Loading...
HomeMy WebLinkAboutNorthchase Library TRC Approval Package Page | 1 COMMERCIAL SITE PLAN APPROVAL To: Curtis Day, Davenport Engineering From: Amy Doss, Development Planner Date: August 8, 2024 Subject: Commercial Site Plan Approval – Northchase Library – 4400 Northchase Parkway NE The commercial site plan for a public library located at 4400 Northchase Parkway NE has been approved. The approved commercial site plan consists of the construction of a 19,941 square foot building. This approval is valid for two (2) years unless a building permit or zoning compliance approval authorizing the approved development is obtained. Please note the project may be subject to additional regulations of the County’s development ordinances, including but not limited to, those referenced in the initial Technical Review Committee (TRC) dated December 6, 2023 and / or subsequent revised comments. In addition, this approval does not relieve the applicant from any law, regulation, or requirement of any other government or regulatory agency. If you have any questions, I may be reached at adoss@nhcgov.com or at (910) 798-7571. Thank you, Amy Doss Development Review Planner HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADINGAND STORMWATER MANAGMENT EASEMENT) 100 101 102 HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADINGAND STORMWATER MANAGMENT EASEMENT) T S S S S GVGV WV WV WV WV WVWV CB LEGEND EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T T T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF SD >SD > EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE X X X W FHFH WV SS S CO 19 20 OE T E LP T T-001 TITLE SHEET NORTHCHASE BRANCH LIBRARY WILMINGTON, NEW HANOVER COUNTY, NORTH CAROLINA INDEX OF DRAWINGS TITLE SHEET EXISTING CONDITIONS PLAN SITE PLAN GRADING PLAN GRADING PLAN BLOWUPS DRAINAGE AREA MAP STORM PROFILES PAVING PLAN SIGNAGE & STRIPING PLAN UTILITY PLAN UTILITY PROFILES SITE DETAILS SITE DETAILS STORM DRAIN DETAILS UTILITY DETAILS UTILITY DETAILS STORMWATER MANAGEMENT PLAN STORMWATER MANAGEMENT PLAN STORMWATER MANAGEMENT DETAILS STORMWATER MANAGEMENT - EXISTING PEAK FLOW STORMWATER MANAGEMENT - PROPOSED PEAK FLOW EROSION & SEDIMENT CONTROL - EXISTING CONDITIONS & DEMO PLAN EROSION & SEDIMENT CONTROL - INTERIM CONDITIONS PLAN EROSION & SEDIMENT CONTROL - FINAL CONDITIONS PLAN EROSION & SEDIMENT CONTROL DETAILS EROSION & SEDIMENT CONTROL DETAILS EROSION & SEDIMENT CONTROL DETAILS EROSION & SEDIMENT CONTROL NOTES EROSION & SEDIMENT CONTROL NOTES T-001 C-100 C-200 C-201 C-201A C-202 C-203 C-300 C-301 C-400 C-401 C-500 C-501 C-502 C-503 C-504 C-600 C-601 C-602 C-603 C-604 EC-100 EC-101 EC-102 EC-103 EC-104 EC-105 EC-106 EC-107 NO. SHEET DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 LOCATION MAP SCALE: 1" = 60' 1.CITY OF WILMINGTON STANDARDS, SPECIFICATIONS, AND STANDARD DETAILS DATED 2001 AND AS AMENDED ALONG WITH NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES DATED JANUARY 2024 AND AS AMENDED APPLY TO THESE PLANS. 2.ALL NECESSARY INSPECTIONS AND/OR CERTIFICATIONS REQUIRED BY CODES AND/OR UTILITY SERVICE COMPANIES SHALL BE PERFORMED PRIOR TO THE FINAL CONNECTIONS OF SERVICES. 3.ATTENTION IS DRAWN TO THE FACT THAT THE SCALE OF THESE DRAWINGS MAY HAVE BEEN DISTORTED DURING THE REPRODUCTION PROCESS. 4.THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADAPTATION BY JOHN DAVENPORT ENGINEERING, INC. SHALL BE WITHOUT LIABILITY TO JOHN DAVENPORT ENGINEERING, INC. NOTES 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 60ft. 30 6060 120 THE CONTRACTOR SHALL NOTIFY NORTH CAROLINA 811 AT LEAST FIVE (5) WORKING DAYS PRIOR TO STARTING ANY WORK. ALL CONTRACTORS AND SUBCONTRACTORS INVOLVED WITH THE STORM WATER POLLUTION PREVENTION SHALL OBTAIN A COPY OF THE EROSION CONTROLPLAN (ECP) AND THE STATE OF NORTH CAROLINA DEPARTMENT OF THE ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERALPERMIT TO DISCHARGE STORMWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES PERMIT) AND BECOME FAMILIAR WITHTHEIR CONTENTS . TOPOGRAPHIC INFORMATION SHOWN HEREON IS BASED ON A FIELD SURVEY DATED MARCH 24, 2023, COMPLETED BY CAPE FEAR ENGINEERING. OBSTRUCTIONS SHOWN ON THESE DRAWINGS ARE FOR THE CONVENIENCE OF THE CONTRACTOR ONLY. DAVENPORT DOES NOT WARRANT OR GUARANTEETHE CORRECTNESS OR THE COMPLETENESS OF THE INFORMATION GIVEN. THE CONTRACTOR MUST VERIFY ALL SUCH INFORMATION TO HIS OWNSATISFACTION. IN THE EVENT THAT INFORMATION IS IN CONFLICT WITH INFORMATION OUTLINED, THE CONTRACTOR SHALL IMMEDIATELY BRING IT TO THEATTENTION OF THE ENGINEER PRIOR TO STARTING ANY WORK. CONTRACTOR TO VERIFY LOCATION AND ELEVATION OF EXISTING UTILITIES SHOWN HEREON BEFORE STARTING ANY WORK ON THESE PLANS. CONTRACTORAGREES TO BE FULLY RESPONSIBLE FOR THE COST OF ANY AND ALL DAMAGES WHICH OCCUR AS A RESULT OF A FAILURE TO EXACTLY LOCATE ANDPRESERVE ANY AND ALL EXISTING UTILITIES TO REMAIN. CONTRACTOR SHALL REMOVE DRIVEWAY ENTRANCES AND STRUCTURES TO LIMITS INDICATED ON THE DRAWING. CONTRACTOR SHALL NOT PROCEED WITH ANY DEMOLITION WORK UNTIL ALL UTILITY DISCONNECTIONS ARE COMPLETED AND VERIFIED IN WRITING. BURNING OF COMBUSTIBLE MATERIALS FROM DEMOLISHED STRUCTURES WILL NOT BE PERMITTED ON SITE. CONTRACTOR SHALL ENSURE THAT ALL MATERIAL REMOVED FROM DEMOLISHED STRUCTURES ARE LEGALLY DISPOSED OF OFF-SITE. SEE EXISTING CONDITIONS AND DEMOLITION PLAN FOR APPROXIMATE LIMITS OF PAVING REMOVAL. IT SHALL BE DISTINCTLY UNDERSTOOD THAT FAILURE TO MENTION SPECIFICALLY ANY WORK WHICH WOULD NORMALLY BE REQUIRED TO COMPLETE THISPROJECT SHALL NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITY TO COMPLETE SUCH WORK. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ENGINEER OF ANY DEVIATION FROM THIS PLAN PRIOR TO ANY CHANGE BEING MADE.ANY DEVIATION FROM THIS PLAN WITHOUT WRITTEN AUTHORIZATION FROM THE ENGINEER WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. TRAFFIC CONTROL DEVICES, MARKINGS AND SIGNING SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE MANUAL OF UNIFORM TRAFFIC CONTROLDEVICES (MUTCD). ALL PLAN DIMENSIONS ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED. SAW CUT EXISTING PAVEMENT AS NEEDED TO INSTALL NEW CONSTRUCTION. THE CONTRACTOR SHALL NOTE THAT IN CASE OF A DISCREPANCY BETWEEN THE SCALED AND THE FIGURED DIMENSIONS SHOWN ON THESE PLANS, THEFIGURED DIMENSIONS SHALL GOVERN. TRENCH BACKFILL IN GRASS AREAS SHALL BE COMPACTED TO A MINIMUM 90% OF MAXIMUM DRY DENSITY IN ACCORDANCE WITH A.A.S.H.T.O. VERIFYDESIGNATION T-180, METHOD C. TRENCH BACKFILL IN STRUCTURAL AND PAVEMENT AREAS SHALL BE PLACED IN EIGHT INCH LOOSE LIFTS AND COMPACTEDTO AT LEAST 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY (ASTM D-1557). IN PAVED AREAS, FILL BELOW THE TOP 12 INCHES SHOULD BECOMPACTED TO 97%. CONTRACTOR SHALL ADJUST ALL EXISTING UTILITIES, I.E. MANHOLE FRAMES AND COVERS, ETC. WITHIN THE LIMITS OF THE CONTRACT TO PROPOSEDGRADES AS REQUIRED. THE CONTRACTOR SHALL MAINTAIN POSITIVE DRAINAGE AWAY FROM STRUCTURES AT ALL TIMES. CONTRACTOR SHALL INSTALL SEDIMENT CONTROLS PRIOR TO BEGINNING ANY WORK AND MAINTAIN SEDIMENT CONTROLS THROUGHOUT THE ENTIREDURATION OF DEMOLITION AND CONSTRUCTION ACTIVITIES. ALL EXCAVATION SHALL BE BACKFILLED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. IN THE EVENT THAT A PORTION OF A UTILITY IS TO BEREMOVED THE CONTRACTOR SHALL TERMINATE AND CAP TO THE LIMITS INDICATED IN ACCORDANCE WITH ALL STATE AND LOCAL REQUIREMENTS. SHOULD THE CONTRACTOR DISCOVER DISCREPANCIES BETWEEN THE PLANS AND FIELD CONDITIONS, THE ENGINEER IS TO BE NOTIFIED IMMEDIATELY TORESOLVE THE SITUATION. SHOULD THE CONTRACTOR MAKE FIELD CORRECTIONS OR ADJUSTMENTS WITHOUT NOTIFYING THE ENGINEER, THEN THECONTRACTOR ASSUMES ALL RESPONSIBILITY FOR THOSE CHANGES. ANY STRUCTURE TO BE REMOVED SHALL REQUIRE A SEPARATE DEMOLITION PERMIT FROM THE BUILDING INSPECTIONS DEPARTMENT. MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED THROUGHOUT EXIT DISCHARGES IN ACCORDANCE WITH NCBC. ALL EXISTING AND PROPOSED OVERHEAD POWER LINES ARE INDICATED ON THE SITE PLAN. IF NO OVERHEAD POWER LINES INDICATED,THERE SHALL BE NONEWITHIN 10 FEET OF THE PROPERTY LIMITS. GENERAL NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. OWNER:ENGINEER:SURVEYOR: NEW HANOVER COUNTY 230 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 (910) 798-7311 CAPE FEAR ENGINEERING 151 POOLE RD., SUITE 100 LELAND, NC 28541 P: (910) 383-1044 CONTACT: JASON W. FISHER, RLS JOHN DAVENPORT ENGINEERING 119 BROOKSTOWN AVENUE, PH 1 WINSTON-SALEM, NC 27101 P: (336) 744-1636 CONTACT: CURTIS DAY, PE, LEED AP OWNER REPRESENTATIVE: NEW HANOVER COUNTY - FACILITIES MANAGMENT 200 DIVISION DRIVE WILMINGTON, NC 28401 (910) 798-4338 CONTACT: KEVIN CAISON OWNER/APPLICANT: NEW HANOVER COUNTY FACILITIES MANAGEMENT 200 DIVISION DRIVE. WILMINGTON, NC 28401 P: 910-798-4337 CONTACT: KEVIN CAISON ENGINEER: CURTIS DAY, P.E. DAVENPORT ENGINEERING 119 BROOKSTOWN AVENUE WINSTON-SALEM, NC 27101 (202) 240-9068 PARCEL PIN ID. : R02611-002-001-000 PROPERTY REFERENCE: D.B. 2081, D.P. 0285 ZONING: PD WATERSHED: PRINCE GEORGE CREEK ACREAGE: 2.95 ACRES LIMIT OF DISTURBANCE: 3.15 ACRES IMPERVIOUS SURFACE: 0.00 ACRES CURRENT WITHIN LOD 1.90 ACRES PROPOSED WITHIN LOD PROPOSED USE: 19,941 S.F. LIBRARY PARKING CALCULATIONS: REQUIRED VEHICLE SPACES: 50 SPACES (2.5 SPACES PER 1000 SF)PROVIDED VEHICLE SPACES: 99 SPACESREQUIRED ADA SPACES: 4 SPACES (INCLUDING 1 VAN)PROVIDED ADA SPACES: 5 SPACES (INCLUDING 1 VAN) SITE DATA 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 16.5° SCALE 1" = 2000' T S S S S GVGV WV WVWV WV WVWV X XX HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) 100 101 102 HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) LEGEND EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE X FHFH WV S CO 19 20 T E LP T C-100 EXISTING CONDITIONS & DEMOLITION PLAN NOTE: AN ADVANCE SITE PREP AND DEMOLITION PLAN WAS PREVIOUSLY SUBMITTED FOR THIS PROJECT, FOR THE CLEARING, MASS GRADING, PLACEMENT AND REMOVAL OF SURCHARGE AND ASSOCIATED EROSION AND SEDIMENT CONTROLS. THE EXISTING CONDITIONS SHOWN HEREON REFLECT THE CONDITIONS OF THE SITE AT THE COMPLETION OF THAT WORK. c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30ft. 15 3030 60 GRAPHIC SCALE ( IN FEET ) 16.5° SCALE 1" = 2000' PROPOSED GRADING & STORMWATER MANAGMENT EASEMENT T GVGV HOSKINS TOM MB 5160 PG 1614PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) HOSKINS TOM MB 5160 PG 1614PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) X X 11 5 FI R E L A N E FIRE L A N E FI R E L A N E FIRE LANE FIRE LANE 20 ' FI R E L A N E FIRE L A N E DUMPSTERPAD HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y AS P H A L T P A V I N G HEA V Y D U T Y A S P H A L T PAV I N G POROUS CONCRETE POR O U S CON C R E T E FI R E L A N E FIRE L A N E VAN X X X X X X X X X X X X X X X X HE A V Y D U T Y AS P H A L T P A V I N G CA N O P Y 8 FOOT BRIDGE (BY OTHERS) PAVILLION(ADD-ALT.) BOOKDROP D O N O T E N T E R PO R O U S C O N C R E T E PO R O U S C O N C R E T E HOSE PULL 395' 20' 10'x70' SIGHT TRIANGLE 10'x70' SIGHT TRIANGLE SWMWETLAND KB 1 STORY LIBRARY BUILDING FFE=35.50 SSD = 305FT SSD = 305FT STOPPING SIGHT DISTANCE (SSD) TRIANGLE STOPPING SIGHT DISTANCE (SSD) TRIANGLE COCO CO CO CO 17202018 SSD = 305FT FU T U R E M U L T I - U S E P A T H W A Y ( B Y O T H E R S ) SW M A C C E S S ( U N P A V E D ) SWM WETLAND FOREBAY FOREBAY FOREBAY DEEPPOOL DEEPPOOL DEEPPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL 6 C-501 8 C-501 CONCRETE WHEEL STOP (TYP. OF 8) PLANTER BOXES & BOULDERS SEE LANDSCAPING PLANS CONCRETE BOLLARDS (TYP.) 8 EA. @4' O/C 5 C-501 ADA PARKING SIGNS (TYP.) OF 5 @4' O/C 8 C-500 VEHICULAR BRICK PAVERS 7 C-501 GRASS-PAVE FIRE LANE 1 A-400 DUMPSTER ENCLOSURE DIRECTIONAL SIGNS STOP SIGN STOPSIGN STOP SIGN STOP SIGN MONUMENT SIGN STOP SIGN DIRECTIONAL SIGN EDGE OF PLANTING BED EDGE OF PLANTING BED EDGE OF PLANTING BED 9'(TYP.)18'(TYP.) 9'(TYP.)18'(TYP.) 9' (TYP.) 18'(TYP.) 9' (TYP . ) 18 ' (TYP . ) 9' (TYP . ) 18 ' (TYP . ) 8'8'5'8'5'9'8' R 3 5 ' R3 5 ' R1 0 'R5' R10 ' R 5 ' R 1 0 ' R5' R10 ' R 1 5 ' R5' R 5 ' R10 ' R5'R5 ' R5' R5' R1 6 ' R 4 0 ' R3 5 ' R5 'R10' R1 6 ' R5' R5' R35' R59'R5 ' R5' R5' R35 ' R 5 ' R5' R77.00' R 5 ' R5 9 ' R5 ' R5' R5 5 ' 5' 10.59' 13.00' 45.28'31.63'31.48' 62.96' 63.07' 1 3 2 . 3 4 ' 73.78' 32.47' 24'18'18'24'18'18'24' 24.00' 24.00' 24' 15' 9.5' 24' 8.75 ' 6 . 4 9 ' 28.00' 24.00' 27.00' 1.5' 5.00 ' CON C . WALK 7,10 C-500 CURB RAMP TYPE 4 - SINGLE W/ DETECTABLE DOMES (TYP.) 7, 9 C-500 CURB RAMP TYPE 1 - MODIFIED W/ DETECTABLE DOMES (TYP.) 7 C-500 DETECTABLEDOMES (TYP.) KNOX BOX EDGE OF PLANTING BED EDGE OF PLANTING BED EDGE OF PLANTING BED LEGEND PROPERTY LINE EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK PROP. CONC. SIDEWALK PROP. STORM DRAIN PROP. WATER METER PROP. MILL & PAVE PROP. DOM. WATER BACK FLOW PREVENTER PROP. PERMEABLE CONCRETE PROP. STORMWATER WETLAND RELOCATED PARKING PAY STATION PROPOSED STREET LIGHT RELOCATED POWER POLE PROP. FIRE PROP. STORM MANHOLE PROP. SANITARY LINE PROP. SANITARY MANHOLE 8" SAN. PROP. POWER LINE PPP PPPPPPPPPPPPP PPPPPPPPP PPPPPPPPP PPPPPPPPP PPPPPPPPP PPPPPPP PROP. SMALL SWALE <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< co WM BFP REDUCED PRESSURE DETECTOR ASSEMBLY RPDA 2" W 4" F PROP. CLEANOUT PROP. FIRE HYDRANT PROP. WATER VALVE BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O PROP. FIRE DEPT. ACCESS PARKING SPACE COUNT 12 TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE PROPOSED SIGN X PROP. HEAVY DUTY ASPHALT PROP. HEAVY DUTY REINFORCED CONCRETE PROP. LANDSCAPE PAVERS FHFH WV S CO 19 20 T E LP T D PROP. RIP-RAP "GRASS-PAVE" SYSTEM PROP. TEE FITTING PROP. BEND FITTING PROP. REDUCER PROP. FIRE DEPT. ACCESSREINFORCED CONC. PAVERS C-200 SITE LAYOUT c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30ft. 15 3030 60 GRAPHIC SCALE ( IN FEET ) 16.5° SCALE 1" = 2000' c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30ft. 15 3030 60 GRAPHIC SCALE ( IN FEET ) 16.5° SCALE 1" = 2000' PROPOSED GRADING & STORMWATER MANAGMENT EASEMENT T WV WVWV + TC 34.41BC 33.91 HP +TC 34.89BC 34.39 TC 34.20BC 33.70 32.84 +33.59 +34.15 + + 28.50 + +TC 35.01BC 34.51 +TC 35.08BC 34.58 + + TC 35.22BC 34.72 TC 35.14BC 34.64 +TC 35.38BC 34.88 + TC 35.26BC 34.76 + TC 34.99BC 34.49 + TC 35.14BC 34.64 +TC 35.03BC 34.53 +TC 34.67BC 34.17 +TC 34.75BC 34.25 +TC 34.61BC 34.11 + TC 34.58BC 34.08+ TC 34.24BC 33.74 +TC 34.13BC 33.63 +TC 34.03BC 33.53 +TC 34.08BC 33.58 +TC 34.03BC 33.53 + + TC 34.72BC 34.22 + TC 34.63BC 34.13 +33.58 + + + +TC 35.77BC 35.27 TC 35.79BC 35.29 TC 35.93BC 35.43 TC 35.80BC 35.30 TC 34.85BC 34.35 +TC 34.95BC 34.45 +TC 35.26BC 34.76 + TC 33.68BC 33.18 +TC 33.78BC 33.28 +TC 34.50BC 34.00 +TC 35.50 BC 35.00 D O N O T E N T E R WM GV 2" D I P W ( D O M ) 8" D I P W ( F I R E ) 6" D I P W ( F I R E ) 6" P V C S E W E R 6" PV C S E W E R FIRE LANE POROUSCONCRETE 15 " R C P C L 1 V CO GV 3 5 3 5 3 4 3 4 33 CB7 EW1 CB2 POROUSCONCRETE POROUSCONCRETE 3 4 50' SETBACK 28. 5 3 3 3 2 3 1 3 0 HE A V Y D U T Y AS P H A L T P A V I N G 28.50 CO CO C O C O C O C O CO CO CO CO C O CO C O CO FOREBAY ++33.36 +33.87+33.30 TC 33.90BC 33.40+TC 34.20BC 33.70 + TC 33.45 BC 32.95 TC 33.17BC 33.17 +33.50 +TC 34.65BC 34.15 HP +33.70 +TC 34.12BC 33.62 +TC 34.17BC 33.67 +35.50 + +33.34 +33.44 + TC 33.75BC 33.25 HP HP TC 34.06BC 33.56 +TC 33.74BC 33.24 + TC 34.91BC 34.41 TC 34.65BC 34.57+ +35.01 HP TC 34.52BC 34.02 + TC 33.76BC 33.26 +33.18 +33.39+ TC 33.90BC 33.40 + TC 34.05BC 33.55 + + 34.8535.15 33.60 HP + + + + + TC 34.14 BC 33.64 + + + + + + + + + TC 33.23BC 33.23 TC 33.60BC 33.10 + + +28.50 TW=32.42 +TC 34.76BC 34.26 +34.95 TC 35.47BC 34.97 +35.50+35.41 TC 35.26BC 34.76+ TC 34.75BC 34.25 TC 34.23BC 33.83 TC 35.03BC 34.53 +TC 34.80BC 34.30 +TC 34.28BC 34.20 + + + TC 33.71BC 33.63 TC 33.50BC 33.42 TC 33.81BC 33.31 +TC 33.99BC 33.91 TC 34.39BC 33.89 TC 34.47BC 33.97 TC 34.75BC 34.25 + TC 34.55BC 34.47 +34.89 +34.85 +34.75 +34.90+34.70 + 35.05 HP +34.30+ ++34.40 34.30 34.40 TC 34.55BC 34.05 NOSEDOWN34.60 +TC 33.79BC 33.29 HP+35.25 D O N O T E N T E R +TC 34.67BC 34.17 + TC 35.17BC 34.67+ +34.75 + NOSEDOWN34.50 +34.70 TC 34.83BC 34.33+34.87 +28.50 + +34.60 DEPRESSEDCURB DEPRESSED CURB + TC 35.36BC 34.86 35.41 8" PVC SD 8" DIP W (FIRE) FIRE LANE 2" D I P W ( D O M ) 8" D I P W ( F I R E ) 4" D I P W ( F I R E ) CO CO CO CO6" PVC SEWER 6" P V C S E W E R 1 5 " R C P C L 1 V POROUSCONCRETE HE A V Y D U T Y AS P H A L T P A V I N G HEA V Y D U T Y ASP H A L T P A V I N G FIRE L A N R GV 8" P V C S D 18" RCP CL 1 V 24" HDPECL 1I1 6" P V C S E W E R DUMPSTERPAD 3 4 3 4 34 34 34 33 33 32 30 31 32 30 29 31 33 3 4 34 8" D I P W ( F I R E ) 8" D I P W ( F I R E ) 3 3 1 STORY LIBRARYFFE= 35.50 CB5 CB4 EW3 2 50 ' S E T B A C K 20' COCO CO CO C O CO C O CO DEPRESSED CURB 29 . 7 5 FOREBAY SHALLOWPOOL SHALLOWPOOL 20 ' 27' + 35.50 +35.50 + +36.00 + + 35.50 + +TC 34.93BC 34.43 + +35.44 35.50 +35.30 +TC 35.70BC 35.20 + TC 35.80BC 35.30 +TC 35.67BC 35.17 HP +++ + + +35.00+ + TC 35.08BC 34.58 + VAN + +TC 36.71BC 35.63 + + +36.81 HP + TC 35.45BC 34.95 +TC 35.24BC 34.74 +TC 35.34BC 34.84 +TC 35.56BC 35.06 + + TC 36.62BC 35.54 TC 35.62BC 35.54 +36.72 +35.72 +35.41 +35.50 + TC 35.46BC 35.38 +35.56 +35.71 TC 35.46BC 35.38 HP +34.68 + TC 35.42BC 34.92 TC 35.24BC 34.74 34.85 TC 35.46BC 34.96 TC 35.50BC 35.00 TC 35.41BC 34.91 TC 35.32BC 34.82 +34.95 35.44 + TC 34.85BC 34.35 34.50+ TC 35.45BC 34.95 +TC 35.30BC 34.80 TC 35.17BC 34.67 + TC 35.13BC 35.05 TC 35.36BC 34.86 +35.35 +35.27 TC 35.03BC 34.53 +34.92 +TC 35.70BC 35.20 HP HP HP LP 34.68+ 34.63+ HP HP TC 34.96BC 34.88 +35.37 +TC 3 5 . 5 5 BC 3 5 . 4 7 TC 35.98BC 35.48 +TC 35.98BC 35.48 +35.19+35.03 +TC 35.36BC 35.28 +TC 35.06BC 34.98 +TC 3 5 . 4 8 BC 3 5 . 4 0 +35.21 8 KB +35.50 +35.44 +35.50 +35.39 +TC 35.23BC 35.15 TC 35.29BC 35.21 36 3 5 35 35 35 35 35 FH-2 6" PVC W (FIRE) GV 8" D I P W ( F I R E ) 1 STORY LIBRARYFFE= 35.50 FIR E L A N E FIRE L A N E FI R E L A N E 15 " R C P C L 1 V 35 35 DI9 POROUSCONCRETE POROUSCONCRETE 20' DRAINAGE EASEMENT ++ C O C O C O CO CO CO LEGEND PROPERTY LINE EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK PROP. CONC. SIDEWALK PROP. STORM DRAIN PROP. WATER METER PROP. MILL & PAVE PROP. DOM. WATER BACK FLOW PREVENTER PROP. PERMEABLE CONCRETE PROP. STORMWATER WETLAND RELOCATED PARKING PAY STATION PROPOSED STREET LIGHT RELOCATED POWER POLE PROP. FIRE PROP. STORM MANHOLE PROP. SANITARY LINE PROP. SANITARY MANHOLE 8" SAN. PROP. POWER LINE P PPPPPPPPP PPPPPPPPPPPPP PPPPPPPPP PPPPPPPPP PPPPPPPPP PPPPPPPPP PROP. SMALL SWALE <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< co WM BFP REDUCED PRESSURE DETECTOR ASSEMBLY RPDA 2" W 4" F PROP. CLEANOUT PROP. FIRE HYDRANT PROP. WATER VALVE BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O PROP. FIRE DEPT. ACCESS PARKING SPACE COUNT 12 TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE PROPOSED SIGN X PROP. HEAVY DUTY ASPHALT PROP. HEAVY DUTYREINFORCED CONCRETE PROP. LANDSCAPE PAVERS FHFH WV S CO 19 20 T E LP T D PROP. RIP-RAP "GRASS-PAVE" SYSTEM PROP. TEE FITTING PROP. BEND FITTING PROP. REDUCER PROP. FIRE DEPT. ACCESSREINFORCED CONC. PAVERS C-201A GRADING PLAN BLOWUPS c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 SCALE 1" = 2000' 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 10ft. 5 1010 20 GRAPHIC SCALE ( IN FEET ) 16.5° GRADING BLOWUP #1 SCALE: 1"= 10' (HORIZ) GRADING BLOWUP #2 SCALE: 1"= 10' (HORIZ) GRADING BLOWUP #3 SCALE: 1"= 10' PROPOSED GRADING & STORMWATER MANAGMENT EASEMENT HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) 100 101 102 HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) T S S S S GVGV WV WVWV WV WVWV FI R E L A N E FIRE L A N E FI R E L A N E FIRE LANE FIRE LANE 20 ' FI R E L A N E FIRE L A N E DUMPSTERPAD 3 5 35 3 4 3 3 32 + 5 0 32+50 30 33 35 3331 35 35 35 36 15 " R C P C L I V 1 5 " R C P C L I V 18" RCP CL I V FDC FH-2 6" W 8" DIP W (FIRE) 6" D I P W 4" D I P W 6" P V C S E W E R 6" P V C S E W E R 6" PVC SEWER 35 HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y AS P H A L T P A V I N G HEA V Y D U T Y A S P H A L T PAV I N G POROUS CONCRETE POR O U S CON C R E T E 3 4 35 33 FI R E L A N E FIRE L A N E VAN 15 " R C P C L I V 15" RCP CL IV HE A V Y D U T Y AS P H A L T P A V I N G CA N O P Y 3 2 3032 32 3 3 34 33 33 30 3534 33 29 . 7 5 29 31 32 32 30 28.5 3 4 34 3 4 34 3 5 31 1 5 " R C P FOOT BRIDGE (BY OTHERS) PAVILLION(ADD-ALT.) 2" D I P W ( D O M ) BOOKDROP 8" D I P W ( F I R E ) 6" P V C S E W E R 6" P V C SE W E R 34 D O N O T E N T E R 8" D I P W ( F I R E ) 8" P V C S D P V C S D 8" 8" P V C S D 8" PVC SD 12" PVC SD 8" PVC SD CO 8" CO 8" PO R O U S C O N C R E T E PO R O U S C O N C R E T E EW1 CB2 EW3 CB4 CL lll HDPE24" CB5 DI6 CB7 DI8 DI9 2" D I P W ( D O M ) 20' (FI R E ) 2" D I P W ( D O M ) WM FH-1 GV RP D A RP 8" D I P W ( F I R E ) 3 4 6" P V C S E W E R EX1 30 31 CL I l l31 29.75 34 33 SWMWETLAND KB 1 STORY LIBRARY BUILDING FFE=35.50 COCO CO CO CO CO CO CO CO C O CO CO CO CO CO CO CO CO CO C O CO CO CO 28.5 33 2930. 5 29.75 29 . 7 5 30 32 30.5 30.5 30 30 29 29.7 5 28 31 32 32 . 5 31 31 31 30 FU T U R E M U L T I - U S E P A T H W A Y ( B Y O T H E R S ) 303029 30 29 28 28 30 31 32 31 33 30 29 . 7 5 30 29 . 7 5 30 SW M A C C E S S ( U N P A V E D ) SWM WETLAND FOREBAY FOREBAY FOREBAY DEEPPOOL DEEPPOOL DEEPPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL LEGEND PROPERTY LINE EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK PROP. CONC. SIDEWALK PROP. STORM DRAIN PROP. WATER METER PROP. MILL & PAVE PROP. DOM. WATER BACK FLOW PREVENTER PROP. PERMEABLE CONCRETE PROP. STORMWATER WETLAND RELOCATED PARKING PAY STATION PROPOSED STREET LIGHT RELOCATED POWER POLE PROP. FIRE PROP. STORM MANHOLE PROP. SANITARY LINE PROP. SANITARY MANHOLE 8" SAN. PROP. POWER LINE P PPPPPPPPP PPPPPPPPPPPPP PPPPPPPPP PPPPP PPPPPPPPPPPPP PPPPPPPPP PROP. SMALL SWALE <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< co WM BFP REDUCED PRESSURE DETECTOR ASSEMBLY RPDA 2" W 4" F PROP. CLEANOUT PROP. FIRE HYDRANT PROP. WATER VALVE BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O PROP. FIRE DEPT. ACCESS PARKING SPACE COUNT 12 TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE PROPOSED SIGN X PROP. HEAVY DUTY ASPHALT PROP. HEAVY DUTY REINFORCED CONCRETE PROP. LANDSCAPE PAVERS FHFH WV S CO 19 20 T E LP T D PROP. RIP-RAP "GRASS-PAVE" SYSTEM PROP. TEE FITTING PROP. BEND FITTING PROP. REDUCER PROP. FIRE DEPT. ACCESSREINFORCED CONC. PAVERS C-202 DRAINAGE AREA MAP c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30ft. 15 3030 60 GRAPHIC SCALE ( IN FEET ) 16.5° SCALE 1" = 2000' PROPOSED GRADING & STORMWATER MANAGMENT EASEMENT 15 20 25 30 35 40 45 15 20 25 30 35 40 45 0+00 33 . 7 0 EW 1 TOP WALL ELEV 30.75 CB 2 TOP ELEV 32.79 PROP. 15" RCP CL III @ 1.00% Q25 =1.73 CFS V = 5.28 FT/S 0+ 1 8 . 4 1 0+ 0 0 28 . 6 8 28 . 5 0 EXISTING GROUND PROPOSED GROUND 25-YR WSE 31.34 25-YR HGL OUTLET ELEV 28.50 15 20 25 30 35 40 45 15 20 25 30 35 40 45 0+00 1+00 2+00 32 . 0 2 32 . 6 0 33 . 1 3 33 . 5 9 33 . 8 9 34 . 2 5 34 . 7 1 34 . 6 4 34 . 7 7 EW 3 TOP WALL ELEV 32.42 CB 4 TOP ELEV 32.95 CB 5 TOP ELEV 33.29 CB 7 TOP ELEV 34.00 DI 6 TOP ELEV 33.79 PROP. 24" RCP CL III @ 0.75% Q25 = 9.42 CFS V = 6.26 FT/S PROP. 18" RCP CL IV @ 0.75% Q25 = 8.24 CFS V = 5.15 FT/S PROP. 15" RCP CL IV @ 0.50% Q25 = 2.05 CFS V = 3.72 FT/S PROP. 15" RCP CL IV @ 0.50% Q25 = 0.80 CFS V = 3.73 FT/S 0+ 1 9 . 2 1 0+ 0 0 28 . 6 5 28 . 5 0 0+ 8 9 . 1 3 0+ 0 0 30 . 2 6 29 . 5 9 0+ 4 1 . 3 0 0+ 0 0 30 . 7 2 30 . 5 1 0+ 5 1 . 7 5 0+ 0 0 31 . 0 8 30 . 8 2 EXISTING GROUNDPROPOSED GROUND 18" MIN." 6" DIP FIRE 2" DIP WAT 25-YR WSE 31.34 25-YR HGL 4" UNDERDRAIN INV. 31.17 (2) 4" UNDERDRAIN INV. 30.9615" RCP CL IV INV. 30.52 4" UNDERDRAIN INV. 30.46 OUTLET ELEV 28.50 8" P V C 30 . 4 2 15 20 25 30 35 40 45 15 20 25 30 35 40 45 0+00 1+00 2+00 33 . 9 9 34 . 2 4 34 . 6 4 35 . 0 5 34 . 8 2 34 . 8 2 34 . 6 5 34 . 7 9 CB 5 TOP ELEV 33.29 DI 8 TOP ELEV 34.00 DI 9 TOP ELEV 34.50 PROP. 15" RCP CL IV @ 0.60% Q25 = 3.12 CFS V = 4.07 FT/S PROP. 15" RCP CL IV @ 0.50% Q25 = 1.90 CFS V = 3.71 FT/S 1+ 0 2 . 1 0 0+ 0 0 31 . 1 3 30 . 5 2 0+ 7 4 . 4 7 0+ 0 0 31 . 6 0 31 . 2 3 EXISTING GROUND PROPOSEDGROUND 6" PVC SS 23.9" 25-YR HGL 4" UNDERDRAIN INV. 31.17 4" UNDERDRAIN INV. 31.68 15 " R C P I V IN I N V . 3 0 . 5 1 4" U N D E R D R A I N IN I N V . 3 0 . 4 6 15 " R C P I V OU T I N V . 3 0 . 2 6 STORM DRAINAGE STRUCTURE SCHEDULE NO. 1 2 3 4 5 6 7 8 9 TYPE PRECAST CONCRETE ENDWALL, NCDOT STD 838.80, SHEET C-502 CONCRETE CATCH BASIN, NCDOT STD 840.02, SHEET C-502 PRECAST CONCRETE ENDWALL, NCDOT STD 838.80, SHEET C-502 CONCRETE CATCH BASIN, NCDOT STD 840.02, SHEET C-502 CONCRETE CATCH BASIN, NCDOT STD 840.02, SHEET C-502 TRAFFIC BEARING DROP INLET, NCDOT STD 840.35, SHEET C-502 CONCRETE CATCH BASIN, NCDOT STD 840.02, SHEET C-502 TRAFFIC BEARING DROP INLET, NCDOT STD 840.35, SHEET C-502 TRAFFIC BEARING DROP INLET, NCDOT STD 840.35, SHEET C-502 SIZE IN 15" 24" 18" 8" 15" 15" 15" 15" INV. IN 28.50 28.50 29.59 30.42 30.51 30.52 30.82 31.23 SIZE OUT 15" 24" 18" 15" 15" 15" 15" INV. OUT 28.68 28.64 30.26 30.72 31.08 31.13 31.60 TOP ELEV 30.75 32.79 32.42 32.95 33.29 33.79 34.00 34.00 34.50 NORTHING 206794.9282 206785.6227 206708.6791 206714.3558 206759.4926 206771.3661 206820.9304 206671.8503 206645.8073 EASTING 2338456.0285 2338471.9078 2338403.9047 2338422.2577 2338499.1165 2338538.6700 2338523.7890 2338551.4871 2338621.2555 EW-1 CB-2 EW-3 CB-4 CB-5 DI-6 CB-7 DI-8 DI-9 4"31.68 4"31.68 4"31.68 4"31.17 15"4" (2) 30.82 30.96 31.2331.1715"4" 30.5130.5230.46 15"15"4" PIPE SCHEDULE RCP CLASS III RCP CLASS IV RCP CLASS IV HDPE CLASS III SIZE 8" 15" 15" 18" 24" MATERIAL LENGTH 13 LF 270LF 90 LF 12 LF 8" PVC 116 LF C-203 STORM DRAIN PROFILES c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30ft. 15 3030 60 GRAPHIC SCALE ( IN FEET ) CB-2 TO EW-1 SCALE: 1"= 30' (HORIZ) SCALE: 1" = 3' (VERT) CB-7 TO EW-3 SCALE: 1"= 30' (HORIZ) SCALE: 1" = 3' (VERT) DI-9 TO CB-5 SCALE: 1"= 30' (HORIZ) SCALE: 1" = 3' (VERT) HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) T S S S S 100 101 102 FI R E L A N E FIRE L A N E FI R E L A N E FIRE LANE FIRE LANE 20 ' FI R E L A N E FIRE L A N E DUMPSTERPAD HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y AS P H A L T P A V I N G HEAV Y D U T Y A S P H A L T PAV I N G POROUS CONCRETE POR O U S CON C R E T E FI R E L A N E FIRE L A N E HE A V Y D U T Y AS P H A L T P A V I N G CA N O P Y FOOT BRIDGE (BY OTHERS) PAVILLION(ADD-ALT.) BOOKDROP PO R O U S C O N C R E T E PO R O U S C O N C R E T E 20' SWMWETLAND KB 1 STORY LIBRARY BUILDING FFE=35.50 FU T U R E M U L T I - U S E P A T H W A Y ( B Y O T H E R S ) SW M A C C E S S ( U N P A V E D ) SWM WETLAND FOREBAY FOREBAY FOREBAY DEEPPOOL DEEPPOOL DEEPPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL DE P R E S S E D C U R B D E P R E S S E D C U R B T R A N S . DEPRESS E D C U R B TR A N S . T R A N S . NCDOT STD. 2'-6" CONC. CURB & GUTTER (TYP.) MILL & OVERLAY NCDOT STD. 2'-6" CONC. CURB & GUTTER (TYP.) NCDOT STD. 2'-6" CONC. CURB & GUTTER (TYP.) 6 C-501 8 C-501 CONCRETE WHEEL STOP (TYP. OF 8) CONCRETE BOLLARDS (TYP.) 8 EA. @4' O/C 5 C-501 ADA PARKING SIGNS (TYP.) OF 5 @4' O/C 8 C-500 VEHICULAR BRICK PAVERS 7 C-501 GRASS-PAVE FIRE LANE 2,3 C-501 DOUBLE DUMPSTER PAD, AND PAVING TIE-IN DETAILS 1 C-601 POROUS CONCRETE PAVING 1 C-601 POROUS CONCRETE PAVING 1 C-601 POROUS CONCRETE PAVING 7 C-500 DETECTABLE DOMES 5 C-500 REINFORCED CONCRETE 5 C-500 REINFORCED CONCRETE 6 C-500 DEPRESSED CURB 6 C-500 DEPRESSED CURB 1 C-500 1 C-500 NCDOT STD. 2'-6" CONC. CURB & GUTTER (TYP.) 1 C-500 3 C-500 5' CONCRETE SIDEWALK 3 C-500 CONCRETE SIDEWALK 3 C-500 CONCRETE SIDEWALK 3 C-500 CONCRETE SIDEWALK 1 STORY LIBRARY BUILDING FFE=35.50 PERMEABLE PAVERS PERMEABLE PAVERS 5 C-500 5' REINFORCED CONCRETE WALKWAY 7 C-501 GRASS-PAVE FIRE LANE DEPRESSED CURB DEPRESSED CURB DEPRESSED CURB 6" NOSED DOWN CURB 6" NOSED DOWN CURB LEGEND PROPERTY LINE EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK PROP. CONC. SIDEWALK PROP. STORM DRAIN PROP. WATER METER PROP. MILL & PAVE PROP. DOM. WATER BACK FLOW PREVENTER PROP. PERMEABLE CONCRETE PROP. STORMWATER WETLAND RELOCATED PARKING PAY STATION PROPOSED STREET LIGHT RELOCATED POWER POLE PROP. FIRE PROP. STORM MANHOLE PROP. SANITARY LINE PROP. SANITARY MANHOLE 8" SAN. PROP. POWER LINE PPPPPP PPPPPPPPP PPPPPPPPP PPPPPPPPPPPPP PPPPPPPPP PPPPP PPPPPPPP PROP. SMALL SWALE <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< co WM BFP REDUCED PRESSURE DETECTOR ASSEMBLY RPDA 2" W 4" F PROP. CLEANOUT PROP. FIRE HYDRANT PROP. WATER VALVE BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O PROP. FIRE DEPT. ACCESS PARKING SPACE COUNT 12 TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE PROPOSED SIGN X PROP. HEAVY DUTY ASPHALT PROP. HEAVY DUTY REINFORCED CONCRETE PROP. LANDSCAPE PAVERS FHFH WV S CO 19 20 T E LP T D PROP. RIP-RAP "GRASS-PAVE" SYSTEM PROP. TEE FITTING PROP. BEND FITTING PROP. REDUCER PROP. FIRE DEPT. ACCESSREINFORCED CONC. PAVERS C-300 PAVING PLAN c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30ft. 15 3030 60 GRAPHIC SCALE ( IN FEET ) 16.5° SCALE 1" = 2000' PROPOSED GRADING & STORMWATER MANAGMENT EASEMENT HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) T S S S S 100 101 102 GVGV WV WVWV WV WVWV 11 5 FI R E L A N E FIRE L A N E FI R E L A N E FIRE LANE FIRE LANE 20 ' FI R E L A N E FIRE L A N E DUMPSTERPAD HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y AS P H A L T P A V I N G HEAV Y D U T Y A S P H A L T PAV I N G POROUS CONCRETE POR O U S CON C R E T E FI R E L A N E FIRE L A N E VAN HE A V Y D U T Y AS P H A L T P A V I N G CA N O P Y 8 FOOT BRIDGE (BY OTHERS) PAVILLION(ADD-ALT.) BOOKDROP D O N O T E N T E R PO R O U S C O N C R E T E PO R O U S C O N C R E T E 20' SWMWETLAND KB 1 STORY LIBRARY BUILDING FFE=35.50 17202018 FU T U R E M U L T I - U S E P A T H W A Y ( B Y O T H E R S ) SW M A C C E S S ( U N P A V E D ) SWM WETLAND FOREBAY FOREBAY FOREBAY DEEPPOOL DEEPPOOL DEEPPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL WHITE MINI SKIP LINES4", 90 MIL, 3FT-9FT YELLOW DOUBLE LINES4", 90 MIL YELLOW DOUBLE LINES 4", 90 MIL 4" WHITE SOLID LINE (TYP.) 4" WHITE SOLID LINE(TYP.) 4" WHITESOLID LINE(TYP.) 4" WHITESOLID LINE(TYP.) 4" WHITE SOLID LINE(TYP.) 4" WHITESOLID LINE(TYP.) 4" WHITE SOLID LINE (TYP.) 24" WHITESTOP BAR 24" WHITESTOP BAR 24" WHITESTOP BAR 24" WHITE LINESAT 45° (TYP.) STOP RESERVED PARKING VAN ACCESSIBLE MAXIMUM PENALTY $250 STOP STOP STOP RESERVED PARKING MAXIMUM PENALTY $250 24" WHITESTOP BAR 24" WHITE STOP BAR DIRECTIONAL SIGNFOR BOOK DROP DIRECTIONAL SIGNFOR PATH USERS DIRECTIONAL SIGNFOR PATH USERS C-301 SIGNAGE & STRIPING PLAN c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30ft. 15 3030 60 GRAPHIC SCALE ( IN FEET ) 16.5° SCALE 1" = 2000' SIGNAGE SCHEDULE SIGN DESCRIPTION MUTCD CODE 4UANTITY MINIMUM SIGN MATERIAL STOP R1-1 5 30"X30"SHEET ALUMINUM (ASTM B209) RESERVED PARKING R7-8e 5 12"X26"SHEET ALUMINUM (ASTM B209) VAN ACCESSIBLE R7-8a 1 12"X6"SHEET ALUMINUM (ASTM B209) LEGEND PROPERTY LINE EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK PROP. CONC. SIDEWALK PROP. STORM DRAIN PROP. WATER METER PROP. MILL & PAVE PROP. DOM. WATER BACK FLOW PREVENTER PROP. PERMEABLE CONCRETE PROP. STORMWATER WETLAND RELOCATED PARKING PAY STATION PROPOSED STREET LIGHT RELOCATED POWER POLE PROP. FIRE PROP. STORM MANHOLE PROP. SANITARY LINE PROP. SANITARY MANHOLE 8" SAN. PROP. POWER LINE PPPPPPPPPPPPP PPPPP PPPPPPPPPPPPPPPPPPPPPP PPPPPPPPPPPPPPPPPP P PROP. SMALL SWALE <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< co WM BFP REDUCED PRESSURE DETECTOR ASSEMBLY RPDA 2" W 4" F PROP. CLEANOUT PROP. FIRE HYDRANT PROP. WATER VALVE BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O PROP. FIRE DEPT. ACCESS PARKING SPACE COUNT 12 TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE PROPOSED SIGN X PROP. HEAVY DUTY ASPHALT PROP. HEAVY DUTYREINFORCED CONCRETE PROP. LANDSCAPE PAVERS FHFH WV S CO 19 20 T E LP T D PROP. RIP-RAP "GRASS-PAVE" SYSTEM PROP. TEE FITTING PROP. BEND FITTING PROP. REDUCER PROP. FIRE DEPT. ACCESSREINFORCED CONC. PAVERS PROPOSED GRADING & STORMWATER MANAGMENT EASEMENT DIRECTIONAL SIGNS CUSTOM 3 CUSTOM SHEET ALUMINUM (ASTM B209) HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) T S S S S 100 101 102 GVGV WV WVWV WV WVWV FI R E L A N E FIR E L A N E FI R E L A N E FIRE LANE FIRE LANE 20 ' FI R E L A N E FIRE L A N E DUMPSTERPAD 15 " R C P C L I V 1 5 " R C P C L I V 18" RCP CL I V FDC FH-2 6" W 8" DIP W (FIRE) 6" D I P W 4" D I P W 6" P V C S E W E R 6" PV C S E W E R 6" PVC SEWER HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y AS P H A L T P A V I N G HEA V Y D U T Y A S P H A L T PAV I N G POROUS CONCRETE POR O U S CON C R E T E FI R E L A N E FIRE L A N E VAN 15 " R C P C L I V 15" RCP CL IV HE A V Y D U T Y AS P H A L T P A V I N G CA N O P Y 1 5 " R C P FOOT BRIDGE (BY OTHERS) PAVILLION(ADD-ALT.) 2" D I P W ( D O M ) BOOKDROP 8" D I P W ( F I R E ) 6" P V C S E W E R 6" P V C SE W E R D O N O T E N T E R 8" D I P W ( F I R E ) 8" P V C S D PV C S D 8" 8" P V C S D 8" PVC SD 12" PVC SD 8" PVC SD CO 8" CO 8" PO R O U S C O N C R E T E PO R O U S C O N C R E T E EW1 CB2 EW3 CB4 CL lll HDPE24" CB5 DI6 CB7 DI8 DI9 2" D I P W ( D O M ) 20' (FI R E ) 2" D I P W ( D O M ) WM FH-1 GV RP D A RP 8" D I P W ( F I R E ) 6" P V C S E W E R EX1 CL I l l SWMWETLAND KB 1 STORY LIBRARY BUILDING FFE=35.50 COCO CO CO CO CO CO C O CO CO CO CO CO CO CO CO CO C O C O CO CO C O CO FU T U R E M U L T I - U S E P A T H W A Y ( B Y O T H E R S ) SW M A C C E S S ( U N P A V E D ) SWM WETLAND FOREBAY FOREBAY FOREBAY DEEPPOOL DEEPPOOL DEEPPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL 2 C503 FIRE HYDRANT ASSEMBLY 2 C503 FIRE HYDRANT ASSEMBLY 4 C503 8" RPDA 8 C503 8"X8" TSV 1-1/2" WATER METER 5 C503 2" RPPA 2 C504 SANITARY CLEANOUT (TYP.) 2 C504 SANITARY CLEANOUT (TYP.) 6" SERVICE CONNECTION 1 C504 1 C503 LEGEND PROPERTY LINE EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK PROP. CONC. SIDEWALK PROP. STORM DRAIN PROP. WATER METER PROP. MILL & PAVE PROP. DOM. WATER BACK FLOW PREVENTER PROP. PERMEABLE CONCRETE PROP. STORMWATER WETLAND RELOCATED PARKING PAY STATION PROPOSED STREET LIGHT RELOCATED POWER POLE PROP. FIRE PROP. STORM MANHOLE PROP. SANITARY LINE PROP. SANITARY MANHOLE 8" SAN. PROP. POWER LINE PPPPPPPPPPPP PPPPP PPPPPPPPP PPPPPPPPPPPPP PPPPPPPPP PPPPPPPPP PP PROP. SMALL SWALE <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< co WM BFP REDUCED PRESSURE DETECTOR ASSEMBLY RPDA 2" W 4" F PROP. CLEANOUT PROP. FIRE HYDRANT PROP. WATER VALVE BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O PROP. FIRE DEPT. ACCESS PARKING SPACE COUNT 12 TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE PROPOSED SIGN X PROP. HEAVY DUTY ASPHALT PROP. HEAVY DUTY REINFORCED CONCRETE PROP. LANDSCAPE PAVERS FHFH WV S CO 19 20 T E LP T D PROP. RIP-RAP "GRASS-PAVE" SYSTEM PROP. TEE FITTING PROP. BEND FITTING PROP. REDUCER PROP. FIRE DEPT. ACCESSREINFORCED CONC. PAVERS C-400 UTILITY PLAN c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30ft. 15 3030 60 GRAPHIC SCALE ( IN FEET ) 16.5° SCALE 1" = 2000' 1 STORY LIBRARY BUILDING FFE=35.50 TIE INTO EX WATER MAIN 8"x6" T.S. & V TIE INTO EX WATER MAIN 8"x2" SADDLE 3' MIN. SEPARATION BETWEEN ALL FITTINGS PROPOSED GRADING & STORMWATER MANAGMENT EASEMENT 10 15 20 25 30 35 40 45 50 10 15 20 25 30 35 40 45 50 0+00 1+00 2+00 3+00 4+00 33 . 3 7 33 . 9 8 35 . 4 9 35 . 7 7 35 . 4 4 35 . 1 3 34 . 9 2 34 . 8 9 34 . 8 5 34 . 6 8 34 . 6 7 34 . 5 2 34 . 0 1 33 . 6 0 EX 1 TOP ELEV 34.12 0+ 9 9 . 9 4 0+ 0 0 26 . 7 5 25 . 7 5 0+ 7 2 . 8 9 0+ 0 0 27 . 4 8 26 . 7 5 0+ 9 0 . 6 3 0+ 0 0 29 . 2 9 27 . 4 8 0+ 2 5 . 2 7 0+ 0 0 29 . 8 0 29 . 2 9 0+ 1 3 . 1 5 0+ 0 0 30 . 0 6 29 . 8 0 EXISTING GROUND PROPOSED GROUND 15" RCP COCO CO CO CO (I N ) 8 " I N V 2 2 . 5 5 (O U T ) 8 " I N V 2 2 . 5 2 LIBRARY FFE=35.50 73 LF - 6" PVC @ 1.00% 91 LF - 6" PVC @ 2.00% 25 LF - 6" PVC @ 2.00% 13 LF - 6" PVC @ 2.00% 100 LF - 6" PVC @ 1.00% 23.9" 0+ 6 3 . 7 2 0+ 0 0 25 . 7 5 24 . 4 8 EX. 8" PVC SS 64 LF - 6" PVC @ 2.00% 30.3" 60"EX. 8"WATERMAIN(ASSUMEDDEPTH) 4" UNDERDRAIN 4" UNDERDRAIN 4" UNDERDRAIN SANITARY STRUCTURE SCHEDULE NO. EX-1 TYPE EXISTING MANHOLE SIZE IN 8" 8" INV. IN 24.48 22.55 SIZE OUT INV. OUT TOP ELEV 34.12 NORTHING 206971.5411 EASTING 2338632.23988"22.52 SANITARY PIPE SCHEDULE SIZE 6" MATERIAL LENGTH PVC (SCH. 40)366 LF 15 20 25 30 35 40 45 15 20 25 30 35 40 45 0+00 1+00 2+00 3+00 4+00 33 . 5 2 34 . 6 9 34 . 8 4 34 . 7 0 34 . 4 0 34 . 0 7 33 . 8 5 33 . 5 7 33 . 4 2 33 . 0 3 32 . 4 1 32 . 9 1 32 . 9 7 EXISTING GROUND PROPOSED GROUND 18" RCP 8" PVC SD 18" MIN" 8" DIP WATER 8" DIP WAT E R LIBRARY FFE = 35.30 18" MIN. 8"X8" TSV STA 0+00 4" DIP WATER 8"X4" REDUCER STA 2+74.95 8"X8" TEE" STA 2+66.708"X6" TEE (TO FH-1) STA 0+85.71 R/W 8" GV (2) STA 0+03.00 STA 0+11.29 15" RCP 18" MIN 4" UNDERDRAIN 15 20 25 30 35 40 45 15 20 25 30 35 40 45 0+00 1+00 2+00 32 . 8 9 33 . 3 2 33 . 8 7 34 . 3 5 35 . 7 9 36 . 0 3 8"X8" TEE STA 0+00 8" PVC SD 8" DIP WATER 8" DIP WATER 18" MIN. 18" MIN. 30" MIN. 8"X6" TEE (TO FH-2) STA 1+32.01 EXISTING GROUND PROPOSED GROUND WATER PIPE SCHEDULE DIP SIZE 2" 6" MATERIAL LENGTH 84 LF DIP 349 LF DIP8"451 LF 4"DIP 46 LF C-401 UTILITY PROFILES c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30ft. 15 3030 60 GRAPHIC SCALE ( IN FEET ) SANITARY SEWER PROFILE SCALE: 1"= 30' (HORIZ) SCALE: 1" = 3' (VERT) PRIVATE FIRE MAIN PROFILE (LEG 1) SCALE: 1"= 30' (HORIZ) SCALE: 1" = 3' (VERT) PRIVATE FIRE MAIN PROFILE (LEG 2) SCALE: 1"= 30' (HORIZ) SCALE: 1" = 3' (VERT) C-500 SITE DETAILS REINFORCED CONCRETE PAVING DETAIL5 6" S.H.A. MIX NO, 2 CONC W6 X 6 - #6/6 WWM 4" CRUSHED RUN (CR-6) BASE COURSE COMPACTED SUBGRADE NOTE: 1. EXPANSION JOINS SHALL BE AT THE LOCATIONS SHOWN ON THE PLANS. 2. MINIMUM 28 DAY COMPRESSIONS STRENGTH 4000psi. DETECTABLE DOMES (1 OF 2) SCALE: N.T.S. 7 12" L 12 " W 8" L 4" W 0.9" TO 1.4" 0.65" 0.20" 1.6" TO 2.4" 2" H CONCRETE BLOCKS MINIMUM (8) BLOCKS OF SIZE 12"W x 12"L x 2"H CLAY OR CONCRETE BRICKS MINIMUM (36) BRICKS OF SIZE 4"W x 8"L x 1/4"H NOTES DETECTABLE WARNING DOMES WILL COVER 2'-0" LENGTH AND FULL WIDTH OF THE RAMP FLOOR AS SHOWN ON THE DETAILS. 2. DETECTABLE WARNIING DOMES SHALL BE FEDERAL YELLOW IN COLOR. 3. PORTLAND CEMENT / SAND MIX 50% BY WEIGHT SAND. INSTALL AS DRY MIX. HAND TAMP FOR COMPACTION AND LEVEL BEFORE SETTING BRICKS. 4. BRICKS SHOULD BE BUTTED AS CLOSE TOGETHER AS ALLOWS. SWEEP PORTLAND CEMENT / SAND MIX INTO REMAINING CRACKS. 1. BASE DIAMETER 0.9"R TO 1.40"R TOP DIAMETER OF NO LESS THAN 50% TO NO MORE THAN 65% OF BASE DIAMETER 4' MINIMUM RAMP WIDTH 2' - 0 " L E N G T H 2' 0 " L E N G T H 4' MINIMUM RAMP WIDTH SEE NOTE 1 SEE NOTE 1 SE E N O T E 1 SE E N O T E 1 2 1/4" H DETECTABLE DOMES (2OF2) SCALE: N.T.S. NOTES CONTACT MANUFACTURER FOR SIZES AND SHAPES AVAILABLE IN ADDITION TO DETAILED INSTALLATION INSTRUCTIONS. 1. NYLON COMPOSITE CAST IN PLACE / REPLACEABLE ISOMETRIC SECTION A SECTION B SECTION C PLAN VIEW SEE MANUFACTURER FOR AVAILABLE SIZES (1' INTERVAL TYP.) SE E M A N U F A C T U R E R FO R A V A I L A B L E S I Z E S (1 ' I N T E R V A L T Y P . ) A B C 0.10" 0. 2 0 " 0. 0 5 " 0. 2 0 " 0.45 DIA. 0.90" DIA. 0.21" 0. 1 5 " 0.52" DIA. 0.27" DIA.0. 2 5 " 0. 2 5 " 0.14" 6" CO N C . SECTION B HEXAGONAL EMBEDMENT - ANCHOR SECTION C 2.35" 2. 3 5 " 7 6" 6" 2'-0" SCALE: N.T.S.6 COMPACTED GRADED AGGREGATE BASE (GAB) MIX No. 3 CONCRETE PAVEMENT WIDTH INDICATED ON TYPICAL STREET SECTIONS TO BE MEASURED TO THIS POINT FACE OF CURB 4.17% (SEE NOTE 2) STANDARD 2'-6" NCDOT CURB AND GUTTER (846.01) DEPRESSED CURB AT FIRE LANE, RAMPS AND ADA PARKING 1/2" R FLOW LINE NOTES: 1.A REVERSE GUTTER PAN SHALL HAVE A GUTTER SLOPE OF 4.17% AWAY FROM THE FLOW LINE, AND SHALL NOT BE USED WHERE THIS DRAINAGE CREATES A HAZARDOUS CONDITION. 2.GUTTER PAN AT THE MEDIAN EDGE OF INTERMEDIATE ARTERIALS OR THE HIGH SIDE OF SUPER ELEVATED SECTIONS SHALL BE SLOPED AT THE SAME RATE AND IN THE SAME DIRECTION AS THE PAVEMENT CROSS SLOPE. 3.A MINIMUM OF TWO FEET OF STABILIZED EARTH, SHALL SUPPORT ENTIRE BACK OF CURB. 4.POSITIVE DRAINAGE SHALL BE PROVIDED BOTH BEHIND THE CURB AND ALONG THE GUTTER & FLOW LINE. 6" 6" 7" 6" 1"BACK OF CURB PORTDAVEN HOME OFFICE WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 119 BROOKSTOWN AVE. SUITE PH1DEPRESSED CURB AND GUTTER 1 2 3 4 8 PAVERS BENEATH FRONT FIRE LANE MUST BE CONFIRMED TO SUPPORT 80,000 LBS. NOTE: c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 SCALE: N.T.S.9 10 UNILOCK ECO-PRIORIA PREMIER PAVER SERIES 2.75"THICK 1 1 REVISED PAVER DESCRIPTION 3/28/24 C-501 SITE DETAILS SAW CUT, TACK AND SEAL JOINT 2'-0" EX. PAVING PROPO. PAVING (SEE PAVING PLAN FOR DETAILS) SAWCUT & REMOVE EX. PAVING AS REQUIRED (TYPICAL) MILL 1 12" & OVERLAY WITH 1 12" - 9.5mm PG 64-22 LEVEL 1 TACK COAT PAVING TIE-IN DETAIL PORTDAVEN HOME OFFICE WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 119 BROOKSTOWN AVE. SUITE PH1SCALE: N.T.S. PORTDAVEN HOME OFFICE WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 119 BROOKSTOWN AVE. SUITE PH1 6" 10" 4" 6" 2"2" 4" 6" 2" 4" SCALE: N.T.S. NO. 6 REBAR W6X6 - #6/6 WWM S.H.A. MIX NO. 2 CONC.REINFORCED CONCRETE PAVING SEE DETAIL THIS SHEETPAVING SECTION SEE DETAIL THIS SHEET COMPACTED SUBGRADE NOTE: MINIMUM 28 DAY COMPRESSION STRENGTH 4000psi PORTDAVEN HOME OFFICE WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 119 BROOKSTOWN AVE. SUITE PH1 TIE IN FOR PAVING AND REINFORCED CONCRETE PAD SCALE: N.T.S.TIE IN AT EXPANSION JOINT COMPACTED SUBGRADE 1/2" SMOOTH STEEL DOWEL BAR SPACED AT 12" C/C REINFORCED CONCRETE PAVING SEE DETAIL THIS SHEET BITUMINOUS SEAL EXPANSION SLEEVE W6 X 6 - #6/6 WWM 3/4" PREMOULDED EXPANSION JOINT MATERIAL 1/4" R NOTE: 1.SMOOTH DOWELS SHALL BE PAINTED WITH APPROVED RED LEAD BEFORE DELIVERY AND FREE END SHALL BE GREASED BEFORE INSTALLATION. 6" 3" 2" 9"9" 2" 2" 3" 2" 1" 34" PORTDAVEN HOME OFFICE WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 119 BROOKSTOWN AVE. SUITE PH1 1/2" SQUARE GALVANIZED STEEL POST 3' - 0 " 3' - 6 " 9" Ø MIN. TYP. CONCRETE 7' - 0 " HANDICAP SIGN MOUNTING DETAIL NOT TO SCALE STOP 1/2" SQUARE GALVANIZED STEEL POST 3' - 0 " 3' - 6 " 9" Ø MIN. TYP. CONCRETE 7' - 0 " STANDARD SIGN MOUNTING DETAIL NOT TO SCALE RESERVED PARKING VAN ACCESSIBLE MAXIMUM PENALTY $250 SIGN MOUNTING DETAILS SCALE: N.T.S. SCALE: N.T.S.6' CONCRETE WHEEL STOP 6'-0" VARIES 5" (2) #3 REBAR GRADE 60 3/4" Ø HOLE FULL THICKNESS VARIES VARIES #4 BAR GRADE 60 ANCHOR PINS 14" LONG MIN. 3/4" Ø HOLE 2 PER WHEEL STOP 4 1/2" MIN. 6 1/2" MAX. 12 " HEAVY DUTY PAVING DETAIL1 1.5" ASPHALT SURFACE MIX, TYPE S9.5B 2.5" ASPHALT INTERMEDIATE MIX, TYPE I19.0C 8" NCDOT AGGREGATE BASE COURSE (ABC) TACK COAT COMPACT SUBGRADE SCALE: N.T.S. ROUND OFF CONCRETE 6" SCH STEEL PIPE STRONG STEEL PIPE BOLLARD CONC. FILLED 12" EXPANSION JOINT MATERIAL (TYP.) CONCRETE PAVING (TYP.) COMPATED SUBGRADE 8" SCH. 140 EXTRA STRONG STEEL PIPE SLEEVE 1'-0"SLOPE TO DRAIN AWAY (TYP.) S.H.A MIX No. 2 CONC. (TYP FOOTING) 8" 3'-0" 4'-0" 2" 2" PIPE BOLLARD SCALE: N.T.S. 1'-0" NOTE: CHOSEN GRASS-PAVE SYSTEM MUST BE CONFIRMED TO SUPPORT 80,000 LBS. FOR FIRE LANE ACCESS. c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 2 3 4 5 7 6 8 C-502 STORM DRAIN DETAILS c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 C-503 UTILITY DETAILS c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 1 2 3 4 5 6 7 8 C-504 UTILITY DETAILS c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 1 2 3 NORTHCHASE HOA MB 2117 PG 18 R02611-001-001-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) NORTHCHASE HOA MB 2117 PG 18 R02611-001-001-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) GVGV WV WVWV FI R E L A N E FIRE LANE 20 ' FI R E L A N E FIRE L A N E DUMPSTERPAD 3 4 3 3 32 + 5 0 32+50 30 33 1 5 " R C P C L I V 18" RCP CL I V HE A V Y D U T Y AS P H A L T P A V I N G HEA V Y D U T Y A S P H A L T PAV I N G POR O U S CON C R E T E 3 4 33 HE A V Y D U T Y AS P H A L T P A V I N G CA N O P Y 3 2 3032 32 3 3 34 33 33 30 3534 33 29 . 7 5 29 31 32 32 30 28.5 31 1 5 " R C P FOOT BRIDGE (BY OTHERS) BOOKDROP D O N O T E N T E R 8" P V C S D P V C S D 8" 8" P V C S D 8" PVC SD 12" PVC SD 8" PVC SD CO 8" 8" EW1 CB2 EW3 CB4 CL lll HDPE24" CB 20' 3 4 30 31 C L I l l31 29.75 34 33 SWMWETLAND KB 1 STORY LIBRARY BUILDING FFE=35.50 CO CO C O C O CO 28.5 33 2930. 5 29.75 29 . 7 5 30 32 30.5 30.5 30 30 29 29.7 5 28 31 32 32 . 5 31 31 31 30 FU T U R E M U L T I - U S E P A T H W A Y ( B Y O T H E R S ) 303029 30 29 28 28 30 31 32 31 33 30 29 . 7 5 30 29 . 7 5 30 SW M A C C E S S ( U N P A V E D ) SWM WETLAND FOREBAY FOREBAY FOREBAY DEEPPOOL DEEPPOOL DEEPPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL 0+ 0 0 1+ 0 0 2+ 0 0 3+ 0 0 4+00 4+61 20 25 30 35 40 20 25 30 35 40 0+00 1+00 2+00 3+00 4+00 32 . 1 4 31 . 5 4 31 . 5 0 31 . 8 2 32 . 6 3 29 . 2 9 29 . 2 1 29 . 0 9 28 . 9 9 29 . 2 2 29 . 4 2 29 . 3 2 30 . 1 9 31 . 7 4 32 . 0 0 32 . 6 2 33 . 3 1 33 . 7 3 33 . 8 5 EXISTING GROUND PROPOSED GROUND 15" RCP (2) IN V . 3 0 . 0 0 IN V . 3 0 . 4 5 OUTLET STRUCTURE TOP OF OUTLET BOX: 32.45 TOP OF RISER CREST: 30.94 SEE DETAILS ON SHEET C-602 1-YR WSE = 30.32 100-YR WSE = 31.87 25-YR WSE = 31.3410-YR WSE = 31.072-YR WSE = 30.74 LEGEND PROPERTY LINE EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK PROP. CONC. SIDEWALK PROP. STORM DRAIN PROP. WATER METER PROP. MILL & PAVE PROP. DOM. WATER BACK FLOW PREVENTER PROP. PERMEABLE CONCRETE PROP. STORMWATER WETLAND RELOCATED PARKING PAY STATION PROPOSED STREET LIGHT RELOCATED POWER POLE PROP. FIRE PROP. STORM MANHOLE PROP. SANITARY LINE PROP. SANITARY MANHOLE 8" SAN. PROP. POWER LINE PPPPPPP PPPPPPPPP PPPPPPPPPPPPP PPPPPPPPP PPPPP PPPPPPPPPPPPP PPP PROP. SMALL SWALE <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< co WM BFP REDUCED PRESSURE DETECTOR ASSEMBLY RPDA 2" W 4" F PROP. CLEANOUT PROP. FIRE HYDRANT PROP. WATER VALVE BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O PROP. FIRE DEPT. ACCESS PARKING SPACE COUNT 12 TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE PROPOSED SIGN X PROP. HEAVY DUTY ASPHALT PROP. HEAVY DUTY REINFORCED CONCRETE PROP. LANDSCAPE PAVERS FHFH WV S CO 19 20 T E LP T D PROP. RIP-RAP "GRASS-PAVE" SYSTEM PROP. TEE FITTING PROP. BEND FITTING PROP. REDUCER PROP. FIRE DEPT. ACCESSREINFORCED CONC. PAVERS C-600 STORMWATER MANAGEMENT PLAN c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 SCALE 1" = 2000' 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 2ft. 1 22 4 PROPOSED WETLAND PLAN SCALE: 1" = 20'' 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 20ft. 10 2020 40 PROPOSED WETLAND SECTION SCALE: 1" = 20' (HORIZ) SCALE: 1" = 2' (VERT) 16.5° PROPOSED GRADING & STORMWATER MANAGMENT EASEMENT FI R E L A N E FIR E L A N E FI R E L A N E FIRE LANE FIRE LANE 20 ' FI R E L A N E FIRE L A N E DUMPSTERPAD 3 5 35 3 4 3 3 32+50 30 35 35 35 36 15 " R C P C L I V 1 5 " R C P C L I V 18" RCP CL I V 35 HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y AS P H A L T P A V I N G HEA V Y D U T Y A S P H A L T PAV I N G POROUS CONCRETE POR O U S CON C R E T E 35 33 FI R E L A N E FIRE L A N E VAN 15 " R C P C L I V 15" RCP CL IV HE A V Y D U T Y AS P H A L T P A V I N G CA N O P Y 3032 32 3 3 34 3534 33 31 32 3 4 34 3 4 3 5 1 5 " R C P FOOT BRIDGE (BY OTHERS) PAVILLION(ADD-ALT.) BOOKDROP D O N O T E N T E R 8" P V C S D P V C S D 8" 8" P V C S D 8" PVC SD 12" PVC CO 8" CO 8" PO R O U S C O N C R E T E PO R O U S C O N C R E T E EW1 CB2 EW3 CB4 CL lll HDPE24" CB5 DI6 CB7 DI8 DI9 20' 3 4 30 31 C L I l l31 29.75 34 33 KB 1 STORY LIBRARY BUILDING FFE=35.50 CO CO C O C O C O C O C O C O C O C O C O C O C O C O C O C O C O CO 28.5 33 2930. 5 29.75 32 31 SWM WETLAND FOREBAY FOREBAY PERMEABLE PAVERS PE R M E A B L E PA V E R S 4" U N D E R D R A I N 4" U N D E R D R A I N 4" U N D E R D R A I N 4" U N D E R D R A I N UN D E R D R A I N 4" UNDE R D R A I N 4" UNDERDRAIN 4" 4" UNDERDRAIN LEGEND PROPERTY LINE EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK PROP. CONC. SIDEWALK PROP. STORM DRAIN PROP. WATER METER PROP. MILL & PAVE PROP. DOM. WATER BACK FLOW PREVENTER PROP. PERMEABLE CONCRETE PROP. STORMWATER WETLAND RELOCATED PARKING PAY STATION PROPOSED STREET LIGHT RELOCATED POWER POLE PROP. FIRE PROP. STORM MANHOLE PROP. SANITARY LINE PROP. SANITARY MANHOLE 8" SAN. PROP. POWER LINE PPPPPPP PPPPPPPPP PPPPPPPPP PPPPPPPPPPPPP PPPPPPPPP PPPPP PPPPPPP PROP. SMALL SWALE <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< co WM BFP REDUCED PRESSURE DETECTOR ASSEMBLY RPDA 2" W 4" F PROP. CLEANOUT PROP. FIRE HYDRANT PROP. WATER VALVE BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O PROP. FIRE DEPT. ACCESS PARKING SPACE COUNT 12 TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE PROPOSED SIGN X PROP. HEAVY DUTY ASPHALT PROP. HEAVY DUTYREINFORCED CONCRETE PROP. LANDSCAPE PAVERS FHFH WV S CO 19 20 T E LP T D PROP. RIP-RAP "GRASS-PAVE" SYSTEM PROP. TEE FITTING PROP. BEND FITTING PROP. REDUCER PROP. FIRE DEPT. ACCESSREINFORCED CONC. PAVERS C-601 STORMWATER MANAGEMENT PLAN c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 SCALE 1" = 2000' 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 2ft. 1 22 4 PROPOSED WETLAND PLAN SCALE: 1" = 20'' 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 20ft. 10 2020 40 16.5° SCALE: N.T.S. POROUS CONCRETE DETAIL 4" PERFORATED UNDERDRAIN RESERVOIR LAYER, AASHTO #3, #2, OR #57 STONE (AASHTO #57 TO BE USED ONLY WITH MAX. RESERVOIR DEPTH OF 8") OUTLET STANDARD STORM DRAIN INLET PAVEMENT ITEM DEPTH PERVIOUS PORTLAND CONCRETE 2 1 3 4 1 2 4 IN SITU SOIL 1% MIN. SLOPE 3 5 6 7 INLET SLOT WITH GALVANIZED OR STAINLESS STEEL GRATE (NOMINAL GRATE OPENINGS =1/2") UPTURNED PIPE SETS D 6 8 8 THREADED CAP FOR DEWATERING & MAINTENANCE WQ DEPTH OF AGGREGATE IN RESERVOIR LAYER NEEDED TO TREAT WATER QUALITY STORM DWQ= LEGEND 2 1 3 6" 5 24" 12" PAVEMENT DEPTH 7 SECTION NOTE: PERMEABLE PAVER DETAIL LOCATED ON LANDSCAPE PLANS 1 PROPOSED GRADING & STORMWATER MANAGMENT EASEMENT C-602 STORMWATER MANAGEMENT DETAILS c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 SCALE 1" = 2000' 3.00 0.17 DETAIL A: OUTLET STRUCTURE DETAILS 15" RCP PIPE INVERT=30.45 0.50 0.50 0.50 15" RCP 15" RCP 0.920.49 0.49 0.17 TOP OF RISER CREST ELEVATION=30.94 TOP OF RISER CREST ELEVATION=30.94 TOP OF OUTLET BOX ELEVATION=32.45 0.75 1.24 0.50 2.75 0.17 0.50 0.50 3.50 1.99 0.50 0.50 15" RCP ALUMINUM TRASH RACK WITH NO-FLOAT CLIPS TOP OF RISER CREST ELEVATION=30.94 15" RCP PIPE INVERT=30.45 1. 5 1 1.00 1.00 PRECAST OUTLET STRUCTURE BASE ELEVATION=28.95 P#57 ROCK BEDDING COURSE COMPACTED TO 95% PROCTOR ELEVATION=28.45 FILL BOTTOM OF BOX WITH CONCRETE FOR ANTI-FLOAT PRECAST OUTLET STRUCTURE BASE ELEVATION=28.95 P#57 ROCK BEDDING COURSE COMPACTED TO 95% PROCTOR ELEVATION=28.45 FILL BOTTOM OF BOX WITH CONCRETE FOR ANTI-FLOAT 15" RCP PIPE INVERT=30.45 TOP OF RISER CREST ELEVATION=30.94 1.99 3.50 0.50 15" RCP 1.00 1.51 TOP OF OUTLET BOX ELEVATION=32.45 4.00 15" RCP 15" RCP 4.40 5.40 4.00 5.00 CUSTOM PRECAST OUTLET BOX 5.00' X 5.40' 0.33 0.50 15" RCP 15" RCP 0.49 0.49 0.92 4.40 5.404.74 0.50 0.17 0.17 0.50 0.50 0.33 4.00 5.00 A A B B OUTLET PIPE TO PROTRUDE INTO OUTLET BOX, 6" MIN-18" MAX. CUSTOM PRECAST OUTLET BOX 5.00' X 5.40' FLOW DIRECTION FLOW DIRECTION PLAN VIEW A-A SECTION VIEW B-B SECTION VIEW FLOW DIRECTION AA BB FRONT VIEW TOP VIEW TOP OF BANK ELEV.=32.50 EM. SPILLWAY ELEV.=31.50 WOVEN GEOTEXTILE FABRIC 6' 12' 18' 6' 12' EL E V . = 3 2 . 5 0 ' EL E V . = 3 1 . 5 0 ' EL E V . = 3 1 . 5 0 ' EL E V . = 3 2 . 5 0 ' DETAIL C: EMERGENCY SPILLWAY CROSS SECTION 0.75 0.75 0.75 EMBANKMENT ELEV. @ RISER WALL=29.46 REMOVE EX. SKIMMER DEVICE FOR FINAL CONVERSION TO SWM. ELEV.=30.50 1.5" PVC0.32 EMBANKMENT SLOPE 3:1 3:1 1.00 0.17SKIMMER 1.5" PVC 2.20 CL SKIMMER 1.5" PVC 2.20 CLEANOUT ELEV.=29.25 OUTSIDE EDGE OF 4" WIDE STEEL PLATE CL OF 1" X1" STAINLESS STEEL TUBING FOR TRASH RACK (SEE TRASH RACK DETAILS SHEET EC-106) 3/8" X 4" STEEL PLATE (TYPICAL ALL SIDES) STAINLESS STEEL TRASH RACK (SEE DETAILS SHEET EC-106) 24° 3/8" X 4" STEEL PLATE (TYP. ALL SIDES) 24° OUTSIDE EDGE OF 4" WIDE STEEL PLATE CLASS 'B' RIPRAP UNDERLINED WITH WOVEN GEOTEXTILE FABRIC DETAIL D: EMERGENCY SPILLWAY PLAN VIEW NOTE: STORMWATER RISER STRUCTURE IS BEING INSTALLED UNDER THE ADVANCED SITE CONSTRUCTION, TO BE UTILIZED FOR SEDIMENT CONTROL. THE RISER WILL BE EXISTING AT TIME OF FINAL CONVERSION TO A STORMWATER MANAGEMENT FACILITY. MODIFICATIONS MAY BE REQUIRED AS SHOWN. REMOVE EX. SKIMMER DEVICE FOR FINAL CONVERSION TO SWM. ELEV.=30.50 HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) T S S S S 100 101 102 GVGV WV WV WV WV WVWV HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) 100 101 102 LEGEND PROPERTY LINE EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK PROP. CONC. SIDEWALK PROP. STORM DRAIN PROP. WATER METER PROP. MILL & PAVE PROP. DOM. WATER BACK FLOW PREVENTER PROP. PERMEABLE CONCRETE PROP. STORMWATER WETLAND RELOCATED PARKING PAY STATION PROPOSED STREET LIGHT RELOCATED POWER POLE PROP. FIRE PROP. STORM MANHOLE PROP. SANITARY LINE PROP. SANITARY MANHOLE 8" SAN. PROP. POWER LINE PPPP PPPPPPPPPPPPP PPPPPPPPP PPPPP PPPPPPPPPPPPP PPPPPPPPP PPPPPP PROP. SMALL SWALE <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< co WM BFP REDUCED PRESSURE DETECTOR ASSEMBLY RPDA 2" W 4" F PROP. CLEANOUT PROP. FIRE HYDRANT PROP. WATER VALVE BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O PROP. FIRE DEPT. ACCESS PARKING SPACE COUNT 12 TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE PROPOSED SIGN X PROP. HEAVY DUTY ASPHALT PROP. HEAVY DUTYREINFORCED CONCRETE PROP. LANDSCAPE PAVERS FHFH WV S CO 19 20 T E LP T D PROP. RIP-RAP "GRASS-PAVE" SYSTEM PROP. TEE FITTING PROP. BEND FITTING PROP. REDUCER PROP. FIRE DEPT. ACCESSREINFORCED CONC. PAVERS C-603 STORMWATER MANAGEMENT EXISTING PEAK FLOW c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30ft. 15 3030 60 GRAPHIC SCALE ( IN FEET ) 16.5° SCALE 1" = 2000' LEGEND HYDRAULIC FLOW LINE DRAINAGE AREA BOUNDARY SOIL BOUNDARY POI A TOTAL AREA: 6.21 WEIGHTED CN: 83 Tc: 36.8 MIN DA-1 IMPERVIOUS: 0.04 AC OPEN SPACE: 2.83 AC TOTAL: 2.87 AC CN: 54 Tc: 36.8 MIN DA-3 (OFFSITE RUNOFF) IMPERVIOUS: 1.80 AC OPEN SPACE: 0.57 AC TOTAL: 2.37 AC CN: 96 Tc: 5.0 MIN POI B TOTAL AREA: 2.30 WEIGHTED CN: 62 Tc: 40.0 MIN DA-2 IMPERVIOUS: 0.34 AC OPEN SPACE: 1.96 AC TOTAL: 2.30 AC CN: 77 Tc: 40.0 MIN POI C TOTAL AREA: 2.37 WEIGHTED CN: 96 Tc: 5.0 MIN HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) 100 101 102 HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) T S S S S 100 101 102 GVGV WV WVWV WV WVWV FI R E L A N E FIRE L A N E FI R E L A N E FIRE LANE FIRE LANE 20 ' FI R E L A N E FIRE L A N E DUMPSTERPAD 3 5 35 3 4 3 3 32 + 5 0 32+50 30 33 35 3331 35 35 35 36 15 " R C P C L I V 1 5 " R C P C L I V 18" RCP CL I V 35 HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y AS P H A L T P A V I N G HEA V Y D U T Y A S P H A L T PAV I N G POROUS CONCRETE POR O U S CON C R E T E 3 4 35 33 FI R E L A N E FIRE L A N E VAN 15 " R C P C L I V 15" RCP CL IV HE A V Y D U T Y AS P H A L T P A V I N G CA N O P Y 3 2 3032 32 3 3 34 33 33 30 3534 33 29 . 7 5 29 31 32 32 30 28.5 3 4 34 3 4 34 3 5 31 1 5 " R C P FOOT BRIDGE (BY OTHERS) PAVILLION(ADD-ALT.) BOOKDROP 34 D O N O T E N T E R 8" P V C S D P V C S D 8" 8" P V C S D 8" PVC SD 12" PVC SD 8" PVC SD CO 8" CO 8" PO R O U S C O N C R E T E PO R O U S C O N C R E T E EW1 CB2 EW3 CB4 CL lll HDPE24" CB5 DI6 CB7 DI8 DI9 20' 3 4 30 31 CL I l l31 29.75 34 33 SWMWETLAND KB 1 STORY LIBRARY BUILDING FFE=35.50 CO CO CO CO CO CO CO C O CO CO CO CO CO CO C O CO CO CO 28.5 33 2930. 5 29.75 29 . 7 5 30 32 30.5 30.5 30 30 29 29.7 5 28 31 32 32 . 5 31 31 31 30 FU T U R E M U L T I - U S E P A T H W A Y ( B Y O T H E R S ) 303029 30 29 28 28 30 31 32 31 33 30 29 . 7 5 30 29 . 7 5 30 SW M A C C E S S ( U N P A V E D ) SWM WETLAND FOREBAY FOREBAY FOREBAY DEEPPOOL DEEPPOOL DEEPPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL LEGEND PROPERTY LINE EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK PROP. CONC. SIDEWALK PROP. STORM DRAIN PROP. WATER METER PROP. MILL & PAVE PROP. DOM. WATER BACK FLOW PREVENTER PROP. PERMEABLE CONCRETE PROP. STORMWATER WETLAND RELOCATED PARKING PAY STATION PROPOSED STREET LIGHT RELOCATED POWER POLE PROP. FIRE PROP. STORM MANHOLE PROP. SANITARY LINE PROP. SANITARY MANHOLE 8" SAN. PROP. POWER LINE PPPPPPP PPPPPPPPP PPPPPPPPP PPPPPPPPP PPPPPPPPPPPPP PPPPPPPPP PPP PROP. SMALL SWALE <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< co WM BFP REDUCED PRESSURE DETECTOR ASSEMBLY RPDA 2" W 4" F PROP. CLEANOUT PROP. FIRE HYDRANT PROP. WATER VALVE BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O PROP. FIRE DEPT. ACCESS PARKING SPACE COUNT 12 TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE PROPOSED SIGN X PROP. HEAVY DUTY ASPHALT PROP. HEAVY DUTYREINFORCED CONCRETE PROP. LANDSCAPE PAVERS FHFH WV S CO 19 20 T E LP T D PROP. RIP-RAP "GRASS-PAVE" SYSTEM PROP. TEE FITTING PROP. BEND FITTING PROP. REDUCER PROP. FIRE DEPT. ACCESSREINFORCED CONC. PAVERS C-604 STORMWATER MANAGEMENT POST PEAK FLOW c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30ft. 15 3030 60 GRAPHIC SCALE ( IN FEET ) 16.5° SCALE 1" = 2000' LEGEND HYDRAULIC FLOW LINE DRAINAGE AREA BOUNDARY SOIL BOUNDARY POI B TOTAL AREA: 5.38 WEIGHTED CN: 91 Tc: 11.1 MIN DA-1 IMPERVIOUS: 1.41 AC OPEN SPACE: 0.63 AC POROUS CONCRETE: 0.36 TOTAL: 2.40 AC CN: 90 Tc: 7.4 MIN DA-2 IMPERVIOUS: 0.19 AC OPEN SPACE: 0.42 AC TOTAL: 0.61 AC CN: 79 Tc: 11.1 MIN DA-3 (OFFSITE RUNOFF) IMPERVIOUS: 1.80 AC OPEN SPACE: 0.57 AC TOTAL: 2.37 AC CN: 96 Tc: 5.0 MIN POI A TOTAL AREA: 2.09 WEIGHTED CN: 83 Tc: 9.7 MIN POI B TOTAL AREA: 2.37 WEIGHTED CN: 96 Tc: 5.0 MIN DA-2 IMPERVIOUS: 0.27 AC OPEN SPACE: 0.58 AC TOTAL: 2.09 AC CN: 83 Tc: 9.7 MIN PROPOSED GRADING & STORMWATER MANAGMENT EASEMENT T S S S S GVGV WV WVWV WV WVWV X XX HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) SF SF SF SF SF SF SF SF SSF SSF SSF SSF SSF SSF SF SF S F SF SF SF SF SF SF S F SF SF SF SF SF SF SF MB CW CE CS CSCSCSCS REINFORCED CONCRETERISER W/ SKIMMER DEVICE SB TE M P O R A R Y ST O C K P I L E A R E A 2:12:1 3 BAFFLESSPACED 95'ON CENTER SKIMMER BASIN #1TOP OF POND ELEVATION = 32.50SPILLWAY/RISER CREST ELEVATION= 31.94SKIMMER ELEVATION = 30.50SKIMMER ARM LENGTH = 5.0'SKIMMER PIPE DIAMETER = 1.50"SKIMMER ORIFICE DIAMETER = 0.60"(DESIGNED FOR FAIRCLOTH SKIMMER)SEDIMENT STORAGE BOTTOM = 28.00POND LENGTH AT SPILLWAY ELEVATION = 394'POND WIDTH AT SPILLWAY ELEVATION = 23' (AVG.) DRAINAGE AREA TO SWALE A=2.90 AC. / C=0.71 I=5.58 / Q=11.49 CFS. SILT FENCE 88 LF SLOPE  2 A=0.02 AC COMPOST SOCK 103 LF SLOPE  2 A=0.07 AC SILT FENCE 51 LF SLOPE  2 A=0.01 AC 1- STORY BUILDING PAD FFE ELEV.=35.50 SPECIAL SILT FENCE 404 LF SLOPE =2 A=0.31 AC LOD LO D LO D LOD LODLODLODLODLODLOD LOD LOD LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LOD LOD LOD LO D LO D LOD LOD LOD LO D L O D LOD LOD LOD LO D LOD LOD LO D LO D LO D LO D LO D LO D LO D LO D SKIMMER BASIN 1 C=0.50 A=2.42 AC LAYDOWN AREA SUPER SILT FENCE 510 LF SLOPE  2 A=0.29 AC SF SF SSF SSF SS F SS F SS F SSFSSF SSF SS F SS F SS F SS F SS F SS F SS F SS F SS F SS F SS F LEGEND EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE X FHFH WV S CO 19 20 T E LP T EC-100 EROSION AND SEDIMENTCONTROL PLAN FOR INITIAL CONDITON TREE PROTECTION LIMITS OF DISTURBANCE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE (WITH TIRE WASH) KEY SYMBOL DESCRIPTION DIVERSION FENCE SILT FENCE RISER SKIMMER BASIN RIP-RAP INFLOW PROTECTION CONCRETE WASHOUT COMPOST SOCKCSCS MOUNTABLE BERM FILTER BAGFB EROSION/SEDIMENT CONTROL LEGEND DRAINAGE DIVIDE TEMPORARY PIPE c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30ft. 15 3030 60 GRAPHIC SCALE ( IN FEET ) 16.5° SCALE 1" = 2000' PROPOSED GRADING & STORMWATER MANAGMENT EASEMENT T S S S S GVGV WV WVWV WV WVWV HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) FI R E L A N E FIRE L A N E FI R E L A N E FIRE LANE FIRE LANE 20 ' FI R E L A N E FIRE L A N E DUMPSTERPAD 15 " R C P C L I V 1 5 " R C P C L I V 18" RCP CL I V FDC FH-2 6" W 8" DIP W (FIRE) 6" D I P W 4" D I P W 6" P V C S E W E R 6" P V C S E W E R 6" PVC SEWER HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y AS P H A L T P A V I N G HEAV Y D U T Y A S P H A L T PAV I N G POROUS CONCRETE POR O U S CON C R E T E FI R E L A N E FIRE L A N E 15 " R C P C L I V 15" RCP CL IV HE A V Y D U T Y AS P H A L T P A V I N G CA N O P Y 1 5 " R C P FOOT BRIDGE (BY OTHERS) PAVILLION(ADD-ALT.) 2" D I P W ( D O M ) BOOKDROP 8" D I P W ( F I R E ) 6" P V C S E W E R 6" P V C SE W E R 8" D I P W ( F I R E ) 8" P V C S D P V C S D 8" 8" P V C S D 8" PVC SD 12" PVC SD 8" PVC SD CO 8" CO 8" PO R O U S C O N C R E T E PO R O U S C O N C R E T E CL lll HDPE24" 2" D I P W ( D O M ) 20' (FI R E ) 2" D I P W ( D O M ) WM FH-1 GV RP D A RP 8" D I P W ( F I R E ) 6" P V C S E W E R EX1 CL I l l KB 1 STORY LIBRARY BUILDING FFE=35.50 COCO CO CO CO CO CO CO CO C O CO CO CO CO CO CO CO CO CO C O CO CO CO FFE=35.50 1 STORY LIBRARY BUILDING MB CW CE CS CSCSCSCS SF SF REINFORCED CONCRETERISER W/ SKIMMER DEVICE SB TE M P O R A R Y ST O C K P I L E A R E A 2:12:1 S F SF SF SF SFSF 3 BAFFLESSPACED 95'ON CENTER SKIMMER BASIN #1TOP OF POND ELEVATION = 32.50SPILLWAY/RISER CREST ELEVATION= 31.94SKIMMER ELEVATION = 30.50SKIMMER ARM LENGTH = 5.0'SKIMMER PIPE DIAMETER = 1.50"SKIMMER ORIFICE DIAMETER = 0.60"(DESIGNED FOR FAIRCLOTH SKIMMER)SEDIMENT STORAGE BOTTOM = 28.00POND LENGTH AT SPILLWAY ELEVATION = 394'POND WIDTH AT SPILLWAY ELEVATION = 23' (AVG.) SF SF SF SF SF DRAINAGE AREA TO SWALE A=2.90 AC. / C=0.71 I=5.58 / Q=11.49 CFS. SILT FENCE 88 LF SLOPE  2 A=0.02 AC COMPOST SOCK 103 LF SLOPE  2 A=0.07 AC SILT FENCE 51 LF SLOPE  2 A=0.01 AC 1- STORY BUILDING PAD FFE ELEV.=35.50 SPECIAL SILT FENCE 404 LF SLOPE =2 A=0.31 AC SSF SS F SSF SSF SSF SSF SSF SSF SS F SS F SSF SKIMMER BASIN 1 C=0.50 A=2.42 AC LAYDOWN AREA IP IP IPIP IP IP IP LOD LO D L O D LOD LODLODLODLODLODLOD LOD LOD LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LOD LOD LOD LO D LO D LOD LOD LOD LO D L O D LOD LO D LOD LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D SSFSSF SSF SS F SS F SS F SS F SS F SS F SS F SS F SS F SS F SS F SUPER SILT FENCE 510 LF SLOPE  2 A=0.29 AC LEGEND EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE X FHFH WV S CO 19 20 T E LP T EC-101 EROSION AND SEDIMENTCONTROL PLAN FOR INTERIM CONDITON TREE PROTECTION LIMITS OF DISTURBANCE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE (WITH TIRE WASH) KEY SYMBOL DESCRIPTION DIVERSION FENCE SILT FENCE RISER SKIMMER BASIN RIP-RAP INFLOW PROTECTION CONCRETE WASHOUT COMPOST SOCKCSCS MOUNTABLE BERM FILTER BAGFB EROSION/SEDIMENT CONTROL LEGEND DRAINAGE DIVIDE TEMPORARY PIPE c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30ft. 15 3030 60 GRAPHIC SCALE ( IN FEET ) 16.5° SCALE 1" = 2000' PROPOSED GRADING & STORMWATER MANAGMENT EASEMENT HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) T S S S S GVGV WV WVWV WV WVWV HOSKINS TOM MB 5160 PG 1614 PID: R02611-001-017-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-005-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 ZONING: PD GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02612-003-011-000 ZONING: PD NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 ZONING: PD CAMP GROUP, LLC MB 5705 PG 1983 PID: R02612-002-009-000 ZONING: PD NEW HANOVER COUNTY MB 2081 PG 285 R02611-002-001-000 ZONING: PD (TO BE DEDICATED AS PERMANENT GRADING AND STORMWATER MANAGMENT EASEMENT) 11 5 FI R E L A N E FIRE L A N E FI R E L A N E FIRE LANE FIRE LANE 20 ' FI R E L A N E FIRE L A N E DUMPSTERPAD 3 5 35 3 4 3 3 32 + 5 0 32+50 30 33 35 3331 35 35 35 36 15 " R C P C L I V 1 5 " R C P C L I V 18" RCP CL IV FDC FH-2 6" W 8" DIP W (FIRE) 6" D I P W 4" D I P W 6" P V C S E W E R 6" P V C S E W E R 6" PVC SEWER 35 HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y A S P H A L T P A V I N G HE A V Y D U T Y AS P H A L T P A V I N G HEAV Y D U T Y A S P H A L T PAV I N G CO N C R E T E P A V E R S POROUS CONCRETE POR O U S CON C R E T E CONCRETE BIKE PATH 3 4 35 33 CONCRETE CONCRETE FI R E L A N E FIRE L A N E VAN 15 " R C P C L I V 15" RCP CL IV HE A V Y D U T Y AS P H A L T P A V I N G CA N O P Y CO N C R E T E WA L K CONC. WALK CO N C . W A L K 3 2 3032 32 33 34 33 33 30 35 8 FOOT BRIDGE 34 33 29 . 7 5 29 31 32 32 30 28.5 34 34 3 4 34 3 5 31 1 5 " R C P FOOT BRIDGE (BY OTHERS) PAVILLION(ADD-ALT.) 2" D I P W ( D O M ) BOOKDROP 8" D I P W ( F I R E ) 6" P V C S E W E R 6" P V C SE W E R 34 D O N O T E N T E R 8" D I P W ( F I R E ) 8" P V C S D PV C S D 8" 8" P V C S D 8" PVC SD 12" PVC SD 8" PVC SD CO 8" CO 8" PO R O U S C O N C R E T E PO R O U S C O N C R E T E EW1 CB2 EW3 CB4 CL lll HDPE24" CB5 DI6 CB7 DI8 DI9 2" D I P W ( D O M ) 20' (FI R E ) 2" D I P W ( D O M ) WM FH-1 GV RP D A RP 8" D I P W ( F I R E ) 3 4 6" P V C S E W E R EX1 30 31 CL I l l31 29.75 34 33 SWMWETLAND KB 1 STORY LIBRARY BUILDING FFE=35.50 COCO CO CO CO CO CO C O CO C O CO CO CO CO CO 17202018 CO CO CO CO CO CO CO CO 28.5 33 2930. 5 29.75 29 . 7 5 30 32 30.5 30.5 30 30 29 29.7 5 28 31 32 32 . 5 31 31 31 30 FU T U R E M U L T I - U S E P A T H W A Y ( B Y O T H E R S ) 303029 30 29 28 28 30 31 32 31 33 30 29 . 7 5 30 29 . 7 5 30 SW M A C C E S S ( U N P A V E D ) SWM WETLAND FOREBAY FOREBAY FOREBAY DEEPPOOL DEEPPOOL DEEPPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL SHALLOWPOOL MB CW CE CS CSCSCSCS SF SF REINFORCED CONCRETERISER W/ SKIMMER DEVICE SB TE M P O R A R Y ST O C K P I L E A R E A 2:12:1 S F SF SF SF SFSF 3 BAFFLESSPACED 95'ON CENTER SKIMMER BASIN #1TOP OF POND ELEVATION = 32.50SPILLWAY/RISER CREST ELEVATION= 31.94SKIMMER ELEVATION = 30.50SKIMMER ARM LENGTH = 5.0'SKIMMER PIPE DIAMETER = 1.50"SKIMMER ORIFICE DIAMETER = 0.60"(DESIGNED FOR FAIRCLOTH SKIMMER)SEDIMENT STORAGE BOTTOM = 28.00POND LENGTH AT SPILLWAY ELEVATION = 394'POND WIDTH AT SPILLWAY ELEVATION = 23' (AVG.) SF SF SF S F S F DRAINAGE AREA TO SWALE A=2.90 AC. / C=0.71 I=5.58 / Q=11.49 CFS. SILT FENCE 88 LF SLOPE  2 A=0.03 AC COMPOST SOCK 103 LF SLOPE  2 A=0.07 AC SILT FENCE 51 LF SLOPE  2 A=0.01 AC 1- STORY BUILDING PAD FFE ELEV.=35.50 SPECIAL SILT FENCE 404 LF SLOPE =2 A=0.31 AC SSF SS F SSF SSF SSF SSF SSF SSF S S F SS F SSF SKIMMER BASIN 1 C=0.50 A=2.42 AC LAYDOWN AREA IP IP IPIP IP IP IP LOD LO D LO D LOD LODLODLODLODLODLO D LOD LOD LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LOD LOD LOD LOD LOD LO D LOD LOD LOD LO D LOD LO D LO D LO D LO D LO D LOD LO D LO D LO D LO D LO D LO D LO D LO D SSFSSF SSF SS F SS F SS F SS F SS F SS F SS F SS F SS F SS F SS F SUPER SILT FENCE 510 LF SLOPE  2 A=0.35 AC SF SF SF SF SFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SF S F SF SF SF SF SF SF LEGEND EX. PROPERTY CORNER EX DRAINAGE MANHOLE EX CATCH BASIN EX STORM SEWER (AS NOTED) EX WATER METER EX FIRE HYDRANT EX WATER VALVE EX WATER MANHOLE EX ELECTRIC MANHOLE EX UTILITY POLE EX OVERHEAD ELECTRIC EX SANITARY MANHOLE EX GRATE INLET EX LIGHT POLE EX WATER LINE EX U/G ELECTRIC E SURVEYED RIGHT-OF-WAY LINE EX LANDSCAPING EX SIDEWALK EX FENCE EX BOUNDARY LINE X EX SANITARY SEWER EX CLEANOUT EX U/G TELEPHONE LINE T EX SIGN EX BOLLARD EX FLAGPOLE EX CONTOURS EX TREE EX BUSH SURVEY BENCHMARK BARB WIRE BW END OF INFORMATION EOI PIPE DIRECTION PD STORM MANHOLE STMH SANITARY SEWER MANHOLE SSMH LITTLE FREE LIBRARY LFL CURB & GUTTER C&G EDGE OF PAVEMENT EOP VINYL FENCE VF EEX ELECTRIC BOX EX TRANSFORMER EX TELEPHONE PEDESTAL EX FIBER OPTIC LINE F/O TCP DIP RCP PVC CPP CLF BF TERRA COTTA PIPE DUCTILE IRON PIPE REINFORCED CONCRETE PIPE POLYVINYL CHLORIDE PIPE CORRUGATED PLASTIC PIPE CHAIN LINK FENCE BOARD FENCE X FHFH WV S CO 19 20 T E LP T EC-102 EROSION AND SEDIMENTCONTROL PLAN FOR FINAL CONDITON TREE PROTECTION LIMITS OF DISTURBANCE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE (WITH TIRE WASH) KEY SYMBOL DESCRIPTION DIVERSION FENCE SILT FENCE RISER SKIMMER BASIN RIP-RAP INFLOW PROTECTION CONCRETE WASHOUT COMPOST SOCKCSCS MOUNTABLE BERM FILTER BAGFB EROSION/SEDIMENT CONTROL LEGEND DRAINAGE DIVIDE TEMPORARY PIPE c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 JOH N J A Y B U R N E R JR FW Y M I C H A E L J O R D A N P W Y SITE VICINITY MAP HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30ft. 15 3030 60 GRAPHIC SCALE ( IN FEET ) 16.5° SCALE 1" = 2000' PROPOSED GRADING & STORMWATER MANAGMENT EASEMENT 3. 0 0 ' 0.17' DETAIL A: OUTLET STRUCTURE DETAILS 15" RCP PIPE INVERT=30.45 0. 5 0 ' 0.50'0.50' 15" R C P 15" R C P 0.92'0.49'0.49' 0.17' TOP OF RISER CREST ELEVATION=30.94 TOP OF RISER CREST ELEVATION=30.94 TOP OF OUTLET BOX ELEVATION=32.45 0. 7 5 ' 1. 2 4 ' 0. 5 0 ' 2. 7 5 ' 0.17' 0.50'0.50' 3. 5 0 ' 1. 9 9 ' 0. 5 0 ' 0. 5 0 ' 15 " R C P ALUMINUM TRASH RACK WITH NO-FLOAT CLIPS TOP OF RISER CREST ELEVATION=30.94 15" RCP PIPE INVERT=30.45 1. 5 1 ' 1.00'1.00' PRECAST OUTLET STRUCTURE BASE ELEVATION=28.95 P#57 ROCK BEDDING COURSE COMPACTED TO 95% PROCTOR ELEVATION=28.45 FILL BOTTOM OF BOX WITH CONCRETE FOR ANTI-FLOAT PRECAST OUTLET STRUCTURE BASE ELEVATION=28.95 P#57 ROCK BEDDING COURSE COMPACTED TO 95% PROCTOR ELEVATION=28.45 FILL BOTTOM OF BOX WITH CONCRETE FOR ANTI-FLOAT 15" RCP PIPE INVERT=30.45 TOP OF RISER CREST ELEVATION=30.94 1. 9 9 ' 3. 5 0 ' 0. 5 0 ' 15 " R C P 1.00' 1. 5 1 ' TOP OF OUTLET BOX ELEVATION=32.45 4.00' 15 " R C P 15 " R C P 4. 4 0 ' 5. 4 0 ' 4.00' 5.00' CUSTOM PRECAST OUTLET BOX 5.00' X 5.40' 0.33' 0.50' 15 " R C P 15 " R C P 0. 4 9 ' 0. 4 9 ' 0. 9 2 ' 4. 4 0 ' 5. 4 0 ' 4. 7 4 ' 0. 5 0 ' 0. 1 7 ' 0. 1 7 ' 0. 5 0 ' 0.50' 0.33' 4.00' 5.00' A A B B OUTLET PIPE TO PROTRUDE INTO OUTLET BOX, 6" MIN-18" MAX. CUSTOM PRECAST OUTLET BOX 5.00' X 5.40' FLOW DIRECTION FLOW DIRECTION PLAN VIEW A-A SECTION VIEW B-B SECTION VIEW FLOW DIRECTION AA BB FRONT VIEW TOP VIEW TOP OF BANK ELEV.=32.50 EM. SPILLWAY ELEV.=31.50 WOVEN GEOTEXTILE FABRIC 6' 12' 18' 6' 12' EL E V . = 3 2 . 5 0 ' EL E V . = 3 1 . 5 0 ' EL E V . = 3 1 . 5 0 ' EL E V . = 3 2 . 5 0 ' DETAIL C: EMERGENCY SPILLWAY CROSS SECTION DETAIL D: EMERGENCY SPILLWAY PLAN VIEW CLASS 'B' RIPRAP UNDERLINED WITH WOVEN GEOTEXTILE FABRIC 0. 7 5 ' 0. 7 5 ' 0. 7 5 ' EMBANKMENT ELEV. @ RISER WALL=29.46 SKIMMER ELEV.=30.50 1.5" PVC0. 3 2 ' EMBANKMENT SLOPE 3:1 3:1 1. 0 0 ' 0.17' SKIMMER 1.5" PVC 2. 2 0 ' CL SKIMMER 1.5" PVC 2. 2 0 ' CLEANOUT ELEV.=29.25 OUTSIDE EDGE OF 4" WIDE STEEL PLATE CL OF 1" X1" STAINLESS STEEL TUBING FOR TRASH RACK (SEE TRASH RACK DETAILS SHEET EC-106) 3/8" X 4" STEEL PLATE (TYPICAL ALL SIDES) STAINLESS STEEL TRASH RACK (SEE DETAILS SHEET EC-106) 24 ° ' 3/8" X 4" STEEL PLATE (TYP. ALL SIDES) 24 ° ' OUTSIDE EDGE OF 4" WIDE STEEL PLATE EC-103 SEDIMENT AND EROSION CONTROL STRUCTURE AND SPILLWAY DETAILS c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 NOTE: RISER STRUCTURE IS TO BE CONSTRUCTED UNDER THE ADVANCE SITE PLAN AND SHOULD BE CONSIDERED EXISTING FOR PURPOSES OF THIS PLAN. DETAILS SHOWN FOR INFORMATIONAL PURPOSES ONLY. EC-104 EROSION AND SEDIMENT CONTROL DETAILS PRIMARY SPILLWAY (CONC. RISER) H Z BAFFLES REINFORCED CONCRETE RISER (SEE SHEET EC-103) PLAN VIEW CROSS-SECTION VIEW SKIMMER DEWATERING DEVICE * AREA OF BASIN WATER SURFACE AT TOP OF PRIMARY SPILLWAY 1.0' FREEBOARD CLEANOUT ELEV. 29.25 DEWATERING ZONE BAFFLE L 5-F T . 1.25' SEDIMENT STORAGE W SKIMMER BASIN SCALE: N.T.S.SB DESIGNED FOR FAIRCLOTH SKIMMER MAINTENANCE: 1.INSPECT SKIMMER SEDIMENT BASIN AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (ONE-HALF INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN SEDIMENT ACCUMULATES TO ONE-HALF THE HEIGHT OF THE FIRST BAFFLE. PULL THE SKIMMER TO ONE SIDE SO THAT THE SEDIMENT UNDERNEATH IT CAN BE EXCAVATED. EXCAVATE THE SEDIMENT FROM THE ENTIRE BASIN, NOT JUST AROUND THE SKIMMER OR THE FIRST CELL. MAKE SURE VEGETATION GROWING IN THE BOTTOM OF THE BASIN DOES NOT HOLD DOWN THE SKIMMER. 2.REPAIR THE BAFFLES IF THEY ARE DAMAGED. RE-ANCHOR THE BAFFLES IF WATER IS FLOWING UNDERNEATH OR AROUND THEM. 3.IF THE SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE BASIN, USUALLY JERKING THE ROPE WILL MAKE THE SKIMMER BOB UP AND DOWN AND DISLODGE THE DEBRIS AND RESTORE FLOW. IF THIS DOES NOT WORK, PULL THE SKIMMER OVER TO THE SIDE OF THE BASIN AND REMOVE THE DEBRIS. ALSO CHECK THE ORIFICE INSIDE THE SKIMMER TO SEE IF IT IS CLOGGED; IF SO, REMOVE THE DEBRIS. 4.IF THE SKIMMER ARM OR BARREL PIPE IS CLOGGED, THE ORIFICE CAN BE REMOVED AND THE OBSTRUCTION CLEARED WITH A PLUMBER'S SNAKE OR BY FLUSHING WITH WATER. BE SURE AND REPLACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER. 5.CHECK THE FABRIC LINED SPILLWAY FOR DAMAGE AND MAKE ANY REQUIRED REPAIRS WITH FABRIC THAT SPANS THE FULL WIDTH OF THE SPILLWAY. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE SKIMMER AND POOL AREAS. 6.FREEZING WEATHER CAN RESULT IN ICE FORMING IN THE BASIN. SOME SPECIAL PRECAUTIONS SHOULD BE TAKEN IN THE WINTER TO PREVENT THE SKIMMER FROM PLUGGING WITH ICE. TWIN 15" RCP INV. 930.45 INTERNAL 4'.0 X 4.4' X 1.0' ANTI-FLOTATION BLOCK TWIN 15" RCP INV. 30.45 5' X 5' X 1.6' CONCRETE ANTI-FLOTATION BLOCK SKIMMER SC H 4 0 P V C 30.94 32.50 TRASH RACK 28.00 3' 4' MAX. NOTES: 1.INSTALL THREE(3) COIR FIBER BAFFLES IN SILT BASINS AND SEDIMENT DAMS AT DRAINAGE OUTLETS WITH A SPACING OF 14 THE BASIN LENGTH. 2.TWO (2) COIR FIBER BAFFLES CAN BE INSTALLED IN SILT BASINS AND DAMS LASS THAN 20 FT. IN LENGTH WITH A SPACING OF 13 THE BASIN LENGTH. 3.TOP HEIGHT OF COIR FIBER BAFFLES SHALL NOT BE BELOW BASE OF SPILLWAY ELEVATION. DRAPE BAFFLE MATERIAL OVER WIRE STRAND AND SECURE WITH PLASTIC TIES AT POSTS AND ON WIRE EVERY 12"9 GAUGE MIN HIGH TENSION WIRE STRAND SHALL BE SECURED TO POST TO SUPPORT BAFFLE MATERIAL BAFFLE MATERIAL SECURE BOTTOM OF BAFFLE TO GROUND WITH 12" STAPLES AT 12" MAXIMUM SPACING VARIABLE DEPTH INSTALL POST TO ANCHOR BAFFLE TO SIDE OF BASIN AND SECURE TO VERTICAL POST STEEL POST - 2'-0" DEPTH 12" 11 GAUGE LANDSCAPE STAPLE BAFFLE MATERIAL BAFFLE MATERIAL SHALL BE SECURED TO THE BOTTOM AND SIDE OF BASIN USING 12" LANDSCAPE STAPLES PORTDAVEN HOME OFFICE WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 119 BROOKSTOWN AVE. SUITE PH1 COIR FIBER BAFFLE ROADWAY STANDARD DRAWING FOR STATE OF NORTH CAROLINA DEPT. OF TRANSPORTATION DIVISION OF HIGHWAYS RALEIGH, N.C. 1-18 16 4 0 . 0 1 12 F T . CLASS 'A' STONE 8 IN. MIN. DEPTH PUB L I C R O A D 50 F T . NOTES 1.PROVIDE TURNING RADIUS SUFFICIENT TO ACCOMMODATE LARGE TRUCKS. 2.LOCATE ENTRANCES TO PROVIDE FOR UTILIZATION BY ALL CONSTRUCTION VEHICLES. 3.MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR DIRECT FLOW OF MUD ONTO STREETS. 4.ANY MATERIAL TRACKED ONTO THE ROADWAY MUST BE CLEANED UP IMMEDIATELY. 5.LOCATE GRAVEL CONSTRUCTION ENTRANCE AT ALL POINTS OF INGRESS AND EGRESS UNTIL SITE IS STABILIZED. PROVIDE FREQUENT CHECKS OF THE DEVICE AND TIMELY MAINTENANCE. 6.NUMBER AND LOCATION OF CONSTRUCTION ENTRANCES TO BE DETERMINED BY THE ENGINEER. 7.USE CLASS 'A' STONE OR OTHER COARSE AGGREGATE APPROVED BY THE ENGINEER. 8.INSTALL CONSTRUCTION ENTRANCE LEAVING PROJECT SITE. NOTE: PLACE GEOTEXTILE FOR DRAINAGE BENEATH STONE GRAVEL CONSTRUCTION ENTRANCE SCALE: N.T.S.CE 8' MAX. WITH WIRE (6' MAX. WITHOUT WIRE) 24" MAX (18" MIN.) 8"4" NOTES USE GEOTEXTILE A MINIMUM OF 36" IN WIDTH AND FASTEN ADEQUATELY TO THE POSTS AND WIRE AS DIRECTED. USE WIRE A MINIMUM OF 32" IN WIDTH AND WITH A MINIMUM OF 5 LINE WIRES WITH 12" VERTICAL SPACING. PROVIDE 5' -0" OF THE SELF-FASTENER ANGLE STEEL TYPE. FOR MECHANICAL SLICING METHOD INSTILATION, GEOTEXTILE SHALL BE A MAXIMUM OF 18" ABOVE GROUND SURFACE TOP AND BOTTOM STRAND SHALL BE 10 GAUGE MIN. GEOTEXTILE COMPACTED FILL MIDDLE AND VERTICAL WIRES SHALL BE 12 12 GAUGE MIN. GEOTEXTILE EXTENSION OF GEOTEXTILE& WIRE INTO TRENCH STEEL POST - 2' DEPTH TEMPORARY SILT FENCE SCALE: N.T.S.SF MAINTENANCE: 1.FILTER BARRIERS SHALL BE INSPECTED BY THE FINANCIALLY RESPONSIBLE PARTY OR HIS AGENT IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REPAIRS NEEDED SHALL BE MADE IMMEDIATELY. 2.SHOULD THE FABRIC DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE END OF THE EXPECTED USABLE LIFE AND THE BARRIER STILL IS NECESSARY, THE FABRIC SHALL BE REPLACED PROMPTLY. 3.SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN DEPOSITS REACH HALF THE HEIGHT OF THE BARRIER. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE IS REMOVED SHALL BE DRESSED TO CONFORM TO THE EXISTING GRADE, PREPARED AND SEEDED. DEWATERING CONCRETE BLOCK DEWATERING DEWATERING DEWATERING WIRE SCREEN SEDIMENT DROP INLET WITH GRATE TEMPORARY SEDIMENT POOL CONSTRUCTION SPECIFICATIONS: 1.LAY ONE BLOCK ON EACH SIDE OF THE STRUCTURE ON ITS SIDE IN THE BOTTOM ROW TO ALLOW POOL DRAINAGE. THE FOUNDATION SHOULD BE EXCAVATED AT LEAST 2 INCHES BELOW THE CREST OF THE STORM DRAIN. PLACE THE BOTTOM ROW OF BLOCKS AGAINST THE EDGE OF THE STORM DRAIN FOR LATERAL SUPPORT AND TO AVOID WASHOUTS WHEN OVERFLOW OCCURS. IF NEEDED, GIVE LATERAL SUPPORT TO SUBSEQUENT ROWS BY PLACING 2X4 WOOD STUDS THROUGH BLOCK OPENINGS. 2.CAREFULLY FIT HARDWARE CLOTH OR COMPARABLE WIRE MESH WITH 1 2 INCH OPENINGS OVER ALL BLOCK OPENINGS TO HOLD GRAVEL IN PLACE. 3.USE CLEAN GRAVEL 3 4 TO 1 2 INCH IN DIAMETER, PLACED 2 INCHES BELOW THE TOP OF THE BLOCK ON A 2:1 SLOPE OR FLATTER AND SMOOTH IT TO AN EVEN GRADE. DOT#57 WASHED STONE IS RECOMMENDED. BLOCK & GRAVEL INLET PROTECTION - DETAIL 6.52 SCALE: N.T.S.IP CW DATA BLOCK SKIMMER PIPE DRAINAGE AREA (ACRES) DISTURBED AREA (ACRES) BASIN VOLUME REQUIRED PROVIDED (CUBIC FT.) CLEANOUT ELEVATION (CUBIC FT.) (FEET) H Ls T Wd (FEET)(FEET)(FEET) BASIN BASIN SURFACE AREA REQUIRED PROVIDED (SQ FT.)(SQ FT.) (FEET) Z ORIFICE DIAMETERDIAMETER SKIMMER Q10 1.5"0.9"5.0' L W (FEET)(FEET) BASIN BASIN SKIMMER ARM LENGTH ANTI-FLOTATION BLOCK LENGTH (FEET) ANTI-FLOTATION BLOCK WIDTH (FEET) ANTI-FLOTATION BLOCK HEIGHT (FEET) 4.4INITIAL5.39 1.12 15.57 5,061 11,116 29.50 0.44 3.25 2.18'NA394234,545 4 1.0 1.5"0.7"5.0'4.4INTERIM2.42 2.42 6.76 2,197 11,116 29.50 0.44 3.25 2.18'NA394234,361 4,545 4 1.0 32.50 32.50 TOP ELEV. 28.00 28.00 BOTTOM ELEV. 31.50 31.50 SPILLWAY CREST ELEV. 2,024 GROUND SURFACE 8 IN MIN. 34 IN MIN. 10 FT MAX. CHAIN LINK FENCE COVERED WITH IMPERMEABLE SHEETING EMBED IMPERMEABLE SHEETING 8 IN MIN. INTO GROUND UV RESISTANT IMPERMEABLE SHEETING ON BOTH SIDES OF FENCE EXTEND IMPERMEABLE SHEETING OR PROVIDE SOIL STABILIZATION MATTING 4 FT MIN. ALONG FLOW SURFACE FOLD SHEETING OVER TOP OF FENCE AND SECURE WITH WIRE TIES 238 IN DIAMETER GALVANIZED STEEL OR ALUMINUM POSTS IN DIAMETER GALVANIZED STEEL OR ALUMINUM POSTS CONSTRUCTION SPECIFICATIONS 1.USE 42 INCH HIGH, 9 GAUGE OR THICKER CHAIN LINK FENCING (238 INCH MAXIMUM OPENING). 2.USE 238 INCH DIAMETER GALVANIZED STEEL POSTS OF 0.095 INCH WALL THICKNESS AND SIX FOOT LENGTH SPACED NO FURTHER THAN 10 FEET APART. THE POSTS DO NOT NEED TO BE SET IN CONCRETE. 3.FASTEN CHAIN LINK FENCE SECURELY TO THE FENCE POSTS WITH WIRE TIES. 4.SECURE 10 MIL OR THICKER UV RESISTANT, IMPERMEABLE SHEETING TO CHAIN LINK FENCE WITH TIES SPACED EVERY 24 INCHES AT TOP, MID SECTION, AND BELOW GROUND SURFACE. 5.EXTEND SHEETING A MINIMUM OF 4 FEET ALONG FLOW SURFACE AND EMBED END A MINIMUM OF 8 INCHES INTO GROUND. SOIL STABILIZATION MATTING MAY BE USED IN LIEU OF IMPERMEABLE SHEETING ALONG FLOW SURFACE. 6.WHEN TWO SECTIONS OF SHEETING ADJOIN EACH OTHER, OVERLAP BY 6 INCHES AND FOLD WITH SEAM FACING DOWNGRADE. MAINTENANCE 1.KEEP FLOW SURFACE ALONG DIVERSION FENCE AND POINT OF DISCHARGE FREE OF EROSION. REMOVE ACCUMULATED SEDIMENT AND DEBRIS. MAINTAIN POSITIVE DRAINAGE. REPLACE IMPERMEABLE SHEETING IF TORN. IF UNDERMINING OCCURS, REINSTALL FENCE. ELEVATION SECTION DIVERSION FENCE DETAIL SCALE: N.T.S.DF 11 ISOMETRIC VIEW PROFILE ALONG CENTERLINE SIDE SLOPE OF TRAP/BASIN 2:1 OR FLATTER 2: 1 O R FL A T T E R COMPACTED EMBANKMENT SLO P E BET W E E N 4:1 A N D 1 0 : 1 TRAP/BASIN BOTTOM TRAP/BASIN BOTTOM 2 2 10 FT MIN. 10 FT MIN. 19 IN MIN. DEPTH OF CLASS I RIPRAP 4 FT MIN. 10 FT MIN. ENTRANCE SECTION 10 FT MIN. EXIT SECTION 0% SLOPE CROSS SECTION 1 1 1 FT MIN. DEPTH 2 2 19 IN MIN. DEPTH OF CLASS I RIPRAP4 FT MIN.NONWOVEN GEOTEXTILE NONWOVEN GEOTEXTILE CONSTRUCTION SPECIFICATIONS 1.PROVIDE NONWOVEN GEOTEXTILE, CONFORMING TO ASTM D-1682 OR ASTM-D-177, UNDER THE BOTTOM AND ALONG SIDES OF ALL RIPRAP. 2.CONSTRUCT INFLOW CHANNEL WITH CLASS B RIPRAP TO A MINIMUM DEPTH OF 19 INCHES (2 x D50) AND A 1 FOOT DEEP FLOW CHANNEL. INFLOW RIPRAP PROTECTION CHANNEL MUST HAVE A TRAPEZOIDAL CROSS SECTION WITH 2:1 OR FLATTER SIDE SLOPES AND A 4 FOOT MINIMUM BOTTOM WIDTH. 3.INSTALL ENTRANCE AND EXIT SECTIONS AS SHOWN ON THE PROFILE. 4.BLEND RIPRAP INTO EXISTING GROUND. MAINTENANCE: MAINTAIN LINE, GRADE, AND CROSS SECTION. REMOVE ACCUMULATED SEDIMENT AND DEBRIS. KEEP POINTS OF INFLOW AND OUTFLOW FREE OF EROSION. RIP-RAP INFLOW PROTECTION SCALE: N.T.S.RRI 1.5"0.6 5.0'4.4FINAL2.26 1.72 5.27 1,712 11,116 29.50 0.44 3.25 2.18'NA394233,103 4,545 4 1.0 32.50 28.00 31.50 #1 WET STOR. ELEV=30.50 NA NA NA c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 EC-105 EROSION AND SEDIMENT CONTROL DETAILS AA 3' CONCRETE WASHOUT B B CONCRETE WASHOUT SIGN DETAIL OR E4UIVALENT WOOD POST 3.5" X 3.5" X8' BLACK LETTERS 6" HEIGHT PLYWOOD 48"X 24" PAINTED WHITE LAG SCREWS 36" 36" TYPE "ABOVE GRADE" W/ STRAW BALES N.T.S. STRAW BALE (TYP) PLAN 10 mil PLASTIC LINING VARIES 10' MIN. WOOD OR METAL STAKES (2 PER BALE) 10 mil PLASTIC LINING STRAW BALE BINDER WIRE NATIVE MATERIAL (OPTIONAL) STAPLES (2 PER BALE) SECTION B-B B B 2" 8" STAPLE DETAIL TYPE "ABOVE GRADE" W/ WOOD PLANKS N.T.S. PLAN 10 mil PLASTIC LINING VARIES 10' MIN. STAKE (TYP) TWO-STACKED 2 X 12 ROUGH WOOD FRAME WOOD FRAME SECURELY FASTENED AROUND ENTIRE PERIMETER WITH 2 STAKES 10 mil PLASTIC LINING SECTION B-B 1.12" DIA. STEEL WIRE TYPE "BELOW GRADE" N.T.S. PLAN10 mil PLASTIC LINING VARIES BERM SANDBAG 10' MIN. SECTION A-A BERM SANDBAG10 mil PLASTIC LINING LATH AND FLAGGING ON 3 SIDES CONCRETE WASHOUTCW NOTES: 1.ACTUAL LAYOUT TO BEDETERMINED IN THE FIELD. 2.A CONCRETE WASHOUT SIGN SHALL BE INSTALLED WITHIN 30' OF THE TEMPORARY CONCRETE WASHOUT FACILITY. 3.MATERIALS USED TO CONSTRUCT TEMPORARY CONCRETE WASHOUT FACILITIESSHALL BE REMOVED FROM THESITE OF THE WORK ANDDISPOSED OF OR RECYCLED. 4.HOLES, DEPRESSIONS OR OTHER GROUND DISTURBANCE CAUSED BY THE REMOVAL OF THE TEMPORARY CONCRETE WASHOUT FACILITIES SHALL BE BACKFILLED, REPAIRED, AND STABILIZED TO PREVENT EROSION. 5.MUST BE LOCATED >50 FT AWAY FROM INLETS/WATERWAYSUNLESS THERE IS NO OTHERPRACTICAL ALTERNATIVE. MAINTENANCE: 1.INSPECT AT LEAST ONCE PER SEVEN CALENDAR DAYS, OR WITHIN A REASONABLE TIME PERIOD (NOT TO EXCEED 48 HOURS) OF A RAINFALL EVENT WHICH CAUSES STORMWATER RUNOFF TO OCCUR ON-SITE. REMOVE AND DISPOSE OF HARDENED CONCRETE AND RETURN THE FACILITY TO A FUNCTIONAL CONDITION. WASHOUT FACILITIES MUST BE CLEANED, OR NEW FACILITIES MUST BE CONSTRUCTED AND READY FOR USE ONCE THE WASHOUT IS 75% FULL. MOUNTABLE BERM SCALE: N.T.S.MB COMPOST SOCK SCALE: N.T.S.CS SPECIAL SILT FENCE SCALE: N.T.S.SSF EROSION CONTROL MATTING SCALE: N.T.S.ECM c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 EC-106 EROSION AND SEDIMENT CONTROL NOTES AND DETAILS NCG01 SELF-INSPECTION, RECORDKEEPING AND REPORTING EFFECTIVE: 04/01/19 PART III SELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION A: SELF-INSPECTION Self-inspections are required during normal business hours in accordance with the table below. When adverse weather or site conditions would cause the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which it is safe to perform the inspection. In addition, when a storm event of equal to or greater than 1.0 inch occurs outside of normal business hours, the self-inspection shall be performed upon the commencement of the next business day. Any time when inspections were delayed shall be noted in the Inspection Record. NOTE: The rain inspection resets the required 7 calendar day inspection requirement. PART III SELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION B: RECORDKEEPING 1.E&SC Plan Documentation The approved E&SC plan as well as any approved deviation shall be kept on the site. The approved E&SC plan must be kept up-to-date throughout the coverage under this permit. The following items pertaining to the E&SC plan shall be kept on site and available for inspection at all times during normal business hours. 2. Additional Documentation to be Kept on Site In addition to the E&SC plan documents above, the following items shall be kept on the site and available for inspectors at all times during normal business hours, unless the Division provides a site-specific exemption based on unique site conditions that make this requirement not practical: (a)This General Permit as well as the Certificate of Coverage, after it is received. (b)Records of inspections made during the previous twelve months. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically-available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard-copy records. PART III SELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1.Occurrences that Must be Reported Permittees shall report the following occurrences: (a)Visible sediment deposition in a stream or wetland. (b)Oil spills if: ·They are 25 gallons or more, ·They are less than 25 gallons but cannot be cleaned up within 24 hours, ·They cause sheen on surface waters (regardless of volume), or ·They are within 100 feet of surface waters (regardless of volume). (c) Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S. 143-215.85. (d)Anticipated bypasses and unanticipated bypasses. (e)Noncompliance with the conditions of this permit that may endanger health or the environment. 2.Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Department's Environmental Emergency Center personnel at (800) 858-0368. 3. Documentation to be Retained for Three Years All data used to complete the e-NOI and all inspection records shall be maintained for a period of three years after project completion and made available upon request. [40 CFR 122.41] PART II, SECTION G, ITEM (4) DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT Sediment basins and traps that receive runoff from drainage areas of one acre or more shall use outlet structures that withdraw water from the surface when these devices need to be drawn down for maintenance or close out unless this is infeasible. The circumstances in which it is not feasible to withdraw water from the surface shall be rare (for example, times with extended cold weather). Non-surface withdrawals from sediment basins shall be allowed only when all of the following criteria have been met: (a)The E&SC plan authority has been provided with documentation of the non-surface withdrawal and the specific time periods or conditions in which it will occur. The non-surface withdrawal shall not commence until the E&SC plan authority has approved these items, (b)The non-surface withdrawal has been reported as an anticipated bypass in accordance with Part III, Section C, Item (2)(c) and (d) of this permit, (c)Dewatering discharges are treated with controls to minimize discharges of pollutants from stormwater that is removed from the sediment basin. Examples of appropriate controls include properly sited, designed and maintained dewatering tanks, weir tanks, and filtration systems, (d)Vegetated, upland areas of the sites or a properly designed stone pad is used to the extent feasible at the outlet of the dewatering treatment devices described in Item (c) above, (e)Velocity dissipation devices such as check dams, sediment traps, and riprap are provided at the discharge points of all dewatering devices, and (f)Sediment removed from the dewatering treatment devices described in Item (c) above is disposed of in a manner that does not cause deposition of sediment into waters of the United States. EXISTING CONDITIONS THE 2.95 ACRE SITE IS LOCATED AT 4400 NORTHCHASE PKWY, NE, WILIMINGON, NC. THE PROPERTY IS UNDEVELOPED AND MOSTLY WOODED, WITH DRAINAGE EASEMENTS ENCUMBERING THE WESTERN AND SOUTHERN PROPERTY LINES. A PRELIMINARY JURISDICTIONAL DETERMINATION HAS BEEN MADE BY THE U.S. ARMY CORPS OF ENGINEERS IDENTIFYING POTENTIAL JURISDICTIONAL WATERS OF THE US WITHIN A SWALE ALONG THE WESTERN BOUNDARY. STANDING WATER HAS BEEN OBSERVED IN THIS LOCATION. THE SITE RUNOFF GENERALLY FLOWS FROM NORTH EAST TO SOUTH WEST AND IS LOCATED IN THE PRINCE GEORGE WATERSHED AND IS PART OF THE CAPE FEAR RIVER BASIN. OFFSITE RUNOFF ENTERS THE SUBJECT PROPERTY AT TWO POINTS. THE FIRST IS THROUGH A SHALLOW SWALE ALONG NORTHCHASE PARKWAY WHICH FLOWS THROUGH AN EXISTING 15" PIPE AND THEN TRAVELS ALONG THE WESTERN PROPERTY BOUNDARY THROUGH ANOTHER UN-MAINTAINED SWALE AND EXITING THE PROPERTY AT THE SOUTHWEST CORNER OF THE PROPERTY. THE SECOND IS FROM THE OUTLET OF AN ADJACENT STORMWATER MANAGEMENT POND, WHICH ENTERS THE SITE AT THE SOUTH EAST CORNER AND FLOWS THROUGH A DRAINAGE EASEMENT AND SWALE ALONG THE SOUTHERN PROPERTY LINE WHERE IT JOINS WITH THE AFOREMENTIONED WESTERN SWALE AND EXITS THE PROPERTY AT THE SOUTH EAST CORNER. THE MAJORITY OF ONSITE RUNOFF IS SPLIT BETWEEN THE TWO SWALES BY A RIDGE AT THE CENTER OF THE SITE AND FLOWS TO THE SAME POINT OF EXIT DESCRIBE ABOVE. A SMALLER AREA OF ONSITE RUNOFF DRAINS TO THE NORTH TO THE SWALE ALONG NORTHCHASE PARKWAY AND JOINS WITH BOTH OFFSITE AND ONSITE RUNOFF THROUGH THE WESTERN SWALE TO THE SAME EXIT POINT. OFFSITE AREAS SIGNIFICANT AMOUNTS OF RUNOFF ENTER THE SITE FROM OFFSITE AREAS, AND FLOW TO A SINGLE POINT OF EXIT AT THE SOUTHWEST CORNER OF THE PROJECT SITE. DIVERTING THIS OFFSITE RUNOFF AWAY FROM OUR SITE IS NOT FEASIBLE. UNDER THIS PLAN, A NEW 15" CULVERT IS BEING PROPOSED WITHIN THE NORTHCHASE RIGHT OF WAY TO CONVEY RUNOFF FROM THE EXISTING ROADSIDE SWALE UNDER THE NEW ENTRANCE TO THE PROJECT SITE. THERE IS ALSO SOME MINOR ENCROACHMENT INTO THE ADJACENT PROPERTY TO THE SOUTH FOR NECESSARY GRADING IMPROVEMENTS TO THE EXISTING SWALE. ALL SUCH GRADING IS CONTAINED WITHIN THE EXISTING DRAINAGE EASEMENT. ULTIMATELY THERE WILL BE ADDITIONAL MINOR IMPROVEMENTS REQUIRED IN THE NORTHCHASE PARKWAY RIGHT OF WAY FOR A DRIVEWAY CONNECTION, WATER AND SEWER CONNECTIONS, AND THE RE-STRIPING OF NORTHCHASE PARKWAY UNDER THE FULL BUILD OUT SITE PACKAGE. SOILS A GEOTECHNICAL STUDY HAS BEEN PERFORMED BY S&ME, INC. AND THE CONTRACTOR SHALL FOLLOW ALL APPLICABLE STANDARDS AND SPECIFICATIONS NOTED IN THE STUDY DATED JULY 26, 2023. SOILS DELINEATION HAS BEEN PROVIDED ON THE EROSION CONTROL SHEETS. Mu, Se, AND St, MURVILLE, SEAGATE AND STALLINGS FINE SAND, RESPECTIVELY. ALL AREAS ARE 0 TO 2 PERCENT SLOPES, WITH HYDROLOGIC SOIL GROUPS A/D FOR MURVILLE AND STALLINGS AND GROUP B FOR SEAGATE. SOIL BORINGS REVEALED SOILS LIMITATIONS FOR BUILDING CONSTRUCTION, WHICH REQUIRES MITIGATION. A SURCHARGE METHOD WAS DECIDED UPON, TO LOAD AND SUFFICIENTLY COMPACT EXISTING SOILS OVER A PERIOD OF TIME. THE GRADING, SEDIMENT CONTROLS AND PLACEMENT OF SURCHARGE ARE THE PURPOSE OF THIS PLAN. CRITICAL AREAS A PRELIMINARY JURISDICTIONAL DETERMINATION HAS BEEN MADE BY THE U.S. ARMY CORPS OF ENGINEERS IDENTIFYING POTENTIAL JURISDICTIONAL WATERS OF THE US WITHIN A SWALE ALONG THE WESTERN BOUNDARY. THERE ARE NO OTHER FLOOD ZONES, OR WETLANDS, IDENTIFIED WITHIN THIS SITE. EROSION CONTROL MEASURES THE SEDIMENT CONTROL CONCEPT FOR THIS SITE PROPOSES STAGING THE DEMO, GRADING AND CONSTRUCTION OF SEDIMENT CONTROLS, TO MINIMIZE THE AMOUNT OF AREA BEING DISTURBED AT ANY ONE TIME. UNDER THE INITIAL STAGE, INSTALLATION OF A SEDIMENT BASIN WILL OCCUR, WHICH WILL TEMPORARILY INTERCEPT BOTH ONSITE AND OFFSITE DRAINAGE. ASSOCIATED PERIMETER CONTROLS AND SITE CLEARING WILL BE DONE ONLY AS NECESSARY TO INSTALL THE BASIN AND MAKE NECESSARY IMPROVEMENTS TO THE SWALES ALONG THE WESTERN AND SOUTHERN BOUNDARIES. BOTH ARE BEING TEMPORARILY INTERCEPTED BY THE SEDIMENT BASIN WHILE GRADING IMPROVEMENTS ARE MADE. THE WESTERN SWALE WILL BE UTILIZED AS PART OF THE VOLUME OF THE SEDIMENT BASIN FOR THE DURATION OF THE PROJECT, WHILE THE SOUTHERN SWALE WILL BE STABILIZED AS QUICKLY AS POSSIBLE. ONCE THIS SWALE HAS BEEN STABILIZED, THE BASIN EMBANKMENT WILL BE RE-GRADED TO RE-DIRECT THAT DRAINAGE, WHICH INCLUDED RUNOFF FROM AN OFFSITE POND, AWAY FROM THE BASIN AND BACK TO ITS ORIGINAL COURSE. AT THIS POINT ALL DISTURBED ONSITE AREAS DRAINING TO THE SOUTHERN SWALE CAN EITHER BE HANDLED WITH PERIMETER CONTROLS. THE INTERIM STAGE WILL INCLUDE ADDITIONAL CLEARING, MASS GRADING OF THE SITE, PLACEMENT OF ADDITIONAL PERIMETER CONTROLS AND PLACEMENT OF SURCHARGE SOILS WITHIN THE BUILDING PAD. THE FINAL STAGE WILL INCLUDE THE REMOVAL OF SURCHARGE SOIL FROM THE SITE AND COMPLETION OF MASS GRADING IN ADVANCE OF THE COMMENCEMENT OF THE FULL BUILD OUT SITE PLAN. THE SEDIMENT BASIN WILL REMAIN IN PLACE TO BE UTILIZED FOR THE ULTIMATE CONSTRUCTION OF THE BUILDING, AND INSTALLATION OF PAVING AND SITE UTILITIES. SEE SHEET EC1.00 THROUGH EC1.07 FOR EROSION CONTROL CONSTRUCTION AND MAINTENANCE DETAILS. PROJECT DESCRIPTION THE PROJECT IS LOCATED AT 4400 NORTHCHASE PKWY. NE, WILMINGTON, NC. THIS PROJECT ULTIMATELY PROPOSES THE CONSTRUCTION OF A NEW NORTHCHASE PUBLIC LIBRARY, A NEW ENTRANCE FROM NORTHCHASE PARKWAY, INTERIOR DRIVEWAYS, PARKING AREAS, OUTDOOR EDUCATION AND SEATING AREAS, A BIKE PATH, UTILITY EXTENSIONS LIMITED TO WATER, SANITARY, AND STORM, AS WELL AS RELATED SERVICE LATERALS, CONDUITS FOR FRANCHISE UTILITIES, SIDEWALKS, STRIPING & SIGNAGE, STORMWATER WETLAND,AND NECESSARY REPARATIONS TO EXISTING STREETS. THIS PLAN PROPOSES THE MASS GRADING OF THE PROJECT SITE IN ADVANCE OF FULL BUILD OUT FOR THE PURPOSES OF SURCHARGE SOIL PLACEMENT TO MITIGATE POOR STRUCTURAL SOILS BENEATH THE FUTURE BUILDING FOUNDATION, AS WELL AS EARLY PLACEMENT OF NECESSARY SEDIMENT CONTROLS AND A SEDIMENT BASIN WHICH WILL LATER BE CONVERTED TO A STORMWATER WETLAND UNDER THE ULTIMATE BUILDOUT. LIMITS OF DISTURBANCE 3.15 ACRES (ROUNDS TO 4 ACRES FOR FEES) EROSION AND SEDIMENT CONTROL NARRATIVE STAINLESS STEEL TAKE-UP CLAMP WS-30 WATERSTOP GASKET (TYP.) WS-30 WATERSTOP GASKET WITH TAKE-UP CLAMP WS-30 WATERSTOP GASKET DETAIL NOT TO SCALE 1" DIP CENTER GASKET IN WALL RUBBER GASKET IN JOINT FLOW TYPICAL ARTICULATION JOINT CONCRETE SUPPORT BLOCKS E E RCP OUTLET PIPE O-RING GASKETED REINFORCED CONCRETE PIPE 3 4" PRE-MOLDED JOINT FILLER CONCRETE PIPE CRADLE DETAIL NOT TO SCALE NOTE: PIPE CRADLE JOINT SHALL BE CONSTRUCTED AT EACH JOINT LOCATION IN THE PIPE EACH JOINT TO BE WRAPPED IN NON-WOVEN GEOTEXTILE TRENCH TO BE USED AS FORM FOR CONCRETE CRADLE 0 9"+ (1 2"X O,D,) (MIN.) 9" (MIN.) 8" (MIN.) O.D.+ 16" (MIN.) SUB-GRADE TO BE NATIVE MATERIAL OR COMPACTED TO 100% MAX. DRY DENSITY IN FILL CONDITIONS 3000 PSI (MIN.) CONCRETE CRADLE ALLOW MIN. OF 24 HR CURE TIME (48 HR. PREFERRED) PRIOR TO BACKFILLING 2:1 SLOPE (IF NEEDED FOR DEPTH OF TRENCH) SECTION E-E NOT TO SCALE STAINLESS STEEL BOLTS (2 PER WALL) 4"X3/8" STAINLESS STEEL PLATES 1"X1" STAINLESS STEEL TUBING 2'-2"2'-2" 2' - 4 " 2'- 4 " 4" 4" 1' - 2 " 3'-3" 2' - 3 " 4"4" 6" (TYP.) NOT TO SCALE TRASH RACK DETAILS 9" (T Y P . ) 10" (TYP.) 2'-4 "2'-4 "4"4" 9" RISER ~ ~ TOP VIEW FRONT ELEVATION TRASH RACK WELDING DETAIL 1" x 1" TUBING MITER CORNERS 4" MIN. *ALL STEEL SHALL BE ASTM A-36 (OR A-500 FOR TUBING) FULLY GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A-123 NOT TO SCALE WELD (TYP.) WELD (TYP.) 1/2 " X 6" GALVANIZED STEEL BOLT (TYP.) ASTM A-307 GALVANIZED NUT AND WASHER 3/8 " X 4" STEEL PLATE 1" X 1" TUBING CENTERED ON STEEL PLATE 2" INSIDE FACE OF RISER =30.94RISER CREST EL. =32.45TOP WALL EL. 9" 6" 1 2 1 2 1. 5 1 ' 3/8 " X 4" STEEL PLATE (BOTH SIDES) 3/8 " X 4" STEEL PLATE (BOTH SIDES) 1 2 1 2 1"X1" STAINLESS STEEL TUBING 2" =30.94RISER CREST EL. =32.45TOP WALL EL. 6" 9" RISER ~ ~3/8 " X 4" STEEL PLATE 1-2 " (TYP.) 1 4 3/8 " X 4" STEEL PLATE 4" (T Y P ) 1 4 (T Y P . ) PROPOSED HINGE(S) FOR 3'-3" X 2'-3 " ACCESS 1 2 PROPOSED HINGE(S) FOR 3'-3" X 2'-3 " ACCESS PROPOSED LOCK CONNECTION SIDE VIEW PROPOSED LOCK CONNECTION 9" 24° 1 2 10" (TYP.) 1 2 c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 EC-107 EROSION AND SEDIMENT CONTROL NOTES NCG01 GROUND STABILIZATION AND MATERIALS HANDLING EFFECTIVE: 04/01/19 GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH THE NCG01 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCG01 Construction General Permit (Sections E and F, respectively). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below: POLYACRYLAMIDES (PAMS) AND FLOCCULANTS 1.Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2.Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3.Apply flocculants at the concentrations specified in the NC DWR List of Approved PAMS/Flocculants and in accordance with the manufacturer's instructions. 4.Provide ponding area for containment of treated Stormwater before discharging offsite. 5.Store flocculants in leak-proof containers that are kept under storm-resistant cover or surrounded by secondary containment structures. HAZARDOUS AND TOXIC WASTE 1.Create designated hazardous waste collection areas on-site. 2.Place hazardous waste containers under cover or in secondary containment. 3.Do not store hazardous chemicals, drums or bagged materials directly on the ground. EQUIPMENT AND VEHICLE MAINTENANCE 1.Maintain vehicles and equipment to prevent discharge of fluids. 2.Provide drip pans under any stored equipment. 3.Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4.Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible). 5.Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6.Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1.Never bury or burn waste. Place litter and debris in approved waste containers. 2.Provide a sufficient number and size of waste containers (e.g dumpster, trash receptacle) on site to contain construction and domestic wastes. 3.Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 4.Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5.Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers. 6.Anchor all lightweight items in waste containers during times of high winds. 7.Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow. 8.Dispose waste off-site at an approved disposal facility. 9.On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1.Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2.Locate paint washouts at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3.Contain liquid wastes in a controlled area. 4.Containment must be labeled, sized and placed appropriately for the needs of site. 5.Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1.Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2.Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas. 3.Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit. HERBICIDES, PESTICIDES AND RODENTICIDES 1.Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2.Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning. 3.Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4.Do not stockpile these materials onsite. CONCRETE WASHOUTS 1.Do not discharge concrete or cement slurry from the site. 2.Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility. 3.Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence. 4.Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail. 5.Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6.Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive spills or overflow. 7.Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout. Additional controls may be required by the approving authority. 8.Install at least one sign directing concrete trucks to the washout within the project limits. Post signage on the washout itself to identify this location. 9.Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp, sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary products, follow manufacturer's instructions. 10.At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance caused by removal of washout. EARTHEN STOCKPILE MANAGEMENT 1.Show stockpile locations on plans. Locate earthen-material stockpile areas at least 50 feet away from storm drain inlets, sediment basins, perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available. 2.Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3.Provide stable stone access point when feasible. 4.Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs. SECTION E: GROUND STABILIZATION Required Ground Stabilization Timeframes Note: After the permanent cessation of construction activities, any areas with temporary ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last land disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved. Site Area Description Timeframe variations -7 days for perimeter dikes, swales, ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed unless there is zero slope Stabilize within this many calendar days after ceasing land disturbance 7 7 7 14 None None (a)Perimeter dikes, swales, ditches, and perimeter slopes (b)High Quality Water (HQW) Zones (c)Slopes steeper than 3:1 If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed (d)Slopes 3:1 to 4:1 (e)Areas with slopes flatter than 4:1 14 -7 days for slopes greater than 50' in length and with slopes steeper than 4:1 -7 days for perimeter dikes, swales, ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed SEQUENCE OF CONSTRUCTION: NOTE: C/E$RIN* *RU%%IN* $N' 'E0O/ITION S+$// %E 'ONE IN ST$*ES $CCOR'IN* TO T+IS SEQUENCE OF CONSTRUCTION $N' 'E0O/ITION NOTES ON S+EET T C/E$RIN* $N' *RU%%IN* S+$// %E 3+$SE' TO T+E E;TENT 3R$CTIC$/ TO 0INI0I=E T+E $0OUNT OF $RE$ 'ISTUR%E' $T $N< 3OINT IN TI0E INITI$/ ST$*E: SITE 3RE3$R$TION $N' 'E0O/ITION S+EET EC  :EE.S CONTR$CTOR TO O%T$IN *R$'IN* 3ER0IT $N' CERTIFIC$TE OF CO9ER$*E FOR T+E NC* CONSTRUCTION STOR0:$TER 3ER0IT T+E CERTIFIC$TE OF CO9ER$*E S+$// %E 3OSTE' ONSITE 3RIOR TO /$N''ISTUR%IN* $CTI9IT<  :EE.S  CONT$CT NC'EQ INS3ECTOR $ 0INI0U0 OF T:O :EE.S 3RIOR TO T+E ST$RT OF CONSTRUCTION TO SC+E'U/E $ 3RE CONSTRUCTION 0EETIN* T+E CONTR$CTOR IS TO SU%0IT $ SC+E'U/E OF :OR. $CTI9ITIES TO T+E NE: +$NO9ER COUNT< 'E3$RT0ENT OF 3U%/IC :OR.S 3RIOR TO INITI$TION OF $N< *R$'IN* $CTI9ITIES  '$<S ST$.E INITI$/ /I0IT OF 'ISTUR%$NCE $N' INST$// OR RE3$IR E;ISTIN* ST$%I/I=E' CONSTRUCTION ENTR$NCE 0OUNT$%/E %ER0S SI/T FENCE S3ECI$/ SI/T FENCE $N' CO03OST SOC.S $T /OC$TION S+O:N ON S+EET EC INST$// OR RE3$IR ROC. 3I3E IN/ET 3ROTECTION $T U3STRE$0 EN' OF E;ISTIN* 3I3ES :+ERE S+O:N 0$.E SURE $// NECESS$R< SE'I0ENT CONTRO/S $RE IN 3/$CE 3RIOR TO C/E$RIN* OR *R$'IN*  :EE.S C/E$R $N' *RU% FOR INITI$/ ST$*E SITE CONSTRUCTION C/E$R TREES $N' OT+ER 9E*ET$TION $N' STRI3 $N' *RU% T+E SITE OF OR*$NICS $N' TO3SOI/ $N' $N< OT+ER 'E/ETERIOUS 0$TERI$/S FOR $ /$TER$/ 'IST$NCE OF $T /E$ST  FEET %E<ON' T+E /I0ITS OF NE: CONSTRUCTION :IT+IN T+E INITI$/ /O' $S S+O:N ON S+EET EC $N' $CCOR'IN* TO 'E0O/ITION NOTES ON S+EET T NOTE: 0$INT$IN E;ISTIN* S.I00ER %$SIN $S S+O:N ON S+EETS EC $N' 'ET$I/ S+EETS EC $N' EC  '$<3ROCEE' TO INTERI0 ST$*E :IT+ $33RO9$/ OF INS3ECTOR NOTE: $S SITE IS %ROU*+T TO *R$'E CONTR$CTOR IS TO SEE' $N' ST$%I/I=E SITE $S REQUIRE' INTERI0 ST$*E: S+EET EC  :EE. ST$.E INTERI0 /I0IT OF 'ISTUR%$NCE $N' INST$// $''ITION$/ 3ERI0ETER CONTRO/S TO INC/U'E SI/T FENCES3ECI$/ SI/T FENCE $T /OC$TION S+O:N ON S+EET EC  :EE.C/E$R TREES $N' OT+ER 9E*ET$TION $N' STRI3 $N' *RU% T+E SITE OF OR*$NICS $N' TO3SOI/ $N' $N< OT+ER 'E/ETERIOUS 0$TERI$/S FOR $ /$TER$/ 'IST$NCE OF $T /E$ST  FEET %E<ON' T+E /I0ITS OF NE: CONSTRUCTION :IT+IN T+E INTERI0 /O' $S S+O:N ON S+EET EC $N' $CCOR'IN* TO 'E0O/ITION NOTES ON S+EET T  '$<S %RIN* SITE TO ROU*+ *R$'E E/E9$TIONS :IT+IN T+E INTERI0 /I0IT OF 'ISTUR%$NCE $N' %E*IN %UI/'IN* FOUN'$TION :OR.  :EE.S INST$// :$TER $N' SE:ER 0$INS $N' STOR0 'R$INS  :EE.S INST$// RO$':$< %$SE 3$9IN* CUR% $N' *UTTER FOR T+E 'RI9E:$<S $N' 3$R.IN* $RE$S $N' *R$SS 3$9E FIRE /$NE  0ONT+S CO03/ETE CONSTRUCTION OF %UI/'IN* $N' SER9ICE CONNECTIONS FOR :$TER SE:ER $N' STOR0 'R$IN ROOF /E$'ERS $S :E// $S OT+ER UN'ER*ROUN' UTI/IT< E;TENSIONS $N' CONNECTIONS NOTE: NO 0$-OR *R$'IN* $CTI9ITIES OR %$SIN CONSTRUCTION $RE TO T$.E 3/$CE 'URIN* :ET :E$T+ER OR 3ERIO'S OF3RE'ICTE' :ET :E$T+ER IE +URRIC$NES NOTIF< NC'EQ /QS INS3ECTOR :+EN 3RO-ECT IS RE$'< FOR $ C/OSE OUT INS3ECTION FI/E FOR N3'ES NC*/ ENOTICE OF TER0IN$TION :+EN FIN$/ C/OSE OUT INS3ECTION RE3ORT IS RECEI9E' FRO0 NC'EQ /QS SE'I0ENT %$SIN $N' TR$3 E0%$N.0ENTS S+$// %E 3RO9I'E' :IT+ $'EQU$TE *ROUN'CO9ER I00E'I$TE/< U3ON CONSTRUCTION INS3ECT $N' C/E$NOUT S: S<STE0 %EFORE %RIN*IN* ON/INE SITE 0UST %E STOR0 RE$'< %EFORE $N< E;TEN'E' %RE$.S IN CONSTRUCTION $CTI9ITIES INC/U'IN* :EE.EN'S >$ NC$C %  $  @ CONTR$CTOR S+$// O%T$IN $33RO9$/ FRO0 NC'EQ INS3ECTOR 3RIOR TO $N< OFFSITE %ORRO: OR :$STE $CTI9ITIES $N< %ORRO: OR :$STE 0UST CO0E FRO0 OR *O TO $ 3ER0ITTE' SITE $N' OR F$CI/IT< :$STE $N' OR FI// SITE 3ER0IT NU0%ER:BBBBBBBBBBBBBBBBBBBBBBBBB>$ NC$C % @  '$<3ER0$NENT/< ST$%I/I=E $// 'ISTUR%E' $RE$S FIN$/ ST$*E: S+EET EC  :EE.ST$.E /I0IT OF 'ISTUR%$NCE FOR FIN$/ CON'ITIONS $N' INST$// $''ITION$/ SI/T FENCE $N' S3ECI$/ SI/T FENCE  :EE.S $S CONSTRUCTION NE$RS CO03/ETION INST$// SURF$CE 3$9IN* 3ER0E$%/E 3$9ERS FINE *R$'E T+E SITE INTERIOR INST$// SI'E:$/.S FENCES $0ENITIES SI*+T FURNIS+IN*S SI*N$*E /I*+TIN* $N' /$N'SC$3IN* $N' ST$%I/I=E $// 'ISTUR%E' $RE$S :IT+ TO3SOI/ SEE' 0U/C+  :EE.S RECONSTRUCT E0%$N.0ENT $S S+O:N ON S+EET EC TO ITS 3ER0$NENT /OC$TION FOR 3ER0$NENT S:0 :ET/$N'S STRUCTUR$/ E0%$N.0ENT FI// S+$// %E 3/$CE' $CCOR'IN* TO T+E RECO00EN'$TIONS IN T+E *EOTEC+NIC$/ RE3ORT %< S 0E INC '$TE' -U/<   :+IC+ INC/U'ES T+E FO//O:IN*: USCS C/$SSIFIC$TION OF S0 SC S3 S: OR SO0E CO0%IN$TION OF T+ESE CONT$IN /ESS T+$N  3ERCENT OR*$NICS %E FREE OF TR$S+ OR OT+ER 'E/ETERIOUS 0$TERI$/S +$9E $ 0$;I0U0 3$RTIC/E SI=E OF  INC+ES OR /ESS +$9E $ 0INI0U0 ST$N'$R' 3ROCTOR 0$;I0U0 'R< 'ENSIT< OF  3OUN'S 3ER CU%IC FOOT 3/$CE E0%$N.0ENT FI// IN  /OOSE /IFTS $N' CO03$CT TO $T /E$ST  3ERCENT OF T+E ST$N'$R' 3ROCTOR 0$;I0U0 'R< 'ENSIT< 0'' $ST0 '  T+E TO3  INC+ES S+OU/' %E CO03$CTE' TO $T /E$ST  OF T+E 0$TERI$/S ST$N'$R' 3ROCTOR 0'' :IT+ 0OISTURE CONTENT OF STRUCTUR$/ FI// TO %E 0$INT$INE' $T   OF O3TI0U0 0OISTURE 'URIN* CO03$CTION RES+$3E %$SIN 9O/U0E $S S+O:N ON S+EET EC  '$<S RE3$IR $S NECESS$R< T+E STOR0 STRUCTURES TO 3ER0$NENT/< RE0$IN T+E STOR0 S<STE0 S+$// %E INS3ECTE' $N' C/E$NE' $S NECESS$R< TO ENSURE RESI'U$/ SE'I0ENT 'OES NOT RE0$IN :IT+ 3ER0ISSION OF INS3ECTOR $// IN/ET 3ROTECTION $N' SE'I0ENT CONTRO/S 0$< %E RE0O9E'  '$<S :IT+ 3ER0ISSION OF INS3ECTOR 0O'IF< T+E RISER %$C.FI// $N'OR CON9ERT S.I00ER %$SIN  TO $ 3ER0$NENT STOR0:$TER 0$N$*E0ENT F$CI/IT< 3ER T+E STOR0:$TER 0$N$*E0ENT 3/$NS S+EETS C T+RU C RE0O9E S.I00ER %$FF/ES $N' INF/O: 3ROTECTION  '$<S :IT+ 3ER0ISSION OF INS3ECTOR RE0O9E $// TE03OR$R< EROSION $N' SE'I0ENT CONTRO/ 'E9ICES RE3$IR E;ISTIN* SI'E:$/. CUR% $N' *UTTER $N' 3$9IN* $S REQUIRE' $FTER RE0O9$/ OF SE'I0ENT CONTRO/ 0E$SURES ST$%I/I=E $// $RE$S 'ISTUR%E' 'URIN* RE0O9$/ OF SE'I0ENT CONTRO/ 'E9ICES :IT+ TO3SOI/ SEE' 0U/C+ NOTE: CONTR$CTOR TO O%T$IN SOI/ TEST FOR 3RO3ER FERTI/I=$TION $33/IC$TION R$TES  '$<S CONT$CT NC'EQ INS3ECTOR FOR FIN$/ INS3ECTION $N' $33RO9$/ OF SITE NOTE: SEE NC'EQ EROSION $N' SE'I0ENT CONTRO/ 3/$NNIN* $N' 'ESI*N 0$NU$/ C+$3TER  FOR SITE 3RE3$R$TION 'ET$I/S $N' S3ECIFIC$TIONS NOTE: SEE S+EETS EC T+RU EC FOR SE'I0ENT CONTRO/ NOTES $N' 'ET$I/S c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER 514.18349.00 08/07/2024 NORTHCHASE BRANCH LIBRARY ISSUE FOR ISSUE DATE NO.REASON DATE TRC FINAL APPROVAL JD CD GH w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little B 1 2 3 4 5 6 7 A C D E F 4400 NORTHCHASE PKWY NE WILMINGTON, NC 28405 HOME OFFICE 119 BROOKSTOWN AVE., SUITE PH1 WINSTON-SALEM, NC 27101 336.744.1636 www.davenportworld.com NCBELS FIRM LICENSE NO. C-2522 X X X X 11 5 1 5 " R C P C L I V 1 5 " R C P C L I V 18" RC P C L I V FDC FH-26" W 8" DIP W (FIRE) 6" D I P W 4 " D I P W 6" P V C S E W E R 6" P V C S E W E R 6" PVC SEWER 15" R C P C L I V 15" RCP X X X X X X X X X X X X X X X X X X X X X X X X X X X CL IV 8 15" RCP 2 " D I P W ( D O M ) 8 " D I P W ( F I R E ) 6" P V C S E W E R 6 " P V C S E W E R DO N O T E N T E R 8" D I P W ( F I R E ) 8" P V C S D PVC S D 8 " 8 " P V C S D 8" PVC S D 12" PVC SD 8" PVC SD 8" 8" CL lll HDPE24" 2" D I P W ( D O M ) (FIR E ) 2" D I P W ( D O M ) FH-1 GV R P D A R P 8" D I P W ( F I R E ) 6" P V C S E W E R CL Il l 17 20 20 18 REF. FE C FE C FEC FE C FE C FEC NORTH C H A S E P A R K W A Y N E PUBLIC R / W V A R I E S T 4" PVC STUBOUT X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 4" PVC STUBOUT S SSMH RIM 34.85' (IN) 6" PVC IE 28.85' (IN) 8" PVC IE 27.49' (IN) 6" PVC IE 23.66' (IN) 8" PVC IE 22.83' (OUT) 8" PVC IE 22.77'S WVWV W W W W W W W W W W W W W W W W W W W W W W W W W W S TRANS PAD W W W V WV W V WV GVGV WV FFE=35. 5 0 1 STOR Y L I B R A R Y B U I L D I N G TYP. TYP. TYP. TYP. TYP.TYP. TYP. TYP. TYP. TYP. TYP. 4 2 56 6 F1 1 2 1 1 1 2 7 8 8 10 10 10 10 10 10 10 11 12 12 12 12 13 13 13 13 13 13 13 13 13 13 13 F1 F1 F2 F2 F2 F3 F3 F4 F4 F5 F4 F9 F9 F10 F12 F12 F13 13 F10 F2 10 13 8 9 9 13 13 13 13 13 13 8 F8 F11 F14 8 8 TYP. F10 F12 F12 F11 F11 COVERED PAVILION, SEE ARCH 3 2 2 13 13 TYP. F7 TYP. F7 F6 TYP. F5 F14 TYP. F3 10 10 10 13 TYP. F8 13 8 12 13 13 12 10 12 12 F2 F2 F2 F2 F2 F2 F9 TYP. F4 10 CAUTION!!! THE LOCATIONS AND ELEVATIONS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THIS DRAWING ARE ONLY APPROXIMATE. NO GUARANTEE IS EITHER EXPRESS OR IMPLIED AS TO THE COMPLETENESS OF ACCURACY THEREOF. THE CONTRACTOR SHALL BE EXCLUSIVELY RESPONSIBLE FOR DETERMINING THE EXACT UTILITY LOCATIONS AND ELEVATIONS PRIOR TO THE START OF CONSTRUCTION. 1" = 0 GRAPHIC SCALE 20'-0" 20 10 20 40 80 L100 SITE MATERIALS PLAN 1 LIMITS OF CONSTRUCTION (2.96 ac.) 2 CONCRETE SIDEWALK - SEE CIVIL 3 HEAVY DUTY CONCRETE SIDEWALK - SEE CIVIL 4 CONCRETE MULTI-USE TRAIL - SEE CIVIL 5 PAVERS - HEAVY DUTY VEHICULAR, UNILOCK ECO-PRIORA PAVER, HERRINGBONE PATTERN WITH SOLDIER COURSE EDGE 6 PERMEABLE PAVERS - LIGHT DUTY PEDESTRIAN, UNILOCK ECO-PRIORA PAVER, HERRINGBONE PATTERN WITH SOLDIER COURSE EDGE - SEE DETAIL 1/L300 7 FIRE LANE, GRASS PAVE - SEE CIVIL 8 RIVER ROCK, 2-4" STONES - SEE DETAIL 3/L300 9 RIVER ROCK, 6-8" STONES - SEE DETAIL 3/L300 10 STEEL BED EDGING - SEE DETAIL 4/L300 11 PEDESTRIAN BRIDGE - BY OTHERS 12 SOD - SEE PLANTING PLANS 13 SHRUB AND PERENNIAL PLANTING - SEE PLANTING PLANS F1 POLE LIGHT, VEHICULAR - SEE ELECTRICAL FOR PRODUCT AND MOUNTING DETAIL F2 POLE LIGHT, PEDESTRIAN - SEE ELECTRICAL FOR PRODUCT AND MOUNTING DETAIL F3 BENCH - VESTRE 5506h COAST SEAT WITH OWNERLESS OCEAN PLASTIC, SURFACE MOUNTED F4 CAFE TABLE AND CHAIRS - VESTRE 3713 AND 3731 BERLIN TABLE AND CHAIRS ANCHORING WITH BASE PLATE, RAL 5021 WATER BLUE, STANDARD WOOD F5 ADIRONDACK CHAIR - ANOVA PLANK ADIRONDACK CHAIR HDPE (PLK60R), DRIFTWOOD GRAY - WOODGRAIN F6 PICNIC TABLE & BENCHES -VESTRE 753 APRIL PICNIC TABLE L1500, ADA MODEL WITH BACKREST 1 SIDE, RAL 5020 OCEAN BLUE, STANDARD WOOD F7 PICNIC TABLE & BENCHES -VESTRE 751 APRIL PICNIC TABLE L1500, ADA MODEL WITHOUT BACKRESTS, RAL 5020 OCEAN BLUE, STANDARD WOOD F8 BIKE RACK - VESTRE 686C VROOM BICYCLE RACK SMALL, CASTING IN THE GROUND, RAL 5021 WATER BLUE - SEE DETAIL 2/L300 F9 TRASH & RECYCLING RECEPTACLE - VESTRE 642 VROOM LITTER BIN 80L, HOT-DIP GALVANIZED AND POWDERCOATED STEEL, RAL 5020 OCEAN BLUE - PROVIDED BY NHC F10 BOULDERS - SEE DETAIL 6/L300 F11 CONCRETE BOLLARDS - SEE CIVIL F12 WAYFINDING & EDUCATIONAL SIGNAGE F13 ENTRY MONUMENT SIGN - SEE ELECTRICAL FOR POWER F14 ADD ALTERNATE: CUSTOM TIERED TIMBER BENCH - SEE DETAIL 5/L300 MATERIALS LEGEND: 514.18349.00 08.07.2024 NORTHCHASE BRANCH LIBRARY NO.REASON DATE TRC FINAL APPROVAL Jerry Guerrier, AIA Charlie Hagen-Cazés, AIA R. Florence, PLA, M. Sweitzer 2024 4400 Northchase Parkway NE Wilmington NC 28405 c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER ISSUE FOR ISSUE DATE PREPARED FROM INFORMATION PROVIDED BY THE CONTRACTOR CONSTRUCTING THE PROJECT. DESIGNER DOES NOT WARRANT THE INFORMATION HEREIN TO BE COMPLETE, ACCURATE, OR ALL ENCOMPASSING. RECORD DRAWINGS w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little LAYOUT NOTES A.ALL PAVING CUTS SHALL BE MADE BY SAW CUTS. B.EXISTING ELEVATIONS SHALL BE FIELD VERIFIED AND MATCHED. C.CONTRACTOR TO COORDINATE ANY CHANGES IN FIELD CONDITIONS THAT MAY REVISE THE DESIGN WITH DESIGNER OF RECORD PRIOR TO PROCEEDING. D.ALL DIMENSIONS ARE TO FACE OF CURB OR TO FINISHED FACE OF BUILDING UNLESS NOTED OTHERWISE. E.ALL WORK WITHIN THE RIGHT OF WAY OF ALL ROADS AND HIGHWAYS SHALL BE IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE APPROPRIATE STATE AND/OR LOCAL JURISDICTION. CONTRACTOR SHALL SECURE ALL NECESSARY DRIVEWAY AND ENCROACHMENT PERMITS PRIOR TO CONSTRUCTION. IF NECESSARY, CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL DURING CONSTRUCTION WITHIN THE RIGHT OF WAY, PER WORK AREA TRAFFIC CONTROL HANDBOOK (W.A.T.C.H.) STANDARDS. F.A MINIMUM OF 18" IS TO BE MAINTAINED BETWEEN ALL PAVED SURFACES AND TOPS OF FOOTINGS. G. CONTRACTOR TO INSTALL TEMPORARY SEEDING IN ALL DISTURBED AREAS NOT COVERED BY PAVEMENT UPON COMPLETION OF CONSTRUCTION. CONTRACTOR TO INSTALL PERMANENT SEEDING DURING APPROPRIATE SEEDING SEASON. H.BENCHES AND PICNIC TABLES TO BE SURFACE MOUNTED PER MANUFACTURING INSTRUCTIONS. I.ALL SITE FURNITURE TO BE OWNER PROVIDED, GENERAL CONTRACTOR INSTALLED J.CONTRACTOR TO LOCATE LIGHTS IN THE FIELD AND SUBMIT PHOTOGRAPHS OF FLAGGED LOCATIONS TO LANDSCAPE ARCHITECT APPROVAL PRIOR TO DUKE ENERGY INSTALLATION TYP. X X X X 11 5 1 5 " R C P C L I V 1 5 " R C P C L I V 18" RC P C L I V FDC FH-26" W 8" DIP W (FIRE) 6" D I P W 4 " D I P W 6" P V C S E W E R 6" P V C S E W E R 6" PVC SEWER 15" R C P C L I V 15" RCP X X X X X X X X X X X X X X X X X X X X X X X X X X X CL IV 8 15" RCP 2 " D I P W ( D O M ) 8 " D I P W ( F I R E ) 6" P V C S E W E R 6 " P V C S E W E R DO N O T E N T E R 8" D I P W ( F I R E ) 8" P V C S D PVC S D 8 " 8 " P V C S D 8" PVC S D 12" PVC SD 8" PVC SD 8" 8" CL lll HDPE24" 2" D I P W ( D O M ) (FIR E ) 2" D I P W ( D O M ) FH-1 GV R P D A R P 8" D I P W ( F I R E ) 6" P V C S E W E R CL Il l 17 20 20 18 REF. FE C FE C FEC FE C FE C FEC NORTH C H A S E P A R K W A Y N E PUBLIC R / W V A R I E S T 4" PVC STUBOUT X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 4" PVC STUBOUT S SSMH RIM 34.85' (IN) 6" PVC IE 28.85' (IN) 8" PVC IE 27.49' (IN) 6" PVC IE 23.66' (IN) 8" PVC IE 22.83' (OUT) 8" PVC IE 22.77'S WVWV W W W W W W W W W W W W W W W W W W W W W W W W W W S TRANS PAD W W W V WV W V WV GVGV WV FFE=35. 5 0 1 STOR Y L I B R A R Y B U I L D I N G TYP.TY P . ALIGN 45° TYP. TY P . ALIGN AL I G N ALIGN 90°' TYP.90° TYP . TYP. TYP. ALIGN TY P . TYP. R 1 8 . 0 ' TY P . 90°' 90°' 2 ROWS OF RUNNING BOND PAVERS TY P . R21 . 4 ' A L I G N R1 0 . 0 ' R13 . 5 ' R3' R5 ' R5 . 5 ' R 6 . 3 ' R 3 0 ' R9.5 ' COVERED PAVILION, SEE ARCH TYP. 90°' TY P . TYP. TYP . 3.0 ' 7. 2 ' 2.0' 3 . 0 ' 6. 2 ' 16.0' 3. 5 ' 15' 1 4 ' 1 3 ' EQ E Q 5. 0 ' 17 . 3 ' 7. 0 ' 5.0' 12 . 0 ' 4.6' 5 . 0 ' 12' EQ EQ EQ EQ 15 . 5 ' 18.5' 2.0' EQ EQ 5.5' 2.3 '8.5 ' 15.0' 6 . 0 ' EQ EQ EQ 5.0 ' 2.0' EQ EQ 4. 0 ' 5.5' 5.25' 4' 5.0' 2.0' 10 . 0 ' 2 2 . 0 ' 4 . 5 ' 5.0' 24 . 6 ' 1 8 . 6 ' 2.5' 6. 7 5 ' 5' MIN 4 . 0 ' 4.0' 2.5' 32.5' 1.5' 7' 3.0'0.5 ' EQ EQ EQ EQ 6.0' EQ EQ 4.8 ' 5.0 ' 5.0 ' 5.0 ' 5.0 ' 2.0' 4. 0 ' 5' 6' MIN EQ EQ 2.5' 20 . 0 ' 5 ' M I N 3' 7' 2.5' 5.5' 2.8' 4' 0. 5 ' 68 . 0 ' 20 ' 22 ' 9' 2 3 ' 4' 9' 43' 17 ' 10.5' 12 ' 8.0' 18.5' 5.0' 5.0 ' 6 . 7 5 ' 5 . 5 ' 3 . 5 ' 1. 0 ' 3.75' 2' R1 0 . 0 ' 1 0 . 0 ' 110° 2.75' 29.25' 2. 2 5 ' R4. 7 5 ' AL I G N 6. 0 ' 6. 0 ' 6 . 0 ' 29 . 2 5 ' 3' 2. 2 5 ' 3' 21.5' 23 . 0 ' 3 . 0 ' R2.0' 50.5' 52.25' 52.25' 1. 5 ' 1 . 5 ' 1 . 5 ' 1. 2 5 ' 3' 2' 56.25' 1.25' 1.25' 4.25' TYP.0.5' 2 . 5 ' 5.5 ' 8. 5 ' 10.25' 11 . 5 ' 9.2 5 ' 5.0 ' 125°' 120°' 17' 5 . 5 ' 8.25' 5 . 7 5 ' EQ EQ TY P . TYP.0.5' 2. 5 ' 12' ALIGN R7.8 ' R7.0' R6.7' 1 0 . 0 ' R3.7' R10 . 7 5 ' R5.00' R 2 8 . 2 5 ' 53.25' 12 ' 1 0 . 0 0 ' 57.25' 2 8 . 5 0 ' 7 . 5 ' 73 . 7 5 ' CAUTION!!! THE LOCATIONS AND ELEVATIONS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THIS DRAWING ARE ONLY APPROXIMATE. NO GUARANTEE IS EITHER EXPRESS OR IMPLIED AS TO THE COMPLETENESS OF ACCURACY THEREOF. THE CONTRACTOR SHALL BE EXCLUSIVELY RESPONSIBLE FOR DETERMINING THE EXACT UTILITY LOCATIONS AND ELEVATIONS PRIOR TO THE START OF CONSTRUCTION. 1" = 0 GRAPHIC SCALE 20'-0" 20 10 20 40 80 L101 LAYOUT PLAN 1 LIMITS OF CONSTRUCTION (2.96 ac.) 2 CONCRETE SIDEWALK - SEE CIVIL 3 HEAVY DUTY CONCRETE SIDEWALK - SEE CIVIL 4 CONCRETE MULTI-USE TRAIL - SEE CIVIL 5 PAVERS - HEAVY DUTY VEHICULAR, UNILOCK ECO-PRIORA PAVER, HERRINGBONE PATTERN WITH SOLDIER COURSE EDGE 6 PERMEABLE PAVERS - LIGHT DUTY PEDESTRIAN, UNILOCK ECO-PRIORA PAVER, HERRINGBONE PATTERN WITH SOLDIER COURSE EDGE - SEE DETAIL 1/L300 7 FIRE LANE, GRASS PAVE - SEE CIVIL 8 RIVER ROCK, 2-4" STONES - SEE DETAIL 3/L300 9 RIVER ROCK, 6-8" STONES - SEE DETAIL 3/L300 10 STEEL BED EDGING - SEE DETAIL 4/L300 11 PEDESTRIAN BRIDGE - BY OTHERS 12 SOD - SEE PLANTING PLANS 13 SHRUB AND PERENNIAL PLANTING - SEE PLANTING PLANS F1 POLE LIGHT, VEHICULAR - SEE ELECTRICAL FOR PRODUCT AND MOUNTING DETAIL F2 POLE LIGHT, PEDESTRIAN - SEE ELECTRICAL FOR PRODUCT AND MOUNTING DETAIL F3 BENCH - VESTRE 5506h COAST SEAT WITH OWNERLESS OCEAN PLASTIC, SURFACE MOUNTED F4 CAFE TABLE AND CHAIRS - VESTRE 3713 AND 3731 BERLIN TABLE AND CHAIRS ANCHORING WITH BASE PLATE, RAL 5021 WATER BLUE, STANDARD WOOD F5 ADIRONDACK CHAIR - ANOVA PLANK ADIRONDACK CHAIR HDPE (PLK60R), DRIFTWOOD GRAY - WOODGRAIN F6 PICNIC TABLE & BENCHES -VESTRE 753 APRIL PICNIC TABLE L1500, ADA MODEL WITH BACKREST 1 SIDE, RAL 5020 OCEAN BLUE, STANDARD WOOD F7 PICNIC TABLE & BENCHES -VESTRE 751 APRIL PICNIC TABLE L1500, ADA MODEL WITHOUT BACKRESTS, RAL 5020 OCEAN BLUE, STANDARD WOOD F8 BIKE RACK - VESTRE 686C VROOM BICYCLE RACK SMALL, CASTING IN THE GROUND, RAL 5021 WATER BLUE - SEE DETAIL 2/L300 F9 TRASH & RECYCLING RECEPTACLE - VESTRE 642 VROOM LITTER BIN 80L, HOT-DIP GALVANIZED AND POWDERCOATED STEEL, RAL 5020 OCEAN BLUE - PROVIDED BY NHC F10 BOULDERS - SEE DETAIL 6/L300 F11 CONCRETE BOLLARDS - SEE CIVIL F12 WAYFINDING & EDUCATIONAL SIGNAGE F13 ENTRY MONUMENT SIGN - SEE ELECTRICAL FOR POWER F14 ADD ALTERNATE: CUSTOM TIERED TIMBER BENCH - SEE DETAIL 5/L300 MATERIALS LEGEND: 514.18349.00 08.07.2024 NORTHCHASE BRANCH LIBRARY NO.REASON DATE TRC FINAL APPROVAL Jerry Guerrier, AIA Charlie Hagen-Cazés, AIA R. Florence, PLA, M. Sweitzer 2024 4400 Northchase Parkway NE Wilmington NC 28405 c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER ISSUE FOR ISSUE DATE PREPARED FROM INFORMATION PROVIDED BY THE CONTRACTOR CONSTRUCTING THE PROJECT. DESIGNER DOES NOT WARRANT THE INFORMATION HEREIN TO BE COMPLETE, ACCURATE, OR ALL ENCOMPASSING. RECORD DRAWINGS w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little LAYOUT NOTES A.ALL PAVING CUTS SHALL BE MADE BY SAW CUTS. B.EXISTING ELEVATIONS SHALL BE FIELD VERIFIED AND MATCHED. C.CONTRACTOR TO COORDINATE ANY CHANGES IN FIELD CONDITIONS THAT MAY REVISE THE DESIGN WITH DESIGNER OF RECORD PRIOR TO PROCEEDING. D.ALL DIMENSIONS ARE TO FACE OF CURB OR TO FINISHED FACE OF BUILDING UNLESS NOTED OTHERWISE. E.ALL WORK WITHIN THE RIGHT OF WAY OF ALL ROADS AND HIGHWAYS SHALL BE IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE APPROPRIATE STATE AND/OR LOCAL JURISDICTION. CONTRACTOR SHALL SECURE ALL NECESSARY DRIVEWAY AND ENCROACHMENT PERMITS PRIOR TO CONSTRUCTION. IF NECESSARY, CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL DURING CONSTRUCTION WITHIN THE RIGHT OF WAY, PER WORK AREA TRAFFIC CONTROL HANDBOOK (W.A.T.C.H.) STANDARDS. F.A MINIMUM OF 18" IS TO BE MAINTAINED BETWEEN ALL PAVED SURFACES AND TOPS OF FOOTINGS. G. CONTRACTOR TO INSTALL TEMPORARY SEEDING IN ALL DISTURBED AREAS NOT COVERED BY PAVEMENT UPON COMPLETION OF CONSTRUCTION. CONTRACTOR TO INSTALL PERMANENT SEEDING DURING APPROPRIATE SEEDING SEASON. H.BENCHES AND PICNIC TABLES TO BE SURFACE MOUNTED PER MANUFACTURING INSTRUCTIONS. I.ALL SITE FURNITURE TO BE OWNER PROVIDED, GENERAL CONTRACTOR INSTALLED J.CONTRACTOR TO LOCATE LIGHTS IN THE FIELD AND SUBMIT PHOTOGRAPHS OF FLAGGED LOCATIONS TO LANDSCAPE ARCHITECT APPROVAL PRIOR TO DUKE ENERGY INSTALLATION X X X X 11 5 1 5 " R C P C L I V 1 5 " R C P C L I V 18" RC P C L I V FDC FH-26" W 8" DIP W (FIRE) 6" D I P W 4 " D I P W 6" P V C S E W E R 6" P V C S E W E R 6" PVC SEWER 15" R C P C L I V 15" RCP X X X X X X X X X X X X X X X X X X X X X X X X X X X CL IV 8 15" RCP 2 " D I P W ( D O M ) 8 " D I P W ( F I R E ) 6" P V C S E W E R 6 " P V C S E W E R DO N O T E N T E R 8" D I P W ( F I R E ) 8" P V C S D PVC S D 8 " 8 " P V C S D 8" PVC SD 12" PVC SD 8" PVC SD 8" 8" CL lllHDPE24" 2" D I P W ( D O M ) (FIR E ) 2" D I P W ( D O M ) FH-1 GV R P D A R P 8" D I P W ( F I R E ) 6" P V C S E W E R CL I l l 17 20 20 18 REF. FE C FE C FEC FE C FE C FEC NORTH C H A S E P A R K W A Y N E PUBLIC R / W V A R I E S T 4" PVC STUBOUT X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-002-000 18" RCP FES IE 32.25' 18" RCP FES IE 28.88' 18" RCP POND OUTLET IE 32.11' POND SPILLWAY 15" CLAY PIPE IE 29.44' 15" CLAY PIPE IE 29.35' 4" PVC STUBOUT S SSMH RIM 34.85' (IN) 6" PVC IE 28.85' (IN) 8" PVC IE 27.49' (IN) 6" PVC IE 23.66' (IN) 8" PVC IE 22.83' (OUT) 8" PVC IE 22.77'S WVWV W W W W W NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 W W W W W W W W W W W W W W W W W W W W W S NC GRID COORDINATES: NORTHING: 206403.36' NC GRID COORDINATES: NORTHING: 206729.27' EASTING: 2338354.46' TRANS PAD 101W W W V WV W V WV FIBER OPTICS MARKER GVGV WV FFE=35 . 5 0 IRRIGATION CONTROL BOX TO BE LOCATED IN MECH. ROOM - SEE ELECTRICAL QUNU 1 NYSY 1 QUNU 1 QUNU 1 NYSY 1 QUNU 1NYSY 1 NYSY 2 TADI 1 QUVI 4 JUVI 18 QUNU 6 PIPA 4 JUVI 15 QUVI 3 PIPA 8 NYSY 7 CHVI 1 JUVS 28 TADI 2 PIPA 1 PIPA 1 PIPA 2 1 STOR Y L I B R A R Y B U I L D I N G CHVI 3 TADI 1 PIPA 1 JUVI 3 QUVI 1 PIPA 1 JUVI 2 JUVI 12 QUNU 3 TADI 6 PIPA 4 QUVI 1 QUNU 1 JUVI 1 TADI 3 CAUTION!!! THE LOCATIONS AND ELEVATIONS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THIS DRAWING ARE ONLY APPROXIMATE. NO GUARANTEE IS EITHER EXPRESS OR IMPLIED AS TO THE COMPLETENESS OF ACCURACY THEREOF. THE CONTRACTOR SHALL BE EXCLUSIVELY RESPONSIBLE FOR DETERMINING THE EXACT UTILITY LOCATIONS AND ELEVATIONS PRIOR TO THE START OF CONSTRUCTION. 1" = 0 GRAPHIC SCALE 20'-0" 20 10 20 40 80 LANDSCAPE CALCULATIONS & UDO REQUIREMENTS: A.STREET YARD REQUIREMENTS (5.4.6.C) NORTHCHASE PKWY (EXCLUDING DRIVES & EASEMENTS) 1.ZONING: PD, WITH B-2 UNDERLYING ZONING, STREETYARD FACTOR = 25 7 TREES REQUIRED. | 9 PROVIDED 177 LF * 25= 4,425/ 600=7.38 44 SHRUBS REQUIRED. | 58 PROVIDED 7.38*6 --N COLLEGE ST: EXEMPT, AREAS DESIGNATED FOR STORMWATER FUNCTIONS SHALL NOT BE INCLUDED IN THE REQUIRED STREET YARD AREA. B. GENERAL STANDARDS (5.4.2.B): 1.NEW TREES PLANTED (2" cal. min.): 153 2.REQUIRED: 45 | PROVIDED: 153 (2.9 ACRES * 15 = 45) B.PARKING LOT INTERIORS (5.4.5.C) 1.8% OF TOTAL AREA FOR PARKING TO BE LANDSCAPED 1.1.REQUIRED: 4051.2 SQ FT | PROVIDED 4170.6 SQ FT 50,640 SQ FT * .08 = 4051.2 2.1 TREE REQUIRED PER 144 SQ FT OF LANDSCAPED AREA 2.1.REQUIRED: 28 TREES | PROVIDED 45 TREES D. FOUNDATION PLANTINGS (5.4.7) 1.12% OF THE AREA OF THE FIRST FLOOR BUILDING FACE ADJACENT TO THE PARKING AREA 1.1.REQUIRED: 496 SQ FT | PROVIDED: 639 SQ FT 4134 SQ FT * .12 = 496 SQ FT MAINTENANCE NOTES A.OWNER SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL REQUIRED LANDSCAPING BY KEEPING LAWNS MOWED, ALL PLANTS MAINTAINED AS DISEASE FREE, ALL PLANTING BEDS GROOMED AND KEPT WEED FREE (EXCEPT IN AREAS OF PRESERVED EXISTING NATURAL VEGETATION (I.E., THICKETS), AND KEPT FREE FROM TRASH, DEBRIS AND OTHER OBJECTIONABLE MATERIALS. B.THE REPLACEMENT OF ANY REQUIRED PLANTING, WHICH IS REMOVED OR DIES AFTER THE DATE OF PLANTING, SHALL BE REPLACED DURING THE NEXT PLANTING SEASON; AND THE REPLACEMENT OF ANY TREE IN A TREE SAVE AREA, WHICH IS REMOVED OR DIES AFTER THE DATE OF APPROVAL OF A PRESERVATION LANDSCAPE PLAN, SHALL BE DURING THE NEXT PLANTING SEASON. 514.18349.00 08.07.2024 NORTHCHASE BRANCH LIBRARY NO.REASON DATE TRC FINAL APPROVAL Jerry Guerrier, AIA Charlie Hagen-Cazés, AIA R. Florence, PLA, M. Sweitzer 2024 4400 Northchase Parkway NE Wilmington NC 28405 c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER ISSUE FOR ISSUE DATE PREPARED FROM INFORMATION PROVIDED BY THE CONTRACTOR CONSTRUCTING THE PROJECT. DESIGNER DOES NOT WARRANT THE INFORMATION HEREIN TO BE COMPLETE, ACCURATE, OR ALL ENCOMPASSING. RECORD DRAWINGS w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little L200 TREE PLANTING PLAN LANDSCAPE AND PLANTING NOTES A.MINIMUM TREE SIZE AT PLANTING IS 2" CALIPER (FOR SINGLE STEM TREES). B.ALL MULTI-STEM PLANTS MUST BE TREE FORM, MAXIMUM 3" TO 5" TRUNKS, AND MINIMUM 8' TALL. C.ALL NEW PLANTING AREAS (GRASS/TURF, SOD, PLANTS, TREES, SHRUBS, GROUNDCOVER, ETC.) SHALL BE FINE GRADED PRIOR TO INSTALLATION. FINE GRADING SHALL CONSIST OF UNCOMPACTED SOIL THAT IS HAND RAKED, SMOOTH, AND FREE OF DEBRIS (NO STONES, ROOTS, OR ANY OTHER MATERIAL GREATER THAN 1" IN SIZE). D.TILL SOIL TO A DEPTH OF 24" FOR TREES AND SHRUBS AND 6" FOR GRASS/TURF. AMEND THE TOP 24" OF SOIL FOR TREES AND SHRUBS AND TOP 6" OF SOIL FOR GRASS/TURF TO MEET TOPSOIL/PLANTING MIX STANDARDS AS REQUIRED BY SPECIFICATIONS. E.CONTRACTOR IS REQUIRED TO PERFORM SOIL TESTS TO DETERMINE SOIL NUTRIENT REQUIREMENTS FOR ALL GRASS/TURF, SOD, PLANT, TREE, SHRUB, AND GROUNDCOVER AREAS. CONTRACTOR TO SUBMIT SOIL TEST TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO MOBILIZATION. F.IN ADDITION TO THE SOIL MIXTURE, CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND INSTALLING SOIL AMENDMENTS, AS INDICATED BY SOIL TESTS, AS WELL AS, AN ADEQUATE DRAINAGE SYSTEM FOR PLANTING BEDS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING AN ENVIRONMENT SUITABLE FOR THE GROWTH OF HEALTHY PLANT MATERIAL. THE LANDSCAPE ARCHITECT MAY REQUIRE ADDITIONAL SOIL AMENDMENTS AND EXCAVATION OF EXISTING SOIL DURING ONSITE OBSERVATIONS PRIOR TO OR AFTER CONSTRUCTION. REFER TO PLANTING DETAILS FOR INFORMATION ON PLANTING BED PREPARATIONS. ALL PLANTING BEDS WILL BE PROBED BY THE LANDSCAPE ARCHITECT TO DETERMINE DEPTH AND SOIL QUALITY FOLLOWING INSTALLATION. G.ALL PLANTING BEDS AND SOD/TURF/SEEDED AREAS TO RECEIVE AN AMENDED SOIL MIXTURE. SOIL MIX SHALL BE COMPOSED OF 75% EXISTING SOIL, 15% ORGANIC MATERIAL, AND 10% SAND. SUPPLEMENT SOIL MIX WITH NITROGEN CONCENTRATION AS DETERMINED BY SOIL TEST RESULTS. H.SITE LIGHT POLES GREATER THAN 15' TALL MUST BE A MINIMUM OF 30' AWAY FROM ALL TREES. SITE LIGHT POLES LESS THAN 15' TALL MUST BE A MINIMUM OF 15' AWAY FROM ALL TREES. I.ENSURE ALL TREES ARE A MINIMUM OF 15' FROM ALL UNDERGROUND UTILITIES (GAS, WATER, PHONE, AND ELECTRICAL LINES). CONTACT LANDSCAPE ARCHITECT IF FIELD MODIFICATIONS ARE REQUIRED. J.NOTIFY LANDSCAPE ARCHITECT OF ANY SITE CONDITIONS WHICH MAY NECESSITATE MODIFICATIONS TO THE APPROVED PLANS. LANDSCAPE ARCHITECT SHALL, IF NECESSARY, MAKE "IN-FIELD MODIFICATIONS". K.ALL DISTURBED AREAS SHALL BE LANDSCAPED (GRASS/TURF, SOD, PLANTS, TREES, SHRUBS, GROUNDCOVER, ETC.). ALL AREAS NOT DESIGNATED AS PLANTING BEDS OR SOD ARE TO BE SEEDED WITH GRASS SEED UNTIL A PERMANENT STAND OF GRASS IS ESTABLISHED PER THE SPECIFICATIONS. L.CONTRACTOR IS RESPONSIBLE FOR INSPECTION OF EXISTING CONDITIONS AND PROMPTLY REPORTING ANY DISCREPANCIES TO LANDSCAPE ARCHITECT. M.CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES. ANY DAMAGE TO UTILITIES SHALL BE REPAIRED AT THE EXPENSE OF THE CONTRACTOR. N.LARGE MATURING TREES MAY NOT BE PLANTED WHERE OVERHEAD DISTRIBUTION OR TRANSMISSION LINES EXIST. IF TREES CONFLICT WITH POWER LINES, SIGNS, UNDERGROUND UTILITIES, OR ANY OTHER SITE FEATURES, CONTACT LANDSCAPE ARCHITECT BEFORE PLANTING. O.CONTRACTOR VERIFIES THAT ALL PLANT MATERIAL IS AVAILABLE AS SPECIFIED WHEN BID/PROPOSAL IS SUBMITTED AND SAID MATERIAL AS SPECIFIED IS ALSO AVAILABLE AT TIME OF INSTALLATION. NO SUBSTITUTIONS DUE TO PLANT AVAILABILITY WILL BE APPROVED. P.PLANT SCHEDULE WAS PREPARED FOR ESTIMATING PURPOSES. CONTRACTOR SHALL MAKE OWN QUANTITY TAKEOFFS USING PLANS TO DETERMINE FINAL QUANTITIES. PROMPTLY REPORT ANY DISCREPANCIES WHICH MAY AFFECT BIDDING. GRAPHIC REPRESENTATION OF PLANTS SHALL SUPERCEDE QUANTITIES LISTED IN THE PLANT SCHEDULE. Q.ROOT TYPE MAY BE FREELY SUBSTITUTED FOR BALLED AND BURLAPPED OR CONTAINER GROWN PLANTS (UNLESS NOTED AS SPECIMEN TREES ON PLANT SCHEDULE). ALL OTHER SPECIFICATIONS ARE TO REMAIN UNCHANGED (HEIGHT, WIDTH, ETC.). R.FOR ALL TREES, SHRUBS, GROUNDCOVERS AND SOD - CONTRACTOR TO APPLY A PRE-EMERGENT HERBICIDE, 'PREEN' OR EQUAL TO ALL PLANT BED AREAS AND PROVIDE DOCUMENTATION OF QUANTITY AND PRODUCT USED TO LANDSCAPE ARCHITECT PRIOR TO FINAL PROJECT APPROVAL. S.FOR ALL SEEDED GRASS/TURF - REMOVE WEEDS BEFORE SEEDING. WHERE WEEDS ARE PRESENT, APPLY SELECTIVE HERBICIDES TO ELIMINATE ALL WEEDS. DO NOT USE PRE-EMERGENCE HERBICIDES. T.CONTRACTOR IS TO PROVIDE OWNER AN ESTABLISHED, HEALTHY, UNIFORM, CLOSE STAND OF GRASS, FREE OF WEEDS AND SURFACE IRREGULARITIES, WITH COVERAGE EXCEEDING 90% OVER ANY 10 SQ FT AREA AND BARE SPOTS ARE NOT TO EXCEED 5 BY 5 INCHES. U.ALL PLANT MATERIAL MUST BE PLANTED IN CORRELATION WITH THE APPROPRIATE GROWING SEASON OF INDIVIDUAL PLANT REQUIREMENTS. SOME PERENNIALS MAY REQUIRE A SPRING PLANTING IN ORDER TO SURVIVE A FULL WINTER DORMANCY. V.ALL PLANT MATERIAL AND WORKMANSHIP TO BE GUARANTEED FOR ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE OWNER. REPLACEMENT PLANTS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THIS DOCUMENT AND SPECIFICATIONS. THE CONTRACTOR WILL NOT BE RESPONSIBLE FOR DEFECTS RESULTING FROM NEGLECT BY THE OWNER, ABUSE OR DAMAGE BY OTHERS. W.ALL STRAPPING AND TOP 2/3 OF WIRE BASKET MUST BE CUT AWAY AND REMOVED FROM ROOT BALL PRIOR TO BACKFILLING THE PLANTING PIT. REMOVE TOP 1/3 OF THE BURLAP FROM ROOT BALL. IRRIGATION NOTES A.ALL SODDED TURF AREAS (SEEDED AREAS EXCLUDED) ARE TO BE IRRIGATED WITH SPRAY HEADS AND ALL PLANTING AREAS TO BE IRRIGATED WITH DRIP IRRIGATION. ALL PHASES OF INSTALLATION TO BE INSPECTED BY LANDSCAPE ARCHITECT. B.CONTRACTOR TO PROVIDE IRRIGATION CONTROLLER WITH WEATHER STATION TO OPTIMIZE WATER CONSERVATION. C.CONTRACTOR SHALL VERIFY THAT AVAILABLE WATER PRESSURE IS ADEQUATE FOR IRRIGATION SYSTEM. PRIOR TO BEGINNING CONSTRUCTION, CONTRACTOR SHALL FIELD VERIFY ANY DISCREPANCIES AND REPORT SAID DISCREPANCIES TO THE LANDSCAPE ARCHITECT. D.CONTRACTOR TO PROVIDE IRRIGATION LAYOUT DESIGN TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO MOBILIZATION. E.CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF BACKFLOW PREVENTORS, VALVES, ELECTRIC WIRING FOR THE IRRIGATION SYSTEM, ALL SLEEVING, ALL FITTINGS, ADAPTERS, ETC. TO COMPLETE THE IRRIGATION SYSTEM. F.PER OWNER, ALL IRRIGATION SYSTEMS ARE TO BE FED FROM A WELL DRILLED ON-SITE. CONTRACTOR IS RESPONSIBLE FOR LOCATING, PERMITTING, AND DRILLING THE WELL. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE DESIGN, PERMITTING, AND INSTALLATION OF ALL PUMPS, FILTRATION SYSTEMS, OR ANY ADDITIONAL INFRASTRUCTURE THAT MAY BE REQUIRED TO PROVIDE A COMPLETE OPERATING WELL SYSTEM AS PART OF THE IRRIGATION SYSTEM. G.CONTRACTOR SHALL ADJUST ALL HEADS IN FIELD TO ENSURE MAXIMUM COVERAGE, AND ELIMINATE OVERTHROW ONTO PAVED AREAS, BUILDING AND WALL SURFACES (LOCATE HEADS 3" CLEAR OF ALL HARDSCAPE SURFACES). ALL AUTOMATIC VALVES SHALL BE INSTALLED IN A VALVE BOX AS SPECIFIED. COORDINATE SLEEVES WITH GENERAL CONTRACTOR. H.CONTRACTOR SHALL COORDINATE PIPING LAYOUT WITH LANDSCAPE PLAN TO ENSURE PIPES DO NOT INTERFERE WITH ROOT BALLS OF TREES OR ROWS OF SHRUBS. REPORT ANY DISCREPANCIES TO THE LANDSCAPE ARCHITECT. I.CONTRACTOR SHALL VERIFY THAT ALL LOCAL AND STATE CODES ARE BEING OBSERVED. J.CONTRACTOR TO PROVIDE THRUST BLOCKS ON 3" MAIN AT ALL BENDS AND TURNS. K.PROVIDE IRRIGATION TO ALL STREET TREES WITHIN PROJECT LIMITS. L.PROVIDE GATE VALVES AT DOWNSTREAM SIDE OF BACKFLOW AND AT HYDRAULIC CONTROLLERS. M.CONTRACTOR SHALL DESIGN AND INSTALL A COMPLETE FUNCTIONING IRRIGATION SYSTEM FOR ALL GRASS/TURF AND PLANTING AREAS WITHIN PROJECT CONSTRUCTION LIMITS. N.PLANS SHALL INCLUDE A COMPLETE SEPARATION OF SHRUB AND TURF AREAS. PLANS SHALL INCLUDE CONTROLLER, ALL SLEEVING, ELECTRIC VALVES, HEADS LATERALS, MAINS, DRIP LINES CONNECTIONS TO EQUIPMENT, AND ALL OTHER COMPONENTS NECESSARY FOR A WORKING IRRIGATION SYSTEM. O.ALL CONTROLLERS, VALVES AND HEADS TO BE MADE BY THE SAME MANUFACTURER. P.BACKFLOW PREVENTOR TO BE PROVIDED BY CONTRACTOR AND SHALL CONFORM TO REQUIREMENTS OF LOCAL AUTHORITIES. Q.SEE ELECTRICAL PLANS FOR LOCATION OF CONTROLLER BOX. X X X X 11 5 1 5 " R C P C L I V 1 5 " R C P C L I V 18" RC P C L I V FDC FH-26" W 8" DIP W (FIRE) 6" D I P W 4 " D I P W 6" P V C S E W E R 6" P V C S E W E R 6" PVC SEWER 15" R C P C L I V 15" RCP X X X X X X X X X X X X X X X X X X X X X X X X X X X CL IV 8 15" RCP 2 " D I P W ( D O M ) 8 " D I P W ( F I R E ) 6" P V C S E W E R 6 " P V C S E W E R DO N O T E N T E R 8" D I P W ( F I R E ) 8" P V C S D PVC S D 8 " 8 " P V C S D 8" PVC SD 12" PVC SD 8" PVC SD 8" 8" CL lllHDPE24" 2" D I P W ( D O M ) (FIR E ) 2" D I P W ( D O M ) FH-1 GV R P D A R P 8" D I P W ( F I R E ) 6" P V C S E W E R CL I l l 17 20 20 18 REF. FE C FE C FEC FE C FE C FEC NORTH C H A S E P A R K W A Y N E PUBLIC R / W V A R I E S T 4" PVC STUBOUT X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X NORTHCHASE HOA MB 2117 PG 18 PID: R02611-001-001-000 GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-004-000 GSI WILMINGTON ENTERPRISE LLC MB 6390 PG 1240 PID: R02611-002-002-000 18" RCP FES IE 32.25' 18" RCP FES IE 28.88' 18" RCP POND OUTLET IE 32.11' POND SPILLWAY 15" CLAY PIPE IE 29.44' 15" CLAY PIPE IE 29.35' 4" PVC STUBOUT S SSMH RIM 34.85' (IN) 6" PVC IE 28.85' (IN) 8" PVC IE 27.49' (IN) 6" PVC IE 23.66' (IN) 8" PVC IE 22.83' (OUT) 8" PVC IE 22.77'S WVWV W W W W W NORTHCHASE HOA MB 2117 PG 18 PID:R02611-001-001-000 W W W W W W W W W W W W W W W W W W W W W S NC GRID COORDINATES: NORTHING: 206403.36' NC GRID COORDINATES: NORTHING: 206729.27' EASTING: 2338354.46' TRANS PAD 101W W W V WV W V WV FIBER OPTICS MARKER GVGV WV FFE=35 . 5 0 IRRIGATION CONTROL BOX TO BE LOCATED IN MECH. ROOM - SEE ELECTRICAL 1 STOR Y L I B R A R Y B U I L D I N G MUPC 20 SSSO 69 YUFI 6 MUPC 19 JUSM 50 SSSO 55 YUFI 6 MUPC 12 YUFI 8 SSSO 85 JUSM 28 JUSM 6 MUWC 14 YUFI 7 MUPC 26 MUPC 116 SSSO 117 COCA 26 YUFI 8 SPHE 15 JUSM 13 YUFI 20 DARA 17 ILGL 16 ILVO 32 SAMI 4 COCA 11 MUPC 118 ILVO 10 IRVE 16 SSSO 78 COCA 4 JUSM 9 MUPC 4 COCA 3 JUSM 3 MUPC 3 COCA 3 MUPC 3 CABL 6 COCA 5 CABL 34 JUSM 1 MUPC 13 MUPC 6 COCA 9 IRVE 12 SPHE 18 CABL 31 SSSO 18 PAHM 33 ASTU 12 PAHM 52 SOFI 5 ACMI 7 RUFU 10 IRVE 10 LOCA 3 ACMI 5 RUFU 2 PAHM 12 ASCI 2 PAHM 12 SOFI 3 ASTU 4 IRVE 1 LOCA 2 MOCA 24 MUPC 54 COCA 6 JUSM 29 COCA 9 SPHE 22 SPHE 22 LOCA 7 CARR 13 YUEX 4 ILVE 9 LOCA 5 ASCI 5 IRVE 2 SOFI 3 SAMI 3 ILVM 2 SSSO 5 PAHM 1 ASTU 2 ITVI 7 PAHM 50 CABL 17 CABL 25 CABL 12 JUSM 4 COCA 6 MUPC 10 SSSO 13 CABL 15 JUSM 11 COCA 5 SSSO 15 MUPC 7 YUFI 1 MUPC 3 SSSO 5 COCA 3 YUFI 2 ACMI 3 RUFU 1 CABL 103 ILVO 24 PAHM 29 MOCA 15 ILVO 4 MOCA 5 PAHM 12 ILVO 6 PAHM 43 CAUTION!!! THE LOCATIONS AND ELEVATIONS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THIS DRAWING ARE ONLY APPROXIMATE. NO GUARANTEE IS EITHER EXPRESS OR IMPLIED AS TO THE COMPLETENESS OF ACCURACY THEREOF. THE CONTRACTOR SHALL BE EXCLUSIVELY RESPONSIBLE FOR DETERMINING THE EXACT UTILITY LOCATIONS AND ELEVATIONS PRIOR TO THE START OF CONSTRUCTION. 1" = 0 GRAPHIC SCALE 20'-0" 20 10 20 40 80 LANDSCAPE AND PLANTING NOTES A.MINIMUM TREE SIZE AT PLANTING IS 2" CALIPER (FOR SINGLE STEM TREES). B.ALL MULTI-STEM PLANTS MUST BE TREE FORM, MAXIMUM 3" TO 5" TRUNKS, AND MINIMUM 8' TALL. C.ALL NEW PLANTING AREAS (GRASS/TURF, SOD, PLANTS, TREES, SHRUBS, GROUNDCOVER, ETC.) SHALL BE FINE GRADED PRIOR TO INSTALLATION. FINE GRADING SHALL CONSIST OF UNCOMPACTED SOIL THAT IS HAND RAKED, SMOOTH, AND FREE OF DEBRIS (NO STONES, ROOTS, OR ANY OTHER MATERIAL GREATER THAN 1" IN SIZE). D.TILL SOIL TO A DEPTH OF 24" FOR TREES AND SHRUBS AND 6" FOR GRASS/TURF. AMEND THE TOP 24" OF SOIL FOR TREES AND SHRUBS AND TOP 6" OF SOIL FOR GRASS/TURF TO MEET TOPSOIL/PLANTING MIX STANDARDS AS REQUIRED BY SPECIFICATIONS. E.CONTRACTOR IS REQUIRED TO PERFORM SOIL TESTS TO DETERMINE SOIL NUTRIENT REQUIREMENTS FOR ALL GRASS/TURF, SOD, PLANT, TREE, SHRUB, AND GROUNDCOVER AREAS. CONTRACTOR TO SUBMIT SOIL TEST TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO MOBILIZATION. F.IN ADDITION TO THE SOIL MIXTURE, CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND INSTALLING SOIL AMENDMENTS, AS INDICATED BY SOIL TESTS, AS WELL AS, AN ADEQUATE DRAINAGE SYSTEM FOR PLANTING BEDS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING AN ENVIRONMENT SUITABLE FOR THE GROWTH OF HEALTHY PLANT MATERIAL. THE LANDSCAPE ARCHITECT MAY REQUIRE ADDITIONAL SOIL AMENDMENTS AND EXCAVATION OF EXISTING SOIL DURING ONSITE OBSERVATIONS PRIOR TO OR AFTER CONSTRUCTION. REFER TO PLANTING DETAILS FOR INFORMATION ON PLANTING BED PREPARATIONS. ALL PLANTING BEDS WILL BE PROBED BY THE LANDSCAPE ARCHITECT TO DETERMINE DEPTH AND SOIL QUALITY FOLLOWING INSTALLATION. G.ALL PLANTING BEDS AND SOD/TURF/SEEDED AREAS TO RECEIVE AN AMENDED SOIL MIXTURE. SOIL MIX SHALL BE COMPOSED OF 75% EXISTING SOIL, 15% ORGANIC MATERIAL, AND 10% SAND. SUPPLEMENT SOIL MIX WITH NITROGEN CONCENTRATION AS DETERMINED BY SOIL TEST RESULTS. H.SITE LIGHT POLES GREATER THAN 15' TALL MUST BE A MINIMUM OF 30' AWAY FROM ALL TREES. SITE LIGHT POLES LESS THAN 15' TALL MUST BE A MINIMUM OF 15' AWAY FROM ALL TREES. I.ENSURE ALL TREES ARE A MINIMUM OF 15' FROM ALL UNDERGROUND UTILITIES (GAS, WATER, PHONE, AND ELECTRICAL LINES). CONTACT LANDSCAPE ARCHITECT IF FIELD MODIFICATIONS ARE REQUIRED. J.NOTIFY LANDSCAPE ARCHITECT OF ANY SITE CONDITIONS WHICH MAY NECESSITATE MODIFICATIONS TO THE APPROVED PLANS. LANDSCAPE ARCHITECT SHALL, IF NECESSARY, MAKE "IN-FIELD MODIFICATIONS". K.ALL DISTURBED AREAS SHALL BE LANDSCAPED (GRASS/TURF, SOD, PLANTS, TREES, SHRUBS, GROUNDCOVER, ETC.). ALL AREAS NOT DESIGNATED AS PLANTING BEDS OR SOD ARE TO BE SEEDED WITH GRASS SEED UNTIL A PERMANENT STAND OF GRASS IS ESTABLISHED PER THE SPECIFICATIONS. L.CONTRACTOR IS RESPONSIBLE FOR INSPECTION OF EXISTING CONDITIONS AND PROMPTLY REPORTING ANY DISCREPANCIES TO LANDSCAPE ARCHITECT. M.CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES. ANY DAMAGE TO UTILITIES SHALL BE REPAIRED AT THE EXPENSE OF THE CONTRACTOR. N.LARGE MATURING TREES MAY NOT BE PLANTED WHERE OVERHEAD DISTRIBUTION OR TRANSMISSION LINES EXIST. IF TREES CONFLICT WITH POWER LINES, SIGNS, UNDERGROUND UTILITIES, OR ANY OTHER SITE FEATURES, CONTACT LANDSCAPE ARCHITECT BEFORE PLANTING. O.CONTRACTOR VERIFIES THAT ALL PLANT MATERIAL IS AVAILABLE AS SPECIFIED WHEN BID/PROPOSAL IS SUBMITTED AND SAID MATERIAL AS SPECIFIED IS ALSO AVAILABLE AT TIME OF INSTALLATION. NO SUBSTITUTIONS DUE TO PLANT AVAILABILITY WILL BE APPROVED. P.PLANT SCHEDULE WAS PREPARED FOR ESTIMATING PURPOSES. CONTRACTOR SHALL MAKE OWN QUANTITY TAKEOFFS USING PLANS TO DETERMINE FINAL QUANTITIES. PROMPTLY REPORT ANY DISCREPANCIES WHICH MAY AFFECT BIDDING. GRAPHIC REPRESENTATION OF PLANTS SHALL SUPERCEDE QUANTITIES LISTED IN THE PLANT SCHEDULE. Q.ROOT TYPE MAY BE FREELY SUBSTITUTED FOR BALLED AND BURLAPPED OR CONTAINER GROWN PLANTS (UNLESS NOTED AS SPECIMEN TREES ON PLANT SCHEDULE). ALL OTHER SPECIFICATIONS ARE TO REMAIN UNCHANGED (HEIGHT, WIDTH, ETC.). R.FOR ALL TREES, SHRUBS, GROUNDCOVERS AND SOD - CONTRACTOR TO APPLY A PRE-EMERGENT HERBICIDE, 'PREEN' OR EQUAL TO ALL PLANT BED AREAS AND PROVIDE DOCUMENTATION OF QUANTITY AND PRODUCT USED TO LANDSCAPE ARCHITECT PRIOR TO FINAL PROJECT APPROVAL. S.FOR ALL SEEDED GRASS/TURF - REMOVE WEEDS BEFORE SEEDING. WHERE WEEDS ARE PRESENT, APPLY SELECTIVE HERBICIDES TO ELIMINATE ALL WEEDS. DO NOT USE PRE-EMERGENCE HERBICIDES. T.CONTRACTOR IS TO PROVIDE OWNER AN ESTABLISHED, HEALTHY, UNIFORM, CLOSE STAND OF GRASS, FREE OF WEEDS AND SURFACE IRREGULARITIES, WITH COVERAGE EXCEEDING 90% OVER ANY 10 SQ FT AREA AND BARE SPOTS ARE NOT TO EXCEED 5 BY 5 INCHES. U.ALL PLANT MATERIAL MUST BE PLANTED IN CORRELATION WITH THE APPROPRIATE GROWING SEASON OF INDIVIDUAL PLANT REQUIREMENTS. SOME PERENNIALS MAY REQUIRE A SPRING PLANTING IN ORDER TO SURVIVE A FULL WINTER DORMANCY. V.ALL PLANT MATERIAL AND WORKMANSHIP TO BE GUARANTEED FOR ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE OWNER. REPLACEMENT PLANTS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THIS DOCUMENT AND SPECIFICATIONS. THE CONTRACTOR WILL NOT BE RESPONSIBLE FOR DEFECTS RESULTING FROM NEGLECT BY THE OWNER, ABUSE OR DAMAGE BY OTHERS. W.ALL STRAPPING AND TOP 2/3 OF WIRE BASKET MUST BE CUT AWAY AND REMOVED FROM ROOT BALL PRIOR TO BACKFILLING THE PLANTING PIT. REMOVE TOP 1/3 OF THE BURLAP FROM ROOT BALL. MAINTENANCE NOTES A.OWNER SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL REQUIRED LANDSCAPING BY KEEPING LAWNS MOWED, ALL PLANTS MAINTAINED AS DISEASE FREE, ALL PLANTING BEDS GROOMED AND KEPT WEED FREE (EXCEPT IN AREAS OF PRESERVED EXISTING NATURAL VEGETATION (I.E., THICKETS), AND KEPT FREE FROM TRASH, DEBRIS AND OTHER OBJECTIONABLE MATERIALS. B.THE REPLACEMENT OF ANY REQUIRED PLANTING, WHICH IS REMOVED OR DIES AFTER THE DATE OF PLANTING, SHALL BE REPLACED DURING THE NEXT PLANTING SEASON; AND THE REPLACEMENT OF ANY TREE IN A TREE SAVE AREA, WHICH IS REMOVED OR DIES AFTER THE DATE OF APPROVAL OF A PRESERVATION LANDSCAPE PLAN, SHALL BE DURING THE NEXT PLANTING SEASON. IRRIGATION NOTES A.ALL SODDED TURF AREAS (SEEDED AREAS EXCLUDED) ARE TO BE IRRIGATED WITH SPRAY HEADS AND ALL PLANTING AREAS TO BE IRRIGATED WITH DRIP IRRIGATION. ALL PHASES OF INSTALLATION TO BE INSPECTED BY LANDSCAPE ARCHITECT. B.CONTRACTOR TO PROVIDE IRRIGATION CONTROLLER WITH WEATHER STATION TO OPTIMIZE WATER CONSERVATION. C.CONTRACTOR SHALL VERIFY THAT AVAILABLE WATER PRESSURE IS ADEQUATE FOR IRRIGATION SYSTEM. PRIOR TO BEGINNING CONSTRUCTION, CONTRACTOR SHALL FIELD VERIFY ANY DISCREPANCIES AND REPORT SAID DISCREPANCIES TO THE LANDSCAPE ARCHITECT. D.CONTRACTOR TO PROVIDE IRRIGATION LAYOUT DESIGN TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO MOBILIZATION. E.CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF BACKFLOW PREVENTORS, VALVES, ELECTRIC WIRING FOR THE IRRIGATION SYSTEM, ALL SLEEVING, ALL FITTINGS, ADAPTERS, ETC. TO COMPLETE THE IRRIGATION SYSTEM. F.PER OWNER, ALL IRRIGATION SYSTEMS ARE TO BE FED FROM A WELL DRILLED ON-SITE. CONTRACTOR IS RESPONSIBLE FOR LOCATING, PERMITTING, AND DRILLING THE WELL. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE DESIGN, PERMITTING, AND INSTALLATION OF ALL PUMPS, FILTRATION SYSTEMS, OR ANY ADDITIONAL INFRASTRUCTURE THAT MAY BE REQUIRED TO PROVIDE A COMPLETE OPERATING WELL SYSTEM AS PART OF THE IRRIGATION SYSTEM. G.CONTRACTOR SHALL ADJUST ALL HEADS IN FIELD TO ENSURE MAXIMUM COVERAGE, AND ELIMINATE OVERTHROW ONTO PAVED AREAS, BUILDING AND WALL SURFACES (LOCATE HEADS 3" CLEAR OF ALL HARDSCAPE SURFACES). ALL AUTOMATIC VALVES SHALL BE INSTALLED IN A VALVE BOX AS SPECIFIED. COORDINATE SLEEVES WITH GENERAL CONTRACTOR. H.CONTRACTOR SHALL COORDINATE PIPING LAYOUT WITH LANDSCAPE PLAN TO ENSURE PIPES DO NOT INTERFERE WITH ROOT BALLS OF TREES OR ROWS OF SHRUBS. REPORT ANY DISCREPANCIES TO THE LANDSCAPE ARCHITECT. I.CONTRACTOR SHALL VERIFY THAT ALL LOCAL AND STATE CODES ARE BEING OBSERVED. J.CONTRACTOR TO PROVIDE THRUST BLOCKS ON 3" MAIN AT ALL BENDS AND TURNS. K.PROVIDE IRRIGATION TO ALL STREET TREES WITHIN PROJECT LIMITS. L.PROVIDE GATE VALVES AT DOWNSTREAM SIDE OF BACKFLOW AND AT HYDRAULIC CONTROLLERS. M.CONTRACTOR SHALL DESIGN AND INSTALL A COMPLETE FUNCTIONING IRRIGATION SYSTEM FOR ALL GRASS/TURF AND PLANTING AREAS WITHIN PROJECT CONSTRUCTION LIMITS. N.PLANS SHALL INCLUDE A COMPLETE SEPARATION OF SHRUB AND TURF AREAS. PLANS SHALL INCLUDE CONTROLLER, ALL SLEEVING, ELECTRIC VALVES, HEADS LATERALS, MAINS, DRIP LINES CONNECTIONS TO EQUIPMENT, AND ALL OTHER COMPONENTS NECESSARY FOR A WORKING IRRIGATION SYSTEM. O.ALL CONTROLLERS, VALVES AND HEADS TO BE MADE BY THE SAME MANUFACTURER. P.BACKFLOW PREVENTOR TO BE PROVIDED BY CONTRACTOR AND SHALL CONFORM TO REQUIREMENTS OF LOCAL AUTHORITIES. Q.SEE ELECTRICAL PLANS FOR LOCATION OF CONTROLLER BOX. 514.18349.00 08.07.2024 NORTHCHASE BRANCH LIBRARY NO.REASON DATE TRC FINAL APPROVAL Jerry Guerrier, AIA Charlie Hagen-Cazés, AIA R. Florence, PLA, M. Sweitzer 2024 4400 Northchase Parkway NE Wilmington NC 28405 c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER ISSUE FOR ISSUE DATE PREPARED FROM INFORMATION PROVIDED BY THE CONTRACTOR CONSTRUCTING THE PROJECT. DESIGNER DOES NOT WARRANT THE INFORMATION HEREIN TO BE COMPLETE, ACCURATE, OR ALL ENCOMPASSING. RECORD DRAWINGS w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little L201 UNDERSTORY PLANTING PLAN LANDSCAPE CALCULATIONS & UDO REQUIREMENTS: A.STREET YARD REQUIREMENTS (5.4.6.C) NORTHCHASE PKWY (EXCLUDING DRIVES & EASEMENTS) 1.ZONING: PD, WITH B-2 UNDERLYING ZONING, STREETYARD FACTOR = 25 7 TREES REQUIRED. | 9 PROVIDED 177 LF * 25= 4,425/ 600=7.38 44 SHRUBS REQUIRED. | 58 PROVIDED 7.38*6 --N COLLEGE ST: EXEMPT, AREAS DESIGNATED FOR STORMWATER FUNCTIONS SHALL NOT BE INCLUDED IN THE REQUIRED STREET YARD AREA. B. GENERAL STANDARDS (5.4.2.B): 1.EXISTING TREES RETAINED: 2 2.NEW TREES PLANTED (2" cal. min.): 128 3.REQUIRED: 45 | PROVIDED: 151 (2.9 ACRES * 15 = 45) C.PARKING LOT INTERIORS (5.4.5.C) 1.8% OF TOTAL AREA FOR PARKING TO BE LANDSCAPED 1.1.REQUIRED: 4051.2 SQ FT | PROVIDED 4170.6 SQ FT 50,640 SQ FT * .08 = 4051.2 2.1 TREE REQUIRED PER 144 SQ FT OF LANDSCAPED AREA 2.1.REQUIRED: 28 TREES | PROVIDED 45 TREES D. FOUNDATION PLANTINGS (5.4.7) 1.12% OF THE AREA OF THE FIRST FLOOR BUILDING FACE ADJACENT TO THE PARKING AREA 1.1.REQUIRED: 496 SQ FT | PROVIDED: 639 SQ FT 4134 SQ FT * .12 = 496 SQ FT NOTES: A.PAVERS TO BE UNILOCK ECO-PRIORA PREMIER PAVER SERIES IN HERRINGBONE PATTERN WITH SOLDIER COURSE EDGE. COLOR: STEEL MOUNTAIN, 5" X 10" 8 CM. B.LANDSCAPE ARCHITECT AND OWNER TO APPROVE PAVER COLORS, PATTERN AND FINISH PRIOR TO INSTALLATION. C.INSTALL PAVERS PER MANUFACTURER'S SPECIFICATIONS AND DETAILS. 8" RIVER ROCK, 2-4" DIAMETER EVEN WITH TOP OF CONCRETE 98% COMPACTED SUBGRADE EDGE OF BUILDING CONCRETE SIDEWALK ENSURE POSITIVE DRAINAGE FILTER FABRIC 11 . 8 " 33 . 4 " 7.8" POROUS CONCRETE PAVING IN-GROUND EMBED INTO CONCRETE BASE NOTES: A.PRODUCT: VESTRE 686C VROOM BICYCLE RACK SMALL, RAL 5020 OCEAN BLUE B.BIKE RACK GENERAL REQUIREMENTS: ·SHOULD SUPPORT THE BICYCLE UPRIGHT WITHOUT PUTTING STRESS ON THE WHEELS ·SHOULD ACCOMODATE A VARIETY OF BICYCLES AND ATTACHMENTS ·SHOULD ALLOW LOCKING OF FRAME AND AT LEAST ONE WHEEL WITH U-LOCK ·SHOULD PROVIDE SECURITY AND LONGEVITY FEATURES APPROPRIATE FOR THE INTENDED LOCATION ·SHOULD BE INTUITIVE B.BIKE RACKS SHOULD BE INSTALLED PER MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES. C.ALL DIMENSIONS SHOWN ARE MINIMUM. D.RACK MUST BE CANE DETECTABLE. RACK AND CLEARANCES SHOWN ARE TO BE OUTSIDE THE PEDESTRIAN ACCESSIBLE ROUTE. NOT TO SCALE2BIKE RACK NOT TO SCALE3RIVER ROCK AT CONCRETE EDGE NOT TO SCALE5TIERED TIMBER BENCH - PAVILION ADD ALTERNATE NOT TO SCALE4STEEL BED EDGING NOT TO SCALE6BOULDERS CROSS SLOPE MIN. 1 4" PER 1'-0" FOR DRAINAGE CUT GRANITE BOULDER GROUNDPLANE VARIES, SEE L100 SITE MATERIALS PLAN NOTES: 1.STEEL BED EDGING TO BE USED WHERE PLANTING BEDS MEET TURF. 2.THERE SHALL BE NO EXPOSED SHARP / JAGGED EDGES. 3.CONTRACTOR SHALL INSTALL STAKES AS REQUIRED BY THE MANUFACTURER. FINISHED GRADE - TOP OF SOD THATCH LAYER AND TOP OF MULCH OR STONE SHALL BE FLUSH WITH TOP OF EDGER TURF THATCH AMENDED SOIL PER SPECIFICATIONS SUBGRADE METAL EDGER - DRILL (16) 1/2" DIA. HOLES 1" O.C. MIN. AT ALL LOW POINTS OR POORLY DRAINING AREAS IN ORDER TO ENSURE ADEQUATE DRAINAGE EDGER STAKE 1 2 3 4 5 64 3 2 1 5 ENSURE POSITIVE DRAINAGE 6 SECTION LONGITUDINAL SECTION OF EDGER AT LOW POINT (16) 1/2" DIA. HOLES MIN. AT ALL LOW POINTS NOTES: A.BOULDER SIZE RANGE: 2' x 2' - 3' x 3' B.CONTRACTOR TO STOCKPILE ANY BOULDERS THAT FIT DESCRIPTION FOUND ON SITE DURING EXCAVATION AND NOTIFY LANDSCAPE ARCHITECT FOR REVIEW C.ADDITIONAL BOULDERS TO BE SOURCED FROM A LOCAL QUARRY D.LANDSCAPE ARCHITECT TO CONFIRM BOULDER STONE AND SELECT BOULDERS THROUGH PHOTOGRAPHS OR SITE VISIT 514.18349.00 08.07.2024 NORTHCHASE BRANCH LIBRARY NO.REASON DATE TRC FINAL APPROVAL Jerry Guerrier, AIA Charlie Hagen-Cazés, AIA R. Florence, PLA, M. Sweitzer 2024 4400 Northchase Parkway NE Wilmington NC 28405 c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER ISSUE FOR ISSUE DATE PREPARED FROM INFORMATION PROVIDED BY THE CONTRACTOR CONSTRUCTING THE PROJECT. DESIGNER DOES NOT WARRANT THE INFORMATION HEREIN TO BE COMPLETE, ACCURATE, OR ALL ENCOMPASSING. RECORD DRAWINGS w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little NOT TO SCALE1PERMEABLE UNIT PAVERS L300 SITE DETAILS MI N I M U M EM B A N K M E N T PERMEABLE PAVERS PERMEABLE PAVERS COLUMN FOR ARCHITECTURAL CANOPY BEYOND, SEE ARCH. 2'-6" 1' - 6 " MI N 1' - 0 " +/-1'-6" 2'-6" SEE ARCH AND STRUCTURAL FOR FOOTING CONCRETE PAD PERMEABLE PAVERSPERMEABLE PAVERS 2"X4" COMPOSITE DECK BOARDS NOTES: A.ALIGN BENCH WITH COLUMN AT CORNER. B.COMPOSITE DECKING TO BE TREX OR APPROVED EQUAL. C.LANDSCAPE ARCHITECT TO APPROVE COMPOSITE DECKING MATERIAL AND FINISH PRIOR TO INSTALLATION. D.ALL SCREWS TO BE STAINLESS STEEL. ALL OTHER HARDWARE TO BE HOT GALVANIZED DIPPED. E.ALL PRESSURE TREATED LUMBER TO BE NO.1 YELLOW PINE. 4" METAL COVER COLUMN FOR ARCHITECTURAL CANOPY, SEE ARCH (A)TIERED BENCH SECTION (B)SINGLE LEVEL BENCH SECTION (G)BENCH FRAMING PLAN - UPPER TIER (E)END FACE OF BENCH AXON PERMEABLE PAVERS 6"X6" PRESSURE TREATED LUMBER 2"X8" PRESSURE TREATED LUMBER "REDHEAD" FASTENERS 2"X6" PRESSURE TREATED LUMBER 2"X6" PRESSURE TREATED LUMBER BASE PLATE 6"X6" PRESSURE TREATED LUMBER 2"X8" PRESSURE TREATED LUMBER BUILDING EDGE 2" BEDDING ROCK (#8 STONE) JOINT STONE (1 8"-3 8" CRUSHED ROCK, NO FINES) PERMEABLE PAVERS 6" BASE COURSE (#57 STONE) 8" SUBBASE COURSE (#2 STONE) GEOTEXTILE FILTER FABRIC UNCOMPACTED SUBGRADE 2"X4" PRESSURE TREATED LUMBER 2"X4" PRESSURE TREATED LUMBER 2"X4" PRESSURE TREATED LUMBER 2"X4" COMPOSITE DECK BOARDS (2) 2"X8" PRESSURE TREATED LUMBER (2) 2"X8" PRESSURE TREATED LUMBER 6"x6" POSTS @ 8' O.C. 2"X8" @ 16" O.C. (2) 2"X8" 2"X4" COMPOSITE DECK BOARDS 2"X4" COMPOSITE DECK BOARDS (F)BENCH FRAMING PLAN - LOWER TIER (53) 2"X4" DECK BOARDS 6. 5 ' (2 3 ) 2 " X 4 " D E C K BO A R D S (8) 2"X4" DECK BOARDS 4" T Y P 4" TYP SECTION A SECTION B SECTION B (C)TIERED BENCH PLAN (D)TIERED BENCH PLAN BASIC BUTT JOINT 2"X6" 2"X6" 2"X6"2"X6" 2"X6" 2"X6" 2"X6" @ 18" O.C. (H)METAL COVER AT COLUMN 1 0 0 ° ' 100° ' NOTE: A.PLACE PLANTS IN A PREPARED BED AS SHOWN. B.SPACE AS SPECIFIED IN PLANT LIST. 6" 12 " SPACE 1 2 SPACE SPACE 12 SPACE SP A C E SP A C E 12 S P A C E ATYPICAL SPACING AT END ROW STAGGER PLANTS ATYPICAL SPACING IN CORNERS 4" MIN. MULCHFINISHED GRADE PLANTING MIXTURE PER SPECIFICATIONS 6" TY P . 6" TYP. 4" MIN. MULCH SOIL BERM FINISHED GRADE SCARIFY SIDES OF HOLE TO 4" DEPTH MIN. B&B OR CONTAINERIZED - SEE PLANT SCHEDULE FOR ROOT BALL SPECIFICATIONS; CUT AND REMOVE BURLAP FROM TOP 1/3 OF ROOT BALL PREPARED PLANTING SOIL PER SPECIFICATIONS; NOTE: WHEN GROUNDCOVERS AND SHRUBS USED IN MASSES, ENTIRE BED TO BE EXCAVATED TO RECEIVE PLANTING SOIL AND PLANT MATERIAL COMPACT PLANTING SOIL BENEATH ROOT BALL NOTES: A.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION. B.FOR SEMI-IMPERVIOUS SOIL CONDITIONS AND FOR ALL AZALEA PLANTING, ROOT BALL ELEVATION SHALL BE 2" ABOVE FINISHED GRADE. COORDINATE WITH LANDSCAPE ARCHITECT PRIOR TO SETTING ROOT BALL ELEVATIONS. 6" MIN. NOTES A.FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY LANDSCAPE ARCHITECT. B.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION. C.FOR SEMI-IMPERVIOUS SOIL CONDITIONS, INSTALL ROOT BALL 4" ABOVE FINISHED GRADE. D.REMOVE WIRE AND NYLON TWINE FROM BALL AND CANOPY. E.SOAK ROOT BALL AND PLANTING PIT IMMEDIATELY AFTER INSTALLATION. F.STAKING IS REQUIRED FOR ALL TREES. G.REMOVE EXCESS SOIL FROM SITE AND DISPOSE OF IN A LEGAL MANNER. H.RESEED ALL DISTURBED AREAS. TAPER MULCH TO TRUNK; BASE OF TRUNK AND ROOT CROWN EXPOSED TOP OF ROOT BALL TO BE 2" ABOVE FINISHED GRADE; DO NOT PLACE ADDITIONAL SOIL ON TOP OF ROOT BALL MULCH PER SPECIFICATIONS THREE 1" X 2" X 18" WOOD STAKES WITH CENTERED 3 8" HOLE DRIVEN IN LINE WITH STRAP EQUALLY SPACED AROUND TREE FINISHED GRADE PREPARED PLANTING SOIL PER SPECIFICATIONS REMOVE TOP 1/3 OF BURLAP FROM B&B ROOT BALLS AND ANY NAILS, PINS, ETC. REMOVE TOP 1/3 OF WIRE BASKET WHERE PRESENT 6" SLIP KNOT WITH STOP KNOT 6" LARGER THAN TREE DIAMETER 3/4" NYLON STRAP 4" HIGH/6" WIDE MAX. BERM OUTSIDE OF ROOT BALL B&B OR CONTAINERIZED - SEE PLANT SCHEDULE FOR ROOT BALL SPECIFICATIONS SCARIFY SIDES OF HOLE TO 4" MIN. DEPTH COMPACT PLANTING SOIL BENEATH ROOT BALL REMOVE TYPICAL EXCESS SOIL FROM ROOT CROWN 6" MIN. TAPER MULCH TO TRUNK; BASE OF TRUNK AND ROOT CROWN EXPOSED TOP OF ROOT BALL TO BE 2" ABOVE FINISHED GRADE; DO NOT PLACE ADDITIONAL SOIL ON TOP OF ROOT BALL MULCH PER SPECIFICATIONS THREE 1" X 2" X 18" WOOD STAKES WITH CENTERED 3 8" HOLE DRIVEN IN LINE WITH STRAP EQUALLY SPACED AROUND TREE FINISHED GRADE PREPARED PLANTING SOIL PER SPECIFICATIONS REMOVE TOP 1/3 OF BURLAP FROM B&B ROOT BALLS AND ANY NAILS, PINS, ETC. REMOVE TOP 1/3 OF WIRE BASKET WHERE PRESENT 6" SLIP KNOT WITH STOP KNOT 6" LARGER THAN TREE DIAMETER 3/4" NYLON STRAP 4" HIGH/6" WIDE MAX. BERM OUTSIDE OF ROOT BALL B&B OR CONTAINERIZED - SEE PLANT SCHEDULE FOR ROOT BALL SPECIFICATIONS SCARIFY SIDES OF HOLE TO 4" MIN. DEPTH COMPACT PLANTING SOIL BENEATH ROOT BALL REMOVE TYPICAL EXCESS SOIL FROM ROOT CROWN NOTES A.FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY LANDSCAPE ARCHITECT. B.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION. C.FOR SEMI-IMPERVIOUS SOIL CONDITIONS, INSTALL ROOT BALL 4" ABOVE FINISHED GRADE. D.REMOVE WIRE AND NYLON TWINE FROM BALL AND CANOPY. E.SOAK ROOT BALL AND PLANTING PIT IMMEDIATELY AFTER INSTALLATION. F.STAKING IS REQUIRED FOR ALL TREES. G.REMOVE EXCESS SOIL FROM SITE AND DISPOSE OF IN A LEGAL MANNER. H.RESEED ALL DISTURBED AREAS. NOTE: APPLY HARDWOOD MULCH IN A 6' DIAMETER RING WHERE TREE PLANTINGS OCCUR IN GRASS AREAS. 6' DIAMETER HARDWOOD MULCH PER SPECIFICATIONS SEE TREE PLANTING DETAIL FOR TREE STAKING SMOOTH CONTINUOUSLY EDGED BED TREE - SEE LANDSCAPE PLAN NOT TO SCALE2PLANT MASSING AND GROUNDCOVER NOT TO SCALE3SHRUB PLANTING NOT TO SCALE4MULCH RING NOT TO SCALE5EVERGREEN TREE NOT TO SCALE6LARGE MATURING TREE NOT TO SCALE7PLANTING SCHEDULE ADDITIONAL QTY DESCRIPTION REMARKS SOD TIFWAY 419 BERMUDA SOD SOD MUST NOT BE GROWN IN SOIL THAT HAS AN IMPERMEABLE LAYER WHILE AT SOD NURSERY 514.18349.00 08.07.2024 NORTHCHASE BRANCH LIBRARY NO.REASON DATE TRC FINAL APPROVAL Jerry Guerrier, AIA Charlie Hagen-Cazés, AIA R. Florence, PLA, M. Sweitzer 2024 4400 Northchase Parkway NE Wilmington NC 28405 c PROJECT MANAGER DESIGN TEAM PRINCIPAL IN CHARGE PROJECT TEAM REVISIONS PROJECT NAME SHEET TITLE PROJECT NO. SHEET NUMBER ISSUE FOR ISSUE DATE PREPARED FROM INFORMATION PROVIDED BY THE CONTRACTOR CONSTRUCTING THE PROJECT. DESIGNER DOES NOT WARRANT THE INFORMATION HEREIN TO BE COMPLETE, ACCURATE, OR ALL ENCOMPASSING. RECORD DRAWINGS w w w . l i t t l e o n l i n e . c o m This drawing and the design shown are the property of Little Diversified Architectural Consulting. The reproduction, copying or other use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. 410 Blackwell Street, Suite 10 Durham, NC 27701 (919) 474-2500 Little L301 LANDSCAPE DETAILS VARIES SEE PLAN NOTES: 1.FOR NEW PLANTING AREAS, REMOVE ALL PAVEMENT, GRAVEL SUB-BASE AND CONSTRUCTION DEBRIS BEFORE AMENDING SOIL AND PLANTING TREES. 2.PLANTING PIT SOIL MIXTURE: AMEND EXISTING SOIL WITH 3 PARTS TOPSOIL, 1 PART COARSE SAND AND 1 PART COMPOST/PEAT MOSS. 3.REFER TO LANDSCAPE SPECIFICATIONS FOR TOPSOIL/PLANTING MIX SPECIFICATIONS. PLANT PER PLAN CROWN 10" -12" M I N . CRO W N 10" -1 2 " M I N . MULCH OR SEED PER PLANS AMEND EXISTING SOIL PER SPECIFICATIONS NOT TO SCALE1PARKING LOT ISLAND TREE BASE OF TRUNK AND ROOT CROWN EXPOSED 6" BASE OF TRUNK AND ROOT CROWN EXPOSED CODE BOTANICAL / COMMON NAME ROOT CAL QTY LG. DECIDUOUS NYSY NYSSA SYLVATICA / TUPELO B&B 2"-2.5"12 QUNU QUERCUS NUTTALLII / NUTTALL OAK B&B 2"-2.5" MIN 14 TADI TAXODIUM DISTICHUM / BALD CYPRESS B&B 2"-2.5"13 LG. EVERGREEN JUVS JUNIPERUS VIRGINIANA / EASTERN REDCEDAR 15 GAL.28 JUVI JUNIPERUS VIRGINIANA / EASTERN REDCEDAR B&B 2"-2.5"51 PIPA PINUS PALUSTRIS / LONGLEAF PINE B&B 2"-2.5"22 QUVI QUERCUS VIRGINIANA / SOUTHERN LIVE OAK B&B 2"-2.5" MIN 9 UNDERSTORY CHVI CHIONANTHUS VIRGINICUS / WHITE FRINGETREE B&B 2"-2.5"4 CODE BOTANICAL / COMMON NAME CONT SIZE SPACING QTY DECIDUOUS SHRUBS ILVE ILEX VERTICILLATA / WINTERBERRY 1 GAL.36" o.c.9 ILVM ILEX VERTICILLATA 'MALE' / MALE WINTERBERRY 1 GAL.36" o.c.2 ITVI ITEA VIRGINICA / VIRGINIA SWEETSPIRE 1 GAL.36" o.c.7 EVERGREEN SHRUBS DARA DANAE RACEMOSA / POET'S LAUREL 1 GAL.48" o.c.17 ILGL ILEX GLABRA 'SHAMROCK' / SHAMROCK INKBERRY HOLLY 1 GAL.36" o.c.16 ILVO ILEX VOMITORIA / YAUPON HOLLY 1 GAL.60" o.c.76 JUSM JUNIPERUS CONFERTA 'SILVER MIST' / SILVER MIST SHORE JUNIPER 1 GAL.30" o.c.154 MOCA MORELLA CAROLINIENSIS / BAYBERRY 1 GAL.60" o.c.44 SAMI SABAL MINOR / DWARF PALMETTO 1 GAL.120" o.c.7 YUFI YUCCA FILAMENTOSA / ADAM'S NEEDLE 1 GAL.36" o.c.58 YUEX YUCCA FILAMENTOSA 'EXCALIBUR' / EXCALIBUR ADAM'S NEEDLE 1 GAL.36" o.c.4 GRASSES MUPC MUHLENBERGIA CAPILLARIS 'PINK CLOUD' / PINK CLOUD PINK MUHLY GRASS 1 GAL.36" o.c.414 MUWC MUHLENBERGIA SERICEA 'WHITE CLOUD' / WHITE CLOUD DUNE HAIRGRASS 1 GAL.36" o.c.14 PAHM PANICUM VIRGATUM 'HEAVY METAL' / HEAVY METAL SWITCH GRASS 1 GAL.36" o.c.244 SSSO SCHIZACHYRIUM SCOPARIUM 'STANDING OVATION' / STANDING OVATION LITTLE BLUESTEM 1 GAL.18" o.c.460 SPHE SPOROBOLUS HETEROLEPIS / PRAIRIE DROPSEED 1 GAL.42" o.c.77 PERENNIALS ACMI ACHILLEA MILLEFOLIUM / COMMON YARROW 1 GAL.36" o.c.15 ASCI ASCLEPIAS INCARNATA 'CINDERELLA' / CINDERELLA SWAMP MILKWEED 1 GAL.24" o.c.7 ASTU ASCLEPIAS TUBEROSA / BUTTERFLY MILKWEED 1 GAL.24" o.c.18 COCA CONRADINA CANESCENS / FALSE ROSEMARY 1 GAL.36" o.c.90 IRVE IRIS VERSICOLOR / BLUE FLAG 1 GAL.24" o.c.41 LOCA LOBELIA CARDINALIS / CARDINAL FLOWER 1 GAL.24" o.c.17 RUFU RUDBECKIA FULGIDA / CONEFLOWER 1 GAL.24" o.c.13 SOFI SOLIDAGO RUGOSA 'FIREWORKS' / FIREWORKS WRINKLELEAF GOLDENROD 1 GAL.36" o.c.11 SEDGES CARR CAREX BUCHANANII 'RED ROOSTER' / RED ROOSTER LEATHER LEAF SEDGE 1 GAL.18" o.c.13 CABL CAREX FLACCA 'BLUE ZINGER' / BLUE ZINGER SEDGE PLUG 12" o.c.243 GROUND COVERS BRMU BROWN HARWOOD MULCH / NATURAL HARDWOOD MULCH MULCH 5,001 SF PLANT SCHEDULE NCHASE