Loading...
HomeMy WebLinkAbout2024-007 Reagan Retail and Office Center_8-29-24SI D E W A L K MH 25' 25 ' P U B L I C U T I L I T Y E A S E M E N T DB . 4 3 1 8 / P G . 0 3 1 3 PROP. PARKING 24 PECAN INV.15.66' INV.15.60' 24 " R C P <= 1 5 " R C P INV. OUT=13.45' INV.IN=15.35' <= 1 8 " R C P SE W E R L I N E = > INV.OUT=14.67' (N) INV.IN=14.74' (S) RIM=17.52' SSMH D/W GRAV. D/W CONC. TT T CA S T L E H A Y N E R O A D 4" E I P - D I S T U R B E D 25.00' 10 0 ' P U B L I C R I G H T - O F - W A Y N. C . H W Y 1 3 3 n/f CIRCLE K STORES INC BK 6634, PG 1085 Zoning: B-2 Use: VACANT n/f JEFFREY SUTTON HEIRS ETAL BK 9908, PG 0318 Zoning: B-2 Use: COMMERCIAL n/f TONI L SUTTON BK 5240, PG 0048 Zoning: B-2 Use: COMMERCIAL n/f MCCLURE MEMORIAL PRESBYTERIAN BK 1708, PG 0544 Zoning: B-2 Use: CHURCH n/f NEFTALI BALDERAMA GARCIA BK 6283, PG 2899 Zoning: RA Use: Single Family Residence n/f HILLSBOROUGH STREET LLC BK 6472, PG 1344 Zoning: B-2 Use: COMMERCIAL n/f CAROLINE L. BORDEAUX BK 3665, PG 0818 Zoning: RA Use: Single Family Residence n/f SIMON P PARKIN BK 1536, PG 2092 Zoning: B-2 Use: Single Family Residence 13 14 14 14 14 14 14 14 16 16 16 16 16 16 16 1 6 16 1 6 16 16 17 17 17 17 17 17 17 17 17 17 1 7 17 17 17 17 17 18 1 8 1 8 1 8 1 8 18 1 8 18 1 8 18 18 19 19 1 9 19 21 2 1 21 2 1 22 22 2 2 15 15 15 15 15 15 15 15 15 15 15 20 20 2 0 EXISTING BUILDING C-0 1 EX I S T I N G C O N D I T I O N S , T R E E RE M O V A L / P R O T E C T I O N A N D DE M O L I T I O N P L A N 1" = 30' PROPERTY LINE ADJOINERS TREE PROTECTION FENCE LIMITS OF DISTURBANCE TREES TO BE REMOVED LEGEND REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): 2024-007 CLIENT INFORMATION: Reagan, LLC 303 Fox Lake Dr. Clinton, NC 28328 OF 7 JAE CDC CDC 24x36 8/29/2024 RE A G A N R E T A I L A N D OF F I C E C E N T E R SITE BLU E C L A Y R D NORTH KERR AVE NORTH KERR AVE O L D W R I G H T S B O R O R D AC O R N B R A N C H R D S R 1 3 1 9 SR 1 3 7 0 PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N SITE U S 4 2 1 B E A C H R D NC 1 3 2 S C O L L E G E R D MA S O N B O R O PI N E R R D GR O V E R D US 4 2 1 MY R T L E LO O P R D C A R O L I N A SITE CA S T L E H A Y N E R D LYNN AVE. CASTLE AVE. SITE CA S T L E H A Y N E R D LYNN AVE. CASTLE AVE. SITE CA S T L E H A Y N E R D CASTLE AVE. HOLLY SHELTER R D . SITE DATA PARCEL ID:R01109-001-001-000 CURRENT ZONING:B-2 PROJECT ADDRESS:5901 CASTLE HAYNE RD. CASTLE HAYNE, NC 28429 CURRENT OWNER:REAGAN LLC 303 FOX LAKE DR. CLINTON, NC 28328 TOTAL ACREAGE IN PROJECT BOUNDARY 6) “DF EXISTING ONSITE IMPERVIOUS AREAS: (SITE IS VACANT) SOILS TYPE: Ke (Kenansville fine sand) Ls (Lynchburg fine sandy loam) (Per NHC GIS Soil Map) NOTES: 1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY LAND DEVELOPMENT CODE. 2. PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS. 3. EXISTING SURVEYING PERFORMED BY STEVEN L. BUIE, PLS, L-3402. 4. SITE IS LOCATED IN ZONE "X" PER FRIS ON FIRM MAP NUMBER370168 3232 K, EFFECTIVE DATE FEBRUARY 16, 2007. 5. NO WETLANDS, SURFACE WATERS, PROTECTED VEGETATED SETBACKS OR RIPARIAN BUFFERS EXIST ON SITE. 6. PRIOR TO CLEARING, GRADING, OR CONSTRUCTION ACTIVITY, ANY WELLS THAT ARE EXISTING MUST BE PROTECTED AROUND EACH WELL HEAD/CASING AND CAPPED. 7. ALL PINE TREES ARE ASSUMED TO BE LOBLOLLY PINES. ALL GUM TREES ARE ASSUMED TO BE SWEET GUMS. CONTRACTOR TO VERIFY SPECIES PRIOR TO CUTTING. TREE PRESERVATION NOTES: 1. PRIOR TO ANY CLEARING, GRADING, OR CONSTRUCTION ACTIVITY, APPROVED TREE PROTECTION FENCING, SUCH AS SAFETY BARRIER FENCING, A WOODEN SLAT SNOW FENCE OR WIRE FENCE, SHALL BE INSTALLED AROUND PROTECTED TREES OR TREE STANDS LOCATED IN CONSTRUCTION AREAS OR OTHER SITE AREAS THAT WILL BE DISTURBED BY CONSTRUCTION ACTIVITIES. THE FENCING SHALL BE A MINIMUM OF FOUR FEET IN HEIGHT AND BE OF DURABLE CONSTRUCTION. TREE PROTECTIVE FENCING SHALL REMAIN IN PLACE THROUGH COMPLETION OF CONSTRUCTION ACTIVITIES. 2. NO CONSTRUCTION WORKERS, TOOLS, MATERIALS, OR VEHICLES ARE PERMITTED WITHIN THE TREE PROTECTION FENCING. 3. IF AN EXISTING TREE RETAINED TO COMPLY WITH THE STANDARDS OF THIS SECTION IS DESTROYED, SUBSTANTIALLY DAMAGED, OR DIES AS A RESULT OF NEGLIGENCE ON THE PART OF THE PROPERTY OWNER WITHIN THREE YEARS AFTER COMPLETION OF CONSTRUCTION, THEN REPLACEMENT TREES SHALL BE PLANTED ON THE SITE WITH A TOTAL DIAMETER EQUAL TO TWICE THE DIAMETER OF THE RETAINED TREE. A MINIMUM GROWING AREA OF 144 SQUARE FEET SHALL BE PROVIDED FOR EACH REPLACEMENT TREE. IF THE PLANNING DIRECTOR DETERMINES IT IS INFEASIBLE OR FOR REPLACEMENT TREE(S) TO BE ACCOMMODATED ON THE SITE, THEN A PAYMENT 0$<%(0$'(727+(&2817<¶675((,03529(0(17)81'(48,9$/(17727+( PRICING STANDARDS IN THE COUNTY FEE SCHEDULE. 60'30'15'30'0' Scale: 1"=30' MITIGATION REQUIRED FOR REMOVAL OF SIGNIFICANT TREES QTY SIZE TYPE REPLACEMENT INCHES 2 36"PINE 144.00 1 28"PINE 56.00 1 26"OAK 52.00 TOTAL REPLACEMENT INCHES 252 CREDITS FOR PRESERVED TREES QTY DBH INCHES TYPE DOCUMENTED INCHES SIGNIFICANT INCHES CREDITS 1 26"PINE 26 0.00 1 24"PECAN 24 0.00 1 36"OAK 36 0.00 1 21"OAK 21 0.00 1 18"OAK 18 0.00 1 15"OAK 15 22.50 2 12"OAK 24 36.00 1 11"OAK 11 16.50 1 8"OAK 8 12.00 1 16"PINE 16 24.00 TOTAL INCHES PRESERVED TREES 74 39 TOTAL CREDITS FOR PRESERVED TREES 111.0 22 8' S I D E W A L K 15 EXIT ONLY - ONE WAY 24 ' 18' 24' R25' 18' STAIR STAIR 10' X 70' NCDOT SIGHT TRIANGLE (TYP.) 15' 10 ' 395 510 430 460 515 37.5' 10 ' ( T Y P ) 18' (TYP) 9' 9' 9' MH 25' 25 ' P U B L I C U T I L I T Y E A S E M E N T DB . 4 3 1 8 / P G . 0 3 1 3 12.5' 430 24 ' R30 ' R 3 0 ' R 2 5 ' 10' X 70' NCDOT SIGHT TRIANGLE (TYP.) R 2 5 ' R25 ' 24 ' 15 6' SIDEWALK 24 PECAN INV.15.66' INV.15.60' 24 " R C P <= 1 5 " R C P INV. OUT=13.45' INV.IN=15.35' <= 1 8 " R C P SE W E R L I N E = > INV.OUT=14.67' (N) INV.IN=14.74' (S) RIM=17.52' SSMH D/W GRAV. D/W CONC. T T T CA S T L E H A Y N E R O A D 10 0 ' P U B L I C R I G H T - O F - W A Y N. C . H W Y 1 3 3 n/f CIRCLE K STORES INC BK 6634, PG 1085 Zoning: B-2 Use: VACANT n/f JEFFREY SUTTON HEIRS ETAL BK 9908, PG 0318 Zoning: B-2 Use: COMMERCIAL n/f TONI L SUTTON BK 5240, PG 0048 Zoning: B-2 Use: COMMERCIAL n/f MCCLURE MEMORIAL PRESBYTERIAN BK 1708, PG 0544 Zoning: B-2 Use: CHURCH n/f NEFTALI BALDERAMA GARCIA BK 6283, PG 2899 Zoning: RA Use: Single Family Residence n/f HILLSBOROUGH STREET LLC BK 6472, PG 1344 Zoning: B-2 Use: COMMERCIAL n/f CAROLINE L. BORDEAUX BK 3665, PG 0818 Zoning: RA Use: Single Family Residence n/f SIMON P PARKIN BK 1536, PG 2092 Zoning: B-2 Use: Single Family Residence 13 14 14 14 14 14 14 14 16 16 16 16 16 16 16 1 6 1 6 1 6 16 16 17 17 17 17 17 17 17 17 17 17 1 7 17 17 17 17 17 17 17 1 8 1 8 1 8 18 18 1 8 18 1 8 18 18 18 19 19 19 1 9 21 2 1 21 21 22 22 2 2 15 15 15 15 15 15 15 15 15 15 15 20 20 2 0 6" SSCO (TYP) 6" S S S E R V I C E @ 1 . 0 % M I N . 37.5' PROP. BYPASS STRUCTURE (SEE DETAIL) (1) 8"X6" TEE (1) 6" DELINEATION VALVE LOCATED 18" INSIDE R/W (1) 6" C-900 PVC PRIVATE FIRE LINE (1) 6" WATTS MODEL# LF957 RPDA  ƒ%(1'6 (1) 8"G.V. 2" WATER SERVICE (36" MIN. BURY) R 2 5 ' 8" FIRE SERVICE (36" MIN. BURY) (1) F.H. ASSY F.D.C. LOCATED ON CORNER OF BUILDING PROP. PUBLIC U.E. 10' PPES PPES RC P PPESPPES RCP R25 ' RCP EXISTING BUILDING C-1 2 PR E L I M I N A R Y S I T E P L A N 1" = 30' SITE DATA PARCEL ID:R01109-001-001-000 CURRENT ZONING:B-2 PROJECT ADDRESS:5901 CASTLE HAYNE RD. CASTLE HAYNE, NC 28429 CURRENT OWNER:REAGAN LLC 303 FOX LAKE DR. CLINTON, NC 28328 TOTAL ACREAGE IN PROJECT BOUNDARY 6) “DF PROPOSED USE:RETAIL (1st Floor) & GENERAL OFFICE (2nd Floor) BUILDING SIZE:26,400 S.F. GFA TOTAL (13,200 S.F. FOOTPRINT) BUILDING HEIGHT:6725<“ CALCULATION FOR BUILDING COVERAGE: PROPOSED COVERAGE 6)·6)  BUILDING SETBACKS: FRONT:REQUIRED= 25'PROPOSED= 79' SIDE:REQUIRED= 0' Interior/25' Street PROPOSED= 67' / 26' REAR:REQUIRED= 35' To Res. Use PROPOSED= 36' PROPOSED IMPERVIOUS AREAS: BUILDINGS 13,200 S.F. ASPHALT PARKING/DRIVE AREA 27,520 S.F. CONCRETE SIDEWALK, C.&G., ETC. 5,385 S.F. FUTURE 3,895 S.F. TOTAL 50,000 S.F (66.0%) PARKING REQUIRED: RETAIL SALES USE: (2.5/1,000 sf ) 13,200 SF/1000*2.5 = 33 SPACES GENERAL OFFICE USE: (2.5/1,000 sf ) 13,200 SF/1000*2.5 = 33 SPACES TOTAL PARKING REQUIRED:66 SPACES (3 ADA) PARKING PROVIDED:66 SPACES (3 ADA) PARKING LOT INTERIOR LANDSCAPING REQUIRED 27,520 S.F. * 8% 2,202 S.F. PROVIDED 2,740 S.F. FOUNDATION PLANTINGS: NORTH FACADE: 60 LF X 20' FACADE X 12% REQUIRED:144 S.F. PROVIDED:255 S.F. EAST FACADE: 220 LF X 20' FACADE X 12% REQUIRED:528 S.F. PROVIDED:580 S.F. STREETYARD CASTLE HAYNE RD.: (25 S.F./LF FRONTAGE. 12.5' MIN./37.5' MAX. WIDTHS) 330 LF FRONTAGE 330- 25 LF DRIVEWAY = 305 LF FRONTAGE REQUIRED: 25' X 305 LF 7,625 S.F. PROVIDED:7,758 S.F. STREETYARD LYNN AVE.: (12.5 S.F./LF FRONTAGE. 6.25' MIN./18.75' MAX. WIDTHS) 175 LF FRONTAGE 175- 19 LF DRIVEWAY = 156 LF FRONTAGE REQUIRED: 12.5' X 156 LF 1,950 S.F. PROVIDED:2,030 S.F. EXISTING SEWER AND WATER DEMAND: 0 GPD PROPOSED SEWER AND WATER DEMAND: 2,420 GPD ESTIMATED TRIP GENERATION (Per Trip Generation Manual): 13,200 SF RETAIL SHOPPING CENTER (ITE CODE 820) AM PEAK: 13 PM PEAK: 49 DAILY: 567 13,200 SF GENERAL OFFICE (ITE CODE 710) AM PEAK: 20 PM PEAK: 19 DAILY: 143 PROJECT TOTAL: AM PEAK: 33 PM PEAK: 68 DAILY: 710 REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): 2024-007 CLIENT INFORMATION: Reagan, LLC 303 Fox Lake Dr. Clinton, NC 28328 OF 7 JAE CDC CDC 24x36 8/29/2024 RE A G A N R E T A I L A N D OF F I C E C E N T E R SITE BLU E C L A Y R D NORTH KERR AVE NORTH KERR AVE O L D W R I G H T S B O R O R D AC O R N B R A N C H R D S R 1 3 1 9 SR 1 3 7 0 PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N SITE U S 4 2 1 B E A C H R D NC 1 3 2 S C O L L E G E R D MA S O N B O R O PIN E R R D GR O V E R D US 4 2 1 MY R T L E LO O P R D C A R O L I N A SITE CA S T L E H A Y N E R D LYNN AVE. CASTLE AVE. SITE CA S T L E H A Y N E R D LYNN AVE. CASTLE AVE. SITE CA S T L E H A Y N E R D CASTLE AVE. HOLLY SHELTER R D . DEVELOPMENT NOTES: 1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY LAND DEVELOPMENT CODE. 2. PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS. 3. NO SIGNS ARE PROPOSED AT THIS TIME. ANY FUTURE PROPOSED SIGN IS SUBJECT TO SECTION 5.6. OF THE UDO. 4. RUNOFF FROM ALL IMPERVIOUS SURFACES, INCLUDING ROOF DRAINS, TO BE DIRECTED TO PROPOSED UNDERGROUND INFILTRATION SYSTEM. FIRE & SAFETY NOTES: 1. CONSTRUCTION TYPE: II-B (COMMERCIAL) 2. PROPOSED BUILDING TO BE SPRINKLED. 3. CONTRACTOR SHALL MAINTAIN AN ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES DURING CONSTRUCTION. 4. BUILDING INFORMATION SIGNS MUST BE PROVIDED IN ACCORDANCE WITH THE "2018 NC FIRE CODE APPENDIX J" REQUIREMENTS. 5.CONTRACTOR SHALL SUBMIT A RADIO SIGNAL STRENGTH STUDY FOR ALL COMMERCIAL BUILDINGS THAT DEMONSTRATES THAT EXISTING EMERGENCY RESPONDER RADIO SIGNAL LEVELS MEET THE REQUIREMENTS OF SECTION 510 OF THE 2018 NC FIRE CODE. 6. ANY DRIVEWAY GATE TO BE SIREN ACTIVATED AND HAVE KNOX KEY OVERRIDE. 7.ALL FIRE HYDRANTS MUST BE INSTALLED WITH 5 INCH STORZ QUICK CONNECTS ON A 4.5 INCH STEAMER IN COMPLIANCE WITH NHC FIRE SERVICE REQUIREMENTS. 8. NO OBSTRUCTIONS WITHIN 36" AROUND A FIRE HYDRANT, INCLUDING BUT NOT LIMITED TO, STREET SIGNS, LANDSCAPING AND UTILITY POLES AND BOXES. 9. NEW HYDRANTS MUST BE BROUGHT INTO SERVICE PRIOR TO COMBUSTIBLE MATERIALS DELIVERED TO THE JOB SITE. 10. FIRE APPARATUS ACCESS ROADS SHALL PROVIDE A CLEAR VERTICAL CLEARANCE OF 14 FEET INCLUDING TREES, CANOPIES, BRIDGES, ETC. 11. DURING CONSTRUCTION, PREMISES IDENTIFICATION IS REQUIRED, AND MAY BE TEMPORARY IN NATURE PROVIDED IT IS LEGIBLE AND WEATHER RESISTANT. 12. PREMISES IDENTIFICATION IS REQUIRED. ADDRESS NUMBERS ARE REQUIRED ON THE STREET SIDE. NUMBERS 6+$//127%(/(667+$1,1&+(67$//$1'ô,1&+(6:,'(0867%(:($7+(55(6,67$17$1'&2175$67 IN COLOR AGAINST THEIR BACKGROUND. PROPERTY LINE RIGHT OF WAY EXISTING EDGE OF PAVEMENT EASEMENT PROPOSED WATERLINE PROPOSED FIRE LINE PROPOSED SANITARY SEWER LINE RUNOFF DIRECTION SPOT ELEVATION PARKING LOT LANDSCAPING STREETYARD LANDSCAPING FOUNDATION PLANTINGS LEGEND 25.5 60'30'15'30'0' Scale: 1"=30' UTILITY NOTES: 1. EXISTING WATER AND SANITARY SEWER SERVICES ARE CURRENTLY AVAILABLE TO THE SITE FROM CAPE FEAR PUBLIC UTILITY AUTHORITY PUBLIC MAINS. 2. ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS & TELEPHONE SHALL BE INSTALLED UNDERGROUND. 3. ALL WATER & SEWER UTILITIES TO BE INSTALLED PER CFPUA TECHNICAL SPECIFICATIONS & STANDARDS. 4. PROJECT SHALL COMPLY WITH CFPUA CROSS CONNECTION CONTROL REQUIREMENTS. WATER METER(S) CANNOT BE RELEASED UNTIL ALL REQUIREMENTS ARE MET AND N.C.D.E.N.R. HAS ISSUED THEIR "FINAL APPROVAL.". CALL 332-6558 FOR INFORMATION. 5. ANY BACKFLOW PREVENTION DEVICES REQUIRED BY THE CFPUA WILL NEED TO BE ON THE LIST OF APPROVED DEVICES BY USCFCCCHR OR ASSE. 6. IF CONTRACTOR DESIRES CFPUA WATER FOR CONSTRUCTION, HE SHALL APPLY IN ADVANCE FOR THIS SERVICE AND MUST PROVIDE A REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTION DEVICE ON THE DEVELOPER'S SIDE OF THE WATER METER BOX. 7. WHEN PVC WATER MAINS AND SERVICES ARE PROPOSED, THE PIPES ARE TO BE MARKED WITH NO. 10 INSULATED, SINGLE-STRAND COPPER WIRE INSTALLED & STRAPPED TO THE PIPES WITH DUCT TAPE. THIS IS TO BE ACCESSIBLE IN ALL VALVES AND METER BOXES TO AID IN FUTURE LOCATION OF FACILITIES. 8. SEWER GUARDS REQUIRED AT ALL MANHOLES. STAINLESS STEEL SEWER GUARDS REQUIRED AT MANHOLES LOCATED IN TRAFFIC AREAS. 9. SERVICES SHALL BE PERPENDICULAR TO MAIN AND TERMINATE AT RIGHT-OF-WAY LINE. SERVICES IN CUL-DE-SACS ARE REQUIRED TO BE PERPENDICULAR OR MUST ORIGINATE IN MANHOLE AND TERMINATE AT RIGHT-OF-WAY LINE. 10. ALL SERVICES TYING INTO DUCTILE IRON MAINS SHALL BE CONSTRUCTED OF CLASS 50 D.I.P. WITH PROTECTO 401 CERAMIC EPOXY LINING. 11. MINIMUM 10' UTILITIES EASEMENT PROVIDED ALONG THE FRONTAGE OF ALL LOTS AND AS SHOWN FOR NEW DEVELOPMENTS. 12. NO FLEXIBLE COUPLINGS SHALL BE USED. 13. ALL STAINLESS STEEL FASTENERS SHALL BE 316. 14. THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIES DURING CONSTRUCTION. CALL NC811 AT 811 OR 1-800-632-4949. CONTRACTOR IS RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ANY UTILITIES, CURB & GUTTER, PAVEMENT, ETC. THAT MAY BE BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIRED TO AT LEAST THE QUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM. 15. THE PROCESS FOR TELEPHONE CABLE PLACEMENT: * FINAL GRADE WILL NEED TO BE ESTABLISHED. * POWER WILL PLACE THEIR CABLE FIRST - APPROXIMATELY 3' DEEP. * BELLSOUTH & CABLE TV WILL THEN PLACE THEIR CABLE AT APPROXIMATELY 2' DEEP. 16. 3' SEPARATION BETWEEN JOINTS, FITTINGS, SERVICE SADDLES AND WYES ARE REQUIRED FOR SS AND WATER TAPS. 17. ANY EXISTING SEWER AND WATER SERVICES NOT BEING UTILIZED ARE TO BE ABANDONED TO THE MAIN PER CFPUA STANDARDS. 18. SOLID WASTE DISPOSAL IS BY PRIVATE DUMPSTER SERVICE. C-3 4 DE T A I L S NTS REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): 2024-007 CLIENT INFORMATION: Reagan, LLC 303 Fox Lake Dr. Clinton, NC 28328 OF 7 JAE CDC CDC 24x36 8/29/2024 RE A G A N R E T A I L A N D OF F I C E C E N T E R SITE BLU E C L A Y R D NORTH KERR AVE NORTH KERR AVE O L D W R I G H T S B O R O R D AC O R N B R A N C H R D S R 1 3 1 9 SR 1 3 7 0 PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N SITE U S 4 2 1 B E A C H R D NC 1 3 2 S C O L L E G E R D MA S O N B O R O PI N E R R D GR O V E R D US 4 2 1 MY R T L E LO O P R D C A R O L I N A SITE CA S T L E H A Y N E R D LYNN AVE. CASTLE AVE. SITE CA S T L E H A Y N E R D LYNN AVE. CASTLE AVE. SITE CA S T L E H A Y N E R D CASTLE AVE. HOLLY SHELTER R D . SITE WORK NOTES: 1.THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS BOTH ON AND ADJACENT TO THE SITE. 2.CLEARING: CONTRACTOR SHALL REMOVE ALL TREES AND VEGETATION WITHIN LIMITS OF CONSTRUCTION UNLESS OTHERWISE DESIGNATED TO REMAIN. 3.GRUBBING AND STRIPPING: CONTRACTOR SHALL RAKE AND REMOVE ROOTS, STUMPS, VEGETATION, DEBRIS, EXISTING STRUCTURES ABOVE AND BELOW GRADE, ORGANIC MATERIAL OR ANY OTHER UNSUITABLE MATERIAL WITHIN LIMITS OF CONSTRUCTION. 4.MUCKING: CONTRACTOR SHALL COORDINATE WITH OWNER AND THEIR GEOTECHNICAL REPRESENTATIVE TO COORDINATE REMOVAL OF ANY SOFT AREAS. 5.DISPOSAL: CLEARED, GRUBBED, STRIPPED OR OTHER WASTE MATERIAL SHALL BE REMOVED FROM SITE AND DISPOSED OF IN A PROPERLY PERMITTED FACILITY. 6.FILL AND COMPACTION SHOULD COMPLY WITH GEOTECHNICAL RECOMMENDATIONS. 7.THE CONTRACTOR SHALL NOTE THAT THE GRADING PLAN MAY NOT REPRESENT A BALANCED EARTHWORK CONDITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CUT AND FILL QUANTITIES AND COMPLETE INSTALLATION TO SPECIFIED GRADES. 8.THE CONTRACTOR SHALL FURNISH SUITABLE BORROW MATERIAL FROM AN OFF-SITE PROPERLY PERMITTED FACILITY AS REQUIRED. 9.INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXACT ELEVATIONS AND LOCATIONS OF ALL EXISTING UTILITIES AT ALL CROSSINGS PRIOR TO COMMENCING TRENCH EXCAVATION. IF ACTUAL CLEARANCES ARE LESS THAN INDICATED ON PLAN, THE CONTRACTOR SHALL CONTACT THE DESIGN ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. ANY CONDITION DISCOVERED OR EXISTING THAT WOULD NECESSITATE A MODIFICATION OF THESE PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. 10.NO CONSTRUCTION IS TO BEGIN BEFORE LOCATION OF EXISTING UTILITIES HAS BEEN DETERMINED. CALL "NC ONE-CALL" AT LEAST 48 HOURS BEFORE COMMENCING CONSTRUCTION. 11.THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES DURING CONSTRUCTION. BEFORE COMMENCING ANY EXCAVATIONS IN OR ALONG ROADWAYS OR RIGHT-OF-WAYS, PUBLIC AREAS OR IN PRIVATE EASEMENTS, THE CONTRACTOR SHALL NOTIFY ALL APPROPRIATE PERSONNEL OF THEIR INTENT TO EXCAVATE, IN WRITING, NOT LESS THAN 10 DAYS PRIOR TO EXCAVATING. 12.THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE DISCONNECTION/ RECONNECTION AND/OR THE RELOCATION OF ALL EXISTING UTILITIES WITH APPROPRIATE PERSONNEL. 13.CONTRACTOR SHALL ADJUST ALL MANHOLES, VALVE & CURB BOXES TO FINAL GRADE UPON COMPLETION OF ALL CONSTRUCTION. ANY BOXES DAMAGED OR OTHERWISE DISTURBED BY THE CONTRACTOR SHALL BE REPAIRED AT THE EXPENSE OF THE CONTRACTOR. 14.THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AT THE SITE. FURTHERMORE THE CONTRACTOR SHALL REPORT ALL DISCREPANCIES OR QUESTIONS TO THE ENGINEER PRIOR TO INSTALLATION. 15.THE CONTRACTOR SHALL PROVIDE ANY AND ALL LAYOUT REQUIRED TO CONSTRUCT HIS WORK UNLESS OTHERWISE DIRECTED BY OWNER. 16.ALL SERVICE CONNECTIONS SHALL BE INSTALLED TO MEET ALL LOCAL, STATE, AND CFPUA CODES. METERS, TAPS, MATERIALS, WORKMANSHIP AND ALL FEES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL COMPLY WITH ALL REQUIREMENTS. 17.ALL BACKFILL FROM UTILITY INSTALLATION MUST BE COMPACTED OR AMENDED TO PROVIDE TRAFFIC BEARING CAPACITY. GEOTECHNICAL ENGINEER TO BE CONSULTED AT CONTRACTORS COST AS NECESSARY. 18.ALL AREAS SHALL BE GRADED FOR POSITIVE DRAINAGE. CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO INSTALLATION. ALL AREAS SHALL BE SLOPED TO DRAIN AWAY FROM BUILDINGS AT ALL TIMES. 19.CONCRETE FOR WALKS, CURBS AND DRIVES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI @ 28 DAYS - AIR ENTRAINED. 20.FIELD TESTING SHALL BE DONE BY AN INDEPENDENT TESTING LABORATORY PAID FOR BY THE OWNER. FURTHER TESTING REQUIRED DUE TO A FAILED TEST WILL BE PAID FOR BY THE CONTRACTOR. 21.ALL SIDEWALKS SHALL BE FREE OF CRACKS, BREAKS, OR ANY OTHER DEFECT PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. 8" CONCRETE PAD W/CROSS-BRACING ENCLOSURE GATES 6X6 - 6/6 W.W.F. AT 3000 PSI W/ WOOD SIDING HORIZONTAL (TREATED) 4"X4" POSTS FOOTINGS CONCRETE 2"X6" CAP PAVEMENT ASPHALT 10' 4"X4" POSTS DUMPSTER PAD & ENCLOSURE DETAIL ELEVATIONS PLAN NTS PROPOSED DRIVEWAY GRADE 2% MIN SLOPE 6' MIN FROM EX. EOP TYPICAL DRIVEWAY GRADING SECTION NTS (;52$'“6/23( NTS 2" SF9.5A 8" ABC PAVEMENT SECTION COMPACTED SUBGRADE1-1/2"R(TYP) WHITE SYMBOL ON BLUE BACKGROUND LEGEND AND BORDER - GREENBACKGROUND - WHITE 12" 3/8"(TYP) LEGEND AND BORDER - GREEN BACKGROUND - WHITE 12" COLORS 1-1/2"R(TYP) LEGEND AND BORDER - GREENBACKGROUND - WHITE 18" 3/8"(TYP) TO READ "VAN ACCESSIBLE". BOLT TO WD. POST WITH 3/8" CANDIUM PLATED NUTS, BOLTS & WASHERS 9" x 1'-6" x .080 STD ALUM. SIGN NUTS, BOLTS & WASHERS. 9" x 1'-0" x .080 STD ALUM. SIGN TO READ "MAXIMUM PENALTY $250, GS 20-37.6". BOLT TO WD. POST WITH 3/8" CANDIUM PLATED PRESSURE TREATED 4"x4" POST. FINISHEDGRADE HANDICAPPED PARKING SIGN WITH IDENTIFICATION SYMBOL. 1'-6" x 1'-0" x .080 STD. ALUM. TO READ "RESERVED PARKING" BOLT TO WD. POST W/ 3/8" CANDIUM PLATED NUTS, BOLTS & WASHERS. TYPICAL HANDICAPPED SIGN DETAIL NTS R7-8a Sign (no arrows) R7-8d Sign R7-8P Sign MIN. 12-1/2 GA. INTERMEDIATE WIRES SHALL HAVE A MIN. OF SIX LINE WIRES WITH 12" STAY 36" IN WIDTH. FABRIC SHALL BE FASTENED SELF-FASTENER STEEL ANGLE TYPE. 1. FENCE FABRIC SHALL BE A MIN. OF 32" IN WIDTH AND 2. FABRIC SHALL BE FOR EROSION CONTROL AND MIN. OF ADEQUATELY TO THE WIRE FABRIC AS DIRECTED BY THE 3. STEEL POST SHALL BE 5'-0" IN HEIGHT AND BE OF THE TEMPORARY SILT FENCE NTS SPACING. ENGINEER. NOTES: VARIES (6'-8' MIN.) AS DIR. BY ENG. STEEL POST FI L T E R F A B R I C WIRE FABRIC FILTER FABRIC 4" 8"6" ANCHOR FABRIC SKIRT AS DIRECTED BY ENGINEER TEMPORARY GRAVEL CONSTRUCTION ENTRANCE NTS PUB L I C R O A D COARSE AGGREGATE 2" - 3" 6" MIN.REQ U I R E D AS 50' M I N . 12' M I N . GEO FABRIC LINER CONSTRUCTION ENTRANCE TO BE 12' OR ENTIRE WIDTH OF NOTE: ENTRANCE. WHICHEVER IS GREATER. HARDWARE CLOTH AND GRAVEL INLET PROTECTION NTS 4' MAX. NCDOT #5 OR # 57 WASHED STONE 19-GAUGE HARDWARE CLOTH (1/4 MESH OPENINGS) FILTERED WATER INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (12 INCH OR GREATER) RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER OBJECTS TO PROVIDE ADEQUATE FLOW FOR SUBSEQUENT RAINS. TAKE CARE NOT TO DAMAGE OR UNDERCUT THE WIRE MESH DURING SEDIMENT REMOVAL. REPLACE STONE AS NEEDED. MAINTENANCE: CONSTRUCTION SPECIFICATIONS: 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. 2. DRIVE 5-FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING THE INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET APART. 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE, AND BOTTOM. PLACINGA 2-FOOT FLAP OF WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS RECOMMENDED. 4. PLACE CLEAN GRAVEL (NCDOT #5 OR #57 STONE) ON A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES AROUND THE WIRE, AND SMOOTH TO AN EVEN GRADE. 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ACCUMULATED SEDIMENT, AND ESTABLISH FINAL GRADING ELEVATIONS. 6. COMPACT THE AREA PROPERLY AND STABILIZED IT WITH GROUNDCOVER. 4" CONC. SIDEWALK w/6x6-10/10 W.W.M. 4"8" x x x x x ASPHALT TURNDOWN SIDEWALK NTS CLASS A CONC. 7"1/8"R 1"3"R 6" 1 1/2"R 3"R 1' - 0 " 2'-0" 1'-6"6" ASPHALT DRAINAGE AWAY FROM CURB CLASS A CONC. 24" CURB SECTION NTS ASPHALT 7" 2'-0" 3"R 1'-6" 1/8"R 1" 6" 6" 1' - 0 " DRAINAGE TOWARD CURB SHALL SLOPE AWAY AS SHOWN AWAY FROM CURB, GUTTER WHERE RUNOFF IS DIRECTED SLOPE SLOPE 1 1/2"R 3"R SIDEWALK SECTION A-A 4' min SECTION B-B A A B B “1.0-8.3% (30"MAX RISE) 10% MAX (X=36"MIN) 8.3% MAX (X<36") (FOR ALTERATIONS RAMP CURB AND GUTTER WARNING DOMES 2' MIN 1.6-2.4" (TYP) RAMP WIDTH 0.2" Flare WARNING DOMES 4' FLARE 2. 1.6-2.4" (TYP) TRUNCATED DOMES BASE DIAMETER 0.9-1.4" TOP DIAMETER 50-60% OF BASE (TYP) LANDING NTS WHEEL CHAIR RAMP DETAIL