Loading...
3-6-2024 TRC Agenda Full1 TECHNICAL REVIEW COMMITTEE AGENDA March 6, 2024 New Hanover County’s Technical Review Committee (TRC) will meet Wednesday, March 6, 2024 at 2:00 p.m. to discuss the below items. PLEASE NOTE: This meeting will be conducted remotely via teleconference. Interested parties can contact the Planning and Land Use Department at 910-798-7165 for more information. Item 1: Tarin Woods II Road Infrastructure – Major Subdivision – SUBPP-24-0001 Request by James Yopp of River Road Construction for TRC review for new roads being installed in the Tarin Woods expansion located at 5831 Carolina Beach Road. The site is 36.98 acres and is zoned R-15. The engineer is Rodney Wright with CSD Engineering (rodney@csd-engineering.com) . The case planner is Robert Farrell (rfarrell@nhcgov.com, 910-798-7164). Item 2: Monkey Junction Townhomes – Major Subdivision – SUBPP-24-0002 Request by Adam Sosne of MHMJ, LLC for 54 townhomes and 146 apartment units located at 5322 Carolina Beach Road. This site went through a rezoning in 2023, Z23-17. They were originally approved for 35 townhomes and 165 apartment units, but have requested an administrative minor deviation for an up to 10% adjustment in housing type. They are requesting TRC review for the current maximum housing type adjustment amount under this minor deviation. The site is 12.68 acres and is zoned (CZD) RMF-M. The engineer is Garry Pape with GSP consulting (gpape@gsp-consulting.com). The case planner is Zach Dickerson (zdickerson@nhcgov.com, 910-798- 7450). Item 3: Blue Clay Business Park Flex Space – Commercial Site Plan – SITECN-24-000004 Request by Sean Banester of Francini, Inc. for 96,100 sq ft of flex space in the Blue Clay Industrial Park, located at 4011 Blue Clay Rd. The site is 5.9 acres and is zoned I-2. The engineer is Rick Moore with McKim & Creed (RAMoore@mckimcreed.com). The case planner is Wendell Biddle (wbiddle@nhcgov.com, 910-798-7068) Item 4: *Sketch Plan Review* Sidbury Rd Major Subdivision Request by Mary Catherine Santos with McKim and Creed for a sketch plan review of a concept plan for major residential subdivision on Sidbury Road. The area is currently zoned R-15, and the Parcel IDs are R01900-002-003-000 and R02700-001-049-000. Don’t forget to change header to the same as the subject line – TRC Review Page | 1 To: James Yopp, james@rockfordpartners.net From: Robert Farrell Development Review Supervisor Date: March 6, 2024 TRC Review PID#: R07600-004-052-000 Egov# SUBPP-24-0001 Subject: Tarin Woods – Infrastructure Preliminary Plat – TRC Review The following comments have been received for the March 6, 2024, TRC meeting. Additional comments may be made upon further review of subsequent revisions. Please note: following the TRC meeting, a revised preliminary plan addressing each of the below items must be resubmitted prior to receiving preliminary plan approval. NHC Planning, Robert Farrell 910-798-7164 1. General Comments – a. Will the connection to Rosa Parks Drive be full access? b. Is there an anticipated timeline for a permanent cul-de-sac for this section of road? i. c. Be aware future residential development will require sidewalks. Don’t forget to change header to the same as the subject line – TRC Review Page | 2 2. UDO Section 3.3.1, Superseding District Standards & Setbacks a. Project is for road infrastructure only. No residential development proposed. 3. UDO Section 5.1 Parking and Loading a. Project is for road infrastructure only. No residential development proposed. 4. UDO Section 5.2. Traffic, Access, & Connectivity a. See NCDOT comments for information on driveway access requirements. 5. UDO Section 5.3 Tree Retention a. Existing tree removal permits on file. No additional trees proposed for removal for this project. 6. UDO Section 5.4 Landscaping and Buffering a. Project is for road infrastructure only. No residential development proposed. 7. UDO Section 5.5 Exterior Lighting a. Be aware, future street lighting or other on-site lighting must meet the requirements of Section 5.5 of the UDO. 8. UDO Section 5.6 Signs a. Street signs including street name signs must comply with the minimum requirements of the New Hanover County Addressing Ordinance and minimum NCDOT street sign design. 9. UDO Section 5.7 Conservation Resources. a. The New Hanover County Conservation Resources Map indicates there are Pocosin conservation resources on the property. b. Conservation requirements will apply to the project and any future development of the site: 6.07 acres of street right-of-way x 0.5 Conservation Space Factor = 3.03 acres of minimum conservation space. 10. UDO Section 5.8 Open Space Requirements a. Open space not required for right-of-way and road infrastructure. Future development will require open space meeting minimum requirements of Section 5.8. 11. UDO Article 6, Subdivision Design and Improvements a. Label the length of all roads on the map. b. Label the diameter of the temporary cul-de-sac at the end of Sweet Gum Drive. c. 13 links / 8 notes = 1.62 connectivity ratio. Connectivity ratio is above the minimum required 1.45 ratio. d. Label whether any traffic calming devices are proposed in the development. e. Note: Sidewalks may be required on one or both sides of the streets depending on the type of future development of site or if rezoned or allowed additional density by the Board of Commissioners through a public hearing or quasi-judicial process. 12. UDO Article 9: Flood Damage Prevention a. Property is not in a Special Flood Hazard Area. Don’t forget to change header to the same as the subject line – TRC Review Page | 3 NHC Fire Services, David Stone 910-798-7458 1. Fire service sees no issue with the road design. NHC Engineering, Galen Jamison 910-798-7072 1. A land disturbing and a stormwater permit issued by the County are required for this project. Please submit for permits as the design is completed. 2. Please contact the State for the stormwater permit requirements. 3. Please verify the sediment basin to the south is not covered by another stormwater permit. The county has no record of it being permitted for stormwater. NHC Environmental Health, Dustin Fenske 910-798-6732 1. Proposed development and infrastructure do not violate setbacks to any surrounding property’s well or septic systems. NHC Addressing, Katherine May 910-798-7443 1. Please contact me with street name proposals prior to TRC approval. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 1. CFPUA TRC Comments provided are preliminary comments only. 2. Utility Plan review required by CFPUA. CFPUA is moving toward becoming paperless. When ready to submit plan review package, upload all documents to: https://www.cfpua.org/FormCenter/Engineering-3/Engineering-Plan-Review-103. 3. CFPUA water and sewer available through mainline extensions. 4. Capacity is dependent on the analysis of the pipe collection system (gravity and force mains). 5. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE Application Form and a Preliminary Plan, this determination does not guarantee capacity. 6. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the Authority. WMPO, Jamar Johnson 910-473-5130 See attached. Don’t forget to change header to the same as the subject line – TRC Review Page | 4 Brad Shaver USACOE Brad.E.Shaver@usace.army.mil 1. Tarin Woods II has an existing jurisdictional determination (JD) which includes several jurisdictional tributaries. It appears these tributaries will be impacted therefore a permit is anticipated. Comments not received at this time from: NCDOT, Nick Drees 910-398-9100 Emergency Services & E911, Steve Still NCDEQ, Chad Coburn New Hanover Soil & Water, Dru Harrison USACE, Rachel Capito NCDEMLR, Dan Sams DCM, Tanya Pietila MEMORANDUM To: New Hanover County Technical Review Committee Date: 2/23/24 Subject: Tarin Woods Subdivision Road Infrastructure Comments: • Provide turning templates of the largest design vehicle to access the roads. NCDOT Projects: TIP Projects in the Area: N/A WMPO 2045 Projects: N/A New Hanover County CTP: N/A TIA: Development has a revised TIA approval with conditions letter dated March 26, 2020. All improvements are required of the development. Monkey Junction Townhomes and Apartments, -5322 Carolina Beach Road – Preliminary Plan – TRC Review Page | 1 To: Adam G Sosne, MHMJ, LLC – adam@mcadamshomes.net From: Zachary Dickerson – Development Review Senior Planner Date: March 6th TRC Review PID#: R07606-003-002-000, R07600-006-042-000 Egov# SUBPP-24-0002 Subject: Monkey Junction Townhomes and Apartments- Preliminary Site Plan Review The following comments have been received for the March 6th, 2024, TRC meeting. Additional comments may be made upon further review of subsequent revisions. Please note: following the TRC meeting, a revised preliminary plan addressing each of the below items must be resubmitted prior to receiving preliminary plan approval. Planning, Zachary Dickerson 910-798-7450 1. General Comments a. This case is subject to the conditions agreed to by the applicant for case Z23-17. b. Please add the following conditions to the site plan, these can be in the site data table or off to the side on their own: i. Buildings will have a maximum height of three stories. c. Originally, the approved plans permitted 35 townhomes and 165 apartment units. Using the administrative adjustments allowed in the UDO for a minor deviation from that approved concept plan, a 10% shift in housing type is allowed. This development may have up to a maximum of 55 townhomes and down to a maximum of 145 apartment units. d. The minor deviation meets the standards of Section 10.3.3.7.b, Minor Deviations. Final written approval will be included in the TRC approval letter. Separate approval of the minor deviation may be provided at applicant’s request. 2. UDO Section 5.1, Parking and Offstreet Loading a. Row-style housing requires two parking spaces per unit. b. Does each unit have its own driveway with two spaces or will these be garages underneath? Monkey Junction Townhomes and Apartments, -5322 Carolina Beach Road – Preliminary Plan – TRC Review Page | 2 c. Is there any visitor parking planned for the townhomes or apartments? If so, please note that on the site plan. d. Please show location of mailbox kiosk and pull-off area on site plan. 3. UDO Section 5.2, Traffic, Access and Connectivity a. Please show sight triangles at point of entry on Carolina Beach Road. b. Will there be any traffic calming devices in this development? If so, please show them on the site plan. c. Please consider including pedestrian crossings towards the area where residents will be crossing to the trash/recycling area. d. Will there be a pedestrian crossing congruent with the sidewalk for the stream onsite? e. Does the sidewalk extend to the property line with the Townes at Park Place? It does not appear so (see green), but with the intent for interconnectivity 4. UDO Section 5.3, Tree Retention a. For the trees slated to be removed, please submit a tree removal permit. b. Link to permit here: https://www.nhcgov.com/DocumentCenter/View/1239/Tree- Removal-Permit-PDF 5. UDO Section 5.4, Landscaping and Buffering a. A Type A: Opaque buffer is required where the site abuts residential uses. b. Please submit a landscape plan for transitional buffers, parking lot interior landscaping, foundation plantings for the apartment buildings, and street yard. c. Please note that 15 trees are required to be planted per acre disturbed per UDO Section 5.4.2.B. Trees retained on site can count towards this requirement. 12.53 acres * 15 trees = 188 trees. Per the tree retention table on page 3 of the site plan, 198 trees are being retained. This requirement is met. 6. UDO Section 5.5, Lighting a. Is any lighting proposed for this development? b. Please note a lighting plan is not required at time of TRC approval. See below excerpt from Section 5.5.3: i. Information about the exterior lighting for the site that demonstrates compliance with the standards in this section shall be submitted in conjunction with an application for site plan approval (Section 10.3.6, Site Plan) or zoning compliance approval (Section 10.3.8, Zoning Compliance Approval), whichever comes first, approved no later than at time of construction plan approval. 7. UDO Section 5.6, Signs a. If there are any new signs proposed for this development, please apply for sign permits prior to installation. Monkey Junction Townhomes and Apartments, -5322 Carolina Beach Road – Preliminary Plan – TRC Review Page | 3 8. UDO Section 5.7, Conservation Resources a. Per the New Hanover County Conservation Resource Overlay map, the rear/western portion this site is located within the Pocosin Conservation Resource. b. However, a Jurisdictional Determination from the Army Corps of Engineers Determined that this site no longer contains wetlands. 9. UDO Section 5.8, Open Space Requirements a. Are the below clouded areas intended as open space? If so, please label them as such. b. I noted these are marked as such on sheet C-1 but it would be helpful for it to be marked on all pages. 10. UDO Article 6: Subdivision Design and Improvements a. It appears that the link to node ratio, outlined in UDO Section 6.2.2.7.g is not sufficient for this development. Per this section, the link to node ratio shall not be less than 1.4. Using the definitions of links and nodes as outlined in this section, I have shown the number of each on this plan below: b. Per my calculations, this shows 14 links and 12 nodes for a ratio of 1.17. c. I think the issue here is the number of T-intersections and dead-ends. The roads in the site will need to be reconfigured to achieve at least the minimum ratio. Monkey Junction Townhomes and Apartments, -5322 Carolina Beach Road – Preliminary Plan – TRC Review Page | 4 NHC Fire Services, David Stone 910-798-7458 Please submit a civil plan showing locations of proposed fire hydrants prior to TRC. 1. The complete TRC/Site plans comments from New Hanover County Fire staff shall be submitted along with the building plans for review to New Hanover County Building Safety. This shall include the complete set of civil plans. Failure to submit the comments or complete set of civil plans will result in a resubmittal for review for verification of compliance. 2. Per NCFC 507.1, Provide an Engineered fire flow analysis report in accordance with the fire code and Appendix B to include pertinent information. Fire flow test shall be conducted in accordance with NFPA 291 and NCFC 507.4 3. All new structures larger than 7,500 square feet must comply with Section 510 of the NC Fire code. An Emergency Responder Radio Coverage (ERRC) survey must be conducted, and results given to the Building Safety Fire Plan Reviewer. All buildings that are more than one story, underground, windowless or buildings with a basement must complete an ERRC survey. (It is highly recommended that a pre-construction survey be conducted, however a pre-construction survey is not required). 4. Fire apparatus access roads are required at time of construction. They are to be capable of handling the weight of fire apparatus and be passable in all weather conditions. Fire apparatus access roads are to be a minimum of 20 feet wide (Chapter 5), unless there are fire hydrants installed along the roadway then minimum is 26 feet wide (Appendix D). The fire code official may increase this width as necessary based on potential for fire apparatus response. Dead end roads greater than 150 feet in length shall require an approved means for fire apparatus to turn around (Chapter 5 and Appendix D). Fire apparatus access roads shall provide a clear vertical clearance of 14 feet including trees, canopies, bridges, etc. (Chapter 5 requirement is 13 feet 6 inches, however AHJ requires 14 feet based on local apparatus). 5. Street and road signs are required, temporary signs during construction are acceptable as long as they are legible and weather resistant. (Chapter 5). 6. Fire apparatus access roads that access commercial buildings greater than 30 feet in height are to be a minimum of 26 feet wide, be capable of handling the weight of aerial fire apparatus (100,000 lbs.) and be passable in all weather conditions. 7. Parking shall not be allowed on either side of the above-mentioned roadway. If roadside parking is desired the minimum road width shall be increased, contact the fire code official for further information. No Parking signs shall be a minimum of 12 inches wide and 18 inches tall. Commercial buildings shall have fire lanes marked (Chapter 5) 8. Fire apparatus access roads shall provide access to within 150 feet of each side of the first-floor exterior walls unless the building is equipped throughout with an approved automatic sprinkler system then the distance increases to 200 feet (Chapter 5). If these options are not selected, please contact the fire code official and fire department for guidance. 9. Gates on fire apparatus access roads are discouraged due to the delay in response. If a gated access is deemed necessary it shall be either staffed with personnel 24 hours per day every day, 365 days of the year or must include KNOX key bypass switch and siren activation (both). (Chapter 5). Monkey Junction Townhomes and Apartments, -5322 Carolina Beach Road – Preliminary Plan – TRC Review Page | 5 10. Traffic calming devices are highly discouraged due to the delay in response. Speed bumps/humps are prohibited. Requests for other traffic calming devices must be evaluated during the Technical Review (TRC). 11. Fire lanes shall be a minimum of 18 feet wide and 14 feet vertical clearance feet including trees, canopies, bridges, etc. and must be marked. 12. Key Boxes (KNOX Boxes) a. Required if the structure is required to have a fire alarm system or automatic sprinkler system. b. Knox Box required at front (main) entrance, above eye level. Larger facilities may require more than one. c. The customer may order online from Knox. 13. Premises identification is required. Address and or unit numbers are required on the street side as well as unit identification on rear access doors. Letters and Numbers shall not be less than 6 inches tall and ¾ inches wide; must be weather resistant and contrasting in color to their background. (Chapter 5). Buildings constructed under the 2018 code shall require additional signage per Appendix J. 14. Rooms containing controls for HVAC, fire sprinkler risers, fire alarm control panels, or other fire detection/protection equipment must be identified with signage (Chapter 5). 15. Fire Command Centers are required for high rise occupancies (Chapters 5 and 9) 16. Generator and solar installations shall be in accordance with Chapter 6. 17. If facilities or buildings brought into or built within the jurisdiction are more than 400 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrant and mains shall be provided. 18. If the approved water supply is not capable of supplying the required fire flow for fire protection a private system shall be engineered to meet the required fire flow for both automatic sprinkler systems and fire hydrants. 19. Fire Hydrants d. All fire hydrants shall have a 5 ¼ inch barrel, a 5 ¼ inch valve opening, two 2 ½ inch NST side discharges and a 5 inch pumper nozzle with a 5 inch STORZ connection. Further information on the technical specifications is available from the fire code official or Cape Fear Public Utility Authority. e. All fire hydrants shall be installed so they are visible from the fire apparatus access road with unobstructed access and a clear space no less than 36 inches in all directions. They shall be protected from vehicle impact by curbing, guard posts or other means approved by the fire code official. They shall be oriented with the large discharge facing the nearest street. All discharges shall meet the NFPA requirements for distance above grade. f. Fire hydrants in general residential areas shall be installed so that all insured properties are within 500 feet of a hydrant (hydrant spacing approximately 1000 feet apart along a fire apparatus access road, installed at intersections where possible). The first fire hydrant should be installed at or near the entrance to the residential area. Monkey Junction Townhomes and Apartments, -5322 Carolina Beach Road – Preliminary Plan – TRC Review Page | 6 g. Fire hydrants in mixed use and commercial areas shall be installed so that all insured properties are within 250 feet of a hydrant (hydrant spacing approximately 500 feet apart along fire apparatus access roads and preferably located at intersections when possible). h. Fire hydrants for industrial and manufacturing areas shall be installed so that all structures are within 250 feet of a fire hydrant; distances may be adjusted more or less based on approval of the fire code official and based on the hazards present. i. Additional fire hydrants may be required by the fire code official based on the type of hazard or use of the protected structure. (Appendix C) j. Fire hydrants should be located 50 feet or more from the structure they protect. 20. Fire Department Connections (FDC) k. Fire Department connections shall utilize 5-inch Storz connections with a 30 degree down angle. Remote FDC’s are discouraged. l. A fire hydrant shall be located no less than 50 feet from the structure and no greater than 100 feet from the fire department connection. For buildings with multiple fire department connections, each one shall have a dedicated fire hydrant. m. The fire department connection shall be located so that the fire apparatus and the hoses connecting it to the fire hydrant and to the fire department connection do not obstruct access to the buildings for other fire apparatus. n. Fire department connections shall not be obstructed by fences, bushes, dumpsters, utilities or vehicles. o. Fire department connections are to be unobstructed with 36 inches clearance to both sides and 78 inches vertically. p. An audible/visual device indicating water flow or fire alarm activation shall be located above the fire department connection. q. The fire department connection shall be labeled with code compliant signage indicating the type of connection and where more than one fire department connection exists additional signage is required to indicate the area protected. NHC Engineering, Galen Jamison 910-798-7072 1. A land disturbing and a stormwater permit issued by the County are required for this project in addition to the State stormwater permit. Please submit for permits as the design is completed. 2. The offsite drainage coming from the south that be routed through the site shall be placed in a revised public drainage easement sized in accordance with NHC Stormwater Manual. Construction within this offsite drainage conveyance measure that will be maintained by the county will need to be observed during construction by Stormwater Services and a turnover meeting scheduled once the system is ready to be conveyed to the county. Please add a plan note to ensure county construction observation and a turnover meeting occurs. Note, should the applicant elect to maintain the conveyance measures themselves, the POA covenants shall indicate the operation and maintenance roles and responsibilities for the conveyance measure. Monkey Junction Townhomes and Apartments, -5322 Carolina Beach Road – Preliminary Plan – TRC Review Page | 7 NHC Environmental Health, Dustin Fenske 910-798-6732 1. Site plan reflects connection to public water and sewer. Proposed infrastructure does not violate setbacks to surrounding properties well or septic systems. NHC Addressing, Katherine May 910-798-7443 1. Four new street names will be required. Please contact me with street name proposals prior to TRC approval. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 1. CFPUA TRC Comments provided are preliminary comments only. 2. Utility Plan review required by CFPUA. CFPUA is moving toward becoming paperless. When ready to submit plan review package, upload all documents to https://www.cfpua.org/FormCenter/Engineering-3/Engineering-Plan-Review-103. 3. CFPUA water and sewer available through mainline extensions. 4. Water and sewer within Townes at Park Place is private. 5. Capacity is dependent on the analysis of the pipe collection system (gravity and force mains). 6. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE Application Form and a Preliminary Plan, this determination does not guarantee capacity. 7. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the Authority. NCDOT, Nick Drees 910-343-3915 1. See attached. WMPO, Jamar Johnson 910-473-5130 1. See attached. Army Corps of Engineers, Brad Shaver 910-251-4611 1. Has a JD and permitting is anticipated to cross the on-site stream. Comments not received at this time from: Emergency Services & E911, Steve Still NCDEQ, Chad Coburn New Hanover Soil & Water, Dru Harrison USACE, Rachel Capito NCDEMLR, Dan Sams DCM, Tanya Pietila STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION ROY COOPER J.R. “JOEY” HOPKINS GOVERNOR SECRETARY Mailing Address: NC DEPARTMENT OF TRANSPORTATION DISTRICT 3 ENGINEER’S OFFICE 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 04-11-03 COURIER Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Memorandum To: New Hanover County Technical Review Committee Date: February 28, 2024 Subject: Monkey Junction Townhomes_5322 Carolina Beach Road ________________________________________________________________________ These are preliminary comments and are based on the plans as submitted for the proposed site. They are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. General Comments: The approved TIA allows for 35 townhomes and 165 apartment units (proposed change to 54 townhomes and 146 apartment units), the request will need to be approved by the WMPO. Required Roadway Improvements per the approved TIA: • US 421 (Carolina Beach Rd) at SR 1247 (Antoinette Dr)/Industrial Park Dr (Signalized Intersection): o Construct a northbound left turn lane on SR 1247 (Antoinette Dr) with 200 feet of storage, appropriate full-width deceleration and taper. o Provide a four-section FYA for the northbound and southbound left turn lanes. o Modify the signal plan to accommodate the above improvements. • SR1575 (Service Road) at Site Access 1 (Existing Unsignalized Intersection at car wash exit): o Construct Site Access 7 (northbound approach) with one ingress lane and one egress lane, connecting to the existing car wash access. • SR 1247 (Antionette Dr) at Site Access 2 (Proposed Unsignalized Intersection): o Construct Site Access 2 (westbound approach) with an internal protected stem of 50 feet, measured from the right-of-way line, and one ingress lane and one egress lane. o Provide stop control for the westbound approach. A signal agreement is required due to the signal modifications. NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT Online Portal.https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx An NCDOT Driveway Permit is required. Submit plans in accordance with pages 14 and 15 of the Policy on Street and Driveway Access to North Carolina Highways to include access locations within 500’ of the proposed access on both sides of the State Road. Submit to the local NCDOT District Engineer’s Office. • Refer to the NCDOT checklist for submittal requirements (Documents, details, and plans). • Refer to the NCDOT Roadway Design Manual for help with the design of any required roadway improvements. A NCDOT Encroachment Agreement is required for any utility connections or installations within NCDOT right-of-way. Site Plan Comments: No plans were submitted that showed the design of the driveway or required roadway improvements. • Refer to the included NCDOT Checklist and the additional comments below. Sight Triangles and Sight Distance: o No obstructions shall be placed within the NCDOT sight triangles. • Show and label the appropriate sight distances. o No obstructions shall be placed within the stopping sight distance. This development is located within the proposed TIP U-5863. With that in mind, any accesses that conflict with the planned transportation infrastructure may be modified and/or removed and there shall not be any compensation made by NCDOT. You can coordinate with the district office with any questions 910-398-9100. NCDOT | Division 3 | District 3 Project Name:_____________________________ Date:_______________ Applicant Checklist NCDOT Checklist Driveway Application Process and Site Plan Requirements ALL APPLICATIONS SHALL BE ACCOMPANIED BY COMPLETE AND DETAILED SITE PLANS THAT ADHERE TO THE POLICIES LISTED IN THE POLICY ON STREET AND DRIVEWAY ACCESS TO NORTH CAROLINA HIGHWAYS AND THIS DOCUMENT. FAILURE TO ADHERE TO THESE POLICIES WILL RESULT IN THE RETURN OF THE APPLICATION TO THE APPLICANT FOR REVISION. ***THE NCDOT WILL NOT BEGIN THE REVIEW PROCESS ON INCOMPLETE APPLICATIONS*** Electronic Pre-Submittals In an effort to save time and resources, we are happy to provide an initial assessment of a driveway permit submittal’s plans via email to identify any major issues up front. This initial assessment can be followed up with a submittal of one digital copy of the plans along with all other required documents. All Permit applications shall be submitted through the online portal https://connect.ncdot.gov/site/Permits/Pages/default.aspx In the notify email section of the portal application please include the District Office email (Div3Dist3@ncdot.gov). See the last pages for further instruction. Online resources: •NCDOT Policy on Street and Driveway Access to North Carolina Highways: https://connect.ncdot.gov/projects/Roadway/RoadwayDesignAdministrativeDocuments/Policy%20on%20Street%20an d%20Driveway%20Access.pdf •NCDOT Policies and Procedures for Accommodating Utilities on Highway Rights of Way: https://connect.ncdot.gov/municipalities/Utilities/Pages/UtilitiesManuals.aspx •Electronic Forms Database: https://connect.ncdot.gov/Pages/default.aspx 1) a.Cover Letter Include contact information for applicant and engineer, including email address, mailing address, and phone number. Include the parcel number(s), description of all phases of the development and future land uses to be served by the permit, and a description of the adjoining land owned or controlled by the applicant. b.NCDOT Street and Driveway Access Permit Application (form downloadable via link below) https://connect.ncdot.gov/resources/BusinessForms/TEB-65-04.doc c.$50.00 Inspection Fee Per Access Point Attach to Permit Application form (not applicable for municipalities, churches, and schools) d.NPDES Stormwater Permit Compliance Certification (form downloadable via link below) https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/NPDESstatement.doc e.Verification of Compliance with Environmental Regulations (form downloadable via link below) https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/VCER-1.pdf f.Site Plans (to include the “Master Plan” of a tract even if only a small portion is being developed first) Additional site plan requirement details can be found in section 2 of this document. g.Design Plan Requirements for projects involving roadway improvements If roadway improvements are required as part of the permit, then roadway plans, pavement marking plans,signing plans, and traffic control plans will be required - See Section 6 for more information Y N n/a Engineering Studies The applicant may be required by the District Engineer to submit studies based on, but not limited to, the parameters outlined herein. If study requirements of the local government agency are more restrictive than the NCDOT requirements, then local government requirements will govern. However, this does not imply that the NCDOT is obligated to approve entrance designs that are too constrictive to allow smooth and safe traffic flow. All studies including, but not limited to, Traffic Impact Analyses (TIA), traffic signal studies, and drainage studies, must be prepared under the direct charge of and sealed by a North Carolina licensed Professional Engineer. Section 1: Requi red Documents |Required documents to accompany all Initial Driveway Application Submittals Please note that these are the minimum requirements of all driveway permit applications. All required documentation shall be submitted through the online portal as PDF files, with the exception of the Performance and Indemnity Bond and the $50 Inspection Fee(s), these should be mailed or delivered to 5501 Barbados Blvd, Castle Hayne, NC 28429. If a Traffic Impact Analysis and/or roadway improvements are deemed necessary as a condition of the permit, there may be additional submittal materials required. State of North Carolina | Department of Transportation | Division 3 | District 3 5501 Barbados Blvd, Castle Hayne, NC 28429 Form Updated 10/15/2021 (910) 398-9100 T NCDOT Permit #___________________ Y N n/a Section 1: Required Documents (continued) 2)Required documents to accompany all Driveway Applications PRIOR TO FINAL APPROVAL a.Site Plans One (1) digital copy (PDF) unless otherwise requested by the District Office. Additional site plan requirement details can be found in section 2 of this document. b.Performance and Indemnity Bond Information/Forms See last page of document for bond information and forms c.Performance and Indemnity Bond Amount 100% of the cost of the work within NCDOT Right-of-Way (R/W) based on the attached estimate determined by the applicant's engineer and approved by the District Engineer. Bond hold letter required for for municipalities, churches, and schools. See pages 101-105 in the Policies and Procedures for Accommodating Utilities on Highway Rights of Way for acceptable bond types d.Radius Encroachment Letter (if applicable) If driveway radius encroaches on the frontage of an adjacent property, a Radius Encroachment will be required e.Hold Harmless Letter (if applicable) If the Permit is within the limits of an active NCDOT project, a Hold Harmless letter from the NCDOT contractor will be required. If the project is in preconstruction, coordinate with the Department's Project Development Unit Section 2: General Site Plan Requirements | All site plans shall include and show, at a minimum, the items listed below Page numbers reference the NCDOT Policy on Street and Driveway Access to North Carolina Highways 1)Drawn to a scale of 20, 30, 40, or 50 feet per inch and the scale shall be shown 2)North arrow, vicinity map, date of plan, and date of most-recent revision if applicable 3)Contact information of applicant and engineer, including mailing address, phone number, and email address 4)Show R/W lines, highway control of access, and property lines 5)All existing utilities (including handholes) and easements 6)R/W width 7)Existing posted speed limit(s) and design speed limit(s) 8)Show all property lines, intersections, signals, signal loops, railroads, or crossovers within 500’ in all directions of the property lines of the proposed development 9)Show location of sidewalks, crosswalks, greenways, multi-use paths, curb ramps, railroads, bus stops, and any other relevant transportation facilities in the development area 10)Include a plan sheet showing full site build-out and land use 11)Buildings shown with “gross leasable area” 12)Width of property frontage 13)Distance from R/W to buildings and gasoline service islands 14)Distance from R/W to existing/proposed Edge of Pavement (EOP) (pages 32 & 34) 15)All streams, bridges, retaining walls, signs, or other fixed objects such as trees, utility poles, traffic signals, etc. Section 3: Driveway Plan Requirements | All driveway plans shall include and show, at a minimum, the items listed below 1)Provide comprehensive survey within the existing R/W on both sides of the road for a distance of 500’ in all directions from the development’s property lines. Provide additional hydraulic survey data to the nearest storm water inlet/outlet including ditch lines and storm water pipes, if located outside of the 500' distance. 2)Lane configurations and widths of all existing and proposed driveways, roadways, and adjacent roadways 3)All driveway widths (2-way: 20’ minimum, 36’ maximum | 1-way: 12’ minimum, 24’ maximum | with island: 14'ingress, 18' egress) (pages 50 & 77) 4)Driveway Profile - In shoulder sections, maintain minimum 2% fall from edge of travel way for required shoulder width distance Primary: 8’ minimum | Secondary: 6’ minimum 5)All existing and/or proposed driveway radii (20’ minimum, 50’ maximum, 30’ typical) (pages 34 & 51) In curb and gutter sections, use City of Wilmington flare (SD 3-03.3) - (see attached) In shoulder sections, show grades at the EOP and centerline 6)No curbing is allowed within NCDOT R/W along shoulder sections except as part of a driveway island (page 31) 7)Driveway angles of approach to existing roadway (90° preferred, 75°-90° required for 2-way driveways, 45°-90° allowed for right-in/right-out on a case-by-case basis) (page 51) 8)Driveway Profile (pages 42- 43) Y N n/a Y N n/a □□ □□ □ □ Y N n/a Y N n/a Y N n/a Y N n/a Section 3: Driveway Plan Requirements (continued) 9)Driveway Pavement Cross Section (to be in place from EOP to edge of R/W) Asphalt: 8” ABC stone and 1.5” S9.5B Concrete: 6” of concrete 10)Driveway Offset (driveway EOP to property line; page 75): Minimum: 20’ 11)Corner Clearance (radius point to radius point; page 52)Minimum: 50’ Desirable: 100’ or Municipal std. 12)Minimum 10’x70’ sight triangles at driveways (measured from and along the R/W line) (page 31) 13)Sight Distance (length of sight-distance in both directions shown for each driveway; pages 27-29) 14)Driveways should be aligned with existing opposing driveways or correct offset should be provided (pages 40-41) 15)Distance between driveways being requested (if applicable; page 51) 16)Minimum internal storage areas with specified queues (pages 31-33) 17)Minimum protected driveway stem(s) provided and indicated (pages 33-34) 18)Indicate any gated entrances (100’ minimum setback from R/W required) - traffic queuing study may be required | Section 6: Roadway Plan Requirements If off-site improvements are required, roadway plans shall show, at a minimum, the items below 1)Full width typical sections must be shown (paved shoulders to match the typical section of the adjacent roadway) 2)Minimum Asphalt Typical Section (for turn lanes and/or paved shoulders) Adjacent recently-completed or upcoming TIP projects w/ different typical sections may supersede those below •Primary Routes (US & NC) and Secondary Routes with Annual Average Daily Traffic (AADT) ≥10,000 5.5” B25.0C, 3” I19.0C, 1.5” S9.5C; any overlay of existing pavement is to be a minimum of 1.5” S9.5C •Secondary Routes with AADT<10,000 5.5” B25.0C, 1.5” S9.5B; any overlay of existing pavement is to be a minimum of 1.5” S9.5B 3)Pavement overlay is required if modification of existing pavement markings and/or lanes is necessary The grinding of pavement markings will not be allowed 4)Shoulder Widths (Paved + Unpaved) Primary: 8’ minimum | Secondary: 6’ minimum 5)Ditch Slopes - front and back slopes - minimum 3:1 or flatter 6)Indicate existing roadway grade 7)All taper lengths and deceleration lengths should be appropriately designed for the given design speed (page 78) 8)All turn lanes should be designed according to the Driveway Manual and Roadway Standard Drawings (page 79) See 1205.04 Sheets 1 & 2 and 1205.05 Sheet 1 of the Roadway Standard Drawings for details 9)Pavement marking and signing plans are required - plans must be approved by Division Traffic Services 10)Traffic control plans are required - Detailed phasing plans may be required based on project type and location 11)New and/or revised signal plans must be included for new installations and if signal modifications are required All signal plans must be reviewed and approved by Division Traffic Services and the Signal Design Unit. A Traffic Agreement must be completed to facilitate the review. Contact Division Traffic Services at (910) 341-2200. | Section 4: Drainag e Requirements All drainage features on NCDOT Right-of-Way shall adhere to, at a minimum, the items listed below Section 5: Internal Circ ulation Requirements |All internal circulation details shall adhere to, at a minimum, the items listed below 1)Interior driveway channelization stems Minimum 100’ from the ROW or at the discretion of the District Engineer 2)Traffic flow pattern 3)Traffic control devices 4)Pavement Markings Y N n/a Y N n /a Y N n/a Y N n/a Y N n/a Y N n/a Y N n/a Y N n/a 1)Pipe Cover Minimums (measured from top of pipe to subgrade) High Density Polyethylene (HDPE): 24” | Corrugated Aluminum (CAP): 12” | Reinforced Concrete (RCP): 12” 2)Pipe End Treatment (see Roadway Design Manual 5-20, B-2) Pipes ≤24" on multilane highways posted above 45mph require Parallel Pipe End Sections See 310.02 and 310.04 of the Roadway Standard Drawings for details Pipes >30" on multilane highways posted above 45mph require guardrail Pipes ≥36" require an endwall on the inlet end 3)All proposed Drainage is to be provided inside existing R/W. Otherwise, additional R/W or a permanently dedicated drainage easement will be required to accommodate the proposed project drainage 4)All sizes, types, and invert elevations of existing/proposed pipes and drainage structures must be shown(see Sec.3 #1 for survey requirements) 5)Provide spot elevations along frontage of driveway (at EOP and centerline) 6)Provide grades and spot elevations for existing and proposed ditches 7)Show how drainage will be accommodated along property frontage(District Engineer may require applicant to provide drainage calculations when warranted) C/L EOTEOP P/L R/WR/W R/W EOP EOP EOP EOP NTS R/W P/L DRAINAGE FLOW DRAINAGE FLOW DRAINAGE FLOW SHOULDER WIDTH SHOULDER WIDTH SHOULDER WIDTH SHOULDER WIDTH S IGHT T R IANGLE 10 ' BY 70 'S I GHT T R I AN G L E10' B Y 70' DRIVEWAY RR MIN. 30'MIN. 30' NO ROADWAY IMPROVEMENT COMMERCIAL DRIVEWAY WITH NORMAL CROWN ROADWAY 6" LOWER THAN THE EDGE OF PAVEMENTMIN 2% FALL AWAY or 20' AWAY FROM THE PROPERTY LINEDRIVEWAY SHALL BE LOCATED AT LEAST PIPE/TYPE/SIZE WIDTH CON CR ET E /ASP HA LT LOCAL NAME ROAD POSTED SPEED ( ) MPH WIDTH WIDTHSR NUMBER SITE ADDRESS:TAX PARCEL # 20191115 PARALLEL END S.D. 310.02 INVERT ELEVATION PARALLEL END S.D. 310.02 INVERT ELEVATION 20' AWAY FROM THE PROPERTY LINEDRIVEWAY SHALL BE LOCATED AT LEAST OR 500' OF XYZ SURVEY DATA PAST THE PROPERT LINENEAREST OUTFALL ELEVATION OR 500' OF XYZ SURVEY DATA PAST THE PROPERT LINENEAREST OUTFALL ELEVATION Roadway Design Manual At Grade INTERSECTIONS May 2023 Part I General Design Information | 8-22 Figure 8-10 Recommended Treatment for Turn Lanes Note: Make every attempt possible to use the desirable deceleration length. It can be shortened as needed but shall not be less than the minimum. Coordinate with NCDOT and get approval on anything less than the desirable deceleration length. MEMORANDUM To: New Hanover County Technical Review Committee Date: 2/23/24 Subject: Monkey Junction Townhomes 5322 Carolina Beach Rd Comments: • Show ADA detectable warning pads at curb ramps at access aisles and crosswalks. • Consider revising the intersection to have better pedestrian access instead of sending pedestrians into the roadway. Those with a vision disability or use a wheelchair would not be able to traverse the intersection safely. • Label all radii on the plans. • Label curve radius of the travel ways. • Include plan sheets of required offsite improvements per the TIA approval with conditions letter. NCDOT Projects: TIP Projects in the Area: N/A WMPO 2045 Projects: N/A 2 New Hanover County CTP: N/A TIA: Development has a TIA approval with conditions letter dated July 13, 2023. All improvements listed are required of the development. 4011 Blue Clay Road – Francini at Blue Clay Rd – Commercial Site Plan – TRC Review Page | 1 To: Sean Banester, Francini, Inc. Marble & Granite – sean@francinimarble.com Richared A. Moore, PE McKim & Creed, Inc. – ramoore@mckimcreed.com From: Wendell E. Biddle Development Review Associate Planner Date: March 6th, 2024, TRC Review PID#: R02600-002-005-000 Egov# SITECN-24-000004 Subject: 4011 Blue Clay Road – Francini at Blue Clay Rd – Commercial Site Plan – TRC Review The following comments have been received for the March 6th, 2024, TRC meeting. Additional comments may be made upon further review of subsequent revisions. Please note: following the TRC meeting, a revised preliminary plan addressing each of the below items must be resubmitted prior to receiving preliminary plan approval. NHC Planning, W. E. Biddle 910-798-7068 1. General Comments – a. Invoice INV-00116823 pending payment. b. Please note that elevations must be tied to North American Vertical Datum of 1988 (NAVD 88) and horizontal coordinates must be tied to the North Carolina Grid System. c. Please note and address that the site plan details multiple images in which there are disparities between the orientation of the parcel and the compass’ north bearing. d. The site plan and application’s request is for a 96,100 SF commercial building within an I- 2, Heavy Industrial zoning district. The structure is to be leased by tenants and the use is to be considered flex space. i. Sheet C3.0 details the building’s dimensions to be 110’ x 310’ with a product of 96,100 square feet. Please clarify the difference between structure’s dimensions and the proposed square footage. 2. UDO Section 5.1 Parking and Loading a. Parking is sufficient per the UDO. b. Please detail the loading bays and their corresponding dimensions on sheet C3.0. 4011 Blue Clay Road – Francini at Blue Clay Rd – Commercial Site Plan – TRC Review Page | 2 3. UDO Section 5.2. Traffic, Access, & Connectivity a. Please note which access is primary and which is secondary on the site plan. b. Please include sight triangles. c. Please note that the roads are publicly dedicated. In order for the roads to be adopted by DOT in the future, driveway access to them will be required to meet DOT driveway standards. d. Please note on the site plan that “No building permit for any structure shall be issued which requires NCDOT approval for a Driveway Permit until NCDOT has issued the permit approval. Evidence of approval shall accompany the application for the building permit.” 4. UDO Section 5.3 Tree Retention a. The site has been cleared of trees. No further tree removal permits required. 5. UDO Section 5.4 Landscaping and Buffering a. Per UDO 5.4.2.B, the required 15 trees per acre is specifically for the amount of disturbed acreage vs the number of total acres on lot. While we on the Development Review Team encourage the extra trees, please note that the required amount of trees is based off the 187,148 square feet of impervious ground cover which equates to 4.29 acres- requiring a minimum of 60 trees total. i. Should team decide to reduce total number of trees in light of comment 5.a, please provide updated landscape plan and plant schedule to reflect as much. b. Please detail the required trees for the interior parking lot landscaping. 6. UDO Section 5.5 Exterior Lighting a. Is any lighting proposed for the development? b. Please note that with the latest update to the UDO, a lighting plan is not required at time of TRC approval. See below excerpt from Section 5.5.3: i. Information about the exterior lighting for the site that demonstrates compliance with the standards in this section shall be submitted in conjunction with an application for site plan approval (Section 10.3.6, Site Plan) or zoning compliance approval (Section 10.3.8, Zoning Compliance Approval), whichever comes first, approved no later than at time of construction plan approval. c. When the lighting plan is submitted, please ensure that the foot candles from the streetlights at the lot lines do not exceed 0.5, as the adjacent land is residential. 7. UDO Section 5.6 Signs a. Please note that all signs are subject to Section 5.6 of the UDO. b. Please submit for sign permits prior to installation. 8. UDO Section 5.7 Conservation Resources. a. No further requirements necessary for the site’s conservation space. 4011 Blue Clay Road – Francini at Blue Clay Rd – Commercial Site Plan – TRC Review Page | 3 NHC Fire Services, Ray Griswold 910-798-7448 1. 34,100 sq. ft warehouse What type storage is proposed, including storage height(s)? Where is the FDC located? A 3rd fire hydrant will be required, based on size of structure. Would like to see on loading dock side to the rear of property and unobstructed by parking Will High rack/ Piled Storage be use? If so all fire code requirements shall be met. A fire Flow Analysis shall be conducted a Section 510 study will have to be conducted Knox Boxes will have to be provided, minimum one at the Riser Room and one at the nearest exit for the fire alarm panel/ front entrance. Appendix J of the fire code shall be followed – Building information Signage. The TRC Plan review comments as sent to Planning shall be followed. Plan shows “existing Fire Hydrant”. It has not been installed yet. It is part of the count. NHC Engineering, Galen Jamison 910-798-7072 1. A revision to County stormwater permit STMW-22-0031 is required for this project. The submission shall include the latest plans and calculations for the original permitted system. 2. Please contact the State for the stormwater permit modification requirements. 3. A land disturbing permit issued by the County is required for this project. Please submit for permit as the design is completed. 4. Please align FES-5 with the direction of flow. 5. Consideration should be given to rip rap aprons for each driveway culvert and at outfall to pond. 6. The ditch downstream of FES-4 appears to have excess slope. NHC Environmental Health, Dustin Fenske 910-798-6732 1. Site plan reflects connection to public water and sewer. No records could be found for existing water wells or septic systems for this address. 2. Proposed infrastructure does not violate setbacks to any surrounding properties well or septic systems. 3. Be mindful of large irrigation wells for farmland on this property. Irrigation wells could be present and if encountered should be properly abandoned by a Certified Well Driller. NHC Addressing, Katherine May 910-798-7443 1. The building will be addressed off Triumph Drive. Please contact me following TRC approval for address assignment. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 1. CFPUA TRC Comments provided are preliminary comments only. 2. Utility Plan review required by CFPUA is moving toward becoming paperless. When ready to submit plan review package, upload all documents to https://www.cfpua.org/FormCenter/Engineering-3/Engineering-Plan-Review-103. 3. CFPUA water and sewer are not available; CFPUA water and sewer could be made available through mainline extensions. NCDOT, Nick Drees 910-398-9100 See attached. 4011 Blue Clay Road – Francini at Blue Clay Rd – Commercial Site Plan – TRC Review Page | 4 WMPO, Jamar Johnson 910-473-5130 See attached. Brad Shaver USACOE Brad.E.Shaver@usace.army.mil 1. Blue Clay is proposed on a site with an active (JD), however, the proposed location does not have any anticipated impacts. Comments not received at this time from: Emergency Services & E911, Steve Still NCDEQ, Chad Coburn New Hanover Soil & Water, Dru Harrison USACE, Rachel Capito NCDEMLR, Dan Sams DCM, Tanya Pietila STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION ROY COOPER J.R. “JOEY” HOPKINS GOVERNOR SECRETARY Mailing Address: NC DEPARTMENT OF TRANSPORTATION DISTRICT 3 ENGINEER’S OFFICE 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 04-11-03 COURIER Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Memorandum To: New Hanover County Technical Review Committee Date: February 28, 2024 Subject: Blue Clay Business Flex Park (4011 Blue Clay Rd.) ________________________________________________________________________ These are preliminary comments and are based on the plans as submitted for the proposed site. They are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. General Comments: NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT Online Portal.https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx Since the proposed development is within the Blue Clay Industrial Park this site does not need a driveway permit or an encroachment agreement since there is no work taking place inside the NCDOT Right of Way. The Blue Clay Industrial Park should submit a driveway permit for the required improvements per the approved TIA. The Blue Clay Industrial Park currently does not have preliminary plan approval. x Revised plans should be submitted to NCDOT for review. Traffic Impact Analysis: x Roadway improvements are required per the approved TIA for the industrial park. x Per the approved TIA provide an internal protected stem of 125 feet measured from the right-of-way. Site Plan Comments: Sight Triangles and Sight Distance: x Show and label the 10’ X 70’ NCDOT sight triangles. o No obstructions shall be placed within the NCDOT sight triangles. Mailing Address: NC DEPARTMENT OF TRANSPORTATION DISTRICT 3 ENGINEER’S OFFICE 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 04-11-03 COURIER Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 x Show and label the appropriate sight distances. o No obstructions shall be placed within the stopping sight distance. No gates are allowed within 100’ from the right-of-way. This road is public but has not been accepted by NCDOT. For it to be eligible to be taken over in the future, any work within the right of way will need to be completed per NCDOT standards. Should you have any questions please reach out to the NCDOT District Office (910-398-9100). OHP OHP OHP OHP 15 ' ' S A N 15' ' S A N 15' ' S A N 15'' S A N 15 ' ' S A N 15 ' ' S A N 15' ' S A N 15' ' S A N 15 ' ' S A N 15 ' ' S A N OH P OHP OH P OH P OH P OH P OHP X X X X UGT UG T UGT UG T UG T UG T UG T UG T UG T UG T UGT U UG T UGT UG T UG T UG T UG T UG T UG T UG T UG T UG T UGT UGT UG T UGT UG T UG T UG T UG T UG T UG T UG T UG T UG T UG T LEGEND AND NOTES1OVERALL SITE PLAN2 0 SCALE: 1"=30' (Horiz.) 60'30'30' DESCRIPTIONS DATEREV.NO. REVISIONS SCALE HORIZONTAL: VERTICAL: SEAL STATUS: DRAWN PROJ. MGR. DESIGNED CHECKED DATE: MCE PROJ. # SEAL www.mckimcreed.com License: F-1222 TRC SUBMITTAL DRAWING NUMBER REVISION NEW HANOVER COUNTY, NORTH CAROLINA 09724-0001 BPD/BMJ/HKA BPD/RAM RAM RAM 243 North Front Street Phone: (910)343-1048, Fax: (910)251-8282Wilmington, North Carolina 28401 FRANCINI AT BLUE CLAY ROAD 2/1/2024 FRANCINI INC. 406 LANDMARK DRIVE WILMINGTON, NC 28412 (910) 398-2097 30'-0" 125'-5" 10' X 70' NCDOT Sight Triangles PERMANENTOUTLET PROTECTION PERMANENT OUTLETPROTECTION OVERALL GRADING PLAN2 LEGEND AND NOTES1 0 SCALE: 1"=30' (Horiz.) 60'30'30' DESCRIPTIONS DATEREV.NO.REVISIONS SCALE HORIZONTAL: VERTICAL: SEAL STATUS: DRAWN PROJ. MGR. DESIGNED CHECKED DATE: MCE PROJ. # SEAL www.mckimcreed.com License: F-1222 TRC SUBMITTAL DRAWING NUMBER REVISION NEW HANOVER COUNTY, NORTH CAROLINA 09724-0001 BPD/BMJ/HKA BPD/RAM RAM RAM 243 North Front Street Phone: (910)343-1048, Fax: (910)251-8282Wilmington, North Carolina 28401 FRANCINI AT BLUE CLAY ROAD 2/1/2024 FRANCINI INC. 406 LANDMARK DRIVE WILMINGTON, NC 28412 (910) 398-2097 GRADING AND DRAINAGE PLAN C7.0 1"=30' N/A 0 INSET A INSET A GENERAL NOTES: 1. INITIATE EROSION CONTROL SEQUENCE BEFORE BEGINNING CLEARINGAND GRADING OPERATIONS.2. CLEAR AREA WITHIN THE LOD AND ESSENTIAL SITE IMPROVEMENTS OFALL VEGETATION. PROTECT VEGETATION BEYOND GRADING LIMITS.3. STRIP TOPSOIL TO FULL DEPTH DESCRIBED IN THE EROSION CONTROLPLANS IN AREAS TO BE GRADED AND STOCKPILE.4. COMPACT ALL STRUCTURAL FILL AREAS AND SLOPES TO 95% OFMAXIMUM DENSITY. AREAS LESS THAN 3.0 FEET OF FILL INNON-STRUCTURAL AREAS MAY BE COMPACTED TO 90% OF MAXIMUMDENSITY.5. ALL BANK AND SWALE SIDE SLOPES SHALL BE GRADED WITH NOGREATER THAN 3:1 SLOPES.6. ALL DISTURBED AREAS SHALL BE SMOOTHLY GRADED TO PROMOTEPOSITIVE DRAINAGE AND STABILIZED WITH TOPSOIL, SEED, AND MULCH.IF SETTLEMENT OCCURS, TOPSOIL, SEEDING, AND MULCH SHALL BEREPEATED UNTIL SETTLEMENT SUBSIDES. (SEE EROSION ANDSEDIMENT CONTROL DETAILS AND SPECIFICATIONS.)7. ALL AREAS ARE TO BE GRADED SO THAT NO AREAS OF STANDINGWATER OCCUR.8. OPERATOR SHALL FIELD VERIFY EXISTING TOPOGRAPHY IN RELATIONTO THE PROPOSED GRADES TO ENSURE DRAINAGE IN THE DIRECTIONSINDICATED ON THE PLAN.9. ALL SELECT AND BORROW MATERIAL SHALL MEET CRITERIA SET FORTHBY SECTIONS 1016 AND 1018 OF THE NORTH CAROLINA DEPARTMENT OFTRANSPORTATION'S STANDARDS AND SPECIFICATIONS FOR ROADSAND STRUCTURES.10. THE ENGINEER AND THE CONTRACTOR SHALL INSPECT ALL EXISTINGPIPES USED IN THE FINAL DRAINAGE SYSTEM AND AGREE ON THECONDITION OF THE PIPES PRIOR TO CONSTRUCTION. IF DAMAGEOCCURS TO THESE PIPES DURING CONSTRUCTION, THE CONTRACTORSHALL BE RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF THEPIPE(S).11. EXISTING PAVING, CONCRETE, AND OTHER UNSUITABLE MATERIALSINCLUDING UNDERCUT EXCAVATION SHALL NOT BE USED AS FILLMATERIAL AND SHALL BE DISPOSED OF OUTSIDE THE PROJECT LIMITSAT THE CONTRACTOR'S EXPENSE. THE CONTRACTOR IS RESPONSIBLEFOR ALL PERMITTING AND FEES FOR DISPOSAL.12. ALL PIPE BEDDING SHALL BE CLASS "C" UNLESS OTHERWISE DIRECTEDBY THE ENGINEER.13. ALL TREES, STUMPS, ROOT MAT, ETC. SHALL BE ENTIRELY REMOVEDREGARDLESS OF DEPTH. BURIAL OF ORGANIC MATERIAL WITHIN THEPROJECT LIMITS IS NOT PERMITTED. OPEN BURNING OF DOWNEDTREES AND STUMPS MAY BE PERMITTED AT A LOCATION APPROVED BYOWNER AND WITHIN REGULATIONS OF LOCAL MUNICIPALITY. CHIPPEDMATERIALS MUST BE REMOVED PRIOR TO THE PLACEMENT OFEMBANKMENT OR TOPSOIL.14. ALL STORM DRAINAGE PIPES SHALL BE RCP CLASS III UNLESSOTHERWISE NOTED ON THE PLANS. HP PIPE MAY BE USED IN LIEU OFCONCRETE PIPE OR ENGINEER APPROVED EQUAL. ALL STORMWATEROUTFALL PIPES MUST BE RING GASKET RCP.15. THE CONTRACTOR IS SOLELY RESPONSIBLE TO OBTAIN OFF-SITE SPOILAREAS FOR DISPOSAL OF EXCESS AND/OR UNSUITABLE MATERIALS ASNECESSARY. OFF-SITE SPOIL AREAS MUST BE SUBMITTED TO THEENGINEER AND APPLICABLE REGULATORY AGENCIES PRIOR TOUTILIZATION BY THE CONTRACTOR. NO AREAS DESIGNATED ASWETLANDS WILL BE PERMITTED FOR USE AS A DISPOSAL SITE. THECONTRACTOR SHALL SUBMIT DOCUMENTATION TO THE ENGINEER THATNO WETLANDS WILL BE IMPACTED. THE ENGINEER WILL NOT CONSIDERANY DELAYS OR MONETARY CLAIMS OF ANY NATURE RESULTING FROMTHE CONTRACTOR'S FAILURE OR DIFFICULTY IN FINDING NECESSARYDISPOSAL SITES TO MEET THE TIME FRAMES AND CAPACITIESREQUIRED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PLANS,PERMITS, EROSION AND SEDIMENT CONTROL MEASURES, ETC.REQUIRED BY THE APPROPRIATE REGULATORY AGENCIES FORUTILIZING OFF-SITE SPOIL AREAS. THE CONTRACTOR SHALL CERTIFY TOTHE ENGINEER THAT ALL REQUIRED PERMITS HAVE BEEN OBTAINEDPRIOR TO UTILIZING THE OFF-SITE SPOIL AREAS. ALL COSTS FORPROCURING AND UTILIZING THE OFF-SITE SPOIL AREAS ARE TO BEINCIDENTAL TO THE BASE BID.16. APPROVED COVERS TO PREVENT MATERIAL FROM LEAVING THETRUCKS MUST BE INSTALLED OVER ALL LOADED TRUCKS HAULINGBORROW, EXCAVATED MATERIAL AND/OR FINE AGGREGATES TO ORFROM THE PROJECT SITES OVER STATE MAINTAINED ROADS. ANYMATERIALS DELIVERED, TRANSPORTED, OR REMOVED IN UNCOVEREDTRUCKS WILL BE INCORPORATED INTO THE PROJECT OR REMOVEDFROM THE SITE WITH NO ADDITIONAL PAYMENT TO THE CONTRACTORFOR FURNISHING, REMOVING, OR PLACING THE MATERIALS INVOLVED.17. DEWATERING: THE CONTRACTOR SHALL AT ALL TIMES PROVIDE ANDMAINTAIN AMPLE MEANS AND EQUIPMENT WITH WHICH TO REMOVE ANDPROPERLY DISPOSE OF ANY AND ALL WATER ENTERING THEEXCAVATION OR OTHER PARTS OF THE WORK AND KEEP ALLEXCAVATIONS DRY UNTIL SUCH TIME AS PIPE LAYING AND GRADING ISCOMPLETED. NO WATER SHALL BE ALLOWED TO RISE AROUND THE PIPEIN UNBACKFILLED TRENCHES NOR SHALL IT BE ALLOWED TO RISE OVERMASONRY UNTIL THE CONCRETE OR MORTAR HAS SET (MINIMUM 24HOURS). ALL WATER PUMPED OR DRAINED FROM THE WORK SHALL BEDISPOSED OF IN SUCH A MANNER AS TO PREVENT SILTATION ANDEROSION TO ADJACENT PROPERTY OR OTHER CONSTRUCTION.18. DO NOT PLANT TREES WITHIN UTILITY AND DRAINAGE EASEMENTS.19. CONTRACTOR TO CAREFULLY ROOT PRUNE TREES, CREATING CLEANCUTS. NO ROUGH BREAKS OF ROOTS (TYPICALLY AS THE RESULT OFMECHANICAL EQUIPMENT) WILL BE IS ACCEPTABLE. WATER LINE FIRE HYDRANT WATER VALVE WATER METER WATER TEE SANITARY SEWER SANITARY FORCE MAIN PUBLIC UTILITY EASEMENT TRIUMPH DRIVE(60' PUBLIC R/W) LO G I S T I C S R O A D (60 ' P U B L I C R / W ) A 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 6fm 16W 16W 16W 16W 16W 16W 16W 16 W 16W 16W 16 W 16W 16W 16W 16W 16 W 16 W 6fm 6fm6fm 8W 8W 6fm UTE UTE UTE UTE UTE UTE UTE UTE UTE UT E UTE UTE UTE UTE UTE U UTE UTEUTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTEUTE UTEUTEUTEUTEUTEUTEUTEUTEUTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UT E UTE UTE UTE UTE UTE UTE UTE UTEUTE UTE EXISTING UTILITYEASEMENT FIRE PUMPROOM RPZ FIREHYDRANT EXISTING FIREHYDRANT 2" DOMESTICWATER SERVICE 6" FIRE LINE 6" CLEAN-OUT 6" FIRESERVICE LINE 6" CLEAN-OUT 6" SANITARYSEWER SERVICE LEGEND AND NOTES1OVERALL UTILITY PLAN2 0 SCALE: 1"=60' (Horiz.) 120'60'60' DESCRIPTIONS DATEREV.NO. REVISIONS SCALE HORIZONTAL: VERTICAL: SEAL STATUS: DRAWN PROJ. MGR. DESIGNED CHECKED DATE: MCE PROJ. # SEAL www.mckimcreed.com License: F-1222 TRC SUBMITTAL DRAWING NUMBER REVISION NEW HANOVER COUNTY, NORTH CAROLINA 09724-0001 BPD/BMJ/HKA BPD/RAM RAM RAM 243 North Front Street Phone: (910)343-1048, Fax: (910)251-8282Wilmington, North Carolina 28401 FRANCINI AT BLUE CLAY ROAD 2/1/2024 FRANCINI INC. 406 LANDMARK DRIVE WILMINGTON, NC 28412 (910) 398-2097 17 5 . 0 0 ' 12 5 . 0 0 ' 75 . 0 0 ' 20 4 . 0 0 ' 0 SCALE: 1"=30' (Horiz.) 60'30'30' DESCRIPTIONS DATEREV.NO. REVISIONS SCALE HORIZONTAL: VERTICAL: SEAL STATUS: DRAWN PROJ. MGR. DESIGNED CHECKED DATE: MCE PROJ. # SEAL www.mckimcreed.com License: F-1222 TRC SUBMITTAL DRAWING NUMBER REVISION NEW HANOVER COUNTY, NORTH CAROLINA 09724-0001 BPD/BMJ/HKA BPD/RAM RAM RAM 243 North Front Street Phone: (910)343-1048, Fax: (910)251-8282Wilmington, North Carolina 28401 FRANCINI AT BLUE CLAY ROAD 2/1/2024 FRANCINI INC. 406 LANDMARK DRIVE WILMINGTON, NC 28412 (910) 398-2097 LEGEND AND NOTES1LANDSCAPE PLAN2 LANDSCAPE DATA SYMBOL COMMON / BOTANICAL NAME CANOPY TREE AUTUMN BLAZE RED MAPLE / ACER RUBRUM `AUTUMN BLAZE` HIGH RISE LIVE OAK / QUERCUS VIRGINIANA `HIGH RISE` NATIVE FLAME HORNBEAM / CARPINUS CAROLINIANA `NATIVE FLAME` SAWLEAF ZELKOVA / ZELKOVA SERRATA `VILLAGE GREEN` TAYLOR EASTERN REDCEDAR / JUNIPERUS VIRGINIANA `TAYLOR` UNDERSTORY TREES CRAPE MYRTLE / LAGERSTROEMIA X `NATCHEZ` SHRUBS CHINDO VIBURNUM / VIBURNUM AWABUKI `CHINDO` DWARF BURFORD HOLLY / ILEX CORNUTA `DWARF BURFORD` DWARF YAUPON / ILEX VOMITORIA `NANA` EULALIA GRASS / MISCANTHUS SINENSIS `MORNING LIGHT` PINK DRIFT® GROUNDCOVER ROSE / ROSA X 'MEIJOCOS' PINK MUHLY GRASS / MUHLENBERGIA CAPILLARIS YAUPON HOLLY / ILEX VOMITORIA GROUND COVERS BERMUDA GRASS / CYNODON DACTYLON PLANT SCHEDULE MEMORANDUM To: New Hanover County Technical Review Committee Date: 2/23/24 Subject: Blue Clay Business Flex Park Comments: • Provide highest and best land use(s) to occupy the flex space for trip generation purposes. • Show ADA detectable warning pads at access aisles. • It is recommended to have access aisles on the passenger side of ADA parking stalls since that side is where the wheelchair lift is based on the 2010 ADA Standards for Accessible Design. • Label dimension of drive aisle between parking rows. • Label dimension of the access aisles and ADA parking stalls. • Provide turning templates of the largest design vehicle to access the site. NCDOT Projects: TIP Projects in the Area: N/A WMPO 2045 Projects: RW-26 Blue Clay Road Widening Location: US 117 to N Kerr Ave Construction Year: 2030 New Hanover County CTP: N/A TIA: Based on the 11th edition ITE Trip Generation Manual, a TIA is Land Use (ITE Code) Intensity Unit 24 Hour Volumes AM Peak Hour Trips PM Peak Hour Trips