02-EX 1.0-Turn TemplatePID: R01708-003-002-000
SCHROEDER ALLAN F BARBARA
BK 5638 PG 2007
ZONE: B-1 PID: R01708-003-003-000
ELDERDICE MILDRED FAMILY TRUST
BK 9911 PG 2619
ZONE:B-1
PID: R01700-003-003-000
ST STANISLAUS CATHOLIC CHURCH
BK 2088 PG 992
ZONE: RA
PID: R01708-002-002-000
CMH HOMES INC
BK 6529, PG 0384
ZONE: RA
PID: R01708-002-003-000
RICHARDSON SCOTT CASSANDRA
BK 4893, PG 2195
ZONE: RA PO
S
S
I
B
L
E
N
E
W
R
/
W
R/W
B
Y
D
E
E
D
UF
O
UF
O
UF
O
UF
O
UF
O
UF
O
UF
O
UF
O
UFO
UF
O
UF
O
UF
O
UF
O
UF
O
UF
O
UF
O
UFO
UF
O
UFO
UF
O
UF
O
UF
O
PARMELE ROAD
(60' PUBLIC R/W)
CA
S
T
L
E
H
A
Y
N
E
R
O
A
D
(
U
S
H
W
Y
1
1
7
)
(6
0
'
P
U
B
L
I
C
R
/
W
)
ZONE: R-20 ZONE: R-20
ZONE: RA
PROPOSED BUILDING
11,357 SF
EX 1.0
TU
R
N
T
E
M
P
L
A
T
E
N
A
D
8
3
0
SCALE 1"=20'
40'20'
Project No.
56400
Date:
Sheet No.
CA
S
T
L
E
H
A
Y
N
E
F
I
R
E
S
T
A
T
I
O
N
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
F
I
R
E
D
E
P
A
R
T
M
E
N
T
Drawn by:
Checked by:
Revisions:
ALL NOTES APPLY TO ALL DRAWINGS AND ALL TRADES. IT IS THE RESPONSIBILITY OF ALL CONTRACTORS AND
TRADES TO COORDINATE THE INSTALLATION OF THEIR WORK WITH THE INSTALLATION OF WORK BY ALL OTHER
CONTRACTORS AND TRADES. THE REQUIREMENTS OF THE DRAWINGS, GENERAL REQUIREMENTS AND ALL ITEMS
OF THE CONTRACT DOCUMENTS ARE EQUALLY BINDING ON ALL CONTRACTORS AND TRADES. EACH
CONTRACTOR IS REQUIRED TO MAINTAIN FULL SETS OF THE CONTRACT DOCUMENTS FOR HIS EMPLOYEES USE
ON THE PROJECT TO ASSURE THAT ALL WORK IS PROPERLY COORDINATED AND INSTALLED WITH THE WORK OF
OTHER CONTRACTORS AND TRADES.
WHENEVER THERE ARE DISCREPANCIES BETWEEN DRAWINGS, OR BETWEEN THE DRAWINGS AND
SPECIFICATIONS, OR CONFLICTS WITHIN THE SPECIFICATIONS AND/OR DRAWINGS, AND SUCH DISCREPANCY IS
NOT CALLED TO THE ARCHITECT'S ATTENTION IN TIME TO PERMIT CLARIFICATION BY ADDENDUM, THE
CONTRACTOR SHALL BASE HIS BID UPON PROVIDING THE BETTER QUALITY OR GREATER OF WORK OR MATERIAL
CALLED FOR, SHALL SUBMIT A WRITTEN STATEMENT WITH HIS PROPOSAL NOTING SUCH DISCREPANCIES, AND
SHALL SO FURNISH AND INSTALL SUCH BETTER QUALITY OR GREATER QUANTITY UNLESS OTHERWISE ORDERED
IN WRITING.
GENERAL NOTE
03/29/2024
J GLAS
W ALTMAN
Addendum 02
5/10/2024
ww
w
.
s
c
n
-
a
r
c
h
i
t
e
c
t
s
.
c
o
m
1.
8
0
0
.
6
7
1
.
0
6
2
1
71
9
E
a
s
t
S
e
c
o
n
d
A
v
e
n
u
e
Ga
s
t
o
n
i
a
,
N
C
2
8
0
5
4
Ph
o
n
e
:
7
0
4
.
8
6
5
.
6
3
1
1
Fa
x
:
7
0
4
.
8
6
5
.
0
0
4
6
5410 Trinity Road, Suite 102Raleigh, NC 27607TEL 919.866.4951FAX 919.859.5663www.timmons.com
YOUR VISION ACHIEVED THROUGH OURS.
VIRGINIA NORTH CAROLINA
Site Development Residential Infrastructure Technology
THIS DRAWING PREPARED AT THE
RALEIGH OFFICE
56400-333
North Carolina License No. C-1652
2ND ROUND TRC
6/12/2024
30°
6
0
°
90
°
120
°
150°
180°34
.
2
9
1
f
t
M
i
n
R
a
d
i
u
s
(O
u
t
e
r
W
h
e
e
l
)
19.592ftMin Radius(Inner Wheel)
38.
7
2
4
f
t
M
i
n
R
a
d
i
u
s
(Outer Body)
19.4
2
2
f
t
Max Kickout 1.965ft
Vehicle Tracking V23.00.2540(20220624) (c) Autodesk, Inc. www.Autodesk.com
39
7 20
Aerial Fire TruckOverall Length 39.000ftOverall Width 8.167ftOverall Body Height 7.500ftMin Body Ground Clearance 0.750ftTrack Width 8.167ftLock-to-lock time 5.00sMax Wheel Angle 45.00°
AERIAL FIRE TRUCK PROFILE (NTS)
AERIAL FIRE TRUCK TURN TEMPLATE (NTS)