jacob Mott Drive is not currently state maintained; however, a petition has been received to add and is currently under review. b. Landscaped islands will need to be labeled and designed according to NCDOT policy. c. Per Note 3 “ALL ROADS SHALL BE BUILT PRIVATE”, the subject roads will not be eligible to be added to the state system at any time. i. Subsequently notes 13 and 14 are obsolete unless NHC is making this a requirement. ii. The “typical” should show private r/w and should meet the construction requirements of NHC. “A” mix would not meet NCDOT’s current requirements either. 4. Driveway connections for lots 1, 38, 39 and, 60 should be located as far from Jacob Mott Drive as possible. 5. What are the proposed access points for lots 61-63? 6. An NCDOT Encroachment Agreement is required for any utility connections or installation within NCDOT right-of-way. US Army Corps of Engineers Brad Shaver 1. A wetland delineation has been approved by the Corps that included both jurisdictional wetland and non-jurisdictional wetland (regulated by the State). It appears that the federally regulated jurisdictional wetlands may be avoided in the submitted plan. Motts Forest East – Performance Residential Preliminary Site Plan – TRC Review Page | 6 Addressing, Katherine May 910-798-7443 1. Parcel address is 551 Jacob Mott Drive (PID: R07600-006-012-000) 2. Mark mail kiosks. New subdivisions do not get individual mailboxes. 3. Please contact me with the final plat, following TRC approval, to start the addressing process. 4. Subdivision name of Heron Hill is approved. 5. Street Names: 4 will be required. a. Heron Hill – Approved. b. Motts Village East – No directionals, too close to “Motts Village Road”, not approved. c. Douglas - Approved. d. Negley – Approved. e. Northumberland – No directionals, not approved. f. Wessex – Approved. g. Blue Heron – Taken, not approved. h. Squirrel Hill – Approved. 6. Street suffixes (Rd, St, Dr, etc.) are chosen based on the physical characteristics of the street. a. Red: Lane, Place, Row, Run, Way b. Green: Lane, Place, Row, Run, Way c. Blue: Lane, Row, Run, Way d. Yellow: Lane, Place, Row, Run, Way WMPO, Jamar Johnson 910-343-3915 No comments Comments not received at this time from: Emergency Services & E911, Steve Still NCDEQ, Chad Coburn New Hanover Soil & Water, Dru Harrison USACE, Rachel Capito NCDEMLR, Dan Sams DCM, Tanya Pietila New Hanover County Schools, Laura Severt Murray Woods – Performance Residential Preliminary Site Plan – TRC Review Page | 1 To: John S. Tunstall, P.E., Norris & Tunstall Consulting Engineers, P.C. jtunstall@ntengineers.com From: Amy Doss Current Planner Date: December 7th, 2022 Energov: SUBPP-22-0009 Subject: Murray Woods – Performance Residential – Preliminary Plan Major Subdivision – TRC Review The following comments have been received for the December 7th, 2022 TRC meeting. Additional comments may be made upon further review of subsequent revisions. Please note: following the TRC meeting, a revised preliminary plan addressing each of the below items must be resubmitted prior to receiving preliminary plan approval. Please update the plan with the following general corrections: Planning, Amy Doss 910-798-7571 1. Zoning: R-15 a. Use: Performance Residential. It appears that the proposal generally meets the requirements specified in UDO Sections 3.2.8 and 3.1.3.D, requiring performance residential dwellings in the R-15 districts to comply with the following standards specified in UDO. 2. General Comments: a. As a recommendation please clearly show ADA accessible connections and warning strips to the sidewalks in the required locations. b. Please show sight triangles for ingress/egress at all access points. c. Please list setbacks that apply to R-15 Performance Residential on Sheet C0, as noted in UDO Section 3.1.3.D.1. d. Please clearly indicate the location for any proposed signage, if applicable, UDO Section 5.6. e. Please show the location of your mail kiosk and the paved area with ingress/egress and parking as required by UDO Section 6.2.2.A.15.A paved area with ingress/egress to allow vehicles to pull off , park, and re-enter the roadway safely shall be required for each kiosk Murray Woods – Performance Residential Preliminary Site Plan – TRC Review Page | 2 area. Kiosks shall be located in areas that will best allow for vehicle parking, which shall be designated so as not to create pedestrian or vehicle safety issues. 3. Please indicate if the streets will be public or private. 4. Open Space: a. Please label and provide calculations for open space to comply with UDO Section 5.8.2.2. 5. Tree Retention: a. Please apply for a Tree Removal Permit. b. Please be aware that a Tree Removal Permit is required prior to any land disturbance activities. Please provide the specific species (Loblolly Pine, Long Leaf Pine, etc.) of the trees to be removed or retained to determine required mitigation. c. Existing trees must be inventoried by a cover type survey conducted by point sampling, fixed plot sampling, field survey or other method approved by the Planning Director. Areas that will not be disturbed shall be delineated as such and do not require inventorying individual trees. d. All specimen trees located within subject tract are required to be illustrated as well. UDO Section 5.3.5.C The removal of any specimen tree is prohibited on any parcel unless exempt according to Section 10.3.11, Variance Zoning and Subdivision. If a specimen tree is removed without a permit, the penalty for this violation shall be twice the mitigation fee. e. Please be aware that there are optional incentives for retaining trees on site, UDO Section 5.3.8.A.2. f. Please see the chart below indicating the documented, significant, and specimen trees regulated by the County. g. Per UDO Section 5.3.4.C, of the UDO requires a minimum of 15 trees at least 2” DBH must be retained or planted on the parcel where development occurs for each acre or proportionate area disturbed. Please add a note to the Landscape Plan showing has this requirement has been met. Please note that required landscaping for the project can be credited to meet this requirement, however, required landscaping does not count towards mitigation, if applicable. Murray Woods – Performance Residential Preliminary Site Plan – TRC Review Page | 3 h. Per UDO Section 5.3.6.B, please be aware that prior to any construction activity protection fencing is required around protected trees or tree stands. The fencing shall be a minimum of four feet and shall remain in place through completion of construction activities. i. Tree inventory plans are required to reflect the trees being retained and the trees being removed clearly. Please see the example below, which illustrate the trees with the X’s being removed and the trees and the trees being preserved showing the protection in the correct placement. j. Please include the tree data within a table as shown below. 6. Easements: a. UDO Section 6.2.2, please ensure all Storm Sewer, Sanitary Sewer, and Water Main Utility Easements are clearly labeled. 7. Lighting: a. Please note that with the latest update to the UDO, a lighting plan is not required at time of TRC Approval. See below excerpt from Section 5.5.3: i. Information about the exterior lighting for the site that demonstrates compliance with the standards in this section shall be submitted in conjunction with an application for site plan approval (Section 10.3.6, Site Plan) or zoning compliance approval (Section 10.3.8, Zoning Compliance Approval), whichever comes first, approved no later than at time of construction plan approval. b. The lighting plan should illustrate that street lighting, all exterior lighting, and indoor lighting visible from outside shall be designed and located so that the maximum illumination measured in foot candles at ground level at a residential lot line meet the UDO Section 5.5. Please refer to Table 5.5.4.B of the UDO for additional standards. 8. Please note that no building permit for any structure shall be issued which requires NCDOT approval for a Driveway Permit until NCDOT has issued the approval. Evidence of approval shall accompany the application for building permit. 9. Traffic: a. County Staff concurs that no full analysis would have to be conducted due to the data already being gathered meeting our ordinance requirements consistent with the “standards, practices, and policies” of DOT and MPO and described in the ordinance. Please see attached letter for more information. b. Please show the location of any traffic calming devices. Murray Woods – Performance Residential Preliminary Site Plan – TRC Review Page | 4 Fire Services, David Stone 910-798-7458 1. Roads and driveways: a. All-weather, hard surface access is required during construction to accommodate fire apparatus weighing at least 85,000 pounds. (NCFC D102.1) b. Minimum road width with fire hydrants is 26 feet with no on-street parking. (NCFC D103.1) c. On-street parking on roads greater than 26 feet is only permitted on ONE side of the road, on the side opposite the fire hydrants. d. Vertical clearance of 13’ 6” is required over the full width of all roads. (NCFC 503.2.1) e. Road grade shall not exceed 10%. (NCFC: D103.2) f. Connectivity: requirements are based on project size and occupancy type. (NCFC D106 and D107) g. Clarification needed: Is there connectivity to an adjacent development? i. road appears to end at Lot 30 [> 150’] ii. road appears to end between Lots 82 and 169/170 [=150’] iii. road appears to end adjacent to Lot 1 [=150’] h. Signage is required on the dead-end roads to prevent on-street parking. (NCFC D103.6) i. Gates: If not continuously attended, electric gates must have a Knox key override switch and a siren activated opener for emergency vehicle access. Manual gates must have a Knox padlock to allow for Fire Department access. Gates must be able to be opened in the event of a power outage. j. Traffic Calming Devices: Highly discouraged as they delay emergency response of all types and cause damage. Speed bumps or humps are prohibited. Other traffic calming devices must be submitted and evaluated during the Technical Review process. (NCFC 503.4.1) 2. Other Considerations: a. The NCFC requires a viable water supply at time of construction. Options: install water mains and hydrants or use a nearby existing hydrant system. A temporary water tank is a suggestion in the NCFC--but is discouraged. 1. Approved hydrant locations: a. between lots 10/11 b. corner at lot 18 c. corner of lot 52 d. between lots 60/61 e. corner of lot 72 f. between lots 80/81 g. corner of lot 92 h. between lots 97/98 i. between lots 117/118 j. corner of lot 125 k. between lots 147/148 l. corner at lot 161 b. Hydrants must meet CFPUA standards and be free from obstructions within a 3’ radius minimum. (Examples: streetlights, utility boxes or equipment, transformers, substantial landscaping that could obscure they hydrant at maturity, etc.) c. Street or road signs: Temporary signage is required at each intersection once construction of roadways allow for passage of any vehicles and shall be maintained until they are replaced with permanent signage. Murray Woods – Performance Residential Preliminary Site Plan – TRC Review Page | 5 d. Address identification: premises identification is required with a minimum of 6 inches in height and a ¾ inch brush stroke. NHC Engineering, Galen Jamison 910-798-7072 1. A land disturbing and a stormwater permit issued by the County are required for this project in addition to the State stormwater permit. Please submit for permits as the design is completed. 2. Please ensure via a lot grading plan or proposed contours all the impervious surfaces for the perimeter lots are directed to the proposed stormwater control measures. 3. Please provide 10’ of access road for pond maintenance as the existing trees to remain appear to impact the access requirement. 4. Will the filling of the existing ditch originating at lot 93 have impact any upstream drainage? 5. Note, the reconstruction of the outfall ditch along Springer Road is anticipated to be completed in early 2023. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 1. CFPUA TRC Comments provided are preliminary comments only. 2. Utility Plan review required by CFPUA. CFPUA is moving toward becoming paperless. When ready to submit plan review package, upload all documents to https://www.cfpua.org/FormCenter/Engineering-3/Engineering-Plan-Review-103. 3. CFPUA water and sewer available through a mainline extension to serve the subdivision. 4. At this time capacity is available; DWQ permit application will require a Planning FTSE. 5. Capacity is also dependent on the analysis of the pipe collection system (gravity and force mains). 6. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE Application Form and a Preliminary Plan, this determination does not guarantee capacity. 7. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the Authority. Environmental Health, Dustin Fenske 910-798-6732 1. Subdivision plans state the site will be on public water and sewer. Lift station for subdivision must maintain 100' setback from wells located at 6557, 6539 and 6551 Murrayville Rd. All other infrastructure improvements appear to meet setbacks to surrounding properties well and septic systems. NCDOT, Nick Drees/Mike Frank, 910-398-9100 1. These preliminary comments and are based on the plans as submitted for the proposed site and are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. 2. Are the proposed roads private? If yes label appropriately. 3. NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT Online Portal. 4. A NCDOT Driveway Permit is required. Submit a plan in accordance with pages 14 and 15 of the Policy on Street and Driveway Access to North Carolina Highways to include access locations within 500’ of the proposed access on both sides of the State Road. Submit to the local NCDOT District Engineer’s Office. 5. Any construction inside public r/w will need to be built per NCDOT Standards and per the approved preliminary plan approval for the appropriate subdivision. 6. An NCDOT Encroachment Agreement is required for any utility connections or installation within NCDOT right-of-way. a. The utilities will be reviewed once submitted in the NCDOT Encroachment Portal. Murray Woods – Performance Residential Preliminary Site Plan – TRC Review Page | 6 US Army Corps of Engineers Brad Shaver 1. A wetland delineation has been approved by the Corps and the current plan appears to avoid these resources. Addressing, Katherine May 910-798-7443 1. Four street names are required. Please submit 4 street names (without suffixes) and 4 alternates for approval. Murray Farms Road and Retriever Drive will be continued from the neighboring subdivision. 2. Mark mail kiosk locations. New subdivisions do not get individual mailboxes. 3. Contact me following TRC approval to start the addressing process. WMPO, Jamar Johnson 910-343-3915 1. No comments. Comments not received at this time from: Emergency Services & E911, Steve Still NCDEQ, Chad Coburn New Hanover Soil & Water, Dru Harrison USACE, Rachel Capito NCDEMLR, Dan Sams DCM, Tanya Pietila New Hanover County Schools, Laura Severt ILM Cold Storage Facility – Commercial Site Plan – Sketch TRC Review Page | 1 To: John Wall, Timmons Group (john.wall@timmons.com) From: Robert Farrell, Senior Planner Date: November 23, 2022 Egov# SUBPP-22-0008 Subject: Lake Pointe Subdivision – Preliminary Plat – TRC Review Planning, Robert Farrell 910-798-7164 1. Zoning: R-15 a. Use: Performance Residential. It appears that the proposal generally meets the requirements specified in UDO Sections 3.2.8 and 3.1.3.D, requiring performance residential dwellings in the R-15 districts to comply with the following standards specified in UDO. 2. General Comments: a. As a recommendation please clearly show ADA accessible connections and warning strips to the sidewalks in the required locations. b. Please show sight triangles for ingress/egress at the Dairy Farm Road access points. c. Please list setbacks that apply to R-15 Performance Residential, as noted in UDO Section 3.1.3.D.1. d. Please show the location of your mail kiosk and the paved area with ingress/egress and parking as required by UDO Section 6.2.2.A.15.A paved area with ingress/egress to allow vehicles to pull off , park, and re-enter the roadway safely shall be required for each kiosk area. Kiosks shall be located in areas that will best allow for vehicle parking, which shall be designated so as not to create pedestrian or vehicle safety issues. e. Include the total acreage of areas occupied by all structures including streets and parking areas. f. An easement will be required with provisions to allow public access to the cemetery on the property. These will need to be included in the covenants. 3. Open Space: a. Please label and provide calculations for open space to comply with UDO Section 5.8.2.2. 4. Tree Retention: a. Please apply for a Tree Removal Permit. b. Please be aware that a Tree Removal Permit is required prior to any land disturbance activities. Please provide the specific species (Loblolly Pine, Long Leaf Pine, etc.) of the trees to be removed or retained to determine required mitigation. ILM Cold Storage Facility – Commercial Site Plan – Sketch TRC Review Page | 2 c. Existing trees must be inventoried by a cover type survey conducted by point sampling, fixed plot sampling, field survey or other method approved by the Planning Director. Areas that will not be disturbed shall be delineated as such and do not require inventorying individual trees. d. All specimen trees located within subject tract are required to be illustrated as well. UDO Section 5.3.5.C The removal of any specimen tree is prohibited on any parcel unless exempt according to Section 10.3.11, Variance Zoning and Subdivision. If a specimen tree is removed without a permit, the penalty for this violation shall be twice the mitigation fee. e. Please be aware that there are optional incentives for retaining trees on site, UDO Section 5.3.8.A.2. f. Please see the chart below indicating the documented, significant, and specimen trees regulated by the County. g. Per UDO Section 5.3.4.C, of the UDO requires a minimum of 15 trees at least 2” DBH must be retained or planted on the parcel where development occurs for each acre or proportionate area disturbed. Please add a note to the Landscape Plan showing has this requirement has been met. Please note that required landscaping for the project can be credited to meet this requirement, however, required landscaping does not count towards mitigation, if applicable. h. Per UDO Section 5.3.6.B, please be aware that prior to any construction activity protection fencing is required around protected trees or tree stands. The fencing shall be a minimum of four feet and shall remain in place through completion of construction activities. i. Tree inventory plans are required to reflect the trees being retained and the trees being removed clearly. Please see the example below, which illustrate the trees with the X’s being removed and the trees and the trees being preserved showing the protection in the correct placement. ILM Cold Storage Facility – Commercial Site Plan – Sketch TRC Review Page | 3 j. Please include the tree data within a table as shown below. 5. Easements: a. UDO Section 6.2.2, please ensure all Storm Sewer, Sanitary Sewer, and Water Main Utility Easements are clearly labeled. 6. Lighting: a. Please note that with the latest update to the UDO, a lighting plan is not required at time of TRC Approval. See below excerpt from Section 5.5.3: i. Information about the exterior lighting for the site that demonstrates compliance with the standards in this section shall be submitted in conjunction with an application for site plan approval (Section 10.3.6, Site Plan) or zoning compliance approval (Section 10.3.8, Zoning Compliance Approval), whichever comes first, approved no later than at time of construction plan approval. b. The lighting plan should illustrate that street lighting, all exterior lighting, and indoor lighting visible from outside shall be designed and located so that the maximum illumination measured in foot candles at ground level at a residential lot line meet the UDO Section 5.5. Please refer to Table 5.5.4.B of the UDO for additional standards. Fire Services – Raymond Griswold (910) 798-7448 1. Fire hydrant layout plan required. 2. Road widths should be identified on the plans. 3. Cul-de-sac diameters should be identified as well. County Engineering – Galen Jamison (910) 798-7072 1. A land disturbing and a stormwater permit issued by the County are required for this project in addition to the State stormwater permit. Please submit for permits as the design is completed. 2. Please provide pedestrian access to the existing cemetery. 3. Please ensure via a lot grading plan or proposed contours all the impervious surfaces for the perimeter lots are directed to the proposed stormwater control measures. The inlets located in the back of the lot will likely need ditches to direct drainage to each inlet. ILM Cold Storage Facility – Commercial Site Plan – Sketch TRC Review Page | 4 4. Please provide the requirements (worker safety, gas venting, etc) for cutting and trenching proposed in the existing landfill. Please provide a copy of any permit requirements for constructing in an existing landfill. 5. Please provide a copy of the no rise certification during the permitting phase of the project. 6. A permit revision will be required for ATC #699-03/09/17, Street Safe project located at 5000 Blue Clay Road. 7. The proposed grading at lot 166 and 167 and proposed inlets appear to capture runoff from adjacent land or may result in ponding on adjacent property. Please ensure these drainage areas are incorporated into the permit calculations or flow is bypassed around the proposed stormwater control measures. 8. A public drainage easement sized in accordance with NHC Stormwater Manual will be required for the floodway along the eastern portion of the development. Cape Fear Public Utility Authority – Bernice Johnson (910) 332-6620 1. CFPUA TRC Comments provided are preliminary comments only. 2. Utility Plan review required by CFPUA. CFPUA is moving toward becoming paperless. When ready to submit plan review package, upload all documents to https://www.cfpua.org/FormCenter/Engineering-3/Engineering-Plan-Review-103. 3. CFPUA water and sewer available through a mainline extension to serve the subdivision; a pump station and forcemain will also be required. 4. At this time capacity is available. 5. Capacity is also dependent on the analysis of the pipe collection system (gravity and force mains). 6. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE Application Form and a Preliminary Plan, this determination does not guarantee capacity. 7. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the Authority. 8. Northern Watermains Cost Recovery Fee, Sidbury Forcemain Cost Recovery Fee and Sidbury Water Cost Recovery Fee will apply. NCDOT, Nick Drees (910) 398-9100 1. These preliminary comments and are based on the plans as submitted for the proposed site and are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. 2. NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT Online Portal. 3. A NCDOT Driveway Permit is required. Submit a plan in accordance with pages 14 and 15 of the Policy on Street and Driveway Access to North Carolina Highways to include access locations within 500’ of the proposed access on both sides of the State Road. Submit to the local NCDOT District Engineer’s Office. a. Show/label the 10’x70’ NCDOT Sight Triangles, no obstructions are to be placed in these per the policy manual. ILM Cold Storage Facility – Commercial Site Plan – Sketch TRC Review Page | 5 b. Show/label sight distances for both driveway connections. Any sight distance issues will need to be cleared and maintained by the applicant/HOA/POA in accordance to NCDOT policy. c. Label the stem lengths for the driveway connections, these must meet the approved WMPO approval letter. d. Pavement markings will be reviewed during the NCDOT review process. 4. An NCDOT Encroachment Agreement is required for any utility connections or installation within NCDOT right-of-way. a. The utilities will be reviewed once submitted in the NCDOT Encroachment Portal. Environmental Health – Dustin Fenske (910) 798-7324 1. Site plan reflects the site will be on public water and sewer. Proposed infrastructure improvements appear to meet all setbacks to surrounding well and septic systems. WMPO – Jamar Johnson (910) 343-3910 See Attached Addressing, Katherine May (910) 798-7443 1. 8 street names are required. Please submit 8 street names (without suffixes) with a few alternates for approval. 2. Mark mail kiosk locations. New subdivisions do not get individual mailboxes. 3. Contact me following TRC approval to start the addressing process. US Army Corps of Engineers, Brad Shaver (910) 251-4611 1. The Corps approved the current delineation and it included both jurisdictional wetlands as well as non-jurisdictional wetlands (regulated by the State). The federally regulated wetlands appear to have been avoided. ILM Cold Storage Facility – Commercial Site Plan – Sketch TRC Review Page | 6 MEMORANDUM To: New Hanover County Technical Review Committee Date: 11/23/22 Subject: Lake Pointe Comments: • The most accurate ITE Code for the townhomes part of the development is ITE Code 215 – Single Family Attached Housing. The TIA used ITE Code 220. The difference in peak hour trips is negligible so no revision is needed to the TIA approval with conditions letter dated October 3, 2022. According to the approved TIA, the following improvements are required of the development: SR 2181 (Old Dairy Farm Road) and SR 2180 (Blue Clay Road)/Site Access 1 • Construct Site Access 1 with an internal protected stem of 100 feet measured from the right- of-way line and one ingress and one egress lane. • Provide stop control for westbound approach. • Construct a northbound right turn lane on SR 2181 (Old Dairy Farm Road) with 50 feet of storage, 50 feet of full-width deceleration and appropriate taper. SR 2181 (Old Dairy Farm Road) and Site Access 2 • Construct Site Access 2 with an internal protected stem of 100 feet measured from the right- of-way line and one ingress and one egress lane. • Provide stop control for westbound approach. • Construct a northbound right turn lane on SR 2181 (Old Dairy Farm Road) with 50 feet of storage, 50 feet of full-width deceleration and appropriate taper. NCDOT Projects: TIP Projects in the Area: N/A WMPO 2045 Projects: N/A Lake Pointe – WMPO TRC Comments 2 New Hanover County CTP: N/A TIA: Development has a TIA approval with conditions letter dated October 3, 2022. All improvements are required to be constructed for the development. OAK 22 OAK 18 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXX X X XXXXXX X X X X X X X X X X XXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X OHE OHE OHE OHE OH E OHE OHE OHE OHE OHE OH E LP LPLP TR X X X X X X X X X X X X X X X X X XXXXXX XXXXXXXXX X X X X X X X X X X X X X X X XX X X X X X X X X X X X X X X XXXXXXXXX X X X X X X OHE OHE OHE OHEOHEOHEOHEOHE OHE OHE OHE OHE OHEOHE O H E O H E O H E OH E OH E OH E OH E OH E OH E OH E OHE OHE O H E OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE LP ELEC. PANEL P J MANAGEMENT GROUP INC R05006-003-002-000 110 HARLEY RD RB-REGIONAL BUSINESS DB 4301, PG 313 US A T O W E R I N C R0 5 0 0 6 - 0 0 3 - 0 0 9 - 0 0 0 11 2 H A R L E Y R D RB - R E G I O N A L B U S I N E S S DB 2 4 1 5 , P G 1 6 6 MU R R A Y M A R L I N G J J A N E T S R0 5 0 0 6 - 0 0 3 - 0 0 5 - 0 0 62 0 9 M A R K E T S T RB - R E G I O N A L B U S I N E S S DB 2 3 2 4 , P G 1 3 8 MARAPESE MICHAEL T KATHERINE T R05006-003-006-000 6211 MARKET ST RB-REGIONAL BUSINESS DB 1584, PG 840 R & M RESTOROATIONS LLC R05006-003-007-000 6213 MARKET ST RB-REGIONAL BUSINESS DB 5247, PG 847 GG PLEASANT LLC R05000-002-005-000 6245 MARKET ST RB-REGIONAL BUSINESS DB 1225, PG 782 HALL LARRY L R05000-002-006-000 6301 MARKET ST RB-REGIONAL BUSINESS DB 3968, PG 790 CROCKER CHARLES R04319-008-001-000 197 GREEN MEADOWS DR N I-1-INDUSTRIAL DISTRICT DB 1678, PG 113 CROCKER CHARLES R04319-008-002-000 201 N GREEN MEADOWS DR I-2-INDUSTRIAL DISTRICT DB 1678, PG 113 CAVENAUGH DUNCAN B ALICE G R04319-008-005-000 217 N GREEN MEADOWS DR I-2-INDUSTRIAL DISTRICT DB 4879, PG 2713 SEECO PROPERTIES LLC R04319-008-004-000 291 N GREEN MEADOWS DR I-2-INDUSTRIAL DISTRICT DB 4658, PG 981 N & W INVESTMENTS LLC R04300-007-019-000 293 N GREEN MEADOWS DR I-2-INDUSTRIAL DISTRICT DB 5875, PG 1184 301 N GREEN MEADOWS DR I-1-INDUSTRIAL DISTRICT DB 2336, PG 662 R04300-007-006-008 301 N GREEN MEADOWS DR I-2-INDUSTRIAL DISTRICT DB 1402, PG 1630 FILIPPINI FAMILY LTD PTNRP R04318-006-002-000 136 HARLEY RD I-1-INDUSTRIAL DISTRICT DB 1318, PG 1184 REGISTER PHILLIP S SUSAN C R04318-006-001-000 128 HARLEY RD I-1-INDUSTRIAL DISTRICT DB 2323, PG 846 HINTON JOHN ROBERT KRIS A R05006-003-001-004 I-1-INDUSTRIAL DISTRICT DB 5691, PG 2456 G GAS TANK ENCLOSURE UELEC. PANEL ELEC. PANEL ELEC. PANEL PROPANE TANK U U U U S S S S S S S S S S S S S S SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS PUMP FLAG POLE FUEL PUMPS ELEC. PANEL ELEC. PANEL ELEC. PANEL U ELEC. PANEL GATE GA T E ELEC. PANEL KEY PAD KEY PAD U GENERATOR GA T E UTIL. VAULT UTIL. VAULT UTIL. MANHOLE UTIL. VAULT G LP GAS TANK EXPANDED STORMWATER POND ±1.13 AC TOTAL EXISTING DRIVEWAY TO BE USED SHARED ACCESS DRIVE 47 EXISTING PARKING SPACES TO REMAIN STAGE ±44,000 SF MILLWORK ±11,000 SF STORAGE ±7,000 SF OFFICE ±11,000 SF EX. BUILDING AND PROPOSED ADDITION (OFFICE & WAREHOUSE) ±6,700 SF HA R L E Y R O A D 60 ' P U B L I C R / W 47 25 83 40 30 . 0 ' 30 . 0 ' 17.8'24.9'18.0'18.0'34.1'18.0' 25 . 7 ' 24.0' 18 . 0 ' 50 ' F R O N T S E T B A C K N. G R E E N M E A D O W S D R I V E 75 ' P U B L I C R / W 24 . 0 ' 30.0' 14.0' 27 6.4' 11 . 3 ' 250.0' 16 3 . 0 ' 51 39.5' 24.0'24.0' 14.0' 3. 5 ' 3.5'3.5' 14 . 0 ' 18 . 0 ' LOADING 4. 0 ' 3 PROPOSED STAGE ±40,750 SF (250'x163') 48 MODIFY EXISTING CURB TO ALIGN WITH PARKING LAYOUT AND SHARED ACCESS DRIVE EXISTING GARAGE TO BE REMAIN SITE INFORMATION PARCEL (PIN):R04300-007-006-001 TOTAL SITE AREA:±11.51 ACRES CLIENT INFORMATION:DARK HORSE STUDIOS EXISTING ZONING: I-1 (LIGHT INDUSTRIAL) CURRENT LAND USE:INDUSTRIAL PROPOSED LAND USE:BROADCASTING & PRODUCTION STUDIO DIMENSIONAL REQUIREMENTS FRONT SETBACK:50' MIN. SIDE SETBACK:0' MIN. SIDE STREET SETBACK:50' MIN. REAR SETBACK:0' MIN. DEVELOPMENT DATA STUDIO BUILDINGS / PROPOSED USES: SOUND STAGES:± 84,750 SF OFFICES:± 11,000 SF MILLWORK SPACE:± 11,000 SF STORAGE (NOT PARKED):± 7,000 SF TOTAL BUILDING AREA:± 113,750 SF TOTAL BUILDING AREA PARKED:± 106,750 SF MINIMUM PARKING REQUIRED:267 SPACES 2.5 SPACES / 1,000 SF PARKING PROVIDED:310 SPACES MATTRESS COMPANY PROPOSED USES: OFFICE SPACE:± 4,000 SF 2.5 SPACES / 1,000 SF 10 SPACES WAREHOUSE SPACE:± 2,700 SF 1.5 SPACES / 1,000 SF 4 SPACES MINIMUM PARKING REQUIRED:14 SPACES 2.5 SPACES / 1,000 SF PARKING PROVIDED:14 SPACES NOTE: PLAN HAS NOT BEEN REVIEWED BY NEW HANOVER COUNTY PLANNING AND ZONING STAFF, BUT A REVIEW IS RECOMMENDED. N O R T H 0 SCALE: 1"=50' at 24"x36" 25'50'100' Prepared by: Date: 16 NOVEMBER 2022 Conceptual Master Plan Dark Horse Studios New Hanover County, North Carolina Preliminary; Not For Construction. This site plan is a graphic representation and should be utilized for discussion purposes only. This site plan approximates existing conditions relating to structures, wetlands, roads, parking, vegetation and property boundaries. Plan componentsmay change based upon regulatory and municipal regulations and requirementsat the time of approvals and/or development activity. EXISTING DRIVEWAY TO REMAIN EXISTING DRIVEWAY AND GATED ACCESS TO REMAIN EXISTING DOCK HEIGHT LOADING AREA TO REMAIN EXISTING LOADING BAY TO BE REMOVED TO PROVIDE FULL ACCESS DRIVEWAY TO REAR OF BUILDING & PARKING AREA RETROFIT SITE TO MAINTAIN OPEN DRIVEWAY ACCESS AS NEEDED REMOVE EXISTING GAS TANK AND FUEL PUMPS MATTRESS COMPANY OFFICE & WAREHOUSE BUILDING EXISTING LOADING AREA TO BE CONVERTED AT GRADE LOADING/DRIVE IN ACCESS CA B I N E T TAB L E TU B DRYER DRYER TU B TA B L E TELE. BOARD 11 0WO M E N ME N IT / E L E C . 11 1 CL O S E T MG R ' S O F F I C E 10 7 PLA S T I C T O P FO L D I N G T A B L E FA X ME T A L BO O K CA S E SA F E PA P E R SH R E D D E R MA N A G E R ' S DES K FIL I N G CA B I N E T IT R A C K ELE C . P A N E L TRA N S BA L E R FR I D G E LO U N G E EM P L O Y E E 10 8 PE T W A S H 11 2 10 9 10 5 CO R R I D O R BO P I S SH E D PE R M A N E N T T R A I L E R A N D E Q U I P M E N T DI S P L A Y A R E A 3 , 0 0 0 S Q . F T . 15 0 ' U T I L I T Y E A S E M E N T MA P B O O K 3 2 P A G E 1 8 5 22 . 5 ' U T I L I T Y E A S E M E N T MA P B O O K 3 2 P A G E 1 8 5 +/ - 2 3 5 ' SA S S A N Q U A R D CH A I R R D TR A C T O R S U P P L Y C O . WI L M I N G T O N , N C EX.-1 02 / 1 6 / 0 6 1" = 1 0 0 ' RP B RP B RP B DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL CL I E N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 CA S T L E H A Y N E R D . NE W H A N O V E R C O U N T Y , N C 00000.00 01 . 0 1 . 1 6 01 . 0 1 . 1 6 01 . 0 1 . 1 6 01 . 0 1 . 1 6 VICINITY MAP SCALE: 1" = 1,000' SITE GLADIOLUS RD. WETLANDS GIS PARCEL INFORMATION FROM NEW HANOVER COUNTY. SITE VISIT PERFORMED TO ESTIMATE EXISTING WETLANDS AS SHOW ON SITE PLAN EXHIBIT. WETLANDS SURVEY WILL BE REQUIRED TO ACCURATELY MAP EXTENTS OF ANY WETLANDS THAT MAY BE LOCATED ON THE SUBJECT PROPERTY. PROPOSED WETLAND DISTURBANCE: +/- 1 ACRE CA S T L E H A Y N E R D . NC R T . 1 3 0 C H A I R R D . C A S T L E H A Y N E R D . STORM WATER +/- 1 ACRE GLADIOLUS RD. GARDEN CENTER +/- 4,000 SF FENCED OUTDOOR DISPLAY AREA +/- 14,000 SF PROPOSED BUILDING +/- 22,000 SF FORAGE SHED 1,250 SF PARKING CALCULATIONS: PARKING PARKING SF / USE RATIO SPACES 19,028 SF / GENERAL RETAIL 2.5 / 1,000 47.6 3,224 SF / FEED SHED (STORAGE)1.5 / 1,000 4.8 1,250 SF / FORAGE SHED (STORAGE)1.5 / 1,000 1.9 4,462 SF / RETAIL NURSERY 2.5 / 1,000 11.2 14,000 SF / OUTDOOR DISPLAY 1.5 / 1,000 21.0 REQUIRED PARKING: 76.5 PARKING PROVIDED: 77 REQUIRED HANDICAP PARKING = 4 SPACES HANDICAP PARKING PROVIDED = 4 SPACES SITE DATA: PROJECT NAME:TRACTOR SUPPLY COMPANY SITE ADDRESS:3400 CASTLE HAYNE RD. CASTLE HAYNE, NC 28429 DEVELOPER:WILMINGTON DEVELOPMENT GROUP, LLC. 120 MARKET SQUARE: SECOND FLOOR PINEHURST, NC 28374 PARCEL ID:R02500-002-009-003 0.77 ACRES R02500-002-021-000 1.66 ACRES R02500-002-022-000 1.71 ACRES R02500-002-020-000 1.73 ACRES R02500-002-009-000 5.72 ACRES PROPOSED PROJECT AREA:+/- 11.52 ACRES PROPERTY OWNER:ASHTON & AVERY, LLC 201 MARSHFIELD DR. WILMINGTON, NC 28411 EXISTING ZONING: R-20 PROPOSED ZONING:CONDITIONAL REZONING COMP. PLAN PLACE TYPE:COMMUNITY MIXED USE JURISDICTION:NEW HANOVER COUNTY PROPOSED USE:RETAIL / COMMERCIAL (TYPE OF DEVELOPMENT) DIMENSION REQUIREMENTS: REQUIRED PROVIDED FRONT YARD SETBACK 20' 20' REAR YARD SETBACK 25'* 25' SIDE YARD SETBACK 20' 20' *INCREASED SETBACK REQUIRED WHERE ADJACENT TO RESIDENTIAL ZONE OR USE MAXIMUM ALLOWABLE HEIGHT: 45' (3 STORIES) PROPOSED HEIGHT: 30' (1 STORY) MAXIMUM FLOOR AREA PER DEVELOPMENT: 100,000 SF PROPOSED FLOOR AREA: +/- 19,028 SF INTERIOR BUILDING +/- 3,224 SF FEED SHED +/- 1,250 SF FORAGE SHED +/- 4,462 SF GARDEN CENTER / GREENHOUSE +/- 14,000 SF EXTERIOR FENCED OUTDOOR DISPLAY SI D E W A L K DI S P L A Y 1 , 0 0 0 S F SI D E W A L K DI S P L A Y 1 , 3 0 0 S F SI D E W A L K DI S P L A Y 68 0 S F TYPE A: OPAQUE BUFFER 20' WIDE (MIN.) 0 25 50 100 200 SCALE: 1"=50' PR E L I M I N A R Y D R A W I N G - N O T F O R C O N S T R U C I T O N GRAPHIC SCALE N O R T H Pr e l i m i n a r y ; N o t F o r C o n s t r u c t i o n . T h i s s i t e p l a n i s a g r a p h i c r e p r e s e n t a t i o n a n d s h o u l d b e u t i l i z e d f o r d i s c u s s i o n p u r p o s e s o n l y . T h i s s i t e p l a n a p p r o x i m a t e s e x i s t i n g c o n d i t i o n s r e l a t i n g t o s t r u c t u r e s , w e t l a n d s , ro a d s , p a r k i n g , v e g e t a t i o n a n d p r o p e r t y b o u n d a r i e s . P l a n c o m p o n e n t s m a y c h a n g e b a s e d u p o n r e g u l a t o r y a n d m u n i c i p a l r e g u l a t i o n s a n d r e q u i r e m e n t s a t t h e t i m e o f a p p r o v a l s a n d / o r d e v e l o p m e n t a c t i v i t y . WETLANDS WETLANDS WETLANDS WE T L A N D S EM E R S O N D R . SA S S A N Q U A R D . DAVIS LN. INTE R S T A T E U S 1 4 0 +/- 41,964 SF PROPOSED DEVELOPMENT EXISTING PORTION OF PROPERTY IN UTILITY EASEMENT TO REMAIN UNCHANGED TYPE A: OPAQUE BUFFER 20' WIDE (MIN.), TO BE SATISFIED WITH EXISTING PLANTINGS IN WETLANDS, SUPPLEMENTED AS NEEDED TO MEET MINIMUM PLANTINGS REQUIRED PER ORDINANCE TYPE A: OPAQUE BUFFER 20' WIDE (MIN.) TYPE A: OPAQUE BUFFER, PROVIDED OUTSIDE OF EXISTING UTILITY EASEMENT 20' WIDE (MIN.) STREET YARD LANDSCAPING AS REQUIRED, SEE CALCULATIONS (9' MIN. / 27' MAX.) FOUNDATION PLANTINGS PAVED DISPLAY AREA (20' X 150') PROPOSED LIMITS OF WETLAND DISTURBANCE (TO BE VERIFIED) PROPOSED LIMITS OF WETLAND DISTURBANCE (TO BE VERIFIED) PARKING LOT (77 SPACES) STREET YARD INSIDE UTILITY EASEMENT TO REMAIN UNDISTURBED, NO NEW LANDSCAPING) PROPOSED DRIVEWAY WB-65 VEHICLE TURNAROUND FOR LOADING DOCK BULK PROPANE TANK (FOR SALE) LOADING DOCK TRASH ENCLOSURE DRIVE LANE 20' SETBACK REQUIRED LANDSCAPE SCREENING AT TRASH ENCLOSURE, PROPANE TANK AND LOADING DOCK 25 ' S E T B A C K 20' SETBACK 20' SETBACK EXISTING RESIDENTIAL PROPERTIES STREET YARD PROPOSED ZONING: B-1 MINIMUM STREET YARD WIDTH: 9' MAXIMUM STREET YARD WIDTH: 27' REQUIRED AREA: 18 SF FOR EVERY LINEAR FT. FRONTAGE CALCULATIONS: SUBJECT PROPERTY STREET FRONTAGE AT CASTLE HAYNE RD.: 489' PORTION OF STREET FRONTAGE IN UTILITY EASEMENT: - 172.5' PORTION OF STREET FRONTAGE AS DRIVEWAY: - 30' STREET YARD FRONTAGE SUBJECT TO LANDSCAPING 286.5' 286.5' X 18 SF = LANDSCAPING REQUIRED IN STREET YARD: 5,157 SF LANDSCAPE PROVIDED IN STREET YARD: 5,316 SF PROPANE TANK (FOR BUILDING USE)