Loading...
HomeMy WebLinkAboutDriveway Permit STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION ROY COOPER J.ERIC BOYETTE GOVERNOR SECRETARY Mailing Address: NC DEPARTMENT OF TRANSPORTATION DIVISION OF HIGHWAYS 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 04-11-03 COURIER Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 December 20, 2023 Bryant Ligon FDCC, LLC 1208 Main Street Summerville, SC 29483 Subject: Permit D033-065-23-00017 for the Townes at Park Place is located on Carolina Beach Road (US 421 in New Hanover County. Dear Sir: Your request for the subject development access has been approved per the attached plans dated August 16, 2023 (sealed by Timothy G. Clinkscales, PE with Paramounte Engineering, Inc.), are subject to the following conditions and the attached Driveway Permits Standard Conditions. •This is for a driveway connection to Carolina Beach Road (US 421) and the roadway improvements for the extension of the right turn lane. •No obstructions shall be allowed in the location of the right of way (10 ft X 70 ft) sight triangles along the right of way line including the sight distance at the sites accesses along the roadway. The applicant/HOA shall conduct a routine vegetations removal as part of maintenance operation to provide a safe line of sight. •A $107,000.00 performance and indemnity bond from Heath Grading and Utility, Inc. has been posted with the North Carolina Department of Transportation and is hereby obligated to cover roadway improvements under this driveway permit. •The bond will be held for a minimum of one year from the initial inspection and acceptance date of the roadway work within the NCDOT right-of-way. •This permit does not provide approval for any construction outside of NCDOT right-of-way. Any construction planned or proposed outside NCDOT right-of-way shall require the developer to obtain concurrence and/or right-of-way from subject property owner and/or local government. •This driveway is considered a commercial type of driveway and it shall be maintained by the property owner/developer/HOA/POA per NCDOT policy. •The terms and conditions of this permit shall be incorporated into any lease or sales agreement and all lots (outparcels), including all remaining undeveloped tracts within the subject development, shall be served internally. •The developer is responsible for obtaining all permits and approvals necessary for the development of this project prior to commencement of any construction activities within the NCDOT right-of-way. •This driveway permit does not include any utility connections or approvals within the Right- of-Way. Such approvals are managed through a separate Encroachment Agreement. •All improvements, i.e., roadway pavement widening, traffic control, pavement markings, etc., shall be constructed following the 2018 NCDOT Standard Specifications for Roads and Structures and the 2018 NCDOT Roadway Standard Drawings. •Time Restriction – Peak Hours Restricted: No lane closures shall be allowed from 6:00am to 9:00am and from 3:00pm to 7:00pm and NO weekend lane closures. (HOURS SUBJECT TO CHANGE DUE TO TRAFFIC CONDITIONS – NIGHTTIME OPERATIONS WILL BE REQUIRED WHEN WARRANTED) due the project is located within the vicinity of the schools. •No lane closures shall be allowed on State holidays and local events. •Upon completion of construction, a certification memo that has been signed and sealed as proper under G.S. 89C-16 by a North Carolina Professional Engineer or Professional Land Surveyor, shall be submitted to the District Engineer prior to opening the access connection for public use. Supporting documents shall be attached certifying that improvements meet the approved plan and NCDOT standards. All documentation must be dated and initialed by the contractor. Verification will include QMS forms (QMS-MV1 and QMS-MV2), inspection reports, testing reports, or any supporting documentation and calculations. Verification will cover, but is not limited to sub-grade, pavement structure, drainage, and traffic control items. •A pre-construction conference is required prior to beginning construction. To schedule, contact an engineering technician at the District Office at (910) 398-9100. Sincerely, Jon Roan, Deputy Assistant District Engineer for Benjamin T. Hughes, P.E. District Engineer BTH/Jr ec: Kathy Stephens, New Hanover County Maintenance Engineer, NCDOT Stonewall Mathis, P.E., Division Traffic Engineer, NCDOT Robert Farrell, Senior Current Planner, New Hanover County APPLICATION IDENTIFICATION N.C. DEPARTMENT OF TRANSPORTATION Driveway Permit No. Date of Application STREET AND DRIVEWAY ACCESS County: New Hanover PERMIT APPLICATION Development Name: Townes at Park Place LOCATION OF PROPERTY: Route/Road: Antoinette Drive (SR 1247) Exact Distance 0.27 Miles N S E W Feet From the Intersection of Route No. US Hwy 421 and Route No. SR 1247 Toward Normandy Dr. Property Will Be Used For: Residential /Subdivision Commercial Educational Facilities TND Emergency Services Other Property: is is not within Wilmington City Zoning Area. AGREEMENT  I, the undersigned property owner, request access and permission to construct driveway(s) or street(s) on public right- of-way at the above location.  I agree to construct and maintain driveway(s) or street entrance(s) in absolute conformance with the current “Policy on Street and Driveway Access to North Carolina Highways” as adopted by the North Carolina Department of Transportation.  I agree that no signs or objects will be placed on or over the public right-of-way other than those approved by NCDOT.  I agree that the driveway(s) or street(s) will be constructed as shown on the attached plans.  I agree that that driveway(s) or street(s) as used in this agreement include any approach tapers, storage lanes or speed change lanes as deemed necessary.  I agree that if any future improvements to the roadway become necessary, the portion of driveway(s) or street(s) located on public right-of-way will be considered the property of the North Carolina Department of Transportation, and I will not be entitled to reimbursement or have any claim for present expenditures for driveway or street construction.  I agree that this permit becomes void if construction of driveway(s) or street(s) is not completed within the time specified by the “Policy on Street and Driveway Access to North Carolina Highways”.  I agree to pay a $50 construction inspection fee. Make checks payable to NCDOT. This fee will be reimbursed if application is denied.  I agree to construct and maintain the driveway(s) or street(s) in a safe manner so as not to interfere with or endanger the public travel.  I agree to provide during and following construction proper signs, signal lights, flaggers and other warning devices for the protection of traffic in conformance with the current “Manual on Uniform Traffic Control Devices for Streets and Highways” and Amendments or Supplements thereto. Information as to the above rules and regulations may be obtained from the District Engineer.  I agree to indemnify and save harmless the North Carolina Department of Transportation from all damages and claims for damage that may arise by reason of this construction.  I agree that the North Carolina Department of Transportation will assume no responsibility for any damages that may be caused to such facilities, within the highway right-of-way limits, in carrying out its construction.  I agree to provide a Performance and Indemnity Bond in the amount specified by the Division of Highways for any construction proposed on the State Highway system.  The granting of this permit is subject to the regulatory powers of the NC Department of Transportation as provided by law and as set forth in the N.C. Policy on Driveways and shall not be construed as a contract access point.  I agree that the entire cost of constructing and maintaining an approved private street or driveway access connection and conditions of this permit will be borne by the property owner, the applicant, and their grantees, successors, and assignees. I AGREE TO NOTIFY THE DISTRICT ENGINEER WHEN THE PROPOSED WORK BEGINS AND WHEN IT IS COMPLETED. 2004-07 NOTE: Submit Four Copies of Application to Local District Engineer, N.C. Department of Transportation TEB 65-04rev. 61-03419 for Benjamin T. Hughes, P.E. 12/20/2023 Division 3, District 3 Updated 07/26/2023. The Standard Conditions in this document apply to this and all driveway permits issued by District 3. Driveway Permit Standard Conditions District Office Contact Information: 5911 Oleander Drive, Suite 101 Wilmington, NC 28403 (910) 398-9100 SC1 A Pre-Construction meeting must be held with the District Office within 90 days of approval. All locates Shall be completed prior to the scheduling of meeting. SC2 The Permittee shall follow any and all revisions shown in RED on attached plan(s). SC3 The driveway permit along with all terms and agreements shall be incorporated into any lease or sales agreement. SC4 If the approved permit encroaches within the limits of an active construction project the Permittee will be required to coordinate with the NCDOT contractor as well as secure a hold harmless agreement prior to commencing work. If the approved permit encroaches within the limits of project in preconstruction, the Permittee will be required to coordinate with the Department’s Project Development Unit to ensure no conflicts are created with the installation. SC5 A Performance and Indemnity Bond posted with the North Carolina Department of Transportation is hereby obligated to cover work under this driveway permit. This bond is only for work within NCDOT Right of Way. SC6 An Initial Construction Inspection is required after the completion of the work. An Initial Inspection Report will be issued upon satisfactory completion of the work and begins the one-year warranty period. Contact the District Office to schedule an inspection by calling 910-398-9100 or email at Div3Dist3@ncdot.gov. SC7 All bonds will be held for a minimum of one year from the time of the Initial Construction Inspection Acceptance. At the end of that time period, the bond may be released at the request of the applicant pending Final Inspection Acceptance. SC8 A Final inspection is required after one year and prior to release of the bond. Contact the District Office three months prior to the end of the one-year bonding period for final inspection and creation of a list of deficiencies; this should provide enough time for corrective action prior to the end of one year. A Final Inspection Acceptance will be issued once the work has been completed and any deficiencies addressed. SC9 All flagging operations within NCDOT right-of-way require qualified and trained Work Zone Flaggers. Qualified and trained Work Zone Traffic Control Supervisors will be required on significant projects. Training for this certification is provided by NCDOT approved training sources and by private entities that have been pre-approved. For more information, visit https://connect.ncdot.gov/projects/WZTC/Pages/Training.aspx or contact Steve Kite, PE with the NCDOT Work Zone Traffic Control Unit at (919) 814-4937, or skite@ncdot.gov. SC10 No lane closures shall be allowed on State Holidays (day of, day before, and day after) or during Local events. SC11 No lane closures or impediment to traffic shall be allowed on weekends without prior written approval from the District Engineer. SC12 One lane must always be open to traffic; only one lane closure will be allowed in each direction. Ingress and egress shall be maintained to all businesses and dwellings affected by the project. Special attention shall be paid to Police and Fire Stations, fire hydrants and Hospitals. SC13 All roadway signs removed during project work shall be reinstalled immediately after completion of work. All equipment and materials shall be removed from the NCDOT right-of-way when not in use. SC14 Any work requiring personnel or equipment within 5' of the travel lane on an undivided roadway, or 10' of the travel lane, on a divided roadway shall require a lane closure per the latest edition of the MUTCD and the NCDOT Standard Specifications. The more stringent standards shall apply. SC15 Approval is only for work within NCDOT right-of-way. Any construction planned or proposed outside NCDOT right- of- way shall require the permittee to obtain concurrence and/or right-of-way from subject property owner and/or local government. This approval excludes area(s) within Railroad right-of-way and/or Municipal right-of-way which will require separate approval from the Railroad, City or Town. Approval is with the understanding that NCDOT does not guarantee the right-of-way on any road. SC16 All traffic control, asphalt mixes, structures, construction, workmanship and construction methods, and materials shall be in compliance with the most-recent versions of the following resources: Manual on Uniform Traffic Control Devices, Policy on Street and Driveway Access to North Carolina Highways, Policies and Procedures for Accommodating Utilities on Highway Rights of Way, Subdivision Roads Minimum Construction Standards, NCDOT Standard Specifications for Roads Division 3, District 3 Updated 07/26/2023. and Structures, NCDOT Roadway Standard Drawings, AASHTO Policy on Geometric Design of Highways and Streets, NCDOT Asphalt Quality Management System manual, and the approved plans. SC17 Prior to beginning work, it is the requirement of the Permittee to contact the appropriate Utility Companies involved and make arrangements to adjust or relocate any utilities that conflict with the proposed work. SC18 NC 811 services DOES NOT provide locates of traffic signal cables. If the work is located within ½ mile of a signalized intersection, the Permittee shall contact NCDOT Traffic Services at (910) 341-2200 no less than one week prior to beginning work, for the location of all traffic signal and detection cables. Location is required prior to excavation. Cost to replace or repair NCDOT signs, signals or associated equipment shall be the responsibility of the Permittee. SC19 If modifications to a traffic signal are required under this permit, a separate traffic agreement is required prior to work. Contact the Division Traffic Engineer or Deputy Division Traffic Engineer at (910) 341-2200. SC20 If pavement markings are required under this permit, the permittee shall have the pavement markings pre-marked, inspected, and approved by NCDOT personnel prior to the placement of final pavement markings. Contact Traffic Services at (910) 341-2200 for pre-marking inspections or field changes. SC21 All concrete or paved channelization islands shall have a 12-inch diameter round or square smooth wall hole drilled, cored, formed, or air-hammered to the subgrade and backfilled with soil placed a minimum of 10 feet from the nose of each end of the island (see Roadway Standard Drawing 904.50), or as directed by the engineer. All sign supports that are to be erected in existing or proposed concrete or paved channelization islands shall meet the same requirements. If necessary, contact Traffic Services at (910) 341-2200 to mark core locations. SC22 Prior to beginning work, if the area of work is within a municipality limit, it is the responsibility of the Permittee to notify the municipal authorities. SC23 The Permittee shall comply with all applicable Federal, State, and local statutes, rules, regulations, and ordinances that may be imposed by other governmental agencies. The Permittee shall obtain all necessary Federal, State, and local environmental permits, including but not limited to, those related to sediment control, storm water, wetlands, streams, endangered species, and historical sites. SC24 All wiring and related work shall conform to the latest edition of the National Electrical Safety Code. SC25 No alteration of the approved plan will be allowed without written approval by NCDOT. All design plan changes proposed by the contractor shall be prepared by the Engineer of Record and submitted by the Owner/Permittee to NCDOT for review to ensure that the Engineer and Owner participate in all construction changes. Field changes constructed without prior written approval by NCDOT will not be accepted by NCDOT during the inspection process. SC26 An executed paper copy of the Driveway Permit and approved plans shall be present at the work site at all times while performing work. NCDOT reserves the right to stop all work unless evidence of approval can be shown. Additionally, NCDOT reserves the right to further limit, restrict, or suspend operations within the right-of-way. SC27 Material shall NOT be unloaded or stockpiled on the roadway at any time without proper lane closure during the project. Work is not permitted when the shoulder material is wet or during adverse weather conditions. SC28 All erosion control devices shall be placed as needed prior to disturbance and maintained throughout the project. All areas disturbed (shoulders, ditches, removed accesses, etc.) shall be graded and seeded within 15 calendar days with an approved NCDOT seed mixture. For disturbance of residential/commercial lawns, vegetation shall be replaced in like kind. SC29 For disturbance of plants, vegetation, trees or plant beds in the NCDOT right-of-way, they shall be replaced with plants, vegetation or trees of like kind or similar shape. Contact the Division Roadside Environmental Engineer at 910-259-4919. SC30 The placement of curb and gutter is not allowed within shoulder sections of roadway (from the Right of Way to the edge of pavement). SC31 It shall be the responsibility of the property owner or local municipality to maintain any proposed sidewalk that will be placed within the NCDOT Right of Way. It is the responsibility of the Permittee to place the sidewalk and wheelchair ramps per NCDOT standards and the latest edition of the Americans with Disabilities Act. This maintenance requires an encroachment agreement through the District Office. SC32 It shall be unlawful to place any highway obstruction, including a driveway headwall, fence, rural mailbox, newspaper delivery box, or other roadside obstruction, so as to interfere with the traffic or maintenance of the roads and highways of the state highway system. See North Carolina Administrative Code 19A NCAC 2E.0404. SC33 Fire Hydrant(s) shall be placed a maximum of 1 foot from the right-of-way line. (STD. 1515.02 in the NCDOT Roadway Standard Drawings). Division 3, District 3 Updated 07/26/2023. SC34 The Permittee shall comply with all OSHA requirements and provide a competent person on site to supervise excavation at all times. SC35 The Permittee is responsible for any and all damages caused from project work within the right-of-way, including damage to drainage structures, pavement, vegetation, etc. SC36 Any pavement damaged including settlement of the pavement or damage by equipment used to perform the project work, shall be re-surfaced to the satisfaction of the District Engineer or their representative. This may include the removal of pavement and a 50’ mechanical overlay. All temporary and final pavement markings are the responsibility of the Permittee. SC37 Centerline pavement markings shall be installed the same day resurfacing is accomplished. All other pavement markings shall be completed within five days of resurfacing. SC38 All pipes placed within the NCDOT Right of Way shall be NCDOT approved materials. All joints shall be sealed with mortar or other NCDOT approved material. Backfill compaction shall meet NCDOT Standardized Testing Method. SC39 Throughout the life of the project, the permittee shall maintain all drop-offs within the work zone such that they do not exceed the maximum of 2". SC40 All removed curb, driveways, and shoulder areas shall be backfilled at a 6:1 slope or flatter at the end of the days' production. SC41 Upon completion of construction, a certification memo that has been signed and sealed as appropriate under General Statute 89C-16 by a North Carolina Professional Engineer or Registered Land Surveyor shall be submitted to the District Engineer prior to opening the access connection for public use. Supporting documentation shall be attached certifying that improvements for the driveway access(s) meet the approved plan and NCDOT standards. All documentation shall be dated and initialed by the contractor. Verification will include inspection reports, testing reports, or any supporting documentation and calculations. Verification will cover, but is not limited to, subgrade, pavement structure, drainage, and traffic control items. SC42 It shall be unlawful for any person, firm, or corporation to erect, maintain, or operate upon his own land, or the land of another, any farm gate or other gate which, when opened, will project over the right-of-way of any State highway. Proposed gates are required to be located far enough from the edge of pavement so as not to interfere with roadway traffic flow; minimum 100’ from the Right of Way. See North Carolina General Statute 136-94. SC43 If this is a Temporary Driveway Permit then it is for temporary access only. All ingress/egress points for permanent access to this property shall be applied for per the Policy on Street and Driveway Access to North Carolina Highways. All Temporary Driveway Permits are for a 90-day period at which an extension will be required, or permanent request petitioned. SC44 The applicant/property owner shall be responsible to perform routine maintenance of the driveway(s) to ensure all applicable concrete median islands, traffic signs, pavement markings and reflectors remain in compliance as permitted. SC45 Sidewalk closures shall be installed, as necessary. Pedestrian traffic shall be detoured around these closures and shall be signed appropriately and in accordance with The American with Disabilities Act Accessibility Guidelines. The encroaching party must adhere to the guidelines for accommodating pedestrians in encroachment work zones as described in the NCDOT Pedestrian Work Zone Accommodations Training found at https://www.youtube.com/watch?v=AOuYa5IW3dg&feature=youtu.be STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION ROY COOPER J.ERIC BOYETTE GOVERNOR SECRETARY Mailing Address: NC DEPARTMENT OF TRANSPORTATION DISTRICT 3 ENGINEER’S OFFICE 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 04-11-03 COURIER Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 DATE: TO: FROM: August 17, 2023 Belinda West Accounting Tech IV General Ledger Unit Benjamin T. Hughes, PE District Engineer SUBJECT: Driveway Permit Inspection Fee D033-065-23-00017 US421 Townes at Park Place Permit Number: Road Number: Project: First National Bank 14771 $50.00 47900024 150245 3.106511 2712 BTH/bea Attachment cc: File Bank: Check #: Amount: GL Acct: Cost Ctr: WBS: Function: Paramounte Engineering, Inc 122 Cinema Drive Wilmington, NC 28403 D033-065-23-00017 STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION ROY COOPER J.ERIC BOYETTE GOVERNOR SECRETARY Mailing Address: NC DEPARTMENT OF TRANSPORTATION DIVISION OF HIGHWAYS 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 04-11-03 MAIL SERVICE CENTER Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 November 20, 2023 Memorandum To: Stephanie Benson Accounts Receivable From: Benjamin T. Hughes, PE District Engineer Subject: Driveway Permit Performance Indemnity Bond Permit Number: D033-065-23-00017 Road Number: US 421 Project: Townes at Park Place Health Grading and Utility, Inc. 2422 Wrightsville Avenue Wilmington, NC 28403 Surety: The Ohio Casualty Insurance Company Amount: $107,000.00 Upon satisfactory completion of this project, we will notify your office that a refund may be issued. BTH/tlb Attachment Cc: File COVER SHEET GENERAL NOTES AUGUST 2023 APPLICANT: THE TOWNES AT PARK PLACE FDCC LLC 128 S MAIN STREET, SUITE 2 SUMMERVILLE, NC 29483 NCDOT DRIVEWAY & OFFSITE TRAFFIC IMPROVEMENTS NEW HANOVER COUNTY, NORTH CAROLINA PROPERTY OWNER: NOTICE REQUIRED ALL EXISTING UNDERGROUND UTILITIES SHALL BE PHYSICALLY LOCATED PRIOR TO THE BEGINNING OF ANY CONSTRUCTION IN THE VICINITY OF SAID UTILITIES. CONTRACTORS SHALL NOTIFY OPERATORS WHO MAINTAIN UNDERGROUND UTILITY LINES IN THE AREA OF PROPOSED EXCAVATION AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN TEN WORKING DAYS PRIOR TO COMMENCEMENT OF EXCAVATION OR DEMOLITION. CONTRACTORS SHALL CONTACT OVERHEAD ELECTRIC PROVIDER TO COMPLY WITH FEDERAL OSHA 1910.333 MINIMUM APPROACH DISTANCE TO ENERGIZED POWERLINES AND OSH 29 CFR 1926.1407-1411 MUST BE FOLLOWED. Know what's below. before you dig.Call R PREPARED BY: PROJECT # 22321.PE FI N A L D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N 122 Cinema Drive Wilmington, North Carolina 28403 (910) 791-6707 (O) (910) 791-6760 (F) NC License #: C-2846 THE TOWNES AT PARK PLACE SHEET NUMBER SHEET TITLE PROJECT CONSULTANTS SHEET INDEX AUGUST 16, 2023 SURVEYOR PARAMOUNTE ENGINEERING, INC. 122 CINEMA DRIVE WILMINGTON, NC 28403 (910-791-6707) ENGINEER/ LAND PLANNER/ LANDSCAPE ARCHITECT PARAMOUNTE ENGINEERING, INC. 122 CINEMA DRIVE WILMINGTON, NC 28403 CIVIL: TIM CLINKSCALES, PE (910-791-6707) LANDSCAPE ARCHITECT: ALLISON ENGEBRETSON, RLA (910-791-6707) N O R T H C AROLIN A P R O F E SSION ENGI N E E R SEAL A L T I M O T HY G. C L I N K S C A LES 0 2 8 8 4 7 8/16/23 APPLICANT: GEOMETRIC & DEMO PLANC-8.1 C-1.0 C-0.0 STRIPING PLANC-8.2 VICINITY MAP SCALE: 1" = 1,000' NORTH C A R O L I N A B E A C H R D . CO L L E G E R D . CA R O L I N A B E A C H R D . ANT O I N E T T E D R . SITE CONTACT THESE UTILITIES NEW HANOVER COUNTY PLANNING DEPARTMENT ATTN: RON MEREDITH PH: 910-798-7165 PIEDMONT NATURAL GAS ATTN: CARL PAQUET PH: 910-350-2242 EMERGENCY DIAL 911 POLICE - FIRE - RESCUE CFPUA (WATER & SEWER) GENERAL PH: 919-332-6550 DUKE ENERGY PROGRESS GENERAL PH: 800-452-2777 AT&T ATTN: STEVE DAYVAULT PH: 910-341-7664 SPECTRUM GENERAL PH: 800-892-4357 C-8.3 C-8.4 C-8.5 - C-8.6 GRADING, DRAINAGE, & EC PLAN TRAFFIC CONTROL PLAN DRIVEWAY SITE PLANS C-8.7 DRAINAGE AREAS MAP C-8.8 - C-8.9 DETAILS TH E T O W N E S A T P A R K P L A C E NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 22321.PE FD C C L L C 12 8 S M A I N S T R E E T , S U I T E 2 SU M M E R V I L L E , S C 2 9 4 8 3 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL CL I E N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 GE N E R A L N O T E S 08 / 0 7 / 2 3 NT S DJ L DJ L TG C C-1.0 COORDINATION NOTES: 1.THE CONTRACTOR IS REQUIRED TO OBTAIN ANY/ALL PERMITS REQUIRED FOR CONSTRUCTION OF THESE PLANS. 2.ALL CONSTRUCTION TO BE IN ACCORDANCE WITH PERMITS ISSUED AND WITH NEW HANOVER COUNTY, CFPUA, AND THE STATE OF NORTH CAROLINA. 3.THE CONTRACTOR IS TO ESTABLISH AND CHECK ALL HORIZONTAL AND VERTICAL CONTROLS TO BE USED WITH THE PROJECT. IN ADDITION, THE CONTRACTOR IS TO COMPUTE THE LAYOUT OF THE ENTIRE SITE PLAN IN ADVANCE OF BEGINNING ANY WORK ASSOCIATED WITH THE SUBJECT PLANS. CONTRACTOR SHALL EMPLOY A PROFESSIONAL SURVEYOR TO PERFORM SITE IMPROVEMENT STAKEOUT(S). 4.ANYTIME WORK IS PERFORMED OFF-SITE OR WITHIN AN EXISTING EASEMENT, THE CONTRACTOR IS TO NOTIFY THE HOLDER OF SAID EASEMENT AS TO THE NATURE OF PROPOSED WORK, AND TO FOLLOW ANY GUIDELINES OR STANDARDS WHICH ARE ASSOCIATED WITH OR REFERENCED IN THE RECORDED EASEMENT. 5.CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS BY OTHERS FOR ALL BUILDING DIMENSIONS AND DETAILS. GENERAL NOTES: 1.TREE INVENTORY AND TOPOGRAPHIC SURVEY COMPLETED BY PARAMOUNTE ENGINEERING, INC. THE SURVEY SHALL BE FIELD VERIFIED BY CONTRACTOR AND ANY DISCREPANCIES REPORTED TO THE OWNER AND ENGINEER. 2.REASONABLE CARE HAS BEEN EXERCISED IN SHOWING THE LOCATION OF EXISTING UTILITIES ON THE PLANS. THE EXACT LOCATION OF ALL EXISTING UTILITIES IS NOT KNOWN IN ALL CASES. THE CONTRACTOR SHALL EXPLORE THE AREA AHEAD OF DITCHING OPERATIONS BY OBSERVATIONS, ELECTRONIC DEVICES, HAND DIGGING AND BY PERSONAL CONTACT WITH THE UTILITY COMPANIES. IN ORDER TO LOCATE EXISTING UTILITIES IN ADVANCE OF TRENCHING OPERATIONS SO AS TO ELIMINATE OR MINIMIZE DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS RESULTING FROM ANY DAMAGE TO THE EXISTING UTILITY LINES INCLUDING LOSS OF UTILITY REVENUES. CONTRACTOR SHALL ARRANGE FOR TEMPORARY SUPPORT OF EXISTING UTILITIES, SUCH AS POLES, CONDUITS, FIBER OPTIC CABLES, TELEPHONE CABLES, WATER LINES, ETC. 3.CONTRACTOR SHALL COMPLY WITH THE LATEST REVISIONS AND INTERPRETATIONS OF THE DEPARTMENT OF LABOR SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION PROMULGATED UNDER THE OCCUPATIONAL SAFETY AND HEALTH ACT. 4.CONTRACTOR SHALL PLAN AND CONSTRUCT WORK SO AS TO CAUSE MINIMUM INCONVENIENCE TO THE OWNER AND THE PUBLIC. THE CONTRACTOR SHALL PROVIDE, ERECT AND MAINTAIN AT ALL TIMES DURING THE PROGRESS OR TEMPORARY SUSPENSION OF WORK, SUITABLE BARRIERS, FENCES, SIGNS OR OTHER ADEQUATE PROTECTION, INCLUDING FLAGMEN AND WATCHMEN AS NECESSARY TO INSURE THE SAFETY OF THE PUBLIC AS WELL AS THOSE ENGAGED IN THE CONSTRUCTION WORK. CONSTRUCTION SIGNING SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF "CONSTRUCTION AND MAINTENANCE OPERATIONS SUPPLEMENT TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" BY THE USDOT. 5.ALL MATERIAL CLEARED OR DEMOLISHED BY THE CONTRACTOR IN ORDER TO CONSTRUCT THE WORK SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE PROPERLY DISPOSED OF OFF-SITE. 6.ALL WORK BY THE CONTRACTOR SHALL BE WARRANTED BY THE CONTRACTOR FOR A PERIOD OF ONE YEAR AFTER THE OWNER ACCEPTS THE WORK. 7. CONTRACTOR SHALL CALL THE NORTH CAROLINA ONE-CALL CENTER AT 811 AN ALLOW THE CENTER TO LOCATE EXISTING UTILITIES BEFORE DIGGING. 8. ANY DISCREPANCY IN THIS PLAN AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE OWNER PRIOR TO START OF CONSTRUCTION. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL SETBACKS, EASEMENTS AND DIMENSIONS SHOWN HEREON BEFORE BEGINNING CONSTRUCTION. 9. CONTRACTOR SHALL MAINTAIN THE SITE IN A MANNER SO THAT WORKMEN AND PUBLIC SHALL BE PROTECTED FROM INJURY, AND ADJOINING PROPERTY PROTECTED FROM DAMAGE. 10. ACCESS TO UTILITIES, FIRE HYDRANTS, STREET LIGHTING, ETC., SHALL REMAIN UNDISTURBED, UNLESS COORDINATED WITH THE RESPECTIVE UTILITY. 11. DO NOT SCALE THIS DRAWING AS IT IS A REPRODUCTION AND SUBJECT TO DISTORTION. 12. THE GENERAL CONTRACTOR SHALL REMOVE ALL DEBRIS FROM THE SITE UPON COMPLETION OF THE PROJECT AND AT LEAST ONCE A WEEK DURING CONSTRUCTION. 13. THE GENERAL CONTRACTOR SHALL KEEP THE AREA OUTSIDE THE "CONSTRUCTION LIMITS" BROOM CLEAN AT ALL TIMES. 14. ALL STREET SURFACES, DRIVEWAYS, CULVERTS, CURB AND GUTTERS, ROADSIDE DRAINAGE DITCHES AND OTHER STRUCTURES THAT ARE DISTURBED OR DAMAGED IN ANY MANNER AS A RESULT OF CONSTRUCTION SHALL BE REPLACED OR REPAIRED IN ACCORDANCE WITH THE SPECIFICATIONS. 15. CONTRACTOR SHALL MAINTAIN AN "AS-BUILT" SET OF DRAWINGS TO RECORD THE EXACT LOCATION OF ALL PIPING PRIOR TO CONCEALMENT. DRAWINGS SHALL BE GIVEN TO THE OWNER UPON COMPLETION OF THE PROJECT WITH A COPY OF THE TRANSMITTAL LETTER TO THE ENGINEER. 16. IF DEPARTURES FROM THE SPECIFICATIONS OR DRAWINGS ARE DEEMED NECESSARY BY THE CONTRACTOR, DETAILS OF SUCH DEPARTURES AND REASONS THEREOF SHALL BE GIVEN TO THE OWNER FOR REVIEW, NO DEPARTURES FROM THE CONTRACT DOCUMENTS SHALL BE MADE WITHOUT THE PERMISSION OF THE OWNER, NEW HANOVER COUNTY, OR CFPUA, RESPECTIVELY. 17. CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES. THE LOCATION OF ALL EXISTING UTILITIES ARE NOT NECESSARILY SHOWN ON PLANS AND WHERE SHOWN ARE ONLY APPROXIMATE. THE CONTRACTOR SHALL ON HIS INITIATIVE AND AT NO EXTRA COST HAVE LOCATED ALL UNDERGROUND LINES AND STRUCTURES AS NECESSARY. NO CLAIMS FOR DAMAGES OR EXTRA COMPENSATION SHALL ACCRUE TO THE CONTRACTOR FROM THE PRESENCE OF SUCH PIPE OTHER OBSTRUCTIONS OR FROM DELAY DUE TO REMOVAL OR REARRANGEMENT OF THE SAME. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO UNDERGROUND STRUCTURES. CONTACT NORTH CAROLINA ONE CALL" TOLL FREE 1-800-632-4949 AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING ALL NONSUBSCRIBING UTILITIES. 18. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL INSPECTIONS, CERTIFICATIONS, EQUIPMENT, ETC., THAT MAY BE REQUIRED. 19. THE ENGINEER AND/OR OWNER DISCLAIM ANY ROLE IN THE CONSTRUCTION MEANS AND METHODS ASSOCIATED WITH THE PROJECT AS SET FORTH IN THESE PLANS. 20. ALL LOT STRIPING AND DIRECTIONAL ARROWS TO BE REFLECTIVE MARKINGS AND SHALL CONFORM TO MUTCD. ALL PARKING STALL MARKINGS AND LANE ARROWS WITHIN THE PARKING AREAS SHALL BE WHITE. 21. LANDSCAPE PLANTINGS AT ENTRANCE/ EXITS WILL BE INSTALLED AND MAINTAINED SO AS NOT TO INTERFERE WITH SIGHT DISTANCE NEEDS OF DRIVERS IN THE PARKING AREA AND AT ENTRANCE/EXIT LOCATIONS PER LOCAL STANDARDS. 22. ALL DIMENSIONS AND RADII ARE TO OUTSIDE FACE OF BUILDING OR TO FACE OF CURB UNLESS OTHERWISE NOTED. DEMOLITION NOTES: 1. CONTRACTOR TO COORDINATE WITH THE OWNER TO PROPERLY MAINTAIN OR RELOCATE EXISTING SERVICE CONNECTIONS WHEN NECESSARY. 2. CONTRACTOR IS TO WALK THE SITE AND BECOME FAMILIAR WITH THE SCOPE OF DEMOLITION REQUIRED. ALL DEMOLITION WORK REQUIRED TO CONSTRUCT NEW SITE IMPROVEMENTS WILL BE PERFORMED BY THE CONTRACTOR AND WILL BE CONSIDERED UNCLASSIFIED EXCAVATION. 3. DEMOLITION SHALL INCLUDE BUT IS NOT LIMITED TO THE EXCAVATION, HAULING AND OFFSITE DISPOSAL OF CONCRETE PADS, CONCRETE DITCHES, FOUNDATIONS, SLABS, STEPS, AND STRUCTURES; ABANDONED UTILITIES, BUILDINGS, PAVEMENTS AND ALL MATERIALS CLEARED AND STRIPPED TO THE EXTENT NECESSARY AS DIRECTED BY THE GEOTECHNICAL ENGINEER FOR THE INSTALLATION OF THE NEW IMPROVEMENTS AND WITHIN THE LIMITS OF CLEARING AND GRADING AND AS SHOWN ON THESE PLANS. 4. THE CONTRACTOR SHALL PROTECT ALL ADJACENT PROPERTY, STRUCTURES AND UTILITIES ON THE PROPERTY NOT TO BE DEMOLISHED. DAMAGE TO PROPERTIES OF OTHERS DUE TO THE CONTRACTOR'S ACTIVITIES SHALL BE REPLACED IN KIND BY THE CONTRACTOR AT NO COST TO OWNER. 5. ELECTRIC, TELEPHONE, SANITARY SEWER, WATER AND STORM SEWER UTILITIES THAT SERVICE OFF-SITE PROPERTIES SHALL BE MAINTAINED DURING THE CONSTRUCTION PROCESS BY THE CONTRACTOR. 6. THE CONTRACTOR SHALL PRODUCE A PHOTOGRAPHIC RECORD (DIGITAL) OF DEVELOPMENT COMMENCING WITH A RECORD OF THE SITE AS IT APPEARS BEFORE DEMOLITION HAS BEGUN. AFTERWARDS, A PHOTOGRAPHIC RECORD SHALL BE MAINTAINED WEEKLY DURING CONSTRUCTION AND ENDING WITH A PHOTOGRAPHIC RECORD OF THE DEVELOPMENT AS IT APPEARS AFTER DEMOLITION. THIS RECORD SHALL BE DELIVERED TO THE OWNER. 7. EXISTING CURB AND GUTTER, LIGHTS, SIDEWALK, AND UTILITIES NOT INTENDED FOR DEMOLITION SHALL BE MAINTAINED, PROTECTED AND UNDISTURBED DURING DEMOLITION. 8. ALL EXISTING IMPROVEMENTS INDICATED OR REQUIRED TO BE DEMOLISHED SHALL INCLUDE REMOVAL FROM THE PROPERTY AND PROPER DISPOSAL. 9. CONTRACTOR SHALL COORDINATE RELOCATION OF ALL EXISTING OVERHEAD AND UNDERGROUND UTILITIES INCLUDING CABLE, GAS, TELEPHONE AND ELECTRIC AND ANY OTHER UTILITIES THROUGH THE SITE WITH THE RESPECTIVE COMPANIES. 10. CONTRACTOR SHALL MAINTAIN REQUIRED DISTANCES FROM HIGH VOLTAGE OVERHEAD LINES AND REMOVE TREES SO THEY DO NOT FALL TOWARDS OVERHEAD ELECTRICITY. 11. PROVIDE SMOOTH SAW CUT OF EXISTING PAVEMENTS, CURBS AND GUTTERS AND SIDEWALKS TO BE DEMOLISHED. 12. ALL DEMOLITION WORK SHALL BE DONE IN STRICT ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS AS WELL AS OSHA REGULATIONS. 13. EXISTING FIRE HYDRANTS ON OR NEAR THE SITE ARE TO REMAIN IN SERVICE. 14. INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS, BUT THE CONTRACTOR MUST DETERMINE THE EXACT LOCATION AND ELEVATIONS. ROOF DRAIN NOTE: 1)PROPOSED BUILDING SHALL DIVERT ROOF DRAINAGE TO STORMWATER COLLECTION SYSTEM. WETLAND NOTES: 1)THERE ARE WATERS OF THE U.S. ON THE PROPERTY AS SHOWN. GENERAL STORM SEWER NOTES 1. ALL STORM SEWERS SHALL BE CONSTRUCTED IN ACCORDANCE WITH NEW HANOVER COUNTY REQUIREMENTS AS SPECIFIED ON THE DRAWINGS AND IN THE PROJECT SPECIFICATIONS. 2. BEDDING FOR ALL STORM SEWER PIPE SHALL BE AS SPECIFIED ON THE DRAWINGS. 3. ALL STORM SEWER PIPES SHOWN AS RCP ON THE PLANS SHALL BE REINFORCED CONCRETE PIPE CONFORMING TO ASTM C-76, UNLESS INDICATED OTHERWISE ON PLANS. NC ACCESSIBILITY NOTES: GENERAL NOTES: 1.SPECIAL ATTENTION SHALL BE GIVEN TO COMPLIANCE WITH AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NORTH CAROLINA BUILDING CODE/ANSI A117.1, AND APPLICABLE LOCAL LAWS & REGULATIONS. 2.IT IS ESSENTIAL THAT CONTRACTORS ARE AWARE OF THE SITE ACCESSIBILITY REQUIREMENTS. PARAMOUNTE ENGINEERING HAS DEVELOPED THESE NOTES AND DETAILS TO ASSURE THAT CONTRACTORS ARE AWARE OF THE REQUIREMENTS AT THE POINT IN TIME WHEN THEY ARE BIDDING THE PROJECT. IN ADDITION, PARAMOUNTE ENGINEERING HAS MADE A POINT IN THESE NOTES AND DETAILS, AS WELL AS IN OUR DRAWINGS, TO PROVIDE SLOPES / GRADES AND DIMENSIONS THAT COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NORTH CAROLINA BUILDING CODE/ANSI A117.1 AND APPLICABLE LOCAL LAWS & REGULATIONS. IF THESE SLOPES / GRADES AND DIMENSIONS ARE NOT ACHIEVABLE, THE CONTRACTOR IS REQUIRED TO CONTACT THE OWNER IMMEDIATELY AND BEFORE MOVING FORWARD WITH THE WORK. 3. THE CONTRACTOR SHALL NOTIFY PARAMOUNTE ENGINEERING IMMEDIATELY OF ANY CONFLICT BETWEEN THESE NOTES AND DETAILS AND OTHER PROJECT DRAWINGS, WHETHER BY PARAMOUNTE ENGINEERING OR OTHERS. THE CONTRACTOR SHALL NOT PROCEED WITH THE WORK FOR WHICH THE ALLEGED CONFLICT HAS BEEN DISCOVERED UNTIL SUCH ALLEGED CONFLICT HAS BEEN RESOLVED. NO CLAIM SHALL BE MADE BY THE CONTRACTOR FOR DELAY OR DAMAGES AS A RESULT OF RESOLUTION OF ANY SUCH CONFLICT(S). 4.THESE ACCESSIBILITY NOTES AND DETAILS ARE INTENDED TO DEPICT SLOPE AND DIMENSIONAL REQUIREMENTS ONLY. REFER TO SIDEWALK, CURBING, AND PAVEMENT DETAILS FOR ADDITIONAL INFORMATION. ACCESSIBLE ROUTE NOTES: 1.AT LEAST ONE ACCESSIBLE ROUTE SHALL BE PROVIDED WITHIN THE SITE FROM ACCESSIBLE PARKING SPACES AND ACCESSIBLE PASSENGER LOADING ZONES; PUBLIC STREETS OR SIDEWALKS; AND PUBLIC TRANSPORTATION STOPS TO THE ACCESSIBLE BUILDING OR FACILITY ENTRANCE THEY SERVE. 2.AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDINGS, ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS, AND ACCESSIBLE SPACES THAT ARE ON THE SAME SITE. 3.WALKING SURFACES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL HAVE A MAXIMUM RUNNING SLOPE OF 5.0% AND A MAXIMUM CROSS SLOPE OF 2.0%. 4.ANY WALKING SURFACE THAT IS PART OF AN ACCESSIBLE ROUTE WITH A RUNNING SLOPE GREATER THAN 5.0% IS A RAMP AND SHALL COMPLY WITH THE GUIDELINES FOR RAMPS OR CURB RAMPS. 5.TRANSITIONS BETWEEN RAMPS, WALKS, LANDINGS, GUTTERS OR STREETS SHALL BE FLUSHAND FREE OF ABRUPT VERTICAL CHANGES (1/4 INCH MAXIMUM VERTICAL CHANGE IN LEVEL PERMITTED). 6.FLOOR SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANT. 7.THE MINIMUM CLEAR WIDTH OF EXTERIOR ACCESSIBLE ROUTES SHALL BE FORTY-EIGHT (48) INCHES MINIMUM MEASURED BETWEEN HANDRAILS WHERE HANDRAILS ARE PROVIDED (NC BUILDING CODE 1104.1 & 1104.2). 8.WHERE AN ACCESSIBLE ROUTE MAKES A 180 DEGREE TURN AROUND AN OBJECT THAT IS LESS THAN FORTY-EIGHT (48) INCHES IN WIDTH, CLEAR WIDTH SHALL BE FORTY-TWO (42) INCHES MINIMUM APPROACHING THE TURN, FORTY-EIGHT (48) INCHES MINIMUM DURING THE TURN, AND FORTY-TWO (42) INCHES MINIMUM LEAVING THE TURN. THE CLEAR WIDTH APPROACHING AND LEAVING THE TURN MAY BE THIRTY-SIX (36) INCHES MINIMUM WHEN THE CLEAR WIDTH AT THE TURN IS SIXTY (60) INCHES MINIMUM. .* SEE NOTE 7 ABOVE FOR NC CLEAR WIDTH OF EXTERIOR ACCESSIBLE ROUTES* 9.AN ACCESSIBLE ROUTE WITH A CLEAR WIDTH LESS THAN SIXTY (60) INCHES SHALLPROVIDE PASSING SPACES AT INTERVALS OF TWO HUNDRED (200) FEET MAXIMUM. PASSING SPACES SHALL BE EITHER A SIXTY (60) INCH MINIMUM BY SIXTY (60) INCH MINIMUM SPACE; OR AN INTERSECTION OF TWO (2) WALKING SURFACES THAT PROVIDE A COMPLIANT T-SHAPED TURNING SPACE, PROVIDED THE BASE AND ARMS OF THE T-SHAPED SPACE EXTEND FORTY-EIGHT (48) INCHES MINIMUM BEYOND THE INTERSECTION. 10.DOORS, DOORWAYS AND GATES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NORTH CAROLINA BUILDING CODE/ ANSI A117.1, AND APPLICABLE LOCAL LAWS & REGULATIONS. 11.DIRECTIONAL SIGNAGE INDICATING THE ROUTE TO THE NEAREST ACCESSIBLE BUILDING ENTRANCE SHALL BE PROVIDED AT INACCESSIBLE BUILDING ENTRANCES. 12. WHERE POSSIBLE, DRAINAGE INLETS SHALL NOT BE LOCATED ON AN ACCESSIBLE ROUTE. IN THE EVENT THAT A DRAINAGE INLET MUST BE LOCATED ON AN ACCESSIBLE ROUTE, THE GRATE SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), A117.1, THE NC BUILDING CODE, AND APPLICABLE LOCAL LAWS & REGULATIONS RAMP NOTES: 1.ANY PART OF AN ACCESSIBLE ROUTE WITH A RUNNING SLOPE GREATER THAN 5% SHALL BE CONSIDERED A RAMP. 2.THE MAXIMUM RUNNING SLOPE FOR A RAMP SHALL BE 8.33% AND THE MAXIMUM CROSS SLOPE SHALL BE 2.0%. 3.THE CLEAR WIDTH OF AN EXTERIOR RAMP RUN SHALL BE FORTY EIGHT INCHES (NC BUILDING CODE 1104.1). WHERE HANDRAILS ARE PROVIDED ON THE RAMP RUN, THE CLEAR WIDTH SHALL BE MEASURED BETWEEN THE HANDRAILS. 4.THE RISE FOR ANY RAMP RUN SHALL BE THIRTY (30) INCHES MAXIMUM. 5. LANDINGS SHALL BE PROVIDED AT THE TOP AND BOTTOM OF RAMPS. LANDINGS SHALL HAVE A SLOPE NOT STEEPER THAN 2.0% IN ANY DIRECTION. THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE WIDEST RAMP RUN LEADING TO THE LANDING. THE LANDING CLEAR LENGTH SHALL BE SIXTY (60) INCHES LONG MINIMUM. RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR LANDING OF SIXTY (60) INCHES BY SIXTY (60) INCHES MINIMUM. 6.RAMP RUNS WITH A RISE GREATER THAN SIX (6) INCHES SHALL HAVE HANDRAILS ON BOTH SIDES COMPLYING WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NC BUILDING CODE/ANSI A117.1, AND APPLICABLE LOCAL LAWS & REGULATIONS. 7. FLOOR SURFACES OF RAMPS AND LANDINGS SHALL BE STABLE, FIRM AND SLIP RESISTANT. 8.EDGE PROTECTION COMPLYING WITH AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NC BUILDING CODE/ANSI A117.1, AND APPLICABLE LOCAL LAWS & REGULATIONS SHALL BE PROVIDED ON EACH SIDE OF RAMP RUNS AND ON EACH SIDE OF RAMP LANDINGS. 9.WHERE DOORWAYS ARE LOCATED ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NC BUILDING CODE/ANSI A117.1 SHALL BE PERMITTED TO OVERLAP THE REQUIRED LANDING AREA. WHERE DOORS THAT ARE SUBJECT TO LOCKING ARE ADJACENT TO A RAMP LANDING, LANDINGS SHALL BE SIZED TO PROVIDE A COMPLIANT TURNING SPACE. CURB RAMP NOTES: 1.THE MAXIMUM RUNNING SLOPE OF A CURB RAMP SHALL BE 8.33% AND THE MAXIMUM CROSS SLOPE SHALL BE 2.0%. 2.COUNTER SLOPES OF ADJOINING GUTTERS AND ROAD SURFACES IMMEDIATELY ADJACENT TO THE CURB RAMP SHALL NOT BE STEEPER THAN 5%. THE ADJACENT SURFACES AT TRANSITIONS AT CURB RAMPS TO WALKS, GUTTERS AND STREETS SHALL BE AT THE SAME LEVEL. 3.THE CLEAR WIDTH OF A CURB RAMP SHALL BE 36 INCHES (36) MINIMUM, EXCLUSIVE OF FLARED SIDES, IF PROVIDED. *NOTE NC BUILDING CODE REQUIRES EXTERIOR ACCESSIBLE ROUTES TO BE 48 INCHES MINIMUM WIDE (1104.1 & 1104.2).* 4.LANDINGS SHALL BE PROVIDED AT THE TOP OF CURB RAMPS. THE CLEAR LENGTH OF THE LANDING SHALL BE THIRTY-SIX (36) INCHES MINIMUM. THE CLEAR WIDTH OF THE LANDING SHALL BE AT LEAST AS WIDE AS THE CURB RAMP, EXCLUDING FLARED SIDES, LEADING TO THE LANDING. LANDINGS SHALL HAVE A SLOPE NOT STEEPER THAN 2% IN ANY DIRECTION. 5.IF A CURB RAMP IS LOCATED WHERE PEDESTRIANS MUST WALK ACROSS THE RAMP, OR WHERE IT IS NOT PROTECTED BY HANDRAILS OR GUARDRAILS, IT SHALL HAVE FLARED SIDES. 6.WHERE PROVIDED, CURB RAMP FLARES SHALL NOT EXCEED 10%. 7.CURB RAMPS AND THE FLARED SIDES OF CURB RAMPS SHALL BE LOCATED SO THAT THEY DO NOT PROJECT INTO VEHICULAR TRAFFIC LANES, PARKING SPACES OR PARKING ACCESS AISLES. CURBS AT MARKED CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THE MARKINGS, EXCLUDING ANY FLARED SIDES. 8.CURB RAMPS SHALL BE LOCATED OR PROTECTED TO PREVENT THEIR OBSTRUCTION BY PARKED VEHICLES. 9.IT IS RECOMMENDED TO PROVIDE CURB RAMPS WITH A TWENTY-FOUR (24) INCH DEEP DETECTABLE WARNING COMPLYING WITH 406.12 A117.1, EXTENDING THE FULL WIDTH OF THE RAMP. REFERTO DETECTABLE WARNING DETAILS AND NOTES FOR PLACEMENT, ORIENTATION AND NOTES. THE NC BUILDING CODE DOES NOT CURRENTLY REQUIRE DETECTABLE WARNINGS AT CURB RAMPS, NOR DO THE 2010 ADA STANDARDS - HOWEVER US DOT ADA REGULATIONS DO REQUIRE THESE. 10.FLOOR SURFACES OF CURB RAMPS SHALL BE DEEP GROOVED, ½ INCH WIDE BY ¼ INCH DEEP, ONE (1) INCH CENTERS TRANSVERSE TO THE RAMP. 11.WHERE PROVIDED, STOP LINES SHALL BE LOCATED IN ADVANCE OF CURB RAMP. 12.WHERE PROVIDED, PEDESTRIAN ACTIVATED SIGNALS SHALL BE LOCATED ADJACENT TO THE SIDEWALK AND NOT ON THE SIDEWALK. 13.WHERE PROVIDED, DRAINAGE INLETS SHALL BE LOCATED UPSTREAM OF CURB RAMPS AND NOT IN THE RAMP AREA. 14.CURB RAMP TYPE AND LOCATION ARE PER PLAN. GENERAL EROSION AND SEDIMENT CONTROL NOTES: 1. THE EROSION CONTROL PLAN SHALL INCLUDE PROVISIONS FOR GROUNDCOVER ON ALL EXPOSED PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES AND ALL SLOPES STEEPER THAN 3:1 WITHIN 7 CALENDAR DAYS FROM THE LAST LAND DISTURBING ACTIVITY. GROUND COVER SHALL BE PROVIDED ON ALL OTHER DISTURBED AREAS WITHIN 14 CALENDAR DAYS FROM THE LAST LAND DISTURBING ACTIVITY. 2. UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CONSTRUCTED AND MAINTAINED IN ACCORDANCE WITH THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL HANDBOOK. 3. THE CONTRACTOR SHALL NOTIFY PLAN APPROVING AUTHORITY ONE WEEK PRIOR TO THE PRE-CONSTRUCTION CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE WEEK PRIOR TO FINAL INSPECTION. 4. ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO CLEARING AND/OR LAND DISTURBANCE. 5. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN AND PERMIT SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. 6. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO OFF-SITE BORROW OR WASTE AREAS STAGING OR STORAGE AREAS), THE CONTRACTOR SHALL PREPARE AND SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND TO NEW HANOVER COUNTY FOR APPROVAL. CONTRACTOR SHALL PAY ALL FEES REQUIRED AND SHALL INSTALL NECESSARY MEASURES AT NO SEPARATE PAYMENT. THE CONTRACTOR SHALL PROVIDE THE OWNER AND THE ENGINEER A COPY OF THE AMENDED PERMIT. 7.THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY EITHER THE REVIEWING AGENCY OR THE ENGINEER.. 8.ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION IS ACHIEVED. 9.ALL AREAS DISTURBED BY CONSTRUCTION UNLESS OTHERWISE IMPROVED SHALL BE SODDED OR SEEDED AS INDICATED AND STABILIZED. 10.DURING DEWATERING OPERATIONS, WATER SHALL BE PUMPED INTO AN APPROVED FILTERING DEVICE PRIOR TO DISCHARGE TO RECEIVING OUTLET. 11. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH RUNOFF-PRODUCING EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. 12. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED BY CONTRACTOR ONCE STABILIZATION OR A SUFFICIENT GROUND COVER HAS BEEN ESTABLISHED OR AS DIRECTED BY THE ENGINEER. 13. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE SHALL BE REQUIRED AT ALL CONSTRUCTION STAGING AREA ENTRANCES AND ALL CONSTRUCTION ACCESS LOCATIONS INTO NON-PAVED AREA. 14. WHEN CROSSING CREEK OR DRAINAGE-WAY, THE DIVISION OF WATER QUALITY SHALL BE CONTACTED PRIOR TO DISTURBING A CREEK. THE CONTRACTOR SHALL INSTALL RIP-RAP WITH FABRIC ALONG DISTURBED BANKS AND CHANNEL AND RESTORE SLOPES TO ORIGINAL CONTOURS, BUT NOT STEEPER THAN 2:1 MAXIMUM. DISTURBED CREEK AREA SHALL BE STABILIZED IMMEDIATELY. EROSION CONTROL AND SEQUENCE OF CONSTRUCTION NOTES: NOTE: THESE EROSION CONTROL AND SEQUENCE OF CONSTRUCTION NOTES ARE INTENDED FOR EACH "PHASE" OF CONSTRUCTION. THE ORDER AND STEPS TAKEN MUST BE IMPLEMENTED AS EACH PART OF THE PROJECT IS DEVELOPED; WHETHER AS A WHOLE OR IN PHASES. ANY EROSION CONTROL DEVICES/MEASURES MUST REMAIN IN PLACE UNTIL THE ENTIRE DISTURBANCE IS STABILIZED AND ALL IMPROVEMENTS WITHIN THE DISTURBANCE LIMITS ARE COMPLETE. 1. CONSTRUCT TEMPORARY GRAVEL CONSTRUCTION ENTRANCE(S), ESTABLISH THE LIMITS OF DISTURBANCE, AND TEMPORARY SILT FENCE. 2. CLEAR AND REMOVE FROM SITE TREES AS DESIGNATED, ROOTS, ROOT MAT, ETC. FROM THE AREA WITHIN THE DESIGNATED CLEARING LIMITS. 3. INSTALL REMAINING EROSION CONTROL MEASURES AS SHOWN ON THE PLANS WITHIN THE AREA DISTURBED. ALL EROSION CONTROL MEASURES MUST BE INSTALLED BEFORE COMMENCING CONSTRUCTION. 4. PLANT GRASS OVER ALL GRADED AREAS WITHIN 14 WORKING DAYS OF CEASE OF ANY GRADING ACTIVITY. 5. IMMEDIATELY UPON THE INSTALLATION OF ANY STORM DRAINAGE CATCH BASIN, DROP INLET, ETC., THE CONTRACTOR SHALL INSTALL INLET PROTECTION TO PREVENT SEDIMENT FROM ENTERING THE DRAINAGE SYSTEM. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING AND RESTORING TO PRE-CONSTRUCTION CONDITIONS ANY AREAS OUTSIDE THE PROJECT LIMITS THAT MAY INADVERTENTLY BE DAMAGED DUE TO THE FAILURE OF THE EROSION CONTROL MEASURES. 7. DURING GRADING AND AFTER GRADING HAS BEEN COMPLETE, THE CONTRACTOR SHALL CONTINUE TO MAINTAIN PERMANENT AND TEMPORARY EROSION CONTROL MEASURES UNTIL FINAL APPROVAL BY ENGINEER OR EROSION CONTROL INSPECTOR. 8. UPON RECEIVING FINAL APPROVAL, THE CONTRACTOR CAN REMOVE TEMPORARY EROSION CONTROL MEASURES. 9. THE CONTRACTOR SHALL CONTINUE TO WATER, FERTILIZE, MOW AND MAINTAIN GRASS & PLANTED AREAS UNTIL ALL CONSTRUCTION IS COMPLETE. EROSION CONTROL MAINTENANCE PLAN: 1. ALL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY 1/2-INCH OR GREATER RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS WILL BE MADE IMMEDIATELY TO MAINTAIN ALL PRACTICES AS DESIGNED. 2. ALL CONSTRUCTION ENTRANCES WILL BE PERIODICALLY TOP DRESSED WITH AN ADDITIONAL 2 INCHES OF #4 STONE TO MAINTAIN PROPER DEPTH. ANY SEDIMENT THAT IS TRACKED INTO THE STREET WILL BE IMMEDIATELY REMOVED. 3. SEDIMENT FENCE / SEDIMENT FENCE OUTLETS - SEDIMENT WILL BE REMOVED BEHIND THE SEDIMENT FENCE WHEN IT BECOMES HALF-FILLED. THE SEDIMENT FENCE WILL BE BE REPAIRED AS NECESSARY TO MAINTAIN A BARRIER. STAKES MUST BE STEEL, AND SPACED 6 FEET WITH EXTRA STRENGTH FABRIC AND NO WIRE BACKING. STAKE SPACING CAN BE 8 FEET WHEN STANDARD STRENGTH FABRIC AND WIRE BACKING ARE USED. IF ROCK FILTERS (OR EXCELSIOR WATTLES) ARE DESIGNED AT LOW POINTS IN THE SEDIMENT FENCE THE ROCK OR WATTLE WILL BE REPAIRED OR REPLACED IF IT BECOMES HALF FULL OF SEDIMENT, NO LONGER DRAINS, OR IS DAMAGED. 4. ALL SEEDED AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED ACCORDING TO SPECIFICATIONS ON THESE PLANS AND CONTRACT SPECIFICATIONS TO MAINTAIN A VIGOROUS, DENSE VEGETATIVE COVER. 5. INLET PROTECTION - SEDIMENT SHALL BE REMOVED FROM HARDWARE CLOTH AND GRAVEL, BLOCK AND GRAVEL, OR ROCK-PIPE INLETS, WHEN IT REACHES HALF-FILLED. ROCK WILL BE CLEANED OR REPLACED WHEN NO LONGER DRAINS. SILT SACKS, BEAVER DAMS, SANDY SACKS, AND SOCKS NEED CHECKING EVERY WEEK AND AFTER RAIN. 6. OUTLET PROTECTION - INSPECT RIP RAP OUTLET STRUCTURES WEEKLY AND AFTER RAINFALL EVENTS TO SEE IF ANY EROSION AROUND OR BELOW THE RIP RAP HAS TAKEN PLACE, OR IF STONES HAVE BEEN DISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER OFFSITE SEDIMENTATION. 7. EMERGENCY SPILLWAY / FOREBAY PROTECTION - AFTER EVERY HIGH-WATER EVENT INSPECT THE INTEGRITY OF THE LINED SPILLWAY AND THE ADJACENT EARTHEN BANKS. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE. REPAIR ANY VOIDS IN THE RIP RAP LINED APRONS. RE-ESTABLISH ANY LOOSE STONES, AND FIX GAPS IN THE ADJACENT VEGETATIVE COVER. 8. CONCRETE WASHOUTS - CONCRETE WASHOUTS SHOULD BE INSPECTED DAILY AND AFTER HEAVY RAINS. DAMAGES SHOULD BE REPAIRED PROMPTLY. IF FILLED TO OVER 75% CAPACITY WITH RAIN WATER IT SHOULD BE VACUUMED OR ALLOWED TO EVAPORATE TO AVOID OVERFLOWS. BEFORE HEAVY RAINS THE CONTAINERS LIQUID LEVEL SHOULD BE LOWERED OR THE CONTAINER COVERED TO AVOID AN OVER FLOW DURING RAIN. WHEN SOLIDS HAVE HARDENED THEY SHOULD BE REMOVED AND RECYCLED. NC ACCESSIBILITY NOTES CONTD. PARKING SPACE NOTES: 1.ACCESSIBLE PARKING SPACES SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE ROUTES OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE BUILDING ENTRANCE. 2.ACCESSIBLE PARKING SPACES SHALL BE AT LEAST NINETY-SIX (96) INCHES WIDE. ACCESS AISLES SHALL BE 60 INCHES WIDE. ONE OF SIX ACCESSIBLE SPACES SHOULD PROVIDE A VAN ACCESSIBLE AISLE. THE AISLE SHOULD BE 96 INCHES WIDE (OR ACCESSIBLE SPACE IS 11 FEET AND ACCESS AISLE IS FIVE FEET). WHERE PARKING SPACES AND ACCESS AISLES ARE MARKED WITH LINES, THE WIDTH MEASUREMENTS SHALL BE MADE FROM CENTERLINE OF THE MARKINGS. WHERE PARKING SPACES OR ACCESS AISLES ARE NOT ADJACENT TO ANOTHER PARKING SPACE OR ACCESS AISLES, MEASUREMENTS SHALL BE PERMITTED TO INCLUDE THE FULL WIDTH OF THE LINE DEFINING THE PARKING SPACE OR ACCESS AISLE. 3.PARKING ACCESS AISLES SHALL BE PART OF AN ACCESSIBLE ROUTE TO THE BUILDING OR FACILITY ENTRANCE AND SHALL COMPLY WITH PROVISIONS FORACCESSIBLE ROUTES. MARKED CROSSINGS SHALL BE PROVIDED WHERE THE ACCESSIBLE ROUTE MUST CROSS VEHICULAR TRAFFIC LANES. WHERE POSSIBLE, IT IS PREFERABLE THAT THE ACCESSIBLE ROUTE NOT PASS BEHIND PARKED VEHICLES. 4.TWO (2) ACCESSIBLE PARKING SPACES MAY SHARE A COMMON ACCESS AISLE. 5.ACCESS AISLES SHALL EXTEND THE FULL LENGTH OF THE PARKING SPACE THEY SERVE. 6.ACCESS AISLES SHALL BE MARKED SO AS TO DISCOURAGE PARKING IN THEM. 7.ACCESS AISLES SHALL NOT OVERLAP THE VEHICULAR WAY. ACCESS AISLES SHALL BE PERMITTED TO BE PLACED ON EITHER SIDE OF THE PARKING SPACE EXCEPTFOR ANGLED VAN PARKING SPACES WHICH SHALL HAVE ACCESS AISLES LOCATED ON THE PASSENGER SIDE OF THE PARKING SPACES. 8.FLOOR SURFACES OF PARKING SPACES AND ACCESS AISLES SERVING THEM SHALL BE STABLE, FIRM AND SLIP RESISTANT. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING SPACES THEY SERVE. CHANGES IN LEVEL ARE NOT PERMITTED. 9.PARKING SPACES AND ACCESS AISLES SHALL BE LEVEL WITH SURFACE SLOPES NOT EXCEEDING 2.0% IN ALL DIRECTIONS. 10.PARKED VEHICLE OVERHANGS SHALL NOT REDUCE THE REQUIRED CLEAR WIDTH OF AN ACCESSIBLE ROUTE. 11.PARKING SPACES FOR VANS AND ACCESS AISLES AND VEHICULAR ROUTES SERVING THEM SHALL PROVIDE A VERTICAL CLEARANCE OF NINETY-EIGHT (98) INCHES MINIMUM. SIGNS SHALL BE PROVIDED AT ENTRANCES TO PARKING FACILITIES INFORMING DRIVERS OF CLEARANCES AND THE LOCATION OF VAN ACCESSIBLE PARKING SPACES. 12.EACH ACCESSIBLE PARKING SPACE SHALL BE PROVIDED WITH SIGNAGE DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. SIGNS SHALL BE INSTALLED AT A MINIMUM CLEAR HEIGHT OF SIXTY (60) INCHES ABOVE GRADE AND SHALL NOT INTERFERE WITH AN ACCESSIBLE ROUTE FROM AN ACCESS AISLE. SIGNS LOCATED WHERE THEY MAY BE HIT BY VEHICLES BEING PARKED SHALL BE INSTALLED WITH BOLLARD PROTECTION. 13.SIGNAGE AT ACCESSIBLE PARKING SPACES REQUIRED BY THE NC BUILDING CODE SECTION 1106.1SHALL COMPLY WITH THE REQUIREMENTS OF NORTH CAROLINA GENERAL STATUTE 20-37.6 AND 136-30 AND THE NCDOT UNIFORM MANUAL ON TRAFFIC CONTROL DEVICES. A SEPARATE SIGN IS REQUIRED FOR EACH SPACE. SIGNS TO INDICATE THE MAXIMUM PENALTY MUST BE PROVIDED AT EACH ACCESSIBLE SPACE. 14.ACCESSIBLE PARKING SPACE, ACCESS AISLE STRIPING, AND INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE PAINTED BLUE (OR ANOTHER COLOR THAT CAN BE DISTINGUISHED FROM PAVEMENT). PASSENGER LOADING ZONE NOTES: 1.PASSENGER LOADING ZONES SHALL PROVIDE VEHICULAR PULL-UP SPACE NINETY-SIX (96) INCHES WIDE MINIMUM AND TWENTY (20) FEET LONG MINIMUM. 2.PASSENGER LOADING ZONES SHALL PROVIDE A CLEARLY MARKED ACCESS AISLE THAT IS SIXTY (60) INCHES WIDE MINIMUM AND EXTENDS THE FULL LENGTH OF THE VEHICLE PULL-UP SPACE THEY SERVE. 3.ACCESS AISLE SHALL ADJOIN AN ACCESSIBLE ROUTE AND NOT OVERLAP THE VEHICULAR WAY. 4.VEHICLE PULL-UP SPACES AND ACCESS AISLES SERVING THEM SHALL BE LEVEL WITH SURFACE SLOPES NOT EXCEEDING 2.0% IN ALL DIRECTIONS. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE VEHICLE PULL-UP SPACE THEY SERVE. CHANGES IN LEVEL ARE NOT PERMITTED. 5.FLOOR SURFACES OF VEHICLE PULL-UP SPACES AND ACCESS AISLES SERVING THEM SHALL BE STABLE, FIRM AND SLIP RESISTANT. 6. VEHICLE PULL-UP SPACES, ACCESS AISLES SERVING THEM AND A VEHICULAR ROUTE FROM AN ENTRANCE TO THE PASSENGER LOADING ZONE, AND FROM THE PASSENGER LOADING ZONE TO A VEHICULAR EXIT SERVING THEM, SHALL PROVIDE A VERTICAL CLEARANCE OF ONE HUNDRED FOURTEEN (114) INCHES MINIMUM. ACCESSIBLE ENTRANCE NOTES: 1.ACCESSIBLE ENTRANCES SHALL BE PROVIDED AS REQUIRED BY THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS) AND THE NORTH CAROLINA BUILDING CODE, AND APPLICABLE LOCAL LAWS & REGULATIONS. 2.ENTRANCE DOORS, DOORWAYS AND GATES SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS) THE NC BUILDING CODE/ANSI A117.1 AND SHALL BE ON AN ACCESSIBLE ROUTE. TEMPORARY SEEDING GRASS TYPE LBS/ ACRE TIME OF SEEDING FERTILIZER LIMESTONE RYE GRAIN 50 OCT. - APR. 400 LBS/AC. 10-20-20 SWEET SUDAN GRASS 50 JUNE - AUGUST 400 LBS/AC. 10-20-20 GERMAN or BROWNTOP MILLET 50 JUNE - AUGUST 400 LBS/AC. 10-20-20 STRAW MULCH AS NEEDED 4,000 PERMANENT SEEDING GRASS TYPE LBS/ ACRE TIME OF SEEDING FERTILIZER LIMESTONE BERMUDA, HULLED BERMUDA, UNHULLED 10-20 35 MARCH - AUGUST SEPT. - FEB.BY SOIL TEST CENTIPEDE 10 MARCH - AUGUST BY SOIL TEST (NO HIGH PH) TALL FESCUE (COASTAL CULTIVAR RECOMMENDED) 50 MARCH - AUGUST 300 LB/AC 10-20-20 OR BY SOIL TEST SLOPES >= 2:1 CENTIPEDE SERICEA LESPEDEZA 5 20 JAN - DEC BY SOIL TEST EXISTING UTILITY NOTES: 1. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THE ACTUAL LOCATION AND AVAILABILITY OF ALL EXISTING AND PROPOSED UTILITIES IN THE FIELD PRIOR TO GROUND BREAKING. 2. EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND, ARE BASED ON A FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL FIELD VERIFY FIELD CONDITIONS PRIOR TO BEGINNING RELATED CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE IMMEDIATELY. THE CONTRACTOR SHALL RAISE OR LOWER EXISTING MANHOLES AND STRUCTURES TO MATCH FINAL GRADES. 01 / 2 7 / 2 3 01 / 0 1 / 2 3 T I M O T HY G. C L I N K S C A LES 8/7/23 FI N A L D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N 06 / 2 2 / 2 3 10+00 11+00 12+00 13+00 14+00 15+00 0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35 ST A . 1 0 + 5 6 B E G I N RI G H T T U R N L A N E TA P E R ST A . 1 1 + 0 2 BE G I N S O U T H B O U N D WI D E N I N G ST A . 1 1 + 5 6 EN D R I G H T T U R N L A N E TA P E R / B E G I N R I G H T T U R N LA N E E X T E N S I O N ST A . 1 3 + 0 6 EN D R I G H T T U R N L A N E EX T E N S I O N / J O I N E X I S T . RI G H T T U R N L A N E STA. 13+45.22 INTERSECTION OF CAROLINA BEACH ROAD S AND ROAD ASTA. 10+00 INTERSECTION OF CAROLINA BEACH ROAD S AND ANTOINETTE DRIVE TV TV TV BL D G FI R E FI R E FIREFIREFIRE W W W WWWWW W 32 + 0 0 33 + 0 0 33 + 1 1 . 3 5 10+00 11+0011+12.30 11+94.4012+00 12+34.88 13+0013+10.70 13+86.3614+00 14+40.24 15+00 15+40.30 1.7' 32+00 33+00 2 1 . 6 22 . 3 7 2 0 . 4 20 . 8 7 3.00 % 3.84 % TH E T O W N E S A T P A R K P L A C E NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 22321.PE FD C C L L C 12 8 S M A I N S T R E E T , S U I T E 2 SU M M E R V I L L E , S C 2 9 4 8 3 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL CL I E N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 CAROLINA BEACH RD (US HWY 421) SOUTHBOUND PUBLIC R/W VARIES (SPEED LIMIT 45 MPH) 0 25 50 100 200 SCALE: 1"=50' GRAPHIC SCALE FI N A L D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N 60' TO RIGHT TURN ARROW 14 ' STA. 13+06 END RIGHT TURN LANE EXTENTION / JOIN EXIST. RIGHT TURN LANE / END WEDGING STA. 11+02 BEGIN SOUTHBOUND WIDENING / BEGIN WEDGING 5 10 15 25 30 35 20 0 CA R O L I N A B E A C H R D ( U S H W Y 4 2 1 ) GE O M E T R I C & D E M O P L A N VICINITY MAP SCALE: 1" = 1,000' NORTH C A R O L I N A B E A C H R D . CO L L E G E R D . CA R O L I N A B E A C H R D . ANT O I N E T T E D R . SITE 40 C-8.1 1" = 5 0 ' 08 . 1 6 . 2 3 CH B CH B TG C 8/16/23 N O R T H C AROLIN A P R O F E SSION ENGI N E E R SEAL A L T I M O T HY C. C L I N K S C A LES 0 2 8 8 4 7 5 10 15 25 30 35 20 0 40 8" C-900 (DR-18) PVC WATER [PRIVATE] 4" C-900 (DR-18) PVC WATER [PRIVATE] 8" C-900 (DR-18) PVC WATER [PUBLIC] EXISTING 8" WATER MAIN (2) 18" STORM SEWER EXISTING 8" WATER MAIN 10' 30'R30'R SIGHT DISTANCE TRIANGLES TYPICAL STREET INTERSECTION NOT TO SCALE MINIMUM SIGHT TRIANGLE FOR STOP CONDITION WHEN CONNECTING NEW ROADS TO EXISTING STATE MAINTAINED ROADS IS 70 FEET ALONG THE RIGHT OF WAY (ROW) AND 10 FEET ALONG THE NEW RIGHT OF WAY 10'x70' SIGHT TRIANGLE 70' 10'x70' SIGHT TRIANGLE NEW ROAD ROW EX. ROAD ROW LEGEND = ASPHALT OVERLAY = PROPOSED SIGN = RIGHT OF WAY = NEW ASPHALT AREA = PROPOSED STOP SIGN ("R1-1") = APPROX. WEDGING LIMITS NOTES: 1.)SEE SHEET C-8.2 FOR PAVEMENT MARKING LEGEND. 2.)SEE SHEET C-8.2 FOR TYPICAL ROAD SECTIONS 3.)PROPOSED ASPHALT MILL & OVERLAY AREA = 318 SY 4.) NEW ASPHALT AREA = 180 SY 5.) APPROXIMATE WEDGING AREA = 158 SY 6.)CONTRACTOR SHALL RELOCATE EXISTING MAILBOXES AS NECESSARY. 7.)SEE SHEETS C-8.8 THRU C-8.9 FOR TYPICAL DETAILS. AN T O I N E T T E D R . (6 0 ' P U B L I C R / W ) THE TOWNES AT PARK PLACE SUBDIVISION 150' TAPER 150' RIGHT TURN LANE EXTENSION STA. 10+46 BEGIN PAVEMENT MARKINGS - TIE TO EXISTING STA. 11+56 END TAPER / BEGIN RIGHT TURN LANE EXTENSION STA. 10+56 BEGIN TAPER STA. 13+95 TIE TO EXISTING 12 ' 1' 4' 4' 1' ROAD A STA. 32+53.66 PROPERTY LINE (EXIST. NCDOT R/W) APPROXIMATE LIMITS OF PROPOSED WEDGING AS NEEDED TO PROVIDE PROPOSED SLOPE ACROSS EXISTING SHOULDER (TYP.) R31 ' R 3 1 ' APPROXIMATE LIMITS OF PROPOSED MILL & OVERLAY - MILL TO 1.5" DEPTH AND OVERLAY WITH 1.5" S9.5C SURFACE COURSE (TYP.) 11' 26' 11' CL INTERSECTION CAROLINA BEACH RD S STA. 13+45.22 = ROAD A STA. 33+11.35 APPROX. 680 SF EX. GRAVEL DRIVEWAY AND CULVERT TO BE REMOVED STA. 11+74.53, OFFSET 43.63R END WEDGING- TIE TO EXISTING STA. 11+98.10, OFFSET 45.06R END WEDGING- TIE TO EXISTING 12 ' 12 ' APPROX. 89 LF EX. CURB TO BE REMOVED APPROX. 29 SF EX. GRAVEL DRIVEWAY TO BE REMOVED RO A D A (P R I V A T E R / W ) PUBLIC UTILITY EASEMENT 32+00 2 1 . 6 2 0 . 3 10' X 70' SIGHT TRIANGLE (TYP.) EXISTING GRADE (TYP.)EXISTING GRADE (TYP.) PROPOSED GRADE (TYP.) OREILLY AUTOMOTIVE STORES, INC DB 60, PG 332 DB 5606, PG 1079 DB 5948, PG 1485 TYPICAL NCDOT PAVEMENT SECTION ROAD A NOT TO SCALE TYPICAL NCDOT PAVEMENT SECTION CAROLINA BEACH RD S (US HWY 421) NOT TO SCALE CAROLINA BEACH RD (US HWY 421) NORTHBOUND PUBLIC R/W VARIES (SPEED LIMIT 45 MPH) CONTRACTOR SHALL TAP EXISTING 8" WATERMAIN WITH: (1) 8"x8" MJ TEE (CUT IN) 8" MJ SLEEVE, AS REQUIRED (1) 8" MJ GATE VALVE (1) 8"x4" MJ TEE (CUT IN) 8" MJ SLEEVE, AS REQUIRED (1) 4" MJ GATE VALVE EXISTING STORM SEWER = DRIVEWAY REMOVAL AREA 1) R E V I S E D P E R N C D O T R E V I E W C O M M E N T S 08 / 1 5 / 2 3 TV TV TV BL D G LP SIG N FI R E FI R E FIREFIREFIRE W W W WWWWW W FFE 24.85 32 + 0 0 33 + 0 0 33 + 1 1 . 3 5 10+00 11+0011+12.30 11+94.4012+00 12+34.88 13+0013+10.70 13+86.3614+00 14+40.24 15+00 15+40.30 TH E T O W N E S A T P A R K P L A C E NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 22321.PE FD C C L L C 12 8 S M A I N S T R E E T , S U I T E 2 SU M M E R V I L L E , S C 2 9 4 8 3 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL CL I E N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 LEGEND: ASPHALT OVERLAY NEW ASPHALT AREA WEDGING LIMITS RIGHT OF WAY PROPOSED PAVEMENT MARKING SYMBOL NOTES: 1.SNOW PLOWABLE PAVEMENT MARKERS SHALL BE INSTALLED IN ACCORDANCE WITH NCDOT's STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES 2012 AND THE ROADWAY STANDARD DRAWINGS. CURB MOUNTED REFLECTORS ARE TO BE INSTALLED ON TRAFFIC ISLANDS. 2.PAVEMENT MARKINGS SHALL BE THE RESPONSIBILITY OF THE PERMITTEE. THE PERMITTEE SHALL HAVE THE PAVEMENT MARKINGS PRE-MARKED, INSPECTED, AND APPROVED BY NCDOT PERSONNEL PRIOR TO THE PLACEMENT OF FINAL PAVEMENT MARKINGS. CONTACT TRAFFIC SERVICES AT (910)341-0300 FOR PRE-MARKING INSPECTIONS OR FIELD CHANGES. CENTERLINE PAVEMENT MARKINGS SHALL BE INSTALLED THE SAME DAY RESURFACING IS ACCOMPLISHED. ALL OTHER PAVEMENT MARKINGS SHALL BE COMPLETED WITHIN 5 DAYS OF RESURFACING. PAVEMENT MARKINGS SHALL BE THERMOPLASTIC AND MEET THE NCDOT's STANDARD SPECIFICATION FOR ROADS AND STRUCTURES AND NCDOT ROADWAY STANDARD DRAWINGS. 3.WHERE NOT REMOVED BY NEW PAVEMENT, CONFLICTING STRIPING SHALL BE GROUND OFF. MINIMIZE GROOVING OF PAVEMENT DURING SUCH OPERATIONS. 4.NEW ASPHALT AREA = 904 SY 5.PROPOSED ASPHALT OVERLAY AREA = 3,524 SY 6.FOR ALL WORK WITHIN NCDOT RIGHT OF WAY, CONTRACTOR SHALL REFER TO NCDOT STANDARD DRAWINGS, LATEST VERSION, FOR STANDARD DETAILS. SOME OF THESE DETAILS ARE LOCATED ON SHEETS C-9.5 - C-9.7 FOR CONVENIENCE. 7.PAVEMENT MARKINGS SHALL BE IN ACCORDANCE WITH NCDOT STANDARD DRAWINGS 1205.01 AND 1205.04. 8.SITE CONTRACTOR SHALL COORDINATE WITH UTILITY OWNERS FOR ANY TEMPORARY OR PERMANENT UTILITY RELOCATION. 9.SITE CONTRACTOR SHALL COORDINATE WITH WITH OWNERS OF EXISTING MAILBOX'S TO BE RELOCATED. 10.EXISTING DRIVEWAY CULVERTS SHALL BE REMOVED AND REPLACED WHERE SHOWN ON THIS PLAN. COORDINATION NOTES: 1. THE CONTRACTOR IS REQUIRED TO OBTAIN ANY/ALL PERMITS REQUIRED FOR CONSTRUCTION OF THESE PLANS. 2. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH PERMITS ISSUED AND WITH BRUNSWICK COUNTY, NCDOT, AND THE STATE OF NORTH CAROLINA. 3. THE CONTRACTOR IS TO ESTABLISH AND CHECK ALL HORIZONTAL AND VERTICAL CONTROLS TO BE USED WITH THE PROJECT. IN ADDITION, THE CONTRACTOR IS TO COMPUTE THE LAYOUT OF THE ENTIRE SITE PLAN IN ADVANCE OF BEGINNING ANY WORK ASSOCIATED WITH THE SUBJECT PLANS. CONTRACTOR SHALL EMPLOY A PROFESSIONAL SURVEYOR TO PERFORM SITE IMPROVEMENT STAKEOUT(S). 4. ANYTIME WORK IS PERFORMED OFF-SITE OR WITHIN AN EXISTING EASEMENT, THE CONTRACTOR IS TO NOTIFY THE HOLDER OF SAID EASEMENT AS TO THE NATURE OF PROPOSED WORK, AND TO FOLLOW ANY GUIDELINES OR STANDARDS WHICH ARE ASSOCIATED WITH OR REFERENCED IN THE RECORDED EASEMENT. TRAFFIC NOTES: 1. ALL PAVEMENT MARKINGS IN PUBLIC RIGHTS-OF-WAY & FOR DRIVEWAY(S) ARE TO BE THERMOPLASTIC & MEET NCDOT STANDARDS. 2. TRAFFIC CONTROL DEVICES (INCLUDING SIGNS AND PAVEMENT MARKINGS) IN AREAS OPEN TO PUBLIC TRAFFIC ARE TO MEET MUTCD (MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES) STANDARDS. 3. ALL TRAFFIC CONTROL SIGNS AND MARKINGS NOT WITHIN THE PUBLIC RIGHT-OF-WAY ARE TO BE MAINTAINED BY THE PROPERTY OWNER IN ACCORDANCE WITH MUTCD STANDARDS. 4. ANY OPEN CUTTING OF A NCDOT STREET REQUIRES AN ENCROACHMENT PERMIT. IN CERTAIN CASES, AN ENTIRE RESURFACING OF THE AREA BEING OPEN CUT MAY BE REQUIRED. 6. TACTILE WARNING MATS TO BE INSTALLED AT ALL WHEELCHAIR RAMPS. 7.ALL SIGNS AND PAVEMENT MARKINGS IN AREAS OPEN TO PUBLIC TRAFFIC ARE TO MEET MUTCD STANDARDS. 0 20 40 80 160 SCALE: 1"=40' GRAPHIC SCALE FI N A L D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N CA R O L I N A B E A C H R D ( U S H W Y 4 2 1 ) ST R I P I N G P L A N PLAN VIEW (STATION 10+00 - 15+40 SCALE: 1"=40' NCDOT 10'x70' SIGHT DISTANCE TRIANGLE, TYP. VICINITY MAP SCALE: 1" = 1,000' NORTH C A R O L I N A B E A C H R D . CO L L E G E R D . CA R O L I N A B E A C H R D . ANT O I N E T T E D R . SITE PAVEMENT MARKING SCHEDULE FOR US HWY 17/OCEAN HWY E ALL THERMOPLASTIC PAVEMENT MARKINGS SHALL BE 90 MILS THICKNESS. C-8.2 1" = 3 0 ' 08 . 1 6 . 2 3 CH B CH B TG C 8/16/23 N O R T H C AROLIN A P R O F E SSION ENGI N E E R SEAL A L T I M O T HY C. C L I N K S C A LES 0 2 8 8 4 7 EXISTING 8" WATER MAIN 0 15 30 60 120 SCALE: 1"=30' GRAPHIC SCALE 1" = 3 0 ' CAROLINA BEACH RD (US HW Y 4 2 1 ) SOUTHBOUND PUBLIC R/W VA R I E S (SPEED LIMIT 45 MPH) AN T O I N E T T E D R . (6 0 ' P U B L I C R / W ) THE TOWNES AT PARK PLACE SUBDIVISION RO A D A (P R I V A T E R / W ) T71T71 T61 T1 T61 T2 T1 CAROLINA BEACH ROAD S TYP. CROSS SECTION - STA. 12+32 TO STA. 13+06 NOT TO SCALE NOTES -EX. TRAVEL LANES: NO PROPOSED PAVEMENT OR OVERLAY, ONLY MILLING AND RE-STRIPING WHERE NOTED. -EX. PAVED SHOULDERS TO BE MILLED AND WEDGED IN AREA OF WIDENING IN ORDER TO MAINTAIN CROSS-SLOPE AND INTEGRITY OF PAVEMENT SECTION. CONTRACTOR SHALL FIELD VERIFY EX. WIDTH OF PAVED SHOULDERS / WEDGING LIMITS. 0-14'12'+4' EX. DITCH PUBLIC R/W VARIES ℄ EX.SLOPE VARIES~2% SB TRAVEL VARIES EX. PAVEMENT, TYP. EXIST. MONOLITHIC CONCRETE ISLAND, WIDTH VARIES PAVED SHOULDER, TYP. R/W CAROLINA BEACH RD (US HWY 421) NORTHBOUND PUBLIC R/W VARIES (SPEED LIMIT 45 MPH) MATCH EXIST. CROSS-SLOPE SB PROPOSED PAVEMENT, WIDTH VARIES FROM 1-3 FT + 1.5" - S9.5C SURFACE at an average rate of 168 lbs.per sq. yd. 3.0" - I19.0C INTERMEDIATE COURSE at an average rate of 456 lbs. per sq. yd. 5.0" - B25.0C BASE COURSE at an average rate of 342lbs. per sq. yd. MILL TO 1.5" DEPTH AND OVERLAY WITH 1.5" S9.5C SURFACE COURSE at and average rate of 168 lbs. per sq. yd. R/W 12'+12'+ EX. COMPACTED SUBGRADE, TYP VARIES CAROLINA BEACH ROAD S TYP. CROSS SECTION - STA. 10+56 TO STA. 12+32 NOT TO SCALE NOTES -EX. TRAVEL LANES: NO PROPOSED PAVEMENT OR OVERLAY, ONLY MILLING AND RE-STRIPING WHERE NOTED. -EX. PAVED SHOULDERS TO BE MILLED AND WEDGED IN AREA OF WIDENING IN ORDER TO MAINTAIN CROSS-SLOPE AND INTEGRITY OF PAVEMENT SECTION. CONTRACTOR SHALL FIELD VERIFY EX. WIDTH OF PAVED SHOULDERS / WEDGING LIMITS. 0-14'12'+4' EX. DITCH PUBLIC R/W VARIES ℄ EX.SLOPE VARIES~2% SB TRAVEL VARIES EX. PAVEMENT, TYP. EXIST. MONOLITHIC CONCRETE ISLAND, WIDTH VARIES PAVED SHOULDER, TYP. R/W MATCH EXIST. CROSS-SLOPE SB R/W 12'+12'+ EX. COMPACTED SUBGRADE, TYP VARIES PROPOSED PAVEMENT, WIDTH VARIES FROM 1-3 FT + 1.5" - S9.5C SURFACE at an average rate of 168 lbs.per sq. yd. 3.0" - I19.0C INTERMEDIATE COURSE at an average rate of 456 lbs. per sq. yd. 5.0" - B25.0C BASE COURSE at an average rate of 342lbs. per sq. yd. MILL TO 1.5" DEPTH AND OVERLAY WITH 1.5" S9.5C SURFACE COURSE at and average rate of 168 lbs. per sq. yd. 9"X12" CONCRETE CURB PER NCDOT STD. DWGS (SEE DETAIL) ROAD A TYP. CROSS SECTION NOT TO SCALE NOTE: GRADES VARY. SEE GRADING PLAN FOR EXACT ELEVATIONS (TYP.) 1/4" PER FT1/4" PER FT SLOPES= 3:1 6"-AGGREGATE BASE 1/4" PER FT 6" STONE 1.5"-S9.5A SURFACE 1.0' PROPOSED EAST BOUND LANE 12' 26' BC-BC 5' 1.0' 22' EP-EP CURB & GUTTER SPILL 24" VALLEY PROPOSED WEST BOUND LANE 12' 5' SIDEWALK 22.5' 1/4" PER FT 6"STONE ℄ 6" STONE CURB & GUTTER SPILL 24" VALLEY 1.0'1.0' 112' PL PL EXISTING STORM SEWER 1) R E V I S E D P E R N C D O T R E V I E W C O M M E N T S 08 / 1 5 / 2 3 TV TV TV BL D G LP 22 2 2 21 2 1 21 21 21 21 20 20 20 20 20 20 19 19 191919 1918 18 181 8 18 18 18 18 18 17 17 17 17 17 1 6 16 FI R E FI R E FIREFIREFIRE W W W WWWWW W 20 24 24 23 23 23 22 22 2 2 21 21 2120 20 19 19 18 17 171819 (20.33EG) (19.73EG) (19.51EG) (19.33EG) 19.13EP (20.16EG)(19.88EG)(19.60EG)(19.37EG)(19.20EG)(18.99EG) (18.84EG) (18.58EG) (18.49EG)(18.41EG) (18.15EG)(17.99EG)(17.84EG)(17.73EG)(17.68EG) (19.13EG)(x.xxEG)(19.02EG)(18.86EG) (18.63EG)(18.46EG) (18.27EG) (18.21EG)(18.16EG)(18.01EG) (17.90EG) (17.77EG) (17.28EG) (17.30EG) 18.94EP 18.87EP 18.60PG 18.50EP 17.93EP 17.87EP (18.01EG) 17.72EP (17.61EP) JOIN EXIST. CURB 18.42PG 17.95EP 18.57EP JOIN EXIST. CURB 17.93PG 18.12PG (20.38EG) 20.76PG 20.97EP 20.97EP (17.46EG) (18.64EP) LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LO D LO D L O D LODLODLODLODLODLOD LO D LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LO D 10+00 11+0011+12.30 11+94.4012+00 12+34.88 13+0013+10.70 13+86.3614+00 14+40.24 15+00 15+40.30 TH E T O W N E S A T P A R K P L A C E NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 22321.PE FD C C L L C 12 8 S M A I N S T R E E T , S U I T E 2 SU M M E R V I L L E , S C 2 9 4 8 3 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL CL I E N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 CA R O L I N A B E A C H R D ( U S H W Y 4 2 1 ) GR A D I N G , D R A I N A G E , & E C P L A N VICINITY MAP SCALE: 1" = 1,000' NORTH C A R O L I N A B E A C H R D . CO L L E G E R D . CA R O L I N A B E A C H R D . ANT O I N E T T E D R . SITE LEGEND: PROPOSED SPOT ELEVATION PROPOSED LIMITS OF DISTURBANCE PROPOSED SILT FENCE PROPOSED INLET PROTECTION PROPOSED DRAINAGE INLET ASPHALT OVERLAY NEW ASPHALT AREA APPROX. WEDGING LIMITS RIGHT OF WAY LOD GENERAL EROSION AND SEDIMENT CONTROL NOTES (CONT.): 11. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH RUNOFF-PRODUCING EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. 12. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED BY CONTRACTOR ONCE STABILIZATION OR A SUFFICIENT GROUND COVER HAS BEEN ESTABLISHED OR AS DIRECTED BY THE ENGINEER. (NO SEPARATE PAYMENT). NCDENR'S FINAL APPROVAL IS REQUIRED. 13. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE SHALL BE REQUIRED AT ALL CONSTRUCTION STAGING AREA ENTRANCES AND ALL CONSTRUCTION ACCESS LOCATIONS INTO NON-PAVED AREA. (NO SEPARATE PAYMENT). 14. WHEN CROSSING CREEK OR DRAINAGE-WAY, THE DIVISION OF WATER QUALITY SHALL BE CONTACTED PRIOR TO DISTURBING A CREEK. THE CONTRACTOR SHALL INSTALL RIP-RAP WITH FABRIC ALONG DISTURBED BANKS AND CHANNEL AND RESTORE SLOPES TO ORIGINAL CONTOURS, BUT NOT STEEPER THAN 2:1 MAXIMUM. DISTURBED CREEK AREA SHALL BE STABILIZED IMMEDIATELY. MAINTENANCE PLAN: 1.ALL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF- PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS WILL BE MADE IMMEDIATELY TO MAINTAIN ALL PRACTICES AS DESIGNED. 2.ALL CONSTRUCTION ENTRANCES WILL BE PERIODICALLY TOP DRESSED WITH AN ADDITIONAL 2 INCHES OF #4 STONE TO MAINTAIN PROPER DEPTH. ANY SEDIMENT THAT IS TRACKED INTO THE STREET WILL BE IMMEDIATELY REMOVED. 3.SEDIMENT WILL BE REMOVED BEHIND THE SEDIMENT FENCE WHEN IT BECOMES 0.5 FEET DEEP AT THE FENCE. THE SEDIMENT FENCE WILL BE BE REPAIRED AS NECESSARY TO MAINTAIN A BARRIER. SILT FENCE STAKES WILL BE SPACED 6 FEET APART UNLESS A WIRE BACKING IS USED WITH 8 FOOT STAKE SPACING. 4. ALL SEEDED AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED ACCORDING TO SPECIFICATIONS IN THE VEGETATIVE PLAN TO MAINTAIN A VIGOROUS, DENSE VEGETATIVE COVER. 5.INLET PROTECTION - INSPECT WIRE AND ROCK INLET PROTECTION AT LEAST ONCE A WEEK AND AFTER EACH SIGNIFICANT (1 2 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE SEDIMENT STORAGE AREA TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN THE DESIGNATED DISPOSAL AREA AND REPLACE THE CONTAMINATED PART OF THE GRAVEL FACING. EROSION CONTROL AND SEQUENCE OF CONSTRUCTION NOTES: NOTE: THESE EROSION CONTROL AND SEQUENCE OF CONSTRUCTION NOTES ARE INTENDED FOR EACH "PHASE" OF CONSTRUCTION. THE ORDER AND STEPS TAKEN MUST BE IMPLEMENTED AS EACH PART OF THE PROJECT IS DEVELOPED; WHETHER AS A WHOLE OR IN PHASES. ANY EROSION CONTROL DEVICES/MEASURES MUST REMAIN IN PLACE UNTIL ALL DISTURBED AREAS ARE STABILIZED AND ALL IMPROVEMENTS ARE COMPLETE. 1.CONSTRUCT TEMPORARY GRAVEL CONSTRUCTION ENTRANCE(S), ESTABLISH THE LIMITS OF DISTURBANCE, AND TEMPORARY SILT FENCE. 2.CLEAR AND REMOVE FROM SITE ALL TREES (ONLY ONES TO BE REMOVED), ROOTS, ROOT MAT, ETC. FROM THE AREA WITHIN THE DESIGNATED CLEARING LIMITS. 3.INSTALL REMAINING EROSION CONTROL MEASURES AS SHOWN ON THE PLANS WITHIN THE AREA DISTURBED. ALL EROSION CONTROL MEASURES MUST BE INSTALLED BEFORE COMMENCING CONSTRUCTION. 4.PLANT GRASS OVER ALL GRADED AREAS WITHIN 14 WORKING DAYS OF CEASE OF ANY GRADING ACTIVITY. 5.IMMEDIATELY UPON THE INSTALLATION OF ANY STORM DRAINAGE CATCH BASIN, DROP INLET, ETC., THE CONTRACTOR SHALL INSTALL INLET PROTECTION TO STOP ANY SEDIMENT FROM ENTERING THE DRAINAGE SYSTEM. 6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING AND RESTORING TO PRE-CONSTRUTION CONDITIONS ANY AREAS OUTSIDE THE PROJECT LIMITS THAT MAY INADVERTENTLY BE DAMAGED DUE TO THE FAILURE OF THE EROSION CONTROL MEASURES. 7.DURING GRADING AND AFTER GRADING HAS BEEN COMPLETED, THE CONTRACTOR SHALL CONTINUE TO MAINTAIN PERMANENT AND TEMPORARY EROSION CONTROL MEASURES UNTIL FINAL APPROVAL. 8.UPON RECEIVING FINAL APPROVAL, THE CONTRACTOR CAN REMOVE TEMPORARY EROSION CONTROL MEASURES. 9.THE CONTRACTOR SHALL CONTINUE TO WATER, FERTILIZE, MOW AND MAINTAIN SPRIGGED, SODDED, AND PLANTED AREAS UNTIL ALL CONSTRUCTION IS COMPLETE. GENERAL EROSION AND SEDIMENT CONTROL NOTES: 1.THE EROSION CONTROL PLAN SHALL INCLUDE PROVISIONS FOR GROUNDCOVER ON ALL EXPOSED PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES AND ALL SLOPES STEEPER THAN 3:1 WITHIN 7 CALENDAR DAYS FROM THE LAST LAND DISTURBING ACTIVITY. GROUND COVER SHALL BE PROVIDED ON ALL OTHER DISTURBED AREAS WITHIN 14 CALENDAR DAYS FROM THE LAST LAND DISTURBING ACTIVITY. 2.UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CONSTRUCTED AND MAINTAINED IN ACCORDANCE WITH THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL HANDBOOK. (NO SEPARATE PAYMENT). 3.THE CONTRACTOR SHALL NOTIFY PLAN APPROVING AUTHORITY ONE WEEK PRIOR TO THE PRE-CONSTRUCTION CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE WEEK PRIOR TO FINAL INSPECTION. 4.ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO CLEARING AND/OR LAND DISTURBANCE. 5.A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN AND PERMIT SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. 6.PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO OFF-SITE BORROW OR WASTE AREAS STAGING OR STORAGE AREAS), THE CONTRACTOR SHALL PREPARE AND SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND TO THE STATE FOR APPROVAL. CONTRACTOR SHALL PAY ALL FEES REQUIRED AND SHALL INSTALL NECESSARY MEASURES AT NO SEPARATE PAYMENT. THE CONTRACTOR SHALL PROVIDE THE OWNER AND THE ENGINEER A COPY OF THE AMENDED PERMIT. 7. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY EITHER THE REVIEWING AGENCY OR THE ENGINEER. (NO SEPARATE PAYMENT). 8. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION IS ACHIEVED. 9. ALL AREAS DISTURBED BY CONSTRUCTION UNLESS OTHERWISE IMPROVED SHALL BE SODDED OR SEEDED AS INDICATED AND STABILIZED. 10. DURING DEWATERING OPERATIONS, WATER SHALL BE PUMPED INTO AN APPROVED FILTERING DEVICE PRIOR TO DISCHARGE TO RECEIVING OUTLET. Maintenance Seeding Mixture Soil Amendments Seeding Dates Mulch PERMANENT SEEDING SCHEDULE - MIXTURE 5CP Maintenance Seeding dates Soil amendments Mulch TEMPORARY SEEDING-LATE WINTER/EARLY SPRING Seeding Mixture WINTER AND EARLY SPRING SUMMER FALL REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. COASTAL PLAIN - DEC.1-APR. 15 - LATE WINTER AND EARLY SPRING APRIL 15 - AUG. 15 - SUMMER AUG. 15 - DEC. 30 - FALL SPECIES CENTIPEDE GRASS RATE (LB/ACRE) 10-20 MARCH - JUNE APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 300 LB/ACRE 10-10-10 FERTILIZER. DO NOT MULCH. FERTILIZE VERY SPARINGLY--20 LB/ACRE NITROGEN IN SPRING WITH NO PHOSPHORUS. CENTIPEDE GRASS CANNOT TOLERATE HIGH PH OR EXCESS FERTILIZER. SPECIES RYE (GRAIN) ANNUAL LESPEDEZA (KOBE IN PIEDMONT AND COASTAL PLAIN, KOREAN IN MOUNTAINS) 120 50 OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYOND JUNE. SPECIES GERMAN MILLET SPECIES RYE (GRAIN) RATE (LB/ACRE) 40 RATE (LB/ACRE) 120 25.11 NPDES WATER QUALITY STABILIZATION TIME FRAMES SITE AREA DESCRIPTION PERIMETER DIKES, SWALES, DITCHES AND SLOPES STABILIZATION TIMEFRAME EXCEPTIONS HIGH QUALITY WATER (HQW) ZONES SLOPES STEEPER THAN 3:1 SLOPES 3:1 OR FLATTER ALL OTHER AREAS WITH SLOPES FLATTER THAN 4:1 7 DAYS 7 DAYS 7 DAYS 14 DAYS 14 DAYS NONE NONE IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED 7 DAYS FOR SLOPES GREATER THAN 50' IN LENGTH NONE, EXCEPT FOR PERIMETERS AND HQW ZONES NOTATION: DI =DROP INLET CO =CLEANOUT MH =STORM DRAIN MANHOLE EG =EXISTING GRADE PG =PROPOSED GRADE EP =EDGE OF PAVEMENT PLAN VIEW (STATION 10+00-15+40) SCALE: 1"=30' 0 15 30 60 120 SCALE: 1"=30' GRAPHIC SCALE FI N A L D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N EX. ROW LINE, TYP. PROPOSED SILT FENCE (TYP.-SEE DETAIL)CONTRACTOR TO VERIFY LOCATION OF EXISTING WATERLINE AND STORM SEWER PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER IF ANY CONFLICTS C-8.3 1" = 3 0 ' 08 . 1 6 . 2 3 CH B CH B TG C 8/16/23 N O R T H C AROLIN A P R O F E SSION ENGI N E E R SEAL A L T I M O T HY C. C L I N K S C A LES 0 2 8 8 4 7 RO A D A CAROLINA BEACH RD (US HWY 421) NORTHBOUND PUBLIC R/W VARIES (SPEED LIMIT 45 MPH) AN T O I N E T T E D R . (6 0 ' P U B L I C R / W ) EXIST. DRIVEWAY EXIST. DRIVEWAY PROPOSED LIMITS OF DISTURBANCE = 0.25 AC. (TYP.) PROPOSED RIP RAP APRON (TYP.-SEE DETAIL) OREILLY AUTOMOTIVE STORES, INC DB 60, PG 332 DB 5606, PG 1079 DB 5948, PG 1485 RICS5 LLC DB I, PG 9 DB II, PG 43 DB 5305, PG 1058 BENNETT COMMERCIAL PROP, LLC DB I, PG 9 DB 2793, PG 719 THE TOWNES AT PARK PLACE SUBDIVISION CAROLINA BEACH RD (US H W Y 4 2 1 ) SOUTHBOUND PUBLIC R/ W V A R I E S (SPEED LIMIT 45 MPH) 9" X 12" CONCRETE CURB (TYP.-SEE DETAIL) 9" X 12" CONCRETE CURB (TYP.-SEE DETAIL) EXIST. DRIVEWAY 1) R E V I S E D P E R N C D O T R E V I E W C O M M E N T S 08 / 1 5 / 2 3 PERMANENT DRIVEWAY CULVERT [56 LF] (2) 18" RCP CL III (W/ NCDOT PPES) [3.6" FILL AT BOTTOM] DITCH INV.UP(SE)=18.10 DITCH INV.DWN(NW)=16.75 PIPE INV.UP(SE)=17.80 PIPE INV.DWN(NW)=16.45 TV TV TV BL D G BL D G LP LP FI R E FI R E FI R E FIREFIREFIRE W W W W W WWWWW W F M FM CO CO TH E T O W N E S A T P A R K P L A C E NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 22321.PE FD C C L L C 12 8 S M A I N S T R E E T , S U I T E 2 SU M M E R V I L L E , S C 2 9 4 8 3 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL CL I E N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 VICINITY MAP SCALE: 1" = 1,000' NORTH C A R O L I N A B E A C H R D . CO L L E G E R D . CA R O L I N A B E A C H R D . ANT O I N E T T E D R . SITE CA R O L I N A B E A C H R D ( U S H W Y 4 2 1 ) TR A F F I C C O N T R O L P L A N SPECIAL PROVISIONS SEASONAL NIGHT WORK CONDITIONS WILL APPLY. 1.FROM MEMORIAL DAY TO LABOR DAY, NO LANE CLOSURES SHALL TAKE PLACE PRIOR TO 7:00 P.M. AND TRAFFIC SHALL RESUME BEFORE 6:00 A.M. (NIGHT WORK ONLY) (HOURS SUBJECT TO CHANGE DUE TO TRAFFIC CONDITIONS). 2.THE APPLICANT SHALL SUBMIT AN ADEQUATE LIGHTING PLAN TO BE CERTIFIED AND APPROVED BY A NC REGISTERED PROFESSIONAL ENGINEER. 3.AFTER LABOR DAY AND PRIOR TO MEMORIAL DAY, NO LANE CLOSURES SHALL BE APPROVED BETWEEN THE HOURS OF 6:00 A.M. AND 9:00 A.M. AND 4:00 P.M. TO 7:00 P.M. ALONG SR 1100 (RIVER ROAD), (PEAK HOURS-RESTRICTED-HOURS SUBJECT TO CHANGE DUE TO TRAFFIC CONDITIONS). 4.NO LANE CLOSURES SHALL BE ALLOWED ON STATE HOLIDAYS AND LOCAL EVENTS. TRAFFIC CONTROL PLAN 1.BEGINNING WORK AND STREET CLOSING: TRAFFIC CONTROL FOR THIS CONTRACT SHALL BE IN ACCORDANCE WITH THE CURRENT EDITION OF THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES, ALONG WITH THE FOLLOWING SECTION OF THESE SPECIAL PROVISIONS. 2. THE CONTRACTOR IS RESPONSIBLE FOR NOTIFYING THE NCDOT BEFORE ANY ROAD OR LANE CLOSURE. THE CONTRACTOR SHALL CALL THE DISTRICT ENGINEER AT (910) 251-2655 WHEN CLOSING A ROAD OR LANE SO THAT EMERGENCY SERVICES CAN BE NOTIFIED. 3. RIGHT OF WAY USE PERMIT: THE CONTRACTOR WILL NOT BE RESPONSIBLE FOR OBTAINING THE RIGHT-OF-WAY USE PERMIT(S) FROM NCDOT. 4. TRAFFIC CONTROL PLAN: TRAFFIC CONTROL WILL BE PERFORMED BY THE CONTRACTOR BASED ON THE TRAFFIC CONTROL SPECIAL PROVISIONS. THE TRAFFIC CONTROL SPECIAL PROVISIONS MAY REFER TO PLAN SHEET FOR MAJOR WORK ITEMS. THE CONTRACTOR SHALL BE THOROUGHLY FAMILIAR WITH THE CURRENT EDITION OF THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. THE CURRENT EDITION OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION (NCDOT) SUPPLEMENT TO THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS. THE NCDOT ROADWAY STANDARD DRAWINGS, AND THE CURRENT EDITION OF THE NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES. 5. THE CONTRACTOR SHALL MAINTAIN THE TRAFFIC CONTROL AS DESCRIBED HEREIN UNLESS THE CONTRACTOR SUBMITS AN ALTERNATE TRAFFIC CONTROL PLAN TO NCDOT AND IS APPROVED BY NCDOT. NCDOT MAY DIRECT THE CONTRACTOR TO MODIFY TRAFFIC CONTROL, IF IN THE OPINION OF NCDOT, TRAFFIC IS NOT MOVING SAFELY OR EFFICIENTLY. 6. CONSTRUCTION OR MAINTENANCE WORK WHICH INVOLVES CLOSURE OF A LANE OF TRAFFIC WILL NOT BE ALLOWED DURING PEAK FLOW HOURS UNLESS OTHERWISE SPECIFIED IN THE CONTRACT DOCUMENT. 7. THE CONTRACTOR SHALL USE FLAGGER CONTROL AND SHALL MEET IN ACCORDANCE WITH THE LATEST EDITION OF THE MUTCD AND THE NCDOT 2012 STANDARD ROADWAY DRAWINGS AND STANDARD SPECIFICATIONS. IN AREAS OF DROP-OFFS AND LOW SHOULDER THE CONTRACTOR SHALL BACKFILL UP TO THE EDGE AND ELEVATION OF THE EXISTING PAVEMENT. THE CONTRACTOR WILL BE REQUIRED TO MAINTAIN INGRESS AND EGRESS TO ALL BUSINESSES AND DWELLINGS, AND EASY ACCESS TO FIRE HYDRANTS. THE CONTRACTOR SHALL NOT WORK ON BOTH SIDES OF THE ROAD SIMULTANEOUSLY WITHIN THE PROJECT AREA FOR THE DURATION OF THE PROJECT. THE CONTRACTOR SHALL MARK ALL HAZARDS WITHIN THE PROJECT LIMITS WITH WELL-MAINTAINED SIGNS, BARRICADES, WARNING AND/OR CHANNELING DEVICES. 8. THE CONTRACTOR SHALL FURNISH, INSTALL, OPERATE, RELOCATE, MAINTAIN AND REMOVE ALL TEMPORARY TRAFFIC CONTROL DEVICES NECESSARY FOR CONTROLLING TRAFFIC. THE CONTRACTOR SHALL NOTIFY NCDOT REGARDING CONFLICTING PERMANENT SIGNS. ONLY THE NCDOT PERSONNEL SHALL INSTALL, REMOVE OR RELOCATE ANY PERMANENT SIGNS WITHIN THE RIGHT-OF-WAY. ALL CONSTRUCTION SIGNS AND BARRICADES SHALL REMAIN IN PLACE UNTIL THE APPROPRIATE PERMANENT SIGNS AND PAVEMENT MARKINGS ARE INSTALLED. 9. PEDESTRIAN CONSIDERATION: THE CONTRACTOR SHALL REASONABLY ACCOMMODATE THE NEEDS OF ALL PEDESTRIANS. 10. EQUIPMENT AND MATERIAL STORAGE: DURING PERIODS OF CONSTRUCTION INACTIVITY, ALL CONSTRUCTION MATERIALS AND EQUIPMENT SHALL BE STORED BY THE CONTRACTOR AS SPECIFIED IN SECTION XI, PART D OF THE WATCH HANDBOOK. 11. ALL CONCRETE OR PAVED CHANNELIZATION ISLANDS SHALL HAVE A 12 INCH DIAMETER ROUND OR SQUARE SMOOTH WALL HOLE DRILLED, CORED, FORMED OR AIR HAMMERED TO THE SUBGRADE AND BACK FILLED WITH SOIL PLACED A MINIMUM OF 10 FEET FROM THE NOSE OF EACH END OF THE ISLAND (SEE ROADWAY STANDARD Dwg. 904.50), OR AS DIRECTED BY THE ENGINEER. ALL SIGN SUPPORTS THAT ARE TO BE ERECTED IN EITHER EXISTING OR PROPOSED CONCRETE OR PAVED CHANNELIZATION ISLANDS SHALL MEET THE SAME REQUIREMENTS. IF NECESSARY, CONTACT THE TRAFFIC SERVICES UNIT TO MARK CORE LOCATIONS (910-346-2040). LEGEND: ASPHALT OVERLAY NEW ASPHALT AREA RIGHT OF WAY DRUM PLAN VIEW (STATION 10+00 - 15+40) SCALE: 1"=50' 0 25 50 100 200 SCALE: 1"=50' GRAPHIC SCALE FI N A L D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N C-8.4 1" = 5 0 ' 08 . 1 6 . 2 3 CH B CH B TG C 8/16/23 N O R T H C AROLIN A P R O F E SSION ENGI N E E R SEAL A L T I M O T HY C. C L I N K S C A LES 0 2 8 8 4 7 CAROLINA BEACH RD (US H W Y 4 2 1 ) SOUTHBOUND PUBLIC R/W V A R I E S (SPEED LIMIT 45 MPH) AN T O I N E T T E D R . (6 0 ' P U B L I C R / W ) 350' W21-5 48"x48" TRAFFIC DRUM FOR TRAFFIC CONTROL (TYP.) APPROXIMATE LIMITS OF MILL / OVERLAY (TYP.) 100' TAPER EX. EDGE OF PAVEMENT (TYP.) RO A D A (P R I V A T E R / W ) OREILLY AUTOMOTIVE STORES, INC DB 60, PG 332 DB 5606, PG 1079 DB 5948, PG 1485 RICS5 LLC DB I, PG 9 DB II, PG 43 DB 5305, PG 1058 BENNETT COMMERCIAL PROP, LLC DB I, PG 9 DB 2793, PG 719 THE TOWNES AT PARK PLACE SUBDIVISION CAROLINA BEACH RD (US HWY 421) NORTHBOUND PUBLIC R/W VARIES (SPEED LIMIT 45 MPH) 1) R E V I S E D P E R N C D O T R E V I E W C O M M E N T S 08 / 1 5 / 2 3 TV TV TV LP 22 22 22 2 2 2 2 21 2 1 21 21 21 21 21 20 20 20 20 20 20 19 19 191919 1918 18 181 8 18 18 18 18 18 17 17 17 17 17 1 6 16 1 5 1 4 13 12 11 PA R # R 0 7 6 0 0 - 0 0 6 - 0 4 5 - 0 0 0 DB 5 3 0 5 , P G 1 0 5 8 ZO N E D - B - 2 - B U S I N E S S F I R E FI R E FI R E FI R E FIREFIREFIRE W W W W W W W WWWWW W 20 25 24 24 24 24 24 24 23 23 23 2 3 22 22 22 2 2 21 21 2120 20 19 19 18 17 171819 PA R # R 0 7 6 0 0 - 0 0 6 - 0 4 3 - 0 0 0 MA T A V A G A R Y J ET A L DB 5 5 3 1 , P G 2 2 0 0 ZO N E D - B - 2 - B U S I N E S S DI S T R I C T PA R # R 0 7 6 0 0 - 0 0 6 - 0 4 5 - 0 0 0 RI C S 5 L L C DB 5 3 0 5 , P G 1 0 5 8 ZO N E D - B - 2 - B U S I N E S S DI S T R I C T TH E T O W N E S A T P A R K P L A C E NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 22321.PE FD C C L L C 12 8 S M A I N S T R E E T , S U I T E 2 SU M M E R V I L L E , S C 2 9 4 8 3 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL CL I E N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 CAROLINA BEACH RD (US HWY 4 2 1 ) SOUTHBOUND PUBLIC R/W VA R I E S (SPEED LIMIT 45 MPH) 0 15 30 60 120 SCALE: 1"=30' GRAPHIC SCALE FI N A L D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N 14 ' CA R O L I N A B E A C H R D ( U S H W Y 4 2 1 ) NC D O T D R I V E W A Y S I T E P L A N VICINITY MAP SCALE: 1" = 1,000' NORTH C A R O L I N A B E A C H R D . CO L L E G E R D . CA R O L I N A B E A C H R D . ANT O I N E T T E D R . SITE 1" = 5 0 ' 08 . 1 6 . 2 3 DJ L DJ L TG C 8/16/23 N O R T H C AROLIN A P R O F E SSION ENGI N E E R SEAL A L T I M O T HY C. C L I N K S C A LES 0 2 8 8 4 7 EXISTING 8" WATER MAIN AN T O I N E T T E D R . (6 0 ' P U B L I C R / W ) THE TOWNES AT PARK PLACE SUBDIVISION 12 ' 4'4' 26' 12 ' 12 ' R O A D A ( P R I V A T E R / W ) CAROLINA BEACH RD (US HWY 421) NORTHBOUND PUBLIC R/W VARIES (SPEED LIMIT 45 MPH) INTERCHANGE TO SOUTHBOUND CAROLINA BEACH ROAD 1 0 0 ' I N T E R N A L S T E M 114' 30' 28 . 2 ' F R O M RO W T O EX I S T I N G EO P 165.95' FRONTAGE 1) R E V I S E D P E R N C D O T R E V I E W C O M M E N T S 03 / 2 1 / 2 3 OREILLY AUTOMOTIVE STORES, INC DB 60, PG 332 DB 5606, PG 1079 DB 5948, PG 1485 R 3 1 ' R3 1 ' EXISTING STORM SEWER ⅊ ⅊ 77' 152' EXISTING DRIVEWAY (COMMERCIAL USE) EXISTING DRIVEWAY (COMMERCIAL USE) EXISTING DRIVEWAY (COMMERCIAL USE) EXISTING DRIVEWAY (COMMERCIAL USE) 10' X 70' SIGHT TRIANGLE (TYP.) PERMANENT DRIVEWAY CULVERT [56 LF] (2) 18" RCP CL III (W/ NCDOT PPES) [3.6" FILL AT BOTTOM] DITCH INV.UP(SE)=18.10 DITCH INV.DWN(NW)=16.75 PIPE INV.UP(SE)=17.80 PIPE INV.DWN(NW)=16.45 C-8.5 2) R E V I S E D P E R N C D O T R E V I E W C O M M E N T S 08 / 1 5 / 2 3 LEGEND = PROPOSED SIGN = RIGHT OF WAY = PROPOSED STOP SIGN ("R1-1") 1 5 1 4 1 3 1 1 1 0 9 81 2 XXXX XXXXXXX XXXXXXXXXXXXXXX FENCE FENCE FENCE FENCE GRAVEL BRICK APPROXIMATE BLDG L P 2 5 25 25 25 252525 25 25 25 25 25 25 25 20 20 20 20 20 20 2020 2020 2 0 PAR#R07600-006-042-000 MATAVA GARY J ETAL DB 5531, PG 2200 ZONED-R-15-RESIDENTIAL DISTRICT PAR#R07609-007-004-000 BELL SANDRA KAYE DB 9810, PG 1307 ZONED-R-10-RESIDENTIAL DISTRICT PAR#R07609-007-003-000 DUNN RICHARD A DENISE M DB 5552, PG 1007 ZONED-R-10-RESIDENTIAL DISTRICT PAR#R07609-007-002-000 JACKSON KATHLEEN DB 9910, PG 1111 ZONED-R-10-RESIDENTIAL DISTRICT PAR#R07609-007-001-000 SASSER DON W REVOCABLE TR ETAL DB 5131, PG 1996 ZONED-R-10-RESIDENTIAL DISTRICT PAR#R07609-006-001-000 DUNN RICHARD A DENISE M DB 5556, PG 1316ZONED-R-10- RESIDENTIAL DISTRICT PAR#R07610-002-003-000 PEPPER RUBY DB 9909, PG 413 ZONED-R-10-RESIDENTIAL DISTRICT PAR#R07610-002-002-000 STANLEY ALEX T ETAL DB 6122, PG 1198 ZONED-R-10-RESIDENTIAL DISTRICT PAR#R07610-002-001-000 GURGANIOUS SHELVA DEANN DB 1336, PG 1078 ZONED-R-10-RESIDENTIAL DISTRICT FI R E FI R E FI R E FI R E FI R E FI R E W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE 17.5' DRAINAGE EASEMENT 26 26 2 6 26 26 26 2 5 25 2 5 25 2 5 25 25 25 2 5 25 25 25 25 25 25 2 4 24 2 4 24 24 24 24 24 24 24 24 24 24 24 24 24 2 4 24 2424 23 23 23 2323 23 23 22 2120 22 24 24 2 3 2 2 22 21 FFE 25.10 FF E 2 5 . 2 0 FF E 2 5 . 1 0 FF E 2 6 . 5 0 23 SSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS 8+00 9+00 10+00 11+00 12+00 0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40 1.0' 1.5' 2.5' 3' MIN 1.8' 21 . 7 25 . 0 0 24 . 2 24 . 0 0 24 . 7 23 . 7 8 23 . 8 24 . 0 7 2.00% 1.11% LOW POINT STA. = 10+82.12 LOW POINT ELEV. = 23.68 PV C S T A . = 1 0 + 5 0 . 0 0 PV C E L E V . = 2 4 . 0 0 PVI STA. = 10+75.00 PVI ELEV. = 23.50 PV T S T A . = 1 1 + 0 0 . 0 0 PV T E L E V . = 2 3 . 7 8 K = 16' 50' VC 2.08%2.08%0.75% 10 LF CASING PIPE 154 LF OF 8 IN. C-900 PVC (DR-18) @ 0.40% [PUBLIC] 128 LF OF 8 IN. C-900 PVC (DR-18) @ 0.40% [PRIVATE] SS M H E X ST A . = 8 + 5 7 RI M = 2 2 . 0 4 IN V I N = 1 6 . 3 8 ( S S M H - 1 ) IN V O U T = 1 6 . 3 5 SS M H - 1 ST A . = 1 0 + 1 1 RI M = 2 4 . 9 0 IN V I N = 1 7 . 0 0 ( S S M H - 2 ) IN V O U T = 1 7 . 0 0 SS M H - 2 ST A . = 1 1 + 3 9 RI M = 2 3 . 9 2 IN V I N = 1 7 . 5 1 ( S S M H - 3 ) IN V I N = 1 7 . 5 1 ( S S M H - 3 ) IN V I N = 1 7 . 5 1 ( S S M H - 6 ) IN V O U T = 1 7 . 5 1 2.0'2.0' 2.7'2.0' 1.7' 3.7' 2.0' TH E T O W N E S A T P A R K P L A C E NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 22321.PE FD C C L L C 12 8 S M A I N S T R E E T , S U I T E 2 SU M M E R V I L L E , S C 2 9 4 8 3 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL CL I E N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 0 15 30 60 120 SCALE: 1"=30' GRAPHIC SCALE FI N A L D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N 26' AN T O I N E T T E D R I V E ( S R 1 2 4 7 ) NC D O T D R I V E W A Y S I T E P L A N VICINITY MAP SCALE: 1" = 1,000' NORTH C A R O L I N A B E A C H R D . CO L L E G E R D . CA R O L I N A B E A C H R D . ANT O I N E T T E D R . SITE 1" = 5 0 ' 08 . 1 6 . 2 3 DJ L DJ L TG C 8/16/23 N O R T H C AROLIN A P R O F E SSION ENGI N E E R SEAL A L T I M O T HY C. C L I N K S C A LES 0 2 8 8 4 7 ANTOINETTE DR. 60' PUBLIC R/W (25 MPH SPEED LIMIT) THE TOWNES AT PARK PLACE SUBDIVISION 22' RO A D B (P R I V A T E R / W ) 20 ' 63' 1) R E V I S E D P E R N C D O T R E V I E W C O M M E N T S 03 / 2 1 / 2 3 ⅊ 10' X 70' SIGHT TRIANGLE (TYP.) CITY OF WILMINGTON COMMERCIAL DRIVEWAY STANDARD (SEE DETAIL) 20' ⅊ EXISTING DRIVEWAY (RESIDENTIAL USE) EXISTING DRIVEWAY (RESIDENTIAL USE) EXISTING DRIVEWAY (RESIDENTIAL USE) EXISTING DRIVEWAY (RESIDENTIAL USE) 60' 60 ' ROAD A (PRIVATE R/W) 10' 122' PERMANENT ANTOINETTE CULVERT [50 LF] AND CATCH BASIN (1) 18" RCP CL III (W/ NCDOT PPES) [NO FILL IN PIPE] PIPE INV.UP(NE)=19.58 PIPE INV.DWN(SW)=19.45 C-8.6 2) R E V I S E D P E R N C D O T R E V I E W C O M M E N T S 08 / 1 5 / 2 3 EXISTING GRADE (TYP.) PROPOSED GRADE (TYP.) EXISTING 6" WATER MAIN EXISTING 6" GATE VALVE 8" C-900 (DR-18) PVC WATER [PUBLIC] 8" C-900 (DR-18) PVC WATER [PRIVATE] EXISTING 15" STORM SEWER LEGEND = PROPOSED SIGN = RIGHT OF WAY = PROPOSED STOP SIGN ("R1-1") T V XXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXX XXXXXXXXXXXXXXXXXXX T V T V FENCE FENCE BLDG BLDG BLDG L P FENCE FENCE FENCE SH E D SH E D L P L P 30 30 30 30 2 5 25 25 25 2525 25 2 5 25 25 25 25 25 25 252525 25 25 25 25 25 25 25 20 20 20 2 0 20 2 0 20 20 15 FI R E FI R E FI R E FI R E FI R E FI R E W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W FM FM FM FM FM FM FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FIRE FI R E FI R E FI R E W W W W W W W W W W W W W W W FM FM FM FM FM FM FM FM FM FM FM 2 0 323130 29 292828 272727 27 27 26 26 26 26 26 26 2626 26 26 26 26 26 26 26 26 2 6 26 26 26 2 626 26 26 26 26 2 6 26 26 26 2 6 2 6 26 26 26 2 6 2 6 26 25 2525 2 5 252525 2525 2 5 25 2 5 25 25 25 25 25 25 25 25 252525 25 25 2 5 25 25 25 25 25 25 25 25 25 24 24 24 24 2 4 24 24 24 24 24 24 24 24 24 24 24 24 24 24 2424 24 24 24 2 4 24 24 24 2424 24 23 23 23 2 3 23 23 22 22 2 2 22 21 2 1 2 1 2 0 24 24 2 3 2 2 22 21 FFE 25.10 FF E 2 5 . 2 0 FF E 2 5 . 1 0 FF E 2 6 . 5 0 FF E 2 6 . 5 0 FF E 2 6 . 5 0 FF E 2 6 . 5 0 FF E 2 6 . 5 0 FF E 2 6 . 5 0 FF E 2 6 . 5 0 FF E 2 6 . 5 0 FF E 2 5 . 1 0 FF E 2 4 . 8 5 23 SSSSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS 2 0 1 9 1 9 18 1717 18 19 TH E T O W N E S A T P A R K P L A C E NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 22321.PE FD C C L L C 12 8 S M A I N S T R E E T , S U I T E 2 SU M M E R V I L L E , S C 2 9 4 8 3 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL CL I E N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 0 25 50 100 200 SCALE: 1"=50' GRAPHIC SCALE FI N A L D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N NC D O T D R I V E W A Y C U L V E R T DR A I N A G E A R E A S M A P 1" = 5 0 ' 08 . 1 6 . 2 3 DJ L DJ L TG C 8/16/23 N O R T H C AROLIN A P R O F E SSION ENGI N E E R SEAL A L T I M O T HY C. C L I N K S C A LES 0 2 8 8 4 7 THE TOWNES AT PARK PLACE SUBDIVISION RO A D B (P R I V A T E R / W ) ROAD A (PRIVATE R/W) ANTOINETTE DRIVE DRIVEWAY CULVERT DRAINAGE AREA =1.43 AC. CN=71 CAROLINA BEACH ROAD DRIVEWAY CULVERT DRAINAGE AREA =1.38 AC. CN=83 CA R O L I N A B E A C H R D ( U S H W Y 4 2 1 ) PU B L I C R / W V A R I E S (S P E E D L I M I T 4 5 M P H ) ANTOINETTE DR 60' PUBLIC R/W (SPEED LIMIT 25 MPH) C-8.7 1) R E V I S E D P E R N C D O T R E V I E W C O M M E N T S 08 / 1 5 / 2 3 PERMANENT ANTOINETTE CULVERT [50 LF] AND CATCH BASIN (1) 18" RCP CL III (W/ NCDOT PPES) [NO FILL IN PIPE] PIPE INV.UP(NE)=19.58 PIPE INV.DWN(SW)=19.45 PERMANENT DRIVEWAY CULVERT [56 LF] (2) 18" RCP CL III (W/ NCDOT PPES) [3.6" FILL AT BOTTOM] DITCH INV.UP(SE)=18.10 DITCH INV.DWN(NW)=16.75 PIPE INV.UP(SE)=17.80 PIPE INV.DWN(NW)=16.45 ROAD B CULVERT DRAINAGE AREA =1.18 AC. ROAD B OFFSITE DRAINAGE AREA = 0.10 AC. ROAD B OFFSITE DRAINAGE AREA = 0.06 AC. TH E T O W N E S A T P A R K P L A C E NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 22321.PE FD C C L L C 12 8 S M A I N S T R E E T , S U I T E 2 SU M M E R V I L L E , S C 2 9 4 8 3 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL CL I E N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 FI N A L D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N CA R O L I N A B E A C H R D ( U S H W Y 4 2 1 ) DE T A I L S C-8.8 AS N O T E D 08 . 1 6 . 2 3 CH B CH B TG C 8/16/23 N O R T H C AROLIN A P R O F E SSION ENGI N E E R SEAL A L T I M O T HY C. C L I N K S C A LES 0 2 8 8 4 7 1) R E V I S E D P E R N C D O T R E V I E W C O M M E N T S 08 / 1 5 / 2 3 FI N A L D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N TH E T O W N E S A T P A R K P L A C E NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 22321.PE FD C C L L C 12 8 S M A I N S T R E E T , S U I T E 2 SU M M E R V I L L E , S C 2 9 4 8 3 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL CL I E N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 CA R O L I N A B E A C H R D ( U S H W Y 4 2 1 ) DE T A I L S C-8.9 AS N O T E D 08 . 1 6 . 2 3 CH B CH B TG C 8/16/23 N O R T H C AROLIN A P R O F E SSION ENGI N E E R SEAL A L T I M O T HY C. C L I N K S C A LES 0 2 8 8 4 7 METHOD OF TREE PROTECTION DURING CONSTRUCTION NOT TO SCALE NOTE: TREES TO BE SAVED WILL BE CLEARLY MARKED PRIOR TO CONSTRUCTION AND A PROTECTIVE BARRIER IS TO BE INSTALLED AT THE DRIPLINE. DRIP LINE - THE AREA OF SOIL DIRECTLY BENEATH THE TREE EXTENDING OUT TO THE TIPS OF THE OUTERMOST BRANCHES. 3' MIN. STAKE HEIGHT ABOVE GRADE DRIPLINE PROTECTIVE BARRIER EXISTING TREE La, LENGTH W, W I D T H RIP-RAP THICK (t)STORM DRAIN PIPE PLAN FLOW X X X X X X X X X X X X X X X X X X X X X X X X X X NON-WOVEN FILTER FABRIC SECTION STORM DRAIN PIPE TAILWATER SLOPE = 0% PIPE OUTLETS SHALL HAVE FLARED END SECTIONS (UNLESS OTHERWISE INDICATED OR IF PIPES ENTERING PONDS ARE SUBMERGED) NCDOT CLASS B (d50=8") EROSION CONTROL STONE ON A LAYER OF 4" NCDOT #5 OR #57 STONE (t) RIP-RAP APRON DETAIL NOT TO SCALE (GEOTEX 801 OR APPROVED SUBSTITUTE) RIPRAP APRON PIPE DIA. (IN.) LENGTH, La (ft) UPSTREAM WIDTH (FT.) DOWNSTREAM WIDTH, W (FT.) RIP-RAP APRON SCHEDULE STONE THICKNESS t (IN.) DWY CULVERT 9.018 (2)9.013.0 18 STEEP SLOPE MATTING NOT TO SCALE 1.) STEEP SLOPE MATTING REQUIRED ON ALL SLOPES STEEPER THAN 3:1 2.) SLEEP SLOPE MATTING SHALL BE NAGREEN VMAX SC250 OR APPROVED EQUAL. 1) R E V I S E D P E R N C D O T R E V I E W C O M M E N T S 08 / 1 5 / 2 3