HomeMy WebLinkAbout8-21-2024 TRC Agenda Full1
TECHNICAL REVIEW COMMITTEE AGENDA
August 21st, 2024
New Hanover County’s Technical Review Committee (TRC) will meet Wednesday, August 21, 2024
at 2:00 p.m. to discuss the below items.
PLEASE NOTE:
This meeting will be conducted remotely via teleconference. Interested parties can contact the Planning
and Land Use Department at 910-798-7165 for more information.
Item 1: HWY 421 Business Park – Commercial Site Plan – SITECN-24-000033
Request by McKinley Dull, Manager of Seamist Properties and McKinley Building
(kdull@mckinleybuilding.com) for a 69,000 sf business park facility. The site is located at 4601 US Hwy
421 N and is 4.8 acres, zoned I-2. The engineer is T Jason Clark with Norris & Tunstall
(jclark@ntengineers.com). The case planner is Amy Doss (adoss@nhcgov.com, 910-798-7571)
Item 2: Pierson’s Point – Major Subdivision Preliminary Plan – SUBPP-24-0008
Request by Jody Waino with the Wilmington Realtor’s Foundation (jodyw@kw.com) for a 48 townhome
subdivision. The site is located at 6221 Carolina Beach Road and is 6.13 acres, zoned (CZD) R-5. The
engineer is Luke Menius with Stroud Engineering (lmenius@stroudengineer.com). The case planner is
Zach Dickerson (zdickerson@nhcgov.com, 910-798-7450)
HWY 421 Business Park – Commercial Site Plan – TRC Review
Page | 1
To: Jason Clark, PE – Norris & Tunstall Consulting Engineers, PC (jclark@ntengineers.com)
From: Amy Doss
Current Planner
Date: August 21, 2023
Energov #: SITECN-24-000031
PID: R02400-001-065-000
Subject: HWY 421 Business Park – 4601 US HWY 421 N. – Commercial Site Plan – TRC Review
The following comments have been received for the August 21, 2023, TRC meeting.
Please note: following the TRC meeting, a revised site plan addressing each of the below items must be
resubmitted prior to receiving approval.
Planning, Amy Doss 910-798-7571
Please update the plan with the following general corrections:
1. Zoning: I-2
2. Building Height: 40’, site plan in compliance.
3. Uses (1):
a. The defined use is Warehouse: The storing of goods, wares, and merchandise within an
enclosed building, whether for the owners or others. There is little on-site sales activity
with the customer present. Uses include: cold storage facilities (including frozen food
lockers); distribution warehouses (used primarily for temporary storage pending
distribution in response to customer orders); storage warehouses (used for storage by
retail stores such as furniture and appliance stores); warehouse storerooms; or similar
uses.
4. General Comments:
a. Please ensure to note: Elevations must be tied to North American Vertical Datum of 1988
(NAVD 88) and horizontal coordinates must be tied to the North Carolina Grid System.
5. Landscape notes:
a. Please provide a detailed landscape plan schedule illustrating the requirements for interior
landscaping, street yards, foundation planting, and buffers have been met.
6. Tree Retention:
a. Tree removal permit has already been executed.
7. Please be aware that no building permit will be issued until NCDOT has issued the Driveway Permit
approval.
HWY 421 Business Park – Commercial Site Plan – TRC Review
Page | 2
8. Parking/Loading:
a. Parking requirements are met.
9. Lighting:
a. Before the building permit can be issued, a lighting plan must be provided to illustrate that
street lighting, all exterior lighting, and indoor lighting visible from outside shall be
designed and located so that the maximum illumination measured in foot candles at
ground level at a residential lot line does not surpass 0.5, UDO Section 5.5. Please refer to
Table 5.5.4.B of the UDO for additional standards. Provide documentation from the lighting
provider stating they will provide a lighting plan to comply with the County’s UDO
standards as stated above. Note that no lighting is proposed.
Fire Services, Ray Griswold 910-798-7448
1. Fire Finals required.
2. Sprinkler & Fire Alarm permits required.
3. Add additional fire hydrant in median area between the building & dumpster pad. steamer
connection pointed towards the south roadway.
4. Will high rack storage be used? Build towards those fire protection standards if applicable.
5. A fire hydrant shall be located within 100 feet of the FDC. Need to show on plans FDC location.
6. A section 510 survey is required for Emergency First Responder Radio Coverage.
7. Knox Boxes required. Will decide locations when building is approved and during construction
phase.
8. Provide an Engineered Fire Flow Analysis.
9. A second means of access is required for buildings over 62,000 sq. feet and exceeding 30 feet in
height. What is the proposed height of this building?
10. Please resubmit for item #3 & #9.
NHC Engineering, Galen Jamison 910-798-7072
1. A land disturbing issued by the County is required for this project. Please digitally submit the
permit application documentation with requisite review fees for County issued permit directly to
gjamison@nhcgov.com. Application and forms can be found at
https://www.nhcgov.com/249/Sediment-Erosion-Control
2. A County stormwater permit revision to STMW-22-0055 is required for this project. Please
digitally submit the permit applications documentation with requisite review fees to the COAST
online permit portal (https://newhanovercountync-
energovpub.tylerhost.net/apps/selfservice#/home). Applicable forms can be found at
https://www.nhcgov.com/251/Stormwater however the application form is not required as the
information will be gathered by the COAST portal.
3. County stormwater permit STMW-22-0055 allocates 176,739 SF of impervious area to parcel B1
but the proposed impervious area is 183,695 SF. Please ensure the allocation in the existing permit
and the proposed are inline when submitted for permitting.
HWY 421 Business Park – Commercial Site Plan – TRC Review
Page | 3
4. Please contact the State for the stormwater permit modification requirements.
Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620
CFPUA TRC Comments provided are preliminary comments only.
1. Utility Plan review required by CFPUA. CFPUA is moving toward becoming paperless. When
ready to submit plan review package, upload all documents to
https://www.cfpua.org/FormCenter/Engineering-3/Engineering-Plan-Review-103.
2. CFPUA water available via mainline extension.
3. CFPUA sewer will be available via a forcemain to forcemain connection.
4. Capacity is dependent on the analysis of the pipe collection system (gravity and force mains).
5. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE Application
Form and a Preliminary Plan, this determination does not guarantee capacity.
6. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the plans
meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the Authority.
NCDOT, Nick Drees/Mike Frank, 910-398-9100
See appendix
Environmental Health, Dustin Fenske 910-798-6732
1. Site plan reflects connection to CFPUA water and sewer.
2. Environmental Health has no records of any well or septic systems located on this property or
surrounding properties.
WMPO, Abby Lorenzo 910-341-7890
1. Comments forthcoming.
Addressing, Katherine May 910-798-7443
1. Suites will need individual address. They should be displayed clearly on each entrance and must
match our records.
2. Please contact me for address assignments after TRC approval. kmay@nhcgov.com
HWY 421 Business Park – Commercial Site Plan – TRC Review
Page | 4
Comments not received at this time from:
Emergency Services & E911, Steven Still
NCDEQ, Chad Coburn
New Hanover Soil & Water, Dru Harrison
NCDEMLR, Dan Sams
DCM, Tanya Pietila
FLYILM, Dick Granseur
New Hanover County Schools, Laura Severt
USACE, Brad Shaver
STATE OF NORTH CAROLINA
DEPARTMENT OF TRANSPORTATION
ROY COOPER J.R. “JOEY” HOPKINS
GOVERNOR SECRETARY
Mailing Address:
NC DEPARTMENT OF TRANSPORTATION
DISTRICT 3 ENGINEER’S OFFICE
5911 OLEANDER DRIVE, SUITE 101
WILMINGTON, NC 28403
04-11-03 COURIER
Telephone: 910-398-9100
Customer Service: 1-877-368-4968
Website: ncdot.gov
Location:
5911 OLEANDER DRIVE, SUITE 101
WILMINGTON, NC 28403
Memorandum
To: New Hanover County Technical Review Committee
Date: August 6, 2024
Subject: US 421 Business Park Northwest – 4601 N US Hwy 421
________________________________________________________________________
These are preliminary comments and are based on the plans as submitted for the proposed
site. They are subject to further review upon receipt of any additional information.
Subsequently, additional comments and/or requirements may be necessary for this site.
General Comments:
NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT
Online Portal.https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx
NCDOT Driveway Permit:
An NCDOT Driveway Permit is required. Submit plans in accordance with pages 14 and
15 of the Policy on Street and Driveway Access to North Carolina Highways to include
access locations within 500’ of the proposed access on both sides of the State Road.
Submit to the local NCDOT District Engineer’s Office.
x Reference Driveway Permit # D033-065-23-0021 in your cover letter as this will
be a revision to the original permit.
x Refer to the NCDOT checklist (included) for required documents and site plan
information.
NCDOT Encroachment Agreement:
An NCDOT Encroachment Agreement is required for any utility connections or
installations within the NCDOT right-of-way (form 16.6).
x It is recommended that you reach out to the NCDOT District Office prior to
submitting plans to avoid a redesign of the proposed utilities.
x Refer to the NCDOT UAM Manual and the NCDOT encroachment checklist for
required documents and site plan information.
Mailing Address:
NC DEPARTMENT OF TRANSPORTATION
DISTRICT 3 ENGINEER’S OFFICE
5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403
04-11-03 COURIER
Telephone: 910-398-9100
Customer Service: 1-877-368-4968
Website: ncdot.gov
Location:
5911 OLEANDER DRIVE, SUITE 101
WILMINGTON, NC 28403
Site Plan Comments:
Include/update the NCDOT Standard Drawings (2024) that are applicable to the
development.
Sight Triangles and Sight Distance:
x Show and label the 10’ X 70’ NCDOT sight triangles.
o No obstructions shall be placed within the NCDOT sight triangles.
x Show and label the stopping sight distance.
o No obstructions shall be placed within the stopping sight distance.
You can coordinate with the district office with any questions 910-398-9100.
NCDOT | Division 3 | District 3 Project Name:_____________________________ Date:_______________
Applicant
Checklist NCDOT
Checklist
Driveway Application Process and Site Plan Requirements
ALL APPLICATIONS SHALL BE ACCOMPANIED BY COMPLETE AND DETAILED SITE PLANS THAT ADHERE TO THE POLICIES LISTED IN THE POLICY ON STREET AND
DRIVEWAY ACCESS TO NORTH CAROLINA HIGHWAYS AND THIS DOCUMENT. FAILURE TO ADHERE TO THESE POLICIES WILL RESULT IN THE RETURN OF THE
APPLICATION TO THE APPLICANT FOR REVISION.
***THE NCDOT WILL NOT BEGIN THE REVIEW PROCESS ON INCOMPLETE APPLICATIONS***
Electronic Pre-Submittals
In an effort to save time and resources, we are happy to provide an initial assessment of a driveway permit submittal’s plans via email to
identify any major issues up front. This initial assessment can be followed up with a submittal ŽĨŽŶĞĚŝŐŝƚĂůĐŽƉLJŽĨƚŚĞƉůĂŶƐ along with all
other required documents.
ůůWĞƌŵŝƚĂƉƉůŝĐĂƚŝŽŶƐƐŚĂůůďĞƐƵďŵŝƚƚĞĚƚŚƌŽƵŐŚƚŚĞŽŶůŝŶĞƉŽƌƚĂůŚƚƚƉƐ͗ͬͬĐŽŶŶĞĐƚ͘ŶĐĚŽƚ͘ŐŽǀͬƐŝƚĞͬWĞƌŵŝƚƐͬWĂŐĞƐͬĚĞĨĂƵůƚ͘ĂƐƉdž
/ŶƚŚĞŶŽƚŝĨLJĞŵĂŝůƐĞĐƚŝŽŶŽĨƚŚĞƉŽƌƚĂůĂƉƉůŝĐĂƚŝŽŶƉůĞĂƐĞŝŶĐůƵĚĞƚŚĞŝƐƚƌŝĐƚKĨĨŝĐĞĞŵĂŝů;ŝǀϯŝƐƚϯΛŶĐĚŽƚ͘ŐŽǀͿ͘^ĞĞƚŚĞůĂƐƚƉĂŐĞƐĨŽƌĨƵƌƚŚĞƌŝŶƐƚƌƵĐƚŝŽŶ͘
Online resources:
x NCDOT Policy on Street and Driveway Access to North Carolina Highways:
https://connect.ncdot.gov/projects/Roadway/RoadwayDesignAdministrativeDocuments/Policy%20on%20Street%20an
d%20Driveway%20Access.pdf
x NCDOT Policies and Procedures for Accommodating Utilities on Highway Rights of Way:
https://connect.ncdot.gov/municipalities/Utilities/Pages/UtilitiesManuals.aspx
x Electronic Forms Database:
https://connect.ncdot.gov/Pages/default.aspx
1)
Ă͘Cover >etter
Include contact information for applicant and engineer, including email address, mailing address, and phone
number. Include ƚŚĞƉĂƌĐĞůŶƵŵďĞƌ;ƐͿ͕description of all phases of the development and future land uses to be
served by the permit,ĂŶĚa description of the adjoining land owned or controlled by the applicant.
ď͘NCDOT Street and Driveway Access Permit Application (form downloadable via link below)
https://connect.ncdot.gov/resources/BusinessForms/TEB-65-04.doc
Đ͘$50.00 /nspection &eeWĞƌĐĐĞƐƐWŽŝŶƚ
Attach to Permit Application form (not applicable for municipalities, churches, and schools)
Ě͘NPDES Stormwater Permit Compliance Certification (form downloadable via link below)
https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/NPDESstatement.doc
Ğ͘Verification of Compliance with Environmental Regulations (form downloadable via link below)
https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/VCER-1.pdf
Ĩ͘Site Plans (to include the “Master Plan” of a tract even if only a small portion is being developed first)Additional
site plan requirement details can be found in section 2 of this document.
Ő͘ĞƐŝŐŶ PlanZĞƋƵŝƌĞŵĞŶƚƐ ĨŽƌƉƌŽũĞĐƚƐŝŶǀŽůǀŝŶŐƌŽĂĚǁĂLJŝŵƉƌŽǀĞŵĞŶƚƐ
If roadway improvements are required as part of the permit, ƚŚĞŶroadway plans͕ƉĂǀĞŵĞŶƚŵĂƌŬŝŶŐƉůĂŶƐ͕
ƐŝŐŶŝŶŐƉůĂŶƐ͕ĂŶĚƚƌĂĨĨŝĐĐŽŶƚƌŽůƉůĂŶƐǁŝůůďĞƌĞƋƵŝƌĞĚͲ^ĞĞ^ĞĐƚŝŽŶϲĨŽƌŵŽƌĞŝŶĨŽƌŵĂƚŝŽŶ
Y N n/a
Engineering Studies
The applicant may be required by the District Engineer to submit studies based on, but not limited to, the parameters outlined
herein. If study requirements of the local government agency are more restrictive than the NCDOT requirements, then local
government requirements will govern. However, this does not imply that the NCDOT is obligated to approve entrance designs
that are too constrictive to allow smooth and safe traffic flow. All studies including, but not limited to, Traffic Impact Analyses
(TIA), traffic signal studies, and drainage studies, must be prepared under the direct charge of and sealed by a North Carolina
licensed Professional Engineer.
Section 1: Requi
red Documents
|Required documents to accompany all /ŶŝƚŝĂůƌŝǀĞway Application Submittals
WůĞĂƐĞŶŽƚĞƚŚĂƚƚŚĞƐĞĂƌĞƚŚĞŵŝŶŝŵƵŵƌĞƋƵŝƌĞŵĞŶƚƐŽĨĂůůĚƌŝǀĞǁĂLJƉĞƌŵŝƚĂƉƉůŝĐĂƚŝŽŶƐ͘
ůůƌĞƋƵŝƌĞĚĚŽĐƵŵĞŶƚĂƚŝŽŶƐŚĂůůďĞƐƵďŵŝƚƚĞĚƚŚƌŽƵŐŚƚŚĞŽŶůŝŶĞƉŽƌƚĂůĂƐW&ĨŝůĞƐ͕ǁŝƚŚƚŚĞĞdžĐĞƉƚŝŽŶŽĨƚŚĞ
WĞƌĨŽƌŵĂŶĐĞĂŶĚ/ŶĚĞŵŶŝƚLJŽŶĚĂŶĚƚŚĞΨϱϬ/ŶƐƉĞĐƚŝŽŶ&ĞĞ;ƐͿ͕ƚŚĞƐĞƐŚŽƵůĚďĞŵĂŝůĞĚŽƌĚĞůŝǀĞƌĞĚƚŽϱϱϬϭ
ĂƌďĂĚŽƐůǀĚ͕ĂƐƚůĞ,ĂLJŶĞ͕EϮϴϰϮϵ͘
If a Traffic Impact Analysis and/or roadway improvements are deemed necessary as a condition of the permit͕ƚŚĞƌĞ
ŵĂLJďĞĂĚĚŝƚŝŽŶĂůƐƵďŵŝƚƚĂůŵĂƚĞƌŝĂůƐƌĞƋƵŝƌĞĚ͘
State of North Carolina | Department of Transportation | Division 3 | District 3
%DUEDGRV%OYG,&DVWOH+D\QH, NC 284
Form Updated/20(910) T NCDOT Permit #___________________
Y N n/a
Section 1: Required Documents (continued)
2)Required documents to accompany all Driveway Applications PRIOR TO FINAL APPROVAL
Ă͘Site Plans
Kne (1) digital copy (PDF) unless otherwise requested bythe District Office. Additional site plan requirement
details can be found in section 2 of this document.
ď͘Performance and Indemnity Bond/ŶĨŽƌŵĂƚŝŽŶͬFormƐ
^ĞĞůĂƐƚƉĂŐĞŽĨĚŽĐƵŵĞŶƚĨŽƌďŽŶĚŝŶĨŽƌŵĂƚŝŽŶĂŶĚĨŽƌŵƐ
Đ͘Performance and Indemnity Bond Amount
100% of ƚŚĞĐŽƐƚŽĨƚŚĞǁŽƌŬwithin NCDOT Zight-of-tay;ZͬtͿ based on ƚŚĞattached estimatedetermined by
ƚŚĞĂƉƉůŝĐĂŶƚΖƐĞŶŐŝŶĞĞƌĂŶĚĂƉƉƌŽǀĞĚďLJƚŚĞDistrict Engineer. ŽŶĚŚŽůĚůĞƚƚĞƌƌĞƋƵŝƌĞĚĨŽƌĨŽƌŵƵŶŝĐŝƉĂůŝƚŝĞƐ͕
ĐŚƵƌĐŚĞƐ͕ĂŶĚƐĐŚŽŽůƐ͘See pages 101-105 in the Policies and ProceduresforAccommodatingUtilities on Highway
Rights of Way for acceptable bond types
Ě͘Radius Encroachment Letter (if applicable)
If driveway radius encroaches on the frontage of an adjacent property, a Radius Encroachment will be required
Ğ͘Hold Harmless Letter (if applicable)
If the Wermit is within ƚŚĞůŝŵŝƚƐŽĨĂŶ active NCDOT project, a Hold Harmless letter from the NCDOT contractorwill
be required͘/ĨƚŚĞƉƌŽũĞĐƚŝƐŝŶƉƌĞĐŽŶƐƚƌƵĐƚŝŽŶ͕ĐŽŽƌĚŝŶĂƚĞǁŝƚŚƚŚĞĞƉĂƌƚŵĞŶƚΖƐWƌŽũĞĐƚĞǀĞůŽƉŵĞŶƚhŶŝƚ
Section 2: General Site Plan Requirements | All site plans shall include and show, at a minimum, the items listed below
Page numbers reference the NCDOT Policy on Street and Driveway Access to North Carolina Highways
ϭͿ Drawn to a scale of 20, 30, 40, or 50 feet per inch and the scale shall be shown
ϮͿ North arrow, vicinity map, date of plan, and date of most-recent revision if applicable
ϯͿ Contact information of applicant and engineer, including mailing address, phone number, and email address
ϰͿ Show Zͬt lines, highway control of access, and property lines
ϱͿ All existing utilities (including handholes) and easements
ϲͿ Rͬt width
ϳͿ Existing posted speed limit(s) and design speed limit(s)
ϴͿ Show all property lines, intersections, signals, signal loops, railroads, or crossovers within 500’ in all directions of
the property lines of the proposed development
ϵͿ Show location of sidewalks, crosswalks, greenways, multi-use paths, curb ramps, railroads, bus stops, and any
other relevant transportation facilities in the development area
ϭϬͿ Include a plan sheet showing full site build-out and land use
ϭϭͿ Buildings shown with “gross leasable area”
ϭϮͿ Width of property frontage
ϭϯͿ Distance from Rͬt to buildings and gasoline service islands
ϭϰͿ Distance from Rͬt to existing/proposed ĚŐĞŽĨWĂǀĞŵĞŶƚ;KWͿ (pages 32 & 34)
ϭϱͿ All streams, bridges, retaining walls, signs, or other fixed objects such as trees, utility poles, traffic signals, etc.
Section 3: Driveway Plan Requirements
|
All driveway plans shall include and show, at a minimum, the items listed below
ϭͿ WƌŽǀŝĚĞĐŽŵƉƌĞŚĞŶƐŝǀĞƐƵƌǀĞLJǁŝƚŚŝŶƚŚĞĞdžŝƐƚŝŶŐZͬtŽŶďŽƚŚƐŝĚĞƐŽĨƚŚĞƌŽĂĚĨŽƌĂĚŝƐƚĂŶĐĞŽĨϱϬϬ͛ŝŶĂůů
ĚŝƌĞĐƚŝŽŶƐĨƌŽŵƚŚĞĚĞǀĞůŽƉŵĞŶƚ͛ƐƉƌŽƉĞƌƚLJůŝŶĞƐ͘WƌŽǀŝĚĞĂĚĚŝƚŝŽŶĂůŚLJĚƌĂƵůŝĐƐƵƌǀĞLJĚĂƚĂƚŽƚŚĞŶĞĂƌĞƐƚƐƚŽƌŵ
ǁĂƚĞƌŝŶůĞƚͬŽƵƚůĞƚŝŶĐůƵĚŝŶŐĚŝƚĐŚůŝŶĞƐĂŶĚƐƚŽƌŵǁĂƚĞƌƉŝƉĞƐ͕ŝĨůŽĐĂƚĞĚŽƵƚƐŝĚĞŽĨƚŚĞϱϬϬΖĚŝƐƚĂŶĐĞ͘
ϮͿ Lane configurations and widths of all existing and proposed driveways, roadways, and adjacent roadways
ϯͿ All driveway widths (2-way: 20’ minimum, 36’ maximum | 1-way: 12’ minimum, 24’ maximumͮǁŝƚŚŝƐůĂŶĚ͗ϭϰΖ
ŝŶŐƌĞƐƐ͕ϭϴΖĞŐƌĞƐƐ) (pageƐϱϬΘϳϳ)
ϰͿ ƌŝǀĞǁĂLJWƌŽĨŝůĞͲ/ŶƐŚŽƵůĚĞƌƐĞĐƚŝŽŶƐ͕ŵaintain minimum 2% fall from edge of travel way for required
shoulder width ĚŝƐƚĂŶĐĞWƌŝŵĂƌLJ͗ϴ͛ŵŝŶŝŵƵŵͮ^ĞĐŽŶĚĂƌLJ͗ϲ͛ŵŝŶŝŵƵŵ
ϱͿ All existing and/or proposed driveway radii (20’ minimum, 50’ maximum, 30’ typical) (pages 34 & 51)
In curb and gutter sections, use City of Wilmington flare (SD 3-03.3)Ͳ;ƐĞĞĂƚƚĂĐŚĞĚͿ
In shoulder sections, show grades at the KW and centerline
ϲͿ No curbing is allowed within NCDOT RͬW along shoulder sections except as part of a driveway island(page 31)
ϳͿ Driveway angles of approach to existing roadway (90° preferred, 75°-90° required for 2-way driveways, 45°-90°
allowed for right-in/right-out on a case-by-case basis) (page 51)
ϴͿ Driveway Wrofile (pages 42- 43)
Y N n/a Y N n/a
පප පපප ප
Y N n/a Y N n/a
Y N n/a Y N n/a
Section 3: Driveway Plan Requirements (continued)
ϵͿ Driveway Pavement Cross Section (to be in place from KW to edge of RͬW)
Asphalt: 8” ABC stone and 1.5” S9.5
Concrete: 6” of concrete
ϭϬͿ Driveway Offset (driveway KW to property line; page 75): Minimum: 20’
ϭϭ)Corner Clearance (radius point to radius point; page 52) Minimum: 50’ Desirable: 100’ or DƵŶŝĐŝƉĂů std.
ϭϮͿ Minimum 10’x70’ sight triangles at driveways (measured from and along the Zͬt line) (page 31)
ϭϯͿ Sight Distance (ůength of sight-distance in both directions shown for each driveway; pages 27-29)
ϭϰͿ Driveways should be aligned with existing opposing driveways or correct offset should be provided (pages 40-41)
ϭϱͿ Distance between driveways being requested (if applicable; page 51)
ϭϲͿ Minimum internal storage areasǁŝƚŚƐƉĞĐŝĨŝĞĚƋƵĞƵĞƐ (pages 31-33)
ϭϳͿ Minimum protected driveway stem(s) provided and indicated (pages 33-34)
ϭϴͿ Indicate any gated entrances (100’ minimum setback from RͬW required)ͲƚƌĂĨĨŝĐƋƵĞƵŝŶŐƐƚƵĚLJŵĂLJďĞƌĞƋƵŝƌĞĚ
|
Section ϲ: Roadway
Plan Requirements
If off-site improvements are required, roadway plans shall show, at a minimum, the items below
ϭͿ Full width typical sections must be shown (paved shoulders to match the typical section of the adjacent roadway)
ϮͿ Minimum Asphalt Typical Section (for turn lanes and/or paved shoulders)
Adjacent recently-completed or upcoming TIP projects w/ different typical sections may supersede those below
x Primary Routes (US & NC) and Secondary Routes with ŶŶƵĂůǀĞƌĂŐĞĂŝůLJdƌĂĨĨŝĐ;AADTͿшϭϬ,000
5͘ϱ” B25.0, 3” I19.0, ϭ͘ϱ” S9.5; any overlay of existing pavement is to be a minimum of 1.5” S9.5
x Secondary Routes with AADT<ϭϬ,000
5͘ϱ” B25.0, ϭ͘ϱ” Sϵ͘ϱ; any overlay of existing pavement is to be a minimum of 1.5” Sϵ͘ϱ
ϯͿ Pavement overlay is required if modification of existing pavement markings and/or lanes is necessary
The grinding of pavement markings will not be allowed
ϰͿ Shoulder Widths (Paved + Unpaved)WƌŝŵĂƌLJ͗ϴ͛ŵŝŶŝŵƵŵͮ^ĞĐŽŶĚĂƌLJ͗ϲ͛ŵŝŶŝŵƵŵ
ϱͿ ŝƚĐŚ^ůŽƉĞƐͲĨƌŽŶƚĂŶĚďĂĐŬƐůŽƉĞƐͲŵŝŶŝŵƵŵϯ͗ϭŽƌĨůĂƚƚĞƌ
ϲͿ Indicate existing roadway grade
ϳͿ All taper lengths and deceleration lengths should be appropriately designed for the given design speed (page78)
ϴͿ All turn lanes should be designed according to the Driveway Manual and Roadway Standard Drawings (page 79)
See 1205.04 Sheets 1 & 2 and 1205.05 Sheet 1 of the Roadway Standard Drawings for details
ϵͿ Pavement markingĂŶĚƐŝŐŶŝŶŐ planƐ ĂƌĞƌĞƋƵŝƌĞĚͲplans must be approved by Division Traffic Services
ϭϬͿ dƌĂĨĨŝĐĐŽŶƚƌŽůƉůĂŶƐĂƌĞƌĞƋƵŝƌĞĚͲĞƚĂŝůĞĚƉŚĂƐŝŶŐƉůĂŶƐŵĂLJďĞƌĞƋƵŝƌĞĚďĂƐĞĚŽŶƉƌŽũĞĐƚƚLJƉĞĂŶĚůŽĐĂƚŝŽŶ
ϭϭͿ EĞǁĂŶĚͬŽƌƌĞǀŝƐĞĚƐŝŐŶĂůƉůĂŶƐŵƵƐƚďĞŝŶĐůƵĚĞĚĨŽƌŶĞǁŝŶƐƚĂůůĂƚŝŽŶƐĂŶĚŝĨƐŝŐŶĂůŵŽĚŝĨŝĐĂƚŝŽŶƐĂƌĞƌĞƋƵŝƌĞĚ
ůůsignal plans must be reviewed and approved by Division Traffic Services and the Signal Design Unit. ATraffic
Agreement must be completed to facilitate the review. Contact Division Traffic Services at (910) 341-ϮϮϬϬ.
|
Section ϰ: Drainag e Requirements
All drainage features on NCDOT Right-of-Way shall adhere to, at a minimum, the items listed below
Section ϱ: Internal Circ ulation Requirements
|All internal circulation details shall adhere to, at a minimum, the items listed below
ϭͿ Interior driveway channelization stems
Minimum 100’ from the RKW or at the discretion of the District Engineer
ϮͿ Traffic flow pattern
ϯͿ Traffic control devices
ϰͿ Pavement Markings
Y N n/a Y N n /a
Y N n/a Y N n/a
Y N n/a Y N n/a
Y N n/a Y N n/a
ϭͿ Pipe Cover Minimums (measured from top of pipe to subgrade)
High Density Polyethylene (HDPE): Ϯϰ” | Corrugated Aluminum (CAP): 12” | Reinforced Concrete (RCP): 12”
ϮͿ WŝƉĞŶĚdƌĞĂƚŵĞŶƚ;ƐĞĞZŽĂĚǁĂLJĞƐŝŐŶDĂŶƵĂůϱͲϮϬ͕ͲϮͿ
WŝƉĞƐчϮϰΗŽŶŵƵůƚŝůĂŶĞŚŝŐŚǁĂLJƐƉŽƐƚĞĚĂďŽǀĞϰϱŵƉŚƌĞƋƵŝƌĞWĂƌĂůůĞůWŝƉĞŶĚ^ĞĐƚŝŽŶƐ^ĞĞϯϭϬ͘ϬϮĂŶĚ
ϯϭϬ͘ϬϰŽĨƚŚĞZŽĂĚǁĂLJ^ƚĂŶĚĂƌĚƌĂǁŝŶŐƐĨŽƌĚĞƚĂŝůƐ
WŝƉĞƐхϯϬΗŽŶŵƵůƚŝůĂŶĞŚŝŐŚǁĂLJƐƉŽƐƚĞĚĂďŽǀĞϰϱŵƉŚƌĞƋƵŝƌĞŐƵĂƌĚƌĂŝů
WŝƉĞƐшϯϲΗƌĞƋƵŝƌĞĂŶĞŶĚǁĂůůŽŶƚŚĞŝŶůĞƚĞŶĚ
ϯͿ ůůƉƌŽƉŽƐĞĚƌĂŝŶĂŐĞŝƐƚŽďĞƉƌŽǀŝĚĞĚŝŶƐŝĚĞĞdžŝƐƚŝŶŐZͬt͘KƚŚĞƌǁŝƐĞ͕ĂĚĚŝƚŝŽŶĂůZͬtŽƌĂƉĞƌŵĂŶĞŶƚůLJ
ĚĞĚŝĐĂƚĞĚĚƌĂŝŶĂŐĞĞĂƐĞŵĞŶƚǁŝůůďĞƌĞƋƵŝƌĞĚƚŽĂĐĐŽŵŵŽĚĂƚĞƚŚĞƉƌŽƉŽƐĞĚƉƌŽũĞĐƚĚƌĂŝŶĂŐĞ
ϰͿ All sizes, types, and invert elevations of existing/proposed pipes and drainage structures must be shown
;ƐĞĞ^ĞĐ͘ϯηϭĨŽƌƐƵƌǀĞLJƌĞƋƵŝƌĞŵĞŶƚƐͿ
ϱͿ Provide spot elevations along frontage of driveway (at EKW and centerline)
ϲͿ Provide grades and spot elevations for existing and proposed ditches
ϳͿ Show how drainage will be accommodated along property frontage
(District Engineer may require applicant to provide drainage calculations whĞŶǁĂƌƌĂŶƚĞĚͿ
&21'
8
,
7
&21'8
,
7
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
*5$
9
(
/
5
2
$
'
2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(
2+(
2+(
2+(
2+(
2+(
2+(
+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(
67(3$1&203$1<%.3*=21,1*,,1'8675,$/',675,&7&/$66,1',1'8675,$/
/$1'86(&+(0,&$/ $//,('
&0)
32:(5/,1(($6(0(17'%3*
&0)
)52176(7%$&.
,1*5(66(*5(66($6(0(170%3*
)52176(7%$&.
67:227(1&253%.3*=21,1*,,1'8675,$/',675,&7&/$66,1',1'8675,$//$1'86(&+(0,&$/ $//,('
86+,*+:$<
38%/,&5,*+72):$<
67:227(1&2535'%3*
6($%2$5'&2$67/,1(5$,/52$'
35,9$7(5:
,5)
727$//1
:
6
(
727$/
1
(
32:(5/,1(($6(0(17'%3*
87,/,7</,1(($6(0(17'%3*
,1*5(66(*5(66($6(0(170%3*
,1*5(66(*5(66($6(0(170%3*
'5$,1$*(($6(0(170%3*
'5$,1$*(($6(0(170%3*
///
,1'(;2)6+((76
6&$/(
86%86,1(663$5.1257+:(67
$7%86,1(663$5.
186+:<:,/0,1*7211&
&,9,/6,7('2&80(176
-8/<
/2&$7,210$3
6,7(
&200(5&,$/6,7(3/$1
7-$621 &/$5.
(1*,1((5
35(/
,
0
,
1
$
5
<
8*8*8*
:(//
&21
'
8
,
7
&21
'
8
,
7
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
2+(
8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*
*5$
9
(
/
5
2
$
'
::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
*0
)2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2
)2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2
2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(
2+(
2+(
2+(
2+(2+(
2+(
2+(
2+(
2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(
::::::::::::::::::
)0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0
5&35$::$7(5
::::::::::::::::::::::::::::::
/3)0
)0
:/
8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*
:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
)0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0
2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2 )2
8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*
5&35$::$7(5
:/
)0
/3)0/3)0
;;;;;;;;
;;
;
;
&/$66,1' ,1'8675,$//$1'86(&+(0,&$/ $//,('
&0)
32:(5/,1(($6(0(17
'%3*
&0)
',7&+
',7&+
)52176(7%$&.
,1*5(66(*5(66($6(0(17
0%3*
)52176(7%$&.
('*(2)3$9(0(17 ('*(2)3$9(0(17
;;;;;;;;
;;
;
;
3,3(
67:227(1&253
%.3*
=21,1*,,1'8675,$/',675,&7
&/$66,1',1'8675,$//$1'86(&+(0,&$/ $//,('
)2
86+,*+:$<
38%/,&5,*+72):$<
6($%2$5'&2$67/,1(5$,/52$'
35,9$7
(
5
:
,5)
727$/
/
:
6
(
727$/
1
(
32:(5/,1(($6(0(17
'%3*
87,/,7</,1(($6(0(17'%3*
,1*5(66(*5(66($6(0(17
0%3*
)52176(7%$&.
)52176(7%$&.
,1*5(66(*5(66($6(0(170%3*
'5$,1$*(($6(0(170%3*
'5$,1$*(($6(0(170%3*
/LFHQFH&
,
5
2
1
*
$
7
(
'
5
6
8
,
7
(
:,/
0
,
1
*
7
2
1
1
&
3+
2
1
(
$
6
+
/
,
7
7
/
(
5
,
9
(
5
5
'
1
:
$6
+
1
&
3+
2
1
(
12
5
5
,
6
7
8
1
6
7
$
/
/
&2
1
6
8
/
7
,
1
*
(
1
*
,
1
(
(
5
6
3
&
6&$/(
7-$621&/$5.
(1*,1((5
87
,
/
,
7
<
3
/
$
1
&
35(/
,
0
,
1
$
5
<
86
%
8
6
,
1
(
6
6
3
$
5
.
1
2
5
7
+
:
(
6
7
1
8
6
+
:
<
:,/
0
,
1
*
7
2
1
1
&
8*8*8*
:(//
8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*
*5$
9
(
/
5
2
$
'
:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2
)2)2)2)2)2)2)2)2)2)
2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+(2+
:::::::::::::::::::::
)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0
5&35$::$7(5
8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8
::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0)0
2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2)2
8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*
5&35$::$7(5
:/
)0
/3)0 /3)0
;;;;;;;;
;;
;
;
&0)&0)
',7&+
',7&+
)52176(7%$&.
,1*5(66(*5(66
)52176(7%$&.
$9(0(17('*(2)3$9(0(17
;;;;;;;;
;;
;
;
3,3(
)2
86+,*+:$<
38%/,&5,*+72):$<
727$//1
:
(
87,/,7</,1(($6(0(17 '%3*
,1*5(66(*5(66
)52176(7%$&.
&
6&$/(
/LFHQFH&
+25,=
9(57
,521*$7('568,7(:,/0,1*7211&3+21(
$6+/,77/(5,9(55'1:$6+1&3+21(
1255,6 78167$//&2168/7,1*(1*,1((563&
35(
/
,
0
,
1
$
5
<
7-$621&/$5.
(1*,1((5
8*8*8*
*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*
*5$
9
(
/
5
2
$
'
::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
:::::::::::::::::::::::::::::::
)0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0
5&35$::$7(5
:::::::::::::::::
/3
)0
:
8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*
:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
)0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0 )0
8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*8*
5&35$::$7(5
:/
)0
/3)0/3)0
:/
&/$66,1',1'8675,$//$1'86(&+(0,&$/ $//,('
&0)
32:(5/,1(($6(0(17
'%3*
&0)
)52176(7%$&.
,1*5(66(*5(66($6(0(17
0%3*
)52176(7%$&.
('*(2)3$9(0(17 ('*(2)3$9(0(17 ('*(2)3$9(0(
67:227(1&253
%.3*
=21,1*,,1'8675,$/',675,&7
&/$66,1',1'8675,$//$1'86(&+(0,&$/ $//,('
86+,*+:$<
38%/,&5,*+72):$<
67:227(1&253
5
'
%
3
*
6($%2$5'&2$67/,1(5$,/52$'
35,9$7
(
5
:
,5)
727$/
/
1
:
6
(
727$/
1
(
32:(5/,1(($6(0(17
'%3*
87,/,7</,1(($6(0(17'%3*
,1*5(66(*5(66($6(0(17
0%3*
)52176(7%$&.
,1*5(66(*5(66($6(0(170%3*
'5$,1$*(($6(0(170%3*
'5$,1$*($6(0(170%3*//
&
/LFHQFH&
,
5
2
1
*
$
7
(
'
5
6
8
,
7
(
:,/
0
,
1
*
7
2
1
1
&
3+
2
1
(
$
6
+
/
,
7
7
/
(
5
,
9
(
5
5
'
1
:
$6
+
1
&
3+
2
1
(
12
5
5
,
6
7
8
1
6
7
$
/
/
&2
1
6
8
/
7
,
1
*
(
1
*
,
1
(
(
5
6
3
&
6&$/(
7-$621&/$5.
(1*,1((5
/$
<
2
8
7
3
/
$
1
35(/
,
0
,
1
$
5
<
86
%
8
6
,
1
(
6
6
3
$
5
.
1
2
5
7
+
:
(
6
7
1
8
6
+
:
<
:,/
0
,
1
*
7
2
1
1
&
Pierson’s Pointe – Major Subdivision – TRC Review
Page | 1
To: Jody Waino, Wilmington Realtor’s Foundation, jodyw@kw.com
From: Zach Dickerson, Senior Planner
Date: August 21 2024 TRC Review
PID#: R07900-003-010-000, R07900-003-011-000
Egov# SUBPP-24-0008
Subject: Pierson’s Pointe- Preliminary Plan TRC Review
The following comments have been received for the August 21, 2024, TRC meeting. Additional comments
may be made upon further review of subsequent revisions.
Please note: following the TRC meeting, a revised preliminary plan addressing each of the below items
must be resubmitted prior to receiving preliminary plan approval.
Planning, Zach Dickerson 910-798-7450
1. General Comments
a. Project is tied to conditional rezoning case Z22-02, approved 4/4/2022.
i. 48 units total allowed, 48 proposed in this site plan.
b. This project is a performance subdivision.
c. Please include the condition for this rezoning on the cover page:
i. The project is proposed to meet the price criteria for workforce housing in the
81-120% Area Median Income (AMI) range as defined by the US Department of
Housing and Urban Development, adjusted for household size. Restrictive
covenants will be created to assure owner occupancy and restrict investment or
short term rental.
d. Is each townhome intended to be on its own lot?
2. UDO Section 5.1, Parking and Loading
a. Please show pull-off area for the mailbox kiosk.
b. At least 7’ of width is needed for the pull-off area.
Pierson’s Pointe – Major Subdivision – TRC Review
Page | 2
3. UDO Section 5.2, Traffic, Access and Connectivity
a. Please indicate if this is intended to be a stub road or a fire apparatus turnaround.
4. UDO Section 5.3, Tree Retention
a. It appears that the trees planned for removal on-site will require a Tree Removal Permit.
b. Please apply for a Tree Removal Permit, referencing Section 5.3 of the UDO for details.
5. UDO Section 5.4, Landscaping and Buffering
a. Per UDO Section 5.4.1.A, Single-Family homes being constructed on lots of one acre or
less are exempted from landscaping requirements.
6. UDO Section 5.5, Lighting
a. Is any new lighting proposed for this development?
7. UDO Section 5.6, Signs
a. Please note that any signs are subject to Section 5.6 of the UDO.
8. UDO Section 5.7, Conservation Resources
a. Per the New Hanover County Conservation Overlay District Map, there are no
conservation resources on the site.
9. UDO Section 5.8, Open Space Requirements
a. Open space acreage requirements are met, please ensure this is clearly delineated on the
site plan.
10. UDO Article 6, Subdivision Design and Improvements.
a. Please ensure that sidewalks are labeled.
Pierson’s Pointe – Major Subdivision – TRC Review
Page | 3
NHC Fire Services, Sunnie Batson 910-798-7464
1. Pursuant to the North Carolina Fire Prevention Code and New Hanover County Ordinances
Section 26
2. Required for Plan Review Submittal
3. The complete TRC/Site plans comments from New Hanover County Fire staff shall be submitted
along with the building plans for review to New Hanover County Fire Marshal’s Office. This shall
include the complete set of civil plans. Failure to submit the comments or complete set of civil
plans will result in a resubmittal for review for verification of compliance.
4. Accessibility -Fire apparatus access roads are required at time of construction. They are to be
capable of handling the weight of fire apparatus and be passable in all weather conditions. Fire
apparatus access roads are to be a minimum of 20 feet wide (Chapter 5), unless there are fire
hydrants installed along the roadway then minimum is 26 feet wide (Appendix D). The fire code
official may increase this width as necessary based on potential for fire apparatus response.
Dead end roads greater than 150 feet in length shall require an approved means for fire
apparatus to turn around (Chapter 5 and Appendix D). Fire apparatus access roads shall provide
a clear vertical clearance of 14 feet including trees, canopies, bridges, etc. (Chapter 5
requirement is 13 feet 6 inches, however AHJ requires 14 feet based on local apparatus).
5. Discussed ‘outcropping’ in the areas with hydrants to accommodate proposed road width.
6. The “hammerhead” turnaround at the end of the road is appropriately sized and approved.
7. Street and road signs are required, temporary signs during construction are acceptable provided
they are legible and weather resistant. (Chapter 5).
8. Parking shall not be allowed on either side of the above-mentioned roadway. If roadside parking
is desired the minimum road width shall be increased, contact the fire code official for further
information. No Parking signs shall be a minimum of 12 inches wide and 18 inches tall. (Chapter
5)
9. Gates on fire apparatus access roads are discouraged due to the delay in response. If gated
access is deemed necessary it shall be either staffed with personnel 24 hours per day every day,
365 days of the year or must include KNOX key bypass switch and siren activation (both). Per
NCFC 503.6, submit for review the details and manufacturer information for the gate across the
fire department access road. (Chapter 5).
10. Traffic calming devices are highly discouraged due to the delay in response. Speed
bumps/humps are prohibited. Requests for other traffic calming devices must be evaluated
during the Technical Review (TRC).
11. Premises identification is required. Address and or unit numbers are required on the street side
as well as unit identification on rear access doors. Letters and Numbers shall not be less than 6
inches tall and ¾ inches wide; must be weather resistant and contrasting in color to their
background. (Chapter 5). Buildings constructed under the 2018 code shall require additional
signage per Appendix J.
Pierson’s Pointe – Major Subdivision – TRC Review
Page | 4
12. Water Supply (Chapter 5 and Appendix C) If a water supply is required for fire protection a fire
hydrant system or other means approved by the fire code official must be present prior to
beginning construction and be maintained operable during the construction period. (For
construction, fire dept. water shuttle counts as long there is a fill site within range.)
13. A fire flow test shall be conducted in accordance with NFPA 291 and NCFC 507.4, and a report
indicating the available fire flow, stamped by a PE is required to be submitted with documents
for Plans Review. (NCFC 507.1)
14. Per the Engineer, CFPUA 16” water main will be extended to the entrance of the property, and
the proposed hydrant locations are appropriately spaced and approved.
15. If an approved water supply capable of supplying the required fire flow for fire protection is
available, fire hydrants shall be provided.
16. Fire Hydrants
17. All fire hydrants shall have a 5 ¼ inch barrel, a 5 ¼ inch valve opening, two 2 ½ inch NST side
discharges and a 5-inch pumper nozzle with a 5-inch STORZ connection. Further information on
the technical specifications is available from the fire code official or Cape Fear Public Utility
Authority.
18. All fire hydrants shall be installed so they are visible from the fire apparatus access road with
unobstructed access and a clear space no less than 36 inches in all directions. They shall be
protected from vehicle impact by curbing, guard posts or other means approved by the fire code
official. They shall be oriented with the large discharge facing the nearest street. All discharges
shall meet the NFPA requirements for distance above grade.
19. Fire hydrants in general residential areas shall be installed so that all insured properties are
within 500 feet of a hydrant (hydrant spacing approximately 1000 feet apart along a fire
apparatus access road, installed at intersections where possible). The first fire hydrant should be
installed at or near the entrance to the residential area.
20. Construction and Demolition
21. All construction and demolition work must comply with NCFC Chapter 33.
NHC Engineering, Galen Jamison 910-798-7072
1. A land disturbing issued by the County is required for this project. Please digitally submit the
permit application documentation with requisite review fees for County issued permit directly
to gjamison@nhcgov.com. Application and forms can be found at
https://www.nhcgov.com/249/Sediment-Erosion-Control.
2. A County stormwater permit issued by the County is required for this project. Please digitally
submit the permit applications documentation with requisite review fees to the COAST online
permit portal (https://newhanovercountync-
energovpub.tylerhost.net/apps/selfservice#/home). Applicable forms can be found at
Pierson’s Pointe – Major Subdivision – TRC Review
Page | 5
https://www.nhcgov.com/251/Stormwater however the application form is not required as the
information will be gathered by the COAST portal.
3. Please contact the State for the stormwater permit modification requirements.
4. The offsite stormwater drainage coming from the south and north to the existing low point
located in between the 40 contour will need to be routed through or around the site and placed
in a public drainage easement sized in accordance with NHC Stormwater Manual. Construction
of offsite drainage conveyance measures that will be maintained by the county will need to be
observed during construction by Stormwater Services and a turnover meeting scheduled once
the system is ready to be conveyed to the county. Please add a plan note to ensure county
construction observation and a turnover meeting occurs. Note, should the applicant elect to
maintain the conveyance measures themselves, the POA covenants shall indicate the operation
and maintenance roles and responsibilities for the conveyance measure.
5. The resulting changes to the watershed from both offsite and onsite drainage appears to impact
adjacent and downstream property owners. Therefore, and in accordance with NHC Stormwater
Ordinance, Section 7.8.B, last paragraph, a stormwater impact analysis will be required at Blake
Trail and/or County Place Road. Impact upstream to the north and south may also be necessary.
Please have the designer of record contact our office prior to initiating the analysis. The County
has developed a conceptual master plan for the two watersheds impacted by this
development.
6. Has the adjacent property agreed to the drainage easement?
7. What are the eastern limits of the 404 wetlands? Consideration should be given to defining a
conveyance measure outside the 404 wetlands.
8. It is unclear how the concentrated flow created by the bypass swales will discharge onto an
existing slope on the adjacent property.
NHC Environmental Health, Dustin Fenske 910-798-6732
1. Site plan reflects connection to public water.
2. Environmental Health has site plans that show existing wells at 6229 and 6227 Carolina Beach
Rd. These wells must be located, protected during demolition and properly abandoned by a
Certified Well Driller. Environmental Health could not find any well records for 6223 or 6221
Carolina Beach Rd. However, these properties probably had a well on site. Developer must be
mindful to locate any existing well heads around these old dwellings then protect and properly
abandon these wells. There is a well head at 6217 Carolina Beach Rd. The proposed sewage lift
station must maintain 100 feet from this well head.
3. Site plan reflects a connection to public sewer.
4. Any existing dwellings on these sites must have the old septic tanks pumped, crushed and filled
for proper abandonment. Proposed infrastructure will not violate setbacks to any surrounding
properties septic systems.
Pierson’s Pointe – Major Subdivision – TRC Review
Page | 6
NHC Addressing, Katherine May 910-798-7443
1. 1 street name is required. Please email me with street name suggestions prior to TRC approval.
2. Suffix options are as follows: Court, Place, Lane, Way, Row, Run
3. Contact me for address assignments after TRC approval. kmay@nhcgov.com
Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620
1. CFPUA TRC Comments provided are preliminary comments only.
2. Utility Plan review required by CFPUA. CFPUA is moving toward becoming paperless. When
ready to submit plan review package, upload all documents to
https://www.cfpua.org/FormCenter/Engineering-3/Engineering-Plan-Review-103.
3. CFPUA water available via mainline extension.
4. CFPUA sewer will be available via a mainline extension and pump station.
5. Capacity is dependent on the analysis of the pipe collection system (gravity and force mains).
6. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE Application
Form and a Preliminary Plan, this determination does not guarantee capacity.
7. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the
plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the
Authority.
NCDOT, Nick Drees 910-343-3915
1. Please see attachment.
WMPO, Abby Lorenzo 910-473-7890
1. Comments forthcoming
Army Corps of Engineers, Brad Shaver 910-251-4611
1. The Corps has confirmed the wetland line depicted. If impacts occur in this area a permit will be
triggered.
Comments not received at this time from:
Emergency Services & E911, Steve Still
NCDEQ, Chad Coburn
New Hanover Soil & Water, Dru Harrison
NCDEMLR, Dan Sams
DCM, Tanya Pietila
STATE OF NORTH CAROLINA
DEPARTMENT OF TRANSPORTATION
ROY COOPER J.R. “JOEY” HOPKINS
GOVERNOR SECRETARY
Mailing Address:
NC DEPARTMENT OF TRANSPORTATION
DISTRICT 3 ENGINEER’S OFFICE
5911 OLEANDER DRIVE, SUITE 101
WILMINGTON, NC 28403
04-11-03 COURIER
Telephone: 910-398-9100
Customer Service: 1-877-368-4968
Website: ncdot.gov
Location:
5911 OLEANDER DRIVE, SUITE 101
WILMINGTON, NC 28403
Memorandum
To: New Hanover County Technical Review Committee
Date: August 6, 2024
Subject: Pierson Point Townhomes – 6221 Carolina Beach Road
________________________________________________________________________
These are preliminary comments and are based on the plans as submitted for the proposed
site. They are subject to further review upon receipt of any additional information.
Subsequently, additional comments and/or requirements may be necessary for this site.
General Comments:
NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT
Online Portal.https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx
NCDOT Driveway Permit:
An NCDOT Driveway Permit is required. Submit plans in accordance with pages 14 and
15 of the Policy on Street and Driveway Access to North Carolina Highways to include
access locations within 500’ of the proposed access on both sides of the State Road.
Submit to the local NCDOT District Engineer’s Office.
x Refer to the NCDOT checklist (included) for required documents and site plan
information.
NCDOT Encroachment Agreement:
An NCDOT Encroachment Agreement is required for any utility connections or
installations within the NCDOT right-of-way (form 16.6).
x It is recommended that you reach out to the NCDOT District Office prior to
submitting plans to avoid a redesign of the proposed utilities.
x Refer to the NCDOT UAM Manual and the NCDOT encroachment checklist for
required documents and site plan information.
An NCDOT Encroachment Agreement is required for any sidewalk or multi-use paths
installed within the NCDOT right-of-way (form 16.6).
Mailing Address:
NC DEPARTMENT OF TRANSPORTATION
DISTRICT 3 ENGINEER’S OFFICE
5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403
04-11-03 COURIER
Telephone: 910-398-9100
Customer Service: 1-877-368-4968
Website: ncdot.gov
Location:
5911 OLEANDER DRIVE, SUITE 101
WILMINGTON, NC 28403
Roadway Improvements:
Submit a turn lane warrant analysis to verify if any roadway improvements will be
needed/required.
Refer to the NCDOT Roadway Design Manual for help with the design of any required
roadway improvements.
Site Plan Comments:
Hydraulic calculations and associated plan sheets will need to be submitted for the
site.
x This will be reviewed by the NCDOT Hydraulics Unit.
x If existing topography does not historically drain to the NCDOT right-of-way, it
must not be diverted to the NCDOT right-of-way post development.
Driveway Alignment:
x The current proposed alignment of the driveway should be shifted south to better
align with Carolina Beach Road.
x Provide turning templates for the largest proposed vehicle.
Sight Triangles and Sight Distance:
x Show and label the stopping sight distance.
o No obstructions shall be placed within the stopping sight distance.
You can coordinate with the district office with any questions 910-398-9100.
NCDOT | Division 3 | District 3 Project Name:_____________________________ Date:_______________
Applicant
Checklist NCDOT
Checklist
Driveway Application Process and Site Plan Requirements
ALL APPLICATIONS SHALL BE ACCOMPANIED BY COMPLETE AND DETAILED SITE PLANS THAT ADHERE TO THE POLICIES LISTED IN THE POLICY ON STREET AND
DRIVEWAY ACCESS TO NORTH CAROLINA HIGHWAYS AND THIS DOCUMENT. FAILURE TO ADHERE TO THESE POLICIES WILL RESULT IN THE RETURN OF THE
APPLICATION TO THE APPLICANT FOR REVISION.
***THE NCDOT WILL NOT BEGIN THE REVIEW PROCESS ON INCOMPLETE APPLICATIONS***
Electronic Pre-Submittals
In an effort to save time and resources, we are happy to provide an initial assessment of a driveway permit submittal’s plans via email to
identify any major issues up front. This initial assessment can be followed up with a submittal ŽĨŽŶĞĚŝŐŝƚĂůĐŽƉLJŽĨƚŚĞƉůĂŶƐ along with all
other required documents.
ůůWĞƌŵŝƚĂƉƉůŝĐĂƚŝŽŶƐƐŚĂůůďĞƐƵďŵŝƚƚĞĚƚŚƌŽƵŐŚƚŚĞŽŶůŝŶĞƉŽƌƚĂůŚƚƚƉƐ͗ͬͬĐŽŶŶĞĐƚ͘ŶĐĚŽƚ͘ŐŽǀͬƐŝƚĞͬWĞƌŵŝƚƐͬWĂŐĞƐͬĚĞĨĂƵůƚ͘ĂƐƉdž
/ŶƚŚĞŶŽƚŝĨLJĞŵĂŝůƐĞĐƚŝŽŶŽĨƚŚĞƉŽƌƚĂůĂƉƉůŝĐĂƚŝŽŶƉůĞĂƐĞŝŶĐůƵĚĞƚŚĞŝƐƚƌŝĐƚKĨĨŝĐĞĞŵĂŝů;ŝǀϯŝƐƚϯΛŶĐĚŽƚ͘ŐŽǀͿ͘^ĞĞƚŚĞůĂƐƚƉĂŐĞƐĨŽƌĨƵƌƚŚĞƌŝŶƐƚƌƵĐƚŝŽŶ͘
Online resources:
x NCDOT Policy on Street and Driveway Access to North Carolina Highways:
https://connect.ncdot.gov/projects/Roadway/RoadwayDesignAdministrativeDocuments/Policy%20on%20Street%20an
d%20Driveway%20Access.pdf
x NCDOT Policies and Procedures for Accommodating Utilities on Highway Rights of Way:
https://connect.ncdot.gov/municipalities/Utilities/Pages/UtilitiesManuals.aspx
x Electronic Forms Database:
https://connect.ncdot.gov/Pages/default.aspx
1)
Ă͘Cover >etter
Include contact information for applicant and engineer, including email address, mailing address, and phone
number. Include ƚŚĞƉĂƌĐĞůŶƵŵďĞƌ;ƐͿ͕description of all phases of the development and future land uses to be
served by the permit,ĂŶĚa description of the adjoining land owned or controlled by the applicant.
ď͘NCDOT Street and Driveway Access Permit Application (form downloadable via link below)
https://connect.ncdot.gov/resources/BusinessForms/TEB-65-04.doc
Đ͘$50.00 /nspection &eeWĞƌĐĐĞƐƐWŽŝŶƚ
Attach to Permit Application form (not applicable for municipalities, churches, and schools)
Ě͘NPDES Stormwater Permit Compliance Certification (form downloadable via link below)
https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/NPDESstatement.doc
Ğ͘Verification of Compliance with Environmental Regulations (form downloadable via link below)
https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/VCER-1.pdf
Ĩ͘Site Plans (to include the “Master Plan” of a tract even if only a small portion is being developed first)Additional
site plan requirement details can be found in section 2 of this document.
Ő͘ĞƐŝŐŶ PlanZĞƋƵŝƌĞŵĞŶƚƐ ĨŽƌƉƌŽũĞĐƚƐŝŶǀŽůǀŝŶŐƌŽĂĚǁĂLJŝŵƉƌŽǀĞŵĞŶƚƐ
If roadway improvements are required as part of the permit, ƚŚĞŶroadway plans͕ƉĂǀĞŵĞŶƚŵĂƌŬŝŶŐƉůĂŶƐ͕
ƐŝŐŶŝŶŐƉůĂŶƐ͕ĂŶĚƚƌĂĨĨŝĐĐŽŶƚƌŽůƉůĂŶƐǁŝůůďĞƌĞƋƵŝƌĞĚͲ^ĞĞ^ĞĐƚŝŽŶϲĨŽƌŵŽƌĞŝŶĨŽƌŵĂƚŝŽŶ
Y N n/a
Engineering Studies
The applicant may be required by the District Engineer to submit studies based on, but not limited to, the parameters outlined
herein. If study requirements of the local government agency are more restrictive than the NCDOT requirements, then local
government requirements will govern. However, this does not imply that the NCDOT is obligated to approve entrance designs
that are too constrictive to allow smooth and safe traffic flow. All studies including, but not limited to, Traffic Impact Analyses
(TIA), traffic signal studies, and drainage studies, must be prepared under the direct charge of and sealed by a North Carolina
licensed Professional Engineer.
Section 1: Requi
red Documents
|Required documents to accompany all /ŶŝƚŝĂůƌŝǀĞway Application Submittals
WůĞĂƐĞŶŽƚĞƚŚĂƚƚŚĞƐĞĂƌĞƚŚĞŵŝŶŝŵƵŵƌĞƋƵŝƌĞŵĞŶƚƐŽĨĂůůĚƌŝǀĞǁĂLJƉĞƌŵŝƚĂƉƉůŝĐĂƚŝŽŶƐ͘
ůůƌĞƋƵŝƌĞĚĚŽĐƵŵĞŶƚĂƚŝŽŶƐŚĂůůďĞƐƵďŵŝƚƚĞĚƚŚƌŽƵŐŚƚŚĞŽŶůŝŶĞƉŽƌƚĂůĂƐW&ĨŝůĞƐ͕ǁŝƚŚƚŚĞĞdžĐĞƉƚŝŽŶŽĨƚŚĞ
WĞƌĨŽƌŵĂŶĐĞĂŶĚ/ŶĚĞŵŶŝƚLJŽŶĚĂŶĚƚŚĞΨϱϬ/ŶƐƉĞĐƚŝŽŶ&ĞĞ;ƐͿ͕ƚŚĞƐĞƐŚŽƵůĚďĞŵĂŝůĞĚŽƌĚĞůŝǀĞƌĞĚƚŽϱϱϬϭ
ĂƌďĂĚŽƐůǀĚ͕ĂƐƚůĞ,ĂLJŶĞ͕EϮϴϰϮϵ͘
If a Traffic Impact Analysis and/or roadway improvements are deemed necessary as a condition of the permit͕ƚŚĞƌĞ
ŵĂLJďĞĂĚĚŝƚŝŽŶĂůƐƵďŵŝƚƚĂůŵĂƚĞƌŝĂůƐƌĞƋƵŝƌĞĚ͘
State of North Carolina | Department of Transportation | Division 3 | District 3
%DUEDGRV%OYG,&DVWOH+D\QH, NC 284
Form Updated/20(910) T NCDOT Permit #___________________
Y N n/a
Section 1: Required Documents (continued)
2)Required documents to accompany all Driveway Applications PRIOR TO FINAL APPROVAL
Ă͘Site Plans
Kne (1) digital copy (PDF) unless otherwise requested bythe District Office. Additional site plan requirement
details can be found in section 2 of this document.
ď͘Performance and Indemnity Bond/ŶĨŽƌŵĂƚŝŽŶͬFormƐ
^ĞĞůĂƐƚƉĂŐĞŽĨĚŽĐƵŵĞŶƚĨŽƌďŽŶĚŝŶĨŽƌŵĂƚŝŽŶĂŶĚĨŽƌŵƐ
Đ͘Performance and Indemnity Bond Amount
100% of ƚŚĞĐŽƐƚŽĨƚŚĞǁŽƌŬwithin NCDOT Zight-of-tay;ZͬtͿ based on ƚŚĞattached estimatedetermined by
ƚŚĞĂƉƉůŝĐĂŶƚΖƐĞŶŐŝŶĞĞƌĂŶĚĂƉƉƌŽǀĞĚďLJƚŚĞDistrict Engineer. ŽŶĚŚŽůĚůĞƚƚĞƌƌĞƋƵŝƌĞĚĨŽƌĨŽƌŵƵŶŝĐŝƉĂůŝƚŝĞƐ͕
ĐŚƵƌĐŚĞƐ͕ĂŶĚƐĐŚŽŽůƐ͘See pages 101-105 in the Policies and ProceduresforAccommodatingUtilities on Highway
Rights of Way for acceptable bond types
Ě͘Radius Encroachment Letter (if applicable)
If driveway radius encroaches on the frontage of an adjacent property, a Radius Encroachment will be required
Ğ͘Hold Harmless Letter (if applicable)
If the Wermit is within ƚŚĞůŝŵŝƚƐŽĨĂŶ active NCDOT project, a Hold Harmless letter from the NCDOT contractorwill
be required͘/ĨƚŚĞƉƌŽũĞĐƚŝƐŝŶƉƌĞĐŽŶƐƚƌƵĐƚŝŽŶ͕ĐŽŽƌĚŝŶĂƚĞǁŝƚŚƚŚĞĞƉĂƌƚŵĞŶƚΖƐWƌŽũĞĐƚĞǀĞůŽƉŵĞŶƚhŶŝƚ
Section 2: General Site Plan Requirements | All site plans shall include and show, at a minimum, the items listed below
Page numbers reference the NCDOT Policy on Street and Driveway Access to North Carolina Highways
ϭͿ Drawn to a scale of 20, 30, 40, or 50 feet per inch and the scale shall be shown
ϮͿ North arrow, vicinity map, date of plan, and date of most-recent revision if applicable
ϯͿ Contact information of applicant and engineer, including mailing address, phone number, and email address
ϰͿ Show Zͬt lines, highway control of access, and property lines
ϱͿ All existing utilities (including handholes) and easements
ϲͿ Rͬt width
ϳͿ Existing posted speed limit(s) and design speed limit(s)
ϴͿ Show all property lines, intersections, signals, signal loops, railroads, or crossovers within 500’ in all directions of
the property lines of the proposed development
ϵͿ Show location of sidewalks, crosswalks, greenways, multi-use paths, curb ramps, railroads, bus stops, and any
other relevant transportation facilities in the development area
ϭϬͿ Include a plan sheet showing full site build-out and land use
ϭϭͿ Buildings shown with “gross leasable area”
ϭϮͿ Width of property frontage
ϭϯͿ Distance from Rͬt to buildings and gasoline service islands
ϭϰͿ Distance from Rͬt to existing/proposed ĚŐĞŽĨWĂǀĞŵĞŶƚ;KWͿ (pages 32 & 34)
ϭϱͿ All streams, bridges, retaining walls, signs, or other fixed objects such as trees, utility poles, traffic signals, etc.
Section 3: Driveway Plan Requirements
|
All driveway plans shall include and show, at a minimum, the items listed below
ϭͿ WƌŽǀŝĚĞĐŽŵƉƌĞŚĞŶƐŝǀĞƐƵƌǀĞLJǁŝƚŚŝŶƚŚĞĞdžŝƐƚŝŶŐZͬtŽŶďŽƚŚƐŝĚĞƐŽĨƚŚĞƌŽĂĚĨŽƌĂĚŝƐƚĂŶĐĞŽĨϱϬϬ͛ŝŶĂůů
ĚŝƌĞĐƚŝŽŶƐĨƌŽŵƚŚĞĚĞǀĞůŽƉŵĞŶƚ͛ƐƉƌŽƉĞƌƚLJůŝŶĞƐ͘WƌŽǀŝĚĞĂĚĚŝƚŝŽŶĂůŚLJĚƌĂƵůŝĐƐƵƌǀĞLJĚĂƚĂƚŽƚŚĞŶĞĂƌĞƐƚƐƚŽƌŵ
ǁĂƚĞƌŝŶůĞƚͬŽƵƚůĞƚŝŶĐůƵĚŝŶŐĚŝƚĐŚůŝŶĞƐĂŶĚƐƚŽƌŵǁĂƚĞƌƉŝƉĞƐ͕ŝĨůŽĐĂƚĞĚŽƵƚƐŝĚĞŽĨƚŚĞϱϬϬΖĚŝƐƚĂŶĐĞ͘
ϮͿ Lane configurations and widths of all existing and proposed driveways, roadways, and adjacent roadways
ϯͿ All driveway widths (2-way: 20’ minimum, 36’ maximum | 1-way: 12’ minimum, 24’ maximumͮǁŝƚŚŝƐůĂŶĚ͗ϭϰΖ
ŝŶŐƌĞƐƐ͕ϭϴΖĞŐƌĞƐƐ) (pageƐϱϬΘϳϳ)
ϰͿ ƌŝǀĞǁĂLJWƌŽĨŝůĞͲ/ŶƐŚŽƵůĚĞƌƐĞĐƚŝŽŶƐ͕ŵaintain minimum 2% fall from edge of travel way for required
shoulder width ĚŝƐƚĂŶĐĞWƌŝŵĂƌLJ͗ϴ͛ŵŝŶŝŵƵŵͮ^ĞĐŽŶĚĂƌLJ͗ϲ͛ŵŝŶŝŵƵŵ
ϱͿ All existing and/or proposed driveway radii (20’ minimum, 50’ maximum, 30’ typical) (pages 34 & 51)
In curb and gutter sections, use City of Wilmington flare (SD 3-03.3)Ͳ;ƐĞĞĂƚƚĂĐŚĞĚͿ
In shoulder sections, show grades at the KW and centerline
ϲͿ No curbing is allowed within NCDOT RͬW along shoulder sections except as part of a driveway island(page 31)
ϳͿ Driveway angles of approach to existing roadway (90° preferred, 75°-90° required for 2-way driveways, 45°-90°
allowed for right-in/right-out on a case-by-case basis) (page 51)
ϴͿ Driveway Wrofile (pages 42- 43)
Y N n/a Y N n/a
පප පපප ප
Y N n/a Y N n/a
Y N n/a Y N n/a
Section 3: Driveway Plan Requirements (continued)
ϵͿ Driveway Pavement Cross Section (to be in place from KW to edge of RͬW)
Asphalt: 8” ABC stone and 1.5” S9.5
Concrete: 6” of concrete
ϭϬͿ Driveway Offset (driveway KW to property line; page 75): Minimum: 20’
ϭϭ)Corner Clearance (radius point to radius point; page 52) Minimum: 50’ Desirable: 100’ or DƵŶŝĐŝƉĂů std.
ϭϮͿ Minimum 10’x70’ sight triangles at driveways (measured from and along the Zͬt line) (page 31)
ϭϯͿ Sight Distance (ůength of sight-distance in both directions shown for each driveway; pages 27-29)
ϭϰͿ Driveways should be aligned with existing opposing driveways or correct offset should be provided (pages 40-41)
ϭϱͿ Distance between driveways being requested (if applicable; page 51)
ϭϲͿ Minimum internal storage areasǁŝƚŚƐƉĞĐŝĨŝĞĚƋƵĞƵĞƐ (pages 31-33)
ϭϳͿ Minimum protected driveway stem(s) provided and indicated (pages 33-34)
ϭϴͿ Indicate any gated entrances (100’ minimum setback from RͬW required)ͲƚƌĂĨĨŝĐƋƵĞƵŝŶŐƐƚƵĚLJŵĂLJďĞƌĞƋƵŝƌĞĚ
|
Section ϲ: Roadway
Plan Requirements
If off-site improvements are required, roadway plans shall show, at a minimum, the items below
ϭͿ Full width typical sections must be shown (paved shoulders to match the typical section of the adjacent roadway)
ϮͿ Minimum Asphalt Typical Section (for turn lanes and/or paved shoulders)
Adjacent recently-completed or upcoming TIP projects w/ different typical sections may supersede those below
x Primary Routes (US & NC) and Secondary Routes with ŶŶƵĂůǀĞƌĂŐĞĂŝůLJdƌĂĨĨŝĐ;AADTͿшϭϬ,000
5͘ϱ” B25.0, 3” I19.0, ϭ͘ϱ” S9.5; any overlay of existing pavement is to be a minimum of 1.5” S9.5
x Secondary Routes with AADT<ϭϬ,000
5͘ϱ” B25.0, ϭ͘ϱ” Sϵ͘ϱ; any overlay of existing pavement is to be a minimum of 1.5” Sϵ͘ϱ
ϯͿ Pavement overlay is required if modification of existing pavement markings and/or lanes is necessary
The grinding of pavement markings will not be allowed
ϰͿ Shoulder Widths (Paved + Unpaved)WƌŝŵĂƌLJ͗ϴ͛ŵŝŶŝŵƵŵͮ^ĞĐŽŶĚĂƌLJ͗ϲ͛ŵŝŶŝŵƵŵ
ϱͿ ŝƚĐŚ^ůŽƉĞƐͲĨƌŽŶƚĂŶĚďĂĐŬƐůŽƉĞƐͲŵŝŶŝŵƵŵϯ͗ϭŽƌĨůĂƚƚĞƌ
ϲͿ Indicate existing roadway grade
ϳͿ All taper lengths and deceleration lengths should be appropriately designed for the given design speed (page78)
ϴͿ All turn lanes should be designed according to the Driveway Manual and Roadway Standard Drawings (page 79)
See 1205.04 Sheets 1 & 2 and 1205.05 Sheet 1 of the Roadway Standard Drawings for details
ϵͿ Pavement markingĂŶĚƐŝŐŶŝŶŐ planƐ ĂƌĞƌĞƋƵŝƌĞĚͲplans must be approved by Division Traffic Services
ϭϬͿ dƌĂĨĨŝĐĐŽŶƚƌŽůƉůĂŶƐĂƌĞƌĞƋƵŝƌĞĚͲĞƚĂŝůĞĚƉŚĂƐŝŶŐƉůĂŶƐŵĂLJďĞƌĞƋƵŝƌĞĚďĂƐĞĚŽŶƉƌŽũĞĐƚƚLJƉĞĂŶĚůŽĐĂƚŝŽŶ
ϭϭͿ EĞǁĂŶĚͬŽƌƌĞǀŝƐĞĚƐŝŐŶĂůƉůĂŶƐŵƵƐƚďĞŝŶĐůƵĚĞĚĨŽƌŶĞǁŝŶƐƚĂůůĂƚŝŽŶƐĂŶĚŝĨƐŝŐŶĂůŵŽĚŝĨŝĐĂƚŝŽŶƐĂƌĞƌĞƋƵŝƌĞĚ
ůůsignal plans must be reviewed and approved by Division Traffic Services and the Signal Design Unit. ATraffic
Agreement must be completed to facilitate the review. Contact Division Traffic Services at (910) 341-ϮϮϬϬ.
|
Section ϰ: Drainag e Requirements
All drainage features on NCDOT Right-of-Way shall adhere to, at a minimum, the items listed below
Section ϱ: Internal Circ ulation Requirements
|All internal circulation details shall adhere to, at a minimum, the items listed below
ϭͿ Interior driveway channelization stems
Minimum 100’ from the RKW or at the discretion of the District Engineer
ϮͿ Traffic flow pattern
ϯͿ Traffic control devices
ϰͿ Pavement Markings
Y N n/a Y N n /a
Y N n/a Y N n/a
Y N n/a Y N n/a
Y N n/a Y N n/a
ϭͿ Pipe Cover Minimums (measured from top of pipe to subgrade)
High Density Polyethylene (HDPE): Ϯϰ” | Corrugated Aluminum (CAP): 12” | Reinforced Concrete (RCP): 12”
ϮͿ WŝƉĞŶĚdƌĞĂƚŵĞŶƚ;ƐĞĞZŽĂĚǁĂLJĞƐŝŐŶDĂŶƵĂůϱͲϮϬ͕ͲϮͿ
WŝƉĞƐчϮϰΗŽŶŵƵůƚŝůĂŶĞŚŝŐŚǁĂLJƐƉŽƐƚĞĚĂďŽǀĞϰϱŵƉŚƌĞƋƵŝƌĞWĂƌĂůůĞůWŝƉĞŶĚ^ĞĐƚŝŽŶƐ^ĞĞϯϭϬ͘ϬϮĂŶĚ
ϯϭϬ͘ϬϰŽĨƚŚĞZŽĂĚǁĂLJ^ƚĂŶĚĂƌĚƌĂǁŝŶŐƐĨŽƌĚĞƚĂŝůƐ
WŝƉĞƐхϯϬΗŽŶŵƵůƚŝůĂŶĞŚŝŐŚǁĂLJƐƉŽƐƚĞĚĂďŽǀĞϰϱŵƉŚƌĞƋƵŝƌĞŐƵĂƌĚƌĂŝů
WŝƉĞƐшϯϲΗƌĞƋƵŝƌĞĂŶĞŶĚǁĂůůŽŶƚŚĞŝŶůĞƚĞŶĚ
ϯͿ ůůƉƌŽƉŽƐĞĚƌĂŝŶĂŐĞŝƐƚŽďĞƉƌŽǀŝĚĞĚŝŶƐŝĚĞĞdžŝƐƚŝŶŐZͬt͘KƚŚĞƌǁŝƐĞ͕ĂĚĚŝƚŝŽŶĂůZͬtŽƌĂƉĞƌŵĂŶĞŶƚůLJ
ĚĞĚŝĐĂƚĞĚĚƌĂŝŶĂŐĞĞĂƐĞŵĞŶƚǁŝůůďĞƌĞƋƵŝƌĞĚƚŽĂĐĐŽŵŵŽĚĂƚĞƚŚĞƉƌŽƉŽƐĞĚƉƌŽũĞĐƚĚƌĂŝŶĂŐĞ
ϰͿ All sizes, types, and invert elevations of existing/proposed pipes and drainage structures must be shown
;ƐĞĞ^ĞĐ͘ϯηϭĨŽƌƐƵƌǀĞLJƌĞƋƵŝƌĞŵĞŶƚƐͿ
ϱͿ Provide spot elevations along frontage of driveway (at EKW and centerline)
ϲͿ Provide grades and spot elevations for existing and proposed ditches
ϳͿ Show how drainage will be accommodated along property frontage
(District Engineer may require applicant to provide drainage calculations whĞŶǁĂƌƌĂŶƚĞĚͿ