Loading...
TRC Agenda Packet 2-15-20231 TECHNICAL REVIEW COMMITTEE AGENDA February 15, 2023 New Hanover County’s Technical Review Committee (TRC) will meet Wednesday, February 15, 2023 at 2:00 p.m. to discuss the below items. PLEASE NOTE: This meeting will be conducted remotely via teleconference. Interested parties can contact the Planning and Land Use Department at 910-798-7165 for more information. Item 1: Dolan Drive ILM Parking Lot – Major Site Plan – SITECN-23-000002 Request by Granseur Dick of New Hanover County Airport Authority for a new parking lot at ILM International Airport. The new parking lot is approximately 1.89 acres and is zoned Airport Commerce. The engineer is David Stevick with Carolina Engineers, PA (dstevick@carolinaengineers.com). The planner assigned is Zach Dickerson (zdickerson@nhcgov.com, 910-798-7450) This meeting is open to the public by calling 1-336-218-2051 and entering Phone Conference ID: 324 211 330# Wilmington International Airport- Parking Lot Expansion – TRC Review Page | 1 To: David Stevick, PE, Carolina Engineers, (dstevick@carolinaengineers.com) Granseur Dick, PE, New Hanover County Airport Authority (gdick@flyilm.com) From: Zach Dickerson Current Planner Date: February 15, 2022 Subject: ILM International Airport, Parking Lot Expansion TRC Comments Energov: SITECN-23-000002 The following comments have been received for the February 15th, 2022 TRC meeting. Additional comments may be made upon further review of subsequent revisions. Please note: following the TRC meeting, a revised preliminary plan addressing each of the below items must be resubmitted prior to receiving plan approval. Planning, Zach Dickerson 910-798-7450 1. Zoning: AC, Airport Commerce a. Use: Parking for ILM Airport 2. General Comments: a. Please show all proposed locations of signs. b. Please label all rights-of-way, including the name of the road where applicable. c. INV-00094648 is available to be paid for this review. Please pay online at www.nhcgov.com/coast or by calling 910-798-7308. 3. Landscaping (on next page): Wilmington International Airport- Parking Lot Expansion – TRC Review Page | 2 a. Please note that per table 5.4.5.C, no parking space shall be located more than 120 feet from a landscaped island. It appears that some of the middle parking spaces, noted in the image below, do not meet this requirement. 4. Lighting: a. Please indicate any lighting proposed for the site. b. Please note that with the latest update to the UDO, a lighting plan is not required at time of TRC Approval. See below excerpt from Section 5.5.3: i. Information about the exterior lighting for the site that demonstrates compliance with the standards in this section shall be submitted in conjunction with an application for site plan approval (Section 10.3.6, Site Plan) or zoning compliance approval (Section 10.3.8, Zoning Compliance Approval), whichever comes first, approved no later than at time of construction plan approval. c. The lighting plan should illustrate that street lighting, all exterior lighting, and indoor lighting visible from outside shall be designed and located so that the maximum illumination measured in foot candles at ground level at a residential lot line meet the UDO Section 5.5. Please refer to Table 5.5.4.B of the UDO for additional standards. 5. Are any traffic calming devices proposed for the parking lot expansion (speed bumps/speed tables)? Note, these are not required, but if they are planned to be installed, please note on the site plan. Fire Services, Raymond Griswold 910-798-7458 1. With all the growing number of parking lots, I recommend ILM label all parking Lots with appropriate signage. Ie: Employee Parking, Rental Car Parking, Cell Phone Lot, Short Term & Long Term Parking, etc. Keep it visible to all that use it. This will make first responders easier to locate and the folks using it to better identify where they are at. NHC Engineering, Galen Jamison 910-798-7072 1. It appears the drainage for this project is directed to the extended dry detention basin permitted with the State stormwater permit SW8 050547. Please check with the State for permit modifications requirements. Wilmington International Airport- Parking Lot Expansion – TRC Review Page | 3 2. Please submit to NHC Engineering a stormwater permit revision to ATC# 222 as the design is completed. The county’s permit requires all storm sewer conveyance measures (pipes, swales, culverts, etc) be designed to the 25 year event. 3. Please submit to NC DEQ for erosion and sediment control permitting. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 1. No CFPUA Plan Review Required NCDOT, Patrick Wurzel 910-398-9100 1. No comments Environmental Health, Dustin Fenske 910-798-7324 1. Parking lot expansion does not affect well. WMPO, Jamar Johnson 910-343-3915 1. No comments Planning (Addressing), Katherine May 910-798-7443 1. No comments Comments not received at this time from: