Loading...
HomeMy WebLinkAboutApplication_Sunset Reach 9.13.2017_____________________________________________________________________________________________________________________________________ 3805CherryAvenueͲWilmington,NC28403Ͳ9107914441Ͳwww.csdͲengineering.com–License#CͲ2710 September12,2017   SamBurgess NewHanoverCounty PlanningDepartment 230GovernmentCenterDrive Wilmington,NorthCarolina28403   Re:PreliminaryPlan SunsetReach NewHanoverCounty CSDProjectNo.13Ͳ0304  DearSam:  TherecentreͲsubmissionoftheSunsetReachPreliminaryPlanwasduetotheplanhavingexpired.Thisproject isquiteafewyearsoldwithoutanyofthelotsbeingplatted,butalotofinternalworkhasbeencompletedonthesite. Alltheroadsarepaved,gravitysewer,forcemainsewer,domesticwaterandstormdrainageinfrastructurehavebeen installed.Theonlyutilitycomponentnotcompletedisthesewerpumpstationwhichiscurrentlyunderreviewwith CFPUA.  Originally,thesiteproposedtohavesepticfieldsattheentrancetothesubdivisiontobeutilizedforsomeofthelotsso homebuildingcouldbeginwhilethedesignandinstallationbytheCFPUAofanewsewerforcemainrunningthrough thissitetoconnecttotheadjacentsubdivisionofRiverBluffswascompleted.Thesitesatdormantforafewyearswith nobuildingoccurringandwaspickedupbynewownerswhowantedtoutilizeconnectingtothenewforcemainsothe areaoriginallyreservedforsepticfieldscouldnowbeutilizedforbuildablelots.Thatistheprogressionofwherethesite isnowwithamaxdensityof68lots.ThesitehasNHCandNCDEQstormwaterpermitsbothofwhichwearepreparing tosubmitrevisedapplicationsforreviewtoaccountfortheincreaseinlotsfromwhentheoriginalpermitswereissued. ArevisedNHCECapplicationisbeingsubmittedtoshowthelotsshrinkwrappedinsiltfencesinceallthemassgrading hasalreadytakenplaceonsite.  Ifyouhaveanyquestionsorcomments,pleasefeelfreetocontactme.Thankyouforyourassistance.   Sincerely,      RodneyWright   Page 1 of 1 PRD 05/10 SUBMISSION REQUIREMENTS The application will be regarded as incomplete until the following items are received by Planning & Zoning. Your application must include a $300.00 fee and 15 folded maps of the proposed Performance Residential Development. This fee should be payable to New Hanover County and must accompany this application. Applications for Performance Residential Development are received and acted upon by the County’s Technical Review Committee. Planning & Zoning staff will send a copy to each appropriate agency. Written agency comments must be received three (3) weeks prior to the meeting before being placed on the TRC agenda. 1. Streets - Written comments from the North Carolina Department of Transportation approving the design of all public streets or a letter from the County Engineer approving the design of all private streets. 2. Water and Sewer- A letter from the appropriate State or local health agency approving the design of such systems and commitment allocation to serve the project. 3. Drainage- The location of all marshes, watercourses, ditches, drainage channels, with proposed drainage and utility easements water and sewer for the proposed subdivision. 4. A letter from the Soil Conservation Service indicating any acreage from Class IV soils on the property. 5. A letter from County Fire Services approving fire hydrant location and street design. 6. You are encouraged to arrange an informal conference with planning staff at least two (2) weeks prior to submitting an application. By attending this conference, you will improve your chances of submitting a complete and acceptable application. You should bring a rough sketch of your proposal to this conference. Planning & Zoning staff will proceed to advise you of environmental problems, point out significant design problems, describe the required improvements, and advise you regarding the required approval letters for water and sewer. A checklist outlining these requirements is available to help you through this process. I certify that all information presented in this application is accurate to the best of my knowledge. ____________________________________________ ________________________________________ Signature of Property Owner and/or Developer Print Name Name of Applicant or Owner Date of Application Address City, State, Zip Email Address Telephone Number of Owner Name of Surveyor (if different than Owner) Telephone Number of Surveyor (if different than Owner) Address of Surveyor (if different than Owner) City, State, Zip Email Address (if different than Owner) Parcel ID Number Location of Property Square Feet/Acres on Plat Project Name Land Classification NEW HANOVER COUNTY PLANNING & INSPECTIONS DEPARTMENT PERFORMANCE RESIDENTIAL DEVELOPMENT 230 Government Center Drive Suite 110 Wilmington, NC 28403 910-798-7165 phone 910-798-7053 fax www.nhcgov.com Page 1 of 2 PRC 05/10 Site Plan Requirements (Section 51.5-2 of Zoning Ordinance) Scale no smaller than one inch to two hundred feet (1”=200’) Vicinity or location map Name of designer, engineer, or surveyor North arrow and date Owner’s name, address, and phone number on plan Developer (if other than owner) and development name Boundary line of tract to be developed drawn accurately to scale with bearings and distance dimensions Tax map, block and parcel numbers Total gross acres in tract Total acres occupied by all structures including street right-of-way and parking areas Total acres & boundaries of land lying within the 100-year flood plain and below mean high water mark, plus delineation of 100-year flood boundary Boundaries of all open space areas Location of all existing and proposed structures Total number of dwelling units to be constructed with number of bedrooms per unit and location of all multiple dwelling units Location of right-of-way widths of all streets and easements (and other areas to be dedicated to public use) Location and width of all streets, plus names and designation Location and description of all recreational areas and facilities Location of natural features including topographical information (contour interval 2 feet), watercourses, approximate forest lines and topo source Location and size of all proposed utility and drainage facilities Areas to be maintained by association clearly indicated on plan 20’ Setback between attached structures and from peripheral lot lines, 10’ setback between detached structures Parking complies with Article VIII of Zoning Ordinance Conservation Resources Areas identified (COD) Approximate location of 404 Wetlands & Section 10 Wetlands Street Cross Section with typical marl and asphalt depths Within area of proposed thoroughfare (show location if applicable) NEW HANOVER COUNTY PLANNING & INSPECTIONS DEPARTMENT PERFORMANCE DEVELOPMENT CHECKLIST & DENSITY CALCULATIONS 230 Government Center Dr Suite 110 Wilmington, NC 28403 910-798-7165 phone 910-798-7053 fax www.nhcgov.com Page 2 of 2 PRC 05/10 Tree retention and landscaping in accordance with Section 67 Private streets acceptable to County Engineer or public streets acceptable to NCDOT Total acres submerged land, plat area per dwelling unit & acreage of open space Hurricane evacuation plan (if applicable) Unduplicated Development and street names Names and locations of adjoining subdivisions, streets, adjacent property owners Roadway cross-section and drainage design Lot lines, lot numbers, and setback lines Block lengths greater than 400’ but less than 1000’, cul-de-sacs less than 500’ Street jogs are no less than 200’ Street inter-connectivity, (Index 1.4 or greater) Significant tree survey Traffic Impact Analysis (TIA) Water/ Sewer Capacity Letters Street lights Fire hydrant and locations Sidewalks & Pedestrian easements Double frontage lots shall be avoided DENSITY CALCULATIONS: Gross Tract Acreage: _________________________ Less: Area in lakes, ponds, or marshes. Area in Class IV soils as confirmed by Soils Conservation Service. (In lieu of Subtracting Dorovan, Johnston and/or Pamilco soils the developer may choose to preserve 100% of such areas as conservation space. -_________________________ Maximum Density for applicable zone Circle: R-10=3.3, R-15=2.5, R-20=1.9 Net Tract Acreage _________________________ Equal Number of units permitted on site Total Number Units Permitted:_______________________(Net Acreage times Applicable zone factor) Staff Use Only: ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ 41 4039 38373635 34 23 33 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 24 25 26 27 28 29 30 31 32 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 41 4039 38373635 34 23 33 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 24 25 26 27 28 29 30 31 32 44 45 46 47 48 49 50 51 52 53