Loading...
Application MaterialsPage 1 of 5 Variance Application – Updated 05-2021 NEW HANOVER COUNTY_____________________ DEPARTMENT OF PLANNING & LAND USE 230 Government Center Drive, Suite 110 Wilmington, North Carolina 28403 Telephone (910) 798-7165 FAX (910) 798-7053 planningdevelopment.nhcgov.com ZONING & SUBDIVISION VARIANCE APPLICATION This application form must be completed as part of a request for a zoning and/or subdivision variance. The application submitted through the county’s online COAST portal. The main procedural steps in the submittal and review of applications for a variance are outlined in the flowchart below. More specific submittal and review requirements, as well as the standards to be applied in reviewing the application, are set out in Section 10.3.11 of the Unified Development Ordinance. Public Hearing Procedures (Optional) Pre-Application Conference (Optional) Community Information Meeting 1 Application Submittal & Acceptance 2 Planning Director Review & Staff Report 3 Public Hearing Scheduling & Notification  Advisory Body Review & Action 4 Board of Adjustment Hearing & Decision 5 Post-Decision Limitations and Actions 1. Applicant and Property Owner Information Applicant/Agent Name Owner Name (if different from Applicant/Agent) Company Company/Owner Name 2 Address Address City, State, Zip City, State, Zip Phone Phone Email Email Cindee Wolf Design Solutions P.O. Box 7221 Wilmington, NC 28406 910-620-2374 cwolf@lobodemar.biz Castle Hayne, NC 28429 Paul E. & Deanne R. Meadows 4717 Indian Corn Trail meadowsd@earthlink.net 910-617-5105 (Contact: Rick Meadows) Page 2 of 5 Variance Application – Updated 05-2021 2. Subject Property Information Address/Location Parcel Identification Number(s) Total Parcel(s) Acreage Existing Zoning and Use(s) 3. Proposed Variance Narrative Subject Zoning Regulation, Chapter and Section In the space below, please provide a narrative of the application (attach additional pages if necessary). 4737 Castle Hayne Road 322112.95.1866 [R01700-002-007-000] RA / Commercial 0.94 ac. Page 3 of 5 Variance Application – Updated 05-2021 CRITERIA REQUIRED FOR APPROVAL OF A VARIANCE The Board of Adjustment may grant a variance if it finds that strict application of the ordinance results in an unnecessary hardship for the applicant, and if the variance is consistent with the spirit, purpose, and intent of the ordinance. The applicant must explain, with reference to attached plans (where applicable), how the proposed use meets these required findings (attach additional pages if necessary). 1. Unnecessary hardship would result from strict application of the ordinance. It shall not be necessary to demonstrate that, in the absence of the variance, no reasonable use can be made of the property. 2. The hardship results from conditions that are peculiar to the property, such as location, size or topography. Hardship resulting from personal circumstances, as well as hardships resulting from conditions that area common to the neighborhood or general public, may not be the basis for granting a variance. A hardship would result from strict application of the prescribed setback because it would require demolition of the existing structure, and new construction to meet the larger setback. The hardship results from the desire for adaptive re-use of an existing structure. The property is currently zoned for residential use, and the structure is conforming to that zoning district's setback. However, the proposed rezoning to use the structure for commercial use would create a non-conforming situation. Page 4 of 5 Variance Application – Updated 05-2021 3. The hardship did not result from actions taken by the applicant or the property owner. The act of purchasing property with knowledge that circumstances exist that may justify the granting of a variance shall not be regarded as a self-created hardship. 4. The requested variance is consistent with the spirit, purpose and intent of the ordinance, such that public safety is secured, and substantial justice is achieved. Again, the hardship to the property owner would be the necessity to remove a perfectly good structure, rather than adapting it for a different use. Approval of the requested variance would allow the adaptive re-use of an existing structure. The existing side property setback meets all building code regulations, and that yard will include a vegetated buffer for the visual screening and physical separation from the adjacent residential use. Allowing some latitude to this specific requirement, on this particular parcel, would not adversely affect the spirit, purpose or intent of the Ordinance, nor pose a public safety issue. Approval of a variance for a reduced setback would provide substantial justice for the property owner to pursue reasonable use of the existing structure. Son d e y R o a d Cape Fear Township / New Hanover County / North Carolina (No Scale) Vicinity Map 3. Current Zoning District: RA 2. Tract Area: 40,844 s.f.± (0.94 ac.) 1. New Hanover County Parcel No.: General Notes: 4. Comprehensive Plan Classification: Site Project No.:Property Address: 4737 Castle Hayne Road Development Notes: the New Hanover County Zoning Ordinance. 1. All development shall be in accordance with Hanover County regulations. 2. Project shall comply with all Federal, State & New PRELI M I N A R Y Not Fo r C o n s t r u c t i o n Design Solutions P.O. Box 7221 Wilmington, NC 28406 Tel. 910-620-2374 Scale: Date: Revisons: 23-33 1'' = 20' 01/16/24 N E S W S N W E Community Mixed-Use 322112.95.1866 Concept Plan Zoning District Development Data: 200 Graphic Scale 10 402010 Owner / Developer: [PID R1700-002-007-000] Tract Area - 40,844 s.f.± (0.94 ac.) Total Building Area - 8,500 s.f.± Parking - (@ 2.5 spaces / 1000 s.f. GFA) Min. Spaces Req'd. = 9 ** Spaces Prov'd. = 10 ** (2 garage spaces) Approximate Surface Coverage - Total - 8,500 s.f.± (38.7%) Max. Proposed Building Height - 1-Story / 20' Meadows CommercialConditional Proposed District - (CZD) B-2 Paul & Deanne Meadows 4717 Indian Corn Trail Castle Hayne, NC 28429 Rooftop -3,500 s.f.± Parking Area -4,300 s.f.± 2. This property is not impacted by any AEC. 3. There is no evidence of Conservation Overlay resources. 4. This site is not impacted by any recognized historic or archeological significance. 5. No cemeteries were evidenced on the site. 6. Existing regulated trees have been field located. No "Specimen" trees were identified. Tree protection 7. There is no evidence of jurisdictional wetlands. 8. There is no evidence of endangered species or habitat issues on the site. Site Inventory Notes: 9. This tract is not impacted by any Special Flood Hazard 10. The site runoff will flow into the Prince George 1. Soils: On (Onslow loamy fine sand) & and mitigation - if necessary - will be completed during detailed design & permitting. Area as evidenced on FEMA Map 3720323100K, dated August 28, 2018. Off-site Driveway - 700 s.f.± Case No.: Creek watershed. Pn (Pantego loam) Utility Notes: 1. Water service will be provided by a private, on-site well. Sanitary sewer service is provided by a gas & telephone shall be installed underground. 3. Solid waste disposal will be by dumpster pickup by 2. All utility services, such as electric power, CATV, private on-site septic system. private contractor / hauler. NC H W Y 1 1 7 PAR M E L E R D SODN E Y R D Cas t l e H a y n e R o a d ( U . S . H w y . 1 1 7 ) Sonde y R o a d / S . R . 1 3 3 4 (Va r i a b l e W i d t h P u b l i c R / W ) 23 23 21 21 WaterOak N 66° 2 4 ' 2 5 " W 1 5 8 . 9 0 ' S 36 ° 3 8 ' 3 5 " W 2 4 4 . 5 7 ' N 2 8 ° 2 7 ' 3 5 " E 2 2 6 . 9 3 ' S 69°58 ' 2 5 " E 1 9 5 . 2 5 ' (50' R / W ) 22 21 22 23 19 19 20 20 48'' Live Oak 32'' DoorO/H (1, 7 5 0 s . f . ) Spa c e 35' 50' DoorO/H 35' New " F l e x " (1, 7 5 0 s . f . ) Spa c e New " F l e x " Existing Gravel Existing Gravel Exis t i n g She d Existing Shed Existing Garage Existing Office Existing Shed 0.8' 7.0' 20' T r a n s i t i o n a l B u f f e r 35' R e a r S e t b a c k 20' T r a n s i t i o n a l B u f f e r 30' Si d e S e t b a c k Existing -5,000 s.f.± Proposed New -3,500 s.f.± Existing -18,889 s.f.± Proposed New -21,956 s.f.± 21. 7 '