2022.0286.01_ILM_New Parking Lot Project PlansNOT RELEASED FOR CONSTRUCTION
NEW PARKING LOT PROJECT
WILMINGTON INTERNATIONAL AIRPORT (ILM)
WILMINGTON, NORTH CAROLINA
AUGUST 2023
LOCATION MAP
NOT TO SCALE
VICINITY MAP
NOT TO SCALE
AIRPORT LOCATION
PROJECT SITE
ENGINEERS & PLANNERS
AVCON, INC.
www.avconinc.com
6230 CAROLINA BEACH ROADWILMINGTON, NC 28412 OFFICE:(910) 685-7113
G
.
MARTIN W Y N N JR.
G-01
SHEET INDEX AND
QUANTITIES
J.C.W.
J.C.W.
QUANTITIES
ITEM
NO.SPEC NO.DESCRIPTION UNIT QUANTITY
1 NCDOT 235 EMBANKMENT IN PLACE CY 14,900
2 NCDOT 235 UNSUITABLE EXCAVATION CY 6,200
3 NCDOT 250 REMOVAL OF EXISTING ASPHALT PAVEMENT SY 40
4 NCDOT 260 PROOF ROLLING SY 25,500
5 NCDOT 305 15" REINFORCED CONCRETE PIPE, CLASS III LF 350
6 NCDOT 305 18" REINFORCED CONCRETE PIPE, CLASS III LF 360
7 NCDOT 305 24" REINFORCED CONCRETE PIPE, CLASS III LF 740
8 NCDOT 305 30" REINFORCED CONCRETE PIPE, CLASS III LF 470
9 NCDOT 305 42" REINFORCED CONCRETE PIPE, CLASS III LF 50
10 NCDOT 340 PIPE REMOVAL LF 250
11 NCDOT 402 REMOVAL OF EXISTING STRUCTURE EA 4
12 NCDOT 500 FINE GRADING LS 1
13 NCDOT 520 AGGREGATE BASE COURSE (6")CY 4,500
14 NCDOT 600 PRIME COAT GAL 7,600
15 NCDOT 610 ASPHALT CONCRETE SURFACE COURSE, TYPE S9.5B TON 4,400
16 NCDOT 800 MOBILIZATION LS 1
17 NCDOT 801 SURVEY AND STAKEOUT LS 1
18 NCDOT 802 DISPOSAL OF WASTE AND DEBRIS LS 1
19 NCDOT 840 CATCH BASIN EA 18
20 NCDOT 840 DROP INLET EA 1
21 NCDOT 840 MANHOLE EA 1
22 NCDOT 840 24" FLARED END SECTION EA 1
23 NCDOT 840 30" FLARED END SECTION EA 1
24 NCDOT 840 42" FLARED END SECTION EA 1
25 NCDOT 846 6" CONCRETE CURB AND GUTTER LF 3,200
26 NCDOT 846 6" CONCRETE CURB LF 3,700
27 NCDOT 848 CURB RAMPS EA 9
28 NCDOT 1089 TRAFFIC CONTROL LS 1
29 NCDOT 1205 PAINT PAVEMENT MARKING LINES, 4" WHITE LF 13,400
30 NCDOT 1205 PAINT PAVEMENT MARKING LINES, 24" WHITE LF 280
31 NCDOT 1205 PAINT PAVEMENT MARKING LINES, 4" YELLOW LF 1,100
32 NCDOT 1205 PAVEMENT MARKING SYMBOLS, WHITE EA 19
33 NCDOT 1631 MATTING FOR EROSION CONTROL SY 9,700
34 NCDOT 1660 SEEDING AND MULCHING AC 2
35 C-102 SILT FENCE LF 3,300
36 C-102 DIVERSION DITCH LF 450
37 C-102 BLOCK AND GRAVEL INLET PROTECTION EA 20
38 C-102 CONSTRUCTION ENTRANCE EA 1
39 C-102 RIPRAP CLASS B CY 20
40 C-102 COMPOST STOCK LF 400
41 S-910 PARKING CONTROL SYSTEM INFRASTRUCTURE LS 1
42 S-910 WAYFINDING/SIGNAGE EA 7
43 S-910 HANDICAP SIGNAGE PARKING LOT EA 12
44 S-910 RELOCATE EXISTING WAYFINDING/SIGNAGE EA 4
45 S-910 AREA LIGHTING POLE, MAST, FOUNDATION (DUAL FIXTURE)EA 22
46 S-910 AREA LIGHTING POLE, MAST, FOUNDATION (SINGLE FIXTURE)EA 5
47 S-910 RELOCATE EXISTING AREA LIGHTING POLE EA 1
48 S-910 AREA LIGHTING CONDUIT LF 3,400
49 S-910 AREA LIGHTING CIRCUIT LS 1
50 S-910 WOOD POST FENCE WITH STAINLESS STEEL CABLE LF 2,350
51 S-910 ASPHALT SIDEWALK SY 600
52 S-910 LANDSCAPING LS 1
53 ITEM OWNER'S $200,000 CONTINGENCY LS 1
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
N
D
E
X
A
N
D
Q
U
A
N
T
I
T
I
E
S
.
D
W
G
6
/
1
3
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
Sheet List Table
Sheet Number Sheet Title
G-00 COVER SHEET
G-01 SHEET INDEX AND QUANTITIES
G-02 GENERAL NOTES AND LEGEND
G-03 PROJECT LAYOUT, HAUL ROUTE AND STAGING AREA
G-04 SURVEY CONTROL PLAN
G-05 BORING LAYOUT
G-06 BORING LOGS
C-01 EXISTING CONDITIONS
C-02 DEMOLITION PLAN
C-03 GEOMETRIC PLAN
C-04 GRADING AND DRAINAGE NOTES
C-05 GRADING PLAN
C-06 ENTRANCE ROAD PROFILE
C-07 STORMWATER DETAILS (SHEET 1 OF 2)
C-08 STORMWATER DETAILS (SHEET 2 OF 2)
C-09 STORM DRAINAGE SUMMARY
C-10 STORM DRAINAGE PROFILES (SHEET 1 OF 2)
C-11 STORM DRAINAGE PROFILES (SHEET 2 OF 2)
C-12 PAVING NOTES AND DETAILS
C-13 PAVING PLAN
C-14 SIDEWALK AND ISLAND DETAILS
C-15 MARKING NOTES AND DETAILS
C-16 MARKING PLAN - PARKING LOT
C-17 FENCING NOTES AND DETAILS
C-18 FENCING PLAN
C-19 GATE ENTRANCE, EXIT AND BOLLARD DETAILS (SHEET 1 OF 4)
C-19A GATE ENTRANCE, EXIT AND BOLLARDS DETAILS (SHEET 2 OF 4)
C-19B GATE ENTRANCE, EXIT AND BOLLARDS DETAILS (SHEET 3 OF 4)
C-19C GATE ENTRANCE, EXIT AND BOLLARDS DETAILS (SHEET 4 OF 4)
C-20 PARKING LOT SIGN PLAN
C-21 ELECTRICAL AND LIGHTING PLAN
C-22 ELECTRICAL AND LIGHTING DETAILS
EC-01 EROSION AND SEDIMENT CONTROL NOTES (SHEET 1 OF 3)
EC-02 EROSION AND SEDIMENT CONTROL NOTES (SHEET 2 OF 3)
EC-03 EROSION AND SEDIMENT CONTROL NOTES (SHEET 3 OF 3)
EC-04 EROSION AND SEDIMENT CONTROL PLAN - PHASE 1A
EC-05 EROSION AND SEDIMENT CONTROL PLAN - PHASE 1B
EC-06 EROSION AND SEDIMENT CONTROL PLAN - PHASE 1C
EC-07 EROSION AND SEDIMENT CONTROL PLAN - PHASE 1D
EC-08 EROSION AND SEDIMENT CONTROL PLAN - PHASE 1E
EC-09 EROSION AND SEDIMENT CONTROL PLAN - PHASE 1F
EC-10 EROSION AND SEDIMENT CONTROL PLAN - PHASE 1G
EC-11 EROSION AND SEDIMENT CONTROL PLAN - PHASE 2
EC-12 EROSION AND SEDIMENT CONTROL DETAILS (SHEET 1 OF 2)
EC-13 EROSION AND SEDIMENT CONTROL DETAILS (SHEET 2 OF 2)
SW-01 OVERALL STORMWATER SUMMARY
SW-02 PROPOSED DRAINAGE DIVIDES
L-01 OVERALL LANDSCAPE PLAN
DEDUCT BID ITEMS
ITEM
NO SPEC NO.DESCRIPTION UNIT QUANTITY
1 NCDOT 610 ASPHALT CONCRETE SURFACE COURSE, TYPE S9.5B TON 4,400
2 NCDOT 846 6" CONCRETE CURB AND GUTTER LF 3,200
3 NCDOT 846 6" CONCRETE CURB LF 3,700
BID ADDITIVE ITEMS
ITEM
NO SPEC NO.DESCRIPTION UNIT QUANTITY
1 NCDOT 235 EMBANKMENT IN PLACE CY 6,100
LEGEND
DESCRIPTION EXISTING PROPOSED
SURVEY CONTROL POINT BENCHMARK N/A
SPOT ELEVATION
CONTOUR
FENCE LINE
UNDERGROUND ELECTRICAL
UNDERGROUND FIBER OPTIC CABLE
SANITARY SEWER MANHOLE
AIRPORT PROPERTY LINE N/A
EDGE OF PAVEMENT
BUILDING OR STRUCTURE
CONCRETE
RIP RAP
OBJECT TO BE DEMOLISHED N/A
PAVEMENT DEMOLITION N/A
GRAVEL REMOVAL N/A
PAVEMENT RECONSTRUCTION N/A
DRAINAGE PIPE
DROP INLET
HEADWALL / ENDWALL
FLARED END SECTION
ASPHALT PAVEMENT N/A
ACCESS ROAD PAVEMENT N/A
BORING TESTING LOCATIONS N/A
CONTRACTOR HAUL ROUTE N/A
CONSTRUCTION LIMITS N/A
CONTRACTOR'S STAGING OR STOCKPILE AREA N/A
WETLANDS N/A
TREES N/A
WOODLINE / VEGETATION N/A
BM-1
27
X X
30
X X
UGE UGE UGE
B-1
S S
UGE UGE UGE
S-25
FO FO FO FO FO FO
G-02
GENERAL NOTES
AND LEGEND
J.C.W.
J.C.W.
GENERAL NOTES
1. PRIOR TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL HAVE AN APPROVED CONSTRUCTION SCHEDULE WHICHSHALL BE IN ACCORDANCE WITH THE CONSTRUCTION PLANS AND SPECIFICATIONS. THE CONTRACTOR SHALL REVISE ANDRESUBMIT THE SCHEDULE AS DIRECTED BY THE AIRPORT AND ENGINEER AND AS WORK PROGRESSES AND THE SCHEDULE IS
AFFECTED.
2. THE CONTACT PERSON FOR THE WILMINGTON INTERNATIONAL AIRPORT IS GRANSEUR DICK, DEPUTY AIRPORT DIRECTOR OF
OPERATIONS, FACILITIES AND MAINTENANCE, 910-341-4333 (X-1016).
3. CONTRACTOR'S SUPERINTENDENT SHALL BE ON THE CONSTRUCTION SITE AT ALL TIMES DURING WORKING HOURS WHILE JOBIS IN PROGRESS AND SHALL BE DESIGNATED AS THE RESPONSIBLE CONTRACTOR'S REPRESENTATIVE WHO SHALL BEAVAILABLE ON A 24-HOUR BASIS.
4. STOCKPILED MATERIAL SHALL BE CONSTRAINED IN A MANNER TO PREVENT MOVEMENT AS A RESULT OF WEATHER, WIND, OR
AIRCRAFT JET BLAST. MATERIALS SHALL BE STORED IN THE DESIGNATED CONTRACTOR'S STAGING AREA UNLESS OTHERWISE
DIRECTED BY THE AIRPORT AND ENGINEER.
5. BEFORE USING A CONSTRUCTION ACCESS POINT OR GATE, THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE
CONSTRUCTION ACCESS WITH THE AIRPORT. THE CONTRACTOR WILL RESTORE ALL PAVED AND GRASSED AREAS WITHIN THE
AIRPORT PROPERTY, OUTSIDE THE LIMITS OF CONSTRUCTION, WHICH ARE DISTURBED BY CONSTRUCTION ACTIVITY (ACCESS,HAUL, STAGING, ETC.) TO THEIR PRE-CONSTRUCTION CONDITION. NO DIRECT PAYMENT WILL BE MADE FOR THIS AS IT ISCONSIDERED A SUBSIDIARY OBLIGATION OF THE CONTRACTOR.
6. DURING HOURS OF RESTRICTED VISIBILITY OR DARKNESS, OPEN TRENCHES, EXCAVATIONS, AND STOCKPILED MATERIAL AT
THE CONSTRUCTION SITE SHALL BE PROMINENTLY MARKED WITH ORANGE FLAGS AND LIGHTED WITH FLASHING RED LIGHTS
UNITS (ACCEPTABLE TO THE AIRPORT).
7. CONTRACTOR'S CONSTRUCTION EQUIPMENT AND EMPLOYEE'S VEHICLES SHALL ONLY BE PARKED IN DESIGNATED AREAS
WITHIN THE CONTRACTOR'S STAGING AND STORAGE AREAS WHEN NOT IN USE, OR OR OUTSIDE OF ESTABLISHED HOURS OF
CONSTRUCTION.
8. ALL WASTE MATERIALS, CONSTRUCTION DEBRIS AND DEMOLITION MATERIALS SHALL BE DISPOSED OF OFF-SITE BY THECONTRACTOR OR AT AN ON-SITE LOCATION APPROVED BY THE AIRPORT.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD LOCATION AND VERIFICATION OF ALL CABLES AND UTILITIES BEFORE
CONSTRUCTION. DAMAGE TO ANY OF THESE UTILITIES SHALL BE REPAIRED IMMEDIATELY BY THE CONTRACTOR AT THE
CONTRACTORS EXPENSE IN THE MANNER ACCEPTABLE TO BOTH THE ENGINEER AND OWNER. DAMAGES INCURRED BY THE
AIRPORT, FAA, OR OTHERS DUE TO DAMAGES BY CONTRACTOR ARE ALSO SUBJECT TO MONETARY FINE BY THE AIRPORT.
10. ANY PERMITS REQUIRED FOR THE COMPLETION OF THIS PROJECT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
11. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODES AND BE CONSTRUCTED TO THE SAME.
UTILITY NOTES
1. CONTRACTOR SHALL REVIEW ALL UTILITIES WITH AIRPORT STAFF PRIOR TO BEGINNING WORK.
2. UTILITIES SHOWN ON THE PLANS ARE INFORMATIONAL PURPOSES ONLY. CONTRACTOR SHALL FIELD VERIFY ALL UTILITIES FOR
LOCATIONS PRIOR TO BEGINNING WORK.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD LOCATION AND VERIFICATION OF ALL UTILITIES AND CABLES. VERIFICATION
OF UTILITIES MUST BE BY MEANS OF HAND-DUG TEST HOLES PRIOR TO EXCAVATION. DAMAGE TO ANY OF THESE UTILITIES
SHALL BE REPAIRED IMMEDIATELY BY THE CONTRACTOR AT THE CONTRACTORS EXPENSE IN A MANNER ACCEPTABLE TO THE
AIRPORT. DAMAGES INCURRED BY THE AIRPORT, OR OTHERS DUE TO DAMAGES BY CONTRACTOR ARE ALSO SUBJECT TOMONETARY FINE BY THE AIRPORT
4. PROTECTION AND REPAIR OF EXISTING CABLES AND UTILITIES - ALL UNDERGROUND UTILITIES SHALL BE PROTECTED, ANDDAMAGES REPAIRED IMMEDIATELY AS SPECIFIED IN SPECIAL PROVISIONS.NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
G
E
N
E
R
A
L
N
O
T
E
S
.
D
W
G
4
/
1
9
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
5' SID
E
W
A
L
K
CURB LIN
E
CURB LINE
CURB LINE
CURB LINE
CURB LINE
CUR
B
L
I
N
E
CURB LINE
CONSTRUCTIONTRAILER
GRAVELPARKING
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DO
L
A
N
D
R
I
V
E
AVIATION DRIVE
CONTRACTOR
STAGING AREA
CONTRACTORACESS POINT
PROJECT LIMITS
GARD
N
E
R
R
O
A
D
HALL DRIVE
HAL
L
D
R
I
V
E
T
R
A
S
K
D
R
I
V
E
GA
R
D
N
E
R
R
O
A
D
PRIMARY CONTRACTOR
HAUL ROUTE ACCESS
POINT
SECONDARY CONTRACTOR HAUL ROUTE
ACCESS POINT. CONSTRUCTION VEHICLES MAY
ENTER AIRPORT BOULEVARD TO ACCESS THE
CONSTRUCTION SITE, HOWEVER, THEY MUST
TURN ONTO GARDNER ROAD. CONSTRUCTIONVEHICLES ARE NOT PERMITTED TO GO IN FRONTOF AIRPORT TERMINAL AT ANY TIME.
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 10050 200
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
P
R
O
J
E
C
T
L
A
Y
O
U
T
.
D
W
G
7
/
3
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
G-03
PROJECT LAYOUT,
HAUL ROUTE AND
STAGING AREA
ACCESS AND HAUL ROUTE NOTES
1. THE HAUL ROUTES TO BE USED FOR THIS PROJECT SHALL BE AS INDICATED ON THE DRAWINGS OR OTHERWISESPECIFICALLY AUTHORIZED BY THE AIRPORT. IN GENERAL, THE CONTRACTOR SHALL CONFINE EQUIPMENT AND HAULINGOPERATIONS TO THE AREAS UNDER CONSTRUCTION. DEBRIS SHALL BE CLEANED FROM THE ROADWAYS AND AIRPORT
PAVED SURFACES AS DIRECTED BY THE AIRPORT AND/OR ENGINEER. THE RUNWAY, TAXIWAYS, AND APRON SHALL BE KEPT
FREE OF DEBRIS AT ALL TIMES. OTHER PAVEMENTS SHALL BE CLEANED BY THE CONTRACTOR AS REQUIRED, USING POWER
BROOMS TO KEEP ALL ACCESS AND CONSTRUCTION AREAS CLEAR OF SOILS, FOD, OR OTHER DEBRIS.
2. THE ACCESS POINTS TO THE PROJECT SITE ARE SHOWN ON THE PLANS. THE AIRPORT RESERVES THE RIGHT TO CHANGE
HAUL ROUTE AND ACCESS POINTS AT ANY TIME.
3. THE CONTRACTOR SHALL RESTORE ALL TURFED AND PAVED AREAS USED FOR HAUL ROADS TO THEIR ORIGINAL CONDITION,INCLUDING THE ESTABLISHMENT OF TURF. ALL COST FOR CONSTRUCTING, REMOVING AND RESTORING OF HAUL ROADSREQUIRED FOR THE COMPLETION OF THE WORK SHALL BE BORNE BY THE CONTRACTOR AT NO COST TO THE AIRPORT.
4. THE CONTRACTOR SHALL NOT PERMIT ANY UNAUTHORIZED CONSTRUCTION PERSONNEL OR TRAFFIC ON THE SITE. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR TRAFFIC CONTROL TO AND FROM THE CONSTRUCTION AREAS WITHIN THE SITE.
THE CONTRACTOR IS RESPONSIBLE FOR THE IMMEDIATE CLEANUP OF ANY DEBRIS OR FOD DEPOSITED AT THE PROJECT
SITE AND ALONG ANY ROAD AS A RESULT OF HIS/HER CONSTRUCTION TRAFFIC.
5. ONLY RUBBER TIRED VEHICLES SHALL BE ALLOWED ON EXISTING AIRPORT PAVEMENT.
6. THE CONTRACTOR SHALL ESTABLISH AND MAINTAIN A LIST OF CONTRACTOR AND SUBCONTRACTOR EMPLOYEES ANDVEHICLES AUTHORIZED TO OPERATE ON THE SITE. AN UPDATED LIST SHALL BE PROVIDED TO ENGINEER WEEKLY.
7. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE OFF-SITE ROUTES (STATE HIGHWAYS, COUNTY ROADS
OR CITY STREETS), AND OBTAIN ANY REQUIRED PERMITS WITH THE APPROPRIATE AGENCY HAVING JURISDICTION OVER THE
AFFECTED ROUTE.
8. ALL CONTRACTOR VEHICLES AND TRAFFIC SHALL REMAIN WITHIN THE DESIGNATED CONSTRUCTION AREAS, STAGING
AREAS AND/OR HAUL ROUTES.
9. ALL CONTRACTOR VEHICLES SHALL DISPLAY IN FULL VIEW LOGOS CONSPICUOUSLY PLACED ON EACH SIDE OF THEVEHICLE. ALL VEHICLES OPERATING IN THE ACTIVE AIRSIDE OPERATION AREA (AOA) DURING HOURS OF LOW VISIBILITY ORDARKNESS SHALL BE EQUIPPED WITH A FLASHING AMBER DOME-TYPE LIGHT MOUNTED ON TOP OF THE VEHICLE, THEFLASHING LIGHT SHALL BE OF SUCH INTENSITY TO CONFORM TO AIRPORT CODES FOR MAINTENANCE AND EMERGENCY
VEHICLES.
10. THE CONTRACTOR SHALL PROVIDE PAINTED SIGNS TO DIRECT MATERIAL SUPPLIERS AND EMPLOYEES TO THE
CONSTRUCTION SITE. SIGN AT ENTRANCE GATE SHALL BE PROFESSIONALLY PAINTED 4'X8' AND READ "CONSTRUCTION
VEHICLES ONLY - NO VENDORS ALLOWED".
CONTRACTORS STOCKPILE NOTES
1. STOCKPILING LOCATIONS SHALL BE COORDINATED WITH THE AIRPORT AND/OR ENGINEER.
2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO LOCATE AND PLACE STOCKPILES IN A MANNER TO MINIMIZE IMPACTS TO
ADJACENT WORK. ANY IMPACTS TO ADJACENT WORK DUE TO THE LOCATION AND PLACEMENT OF A STOCKPILE SHALL BE
THE RESPONSIBILITY OF THE CONTRACTOR TO MITIGATE WITHOUT ADDITIONAL COST TO THE AIRPORT.
3. ANY STOCKPILE TO BE PLACED SHALL BE DONE SO IN A MANNER TO AVOID EROSION DUE TO WIND OR RAIN. ANY IMPACTSTO ADJACENT WORK DUE TO THE EROSION OF A STOCKPILE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TOMITIGATE WITHOUT ADDITIONAL COST TO THE AIRPORT.
4. MOISTURE FOR STOCKPILED MATERIAL SHALL BE CHECKED PERIODICALLY TO ENSURE THE MATERIAL IS NOT TAKING ON
EXCESS RAIN OR WATER WHILE THE MATERIAL IS BEING STOCKPILED. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO REMOVE ANY EXCESS MOISTURE FROM STOCKPILED MATERIAL CAUSED BY THE MANNER OR LOCATION IN
WHICH THE CONTRACTOR STOCKPILED THE MATERIAL.
5. ONCE STOCKPILES ARE REMOVED, THE AREA SHALL BE SEEDED AND VEGETATED ACCORDINGLY AT NO ADDITIONAL COST
TO THE AIRPORT.
CONTRACTOR STAGING AREA NOTES
1. THE EXACT LIMITS, LIGHTING, AND SECURITY REQUIREMENTS OF THE CONTRACTOR'S STAGING AREA SHALL BEESTABLISHED BY THE CONTRACTOR WITH THE APPROVAL OF THE AIRPORT AND ENGINEER IN THE AREAS GENERALLY ASSHOWN ON THE PLANS.
2. ANY AND ALL REQUIRED UTILITIES FOR THE CONTRACTOR'S OPERATIONS SHALL BE ARRANGED FOR AND PAID FOR BY THE
CONTRACTOR DIRECTLY.
3. UTILITY ARRANGEMENTS SHALL BE SUBJECT TO THE APPROVAL OF THE AIRPORT.
4. IF THE CONTRACTOR DISTURBS ANY AREA OUTSIDE OF PROJECT AREAS, THE CONTRACTOR SHALL REPAIR AT NO COST TO
THE AIRPORT. THIS SHALL INCLUDE GRADING, SEEDING AND MULCHING.
5. ALL CONTRACTOR'S STAGING AREAS SHALL BE MAINTAINED THROUGHOUT THE PROJECT AND BROUGHT TO ORIGINALCONDITIONS AT THE END OF PROJECT.
6. SILT FENCE MAY BE REQUIRED AT STAGING AREAS AS DIRECTED BY ENGINEER.
LEGEND
CONTRACTOR'S STAGING AREA
PROJECT LIMITS
HAUL ROUTE
5' S
I
D
E
W
A
L
K
CURB LINE
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
BM-2
BM-1
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 6030 120
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
S
U
R
V
E
Y
C
O
N
T
R
O
L
P
L
A
N
.
D
W
G
4
/
2
5
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
G-04
SURVEY CONTROL
PLAN
NOTES
1. EXISTING TOPOGRAPHIC SURVEY FROM HANOVERDESIGN SERVICES, P.A. DATED MAY AND JULY 2022.
2. COORDINATES BASED ON NC STATE PLANE
COORDINATE SYSTEM (NAD 83 NSRS 2011) AND
ELEVATIONS BASED ON NAVD 88.
3. EXISTING UTILITIES SHOWN ARE APPROXIMATE AND
SHOULD BE FIELD VERIFIED BY CONTRACTOR.
4. ALL DISTANCES ARE HORIZONTAL GROUNDMEASUREMENTS IN FEET AND DECIMALS THEREOFUNLESS OTHERWISE NOTED.
SURVEY CONTROL POINTS
POINT # DESCRIPTION NORTHING EASTING ELEVATION
BM-1 BASE 190,714.230' 2,327,653.870'27.60'
BM-2 PK 191,368.696' 2,328,865.000'28.477'
5' S
I
D
E
W
A
L
K
N: 190,931.39±
E: 2,328,511.26±
B-6
N: 190,749.08±
E: 2,328,234.45±
B-9
N: 191,126.42±
E: 2,328,642.69±
B-2
N: 190,891.00±
E: 2,328,006.40±
B-4
N: 190,845.50±
E: 2,328,745.34±
B-7
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 5025 100
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
B
O
R
I
N
G
L
A
Y
O
U
T
.
D
W
G
7
/
3
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
GEOTECHNICAL ENGINEERINGINFORMATION PROVIDED BY:
S&ME, INC.
3006 HALL WATERS DRIVE, SUITE 100
WILMINGTON, NORTH CAROLINA 28405
PHONE: 910-799-9945
SOURCE:GEOTECHNICAL ENGINEERING REPORTDATED: 06-24-2022
LEGEND
APPROXIMATE LOCATIONS OF SOIL
TEST BORINGS SOURCE:
S&ME, INC. DATED: JUNE 24, 2022
NOTE
SEE SHEET G-06 FOR BORING LOGS.
G-05
BORING LAYOUT
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
B
O
R
I
N
G
L
O
G
S
.
D
W
G
3
/
9
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
G-06
BORING LOGS
30
24
21
26
26
27
27 28
29
26
27
23
24
23
24
25
23
2
5
26
27
28
22 23 24 25
2021
23
2
4
2
5
2
7
28
29
26
27
18
19
20
21
22
23
24
GAS
GAS
GAS
GAS
GAS
5' S
I
D
E
W
A
L
K
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
EXISTING
ELECTRIC BOX
EXISTING
CONCRETE
HEADWALL
EXISTING
SWALE
EXISTING 72" RCP
STORM SEWER
EXISTING 48" RCP
STORM SEWER
EXISTING INLET
EXISTING SANITARY
MANHOLE.
EXISTING INLET
EXISTING
MANHOLE
EXISTING INLET
EXISTING 42" RCP
STORM SEWER
EXISTING
SIGN
EXISTING
LIGHTPOLE
PROPOSED
PROJECT LIMITS
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 5025 100
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
E
X
I
S
T
I
N
G
C
O
N
D
I
T
I
O
N
S
.
D
W
G
7
/
3
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-01
EXISTING
CONDITIONS
LEGEND
PROPOSED PROJECT LIMITS
GAS
GAS
GAS
GAS
GAS
5' S
I
D
E
W
A
L
K
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
REMOVE
APPROXIMATELY 190 LF
OF 24" RCP
REMOVE SANITARY
SEWER MANHOLE
REMOVE EXISTING
INLET
REMOVE AND PROTECT
EXISTING SIGN. TO BE
RELOCATED.
REMOVE AND PROTECT
EXISTING LIGHT POLE.
TO BE RELOCATED
REMOVE AND PROTECT
EXISTING SIGN. TO BE
RELOCATED.
REMOVE
APPROXIMATELY 17 LF
OF 24" RCP
PROPOSED
PROJECT LIMITS
REMOVE EXISTINGINLET
REMOVE
APPROXIMATELY 27 SY
OF PAVEMENT
REMOVE EXISTING
ENDWALL
REMOVE
APPROXIMATELY 37 LF
OF 42" RCP
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 5025 100
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
D
E
M
O
L
I
T
I
O
N
P
L
A
N
.
D
W
G
7
/
3
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-02
DEMOLITION PLAN
DEMOLITION NOTES
1. CONTRACTOR SHALL PROTECT ALL EXISTING ITEMS INCLUDING, BUT NOT LIMITED TORUNWAY IN-PAVEMENT ELECTRICAL, CABLE LINES, DRAINAGE PIPES, AND STRUCTURES, ETC.
2. ANY DAMAGE TO EXISTING ITEMS SHALL BE REPAIRED IMMEDIATELY AT THE EXPENSE OFTHE CONTRACTOR. IF ITEMS CANNOT BE REPAIRED, THE CONTRACTOR SHALL REPLACE
ACCORDINGLY AT NO EXPENSE TO THE AIRPORT.
3. UTILITY LOCATIONS WILL NEED TO BE FIELD VERIFIED BY THE CONTRACTOR BOTH IN
LOCATION AND IN DEPTH PRIOR TO BEGINNING CONSTRUCTION. UTILITY LOCATIONS SHALL
BE KEPT FRESH BY CONTRACTOR THROUGHOUT DURATION OF PROJECT AT NO ADDITIONAL
COST.
4. CONTRACTOR SHALL REMOVE ALL MILLINGS, WASTE MATERIAL, AND DEBRIS OFF SITE IN APROPERLY PERMITTED LOCATION UNLESS OTHERWISE DIRECTED BY THE AIRPORT AND/ORTHE ENGINEER.
5. ALL DISTURBED AREAS RELATED TO REMOVAL EFFORTS SHALL BE SEEDED AND MULCHED
PER PLANS AND SPECIFICATIONS.
6. IN AREAS WHERE THE EXISTING PAVEMENT IS TO BE REMOVED, THE SAWCUT SHALL BE
STRAIGHT AND VERTICAL. ONCE THE PAVEMENT HAS BEEN REMOVED, THE CONTRACTOR
SHALL USE EXTREME CARE TO PROTECT THE EXPOSED PAVEMENT EDGE.
7. IN AREAS OF EXISTING PAVEMENT REMOVAL, THE CONTRACTOR SHALL MAINTAIN POSITIVEDRAINAGE AT ALL TIMES. ANY ADDITIONAL GRADING REQUIRED TO MAINTAIN POSITIVEDRAINAGE SHALL BE COMPLETED BY THE CONTRACTOR AS INCIDENTAL WORK FOR THE
PROJECT.
8. SEE SHEET G-05 FOR BORING LOCATIONS. SEE SHEET G-06 FOR BORING LOGS.
LEGEND
REMOVAL OF STRUCTURE
PAVEMENT DEMOLITION
GAS
GAS
GAS
GAS
GAS
5' S
I
D
E
W
A
L
K
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
N: 191,076.17
E: 2,328,740.17 N: 191,052.06E: 2,328,762.02
N: 190,997.68
E: 2,328,701.99
N: 190,986.26E: 2,328,689.39
N: 190,961.84E: 2,328,856.38
N: 190,455.88E: 2,328,261.61
N: 190,383.32E: 2,328,031.18
N: 190,527.73E: 2,328,183.19
N: 190,585.46
E: 2,328,246.93
N: 190,596.88E: 2,328,259.53
N: 190,672.74
E: 2,328,343.28
N: 190,684.15
E: 2,328,355.88
N: 190,747.93E: 2,328,426.28
N: 190,784.19
E: 2,328,466.31
N: 190,854.01
E: 2,328,543.38
N: 190,865.42E: 2,328,555.98
N: 190,923.16
E: 2,328,619.72
N: 190,934.57E: 2,328,632.32
N: 190,435.78
E: 2,328,182.71
R
5
'
5'
5'
44'
N: 190,490.46E: 2,328,229.94
N: 190,671.79E: 2,328,430.11
34'
N: 190,748.21
E: 2,328,499.57
N: 190,442.14
E: 2,328,102.37
SEE SHEET C-19 FOR
INFORMATIONREGARDING GATEENTRANCE AND EXIT.
22'
N: 190,413.48E: 2,328,111.14
24'
24'
N: 190,782.85E: 2,328,478.98
5'
N: 190,616.62
E: 2,328,618.60
N: 190,613.70E: 2,328,614.52
N: 190,638.26E: 2,328,599.94
N: 190,635.26E: 2,328,595.93
N: 190,685.90
E: 2,328,560.18
N: 190,682.86E: 2,328,556.21
R
5
'
R5'R5'
R7'
R2'
R4
'
R5'
R
5
'
R5
'
R5'
R5'
R5
'
R5
'
R5'
R
5
'
R5'
R
5
'
R5'
R
5
'
R5'R5'
R
5
'
R
5
'
R5'
R5'
R5
'
R
5
'
R5'R5'
R
5
'
R
5
'
R5'
R
5
'
R5'
R
5
'
R5'R
5
'
R
5
'
R5'R
5
'
R5'
R
5
'
R5'
R
5
'
R
5
'
R5'R5'
R
5
'
R5'
R
5
'
R5'
R5'
R15'
R
1
5
'
R
5
'
R5'
R
5
'
R5'
R
5
'
R5'
R
5
'
R5'
R
5
'
R5'
R
5
'
R5'
R5'
R
5
'
R
5
'
R5'
R
5
'
R5'R
5
'
R5'
R5
'
R5'
R5'
R
5
'
R
5
'
R5'
R
5
'
R5'R
5
'
R5'
R
5
'
R5'
R5'
R
5
'
R15'R50'
R25'
N: 190,712.96
E: 2,328,460.66
N: 190,773.40
E: 2,328,476.75
N: 190,966.68
E: 2,328,870.30
26'
29'
24'
24'
N: 190,712.08E: 2,327,945.82
N: 191,137.53E: 2,328,415.49
24'
24'
R5
'
R5'
R5
'
R5'
R5
'
R5'
R5
'
R5'R
5
'
R5'
R5
'
R5'
R5
'
R5'
R5
'
24'
24'
24'
N: 191,061.96
E: 2,328,367.82
N: 191,074.72
E: 2,328,381.90
24'
24'
24'
24'
24'
N: 190,897.44E: 2,328,186.20
N: 190,884.68
E: 2,328,172.11
24'
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 5025 100
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
G
E
O
M
E
T
R
I
C
P
L
A
N
.
D
W
G
7
/
3
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-03
GEOMETRIC PLAN
LEGEND
PROPOSED ASPHALT PAVEMENT
PROPOSED ASPHALT SIDEWALK
NOTES
1. INFORMATION REGARDING THE MARKING CAN BEFOUND ON SHEETS C-16.
2. INFORMATION REGARDING THE REQUIRED SIGNAGE
FOR THE PARKING LOT CAN BE FOUND ON SHEET
C-20.
3. INFORMATION REGARDING THE ELECTRICAL AND
LIGHTING FOR THE PARKING LOT CAN BE FOUND ONSHEET C-21.
4. NORTHING AND EASTING CALLOUTS ARE POINTING
TO THE EDGE OF THE ASPHALT PAVING LIMITS.
C-04
GRADING AND
DRAINAGE NOTES
J.C.W.
J.C.W.
DEWATERING NOTES
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DEWATERING OF THE PROJECT SITE TO THE APPROPRIATE DRAINAGE AND SEDIMENT ANDEROSION CONTROL MEASURES. THE DEWATERING OF A PROJECT AREA ACROSS AN ADJACENT AREA, EITHER WITHIN OR OUTSIDE THEPROJECT LIMITS, SHALL BE DONE SUCH THAT IT CAUSES NO DAMAGE TO ANY OF THE AREAS IMPACTED. ANY DAMAGE CAUSES BY THE
CONTRACTORS DEWATERING, ONSITE OR OFFSITE, SHALL BE REPAIRED AT NO COST TO THE OWNER.
2. DEWATERING OF THE SITE, EXCAVATIONS, TRENCHES, EMBANKMENT, EXISTING AND/OR PROPOSED PAVEMENT BOX, AND ALL OTHER
AREAS OF CONSTRUCTION REQUIRED FOR THE COMPLETION OF THE PROJECT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.ALONG WITH THE TEMPORARY AND PERMANENT MEASURES SHOWN ON THE PLAN, THE CONTRACTOR SHALL SUBMIT PROPOSED METHODSAND A DETAILED DEWATERING PLAN TO THE ENGINEER FOR REVIEW AND APPROVAL. DEWATERING PLAN SHALL BE SUBMITTED PRIOR TO
START OF GRADING OPERATIONS. THE METHODS AND PLAN SHALL INDICATE HOW THE CONTRACTOR WILL HANDLE THE DEWATERING OF
SITE THROUGH ALL PHASES OF THE PROJECT. ANY DAMAGES CAUSED BY THE FAILURE OF THE CONTRACTOR TO SUBMIT OR
ADEQUATELY MAINTAIN A DEWATERING PLAN SHALL BE PAID FOR SOLELY BY THE CONTRACTOR. FAILURE TO SUBMIT METHODS AND A
DEWATERING PLAN DOES NOT ALLEVIATE THE CONTRACTOR TO THE REQUIREMENTS HEREIN. THE DEWATERING METHODS AND PLANSHALL ADDRESS, AT A MINIMUM, THE FOLLOWING REQUIREMENTS:
A. SURFACE WATER AND SUBSURFACE OR GROUND WATER SHALL BE PREVENTED FROM FLOWING INTO EXCAVATIONS AND FROM
FLOODING THE PROJECT SITE AND SURROUNDING AREAS, INCLUDING AREAS DOWNSTREAM OF THE PROJECT AND OUTSIDE THE
PROJECT LIMITS. SURFACE WATER, PARTICULARLY IN UN-VEGETATED AREAS DURING CONSTRUCTION, SHOULD NOT BE ALLOWED TO
FLOW INTO UNPROTECTED STORM DRAINAGE MEASURES. THE CONTRACTOR SHALL IDENTIFY ANY STORM DRAINAGE THAT IT TO BEUSED AS PART OF THE DEWATERING PLAN. ANY DAMAGES CAUSED BY THE FAILURE OF THE CONTRACTOR TO SUBMIT OR ADEQUATELYMAINTAIN DEWATERING PLAN SHALL BE PAID FOR BY THE CONTRACTOR.
B. DO NOT ALLOW WATER TO ACCUMULATE IN EXCAVATIONS, INCLUDING THE EXISTING PAVEMENT REMOVAL AREAS. REMOVE WATER TO
PREVENT SOFTENING OF FOUNDATION SOILS, UNDERCUTTING OF FOOTINGS, AND SOIL CHANGES DETRIMENTAL TO THE STABILITY OF
SUBGRADES AND FOUNDATIONS. MAINTAIN GRADES SO THAT THE SURFACE IS WELL DRAINED. PROVIDE AND MAINTAIN PUMPS, WELLPOINTS, SUMPS, SUCTION AND DISCHARGE LINES, AND OTHER DEWATERING SYSTEM COMPONENTS NECESSARY TO CONVEY WATERAWAY FROM EXCAVATIONS. THE CONTRACTOR SHALL MAINTAIN ADEQUATE METHODS TO REMOVE WATER FROM THE SITE AT ALL
TIMES.
C. CONVEY WATER REMOVED FROM EXCAVATIONS AND DRAIN TO COLLECTING OR RUNOFF AREAS. ESTABLISH AND MAINTAIN
TEMPORARY DRAINAGE DITCHES, SWALES, AND OTHER DIVERSIONS TO PROTECT SLOPES AND STRUCTURES. DO NOT USE TRENCHEXCAVATIONS AS TEMPORARY DRAINAGE DITCHES. WATER REMOVED FROM EXCAVATIONS SHALL NOT BE ALLOWED TO FLOWUNCONTROLLED THROUGH THE SITE. THE DEWATERING PLAN SHALL IDENTIFY MEASURES TO BE USED TO HINDER EROSION DUE TO
THE DEWATERING OF AREAS.
GRADING AND DRAINAGE NOTES
1. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES. THE CONTRACTOR SHALL IMMEDIATELY REPORT TOENGINEER ANY DISCREPANCIES FOUND BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS AND SHALL WAIT FORINSTRUCTION PRIOR TO PROCEEDING.
2. IT IS THE INTENTION OF THE PROJECT TO TIE PROPOSED GRADING INTO EXISTING TOPOGRAPHY. IT SHALL BE UNDERSTOOD BY THECONTRACTOR THAT UNLESS OTHERWISE INDICATED, THE LAST PROPOSED CONTOUR SHOWN SHALL TIE INTO THE EXISTINGTOPOGRAPHY AT THE NEAREST EXISTING CONTOUR IN ORDER TO PROVIDE FOR POSITIVE DRAINAGE. THIS TIE IN SHALL BE A SMOOTHTRANSITION TO EXISTING TOPOGRAPHY. WORK COVERED UNDER THIS ITEM AND SLIGHT ADJUSTMENTS TO TIE IN LIMITS TO MEET THEREQUIREMENTS AND INTENTS OF THE PLANS SHALL BE INCIDENTAL TO THE GRADING OPERATIONS.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING EXISTING UTILITIES PRIOR TO COMMENCING WORK IN THATAREA, AND SHALL REPAIR ALL DAMAGE TO EXISTING UTILITIES THAT OCCUR DURING CONSTRUCTION. CONTRACTOR SHALL BLEND NEWEARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE.
4. TOPOGRAPHIC INFORMATION SHOWN IN THESE PLANS IS FROM EXISTING TOPOGRAPHIC SURVEYS FROM HANOVER DESIGNS, DATEDJULY 15, 2022.
5. PRIOR TO SETTING ANY CONSTRUCTION STAKES, THE CONTRACTOR SHALL FIRST VERIFY THE ACCURACY OF THE CONTROL POINTSESTABLISHED FOR THIS PROJECT. IF ERRORS OR DISCREPANCIES ARE DISCOVERED DURING THIS VERIFICATION PROCESS, THECONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING, EXPLAINING THE ISSUE IN DETAIL. SECONDLY, UPON COMPLETIONOF THIS VERIFICATION PROCESS, THE CONTRACTOR'S REGISTERED LAND SURVEYOR SHALL CERTIFY IN WRITING, THAT ALL CONTROLPOINTS ARE ACCEPTABLE AND ADEQUATE TO ALLOW THE CONTRACTOR'S CONSTRUCTION STAKING TO MEET THE ACCURACY
REQUIREMENTS OF THE SPECIFICATION.
6. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHOWN ARE APPROXIMATE AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BYTHE AIRPORT OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE
COMMENCING WORK.
7. EVERY EFFORT HAS BEEN MADE TO SHOW ALL EXISTING UTILITIES AND FACILITIES WITHIN THE PROJECT LIMITS. HOWEVER, IT IS THECONTRACTOR'S RESPONSIBILITY TO VERIFY AND LOCATE ALL UTILITIES WITHIN THE PROJECT AREA PRIOR TO BEGINNING ANYCONSTRUCTION OPERATIONS. THE CONTRACTOR SHALL ALSO VERIFY DEPTH OF THE UTILITIES AND FACILITIES PRIOR TO INSTALLINGANY PIPE OR STRUCTURES TO PREVENT ANY UTILITY CONFLICTS. ANY IMPACTS TO EXISTING UTILITIES SHALL BE COORDINATED BY THECONTRACTOR.
8. THE CONTRACTOR SHALL LOCATE AND PROTECT EXISTING UTILITIES AND FACILITIES FROM DAMAGE BY EQUIPMENT OR PERSONNEL. THECONTRACTOR SHALL CONTACT ALL UTILITY AND FACILITY AGENCIES, INCLUDING THE AIRPORT, FOR FIELD MARKING PRIOR TO BEGINNINGCONSTRUCTION OPERATIONS.
9. ANY UTILITIES OR FACILITIES DAMAGED BY THE CONTRACTOR'S OPERATIONS SHALL BE REPORTED TO THE AIRPORT AND ENGINEERIMMEDIATELY AND REPAIRED AS DIRECTED AT THE CONTRACTOR'S EXPENSE.
10. ALL UNPAVED AREAS DISTURBED BY GRADING OPERATION SHALL BE RE-VEGETATED. THE CONTRACTOR SHALL SOW GRASS ONDISTURBED AREAS IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS.
11. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL SHEETING, SHORING, BRACING, AND SPECIALEXCAVATION MEASURES REQUIRED TO MEET OSHA, FEDERAL, STATE, AND LOCAL REGULATIONS PURSUANT TO THE INSTALLATION OFTHE WORK INDICATED ON THESE DRAWINGS.
12. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS RESPONSIBILITY TOREPAIR AND/OR REPLACE THE EXISTING STRUCTURES AS NECESSARY TO RETURN THEM TO PRE-CONSTRUCTION CONDITIONS AT THECONTRACTORS EXPENSE. NO SEPARATE PAYMENT WILL BE MADE FOR THESE REPAIRS.
13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING POSITIVE DRAINAGE THROUGH THE SITE AND ACROSS THE PROJECT. THEPOSITIVE DRAINAGE INCLUDES DRAINAGE TO THE APPROPRIATE DRAINAGE STRUCTURES AND EROSION AND SEDIMENT CONTROLMEASURES.
14. THE CONTRACTOR SHALL MAINTAIN ALL SEDIMENT AND EROSION CONTROL MEASURES THROUGHOUT THE DURATION OF THE PROJECT.AT THE END OF THE PROJECT, THE CONTRACTOR SHALL REMOVE EROSION AND SEDIMENT CONTROL AS DIRECTED BY THE ENGINEER.
15. ALL EXCAVATION WASTE MATERIAL, CONSTRUCTION DEBRIS, AND DEMOLITION MATERIALS SHALL BE DISPOSED OF OFF-SITE BY THECONTRACTOR. ANY WASTE MATERIAL STOCK PILED ON-SITE SHALL BE COVERED AND/OR SECURED AT ALL TIME TO AVOID BLOWING ORBECOMING FOD.
16. IN THE CASE THE CONTRACTOR WILL BE REQUIRED TO WORK AT NIGHT, THE CONTRACTOR WILL NEED TO PROVIDE PROPER LIGHTINGFOR NIGHT WORK. LIGHTING SHALL BE SHIELDED AND POINTED DOWN TO AVOID INTERFERENCE WITH AIRCRAFT OPERATIONS.
17. CONTRACTOR'S SUPERINTENDENT SHALL BE ON THE CONSTRUCTION SITE AT ALL TIMES DURING WORKING HOURS WHILE THE PROJECTIS IN PROCESS, AND SHALL BE DESIGNATED THE RESPONSIBLE CONTRACTOR'S REPRESENTATIVE WHO SHALL BE AVAILABLE ON A24-HOUR BASIS. CONTRACTOR SHALL SUPPLY THE AIRPORT/ENGINEER A 24-HOUR CONTACT LIST WITH PHONE NUMBERS AT THEPRE-CONSTRUCTION MEETING AND UPDATE, AS NEEDED, THROUGH OUT THE CONTRACT.
18. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH APPLICABLE STANDARDS AND SPECIFICATIONS OF THE FAA, NEW HANOVERCOUNTY, AND THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION.
19. THE PROJECT PAY ITEMS ARE PROVIDED TO BE INCLUSIVE OF ALL WORK TO BE PERFORMED AS SHOWN IN THESE PLANS. ALL INCIDENTALWORK REQUIRED TO COMPLETE THE PROJECT SHALL BE INCLUDED IN THE COSTS OF THE PAY ITEMS.
20. ALL CONTRACTOR VEHICLES AND TRAFFIC SHALL REMAIN WITHIN THE DESIGNATED CONSTRUCTION AREAS, STAGING AREAS, OR HAULROUTES.
21. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING AND ACQUIRING ALL REQUIRED PERMITS (OTHER THAN STORM WATER ANDNCDEQ SEDIMENTATION AND EROSION CONTROL). COPIES SHALL BE SUBMITTED TO THE AIRPORT AND ENGINEER. COST FOR THESEPERMITS SHALL BE INCIDENTAL TO THE COST OF THE ASSOCIATED WORK.
22. ALL EXISTING GRASSED AREAS WHICH ARE DISTURBED AS PART OF THE CONTRACTOR'S ACCESS ROAD, STAGING AREA, AND HAULROUTES, SHALL BE RESTORED TO THEIR ORIGINAL CONDITION AFTER COMPLETION OF THE PROJECT. IN ADDITION, ALL EXISTING ROADS,THAT WILL BE USED AS THE CONTRACTOR'S HAUL ROUTE, SHALL BE MAINTAINED DURING CONSTRUCTION AND RESTORED TO THEIRPRE-CONSTRUCTION CONDITION. NO SEPARATE MEASUREMENT OR PAYMENT WILL BE MADE FOR THIS ITEM.
23. ALL DISTURBED AREAS WITHIN THE PROJECT LIMITS SHALL BE SEEDED PER THE PLANS AND SPECIFICATIONS.
24. AS AREAS OF THE GRADING ARE COMPLETED, THEY SHALL BE SEEDED/MULCHED IMMEDIATELY, WITHOUT DELAY. ALL ASSOCIATEDCOSTS FOR THIS WORK SHALL BE INCIDENTAL TO THE SEEDING/MULCHING UNIT PRICES.
25. BURNING WILL NOT BE ALLOWED ON AIRPORT PROPERTY.
26. CONTRACTOR STAGING AREA SHALL BE MAINTAINED BY CONTRACTOR.
27. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF COMPLETED AND ONGOING WORK. ANY DAMAGE TO COMPLETED ORONGOING WORK SHALL BE REPAIRED BY THE CONTRACTOR AT NO COST TO THE AIRPORT.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
G
R
A
D
I
N
G
A
N
D
D
R
A
I
N
A
G
E
N
O
T
E
S
A
N
D
D
E
T
A
I
L
S
.
D
W
G
4
/
2
0
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
30
24
21
26
26
27
27 28
29
26
27
23
24
23
24
25
23
2
5
26
27
28
22 23 24 25
2021
23
2
4
2
5
2
7
28
29
26
27
18
19
20
21
22
23
24
GAS
GAS
GAS
GAS
GAS
5' S
I
D
E
W
A
L
K
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
S-1
S-2
S-4
S-5
S-6
S-7
S-13
S-12
S-11
S-14
S-15
S-16
S-17
S-18
S-19
S-3
MH-1
S-8
MH-2
ADJUST TOP OF
MANHOLE TO
PROPOSED GRADE
28
28
27
26
26
25
25
29
25
26
27
28
24
21 22 23 24 25
29
27
30
292827
26 27 28
28
29
2
7
2524
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 5025 100
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
G
R
A
D
I
N
G
P
L
A
N
.
D
W
G
8
/
3
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-05
GRADING PLAN
LEGEND
PROPOSED PAVEMENT
PROPOSED ASPHALT SIDEWALK
DRAINAGE PIPE
TOTAL SPACES = 522 PARKING SPACES
2
4
25
2
6
22
23
24
25
20
2
1
23
24
25
B-9BORE
0+0
0
1+00
2+00 3+00 4+00 5+00 5+98
28
27
26
25
25 26 27
24
21
22
23
24
25
PIPE S-19 TO S-15
EXISTING 24" PIPE
PIPE S-18 TO S-17 PIPE S-5 TO S-4
EXISTING GROUND
PROPOSED GRADE
10
20
30
10
20
30
-0.50%0.53%
0.57%
GR
A
D
E
B
R
E
A
K
S
T
A
=
0
+
0
0
.
0
0
EL
E
V
=
2
4
.
9
8
1
GR
A
D
E
B
R
E
A
K
S
T
A
=
1
+
2
5
.
0
0
EL
E
V
=
2
4
.
3
6
0
GR
A
D
E
B
R
E
A
K
S
T
A
=
5
+
9
7
.
8
8
EL
E
V
=
2
7
.
0
4
0
0+00
24
.
9
8
23
.
6
9
24
.
8
6
0+50
21
.
9
2
24
.
7
3
24
.
0
0
24
.
6
1
1+00
24
.
8
8
24
.
4
8
24
.
5
6
24
.
3
6
1+50
24
.
0
0
24
.
4
9
24
.
0
0
24
.
6
2
2+00
24
.
1
0
24
.
7
7
24
.
5
6
24
.
9
1
2+50
24
.
3
7
25
.
0
5
24
.
0
3
25
.
2
0
3+00
24
.
0
0
25
.
3
4
24
.
0
0
25
.
4
8
3+50
24
.
0
0
25
.
6
2
24
.
0
0
25
.
7
7
4+00
24
.
0
0
25
.
9
1
24
.
0
0
26
.
0
5
4+50
24
.
2
6
26
.
2
0
24
.
6
2
26
.
3
4
5+00
24
.
9
1
26
.
4
8
25
.
1
3
26
.
6
2
5+50
25
.
6
1
26
.
7
7
26
.
1
0
26
.
9
1
6+00
C-06
ENTRANCE ROAD
PROFILE
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
E
N
T
R
A
N
C
E
R
O
A
D
P
R
O
F
I
L
E
.
D
W
G
7
/
3
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
PLAN VIEW
PROFILE VIEW
50'
HORIZONTAL SCALE IN FEET
0' 25'100'
5'
VE
R
T
I
C
A
L
S
C
A
L
E
I
N
F
E
E
T
0'
10
'
GRAPHIC SCALE IN FEET
0 5025 100
No
r
t
h
C-07
STORMWATER DETAILS
(SHEET 1 OF 2)
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
S
T
O
R
M
W
A
T
E
R
D
E
T
A
I
L
S
.
D
W
G
4
/
2
7
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-08
STORMWATER DETAILS
(SHEET 2 OF 2)
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
S
T
O
R
M
W
A
T
E
R
D
E
T
A
I
L
S
.
D
W
G
4
/
2
7
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-09
STORM DRAINAGE
SUMMARY
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
S
T
O
R
M
D
R
A
I
N
S
U
M
M
A
R
Y
.
D
W
G
8
/
8
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
S-1 TO EXISTING MH
30” RCP, CLASS III
33.58 LF @ 0.50%
S-2 TO S-1
30” RCP, CLASS III
79.13 LF @ 0.50%
S-3 TO S-2
30” RCP, CLASS III
101 LF @ 0.50%
S-4 TO S-3
18” RCP, CLASS III
17.25 LF @ 0.50%
S-5 TO S-4
15" RCP, CLASS III
47.16 LF @ 0.50%
S-6 TO S-3
24" RCP, CLASS III
130.0 LF @ 0.50%
S-7 TO S-6
18" RCP, CLASS III
148.0 LF @ 0.50%
S-8 TO EXISTING MH
24" RCP, CLASS III
231.70 LF @ 0.50%
S-11 TO PROPOSED MH
24" RCP, CLASS III
19.22 LF @ 0.50%
S-12 TO S-11
18" RCP, CLASS III
103 LF @ 0.50%
S-13 TO S-12
15" RCP, CLASS III
94 LF @ 0.50%
S-14 TO EXISTING MH
42" RCP, CLASS III
43.90 LF @ 0.50%
S-16 TO S-15
24" RCP, CLASS III
19.71 LF @ 0.50%
S-17 TO S-16
15" RCP, CLASS III
31.14 LF @ 8.00%
S-18 TO S-17
15" RCP, CLASS III
27.17 LF @ 0.50%
S-19 TO S-15
18" RCP, CLASS III
62.67 LF @ 0.50%
STORM PIPE SUMMARY
S-1 INSTALL DROP INLET
N: 190,501.41
E: 2,328,108.13
GRATE ELEV.: 21.55'
30" INV. IN: 18.85'
30" INV. OUT: 18.75'
S-2 INSTALL CATCH BASIN
N: 190,527.90
E: 2,328,185.74
GRATE ELEV.: 24.67'
30" INV. IN: 19.94'
30" INV. OUT: 19.25'
S-3 INSTALL CATCH BASIN
N: 190,595.70
E: 2,328,260.59
GRATE ELEV.: 25.21'
18" INV. IN: 20.45' (NE)
24" INV. IN: 20.54' (N)
30" INV. OUT: 20.44'
S-4 INSTALL CATCH BASIN
N: 190,595.36
E: 2,328,277.84
GRATE ELEV.: 25.12'
15" INV. IN: 20.73'
18" INV. OUT: 20.63'
S-5 INSTALL CATCH BASIN
N: 190,560.40
E: 2,328,309.51
GRATE ELEV.: 25.12'
15" INV. OUT: 20.87'
S-6 INSTALL CATCH BASIN
N: 190,682.98
E: 2,328,356.94
GRATE ELEV.: 25.90'
18" INV IN: 22.20'
24" INV. OUT: 21.59'
S-7 INSTALL CATCH BASIN
N: 190,773.24
E: 2,328,474.20
GRATE ELEV.: 26.53'
18" INV. OUT: 22.94'
S-8 INSTALL DROP INLET
N: 190,709.12
E: 2,327,920.19
GRATE ELEV.: 21.13'
24" INV. OUT: 17.00'
S-11 INSTALL CATCH BASIN
N: 190,864.25
E: 2,328,557.05
GRATE ELEV.: 27.33'
18" INV. IN: 23.48'
24" INV. OUT: 23.25'
S-12 INSTALL CATCH BASIN
N: 190,933.40
E: 2,328,633.38
GRATE ELEV.: 27.84'
15" INV. IN: 24.09'
18" INV. OUT: 23.99'
S-13 INSTALL CATCH BASIN
N: 190,996.50
E: 2,328,703.05
GRATE ELEV. = 28.31'
15" INV. OUT: 24.56'
S-14 FLARED END SECTION
N: 190,942.11
E: 2,328,152.69
42" INV. IN: 17.75'
S-15 INSTALL MANHOLE
N: 190,408.52
E: 2,328,105.91
MANHOLE COVER = 23.34'
24" INV. IN: 16.30'
18" INV. IN: 21.68'
EX 24" INV OUT: 15.35'
S-16 INSTALL DROP INLET
N: 190,427.25
E: 2,328,112.04
GRATE ELEV: 20.40'
15" INV. IN: 17.01'
24" INV. OUT: 16.40'
S-17 INSTALL CATCH BASIN
N: 190,452.90
E: 2,328,129.71
GRATE ELEV.: 24.05'
15" INV. IN: 20.16'
15" INV. OUT: 19.50'
S-18 INSTALL CATCH BASIN
N: 190,478.48
E: 2,328,120.55
GRATE ELEV.: 24.05'
15" INV. OUT: 20.30'
S-19 FLARED END SECTION
N: 190,416.77
E: 2,328,043.71
18" INV. IN: 22.00'
STORM DRAINAGE SUMMARY
NOTES
1. NORTHINGS AND EASTINGS FOR CATCH BASINS, INLETS AND MANHOLESARE PROVIDED FOR THE CENTER OF THE STRUCTURE.
2. NORTHINGS AND EASTINGS FOR FLARED END SECTIONS ARE PROVIDED
FOR THE BACK CENTER OF STRUCTURE.
3. PIPE LENGTHS ARE PROVIDED FROM CENTER OF STRUCTURE TO CENTER
OF STRUCTURE.
4. CONTRACTOR SHALL SURVEY AND FIELD VERIFY ALL EXISTING INVERT
ELEVATIONS TO ENSURE PROPER TIE-IN TO EXISTING PIPES PRIOR TOCASTING OF NEW STRUCTURES.
10
20
30
10
20
30
0+00
24
.
0
0
24
.
0
0
24
.
0
0
24
.
0
0
0+50
24
.
0
0
24
.
0
0
1+00
S-5 TO S-4 TO S-3
S-
5
G
R
A
T
E
E
L
E
V
.
=
2
5
.
1
2
'
15
"
I
N
V
.
O
U
T
=
2
0
.
8
7
'
S-
4
G
R
A
T
E
E
L
E
V
.
=
2
5
.
1
2
'
15
"
I
N
V
.
I
N
=
2
0
.
7
3
'
18
"
I
N
V
.
O
U
T
=
2
0
.
6
3
'
47.16 LF OF15" RCP @ 0.50%
S-
3
G
R
A
T
E
E
L
E
V
.
=
2
5
.
2
1
'
18
"
I
N
V
.
I
N
=
2
0
.
4
5
'
(
N
E
)
24
"
I
N
V
.
I
N
=
2
0
.
9
5
'
(
E
)
30
"
I
N
V
.
O
U
T
=
2
0
.
4
4
'
17.25 LF OF
18" RCP @ 0.50%
EXISTINGGROUND
PROPOSED
GRADE
S-7 TO S-6 TO S-3 TO S-2 TO TO S-1 TO MH-1
10
20
30
10
20
30
0+00
26
.
7
3
26
.
7
3
26
.
3
8
26
.
3
8
0+50
26
.
0
0
26
.
0
0
25
.
8
3
25
.
8
3
1+00
25
.
3
3
25
.
3
3
25
.
0
1
25
.
0
1
1+50
24
.
6
9
24
.
6
9
24
.
3
6
24
.
3
6
2+00
24
.
1
8
24
.
1
8
24
.
0
0
24
.
0
0
2+50
24
.
0
0
24
.
0
0
24
.
0
0
24
.
0
0
3+00
24
.
0
0
24
.
0
0
24
.
0
0
24
.
0
0
3+50
24
.
0
0
24
.
0
0
24
.
0
0
24
.
0
0
4+00
24
.
0
0
24
.
0
0
24
.
1
2
24
.
1
2
4+50
24
.
3
1
24
.
3
1
24
.
2
9
24
.
2
9
5+00
24
.
0
7
24
.
0
7
5+50
130 LF OF 24" RCP @ 0.50%
S-
6
G
R
A
T
E
E
L
E
V
.
=
2
5
.
9
0
'
18
"
I
N
V
.
I
N
=
2
2
.
2
0
'
24
"
I
N
V
.
O
U
T
=
2
1
.
5
9
'
S-
7
G
R
A
T
E
E
L
E
V
.
=
2
6
.
5
3
'
18
"
I
N
V
.
O
U
T
=
2
2
.
9
4
'
148 LF OF 18" RCP @ 0.50%
EXISTING GROUND
PROPOSEDGRADE
101 LF OF 30"
RCP @ 0.50%
S-
2
G
R
A
T
E
B
A
S
I
N
E
L
E
V
.
=
2
4
.
6
7
'
30
"
I
N
V
.
I
N
=
1
9
.
9
4
'
30
"
I
N
V
.
O
U
T
=
1
9
.
2
5
'
S-
3
G
R
A
T
E
E
L
E
V
.
=
2
5
.
2
1
'
24
"
I
N
V
.
I
N
=
2
0
.
9
5
'
(
N
E
)
18
"
I
N
V
.
I
N
=
2
0
.
5
4
'
(
E
)
30
"
I
N
V
.
O
U
T
=
2
0
.
4
4
'
S-
1
G
R
A
T
E
B
A
S
I
N
E
L
E
V
.
=
2
1
.
5
5
'
30
"
I
N
V
.
I
N
=
1
6
.
9
9
'
30
"
I
N
V
.
O
U
T
=
1
6
.
8
0
'
MH
-
1
A
D
J
U
S
T
E
D
M
A
N
H
O
L
E
E
L
E
V
.
=
2
3
.
6
4
'
30
"
I
N
V
.
I
N
=
1
6
.
5
5
'
72
"
I
N
V
.
O
U
T
=
1
2
.
2
2
'
82 LF OF
3
0
"
RCP @ 2
.
7
6
%
49.48 LF OF30" RCP @ 0.50%
10
20
30
10
20
30
0+00
28
.
4
1
28
.
4
1
28
.
2
5
28
.
2
5
0+50
28
.
0
0
28
.
0
0
27
.
8
3
27
.
8
3
1+00
27
.
5
8
27
.
5
8
27
.
4
2
27
.
4
2
1+50
27
.
3
0
27
.
3
0
27
.
0
0
27
.
0
0
2+00
27
.
1
5
27
.
1
5
2+50
S-13 TO S-12 TO S-11 TO MH-2
S-
1
3
G
R
A
T
E
E
L
E
V
.
=
2
8
.
3
1
'
15
"
I
N
V
.
O
U
T
=
2
4
.
5
6
S-
1
2
G
R
A
T
E
E
L
E
V
.
=
2
7
.
8
4
'
15
"
I
N
V
.
I
N
=
2
4
.
0
9
'
18
"
I
N
V
.
O
U
T
=
2
3
.
9
9
'
S-
1
1
G
R
A
T
E
E
L
E
V
.
=
2
7
.
3
3
'
18
"
I
N
V
.
I
N
=
2
3
.
4
8
'
24
"
I
N
V
.
O
U
T
=
2
3
.
2
5
'
19.22 LF OF
24" RCP @ 0.50%
94 LF OF 15" RCP @ 0.50%103 LF OF 18" RCP @ 0.50%
MH
-
2
M
A
N
H
O
L
E
E
L
E
V
.
=
2
7
.
3
3
'
24
"
I
N
V
.
I
N
=
2
3
.
1
5
'
C-10
STORM
DRAINAGE
PROFILES
(SHEET 1 OF 2)
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
S
T
O
R
M
P
R
O
F
I
L
E
S
.
D
W
G
8
/
8
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
50'
HORIZONTAL SCALE IN FEET
0' 25'100'
5'
VE
R
T
I
C
A
L
S
C
A
L
E
I
N
F
E
E
T
0'
10
'
S-14 TO EX. 42" RCP
10
20
30
10
20
30
0+00
18
.
2
4
18
.
2
4
25
.
0
0
25
.
0
0
0+50
25
.
0
0
25
.
0
0
25
.
0
0
25
.
0
0
1+00
25
.
0
0
25
.
0
0
25
.
0
0
25
.
0
0
1+50
25
.
0
0
25
.
0
0
25
.
0
0
25
.
0
0
2+00
24
.
9
4
24
.
9
4
24
.
6
9
24
.
6
9
2+50
24
.
6
2
24
.
6
2
24
.
0
2
24
.
0
2
3+00
24
.
0
0
24
.
0
0
24
.
0
0
24
.
0
0
3+50
S-
1
4
F
L
A
R
E
D
E
N
D
S
E
C
T
I
O
N
42
"
I
N
V
.
I
N
=
1
7
.
7
5
'
43.90 LF OF42" RCP @ 0.50%
EXISTING GROUND
EX
I
S
T
I
N
G
I
N
L
E
T
E
L
E
V
.
=
2
5
.
0
0
'
42
"
I
N
V
.
I
N
=
1
7
.
5
3
'
42
"
I
N
V
,
O
U
T
=
1
5
.
6
1
'
10
20
30
10
20
30
0+00
24
.
6
1
24
.
6
1
24
.
3
1
24
.
3
1
0+50
22
.
0
3
22
.
0
3
22
.
5
5
22
.
5
5
1+00
22
.
4
8
22
.
4
8
21
.
8
7
21
.
8
7
1+50
S-18 TO S-17 TO S-16 TO S-15 TO S-19
S-
1
8
G
R
A
T
E
E
L
E
V
.
=
2
4
.
0
5
'
15
"
I
N
V
.
O
U
T
=
2
0
.
3
0
'
S-
1
7
G
R
A
T
E
E
L
E
V
.
=
2
4
.
0
5
'
15
"
I
N
V
.
I
N
=
2
0
.
1
6
'
15
"
I
N
V
.
O
U
T
=
1
9
.
5
0
'
S-
1
6
G
R
A
T
E
E
L
E
V
.
=
2
0
.
4
0
'
15
"
I
N
V
.
I
N
=
1
7
.
0
1
'
24
"
I
N
V
.
O
U
T
=
1
6
.
4
0
'
S-
1
5
M
A
N
H
O
L
E
C
O
V
E
R
E
L
E
V
.
=
2
3
.
3
4
'
24
"
I
N
V
.
I
N
=
1
6
.
3
0
'
18
"
I
N
V
.
I
N
=
2
1
.
6
9
'
EX
2
4
"
I
N
V
.
O
U
T
=
1
5
.
3
5
'
S-
1
9
F
L
A
R
E
D
E
N
D
S
E
C
T
I
O
N
15
"
I
N
V
.
I
N
=
2
2
.
0
0
27.17 LF OF
15" RCP
@ 0.50%
31.14 LF OF
15" RCP
@ 8.00%
19.71 LF OF
24" RCP
@ 0.50%
EXISTING
GROUND
PROPOSED
GRADE
S-8 TO MH-1
10
20
30
10
20
30
0+00
23
.
1
6
23
.
1
6
23
.
0
0
23
.
0
0
0+50
23
.
0
0
23
.
0
0
23
.
0
0
23
.
0
0
1+00
23
.
0
0
23
.
0
0
23
.
0
0
23
.
0
0
1+50
23
.
0
0
23
.
0
0
22
.
7
7
22
.
7
7
2+00
23
.
3
2
23
.
3
2
23
.
9
8
23
.
9
8
2+50
S-
8
G
R
A
T
E
E
L
E
V
.
=
2
1
.
1
3
'
15
"
I
N
V
.
O
U
T
=
1
7
.
0
0
'
MH
-
1
A
D
J
U
S
T
E
D
M
A
N
H
O
L
E
E
L
E
V
.
=
2
3
.
6
4
'
24
"
I
N
V
.
I
N
=
1
5
.
8
4
'
72
"
I
N
V
.
O
U
T
=
1
2
.
2
2
'
231.70 LF OF 24" RCP @ 0.50%
EXISTING GROUND
PROPOSEDGRADE
C-11
STORM
DRAINAGE
PROFILES
(SHEET 2 OF 2)
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
S
T
O
R
M
P
R
O
F
I
L
E
S
.
D
W
G
8
/
8
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
50'
HORIZONTAL SCALE IN FEET
0' 25'100'
5'
VE
R
T
I
C
A
L
S
C
A
L
E
I
N
F
E
E
T
0'
10
'
C-12
PAVING NOTES
AND DETAILS
PAVING NOTES
1. THE CONTRACTOR IS REQUIRED TO SUBMIT A DETAILED PAVING PLAN REFLECTING PROPOSED LIFT
THICKNESS, TRANSVERSE JOINT LAYOUTS, AND LONGITUDINAL JOINT LAYOUTS, A MINIMUM OF 30 DAYSPRIOR TO PAVING. THE CONTRACTOR SHALL ATTEND A PRE-PAVING CONFERENCE CONDUCTED BY THEENGINEER PRIOR TO THE START OF PAVING OPERATIONS. THE PAVING FOREMAN SHALL BE PRESENTAT THE CONFERENCE. THE CONTRACTOR SHALL BE PREPARED TO DISCUSS HIS PROPOSED
LAYDOWN/PAVING PLAN
2. THE CONTRACTOR SHALL PAVE TO ELEVATIONS PROVIDED ON THE PAVING PLAN, SEE SHEET C-09 TO
ENSURE FULL COMPLIANCE.
3. TACK COAT SHALL BE APPLIED BETWEEN EACH LIFT OF NCDOT 9.5B, AS DESCRIBED IN NCDOT 605..
4. LONGITUDINAL JOINTS WHICH ARE IRREGULAR, DAMAGED, UNCOMPACTED, OR OTHERWISE DEFECTIVEOR WHICH HAVE BEEN EXPOSED FOR MORE THAN 4 HOURS, OR WHOSE SURFACE TEMPERATURE HASCOOLED TO LESS THAN 160° F SHALL BE CUT BACK NO MORE THAN 12 INCHES TO EXPOSE A CLEAN,
SOUND SURFACE FOR THE FULL DEPTH OF THE COURSE. THE LONGITUDINAL JOINT SHALL BE SAWCUT
IF ANY, ALL, OR SOME COMBINATION(S) OF THE ABOVE CONDITIONS ARE PRESENT. ALL CONTACT
SURFACES SHALL BE CLEANED AND DRY PRIOR AND GIVEN A TACK COAT OF BITUMINOUS MATERIAL
PRIOR TO PLACING ANY FRESH MIXTURE AGAINST THE JOINT. THE COST OF THIS WORK AND TACK COAT
SHALL BE CONSIDERED INCIDENTAL TO THE COST OF THE BITUMINOUS COURSE.
5. 25' PAVERS WILL NOT BE ALLOWED. A JOINT WILL BE CONSIDERED "COLD" IF MORE THAN THIRTYMINUTES ELAPSE BETWEEN PAVING. TRANSVERSE JOINT SHALL BE MINIMIZED BY THE CONTRACTOR.
6. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING VERTICAL AND HORIZONTAL CONTROL FOR THE
PROJECT.
7. THE CONTRACTOR SHALL FIELD VERIFY TIE-IN LOCATIONS PRIOR TO PAVING OPERATIONS.
8. CONTRACTOR SHALL ENSURE POSITIVE DRAINAGE SO THAT RUNOFF WILL DRAIN BY OVERLAND SHEET
FLOW ACROSS NEW PAVEMENT AREAS TO NEW OR EXISTING DRAINAGE INLETS. EXISTING GRADES AND
DRAINAGE PATTERNS SHALL BE MAINTAINED AFTER CONSTRUCTION UNLESS OTHERWISE SHOWN ONPLANS.
9. CONNECTIONS TO EXISTING PAVEMENT SHALL BE MADE BY SAW CUTTING A NEAT VERTICAL LINE TOMATCH EXISTING PAVEMENT ELEVATIONS. EDGE SHALL BE TACKED PRIOR TO PAVING.
J.C.W.
J.C.W.
PROPOSED ASPHALT
PAVEMENTEXISTING PAVEMENT
PROPOSED ASPHALT
PROPOSED TACK
COAT ON FACE OF
SAW CUT (TYP.)
EXISTING CRUSHEDAGGREGATE BASECOURSE
EXISTING SUBBASE
/SUBGRADE
12"MIN.
PAVEMENT TIE-IN DETAIL
NOT TO SCALE
NEAT SAW CUT EXISTING PAVEMENTWITH VERTICAL FACE (TYP.)
PROPOSED NCDOT
520 AGGREGATE
BASE COURSE
PROPOSED SUBBASE /SUBGRADE
SEE NOTE 1
ACCESS ROAD PAVEMENT SECTION
NOT TO SCALE
6" NCDOT 520AGGREGATEBASE COURSE
COMPACTEDSUBGRADE
3" NCDOT 9.5B ASPHALT
SURFACE COURSE
(PLACED IN TWO LIFTS)
PARKING LOT PAVEMENT SECTION
NOT TO SCALE
6" NCDOT 520
AGGREGATE
BASE COURSE
EXISTING
SUBGRADE
NCDOT 600 PRIME COAT 3" NCDOT 9.5B ASPHALT
SURFACE COURSE
(PLACED IN TWO LIFTS)
NCDOT 605 TACK COAT
NCDOT 600 PRIME COAT
NCDOT 605 TACK COAT
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
P
A
V
E
M
E
N
T
D
E
T
A
I
L
S
.
D
W
G
4
/
2
7
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
5' S
I
D
E
W
A
L
K
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
TIE INTO EDGE
OF ROAD
TIE INTO EDGE
OF ROAD
INSTALL 2'-6"
CURB (TYP)
INSTALL 2'-6"CURB (TYP)
INSTALL 2'-6"
CURB (TYP)
INSTALL 2'-6"
CURB (TYP)
INSTALL 2'-6"
CURB (TYP)
INSTALL 6" CURB(TYP)
INSTALL 6" CURB --»
INSTALL 6" CURB «--
INSTALL 6" CURBAROUND ISLANDS (TYP)
INSTALL TYPE A
CURB RAMP
INSTALL TYPE A
CURB RAMP
INSTALL TYPE A
CURB RAMP
INSTALL TYPE 1
CURB RAMP
INSTALL TYPE 1
CURB RAMP
INSTALL TYPE ACURB RAMP
INSTALL TYPE A
CURB RAMP
INSTALL TYPE A
CURB RAMP
EDGE OF PAVEMENT
EDGE OF PAVEMENT
26.59
26.32
24.40
24.39
24.27
24.30
24.34
24.72
24.32
24.73
25.25
25.18
25.08
25.00
25.00
24.7524.4724.4724.3924.39
24.52
24.47
24.46
24.39
24.26
26.8026.39
26.54
26.09
26.48
26.1925.83
26.20
25.9425.56
25.91
25.6625.30
25.62
25.3725.03
25.34
25.0824.77
25.05
24.8024.50
24.84 24.6524.6424.26
24.49
24.2424.48
24.7224.30
26.77
28.77
24.71
24.83
24.97
25.10
25.26
25.37
25.50
25.63
25.77
25.96
26.04
26.17
26.30
26.43
26.55
26.75
26.83
26.96
27.10
27.23
27.38
27.48
27.61
27.73
27.90
27.98
28.10
28.23
28.36
28.48
28.60
28.73
24.55
24.76
24.95
25.09
25.22
25.35
25.49
25.62
25.75
25.88
26.02
26.15
26.28
26.42
26.55
26.68
26.82
26.95
27.08
27.21
27.35
27.48
27.61
27.72
27.85
27.98
28.10
28.23
28.35
28.47
28.60
28.72
28.84
24.83
25.00
25.20
25.34
25.47
25.60
25.74
25.87
26.00
26.13
26.27
26.40
26.55
26.67
26.80
26.93
27.07
27.20
27.33
27.46
27.60
27.73
27.84
27.98
28.10
28.23
28.35
28.48
28.60
28.72
28.84
28.97
29.09
25.11
25.29
25.45
25.59
25.72
25.85
25.99
26.12
26.25
26.39
26.52
27.15
26.80
26.92
27.05
27.18
27.32
27.45
27.59
27.71
27.85
27.98
28.72
28.36
28.47
28.61
28.72
28.85
28.98
29.09
29.21
25.39
25.57
25.70
25.83
25.97
26.10
26.24
26.37
26.50
26.64
26.76
26.80
26.94
27.16
27.30
27.43
27.57
27.70
27.83
27.96
28.09
28.22
28.24
28.37
28.60
28.73
28.85
28.98
29.09
29.22
29.34
25.67
25.82
25.95
26.08
26.22
26.35
26.49
26.62
26.75
26.89
27.02
26.90
26.99
27.40
27.55
27.68
27.82
27.95
28.08
28.21
28.35
28.48
28.27
28.47
28.85
28.98
29.10
29.23
29.35
29.47
25.91
26.03
26.16
26.30
26.43
26.56
26.70
26.83
26.97
27.10
27.24
27.02
27.03
27.52
27.77
27.90
28.04
28.17
28.30
28.43
28.57
28.70
28.31
28.58
29.07
29.20
29.32
29.44
29.56
25.63
25.78
25.92
26.09
26.22
26.35
26.53
26.66
26.81
26.94
27.08
26.98
27.07
27.48
27.62
27.75
27.89
28.02
28.15
28.28
28.42
28.54
28.34
28.53
28.90
29.00
29.09
29.19
29.30
25.36
25.53
25.67
25.87
26.01
26.17
26.35
26.48
26.64
26.78
26.93
26.97
27.12
27.34
27.47
27.60
27.74
27.87
28.00
28.13
28.27
28.38
28.38
28.52
28.73
28.80
28.86
29.44
25.09
25.28
25.66
26.00
26.48
26.78
27.07
27.19
27.59
27.85
28.12
28.23
28.57
28.68
24.82
25.03
25.22
25.45
25.60
25.82
26.00
26.15
26.32
26.46
26.63
26.77
26.92
27.04
27.17
27.30
27.44
27.57
27.70
27.83
27.97
28.09
28.17
28.31
28.41
28.48
28.59
24.33
28.25
24.62
24.84
25.06
25.29
25.51
25.70
25.86
26.03
26.19
26.36
26.49
26.63
26.76
26.89
27.03
27.16
27.29
27.42
27.56
27.69
27.81
27.91
28.02
28.12
28.29
28.83 29.17 29.56
29.69 29.60
29.41
29.78
28.97
24.55
24.79
25.01
25.23
25.43
25.65
25.83
26.00
26.16
26.31
26.48
26.62
26.76
26.89
27.02
27.15
27.29
27.42
27.55
27.68
27.82
27.93
28.04
28.15
28.25
28.36
25.17
24.47
24.69
29.04 28.94 29.05 29.30
29.81 29.68 29.51
29.63
29.02
28.09
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 5025 100
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
P
A
V
I
N
G
P
L
A
N
.
D
W
G
8
/
3
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-13
PAVING PLAN
NOTES
1. SEE SHEET C-12 FOR PAVEMENT NOTES AND
DETAILS.
2. SEE SHEET C-19 FOR GATE ENTRANCE, EXITAND BOLLARD DETAILS.
3. SEE SHEET C-14 FOR CURB RAMP DETAILS.
LEGEND
PROPOSED ASPHALT PAVEMENT
PROPOSED ASPHALT SIDEWALK
C-14
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
P
A
R
K
I
N
G
L
O
T
&
S
I
D
E
W
A
L
K
D
E
T
A
I
L
S
.
D
W
G
6
/
1
3
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
SIDEWALK AND
ISLAND DETAILS
2"
TYPICAL 2" THICK ASPHALT SIDEWALK SECTION
NOT TO SCALE
PROPOSED 2" THICKASPHALT NCDOT 610SIDEWALK
4" NCDOT 520 CRUSHED
AGGREGATE BASE COURSE
3" ASPHALT
PAVEMENT
PARKING LOT ISLAND DETAIL
NOT TO SCALE
LANDSCAPE ISLAND
6" CURB
6" NCDOT 520 AGGREGATE
BASE COURSE
6"2" R.
6", TYP.
3" ASPHALT
PAVEMENT
TYPE D CONCRETE CURB DETAIL
NOT TO SCALE
GRASS BUFFER
6" CURB
6" NCDOT 520 AGGREGATE
BASE COURSE
6"2" R.
6", TYP.
12" MIN. COMPACTED
SUBGRADE
1/8" R.
1/8" R.
3" ASPHALTPAVEMENT
2' 6" CURB & GUTTER DETAIL
NOT TO SCALE
6" NCDOT 520 AGGREGATE
BASE COURSE12" MIN. COMPACTED
SUBGRADE
6"1/8" R.2" R.
6", TYP.
GRASS BUFFER
2'
2'-6" CURB AND GUTTER
TYPE 1 CURB RAMP DETAIL
NOT TO SCALE
TYPE A CURB RAMP DETAIL
NOT TO SCALE
7", TYP.
1' 1", TYP.
C-15
MARKING NOTES
AND DETAILS
J.C.W.
J.C.W.
PARKING LOT TYPICAL PARKING SPACE
MARKING STOP DETAIL
NOT TO SCALE
9.0'
U.N.O.
MARKING 4"
WHITE, TYP.
18' TYP
MUTCD
R7-8
12"x18"
HANDICAP PARKING SIGN NOTES
1. ALL 12"x18" ACCESSIBLE SIGNS (R7-8 & R7-1) SHALL BEMOUNTED AT 7 FEET FROM GRADE TO BOTTOM EDGE OF SIGNFACE (MUTCD). MOUNTING HEIGHT CAN BE REDUCED TO 5
FEET IF PLACED IN AN AREA BETWEEN SIDEWALK AND
BUILDING FACE IN WHICH PEDESTRIANS ARE NOT EXPECTED
TO USE.
2. REFER TO MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES,
(MUTCD) U.S. DEPARTMENT OF TRANSPORTATION AND NORTHCAROLINA DEPARTMENT OF TRANSPORTATION SUPPLEMENT.
3. IF ACCESSIBLE ROUTE IS A RAISED SIDEWALK AREA, THENRAMPS ARE REQUIRED AT LOADING ZONE AREA.
4. SIGN: R7-8 (WITH ARROW) METAL LEGEND/BORDER-GREEN;
WHITE SYMBOL ON BLUE BACKGROUND; BACKGROUND-WHITE.
SIGN TO MEET CITY STANDARDS.
5. PENALTY SIGN BELOW (METAL) 3/8" WHITE BORDER;
BACKGROUND-BLUE; LEGEND IN WHITE. SIGN TO MEET LOCALSTANDARDS.
6. PLACE SIGN ON POST WITH 7' MIN. CLEARANCE FROM BOTTOMOF SIGN TO FINISHED GRADE. POST MUST BE SET IN
CONCRETE DIRECTLY BEHIND BACK OF CURB.
7. USE A U-TYPE FLANGED STEEL SECTION FOR SIGN POST
PAINTED WHITE AND ATTACHED WITH RUSTPROOF HARDWARE.
R7-8D
12"x9"9"
18"
12"
HANDICAP PARKING SIGNS
NOT TO SCALE
18'
3'-5"
5'
9'9'
18'
45°'
2'(TYP)
INSTALL
HANDICAP
PARKING
SIGN
4" WHITEPAINT STRIPE
HANDICAPPED
MARKER WHITE
PAINT (TYP)
C/L SPACE
HANDICAPPED SPACE MARKING
NOT TO SCALE
HANDICAP MARKING DETAIL
NOT TO SCALE
20.5"
20.5"
7" DIAMETER CIRCLE
3"
18"18"
WHITE PAINT3"
1.75"
24.75"
OUTSIDE
DIAMETER
MARKING NOTES
1. SEE SHEET #### FOR ####################### AND C-16 FOR MARKING PLAN - PARKING LOT.
2. CONTRACTOR SHALL CLEAN ANY DEBRIS AND SOIL FROM PAVEMENTS TO BE MARKED
IMMEDIATELY PRIOR TO MARKING LAYOUT AND MARKING. IF WATER IS TO BE USED TO CLEAN THE
PAVEMENT, THE PAVEMENT MUST BE DRY PRIOR TO MARKING LAYOUT AND MARKING.
3. THE PROPOSED MARKINGS, TEMPORARY AND PERMANENT, SHALL BE LAID OUT IN ADVANCE OFTHE MARKING APPLICATION. THE MARKING LAYOUT SHALL BE APPROVED BY THE AIRPORT ANDENGINEER PRIOR TO MARKING. ANY DEVIATIONS IN THE MARKING LAYOUT SHALL BE RESOLVED
PRIOR TO MARKING. A REGISTERED SURVEYOR SHALL LAYOUT ALL PAVEMENT MARKINGS. COST
FOR LAYOUT SHALL BE INCIDENTAL TO CONTRACT ITEM S-104 "PROJECT SURVEY AND STAKEOUT".
4. ALL MARKING EQUIPMENT SHALL BE CALIBRATED IN THE PRESENCE OF THE AIRPORT AND
ENGINEER PRIOR TO MARKING EACH DAY. THE CALIBRATION SHALL ENSURE CONSISTENCY IN THE
MARKING AND BEAD RATE APPLICATIONS. ANY MARKING EQUIPMENT USED FOR THE PROJECT
SHALL BE ADEQUATE TO COMPLETE THE WORK PER THE CONTRACT DOCUMENTS. AT ANY TIME,THE AIRPORT AND ENGINEER MAY DIRECT THE CONTRACTOR TO SUPPLY ADDITIONAL ORSUPPLEMENTAL EQUIPMENT TO COMPLETE THE WORK IF IT IS SHOWN THE EQUIPMENT BEING
USED IS NOT ADEQUATE TO COMPLETE THE WORK PER THE CONTRACT DOCUMENTS. ANY
ADDITIONAL OR SUPPLEMENTAL EQUIPMENT REQUIRED WILL BE SUPPLIED AT NO ADDITIONAL
COST TO THE AIRPORT.
5. ANY DEVIATIONS IN THE MARKING FROM THE APPROVED MARKING PLAN SHALL BE REPAIRED AT NO
COST TO THE AIRPORT. THE CONTRACTOR SHALL FOLLOW THE REPAIR METHOD DIRECTED BY THE
AIRPORT AND ENGINEER.
6. CONTRACTOR SHALL PROTECT ALL MARKINGS PLACED UNTIL THE PAVEMENT HAS BEEN TURNEDOVER TO THE AIRPORT. ANY DAMAGE TO PAVEMENT MARKINGS PRIOR TO TURN OVER TO THE
AIRPORT SHALL BE REPAIRED AND REMARKED AT NO COST TO THE AIRPORT.
7. MARKING AND MARKING REMOVAL SHALL BE COMPLETED PER ALL APPLICABLE MARKING PLANS.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
M
A
R
K
I
N
G
N
O
T
E
S
&
D
E
T
A
I
L
S
.
D
W
G
4
/
1
9
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
PEDESTRIAN CROSSWALK DETAIL
NOT TO SCALE
9.0'
1.0'
2.0', TYP.
2.0', TYP.
24" WHITE, TYP.
NOTE: SEE SHEETS C-14 AND #### FOR
LOCATIONS.
5' S
I
D
E
W
A
L
K
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
INSTALL CROSSWALK.
SEE DETAIL ON SHEET
C-15.
INSTALL DIRECTIONALARROWS. SEE DETAILON SHEET C-15
INSTALL DIRECTIONALARROWS. SEE DETAILON SHEET C-15
INSTALL DIRECTIONALARROWS. SEE DETAIL
ON SHEET C-15
INSTALL HANDICAPPARKING. SEE DETAIL ON
SHEET C-15.
INSTALL CROSSWALK.SEE DETAIL ON SHEETC-15.
INSTALL PAVEMENT
MARKING FOR PARKING
STALLS (TYP).
SEE DETAIL ON SHEET C-15.
4
S
P
A
C
E
S
@
9
'
14
S
P
A
C
E
S
@
9
'
5
S
P
A
C
E
S
@
9
'
14
S
P
A
C
E
S
@
9
'
14
S
P
A
C
E
S
@
9
'
10
S
P
A
C
E
S
@
9
'
8
S
P
A
C
E
S
@
9
'
12 S
P
A
C
E
S
@ 9'
10 S
P
A
C
E
S
@ 9'
9 SP
A
C
E
S
@ 9'
9 SP
A
C
E
S
@ 9'
10 S
P
A
C
E
S
@ 9'
13 S
P
A
C
E
S
@ 9'
11 S
P
A
C
E
S
@ 9'
3
S
P
A
C
E
S
@
9
'
24
S
P
A
C
E
S
@
9
'
14
S
P
A
C
E
S
@
9
'
14
S
P
A
C
E
S
@
9
'
14
S
P
A
C
E
S
@
9
'
14
S
P
A
C
E
S
@
9
'
14
S
P
A
C
E
S
@
9
'
14
S
P
A
C
E
S
@
9
'
14
S
P
A
C
E
S
@
9
'
5
S
P
A
C
E
S
@
9
'
4
S
P
A
C
E
S
@
9
'
4
S
P
A
C
E
S
@
9
'
4
S
P
A
C
E
S
@
9
'
4
S
P
A
C
E
S
@
9
'
4
S
P
A
C
E
S
@
9
'
4
S
P
A
C
E
S
@
9
'
36'
9'
18'
3
S
P
A
C
E
S
@
9
'
3
S
P
A
C
E
S
@
9
'
3
S
P
A
C
E
S
@
9
'
3
S
P
A
C
E
S
@
9
'
3
S
P
A
C
E
S
@
9
'
3
S
P
A
C
E
S
@
9
'
3
S
P
A
C
E
S
@
9
'
3
S
P
A
C
E
S
@
9
'
3
S
P
A
C
E
S
@
9
'
3
S
P
A
C
E
S
@
9
'
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 5025 100
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARY
INFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
M
A
R
K
I
N
G
P
L
A
N
.
D
W
G
8
/
1
4
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-16
MARKING PLAN -
PARKING LOT
NOTES
1. SEE SHEET C-15 FOR MARKING NOTESAND DETAILS.
2. SEE SHEET C-20 FOR PARKING LOT SIGNPLAN.
3. ALL PARKING STALLS SHALL BE A MINIMUMOF 18' IN LENGTH.
LEGEND
PROPOSED ASPHALT PAVEMENT
PROPOSED CONCRETE SIDEWALK
NOT TO SCALE
TYPICAL 3' HIGH WOOD POST FENCE WITH STEEL CABLE
8'-0" MAX. SPACING
POSTS SHALL BE EQUALLY SPACED
8'-0" MAX. SPACING
POSTS SHALL BE EQUALLY SPACED
6" DIA AMERICAN TIMBERAND STEEL WOODEN FENCEPOST OR APPROVED EQUAL
6" STAINLESSSTEEL EYE
3'
3'
3" SAG (MAX)
3/16" STAINLESS STEELCABLE (GRADE 316L) 1X19OR APPROVED EQUAL
NOT TO SCALE
TYPICAL 3' PEDESTRIAN ACCESS
6" DIA AMERICAN TIMBERAND STEEL WOODEN FENCEPOST OR APPROVED EQUAL
6" DIA AMERICAN TIMBER
AND STEEL WOODEN FENCE
POST OR APPROVED EQUAL
3'-0" MAX. SPACING PEDESTRIAN ACCESS
3/16" STAINLESS STEEL
CABLE (GRADE 316L) 1X19
OR APPROVED EQUAL
FINAL GRADE
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
F
E
N
C
I
N
G
P
L
A
N
.
D
W
G
8
/
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-17
FENCING NOTES
AND DETAILS
FENCE NOTES
1. ALL CONSTRUCTION METHODS AND EQUIPMENT EMPLOYED IN THE FENCE WORK SHALL BE IN ACCORDANCE WITH THEREQUIREMENTS OF THE SPECIFICATIONS OF THE MANUFACTURER OF THE FENCE MATERIALS BEING USED, AND SUCH THATTHE RESULTING STRUCTURE WILL PROVIDE THE EXPECTED SERVICE AND BE DURABLE AND COMPLETE IN EVERY DETAIL.
THE INTENT OF THE CONTRACT IS TO PROVIDE FOR THE CONSTRUCTION AND COMPLETION OF EVERY DETAIL OF THE
WORK DESCRIBED. DETAILS SHOWN IN THESE DRAWINGS INDICATE GENERAL INTENT, SPECIFIC MANUFACTURER DETAILS
MAY VARY AND ARE SUBJECT TO ENGINEER'S APPROVAL.
2. NEW FENCE LOCATIONS MAY VARY DUE TO SITE CONDITIONS AND CONSTRAINTS IN ORDER TO AVOID CONFLICT WITH
EXISTING UTILITIES, UNDESIRABLE TERRAIN AND STRUCTURES. CONTRACTOR SHALL FLAG NEW FENCE ALIGNMENTLOCATIONS AND OBTAIN APPROVAL FROM ENGINEER PRIOR TO CONSTRUCTION.
3. ALL MATERIALS USED FOR PERMANENT CONSTRUCTION SHALL BE NEW. USED MATERIALS ARE STRICTLY PROHIBITEDUNLESS APPROVED BY THE ENGINEER PRIOR TO USE.
4. ALL INSTALLED FENCE POST SHALL BE 6" DIA ROUND DOOMED WOODEN POST OR APPROVED EQUAL. ALL POSTS SHALL BE
INSTALLED 3' IN DEPTH BELOW FINAL GRADE. WOODEN POST SHALL HAVE A HEIGHT OF 3' ABOVE FINAL GRADE.
5' S
I
D
E
W
A
L
K
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
N: 191,050.81
E: 2,328,765.85
N: 190,991.06
E: 2,328,699.89
N: 190,987.70
E: 2,328,696.18
N: 190,927.95
E: 2,328,630.22
N: 190,924.59E: 2,328,626.52N: 190,858.80
E: 2,328,553.89
N: 190,855.44
E: 2,328,550.18
N: 190,773.09
E: 2,328,459.27
N: 190,778.15
E: 2,328,473.80
N: 190,746.28
E: 2,328,502.66
N: 190,605.05E: 2,328,361.65
N: 190,607.64E: 2,328,038.31
N: 190,745.11
E: 2,328,439.55
N: 190,516.89E: 2,328,187.61
INSTALL
APPROXIMATELY 89 LF
OF PROPOSED FENCE.
INSTALL
APPROXIMATELY 98 LF
OF PROPOSED FENCE.
INSTALLAPPROXIMATELY 123 LF
OF PROPOSED FENCE.
INSTALLAPPROXIMATELY 244 LF
OF PROPOSED FENCE.
N: 190,711.08
E: 2,327,944.71
N: 191,077.96E: 2,328,741.26
INSTALL
APPROXIMATELY 159 LF
OF PROPOSED FENCE.
INSTALL
APPROXIMATELY 362 LFOF PROPOSED FENCE.
N: 190,533.19
E: 2,328,172.84
N: 190,533.40E: 2,328,168.61
INSTALL
APPROXIMATELY 294 LF
OF PROPOSED FENCE.
3' PEDESTRIAN ACCESS
N: 190,714.27E: 2,327,946.00
N: 190,811.09E: 2,328,052.89
N: 190,813.10E: 2,328,055.11
3' PEDESTRIAN ACCESS
N: 190,892.32E: 2,328,142.56
3' PEDESTRIAN ACCESS
N: 190,894.34E: 2,328,144.79
N: 190,605.42E: 2,328,040.32
3' PEDESTRIAN ACCESS
N: 190,973.56
E: 2,328,232.24
3' PEDESTRIAN ACCESS
N: 190,975.57
E: 2,328,234.46
N: 191,060.83
E: 2,328,328.59
3' PEDESTRIAN ACCESS
N: 191,062.85
E: 2,328,330.81
N: 191,138.53
E: 2,328,414.36
3' PEDESTRIAN ACCESS
N: 191,139.45E: 2,328,416.97
N: 191,112.44E: 2,328,576.60
N: 191,113.02E: 2,328,573.65
3' PEDESTRIAN ACCESS
INSTALL
APPROXIMATELY 113 LF
OF PROPOSED FENCE.
INSTALL
APPROXIMATELY 127 LFOF PROPOSED FENCE.
INSTALLAPPROXIMATELY 118 LFOF PROPOSED FENCE.
INSTALLAPPROXIMATELY 118 LFOF PROPOSED FENCE.
INSTALL
APPROXIMATELY 145 LF
OF PROPOSED FENCE.
INSTALL
APPROXIMATELY 140 LFOF PROPOSED FENCE.
INSTALL
APPROXIMATELY 187 LF
OF PROPOSED FENCE.
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 5025 100
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
F
E
N
C
I
N
G
P
L
A
N
.
D
W
G
8
/
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-18
FENCING PLAN
NOTES
1. ALL FENCE POSTS SHALL BE 6' LONG
WOODEN POSTS WITH A MINIMUM 6"
DIAMETER. FENCE POST SHALL HAVE
EITHER A FLAT OR ROUNDED TOP.
2. FENCE POST SHALL BE INSTALLED NO
GREATER THAN 8 FT APART AND EQUALLY
SPACED.
3. FENCE POST SHALL BE INSTALLED 3'
ABOVE FINAL GRADE.
4. WIRE CABLE SHALL BE 3/16" STAINLESS
STEEL CABLE (GRADE 316L) 1 X 19 OR
APPROVED EQUAL.
5. WIRE CABLE SHALL HAVE A MAXIMUM OF
3" SAG FROM STAINLESS STEEL EYE
CONNECTORS.
LEGEND
PROPOSED FENCE
INSTALL BARRIER GATE
INSTALL BARRIER GATE
INSTALL
BARRIER
GATE
INSTALL
BARRIER
GATE
INSTALL GATED
LICENSE PLATERECOGNITION
INSTALL GATED
LICENSE PLATE
RECOGNITION
INSTALL EXPRESS
TERMINAL FOR
ENTRANCE
INSTALL EXPRESS
TERMINAL FOR
ENTRANCE
INSTALL EXPRESS
TERMINAL FOR EXIT
INSTALL EXPRESS
TERMINAL FOR EXIT
INSTALLBOLLARDS (TYP)
INSTALL
BOLLARDS (TYP)
C-19
GATE ENTRANCE,
EXIT AND
BOLLARD DETAILS
(SHEET 1 OF 4)
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
G
A
T
E
D
E
T
A
I
L
S
.
D
W
G
8
/
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
NOTES
1. ACCESS PADS SHALL BE INSTALLED PER DETAIL.
2. MEANS AND METHODS FOR INSTALLING BOLLARDS SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR.
GRAPHIC SCALE IN FEET
0 52.5 10
North
4'
18"12"
3'
SMOOTH
CONCRETE DOME 6" SCHEDULE 40 STEEL PIPE, PRIMEAND PAINT TEAL. .
EXISTING GROUND
CONCRETE FOUNDATION
BOLLARD DETAIL
NOT TO SCALE
NOTES
1. THE CONCRETE BASE OF THE BOLLARD SHALL BE INSTALLEDFLUSH WITH THE EXISTING PAVEMENT WITH NO ADDITIONALPAVEMENT INSTALLED OVER IT.
2. BOLLARDS SHALL BE INSTALLED AROUND GATES, LPRS AND
TERMINALS.
C-19A
GATE ENTRANCE, EXIT
AND BOLLARDS
DETAILS (SHEET 2 OF 4)
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
G
A
T
E
D
E
T
A
I
L
S
.
D
W
G
8
/
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-19B
GATE ENTRANCE, EXIT
AND BOLLARDS
DETAILS (SHEET 3 OF 4)
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
G
A
T
E
D
E
T
A
I
L
S
.
D
W
G
8
/
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-19C
GATE ENTRANCE, EXIT
AND BOLLARDS DETAILS
(SHEET 4 OF 4)
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
G
A
T
E
D
E
T
A
I
L
S
.
D
W
G
8
/
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
5' S
I
D
E
W
A
L
K
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
INSTALL HANDICAP
PARKING SIGN. SEE
DETAIL ON SHEET C-15.
PROPOSED "NOPARKING" SIGN
PROPOSED "NO LEFTTURN" SIGN
RE-LOCATION
FOR EXISTING
"ONE WAY" SIGN
RE-LOCATIONFOR EXISTING ILM "EXIT" SIGN
PROPOSED "STOP" SIGN
RE-LOCATION OF
"CREDIT CARD PARKING& DELIVERIES" SIGN
STOP
RE-LOCATION
OF EXISTING
"DO NOT ENTER" SIGN
PROPOSED
DIRECTIONAL
"ECONOMY LOT"
SIGN
PROPOSED FLASHING
PEDESTRIAN
CROSSWALK SIGN
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 5025 100
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
P
A
R
K
I
N
G
L
O
T
S
I
G
N
P
L
A
N
.
D
W
G
8
/
8
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-20
PARKING LOT
SIGN PLAN
NOTE
1. SEE SHEET C-15 FOR HANDICAP PARKINGSIGN DETAILS
LEGEND
PROPOSED SIGN
5' S
I
D
E
W
A
L
K
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
PROPOSED 28' TYPE A
LIGHT FIXTURE
EXISTING LIGHT POLE TO BE
REMOVED AND DELIVERED TO ILM
FACILITIES UNLESS DIRECTED
OTHERWISE BY THE AIRPORT.
PROPOSED 2"
SCHEDULE 40
PVC CONDUIT
PROPOSED 200 AMP MDP
PANEL/METER.
A
A
A
A
A
A
A
A
A
A
A
A
A
DUKE POWERTRANSFORMER
PROPOSED 28' TYPE A
LIGHT FIXTURE
2" CONDUIT TO BE STUB UPAND CAP OFF FOR FUTUREEXTENSION OF THECIRCUIT
PROPOSED 28' TYPE ALIGHT FIXTURE
30
24
21
26
26
27
27 28
29
26
27
23
24
23
24
25
23
2
5
26
27
28
22 23 24 25
2021
23
2
4
2
5
2
7
28
29
26
27
18
19
20
21
22
23
24
A
PROPOSED 100 AMP
PANEL PG
COMMUNICATIONS PANEL
HANDHOLE FOR FUTURE
CONNECTIONS
EXIT GATE 1
PANEL PG
CIRCUIT 1
EXIT GATE 2
PANEL PGCIRCUIT 2
ENTRANCE GATE 1PANEL PG
CIRCUIT 3
ENTRANCE GATE 2
PANEL PG
CIRCUIT 4
PROPOSED 200 AMP MDP
UNDERGROUND
PERMANENT SERVICE. SEE
SHEET C-22 FOR DETAIL.
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 5025 100
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
E
L
E
C
T
R
I
C
A
L
P
L
A
N
.
D
W
G
8
/
1
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-21
ELECTRICAL AND
LIGHTING PLAN
LEGEND
TYPE A - 28' DOUBLE LIGHT FIXTURE
PROPOSED CONDUIT AND CABLE
A
MDP PANEL:
CIRCUIT 1 RED (1,3) PARKING LOT LIGHTS
CIRCUIT 2 GREEN (2,4) PARKING LOT LIGHTS
CIRCUIT 3 BLUE (5,7) PARKING LOT LIGHTS
CIRCUIT 4 BLACK (6,8) PANEL PG
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
E
L
E
C
T
R
I
C
A
L
P
L
A
N
.
D
W
G
8
/
1
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
C-22
ELECTRICAL AND
LIGHTING DETAILS
EC-01
EROSION AND
SEDIMENT
CONTROL NOTES
(SHEET 1 OF 3)
J.C.W.
J.C.W.
1. ALL EROSION AND SEDIMENT CONTROL MEASURES WILL BE CHECKED FOR STABILITY AND
OPERATION FOLLOWING EACH RAINFALL EVENT AND/OR NO LESS THAN ONCE EVERY WEEK.
2. ANY NEEDED REPAIRS SHALL BE MADE IMMEDIATELY TO ENSURE CONTINUED FUNCTION OF ALLPRACTICES AS DESIGNED.
3. ALL SEEDED AREAS SHALL BE RE-SEEDED, FERTILIZED, AND MULCHED AS NECESSARY TOESTABLISH SUITABLE GROUND COVER, ACCORDING TO THE SEEDING AND MULCHING
SPECIFICATIONS.
4. CONTRACTOR TO PERFORM ROUTINE REVIEW OF THE SILT FENCES TO ENSURE PROPER
FUNCTION. FENCES TO BE CLEANED ONCE SEDIMENT DEPTH REACHES 6".
5. ADDITIONAL MAINTENANCE, AS REQUIRED BY NCDEQ AND THE ENGINEER, SHALL BE
COMPLETED AS DIRECTED.
MAINTENANCE PLAN
1. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR HAVING VISITED THE SITE AND HAVINGFAMILIARIZED HIMSELF WITH THE EXISTING CONDITIONS PRIOR TO SUBMITTING HIS BID.
2. THE CONTRACTOR SHALL UTILIZE A NORTH CAROLINA LICENSED SURVEYOR FOR
CONSTRUCTION RELATED STAKE-OUT REQUIREMENTS.
3. THE CONTRACTOR SHALL MAINTAIN POSITIVE DRAINAGE IN ALL DISTURBED AREAS AND
DEWATER AS NECESSARY.
4. ALL DISTURBED AREAS, INCLUDING THE CONTRACTORS STAGING AREA, HAUL ROUTES,
GRADING LIMITS, ETC., SHALL BE RESTORED TO A SMOOTH LINE AND GRADE WITH POSITIVEDRAINAGE. THE CONTRACTOR SHALL SEED AND MULCH ALL DISTURBED AREAS. THERE WILLBE NO MEASUREMENT FOR PAYMENT OF SEEDING AND MULCHING REQUIRED FOR AREASOUTSIDE LIMITS OF DISTURBANCE DISTURBED BY THE CONTRACTOR.
5. THE CONTRACTOR WILL BE REQUIRED TO TRANSPORT AND STORE ALL EQUIPMENT AND
MATERIALS IN A MANNER WHICH WILL NOT DAMAGE ANY EXISTING PAVEMENT, BUILDINGS,
SIGNS, FACILITIES, ETC. ANY DAMAGE WILL BE REPAIRED BY THE CONTRACTOR AT NO COST TO
THE OWNER. THE CONTRACTOR SHALL KEEP ACCESS ROUTES CLEAN AND FREE OF LOOSE
DEBRIS FROM CONSTRUCTION MATERIALS. THE CONTRACTOR SHALL ALSO BE RESPONSIBLEFOR DAILY CLEARING ALL DEBRIS FROM PAVEMENTS TRAVERSED BY CONSTRUCTIONEQUIPMENT.
1. THE CONTRACTOR SHALL PROVIDE SILT FENCE AND/OR CONTROL DEVICES, AS MAY BE
REQUIRED, TO CONTROL SOIL EROSION DURING CONSTRUCTION. ALL DISTURBED AREAS SHALLBE CLEANED, GRADED AND STABILIZED WITH GRASSING IMMEDIATELY AFTER CONSTRUCTION.
2. EXCEPT AS PROVIDED BELOW, STABILIZATION MEASURES SHALL BE INITIATED AS SOON ASPRACTICABLE IN PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY
OR PERMANENTLY CEASED, BUT IN NO CASE MORE THAN 14 DAYS AFTER A CONSTRUCTION
ACTIVITY IN THAT PORTION OF THE SITE HAS TEMPORARILY OR PERMANENTLY CEASED.
3. CONTRACTOR'S TEMPORARY EROSION CONTROL - TEMPORARY DRAINS, SILT FENCING, AND
DRAINAGE DITCHES, ETC., NOT SHOWN ON THE PLANS, OR NOTED HEREIN, SHALL BE INSTALLEDBY THE CONTRACTOR TO INTERCEPT OR DIVERT SURFACE WATER RUNOFF WHICH MAY AFFECTTHE WORK. THESE DRAINS AND DITCHES SHALL BE MAINTAINED BY THE CONTRACTORTHROUGHOUT THE DURATION OF THE CONTRACT. UPON COMPLETION, THE CONTRACTOR SHALL
RESTORE THE SITE TO ITS ORIGINAL CONDITION.
4. SPECIFICATIONS ARE PROVIDED AS OUTLINE REQUIREMENTS FOR THE CONTRACTOR TO APPLY
WATER, CHEMICALS, VEGETATION OR OTHER MATERIALS TO PREVENT THE OCCURRENCE OF
DUST WHICH WILL BE OBJECTIONABLE TO THE OPERATIONS/USERS OF THE AIRPORT AS
OUTLINED IN THE PROJECT SPECIAL PROVISIONS, NO SEPARATE PAYMENT WILL BE MADE.CONTRACTOR SHALL ALSO BE OBLIGATED TO DISCONTINUE OPERATIONS WHICH VIOLATEEXISTING LAWS AND REGULATIONS.
5. CONTRACTOR SHALL LIMIT AREAS OF DISTURBANCE AS MUCH AS POSSIBLE DURING THE
COURSE OF THE PROJECT, AND STABILIZE AREAS AS WORK IS COMPLETED. NO SEPARATE
MEASUREMENT WILL BE MADE FOR PAYMENT FOR AREAS REQUIRING SEEDING AND MULCHING
OUTSIDE OF THE LIMITS OF CONSTRUCTION, THIS WORK SHALL BE PAID AT THE CONTRACTORS
EXPENSE.
6. ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSPECTED BY THE CONTRACTOR
EVERY SEVEN (7) DAYS OR AFTER EACH RAINFALL OCCURRENCE THAT EXCEEDS ONE-HALF (1/2)INCH. DAMAGED OR INEFFECTIVE DEVICES SHALL BE REPAIRED OR REPLACED AS NECESSARYBY THE CONTRACTOR, NO SEPARATE PAYMENT WILL BE MADE.
7. ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED DURING ALL PHASES OF
CONSTRUCTION UNTIL THE COMPLETION OF ALL CONSTRUCTION ACTIVITIES AND ALL DISTURBED
AREAS HAVE BEEN STABILIZED. ADDITIONAL CONTROL DEVICES MAY BE REQUIRED DURING
CONSTRUCTION IN ORDER TO CONTROL EROSION AND/OR OFFSITE SEDIMENTATION. ALL
TEMPORARY CONTROL DEVICES SHALL BE REMOVED ONCE CONSTRUCTION IS COMPLETE ANDTHE SITE IS STABILIZED UNLESS OTHERWISE ORDERED BY THE ENGINEER.
8. THE CONTRACTOR MUST TAKE NECESSARY ACTION TO MINIMIZE THE TRACKING OF MUD ONTOTHE PAVED ROADWAY CONSTRUCTION AREAS. THE CONTRACTOR SHALL DAILY REMOVE
MUD/SOIL FROM PAVEMENT, OR AS DIRECTED BY ENGINEER.
9. REMOVAL OF A SEDIMENT AND EROSION CONTROL MEASURE SHALL BE AS DIRECTED BY NCDEQ
AND THE ENGINEER. NO MEASURE SHALL BE REMOVED UNTIL DIRECTED TO THE CONTRACTOR IN
WRITING.
SEEDING MIXTURE SPECIES RATE (LB/ACRE)RYE (GRAIN) 120ANNUAL LESPEDEZA 50(KOBE IN PIEDMONT AND
COASTAL PLAIN, KOREAN IN MOUNTAINS)
OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYOND
JUNE.
SEEDING DATES:
COASTAL PLAIN: DEC 1 - APRIL 15
SOIL AMENDMENTSFOLLOW RECOMMENDATIONS OF SOIL TESTS, OR APPLY 2,000 LB/ACRE GROUNDAGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER.
MULCH
APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A
MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A
MULCH ANCHORING TOOL.
MAINTENANCERE-FERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RE-SEED, RE-FERTILIZE AND MULCHIMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE.
SEEDING MIXTURE SPECIES RATE (LB/ACRE)(GRAIN) 40
IN THE MOUNTAINS, A SMALL-STEMMED SUDANGRASS MAY BE SUBSTITUTED AT A RATE OF 50LBS/ACRE.
SEEDING DATES:
COASTAL PLAIN: APRIL 15 - AUG. 15
SOIL AMENDMENTS
FOLLOW RECOMMENDATIONS OF SOIL TESTS, OR APPLY 2,000 LB/ACRE GROUND
AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER.
MULCHAPPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR AMULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A
MULCH ANCHORING TOOL.
MAINTENANCE
RE-FERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RE-SEED, RE-FERTILIZE AND MULCH
IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE.
SEEDING MIXTURE SPECIES RATE (LB/ACRE)
RYE (GRAIN) 120
SEEDING DATES:
COASTAL PLAIN : AUG. 15 - DEC. 15
SOIL AMENDMENTSFOLLOW RECOMMENDATIONS OF SOIL TESTS, OR APPLY 2,000 LB/ACRE GROUNDAGRICULTURAL LIMESTONE AND 1,000 LB/ACRE 10-10-10 FERTILIZER.
MULCH
APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A
MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A
MULCH ANCHORING TOOL.
MAINTENANCEREPAIR AND RE-FERTILIZE DAMAGED AREAS IMMEDIATELY. TOPDRESS WITH 50 LBS/ACRE OFNITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15,OVERSEED WITH 50 LBS/ACRE KOBE LEPEDEZA IN LATE FEBRUARY OR EARLY MARCH.
SEEDING MIXTURE SPECIES RATE (LB/ACRE)TALL FESCUE 80
PENSACOLA BAHIAGRASS 50
SERICEA LESPEDEZA 30
KOBE LESPEDEZA 10
SEEDING NOTE:
1. FROM SEPT. 1-MAR. 1, USE UNSCARIFIED SEED FOR SERICEA LESPEDEZA.2. ON POORLY DRAINED SITES, OMIT SERICEA AND INCREASE KOBE TO 30 LB/ACRE.3. WHERE A NEAT APPEARANCE IS DESIRED, OMIT SERICEA AND INCREASE KOBE TO 40 LB/ACRE.
NURSE PLANTS
BETWEEN APRIL 15 AND AUG. 15, ADD 10 LB/ACRE GERMAN MILLET OR 15 LB/ACRE SUDANGRASS.
PRIOR TO MAY 1 OR AFTER AUG. 15, ADD 25 LB/ACRE RYE (GRAIN).
SEEDING DATES
BEST POSSIBLE
EARLY SPRING: FEB. 15-MAR. 20 FEB. 15-APR. 30
FALL SEPT. 1-SEPT. 30 SEPT. 1-OCT. 31
SOIL AMENDMENTSAPPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 3,000-5,000LBS/ACRE
GROUND AGRICULTURAL LIMESTONE (USE THE LOWER RATE ON SANDY SOILS) AND 1,000
LB/ACRE 10-10-10 FERTILIZER.
MULCH
APPLY 4,000LB/ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCH.
ANCHOR MULCH BY TACKING WITH ASPHALT, ROVING OR BY CRIMPING WITH A MULCH ANCORINGTOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL.
MAINTENANCEIF GROWTH IS LESS THAN FULLY ADEQUATE, RE-FERTILIZE IN THE SECOND YEAR, ACCORDING TO
SOIL TESTS OR TOPDRESS WITH 500 LB/ACRE 10-10-10 FERTILIZER. MOW AS NEEDED WHEN
SERICEA IS OMITTED FROM THE MIXTURE. RESEED, FERTILIZE AND MULCH DAMAGED AREAS
IMMEDIATELY.
TEMPORARY SEEDING SCHEDULE - SUMMER MIXTURE
TEMPORARY SEEDING SCHEDULE - FALL MIXTURE
PERMANENT SEEDING SCHEDULE - MIXTURE
EROSION AND SEDIMENT CONTROL NOTES
SITE WORK, GRADING, AND DRAINAGE NOTES
TEMPORARY SEEDING SCHEDULE LATE WINTER /
EARLY SPRING MIXTURE
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
E
S
C
N
O
T
E
S
.
D
W
G
7
/
2
4
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
NCG01 GROUND STABILIZATION AND MATERIALS HANDLING EFFECTIVE: 04/01/19
GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITHTHE NCG01 CONSTRUCTION GENERAL PERMIT
Implementing the details and specifications on this plan sheet will result in the constructionactivity being considered compliant with the Ground Stabilization and Materials Handling
sections of the NCG01 Construction General Permit (Sections E and F, respectively). Thepermittee shall comply with the Erosion and Sediment Control plan approved by thedelegated authority having jurisdiction. All details and specifications shown on this sheetmay not apply depending on site conditions and the delegated authority having jurisdiction.
GROUND STABILIZATION SPECIFICATION
STABILIZE THE GROUND SUFFICIENTLY SO THAT RAIN WILL NOT DISLODGE THE SOIL. USE ONE OF THETECHNIQUES IN THE TABLE BELOW:
POLYACRYLAMIDES (PAMS) AND FLOCCULANTS
1. SELECT FLOCCULANTS THAT ARE APPROPRIATE FOR THE SOILS BEING EXPOSED DURING
CONSTRUCTION, SELECTING FROM THE NC DWR LIST OF APPROVED PAMS/FLOCCULANTS.
2. APPLY FLOCCULANTS AT OR BEFORE THE INLETS TO EROSION AND SEDIMENT CONTROLMEASURES.
3. APPLY FLOCCULANTS AT THE CONCENTRATIONS SPECIFIED IN THE NC DWR LIST OF APPROVED
PAMS/FLOCCULANTS AND IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
4. PROVIDE PONDING AREA FOR CONTAINMENT OF TREATED STORMWATER BEFOREDISCHARGING OFFSITE.
5. STORE FLOCCULANTS IN LEAK-PROOF CONTAINERS THAT ARE KEPT UNDER STORM-RESISTANTCOVER OR SURROUNDED BY SECONDARY CONTAINMENT STRUCTURES.
HAZARDOUS AND TOXIC WASTE
1. CREATE DESIGNATED HAZARDOUS WASTE COLLECTION AREAS ON-SITE.
2. PLACE HAZARDOUS WASTE CONTAINERS UNDER COVER OR IN SECONDARY CONTAINMENT.
3. DO NOT STORE HAZARDOUS CHEMICALS, DRUMS OR BAGGED MATERIALS DIRECTLY ON THEGROUND.
EQUIPMENT AND VEHICLE MAINTENANCE
1. MAINTAIN VEHICLES AND EQUIPMENT TO PREVENT DISCHARGE OF FLUIDS.
2. PROVIDE DRIP PANS UNDER ANY STORED EQUIPMENT.
3. IDENTIFY LEAKS AND REPAIR AS SOON AS FEASIBLE, OR REMOVE LEAKING EQUIPMENT FROMTHE PROJECT.
4. COLLECT ALL SPENT FLUIDS, STORE IN SEPARATE CONTAINERS AND PROPERLY DISPOSE ASHAZARDOUS WASTE (RECYCLE WHEN POSSIBLE).
5. REMOVE LEAKING VEHICLES AND CONSTRUCTION EQUIPMENT FROM SERVICE UNTIL THEPROBLEM HAS BEEN CORRECTED.
6. BRING USED FUELS, LUBRICANTS, COOLANTS, HYDRAULIC FLUIDS AND OTHER PETROLEUMPRODUCTS TO A RECYCLING OR DISPOSAL CENTER THAT HANDLES THESE MATERIALS.
LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE
1. NEVER BURY OR BURN WASTE. PLACE LITTER AND DEBRIS IN APPROVED WASTE CONTAINERS.
2. PROVIDE A SUFFICIENT NUMBER AND SIZE OF WASTE CONTAINERS (E.G DUMPSTER, TRASH
RECEPTACLE) ON SITE TO CONTAIN CONSTRUCTION AND DOMESTIC WASTES.
3. LOCATE WASTE CONTAINERS AT LEAST 50 FEET AWAY FROM STORM DRAIN INLETS ANDSURFACE WATERS UNLESS NO OTHER ALTERNATIVES ARE REASONABLY AVAILABLE.
4. LOCATE WASTE CONTAINERS ON AREAS THAT DO NOT RECEIVE SUBSTANTIAL AMOUNTS OFRUNOFF FROM UPLAND AREAS AND DOES NOT DRAIN DIRECTLY TO A STORM DRAIN, STREAMOR WETLAND.
5. COVER WASTE CONTAINERS AT THE END OF EACH WORKDAY AND BEFORE STORM EVENTS ORPROVIDE SECONDARY CONTAINMENT. REPAIR OR REPLACE DAMAGED WASTE CONTAINERS.
6. ANCHOR ALL LIGHTWEIGHT ITEMS IN WASTE CONTAINERS DURING TIMES OF HIGH WINDS.
7. EMPTY WASTE CONTAINERS AS NEEDED TO PREVENT OVERFLOW. CLEAN UP IMMEDIATELY IFCONTAINERS OVERFLOW.
8. DISPOSE WASTE OFF-SITE AT AN APPROVED DISPOSAL FACILITY.
9. ON BUSINESS DAYS, CLEAN UP AND DISPOSE OF WASTE IN DESIGNATED WASTE CONTAINERS.
PAINT AND OTHER LIQUID WASTE
1. DO NOT DUMP PAINT AND OTHER LIQUID WASTE INTO STORM DRAINS, STREAMS ORWETLANDS.
2. LOCATE PAINT WASHOUTS AT LEAST 50 FEET AWAY FROM STORM DRAIN INLETS AND SURFACEWATERS UNLESS NO OTHER ALTERNATIVES ARE REASONABLY AVAILABLE.
3. CONTAIN LIQUID WASTES IN A CONTROLLED AREA.
4. CONTAINMENT MUST BE LABELED, SIZED AND PLACED APPROPRIATELY FOR THE NEEDS OF SITE.
5. PREVENT THE DISCHARGE OF SOAPS, SOLVENTS, DETERGENTS AND OTHER LIQUID WASTESFROM CONSTRUCTION SITES.
PORTABLE TOILETS
1. INSTALL PORTABLE TOILETS ON LEVEL GROUND, AT LEAST 50 FEET AWAY FROM STORM DRAINS,STREAMS OR WETLANDS UNLESS THERE IS NO ALTERNATIVE REASONABLY AVAILABLE. IF 50FOOT OFFSET IS NOT ATTAINABLE, PROVIDE RELOCATION OF PORTABLE TOILET BEHIND SILTFENCE OR PLACE ON A GRAVEL PAD AND SURROUND WITH SAND BAGS.
2. PROVIDE STAKING OR ANCHORING OF PORTABLE TOILETS DURING PERIODS OF HIGH WINDS ORIN HIGH FOOT TRAFFIC AREAS.
3. MONITOR PORTABLE TOILETS FOR LEAKING AND PROPERLY DISPOSE OF ANY LEAKED MATERIAL.UTILIZE A LICENSED SANITARY WASTE HAULER TO REMOVE LEAKING PORTABLE TOILETS ANDREPLACE WITH PROPERLY OPERATING UNIT.HERBICIDES, PESTICIDES AND RODENTICIDES
1. STORE AND APPLY HERBICIDES, PESTICIDES AND RODENTICIDES IN ACCORDANCE WITH LABELRESTRICTIONS.
2. STORE HERBICIDES, PESTICIDES AND RODENTICIDES IN THEIR ORIGINAL CONTAINERS WITHTHE LABEL, WHICH LISTS DIRECTIONS FOR USE, INGREDIENTS AND FIRST AID STEPS IN CASE OFACCIDENTAL POISONING.
3. DO NOT STORE HERBICIDES, PESTICIDES AND RODENTICIDES IN AREAS WHERE FLOODING ISPOSSIBLE OR WHERE THEY MAY SPILL OR LEAK INTO WELLS, STORMWATER DRAINS, GROUNDWATER OR SURFACE WATER. IF A SPILL OCCURS, CLEAN AREA IMMEDIATELY.
4. DO NOT STOCKPILE THESE MATERIALS ONSITE.
CONCRETE WASHOUTS
1. DO NOT DISCHARGE CONCRETE OR CEMENT SLURRY FROM THE SITE.
2. DISPOSE OF, OR RECYCLE SETTLED, HARDENED CONCRETE RESIDUE IN ACCORDANCE WITHLOCAL AND STATE SOLID WASTE REGULATIONS AND AT AN APPROVED FACILITY.
3. MANAGE WASHOUT FROM MORTAR MIXERS IN ACCORDANCE WITH THE ABOVE ITEM AND INADDITION PLACE THE MIXER AND ASSOCIATED MATERIALS ON IMPERVIOUS BARRIER ANDWITHIN LOT PERIMETER SILT FENCE.
4. INSTALL TEMPORARY CONCRETE WASHOUTS PER LOCAL REQUIREMENTS, WHERE APPLICABLE.IF AN ALTERNATE METHOD OR PRODUCT IS TO BE USED, CONTACT YOUR APPROVALAUTHORITY FOR REVIEW AND APPROVAL. IF LOCAL STANDARD DETAILS ARE NOT AVAILABLE,USE ONE OF THE TWO TYPES OF TEMPORARY CONCRETE WASHOUTS PROVIDED ON THISDETAIL.
5. DO NOT USE CONCRETE WASHOUTS FOR DEWATERING OR STORING DEFECTIVE CURB ORSIDEWALK SECTIONS. STORMWATER ACCUMULATED WITHIN THE WASHOUT MAY NOT BEPUMPED INTO OR DISCHARGED TO THE STORM DRAIN SYSTEM OR RECEIVING SURFACEWATERS. LIQUID WASTE MUST BE PUMPED OUT AND REMOVED FROM PROJECT.
6. LOCATE WASHOUTS AT LEAST 50 FEET FROM STORM DRAIN INLETS AND SURFACE WATERSUNLESS IT CAN BE SHOWN THAT NO OTHER ALTERNATIVES ARE REASONABLY AVAILABLE. AT A
MINIMUM, INSTALL PROTECTION OF STORM DRAIN INLET(S) CLOSEST TO THE WASHOUTWHICH COULD RECEIVE SPILLS OR OVERFLOW.
7. LOCATE WASHOUTS IN AN EASILY ACCESSIBLE AREA, ON LEVEL GROUND AND INSTALL A STONEENTRANCE PAD IN FRONT OF THE WASHOUT. ADDITIONAL CONTROLS MAY BE REQUIRED BYTHE APPROVING AUTHORITY.
8. INSTALL AT LEAST ONE SIGN DIRECTING CONCRETE TRUCKS TO THE WASHOUT WITHIN THEPROJECT LIMITS. POST SIGNAGE ON THE WASHOUT ITSELF TO IDENTIFY THIS LOCATION.
9. REMOVE LEAVINGS FROM THE WASHOUT WHEN AT APPROXIMATELY 75% CAPACITY TO LIMITOVERFLOW EVENTS. REPLACE THE TARP, SAND BAGS OR OTHER TEMPORARY STRUCTURALCOMPONENTS WHEN NO LONGER FUNCTIONAL. WHEN UTILIZING ALTERNATIVE ORPROPRIETARY PRODUCTS, FOLLOW MANUFACTURER'S INSTRUCTIONS.
10. AT THE COMPLETION OF THE CONCRETE WORK, REMOVE REMAINING LEAVINGS AND DISPOSEOF IN AN APPROVED DISPOSAL FACILITY. FILL PIT, IF APPLICABLE, AND STABILIZE ANYDISTURBANCE CAUSED BY REMOVAL OF WASHOUT.
EARTHEN STOCKPILE MANAGEMENT
1. SHOW STOCKPILE LOCATIONS ON PLANS. LOCATE EARTHEN-MATERIAL STOCKPILE AREAS ATLEAST 50 FEET AWAY FROM STORM DRAIN INLETS, SEDIMENT BASINS, PERIMETER SEDIMENTCONTROLS AND SURFACE WATERS UNLESS IT CAN BE SHOWN NO OTHER ALTERNATIVES AREREASONABLY AVAILABLE.
2. PROTECT STOCKPILE WITH SILT FENCE INSTALLED ALONG TOE OF SLOPE WITH A MINIMUMOFFSET OF FIVE FEET FROM THE TOE OF STOCKPILE.
3. PROVIDE STABLE STONE ACCESS POINT WHEN FEASIBLE.
4. STABILIZE STOCKPILE WITHIN THE TIMEFRAMES PROVIDED ON THIS SHEET AND INACCORDANCE WITH THE APPROVED PLAN AND ANY ADDITIONAL REQUIREMENTS. SOILSTABILIZATION IS DEFINED AS VEGETATIVE, PHYSICAL OR CHEMICAL COVERAGE TECHNIQUESTHAT WILL RESTRAIN ACCELERATED EROSION ON DISTURBED SOILS FOR TEMPORARY ORPERMANENT CONTROL NEEDS.
A
A
BELOW GRADE WASHOUT STRUCTURE
1:1SIDE SLOPE(TYP.)
10 MILPLASTICLINING
3'-
0
"
MIN
.
& X
'
MA
X
.
SECTION A-A
NOT TO SCALE
ABOVE GRADE WASHOUT STRUCTURENOT TO SCALE
PLAN
SECTION B-B
HIGHCOHESIVE &LOW FILTRATIONSOIL BERM
8"
6"
2'
HIGHCOHESIVE &LOW FILTRATIONSOIL BERM1:1 SIDE SLOPE(TYP.)
10 MILPLASTIC LINING
B
B
3'-
0
"
MIN
.
&
X
'
MA
X
.
A
SANDBAGS (TYP.)OR STAPLES
SANDBAGS (TYP.)OR STAPLES
SANDBAGS (TYP.)OR STAPLES
SANDBAGS (TYP.)OR STAPLES
NOTES:1. ACTUAL LOCATION DETERMINED IN FIELD
2. THE CONCRETE WASHOUT STRUCTURES SHALL BEMAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES75% OF THE STRUCTURES CAPACITY.
3.CONCRETE WASHOUT STRUCTURE NEEDS TO BECLEARLY MARKED WITH SIGNAGE NOTING DEVICE.
NOTES:1. ACTUAL LOCATION DETERMINED IN FIELD
2. THE CONCRETE WASHOUT STRUCTURESSHALL BE MAINTAINED WHEN THE LIQUIDAND/OR SOLID REACHES 75% OF THESTRUCTURES CAPACITY TO PROVIDEADEQUATE HOLDING CAPACITY WITH AMINIMUM 12 INCHES OF FREEBOARD.
3.CONCRETE WASHOUT STRUCTURE NEEDSTO BE CLEARLY MARKED WITH SIGNAGENOTING DEVICE.
ONSITE CONCRETE WASHOUT
STRUCTURE WITH LINER
CONCRETEWASHOUT CONCRETEWASHOUT
PLAN
CLEARLY MARKED SIGNAGENOTING DEVICE (18"X24" MIN.)CLEARLY MARKED SIGNAGENOTING DEVICE (18"X24" MIN.)
SILT FENCE
10
'
MI
N
10'MIN
SECTION E: GROUND STABILIZATION
REQUIRED GROUND STABILIZATION TIMEFRAMES
NOTE: AFTER THE PERMANENT CESSATION OF CONSTRUCTION ACTIVITIES, ANY AREAS WITHTEMPORARY GROUND STABILIZATION SHALL BE CONVERTED TO PERMANENT GROUND STABILIZATIONAS SOON AS PRACTICABLE BUT IN NO CASE LONGER THAN 90 CALENDAR DAYS AFTER THE LAST LANDDISTURBING ACTIVITY. TEMPORARY GROUND STABILIZATION SHALL BE MAINTAINED IN A MANNERTO RENDER THE SURFACE STABLE AGAINST ACCELERATED EROSION UNTIL PERMANENT GROUNDSTABILIZATION IS ACHIEVED.
SITE AREA DESCRIPTION TIMEFRAME VARIATIONS
-7 DAYS FOR PERIMETER DIKES, SWALES,DITCHES, PERIMETER SLOPES AND HQW ZONES
-10 DAYS FOR FALLS LAKE WATERSHED UNLESSTHERE IS ZERO SLOPE
STABILIZE WITHIN THISMANY CALENDAR DAYSAFTER CEASING LANDDISTURBANCE
7
7
7
14
NONE
NONE
(a) PERIMETER DIKES,SWALES, DITCHES, ANDPERIMETER SLOPES
(b) HIGH QUALITY WATER
(HQW) ZONES
(c) SLOPES STEEPERTHAN 3:1
IF SLOPES ARE 10' OR LESS IN LENGTH AND ARENOT STEEPER THAN 2:1, 14 DAYS AREALLOWED
(d) SLOPES 3:1 TO 4:1
(e) AREAS WITH SLOPESFLATTER THAN 4:1 14
-7 DAYS FOR SLOPES GREATER THAN 50' INLENGTH AND WITH SLOPES STEEPER THAN4:1
-7 DAYS FOR PERIMETER DIKES, SWALES,DITCHES, PERIMETER SLOPES AND HQWZONES
-10 DAYS FOR FALLS LAKE WATERSHED
EC-02
EROSION AND
SEDIMENT
CONTROL NOTES
(SHEET 2 OF 3)
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
E
S
C
N
O
T
E
S
.
D
W
G
7
/
2
4
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
NCG01 SELF-INSPECTION, RECORDKEEPING AND REPORTING EFFECTIVE: 04/01/19
PART III
SELF-INSPECTION, RECORDKEEPING AND REPORTING
SECTION A: SELF-INSPECTION
SELF-INSPECTIONS ARE REQUIRED DURING NORMAL BUSINESS HOURS IN ACCORDANCE WITH THETABLE BELOW. WHEN ADVERSE WEATHER OR SITE CONDITIONS WOULD CAUSE THE SAFETY OF THEINSPECTION PERSONNEL TO BE IN JEOPARDY, THE INSPECTION MAY BE DELAYED UNTIL THE NEXTBUSINESS DAY ON WHICH IT IS SAFE TO PERFORM THE INSPECTION. IN ADDITION, WHEN A STORMEVENT OF EQUAL TO OR GREATER THAN 1.0 INCH OCCURS OUTSIDE OF NORMAL BUSINESS HOURS,THE SELF-INSPECTION SHALL BE PERFORMED UPON THE COMMENCEMENT OF THE NEXT BUSINESSDAY. ANY TIME WHEN INSPECTIONS WERE DELAYED SHALL BE NOTED IN THE INSPECTION RECORD.
NOTE: THE RAIN INSPECTION RESETS THE REQUIRED 7 CALENDAR DAY INSPECTION REQUIREMENT.
PART III
SELF-INSPECTION, RECORDKEEPING AND REPORTING
SECTION B: RECORDKEEPING
1. E&SC PLAN DOCUMENTATION
THE APPROVED E&SC PLAN AS WELL AS ANY APPROVED DEVIATION SHALL BE KEPT ON THE SITE. THE
APPROVED E&SC PLAN MUST BE KEPT UP-TO-DATE THROUGHOUT THE COVERAGE UNDER THIS
PERMIT. THE FOLLOWING ITEMS PERTAINING TO THE E&SC PLAN SHALL BE KEPT ON SITE AND
AVAILABLE FOR INSPECTION AT ALL TIMES DURING NORMAL BUSINESS HOURS.
2. ADDITIONAL DOCUMENTATION TO BE KEPT ON SITE
IN ADDITION TO THE E&SC PLAN DOCUMENTS ABOVE, THE FOLLOWING ITEMS SHALL BE KEPT ON THE SITE AND AVAILABLE FOR INSPECTORS AT ALL TIMES DURING NORMAL BUSINESS HOURS, UNLESS THE DIVISION PROVIDES A SITE-SPECIFIC EXEMPTION BASED ON UNIQUE SITE CONDITIONS THAT MAKE THIS REQUIREMENT NOT PRACTICAL:
(a) THIS GENERAL PERMIT AS WELL AS THE CERTIFICATE OF COVERAGE, AFTER IT IS RECEIVED.
(b) RECORDS OF INSPECTIONS MADE DURING THE PREVIOUS TWELVE MONTHS. THE PERMITTEESHALL RECORD THE REQUIRED OBSERVATIONS ON THE INSPECTION RECORD FORM PROVIDED BYTHE DIVISION OR A SIMILAR INSPECTION FORM THAT INCLUDES ALL THE REQUIRED ELEMENTS.
USE OF ELECTRONICALLY-AVAILABLE RECORDS IN LIEU OF THE REQUIRED PAPER COPIES WILL BE
ALLOWED IF SHOWN TO PROVIDE EQUAL ACCESS AND UTILITY AS THE HARD-COPY RECORDS.
PART III
SELF-INSPECTION, RECORDKEEPING AND REPORTING
SECTION C: REPORTING
1. OCCURRENCES THAT MUST BE REPORTED
PERMITTEES SHALL REPORT THE FOLLOWING OCCURRENCES:
(a) VISIBLE SEDIMENT DEPOSITION IN A STREAM OR WETLAND.
(b) OIL SPILLS IF:
·THEY ARE 25 GALLONS OR MORE,
·THEY ARE LESS THAN 25 GALLONS BUT CANNOT BE CLEANED UP WITHIN 24 HOURS,
·THEY CAUSE SHEEN ON SURFACE WATERS (REGARDLESS OF VOLUME), OR
·THEY ARE WITHIN 100 FEET OF SURFACE WATERS (REGARDLESS OF VOLUME).
(C) RELEASES OF HAZARDOUS SUBSTANCES IN EXCESS OF REPORTABLE QUANTITIES UNDER SECTION311 OF THE CLEAN WATER ACT (REF: 40 CFR 110.3 AND 40 CFR 117.3) OR SECTION 102 OF
CERCLA (REF: 40 CFR 302.4) OR G.S. 143-215.85.
(d) ANTICIPATED BYPASSES AND UNANTICIPATED BYPASSES.
(e) NONCOMPLIANCE WITH THE CONDITIONS OF THIS PERMIT THAT MAY ENDANGER HEALTH OR THEENVIRONMENT.
2.REPORTING TIMEFRAMES AND OTHER REQUIREMENTS
AFTER A PERMITTEE BECOMES AWARE OF AN OCCURRENCE THAT MUST BE REPORTED, HE SHALLCONTACT THE APPROPRIATE DIVISION REGIONAL OFFICE WITHIN THE TIMEFRAMES AND INACCORDANCE WITH THE OTHER REQUIREMENTS LISTED BELOW. OCCURRENCES OUTSIDE NORMALBUSINESS HOURS MAY ALSO BE REPORTED TO THE DEPARTMENT'S ENVIRONMENTAL EMERGENCYCENTER PERSONNEL AT (800) 858-0368.
3. DOCUMENTATION TO BE RETAINED FOR THREE YEARS ALL DATA USED TO COMPLETE THE E-NOI AND ALL INSPECTION RECORDS SHALL BE MAINTAINED FOR A PERIOD OF THREE YEARS AFTER PROJECT COMPLETION AND MADE AVAILABLE UPON REQUEST. [40 CFR 122.41]
PART II, SECTION G, ITEM (4)
DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT
SEDIMENT BASINS AND TRAPS THAT RECEIVE RUNOFF FROM DRAINAGE AREAS OF ONE ACRE OR MORE SHALL USE OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE SURFACE WHEN THESE DEVICES NEED TO BEDRAWN DOWN FOR MAINTENANCE OR CLOSE OUT UNLESS THIS IS INFEASIBLE. THE CIRCUMSTANCES IN WHICH IT IS NOT FEASIBLE TO WITHDRAW WATER FROM THE SURFACE SHALL BE RARE (FOR EXAMPLE, TIMES WITHEXTENDED COLD WEATHER). NON-SURFACE WITHDRAWALS FROM SEDIMENT BASINS SHALL BE ALLOWED ONLY WHEN ALL OF THE FOLLOWING CRITERIA HAVE BEEN MET:
(a) THE E&SC PLAN AUTHORITY HAS BEEN PROVIDED WITH DOCUMENTATION OF THE NON-SURFACE WITHDRAWAL AND THE SPECIFIC TIME PERIODS OR CONDITIONS IN WHICH IT WILL OCCUR. THE NON-SURFACEWITHDRAWAL
SHALL NOT COMMENCE UNTIL THE E&SC PLAN AUTHORITY HAS APPROVED THESE ITEMS,
(b) THE NON-SURFACE WITHDRAWAL HAS BEEN REPORTED AS AN ANTICIPATED BYPASS IN ACCORDANCE WITH PART III, SECTION C, ITEM (2)(C) AND (D) OF THIS PERMIT,
(c) DEWATERING DISCHARGES ARE TREATED WITH CONTROLS TO MINIMIZE DISCHARGES OF POLLUTANTS FROM STORMWATER THAT IS REMOVED FROM THE SEDIMENT BASIN. EXAMPLES OF APPROPRIATE CONTROLSINCLUDE
PROPERLY SITED, DESIGNED AND MAINTAINED DEWATERING TANKS, WEIR TANKS, AND FILTRATION SYSTEMS,
(d) VEGETATED, UPLAND AREAS OF THE SITES OR A PROPERLY DESIGNED STONE PAD IS USED TO THE EXTENT FEASIBLE AT THE OUTLET OF THE DEWATERING TREATMENT DEVICES DESCRIBED IN ITEM (C) ABOVE,
(e) VELOCITY DISSIPATION DEVICES SUCH AS CHECK DAMS, SEDIMENT TRAPS, AND RIPRAP ARE PROVIDED AT THE DISCHARGE POINTS OF ALL DEWATERING DEVICES, AND
(f) SEDIMENT REMOVED FROM THE DEWATERING TREATMENT DEVICES DESCRIBED IN ITEM (C) ABOVE IS DISPOSED OF IN A MANNER THAT DOES NOT CAUSE DEPOSITION OF SEDIMENT INTO WATERS OF THE UNITEDSTATES.
EC-03
EROSION AND
SEDIMENT
CONTROL NOTES
(SHEET 3 OF 3)
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
E
S
C
N
O
T
E
S
.
D
W
G
7
/
2
4
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
30
24
21
26
26
27
27 28
29
26
27
23
24
23
24
25
23
2
5
26
27
28
22 23 24 25
2021
23
2
4
2
5
2
7
28
29
26
27
18
19
20
21
22
23
24
GAS
GAS
GAS
GAS
GAS
5' S
I
D
E
W
A
L
K
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
INSTALL 322 LF OF
COMPOST SOCK. SEE
EC-13 FOR ADDITIONAL
INFORMATION.
PROPOSED DIVERSION
DIKE
PROPOSED CONSTRUCTION ENTRANCE
LATITUDE: 34 16' 10.84" N
LONGITUDE: 78 54' 41.87" W
INSTALL 184 LF OF SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
N: 191,135.21
E: 2,328,446.62
N: 191,076.62E: 2,328,740.44
N: 190,925.78E: 2,328,636.77
N: 190,961.84
E: 2,328,856.38
10'
N: 191,050.54E: 2,328,764.07
INSTALL
STRUCTURES
S-12 & S-13
INSTALL
15" RCP
SF SF SF
SF
S
F
SF
SF
INSTALL 185 LF OF SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
INSTALL 99 LF OF SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
E
R
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
-
P
H
A
S
E
1
A
.
D
W
G
8
/
2
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
EC-04
EROSION AND
SEDIMENT
CONTROL PLAN -
PHASE 1A
GRAPHIC SCALE IN FEET
0 5025 100
North
LEGEND
SILT FENCE
RIPRAP OUTFALL PROTECTION
BLOCK AND GRAVEL INLET PROTECTION
COMPOST SOCK
CONSTRUCTION AREA LIMITS
SF
NOTES
1. CONTRACTOR IS RESPONSIBLE FOR MAINTAININGPOSITIVE DRAINAGE ON THE PROJECT AT ALL TIMES. IF
DURING SIGNIFICANT RAIN EVENTS AREAS CANNOT BE
MAINTAINED, THE CONTRACTOR SHALL UTILIZE PUMPS AND
DEWATERING BAGS TO MAINTAIN THE SITE.
2. CONTRACTOR TO INSTALL REQUIRED EROSION CONTROL
MEASURES AT EXISTING AND PROPOSED STRUCTURES INORDER TO PROTECT SEDIMENT ENTERING THE PIPENETWORK SYSTEM.
3. EXISTING UTILITIES SHOWN ARE APPROXIMATE AND
SHOULD BE FIELD VERIFIED BY CONTRACTOR.
4. CONTRACTOR SHALL PLACE ALL AGGREGATE FOR PHASE
1A PRIOR TO STARTING PHASE 1B.
05/19/2021 JCW ADDENDUM NO. 1
30
24
21
26
26
27
27 28
29
26
27
23
24
23
24
25
23
2
5
26
27
28
22 23 24 25
2021
23
2
4
2
5
2
7
28
29
26
27
18
19
20
21
22
23
24
GAS
GAS
GAS
GAS
GAS
5' S
I
D
E
W
A
L
K
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVESF
10'
SF
SF
SF SF SF
INSTALL 105 LF OF
ADDITIONAL SILT FENCE.
SEE EC-12 FOR ADDITIONAL
INFORMATION.
PROPOSED DIVERSION
DIKE
PROPOSED CONSTRUCTION ENTRANCE
LATITUDE: 34 16' 10.84" N
LONGITUDE: 78 54' 41.87" W
INSTALL 334 LF OF
COMPOST SOCK. SEE
EC-13 FOR ADDITIONAL
INFORMATION.
184 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
185 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
INSTALL 85 LF OF
ADDITIONAL SILT FENCE.
SEE EC-12 FOR ADDITIONAL
INFORMATION.
INSTALL
STRUCTURE
S-11
INSTALL
18" RCP
N: 191,135.21
E: 2,328,446.62
N: 191,138.03E: 2,328,415.52
N: 191,081.47
E: 2,328,353.60
N: 190,855.44E: 2,328,559.21
N: 190,925.78
E: 2,328,636.77
SF
99 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
S
F
SF
SF
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 5025 100
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
E
R
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
-
P
H
A
S
E
1
B
.
D
W
G
8
/
2
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
EC-05
EROSION AND
SEDIMENT
CONTROL PLAN -
PHASE 1B
LEGEND
SILT FENCE
RIPRAP OUTFALL PROTECTION
BLOCK AND GRAVEL INLET PROTECTION
COMPOST SOCK
CONSTRUCTION AREA LIMITS
AREA OF AGGREGATE PLACEMENT
SF
NOTES
1. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING
POSITIVE DRAINAGE ON THE PROJECT AT ALL TIMES. IFDURING SIGNIFICANT RAIN EVENTS AREAS CANNOT BEMAINTAINED, THE CONTRACTOR SHALL UTILIZE PUMPS ANDDEWATERING BAGS TO MAINTAIN THE SITE.
2. CONTRACTOR TO INSTALL REQUIRED EROSION CONTROL
MEASURES AT EXISTING AND PROPOSED STRUCTURES IN
ORDER TO PROTECT SEDIMENT ENTERING THE PIPE
NETWORK SYSTEM.
3. EXISTING UTILITIES SHOWN ARE APPROXIMATE ANDSHOULD BE FIELD VERIFIED BY CONTRACTOR.
05/19/2021 JCW ADDENDUM NO. 1
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
30
24
21
26
26
27
27 28
29
26
27
23
24
23
24
25
23
2
5
26
27
28
22 23 24 25
2021
23
2
4
2
5
2
7
28
29
26
27
18
19
20
21
22
23
24
GAS
GAS
GAS
GAS
GAS
5' S
I
D
E
W
A
L
K
PROPOSED DIVERSION
DIKE
PROPOSED CONSTRUCTION ENTRANCE
LATITUDE: 34 16' 10.84" N
LONGITUDE: 78 54' 41.87" W
N: 191,081.47E: 2,328,353.60
N: 191,010.97E: 2,328,275.78
N: 190,784.71
E: 2,328,481.21
N: 190,855.29E: 2,328,558.95
INSTALL 365 LF OF
COMPOST SOCK. SEE
EC-13 FOR ADDITIONAL
INFORMATION.
10'
INSTALL 105 LF OF
ADDITIONAL SILT FENCE.
SEE EC-12 FOR ADDITIONAL
INFORMATION.
289 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
INSTALL 134 LF OF
ADDITIONAL SILT FENCE.
SEE EC-12 FOR ADDITIONAL
INFORMATION.
SF
SF
SF
SF
SF
SF SF
SF SF
SF
SF
SF
185 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
185 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
S
F
SF
SF
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
E
R
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
-
P
H
A
S
E
1
C
.
D
W
G
8
/
2
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
EC-06
EROSION AND
SEDIMENT
CONTROL PLAN -
PHASE 1C
GRAPHIC SCALE IN FEET
0 5025 100
North
LEGEND
SILT FENCE
RIPRAP OUTFALL PROTECTION
BLOCK AND GRAVEL INLET PROTECTION
COMPOST SOCK
CONSTRUCTION AREA LIMITS
AREA OF AGGREGATE PLACEMENT
SF
NOTES
1. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING
POSITIVE DRAINAGE ON THE PROJECT AT ALL TIMES. IFDURING SIGNIFICANT RAIN EVENTS AREAS CANNOT BEMAINTAINED, THE CONTRACTOR SHALL UTILIZE PUMPS ANDDEWATERING BAGS TO MAINTAIN THE SITE.
2. CONTRACTOR TO INSTALL REQUIRED EROSION CONTROL
MEASURES AT EXISTING AND PROPOSED STRUCTURES IN
ORDER TO PROTECT SEDIMENT ENTERING THE PIPE
NETWORK SYSTEM.
3. EXISTING UTILITIES SHOWN ARE APPROXIMATE ANDSHOULD BE FIELD VERIFIED BY CONTRACTOR.
05/19/2021 JCW ADDENDUM NO. 1
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
30
24
21
26
26
27
27 28
29
26
27
23
24
23
24
25
23
2
5
26
27
28
22 23 24 25
2021
23
2
4
2
5
2
7
28
29
26
27
18
19
20
21
22
23
24
GAS
GAS
GAS
GAS
GAS
5' S
I
D
E
W
A
L
K
N: 191,010.97E: 2,328,275.78
N: 190,940.48E: 2,328,197.96
N: 190,677.05
E: 2,328,437.13
N: 190,751.72
E: 2,328,507.18
10'
SF
PROPOSED DIVERSION
DIKE
INSTALL 105 LF OF
ADDITIONAL SILT FENCE.
SEE EC-12 FOR ADDITIONAL
INFORMATION.
INSTALL 385 LF OF
COMPOST SOCK. SEE
EC-13 FOR ADDITIONAL
INFORMATION.
INSTALL 125 LF OF
ADDITIONAL SILT FENCE.
SEE EC-12 FOR ADDITIONAL
INFORMATION.
414 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
INSTALL
STRUCTURE
S-7
SF
SF
SF
SF
SF
SF
SF
SF SF
N: 190,784.80
E: 2,328,481.13
PROPOSED CONSTRUCTION ENTRANCE
LATITUDE: 34 16' 10.84" N
LONGITUDE: 78 54' 41.87" W
185 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
S
F
SF
SF
SF SF
SF
SF
SF
290 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
E
R
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
-
P
H
A
S
E
1
D
.
D
W
G
8
/
2
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
EC-07
EROSION AND
SEDIMENT
CONTROL PLAN -
PHASE 1D
GRAPHIC SCALE IN FEET
0 5025 100
North
LEGEND
SILT FENCE
RIPRAP OUTFALL PROTECTION
BLOCK AND GRAVEL INLET PROTECTION
COMPOST SOCK
CONSTRUCTION AREA LIMITS
AREA OF AGGREGATE PLACEMENT
SF
NOTES
1. CONTRACTOR IS RESPONSIBLE FOR MAINTAININGPOSITIVE DRAINAGE ON THE PROJECT AT ALL TIMES. IF
DURING SIGNIFICANT RAIN EVENTS AREAS CANNOT BE
MAINTAINED, THE CONTRACTOR SHALL UTILIZE PUMPS AND
DEWATERING BAGS TO MAINTAIN THE SITE.
2. CONTRACTOR TO INSTALL REQUIRED EROSION CONTROL
MEASURES AT EXISTING AND PROPOSED STRUCTURES INORDER TO PROTECT SEDIMENT ENTERING THE PIPENETWORK SYSTEM.
3. EXISTING UTILITIES SHOWN ARE APPROXIMATE AND
SHOULD BE FIELD VERIFIED BY CONTRACTOR.
4. CONTRACTOR SHALL PLACE ALL AGGREGATE FOR PHASE
1D PRIOR TO STARTING PHASE 1E.
05/19/2021 JCW ADDENDUM NO. 1
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
30
24
21
26
26
27
27 28
29
26
27
23
24
23
24
25
23
2
5
26
27
28
22 23 24 25
2021
23
2
4
2
5
2
7
28
29
26
27
18
19
20
21
22
23
24
GAS
GAS
GAS
GAS
GAS
5' S
I
D
E
W
A
L
K
INSTALL 384 LF OF
COMPOST SOCK. SEE
EC-13 FOR ADDITIONAL
INFORMATION.
N: 190,869.99
E: 2,328,120.14
N: 190,942.33
E: 2,328,196.28
N: 190,605.31
E: 2,328,360.45
N: 190,677.05
E: 2,328,437.13
539 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
10'
INSTALL 105 LF OF
ADDITIONAL SILT FENCE.
SEE EC-12 FOR ADDITIONAL
INFORMATION.
INSTALL 105 LF OF
ADDITIONAL SILT FENCE.
SEE EC-12 FOR ADDITIONAL
INFORMATION.
INSTALL
42" RCP
INSTALL
STRUCTURE
S-14
INSTALL
STRUCTURE
S-6
INSTALL
18" RCP
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF SF
S
F
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
394 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
PROPOSED DIVERSION
DIKE
PROPOSED CONSTRUCTION ENTRANCE
LATITUDE: 34 16' 10.84" N
LONGITUDE: 78 54' 41.87" W
185 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
E
R
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
-
P
H
A
S
E
1
E
.
D
W
G
8
/
3
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
EC-08
EROSION AND
SEDIMENT
CONTROL PLAN -
PHASE 1E
GRAPHIC SCALE IN FEET
0 5025 100
North
LEGEND
SILT FENCE
RIPRAP OUTFALL PROTECTION
BLOCK AND GRAVEL INLET PROTECTION
COMPOST SOCK
CONSTRUCTION AREA LIMITS
AREA OF AGGREGATE PLACEMENT
SF
NOTES
1. CONTRACTOR IS RESPONSIBLE FOR MAINTAININGPOSITIVE DRAINAGE ON THE PROJECT AT ALL TIMES. IF
DURING SIGNIFICANT RAIN EVENTS AREAS CANNOT BE
MAINTAINED, THE CONTRACTOR SHALL UTILIZE PUMPS AND
DEWATERING BAGS TO MAINTAIN THE SITE.
2. CONTRACTOR TO INSTALL REQUIRED EROSION CONTROL
MEASURES AT EXISTING AND PROPOSED STRUCTURES INORDER TO PROTECT SEDIMENT ENTERING THE PIPENETWORK SYSTEM.
3. EXISTING UTILITIES SHOWN ARE APPROXIMATE AND
SHOULD BE FIELD VERIFIED BY CONTRACTOR.
4. CONTRACTOR SHALL PLACE ALL AGGREGATE FOR PHASE
1E PRIOR TO STARTING PHASE 1F.
05/19/2021 JCW ADDENDUM NO. 1
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
30
24
21
26
26
27
27 28
29
26
27
23
24
23
24
25
23
2
5
26
27
28
22 23 24 25
2021
23
2
4
2
5
2
7
28
29
26
27
18
19
20
21
22
23
24
SF
GAS
GAS
GAS
GAS
GAS
5' S
I
D
E
W
A
L
K
N: 190,869.99E: 2,328,120.14
N: 190,799.50
E: 2,328,042.32
N: 190,605.31
E: 2,328,360.45
N: 190,534.82
E: 2,328,282.63
INSTALL 384 LF OF
COMPOST SOCK. SEE
EC-13 FOR ADDITIONAL
INFORMATION.
10'
INSTALL 105 LF OF
ADDITIONAL SILT FENCE.
SEE EC-12 FOR ADDITIONAL
INFORMATION.
644 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
INSTALL 105 LF OF
ADDITIONAL SILT FENCE.
SEE EC-12 FOR ADDITIONAL
INFORMATION.
INSTALL
18" RCP
INSTALL
STRUCTURE
S-3, S-4. & S-5
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF SF
INSTALL
15" RCP
SF
SF
SF
SF
SF
SF
SF
SF
SF
499 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
PROPOSED DIVERSION
DIKE
PROPOSED CONSTRUCTION ENTRANCE
LATITUDE: 34 16' 10.84" N
LONGITUDE: 78 54' 41.87" W
185 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
S
F
SF
SF
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
E
R
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
-
P
H
A
S
E
1
F
.
D
W
G
8
/
3
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
EC-09
EROSION AND
SEDIMENT
CONTROL PLAN -
PHASE 1F
GRAPHIC SCALE IN FEET
0 5025 100
North
LEGEND
SILT FENCE
RIPRAP OUTFALL PROTECTION
BLOCK AND GRAVEL INLET PROTECTION
COMPOST SOCK
CONSTRUCTION AREA LIMITS
AREA OF AGGREGATE PLACEMENT
SF
NOTES
1. CONTRACTOR IS RESPONSIBLE FOR MAINTAININGPOSITIVE DRAINAGE ON THE PROJECT AT ALL TIMES. IF
DURING SIGNIFICANT RAIN EVENTS AREAS CANNOT BE
MAINTAINED, THE CONTRACTOR SHALL UTILIZE PUMPS AND
DEWATERING BAGS TO MAINTAIN THE SITE.
2. CONTRACTOR TO INSTALL REQUIRED EROSION CONTROL
MEASURES AT EXISTING AND PROPOSED STRUCTURES INORDER TO PROTECT SEDIMENT ENTERING THE PIPENETWORK SYSTEM.
3. EXISTING UTILITIES SHOWN ARE APPROXIMATE AND
SHOULD BE FIELD VERIFIED BY CONTRACTOR.
4. CONTRACTOR SHALL PLACE ALL AGGREGATE FOR PHASE
1F PRIOR TO STARTING PHASE 1G.
05/19/2021 JCW ADDENDUM NO. 1
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
30
24
21
26
26
27
27 28
29
26
27
23
24
23
24
25
23
2
5
26
27
28
22 23 24 25
2021
23
2
4
2
5
2
7
28
29
26
27
18
19
20
21
22
23
24
GAS
GAS
GAS
GAS
GAS
5' S
I
D
E
W
A
L
K
N: 190,712.08E: 2,327,945.82
N: 190,799.50
E: 2,328,042.32
N: 190,535.21
E: 2,328,282.32
N: 190,455.88E: 2,328,261.61
N: 190,383.32
E: 2,328,031.18
N: 190,504.10E: 2,328,134.02
749 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
INSTALL 88 LF OF
ADDITIONAL SILT FENCE.
SEE EC-12 FOR ADDITIONAL
INFORMATION.
INSTALL 615 LF OF
ADDITIONAL SILT FENCE.
SEE EC-12 FOR ADDITIONAL
INFORMATION.
INSTALL
STRUCTURES
S-8
INSTALL
24" RCP
INSTALL
30" RCP
INSTALL
30" RCP
INSTALL
30" RCP
INSTALL
STRUCTURES
S-1 & S-2
SFSF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
S
F
N: 190,752.09E: 2,328,506.84
INSTALL 122 LF OF
ADDITIONAL SILT FENCE.
SEE EC-12 FOR ADDITIONAL
INFORMATION.
PROPOSED DIVERSION
DIKE
PROPOSED CONSTRUCTION ENTRANCE
LATITUDE: 34 16' 10.84" N
LONGITUDE: 78 54' 41.87" W
185 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
S
F
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SFSF
S
F
S
F
S
F
S
F
S
F
SF
SF
SF
604 LF OF INSTALLED SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
J.C.W.
J.C.W.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
E
R
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
-
P
H
A
S
E
1
G
.
D
W
G
8
/
3
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
EC-10
EROSION AND
SEDIMENT
CONTROL PLAN -
PHASE 1G
GRAPHIC SCALE IN FEET
0 5025 100
North
LEGEND
SILT FENCE
RIPRAP OUTFALL PROTECTION
BLOCK AND GRAVEL INLET PROTECTION
COMPOST SOCK
CONSTRUCTION AREA LIMITS
AREA OF AGGREGATE PLACEMENT
SF
NOTES
1. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING
POSITIVE DRAINAGE ON THE PROJECT AT ALL TIMES. IFDURING SIGNIFICANT RAIN EVENTS AREAS CANNOT BEMAINTAINED, THE CONTRACTOR SHALL UTILIZE PUMPS ANDDEWATERING BAGS TO MAINTAIN THE SITE.
2. CONTRACTOR TO INSTALL REQUIRED EROSION CONTROL
MEASURES AT EXISTING AND PROPOSED STRUCTURES IN
ORDER TO PROTECT SEDIMENT ENTERING THE PIPE
NETWORK SYSTEM.
3. EXISTING UTILITIES SHOWN ARE APPROXIMATE ANDSHOULD BE FIELD VERIFIED BY CONTRACTOR.
05/19/2021 JCW ADDENDUM NO. 1
GAS
GAS
GAS
GAS
GAS
P\P
P\P
P\P
P\P
G\W G\W
G\WG\WG\WG\W
G\W
OVERHEAD
L
I
N
E
5' S
I
D
E
W
A
L
K
28
28
27
26
26
25
25
29
25
26
27
28
24
21 22 23 24 25
29
27
30
292827
26 27 28
28
29
2
7
2524
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
INSTALL 300 LF OF SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
SF
SF
SF
SF
SF
INSTALL 635 LF OF SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
INSTALL 458 LF OF SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
INSTALL BLOCK AND
GRAVEL INLET PROTECT.
SEE EC-05 FOR DETAIL.
INSTALL BLOCK AND
GRAVEL INLET PROTECT.
SEE EC-05 FOR DETAIL.
S
F
SF
SF
SF
SF
SF SF SF
SF
SF
SF
SF
SF
SF
SF SF SF
SF
SF
SF
SF
SF
S
F
SF
SF
INSTALL 379 LF OF SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
SF
SF
SF
SF
SF
SF
SF
S
F
INSTALL 525 LF OF SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
S
F
S
F
S
F
S
F
S
F
SF
SF
SF
INSTALL 470 LF OF SILT
FENCE. SEE EC-12 FOR
ADDITIONAL INFORMATION.
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 10050 200
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
E
R
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
.
D
W
G
8
/
3
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
EC-11
EROSION AND
SEDIMENT CONTROL
PLAN - PHASE 2
LEGEND
SILT FENCE
RIPRAP OUTFALL PROTECTION
BLOCK AND GRAVEL INLET PROTECTION
SF
NOTES
1. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING
POSITIVE DRAINAGE ON THE PROJECT AT ALL TIMES. IFDURING SIGNIFICANT RAIN EVENTS AREAS CANNOT BEMAINTAINED, THE CONTRACTOR SHALL UTILIZE PUMPS ANDDEWATERING BAGS TO MAINTAIN THE SITE.
2. CONTRACTOR TO INSTALL REQUIRED EROSION CONTROL
MEASURES AT EXISTING AND PROPOSED STRUCTURES IN
ORDER TO PROTECT SEDIMENT ENTERING THE PIPE
NETWORK SYSTEM.
3. EXISTING UTILITIES SHOWN ARE APPROXIMATE ANDSHOULD BE FIELD VERIFIED BY CONTRACTOR.
EC-12
EROSION AND
SEDIMENT
CONTROL DETAILS
(SHEET 1 OF 2)
J.C.W.
1. SEDIMENT ACCUMULATIONS SHALL BE REMOVED WHEN THE DEPOSITS REACH
APPROXIMATELY HALF THE HEIGHT OF THE FABRIC. SHOULD THE FILTER FABRICCOLLAPSE, TEAR, DECOMPOSE, DETERIORATE OR BECOME INEFFECTIVE, IT SHALL BEREPLACED IMMEDIATELY.
2. USE A SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY WEIGHT OF POLYOLEFINS OR
POLYESTER CONFORMING TO ASTM D 6461 AND SHOULD CONTAIN ULTRAVIOLET RAY
INHIBITORS AND STABILIZERS TO PROVIDE A MINIMUM OF 6 MONTHS EXPECTED USABLE
CONSTRUCTION LIFE AT A TEMPERATURE RANGE OF 0° F TO 102° F.
3. FOR REINFORCEMENT OF STANDARD STRENGTH FILTER FABRIC, USE MIN. 14 GAUGE
WIRE FENCE WITH MAX. MESH SPACING OF 6 INCHES.
4. IF EXTRA STRENGTH FABRIC IS UTILIZED (ASTM D 4641), WIRE MESH IS OPTIONAL.
5. POSTS SHALL BE 1.33 LB/LF STEEL WITH MIN. LENGTH OF 5 FEET AND PROJECTIONS TOFACILITATE FASTENING THE FABRIC.
6. ATTACH WIRE MESH TO POST WITH MIN. 4 WIRE OR PLASTIC TIES.
7. ATTACH FILTER FABRIC TO EACH POST WITH MIN. 3 WIRE OR PLASTIC TIES WITHIN THE
TOP 8 INCHES OF THE FABRIC.
8. CONSTRUCT FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH OF THE
BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THEFILTER FABRIC ONLY TO A SUPPORT POST WITH 4 FEET MIN. OVERLAP TO THE NEXTPOST.
9. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING AREA
TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN
PROPERLY STABILIZED.
10. THE USE OF SILT FENCE TO ENCOMPASS OR ENCIRCLE DRAINAGE INLETS AND
STRUCTURES IS PROHIBITED. ANY DAMAGED CAUSED BY THE USE OF SILT FENCE NOT
SPECIFICALLY ALLOWED SHALL BE REPAIRED BY THE CONTRACTOR AT NO COST TO THEOWNER.
11. AT NO TIME SHALL SILT FENCE BE PLACED WITHIN CONCENTRATED FLOW, EXISTING ORPROPOSED DITCHES, OR TEMPORARY DITCHES AND CONVEYANCE MEASURES.
= 36 SQ. IN.OPENING SIZEFABRIC MESH
TEMPORARY SILT FENCE
8' MAX. STANDARD STRENGTH FABRIC WITH WIRE FENCE
SILT FENCE NOTES:
MAX. WIRE
2'
-
0
"
F
A
B
R
I
C
3'
-
0
"
(SEE NOTE 2)
ELEVATION
FILTER FABRIC
ATTACHMENT TO POSTSMESH AND FABRICSEE NOTES REGARDING
2'
-
0
"
ST
E
E
L
PO
S
T
MIDWAY BETWEEN POSTS
ANCHOR FABRIC TO WIREMESH WITH PLASTIC TIES
FILL SLOP
E
36
"
M
I
N
.
WI
D
T
H
FLOW
FA
B
R
I
C
ANCHOR FABRIC AS SHOWN ANDCOMPACT BACKFILL ABOVE IT
SECTION
4"
8"
FILTER FABRIC
WIRE MESH
STEEL POST
GROUNDLINE
EXISTING
6' MAX. EXTRA STRENGTH FABRIC WITHOUT WIRE FENCE
4' MAX
18"
6"
SILT FENCE STONE OUTLET DETAIL
RIP RAP-CLASS B,
FACED WITH # 57
FILTER STONE
NOTES:
1. SILT FENCE STONE OUTLET SHALL BE INSTALLED ALONG PERIMETER OF THE
GRADING LIMITS AT 10O FOOT INTERVALS, LOW SPOTS AND AS ORDERED BY THE
ENGINEER. OUTLETS SHOULD ALSO BE INSTALLED AT OUTFALLS FOR TEMPORARYSLOPE DRAINS OR COMBINATION OF OUTFALLS. DRAINAGE AREAS OF OUTLETSSHOULD BE MINIMIZED AS PRACTICAL.
2. THE COST OF STONE SHALL BE INCIDENTAL TO SILT FENCE.
3. THIS METHOD IS TO BE USED ON BOTH SILT FENCE AND SPECIAL SEDIMENT
CONTROL FENCE.
NOT TO SCALE
NOT TO SCALE
1. A STABILIZED PAD OF RAILROAD BALLAST SHALL BE LOCATED WHERE TRAFFIC WILL ENTER ORLEAVE A CONSTRUCTION SITE ON TO A PUBLIC STREET.
2. STONE TO BE 2" - 3" STONE.
3. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR
FLOWING OF SEDIMENT. STONE AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY
MEASURES USED TO TRAP SEDIMENT.
4. ALL SEDIMENT SPILLED, DROPPED WASHED OR TRACKED ONTO PUBLIC STREETS MUST BE
REMOVED IMMEDIATELY.
5. WHEN NECESSARY, WHEELS MUST BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTERING APUBLIC STREET. WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN AREA STABILIZED WITHCRUSHED STONE WHICH DRAINS INTO AN APPROVED SEDIMENT BASIN.
6. FILTER FABRIC SHALL BE MIRAFI 500 OR EQUAL.
PUBLIC STREET/EXISTING PAVEMENT
STABILIZED CONSTRUCTION ENTRANCE DETAIL
PUBLIC STREET /
EXISTING PAVMENT50' MINIMUM
50' MINIMUM
6" MINIMUM THICKNESS FILTER FABRIC UNDER STONE
EXISTING GROUND
18' MIN.
NOT TO SCALE
J.C.W.
NOTES:
1. LAY ONE BLOCK ON EACH SIDE OF THE STRUCTURE ON ITS SIDE ON THE BOTTOM ROW TO ALLOW POOL
DRAINAGE. THE FOUNDATION SHOULD BE EXCAVATED AT LEAST 2 INCH BELOW THE CREST OF THE STORM
DRAIN. PLACE THE BOTTOM ROW OF THE BLOCK AGAINST THE EDGE OF THE STORM DRAIN FOR LATERAL
SUPPORT AND TO AVOID WASHOUTS WHEN OVERFLOW OCCURS. IF NEEDED, GIVE LATERAL SUPPORT TO
SUBSEQUENT ROWS BY PLACING 2x4 WOOD STUDS THROUGH BLOCK OPENINGS.
2. CAREFULLY FIT HARDWARE CLOTH OR COMPARABLE WIRE MESH WITH 1/2-INCH OPENING OVER ALLBLOCK OPENING TO HOLD GRAVEL IN PLACE.
3. USE CLEAN GRAVEL, 3/4-TO 1/2-INCH IN DIAMETER, PLACED 2 INCHES BELOW THE TOP OF THE BLOCK ON A
2:1 SLOPE OR FLATTER AND SMOOTH IT TO AN EVEN GRADE. DOT #57 WASHED STONE IS RECOMMENDED.
BLOCK AND GRAVEL INLET PROTECTION
NOT TO SCALE
WIRE SCREEN
DEWATERING
16"
SEDIMENT
1' MIN.2' MAX.
TEMPORARYSEDIMENT POOL
2:1 SLOPE, GRAVEL FILTER
DEWATERING CONCRETE BLOCK
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
E
S
C
D
E
T
A
I
L
S
.
D
W
G
8
/
3
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
EC-13
EROSION AND
SEDIMENT
CONTROL DETAILS
(SHEET 2 OF 2)
J.C.W.
J.C.W.
NOT TO SCALE
TEMPORARY DIVERSION DIKE
FLOW
1
2 1
2
SEED AND MULCH CHANNELAFTER DIGGING 6'-0" (TYP.)
NATURALGROUNDLINE
2'-0"MIN.
COMPACTED BERM
SEED AND MULCH
AFTER CONSTRUCTION
12" MIN.
2'
-
6
"
(T
Y
P
.
)
COMPOST SOCK DETAIL
NOT TO SCALE
NOTES
1. COMPOST SOCKS SHALL MEET NCDEQ REQUIREMENTS FROM CHAPTER 6.66 OF THE
NCDEQ EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL.
2. COMPOST SOCKS SHALL BE USED IN DITCHES. THE CONTRACTOR SHALL INSPECTEACH COMPOST SOCK AFTER EACH RAIN EVENT AND PERFORM MAINTENANCE AS
REQUIRED.
3. COMPOST SOCKS SHALL BE 12" IN DIAMETER AND INSTALLED PER THE NCDEQ
REQUIREMENTS.
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
-
E
S
C
D
E
T
A
I
L
S
.
D
W
G
8
/
3
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
5' SIDE
W
A
L
K
CURB LINE
CURB LINE
CURB LINE
CURB LINE
CURB LINE
BACK FLOWPREVENTERWATERMETERCURB L
I
N
E
CURB LINE
GATE
CONSTRUCTIONTRAILER
GRAVELPARKING
PHASE II DA = 4,236,237 SF
97.25 ACRES
11.40 ACRES WETLANDSIMPERV.(85%) = 3,178,694 SF
PHASE I DA = 8,292,980 SF
190.38 ACRESIMPERV.(65%) = 5,342,141 SF122.63 ACRES
HEWLETT DRIVE
AIRPORT BOULEVARD
T
R
A
S
K
D
R
I
V
E
HALL DRIVE
NEW PARKING LOT
PROJECT
AIRPORT
TERMINAL
EXISTING EXTENDED
DRY DETENTION
BASIN
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 400200 800
North
SW-01
OVERALL
STORMWATER
SUMMARY
LEGEND
DRAINAGE AREA
GENERAL STORMWATER NARRATIVE
THE PROPOSED PROJECT IS WITHIN THE DRAINAGE AREA LIMITS "PHASE I AND PHASE II" OFSTORMWATER PERMIT SW8 050547. THE DRAINAGE AREA OUTFALLS TO AN EXISTING EXTENDEDDRY DETENTION BASIN ON THE SOUTH SIDE OF WILMINGTON INTERNATIONAL AIRPORT. THETOTAL DRAINAGE AREA OF PHASE I AND PHASE II IS 287.63 ACRES. AS PER THE MOST CURRENT
SW8 050547 PERMIT MODIFICATION DATED 03/23/2023, THE EXTENDED DRY DETENTION BASIN
HAS AN APPROVED ALLOWABLE IMPERVIOUS AREA OF 8,520,835 SF.
THE PROPOSED PROJECT IS ALSO WITHIN THE LIMITS OF STORMWATER MASTER PERMIT SW8
040836. THE MASTER PERMIT IS TO MAINTAIN AN OVERALL LOW DENSITY FOR THE APPROXIMATE1,621-ACRE AIRPORT TRACT. THE PERMIT ALLOWS NO MORE THAN 486.20 ACRES OFBUILT-UPON-AREA (BUA). AS PER THE MOST CURRENT SW8 040836 PERMIT MODIFICATION DATEDOCTOBER 3, 2019, THERE IS APPROXIMATELY 341.16 ACRES OF EXISTING BUA ON THE AIRPORT
TRACT. CURRENTLY THIS LEAVES APPROXIMATELY 139.72 ACRES OF ALLOWABLE BUA FOR
FUTURE DEVELOPMENT. THIS PROJECT WILL PROPOSE A MODIFICATION TO BOTH STORMWATER
PERMIT SW8 050547 & MASTER PERMIT SW8 040836.
THE NEW PARKING LOT PROJECT OUTFALLS AND IS WITHIN THE DRAINAGE AREA LIMITS OF THE
SW8 050547. THE PROPOSED PARKING LOT HAS A TOTAL BUA OF 231,744 SF. THE PHASE I ANDPHASE II DRAINAGE AREA HAS AN EXISTING BUA OF 7,508,075 SF. A TOTAL BUA FOR THEPOST-CONDITION WILL BE 7,739,819 SF WHICH IS WITHIN THE ALLOWABLE PERMITTED FOR THEEXISTING EXTENDED DRY DETENTION BASIN. NO SURFACE WATERS OR WETLANDS ARE
IMPACTED BY THIS PROJECT. A TABLE FOR BOTH PERMITS WITH DETAILED CALCULATIONS HAS
BEEN PROVIDED BELOW.
STORMWATER PERMIT SUMMARY - SW8 050547
DESCRIPTION AREA (SF)
SW8 050547 TOTAL DRAINAGE AREA - PHASE I AND II 12,529,107
SW8 050547 ALLOWABLE IMPERVIOUS AREA - PHASE I AND
PHASE II 8,520,835
SW8 050547 EXISTING IMPERVIOUS AREA - PHASE I ANDPHASE II 7,508,075
NEW PARKING LOT PROJECT BUA 231,744
SW8 050547 POST-CONDITION IMPERVIOUS AREA - PHASE I
AND PHASE II 7,739,819
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
O
V
E
R
A
L
L
S
T
O
R
M
W
A
T
E
R
S
U
M
M
A
R
Y
.
D
W
G
8
/
8
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
STORMWATER PERMIT SUMMARY - SW8 040836
DESCRIPTION AREA (ACRES)
SW8 040836 ALLOWABLE BUA 486.20
SW8 040836 EXISTING BUA 341.160
NEW PARKING LOT PROJECT BUA 5.32
SW8 040836 POST-CONDITION BUA 346.480
**
**
**PER STORMWATER PERMIT MODIFICATION SW8 040836 DATED OCTOBER 03, 2019
*PER STORMWATER PERMIT MODIFICATION SW8 050547 DATED MARCH 23, 2023
*
*
30
24
21
26
26
27
27 28
29
26
27
23
24
23
24
25
23
2
5
26
27
28
22 23 24 25
2021
23
2
4
2
5
2
7
28
29
26
27
18
19
20
21
22
23
24
GAS
GAS
GAS
GAS
GAS
GAS
GAS
5' S
I
D
E
W
A
L
K
HEWLETT DRIVE
AIRPORT BOULEVARD
AL
L
E
G
H
E
N
Y
D
R
I
V
E
TR
A
S
K
D
R
I
V
E
DOLAN DRIVE
AVIATION DRIVE
TO: S-1A = 0.37
C = 0.71
TO: S-2
A = 0.41
C = 0.86
TO: S-3
A = 0.46
C = 0.82
TO: S-6A = 0.40C = 0.84
TO: S-7
A = 0.47
C = 0.84
TO: S-11A = 0.38
C = 0.84
TO: S-12A = 0.32C = 0.82 TO: S-13A = 0.15C = 0.80
TO: SI-8A = 1.27C = 0.74
TO: S
-
1
8
A = 0
.
1
5
C = 0
.
8
0
TO: S
-
1
7
A = 0
.
1
2
C = 0
.
8
2
TO: S
-
4
A = 0
.
2
9
C = 0
.
8
2
TO: S
-
5
A = 0
.
1
5
C = 0
.
8
2
TO: S-16
A = 2.62
C = 0.38
TO: S-14
A = 5.58
C = 0.55
S-1
S-2
S-4
S-5
S-6
S-7
S-13
S-12
S-11
S-14
S-15
S-16
S-17
S-18
S-19
S-8
S-3
MH-1
MH-2
TO: S-19
A = 1.02
C = 0.42
28
28
27
26
26
25
25
29
25
26
27
28
24
21 22 23 24 25
29
27
30
292827
26 27 28
28
29
2
7
2524
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 5025 100
North
SW-02
PROPOSED
DRAINAGE DIVIDES
LEGEND
DRAINAGE AREA
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
D
R
A
I
N
A
G
E
D
I
V
I
D
E
S
.
D
W
G
8
/
1
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
NOTES
1. ALL PROPOSED STORM PIPES HAVE BEEN DESIGNEDFOR A 25-YEAR STORM AS PER NEW HANOVERREQUIREMENTS. PIPE CAPACITIES WERE CALCULATED
USING NOAA PRECIPITATION DATA AND THE RATIONAL
METHOD.
2. SEE STORM PROFILES ON SHEET C-10 AND C-11.
AIRPORT BOU
L
E
V
A
R
D
J.C.W.
J.C.W.
GRAPHIC SCALE IN FEET
0 5025 100
North
NEW PARKING LOT
PROJECT
2022.0286.01
SHEET NUMBER
PROJECT NO.
AUGUST 2023
G.M.W.
G.M.W.
NO.DATE BY DESCRIPTION
DRAWN BY:
APPROVED BY:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
REVISIONS:
WILMINGTON
INTERNATIONAL
AIRPORT
WILMINGTON, NC
ATTENTION:
THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARYINFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC.,FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE.WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANYDISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, INWHOLE OR IN PART, IS STRICTLY PROHIBITED
P:
\
2
0
2
2
\
2
0
2
2
.
0
2
8
6
.
0
1
-
I
L
M
-
E
N
T
R
A
N
C
E
R
O
A
D
A
N
D
N
E
W
P
A
R
K
I
N
G
L
O
T
P
R
O
J
E
C
T
\
0
2
2
0
2
2
.
0
2
8
6
.
0
1
E
N
G
I
N
E
E
R
I
N
G
\
C
A
D
\
2
0
2
2
.
0
2
8
6
.
0
1
_
O
V
E
R
A
L
L
L
A
N
D
S
C
A
P
E
P
L
A
N
.
D
W
G
8
/
1
1
/
2
0
2
3
N.C. C-2450STATE LICENSE #
KEY PLAN
AS NOTED
NOT RELEASED FOR
CONSTRUCTION
ENGINEERS & PLANNERSAVCON, INC.
6230 CAROLINA BEACH ROAD WILMINGTON, NC 28412
www.avconinc.com
OFFICE: (910) 685-7113
L-01
OVERALL
LANDSCAPE PLAN
ARTICLE 5 - PERFORMANCE STANDARDS
BASED ON NEW HANOVER COUNTY, NORTH CAROLINA UNIFIED DEVELOPMENT ORDINANCE
SECTION 5.4.5.C STANDARDS FOR PARKING LOT INTERIORS
·LANDSCAPE AREAS IN THE INTERIOR OF PARKING LOTS SHALL BE EIGHT PERCENT OF THETOTAL AREA TO BE USED FOR PARKING.- 201,438 SF (GROSS PARKING LOT PAVED AREA) X 0.08 = 16,115 SF- 16,560 SF LANDSCAPE PROVIDED
·REQUIRED TO BE LANDSCAPED- 1 SHADE/CANOPY TREE
- 16,560 SF / 144 SF = 115 TREES- 115 CANOPY TREES PROVIDED
·LANDSCAPE ISLAND SHALL BE A MINIMUM OF 12' FROM CURB TO CURB.
·ONE PLANTED TREE SHALL BE REQUIRED FOR EVERY 144 SQUARE FEET ROUNDED TO THE
NEXT LOWEST WHOLE NUMBER.
·AT LEAST 75% OF TREES REQUIRED FOR INTERIOR LANDSCAPING SHALL BE OF ASHADE/CANOPY TREE.
LEGEND
CANOPY/SHADE TREE
PLANT SCHEDULE
TREES QTY BOTANICAL / COMMON NAME CAL SIZE
CANOPY 115 BETULA NIGRA / RIVER BIRCH 2"CAL 12'-14'
CANOPY/SHADE TREE DETAIL
GENERAL LANDSCAPE NOTES
1. MATERIALS LIST WAS PREPARED FOR ESTIMATING PURPOSES, CONTRACTOR SHALL MAKEOWN QUANTITY TAKE-OFF USING DRAWINGS AND SPECIFICATIONS TO DETERMINEQUANTITIES TO HIS SATISFACTION, REPORTING PROMPTLY ANY DISCREPANCIES WHICHMAY EFFECT BIDDING.
2. ROOT TYPES MAY BE FREELY SUBSTITUTED IN CASE OF BALLED AND BURLAPPED ORCONTAINER GROWN. ALL PLANT MATERIAL MUST ADHERE TO ANSI Z60 1-2004 (AMERICANSTANDARD FOR NURSERY STOCK) SPECIFICATIONS FOR ROOT BALLS AND CONTAINERSIZES.
3. CONTRACTOR TO VERIFY THAT ALL PLANT MATERIALS ARE AVAILABLE AS SPECIFIED
WHEN BID/PROPOSAL IS SUBMITTED.
4. UNLESS SPECIFICALLY NOTED, ALL PLANTS SHALL BE OF SPECIMEN QUALITY,EXCEPTIONALLY HEAVY, SYMMETRICAL, AND SO TRAINED OR FAVOR IN DEVELOPMENTAND APPEARANCE AS TO BE UNQUESTIONABLY AND OUTSTANDINGLY SUPERIOR IN FORM,
COMPACTNESS AND SYMMETRY. THEY SHALL BE SOUND, HEALTHY, VIGOROUS, WELLBRANCHED AND DENSELY FOLIATED WHEN IN LEAF; FREE OF DISEASE AND INSECTS, EGGS
OR LARVAE; AND SHALL HAVE HEALTHY, WELL-DEVELOPED ROOT SYSTEMS. THEY SHALLBE FREE FROM PHYSICAL DAMAGE OR OTHER CONDITIONS THAT WOULD PREVENT
VIGOROUS GROWTH.
5. SUBSTITUTIONS OF PLANT MATERIALS WILL NOT BE PERMITTED UNLESS AUTHORIZED IN
WRITING BY THE ENGINEER. IF PROOF IS SUBMITTED IN WRITING THAT A PLANT SPECIFIEDIS NOT OBTAINABLE, CONSIDERATION WILL BE GIVEN TO THE NEAREST AVAILABLE SIZE OR
SIMILAR VARIETY, WITH CORRESPONDING ADJUSTMENT OF THE CONTRACT PRICE.
6. PLANT BED SHALL BE TESTED FOR PH AND AMENDED PRIOR TO INSTALLATION.
7. ALL PLANT MATERIAL SHALL CONFORM TO STANDARD SET FORTH BY "AMERICAN
STANDARDS FOR NURSERY STOCK" ANSI Z60-2004 PUBLISHED BY THE AMERICAN NURSERYAND LANDSCAPE ASSOCIATION.
8. ALL PLANT MATERIAL SHALL BE PROTECTED DURING TRANSPORT AND DELIVERY TO JOB
SITE WITH SHADE CLOTH OR OTHER ACCEPTABLE MEANS OF WINDBURN PREVENTION.
9. ANY SUBSTITUTIONS IN SIZE AND/OR PLANT MATERIAL MUST BE APPROVED BY THE
ENGINEER BEFORE PLANTING CAN BEGIN.
10. CONTRACTOR SHALL ASSURE DRAINAGE AND PERCOLATION OF PLANTING PITS PRIOR TOINSTALLATION OF PLANT MATERIAL. CONTRACTOR IS RESPONSIBLE FOR THE
REPLACEMENT OF ALL PLANTS LOST DUE TO INADEQUATE DRAINAGE CONDITIONS.
11. TURF GRASS SHALL BE PLANTED AFTER ALL PLANTS ARE INSTALLED AND MULCHED. SEED
AND/OR SOD BED PREPARATIONS BY MEANS OF PULVERIZATION TO LOOSEN SOIL.SMOOTH AND FINE GRADE AREA REMOVING ANY ROCKS, ROOTS, TRASH, AND CLODS
OVER ENTIRE AREA.
12. CONTRACTOR TO MAINTAIN THE PLANTINGS AND CONTROL WEEDS IN MULCH AREASTHROUGH THE DURATION OF CONSTRUCTION UNTIL FINAL ACCEPTANCE.