Loading...
HomeMy WebLinkAboutD-1387-SP RF551US H W Y 1 3 3 - C A S T L E H A Y N E R O A D N O R T H 2 3 r d S T R E E T STORMWATER MANAGEMENT AREA 95'-4" 40 ' 47.6' 58 . 2 ' 27.7' 46 ' 42 ' 30' 9' 20 ' 8'8'8' 20 ' 9' R3' R30 ' 30' 30' R 3 ' R 3 0 ' R2 8 ' R8' R3' R 3 ' R30' R28 ' R 2 2 ' 108' 117' R3 0 ' R 3 2 ' ROYAL FARMS TYPE LEANCON (LEFT) 4,710 S.F. 36 ' R25' R8 ' 44 . 0 4 ' 48' 88.94' BEGINNING OF JURISDICTIONAL STREAM LAT. 34.27199°, LON. -77.92680° (N 191735.1, E 2324244.9 US FT) IN ACCORDANCE WITH STREAM DETERMINATION DWR 2023-004. 20'X24' CONCRETE DUMPSTER PAD W/FENCED ENCLOSURE VA H/C SIGN TRUNCATED DOMES (TYPICAL) H/C SIGN UNDERGROUND STORAGE TANKS (TYPICAL) FUEL TANK LANDING PAD FUEL DISPENSER ISLAND (TYPICAL) DIRECTIONAL SIGN DIRECTIONAL SIGN EXISTING TOP OF BANK PRIMARY SIGN (50 SQ.FT. MAX AREA) (20'-0" MAX HEIGHT) PRIMARY SIGN (50 SQ.FT. MAX AREA) (20'-0" MAX HEIGHT) SITE LIGHTING (TYPICAL) NEW TOP OF BANKAREA OF IMPACTED STREAM (1,873 SQ.FT.) 30'± 30' VEGETATED SETBACK 17.5' 35'-0" PUBLIC DRAINAGE EASEMENT CENTERED ON STREAM CENTERLINE 35'± LEGEND EXISTING PROPOSED TA=X.XX TC=X.XX BC=X.XX WM GMGV CO GR I D 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S Site Data TOTAL ACREAGE IN SITE:2.40± AC TOTAL ACREAGE IN PROJECT LIMITS:3.05± AC DISTURBED ACREAGE:3.05± AC CURRENT ZONING:B-1 (NEIGHBORHOOD BUSINESS) PROPOSED USE:CONVENIENCE STORE / FUEL STATION PARCEL ID:R04100-003-007-000 LAND USE CLASSIFICATION:528-NEIGHBORHOOD RETAIL GROSS FLOOR AREA:4,710 SF BUILDING LOT COVERAGE:17.2% EXIST., 3.0% PROPOSED BUILDING HEIGHT:21'-9" TOP OF PARAPET (1 STORY) 32'-5" TOP OF GABLE 38'-5" TOP OF CUPOLA TOTAL SQ. FEET OF EXIST. IMPERVIOUS AREA:54,268.16 SF TOTAL SQ. FEET OF PROP. IMPERVIOUS AREA:52,326.91 SF REFERENCES:D.B. 644, PG. 1326 ADDRESS:1824 CASTLE HAYNE ROAD WILMINGTON, NC 28401 Vicinity Map SCALE: 1" = 1000' As-Built Survey Note: A SURVEY FOR THE AS-BUILT PLANS MUST BE COMPLETED BY A LAND SURVEYOR REGISTERED IN THE STATE OF NORTH CAROLINA AND CONFIRMED THE AS-BUILT PLAN MEET THE DESIGN REQUIREMENTS BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF NORTH CAROLINA. THE SURVEY SHALL INCLUDE REQUIRED AND AS-BUILT ELEVATIONS OF THE BASIN BOTTOM, ORIFICE, WEIR, TOP OF EMBANKMENT AND SPILLWAY. Survey Note: BOUNDARY AND TOPOGRAPHIC INFORMATION SHOWN HEREON WAS PREPARED BY ENCOMPASS, PLLC, AS SHOWN ON DRAWING ENTITLED "ALTA/NSPS LAND TITLE SURVEY OF PROPERTY OWNED BY ARK-ROYAL FARMS STORE #551" CASTLE HAYNE ROAD/N 23RD STREET, NEW HANOVER COUNTY, N.C., DATED OCTOBER 14, 2022, ATTACHED TO THIS DRAWING SET FOR REFERENCE. Parking Requirements: Sheet Index #Title C1.0 Site Plan / Cover C1.1 Future Roadway Improvements Plan C1.2 Road Widening Plan C2.0 Demolition & Ph 1 Erosion Control Plan C2.1 Demolition & Ph 2 Erosion Control Plan C3.0 Grading Plan C4.0 Utility Plan C6.0 - C6.5 Details C7.0 - C7.4 Details C8.0 - C8.2 Details REF Survey - Encompass, PLLC (1 sheet) L1 - L2 Landscaping Plan Engineer Landowner / Developer Two Farms Inc. 3611 Roland Ave. Baltimore, MD 21211 (410)889-0200 Contact: Chris Bollino realestate@royalfarms.comKNOW WHAT'S BELOW CALL BEFORE YOU DIG! 1-800-632-4949 WWW.NC811.ORG R C1.0 SI T E P L A N 0 SCALE 1 inch = ft 30' 30 30'15' PARKING REQUIRED:AUTOMOTIVE FUEL SALES & CONVENIENCE STORE RETAIL CONVENIENCE STORE: 5,154 SF @ 2.5 SPACE / 1,000 SF 13 SPACES FUEL SALES: 5,154 SF @ 1.5 SPACE / 1,000 SF 8 SPACES TOTAL REQUIRED PARKING:21 SPACES TOTAL PARKING PROVIDED:40 SPACES Ark Consulting Group, PLLC 2755 Charles Blvd - Suite B Greenville, NC 27858 (252) 565-1017 Contact:Kenneth Judy, PE Kenneth.Judy@arkconsultinggroup.com SITE General Notes: 1.CONTACT NORTH CAROLINA ONE-CALL CENTER, INC. (NC ONE-CALL) AT 811 TO HAVE ALL UNDERGROUND UTILITIES LOCATED PRIOR TO EXCAVATING OR TRENCHING. 2.ALL REQUIRED IMPROVEMENTS SHALL CONFORM TO NEW HANOVER COUNTY STANDARDS. 3.ALL REQUIRED UTILITY IMPROVEMENTS SHALL CONFORM TO CAPE FEAR UTILITY AUTHORITY MATERIAL SPECIFICATIONS MANUAL, TECHNICAL SPECIFICATIONS FOR CONSTRUCTION, AND STANDARD DRAWING DETAILS. 4.THIS PROPERTY IS LOCATED IN FLOOD ZONE X (AREA DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOOD PLAIN), ZONE X SHADED AS SHOWN ON THE FEMA FLOOD INSURANCE RATE MAP NUMBER 3720312900K, EFFECTIVE AUGUST 28, 2018. 5.ELECTRIC AND TELEPHONE UTILITIES SHALL BE INSTALLED UNDERGROUND. 6.PAVEMENT SECTIONS ARE AS INDICATED ON PLAN SHEET C-5. 7.PROVIDE ALL NECESSARY SIGNAGE FOR HANDICAP PARKING. 8.PARKING LOT SHALL BE STRIPED IN ACCORDANCE WITH PLAN. 9.REFER TO ARCHITECTURAL PLANS FOR BUILDING DIMENSIONS. 10.REFER TO M.E.P. PLANS FOR COORDINATION OF BUILDING UTILITY SERVICES. 11.CONTRACTOR SHALL STOCKPILE TOPSOIL FOR USE IN LANDSCAPE AREAS. 12.STORMWATER MANAGEMENT FOR THIS SITE IS REQUIRED. 13.THIS PROJECT DISTURBS MORE THAN 1 ACRE. EROSION CONTROL PLAN APPROVAL IS REQUIRED. 14.ALL DIMENSIONS ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. 15.A REDUCED PRESSURE PRINCIPAL BACKFLOW DEVICE IS REQUIRED ON THE DOMESTIC WATER SERVICE. 16.SITE SHALL MEET ALL RELATED ACCESSIBILITY CODE REQUIREMENTS. 17.NEW BUILDINGS MUST COMPLY WITH NC FIRE CODE SECTION 510 - EMERGENCY RESPONDER RADIO COVERAGE. 18.THE PREMISES SHALL NOT BE USED FOR THE SALE OF VEHICLES. 19.ALL SITE SIGNAGE SHALL CONFORM TO TO SECTION 5.6 OF THE UNIFIED DEVELOPMENT ORDINANCE. 20.ALL FUELING DISPENSING AREAS SHALL COMPLY WITH ALL SIGN ORDNANCES AND CLEARLY DISPLAY ALL SAFETY SIGNAGE AND NFPA 704 SIGNAGE. 21.ALL BUILDING SIGNAGE SHALL COMPLY WITH ALL SIGN ORDNANCES AND ADHERE GUIDELINES IN APPENDIX J. 22.A SECTION 510 STUDY FOR EMERGENCY FIRST RESPONSE RADIO COVERAGE SHALL BE COMPLETED PRIOR TO CONSTRUCTION. GORDON R D BLU E C A Y R D N 2 3 R D S T CA S T L E H A Y N E R D YORKTOWN D R FOREST LN VICT O R I A D R US H W Y 1 3 3 - C A S T L E H A Y N E R O A D N O R T H 2 3 r d S T R E E T STORMWATER MANAGEMENT AREA 95'-4" 40 ' 47.6' 58 . 2 ' 27.7' ROYAL FARMS TYPE LEANCON (LEFT) 4,710 S.F. BEGINNING OF JURISDICTIONAL STREAM LAT. 34.27199°, LON. -77.92680° (N 191735.1, E 2324244.9 US FT) IN ACCORDANCE WITH STREAM DETERMINATION DWR 2023-004. APPROXIMATE LOCATION OF FUTURE NCDOT EASEMENT APPROXIMATE LOCATION OF FUTURE NCDOT RIGHT-OF-WAY APPROXIMATE LOCATION OF FUTURE CURB AND GUTTER (TYPICAL) 20'X24' CONCRETE DUMPSTER PAD W/FENCED ENCLOSURE VA H/C SIGN TRUNCATED DOMES (TYPICAL) H/C SIGN UNDERGROUND STORAGE TANKS (TYPICAL) FUEL TANK LANDING PAD FUEL DISPENSER ISLAND (TYPICAL) DIRECTIONAL SIGN DIRECTIONAL SIGN EXISTING TOP OF BANK PRIMARY SIGN (50 SQ.FT. MAX AREA) (20'-0" MAX HEIGHT) PRIMARY SIGN (50 SQ.FT. MAX AREA) (20'-0" MAX HEIGHT) SITE LIGHTING (TYPICAL) NEW TOP OF BANKAREA OF IMPACTED STREAM (1,873 SQ.FT.) 30'± 30' VEGETATED SETBACK 17.5' 35'-0" PUBLIC DRAINAGE EASEMENT CENTERED ON STREAM CENTERLINE 35'± LEGEND EXISTING PROPOSED TA=X.XX TC=X.XX BC=X.XX WM GMGV CO GR I D 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S KNOW WHAT'S BELOW CALL BEFORE YOU DIG! 1-800-632-4949 WWW.NC811.ORG R C1.1 FU T U R E R O A D W A Y I M P R O V E M E N T S P L A N 0 SCALE 1 inch = ft 30' 30 30'15' THIS SHEET SHOWS OFFSITE IMPROVEMENTS PROPOSED BY NCDOT PROJECT U-5954. IMPROVEMENTS SHOWN ARE BASED UPON 25% DESIGN PLANS PROVIDED BY DIVISION DESIGN CONSTRUCT - DIVISION THREE VIA EMAIL ON SEPTEMBER 7, 2022. IMPROVEMENTS SHOWN ARE FOR INFORMATION ONLY AND ARE SUBJECT TO CHANGE SHOULD THEIR CONSTRUCTION MOVE FORWARD. NORTH 23rd STREET SF SFSFSFSFSFSFSF SF SFSFSFSF UGE UGE UGE U G E 30 ' R3 ' R3 0 ' R3' R30' R32'R25' R 8 ' 44.04' 48 ' TEM P O R A R Y G R A V E L 100' 98.19' 12 ' 12 ' US HWY 133 - CASTLE HAYNE ROAD SFSFSF 3 0 ' R30 ' R28' R 3 0 ' R28' 36' 125.02'100.27' SF SF SF SF SF SF SF 12 ' 11 ' LEGEND EXISTING PROPOSED TA=X.XX TC=X.XX BC=X.XX WM GMGV CO GRID GRI D 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S KNOW WHAT'S BELOW CALL BEFORE YOU DIG! 1-800-632-4949 WWW.NC811.ORG R C1.2 RO A D W I D E N I N G P L A N 0 SCALE 1 inch = ft 20' 20 20'10' PROPOSED US HWY 113 / CASTLE HAYNE ROAD WIDENING AND STRIPING PLAN SCALE: 1" = 20' PROPOSED N 23RD STREET ROAD WIDENING AND STRIPING PLAN SCALE: 1" = 20' 1.CONTACT NORTH CAROLINA ONE-CALL CENTER, INC. (NC ONE-CALL) AT 811 TO HAVE ALL UNDERGROUND UTILITIES LOCATED PRIOR TO EXCAVATING OR TRENCHING. 2.CONTRACTOR SHALL NOTIFY NCDOT DIVISION OFFICE 48 HOURS PRIOR TO MAKING CONNECTIONS TO EXISTING STORM DRAINS LOCATED WITHIN PUBLIC STORM DRAINAGE EASEMENTS OR R/W. 3.NCDOT DRIVEWAY APPROVAL PERMIT REQUIRED. 4.CONTRACTOR SHALL PROVIDE AND MAINTAIN TRAFFIC CONTROL MEASURES IN ACCORDANCE WITH THE NCDOT STANDARDS, AND AS REQUIRED BY LOCAL AGENCIES WHEN WORKING IN AND/OR ALONG STREETS, ROADS, HIGHWAYS, ETC. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN APPROVAL AND COORDINATE WITH THE LOCAL AND/OR STATE AGENCIES REGARDING THE NEED, EXTENT, AND LIMITATIONS ASSOCIATED WITH INSTALLING AND MAINTAINING TRAFFIC CONTROL MEASURES. 5.THERMOPLASTIC PAVEMENT MARKINGS ARE BY OTHERS AFTER PLACEMENT OF ASPHALT SURFACE COURSE, TEMPORARY PAVEMENT MARKINGS SHALL BE BY SITE CONTRACTOR FOR TURNER RUN SUBDIVISION. 6."BC" = TOP OF BACK OF CURB ELEVATION. 7."TA" = TOP OF ASPHALT SURFACE COURSE ELEVATION. 8.EXISTING CONDITIONS AS DEPICTED ON THESE PLANS ARE GENERAL AND ILLUSTRATIVE IN NATURE AND MAY NOT INCLUDE ALL MECHANICAL, ELECTRICAL AND MISCELLANEOUS STRUCTURES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EXAMINE THE SITE AND BE FAMILIAR WITH EXISTING CONDITIONS PRIOR TO BIDDING ON THE WORK FOR THIS PROJECT. IF CONDITIONS ENCOUNTERED DURING EXAMINATION ARE SIGNIFICANTLY DIFFERENT THAN THOSE SHOWN, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY. 9.UNDERGROUND UTILITIES PLOTTED IN PART FROM ACTUAL FIELD LOCATION OF ABOVE GROUND FEATURES AND IN PART FROM MAPS ON RECORD. ACTUAL LOCATIONS MAY VARY. SURVEYOR AND ENGINEER CANNOT PROVIDE ACCURACY OF INFORMATION TAKEN FROM RECORD DATA. OTHER UTILITIES MAY EXIST. CONTRACTOR SHOULD CONTACT NORTH CAROLINA ONE-CALL CENTER (NC ONE-CALL) AT 1-800-632-4949 TO HAVE UNDERGROUND UTILITIES LOCATED PRIOR TO EXCAVATING OR TRENCHING. 10.THE ENGINEER MAKES NO GUARANTEE THAT THE UTILITIES SHOWN ARE COMPRISED OF ALL SUCH UTILITIES IN THE AREA OF SURVEY EITHER IN SERVICE OR ABANDONED. THE ENGINEER FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED. THE ENGINEER DOES HEREBY CERTIFY THAT ALL UTILITIES ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE. THE ENGINEER HAS NOT PHYSICALLY UNCOVERED AND LOCATED ANY UNDERGROUND UTILITIES. 11.THE APPLICANT / PROPERTY OWNER SHALL BE RESPONSIBLE TO PERFORM ROUTINE MAINTENANCE OF THE DRIVEWAY(S) TO ENSURE ALL APPLICABLE CONCRETE MEDIAN ISLANDS, TRAFFIC SIGNS, PAVEMENT MARKINGS AND/OR REFLECTORS REMAIN IN COMPLIANCE AS PERMITTED. 12.ALL THERMOPLASTIC PAVEMENT MARKINGS SHALL BE 90 MILS THICKNESS. 13.ALL PAVEMENT MARKINGS SHALL BE THERMOPLASTIC AND INSTALLED ACCORDING TO MOST CURRENT NCDOT STANDARDS. 14.RAISED SNOWPLOWABLE PAVEMENT MARKERS ARE TO BE USED FOR THIS PROJECT AND INSTALLED ACCORDING TO MOST CURRENT NCDOT STANDARDS. 15.REMOVE ALL CONFLICTING EXISTING PAVEMENT MARKINGS AND SIGNS WITHIN THE CONSTRUCTION AREA. 16.TIE PROPOSED PAVEMENT MARKING LINES TO EXISTING PAVEMENT MARKING LINES. 17.MINIMUM OF 36" OF COVER OVER EXISTING 8" ASBESTOS CEMENT WATER MAIN TO BE MAINTAINED. General Notes: EXISTING SUB GRADE C THERMOPLASTIC MARKING SYMBOLS NCDOT STD. 1205.08 (RIGHT TURN ARROW) B THERMOPLASTIC PAVEMENT MARKING LINES NCDOT STD. 1205.01 (4" WHITE MINI SKIP / 3'-9') A THERMOPLASTIC PAVEMENT MARKING LINES NCDOT STD. 1205.01 (4" WHITE CONTINUOUS) Pavement Marking & Sign Legend Pavement Legend: HEAVY-DUTY CONCRETE CONCRETE SIDEWALK MEDIUM DUTY ASPHALT **(DRIVE AISLES) LIGHT DUTY ASPHALT **(PARKING STALLS) NCDOT FULL DEPTH SECTION *(ROAD WIDENING) *PAVEMENT SECTION WITHIN RIGHT-OF-WAY **TYPICAL PAVEMENT SECTIONS D SIGN - STOP NCDOT STD. 904.50 (R1-1) - 30" x 30" E SIGN - RIGHT-OUT ONLY NCDOT STD. 904.50 (R3-5) - 30" x 36"E A B D C 2" ASPHALT CONCRETE (NCDOT TYPE S-9.5C SURFACE COURSE) 3" SUPERPAVE ASPHALT MIXTURE TYPE I19.0C 5" ASPHALT BASE MIXTURE TYPE B25.0C NCDOT FULL DEPTH SECTION NOT TO SCALE 36" 8" 48 " 28 " 28 " 8' - 0 " M I N . 12" 32" R=4 0 " R=2 8 " * PAVEMENT MARKING ARROWS NOT TO SCALE 6'-4" 24 " 4" 36" 8" 32 " 48 " 28 " 28 " 8' - 0 " M I N . 12" 32" R = 4 0 " R= 2 8 " * 6'-4" 24 " 4" 14" 5' - 0 " 9' - 6 " M I N . 14" 20" 12 " 12" 4' - 6 " 1.USE THE COLOR WHITE FOR ALL PAVEMENT MARKING SYMBOLS 2.DO NOT LOCATE PAVEMENT MARKING SYMBOLS AS TO ENCROACH UPON INTERSECTION AREAS. 3.DO NOT PLACE SYMBOLS ACROSS TRANSVERSE EXPANSION JOINTS; ON PORTLAND CEMENT CONCRETE PAVEMENTS UNLESS APPROVED BY THE ENGINEER. 4.CONFORM ALL SYMBOLS TO THE FHMA "STANDARD HIGHWAY SIGNS" MANUAL; WHICH INCLUDES, PAVEMENT MARKINGS AND STANDARD ALPHABETS (REFER TO SHEETS 6 THROUGH 9) DIMENSIONS MAY VARY PER MANUFACTURER, THEREFORE SLIGHT VARIANCE MAY BE ACCEPTABLE PROVIDED ALL SYMBOLS ARE APPROVED BY THE ENGINEER. PUBLIC R/W EXIST. PAVEMENT (WIDTH VARIES)PROPOSED PAVEMENT AND BASE COURSE MATCH EXISTING SLOPE CL EXIST ROAD (11' WIDTH) PROPOSED ASPHALT BASE: 5" B-25.0 C PROPOSED ASPHALT PAVEMENT: (REFER TO NCDOT FULL DEPTH SECTION) EXISTING ASPHALT SECTION MILL EXISTING ASPHALT 12" WIDE TO PROVIDE 2" THICK LAP JOINT WITH S-9.5C, INSTALL FLUSH WITH EXISTING ASPHALT 2'-6" FINISHED GRADE TYPICAL SECTION - LANE WIDENING NOT TO SCALE AB C D PUBLIC R/W EXIST. PAVEMENT (WIDTH VARIES)PROPOSED PAVEMENT AND BASE COURSE MATCH EXISTING SLOPE CL EXIST ROAD (12' WIDTH) PROPOSED ASPHALT BASE: 5" B-25.0 C PROPOSED ASPHALT PAVEMENT: (REFER TO NCDOT FULL DEPTH SECTION) EXISTING ASPHALT SECTION MILL EXISTING ASPHALT 12" WIDE TO PROVIDE 2" THICK LAP JOINT WITH S-9.5C, INSTALL FLUSH WITH EXISTING ASPHALT PAVED SHOULDER (4' WIDTH) FINISHED GRADE TYPICAL SECTION - LANE WIDENING NOT TO SCALE F AC D B F THERMOPLASTIC PAVEMENT MARKING LINES NCDOT STD.1205.01 (4" WHITE MINI SKIP / 2'-6')F G THERMOPLASTIC PAVEMENT MARKING LINES NCDOT STD.1205.01 (4" YELLOW CENTERLINE / "DOUBLE YELLOW")G F G H THERMOPLASTIC PAVEMENT MARKING LINES NCDOT STD.1205.02 (4" YELLOW CENTERLINE / "YELLOW SKIP CENTER LINES")H H LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD L O D L O D L O D L O D L O D L O D L O D L O D LOD LOD LOD LOD LOD LOD LOD LOD L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D LO D L O D L O D L O D LODLODLOD LO D L O D LO D L O D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LOD LOD LOD US H W Y 1 3 3 - C A S T L E H A Y N E R O A D N O R T H 2 3 r d S T R E E T SF S F S F S F S F SFSF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF S F S F S F S F S F S F S F PROTECT EX. UTILITIES (TYP) PROTECT EX. UTILITIES (TYP) PROTECT EX. UTILITIES (TYP) PROTECT EX. UTILITIES (TYP) PROTECT ADJOINING PROPERTY (TYP) REMOVE 18" STORM PIPE REMOVE (2) 12" STORM PIPES REMOVE 12" STORM PIPE REMOVE STORM DI POWER POLE TO BE RELOCATED (TYP) CONCRETE WASHOUT TEMPORARY GRAVEL CONSTRUCTION ENTRANCE (20'Wx50'Lx6"THICK) TREE PROTECTION AREA SF SF SF SF POWER POLE TO BE RELOCATED RELOCATE FIRE HYDRANT LEGEND EXISTING PROPOSED TA=X.XX TC=X.XX BC=X.XX WM GMGV CO GR I D 0 SCALE 1 inch = ft 30' 30 30'15' 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S KNOW WHAT'S BELOW CALL BEFORE YOU DIG! 1-800-632-4949 WWW.NC811.ORG R C2.0 DE M O L I T I O N & P H A S E 1 E R O S I O N C O N T R O L P L A N Construction Sequence: CONTRACTOR MUST SCHEDULE A PRE-CONSTRUCITON MEETING WITH THE EROSION CONTROL INSPECTOR PRIOR TO INITIATING ANY LAND DISTURBING ACTIVITY. 1.INSTAL ALL PERIMETER CONTROL DEVICES, INCLUDING PIPE INLET PROTECTION ON THE DOWNSTREAM CULVERT, SILT FENCING, AND TEMPORARY CONSTRUCTION ENTRANCE. 2.CLEAR AND GRUB THE SITE. 3.STRIP AND STOCKPILE TOPSOIL. 4.STORM DRAINAGE INSTALLATION 5.ROUGH GRADING 6.BUILDING PAD(S) INSTALLATION 7.ROUGH GRADING COMPLETION 8.UTILITY INSTALLATION 9.INSTALLATION OF CONCRETE CURB AND GUTTER 10.PLACEMENT OF STONE BASE 11.BUILDING CONSTRUCTION 12.UNDERGROUND ELECTRIC INSTALLATION 13.FINE GRADING OF PARKING LOTS 14.PLACEMENT OF CONCRETE / ASPHALT PAVEMENT 15.INSTALL PAVEMENT MARKINGS / SIGNAGE 16.INSTALL LANDSCAPING AND COMENCE SEEDING AND MULCHING NOTE: 1.MAINTAIN EROSION CONTROL MEASURES UNTIL VEGETATION IS ESTABLISHED (>80% COVERAGE) 2.REMOVE ALL EROSION CONTROL MEASURES AND VEGETATE / STABILIZE LOCATION OF PREVIOUS EROSION CONTROL MEASURES SEVERAL ITEMS LISTED ABOVE MAY BE CONSTRUCTED SIMULTANEOUSLY. AN ANTICIPATED TIME SCHEDULE OF 10 MONTHS IS EXPECTED FOR THIS PROJECT. Demolition Notes: 1.CONTRACTOR SHALL CONTACT NORTH CAROLINA ONE-CALL CENTER (NC 811) BY DIALING 811 OR 1-800-632-4949 AT LEAST 72 HOURS IN ADVANCE OF ANY LAND DISTURBING ACTIVITY OR DIGGING AND HAVE ALL UNDERGROUND UTILITIES LOCATED PRIOR TO EXCAVATING OR TRENCHING. 2.THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL LOCAL AND STATE PERMITS REQUIRED FOR DEMOLITION WORK. 3.THE CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLESS THE OWNER AND/OR ENGINEER FOR ANY AND ALL INJURIES AND/OR DAMAGES TO PERSONNEL, EQUIPMENT AND/OR EXISTING FACILITIES IN THE DEMOLITION AND CONSTRUCTION DESCRIBED IN THE PLANS AND SPECIFICATIONS. 4.EXISTING CONDITIONS AS DEPICTED ON THESE PLANS ARE GENERAL AND ILLUSTRATIVE IN NATURE AND DO NOT INCLUDE MECHANICAL, ELECTRICAL AND MISCELLANEOUS STRUCTURES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EXAMINE THE SITE AND BE FAMILIAR WITH EXISTING CONDITIONS PRIOR TO BIDDING ON THE DEMOLITION WORK FOR THIS PROJECT. IF CONDITIONS ENCOUNTERED DURING EXAMINATION ARE SIGNIFICANTLY DIFFERENT THAN THOSE SHOWN, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY. 5.ALL DEMOLITION WASTE AND DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AND DISPOSED OF IN A STATE APPROVED WASTE SITE AND IN ACCORDANCE WITH ALL LOCAL AND STATE CODES AND PERMIT REQUIREMENTS. 6.THE BURNING OF CLEARED MATERIAL AND DEBRIS SHALL NOT BE ALLOWED UNLESS CONTRACTOR GETS WRITTEN AUTHORIZATION FROM THE LOCAL AUTHORITIES. 7.ASBESTOS OR HAZARDOUS MATERIALS, IF FOUND ON SITE, SHALL BE REMOVED BY A LICENSED HAZARDOUS MATERIALS CONTRACTOR. CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY IF HAZARDOUS MATERIALS ARE ENCOUNTERED. 8.CONTRACTOR SHALL PROTECT ALL CORNER PINS, MONUMENTS, PROPERTY CORNERS, AND BENCHMARKS DURING DEMOLITION ACTIVITIES. IF DISTURBED, CONTRACTOR SHALL HAVE DISTURBED ITEMS RESET BY A LICENSED SURVEYOR AT NO ADDITIONAL COST TO THE OWNER. 9.CONTRACTOR SHALL ADHERE TO ALL LOCAL, STATE, FEDERAL, AND OSHA REGULATIONS WHEN OPERATING DEMOLITION EQUIPMENT AROUND UTILITIES. 10.CONTRACTOR SHALL PROVIDE AND MAINTAIN TRAFFIC CONTROL MEASURES IN ACCORDANCE WITH THE NCDOT STANDARDS, AND AS REQUIRED BY LOCAL AGENCIES WHEN WORKING IN AND/OR ALONG STREETS, ROADS, HIGHWAYS, ETC. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN APPROVAL AND COORDINATE WITH THE LOCAL AND/OR STATE AGENCIES REGARDING THE NEED, EXTENT, AND LIMITATIONS ASSOCIATED WITH INSTALLING AND MAINTAINING TRAFFIC CONTROL MEASURES. 11.CONTRACTOR SHALL PROTECT AT ALL TIMES ADJACENT STRUCTURES AND ITEMS FROM DAMAGE DUE TO DEMOLITION OR CONSTRUCTION ACTIVITIES 12.CONTRACTOR SHALL REMOVE EXISTING VEGETATION AND IMPROVEMENTS WITHIN LIMITS OF DISTURBANCE UNLESS NOTED OTHERWISE. 13.TREES OUTSIDE OF CONSTRUCTION LIMITS OR TREES NOT INDICATED TO BE REMOVED SHALL BE PROTECTED. 14.IF SEPTIC TANK IS ENCOUNTERED/FOUND ON PREMISES DURING CONSTRUCTION ACTIVITIES, IT SHALL BE PROPERLY ABANDONED IN ACCORDANCE WITH ALL GOVERNING AGENCIES. 15.IF ANY WELL HEADS ARE ENCOUNTERED/FOUND ON PREMISES DURING CONSTRUCTION ACTIVITIES, IT SHALL BE PROPERLY ABANDONED IN ACCORDANCE WITH ALL GOVERNING AGENCIES, AND COMPLETED BY A CERTIFIED WELL DRILLER. 16.PROTECTIVE FENCING SHALL BE INSTALLED AROUND ANY PROTECTED TREES OR TREE STANDS PRIOR TO ANY CONSTRUCTION ACTIVITIES. ALL TREE PROTECTION FENCING SHALL BE A MINIMUM OF 4 FEET TALL AND ADHERE TO THE UNIFIED DEVELOPMENT ORDNANCE. Erosion Control Provisions 1.NO PERSON MAY INITIATE A LAND DISTURBING ACTIVITY BEFORE NOTIFYING THE NC DEPARTMENT OF WATER QUALITY OF THE DATE THAT THE LAND DISTURBING ACTIVITY WILL BEGIN. 2.SEED OR OTHERWISE PROVIDE GROUND COVER DEVICES OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION FOR ALL EXPOSED SLOPES WITHIN 7 DAYS OF COMPLETION OF ANY PHASE OF GRADING ON PERIMETER AREAS AND SLOPES STEEPER THAN 3:1. ALL OTHER AREAS SHALL BE STABILIZED WITHIN 14 DAYS. 3.CONTRACTOR SHALL INSPECT AND MAINTAIN AS NEEDED ALL EROSION CONTROL DEVICES ON A WEEKLY BASIS AND AFTER EACH MAJOR STORM EVENT. FAILURE TO KEEP ALL EROSION CONTROL DEVICES IN PROPER WORKING ORDER MAY RESULT IN A STOP WORK ORDER OR CIVIL PENALTIES UP TO $5,000.00 PER DAY OF VIOLATION. 4.THE CITY ENGINEER RESERVES THE RIGHT TO REQUIRE ADDITIONAL EROSION CONTROL MEASURES SHOULD THE PLAN OR ITS IMPLEMENTATION PROVE TO BE INADEQUATE. 5.EROSION CONTROL MEASURES SHALL BE MAINTAINED AND INSPECTED AS PER THE DETAIL SHEETS SHOWN. 6.PLEASE BE ADVISED OF THE RULES TO PROTECT AND MAINTAIN EXISTING BUFFERS ALONG WATERCOURSES IN THE NEUSE AND TAR/PAMLICO RIVER BASINS. THESE RULES ARE ENFORCED BY THE DIVISION OF WATER QUALITY (DWQ). DIRECT ANY QUESTIONS ABOUT THE APPLICABILITY OF THESE RULES TO YOUR PROJECT TO THE REGIONAL WATER QUALITY SUPERVISOR, WASHINGTON REGIONAL OFFICE AT (252) 946-6481. 7.ACCEPTANCE AND APPROVAL OF THIS PLAN IS CONDITIONED UPON YOUR COMPLIANCE WITH FEDERAL AND STATE WATER QUALITY LAWS, REGULATION AND RULES. IN ADDITION LOCAL CITY AND COUNTY ORDINANCES OR RULES MAY ALSO APPLY TO THIS LAND DISTURBING ACTIVITY. APPROVAL BY THE CITY DOES NOT SUPERSEDE ANY OTHER PERMIT OR APPROVAL. 8.LAND DISTURBING ACTIVITY BEYOND THAT REQUIRED TO INSTALL APPROPRIATE EROSION CONTROL MAY NOT PROCEED UNTIL EROSION CONTROL MEASURES ARE INSPECTED AND APPROVED BY THE CITY. 9.SCHEDULING OF A PRE-CONSTRUCTION CONFERENCE WITH THE EROSION CONTROL INSPECTOR IS REQUIRED PRIOR TO INITIATING LAND DISTURBING ACTIVITIES. FOR INSPECTION CALL (252) 329-4467. 24 HOUR NOTICE IS REQUIRED. 10.INSTALL ROCK INLET SEDIMENT TRAPS AROUND ALL CATCH BASINS, DROP INLETS, AND YARD INLETS. 11.PROVIDE 20' X 50' X 6" STONE CONSTRUCTION ENTRANCES AS SHOWN ON PLAN. LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD L O D L O D L O D L O D L O D L O D L O D L O D LOD LOD LOD LOD LOD LOD LOD LOD L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D LO D L O D L O D L O D LODLODLOD LO D L O D LO D L O D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LOD LOD LOD US H W Y 1 3 3 - C A S T L E H A Y N E R O A D N O R T H 2 3 r d S T R E E T SF S F S F S F S F SFSF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF S F S F S F S F S F S F S F PROTECT EX. UTILITIES (TYP) PROTECT EX. UTILITIES (TYP) PROTECT EX. UTILITIES (TYP) PROTECT EX. UTILITIES (TYP) PROTECT ADJOINING PROPERTY (TYP) CONCRETE WASHOUT TEMPORARY GRAVEL CONSTRUCTION ENTRANCE (20'Wx50'Lx6"THICK) TEMPORARY 24" RCP TDDTDD TDD TDD T D D TD D TD D TD D TD D TD D TD D TD D TD D TD D TD D TD D TD D T D D T D D T D D T D D T D D T D D T D D T D D SKIMMER SEDIMENT BASIN (SSB-1) BOTTOM EL. 21.0 15' WEIR EL. 23.0 TOP EL. 24.5 TEMP. DIVERSION DITCH (TDD-1) UPSTREAM INV.: 26.0 DOWNSTREAM INV.: 22.0 MIN. DEPTH: 2'-0" TEMP. DIVERSION DITCH (TDD-2) UPSTREAM INV.: 26.0 DOWNSTREAM INV.: 22.0 MIN. DEPTH: 2'-0" TREE PROTECTION AREA SF SF SF SF POWER POLE TO BE RELOCATED LEGEND EXISTING PROPOSED TA=X.XX TC=X.XX BC=X.XX WM GMGV CO GR I D 0 SCALE 1 inch = ft 30' 30 30'15' 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S KNOW WHAT'S BELOW CALL BEFORE YOU DIG! 1-800-632-4949 WWW.NC811.ORG R C2.1 PH A S E 2 E R O S I O N C O N T R O L P L A N Construction Sequence: CONTRACTOR MUST SCHEDULE A PRE-CONSTRUCITON MEETING WITH THE EROSION CONTROL INSPECTOR PRIOR TO INITIATING ANY LAND DISTURBING ACTIVITY. 1.INSTAL ALL PERIMETER CONTROL DEVICES, INCLUDING PIPE INLET PROTECTION ON THE DOWNSTREAM CULVERT, SILT FENCING, AND TEMPORARY CONSTRUCTION ENTRANCE. 2.CLEAR AND GRUB THE SITE. 3.STRIP AND STOCKPILE TOPSOIL. 4.STORM DRAINAGE INSTALLATION 5.ROUGH GRADING 6.BUILDING PAD(S) INSTALLATION 7.ROUGH GRADING COMPLETION 8.UTILITY INSTALLATION 9.INSTALLATION OF CONCRETE CURB AND GUTTER 10.PLACEMENT OF STONE BASE 11.BUILDING CONSTRUCTION 12.UNDERGROUND ELECTRIC INSTALLATION 13.FINE GRADING OF PARKING LOTS 14.PLACEMENT OF CONCRETE / ASPHALT PAVEMENT 15.INSTALL PAVEMENT MARKINGS / SIGNAGE 16.INSTALL LANDSCAPING AND COMENCE SEEDING AND MULCHING NOTE: 1.MAINTAIN EROSION CONTROL MEASURES UNTIL VEGETATION IS ESTABLISHED (>80% COVERAGE) 2.REMOVE ALL EROSION CONTROL MEASURES AND VEGETATE / STABILIZE LOCATION OF PREVIOUS EROSION CONTROL MEASURES SEVERAL ITEMS LISTED ABOVE MAY BE CONSTRUCTED SIMULTANEOUSLY. AN ANTICIPATED TIME SCHEDULE OF 10 MONTHS IS EXPECTED FOR THIS PROJECT. Demolition Notes: 1.CONTRACTOR SHALL CONTACT NORTH CAROLINA ONE-CALL CENTER (NC 811) BY DIALING 811 OR 1-800-632-4949 AT LEAST 72 HOURS IN ADVANCE OF ANY LAND DISTURBING ACTIVITY OR DIGGING AND HAVE ALL UNDERGROUND UTILITIES LOCATED PRIOR TO EXCAVATING OR TRENCHING. 2.THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL LOCAL AND STATE PERMITS REQUIRED FOR DEMOLITION WORK. 3.THE CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLESS THE OWNER AND/OR ENGINEER FOR ANY AND ALL INJURIES AND/OR DAMAGES TO PERSONNEL, EQUIPMENT AND/OR EXISTING FACILITIES IN THE DEMOLITION AND CONSTRUCTION DESCRIBED IN THE PLANS AND SPECIFICATIONS. 4.EXISTING CONDITIONS AS DEPICTED ON THESE PLANS ARE GENERAL AND ILLUSTRATIVE IN NATURE AND DO NOT INCLUDE MECHANICAL, ELECTRICAL AND MISCELLANEOUS STRUCTURES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EXAMINE THE SITE AND BE FAMILIAR WITH EXISTING CONDITIONS PRIOR TO BIDDING ON THE DEMOLITION WORK FOR THIS PROJECT. IF CONDITIONS ENCOUNTERED DURING EXAMINATION ARE SIGNIFICANTLY DIFFERENT THAN THOSE SHOWN, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY. 5.ALL DEMOLITION WASTE AND DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AND DISPOSED OF IN A STATE APPROVED WASTE SITE AND IN ACCORDANCE WITH ALL LOCAL AND STATE CODES AND PERMIT REQUIREMENTS. 6.THE BURNING OF CLEARED MATERIAL AND DEBRIS SHALL NOT BE ALLOWED UNLESS CONTRACTOR GETS WRITTEN AUTHORIZATION FROM THE LOCAL AUTHORITIES. 7.ASBESTOS OR HAZARDOUS MATERIALS, IF FOUND ON SITE, SHALL BE REMOVED BY A LICENSED HAZARDOUS MATERIALS CONTRACTOR. CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY IF HAZARDOUS MATERIALS ARE ENCOUNTERED. 8.CONTRACTOR SHALL PROTECT ALL CORNER PINS, MONUMENTS, PROPERTY CORNERS, AND BENCHMARKS DURING DEMOLITION ACTIVITIES. IF DISTURBED, CONTRACTOR SHALL HAVE DISTURBED ITEMS RESET BY A LICENSED SURVEYOR AT NO ADDITIONAL COST TO THE OWNER. 9.CONTRACTOR SHALL ADHERE TO ALL LOCAL, STATE, FEDERAL, AND OSHA REGULATIONS WHEN OPERATING DEMOLITION EQUIPMENT AROUND UTILITIES. 10.CONTRACTOR SHALL PROVIDE AND MAINTAIN TRAFFIC CONTROL MEASURES IN ACCORDANCE WITH THE NCDOT STANDARDS, AND AS REQUIRED BY LOCAL AGENCIES WHEN WORKING IN AND/OR ALONG STREETS, ROADS, HIGHWAYS, ETC. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN APPROVAL AND COORDINATE WITH THE LOCAL AND/OR STATE AGENCIES REGARDING THE NEED, EXTENT, AND LIMITATIONS ASSOCIATED WITH INSTALLING AND MAINTAINING TRAFFIC CONTROL MEASURES. 11.CONTRACTOR SHALL PROTECT AT ALL TIMES ADJACENT STRUCTURES AND ITEMS FROM DAMAGE DUE TO DEMOLITION OR CONSTRUCTION ACTIVITIES 12.CONTRACTOR SHALL REMOVE EXISTING VEGETATION AND IMPROVEMENTS WITHIN LIMITS OF DISTURBANCE UNLESS NOTED OTHERWISE. 13.TREES OUTSIDE OF CONSTRUCTION LIMITS OR TREES NOT INDICATED TO BE REMOVED SHALL BE PROTECTED. Erosion Control Provisions 1.NO PERSON MAY INITIATE A LAND DISTURBING ACTIVITY BEFORE NOTIFYING THE NC DEPARTMENT OF WATER QUALITY OF THE DATE THAT THE LAND DISTURBING ACTIVITY WILL BEGIN. 2.SEED OR OTHERWISE PROVIDE GROUND COVER DEVICES OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION FOR ALL EXPOSED SLOPES WITHIN 7 DAYS OF COMPLETION OF ANY PHASE OF GRADING ON PERIMETER AREAS AND SLOPES STEEPER THAN 3:1. ALL OTHER AREAS SHALL BE STABILIZED WITHIN 14 DAYS. 3.CONTRACTOR SHALL INSPECT AND MAINTAIN AS NEEDED ALL EROSION CONTROL DEVICES ON A WEEKLY BASIS AND AFTER EACH MAJOR STORM EVENT. FAILURE TO KEEP ALL EROSION CONTROL DEVICES IN PROPER WORKING ORDER MAY RESULT IN A STOP WORK ORDER OR CIVIL PENALTIES UP TO $5,000.00 PER DAY OF VIOLATION. 4.THE STATE AND THE ENGINEER RESERVE THE RIGHT TO REQUIRE ADDITIONAL EROSION CONTROL MEASURES SHOULD THE PLAN OR ITS IMPLEMENTATION PROVE TO BE INADEQUATE. 5.EROSION CONTROL MEASURES SHALL BE MAINTAINED AND INSPECTED AS PER THE DETAIL SHEETS SHOWN. 6.PLEASE BE ADVISED OF THE RULES TO PROTECT AND MAINTAIN EXISTING BUFFERS ALONG WATERCOURSES IN THE NEUSE AND TAR/PAMLICO RIVER BASINS. THESE RULES ARE ENFORCED BY THE DIVISION OF WATER QUALITY (DWQ). DIRECT ANY QUESTIONS ABOUT THE APPLICABILITY OF THESE RULES TO YOUR PROJECT TO THE REGIONAL WATER QUALITY SUPERVISOR, WASHINGTON REGIONAL OFFICE AT (252) 946-6481. 7.ACCEPTANCE AND APPROVAL OF THIS PLAN IS CONDITIONED UPON YOUR COMPLIANCE WITH FEDERAL AND STATE WATER QUALITY LAWS, REGULATION AND RULES. IN ADDITION LOCAL CITY AND COUNTY ORDINANCES OR RULES MAY ALSO APPLY TO THIS LAND DISTURBING ACTIVITY. APPROVAL BY THE CITY DOES NOT SUPERSEDE ANY OTHER PERMIT OR APPROVAL. 8.LAND DISTURBING ACTIVITY BEYOND THAT REQUIRED TO INSTALL APPROPRIATE EROSION CONTROL MAY NOT PROCEED UNTIL EROSION CONTROL MEASURES ARE INSPECTED AND APPROVED BY THE CITY. 9.SCHEDULING OF A PRE-CONSTRUCTION CONFERENCE WITH THE EROSION CONTROL INSPECTOR IS REQUIRED PRIOR TO INITIATING LAND DISTURBING ACTIVITIES. FOR INSPECTION CALL (252) 329-4467. 24 HOUR NOTICE IS REQUIRED. 10.INSTALL ROCK INLET SEDIMENT TRAPS AROUND ALL CATCH BASINS, DROP INLETS, AND YARD INLETS. 11.PROVIDE 20' X 50' X 6" STONE CONSTRUCTION ENTRANCES AS SHOWN ON PLAN. LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD L O D L O D L O D L O D L O D L O D L O D L O D LOD LOD LOD LOD LOD LOD LOD LOD L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D LO D L O D L O D L O D LODLODLOD LO D L O D LO D L O D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LOD LOD LOD US H W Y 1 3 3 - C A S T L E H A Y N E R O A D N O R T H 2 3 r d S T R E E T 25 25 21 21 22 22 23 23 24 24 26 26 27 28 28 28 28 29 29 2 6 2 7 2 8 2 9 30 27 27 2829 SF S F S F S F S F SFSF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF S F S F S F S F S F S F S F 28.02 TC/TA 29.19 TC/TA BC=27.33 BC=27.28 BC=28.00 BC=27.26 BC=27.87 BC=26.85 BC=28.34 TC/TA=27.72 BC=27.26 BC=27.31 BC=27.20 BC=27.37 BC=26.89 BC=27.74 TC/TA=28.10 27.97 TC/TA 28.00 TC/TA TC/TA=28.10 TC/TA=28.30 TC/TA=28.30 29.19 TC/TA BC=28.24 TC=29.41 TC=29.49TC=29.49 TC=29.42 TC=29.50 BC=27.91 BC=27.88 BC=27.46 BC=27.44 BC=29.03 TC/TA=29.19 TC=28.68 TC=28.65 TC=28.68 TC=28.62 BC=27.31 BC=27.48 BC=27.52 BC=27.55 BC=27.87 47.6' 58 . 2 ' 27.7' ROYAL FARMS TYPE LEANCON (LEFT) 4,710 S.F. 15" RCP @ 0.30% TC=28.57 TC=28.47 TC=28.52 TC=28.09 TC=29.31 0+00 1+00 2+ 0 0 2+ 4 6 . 3 1 15" RCP @ 0.30% 15" RCP @ 0.30% 18" RCP @ 0.30%18" RCP @ 1.00% 18" RCP @ 0.30% 18" RCP @ 0.30% JURISDICTIONAL STREAM BC=27.71 BC=27.53 BC=27.56 BC=27.53 BC=27.48 CB-102 RIM 27.85 INV. 24.12 (S) OUT 24.12 (N) CB-101 RIM 27.23 OUT 24.23 (N) CB-106 RIM 27.25 INV. 22.94 (NW) OUT 22.94 (S) CB-103 RIM 26.91 INV. 23.81 (S) OUT 23.81 (E) CB-105 RIM 27.12 INV. 23.16 (NW) OUT 23.16 (SE) CB-104 RIM 27.14 INV. 23.47 (W) OUT 23.47 (SE) FES-400 FES-200 FES-301 FES-300 FES-201 INV. 23.50 FES-100 TC=29.19 BC/TC=29.08 BC=28.82 BC=27.32 TC/TA=27.71 BC=27.11 FFE=29.60 TC=29.58TC=29.58 SF SF SF SF CLASS 3 RIP-RAP APRON ENTRY WIDTH: 9'-0" EXIT WIDTH: 9'-0" LENGTH: 7'-0" DEPTH: 22" 15" RCP @ 0.30% 23.00 22.50 22.50 23.00 24.10 24.10 23.40 23.40 24.00 23.50 23.5024.00 24.00 24.00 23.75 23.75 20.70 22.48 20.96 20.95 20.97 CLASS 4 RIP-RAP APRON ENTRY WIDTH: 3'-0" EXIT WIDTH: 6'-0" LENGTH: 9'-0" DEPTH: 25" SPILL WAY EXTEND 18" RCP 19'-8" MATCHING EXISTING PIPES SLOPE. (INV. OUT: 20.45) TC=28.62 TC/TA=28.47 15" RCP @ 0.30% 21.91 22.15 22.68 20.51 TC/TA=27.19 LEGEND OHE G S W X EXISTING PROPOSED UGE S TA=X.XX TC=X.XX BC=X.XX WM GMGV CO C RD TPF TPF GR I D 18 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 18 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 +-25 0+00 +25 +50 +75 1+00 +25 +50 +75 2+00 +25 +50 +75 3+00 +25 3+50 INV = 20.51 INV = 20.70 INV = 22.94 18" RCP @ 0.3% 15" RCP @ 0.3%PROPOSED GRADE EMERGENCY OVERFLOW ELEVATION: 23.50 25 YEAR STORM MAX WATER ELEVATION: 23.42 0 SCALE 1 inch = ft 30' 30 30'15' 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S C3.0 GR A D I N G P L A N KNOW WHAT'S BELOW CALL BEFORE YOU DIG! 1-800-632-4949 WWW.NC811.ORG R Grading Notes: 1.ALL AREAS WITHIN LIMITS OF DISTURBANCE SHALL BE CLEARED AND GRUBBED. 2.CONTRACTOR SHALL REMOVE EXISTING VEGETATION AND IMPROVEMENTS WITHIN LIMITS OF DISTURBANCE UNLESS NOTED OTHERWISE. 3.TREES OUTSIDE OF CONSTRUCTION LIMITS OR TREES NOT INDICATED TO BE REMOVED SHALL BE PROTECTED. 4.THE BURNING OF CLEARED MATERIAL AND DEBRIS SHALL NOT BE ALLOWED UNLESS CONTRACTOR GETS WRITTEN AUTHORIZATION FROM THE LOCAL AUTHORITIES. 5.ALL DEMOLITION WASTE AND DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AND DISPOSED OF IN A STATE APPROVED WASTE SITE AND IN ACCORDANCE WITH ALL LOCAL AND STATE CODES AND PERMIT REQUIREMENTS. 6.CONTRACTOR TO GRADE ALL AREAS WITHIN THE LIMITS OF DISTURBANCE FROM BUILDING TO PROPERTY LINES AND TO EDGE OF PAVEMENT ON STREET SIDES, INCLUDING ROW. 7.TOP SOIL SHALL BE STRIPPED FROM ALL CUT AND FILL AREAS, STOCKPILED AND REDISTRIBUTED OVER GRADED AREAS. PROVIDE EROSION AND SEDIMENTATION CONTROLS AROUND STOCKPILES DURING CONSTRUCTION. 8.TILL SOIL TO A DEPTH OF 4" MINIMUM. 9.REMOVE ALL ROCKS LARGER THAN 1" MEASURED IN LARGEST DIRECTION. 10.GRADE ALL AREAS TO MAINTAIN POSITIVE SLOPE AWAY FROM BUILDING. 11.ALL GRADED AREAS TO RECEIVE SEED OR SOD, TOP SOIL, STRAW AND WATER UNTIL A HEALTHY STAND OF GRASS IS OBTAINED. 12.INSTALL TEMPORARY TURF REINFORCEMENT MATTING ON ALL SLOPES STEEPER THAN 3:1. MATTING SHALL BE CONTECH LANDLOK C2 OR EQUAL. 13.REFER TO SHEET C-8 FOR DETAILS OF PAVEMENT IN PARKING AND DRIVE AREAS. 14.DUMPSTER PAD AND APRON SHALL BE 6" THICK 4,000 PSI CONCRETE OVER NOT LESS THAN 4" OF COMPACTED AGGREGATE BASE COURSE. REINFORCING SHALL BE #4 REBAR @ 12" ON CENTER IN EACH DIRECTION. REBAR SHALL BE LOCATED IN UPPER 1/3 OF SLAB AND SUPPORTED ON CHAIRS. 15.ALL SIDEWALKS SHALL BE CONSTRUCTED OF 4" THICK 3,500 PSI CONCRETE REINFORCED WITH 6x6 W1.4xW1.4 WELDED WIRE FABRIC. ALL SIDEWALKS SHALL HAVE TOOLED CONTROL JOINTS NOT EXCEEDING 5' SPACING IN ANY DIRECTION. 16.ALL BUILDING, SIDEWALK, AND PAVEMENT SUB-GRADES SHALL BE COMPACTED TO 100% OF ASTM D698 TO A DEPTH OF 24" AND TO 95% OF ASTM D698 BELOW 24" DEPTHS. ALL OTHER NON-STRUCTURAL AREAS SHALL BE COMPACTED TO 90% OF ASTM D698. 17.ALL BUILDING, SIDEWALK, AND PAVEMENT SUB-GRADE COMPACTIONS SHALL BE INTERMEDIATELY TESTED AND APPROVED BY THE GEOTECHNICAL ENGINEER. ALL SUB-GRADES SHALL BE THOROUGHLY PROOF-ROLLED TO IDENTIFY SMALL LOCALIZED AREAS OF UNSUITABLE SOILS. ALL UNSUITABLE SOILS SHALL BE UNDERCUT, REPLACED WITH STRUCTURAL FILL, AND COMPACTED AS DESCRIBED ABOVE. 18.CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH UTILITY PROVIDERS FOR THE RELOCATION / ABANDONMENT OF EXISTING UTILITIES AND INSTALLATION OF NEW UTILITY SERVICES AS WELL AS FEES ASSOCIATED WITH SUCH WORK. 19.COORDINATE WITH MEP PLANS FOR ELECTRICAL SERVICE INFORMATION. 0 SCALE 1 inch = ft 30' 30 30'15' VERT.1 inch = ft3 DRY DETENTION BASIN CROSS-SECTION SCALE: 1"=30'VERT.: 1"=3' G G G G G G G G G G G SS S S S S SS S S S SCOCO G G C C C C C C C C W W W W W W W W GV CO SSS S S S CO E GM WM S S S CO CO UG E UG E UG E UG E UG E UG E UGEUGEUGE UGE UGE STORMWATER MANAGEMENT AREA 47.6' 58 . 2 ' 27.7' ROYAL FARMS TYPE LEANCON (LEFT) 4,710 S.F. GREASE HOLDING TANK 2" PVC DOMESTIC WATER SERVICE GAS METER PROPOSED GAS LINE FROM GAS METER FOR CONNECTION AT STORE APPROXIMATE LOCATION OF PRIMARY UNDERGROUND ELECTRIC SERVICE. EXACT LOCATION TO BE COORDINATED WITH UTILITY PROVIDER. SECONDARY ELECTRIC RUN FROM PAD MOUNTED TRANSFORMER TO MEP ROOM. UNDERGROUND TELEPHONE LINE TO BE ROUTED TO MEP ROOM. APPROXIMATE LOCATION OF PAD MOUNTED TRANSFORMER. EXACT LOCATION TO BE COORDINATED WITH UTILITY PROVIDER. 2" WATER METER (DOMESTIC) WITH 2" GATE VALVE AND 1" WATER METER (IRRIGATION) TO BE INSTALLATED BY LICENSED UTILITY CONTRACTOR CLEAN OUT INV. TO BE INSTALLED MIN. 3'-9" BELOW FINISHED FLOOR ELEVATION. PROPOSED 1500 GALLON GREASE INTERCEPTOR 6" SANITARY SEWER @ 2.0% MIN. COMMERCIAL DUPLEX GRINDER PUMP STATION FORCE MAIN PARALLEL TO N 23RD STREET TO BE CONSTRUCTED BY OTHERS. REFER TO "PRIVATE FORCE MAIN EXTENSION" PLANS FOR CASTLE HAYNE INVESTMENTS PREPARED BY HANOVER DESIGN SERVICES, P.A. TAPPING SLEEVES AND VALVES TO BE INSTALLED BY LICENSED UTILITY CONTRACTOR WM GATE VALVE AT RIGHT OF WAY LINE IS CFPUA POINT OF SERVICE CO CO CO CO CO CO CO RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RDRDRDRD RDRDRDRDRD RD RD RD RD 2" RPZ IN ABOVE GROUND HEATED ENCLOSURE (BY CONTRACTOR) 1" IRRIGATION RPZ IN ABOVE GROUND HEATED ENCLOSURE (BY CONTRACTOR) 0+ 0 0 1+ 0 0 2 + 0 0 3 + 0 0 3 + 1 6 . 3 3 1" PVC IRRIGATION WATER SERVICE REMOVE PLUG AND TIE INTO EXISTING 2" STUB AT GATE VALVE. INSTALLED DURING 4" C900 PVC FORCE MAIN INSTALLATION PROJECT. COORDINATE TEMPORARY SHUTOFF OF NEARBY SERVICE AS REQUIRED WITH CFPUA. TAPPING SLEEVES AND VALVE FOR RELOCATED FIRE HYDRANT ASSEMBLY RELOCATED FIRE HYDRANT ASSEMBLY 2" HDPE FORCE MAIN CONNECTION. TO BE JACK AND BORED. S S S S S FM FM FM FM FM CONTRACTOR TO VERIFY UNDERGROUND UTILITY LOCATIONS AND DEPTHS PRIOR TO INSTALLING FORCE MAIN LEGEND EXISTING PROPOSED TA=X.XX TC=X.XX BC=X.XX WM GMGV CO GR I D 15 20 25 30 15 20 25 30 -0+25 0+00 1+00 2+00 3+00 3+50 COMMERCIAL DUPLEX GRINDER PUMP STATION GREASE TRAP 6" GRAVITY SEWER APPROXIMATE TIE-IN LOCATION/ELEVATION: 15.6± EXCAVATED RECEIVING PIT (JACK & BORE)EXCAVATED AREA (JACK & BORE) 70 LF 8" STEEL ENCASEMENT (JACK & BORE) 6" PVC - 55.47 LF @ 1 . 2 2 % 6" PVC - 3.12 LF @ 1.50% S-39 RIM 29.01 INV. 24.20 (W) OUT 24.20 (E) 6" PVC - 1.23 LF @ 1.50% 6" PVC - 30.09 L F @ 1 . 5 0 % S-38 RIM 29.53 INV. 24.65 (S) OUT 24.65 (E) 6" PVC - 58.85 L F @ 1 . 5 0 % S-37 RIM 28.60 INV. 25.54 (W) OUT 25.54 (N) 6" PVC - 20.69 LF @ 1.50% S-36 RIM 29.17 INV. 25.85 (N) OUT 25.85 (E) 6" P V C 6" PVC 2" HDPE @ 2.96% 2" HDPE @ 33.78% 2" VALVE 2" VALVE 0 SCALE 1 inch = ft 20' 20 20'10' 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S KNOW WHAT'S BELOW CALL BEFORE YOU DIG! 1-800-632-4949 WWW.NC811.ORG R C4.0 UT I L I T Y P L A N Utility Providers: STORM DRAINAGE: New Hanover County Contact:Jerry May Phone:(910) 798-7129 ELECTRIC UTILITIES: Duke Energy Contact:Distribution Construction Service Phone:(800) 452-2777 WATER & SANITARY SEWER: Cape Fear Public Utility Authority Contact:Engineering/Inspections Phone:(910) 322-6550 NCDOT: Division of Highway Contact:D. Chad Kimes, PE Phone:(910) 341-2001 CABLE TV: Spectrum Contact:General Phone:(800) 892-4357 GAS: Piedmont Natural Gas Contact:Cathy Pleasant Phone:(910) 251-2827 PUBLIC STREETS: New Hanover County Contact:Staff Phone:(910) 798-7053 TELEPHONE: AT&T/Bell South Contact:Steve Dayvault Phone:(910) 341-0741 Utility Separation Requirements A.SEWERS SHALL BE LAID AT LEAST 10 FEET HORIZONTALLY FROM ANY EXISTING OR PROPOSED WATER MAIN. THE DISTANCE SHALL BE MEASURED EDGE TO EDGE. IN CASES WHERE IT IS NOT PRACTICAL TO MAINTAIN A 10 FOOT SEPARATION, THE APPROPRIATE REVIEWING AGENCY MAY ALLOW DEVIATION ON A CASE BY CASE BASIS, IF SUPPORTED BY DATA FROM THE DESIGN ENGINEER. SUCH DEVIATION MAY ALLOW INSTALLATION OF THE SEWER CLOSER TO A WATER MAIN, PROVIDED THAT THE WATER MAIN IS IN A SEPARATE TRENCH OR ON AN UNDISTURBED EARTH SHELF LOCATED ON ONE SIDE OF THE SEWER AND AT AN ELEVATION SO THE BOTTOM OF THE WATER MAIN IS AT LEAST 24 INCHES ABOVE THE TOP OF THE SEWER. B.IF IT IS IMPOSSIBLE TO OBTAIN PROPER HORIZONTAL AND VERTICAL SEPARATION AS DESCRIBED ABOVE OR ANYTIME THE SEWER IS OVER THE WATER MAIN, BOTH WATER MAIN AND SEWER MUST BE CONSTRUCTED OF FERROUS PIPE COMPLYING WITH PUBLIC WATER SUPPLY DESIGN STANDARDS AND BE PRESSURE TESTED TO 150 PSI TO ASSURE WATERTIGHTNESS BEFORE BACKFILLING. C.A 24 INCH VERTICAL SEPARATION SHALL BE PROVIDED BETWEEN STORM SEWER AND SANITARY SEWER LINES OR FERROUS PIPE SPECIFIED. CROSSINGS: A.SEWERS CROSSING WATER MAINS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 24 INCHES BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF THE SEWER. THE CROSSING SHALL BE ARRANGED SO THAT THE SEWER JOINTS WILL BE EQUIDISTANT AND AS FAR AS POSSIBLE FROM THE WATER MAIN JOINTS. B.WHEN IT IS IMPOSSIBLE TO OBTAIN PROPER HORIZONTAL AND VERTICAL SEPARATION AS STIPULATED ABOVE, ONE OF THE FOLLOWING METHODS MUST BE SPECIFIED: I. THE SEWER SHALL BE DESIGNED AND CONSTRUCTED OF FERROUS PIPE AND SHALL BE PRESSURE TESTED AT 150 PSI TO ASSURE WATERTIGHTNESS PRIOR TO BACKFILLING, OR II. EITHER THE WATER MAIN OR THE SEWER LINE MAYBE ENCASED IN A WATERTIGHT CARRIER PIPE WHICH EXTENDS 10 FEET ON BOTH SIDES OF THE CROSSING, MEASURED PERPENDICULAR TO THE WATER MAIN. THE CARRIER PIPE SHALL BE OF MATERIALS APPROVED BY THE REGULATORY AGENCY OF USE IN WATER MAIN CONSTRUCTION. Utility Notes: 1.CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH UTILITY PROVIDERS FOR THE RELOCATION / ABANDONMENT OF EXISTING UTILITIES AND INSTALLATION OF NEW UTILITY SERVICES AS WELL AS FEES ASSOCIATED WITH SUCH WORK. 2.COORDINATE WITH MEP PLANS FOR ELECTRICAL SERVICE INFORMATION. 3.ADJUSTMENT OF MH TOPS TO BE ACCORDANCE WITH GUC MANUAL. (NO MORE THAN 2 GRADE RINGS) 4.ANY CLEANOUT THAT FALLS IN PAVEMENT WILL NEED TO BE PER DETAIL S-3 GUC MANUAL. 5.TEMPORARY BACTERIOLOGICAL SAMPLE POINTS (BSP) SHALL BE CONSTRUCTED OF THE SAME MATERIALS AS ONE INCH WATER SERVICES. SAMPLE POINTS SHALL BE INSTALLED SUCH THAT THE ANGLE BALL VALVE IS SECURELY LOCATED 36" MIN. ABOVE FINISH GRADE. UPON APPROVAL OF FINAL BACTERIOLOGICAL SAMPLES, THE SERVICE TUBING AND BALL VALVE SHALL BE REMOVED, THE CORPORATION STOP CLOSED AND A CAP PLACED ON THE CORPORATION STOP. DIAGONAL BARS TO BE INNERMOST LAYER OF REINFORCEMENT EXTRA BARS EQUIVALENT TO AREA OF INTERRUPTED BARS. PLACE 1/2 THE NUMBER OF BARS ON EACH SIDE OF OPENING, ALL AROUND & ON EA. FACE VARIES VARIES 2" CL. (TYP.) (2) #6 BARS EA. FACE (TYP.) (2) #6 BARS EA. FACE (TYP.) "B" LAP LENGTH (TYP.) 2" C L . ( T Y P . ) "B" LAP LENGTH (TYP.) 2" C L . ( T Y P . ) "B" LAP LENGTH (TYP.) CIRCULAR RECTANGULAR EXPANSION JOINTS ARE REQUIRED TO ISOLATE STRUCTURES FROM CONCRETE. EXPANSION MATERIALS SHALL BE USED CONSISTING OF 1/2" PREMOLDED COMPRESSIVE FILLER COMPLYING WITH ASTM D1752, TYPE 1 TYPICAL OPENING REINFORCING DETAILS FOR CONCRETE AREAS W/VEHICLE ACCESS NOT TO SCALE 1/2" ISOLATION JOINT HELD 1/2" BELOW FINISH SIDEWALK WITH SEALANT 4" COMPACTED GRAVEL BASE COMPACTED SUBGRADE TO 98% MAX DRY DENSITY PER ASTM D1557 FINISH FLOOR 2% CROSS SLOPE (MAX)SEE NOTE USE ZIP STRIPS- FILL WITH POURABLE CAULK WIDTH= 1/4" BUILDING EXTERIOR WALL 4" NOTE: 1.ALL CONCRETE CURBS AND SIDEWALKS TO BE 4,000 P.S.I. CONCRETE. SIDEWALK PAVEMENT DETAIL NOT TO SCALE SIDEWALKS ADJACENT TO THE STORE ARE TO BE COLORED CONCRETE BROOM FINISHED PERPENDICULAR TO STORE FOR CONTROL/ EXPANSION JOINTS, PLEASE REFER TO EXHIBIT E.4 - COORDINATE W/ RF & CIVIL ENGINEER. COLORED CONCRETE: MANUFACTURER: INCRETE COLOR-CRETE COLOR: COAL MEDIUM FT9120 SEALANT: KAUFMAN KRYSTAL 25 OTC CONCRETE & FIBER REINFORCEMENT: F'C= 4,000 PSI NORMAL WEIGHT AIR-ENTRAINED, MAX W/C = 0.45; FIBER 1.5 LBS/ CUBIC YARD EUCLID TYPE F FIBRILLATED MICRO FIBER PSI FIBERSTRAND TO BE ADDED AT CONCRETE PLANT WORKABILITY: ADD HIGH RANGE WATER REDUCER (SUPERPLASTICIZER) AS NECESSARY TO ACHIEVE PROPER WORKABLE CONCRETE (APPROX. SLUMP = 6") BITMUNOUS CONCRETE PAVEMENT OR CONCRETE PER SITE PLAN POUR FLUSH W/ PROP. PAVEMENT GRADE TACK COAT 0.2 GAL./SQ. YARD CR-6 STONE SUBBASE SECTION VIEW CONCRETE & FIBER REINFORCEMENT: F'C= 4,000 PSI NORMAL WEIGHT AIR-ENTRAINED, MAX W/C = 0.45; FIBER 1.5 LBS/ CUBIC YARD EUCLID TYPE F FIBRILLATED MICRO FIBER PSI FIBERSTRAND TO BE ADDED AT CONCRETE PLANT WORKABILITY: ADD HIGH RANGE WATER REDUCER (SUPERPLASTICIZER) AS NECESSARY TO ACHIEVE PROPER WORKABLE CONCRETE (APPROX. SLUMP = 6") SEE PLAN FOR SIZE 6" 8" 6" CONCRETE PARKING PAD PAVEMENT DETAIL NOT TO SCALE COMPACTED PREPARED SUBGRADE - MIN 98% COMPACTION COLORED CONCRETE: MANUFACTURER: INCRETE COLOR-CRETE COLOR: COAL MEDIUM FT9120 SEALANT: KAUFMAN KRYSTAL 25 OTC FOR CONTROL/ EXPANSION JOINTS, PLEASE REFER TO EXHIBIT E.4 BITMUNOUS CONCRETE PAVEMENT OR CONCRETE PER SITE PLAN 28 DAY 4,000 PSI CLASS "A" CONCRETE TACK COAT 0.2 GAL./SQ. YARD COMPACTED PREPARED SUBGRADE #8 STONE SUBBASE SECTION VIEW CONCRETE & FIBER REINFORCEMENT : F'C= 4,000 PSI NORMAL WEIGHT AIR-ENTRAINED, MAX W/C = 0.45; FIBER 1.5 LBS/ CUBIC YARD EUCLID TYPE F FIBRILLATED MICRO FIBER PSI FIBERSTRAND TO BE ADDED AT CONCRETE PLANT WORKABILITY : ADD HIGH RANGE WATER REDUCER (SUPERPLASTICIZER) AS NECESSARY TO ACHIEVE PROPER WORKABLE CONCRETE (APPROX. SLUMP = 6") SEE PLAN FOR SIZE 8" 8" 8" CONCRETE FUEL TANK PAD DETAIL/ FUEL TANK LANDING PAD/ DIESEL FUEL CANOPY PAD/ DUMPSTER APRON PAD NOT TO SCALE 8" COMPACTED STONE BASE (COMPACTED TO 98% COMPACTED PER GEOTECHNICAL REPORT) COMPACTED SUBGRADE (PER GEOTECHNICAL REPORT) 2" ASPHALT SURFACE COURSE (COMPACTED TO 92-96% DENSITY) 3" ASPHALT BINDER COURSE (COMPACTED TO 92-96% DENSITY) NOTE: 1.REVISE TO MEET JOB AND LOCAL JURISDICTION REQUIREMENTS AND GEOTECHNICAL REPORT REQUIREMENTS. THE MINIMUM REQUIRED THICKNESS ARE SHOWN IN THE DETAIL. USE LOCAL DOT PAVEMENT MIX DESIGN FOR WEARING AND BINDING COURSES. 2.PROOF ROLL PREPARED SUBBASE SURFACE TO CHECK FOR UNSTABLE AREAS AND AREAS REQUIRING ADDITIONAL COMPACTION. NOTIFY ENGINEER OF UNSATISFACTORY CONDITIONS. DO NOT BEGIN PAVING WORK UNTIL DEFICIENT SUBBASE AREAS HAVE BEEN CORRECTED AND ARE READY TO RECEIVE PAVING. 3.VERIFY WITH GEOTECHNICAL ENGINEER FOR PAVEMENT THICKNESS. STANDARD ASPHALT PAVEMENT DETAIL NOT TO SCALE 1:12 MAX. SLOPE (TYP.) BUILDING WALL DEPRESSED CURB SIDEWALK AREA DE P R E S S E D WI D T H P E R SIT E P L A N C-1 0 1 EXTEND BUILDING WALL FINISH TO THIS AREA. NOTES: 1.ALL CONCRETE CURBS AND SIDEWALKS TO BE 4,000 P.S.I. CONCRETE. 2. PROVIDE EXPANSION JOINT MATERIAL WHERE CURB RAMP ADJOINS ANY RIGID PAVEMENT, SIDEWALK OR STRUCTURE WITH THE TOP OF JOINT FILLER PLUS SEALANT FLUSH WITH ADJACENT CONCRETE SURFACE. 3. SEAL JOINTS WITH AN APPROVED SEALING MATERIAL. 4. PROVIDE SLIP RESISTANT TEXTURE ON CURB RAMP BY COARSE BROOMING TRANSVERSE TO THE SLOPE OF THE RAMP. EXTEND TEXTURE THE FULL WIDTH AND LENGTH OF THE CURB RAMP INCLUDING FLARED SIDE RAMPS. 5. CURB RAMP AND SIDE FLARE LENGTHS ARE VARIABLE AND BASED ON CURB HEIGHT AND THE SIDEWALK PITCH. SEE TABLE A FOR TYPICAL RAMP DIMENSIONS. 6. WHENEVER POSSIBLE, CONSTRUCT THE TRANSITION SLOPE FROM THE CURB RAMP AND FLARE SIDES TO ADJOINING SURFACES WITH A GRADUAL CURVE RATHER THAN AN ABRUPT ANGLE. 7. DETECTABLE WARNING SURFACE COLOR TO BE : "BRICK RED" DEPRESSED CURB 7.5% MAX.SLOPE TOP OF CURB ROADWAY SURFACE DEPRESSED CURB 4" COMPACTED GRAVEL BASE ROADWAY SURFACE DETECTABLE WARNING SURFACE PREMOLDED EXP. JOINT FILLER (TYP.) 4" CONC. SIDEWALK LANDING MIN. 3'-0" FOR SIDEWALK WIDTHS LESS THAN 8'-0". MIN. 4'-0" FOR SIDEWALK WIDTHS MIN. 8'-0" OR WIDER PER CURRENT ADA STANDARDS. CURB RAMP SECTION CURB RAMP ELEVATION CROS S - S E C T I O N WIDTH S A M E A S SIDEW A L K 5'-0" M I N . BUILDING WALL PERIMETER CURB RAMP DETAIL NOT TO SCALE 18" 6"1" 6" 1" PAVEMENT DIMENSION(S) ON PLAN VIEW REFER TO FACE OF CURB 1. CONCRETE FOR CURBING SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4,000 P.S.I. @ 28 DAYS. 2. CONSTRUCTION STAKING FOR CURB INSTALLATION SHALL BE REFERENCED (CUT OR FILL) TO THE TOP OF CURB. 3. AT CONTRACTOR'S OPTION, THE GUTTER THICKNESS MAY BE INCREASED AT THE EDGE OF PAVEMENT TO MAKE BOTTOM OF GUTTER CONTIGUOUS WITH BOTTOM OF ASPHALT PAVEMENT. 4. CONTRACTION JOINTS SHALL BE PLACED @ 10'-0" O.C. TOOLED 1/4" (±1/16") WIDE, 1" DEEP. EXPANSION JOINTS SHALL BE PLACED @ 40'-0" INTERVALS, MAXIMUM, AND ALL P.C.'S. 18" 6" 1" 1" 1" SPILL CURB & GUTTER COLLECTOR CURB & GUTTER 6" PAVEMENT DIMENSION(S) ON PLAN VIEW REFER TO FACE OF CURB 5" NOTES: 1-1/2"R 1-1/2"R CONCRETE CURB & GUTTER DETAIL NOT TO SCALE NOT TO SCALE MOUNTABLE CURB DETAIL BITMUNOUS CONCRETE PAVEMENT OR CONCRETE PER SITE PLAN 28 DAY 4,000 PSI CLASS "A" CONCRETE POUR FLUSH W/ PROP. PAVEMENT GRADE TACK COAT 0.2 GAL./SQ. YARD #8 STONE SUBBASE SECTION VIEW SEE PLAN FOR SIZE 6" 8" 6" CONCRETE FUEL CANOPY PAD PAVEMENT DETAIL NOT TO SCALE COMPACTED PREPARED SUBGRADE - MIN 98% COMPACTION COLORED CONCRETE: MANUFACTURER: INCRETE COLOR-CRETE COLOR: COAL MEDIUM FT9120 SEALANT: KAUFMAN KRYSTAL 25 OTC ABOVE NOTE APPLIES TO DIESEL FUEL PAD & DIESEL TANK PAD. NOTE: CR-6 STONE SUBBASE FOR DUMPSTER APRON PAD ONLY, ALL OTHERS TO BE #8 STONE. CONCRETE & FIBER REINFORCEMENT: F'C= 4,000 PSI NORMAL WEIGHT AIR-ENTRAINED, MAX W/C = 0.45; FIBER 1.5 LBS/ CUBIC YARD EUCLID TYPE F FIBRILLATED MICRO FIBER PSI FIBERSTRAND TO BE ADDED AT CONCRETE PLANT WORKABILITY: ADD HIGH RANGE WATER REDUCER (SUPERPLASTICIZER) AS NECESSARY TO ACHIEVE PROPER WORKABLE CONCRETE (APPROX. SLUMP = 6") 6" M I N 9" BA C K O F C U R B 6"2' 14" R . 3" 1'-11 4"1034" 6" 1. A REVERSE GUTTER PAN SHALL HAVE A GUTTER SLOPE OF 4.17% AWAY FROM THE FLOW LINE, AND SHALL NOT BE USED WHERE THIS DRAINAGE CREATES A HAZARDOUS CONDITION 2. GUTTER PAN AT THE MEDIAN EDGE OF INTERMEDIATE ARTERIALS OR THE HIGH SIDE OF SUPER ELEVATED SECTIONS SHALL BE SLOPED AT THE SAME RATE AND IN THE SAME DIRECTION AS THE PAVEMENT. MATCH PAVEMENT CROSS SLOPE WHEN CURB IS LOCATED ON THE LOW SIDE OF SUPER ELEVATED SECTION AND THE RATE OF SUPER ELEVATION IS GREATER THAN 3% FOR MODIFIED CURB AND GUTTER. 3. A MINIMUM OF TWO (2) FEET OF COMPACTED STABILIZED EARTH. OR EQUIVALENT, SHALL SUPPORT THE ENTIRE BACK OF CURB. 4. A POSITIVE DRAINAGE SHALL BE PROVIDED BOTH BEHIND THE CURB AND ALONG THE GUTTER AND FLOW LINE. NOTE: MODIFIED COMBINATION CURB AND GUTTER POUR FLUSH W/ PROP. PAVEMENT GRADE 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S C5.0 DE T A I L S NOTES: 1. STEEL FOR POSTS SHALL CONFORM TO THE MECHANICAL REQUIREMENTS OF ASTM A 499-81 GRADE 60 AND TO THE CHEMICAL REQUIREMENTS OF ASTM AI-76 CARBON STEEL TEE RAIL HAVING NOMINAL WEIGHT OF 3 LB. OR GREATER PER LINEAR FOOT. 2. AFTER FABRICATION ALL STEEL POSTS SHALL BE GALVANIZED TO MEET THE REQUIREMENTS OF ASTM A-123. 3. SIGN MOUNTING HEIGHT TO BE PER MUTCD REQUIREMENTS. 4. ALL SIGN POSTS SHALL HAVE "BREAK AWAY" FEATURES THAT MEET AASHTO REQUIREMENTS CONTAINED IN "STANDARD SPECIFICATIONS FOR STRUCTURAL SUPPORTS FOR HIGHWAY SIGNS, LUMINAIRES AND TRAFFIC SIGNALS". THE "BREAK AWAY" FEATURES SHALL BE STRUCTURALLY ADEQUATE TO CARRY THE SIGN SHOWN ON THE PLANS AT 60 MPH WIND LOADINGS. INSTALLATIONS SHALL BE IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. HOLE LOCATION DETAIL B TAPER OPTIONAL 3/ 8 " D I A . H O L E S 1 " O . C . LE N G T H A S R E Q ' D F O R S I G N S I Z E HO L E S 1 " O . C . 3/ 8 " D I A . LE N G T H A S R E Q ' D F O R S I G N S I Z E TAPER OPTIONAL DETAIL A HOLE LOCATION 3" 1"GALVANIZED STEEL GALVANIZED STEEL 1" 1" TYPICAL METAL SIGN C B A WT.A B C 3 LB. OR 3 LB. 4 LB. 1-5/8" 1-5/16" 1-5/8" 1-3/4" 1-7/8" 1-3/4" 3-1/2" 3-1/2" 3-1/2" TYPICAL METAL SIGN POST DETAIL NOT TO SCALE SEE PLAN VIEW 1' - 6 " 4' TY P . WHITE REFLECTIVE TRAFFIC PAINT STOP BAR STOP SIGN STOP BAR GRAPHIC NOT TO SCALE 3" NON SHRINK GROUT, 1" SIKAFLEX - 2C POLYURETHANE SEALANT - REDWOOD (OR EQUIVALENT) PEA GRAVEL 6" SCH.40 STEEL PIPE 10" SCHEDULE 40 PVC SLEEVE 1" BELOW FINISHED SIDEWALK ELEVATION 1" SIKAFLEX - 2C POLYURETHANE SEALANT - REDWOOD 3" NON SHRINK GROUT 3000 PSI CONCRETE PVC SLEEVE CUT 1" BELOW FINISHED SIDEWALK ELEVATION PRESCORE NEOPRENE TAPE 1/8" PLASTIC SLEEVE BY IDEAL SHIELD (OR EQUIVALENT) 1/2" BELOW FINISH INTO SEALANT PEA GRAVEL CAP/PLATE WELDED TO END OF BOLLARD SUBGRADE DRILL 1/8"Ø HOLE IN BOLLARD SLEEVE 6" ABOVE GRADE CURB AT PARKING LOT ISLANDS AND ADJACENT TO SIDEWALKS OR 4" WHITE PAINT LINE IN NON CURBED DOUBLE PARKING BAYS. NOTES: 1.PROVIDE 2 COATS OF PAINT ON ALL SITE STRIPING. 2.SEE SITE PLAN FOR ACTUAL SPACE LOCATION AND DIMENSIONS. 3.CONCRETE JOINT TO LAND ON STRIPING. 4" WHITE PAINT LINE (TYP.)20 ' - 0 " ( T Y P . ) 4'-6" TYPICAL 9' PARKING SPACE DETAIL NOT TO SCALE 2'-3"2'-3" TYPICAL BOLLARD LAYOUT - SEE EXHIBIT "G" STANDARD DETAILS 4 FOR ADDITIONAL INFORMATION 5'-0"12'-0"12'-0" PROP. CONCRETE CURB PROP. DUAL VACUUM (CONTACT CAR WASH VENDOR) 20 ' - 0 " DUAL VACUUM PARKING PENINSULA LAYOUT WITH CAR WASH DETAIL NOT TO SCALE 12'-0" CAR WASH SITES ONLY TRASH CAN â„„ REMOTE E-STOP ON REMOVABLE BOLLARD DETAIL NOT TO SCALE REMOVABLE BOLLARD (TYP.) PROP. DUAL VACUUM (CONTACT CAR WASH VENDOR) TRASH CAN REMOVABLE BOLLARD (TYP.) 12'-0"5'-0" CURB AT PARKING LOT ISLANDS AND ADJACENT TO SIDEWALKS OR 4" WHITE PAINT LINE IN NON CURBED DOUBLE PARKING BAYS. NOTES: 1.PROVIDE 2 COATS OF PAINT ON ALL SITE STRIPING. 2.SEE SITE PLAN FOR ACTUAL SPACE LOCATION AND DIMENSIONS. 3.CONCRETE JOINT TO LAND ON STRIPING. 4" WHITE PAINT LINE (TYP.)20 ' - 0 " ( T Y P . ) 5'-0" TYPICAL 10' PARKING SPACE DETAIL NOT TO SCALE 2'-6"2'-6" TYPICAL BOLLARD LAYOUT - SEE EXHIBIT "G" STANDARD DETAILS 4 FOR ADDITIONAL INFORMATION REMOTE E-STOP ON REMOVABLE BOLLARD PLAN NOT TO SCALE 3500 P.S.I. CONCRETE SAND CUSHION 4" SEWER CLEANOUT CAP 6" PVC ENCASEMENT PIPE ASPHALT OR CONCRETE AS DETERMINED BY TRAFFIC SURFACE 4,000 P.S.I CONCRETE TRAFFIC RATED CLEANOUT COVER 2" ASPHALT OR CONCRETE FINISHED GRADE 18" SQUARE CONCRETE ENCASEMENT (3500 P.S.I CONCRETE) 4" M A X . 18 "S TRAFFIC RATED CLEANOUT DETAIL NOT TO SCALE NOTE: ALL PENNSYLVANIA STORE LOCATIONS TO PROVIDE NON-REMOVABLE BOLLARDS AT FUEL CANOPY ONLY - STEEL PIPE AND FOOTER TO BE FILLED WITH CONCRETE IN LIEU OF PEA GRAVEL AS SHOWN. TYPICAL REMOVABLE BOLLARD DETAIL NOT TO SCALE SITE LIGHT POLE PROTECTION W/O CURB NOT TO SCALE 3" NON SHRINK GROUT, 1" SIKAFLEX - 2C POLYURETHANE SEALANT - REDWOOD (OR EQUIVALENT)PEA GRAVEL 6" SCH.40 STEEL PIPE 10" SCHEDULE 40 PVC SLEEVE 1" BELOW FINISHED SIDEWALK ELEVATION 1" SIKAFLEX - 2C POLYURETHANE SEALANT - REDWOOD 3" NON SHRINK GROUT CONCRETE PVC SLEEVE PAVING CUT 1" BELOW FINISHED SIDEWALK ELEVATION PRESCORE NEOPRENE TAPE 1/8" PLASTIC SLEEVE BY IDEAL SHIELD (OR EQUIVALENT) 1/2" BELOW FINISH INTO SEALANT PEA GRAVEL CAP/PLATE WELDED TO END OF BOLLARD SUBGRADE SIGN B GALVANIZED NUTS & BOLTS TYP. SIGN A DRILL 1/8"Ø HOLE IN BOLLARD SLEEVE 6" ABOVE GRADE EXPANSION JOINT REMOVABLE BOLLARD DETAIL AT HC PARKING NOT TO SCALE PROP. FREE AIR (CONTACT KATHY RETER @ ROYAL FARMS HQ.) PROP. CONCRETE CURB ALL SITES APPLICABLE FREE AIR & FREE AIR/ PAY VAC COMBO CONCRETE PAD LAYOUT ALL SITES DETAIL NOT TO SCALE 3'- 0 " 3'-0" LEAST TRAVELED DRIVE ISLE 3'- 0 " 3'-0" FREE AIR / PAY VACUUM (CONTACT KATHY RETER @ ROYAL FARMS HQ.) 1" D CONDUIT 4" FROM BACK SIDE TRAFFIC SIGN FOUNDATION DETAIL NOT TO SCALE TYPICAL 42" FENCE DETAIL NOT TO SCALE 4" DIA. 3000 PSI CONCRETE BASE FINISHED GRADE 30 " M I N SIGN SIGN POST GOVERNING CODE:IBC 2015 WIND VELOCITY =115 MPH EXPOSURE B SOIL BEARING CAPACITY =2,000 PSI LATERAL DESIGN PRESSURE =300 PSF/FT CONCRETE F'c =4,500 PSI (A/E) MAX W/C =0.45 24" DIA. 2' - 0 " T O 3 ' - 0 " 3" CL. CONC. COVER 7'- 0 " SE E E L E C T R I C A L / M E P PL A N S VA R I E S : M A X 2 0 ' - 0 " 5/8" CHAMFERED EDGE, ALL FOUR SIDES TOTAL MAX. AREA OF LIGHT FIXTURES = 4.0 SQ. FT. LIGHT POLE, SEE ELECTRICAL/MEP DWGS ANCHOR BOLTS, LEV. NUTS, ETC. BY MANUF., COORDINATE WITH LIGHT POLE SHOP DWGS. FINISH GRADE PVC CONDUIT DRILLED CONC. PIER REINF. w/ (8) #7 VERT., #4 TIES @ 16"o.c. NOT TO SCALE DRILLED CONC. PIER REINF. w/ (8) #7 VERT., #4 TIES @ 16"o.c. PLAN LIGHT POLE FOUNDATION DETAIL 2'-6" 1' - 3 " 1'-3"EMERGENCY STOP PROTECTIVE BOLLARD GAS CURB 1' - 6 " 4' 3' - 6 " 2" PROTECTIVE BOLLARD REMOVABLE BOLLARDS, TYP. 4'-0" â„„ â„„ SITE LIGHT POLE BASE W/O CURB PROTECTION 2'-0"2'-0" 4'- 0 " 2'- 0 " 2' - 0 " EMERGENCY STOP 3/4" SEAL-OFF CONDUIT STRAP 3/4" CONDUIT 6" BOLLARD 2' - 7 1 / 2 " 2'- 0 " MI N . GRADE LINE 1'- 2 7 / 8 " 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S C5.1 DE T A I L S 1 : 10 1 : 10 1 : 12 1 : 12 1 : 12 1 : 12 1 : 12 1 : 12 1 : 12 1 : 12 1 : 12 CURB HEIGHT PLUS RISE OF SIDEWALK CROSS SLOPE USE ONLY WHEN SPACE LIMITATIONS PROHIBIT THE CONSTRUCTION OF 1 : 12 OR FLATTER SLOPES. 6.0 FT. 5.0 FT. 4.0 FT. 3.0 FT. 5.0 FT. 4.2 FT. 3.3 FT. 2.5 FT. 5.0 FT. 4.2 FT. 3.3 FT. 2.0 FT. 1 : 10 1 : 8 6" 5" 4" 3" SIDE FLARE DIMENSION AT CURB (1 : 12) SIDE FLARE DIMENSION AT CURB (1 : 10) NOMINAL RAMP LENGTH MAX. RAMP SLOPE MAX. RISE OF RAMP CURB RAMP DIMENSIONS EXISTING CONDITION 5.0 FT. 4.2 FT. 8" 11.0 FT. 12.0 FT. 10.0 FT. 9.0 FT. 8.0 FT. 7.0 FT. 6.0 FT. 5.0 FT. 4.0 FT. 3.0 FT. 10.0 FT. 9.2 FT. 8.4 FT. 7.5 FT. 6.7 FT. 5.8 FT. 3.3 FT. 2.5 FT. 12.0 FT. 11.0 FT. 10.0 FT. 9.0 FT. 8.0 FT. 7.0 FT. 6.0 FT. 5.0 FT. 4.0 FT. 3.0 FT.1 : 12 12" 11" 10" 9" 7" 6" 5" 4" 3" SIDE FLARE DIMENSION AT CURB (1 : 12) SIDE FLARE DIMENSION AT CURB (1 : 10) NOMINAL RAMP LENGTH (1 : 12) MAX. RAMP SLOPE RISE OF RAMP CURB RAMP DIMENSIONS NEW CONSTRUCTION NOTE: 1.REFER TO LOCAL CODE REQUIREMENTS FOR LIMITATIONS ON RAMP SLOPE, LENGTH, RISE, AND SIDE FLARE. * * * ** ** TABLE A NOT TO SCALE 3500 P.S.I. CONCRETE SAND CUSHION 4" SEWER CLEANOUT CAP 6" PVC ENCASEMENT PIPE ASPHALT OR CONCRETE AS DETERMINED BY TRAFFIC SURFACE 4,000 P.S.I CONCRETE TRAFFIC RATED CLEANOUT COVER 2" ASPHALT OR CONCRETE FINISHED GRADE 18" SQUARE CONCRETE ENCASEMENT (3500 P.S.I CONCRETE) 4" M A X . 18 "S TRAFFIC RATED CLEANOUT DETAIL NOT TO SCALE 8'- 0 " 12 ' - 0 " TRASH ENCLOSURE DETAIL NOT TO SCALE 11'-0"11'-0" 24'-0" BRICK VENEER TO MATCH BUILDING CONTROL JOINT 8" REINFORCED CONCRETE SLAB 6" 1'11'11'1' 6"6" STD. 8 CUBIC YARD DUMPSTER STD. 8 CUBIC YARD DUMPSTER SEE STRUCTURAL FOR BOLLARD DETAIL. 2" DIA. GALVANIZED SLEEVE RECEIVING 1 3/8" DIA. DROP ROD @ GATE. (TYP. EA. SIDE. RECEIVING SLEEVE SHALL PROJECT 1" ABOVE FINISHED ASPHALT PAVING 1-3/8" DIA. DROP ROD 2" DIA. GALVANIZED RECEIVING SLEEVE 1" 9" TRUNCATED DOME DETAIL AT CURB RAMP NOT TO SCALE NOTE: 1. DETECTABLE WARNING SURFACE TO BE COLOR "BRICK RED" 2. DETECTABLE WARNING STRIP SHALL BE "CAST IN PLACE" TYPE DUMPSTER ENCLOSURE HT. = 8'-0" COMPACTED STONE BASE (CR-6) TO 95% DENSITY COMPACT SUB-GRADE OR STONE BASE TO 95% MODIFIED OR 98% STANDARD PROCTER HOT MIX ASPHALT SURFACE COURSE (2" MIN.) EXTEND 2' ON EACH SIDE OF TRENCH HOT MIX ASPHALT BINDER COURSE (4" MIN.) UTILITY TRENCH / PAVEMENT REPAIR DETAIL NOT TO SCALE SAW CUT EXIST. PAVING #57 STONE BEDDING PER MANUF. SPECIFICATIONS UTILITIES AS REQ'D REPAIRED PORTION SHALL MATCH EXIST. PAVING GRADES FUEL DISPENSER 10" MAX. 2" MA X TYPICAL MOUND-UP DETAIL @ FUEL DISPENSER NOT TO SCALE ELEVATION TOP OF PANEL 2' MIN OVERHANG 2' MIN OVERHANG SURFACE COURSE SURFACE COURSE 3" CL. 3'-6" 1'- 0 " 3'- 0 " M I N . 8'- 0 " M A X . 2'- 6 " L A P NOT TO SCALE DUMPSTER ENCLOSURE WALL & SLAB DETAIL #5 @ 32"o.c. STD. HOOK #6 DOWEL @ 16"o.c. (4) #5 CONT., 3" CL. CONC. COVER 12" CMU GROUTED SOLID BELOW GRADE, TYP. TYP. 6" CONC. SLAB ON GRADE REINF. w/ #4-16"o.c. EA. WAY, F'c=4,000 PSI A/E 6" FINISH GRADE VARIES, SEE CIVIL DWGS. 8" CMU REINFORCED w/ #6-16"o.c. VERT. REINF, FILL ALL CMU w/ PEA GRAVEL CONCRETE 1/2" EXPANSION JOINT PIPE BOLLARDS: 1. MINIMUM 6" DIA. SCH 80 PIPE FILLED WITH CONCRETE, COORDINATE WITH SITE/CIVIL DWGS. 2. MINIMUM 16"x16"x3'-0" TALL CONCRETE ENCASEMENT. STD 'DUR-O-WAL' REINF @ 16"o.c. STD 'DUR-O-WAL' REINF @ 16"o.c. VENEER TIES @ 16"o.c. HORIZ. & 16"o.c. VERT. VENEER TIES @ 16"o.c. HORIZ. & 16"o.c. VERT. BRICK VENEER, SEE ARCH DWGS. BRICK VENEER, SEE ARCH DWGS. 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S C5.2 DE T A I L S ROYAL FARMS TYPE LEANCON (LEFT) 4,710 S.F. E.J. - EXPANSION JOINT ALONG PERIMETER OF CONCRETE 8'8'8' 9' TYP 2'4'2'2'4'2'2'4'2' 10 ' TY P 9' TYP 1' T Y P 4.5' TYP4.25'4.25' 4.5'4.5' 4.5' TYP 4. 5 ' T Y P NOTE: E.J.= EXPANSION JOINT C.J. = CONTROL JOINT E.J. - EXPANSION JOINT AROUND WARNING SURFACE C.J. TYP C.J. TYP C. J . TY P C.J. TYP C. J . TY P C. J . TY P C. J . TY P E.J. - EXPANSION JOINT PERIMETER OF BUILDING QUICK REMOVABLE BOLLARD LOCATION, CONFIRM LOCATION W/RFDTE.J. - EXPANSION JOINT ALONG PERIMETER OF SIDE WALK AS S P E C I F I E D CONTROL JOINT SECTION NOT TO SCALE CONTROL JOINTS, 1" DEEP, 1/2" RADIUS AS S P E C I F I E D EXPANSION JOINT SECTION 1/2'' PREMOLDED EXP. JT. FOR FULL DEPTH OF CONCRETE NOT TO SCALE EXPANSION JOINT SEALANT AS S P E C I F I E D GR I D 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S KNOW WHAT'S BELOW CALL BEFORE YOU DIG! 1-800-632-4949 WWW.NC811.ORG R C5.3 FU T U R E R O A D W A Y I M P R O V E M E N T S P L A N 0 SCALE 1 inch = ft 10' 10 10'5' TYPICAL BOLLARD / CONCRETE JOINT LAYOUT NOT TO SCALE CONTROL JOINTS AT PUMPS AND MIDPOINTS BETWEEN PUMPS (TYP) 13' TYP 12' TYP 10 ' 12 ' TY P 10 ' 7' 7' 10 ' 15' TYP 12' TYP 15 ' TY P 12' TYP 12' TYP 12 ' - 6 " 12 ' - 6 " 15' TYP 30' 0" TYP 60 ' - 0 " TY P 30' 0" TYP 60 ' - 0 " TY P 30' 0" TYP 60 ' - 0 " TY P 30' 0" TYP 30' 0" TYP 30' 0" TYP 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S C5.4 DE T A I L S 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S C5.5 DE T A I L S TOP OF SILT FENCE MUST BE AT LEAST 1' ABOVE THE TOP OF WASHED STONE 30 " M I N . HE I G H T OF S T O N E BURY WIRE FENCE, FILTER FABRIC AND HARDWARE CLOTH IN TRENCH STEEL FENCE POST SET MAX 2' APART18" INTO SOLID GROUND SILT FENCE BURY 6" OF UPPER EDGE OF FILTER FABRIC IN TRENCH BURY WIRE FENCE AND HARDWARE CLOTH 3' FILTER FABRIC ON GROUND FILTER STONE FILTER OF 1" DIA. WASHED STONE SECTION VIEW FRONT VIEW SILT FENCE OUTLET NOT TO SCALE SHRUB PLANTING NOT TO SCALE UNDISTURBED SUBGRADE CREATE 3" WATER SAUCER FOR INDIVIDUALLY PLANTED SHRUBS, CREATE MULCHED BEDS FOR MASS PLANTING REMOVE BURLAP FROM TOP 1/3 OF ROOTBALL TRIPLE SHREDDED HARDWOOD BARK MULCH (NON -DYED) MIN 4"D. DO NOT PLACE MULCH IN CONTACT WITH THE TRUNK. TOP OF ROOTBALL SHALL BE 1" - 2" ABOVE SURROUNDING FIN. GRADE SELECTIVELY THIN ALL BRANCHING TO REMOVE DISCOLORED FOLIAGE MAINTAIN PLANT SHAPE EXCAVATE 2X ROOT BALL DIAMETER. PLACE BACKFILL MIXTURE IN 12" LIFTS & THOROUGHLY WATER BETWEEN LIFTS. TAMP SOIL AROUND ROOT BALL BASE FIRMLY WITH FOOT PRESSURE SO THAT ROOT BALL DOES NOT SHIFT. BACKFILL MIXTURE (REFER TO SPECS) PLACE IN 12" LIFTS & THOROUGHLY WATER BETWEEN LIFTS CONTAINER STOCK: REMOVE CONTAINER AND LOOSEN ROOTBALL PRIOR TO INSTALLATION LARGE AND SMALL TREE PLANTING NOT TO SCALE EACH TREE MUST BE PLANTED SUCH THAT THE TRUNK FLARE IS VISIBLE AT THE TOP OF THE ROOT BALL. TREES WHERE THE TRUNK FLARE IS NOT VISIBLE SHALL BE REJECTED. DO NOT COVER THE TOP OF THE ROOT BALL WITH SOIL. 4" HIGH TOPSOIL SAUCER BEYOND EDGE OF ROOT BALL. MULCH RING 8' DIA. REMOVE ALL TWINE, ROPE, WIRE AND BURLAP FROM TOP HALF OF THE ROOT BALL. IF THE PLANT IS SHIPPED WITH A WIRE BASKET AROUND THE ROOT BALL, CUT THE WIRE BASKET IN FOUR PLACES AND FOLD DOWN 8" INTO PLANTING HOLE. PLACE ROOT BALL ON UNEXCAVATED OR TAMPED SOIL. TAMP SOIL AROUND ROOT BALL BASE FIRMLY WITH FOOT PRESSURE SO THAT ROOT BALL DOES NOT SHIFT. NOTE: TREES SHALL BE STAKED ONLY IF DIRECTED BY THE OWNER. SET ROOT BALL FLUSH WITH FINISH GRADE TRIPLE SHREDDED HARDWOOD BARK MULCH (NON -DYED) MIN 4"D. DO NOT PLACE MULCH IN CONTACT WITH THE TREE TRUNK. EXCAVATE 2X ROOT BALL DIAMETER. PLACE BACKFILL MIXTURE IN 12" LIFTS AND THOROUGHLY WATER BETWEEN LIFTS. STANDARD FRAME, GRATE AND HOOD FOR USE ON STANDARD CATCH BASIN NOT TO SCALE PLAN FRAME, GRATE & HOOD ASSEMBLY B B D D 3'-7" C C 2' - 6 " A A NOTE: USE TYPE 'C' GRATE, UNLESS OTHERWISE INDICATED. SECTION - BB SECTION - AA SECTION - CC SECTION - DD 1 34"1 34" 1 12"58" 1 12" 2 34" 1 12"1 12" 1 34" 1" 2 34"1 12" FRAME PLAN 3'-0" 2' - 6 " 2'- 4 12" J J K K 3" 9" 9" 3" L M L M SECTION - RR R3" 4 58" 1 58" 1 14" 1"4 34" 34" 5 78"12" 3 12" 1116" 12" 58"1 12" SECTION - MM SECTION - LL SECTION - PP SECTION - NN 2 34"7" 2 18" 1" 1" 1" 1 38"1 38" P P34" 2 18" 7" 1 34" 1"N N SECTION - JJ SECTION - KK HOOD ELEVATION DETAIL #1 SEE DETAIL #1 1116" SLOT FOR 12" BOLT 7"58" 2'-0" 4 58" 58"4" 1 34" 4 34" 10" 10" 4"3" 34" 14" 2'-11 12" R R 1'-2"11"34"34" 1 12" 4" 3'- 78" 3'-0"3 12"3 12" 34"34" 34" TOP OF SILT FENCE MUST BE AT LEAST 1' ABOVE THE TOP OF WASHED STONE BURY WIRE FENCE, FILTER FABRIC AND HARDWARE CLOTH IN TRENCH SILT FENCE BURY 6" OF UPPER EDGE OF FILTER FABRIC IN TRENCH BURY WIRE FENCE AND HARDWARE CLOTH 3' FILTER FABRIC ON GROUND FILTER STONE FILTER OF 1" DIA. WASHED STONE SECTION VIEW FRONT VIEW SILT FENCE OUTLET NOT TO SCALE 8" MIN. 12' M I N . 50' NOT TO SCALE CLASS 'A' STONE 8" MIN. DEPTH NOTES: 1.PROVIDE TURNING RADIUS SUFFICIENT TO ACCOMMODATE LARGE TRUCKS. 2.LOCATE ENTRANCES TO PROVIDE FOR UTILIZATION BY ALL CONSTRUCTION VEHICLES. 3.MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR DIRECT FLOW OF MUD ONTO STREETS. PERIODIC TOPDRESSING WITH STONE WILL BE NECESSARY. 4.ANY MATERIAL TRACKED ONTO THE ROADWAY MUST BE CLEANED UP IMMEDIATELY. 5.LOCATE GRAVEL CONSTRUCTION ENTRANCE AT ALL POINTS OF INGRESS AND EGRESS UNTIL SITE IS STABILIZED. PROVIDE FREQUENT CHECKS OF THE DEVICE AND TIMELY MAINTENANCE. 6.NUMBER AND LOCATION OF CONSTRUCTION ENTRANCES TO BE DETERMINED BY THE ENGINEER. 7.USE CLASS 'A' STONE OR OTHER COARSE AGGREGATE APPROVED BY THE ENGINEER. 8.INSTALL CONSTRUCTION ENTRANCES IN A WAY TO PREVENT VEHICLES FROM BYPASSING CONSTRUCTION ENTRANCE LEAVING PROJECT SITE. NOTE: PLACE FILTRATION GEOTEXTILE BENEATH STONE PU B L I C R O A D (CONSTRUCT IN ACCORDANCE WITH NCDOT DETAIL No. 1607.01) NCDOT TEMPORARY GRAVEL CONSTRUCTION ENTRANCE WIRE FABRIC UV RESISTANT GEOTEXTILE FABRIC TAMPED BACKFILL 6' MAX. EXTRA STRENGTH FABRIC W/O WIRE FENCE 12 GAUGE, 4"x 4" WELDED WIRE FABRIC 8' MAX. STANDARD STRENGTH FABRIC W/ WIRE FENCE 24 " FILL S L O P E 36 " GROUND LINE 24 " NOTES: 1. INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. 2. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. 3. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. 4. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. STEEL POST TEMPORARY SILT FENCE NOT TO SCALE 8" DOWN & 4" FORWARD ALONG THE TRENCH NOTES: STRAW BALE STRAW BALE (TYP) 10 mil PLASTIC LINING VARIES 10' MINIMUM BINDER WIRE NATIVE MATERIAL (OPTIONAL) STAPLES(2 PER BALE) WOOD ORMETAL STAKES (2 PER BALE) SECTION B-B 10 mil PLASTIC LINING B B PLAN CONCRETE WASHOUT SIGN DETAIL (OR EQUIVALENT) PLYWOOD 48"X24" PAINTED WHITE BLACK LETTERS6" HEIGHT LAG SCREWS 36" 36" TYPE "ABOVE GRADE" WITH STRAW BALES 2" 8"1.12" DIASTEEL WIRE STAPLE DETAIL CONCRETE WASHOUT 10' MINIMUM VARIES 10 mil PLASTIC LINING PLAN NOT TO SCALE 10 mil PLASTIC LINING WOOD FRAME SECURELY FASTENED AROUND ENTIRE PERIMETER WITH TWO STAKES TWO-STACKED 2X12 ROUGH WOOD FRAME STAKE(TYP) TYPE "ABOVE GROUND" WITH WOOD PLANKS SECTION B-B B B VARIES 10' MINIMUM AA 10 mil PLASTIC LINING 10 mil PLASTIC LINING SANDBAG BERM BERM 3' LATH AND FLAGGING ON 3 SIDES PLAN NOT TO SCALE SECTION A-A SANDBAG TYPE "BELOW GRADE" WOOD POST 3.5"X3.5"X8' 1.ACTUAL LAYOUT TO BE DETERMINED IN THE FIELD. 2.A CONCRETE WASHOUT SIGN SHALL BE INSTALLED WITHIN 30' OF THE TEMPORARY CONCRETE WASHOUT FACILITY. 3. MATERIALS USED TO CONSTRUCT TEMPORARY CONCRETE WASHOUTFACILITIES SHALL BE REMOVED FROM THE SITE OF THE WORK AND DISPOSED OF OR RECYCLED. 4. HOLES, DEPRESSIONS OR OTHER GROUND DISTURBANCE CAUSED BY THE REMOVAL OF THE TEMPORARY CONCRETE WASHOUT FACILITIES SHALL BE BACKFILLED, REPAIRED, AND STABILIZED TO PREVENT EROSION. CONCRETE WASHOUT NOT TO SCALE MAXIMUM POST SPACING 4 FT. SECTION A-A MULTI-DIRECTIONAL FLOW CONTROL STONESEDIMENT 2' 2' 1'-6" A DIMENSION VARIABLE AVERAGE BOX 2' 6" 12" 1/4" WIRE MESH A NOTES: 1. SEDIMENT CONTROL STONE SHALL BE NO. 5 OR NO. 57 AND SHALL BE PAID FOR AT THE CONTRACT UNIT PRICE PER TON "SEDIMENT CONTROL STONE." 2. WIRE MESH SHALL BE HARDWARE CLOTH 23 GAUGE MIN. AND SHALL HAVE 1/4 INCH MESH OPENINGS.TOP OF WIRE MESH SHALL BE A MINIMUM OF ONE FOOT BELOW THE SHOULDER OR ANY DIVERSION POINT. 3. STEEL POST SHALL BE 5 FT. IN HEIGHT, BE INSTALLED 1.5 FT. DEEP MINIMUM, AND BE OF THE SELF-FASTENER ANGLE STEEL TYPE. 4. WOOD POST SHALL BE 6 FT. IN HEIGHT, BE INSTALLED TO 1.5 FT. DEEP MINIMUM, AND BE 3 INCHES IN DIAMETER. POST SPACING SHALL BE A MAXIMUM OF 4 FT. 5. INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (12 INCH OR GREATER) RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER OBJECTS TO PROVIDE ADEQUATE FLOW FOR SUBSEQUENT RAINS. TAKE CARE NOT TO DAMAGE OR UNDERCUT THE WIRE MESH DURING SEDIMENT REMOVAL. REPLACE STONE AS NEEDED. FILTERED WATER ROCK INLET SEDIMENT TRAP NOT TO SCALE TREE PROTECTION FENCING / BARRIER FENCING NOT TO SCALE SIGNAGE: TREE PROTECTION SIGNAGE SHALL BE PROVIDED ON THE FENCE AT 100' ON CENTER. PROVIDE AT LEAST ONE SIGN PER PROTECTED AREA. 40" MIN. 18 " M I N . NO TRESSPASSING TREE PROTECTION AREA NOTES: 1.FENCING SHALL BE INSTALLED AFTER CLEARING AND PRIOR TO COMMENCEMENT OF GRADING. 2.INSTALL FENCING AS INDICATED ON THE DRAWINGS OR AS DIRECTED BY THE ENGINEER. 3.ALL TREES TO BE SAVED IN AREAS TO BE GRADED SHALL RECEIVE FENCING. 4.CONTRACTOR IS RESPONSIBLE FOR MAINTENANCE OF THE FENCING UNTIL ALL SITE WORK IS COMPLETED. 5.FENCING SHALL BE REMOVED PRIOR TO THE FINAL SITE INSPECTION. 6.NO GRADING, PUMPING, STORAGE, PEDESTRIAN OR VEHICULAR TRAFFIC ALLOWED IN FENCED AREAS. EXISTING GRADE 2'- 0 " M I N . 4' - 0 " M I N . 10'-0" MAX. ORANGE SAFETY FENCE FABRIC ATTACH FABRIC WITH PREFORMED HOOKS TO METAL POSTS 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S C6.0 DE T A I L S 3:1 (MA X . ) TEMPORARY STOCKPILE 3:1 (M A X . ) TEMPORARY STOCKPILE NOT TO SCALE INSTALL TEMPORARY SILT FENCE WHERE NECESSARY TO RETAIN SEDIMENT 10 ' M A X . H E I G H T EXISTING GRADE TEMPORARILY SEED AS SOON AS POSSIBLE (NO MORE THAN 21 CALENDAR DAYS AFTER FORMATION OF THE STOCKPILE.) IF STOCKPILE WILL NOT BE USED WITHIN 90 DAYS STABILIZE WITH PERMANENT VEGETATION. NCG01 GROUND STABILIZATION AND MATERIALS HANDLING EFFECTIVE: 04/01/19 GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH THE NCG01 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCG01 Construction General Permit (Sections E and F, respectively). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below: POLYACRYLAMIDES (PAMS) AND FLOCCULANTS 1.Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2.Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3.Apply flocculants at the concentrations specified in the NC DWR List of Approved PAMS/Flocculants and in accordance with the manufacturer's instructions. 4.Provide ponding area for containment of treated Stormwater before discharging offsite. 5.Store flocculants in leak-proof containers that are kept under storm-resistant cover or surrounded by secondary containment structures. HAZARDOUS AND TOXIC WASTE 1.Create designated hazardous waste collection areas on-site. 2.Place hazardous waste containers under cover or in secondary containment. 3.Do not store hazardous chemicals, drums or bagged materials directly on the ground. EQUIPMENT AND VEHICLE MAINTENANCE 1.Maintain vehicles and equipment to prevent discharge of fluids. 2.Provide drip pans under any stored equipment. 3.Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4.Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible). 5.Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6.Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1.Never bury or burn waste. Place litter and debris in approved waste containers. 2.Provide a sufficient number and size of waste containers (e.g dumpster, trash receptacle) on site to contain construction and domestic wastes. 3.Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 4.Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5.Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers. 6.Anchor all lightweight items in waste containers during times of high winds. 7.Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow. 8.Dispose waste off-site at an approved disposal facility. 9.On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1.Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2.Locate paint washouts at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3.Contain liquid wastes in a controlled area. 4.Containment must be labeled, sized and placed appropriately for the needs of site. 5.Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1.Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2.Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas. 3.Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit. HERBICIDES, PESTICIDES AND RODENTICIDES 1.Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2.Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning. 3.Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4.Do not stockpile these materials onsite. CONCRETE WASHOUTS 1.Do not discharge concrete or cement slurry from the site. 2.Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility. 3.Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence. 4.Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail. 5.Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6.Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive spills or overflow. 7.Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout. Additional controls may be required by the approving authority. 8.Install at least one sign directing concrete trucks to the washout within the project limits. Post signage on the washout itself to identify this location. 9.Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp, sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary products, follow manufacturer's instructions. 10.At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance caused by removal of washout. EARTHEN STOCKPILE MANAGEMENT 1.Show stockpile locations on plans. Locate earthen-material stockpile areas at least 50 feet away from storm drain inlets, sediment basins, perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available. 2.Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3.Provide stable stone access point when feasible. 4.Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs. A A BELOW GRADE WASHOUT STRUCTURE 1:1SIDE SLOPE(TYP.) 10 MILPLASTICLINING 3'- 0 " MIN . & X ' MA X . SECTION A-A NOT TO SCALE ABOVE GRADE WASHOUT STRUCTURE NOT TO SCALE PLAN SECTION B-B HIGHCOHESIVE &LOW FILTRATIONSOIL BERM 8" 6" 2' HIGHCOHESIVE &LOW FILTRATIONSOIL BERM1:1 SIDE SLOPE(TYP.) 10 MILPLASTIC LINING B B 3'-0 " MIN . & X ' MA X . A SANDBAGS (TYP.)OR STAPLES SANDBAGS (TYP.)OR STAPLES SANDBAGS (TYP.) OR STAPLES SANDBAGS (TYP.) OR STAPLES NOTES:1. ACTUAL LOCATION DETERMINED IN FIELD 2. THE CONCRETE WASHOUT STRUCTURES SHALL BEMAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES 75% OF THE STRUCTURES CAPACITY. 3.CONCRETE WASHOUT STRUCTURE NEEDS TO BECLEARY MARKED WITH SIGNAGE NOTING DEVICE. NOTES: 1. ACTUAL LOCATION DETERMINED IN FIELD 2. THE CONCRETE WASHOUT STRUCTURESSHALL BE MAINTAINED WHEN THE LIQUIDAND/OR SOLID REACHES 75% OF THESTRUCTURES CAPACITY TO PROVIDEADEQUATE HOLDING CAPACITY WITH A MINIMUM 12 INCHES OF FREEBOARD. 3.CONCRETE WASHOUT STRUCTURE NEEDSTO BE CLEARY MARKED WITH SIGNAGE NOTING DEVICE. ONSITE CONCRETE WASHOUT STRUCTURE WITH LINER CONCRETEWASHOUT CONCRETEWASHOUT PLAN CLEARLY MARKED SIGNAGE NOTING DEVICE (18"X24" MIN.)CLEARLY MARKED SIGNAGE NOTING DEVICE (18"X24" MIN.) SILT FENCE 10'MIN 10'MIN SECTION E: GROUND STABILIZATION Required Ground Stabilization Timeframes Note: After the permanent cessation of construction activities, any areas with temporary ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last land disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved. Site Area Description Timeframe variations -7 days for perimeter dikes, swales, ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed unless there is zero slope Stabilize within this many calendar days after ceasing land disturbance 7 7 7 14 None None (a)Perimeter dikes, swales, ditches, and perimeter slopes (b)High Quality Water (HQW) Zones (c)Slopes steeper than 3:1 If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed (d)Slopes 3:1 to 4:1 (e)Areas with slopes flatter than 4:1 14 -7 days for slopes greater than 50' in length and with slopes steeper than 4:1 -7 days for perimeter dikes, swales, ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed NCG01 SELF-INSPECTION, RECORDKEEPING AND REPORTING EFFECTIVE: 04/01/19 PART III SELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION A: SELF-INSPECTION Self-inspections are required during normal business hours in accordance with the table below. When adverse weather or site conditions would cause the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which it is safe to perform the inspection. In addition, when a storm event of equal to or greater than 1.0 inch occurs outside of normal business hours, the self-inspection shall be performed upon the commencement of the next business day. Any time when inspections were delayed shall be noted in the Inspection Record. NOTE: The rain inspection resets the required 7 calendar day inspection requirement. PART III SELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION B: RECORDKEEPING 1.E&SC Plan Documentation The approved E&SC plan as well as any approved deviation shall be kept on the site. The approved E&SC plan must be kept up-to-date throughout the coverage under this permit. The following items pertaining to the E&SC plan shall be documented in the manner described: 2. Additional Documentation In addition to the E&SC Plan documents above, the following items shall be kept on the site and available for agency inspectors at all times during normal business hours, unless the Division provides a site-specific exemption based on unique site conditions that make this requirement not practical: (a)This general permit as well as the certificate of coverage, after it is received. (b)Records of inspections made during the previous 30 days. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically-available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard-copy records. (c)All data used to complete the Notice of Intent and older inspection records shall be maintained for a period of three years after project completion and made available upon request. [40 CFR 122.41] PART III SELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1.Occurrences that must be reported Permittees shall report the following occurrences: (a)Visible sediment deposition in a stream or wetland. (b)Oil spills if: ·They are 25 gallons or more, ·They are less than 25 gallons but cannot be cleaned up within 24 hours, ·They cause sheen on surface waters (regardless of volume), or ·They are within 100 feet of surface waters (regardless of volume). (a)Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S. 143-215.85. (b)Anticipated bypasses and unanticipated bypasses. (c)Noncompliance with the conditions of this permit that may endanger health or the environment. 2.Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Division's Emergency Response personnel at (800) 662-7956, (800) 858-0368 or (919) 733-3300. NOTES: 1.REMOVE ANY EXISTING VEGETATION AND SCARIFY OR BENCH ADJACENT SOILS PRIOR TO PLACING BERM. 2.BERM MATERIALS MUST BE ADEQUATELY COMPACTED AND IMMEDIATELY STABILIZED. 3.DIVERSION DITCHES/BERMS MUST BE IMMEDIATELY STABILIZED TO PREVENT EROSION AND TRANSPORT OF SEDIMENT. 4.FOLLOW 02300 EARTHWORK SPECIFICATION. TYPICAL VEE SHAPED DIVERSION CHANNEL LINED TO PREVENT EROSION (SEE TABLE IN THIS DETAIL) NOTE 1 DESIGN FLOW DEPTH 12" MIN. FREEBOARD W NOTE 2 3 1 TYPICAL PARABOLIC DIVERSION CHANNEL LINED TO PREVENT EROSION (SEE TABLE IN THIS DETAIL) NOTE 1 DESIGN FLOW DEPTH 12" MIN. FREEBOARD W NOTE 2 3 1 CHANNEL LINED TOPREVENT EROSION (SEE TABLE IN THIS DETAIL) NOTE 1 DESIGN FLOW DEPTH 12" MIN. FREEBOARD W NOTE 2 3 1 TYPICAL TRAPEZOIDAL DIVERSION LONG I T U D I N A L S L O P E DIVERSION DITCH NOT TO SCALE STAKE TOSUPPORT WIRE SUPPORT ROPE TO WIRETO PREVENT SAGGING 4'MAX SUPPORT POST 24" INTO BOTTOM OR SIDES DESIGN LIFE OF FABRIC IS 6-12 MONTHS COIR MESH OR JUTE, TRENCHEDINTO BOTTOM AND SIDE CO M P A C T E D EAR T H E N D A M 3' MIN TEMPORARY RISER OUTLET PIPE 5' CRESTWIDTH 3:1 SIDE SLOPES SKIMMER TETHER EXTEND BAFFLES UP SIDESAS TO NOT ALLOW FLOWAROUND THE ENDS. SECOND CHAMBER25% OF SURFACE AREA FIRST CHAMBER 25% OF SURFACE AREA INLET ZONE35% OF SURFACE AREA STONE ENERGY DISSIPAT0R INLET F L O W (PIPE O R D I T C H ) BAFFLE (TYP.) PERSPECTIVE VIEW SKIMMER BASIN BAFFLE DETAIL NOTE: BAFFLES TO BE REMOVED UPON SITE STABILIZATION AND PRIOR TO EXCAVATION FOR FINAL CONTOURSFOR WET DETENTION POND. SKIMMER SEDIMENT BASIN CROSS SECTION VIEW COIR MESH OR JUTE BAFFLES INLET FLOW (PIPE OR DITCH) DEWATERINGZONE FILTER FARBRIC SEDIMENT STORAGE ZONE STONE PAD OUTLET PIPE TEMPORARY OUTLET STRUCTURE TETHER NOTES: 1.SKIMMER IS TO BE A SURFACE DEWATERINGDEVICE SUCH AS BMP SKIMMER OR APPROVED DEVICE. 2.SKIMMER SHOULD RISE TO LEVEL OF WEIR HEIGHT IN TEMPORARY BASIN OR TO RISERINLET. 3.ROPE ATTACHED TO SKIMMER TO HELP KEEP SKIMMER CLEAN. 4.SKIMMER SHALL BE 2" SKIMMER WITH ORIFICE SIZE INDICATED ON SHEET C-4 ASMANUFACTURED BY J.W. FAIRCLOTH & SON, INC. (919) 732-1244 OR 2" SKIMMER MANUFACTURED BY IAS, LLC (336) 698-4275. WATER ENTRY UNIT WITH TRASH SCREEN ORIFICE OPENING INSIDE THE HORIZONTAL TUBE WITH A CONSTANT HYDRAULIC HEAD SCHEDULE 40 PVC PIPE (BARREL OR ARM) FLEXIBLE HOSE TOP VIEW PVC VENT PIPE WATER ENTRY UNIT FLOAT END VIEW EARTHEN EMBANKMENT EMERGENCY SPILLWAY TOP OF PROPOSEDOUTLET STRUCTURE OUTLET PIPE SIDE VIEW STONE PAD SCHEDULE 40 PVC PIPE (BARREL OR ARM) L= MIN. 5' FLEXIBLE HOSE MUST BE SECURELY FASTENED TO THE DISCHARGEOPENING. FLEXIBLE HOSE FLOAT PVC VENT PIPE SKIMMER DISCHARGE SYSTEM WITH OUTLET STRUCTURE NOT TO SCALE NOTES: 1.FILTER TYPES SHALL BE APPROVED BY THE INSPECTOR PRIOR TO INSTALLATION.2.FILTER BAGS MAY BE REMOVED WHEN SITE IS STABILIZED AT THE DIRECTION OF THE INSPECTOR. 3.FILTER BAGS SHALL BE CLEANED OR REPLACED ON A REGULAR BASIS (NOT BE MORE THAN HALF FULL AT ANY TIME). 4.FILTER BAGS SHALL NOT BE ALLOWED IN EXISTING NCDOT ROADS. FILTER BAG INLET PROTECTION NOT TO SCALE INSTALLATIONSECTION GRATE HOOD EXPANSION RESTRAINT GRATE DEFLECTOR CATCH BASIN DUMP LOOPS FILTER BAG 1" REBAR FOR BAG REMOVE FROM INLET OULET MAINTENANCE: INSPECT FILTER BAG AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL EVENT (12 INCH OR GREATER) AND CLEAN AS NEEDED. REMOVE SEDIMENT AND CLEAN FILTER WHEN FILTER BAG IS 1/2 FULL OF SEDIMENT TO MAINTAIN EFFICIENCY AND FLOW THROUGH FILTER BAG. ONCE CONTRIBUTING DRAINAGE AREA HAS BEEN ADEQUATELY STABILIZED ANDAPPROVAL OF INSPECTOR HAS BEEN GRANTED, REMOVE SEDIMENT FILTER BAG FROM INLET. FILTER BAG 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S C6.1 DE T A I L S CLASS "D" FINISHED GRADE BACKFILL PIPE 12" MIN. 4" MIN. TRENCH SECTION DETAIL FOR THE INSTALLATION OF PVC GRAVITY STORM DRAIN & SANITARY SEWER PIPING (NOT TO SCALE) GRANULAR EMBEDMENT SELECT BACKFILL CLASS "F" FINISHED GRADE EMBEDMENT BACKFILL PIPE 12" MIN. TRENCH SECTION DETAIL FOR THE INSTALLATION OF REINFORCED CONCRETE PIPE (NOT TO SCALE) 6'-0"6'-0"5'-0" 1:12 MAX SLOPE 1:12 MAX SLOPE (C) SIDEWALK RAMPS ACCESSIBLE RAMPS RAMP FLOOR DETAIL INSET A SEE NOTE PLAN SECTION 0. 2 " O. C . 2. 3 5 " O.C. 2.35" TAPER 6" CURB HEAD TO BE FLUSH WITH CONC. WALK CURB HEAD (6" WIDTH & 6" HEIGHT) 2' - 0 " 7' CONCRETE SIDEWALK 7' CONCRETE SIDEWALK 6"-8" (NOT TO SCALE) NOTES: 1. WARNING SURFACE TO BE RED IN COLOR SLIP-RESISTANT WARNING SURFACE 0.9" DIA. RAISED DOMES 0.9" DIA. RAISED DOMES NOTE: RAMPS MUST COMPLY WITH NATIONAL AND LOCAL CODES SEE INSET 'A' AND NOTE NOTE: RAMP FLOOR SHALL BE CONSTRUCTED TO CONTRAST VISUALLY WITH ADJOINING SURFACES. WARNING SURFACE TO BE RED IN COLOR. THIS POINT TO BE FLUSH WITH PAVEMENT NOT TO SCALE 5' M I N I M U M WIDTH VARIES (5' MINIMUM) CODE REQUIRED EXIT DOOR (WIDTH VARIES) 14" PER 1' MAXIMUM SLOPE IN ANY DIRECTION REQUIRED BUILDING EXIT DOOR ACCESSIBLE GRADES DETAIL 0.5' MINIMUM 1.5' MIN. *REFER TO ARCHITECTURAL DRAWING(S) FOR REQUIRED EXIT DOOR LOCATION(S) ACCESSIBLE PARKING DETAIL TYPICAL PARKING DETAIL - (REFER TO PLAN) NOT TO SCALE NOTE: HANDICAP SPACES FOR PHYSICALLY HANDICAPPED PERSONS SHALL BE IDENTIFIED BY ABOVE-GRADE SIGNS STATING "RESERVED PARKING". REFER TO "ACCESSIBLE PARKING SIGN" DETAIL. "HANDICAP PARKING"HANDICAP RAMP "HANDICAP PARKING" VAN ACCESSIBLE SIGN CONCRETE SIDEWALK 11'5'8' 18 ' WHEELSTOP (TYP) CONCRETE PAVING14" P E R 1 ' M A X 14" PER 1' MAX 2' CURB RAMPS - DIRECTIONAL RAMPS NOT TO SCALE 6"x12" CONCRETE CURB TYPE 1 REFER TO ROADWAY STANDARD DRAWING NUMBER 848.05 SHEET 3 OF 3 FOR ALL RAMP NOTES CONCRETE DEPRESSED CURB DETECTABLE WARNING SURFACE SEE R.S.D.N. 848.05 4'-0" MIN. 5'-0" MAX GRADE BREAKDEPRESSED 2'-6" CURB & GUTTER 8.33% (12:1) MAX SLOPE NOTES: 1.8.33% (12:1) MAX RAMP SLOPE 2.CROSS SLOPE: 2.00% 3.CURB RAMPS REQUIRE A (4'-0") MINIMUM LANDING WITH A MAXIMUM CROSS SLOPE AND LONGITUDINAL SLOPE OF 2.00% WHERE PEDESTRIANS PERFORM TURNING MANEUVERS. SLOPE TO DRAIN TO CURB. SLOPE: ZERO - 2.00% SIDEWALK 5' MIN.1 3 ACCESSIBLE PARKING SIGN NOT TO SCALE NOTES: 1.MOUNT POST IN SIDEWALK. PROVIDE PROTECTION FOR POST. 2.PAINT STEEL/METAL POST TO MATCH BUILDING. PAVEMENT/GRASS MUTCD R7-8D 12"x9" MUTCD R7-8 12"x18" MUTCD R7-8A 12"x6" PAINT (OWNER TO SELECT COLOR) VAN ACCESSIBLE SIGNNOTE: SIGN TO MEET ALL STATE, LOCAL AND ADA REQUIREMENTS 12" 18 " 6" 9" 7'- 0 " 9" 2" 18 " 2" 6" 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S C6.2 DE T A I L S 15' TRANSITION TO FLUSH FLOW LINE OF GUTTER (NOT TO SCALE) GUTTER RISES TO MATCH TOP OF CURB GRADE TOP OF CURB ELEVATION NOTE: THIS DETAIL ILLUSTRATES THE TRANSITION FROM STANDARD CURB & GUTTER - W/ 6" ELEVATION DIFFERENCE BETWEEN TOP OF CURB AND FLOWLINE, TO FLUSH CONDITION - W/ TOP OF CURB AND FLOWLINE OF GUTTER AT SAME ELEVATION. TYPICALLY USED AT ENTRANCE/EXIT TO CAR WASH AND AT SIDEWALK/CURB & GUTTER TRANSITION POINTS ALONG BUILDING. 15' TRANSITION(TYP) - AT ENTRANCE 6"5" TOP OF CURB ELEVATION = TOP OF WALK ELEVATION = FRONT OF GUTTER = FLOW LINE ELEVATION TOP OF CURB ELEVATION ISOMETRIC VIEW PROFILE FLOW LINE OF GUTTER FRONT OF GUTTER FRONT OF GUTTER 24" TOP OF CURB ELEVATION = TOP OF WALK ELEVATION = FRONT OF GUTTER = FLOW LINE ELEVATION 24" CURB AND GUTTER (TYP.) CURB AND GUTTER TO FLUSH PAVING TRANSITION STANDARD CATCH BASIN FRAME IN CURB AND GUTTER NOT TO SCALE FRAME, GRATE, AND HOOD 5' M I N . 5' M I N . 12" EXPANSION JOINT 12" EXPANSION JOINT CURB AND GUTTER CL 8" 7" 12" VARIAB L E CURB AND GUTTER TO FLUSH PAVING TRANSITION NOT TO SCALE TOP OF CURB ELEVATION = TOP OF WALK ELEVATION = FRONT OF GUTTER = FLOW LINE ELEVATION PROFILE ISOMETRIC VIEW 15' TRANSITION (TYP) - AT ENTRANCE TOP OF CURB ELEVATION FRONT OF GUTTER FLOW LINE OF GUTTER 6"5" TOP OF CURB ELEVATION = TOP OF WALK ELEVATION = FRONT OF GUTTER = FLOW LINE ELEVATION TRANSITION TO FLUSH GUTTER RISES TO MATCH TOP OF CURB GRADE FRONT OF GUTTER TOP OF CURB ELEVATION FLOW LINE OF GUTTER 24" CURB AND GUTTER (TYP) NOTE: THIS DETAIL ILLUSTRATES THE TRANSITION FROM STANDARD CURB & GUTTER - W/ 6" ELEVATION DIFFERENCE BETWEEN TOP OF CURB AND FLOWLINE, TO FLUSH CONDITION - W/ TOP OF CURB AND FLOWLINE OF GUTTER AT SAME ELEVATION. TYPICALLY USED AT ENTRANCE/EXIT TO CAR WASH AND AT SIDEWALK/CURB & GUTTER TRANSITION POINTS ALONG BUILDING. 24" 15' CURB TAPER DETAIL NOT TO SCALE 2' EXPANSION JOINT (SEE DETAIL) 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S C6.3 DE T A I L S 2'-0" GRADE FINISHED SEWER SERVICE PIPE AS SHOWN ON PLANS OR SPEC. CLEAN OUT TO BE INSTALLED IF SPECIFIED ON PLANS AND IS IN THE BID SCHEDULE CONCRETE CLEAN OUT RING GRAVITY SEWER CLEAN-OUT NOT TO SCALE 45° BEND BOLTED PLUG VARIES SEE SITE PIPING FOR SIZES CONC. COLLAR (SEE DETAIL) PIPE CONTINUATION FOR ON LINE C.O. FITTING AS REQ'D SEE SITE PIPING FLOW EXTERIOR CLEAN-OUT DETAIL NOT TO SCALE BLDG 5'-0" 3' - 5 ' D E E P FLOW SEE SITE PIPING FOR SIZES COMBINATION WYE AND 18 BEND CLEAN OUT CAP TO BE SET 1" ABOVE FINAL GRADE STUB OUT 1' PAST WYE AND INSTALL RUBBER TEST CAP NO. TP6 AS MANUFACTURED BY JONES MANUFACTURING CO. OR EQUIVALENT SEWER SERVICE CONNECTION DETAIL NOT TO SCALE STANDARD BRICK CATCH BASIN 15" THROUGH 54" PIPE NOT TO SCALE NOTES: 1.MORTAR JOINTS 1/2" ± 1/8" THICK. CLASS "AA" CONCRETE TO BE USED. 2.THE POURING OF FLOOR SLAB TO BE ACCOMPLISHED BY FORMING. 3.ALL CATCH BASINS OVER 3' 6" IN DEPTH SHALL BE PROVIDED WITH STEPS 1' 2" ON CENTERS. 4.STEPS SHALL BE IN ACCORDANCE WITH STD No. 25.12. 5.CONCRETE BRICK MAY BE USED IN LIEU OF CLAY BRICK. JUMBO BRICK WILL BE PERMITTED. 6.FOR 8' 0" IN HEIGHT OR LESS USE 8" WALL. OVER 8' 0" IN HEIGHT USE 12" WALL TO 6' 0" FROM TOP OF WALL, AND 8" WALL FOR THE REMAINING 6' 0". 7.LEAVE WEEP HOLES AS DIRECTED BY THE ENGINEER. PLAN Y Y X X A B 2" BACK OF CURB SECTION - XX FRAME, GRATE & HOOD 12" B 8"8" D 6" HI D 8" 6" 6" HI C B8"8" HI + 6 END ELEVATION WHERE 30" TO 36" PIPE IS USED SECTION - JJ H2 12" E SECTION - YY OUTLET 6" HI 8"8" 8"6"6" A D SIDE ELEVATION WHERE 42" TO 54" PIPE IS USED SECTION - MM 8" 6" 6" HI E D G A STEP 8"8" HI + 6 H2 PLAN PLAN F E Y Y A B F E M MBA STANDARD BRICK CATCH BASIN 15" THROUGH 54" PIPE NOT TO SCALE ELEVATION NORMAL CURB AND GUTTER ON STEEP GRADE USE ON FLAT GRADE 2% AND OVER NORMAL GUTTER LINE 12"5'-0" DEPRESSED GUTTER LINE 8"6" 10 " M A X . SECTION - SS F 6" 1 12" 3"3" #4 BARS "U" EQUALLY SPACED ELEVATION SECTION - RR PLAN CURB AND GUTTER W/ CATCH BASIN ON STEEP GRADE PLAN OF TOP SLAB NORMAL CURB AND GUTTER ON LIGHT GRADE USE ON FLAT GRADE 2% AND UNDERE 6" 1 12" #8 BARS "W" #4 BARS "U" #4 BARS "V" 6"6" 8" DEPRESSED GUTTER LINE 3'-0"3'-0" 5'-0" 5'-0"5'-0" FLOW R R S S E 3"6" 1 12" #4 BARS "V" EQUALLY SPACED #8 BARS "W" EQUALLY SPACED F #4 B A R S " U " EQ U A L L Y S P A C E D 3" 3" 54" 48" 42" 36" 30" 24" 18" 15" D PIPE 3'-0" A SPAN 2'-2" B WIDTH C WIDTH 5'-7" 5'-0" 4'-5" G SPAN 5'-4" 4'-10" 4'-4" 3'-8" 3'-2" 3'-4" 2'-10" 2'-6" MIN. H' HEIGHT --- HEIGHT H2 --- --- V E ARIABL --- --- --- --- --- --- --- --- --- --- --- 3'-10" 3'-4" 3'-0"2'-2" DIMENSIONS OF BOX AND PIPE COVER DIMENSIONS 3'-3" 2'-8" 2'-1" E --- --- --- 1'-10" 2'-4" 3'-6" 3'-6" 3'-6" F --- --- --- 4'-4" 4'-4" 4 4 4 No. --- --- --- 4 4 3'-0" 2'-6" 1'-9" LENGTH --- --- --- 1'-6" 2'-0" 6 4 3 No. --- --- --- 3 4 3'-3" 3'-3" 3'-3" L --- --- --- 4'-1" 4'-1" 3 3 3 No. --- --- --- 3 3 3'-3" 3'-3" 3'-3" L --- --- --- 4'-1" 4'-1" REINFORCEMENT BARS-U BARS-V BARS-W TOTAL LBS 48 40 38 --- --- --- 45 49 CUBIC YARDS OF CONCRETE IN BOX H' BRICK MASONRY CU. YDS PER FT. OF HEIGHT 0.321 ABOVE H2 0.321 ABOVE MINIMUM H' DIMENSIONS AND QUANTITIES FOR BRICK CATCH BASINSTANDARD BRICK 15"-54" PIPE 2.146 1.811 0.802 0.909 1.070 1.306 1.586 2.510 0.583 0.508 0.281 0.281 0.281 0.521 0.602 0.659 0.410 0.373 0.281 0.281 0.281 0.374 0.415 0.448 0.173 0.135 --- --- --- 0.147 0.187 0.211 TOTALFLOORTOP SLAB STANDARD FRAME, GRATE AND HOOD FOR USE ON STANDARD CATCH BASIN NOT TO SCALE PLAN FRAME, GRATE & HOOD ASSEMBLY B B D D 3'-7" C C 2' - 6 " A A NOTE: USE TYPE 'C' GRATE, UNLESS OTHERWISE INDICATED. SECTION - BB SECTION - AA SECTION - CC SECTION - DD 1 34"1 34" 1 12"58" 1 12" 2 34" 1 12"1 12" 1 34" 1" 2 34"1 12" FRAME PLAN 3'-0" 2' - 6 " 2'- 4 12" J J K K 3" 9" 9" 3" L M L M SECTION - RR R3" 4 58" 1 58" 1 14" 1"4 34" 34" 5 78"12" 3 12" 1116" 12" 58"1 12" SECTION - MM SECTION - LL SECTION - PP SECTION - NN 2 34"7" 2 18" 1" 1" 1" 1 38"1 38" P P34" 2 18" 7" 1 34" 1"N N SECTION - JJ SECTION - KK HOOD ELEVATION DETAIL #1 SEE DETAIL #1 1116" SLOT FOR 12" BOLT 7"58" 2'-0" 4 58" 58"4" 1 34" 4 34" 10" 10" 4"3" 34" 14" 2'-11 12" R R 1'-2"11"34"34" 1 12" 4" 3'- 78" 3'-0"3 12"3 12" 34"34" 34" 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S C6.4 DE T A I L S 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S C7.0 DE T A I L S 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S C7.1 DE T A I L S 1 05 / 2 3 / 2 3 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S 01-02-2023 Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 D-1387 JDW BAB/KWJ JDW Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 09/13/2024 NC L i c e n s e : P - 1 1 9 9 2 09 / 1 3 / 2 4 RE V I S E D P E R P E R M I T T I N G R E V I E W C O M M E N T S C7.2 DE T A I L S LESTER R & SUZANNE B EDWARDS PID 04110-001-012-000 BLE PROPERTIES LLC PID 04107-006-001-000 NICOLE A JULIAN, ET AL PID 04110-002-022-000 REMAINING PORTION OF ER QUIVER FAMILY LIMITED PARTNERSHIP DB 6447, PG 1326 TRACT ONE PID 04100-003-006-000 STRICKLAND HOLDINGS LLC PID 04100-002-007-000 STRICKLAND HOLDINGS LLC PID 04100-002-017-000 SOUTHEASTERN FREIGHT LINE PID 04100-002-008-000 STRICKLAND HOLDINGS LLC PID 04100-002-007-000 BAY FOODS INC PID 04100-002-006-002 ER QUIVER FAMILY LIMITED PARTNERSHIP, AN ARIZONA LIMITED PARTNERSHIP DEED BOOK 6447, PAGE 1326 TRACT TWO PIN 04100-003-007-000 LEGEND: 0 40 8040 HORIZONTAL SCALE IN FEET 230 HILLIARD AVE, SUITE 1 ASHEVILLE, NORTH CAROLINA 28801 NORTH CAROLINA - LICENSE P-1049 828-575-2118 WWW.ENCOMPASSSERVICES.COM PLLC Providing Solutions REVISIONS: DRAWN BY: AOP CHECKED BY: TJW/TWA FIELD WORK COMPLETED: 09/28/2022 DATE: 10/13/22 DATE: 1/26/23 PROJECT NO. 64149 SCALE: 1" = 40' SHEET 1 OF 1 NO.DATE DESCRIPTION 0 1/26/23 FINAL SUBJECT PROPERTY LINE ADJOINER PROPERTY LINE EASEMENT LINE ROAD RIGHT OF WAY EDGE OF ROAD DITCH GAS PIPELINE OVERHEAD WIRES WATER LINE IRON ROD FOUND 5/8" REBAR WITH CAP IRON PIPE FOUND RIGHT OF WAY MONUMENT FOUND VICINITY MAP (NTS) ALTA/NSPS LAND TITLE SURVEY OF PROPERTY OWNED BY ARK - ROYAL FARMS STORE #551 LOCATED AT 2817A, 2817B, 1820, AND 1824 N 23RD ST., WILMINGTON, NC 28401 CAPE FEAR TOWNSHIP, NEW HANOVER COUNTY, NORTH CAROLINA TREE #SIZE SPECIES 1026 15"CHERRY 1027 13" SWEET GUM 1028 9"MAGNOLIA 1029 23" SWEET GUM 1030 25" SWEET GUM 1031 25"CHESTNUT 1032 28"CHESTNUT 1033 22"CHESTNUT 1034 21" SWEET GUM 1035 28" SWEET GUM 1036 17" SWEET GUM 1037 15" SWEET GUM 1038 17" SWEET GUM 1039 24" SWEET GUM 1040 17" SWEET GUM 1041 19" SWEET GUM 1042 9"OAK 1043 9"MAGNOLIA 1044 17" SWEET GUM 1045 11"MAGNOLIA 1046 18" SWEET GUM 1047 11"OAK 1048 18" SWEET GUM 1049 9"MAGNOLIA 1050 10" SWEET GUM 1051 13" SWEET GUM 1052 15" SWEET GUM 1053 9"OAK 1054 26"OAK TREE #SIZE SPECIES 1000 41"OAK 1001 14" SWEET GUM 1002 16" SWEET GUM 1003 18" SWEET GUM 1004 17" SWEET GUM 1005 15"OAK 1006 12"MULBERRY 1007 16"OAK 1008 28"OAK 1009 17"OAK 1010 11"OAK 1011 26"OAK 1012 35" SWEET GUM 1013 12" SWEET GUM 1014 9"MAGNOLIA 1015 12" SWEET GUM 1016 13" SWEET GUM 1017 12" SWEET GUM 1018 11" SWEET GUM 1019 25" SWEET GUM 1020 8" SWEET GUM 1021 8"OAK 1022 8"OAK 1023 9" SWEET GUM 1024 22" SWEET GUM 1025 25" SWEET GUM GORDO N R D BL U E C A Y R D N 2 3 R D S T CA S T L E H A Y N E R D YORKTO W N D R FOREST L N VIC T O R I A D R COMMITMENT NO: 202211112CA DATED: AUGUST 17, 2022 SCHEDULE B, PART II SPECIAL EXCEPTIONS GENERAL NOTES: _____________________________________________ SITE SCHEDULE B, PART B EXCEPTION LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD L O D L O D L O D L O D L O D L O D L O D L O D L O D LOD LOD LOD LOD LOD LOD LOD LOD L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D LO D L O D L O D L O D LODLODLOD LO D L O D LO D L O D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LOD LOD LOD US H W Y 1 3 3 - C A S T L E H A Y N E R O A D N O R T H 2 3 r d S T R E E T G G G G G G G S S S S S S S SCOCO G G C C C C C W W W W W GV CO SS S S CO FM FM FM FM E GM WM SCOCO UG E UG E UG E UGE UGEUGE UGE 28.02 TC/TA 29.19 TC/TA BC=27.33 BC=27.28 BC=28.00 BC=27.26 BC=27.87 BC=26.85 BC=28.34 TC/TA=27.72 BC=27.26 BC=27.31 BC=27.20 BC=27.37 BC=26.89 BC=27.74 TC/TA=28.10 27.97 TC/TA 28.00 TC/TA TC/TA=28.10 TC/TA=28.30 TC/TA=28.30 29.19 TC/TA BC=28.24 TC=29.41 TC=29.49 TC=29.49 TC=29.42 TC=29.50 BC=27.91 BC=27.88 BC=27.46 BC=27.44 BC=29.03 TC/TA=29.19 TC=28.68 TC=28.65 TC=28.68 TC=28.62 BC=27.31 BC=27.48 BC=27.52 BC=27.55 BC=27.87 STORMWATER MANAGEMENT AREA 95'-4" 40 ' 47.6' 58 . 2 ' 27.7' 46' 42 ' 30' 9' 20 ' 8'8'8' 20 ' 9' R3'R30' 30' 30' R 3 ' R 3 0 ' R2 8 ' R8' R3'R 3 ' R30' R28 ' R 2 2 ' 108' 117'R3 0 ' R 3 2 ' ROYAL FARMS TYPE LEANCON (LEFT) 4,710 S.F. 36 ' R25' R8' 4 4 . 0 4 ' 48' 88.94' TC=28.57 TC=28.47 TC=28.52 TC=28.09 TC=29.31 0+00 1+00 2+00 2+46.31 WM BC=27.71 BC=27.53 BC=27.56 BC=27.53 BC=27.48 TC=29.19 BC/TC=29.08 BC=28.82 BC=27.32 TC/TA=27.71 BC=27.11 FFE=29.60 TC=29.58TC=29.58 CO CO CO CO CO CO CO RD RD RD RD R D RD RD RD RD RDRDRD RDRDRD RD RD 12 5 . 0 2 ' 10 0 . 2 7 ' 23.00 22.50 22.50 23.00 24.10 24.10 23.40 23.40 24.00 23.50 23.50 24.00 24.00 24.00 23.75 23.75 20.70 22.48 20.96 20.95 20.97 12' 10' 1 0 0 ' 9 8 . 1 9 ' 12' 12' 30'30'30' TC=28.62 TC/TA=28.47 21.91 22.15 22.69 20.51 TC/TA=27.19 S S S S S S S S GR I D 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 LBP DML Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 1/2/2023 NC L i c e n s e : P - 1 1 9 9 0 SCALE 1 inch = ft 30' 30 30'15' KNOW WHAT'S BELOW CALL BEFORE YOU DIG! 1-800-632-4949 WWW.NC811.ORG R REFER TO SHEET L-2 FOR LANDSCAPE CALCULATIONS, BUILDING FOUNDATION PLANTING PLAN, PLANTING DETAILS, AND SPECIFICATIONS. ACER RUBRUM 'RED POINTE' 'RED POINT' RED MAPLE BOTANICAL NAME COMMON NAMEKEY QTY.SIZE CONDITION REMARKS 2" - 2 12" CAL. B&B FULL SPECIMEN, HEADED TO 6' HT. SHADE TREES 13 12 QUERCUS PHELLOS WILLOW OAK 8 ULMUS AMERICANA 'PRINCETON' PRINCETON AMERICAN ELM SITE & FOUNDATION PLANT LIST 2" - 2 12" CAL. B&B FULL SPECIMEN, HEADED TO 6' HT. 9 SABAL MINOR DWARF PALMETTO SM 18" - 24" HT. #3 FULL, SPACED 3' O.C. STAGGERED 19VP VIBURNUM PRAGENSE PRAGUE VIBURNUM 2'-3' HT #5 FULL, SPACED 6' O.C. STAGGERED NYSSA SYLVATICA 'TUPELO TOWER' 'TUPELO TOWER' BLACK GUM 2" - 2 12" CAL. B&B FULL SPECIMEN, HEADED TO 6' HT. 13 SHRUBS AND GROUNDCOVER PLANTING NOTES: 1. CONTRACTOR IS TO CALL 811 A MINIMUM OF 72 HOURS PRIOR TO DIGGING. TELEPHONE: 1-800-632-4949. 2. THE LANDSCAPE ARCHITECT IS TO BE NOTIFIED 48 HOURS BEFORE PLANTING BEGINS. THE LOCATION OF ALL PLANT MATERIAL IS TO BE APPROVED IN THE FIELD BY THE LANDSCAPE ARCHITECT. 3. THIS PLAN IS FOR PLANTING ONLY. 4. NO TREE OR SHRUB PLANTING PITS ARE TO BE LEFT OPEN OR UNATTENDED. 5. SHRUBS ARE TO BE GROUPED INTO MULCHED BEDS. THE GRASS IS TO BE KILLED OR REMOVED PRIOR TO MULCHING. PROVIDE A 2" DEEP V-SHAPED DUG EDGE AROUND ALL MULCHED SHRUB BEDS (BEDLINE SHOWN OR IMPLIED). 6. AN IRRIGATION PLAN FOR LAWN AREAS, EXCLUDING THE SWM FACILITY, SHALL BE PREPARED BY A CERTIFIED IRRIGATION CONTRACTOR AND APPROVED BY THE OWNER. 6 - RI 3 - FG 11 - ARC 3 - SM 10 - ARC 10 - ARC 3 - SM 10 - ARC 3 - SM PROP. PRIMARY SIGN (50 SF MAX. AREA / MAX. 20' HT.) 10 - RI 6 - RI 4 - FG 6 - FG 3 - FG ANNUALSANNUALS 9 - FG 6 - VP 3 - FG 9- RI 8' HT. SOLID DUMPSTER ENCLOSURE 13 - VP 68 ABELIA 'ROSE CREEK' 'ROSE CREEK' ABELIA ARC 18" - 24" HT. #3 FULL, SPACED 3' O.C. STAGGERED 34 FOTHERGILLA GARDENII 'MT. AIRY' 'MT. AIRY' FOTHERGILLA FG 18" - 24" HT. #3 FULL, SPACED 4' O.C. STAGGERED 35 RHAPHIOLEPSIS INDICA 'CLARA' 'CLARA' INDIAN HAWTHORNE RI 18" - 24" HT. #3 FULL, SPACED 4' O.C. STAGGERED 15 RU 2" - 2 12" CAL. B&B FULL SPECIMEN, HEADED TO 6' HT. RHAPHIOLEPSIS UMBELLATA 'OLIVIA' 'OLIVIA' INDIAN HAWTHORN 18" - 24" HT. #3 FULL, SPACED 4' O.C. STAGGERED 3 - FG 4 - RI (MIN. 46 REQUIRED PER 5.4.2)46 TYPICAL BEDLINE SODDED LAWN LAWN LAWN LAWN SEEDED DRY DETENTION BASIN (GRASS) REFER TO ENLARGED LANDSCAPE PLAN FOR BUILDING FOUNDATION PLANTINGS (SHEET L-2) 162 LIRIOPE MUSCARI VARIEGATA VARIEGATED LILY TURF ------ 4" POTS SPACED 12" O.C. STAGGERED EX. 22" CHESTNUT TO BE REMOVED TREES NOTED TO BE REMOVED WILL REQUIRE A TREE PERMIT, EXCEPT FOR THE 41" OAK WHICH IS DEAD. SEE ALSO SHEET L-2. SIGHT TRIANGLE SIGHT TRIANGLE SIGHT TRIANGLE SIGHT TRIANGLE MAINTENANCE NOTES: 1. ALL EXISTING VEGETATION THAT IS USED TO COMPLY WITH THE LANDSCAPING REQUIREMENTS, ALL REQUIRED PLANTED LIVING MATERIAL, AND ALL REQUIRED BERMS SHALL BE MAINTAINED BY THE OWNER OF THE PROPERTY ON A CONTINUING BASIS. 2. ANY PLANTED MATERIAL THAT BECOMES DAMAGED OR DISEASED OR DIES SHALL BE REPLACED BY THE OWNER WITHIN 60 DAYS OF THE OCCURRENCE OF SUCH CONDITION. IF THE PLANNING DIRECTOR DETERMINES THERE ARE SEASONAL CONDITIONS THAT WILL NOT PERMIT THE TIMELY REPLACEMENT OF THE VEGETATION (E.G., TOO HOT OR TOO COLD FOR SUCCESSFUL REPLANTING), THE PLANNING DIRECTOR MAY MODIFY THE REQUIREMENT UNTIL A TIME CERTAIN WHEN THE REPLANTING WILL BE SUCCESSFUL. 3. ARTIFICIAL FENCING AND NONLIVING SCREENING BUFFERS SHALL BE MAINTAINED, CLEANED, AND REPAIRED BY THE OWNER OF THE PROPERTY ON A CONTINUING BASIS. SUCH FENCING SHALL BE KEPT FREE OF LITTER AND ADVERTISING. PROP. PRIMARY SIGN (50 SF MAX. AREA / MAX. 20' HT.) L-1 LA N D S C A P E P L A N LAWN LAWN 09-04-2024 LM EX. 41" OAK (DEAD) TO BE REMOVED 3 - FG TYPICAL BEDLINE PROP. SWALE HUMAN & ROHDE, INC. Landscape Architects 512 Virginia Ave. Towson, Maryland 21286 (410) 825-3885 Phone (410) 825-3887 Fax US H W Y 1 3 3 - C A S T L E H A Y N E R O A D N O R T H 2 3 r d S T R E E T G G G G S S S S CO CO G G C C W W W GV CO S S CO FM FM E GM WM SCOCO UG E UGE 28.02 TC/TA 29.19TC/TA BC=27.33 BC=27.28 BC=28.00 BC=27.26 BC=27.87 BC=26.85 BC=28.34 TC/TA=27.72 BC=27.26 BC=27.31 BC=27.20 BC=27.37 BC=26.89 BC=27.74 TC/TA=28.10 27.97TC/TA 28.00TC/TA TC/TA=28.10 TC/TA=28.30 TC/TA=28.30 29.19TC/TA BC=28.24 TC=29.41 TC=29.49TC=29.49 TC=29.42 TC=29.50 BC=27.91 BC=27.88 BC=27.46 BC=27.44 BC=29.03 TC/TA=29.19 TC=28.68 TC=28.65 TC=28.68 TC=28.62 BC=27.31 BC=27.48 BC=27.52 BC=27.55 BC=27.87 STORMWATER MANAGEMENT AREA 95'-4" 40' 47.6' 58 . 2 ' 27.7' 46' 42 ' 30' 9' 20 ' 8'8'8' 20 ' 9' R3'R30' 30' 30' R3 ' R3 0 ' R2 8 ' R8' R3'R3 ' R30' R28' R 2 2 ' 108' 117'R3 0 ' R3 2 ' ROYAL FARMSTYPE LEANCON (LEFT)4,710 S.F. 36 ' R25' R8' 44 . 0 4 ' 48' 88.94' TC=28.57 TC=28.47 TC=28.52 TC=28.09 TC=29.31 0+00 1+00 2+00 2+46. 3 1 WM BC=27.71 BC=27.53 BC=27.56 BC=27.53 BC=27.48 TC=29.19 BC/TC=29.08 BC=28.82 BC=27.32 TC/TA=27.71 BC=27.11 FFE=29.60 TC=29.58TC=29.58 CO CO CO CO CO CO CO RD RD RD RD RDRD RD 125 . 0 2 ' 23.00 22.50 22.50 23.00 24.10 24.10 23.40 23.40 24.00 23.50 23.50 24.00 24.00 24.00 23.75 23.75 20.70 22.48 20.96 20.95 20.97 12' 10' 10 0 ' 9 8 . 1 9 ' 12' 12' 30'30'30' TC=28.62 TC/TA=28.47 21.91 22.15 22.69 20.51 TC/TA=27.19 S S S GRID G G G G G G G G G G G SSSS S S S S S S SS SSS S S S S S S SSS CO CO C C C C C W W W W W W W W W W GV CO SSS S S S S S S SS CO GM CO UGE UG E UG E UG E TC/TATC/TA TC=29.41 TC=29.49TC=29.49 TC=29.42 TC=29.50 20 ' 9' ROYAL FARMS TYPE LEANCON (LEFT) 4,710 S.F. TC=29.31 FFE=29.60 TC=29.58TC=29.58 CO CO CO CO CO CO RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD R D RD RD RD RD RD RD RD RD RD R D TC/TA= S S S S S S S S S S S GR I D 27 5 5 - B C h a r l e s B l v d . Gr e e n v i l l e , N C 2 7 8 5 8 (2 5 2 ) 5 5 8 - 0 8 8 8 ww w . a r k c o n s u l t i n g g r o u p . c o m EN G I N E E R S & P L A N N E R S Drawn By: Checked By: Project Manager: Project Number: Drawing Number: 22075 LBP DML Date: REVISIONS: DE S C R I P T I O N DA T E # Ne w H a n o v e r C o u n t y , N o r t h C a r o l i n a IN T E R S E C T I O N O F U S H W Y 1 3 3 & N 2 3 r d S T R E E T RO Y A L F A R M S # 5 5 1 1/2/2023 NC L i c e n s e : P - 1 1 9 9 PLANT IDENTIFICATION: All plants shall be identified in accordance with the latest edition of Hortus Third, by "The Staff of the Hortorim". LIST OF PLANT MATERIALS: The contractor will verify plant quantities prior to bidding and any discrepancies shall be brought to the attention of the Landscape Architect. The Contractor shall furnish and plant all plants required to complete the work as shown on the drawings. Substitutions shall not be made without the written approval of the Landscape Architect. This contract will be based on the bidder having verified, prior to bidding, the availability of the required plant materials as specified on the Plant List. PLANT QUANTITY: All shrubs shall be dense, heavy to the ground, and well grown, showing evidence of having been sheared regularly, and sound, free of plant disease or insect eggs, and shall have a healthy, normal root system. Plants shall be nursery grown. Plants shall not be pruned prior to delivery. The shape of the plant shall in general conform to its natural growth proportions unless otherwise specified. All plants including container grown shall conform to American Standard for Nursery Stock (ANSI z60.1, latest edition), and shall have a well-shaped, heavy branch structure for the species. Evergreen trees are to have an internode no greater than 24" and shall be uniformly well-shaped. All plant sizes shall average at least the middle of the range given in the plant list. PLANT SPACING: Plant spacing is to scale on the plan or as shown on the plant list. SOIL MIX: Soil mix will be 23 existing soil and 13 LEAFGRO or equal organic material, thoroughly mixed and homogenized. BALL SIZE: The ball size shall conform to the American Association of Nurserymen's publication entitled American Standard For Nursery Stock, ANSI z60.1, latest edition. EXCAVATION: Holes for all plants shall be 18" larger in diameter than size of ball or container and shall have vertical sides. Hedges shall be planted in a trench 12" wider than ball diameter. Beds for mass planting shall be entirely rototilled to a depth of 8" and shall be 18" beyond the average outside edge of plant balls. A 2" layer of organic material ( i.e., LEAFGRO) will be incorporated into plant beds by tilling again. PLANTING: Backfilling shall be done with soil mix, reasonably free of stones, subsoil, clay, lumps, stumps, roots, weeds, Bermuda grass, litter, toxic substances, or any other material which may be harmful to plant growth or hinder grading, planting, or maintenance operations. Should any unforeseen or unsuitable planting conditions arise, such as faulty soil drainage or chemical residues, they should be called to the attention of the Landscape Architect and Owner for adjustments before planting. The plant shall be set plumb and straight and shall be staked at the time of planting. Backfill shall be well worked about the roots and settled by watering. Plants will be planted higher than surrounding grade. Shrubs will be 1" higher and trees will be 3" higher. Remove rope from around tree trunks and lay back burlap from top of all B&B material. Nylon or vinyl rope and/or burlap will be completely removed from all plant material prior to planting. TRANSPLANTING TREES BY TREE MACHINES: Trees shall be moved by machines that provide a minimum of 9" per 1" of tree caliper. Holes are to be dug by the same size machine as the one transporting the plant. The plant material shall be transplanted in approximately the same growing condition as it is presently growing, in terms of soil type and moisture content. Fertilize and guy as described in these plans and specifications. CULTIVATION: All trenches and shrub beds shall be cultivated, edged and mulched to a depth of 3" with shredded hardwood. The area around isolated plants shall be mulched to at least 6" greater diameter than that of the hole. Plant beds adjacent to buildings shall be mulched to the building wall. MAINTENANCE: The Contractor shall be responsible during the contract and up to the time of acceptance for keeping the planting and work incidental thereto in good condition, by replanting, plant replacement, watering, weeding, cultivating, pruning and spraying, restaking and cleaning up and by performing all other necessary operations of care for promotion of good plant growth so that all work is in satisfactory condition at time of acceptance, at no additional cost to the Owner. FERTILIZER: The Contractor shall apply granular fertilizer to the soil mix with 10-6-4 analysis, 50% organic, at the following rates: Trees @ 2-3 lbs. per caliper inch; Shrub Beds @ 3-5 lbs per 100 sq.ft.; and Groundcover Beds @ 2-3 lbs. per 100 sq.ft. GROUNDCOVER: All areas of groundcover shall be rototilled to a depth of 6". Apply 2" of organic material and rototill until thoroughly mixed. Apply fertilizer as stated above. GUARANTEE AND REPLACEMENT: All material shall be unconditionally guaranteed for one (1) year. The Contractor is responsible for watering but not for losses or damage caused by mechanical injury or vandalism. SPECIFICATIONS FOR PLANTING EXCAVATION: Holes for all plants shall be 18" larger in diameter than size of ball or container and shall have vertical sides. Hedges shall be planted in a trench 12" wider than ball diameter. Beds for mass planting shall be entirely rototilled to a depth of 8" and shall be 18" beyond the average outside edge of plant balls. A 2" layer of organic material ( i.e., LEAFGRO) will be incorporated into plant beds by tilling again. PLANTING: Backfilling shall be done with soil mix, reasonably free of stones, subsoil, clay, lumps, stumps, roots, weeds, Bermuda grass, litter, toxic substances, or any other material which may be harmful to plant growth or hinder grading, planting, or maintenance operations. Should any unforeseen or unsuitable planting conditions arise, such as faulty soil drainage or chemical residues, they should be called to the attention of the Landscape Architect and Owner for adjustments before planting. The plant shall be set plumb and straight and shall be staked at the time of planting. Backfill shall be well worked about the roots and settled by watering. Plants will be planted higher than surrounding grade. Shrubs will be 1" higher and trees will be 3" higher. Remove rope from around tree trunks and lay back burlap from top of all B&B material. Nylon or vinyl rope and/or burlap will be completely removed from all plant material prior to planting. TRANSPLANTING TREES BY TREE MACHINES: Trees shall be moved by machines that provide a minimum of 9" per 1" of tree caliper. Holes are to be dug by the same size machine as the one transporting the plant. The plant material shall be transplanted in approximately the same growing condition as it is presently growing, in terms of soil type and moisture content. Fertilize and guy as described in these plans and specifications. CULTIVATION: All trenches and shrub beds shall be cultivated, edged and mulched to a depth of 3" with shredded hardwood. The area around isolated plants shall be mulched to at least 6" greater diameter than that of the hole. Plant beds adjacent to buildings shall be mulched to the building wall. KNOW WHAT'S BELOW CALL BEFORE YOU DIG! 1-800-632-4949 WWW.NC811.ORG R 2'- 0 " 4'- 0 " PLANTING DETAIL FOR DECIDUOUS AND EVERGREEN TREES (1" - 4" CALIPER) 6" 12" TWO (2) PIECES OF REINFORCED RUBBER HOSE 6" EXPOSED SOIL AT ROOT FLARE. NO MULCH. FIRST LATERAL ROOT FLUSH WITH FINISHED GRADE MULCH RING TO BE EDGED TO A MINIMUM 3" DEPTH 3" MULCH NOTE: STAKES AND WIRE ARE TO BE REMOVED AT THE COMPLETION OF ONE (1) FULL GROWING SEASON. FINISHED GRADE UNDISTURBED SOIL SOIL MIX SELECTIVELY PRUNE CROSSING, BROKEN, OR DAMAGED LIMBS. RETAIN NATURAL FORM OF TREE. DO NOT PRUNE CENTRAL LEADER. HEIGHT OF BRANCHING TO BE A MINIMUM OF 6' #12 GALVANIZED WIRE GUYS (TWISTED) TWO (2) 6' HT. 2"X2" OAK STAKES, NOTCHED TO HOLD WIRE REMOVE ANY COVERING AND TYING FROM TOP OF ROOT BALL AND TRUNK SCALE: NONE 12" 6" 6" PLANTING DETAIL FOR EVERGREEN & DECIDUOUS SHRUBS SCALE: NONE THIN DECIDUOUS 13 OFINITIAL BRANCHING, RETAINING NATURAL FORM REMOVE COVERING FROM TOP 13 OF ROOT BALL FIRST LATERAL ROOT FLUSH WITH FINISHED GRADE 3" MULCH 3" SOIL WELL FINISHED GRADE UNDISTURBED SOIL PLANTING SOIL REQUIRED LANDSCAPING: 5.4.2 GENERAL STANDARDS B.MIN. 15 TREES (MIN. 2" CAL.) / ACRE OF DISTURBANCE: 3.05 AC. X 15 = 46 TREES REQUIRED 5.4.4 SCREENING C.2 SCREEN DUMPSTER FROM PUBLIC R/W OR ADJACENT PROPERTY / MIN. 8' HT. 5.4.5 PARKING LOTS B. PERIMETERS ABUTTING ANOTHER PARKING LOT OR LAND IN RESIDENTIAL ZONE C INTERIORS: 8% OF TOTAL PARKING/VEHICULAR AREAS: 34,390 SF X 0.08 = 2,751 SF REQUIRED ISLANDS: MIN. 12' WIDE / NO MORE THAN 120' APART 1 TREE / 144 SF OF INTERIOR AREA: 3,200 SF PROVIDED / 144 = 22 TREES REQUIRED MIN. 75% OF TREES MUST BE SHADE TREES D.MIN. 3' HT. PLANTING/BERM FOR PARKING WITHIN 50' OF R/W AND NO OTHER BUFFER REQUIREMENTS 5.4.6 STREET YARD STANDARDS B.B-1 ZONE: 18 SF FOR EVERY LINEAR FOOT OF STREET FRONTAGE MIN. 9' WIDE / MAX. 27' WIDE C.1 SHADE TREE (OR 3 UNDERSTORY TREES) + 6 SHRUBS / 600 SF OF STREET YARD E.PRIMARY STREET FRONTAGE: 100% OF REQUIREMENTS * US HWY 133 (CASTLE HAYNE ROAD): 401 LF X 18' = 7,218 SF / 600 = 12 TREES + 72 SHRUBS SECONDARY STREET FRONTAGE: 50% OF REQUIREMENTS * NORTH 23RD STREET: 474 LF X 9' (50% OF18') = 4,266 / 600 = 7 TREES + 42 SHRUBS 5.4.7 FOUNDATION PLANTINGS A.REQUIRED WHERE FACADE IS ADJACENT TO PARKING OR DRIVE AISLES B.12% OF FLOOR AREA: 4,710 SF X .0.12 = 565 SF LANDSCAPE CALCULATIONS PROPOSED LANDSCAPING: 5.4.2 GENERAL STANDARDS 46 TOTAL TREES PROVIDED 5.4.4 SCREENING C.2 DUMPSTER ENCLOSURE 8' HT. SOLID SCREEN + SHRUBS 5.4.5 PARKING LOTS B. DOES NOT APPLY C INTERIORS: 3,200 SF INTERIOR LANDSCAPED AREA PROVIDED = 9.3% ISLANDS: MIN. 12' WIDE / NO MORE THAN 120' APART 22 TREES PROVIDED 100% SHADE TREES PROVIDED D.SHRUBS PROVIDED AS PART OF STREET YARD PLANTING 5.4.6 STREET YARD STANDARDS B.B-1 ZONE: 18 SF FOR EVERY LINEAR FOOT OF STREET FRONTAGE MIN. 9' WIDE / MAX. 27' WIDE C.1 SHADE TREE (OR 3 UNDERSTORY TREES) + 6 SHRUBS / 600 SF OF STREET YARD E.PRIMARY STREET FRONTAGE: 100% OF REQUIREMENTS * US HWY 133 (CASTLE HAYNE ROAD): 18' WIDE / 7,150 SF PROVIDED (12) 2" CAL. TREES + 72 SHRUBS PROVIDED SECONDARY STREET FRONTAGE: 50% OF REQUIREMENTS * NORTH 23RD STREET: 9' WIDE / 4,256 SF PROVIDED (7) 2" CAL. TREES + 42 SHRUBS PROVIDED 5.4.7 FOUNDATION PLANTINGS A.REQUIRED WHERE FACADE IS ADJACENT TO PARKING OR DRIVE AISLES B.855 SF PROVIDED (18%) LANDSCAPE CALCULATIONS AND TREE REMOVAL PLAN SCALE: 1" = 50' STREET YARD AREA 11,406 SF PARKING LOT AREA 34,390 SF INTERIOR AREA 3,200 SF BUILDING FOUNDATION AREA 855 SF LEGEND PRIMARY FRONTAGE (18' W. STREET YARD) SECONDARY FRONTAGE (9' W. STREET YARD) 4,710 SF BUILDING FOUNDATION PLANTING PLAN SCALE: 1" = 10' B-1 ZONE B-1 ZONE NOTE: TREE MITIGATION FEE TO BE PAID IN LIEU OF PLANTING. (5.3.7) EX. 41" OAK (DEAD) TO BE REMOVED (SEE NOTE 2 BELOW) EX. 26" OAK TO BE REMOVED (TREE PERMIT) EX. 28" OAK TO BE REMOVED (TREE PERMIT) EX. 25" OAK TO BE REMOVED (TREE PERMIT) EX. 28" OAK TO BE REMOVED (TREE PERMIT) EX. 22" CHESTNUT TO BE REMOVED (TREE PERMIT) TREE REMOVAL NOTES: 1.REFER TO THE CHART AT RIGHT SIDE OF THIS SHEET FOR TREE REMOVAL/MITIGATION CALCULATIONS. 2.A TREE PERMIT WILL BE OBTAINED FOR THE TREES NOTED TO BE REMOVED, WITH THE EXCEPTION OF THE EXISTING 41" OAK WHICH IS DEAD. SI D E W A L K OUTDOOR SEATING AREA OUTDOOR SEATING AREA SIDEWALK 8 - RU 15 - ARC 122 - LM 40 - LM 12 - ARC 7 - RU SIDEWALK TREES REQUIRED: PARKING LOT INTERIOR: 22 PRIMARY STREET YARD: 12 + 72 SHRUBS SECONDARY STREET YARD: 7 + 42 SHRUBS 41 +114 SHRUBS TREES PROVIDED: PARKING LOT INTERIOR: 22 + 5 = 27 PRIMARY STREET YARD: 12 + 72 SHRUBS SECONDARY STREET YARD: 7 + 42 SHRUBS 46 +114 SHRUBS 46 TREES PROVIDED - MEETS THE REQUIREMENT UNDER 5.4.2. BEDLINE BEDLINE L-2 LA N D S C A P E P L A N 09-04-2024 NOTE: REFER TO SHEET L-1 FOR PLANT LIST. HUMAN & ROHDE, INC. Landscape Architects 512 Virginia Ave. Towson, Maryland 21286 (410) 825-3885 Phone (410) 825-3887 Fax