Loading...
HomeMy WebLinkAbout202304700-SITE-C3D21-NC-MEE-C-001IV E Y B R I D G E L A N E (5 5 ' P U B L I C R I G H T - O F - W A Y ) N. C . H I G H W A Y 1 3 2 - S . C O L L E G E R O A D WHISKEY BRANCH DRIVE CO N D O R R U N ELECTRI C A V E N U E W H I S K E Y B R A N C H D R I V E W H I S K E Y B R A N C H D R I V E 20 0 ' P U B L I C R . O . W . PHASE 2 204,699 SQ.FT. ± 5.10 AC. ± PHASE 1 514,373 SQ.FT. ± 14.22 AC. ± N. C . H I G H W A Y 1 3 2 - S . C O L L E G E R O A D WHISKEY BRANCH DRIVE CO N D O R R U N ELECTRI C A V E N U E W H I S K E Y B R A N C H D R I V E W H I S K E Y B R A N C H D R I V E 20 0 ' P U B L I C R . O . W . 50' PRIVATE R.O.W. PUBLIC UTILITY EASEMENT 50' P R I V A T E R . O . W . P U B L I C U T I L I T Y E A S E M E N T SE A F O R T H D R I V E 50 ' P R I V A T E R . O . W . PU B L I C U T I L I T Y E A S E M E N T PHASE 1 514,373 SQ.FT. ± 14.22 AC. ± NEXUS 0 S COLLEGE ROAD BRANCH WILMINGTON, NC NEW HANOVER COUNTY WHISKEY 12/6/2023 2023047.00 C-001 1" = 60' North Carolina 309 South Governors Avenue Dover, DE 19904 302.734.7950 312 West Main Street, Suite 300 Salisbury, MD 21801 410.546.9100 Maryland www.beckermorgan.com Delaware A E R N C G H I I N T E E E C R T I U N G R E 910.341.7600 Wilmington, NC 28403 3333 Jaeckle Drive, Suite 120 The Tower at STAR Campus 100 Discovery Boulevard, Suite 102 Newark, DE 19713 302.369.3700 .PDF MEE M.D.S. COVER SHEET . . . ... . \\bmgilm01\Cad\AutoCADCivil\Projects\2023\2023047\DWG\202304700-SITE-C3D21-NC-MEE.dwg, Dec 06, 2023 - 11:31am 2023-12-06 DRAWN BY: DATE: PROJECT NO.: COPYRIGHT 2023 MARK DATE DESCRIPTION ISSUE BLOCK PROJECT TITLE SHEET TITLE SCALE: SHEET PROJ. MGR.: C-001LAYER STATE: 0 SCALE: 1" = 100' 50 100 200 N . VICINITY MAP SCALE 1" = 500' SITE N W H I S K E Y B R A N C H D R . S C O L L E G E R O A D ELECT R I C A V E . SHEET INDEX COVER SHEET UTILITIES PLAN LANDSCAPING PLAN C-001 SITE PLAN 3333 JAECKLE DRIVE, SUITE 120 WILMINGTON, NC 28403 PHONE: 910-341-7600 BECKER MORGAN GROUP INC. SITE DATA 1. 4. 5. 6. PROPOSED: 7. 8. 9. 10. 12. 16.NAIL SET ELEV. 28.66' 17. OWNER OF RECORD: ENGINEER: TAX MAP NUMBER:R07100-004-426-000 ZONING CLASSIFICATION: EXISTING: PD PD PARCEL AREA:± 64.28 ACRES PRESENT USE:VACANT/PARTIALLY CLEARED PROPOSED USE:MULTI-FAMILY RESIDENTIAL SETBACKS:FRONT/REAR: 10' SOURCE OF WATER & SEWER:CAPE FEAR PUBLIC UTILITY AUTHORITY SURVEY BENCHMARK: DATUM: NAVD 88 ± 184,757 S.F.PROPOSED BUILDING GFA: 13.IMPERVIOUS COVERAGE:PROPOSED: 449,528 S.F. (10.32 ACRES) 14.TOTAL: 542 PARKING PROVIDED: 15. FEMA FLOOD ZONE:BASED ON FEMA FIRM PANEL 3720313500K, DATED AUGUST 28, 2018, THIS SITE AREA IS LOCATED IN FLOOD ZONE X UNSHADED AREA OF MINIMAL FLOOD HAZARD 2.PREMISES ADDRESS:0 S COLLEGE ROAD WILMINGTON, NC 28409 DRY POND PARTNERS LLC P.O. BOX 3649 WILMINGTON, NC 28406 BLUE RIDGE DEVELOPMENT SERVICES c/o HUNTER OGLESBY 5826 SAMET DRIVE SUITE 105 HIGH POINT, NC 27265 3.OWNER/DEVELOPER: PHONE: 336-706-9002 NEXUS WHISKEY BRANCH SUBDIVISION WILMINGTON NEW HANOVER COUNTY, NC 2023047.00 C-201 C-301 L-001-L-201 CO N D O R R U N PHASING PLANC-002 CONCRETE CURB & GUTTER CONCRETE SIDEWALK, SLAB / PAVING IMPERVIOUS SURFACED ROAD, DRIVE INDIVIDUAL TREE OR BUSH STRUCTURE (CONCRETE, WOOD, DRAINAGE DITCH OR SWALE WETLAND BOUNDARY LINE ELEVATION SPOT SHOT PROPERTY OR RIGHT-OF-WAY LINE LIGHT POLE CENTERLINE BENCH MARK METAL, ETC.) CONTOUR OR PARKING LOT WIRE FENCE 49 EVERGREEN DECIDUOUS N/A N/A X X X CHAINLINK FENCE STOCKADE FENCE 43.55 X X X 55 25.15 B.C.25.00 T.C.25.50 V V V N/A ITEM WATER MAIN & SIZE PROPOSED LEGEND EXISTING EX. 10" F.M. EX. 10"S EX. 10" W U.E. U.T. EX. 2" G 10" S 12" F.M. 12" W U.E. U.T. 2" G SANITARY GRAVITY SEWER LINE (S) SIZE & FLOW DIRECTION C-1-Notes-Legend-Portrait SANITARY SEWER CLEANOUT (C.O.) WATER VALVE (W.V.), BACKFLOW PREVENTER, WATER METER (W.M.) FIRE HYDRANT (F.H.) SANITARY SEWER MANHOLE (S.S.M.H.) STORM DRAIN MANHOLE (S.D.M.H.) CATCH BASIN (C.B.) STORM DRAIN LINE (CMP, RCP, HDPE) SANITARY SEWER FORCE MAIN (F.M.) SIZE & FLOW DIRECTION UNDERGROUND ELECTRIC (U.E.) UNDERGROUND TELEPHONE (U.T.) UNDERGROUND GAS MAIN (G) UTILITY POLE W/ OVERHEAD SERVICE (TELEPHONE (O.T.), ELECTRIC (O.E.) F.H. W.V.W.M.W.M.W.V. F.H. GENERAL NOTES 1.NO WETLANDS PRESENT IN DEVELOPMENT AREA . 2.ALL CONSTRUCTION IS TO CONFORM TO NEW HANOVER COUNTY STANDARDS AND APPLICABLE STATE AND LOCAL CODES. 3.CONTRACTOR TO COORDINATE ANY REQUIRED TRAFFIC CONTROL WITH THE CITY OF WILMINGTON AND/OR NCDOT. 4.CARE SHALL BE TAKEN DURING FINAL GRADING TO ENSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS AND TO RECEIVING STRUCTURES. ROOF DRAIN DOWNSPOUTS TO BE CONNECTED TO STORM DRAINAGE STUBOUTS OR DIRECTED TO STREET AND/OR PARKING AREAS. 5.CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ANY RELOCATIONS, REALIGNMENTS, DISCONNECTIONS, OR CONNECTIONS OF EXISTING UTILITIES WITH APPLICABLE AUTHORITIES. 6.CLEARING AND GRUBBING OF SITE TO INCLUDE REMOVAL OF EXISTING CURB, ASPHALT, INLETS, AND ANY OTHER STRUCTURES INCLUDING TREES, STUMPS AND DEBRIS EXISTING ON SITE. TREES NOT REQUIRED TO BE CLEARED FOR CONSTRUCTION SHALL REMAIN UNLESS OTHERWISE DIRECTED. 7.INFORMATION REGARDING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXACT ELEVATIONS AND LOCATIONS OF ALL EXISTING UTILITIES AT ALL CROSSINGS PRIOR TO COMMENCING TRENCH EXCAVATION. IF ACTUAL CLEARANCES ARE LESS THAN INDICATED ON PLAN, THE CONTRACTOR SHALL CONTACT THE DESIGN ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. ANY CONDITION DISCOVERED OR EXISTING THAT WOULD NECESSITATE A MODIFICATION OF THESE PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. 8.NO CONSTRUCTION IS TO BEGIN BEFORE LOCATION OF EXISTING UTILITIES HAS BEEN DETERMINED. CALL "NC ONE-CALL" AT LEAST 72 HOURS PRIOR TO THE START OF CONSTRUCTION. 9.THE CONTRACTOR IS RESPONSIBLE FOR CONTROLLING DUST AND EROSION CREATED DURING CONSTRUCTION AT HIS OR HER EXPENSE. PARKING AREAS SHALL BE WATERED TO CONTROL DUST WHEN ORDERED BY THE ENGINEER. 10.CONTRACTOR TO ENSURE THAT PAVEMENT IS PLACED SO AS TO DRAIN POSITIVELY TO THE STREET CATCH BASINS. ALL FUTURE ROOF DRAIN DOWNSPOUTS ARE TO BE DIRECTED TO THE STORM DRAINAGE STUBOUTS. 11.CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS PRIOR TO THE START OF CONSTRUCTION. 12.CONTRACTOR AND BUILDER ARE RESPONSIBLE FOR COORDINATING FINISHED FLOOR ELEVATIONS OF ALL BUILDINGS WITH THE OWNER. 13.MINIMUM SEPARATION OF UTILITIES SHALL BE MAINTAINED AS FOLLOWS: 13.1.HORIZONTAL SEPARATION OF TEN (10) FEET BETWEEN SANITARY SEWER AND WATER MAINS AND STORM SEWER. 13.2.WHERE VERTICAL CLEARANCE IS LESS THAN TWENTY-FOUR (24) INCHES BETWEEN SANITARY SEWER AND STORM DRAIN, SANITARY SEWER SHALL BE DUCTILE IRON PIPE FOR A MINIMUM OF 10 FEET EITHER SIDE OF CROSSING. 13.3.WHERE VERTICAL CLEARANCE IS LESS THAN TWELVE (12) INCHES BETWEEN SANITARY SEWER AND STORM DRAIN, SANITARY SEWER SHALL BE DUCTILE IRON PIPE FOR A MINIMUM OF 10 FEET EITHER SIDE OF THE CROSSING, AND BRIDGING SHALL BE INSTALLED PER APPLICABLE UTILITY AUTHORITY'S DETAILS. 13.4.IN NO CASE SHALL THERE BE LESS THAN EIGHTEEN (18) INCHES OF SEPARATION BETWEEN OUTSIDE OF WATER MAIN AND OUTSIDE OF SEWER OR STORM SEWER. 13.5.MINIMUM COVER OF THIRTY-SIX (36) INCHES SHALL BE PROVIDED FOR ALL BURIED WATER MAINS AND SANITARY SEWER MAINS. 14.ALL SANITARY SEWER MAINS TO BE 8 INCHES UNLESS OTHERWISE INDICATED. 15.ALL WATER MAINS TO BE 8 INCHES UNLESS OTHERWISE INDICATED. 16.TWO VALVES ARE REQUIRED AT "T" INTERSECTIONS AND ONE VALVE ON THE WATER LINE TO FIRE HYDRANTS. 17.A BLOW-OFF VALVE IS REQUIRED AT THE TERMINUS OF ALL "DEAD END" WATER LINES. SITE SIGNAGE:SUBJECT TO SECTION 5.6 OF THE UDO SIDE: 20' OPEN SPACE (PHASE 1):PROPOSED: 4.43 ACRES OPEN SPACE (PHASE 2):PROPOSED: 1.59 ACRES TOTAL: 61 TOTAL: 481 PHASE 1: PHASE 2: 11.MAX BUILDING HEIGHT:56 FT.