Loading...
HomeMy WebLinkAbout1-9-25 PB Agenda PacketNEW HANOVER COUNTY PLANNING BOARD AGENDA Assembly Room, New Hanover County Historic Courthouse 24 North Third Street, Room 301 Wilmington, NC 28401 Members of the Board Jeffrey P Petroff, Chair |Donna Girardot, Vice-Chair Paul Boney|Hansen Ma'hews |Jeffrey Stokley Jr. | H. Allen Pope |Colin J. Tarrant Rebekah Roth, Director| Ken Vafier, Planning Manager JANUARY 9, 2025 6:00 PM Call to Order Pledge of Allegiance Approval of Minutes REGULAR ITEMS OF BUSINESS The Planning Board may consider substanal changes in these peons as a result of objecons, debate, and discussion at the meeng, including rezoning to other classificaons. 1 Preliminary Forum Special Use Permit (S24-04) - Mul<-Family in B-2 - Request by Bayshore Townhomes, LLC, applicant, on behalf of Bee Safe Porters Neck, LLC, property owners, for a special use permit for a 62 unit mul<-family development with 1,800 square feet of of commercial space in a B-2, Regional Business district on a 3.21-acre parcel of land located at 8138 Market Street. Special Use Permit (S24-05) - Addi<onal Dwelling Allowance - Request by Bayshore Townhomes, LLC, applicant, on behalf of Herbert Parham, property owner, for a special use permit for an Addi<onal Dwelling Allowance for 242 row-style dwelling units in an R-15, Residen<al district on a 30.22-acre parcel of land located at the 8100 block of Market Street. Planning Board - January 9, 2025 NEW HANOVER COUNTY PLANNING BOARD REQUEST FOR BOARD ACTION MEETING DATE: 1/9/2025 Regular DEPARTMENT: Planning PRESENTER(S): Robert Farrell, Development Review Supervisor CONTACT(S): Robert Farrell; Rebekah Roth, Planning and Land Use Director SUBJECT: Preliminary Forum Special Use Permit (S24-04) - Mul2-Family in B-2 - Request by Bayshore Townhomes, LLC, applicant, on behalf of Bee Safe Porters Neck, LLC, property owners, for a special use permit for a 62 unit mul2-family development with 1,800 square feet of of commercial space in a B-2, Regional Business district on a 3.21-acre parcel of land located at 8138 Market Street. Special Use Permit (S24-05) - Addi2onal Dwelling Allowance - Request by Bayshore Townhomes, LLC, applicant, on behalf of Herbert Parham, property owner, for a special use permit for an Addi2onal Dwelling Allowance for 242 row-style dwelling units in an R-15, Residen2al district on a 30.22-acre parcel of land located at the 8100 block of Market Street. BRIEF SUMMARY: The applicant has submi ed two special use permits for a mixed use development that encompasses a combined 304 residen&al units and 1,800 square feet of commercial space over five parcels in the Porters Neck area. For the B-2 por&on of the property (3.21 acres), they request an SUP for mul&-family dwellings, proposing 62 units and 1,800 square feet of commercial space. The plan includes a mixed-use building fron&ng Market Street, combining commercial space on the ground floor with residen&al units above, as well as a second building solely for residen&al use. Residen&al development in the B-2 district requires a mixed-use component with pedestrian infrastructure and other requirements. For the R-15 por&on (30.22 acres), the applicants seek an SUP for an Addi&onal Dwelling Allowance to increase the residen&al density to 8.37 units per acre, enabling 242 row-style dwellings. The site plan features an amenity center and residen&al blocks with two-story end units having driveways and no garages, and three-story middle units with ground-floor garages. Requirements for Addi&onal Dwelling Allowances include density maximums, open space, stormwater, access, and proximity to higher-density areas. Due to the interdependence of the two proposals, the applicants have condi&oned the development on the approval of both SUPs. Staff consolidated the projects into one report, with supplemental appendices containing dra; Findings of Fact for each case to be presented to the Board of Commissioners ahead of their February 3 mee&ng. In December 2023 and January 2024, the Board of Commissioners held public hearings regarding rezoning request Z23- 21, which sought to rezone 33.54 acres at 8138 Market Street from B-2 and R-15 to (CZD) RMF-M for the development of 348 row-style dwellings. The applicants withdrew the rezoning request during the January 8 mee&ng, leaving the exis&ng B-2 and R-15 zoning in place. These zoning designa&ons allow various uses by right or with special use permits, avoiding the need for rezoning. Under the current B-2 and R-15 zoning, the site is es&mated to generate approximately 106 AM and 219 PM peak hour Planning Board - January 9, 2025 ITEM: 1 trips. Combined, the sites are es&mated to generate approximately 124 AM and 174 PM peak hour trips resul&ng in an increase of 71 AM trips and decrease in 45 PM trips compared to current zoning. The site is over 100 peak hour threshold that requires a Traffic Impact Analysis (TIA). The full TIA can be viewed online here. The 2016 Comprehensive Plan designates the B-2 por&on of the property as Urban Mixed Use and the R-15 por&on as General Residen&al. Because of the general nature of place type borders, sites located in proximity to the boundaries between place types could be appropriately developed with either place type, allowing site-specific features and evolving development pa erns in the surrounding area to be considered. Urban Mixed Use encourages a blend of residen&al, office, and retail uses at higher densi&es, suppor&ng diverse development such as mixed-use buildings, small-scale commercial, ins&tu&onal, and mul&-family or single-family housing. In contrast, the General Residen&al classifica&on emphasizes lower-density housing, primarily single-family homes or duplexes, with limited commercial uses focused on strategically placed office and retail spaces. It also promotes recrea&onal and school facili&es as integral components of these neighborhoods STRATEGIC PLAN ALIGNMENT: RECOMMENDED MOTION AND REQUESTED ACTIONS: Planning staff and the Planning Board do not make recommenda&ons special use permit requests. As this is a preliminary forum the Planning Board is required to hear the presenta&on of staff, the applicant, and the public to facilitate an open and transparent discussion of the special use permit applica&on. Ques&ons and comments related to the following topics are encouraged: -Components of the proposal that are not clear or where addi&onal informa&on is needed in order to understand the project, -Advice to the applica&on on the presenta&on they will be making to the Board of Commissioners, -Advice to the par&es speaking in opposi&on on what they may want to consider when preparing for the Board of Commissioners mee&ng, and -Advice for both par&es on poten&al issues that should be addressed before the public hearing. ATTACHMENTS: Descrip&on S24-04 & 05 PB Script S24-04 & 05 PB Staff Summary S24-04 & 05 Zoning Map S24-04 & 05 Future Land Use Map S24-04 & 05 Mailout Map S24-04 & 05 Application Cover Sheet S24-04 & 05 Application S24-04 & 05 SUP Narrative S24-04 & 05 Building Elevations S24-04 & 05 TIA Executive Summary S24-04 & 05 TIA Approval Letter Planning Board - January 9, 2025 ITEM: 1 S24-04 & 05 Wetland Determination S24-04 & 05 Site Plan Cover Sheet S24-04 & 05 Site Plans COUNTY MANAGER'S COMMENTS AND RECOMMENDATIONS: (only Manager) Planning Board - January 9, 2025 ITEM: 1 SCRIPT for SPECIAL USE PERMIT Application PRELIMINARY FORUM (S24-04 & 05) Special Use Permit (S24-04 – Bayshore Townhomes Multi-Family in B-2) – Request by Bayshore Townhomes, LLC, applicant, on behalf of Bee Safe Porters Neck, LLC, property owners, for a special use permit for a 62 unit multi-family development with 1,800 square feet of commercial space in a B-2, Regional Business district on a 3.21-acre parcel of land located at 8138 Market Street. Special Use Permit (S24-05 – Bayshore Townhomes Additional Dwelling Allowance) – Request by Bayshore Townhomes, LLC, applicant, on behalf of Herbert Parham, property owner, for a special use permit for an Additional Dwelling Allowance for 242 row-style dwelling units in a R-15, Residential district on a 30.22-acre parcel of land located at the 8100 block of Market Street. 1. This is a Preliminary Forum. The purpose of this forum is to facilitate an open and transparent discussion of the special use permit application and to provide an opportunity for public comments and questions. Please note per state law, the Planning Board will not be making a decision or recommendation this evening. Instead, the decision on the application will be made during the Board of Commissioners’ quasi-judicial hearing, where public participation will be limited to parties with standing and witnesses providing evidence through sworn testimony. Anyone interested in speaking in support or opposition of the project should sign in and speak tonight at this meeting, regardless of standing in the matter. 2. Staff will introduce the application. Then the applicant will be allowed 15 minutes for their presentation. Following the applicant’s presentation, we will have 20 minutes for public questions and comments, and then allow the applicant time to address them. The Board members will then provide their comments and ask questions of the applicant. At the end, Staff will give an overview of next steps in the special use permit process. We will then close the forum. 3. Conduct forum as follows: a. Staff introduction b. Applicant’ s presentation (up to 15 minutes) c. Public comments and questions (up to 20 minutes – total supporters and opponents) d. Applicant response to public comments and questions. e. Planning Board questions and comments regarding the following items: i. Components of the proposal that are not clear or where additional information is needed in order to understand the project, ii. Advice to the applicant on the presentation they will be making at the Board of Commissioners meeting, iii. Advice to parties speaking in opposition on what they may want to consider when preparing for the Board of Commissioners meeting, and iv. Advice for both parties on potential issues that should be addressed prior to the public hearing. f. Staff overview of next steps and the procedures for the Board of Commissioners meeting. 4. Close the Preliminary Forum. Planning Board - January 9, 2025 ITEM: 1 - 1 - 1 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 1 of 21 STAFF SUMMARY FOR S24-04 & S24-05 SPECIAL USE PERMIT APPLICATIONS APPLICATION SUMMARY Case Numbers: S24-04 and S24-05 Requests: S24-04 – Multi-Family in a B-2 District S24-05 – R-15 Additional Dwelling Allowance Applicant: Property Owner(s): Bayshore Townhomes, LLC Bee Safe Porters Neck, LLC and Herbert Parham Location: Acreage: 8138 Market Street and the 8100 block of Market Street 3.21 acres zoned B-2 30.22 acres zoned R-15 33.43 total combined acres PID(s): Comp Plan Place Type: R03600-005-006-002, R03600-005-007-000, R03700-004-147-000, R03700-004-148-000, R03700-004-189-000 Urban Mixed Use and General Residential Existing Land Use: Proposed Land Uses: Vacant Office, Undeveloped Commercial Land, and Forestry Maximum 1,800 square feet of Commercial Maximum 62 Multi-Family Dwelling Units Maximum 242 Row-Style Dwelling Units Current Zoning: B-2, Regional Business and R-15, Residential Planning Board - January 9, 2025 ITEM: 1 - 2 - 1 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 2 of 21 SURROUNDING AREA LAND USE ZONING North Self-Storage, the Harris Teeter Shopping Center, and Porters Pointe Subdivision Open Space B-1, B-2, and R-15 East Single-Family Residential R-15 South Single-Family Residential R-15 West Offices and Light Industrial directly adjacent. Porters Neck Shopping Center (Walmart) and Medical Offices across Market Street I-1 and B-2 ZONING HISTORY June 6, 1971 Initially zoned R-15 (Area 5). December 2, 1985 B-2 portion rezoned for compatibility with an auto parts store in operation at the time (Z-249). January 8, 2024 - Withdrawn In December 2023 and January 2024, the Board of Commissioners held public hearings for rezoning request Z23-21 to rezone 33.54 acres located at 8138 Market Street from B-2 and R-15 to (CZD) RMF-M, Residential Multi-Family – Moderate Density for 348 row-style dwellings. Following board discussion, the applicants withdrew their rezoning request at the January 8, 2024, meeting. Since no action was taken by the board, the existing B-2 and R-15 zoning remained in place. Both districts allow a variety of uses by-right or with approval of a special use permit without the need to change zoning districts. Planning Board - January 9, 2025 ITEM: 1 - 2 - 2 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 3 of 21 COMMUNITY SERVICES Water/Sewer Public water available through CFPUA. Public sewer available through connection to an existing force main. Fire Protection New Hanover County Fire Services, New Hanover County Northern Fire District, New Hanover County Porters Neck Station Schools Porters Neck Elementary, Holly Shelter Middle, and Laney High Schools Recreation Pages Creek Park Reserve and Ogden Park CONSERVATION, HISTORIC, & ARCHAEOLOGICAL RESOURCES Conservation The conservation resource map indicates a natural pond in the easternmost corner of the project area. The pond is below the size required to trigger additional requirements listed in Section 5.7 Conservation Resources. Historic No known historic resources Archaeological No known archaeological resources APPLICANT’S PROPOSED PLANS Combined Site Plans with Staff Markup Multi-Family in B-2 N Additional Dwelling Allowance Planning Board - January 9, 2025 ITEM: 1 - 2 - 3 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 4 of 21 • After withdrawing their rezoning request the applicants revised their previous plan. They have submitted two Special Use Permit applications for different development types allowed under the current zoning designations of the parcels: o The section outlined in Red (left) on the combined plans above is currently zoned B-2. The B-2 district allows residential dwelling units as part of a mixed-used development with approval of a special use permit. o The section outlined in Blue (right) is currently zoned R-15. The R-15 district allows increases to the base density of the district up to 10.2 dwelling units per acre for Additional Dwelling Allowances with approval of a special use permit. • The ordinance requirements for each type of special use permit are different, which requires the two separate special use permit applications. The applicant has proposed conditions that neither project could be developed without approval of both special use permits. • Due to the relationship between the two projects, staff have included both within one staff report. Separate supplemental appendices containing the draft Findings of Fact for each case will be provided to the Board of Commissioners ahead of their February 3 meeting. • Combined, the projects include a total of 1,800 square feet of commercial space and 304 dwelling units consisting of 62 multi-family units and 242 row-style dwellings. • Below is a chart outlining the proposed density of each special use permit and the overall density of the combined project: Project Acres Unit Count Density Multi-Family in a B-2 District 3.21 62 19.3 Additional Dwelling Allowance 30.22 242 8.37 Combined 33.43 304 9.5 Planning Board - January 9, 2025 ITEM: 1 - 2 - 4 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 5 of 21 S24-04 – Multi-Family in a B-2 District Special Use Permit Multi-Family in a B-2 District Site Plan with Staff Markup • For the B-2 portion of the project the applicant is requesting a special use permit for the use of Mult-Family Dwellings in a B-2 District on 3.21 acres. • Section 4.3.2.A.2.B.1 of the Unified Development Ordinance (UDO) states multi-family dwellings in the B-2 district must be part of a mixed-use development established to provide innovative opportunities for an integration of diverse but compatible uses into a single development that is unified by distinguishable design features with amenities and walkways to increase pedestrian activity. • The applicant’s site plan includes 62 multi-family units and 1,800 square feet of commercial space. The building fronting Market Street is proposed as a mixed-use building with commercial space facing Market Street and multi-family dwellings above. The second building is proposed as multi-family units. • The density of the B-2 portion of the project is 19.3 dwelling units per acre. The UDO does not set a prescribed or maximum residential density for mixed-use developments. • The applicant’s project narrative caps the total unit count at 62 but would allow the site to be reconfigured with three buildings instead of two. If approved as part of the special use permit, that change would be allowed administratively by staff. • Multi-family developments in the B-2 district are required to include a mixed-use component that is limited to only uses permitted in the B-1 district. While the TIA analyzed the project as a retail use, other land uses in the B-1 district would be allowed. • Parking is provided throughout the site and is proposed as shared parking between the multi-family dwellings and commercial use. The concept plan also includes the proposed location of exterior light poles. N Multi-Family Multi-Family Access to R-15 Commercial Specimen Trees Planning Board - January 9, 2025 ITEM: 1 - 2 - 5 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 6 of 21 • Sidewalks are provided around the perimeter of both buildings shown on the plan with a sidewalk along the road to access the proposed row-style dwellings on the R-15 portion of the project. • Most of the B-2 project area is within the Special Highway Overlay District (SHOD), which includes a 100-foot setback from the right-of-way and 25-foot side setbacks. Section 4.3.2.A.2.b.8 requires requests for dwellings in the B-2 district provide conceptual elevations showing the proposed architectural style of the buildings which are included below: Mixed-Use Retail and Multi-Family Elevation Planning Board - January 9, 2025 ITEM: 1 - 2 - 6 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 7 of 21 Multi-Family Elevation S24-05 – R-15 Additional Dwelling Allowance Special Use Permit Additional Dwelling Allowance Site Plan with Staff Markup N Access to B-2 Gated Emergency Only Access to Brays Drive Natural Pond Amenity Center Stormwater and Open Space Stormwater and Open Space Planning Board - January 9, 2025 ITEM: 1 - 2 - 7 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 8 of 21 • For the R-15 portion of the project the applicant is requesting a special use permit for an Additional Dwelling Allowance to increase the allowed residential density from 2.5 dwelling units per acre to 8.37 dwelling units per acre for 242 row-style dwelling units on 30.22 acres. • The site plan includes an amenity center and rows of residential units arranged in blocks in the center of the site. The end unit of each row of homes is proposed as two stories with a driveway and no garage. The middle units are three stories with a garage on the ground floor. • The R-15 district establishes a maximum building height of 40 feet but does not restrict the number of stories allowed. The applicant has included a condition restricting the homes to a maximum of three stories, not to exceed 40 feet tall. • The rows of units closest to single-family homes are placed near the existing common areas of the Porters Pointe Subdivision. • The ordinance requires a minimum 35-foot setback around the perimeter of the site. The applicant has included a condition that retains a minimum 35-foot landscape buffer of existing vegetation around the site as a visual buffer. • A road stub is provided to Brays Drive that will be gated for emergency access only. A condition has been included guaranteeing a bicycle and pedestrian connection to Brays Drive. • Additional Dwelling Allowances require a minimum 35% open space and maximum impervious surface limit of 40% of the project acreage. The applicant’s site plan meets those minimum and maximum criteria. • The applicant has included a condition to provide an overland relief path, such as a drainage ditch or swale within a public drainage easement from the natural pond to the stormwater outfall. While not required for Additional Dwelling Allowances, the applicants have included a conceptual elevation of the proposed attached row-style units. Planning Board - January 9, 2025 ITEM: 1 - 2 - 8 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 9 of 21 ZONING CONSIDERATIONS • Multi-Family Dwellings are permitted in the B-2 district with approval of a Special Use Permit and are subject to the requirements in Section 4.3.2.A.2 of the UDO. These standards generally address requirements for mixed-use development, pedestrian infrastructure, use restrictions, shared parking, common areas, and a requirement for building elevations. • Additional Dwelling Allowances are permitted in the R-15 district with approval of a Special Use Permit and are subject to the requirements in Section 3.1.3.E of the UDO. These standards generally address density, open space, utility and stormwater improvements, proximity to higher density place types listed in the Comprehensive Land Use Plan, access, and impervious surface limitations. • As proposed, the Multi-Family in the B-2 portion meets the specifications of Section 4.3.2.A.2 and the Additional Dwelling Allowance for the R-15 portion meets the specifications of Section 3.1.3.E. • If approved, the project would be subject to Technical Review Committee and Zoning Compliance review processes to ensure full compliance with all ordinance requirements and specific conditions included in the approval. Only minor deviations from the approved conceptual plan, as defined by the UDO, would be allowed. Planning Board - January 9, 2025 ITEM: 1 - 2 - 9 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 10 of 21 AREA DEVELOPMENT Planning Board - January 9, 2025 ITEM: 1 - 2 - 10 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 11 of 21 TRANSPORTATION CURRENT CONDITIONS Intensity of Current Zoning Typical development under current zoning would allow a maximum of 75 single-family dwelling units and approximately 22,500 square feet of retail. PROPOSED ACCESS Primary Access Right-in, Right-out access onto Market Street Secondary Access Gated emergency access only onto Brays Drive EXISTING ROADWAY CHARACTERISTICS Affected Roadway Market Street Type of Roadway Principal Arterial Roadway Planning Capacity (AADT) 41,369 Planning Board - January 9, 2025 ITEM: 1 - 2 - 11 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 12 of 21 Latest Traffic Volume (AADT) - 2023 43,000 Latest WMPO Point-in-Time County (DT) 33,524 Current Level of Congestion Above Capacity Sources Source of Planning Capacity: WMPO Source of Latest Traffic Volume: 2023 Source of WMPO Point-in-Time Count: October 2024 NEARBY NCDOT STIP ROADWAY PROJECTS U-4902D – Market Street Improvements (Per NCDOT the Market Street improvements are approximately 77% complete with an estimated completion date of Fall 2025) - Access management improvements from N. College Road to Station Road and from Middle Sound Loop Road to the Mendenhall Drive/Marsh Oaks Drive intersection. - Installation of a center median and pedestrian accessways along Market Street from Middle Sound Loop Road to Marsh Oaks Drive. The pedestrian accessways will consist of a 10-foot-wide multi-use path on the eastern side of the street and a 5-foot wide sidewalk on the western side of the street. - With the widening of Market Street there will be a signalized U-turn with a bulb-out just south of the proposed entrance. TRAFFIC GENERATION Traffic Generation by Present Designation (R-15, 75 du) Traffic Generated by Present Designation (B-2, 22,500 sq ft retail) Traffic Generated by Combined Projects Potential Impact of Proposed Combined Projects AM Peak Hour Trips 53 53 124 +71 PM Peak Hour Trips 71 148 174 -45 Assumptions Typical Development with Existing Zoning – 22,500 square feet of retail and 75 single family dwelling units. Proposed Development – 1,800 square feet of commercial and 304 dwelling units. Sources Source of Trip Generation: ITE Trip Generation Manual, 11th ed TRAFFIC IMPACT ANALYSIS (TIA) The estimated traffic generated from the site is above the 100 peak hour threshold that triggers the ordinance requirement for a Traffic Impact Analysis (TIA). A TIA was previously approved in 2023 for a more intensive development on the site. The applicant’s traffic engineers provided a technical memorandum to the TIA with an updated set of land uses. A team of NCDOT, WMPO, and County planning staff work with an applicant’s traffic engineers to develop the scope for the TIA, including Planning Board - January 9, 2025 ITEM: 1 - 2 - 12 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 13 of 21 the study area, the traffic data which must be collected, trip distribution, and the developments and background traffic growth that must be analyzed. This document is used to identify off-site transportation improvements required to mitigate the impacts of the development and must be approved by the WMPO and NCDOT. Approval Date January 31, 2023 Revised approval December 4, 2024 Development Proposal Analyzed 1,800 square feet of strip retail and 304 multi-family dwelling units. Study Intersections - Market Street and Site Access - Market Street and Cypress Pond Way - Market Street and Hays Lane - Market Street and Porters Neck Road - Porters Neck Road and Brays Drive Trip Generation - 124 AM peak hour trips - 174 PM peak hour trips - 2,330 average daily trips Traffic Data Collection - September 13, 2022 – Market Street at Hays Lane / Commercial Driveway - September 13, 2022 – Market Street at Cypress Pond Way - September 13, 2022 – Market Street at Porters Neck Road - September 13, 2022 – Porters Neck Road at Brays Drive Trip Distribution and Assignment - 60% to and from the south on Market Street - 40% to and from the north on Market Street Planning Board - January 9, 2025 ITEM: 1 - 2 - 13 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 14 of 21 Approved Developments & Background Growth - Marsh Oaks Commercial - Primrose School of Mayfaire - Full Build – 2027 - Growth Rate – 1% per year Required Improvements Market Street and Site Access - Construct a continuous northbound thru-right turn lane on Market Street from the ABC store driveway continuing up to the thru-right lane at the intersection of Market Street and Porters Neck Road. - Construct site access (westbound approach) with one ingress lane and one egress lane, and an internal protected stem of 150 feet, measured from the right- of-way line. - Provide stop control for westbound approach. Market Street and Cypress Pond Way - Install a traffic signal and provide necessary coordination. Market Street and Hays Lane - No improvements required. Market Street and Porters Neck Road - No improvements required. Porters Neck Road and Brays Drive - No improvements required. SUMMARY The project is located along a principal arterial highway that is currently over capacity; however, the Military Cutoff Extension opened in 2024 and is anticipated to reduce traffic congestion in the Porters Neck area. The applicant’s revised TIA includes several roadway improvements including a new right-turn lane on Market Street on a northbound approach to the site and a new traffic signal at Cypress Pond Way. The approved TIA analyzed both full access and gated access onto Brays Drive. The applicants are proposing gated emergency access only onto Brays Drive. Planning Board - January 9, 2025 ITEM: 1 - 2 - 14 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 15 of 21 ENVIRONMENTAL • The property is not within a Natural Heritage Area or the Special Flood Hazard Area. • The property is within the Pages Creek watershed. • The conservation resource map indicates a natural pond in the easternmost corner of the project area. The pond is below the size required to trigger additional requirements listed in Section 5.7 Conservation Resources. • New Hanover County Engineering has identified historic flooding concerns for areas adjacent to the pond including the end of Lantana Lane. The applicant has included a condition to provide an overland relief path, such as a drainage ditch or swale within a public drainage easement from the natural pond to the stormwater outfall. • Per the Classification of Soils in New Hanover County for Septic Tank Suitability, soils on the property consist of Class II (Moderate), Class III (Severe) and Class IV (Unsuitable) soils; however, the project will be served by CFPUA public water and sewer. OTHER CONSIDERATIONS Schools PUBLIC SCHOOL ENROLLMENT ZONES Elementary School Porters Neck Elementary 2024-2025 Capacity 114% Middle School Holly Shelter Middle 2024-2025 Capacity 81% High School Laney High 2024-2025 Capacity 117% STUDENT GENERATION RATES (SGRs) Overall SGR (24-25) 0.19 public school students per residential unit Elementary School SGR (24-25) 0.08 public school students per residential unit Middle School SGR (24-25) 0.04 public school students per residential unit High School SGR (24-25) 0.07 public school students per residential unit Local Elementary SGR (24-25) 0.09 - Higher than the County-Wide Generation Rate SGR Trend (20-21 to 24-25) Decrease of 0.05 public school students per residential unit Planning Board - January 9, 2025 ITEM: 1 - 2 - 15 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 16 of 21 POTENTIAL PROJECT STUDENT IMPACT Intensity of Current Zoning: Typical Development under current zoning would allow a maximum of 75 residential units. Proposed Development: 304 residential units Students Generated by Current Zoning Students Generated by Proposed Zoning Potential Impact of Proposed Project Elementary School 6 24 +18 Middle School 3 12 +9 High School 5 21 +16 TOTAL 14 57 +43 Sources 2024-2025 NHC Student Yield Analysis SUMMARY The proposed project is expected to be completed within five years. Although the public elementary and high schools serving the area are currently over capacity, the development is projected to have minimal impact on school enrollment due to its low student generation rate. Other approved residential developments in the area have either been factored into the student yield analysis or are age-restricted, further limiting additional impact on local schools Planning Board - January 9, 2025 ITEM: 1 - 2 - 16 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 17 of 21 Context and Compatibility • The projects are located in one of the county’s more densely developed corridors and partially within the Porters Neck growth node as identified in the Comprehensive Plan. • The property can only be accessed along Market Street via a right-in/right-out driveway. The Brays Drive connection is proposed for emergency access only. • While the eastern part of the property was zoned for lower density residential development in the early 1970s, both public water and sewer services are now available, which makes this area less likely to be developed for low-density residential. • The site plan places a mixed-use structure closer to Market Street, a largely commercial corridor. This serves as a transition from that corridor to the higher density multi-family building and lower density row-style homes. • Required setbacks and transitional buffers provide additional mitigation for aesthetic effects along the property boundaries. Multi-family residential developments require transitional buffers where the site abuts single-family residential, consisting of vegetation, berms, or fences with vegetation. • The site plan does take into consideration the preservation of large live oak trees on the site, most of which are considered specimen trees. The site plan also does not place development close to the existing pond on site. 2016 COMPREHENSIVE LAND USE PLAN The New Hanover County Future Land Use Map provides a general representation of the vision for New Hanover County’s future land use, as designated by place types describing the character and function of the different types of development that make up the community. These place types are intended to identify general areas for particular development patterns and should not be interpreted as being parcel specific. Future Land Use Map Place Type General Residential and Urban Mixed Use Because of the general nature of place type borders, sites located in proximity to the boundaries between place types could be appropriately developed with either place type, allowing site-specific features and evolving development patterns in the surrounding area to be considered. Planning Board - January 9, 2025 ITEM: 1 - 2 - 17 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 18 of 21 Place Type Description General Residential: Focuses on lower-density housing and associated civic and commercial services. Typically, housing is single-family or duplexes. Commercial uses should be limited to strategically located office and retail spaces, while recreation and school facilities are encouraged throughout. Types of uses include single-family residential, low density multi-family residential, light commercial, civic, and recreational. Urban Mixed Use: Promotes development of a mix of residential, office, and retail uses at higher densities. Types of uses encouraged include office, retail, mixed use, small recreation, commercial, institutional, single-family, and multi-family residential. Analysis The proposed special use permits are located along the Market Street corridor in the Porters Neck area, which is identified as a high growth node in the Comprehensive Plan. Generally, the Comprehensive Plan designates areas along major roadways for higher densities of residential and commercial development. The Urban Mixed Use place type is closer to Market Street, transitioning to General Residential as the property moved away from the higher intensity road corridor. Place type borders are not fixed; however, the intent is for that transitional development pattern between different levels of intensity. In the past, where projects were in more than one place type, densities that are in the range between those two place types have been seen as consistent as long as the development tries to transition or buffer into lower density areas. The Comprehensive Plan classifies the B-2 portion of the site as Urban Mixed Use which promotes multi-family, mixed-use, and higher density single- family development to provide a range of housing types, opportunities and choices. The Urban Mixed Use place type does not recommend a maximum density. R-15 portion of the site is classified as the General Residential place type which focuses on lower-density housing and associated civic and commercial services with a maximum recommended density of 8 dwelling units per acre. The requirements for an Additional Dwelling Allowance require a project to be totally or primarily in, contiguous to, or within 250 feet of, the boundary of areas classified as Employment Center, Urban Mixed Use, or Community Mixed Use place types in the Comprehensive Plan. Additional conditions have been proposed including a requirement that neither project can be completed unless both special use permits are approved, common ownership, buffers, drainage, pedestrian access to Brays Drive, a gated emergency vehicle only access to Brays Drive, tree retention, and building height. Planning Board - January 9, 2025 ITEM: 1 - 2 - 18 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 19 of 21 Proposed Conditions Applicant Proposed Conditions: (additional conditions may be added that will bring the proposal in line with the required conclusions) Multi-Family Dwellings in B-2 Conditions: 1. Any Special Use Permit (“SUP”) pertaining to the subject site (area zoned B-2) shall not be effective without the approval of the separate SUP pertaining to the portion of the overall project currently zoned R-15. 2. Any property currently zoned I-1 is not part of the SUP requests, but the SUP pertaining to the subject site shall not be valid without use of the land zoned I-1 for vehicular, pedestrian, and utility / infrastructure connectivity to the portion of the overall site zoned R-15. 3. The property comprising of the overall project will be combined under common ownership, and the project thereafter will be master planned and developed as such pursuant to the provisions of the subject SUPs. The combined property shall be subjected to the provisions of covenants and restrictions consistent with the conditions imposed by either SUP within the land’s respective zoning. 4. Prior to construction, plans for the project shall clearly identify all access, utility, and stormwater easements between the subject site and through those portions of the property currently zoned I-1 and R-15. 5. Areas of buffer and open space outside of essential site improvements and easements will preserve existing trees that are not dead, dying, or otherwise hazardous. 6. Buildings will be a maximum of three stories and a maximum of 50 feet in height in the B- 2 parcels. Additional Dwelling Allowance in R-15 Conditions: 1. Any Special Use Permit (“SUP”) pertaining to the subject site (area zoned R-15) shall not be effective without the approval of the separate SUP pertaining to the portion of the overall project currently zoned B-2. 2. Any property currently zoned I-1 is not part of the SUP requests, but the SUP pertaining to the subject site shall not be valid without the use of the land zoned I-1 for vehicular, pedestrian, and utility / infrastructure connectivity to the portion of the overall project currently zoned B-2. 3. The property comprising of the overall project will be combined under common ownership, and the project thereafter will be master planned and developed as such pursuant to the provisions of the subject SUPs. The combined property shall be subjected to the provisions of covenants and restrictions consistent with the conditions imposed by either SUP within the land’s respective zoning. 4. Prior to construction, plans for the project shall clearly identify all access, utility, and stormwater easements between the subject site and through those portions of the property currently zoned I-1 and B-2. Planning Board - January 9, 2025 ITEM: 1 - 2 - 19 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 20 of 21 5. Areas of buffer and open space outside of essential site improvements and easements will preserve existing trees that are not dead, dying, or otherwise hazardous. 6. Buildings will be a maximum of three stories and will not exceed 40 feet in height. 7. Access to and from Brays Drive shall be gated and restricted to emergency vehicles only. 8. Buffers between the project and adjacent residential neighborhoods shall exceed minimum requirements. Buffers vary in width. 9. Bicycle and pedestrian infrastructure shall be installed up to the property line where the project road connects to Brays Drive. 10. An overland relief path (swale) within a public drainage easement will be provided from the existing pond to the proposed outfall. Coordination with New Hanover County Engineering will be conducted during the stormwater permitting process for the project in order to determine the specific design of the relief path and easement. Planning Board - January 9, 2025 ITEM: 1 - 2 - 20 S24-04 and S24-05 Staff Summary – Planning Board 1.9.2025 Page 21 of 21 PRELIMINARY FORUM The Planning Board does not make a decision or recommendation on special use permits. The board is requested to hear the presentation of staff, the applicant, and the public to facilitate an open and transparent discussion of the special use permit application. Questions and comments related to the following topics are encouraged: • Components of the proposal that are not clear or where additional information is needed to understand the project, • Advice to the applicant on the presentation they will be giving to the Board of Commissioners, • Advice to the parties speaking in opposition on what they may want to consider when preparing for the Board of Commissioners meeting, and • Advice to both parties on potential issues that should be addressed before the public hearing. Following the Preliminary Forum the special use permits will be scheduled for the February 3 Board of Commissioners meeting for a quasi-judicial hearing. There are four principal conclusions the Board of Commissioners must make when considering a special use permit request based on clear, substantial evidence presented at the hearing. Each special use permit is a distinct request and will require a separate motion from the board: • Conclusion 1: The Board must find that the use will not materially endanger the public health or safety where proposed and developed according to the plan as submitted and approved. • Conclusion 2: The Board must find that the use meets all required conditions and specifications of the Unified Development Ordinance. • Conclusion 3: The Board must find that the use will not substantially injure the value of adjoining or abutting property or that the use is a public necessity. • Conclusion 4: The Board must find that the location and character of the use if developed according to the plan as submitted and approved will be in harmony with the area in which it is to be located and in general conformity with the Comprehensive Land Use Plan for New Hanover County. Planning Board - January 9, 2025 ITEM: 1 - 2 - 21 Planning Board - January 9, 2025 ITEM: 1 - 3 - 1 Planning Board - January 9, 2025 ITEM: 1 - 4 - 1 Planning Board - January 9, 2025 ITEM: 1 - 5 - 1 Initial Application Documents & Materials Planning Board - January 9, 2025 ITEM: 1 - 6 - 1 Planning Board - January 9, 2025 ITEM: 1 - 7 - 1 Planning Board - January 9, 2025 ITEM: 1 - 7 - 2 Planning Board - January 9, 2025 ITEM: 1 - 7 - 3 Planning Board - January 9, 2025 ITEM: 1 - 7 - 4 Planning Board - January 9, 2025 ITEM: 1 - 7 - 5 RCC RCC RCC RCC RCC RCC Planning Board - January 9, 2025 ITEM: 1 - 7 - 6 Planning Board - January 9, 2025 ITEM: 1 - 7 - 7 Page 1 of 8 Special Use Permit Application – Updated 02-2022 NEW HANOVER COUNTY_____________________ DEPARTMENT OF PLANNING & LAND USE 230 Government Center Drive, Suite 110 Wilmington, North Carolina 28403 Telephone (910) 798-7165 FAX (910) 798-7053 planningdevelopment.nhcgov.com SPECIAL USE PERMIT APPLICATION This application form must be completed as part of a special use permit application submitted through the county’s online COAST portal. The main procedural steps in the submittal and review of applications are outlined in the flowchart below. More specific submittal and review requirements, as well as the standards to be applied in reviewing the application, are set out in Section 10.3.5 of the Unified Development Ordinance. *If the proposed use is classified as intensive industry, the applicant shall conduct a community information meeting in accordance with Section 10.2.3, Community Information Meeting. 1. Applicant and Property Owner Information Applicant/Agent Name Owner Name (if different from Applicant/Agent) Company Company/Owner Name 2 Address Address City, State, Zip City, State, Zip Phone Phone Email Email Public Hearing Procedures (Optional) Pre-Application Conference 1* Community Information Meeting 2 Application Submittal & Acceptance 3 Planning Director Review & Staff Report (TRC Optional) 4 Public Hearing Scheduling & Notification 5 Planning Board Preliminary Forum 6 Board of Commissioners Hearing & Decision 7 Post-Decision Limitations and Actions Bayshore Townhomes, LLC 201 N. Elm Street, Suite 201 Greensboro, NC 27401 910-791-6707 (rep) aengebretson@paramounte-eng.com (rep) Herbert E Parham 8304 Bald Eagle Lane Wilmington, NC 28411 Planning Board - January 9, 2025 ITEM: 1 - 7 - 8 Page 2 of 8 Special Use Permit Application – Updated 02-2022 2. Subject Property Information Address/Location Parcel Identification Number(s) Total Parcel(s) Acreage Existing Zoning and Use(s) Future Land Use Classification 3. Proposed Zoning, Use(s), & Narrative Please list the proposed use(s) of the subject property, and provide the purpose of the special use permit and a project narrative (attach additional pages if necessary). 4. Proposed Condition(s) Please note: Within a special use permit proposal, additional conditions and requirements which represent greater restrictions on the development and use of the property than the corresponding zoning district regulations may be added. These conditions may assist in mitigating the impacts the proposed development may have on the surrounding community. Please list any conditions proposed to be included with this special use permit application below. Staff, the Planning Board, and Board of Commissioners may propose additional conditions during the review process that meet or exceed the minimum requirements of the Unified Development Ordinance. R03700-004-147-000;R03700-004-148-000; R03700-004-189-000 +/- 30.22 Acres R-15; Farm General Residential / Porters Neck Growth Node 8100 Block of Market Street *See Attached *See Attached Planning Board - January 9, 2025 ITEM: 1 - 7 - 9 Page 3 of 8 Special Use Permit Application – Updated 02-2022 5. Traffic Impact Please provide the estimated number of trips generated for the proposed use(s) based off the most recent version of the Institute of Traffic Engineers (ITE) Trip Generation Manual. A Traffic Impact Analysis (TIA) must be completed for all proposed developments that generate more than 100 peak hour trips, and the TIA must be included with this application. ITE Land Use: Trip Generation Use and Variable (gross floor area, dwelling units, etc.) AM Peak Hour Trips: PM Peak Hour Trips: 6. Criteria Required for Approval of a Special Use Permit A use designated as a special use in a particular zoning district is a use that may be appropriate in the district, but because of its nature, extent, and external impacts, requires special consideration of its location, design, and methods of operation before it can be deemed appropriate in the district and compatible with its surroundings. The purpose is to establish a uniform mechanism for the review of special uses to ensure they are appropriate for the location and zoning district where they are proposed. For each of the four required conclusions listed below, include or attach a statement that explains how any existing conditions, proposed development features, or other relevant facts would allow the Board of County Commissioners to reach the required conclusion, and attach any additional documents or materials that provide supporting factual evidence. The considerations listed under each required conclusion are simply those suggested to help the applicant understand what may be considered in determining whether a required conclusion can be met. Any additional considerations potentially raised by the proposed use or development should be addressed. 1. The use will not materially endanger the public health or safety if located where proposed and approved. Considerations: • Traffic conditions in the vicinity, including the effect of additional traffic on streets and street intersections, and sight lines at street intersections with curb cuts; • Provision of services and utilities, including sewer, water, electrical, garbage collections, fire protection; • Soil erosion and sedimentation; • Protection of public, community, or private water supplies, including possible adverse effects on surface waters or groundwater; or • Anticipated air discharges, including possible adverse effects on air quality. 129101 LUC 220 252 apartments *See Attached Planning Board - January 9, 2025 ITEM: 1 - 7 - 10 Page 4 of 8 Special Use Permit Application – Updated 02-2022 2. The use meets all required conditions and specifications of the Unified Development Ordinance. 3. The use will not substantially injure the value of adjoining or abutting property, or that the use is a public necessity. Considerations: • The relationship of the proposed use and the character of development to surrounding uses and development, including possible conflicts between them and how these conflicts will be resolved (i.e. buffers, hours of operation, etc.). • Whether the proposed development is so necessary to the public health, safety, and general welfare of the community or County as a whole as to justify it regardless of its impact on the value of adjoining property. *See Attached *See Attached Planning Board - January 9, 2025 ITEM: 1 - 7 - 11 Page 5 of 8 Special Use Permit Application – Updated 02-2022 4. The location and character of the use if developed according to the plan as submitted and approved will be in harmony with the area in which it is to be located and in general conformity with the New Hanover County Comprehensive Land Use Plan. Considerations: • The relationship of the proposed use and the character of development to surrounding uses and development, including possible conflicts between them and how these conflicts will be resolved (i.e. buffers, hours of operation, etc.). • Consistency with the Comprehensive Plan’s goals, objectives for the various planning areas, its definitions of the various land use classifications and activity centers, and its locational standards. *See Attached Planning Board - January 9, 2025 ITEM: 1 - 7 - 12 Page 6 of 8 Special Use Permit Application – Updated 02-2022 Staff will use the following checklist to determine the completeness of your application. Please verify all of the listed items are included and confirm by initialing under “Applicant Initial”. If an item is not applicable, mark as “N/A”. Applications determined to be incomplete must be corrected in order to be processed for further review; Staff will confirm if an application is complete within five business days of submittal. Application Checklist Applicant Initial  This application form, completed and signed  Application fee: • $500; $250 if application pertains to a residential use (i.e., mobile home, duplex, family child care home).  Traffic Impact Analysis (if applicable) • The official TIA approval letter is recommended prior to this item being placed on the Planning Board meeting agenda. • The official TIA approval letter is required prior to this item being placed on the Board of Commissioners meeting agenda.  Conceptual Site Plan including the following minimum elements: • Tract boundaries and total area, location of adjoining parcels and roads • Proposed use of land, structures and other improvements o For residential uses, this shall include number, height, and type of units; area to be occupied by each structure; and/or subdivided boundaries. o For non-residential uses, this shall include approximate square footage and height of each structure, an outline of the area it will occupy, and the specific purposes for which it will be used. • Proposed transportation and parking improvements; including proposed rights-of- way and roadways; proposed access to and from the subject site; arrangement and access provisions for parking areas. • All existing and proposed easements, required setbacks, rights-of-way, and buffering. • The location of Special Flood Hazard Areas. • The approximate location of regulated wetlands. • A narrative of the existing vegetation on the subject site including the approximate location, species, and size (DBH) of regulated trees. For site less than 5 acres, the exact location, species, and sized (DBH) of specimen trees must be included. • Any additional conditions and requirements that represent greater restrictions on development and use of the tract than the corresponding general use district regulations or additional limitations on land that may be regulated by Federal or State law or local ordinance. • Any other information that will facilitate review of the proposed special use permit (Ref. Section 10.3.5, as applicable)  Applications for uses in the intensive industry category must also submit: • Community meeting written summary • A list of any local, state, or federal permits required for use  One (1) hard copy of ALL documents and site plan. Additional hard copies may be required by staff depending on the size of the document/site plan.  One (1) digital PDF copy of ALL documents AND plans  For wireless support structures or substantial modifications, the elements listed on the attached checklist P P P P P P (Approved TIA Provided, Modification to include to decrease residential units & add commercial uses in progress at time of application submittal) N/A N/A RCC RCC RCC RCC RCC RCC Planning Board - January 9, 2025 ITEM: 1 - 7 - 13 Planning Board - January 9, 2025 ITEM: 1 - 7 - 14 Planning Board - January 9, 2025 ITEM: 1 - 7 - 15 Planning Board - January 9, 2025 ITEM: 1 - 7 - 16 Planning Board - January 9, 2025 ITEM: 1 - 7 - 17 Planning Board - January 9, 2025 ITEM: 1 - 7 - 18 Planning Board - January 9, 2025 ITEM: 1 - 7 - 19 Planning Board - January 9, 2025 ITEM: 1 - 7 - 20 Planning Board - January 9, 2025 ITEM: 1 - 7 - 21 Planning Board - January 9, 2025 ITEM: 1 - 7 - 22 Planning Board - January 9, 2025 ITEM: 1 - 7 - 23 Bayshore Townhomes 8100 Block of Market Street SUP Narrative & Supplemental Information Ownership B-2 Parcels: R03600-005-006-002 (± 0.39 AC) R03600-005-007-000 (± 2.82 AC) Owner: Bee Safe Porters Neck LLC 201 North Elm Street, Suite 201 Greensboro, NC 27401 R-15 Parcels: R03700-004-147-000 (± 20.31 AC) R03700-004-148-000 (± 2.12 AC) R03700-004-189-000 (± 7.79 AC) Owner: Herbert E Parham 8304 Bald Eagle Lane Wilmington, NC 28411 Applicant Information Bayshore Townhomes, LLC 201 North Elm Street, Suite 201 Greensboro, NC 27401 Agent Information Shipman & Wright, LLP Gary K. Shipman 575 Military Cutoff Rd, Suire 106 Wilmington, NC 28405 gshipman@shipmanlaw.com 910-762-6752 Paramounte Engineering, Inc. 122 Cinema Drive Wilmington, NC 28403 aengebretson@paramounte-eng.com 910-791-6707 Proposed Zoning, Use(s), & Narrative Please list the proposed use(s) of the subject property and provide the purpose of the special use permit and a project narrative. The Applicant is proposing to construct the “Bayshore Townhomes” project, a development consisting of 304 residential units and up to 1,800 square feet (sf) of commercial space. Located in the 8100 block of Market Steet in Porters Neck, the subject property consists of approximately 33.43 acres (ac) and was previously used as a landscape contracting business and farm/tree nursery. The property is split zoned with the +3.21 ac property area fronting Market Street being zoned B-2 and the remaining +30.22 ac area being zoned R-15. There is approximately 1000 sf of I-1 zoned property (a portion of Parcel R03600-006-082-000) located between the B-2 and R-15 parcels that the applicant is under contract to purchase pending approval of the requested SUPs. This I-1 parcel provides vehicular, Planning Board - January 9, 2025 ITEM: 1 - 8 - 1 pedestrian, and utility/stormwater conveyance between the B-2 and R-15 properties. The I-1 property is not seeking any SUP approval. The I-1 parcel may be allowed access to this project, but no plans are provided herein. Since the zoning regulations applicable to the project vary depending on the subject zoning district, two separate Special Use Permits (SUP) are required. One SUP is required to allow for residential units in the B-2 zoning district, while the second SUP is requested for additional dwelling allowance in the +30.22 ac R-15 zoned property. While two SUPs are required to develop the proposed project, the entire +30.43 ac. property is master planned as a cohesive mixed-use project. Conditions proposed by the applicant within this application request ensure that both SUPs depend on the other to be approved or the project will not move forward as proposed. The entire project will be combined under common ownership and subjected to covenants and restrictions consistent with the conditions imposed by the SUP. In an effort to better explain the project and reduce redundancy, this narrative provides an overview of the master planned development while also providing proposed conditions and criteria responses for each of the specific SUP requests. Zoning Map Project History and Plan Revisions Since the applicant’s previous conditional rezoning development proposal was withdrawn for the subject site in December 2023, we worked with local professionals to refine plans based on the feedback received during the conditional rezoning process. The overall residential units have been reduced by 44 units from 348 units to 304 units. The developer is pursuing a mixed-use SUP on the +3.21 acre B-2 portion of the property to provide a mixture of uses and cluster more of the project density closer to Market Street within the Comprehensive Plan’s Porters Neck Growth Node. This mixed-use development includes no more than 1,800 square feet of commercial and apartments, up to 62 apartment units. In other words, 9% of the site area is now proposed to house 20% of the proposed homes and provides a housing product diversity not previously included in the project. Because the B-2 area apartment units are clustered in fewer buildings than previously proposed, the project now has more usable open space within the B-2 area allowing a fully integrated multi-modal connection to recreation and green space within the B-2 parcels as well as to the more extensive R-15 recreation and open space areas. The remaining +30.43 acre R-15 parcels contain the remainder of the 242 units as rowhouse-style townhomes. The proposed development pattern creates a transition of land uses from the more intense commercial and apartment uses near Market Street to the residential townhomes in the residentially zoned Planning Board - January 9, 2025 ITEM: 1 - 8 - 2 rear portion of the subject property. Wider than required vegetated buffers provide additional protection of views from and to adjacent properties. Additional amenities and stormwater facilities are now better defined and designed. A clubhouse with property management office, community resort-style pool, cabanas, summer kitchen, fitness area, club lounge, and coffee bar provide a central hub for recreation in the community. The interconnected sidewalks down tree-lined streets and wooded nature trails provide pedestrian access from all units to the club amenities as well as other recreation areas, including pickleball courts and an enclosed dog park. As the design of this property progressed, we now have refined engineering design for stormwater facilities and utilities. Building on the comments received during the conditional rezoning meetings and hearings, we now have designed for the drainage swale to allow existing off-site stormwater from neighboring properties to move through the subject site unimpeded and with a more defined outfall. This will promote better drainage of the now affected surrounding properties. Drainage and utility plans illustrating the engineering design elements are included with this application. Current Plans The current SUP proposals create a master planned neighborhood of mixed housing types, amenities, and commercial space. Of the 304 residential units, a maximum of 62 apartments will be constructed in at least two buildings located within the B-2 zoning along Market Street. Because of site’s topography in the location of the commercial use, final design may show a separation of the commercial and residential portions of Building 1. This means the B-2 area would still be mixed use, and would have a maximum of 3 buildings with no change to proposed area/unit caps for either use. The building fronting Market Street is mixed-use and contains no more than 1,800 sf and no less than 1,700 sf of commercial space. The commercial space spans the portion of the building facing Market Street with residential units on the second and third floor of this mixed-use building. All residential-only buildings are proposed with 3 floors of residential units. (The B-2 district allows 3 stories or 50’ height and the R-15 district allows a maximum of 40’ height. All project roads will be privately maintained. The applicant will comply with height and story limits in the respective districts). The mixed-use B-2 development is completely encompassed by sidewalks promoting pedestrian access to and from units to the open spaces under existing specimen live oaks. Seating and multi-use recreation areas as well as landscaping are integrated into the site design promoting views of landscaped greenspace from all units. The remaining 242 residential units located in the R-15 property are two and three story townhomes promoting walking and interaction with neighbors while limiting vehicular /pedestrian conflict through design. We pulled the homes close to the wide, tree-lined sidewalks to create a walkable neighborhood. The rear accessed motor court with surface parking primarily for residents and access to the in-unit garages creates a protected core to each townhome block reducing the pedestrian/vehicular conflicts that occur in most neighborhoods in which homes garages and driveways are front loaded. The curated streetscape links all the units to the central clubhouse and recreation hub of the community as well as the pickleball courts, dog park, playground, wooded trails, and other open space amenities. Parallel parking along the streets provides overflow parking and visitor parking in close proximity to the townhomes. The design provides parking that meets or exceeds the minimum parking requirements as well as the open space requirements. The wide variety of amenities mix passive and active recreation opportunities to encourage a healthy and active community within the neighborhood. In fact, every unit is less than ¼ mile away from multiple open space areas and recreation opportunities. The site is comprised of a mixture of open grassed & wooded areas. Wetlands along the creek are vegetated and will remain undisturbed outside of any wetland impacts permitted for construction of the development’s essential site improvements. Thick wooded areas are both deciduous and evergreen trees and shrubs and exist primarily around the property boundaries and wetlands. Internal portions of the site feature sporadic trees with a managed understory of mowed grassed land. The site design works to wooded areas along property boundaries to the extent possible, but specifically within the R-15 land. The project has wide buffers around the project periphery leaving or augmenting the existing wooded vegetated edge at the property lines. The buffers vary in width, but all exceed the minimum requirement. In addition, the proposed buildings far exceed required setbacks, and increased buffers have been provided along the Planning Board - January 9, 2025 ITEM: 1 - 8 - 3 perimeter of the project to help reduce impacts to adjacent homes. Both the widened buffers and increased setbacks pull the units away from the neighboring properties to protect views. The site design also offers well thought-out infrastructure, including stormwater management both for the proposed neighborhood and for the existing drainage coming onto the site from surrounding properties. During previous planning efforts and community outreach, we heard a variety of concerns about the surrounding lands not draining well. In coordination with NHC Engineering and with additional survey of the property, we propose a drainage swale running from the existing pond on site to the natural outfall, the creek on the southeast of the site. This allows water to better drain, unimpeded, from surrounding properties through this site and to the natural outfall. The existing 404 wetlands will be preserved, outside of a road crossing to access the R-15 land on a road compliant with NHC standards. Proposed stormwater ponds to handle the proposed development are designed to exceed the NHC minimum stormwater requirements, providing additional flood control and promoting responsible development practices for this project and surrounding neighborhoods. The project proposes access from Market Street and to keep through traffic out of adjacent neighborhoods. While there are two existing road stubs to the project, the Porters Crossing road connection on the eastern property boundary stubs into a NHC conservation overlay district (COD). As such, this project leaves the COD intact and avoids making this road connection. The adjacent Porters Pointe neighborhood has a road stub on the northern property boundary at the Brays Drive connection. A secondary access is proposed at this location for emergency-only access. It will have a siren activated, Knox Box, or Knox Lock gate to prevent non-emergency vehicles from traveling through Porters Pointe to Porters Neck Road. The road connection has been previously discussed with New Hanover County Fire Marshal’s office and the design will be further defined and submitted for New Hanover County Planning and Fire Marshal review and approval as part of design development documents for this project. A Traffic Impact Analysis (TIA) was previously approved in 2023 for 348 units on the R-15 portion of the site. The TIA approval letter recommended two major improvements to Market Street: a signalized left turn/U-turn at Cypress Pond Way adjacent to Food Lion, and an extension to the existing right turn lane leading to Porters Neck Road. These improvements exceed those identified by the TIA and not only mitigate project impacts but improve overall performance of the system. The signal will allow enhanced traffic circulation for cars making the left to the Food Lion shopping center or a U-turn to access the Medac or other commercial businesses and professional offices in the area. The extended right turn lane will not only provide right turn lanes for the existing uses between the ABC Store and Porters Neck Road but also a means for vehicles accessing Porters Neck Road to bypass vehicles destined for Hampstead which are waiting for the signal to proceed northward. The TIA modification to reflect the lessened unit count and added commercial retail use is in the process of being reviewed. The modification confirms that the previously required improvements are still appropriate for the revised unit count and commercial space for the overall project. The project offers much needed housing close to goods and services and increases housing stock to lessen our documented housing shortage. Per the City of Wilmington & New Hanover County’s 2022 Housing Needs Assessment Update: “There is an estimated overall housing gap of 12,147 rental units (up from 10,776 units in 2020) and a gap of 16,875 for-sale units (up from 13,017 units in 2020) within the county over the next 10 years. These both represent increases in housing gaps since the 2020 study, with the rental housing gap increasing by 1,371 (12.7%) and the for-sale housing gap increasing by 3,858 (29.6%) over the past two years.” Planning Board - January 9, 2025 ITEM: 1 - 8 - 4 This project has been diligently designed to enhance New Hanover County’s housing offerings while also adding traffic improvements to the Market Street corridor. The design, craftsmanship, materials, and finishes will all be commensurate with New Hanover County’s finest communities and in keeping with the standards the applicant sets as a company. About the Applicant The Applicant is a multifamily development division of The Carroll Companies, and will follow the visions and directives of its President and CEO, Roy E. Carroll, whose achievements and national recognition are directly attributable to the care and attention that he and his companies provide to each project they undertake. The Carroll Companies has developed and continues to develop prestigious properties throughout the Carolinas, and also operates in Tennessee, Texas, Florida, and Montana. The Applicant and The Carroll Companies are looking forward to expanding their presence in New Hanover County, one of North Carolina’s most vibrant areas, as amplified by The Carroll Companies’ “The Avenue” project located on Military Cutoff. The Applicant and The Carroll Companies are sensitive to the concerns regarding the proper development of remaining acreage in New Hanover County, and have designed this project with those concerns in mind. As with all of our projects, quality and protection of the surrounding environment are a cornerstone of this proposed project. B-2 SUP – Residential Units in the B-2 District The following proposed conditions and criteria response relate to the area of the project zoned B-2. Proposed Conditions (B-2) 1. Any Special Use Permit (“SUP”) pertaining to the subject site (area zoned B-2) shall not be effective without the approval of the separate SUP pertaining to the portion of the overall project currently zoned R-15. 2. Any property currently zoned I-1 is not part of the SUP requests, but the SUP pertaining to the subject site shall not be valid without use of the land zoned I-1 for vehicular, pedestrian, and utility/infrastructure connectivity to the portion of the overall project currently zoned R-15. 3. The property comprising of the overall project will be combined under common ownership, and the project thereafter will be master planned and developed as such pursuant to the provisions of the subject Planning Board - January 9, 2025 ITEM: 1 - 8 - 5 SUPs. The combined properties shall be subjected to the provisions of covenants and restrictions consistent with the conditions imposed by either SUP within the land’s respective zoning. 2. Prior to construction, plans for the project shall clearly identify all access, utility, and stormwater easements between the subject site and through those portions of the property currently zoned I-1 and R- 15. 3. Areas of buffer and open space outside of essential site improvements and easements will preserve existing trees that are not dead, dying, or otherwise hazardous. 4. Buildings will be a maximum of three stories and a maximum of 50’ height in the B-2 parcels. Criteria Required for Approval of a Special Use Permit (B-2) 1. The use will not materially endanger the public health or safety if located where proposed and approved. a. The proposal will not materially endanger the public health or safety. The traffic infrastructure required by the approved TIA will be completed prior to project completion and will enhance the safety of this portion of Market Street. b. The stormwater infrastructure that will be installed with development of this project will aid the flow of stormwater through this site, and therefore, away from adjoining properties. c. The proposed development will comply with all local, State, and Federal regulations. d. A Traffic Impact Analysis will be completed for the overall project, and the required roadway improvements will be constructed in accordance with NCDOT standards, and will enhance the safety of this portion of Market Street for traffic going in both directions. e. The project will be served by CFPUA for both water and sewer services. f. Stormwater facilities will be installed in accordance with New Hanover County and State standards. g. The proposed mixed-use commercial and multi-family residential housing is less intense than what could be developed by-right in the B-2 zoning district (gas stations, auto repair, commercial shopping centers, etc.) under the Unified Development Ordinance. h. Soil and erosion control will be designed and permitted in accordance with state and local requirements. The implementation of the design will be monitored by the applicant, applicant’s site contractors, and by regulators to assure compliance with the permit thereby protecting the water supply as well as surface waters. Since this site drains to SA/HWQ waters, erosion control measures will be designed for the 25-year storm event to further protect sensitive waters, additional measures may be employed to assure compliance with the permit. i. The Applicant and Contractor will obtain and comply with all necessary permits and monitor construction activities to avoid possible adverse effects on air quality. 2. The use meets all required conditions and specifications of the Unified Development Ordinance. a. The proposed use will comply with all conditions and specifications of the Unified Development Ordinance, including the specific use standards listed in Section 4.3.2.A.2.b of the code: i. The proposed project will include a mixture of uses that are unified into a single development. ii. The proposed development shall be under single ownership or unified control by the applicant/ a property owners association/ a property management group. iii. The proposed uses within the development shall be restricted to residential uses and commercial uses allowed in the B-1 district. These are less intense uses than the current B-2 zoning allows by-right. iv. Sidewalks will be provided throughout the project and connect to the rear R-15 portion of the master planned project to promote use of project amenities and open space. v. The provided parking shall be shared. All B-2 area uses will provide parking to support the uses on within the B-2 parcels. Planning Board - January 9, 2025 ITEM: 1 - 8 - 6 vi. Community facilities and/or common area will be provided. vii. A mixture of uses with commercial and residential apartments is proposed along Market Street. The proposed commercial space will be located closest to Market Street. viii. Conceptual building elevations have been provided. Exterior lighting shall comply with the standards of the Unified Development Ordinance. 3. The use will not substantially injure the value of adjoining or abutting property, or that the use is a public necessity. a. The proposal will not substantially injure the value of adjoining or abutting property. The applicant will provide an appraiser’s report from a well respected and local MAI appraiser, Brad White, that confirms this. Traffic associated with this use will not travel through any of the adjacent residential subdivisions, and only emergency vehicles will be able to access the adjacent Porters Pointe subdivision through a gate. Great attention has been paid by the applicant to maintain existing vegetative buffers between the project area and the adjacent residential subdivisions. The drainage infrastructure associated with this proposed project will allow water to better drain, unimpeded, from surrounding properties through this site and to the natural outfall. The existing 404 wetlands will be preserved, outside of a road crossing to access the R-15 land on a road compliant with NHC standards. Proposed stormwater ponds to handle the proposed development are designed to exceed the NHC minimum stormwater requirements, providing additional flood control and promoting responsible development practices for this project and surrounding neighborhoods b. The adjacent portion of the Market Street corridor has been developed as a commercial node containing many big box retailers, restaurants, and medical offices. This proposed plan offers a transition of uses from the commercial corridor to multi-family apartments. c. The proposed residential housing is less intense than what could be developed by-right in the B-2 zoning district (gas stations, auto repair, commercial shopping centers, etc.). 4. The location and character of the use if developed according to the plan as submitted and approved will be in harmony with the area in which it is to be located and in general conformity with the New Hanover County Comprehensive Plan. a. The proposal will be in harmony with the area and in general conformity with the New Hanover County Comprehensive Plan. b. The subject site is classified as Urban Mixed Use on the Future Land Use Map included in the 2016 Comprehensive Plan. In addition, the property falls within the Porters Neck Growth Node. c. The Urban Mixed Use classification promotes a mixture of residential, office, and commercial uses at higher densities and intensities. Mixed uses are encouraged on the same parcel in this classification, but they can also be adjacent to each other and separated by roadways in a horizontal pattern. For residential uses, multi-family housing is encouraged, though higher density single-family housing, such as rowhouse/townhouse development, is not prohibited. Urban Mixed Use areas promote the highest densities in the County and are where multi-family housing consistent with the RMF-H zoning district requirements, which allows up to 36 dwellings units per acre, would be most appropriate. The applicant’s proposed B-2 development with a density of 19.31 du/ac is far below the highest allowable densities in Urban Mixed Use areas. d. Growth nodes are areas of concentrated development, having higher intensities and densities than the surrounding area. High-density development is promoted in these areas that will promote pedestrian activity and alternative transportation options. Planning Board - January 9, 2025 ITEM: 1 - 8 - 7 R-15 SUP – Additional Density Allowance The following proposed conditions and criteria response relate to the area of the project zoned R-15. Proposed Conditions (R-15) 1. Any Special Use Permit (“SUP”) pertaining to the subject site (area zoned R-15) shall not be effective without the approval of the separate SUP pertaining to the portion of the overall project currently zoned B-2. 2. Any property currently zoned I-1 is not part of the SUP requests, but the SUP pertaining to the subject site shall not be valid without use of the land zoned I-1 for vehicular, pedestrian, and utility/infrastructure connectivity to the portion of the overall project currently zoned B-2. 3. The property comprising of the overall project will be combined under common ownership, and the project thereafter will be master planned and developed as such pursuant to the provisions of the subject SUPs. The combined properties shall be subjected to the provisions of covenants and restrictions consistent with the conditions imposed by either SUP within the land’s respective zoning. 4. Prior to construction, plans for the project shall clearly identify all access, utility, and stormwater easements between the subject site and through those portions of the property currently zoned I-1 and B- 2. 5. Areas of buffer and open space outside of essential site improvements and easements will preserve existing trees that are not dead, dying, or otherwise hazardous. 6. Buildings will be a maximum of three stories and will not exceed 40’ height 7. Access to and from Brays Drive shall be gated and restricted to emergency vehicles only. 8. Buffers between the project and adjacent residential neighborhoods shall exceed minimum requirements. Buffers vary in width. 9. Bicycle and pedestrian infrastructure shall be installed up to the property line where the project road connects to Brays Drive. 10. An overland relief path (swale) within a public drainage easement will be provided from the existing pond to the proposed outfall. Coordination with NHC Engineering will be conducted during the stormwater permitting process for the project in order to determine the specific design of the relief path and easement. Criteria Required for Approval of a Special Use Permit (R-15) 1. The use will not materially endanger the public health or safety if located where proposed and approved. a. The proposal will not materially endanger the public health or safety. The traffic infrastructure that will be completed will enhance the safety of this portion of Market Street. Approved Traffic Impact Analysis will dictate the improvements required for the developer to install and they will be installed prior to completion of construction. b. The stormwater infrastructure that will be installed will aid the flow of stormwater through this site, and therefore, away from adjoining properties. c. The proposed development will comply with all local, State, and Federal regulations. d. The project will be served by CFPUA for both water and sewer services. e. Stormwater facilities will be installed in accordance with New Hanover County and State standards. f. A overland relief path within a public drainage easement will be provided from the existing pond to the proposed outfall. g. Soil and erosion control will be designed and permitted in accordance with state and local requirements. The implementation of the design will be monitored by the applicant, applicant’s site contractors, and by regulators to assure compliance with the permit thereby protecting the water supply as well as surface waters. Since this site drains to SA/HWQ waters, erosion control measures will be designed for the 25-year storm event to further protect sensitive waters, additional measures may be employed to assure compliance with the permit. Planning Board - January 9, 2025 ITEM: 1 - 8 - 8 h. The Applicant and Contractor will obtain and comply with all necessary permits and monitor construction activities to avoid possible adverse effects on air quality. 2. The use meets all required conditions and specifications of the Unified Development Ordinance. a. The proposed use will comply with all conditions and specifications of the Unified Development Ordinance, including the specific use standards listed in Section 3.1.3.E of the code. Per this UDO section: i. The proposed use complies with the maximum density standard of 10.2 du/ac permitted with the Additional Dwelling Allowance in the R-15 zoning district. ii. No AE or VE floodplain impacts will occur with this project since it is located in Zone X. iii. The subject site is contiguous to a Urban Mixed Use Place Type. The site is also part of the Land Use Plan’s Identified Growth Node for Porters Neck. The proposed use has direct access to and from an existing major arterial street (Market Street)The proposed use provides a minimum of 35% open space and includes constructed recreation amenities throughout the proposed development. iv. The proposed use will connect to public water and sewer and comply with all regulatory standards of the UDO and state and local permits v. The proposed use will not exceed a maximum of 40% impervious surfaces on the property. vi. The proposed use shall comply with all applicable setback, parking, and landscaping requirements. No structure will exceed 40’ height, the maximum dictated for the R-15 district by the UDO. 3. The use will not substantially injure the value of adjoining or abutting property, or that the use is a public necessity. a. The proposal will not substantially injure the value of adjoining or abutting property. The applicant will provide an Affidavit from a well-respected and local MAI appraiser that confirms this. Traffic associated with this use will not travel through any of the adjacent residential subdivisions, and only emergency vehicles will be able to access the adjacent Porters Pointe subdivision through a gate. Great attention has been paid by the applicant to maintain existing vegetative buffers between the project area and the adjacent residential subdivisions. The drainage infrastructure associated with this proposed project will allow water to better drain, unimpeded, from surrounding properties through this site and to the natural outfall. The existing 404 wetlands will be preserved, outside of a road crossing to access the R-15 land on a road compliant with NHC standards. Proposed stormwater ponds to handle the proposed development are designed to exceed the NHC minimum stormwater requirements, providing additional flood control and promoting responsible development practices for this project and surrounding neighborhoods b. The adjacent portion of the Market Street corridor has been developed as a commercial node containing many big box retailers, restaurants, and medical offices. c. Buffers beyond minimum requirement in width and vegetation density will be provided along adjacent residential homes. The location of existing site features such as existing ditches and pond help assure additional setback of structures, protect views for adjacent properties, and promote clustering the housing farther from the property line than is required. d. The proposed plan transitions uses from commercial along Market Street to multi-family apartments to townhomes. e. Because proposed uses are similar to those of surrounding properties, hours of operations and activities are compatible. f. Housing in all product types is a documented need according to the City/New Hanover County joint housing study. This project promotes complementary commercial and residential uses located next to each other all while offering a diversity of housing types near the goods and services of the Porters Neck Growth Node. Planning Board - January 9, 2025 ITEM: 1 - 8 - 9 g. Access will be provided only from Market Street and not through adjacent neighborhoods (except for emergency vehicles on Brays Drive). 4. The location and character of the use if developed according to the plan as submitted and approved will be in harmony with the area in which it is to be located and in general conformity with the New Hanover County Comprehensive Plan. a. The proposal will be in harmony with the area and in general conformity with the New Hanover County Comprehensive Plan. b. The proposed development offers a transition of residential housing types between Market Street and existing R-15 development. Townhomes are appropriate in the General Residential classifications and help achieve Goal XV of the Comprehensive Plan that encourages the development of a range and diversity of housing types. c. The proposed density of 8.37 du/ac excluding the conservation overlay district and density of 8.0 du/ac including the conservation overlay district in the density calculation reflects compliance with both the UDO and County’s Comprehensive Plan. The project offers an appropriate blend of the recommendations of the General Residential place type and the Porters Neck Growth Node. d. The subject site is classified as Urban Mixed Use on the Future Land Use Map included in the 2016 Comprehensive Plan. In addition, the property falls within the Porters Neck Growth Node. e. The Comprehensive Plan supports increased density in Growth Nodes (Goal III) f. Growth nodes are areas of concentrated development, having higher intensities and densities than the surrounding area. High-density development is promoted in these areas that will promote pedestrian activity and alternative transportation options. g. By transitioning the uses within the project from commercial along the Market Street commercial corridor to multi-family apartments to townhomes to open space and stormwater adjacent to the surrounding residential neighborhoods, this project steps down proposed land use intensities. Contrary to the development patterns of traditional single-family neighborhoods found throughout the County in which land is allowed to be cleared to the property line with little to no buffers required, this proposed in-fill project carefully balances the clustering of density away from property lines and exceeds minimum County requirements to provide and enhance the existing vegetated buffers to protect the character and development pattern surrounding the site. Planning Board - January 9, 2025 ITEM: 1 - 8 - 10 Planning Board - January 9, 2025 ITEM: 1 - 9 - 1 Planning Board - January 9, 2025 ITEM: 1 - 9 - 2 Planning Board - January 9, 2025 ITEM: 1 - 9 - 3 TR A N S P O R T A T I O N PROJECT # Celebr atin gCelebrating Market Street Townhomes Wilmington, NC PREPARED FOR: CIP Construction Company December 2, 2022 220248 Planning Board - January 9, 2025 ITEM: 1 - 10 - 1 Planning Board - January 9, 2025 ITEM: 1 - 10 - 2 12/2/2022 220248 Market Street Townhomes i EXECUTIVE SUMMARY The proposed residential development is located east of Market Street and south of the intersection of Brays Drive and Shackleford Drive in Wilmington, NC. The proposed development is planned to consist of up to 348 townhomes. The expected build-out year for this development is 2024. Information regarding this property was provided by CIP Construction Company. Two scenarios were analyzed for this Transportation Impact Analysis (TIA). Scenario A analyzed two access points for the development. The first access point, which is right-in/right-out (RIRO), will be located along Market Street approximately 325 feet south of Cypress Pond Way. The second access point will be a new connection extending Brays Drive. In Scenario B, only the first access point along Market Street will be used, while the access point to Brays Drive will be used for emergency access only. DAVENPORT was retained to determine the potential traffic impacts of this development and to identify transportation improvements that may be required to accommodate the impacts of the new development traffic. The TIA was performed based on the scope agreed upon with the Wilmington Metropolitan Planning Organization (WMPO) and the North Carolina Department of Transportation (NCDOT). This site has a trip generation potential of 2,306 daily trips, 131 trips in the AM peak hour, and 170 trips in the PM peak hour. Based on the capacity analysis, recommendations have been given where necessary to mitigate the impacts of future traffic. Improvements are summarized in Table A and Figure A. In conclusion, this study has determined the potential traffic impacts of this development. Recommendations have been given to accommodate these impacts. The analysis indicates that with the recommended improvements in place, the proposed site is not expected to have a detrimental effect on transportation capacity and mobility in the study area. The recommendations in Figure A and in Table A should be constructed to comply with applicable NCDOT Policy on Street and Driveway Access to North Carolina Highways and local standards. Planning Board - January 9, 2025 ITEM: 1 - 10 - 3 12/2/2022 220248 Market Street Townhomes ii Table 6.1 – Summary of Recommended Improvements INTERSECTION SCENARIO A RECOMMENDATIONS (2 Access Points) SCENARIO B RECOMMENDATIONS (1 Access Point) Market Street and Hays Lane/ Commercial Driveway No improvements recommended No improvements recommended Market Street and Cypress Pond Way Extend northbound left turn lane storage by 50 feet to 300 feet with appropriate taper. Extend northbound left turn lane storage by 50 feet to 300 feet with appropriate taper. Market Street and Porters Neck Road No improvements recommended No improvements recommended Porters Neck and Brays Drive (Site Access 2) No improvements recommended No improvements recommended Market Street and Site Access 1 Install northbound right turn lane with 150 feet of storage and appropriate deceleration and taper Design site drive according to applicable NCDOT and local standards. Install northbound right turn lane with 200 feet of storage and appropriate deceleration and taper Design site drive according to applicable NCDOT and local standards. Planning Board - January 9, 2025 ITEM: 1 - 10 - 4 Planning Board - January 9, 2025 ITEM: 1 - 10 - 5 Page 2 11/18/2024 Market Street Townhomes DAVENPORT Project No. 220248 2 Table 1- ITE Trip Generation: Updated Land Use Average Weekday Driveway Volumes Daily AM Peak Hour PM Peak Hour Land Use ITE Land Code Size Data Source Total Enter Exit Total Enter Exit Total Multifamily Housing (Low- Rise) 220 304 Dwelling Units Adjacent - Equation 2,024 28 89 117 95 56 151 Strip Retail 822 1.8 KSF Adjacent - Equation 306 6 3 9 12 11 23 Total Unadjusted Trips 2,330 34 92 126 107 67 174 Internal Capture Reduction** Internal Capture %- 1.6%0.0% LUC 822 - -1 0 -1 0 0 0 LUC 220 - 0 -1 -1 0 0 0 Total Internal Capture Trips --1 -1 -2 0 0 0 Total Adjusted Trips 2,330 33 91 124 107 67 174 Table 2- ITE Trip Generation- Approved TIA Average Weekday Driveway Volumes Daily AM Peak Hour PM Peak Hour Land Use ITE Land Code Size Data Source Total Enter Exit Total Enter Exit Total Multifamily Housing (Low- Rise) 220 348 Dwelling Units Adjacent - Equation 2,306 31 100 131 107 63 170 Total Trips in Approved TIA 2,306 31 100 131 107 63 170 Table 3- ITE Trip Generation Comparison Table Average Weekday Driveway Volumes Daily AM Peak Hour PM Peak Hour Total Enter Exit Total Enter Exit Total Updated Proposed Land Use (Adjusted Trips)2,330 33 91 124 107 67 174 Approved TIA Total Trips 2,306 31 100 131 107 63 170 Difference (Updated Minus Previous)24 2 -9 -7 0 4 4 5.0 Market Street Traffic Volumes Turning movement counts utilized in the approved TIA were collected by Quality Counts when schools were in session. Table 4 contains the location, dates, and times these counts were conducted. Traffic count data are provided in the Appendix. In conducting the future no build and future build analysis, a 1% growth rate was applied to these volumes. Planning Board - January 9, 2025 ITEM: 1 - 10 - 6 Page 3 11/18/2024 Market Street Townhomes DAVENPORT Project No. 220248 3 Table 4 - Traffic Volume Data Count Location Date Taken Hours Market Street at Hays Lane / Commercial Driveway 9/13/2022 Quality Counts Market Street at Cypress Pond Way 9/13/2022 Quality Counts Market Street at Porters Neck Road 9/13/2022 Quality Counts Porters Neck Road at Brays Drive 9/13/2022 Quality Counts The North Carolina Department of Transportation completed the Military Cutoff Road extension project in September 2023. The Military Cutoff Road extension provides a bypass to Market Street for vehicles traveling to/from locations north of the I-140 ramp on Market Street to south of Military Cutoff Road. As the study intersections above are located within the portion of Market Street encompassed by this bypass, data indicates volumes along Market Street dropped since the initial counts taken in 2022. While new counts have not been collected at the study intersections above, DAVENPORT has counts on file for a nearby project at the intersection of Market Street and Wendover Lane, south of this proposed development. Counts at Market Street and Wendover Lane were collected in September 2021 (pre–Military Cutoff Extension opening) and December 2023 (post Military Cutoff Extension opening). Figures 1A and 1B provide the through volumes on Market Street north of Wendover Lane for the two collection dates. The volumes above equate to a 36% and 21% reduction in through volumes on Market Street in the AM and PM peak hours, respectively. As mentioned above, traffic counts utilized in the TIA were taken prior to the opening of the Military Cutoff Extension and a 1% growth rate was applied to these volumes in the TIA. The data supporting that there has been a drop in volumes on Market Street since the opening of the Military Cutoff Extension makes the analysis in the approved TIA inherently conservative. Figure 1A: 2021 Peak Hour Volumes Figure 1B: 2023 Peak Hour Volumes Planning Board - January 9, 2025 ITEM: 1 - 10 - 7 Page 4 11/18/2024 Market Street Townhomes DAVENPORT Project No. 220248 4 6.0 Site Access Scenarios As previously mentioned, the TIA presented two access scenarios: One with a single right-in right- out access located on Market Street and a second scenario with the right-in right-out on Market Street and a secondary access as a proposed extension to Brays Drive. The updated site plan proposes to have the secondary Brays Drive gated emergency only access, all site traffic will utilize the Market Street access. The analysis in the TIA indicated there is a minimal impact to delay and queues between the two different access scenarios. Based upon the NCDOT turn lane nomograph, there was a difference (150 feet vs 200 feet) in right-turn lane length recommended at the proposed Market Street site access in the TIA. The TIA approval letter required right turn lane mitigation beyond what was recommended in the TIA. Due to the negligible differential in performance, mitigation above the requirement for both scenarios and commentary from the Bray’s Drive residents who maintain the private roadway, DAVENPORT recommends that Bray’s Drive be provided as emergency only access. 7.0 Conclusion In conclusion, this memorandum compares the updated land use trip generation with the trip generation utilized in the January 2023 approved TIA. It has determined that there is an increase of twenty-four (24) daily trips, a decrease in seven (7) AM peak hour trips, and an increase in four (4) PM peak hour trips. The increase as a function of the updated land use is not significant. Additionally, the approved TIA analysis is conservative considering there has been a reduction in traffic volumes on Market Street from what was analyzed in the approved TIA. Considering this information, we respectfully request an extension to the TIA approval letter dated January 31, 2023 to an anticipated 2027 build year and a definitive recommendation for which access scenario is required. The improvements outlined in the TIA approval letter are acknowledged and accepted with no modifications requested. Please let us know if you need additional information. Planning Board - January 9, 2025 ITEM: 1 - 10 - 8 December 4, 2024 Mr. A. J. Anastopoulo, P.E DAVENPORT 5917 Oleander Drive, Suite 206 Wilmington, NC 28403 RE: REVISED Approval with conditions of the Traffic Impact Analysis (TIA) for the proposed Market Street Townhome Apartments development in New Hanover County, NC Dear Mr. Anastopoulo: The WMPO, NCDOT, and New Hanover County staffs have reviewed the Market Street Townhome Apartments TIA (sealed December 2, 2022) and Trip Comparison Memorandum (prepared by Davenport and sealed November 18, 2024). Based on the information provided and conversations held to date, it is our understanding that the proposed development has a build out year of 2027 2024 and will consist of: o ITE Land Use Code 220 – 304 DU up to 348 DU Multi-family (low-rise) residential o ITE Land Use Code 822 – 1,800 SF Strip Retail Plaza (<40 KSF) Two access scenarios were evaluated. Both Scenario A and Scenario B are viable access options as evaluated in the Transportation Impact Analysis (TIA). o Scenario A provides two access points: one at US 17 Business (Market Street) and one extending Brays Drive as a full-access connection. This configuration offers additional system-wide operational benefits by integrating the new development with the existing roadway network, facilitating connectivity with another neighborhood, and improving access to other system roadways. o Scenario B limits access to a single point at US 17 Business (Market Street), with Brays Drive serving as emergency access only. While this approach meets access and safety requirements, it lacks the broader connectivity and operational advantages of Scenario A. Based on the TIA, either scenario is acceptable from a traffic operations standpoint, and both satisfy the requirements for mitigating the development’s traffic impacts. However, the additional connectivity and operational benefits offered by Scenario A make it the preferred option for optimizing long-term network performance. Planning Board - January 9, 2025 ITEM: 1 - 11 - 1 Revised approval with conditions of Market Street Townhome Apartments (TIA) Page 2 of 3 The following improvements are required of the developer: US 17 (Market Street) and Hays Lane/Commercial Driveway (Signalized intersection) • No improvements are required. US 17 (Market Street) and Cypress Pond Way (Unsignalized left over) • Install a traffic signal and provide necessary coordination. US 17 (Market Street) and SR 1402 (Porters Neck Road) (Signalized intersection) • No improvements are required. SR 1402 (Porters Neck Road) and Brays Drive/Site Access 2 (Stop-controlled intersection) • No improvements are required. US 17 (Market Street) and Site Access 1 (Stop-controlled right-in/right-out intersection) • Construct a continuous northbound thru-right turn lane on US 17 (Market Street) from ABC store driveway continuing up to the thru-right lane at the intersection of US 17 (Market Street) and Porters Neck Road. • Construct site access (westbound approach) with one ingress lane and one egress lane, and an internal protected stem of 150 feet, measured from the right-of-way line. • Provide stop control for westbound approach. If changes are made to the proposed site driveways and/or land uses, the current trip distribution may need to be modified and would require a revised Traffic Impact Analysis to be submitted for review by the NCDOT, WMPO, and New Hanover County, in which instance this approval would become null and void. The applicant is required to obtain all applicable New Hanover County and NCDOT permits for access to the road network. A copy of this TIA approval shall be included with any NCDOT driveway permit application. All applicable NCDOT and New Hanover County technical standards and policies shall apply. Please contact me at (910) 341-7890 if you have any questions regarding this approval. Sincerely, Abby Lorenzo, MPA Deputy Director Wilmington Urban Area MPO Ec: Ben Hughes, PE, District Engineer, NCDOT Jon Roan, Deputy District Engineer, NCDOT Frank Mike, Assistant District Engineer, NCDOT Stonewall Mathis, PE, Division Traffic Engineer, NCDOT Planning Board - January 9, 2025 ITEM: 1 - 11 - 2 Revised approval with conditions of Market Street Townhome Apartments (TIA) Page 3 of 3 Bryce Cox, Senior Assistant Traffic Engineer, NCDOT Madi Lee, PE, Development Review Engineer, NCDOT Ken Vafier, Planning Manager, New Hanover County Robert Farrell, Senior Planner, New Hanover County Planning Board - January 9, 2025 ITEM: 1 - 11 - 3 DEPARTMENT OF THE ARMY U.S. ARMY CORPS OF ENGINEERS, WILMINGTON DISTRICT WILMINGTON REGULATORY OFFICE 69 DARLINGTON AVENUE WILMINGTON NORTH CAROLINA 28403 August 26, 2024 Regulatory Program/Division Sent Via Email: rcarroll@thecarrollcompanies.com Roy Carroll Bee Safe Portersneck LLC PO Box 9846 Greensboro, NC 27429 Dear Mr. Carroll: This letter is in response to your request to the Wilmington District, Wilmington Regulatory Field Office for an approved jurisdictional determination. The project/review area is located at Latitude 34.294690 and Longitude -77.789260; in Porters Neck, New Hanover County, North Carolina. The review area for this determination is limited to an approximately 33.7 acre(s) which is illustrated on the enclosed site maps. This request has been assigned the file number SAW-2024-01415 (Market Street Townhomes). This file number should be referenced in all correspondence concerning this project. Based on our review of the information you furnished, a site inspection conducted on August 15, 2024, and other information available to our office, we have determined the above-referenced area contains 1.3 acre(s) of wetland waters of the United States (U.S.) and 2,405 linear feet of Non-wetland Waters of the U.S. under U.S. Army Corps of Engineers (Corps) regulatory jurisdiction. The site also contains 1.3 acers of excluded non jurisdictional open water pond area. These waters are identified in the enclosed site maps and Post USACE Sketch dated August 15, 2024. This determination was made in accordance with the Corps regulatory authority pursuant to Section 404 of the Clean Water Act, and based upon criteria contained in the 1987 Corps of Engineers Wetland Delineation Manual and the Atlantic and Gulf Coastal Plain regional supplement. This determination is valid for a period of five years from the date of the letter, unless new information warrants revision of the determination before the expiration date or a District Engineer has identified, after public notice and comment, that specific geographic areas with rapidly changing environmental conditions merit re-verification on a more frequent basis. This letter contains an approved jurisdictional determination for your subject site. If you object to this determination, you may request an administrative appeal under Corps regulations at 33 CFR Part 331. Enclosed you will find a Notification of Appeal Process (NAP) fact sheet and request for appeal (RFA) form. If you request to appeal this determination you must submit a completed RFA form to the Division Appeals Officer at Planning Board - January 9, 2025 ITEM: 1 - 12 - 1 the address listed on the RFA form. In order for an RFA to be accepted by the Corps, the Corps must determine that it is complete, that it meets the criteria for appeal under 33 CFR part 331.5, and that it has been received by the Division Office within 60 days of the date of the NAP. Should you decide to submit an RFA form, it must be received by the Corps by October 20, 2024. It is not necessary to submit an RFA form to the Division Office if you do not object to the determination in this correspondence. Section 404 of the Clean Water Act requires a Department of the Army (DA) permit be obtained prior to the discharge of dredged or fill material into waters of the United States, including wetlands. Section 10 of the Rivers and Harbors Act of 1899 requires a DA permit be obtained for any work in, on, over or under navigable waters of the United States. This determination has been conducted to identify the limits of Corps’ Clean Water Act jurisdiction for the review area identified in this request. The determination may not be valid for the wetland conservation provisions of the Food Security Act of 1985. If you or your tenant are USDA Program participants, or anticipate participation in USDA programs, you should request a certified wetland determination from the local office of the Natural Resources Conservation Service, prior to starting work. You are cautioned that work performed below the mean high-water line or ordinary high water line in waters of the United States; and/or, the discharge of dredged or fill material into any areas identified on the enclosed information as within Federal jurisdiction, without a Department of the Army permit could subject you to enforcement action. Receipt of a permit from a state or local municipality does not obviate the requirement for obtaining a Department of the Army permit. If you have any questions concerning this correspondence, please contact Brad Shaver, Project Manager of the Wilmington Regulatory Field Office at 910-251-4611, by mail at the above address, or by email at brad.e.shaver@usace.army.mil. Please take a moment to complete our customer satisfaction survey located at https://regulatory.ops.usace.army.mil/customer-service-survey/. Sincerely, Brad Shaver Project Manager Enclosures cc: Mark Westendorff, Davey Resource Group (via mark.westendorff@davey.com) Herbert Parham (my hep@yahoo.com) Kim Williams, DRG Brad Shaver Digitally signed by Brad Shaver Date: 2024.08.26 09:54:07 -04'00' Planning Board - January 9, 2025 ITEM: 1 - 12 - 2 R R RR b10 a20 a10 DP2 Up DP1 Up DP2 Wet DP1 Wet c1 tt pl b1 tt pl a1 tt pl c10 tt pl b25 tt pl a31 tt pl T2 T1 T3 W2 W1 ExP1 NOTE: This is not a survey. All boundaries and distances are considered approximate. This represents a preliminary sketch prepared from field notes.A survey of delineated areas and review and approval by the U.S. Army Corps of Engineers is recommended prior to specific site planning. 3805 Wrightsville AvenueWilmington, NC 28403(910) 452-0001 Post USACE OnsiteSection 404/401Preliminary WetlandDelineation Sketch L:\WETLANDS\2024 WETLANDS FILES\P.ENV0002402 --- 24 - Market St Townhomes, CIP\MAPSBoundaries are approximate and not meant to be absolute. Map Source: 2020 NC OneMap Scale applies to 11X17" print. Market St. TownhomesNew Hanover County, NC Map Date: Updated August 15, 2024 P.ENV0002402 0 250 500125Feet¯ Legend Project Area ~33.7 Acres Uplands ~31.1 Acres (92%) Wetland Waters of the US ~1.3 Acres (4%) Non-Jurisdictional Pond (Excluded) ~1.3 Acres (4%) Non-wetland Waters of the US (Tributary) ~2,405 lf R Data Points Planning Board - January 9, 2025 ITEM: 1 - 12 - 3 -1- NOTIFICATION OF ADMINISTRATIVE APPEAL OPTIONS AND PROCESS AND REQUEST FOR APPEAL Applicant: Roy Carroll, Bee Safe Portersneck LLC File Number: SAW-2024-01415 Date: 8/26/2024 Attached is: See Section below ܆ INITIAL PROFFERED PERMIT (Standard Permit or Letter of permission) A ܆ PROFFERED PERMIT (Standard Permit or Letter of permission) B ܆ PERMIT DENIAL WITHOUT PREJUDICE C ܆ PERMIT DENIAL WITH PREJUDICE D ܈ APPROVED JURISDICTIONAL DETERMINATION E ܆ PRELIMINARY JURISDICTIONAL DETERMINATION F SECTION I The following identifies your rights and options regarding an administrative appeal of the above decision. Additional information may be found at https://www.usace.army.mil/Missions/Civil-Works/Regulatory- Program-and-Permits/appeals/ or Corps regulations at 33 CFR Part 331. A: INITIAL PROFFERED PERMIT: You may accept or object to the permit x ACCEPT: If you received a Standard Permit, you may sign the permit document and return it to the district engineer for final authorization. If you received a Letter of Permission (LOP), you may accept the LOP and your work is authorized. Your signature on the Standard Permit or acceptance of the LOP means that you accept the permit in its entirety, and waive all rights to appeal the permit, including its terms and conditions, and approved jurisdictional determinations associated with the permit. x OBJECT: If you object to the permit (Standard or LOP) because of certain terms and conditions therein, you may request that the permit be modified accordingly. You must complete Section II of this form and return the form to the district engineer. Upon receipt of your letter, the district engineer will evaluate your objections and may: (a) modify the permit to address all of your concerns, (b) modify the permit to address some of your objections, or (c) not modify the permit having determined that the permit should be issued as previously written. After evaluating your objections, the district engineer will send you a proffered permit for your reconsideration, as indicated in Section B below. B: PROFFERED PERMIT: You may accept or appeal the permit x ACCEPT: If you received a Standard Permit, you may sign the permit document and return it to the district engineer for final authorization. If you received a Letter of Permission (LOP), you may accept the LOP and your work is authorized. Your signature on the Standard Permit or acceptance of the LOP means that you accept the permit in its entirety, and waive all rights to appeal the permit, including its terms and conditions, and approved jurisdictional determinations associated with the permit. x APPEAL: If you choose to decline the proffered permit (Standard or LOP) because of certain terms and conditions therein, you may appeal the declined permit under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer. This form must be received by the division engineer within 60 days of the date of this notice. Planning Board - January 9, 2025 ITEM: 1 - 12 - 4 -2- C. PERMIT DENIAL WITHOUT PREJUDICE: Not appealable You received a permit denial without prejudice because a required Federal, state, and/or local authorization and/or certification has been denied for activities which also require a Department of the Army permit before final action has been taken on the Army permit application. The permit denial without prejudice is not appealable. There is no prejudice to the right of the applicant to reinstate processing of the Army permit application if subsequent approval is received from the appropriate Federal, state, and/or local agency on a previously denied authorization and/or certification. D: PERMIT DENIAL WITH PREJUDICE: You may appeal the permit denial You may appeal the denial of a permit under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer. This form must be received by the division engineer within 60 days of the date of this notice. E: APPROVED JURISDICTIONAL DETERMINATION: You may accept or appeal the approved JD or provide new information for reconsideration x ACCEPT: You do not need to notify the Corps to accept an approved JD. Failure to notify the Corps within 60 days of the date of this notice means that you accept the approved JD in its entirety and waive all rights to appeal the approved JD. x APPEAL: If you disagree with the approved JD, you may appeal the approved JD under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer. This form must be received by the division engineer within 60 days of the date of this notice. x RECONSIDERATION: You may request that the district engineer reconsider the approved JD by submitting new information or data to the district engineer within 60 days of the date of this notice. The district will determine whether the information submitted qualifies as new information or data that justifies reconsideration of the approved JD. A reconsideration request does not initiate the appeal process. You may submit a request for appeal to the division engineer to preserve your appeal rights while the district is determining whether the submitted information qualifies for a reconsideration. F: PRELIMINARY JURISDICTIONAL DETERMINATION: Not appealable You do not need to respond to the Corps regarding the preliminary JD. The Preliminary JD is not appealable. If you wish, you may request an approved JD (which may be appealed), by contacting the Corps district for further instruction. Also, you may provide new information for further consideration by the Corps to reevaluate the JD. POINT OF CONTACT FOR QUESTIONS OR INFORMATION: If you have questions regarding this decision you may contact: District Engineer, Wilmington Regulatory Division Attn: Brad Shaver Wilmington District U.S. Army Corps of Engineers 69 Darlington Ave Wilmington, NC 28403 If you have questions regarding the appeal process, or to submit your request for appeal, you may contact: Krista Sabin Regulatory Administrative Appeal Review Officer U.S. Army Corps of Engineers South Atlantic 60 Forsyth Street Room M9 Atlanta, Georgia 30303-8801 Phone: 904-314-9631 Email: Krista.D.Sabin@usace.army.mil SECTION II – REQUEST FOR APPEAL or OBJECTIONS TO AN INITIAL PROFFERED PERMIT Planning Board - January 9, 2025 ITEM: 1 - 12 - 5 -3- REASONS FOR APPEAL OR OBJECTIONS: (Describe your reasons for appealing the decision or your objections to an initial proffered permit in clear concise statements. Use additional pages as necessary. You may attach additional information to this form to clarify where your reasons or objections are addressed in the administrative record.) ADDITIONAL INFORMATION: The appeal is limited to a review of the administrative record, the Corps memorandum for the record of the appeal conference or meeting, and any supplemental information that the review officer has determined is needed to clarify the administrative record. Neither the appellant nor the Corps may add new information or analyses to the record. However, you may provide additional information to clarify the location of information that is already in the administrative record. RIGHT OF ENTRY: Your signature below grants the right of entry to Corps of Engineers personnel, and any government consultants, to conduct investigations of the project site during the course of the appeal process. You will be provided a 15-day notice of any site investigation and will have the opportunity to participate in all site investigations. _______________________________ Signature of appellant or agent. Date: Email address of appellant and/or agent: Telephone number: Planning Board - January 9, 2025 ITEM: 1 - 12 - 6 DEPARTMENT OF THE ARMY U.S. ARMY CORPS OF ENGINEERS, WILMINGTON DISTRICT 69 DARLING AVENUE WILMINGTON, NORTH CAROLINA 28403 [CESAW-RG-L] [21 August 2024] MEMORANDUM FOR RECORD SUBJECT: US Army Corps of Engineers (Corps) Approved Jurisdictional Determination in accordance with the “Revised Definition of ‘Waters of the United States’”; (88 FR 3004 (January 18, 2023) as amended by the “Revised Definition of ‘Waters of the United States’; Conforming” (8 September 2023) ,1 [SAW-2024-01415] [MFR 1 of 1]2 BACKGROUND. An Approved Jurisdictional Determination (AJD) is a Corps document stating the presence or absence of waters of the United States on a parcel or a written statement and map identifying the limits of waters of the United States on a parcel. AJDs are clearly designated appealable actions and will include a basis of JD with the document.3 AJDs are case-specific and are typically made in response to a request. AJDs are valid for a period of five years unless new information warrants revision of the determination before the expiration date or a District Engineer has identified, after public notice and comment, that specific geographic areas with rapidly changing environmental conditions merit re-verification on a more frequent basis.4 On January 18, 2023, the Environmental Protection Agency (EPA) and the Department of the Army (“the agencies”) published the “Revised Definition of ‘Waters of the United States,’” 88 FR 3004 (January 18, 2023) (“2023 Rule”). On September 8, 2023, the agencies published the “Revised Definition of ‘Waters of the United States’; Conforming”, which amended the 2023 Rule to conform to the 2023 Supreme Court decision in Sackett v. EPA, 598 U.S., 143 S. Ct. 1322 (2023) (“Sackett”). This Memorandum for Record (MFR) constitutes the basis of jurisdiction for a Corps AJD as defined in 33 CFR §331.2. For the purposes of this AJD, we have relied on Section 10 of the Rivers and Harbors Act of 1899 (RHA),5 the 2023 Rule as amended, 1 While the Revised Definition of “Waters of the United States”; Conforming had no effect on some categories of waters covered under the CWA, and no effect on any waters covered under RHA, all categories are included in this Memorandum for Record for efficiency. 2 When documenting aquatic resources within the review area that are jurisdictional under the Clean Water Act (CWA), use an additional MFR and group the aquatic resources on each MFR based on the TNW, the territorial seas, or interstate water that they are connected to. Be sure to provide an identifier to indicate when there are multiple MFRs associated with a single AJD request (i.e., number them 1, 2, 3, etc.). 3 33 CFR 331.2. 4 Regulatory Guidance Letter 05-02. 5 USACE has authority under both Section 9 and Section 10 of the Rivers and Harbors Act of 1899 but for convenience, in this MFR, jurisdiction under RHA will be referred to as Section 10. Planning Board - January 9, 2025 ITEM: 1 - 12 - 7 [CESAW-RG-L] SUBJECT: 2023 Rule, as amended, Approved Jurisdictional Determination in Light of Sackett v. EPA, 143 S. Ct. 1322 (2023), [SAW-2024-01415] 2 as well as other applicable guidance, relevant case law, and longstanding practice in evaluating jurisdiction. 1. SUMMARY OF CONCLUSIONS. a. Provide a list of each individual feature within the review area and the jurisdictional status of each one (i.e., identify whether each feature is/is not a water of the United States and/or a navigable water of the United States). i. Name of Aquatic Resource JD or Non-JD Section 404/Section 10 W1 JD Section 404 W2 JD Section 404 T1 JD Section 404 T2 JD Section 404 T3 JD Section 404 Excluded Pond Non-JD N/A 2. REFERENCES. a. “Revised Definition of ‘Waters of the United States,’” 88 FR 3004 (January 18, 2023) (“2023 Rule”) b. “Revised Definition of ‘Waters of the United States’; Conforming” 88 FR 61964 (September 8, 2023)) c. Sackett v. EPA, 598 U.S. _, 143 S. Ct. 1322 (2023) 3. REVIEW AREA. A. Project Are Size (in acres): 33.7 B. Center Coordinates of the Project Site (in decimal degrees) Latitude: 34.294687 Longitude: -77.78926 C. Nearest City or Town: Wilmington D. County: New Hanover E. State: North Carolina F. Other associated Jurisdictional Determinations (including outcomes): N/A G. Any additional, relevant site-specific information: The site was visited a few days after a major rain even that dropped almost 12” of rain. Planning Board - January 9, 2025 ITEM: 1 - 12 - 8 [CESAW-RG-L] SUBJECT: 2023 Rule, as amended, Approved Jurisdictional Determination in Light of Sackett v. EPA, 143 S. Ct. 1322 (2023), [SAW-2024-01415] 3 4. NEAREST TRADITIONAL NAVIGABLE WATER (TNW), THE TERRITORIAL SEAS, OR INTERSTATE WATER TO WHICH THE AQUATIC RESOURCE IS CONNECTED. A. Name of nearest downstream TNW, Territorial Sea or interstate water: The site drains toward Pages Creek which becomes tidal before it enters into the Intracoastal Waterway. B. Determination based on: This determination was made based on a review of desktop data resources listed in Section 9 of this memorandum and a field visit conducted on 8/15/2024, a review of the SAW Section 10 list, and documented (include in AR) occurrences of boating traffic on the identified water. 5. FLOWPATH FROM THE SUBJECT AQUATIC RESOURCES TO A TNW, THE TERRITORIAL SEAS, OR INTERSTATE WATER. The tributaries (T1, T2, and T3) are relatively permanent waters (RPWs) and are an unnamed tributaries to Pages Creek (located approximately 5,000 feet to the south where it becomes tidally influenced), a traditionally navigable water (TNW). The Ordinary High-Water Mark (OHWM) of the unnamed tributaries were indicated by the following physical characteristics: natural line impressed on the bank, shelving, absence of vegetation, scour, and bed and banks. The wetlands (W1 and W2) meet the hydrophytic vegetation, wetland hydrology, and hydric soil criteria of the 1987 Corps of Engineers Wetland Delineation Manual and the Atlantic and Gulf Coastal Plain Regional Supplement and are contiguous with the unnamed tributaries. 6. SECTION 10 JURISDICTIONAL WATERS6: Describe aquatic resources or other features within the review area determined to be jurisdictional in accordance with Section 10 of the Rivers and Harbors Act of 1899. Include the size of each aquatic resource or other feature within the review area and how it was determined to be jurisdictional in accordance with Section 10.7 [N/A] 6 33 CFR 329.9(a) A waterbody which was navigable in its natural or improved state, or which was susceptible of reasonable improvement (as discussed in § 329.8(b) of this part) retains its character as “navigable in law” even though it is not presently used for commerce, or is presently incapable of such use because of changed conditions or the presence of obstructions. 7 This MFR is not to be used to make a report of findings to support a determination that the water is a navigable water of the United States. The district must follow the procedures outlined in 33 CFR part 329.14 to make a determination that water is a navigable water of the United States subject to Section 10 of the RHA. Planning Board - January 9, 2025 ITEM: 1 - 12 - 9 [CESAW-RG-L] SUBJECT: 2023 Rule, as amended, Approved Jurisdictional Determination in Light of Sackett v. EPA, 143 S. Ct. 1322 (2023), [SAW-2024-01415] 4 7. SECTION 404 JURISDICTIONAL WATERS: Describe the aquatic resources within the review area that were found to meet the definition of waters of the United States in accordance with the 2023 Rule as amended, consistent with the Supreme Court’s decision in Sackett. List each aquatic resource separately, by name, consistent with the naming convention used in section 1, above. Include a rationale for each aquatic resource, supporting that the aquatic resource meets the relevant category of “waters of the United States” in the 2023 Rule as amended. The rationale should also include a written description of, or reference to a map in the administrative record that shows, the lateral limits of jurisdiction for each aquatic resource, including how that limit was determined, and incorporate relevant references used. Include the size of each aquatic resource in acres or linear feet and attach and reference related figures as needed. a. Traditional Navigable Waters (TNWs) (a)(1)(i): [N/A.] b. The Territorial Seas (a)(1)(ii): [N/A] c. Interstate Waters (a)(1)(iii): [N/A.] d. Impoundments (a)(2): [N/A.] e. Tributaries (a)(3): Name of Aquatic Resource Size (in linear feet) Flow Regime and additional description of the tributary Method for determining flow regime T1 675 See attached delineation map Observed flow during site visit during site visit. T2 1,620 See attached delineation map Observed flow during site visit during site visit. T3 110 See attached delineation map Observed flow during site visit during site visit. f. Adjacent Wetlands (a)(4): Name of Aquatic Resource Size (in acres) Contiguous with or abutting? If so, list water Describe continuous surface connection W1 0.1 Yes, T2 The wetland boundary is connecting and contiguous with stream T2, an RPW. W2 1.2 Yes, T2 The wetland boundary is connecting and contiguous with stream T2, an RPW. g. Additional Waters (a)(5): [N/A] Planning Board - January 9, 2025 ITEM: 1 - 12 - 10 [CESAW-RG-L] SUBJECT: 2023 Rule, as amended, Approved Jurisdictional Determination in Light of Sackett v. EPA, 143 S. Ct. 1322 (2023), [SAW-2024-01415] 5 8. NON-JURISDICTIONAL AQUATIC RESOURCES AND FEATURES a. Describe aquatic resources and other features within the review area identified in the 2023 Rule as amended as not “waters of the United States” even where they otherwise meet the terms of paragraphs (a)(2) through (5). Include the type of excluded aquatic resource or feature, the size of the aquatic resource or feature within the review area and describe how it was determined to meet one of the exclusions listed in 33 CFR 328.3(b).8 Name of excluded feature Size (in acres) Specific exclusion (b)(1) - (b)(8) ExP1 1.3 (b)(5) Artificial lakes or ponds created by excavating or diking dry land to collect and retain water and which are used exclusively for such purposes as stock watering, irrigation, settling basins, or rice growing. b. Describe aquatic resources and features within the review area that were determined to be non-jurisdictional because they do not meet one or more categories of waters of the United States under the 2023 Rule as amended (e.g., tributaries that are non-relatively permanent waters; non-tidal wetlands that do not have a continuous surface connection to a jurisdictional water). [N/A] 9. DATA SOURCES. List sources of data/information used in making determination. Include titles and dates of sources used and ensure that information referenced is available in the administrative record. a. 1. Date of Office (desktop review):8/21/2024 2. Date(s) of Field Review (if applicable):8/15/2024 b. Data sources used to support this determination (included in the administrative record). ☒ Aquatic Resources delineation submitted by, or on behalf of, the requestor: Title and Date AJD package from Davey Resource Group ☐ Aquatic Resources delineation prepared by the USACE: Title and Date ☐ Wetland field data sheets prepared by the Corps: Title and Date ☐ OHWM data sheets prepared by the USACE: Title and Date ☐ Previous JDs (AJD or PJD) addressing the same (or portions of the same) review area: ORM Numbers and Dates ☐ Photographs: Source, Title, and Dates ☒ Aerial Imagery: Sources, Title, and Dates 2020 NC One Map ☒ LIDAR: Sources, Title, and Dates 2014 QL2 Lidar 8 88 FR 3004 (January 18, 2023) Planning Board - January 9, 2025 ITEM: 1 - 12 - 11 [CESAW-RG-L] SUBJECT: 2023 Rule, as amended, Approved Jurisdictional Determination in Light of Sackett v. EPA, 143 S. Ct. 1322 (2023), [SAW-2024-01415] 6 ☒ USDA NRCS Soil Survey: Title and Dates GIS Data New Hanover County ☐ USFWS NWI maps: Title and Dates ☒ USGS topographic maps: Title and Dates 7.5 minute Topo Scotts Hill ☐ USGS NHD data/maps: Title and Dates ☐ Section 10 resources used: Title and Dates ☐ NCDWR stream identification forms ☐ North Carolina Stream Assessment Method (NCSAM) forms ☐ North Carolina Wetland Assessment Method (NCWAM) forms ☒ Antecedent Precipitation Tool Analysis: List Date(s) 4/12-5/12 2024 ☐ Other sources of Information: List 10. OTHER SUPPORTING INFORMATION. [N/A] 11. NOTE: The structure and format of this MFR were developed in coordination with the EPA and Department of the Army. The MFR’s structure and format may be subject to future modification or may be rescinded as needed to implement additional guidance from the agencies; however, the approved jurisdictional determination described herein is a final agency action. Planning Board - January 9, 2025 ITEM: 1 - 12 - 12 Concept Plan Planning Board - January 9, 2025 ITEM: 1 - 13 - 1 US 1 7 N O R T H - M A R K E T S T R E E T H A Y S L A N E P O R T E R S N E C K R O A D US 1 7 N O R T H - M A R K E T S T R E E T H A Y S L A N E P O R T E R S N E C K R O A D Le Wa Le Ly Ly St Kr Le Le Le Ly RmMu Kr Ly Mu Rm Mu Le Ly Kr St Kr LyLy Ke Rm JO BeDO LaKrLe DECEMBER 2024 FOR WILMINGTON, NORTH CAROLINA BAYSHORE TOWNHOMES, LLC 201 NORTH ELM STREET GREENSBORO, NC 27401 MIXED USE AND ADDITIONAL DWELLING ALLOWANCE SUP NOTICE REQUIRED ALL EXISTING UNDERGROUND UTILITIES SHALL BE PHYSICALLY LOCATED PRIOR TO THE BEGINNING OF ANY CONSTRUCTION IN THE VICINITY OF SAID UTILITIES. CONTRACTORS SHALL NOTIFY OPERATORS WHO MAINTAIN UNDERGROUND UTILITY LINES IN THE AREA OF PROPOSED EXCAVATION AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN TEN WORKING DAYS PRIOR TO COMMENCEMENT OF EXCAVATION OR DEMOLITION. CONTRACTORS SHALL CONTACT OVERHEAD ELECTRIC PROVIDER TO COMPLY WITH FEDERAL OSHA 1910.333 MINIMUM APPROACH DISTANCE TO ENERGIZED POWERLINES AND OSH 29 CFR 1926.1407-1411 MUST BE FOLLOWED. CONTACT THESE UTILITIES NEW HANOVER COUNTY PLANNING PH: 910-798-7165 ENGINEERING PH: 910-798-7139 PIEDMONT NATURAL GAS ATTN: PAUL GONKA PH: 910-251-2810 EMERGENCY DIAL 911 POLICE - FIRE - RESCUE CAPE FEAR PUBLIC UTILITY AUTHORITY (WATER & SEWER) ENGINEERING/INSPECTIONS PH: 910-332-6560 OPERATIONS/MAINTENANCE PH: 910-322-6550 DUKE ENERGY PROGRESS DISTRIBUTION CONSTRUCTION SERVICE PH: 910-256-7258 DEP CSC PH: 1-800-452-2777 AT&T/BELL SOUTH ATTN: CHRISSY COSTON PH: 910-341-7664 TIME WARNER CABLE PH: 910-763-4638 NEW HANOVER COUNTY DEC. 2, 2024 C-0.0 COVER SHEET APPROVALS: LANDSCAPE ARCHITECT: WILMINGTON, NORTH CAROLINA BAYSHORE TOWNHOMES, LLC 201 NORTH ELM STREET GREENSBORO, NC 27401 PARAMOUNTE ENGINEERING, INC. 122 CINEMA DRIVE WILMINGTON, NORTH CAROLINA 28403 P: (910) 791-6707 ATTN: ROB BALLAND, PE (CIVIL ENGINEERING) ATTN: ALLISON ENGEBRETSON (LANDSCAPE ARCHITECT/ LAND PLANNER) PARAMOUNTE ENGINEERING, INC. 122 CINEMA DRIVE WILMINGTON, NORTH CAROLINA 28403 P: (910) 791-6707 ATTN: JOSH TAYLOR, PLS PROJECT # 24237.PE APPLICANT: ENGINEER / LAND PLANNER/ SURVEYOR : PREPARED BY: PR E L I M I N A R Y D E I S G N ; N O T R E L E A S E D F O R C O N S T R U C T I O N 122 Cinema Drive Wilmington, North Carolina 28403 (910) 791-6707 (O) (910) 791-6760 (F) NC License #: C-2846 BAYSHORE TOWNHOMES SUPs SHEET NUMBER SHEET TITLE SUP- B-2 ZONING SITE PLANC-2.1 VICINITY MAP SCALE: 1" = 1,000' SITE BAYSHORE TOWNHOMES SUP-OVERALL MASTER PLANC-2.0 C-3.1 C-3.2 C-4.1 SOILS MAP SCALE: 1" = 1,000' SITE EXISTING CONDITIONS SURVEYEX-1 SUP- R-15 ZONING SITE PLANC-2.2 C-4.2 SUP- B-2 ZONING DRAINAGE PLAN SUP- R-15 ZONING DRAINAGE PLAN SUP- B-2 ZONING UTILITY PLAN SUP- R-15 ZONING UTILITY PLAN Planning Board - January 9, 2025 ITEM: 1 - 14 - 1 TR 19P N W E T W E T W E T W E T WETWETWET WETWET WE T W E T W E T WETWET W E T WET WET W E T WET WE T W E T WE T WE T IPF IPF IRF IPF PKF IPF IPF IPFIPF CMF IPF IRF IRF INV: 23.14 12" CPP INV: DAMAGED N 0 5 ° 1 2 ' 0 1 " E 5 3 8 . 0 4 ' S 36°02' 1 6 " E 116.92' N 3 9 ° 3 9 ' 4 1 " E 33 0 . 6 1 ' S 50°28'07" E 115.22' N 3 9 ° 3 9 ' 0 6 " E 16 0 . 3 1 ' S 50°19'17" E 150.03' L1 L2 S 48°16'45" E 506.30' L3 S 47°46'24" E 121.53' S 48°24'53" E 581.39' S 4 1 ° 2 5 ' 4 8 " W 31 0 . 4 8 ' N 48°34'06" W 121.43' S 4 2 ° 5 5 ' 4 8 " W 75 0 . 7 0 ' L4 L5L6 L7L8L9N 47°17'46" W 107.98' L10L11L12 L13 L1 4 L1 5 L1 6 L17 L 1 8 L 1 9 L20 L 2 1 L 2 2 L 2 3 N 64°11'4 9 " W 421.13' S 4 1 ° 3 4 ' 5 0 " W 21 0 . 0 0 ' LOT 142 R03600-006-012-000 RICHARD MOBURG ELIZABETH MOBURG D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 143 R03600-006-013-000 NORA E. BENEVENTI REVOCABLE TRUST D.B. 5020, PG. 2264 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 144 R03600-006-014-000 DAVID M. RENQUIST MARY E. RENQUIST D.B. 5020, PG. 2264 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 147 R03600-006-017-000 PRUDENTIAL RELOCATION INC. D.B. 5238, PG. 722 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 148 R03600-006-018-000 BRADLEY J. ERBES TAMI L. ERBES D.B. 5238, PG. 722 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 149 R03600-006-024-000 ERNEST W. OLDS DAWN M. OLDS D.B. 6056, PG. 182 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL LOT 150 R03600-006-025-000 RICHARD MIMMS SUPATRA MIMMS D.B. 6221, PG. 2760 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL LOT 151 R03600-006-026-000 MADISON M. NEWSOME BUNJONG P. NEWSOME D.B. 4655, PG. 304 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL R03600-006-082-000 ROBERT L. YUNASKA D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: I-1 LAND USE: VACANT INDUSTRIAL ICV 40' DRAINAGE AND PUBLIC UTILITY EASEMENT D.B. 5053, PG.1637 R0 3 7 0 0 - 0 0 4 - 2 9 3 - 0 0 0 PO R T E R ' S P O I N T E HO M E O W N E R S AS S O C I A T I O N , I N C D. B . 5 7 9 0 , P G . 3 5 M. B . 5 5 , P G . 3 4 0 18' PRIVATE ALLEY R03700-004-293-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL COMMUNITY OPEN SPACE R03700-004-294-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL AMENITY R03705-006-007-000 KATHRYN WOLFE & LARRY STEVEN MORGAN D.B. 6025, PG. 1493 M.B. 46, PG. 25 ZONING: R-15 LAND USE: RESIDENTIAL R03705-006-012-000 JOANN M. WAINIO D.B. 5694, PG. 1838 M.B. 46, PG. 25 ZONING: R-15 LAND USE: RESIDENTIAL 30' SANITARY SEWER EASEMENT M.B. 46, PG. 25 L O T 4 8 R 0 3 7 0 0 - 0 0 4 - 2 7 9 - 0 0 0 J O R Y A N D E R S O N & A B B Y R I C H O M N D D . B . 6 6 7 5 , P G . 1 3 2 7 M. B . 5 5 , P G . 3 4 0 Z O N I N G : R - 1 5 L A N D U S E : R E S I D E N T I A L 36 . 2 ' 24.2' WELL R0 3 7 0 0 - 0 0 4 - 1 9 1 - 0 0 0 PO R T E R S C R O S S I N G HO A I N C D.B . 5 1 9 0 , P G . 1 2 0 4 M. B . 5 1 , P G . 1 5 4 ZO N I N G : R - 1 5 LA N D U S E : RE S I D E N T I A L A M E N I T Y R03700-004-301-000 DEREK REEVES D.B. 5625, PG. 1573 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-300-000 STEVE LINDNER D.B. 6031, PG. 2140 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-299-000 EDWARD SOUTHERLAND D.B. 5571, PG. 1535 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-298-000 ANNA ROVETTO D.B. 6636, PG. 1714 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-297-000 ROCHELLE KREINER D.B. 6406, PG. 1314 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-296-000 CAMERON DANIEL D.B. 6290, PG. 242 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-295-000 RICHARD WILSON D.B. 5545, PG. 2050 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-011-000 PORTERS CROSSING HOA INC D.B. 6102, PG. 2894 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL AMENITY 15 ' D R A I N A G E A N D P U B L I C UT I L I T Y E A S E M E N T M. B . 5 1 , P G . 1 5 4 20' UTILITY EASEMENT M.B. 49, PG. 102 R03700-004-214-000 LARRY J. & ALICE W. MATTHEWS D.B. 6489, PG. 1689 M.B. 49, PG. 102 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-215-000 AVERY & JOLIN BEVIN CRAIG & NANCY GIBSON D.B. 6647, PG. 715 M.B. 49, PG. 102 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-216-000 JESUS G. & ROSELINE H. DIZA-QUIROZ D.B. 5440, PG. 2569 M.B. 49, PG. 102 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-217-000 XIAODAN DONG & QIYONG WENG D.B. 6221, PG. 569 M.B. 49, PG. 102 ZONING: R-15 LAND USE: RESIDENTIAL 30 ' D R A I N A G E & U T I L I T Y E A S E M E N T M. B . 4 9 , P G . 1 0 2 30' PUBLIC UTILITY E A S E M E N T M.B. 51, PG. 154 20' DRAINAGE AND PUBLIC UTILITY EASEMENT M.B. 51, PG. 154 8GM BR A Y S D R I V E MIDSTREAM DRIVE 50' PUBLIC R/W SS SS S S S S S S S S SS SS SS SS SS SS SS SS SS SS SS SS SS SS S S S S S S SS SS SS SS SS SS SS SS S S S S SS SS SS 8" PVC 8" PVC 8 " P V C 8" PVC 8 " P V C 8" PV C 8" PVC 8" P V C 8" PVC 8" PVC TV TRSS SMH RIM = 30.20 INV = 15.14 SMH RIM =29.38 INV = 14.71 SMH RIM =30.67 INV = 12.96 SMH RIM =17.54 INV =11.05 SMH RIM = 17.61 UNABLE TO OPEN SMH RIM =17.62 INV = 10.45 SMH RIM =16.43 INV = 10.02 SMH RIM =16.62 INV =9.21 SMH RIM =16.94 INV =8.46 SMH RIM =18.18 INV =8.12 SMH RIM =18.45 INV = 11.25 S W E E T W A T E R B R A N C H SHACKLE F O R D D R I V E 52' PUBL I C R / W PID: R03700-004-147-000 (20.31 AC. ±) PID: R03700-004-148-000 (2.12 AC. ±) D.B. 5007, PG. 2900 PID: R03700-004-189-000 (7.79 AC. ±) D.B. 5102, PG. 1227 1,316,276 SQ. FT. ± 30.22 AC. ± R03700-004-293-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL COMMUNITY OPEN SPACE EXISTING POND W E T W E T X X X X X X X X X X X X SIGN SS SS SS SS SS SS SS ASPHALT LOT RAMP US H W Y . 1 7 - M A R K E T S T R E E T 10 0 ' P U B L I C R / W RETAINING WALL CHAINLINK FENCE X CHAINLINK FENCE IRF IPF IPF IPF AXLEIPF IPF OH E OH E DU K E E N E R G Y P R O G R E S S , L L C EA S E M E N T DB 6 0 9 6 , P G 1 2 8 8 BLDG BLDG P O L E B A R N BLDG CON C . PAD B L D G BL D G OFFICE BUILDING ASPHALT LOT CONCRETE CONCRETE W W W W W W W FO FO FO FO FO FO 4 WA T E R & S E W E R E A S E M E N T DB 5 2 2 2 , P G 1 8 4 7 XX 8 11 CA R O L I N A P O W E R & L I G H T C O M P A N Y DB 6 7 2 P G 1 7 7 9 10 50 ' F R O N T S E T B A C K W W W W W W W W W 16 " C L 8" P V C 18 " D I P S 36°02' 1 6 " E 116.92' N 4 2 ° 2 4 ' 0 1 " E 21 0 . 1 4 ' S 50°36'43" E 665.40' S 4 1 ° 3 4 ' 5 0 " W 21 0 . 0 0 ' N 50°36'43" W 668.41' BO U N D A R Y L I N E A G R E E M E N T D. B . 9 7 1 , P G . 4 8 6 M.B . 1 4 , P G . 6 TR A C T 3 R03600-006-082-000 ROBERT L. YUNASKA D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: I-1 LAND USE: VACANT INDUSTRIAL BEE SAFE PORTERS NECK, LLC PID: R03600-005-007-000 D.B. 4967, PG. 1104 M.B. 21, PG. 49 122,819 SQ. FT. ± 2.82 AC. ± BEE SAFE PORTERS NECK, LLC PID: R03600-005-006-002 DB 4967 PG 1108 M.B. 21, PG. 49 17,129 SQ. FT. ± 0.39 AC. ± BFP R03600-005-008-000 ZONING: B-2 LAND USE: COMMERCIAL STORAGE 24P N 4SY 14P A 12PN 11O K 12P N 8GM 9OK PN 24 PN 24 MA 10 LO 21 MA 12 MA 16 MA 12MA 10 MA 17 PN 24 LO 10 MA 10 LO 14 LO 16LO 60 LO 26 LO 14 MA 8 SY 14 4SY 24P N GM 9 WO 10 MA 11 MA 13MA 12 MA 9 MA 13 GM 12 GM 14 PN 24 MA 48 PN 24 MG 8MA 12 MA 16 LO 16 PN 23 LO12 LO 24LO 21 PN 26 LO 17 LO 14SY 26 WO 17 WO 42 WIO 12 WO 8LO 24LO 8 WO 20WO 10 SY 17WO 14WO 9 WO 9 WO 27WO 14WO 20WO 20 WO 24 MA 24 MAR K E T S T R E E T - U S 1 7 P O R T E R S N E C K R D BRA Y S D R N A D 8 3 0 30 60 120 180 240 SCALE: 1"=60' NOTES 1.AREA CALCULATED BY COORDINATE METHOD. 2.HORIZONTAL (NAD 83-2011) AND VERTICAL (NAVD 88) DATA WERE ESTABLISHED UTILIZING A TOPCON HIPER-V GPS RECEIVER OPERATING IN VRS MODE WITH REPEAT OBSERVATIONS. 3.THIS PARCEL IS LOCATED IN ZONE X – NOT A SPECIAL FLOOD HAZARD AREA – AS SHOWN ON FEMA FLOOD MAP NO. 3720326000K AND 3720316900K BEARING AN EFFECTIVE DATE OF 08/28/2018. 4.UTILITIES AS SHOWN ARE PLOTTED FROM INFORMATION VISIBLE IN THE FIELD AND FROM INFORMATION PROVIDED BY UTILITY COMPANIES. ADDITIONAL UTILITIES NOT SHOWN MAY EXIST. THE APPROPRIATE UTILITY COMPANIES SHOULD BE CONTACTED PRIOR TO LAND DISTURBING ACTIVITIES. 5.THIS LOT IS SUBJECT TO ALL UTILITY EASEMENTS, RESTRICTIONS, OR COVENANTS OF RECORD. 6.CONTOUR INTERVAL =1'. VICINITY MAP (NOT TO SCALE) SITE DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL CL I E N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 JW T JA E 1" = 6 0 ' 08 / 0 2 / 2 0 2 4 NE W H A N O V E R C O U N T Y , N C HA R N E T T T O W N S H I P & L A N D S O F B E E S A F E S T O R A G E , L L C EX I S T I N G C O N D I T I O N S S U R V E Y EX-1 24237.PE B A Y S H O R E T O W N H O M E S , L L C 20 1 N . E L M S T R E E T , S U I T E 2 0 1 GR E E N S B O R O , N C 2 7 4 0 1 LA N D S O F H E R B E R T P A R H A M LEGEND: IPF IRF IRS PKF PKS CMF CP BOUNDARY LINE ADJOINING BOUNDARY LINE RIGHT OF WAY EASEMENT LINE SETBACK LINE 100-YR FLOOD LINE EXISTING CONTOUR WETLAND LINE WATER LINE - STREAM IRON PIPE FOUND IRON ROD FOUND IRON ROD SET PK NAIL FOUND PK NAIL SET CONCRETE MONUMENT FOUND BENCH MARK COMPUTED POINT BACK FLOW PREVENTER TRANSFORMER GUY ANCHOR IRRIGATION CONTROL VALVE TELECOMMUNICATION UTILITY WATER METER WATER VALVE FIRE HYDRANT CLEAN-OUT SANITARY SEWER MANHOLE STORM DRAINAGE MANHOLE STORM DROP INLET STORM CURB INLET TREE ELECTRIC METER TR 100-YR BM 15 WET MA T C H L I N E MA T C H L I N E BFP ICV AP P L I C A N T I N F O R M A T I O N : Planning Board - January 9, 2025 ITEM: 1 - 14 - 2 N 0 5 ° 1 2 ' 0 1 " E 5 3 8 . 0 4 ' S 36°02' 1 6 " E 116.92' N 3 9 ° 3 9 ' 4 1 " E 33 0 . 6 1 ' S 50°28'07" E 115.22' N 3 9 ° 3 9 ' 0 6 " E 16 0 . 3 1 ' S 50°19'17" E 150.03' L1 L2 S 48°16'45" E 506.30'L3 S 47°46'24" E 121.53'S 48°24'53" E 581.39' S 4 1 ° 2 5 ' 4 8 " W 31 0 . 4 8 ' N 48°34'06" W 121.43' S 4 2 ° 5 5 ' 4 8 " W 75 0 . 7 0 ' L4 L5L6 L7L8L9N 47°17'46" W 107.98' L10L11L12 L13 L14 L1 5 L1 6 L17 L 1 8 L1 9 L20 L2 1 L 2 2 L2 3 N 64°11'49" W 421.13' N 4 2 ° 2 4 ' 0 1 " E 21 0 . 1 4 ' S 50°36'43" E 665.40' S 4 1 ° 3 4 ' 5 0 " W 21 0 . 0 0 ' N 50°36'43" W 668.41' LOT 142R03600-006-012-000 RICHARD MOBURG ELIZABETH MOBURG D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 143 R03600-006-013-000 NORA E. BENEVENTI REVOCABLE TRUST D.B. 5020, PG. 2264 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 144 R03600-006-014-000 DAVID M. RENQUIST MARY E. RENQUIST D.B. 5020, PG. 2264 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 147 R03600-006-017-000 PRUDENTIAL RELOCATION INC. D.B. 5238, PG. 722 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 148R03600-006-018-000 BRADLEY J. ERBES TAMI L. ERBES D.B. 5238, PG. 722 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 149 R03600-006-024-000 ERNEST W. OLDS DAWN M. OLDS D.B. 6056, PG. 182 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL LOT 150R03600-006-025-000 RICHARD MIMMS SUPATRA MIMMS D.B. 6221, PG. 2760 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL LOT 151 R03600-006-026-000 MADISON M. NEWSOME BUNJONG P. NEWSOMED.B. 4655, PG. 304 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL LOT 152 R03600-006-027-000 DEWAIN H. RAHE JOYCE W. RAHE R03600-006-082-000 ROBERT L. YUNASKA D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: I-1 LAND USE: VACANT INDUSTRIAL R0 3 7 0 0 - 0 0 4 - 2 9 3 - 0 0 0 PO R T E R ' S P O I N T E HO M E O W N E R S AS S O C I A T I O N , I N C D.B . 5 7 9 0 , P G . 3 5 M.B . 5 5 , P G . 3 4 0 18' PRIVATE ALLEY R03700-004-293-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL COMMUNITY OPEN SPACE R03700-004-294-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL AMENITY R03600-005-008-000 GREGORY POOLE EQUIPMENT COMPANY D.B. 6645, PG. 1746 ZONING: B-2 LAND USE: COMMERCIAL R03600-005-005-000 SANDERS FAMILY STORAGE, LLC D.B. 6001, PG. 1677 ZONING: B-2LAND USE: COMMERCIAL STORAGE R03705-006-007-000 KATHRYN WOLFE & LARRY STEVEN MORGAN D.B. 6025, PG. 1493 M.B. 46, PG. 25 ZONING: R-15 LAND USE: RESIDENTIAL R03705-006-012-000 JOANN M. WAINIO D.B. 5694, PG. 1838 M.B. 46, PG. 25 ZONING: R-15 LAND USE: RESIDENTIALL O T 4 8 R 0 3 7 0 0 - 0 0 4 - 2 7 9 - 0 0 0 J O R Y A N D E R S O N & A B B Y R I C H O M N D D. B . 6 6 7 5 , P G . 1 3 2 7 M. B . 5 5 , P G . 3 4 0 Z O N I N G : R - 1 5 L A N D U S E : R E S I D E N T I A L 36 . 2 ' 24.2' R0 3 7 0 0 - 0 0 4 - 1 9 1 - 0 0 0 PO R T E R S C R O S S I N G HO A I N C D.B . 5 1 9 0 , P G . 1 2 0 4 M.B . 5 1 , P G . 1 5 4 ZO N I N G : R - 1 5 LA N D U S E : RE S I D E N T I A L A M E N I T Y R03700-004-301-000 DEREK REEVES D.B. 5625, PG. 1573 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-300-000 STEVE LINDNER D.B. 6031, PG. 2140 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-299-000 EDWARD SOUTHERLAND D.B. 5571, PG. 1535 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-298-000 ANNA ROVETTO D.B. 6636, PG. 1714 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-297-000 ROCHELLE KREINER D.B. 6406, PG. 1314 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-296-000 CAMERON DANIEL D.B. 6290, PG. 242 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-295-000 RICHARD WILSON D.B. 5545, PG. 2050 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-011-000 PORTERS CROSSING HOA INC D.B. 6102, PG. 2894 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL AMENITY R03700-004-214-000 LARRY J. & ALICE W. MATTHEWS D.B. 6489, PG. 1689 M.B. 49, PG. 102 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-215-000 AVERY & JOLIN BEVIN CRAIG & NANCY GIBSON D.B. 6647, PG. 715 M.B. 49, PG. 102 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-216-000 JESUS G. & ROSELINE H. DIZA-QUIROZ D.B. 5440, PG. 2569 M.B. 49, PG. 102 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-217-000 XIAODAN DONG & QIYONG WENG D.B. 6221, PG. 569 M.B. 49, PG. 102 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-293-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL COMMUNITY OPEN SPACE WETWETWET W E T W E T WET W E T W E T WE T W E T WE T 20 ' W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W SSSSSSSSSS WWWWWWW W W W W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSS SSSSSSSS W WWWWWWWWWWWWWWWW WW X SU P - O V E R A L L M A S T E R P L A N C-2.0 12 . 0 2 . 2 4 1" = 1 0 0 ' AH E AH E RP B VICINITY MAP NOT TO SCALE NORTH 140 SITE LEGEND SUBJECT PROPERTY LINE WETWETWET WET WET WET WETLANDS PROPOSED BUILDINGS MAR K E T S T MA R S H RE A C H D R F O L L Y I S L A N D C T OA K S POR T E R S C R O S S I N G W A Y M A R S H DR P O R T E R S N E C K R D F U T C H C R E E K R D B A Y F I E L D D R 0 50 100 200 400 SCALE: 1"=100' GRAPHIC SCALEGRAPHIC SCALE PROPOSED POND BA Y S H O R E T O W N H O M E S NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 24237.PE BA Y S H O R E T O W N H O M E S , L L C 20 1 N O R T H E L M S T R E E T , S U I T E 2 0 1 GR E E N S B O R O , N C 2 7 4 0 1 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL AP P L I C A N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 PR E L I M I N A R Y D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N SITE DEVELOPMENT NOTES: B-2 MIXED-USE APARTMENTS / RETAIL SUP DESIGN REQUIREMENTS OPEN SPACE REQUIRED:20% OPEN SPACE PROVIDED:MEET OR EXCEED 20% MINIMUM B-2 PARKING REQUIREMENTS 1.5 SPACES REQUIRED PER 1 BEDROOM UNIT, 2 SPACES PER 2+ BEDROOM UNIT PARKING REQUIRED:(52) 1BD X 1.5 = 78 APARTMENT SPACES (10) 2 OR 3 BD (MAX.) X 2 = 20 APARTMENT SPACES TOTAL APARTMENT SPACES: 98 SPACES 1,800 SF (2.5 / 1000 SF) = 5 COMMERCIAL SPACES 104 TOTAL SPACES REQUIRED PARKING PROVIDED:107 SPACES, MINIMUM, PROVIDED, PARKING WILL BE ADJUSTED PER UDO IF UNIT TYPE CHANGES BUILDING DIMENSIONAL REQUIREMENTS: BUILDING HEIGHT: 3 STORIES OR 50' MAX HT BUILDING SETBACK: EXCEEDS 100' SHOD SETBACK, 25' MINIMUM SIDE AND REAR SETBACKS PARKING SETBACK: MEETS SHOD 25' MINIMUM SETBACK SITE DATA PROJECT ADDRESSES: PROPERTY OWNERS:BEE SAFE PORTERS NECK, LLC, HERBERT E PARHAM, AND B-2 PARCEL PINS: R03600-005-007-000 (± 2.82 AC) R03600-005-006-002 (± 0.39 AC) R-15 PARCEL PINS: R03700-004-147-000 (± 20.41 AC) R03700-004-148-000 (± 2.12 AC) R03700-004-189-000 (± 7.79 AC) ROAD CONNECTION PARCEL (NOT INCLUDED IN SUP REQUESTS): PROPERTY OWNER: ROBERT L YUNASKA R03600-006-082-000 (I-1 ZONING, ±0.02 AC) PROPOSED USE:MIXED-USE COMMERCIAL/RETAIL & RESIDENTIAL MULTI-FAMILY, TOWNHOME (ROWHOUSE) RESIDENTIAL FUTURE LAND USE CLASSIFICATION:URBAN MIXED USE, GENERAL RESIDENTIAL, GROWTH NODE TOTAL PROJECT SITE AREA:± 33.43 AC CURRENT ZONING: B-2 (±3.21 AC) & R-15 (±30.22 AC INCLUDING ± 1.30 AC IN COD) PROPOSED ZONING: SUP - B-2 MIXED USE & SUP- R-15 ADDITIONAL DWELLING ALLOWANCE DENSITY:SUP - B-2 MIXED USE B-2 DENSITY DENSITY ALLOWED: NO MAX. OR MIN. IDENTIFIED IN UDO DENSITY PROPOSED:B-2 DENSITY: 19.31 DU/AC SUP- R-15 ADDITIONAL DWELLING ALLOWANCE HIGH DENSITY RESIDENTIAL DENSITY ALLOWED:10.2 DU/AC PROPOSED DENSITY: 8.37 DU/AC EXCLUDING COD AREA 8.0 DU/AC INCLUDING COD AREA MAXIMUM TOTAL PROPOSED UNITS:304 TOTAL UNITS + RETAIL SPACE 242 TOWNHOMES (R-15) 62 APARTMENT UNITS (B-2) 1,800 SF RETAIL MAX. (B-2) EXISTING CONDITIONS/ ENVIRONMENTAL NOTES: FLOOD INFORMATION:THE SUBJECT PARCELS ARE LOCATED IN ZONE X – MINIMAL FLOOD RISK – AS SHOWN BY FEMA MAP NUMBER 3720316900K & 3720326000K BEARING AN EFFECTIVE DATE OF AUGUST 28, 2018. WETLAND INFORMATION:A PRELIMINARY WETLAND DELINEATION WAS PREPARED BY DAVEY RESOURCE GROUP AND REVIEWED ON-SITE BY THE USACE 8/15/24. WETLAND IMPACT PERMITS WILL BE SUBMITTED AND APPROVED PRIOR TO CONSTRUCTION OF THE PROPOSED DEVELOPMENT. SPECIMEN TREES:SPECIMEN TREES HAVE BEEN FOUND ON SITE & ARE BEING PRESERVED. ALL TREE REMOVAL & MITIGATION PLANS AND PERMIT REQUESTS WILL BE SUBMITTED TO NHC FOR REVIEW AND APPROVAL PRIOR TO TREE REMOVAL ON-SITE. EXISTING VEGETATION:THE SITE IS COMPRISED OF A MIXTURE OF OPEN GRASSED AREAS & WOODED AREAS. WETLANDS ALONG EXISTING CREEK ARE VEGETATED AND WILL REMAIN UNDISTURBED OUTSIDE OF ANY WETLAND IMPACTS PERMITTED FOR CONSTRUCTION OF THE ESSENTIAL SITE IMPROVEMENTS FOR THE PROPOSED DEVELOPMENT. CONSERVATION OVERLAY DISTRICT (COD): THE EXISTING POND LOCATED IN THE NORTHEASTERN SIDE OF THE SITE IS IDENTIFIED BY NHC'S UDO & ONLINE GIS AS A "NATURAL POND" COD. THIS COD WILL BE PRESERVED AND THE REQUIRED 50' HAS A 50' BUFFER AROUND THE COD WILL BE SELECTIVELY REVEGETATED IN ACCORDANCE WITH THE UDO. GENERAL NOTES: 1.THE PROPOSED DEVELOPMENT SHALL MEET OR EXCEED ALL NEW HANOVER COUNTY (NHC) ORDINANCE AND PERMIT REQUIREMENTS. 2.IF THE SUP IS GRANTED, THE B-2 AND R-15 PORTIONS OF THE SITE WILL BE CONSTRUCTED AS A COHESIVELY DESIGNED. PERMITTED, CONSTRUCTED, AND MAINTAINED. 3.THE HATCHED I-1 ZONED PROPERTY LOCATED BETWEEN THE B-2 AND R-15 SITE SHALL PROVIDE VEHICULAR, PEDESTRIAN, AND UTILITY ACCESS FOR ALL PARCELS WITHIN THE DEVELOPMENT BOUNDARY. 4.THE DEVELOPMENT SHALL HAVE A HOA / POA IF / AS APPLICABLE. 5.STORM WATER SHALL BE DESIGNED AND PERMITTED IN ACCORDANCE WITH ALL NEW HANOVER COUNTY AND STATE REQUIREMENTS. 6.PUBLIC WATER AND SEWER WILL BE EXTENDED BY THE DEVELOPER TO THE SITE. ALL DESIGN AND PERMITTING SHALL BE COORDINATED WITH CFPUA, NEW HANOVER COUNTY, AND STATE REGULATORS AS REQUIRED. 7.ALL LANDSCAPE & BUFFER MATERIALS AND INSTALLATION SHALL MEET OR EXCEED NHC UDO REQUIREMENTS. 8.LOCATIONS OF ALL AMENITY AND RECREATION AREAS MAY CHANGE PENDING FINAL DESIGN 9.EXISTING TREES PROPOSED FOR PRESERVATION, BUT WILL BE FURTHER EVALUATED WITH FINAL DESIGN; TREE MITIGATION WILL BE REVIEWED WITH PART OF TREE REMOVAL PERMIT. 3 4 7 21 21 25 27 28 32 31 54 36 37 42 44 45 46 47 US H W Y . 1 7 - M A R K E T S T R E E T 10 0 ' P U B L I C R / W R-15 SUP DESIGN REQUIREMENTS: IMPERVIOUS SURFACE ALLOWED: 40% MAX. IMPERVIOUS SURFACE PROVIDED:40% MAX. OPEN SPACE REQUIRED:35% OPEN SPACE PROVIDED:MEET OR EXCEED 35% MINIMUM PARKING REQUIREMENTS - R-15 DWELLING, ROW-STYLE (TOWNHOMES) 2 SPACES REQUIRED PER DWELLING UNIT TOWNHOME PARKING REQUIRED:484 SPACES TOWNHOME PARKING PROVIDED:484 SPACES MINIMUM; VISITOR SPACES PROVIDED IN PARALLEL PARKING SPACES BUILDING DIMENSIONAL REQUIREMENTS: BUILDING HEIGHT: 40' MAX HT BUILDING SETBACK: EXCEEDS 20' SINGLE FAMILY AND 30' MULTI-FAMILY SETBACKS BR A Y S D R I V E 52 ' P U B L I C R / W SH A C K L E F O R D D R I V E 52' P U B L I C R / W 8 5 9 26 51 34 34 34 35 35 55 53 34 43 43 49 50 48 2 57 30 61 1B 1A 2 43A 38 65 64 38 66 7 9 8 23 24 22 11 48 15 16 17 19 52 44 38 33 23 22 24 58 67 6820 57 60 63 62 56 59 30 EXISTING TREE PROPOSED TREE KEY LEGEND: STORM PIPE (SEE GRADING & DRAINAGE PLAN) STORM STRUCTURE (SEE GRADING & DRAINAGE PLAN) STORMWATER POND STORMWATER OUTFALL LEVEL SPREADER EMERGENCY STORMWATER OUTFALL EXISTING NON-WETLAND WATERS OF THE US WETLAND IMPACTED FOR ROAD CROSSING WETLANDS PER APPROVED USACE AJD WETLAND DELINEATION DATED 08/26/2024 EXISTING POND IDENTIFIED AS "NATURAL POND" CONSERVATION AREA IN NHC UDO. POND TO REMAIN AND HAVE COD BUFFER SWALE PROVIDING OUTFALL DRAINAGE FOR EXISTING POND ADA LOADING SPACE (TYP) ADA PARKING SPACE SIGNAGE (TYP) WATER MAIN (SEE UTILITY PLAN) WATER SERVICE (DOMESTIC) (SEE UTILITY PLAN) WATER SERVICE (FIRE) (SEE UTILITY PLAN) WATER METER (SEE UTILITY PLAN) FIRE HYDRANT (SEE UTILITY PLAN) SANITARY SEWER MAIN (SEE UTILITY PLAN) SANITARY SEWER SERVICE (SEE UTILITY PLAN) SEWER CLEANOUT (SEE UTILITY PLAN) 1A HEAVY DUTY ASPHALT PAVING, TYP. (SEE DETAILS) LIGHT DUTY ASPHALT PAVING, TYP. (SEE DETAILS) CURB AND GUTTER VERTICAL CURB CONCRETE SIDEWALK INTERCONNECTED SIDEWALK,TRAIL SYSTEM THROUGHOUT PROJECT ADA CURB RAMP WITH TRUNCATED DOMES WARNING MAT SPECIMEN LIVE OAK CLUSTER PRESERVED PEDESTRIAN CROSSING LOCATION PARKING LOT STRIPING ADA PARKING SPACE (TYP) 2 4 5 6 7 8 10 11 12 13 14 15 16 17 18 20 21 22 23 24 25 26 27 28 29 1B 9 3019 20' WIDE DRAINAGE EASEMENT IN I-1 PARCEL ROAD CONNECTION BETWEEN B-2 AND R-15 PARCELS ALL NECESSARY UTILITY AND STORMWATER EASEMENTS CONVEYED BETWEEN B-2 AND R-15 PARCELS LOCATED ALONG ROAD I-1 PARCEL ROAD CONNECTION BETWEEN B-2 AND R-15 PARCELS MAINTENANCE BUILDING MINIMUM R-15 REQUIRED BUILDING SETBACK TO ADJACENT RESIDENTIAL 25' MINIMUM REQUIRED BUILDING SETBACK IN B-2 DISTRICT BUILDING SETBACKS EXCEED MINIMUM REQUIREMENT IN ALL LOCATIONS CLUBHOUSE / PROPERTY MANAGEMENT OFFICE / FITNESS / RECREATION CENTER FENCED POOL W/ SUMMER KITCHEN AND CABANA(S) BUILDING LANDSCAPE AREA FOUNDATION PLANTINGS AROUND ALL BUILDINGS, TYP. SEGMENTAL RETAINING WALL 32 33 34 36 38 31 3 4" HIGH CONCRETE WHEELSTOP STREET LIGHT, TYP. NATURE TRAIL EXISTING VEGETATION / LANDSCAPE BUFFER COMBINATION OF EXISTING & PLANTED VEGETATION CREATING BUFFER TO ADJACENT PROPERTIES; BUFFERS EXCEED MINIMUM BUFFER REQUIRED MINIMUM BUFFER LINE PROPOSED LANDSCAPE STREET TREES ALONG ALL PROJECT ROADS AND IN LANDSCAPE ISLANDS TRASH & RECYCLING COMPACTOR W/ SCREEN MONUMENT SIGN EMERGENCY-ONLY GATED ACCESS GATED ACCESS FOR EMERGENCY VEHICLES EQUIPPED WITH KNOX BOX/LOCK. ALIGN PAVING WITH BRAYS DRIVE 40 41 42 43 44 45 46 50 51 EXISTING TREE, TYP. PICKLEBALL COURTS SEE GENERAL NOTES OPEN SPACE, TYP. DOG PARK SEE GENERAL NOTES MOTOR COURT, TYP. RESIDENTS' PARKING AT CORE OF EACH BLOCK BEHIND UNITS. GARAGE ACCESS PROVIDED IN MOTOR COURT STREETYARD 25' MINIMUM REQUIRED 50' MAXIMUM SHOD PARKING SETBACK 100' MAXIMUM SHOD BUILDING SETBACK EXISTING 40' DRAINAGE & PUBLIC UTILITY EASEMENT EXISTING 30' DUKE ENERGY PROGRESS, LLC EASEMENT TO BE RELOCATED, PENDING DUKE APPROVAL 37 39 47 35 48 49 52 53 54 55 57 58 56 60 61 59 EXISTING 30' PUBLIC UTILITY EASEMENT EXISTING 15' DRAINAGE & PUBLIC UTILITY EASEMENT EXISTING 30' SANITARY SEWER EASEMENT EXISTING 30' DRAINAGE & PUBLIC UTILITY EASEMENT EXISTING 20' UTILITY EASEMENT EXISTING 20' DRAINAGE & UTILITY EASEMENT COMMERCIAL SPACE BETWEEN 1700 SF AND 1800 SF MIXED USE BUILDING MULTI-FAMILY BUILDING ALL RESIDENTIAL APARTMENTS 3-STORY ROW STYLE TOWNHOME WITH IN-UNIT GARAGE, TYP. 2-STORY END-UNIT ROW STYLE TOWNHOME, NO GARAGE, TYP. 63 62 43A 64 65 66 67 68 MIDSTREAM DRIVE 50' PUBLIC R/W Planning Board - January 9, 2025 ITEM: 1 - 14 - 3 S 36°02' 1 6 " E 116.92' N 4 2 ° 2 4 ' 0 1 " E 21 0 . 1 4 ' S 50°36'43" E 665.40' S 4 1 ° 3 4 ' 5 0 " W 21 0 . 0 0 ' N 50°36'43" W 668.41' R03600-006-082-000 ROBERT L. YUNASKA D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: I-1 LAND USE: VACANT INDUSTRIAL R03600-005-008-000 GREGORY POOLE EQUIPMENT COMPANY D.B. 6645, PG. 1746 ZONING: B-2 LAND USE: COMMERCIAL R03600-005-005-000 SANDERS FAMILY STORAGE, LLC D.B. 6001, PG. 1677 ZONING: B-2 LAND USE: COMMERCIAL STORAGE 20 ' SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W SU P - B - 2 Z O N I N G S I T E P L A N C-2.1 12 . 0 2 . 2 4 1" = 5 0 ' AH E AH E RP B VICINITY MAP NOT TO SCALE NORTH 140 SITE MAR K E T S T MA R S H RE A C H D R F O L L Y I S L A N D C T OA K S POR T E R S C R O S S I N G W A Y M A R S H DR P O R T E R S N E C K R D F U T C H C R E E K R D B A Y F I E L D D R 0 25 50 100 200 SCALE: 1"=50' GRAPHIC SCALEGRAPHIC SCALE BA Y S H O R E T O W N H O M E S NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 24237.PE BA Y S H O R E T O W N H O M E S , L L C 20 1 N O R T H E L M S T R E E T , S U I T E 2 0 1 GR E E N S B O R O , N C 2 7 4 0 1 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL AP P L I C A N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 PR E L I M I N A R Y D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N 2 3 4 6 7 8 9 31 32 54 38 41 44 46 5 10 53 55 US H W Y . 1 7 - M A R K E T S T R E E T 10 0 ' P U B L I C R / W SITE DATA PROJECT ADDRESSES: PROPERTY OWNERS:BEE SAFE PORTERS NECK, LLC, HERBERT E PARHAM, AND B-2 PARCEL PINS: R03600-005-007-000 (± 2.82 AC) R03600-005-006-002 (± 0.39 AC) R-15 PARCEL PINS: R03700-004-147-000 (± 20.41 AC) R03700-004-148-000 (± 2.12 AC) R03700-004-189-000 (± 7.79 AC) ROAD CONNECTION PARCEL (NOT INCLUDED IN SUP REQUESTS): PROPERTY OWNER: ROBERT L YUNASKA R03600-006-082-000 (I-1 ZONING, ±0.02 AC) PROPOSED USE:MIXED-USE COMMERCIAL/RETAIL & RESIDENTIAL MULTI-FAMILY, TOWNHOME (ROWHOUSE) RESIDENTIAL FUTURE LAND USE CLASSIFICATION:URBAN MIXED USE, GENERAL RESIDENTIAL, GROWTH NODE TOTAL PROJECT SITE AREA:± 33.43 AC CURRENT ZONING: B-2 (±3.21 AC) & R-15 (±30.22 AC INCLUDING ± 1.30 AC IN COD) PROPOSED ZONING: SUP - B-2 MIXED USE & SUP- R-15 ADDITIONAL DWELLING ALLOWANCE DENSITY:SUP - B-2 MIXED USE B-2 DENSITY DENSITY ALLOWED: NO MAX. OR MIN. IDENTIFIED IN UDO DENSITY PROPOSED:B-2 DENSITY: 19.31 DU/AC SUP- R-15 ADDITIONAL DWELLING ALLOWANCE HIGH DENSITY RESIDENTIAL DENSITY ALLOWED:10.2 DU/AC PROPOSED DENSITY: 8.37 DU/AC EXCLUDING COD AREA 8.0 DU/AC INCLUDING COD AREA MAXIMUM TOTAL PROPOSED UNITS:304 TOTAL UNITS + RETAIL SPACE 242 TOWNHOMES (R-15) 62 APARTMENT UNITS (B-2) 1,800 SF RETAIL MAX. (B-2) SITE DEVELOPMENT NOTES: B-2 MIXED-USE APARTMENTS / RETAIL SUP DESIGN REQUIREMENTS OPEN SPACE REQUIRED:20% OPEN SPACE PROVIDED:MEET OR EXCEED 20% MINIMUM B-2 PARKING REQUIREMENTS 1.5 SPACES REQUIRED PER 1 BEDROOM UNIT, 2 SPACES PER 2+ BEDROOM UNIT PARKING REQUIRED:(52) 1BD X 1.5 = 78 APARTMENT SPACES (10)2 OR 3 BD (MAX.) X 2 = 20 APARTMENT SPACES TOTAL APARTMENT SPACES: 98 SPACES 1,800 SF (2.5 / 1000 SF) = 5 COMMERCIAL SPACES 103 TOTAL SPACES REQUIRED PARKING PROVIDED:107 SPACES, MINIMUM, PROVIDED, PARKING WILL BE ADJUSTED PER UDO IF UNIT TYPE CHANGES BUILDING DIMENSIONAL REQUIREMENTS: BUILDING HEIGHT: 3 STORIES OR 50' MAX HT BUILDING SETBACK: EXCEEDS 100' SHOD SETBACK, 25' MINIMUM SIDE AND REAR SETBACKS PARKING SETBACK: MEETS SHOD 25' MINIMUM SETBACK GENERAL NOTES: 1.THE PROPOSED DEVELOPMENT SHALL MEET OR EXCEED ALL NEW HANOVER COUNTY (NHC) ORDINANCE AND PERMIT REQUIREMENTS. 2.IF THE SUP IS GRANTED, THE B-2 AND R-15 PORTIONS OF THE SITE WILL BE CONSTRUCTED AS A COHESIVELY DESIGNED. PERMITTED, CONSTRUCTED, AND MAINTAINED. 3.THE HATCHED I-1 ZONED PROPERTY LOCATED BETWEEN THE B-2 AND R-15 SITE SHALL PROVIDE VEHICULAR, PEDESTRIAN, AND UTILITY ACCESS FOR ALL PARCELS WITHIN THE DEVELOPMENT BOUNDARY. 4.THE DEVELOPMENT SHALL HAVE A HOA / POA IF / AS APPLICABLE. 5.STORM WATER SHALL BE DESIGNED AND PERMITTED IN ACCORDANCE WITH ALL NEW HANOVER COUNTY AND STATE REQUIREMENTS. 6.PUBLIC WATER AND SEWER WILL BE EXTENDED BY THE DEVELOPER TO THE SITE. ALL DESIGN AND PERMITTING SHALL BE COORDINATED WITH CFPUA, NEW HANOVER COUNTY, AND STATE REGULATORS AS REQUIRED. 7.ALL LANDSCAPE & BUFFER MATERIALS AND INSTALLATION SHALL MEET OR EXCEED NHC UDO REQUIREMENTS. 8.LOCATIONS OF ALL AMENITY AND RECREATION AREAS MAY CHANGE PENDING FINAL DESIGN 9.EXISTING TREES PROPOSED FOR PRESERVATION, BUT WILL BE FURTHER EVALUATED WITH FINAL DESIGN; TREE MITIGATION WILL BE REVIEWED WITH PART OF TREE REMOVAL PERMIT. EXISTING CONDITIONS/ ENVIRONMENTAL NOTES: FLOOD INFORMATION:THE SUBJECT PARCELS ARE LOCATED IN ZONE X – MINIMAL FLOOD RISK – AS SHOWN BY FEMA MAP NUMBER 3720316900K & 3720326000K BEARING AN EFFECTIVE DATE OF AUGUST 28, 2018. WETLAND INFORMATION:A PRELIMINARY WETLAND DELINEATION WAS PREPARED BY DAVEY RESOURCE GROUP AND REVIEWED ON-SITE BY THE USACE 8/15/24. WETLAND IMPACT PERMITS WILL BE SUBMITTED AND APPROVED PRIOR TO CONSTRUCTION OF THE PROPOSED DEVELOPMENT. SPECIMEN TREES:SPECIMEN TREES HAVE BEEN FOUND ON SITE & ARE BEING PRESERVED. ALL TREE REMOVAL & MITIGATION PLANS AND PERMIT REQUESTS WILL BE SUBMITTED TO NHC FOR REVIEW AND APPROVAL PRIOR TO TREE REMOVAL ON-SITE. EXISTING VEGETATION:THE SITE IS COMPRISED OF A MIXTURE OF OPEN GRASSED AREAS & WOODED AREAS. WETLANDS ALONG EXISTING CREEK ARE VEGETATED AND WILL REMAIN UNDISTURBED OUTSIDE OF ANY WETLAND IMPACTS PERMITTED FOR CONSTRUCTION OF THE ESSENTIAL SITE IMPROVEMENTS FOR THE PROPOSED DEVELOPMENT. CONSERVATION OVERLAY DISTRICT (COD): THE EXISTING POND LOCATED IN THE NORTHEASTERN SIDE OF THE SITE IS IDENTIFIED BY NHC'S UDO & ONLINE GIS AS A "NATURAL POND" COD. THIS COD WILL BE PRESERVED AND THE REQUIRED 50' HAS A 50' BUFFER AROUND THE COD WILL BE SELECTIVELY REVEGETATED IN ACCORDANCE WITH THE UDO. 35 35 1B 40 57 64 65 66 35 KEY LEGEND: STORM PIPE (SEE GRADING & DRAINAGE PLAN) STORM STRUCTURE (SEE GRADING & DRAINAGE PLAN) STORMWATER POND STORMWATER OUTFALL LEVEL SPREADER EMERGENCY STORMWATER OUTFALL EXISTING NON-WETLAND WATERS OF THE US WETLAND IMPACTED FOR ROAD CROSSING WETLANDS PER APPROVED USACE AJD WETLAND DELINEATION DATED 08/26/2024 EXISTING POND IDENTIFIED AS "NATURAL POND" CONSERVATION AREA IN NHC UDO. POND TO REMAIN AND HAVE COD BUFFER SWALE PROVIDING OUTFALL DRAINAGE FOR EXISTING POND ADA LOADING SPACE (TYP) ADA PARKING SPACE SIGNAGE (TYP) WATER MAIN (SEE UTILITY PLAN) WATER SERVICE (DOMESTIC) (SEE UTILITY PLAN) WATER SERVICE (FIRE) (SEE UTILITY PLAN) WATER METER (SEE UTILITY PLAN) FIRE HYDRANT (SEE UTILITY PLAN) SANITARY SEWER MAIN (SEE UTILITY PLAN) SANITARY SEWER SERVICE (SEE UTILITY PLAN) SEWER CLEANOUT (SEE UTILITY PLAN) 1A HEAVY DUTY ASPHALT PAVING, TYP. (SEE DETAILS) LIGHT DUTY ASPHALT PAVING, TYP. (SEE DETAILS) CURB AND GUTTER VERTICAL CURB CONCRETE SIDEWALK INTERCONNECTED SIDEWALK,TRAIL SYSTEM THROUGHOUT PROJECT ADA CURB RAMP WITH TRUNCATED DOMES WARNING MAT SPECIMEN LIVE OAK CLUSTER PRESERVED PEDESTRIAN CROSSING LOCATION PARKING LOT STRIPING ADA PARKING SPACE (TYP) 2 4 5 6 7 8 10 11 12 13 14 15 16 17 18 20 21 22 23 24 25 26 27 28 29 1B 9 3019 20' WIDE DRAINAGE EASEMENT IN I-1 PARCEL ROAD CONNECTION BETWEEN B-2 AND R-15 PARCELS ALL NECESSARY UTILITY AND STORMWATER EASEMENTS CONVEYED BETWEEN B-2 AND R-15 PARCELS LOCATED ALONG ROAD I-1 PARCEL ROAD CONNECTION BETWEEN B-2 AND R-15 PARCELS MAINTENANCE BUILDING MINIMUM R-15 REQUIRED BUILDING SETBACK TO ADJACENT RESIDENTIAL 25' MINIMUM REQUIRED BUILDING SETBACK IN B-2 DISTRICT BUILDING SETBACKS EXCEED MINIMUM REQUIREMENT IN ALL LOCATIONS CLUBHOUSE / PROPERTY MANAGEMENT OFFICE / FITNESS / RECREATION CENTER FENCED POOL W/ SUMMER KITCHEN AND CABANA(S) BUILDING LANDSCAPE AREA FOUNDATION PLANTINGS AROUND ALL BUILDINGS, TYP. SEGMENTAL RETAINING WALL 32 33 34 36 38 31 3 4" HIGH CONCRETE WHEELSTOP STREET LIGHT, TYP. NATURE TRAIL EXISTING VEGETATION / LANDSCAPE BUFFER COMBINATION OF EXISTING & PLANTED VEGETATION CREATING BUFFER TO ADJACENT PROPERTIES; BUFFERS EXCEED MINIMUM BUFFER REQUIRED MINIMUM BUFFER LINE PROPOSED LANDSCAPE STREET TREES ALONG ALL PROJECT ROADS AND IN LANDSCAPE ISLANDS TRASH & RECYCLING COMPACTOR W/ SCREEN MONUMENT SIGN EMERGENCY-ONLY GATED ACCESS GATED ACCESS FOR EMERGENCY VEHICLES EQUIPPED WITH KNOX BOX/LOCK. ALIGN PAVING WITH BRAYS DRIVE 40 41 42 43 44 45 46 50 51 EXISTING TREE, TYP. PICKLEBALL COURTS SEE GENERAL NOTES OPEN SPACE, TYP. DOG PARK SEE GENERAL NOTES MOTOR COURT, TYP. RESIDENTS' PARKING AT CORE OF EACH BLOCK BEHIND UNITS. GARAGE ACCESS PROVIDED IN MOTOR COURT STREETYARD 25' MINIMUM REQUIRED 50' MAXIMUM SHOD PARKING SETBACK 100' MAXIMUM SHOD BUILDING SETBACK EXISTING 40' DRAINAGE & PUBLIC UTILITY EASEMENT EXISTING 30' DUKE ENERGY PROGRESS, LLC EASEMENT TO BE RELOCATED, PENDING DUKE APPROVAL 37 39 47 35 48 49 52 53 54 55 57 58 56 60 61 59 EXISTING 30' PUBLIC UTILITY EASEMENT EXISTING 15' DRAINAGE & PUBLIC UTILITY EASEMENT EXISTING 30' SANITARY SEWER EASEMENT EXISTING 30' DRAINAGE & PUBLIC UTILITY EASEMENT EXISTING 20' UTILITY EASEMENT EXISTING 20' DRAINAGE & UTILITY EASEMENT COMMERCIAL SPACE BETWEEN 1700 SF AND 1800 SF MIXED USE BUILDING MULTI-FAMILY BUILDING ALL RESIDENTIAL APARTMENTS 3-STORY ROW STYLE TOWNHOME WITH IN-UNIT GARAGE, TYP. 2-STORY END-UNIT ROW STYLE TOWNHOME, NO GARAGE, TYP. 63 62 43A 64 65 66 67 68 20 16 19 17 1115 30 35 35 Planning Board - January 9, 2025 ITEM: 1 - 14 - 4 N 0 5 ° 1 2 ' 0 1 " E 5 3 8 . 0 4 ' S 36°02' 1 6 " E 116.92' N 3 9 ° 3 9 ' 4 1 " E 33 0 . 6 1 ' S 50°28'07" E 115.22' N 3 9 ° 3 9 ' 0 6 " E 16 0 . 3 1 ' S 50°19'17" E 150.03' L1 L2 S 48°16'45" E 506.30'L3 S 47°46'24" E 121.53'S 48°24'53" E 581.39' S 4 1 ° 2 5 ' 4 8 " W 31 0 . 4 8 ' N 48°34'06" W 121.43' S 4 2 ° 5 5 ' 4 8 " W 75 0 . 7 0 ' L4 L5L6 L7L8L9N 47°17'46" W 107.98' L10L11L12 L13 L1 4 L1 5 L1 6 L17 L 1 8 L 1 9 L20 L 2 1 L 2 2 L 2 3 N 64°11'49 " W 421.13' S 4 1 ° 3 4 ' 5 0 " W 21 0 . 0 0 ' LOT 142 R03600-006-012-000 RICHARD MOBURG ELIZABETH MOBURG D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 143 R03600-006-013-000 NORA E. BENEVENTI REVOCABLE TRUST D.B. 5020, PG. 2264 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 144 R03600-006-014-000 DAVID M. RENQUIST MARY E. RENQUIST D.B. 5020, PG. 2264 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 147 R03600-006-017-000 PRUDENTIAL RELOCATION INC. D.B. 5238, PG. 722 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 148 R03600-006-018-000 BRADLEY J. ERBES TAMI L. ERBES D.B. 5238, PG. 722 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 149 R03600-006-024-000 ERNEST W. OLDS DAWN M. OLDS D.B. 6056, PG. 182 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL LOT 150 R03600-006-025-000 RICHARD MIMMS SUPATRA MIMMS D.B. 6221, PG. 2760 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL LOT 151 R03600-006-026-000 MADISON M. NEWSOME BUNJONG P. NEWSOME D.B. 4655, PG. 304 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL R03600-006-082-000 ROBERT L. YUNASKA D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: I-1 LAND USE: VACANT INDUSTRIAL R0 3 7 0 0 - 0 0 4 - 2 9 3 - 0 0 0 PO R T E R ' S P O I N T E HO M E O W N E R S AS S O C I A T I O N , I N C D. B . 5 7 9 0 , P G . 3 5 M. B . 5 5 , P G . 3 4 0 18' PRIVATE ALLEY R03700-004-293-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL COMMUNITY OPEN SPACE R03700-004-294-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL AMENITY R03705-006-007-000 KATHRYN WOLFE & LARRY STEVEN MORGAN D.B. 6025, PG. 1493 M.B. 46, PG. 25 ZONING: R-15 LAND USE: RESIDENTIAL R03705-006-012-000 JOANN M. WAINIO D.B. 5694, PG. 1838 M.B. 46, PG. 25 ZONING: R-15 LAND USE: RESIDENTIAL L O T 4 8 R 0 3 7 0 0 - 0 0 4 - 2 7 9 - 0 0 0 J O R Y A N D E R S O N & A B B Y R I C H O M N D D . B . 6 6 7 5 , P G . 1 3 2 7 M . B . 5 5 , P G . 3 4 0 Z O N I N G : R - 1 5 L A N D U S E : R E S I D E N T I A L 36 . 2 ' 24.2' R0 3 7 0 0 - 0 0 4 - 1 9 1 - 0 0 0 PO R T E R S C R O S S I N G HO A I N C D.B . 5 1 9 0 , P G . 1 2 0 4 M. B . 5 1 , P G . 1 5 4 ZO N I N G : R - 1 5 LA N D U S E : RE S I D E N T I A L A M E N I T Y R03700-004-301-000 DEREK REEVES D.B. 5625, PG. 1573 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-300-000 STEVE LINDNER D.B. 6031, PG. 2140 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-299-000 EDWARD SOUTHERLAND D.B. 5571, PG. 1535 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-298-000 ANNA ROVETTO D.B. 6636, PG. 1714 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-297-000 ROCHELLE KREINER D.B. 6406, PG. 1314 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-296-000 CAMERON DANIEL D.B. 6290, PG. 242 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-295-000 RICHARD WILSON D.B. 5545, PG. 2050 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-011-000 PORTERS CROSSING HOA INC D.B. 6102, PG. 2894 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL AMENITY R03700-004-293-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL COMMUNITY OPEN SPACE WETWETWET WETWET WE T W E T W E T WETWET W E T WET WET W E T WE T WE T W E T WE T WE T 20 ' W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W SSSSSSSSSSSSSSSSSS WWWWWWWWWWWW W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSS W W W WWWWWWWWWWWWWWWWWWWWWWWWWW SS X X X X XX SU P - R - 1 5 Z O N I N G S I T E P L A N C-2.2 12 . 0 2 . 2 4 1" = 6 0 ' AH E AH E RP B VICINITY MAP NOT TO SCALE NORTH 140 SITE MAR K E T S T MA R S H RE A C H D R F O L L Y I S L A N D C T OA K S POR T E R S C R O S S I N G W A Y M A R S H DR P O R T E R S N E C K R D F U T C H C R E E K R D B A Y F I E L D D R 0 30 60 120 240 SCALE: 1"=60' GRAPHIC SCALEGRAPHIC SCALE BA Y S H O R E T O W N H O M E S NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 24237.PE BA Y S H O R E T O W N H O M E S , L L C 20 1 N O R T H E L M S T R E E T , S U I T E 2 0 1 GR E E N S B O R O , N C 2 7 4 0 1 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL AP P L I C A N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 PR E L I M I N A R Y D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N 2 6 7 8 9 10 1A 38 36 45 1B 3 21 21 22 23 24 25 26 28 29 31 32 33 34 34 37 39 39 41 42 44 47 50 49 52 52 52 52 23 22 24 SITE DATA PROJECT ADDRESSES: PROPERTY OWNERS:BEE SAFE PORTERS NECK, LLC, HERBERT E PARHAM, AND B-2 PARCEL PINS: R03600-005-007-000 (± 2.82 AC) R03600-005-006-002 (± 0.39 AC) R-15 PARCEL PINS: R03700-004-147-000 (± 20.41 AC) R03700-004-148-000 (± 2.12 AC) R03700-004-189-000 (± 7.79 AC) ROAD CONNECTION PARCEL (NOT INCLUDED IN SUP REQUESTS): PROPERTY OWNER: ROBERT L YUNASKA R03600-006-082-000 (I-1 ZONING, ±0.02 AC) PROPOSED USE:MIXED-USE COMMERCIAL/RETAIL & RESIDENTIAL MULTI-FAMILY, TOWNHOME (ROWHOUSE) RESIDENTIAL FUTURE LAND USE CLASSIFICATION:URBAN MIXED USE, GENERAL RESIDENTIAL, GROWTH NODE TOTAL PROJECT SITE AREA:± 33.43 AC CURRENT ZONING: B-2 (±3.21 AC) & R-15 (±30.22 AC INCLUDING ± 1.30 AC IN COD) PROPOSED ZONING: SUP - B-2 MIXED USE & SUP- R-15 ADDITIONAL DWELLING ALLOWANCE DENSITY:SUP - B-2 MIXED USE B-2 DENSITY DENSITY ALLOWED: NO MAX. OR MIN. IDENTIFIED IN UDO DENSITY PROPOSED:B-2 DENSITY: 19.31 DU/AC SUP- R-15 ADDITIONAL DWELLING ALLOWANCE HIGH DENSITY RESIDENTIAL DENSITY ALLOWED:10.2 DU/AC PROPOSED DENSITY: 8.37 DU/AC EXCLUDING COD AREA 8.0 DU/AC INCLUDING COD AREA MAXIMUM TOTAL PROPOSED UNITS:304 TOTAL UNITS + RETAIL SPACE 242 TOWNHOMES (R-15) 62 APARTMENT UNITS (B-2) 1,800 SF RETAIL MAX. (B-2) SITE DEVELOPMENT NOTES: R-15 SUP DESIGN REQUIREMENTS: IMPERVIOUS SURFACE ALLOWED: 40% MAX. IMPERVIOUS SURFACE PROVIDED:40% MAX. OPEN SPACE REQUIRED:35% OPEN SPACE PROVIDED:MEET OR EXCEED 35% MINIMUM PARKING REQUIREMENTS - R-15 DWELLING, ROW-STYLE (TOWNHOMES) 2 SPACES REQUIRED PER DWELLING UNIT TOWNHOME PARKING REQUIRED:484 SPACES MINIMUM TOWNHOME PARKING PROVIDED:484 SPACES MINIMUM BUILDING DIMENSIONAL REQUIREMENTS BUILDING HEIGHT: 40' MAX HT BUILDING SETBACK: EXCEEDS 20' SINGLE FAMILY AND 30' MULTI-FAMILY SETBACKS GENERAL NOTES: 1.THE PROPOSED DEVELOPMENT SHALL MEET OR EXCEED ALL NEW HANOVER COUNTY (NHC) ORDINANCE AND PERMIT REQUIREMENTS. 2.IF THE SUP IS GRANTED, THE B-2 AND R-15 PORTIONS OF THE SITE WILL BE CONSTRUCTED AS A COHESIVELY DESIGNED. PERMITTED, CONSTRUCTED, AND MAINTAINED. 3.THE HATCHED I-1 ZONED PROPERTY LOCATED BETWEEN THE B-2 AND R-15 SITE SHALL PROVIDE VEHICULAR, PEDESTRIAN, AND UTILITY ACCESS FOR ALL PARCELS WITHIN THE DEVELOPMENT BOUNDARY. 4.THE DEVELOPMENT SHALL HAVE A HOA / POA IF / AS APPLICABLE. 5.STORM WATER SHALL BE DESIGNED AND PERMITTED IN ACCORDANCE WITH ALL NEW HANOVER COUNTY AND STATE REQUIREMENTS. 6.PUBLIC WATER AND SEWER WILL BE EXTENDED BY THE DEVELOPER TO THE SITE. ALL DESIGN AND PERMITTING SHALL BE COORDINATED WITH CFPUA, NEW HANOVER COUNTY, AND STATE REGULATORS AS REQUIRED. 7.ALL LANDSCAPE & BUFFER MATERIALS AND INSTALLATION SHALL MEET OR EXCEED NHC UDO REQUIREMENTS. 8.LOCATIONS OF ALL AMENITY AND RECREATION AREAS MAY CHANGE PENDING FINAL DESIGN 9.EXISTING TREES PROPOSED FOR PRESERVATION, BUT WILL BE FURTHER EVALUATED WITH FINAL DESIGN; TREE MITIGATION WILL BE REVIEWED WITH PART OF TREE REMOVAL PERMIT. BR A Y S D R I V E 52 ' P U B L I C R / W SHAC K L E F O R D D R I V E 52' PU B L I C R / W 51 43A 3 41 4 35 34 34 34 43 48 52 30 56 58 59 60 63 SANITARY SEWER SERVICE (SEE UTILITY PLAN) SEWER CLEANOUT (SEE UTILITY PLAN) STORM PIPE (SEE GRADING & DRAINAGE PLAN) STORM STRUCTURE (SEE GRADING & DRAINAGE PLAN) STORMWATER POND STORMWATER OUTFALL LEVEL SPREADER EMERGENCY STORMWATER OUTFALL EXISTING NON-WETLAND WATERS OF THE US WETLAND IMPACTED FOR ROAD CROSSING WETLANDS PER APPROVED USACE AJD WETLAND DELINEATION DATED 08/26/2024 EXISTING POND IDENTIFIED AS "NATURAL POND" CONSERVATION AREA IN NHC UDO. POND TO REMAIN AND HAVE COD BUFFER SWALE PROVIDING OUTFALL DRAINAGE FOR EXISTING POND 20' WIDE DRAINAGE EASEMENT IN I-1 PARCEL ROAD CONNECTION BETWEEN B-2 AND R-15 PARCELS ALL NECESSARY UTILITY AND STORMWATER EASEMENTS CONVEYED BETWEEN B-2 AND R-15 PARCELS LOCATED ALONG ROAD I-1 PARCEL ROAD CONNECTION BETWEEN B-2 AND R-15 PARCELS MAINTENANCE BUILDING 16 17 18 20 21 22 23 24 25 26 27 28 29 30 19 MINIMUM R-15 REQUIRED BUILDING SETBACK TO ADJACENT RESIDENTIAL 25' MINIMUM REQUIRED BUILDING SETBACK IN B-2 DISTRICT BUILDING SETBACKS EXCEED MINIMUM REQUIREMENT IN ALL LOCATIONS CLUBHOUSE / PROPERTY MANAGEMENT OFFICE / FITNESS / RECREATION CENTER FENCED POOL W/ SUMMER KITCHEN AND CABANA(S) BUILDING LANDSCAPE AREA FOUNDATION PLANTINGS AROUND ALL BUILDINGS, TYP. SEGMENTAL RETAINING WALL 4" HIGH CONCRETE WHEELSTOP STREET LIGHT, TYP. NATURE TRAIL EXISTING VEGETATION / LANDSCAPE BUFFER COMBINATION OF EXISTING & PLANTED VEGETATION CREATING BUFFER TO ADJACENT PROPERTIES; BUFFERS EXCEED MINIMUM BUFFER REQUIRED MINIMUM BUFFER LINE PROPOSED LANDSCAPE STREET TREES ALONG ALL PROJECT ROADS AND IN LANDSCAPE ISLANDS 32 33 34 3536 38 31 TRASH & RECYCLING COMPACTOR W/ SCREEN MONUMENT SIGN EMERGENCY-ONLY GATED ACCESS GATED ACCESS FOR EMERGENCY VEHICLES EQUIPPED WITH KNOX BOX/LOCK. ALIGN PAVING WITH BRAYS DRIVE 41 45 46 50 51 37 39 4735 48 40 49 52 EXISTING 30' DUKE ENERGY PROGRESS, LLC EASEMENT TO BE RELOCATED, PENDING DUKE APPROVAL EXISTING 30' PUBLIC UTILITY EASEMENT EXISTING 15' DRAINAGE & PUBLIC UTILITY EASEMENT EXISTING 30' SANITARY SEWER EASEMENT EXISTING 30' DRAINAGE & PUBLIC UTILITY EASEMENT 54 55 53 KEY LEGEND: 1A HEAVY DUTY ASPHALT PAVING, TYP. (SEE DETAILS) LIGHT DUTY ASPHALT PAVING, TYP. (SEE DETAILS) CURB AND GUTTER VERTICAL CURB CONCRETE SIDEWALK INTERCONNECTED SIDEWALK,TRAIL SYSTEM THROUGHOUT PROJECT ADA CURB RAMP WITH TRUNCATED DOMES WARNING MAT SPECIMEN LIVE OAK CLUSTER PRESERVED PEDESTRIAN CROSSING LOCATION PARKING LOT STRIPING ADA PARKING SPACE (TYP) 2 4 5 6 7 8 1B 3 10 11 12 9 13 14 15 ADA LOADING SPACE (TYP) ADA PARKING SPACE SIGNAGE (TYP) WATER MAIN (SEE UTILITY PLAN) WATER SERVICE (DOMESTIC) (SEE UTILITY PLAN) WATER SERVICE (FIRE) (SEE UTILITY PLAN) WATER METER (SEE UTILITY PLAN) FIRE HYDRANT (SEE UTILITY PLAN) SANITARY SEWER MAIN (SEE UTILITY PLAN) 57 58 56 60 61 59 EXISTING 20' UTILITY EASEMENT EXISTING 20' DRAINAGE & UTILITY EASEMENT COMMERCIAL SPACE BETWEEN 1700 SF AND 1800 SF MIXED USE BUILDING 63 EXISTING TREE, TYP. PICKLEBALL COURTS SEE GENERAL NOTES OPEN SPACE, TYP. DOG PARK SEE GENERAL NOTES MOTOR COURT, TYP. RESIDENTS' PARKING AT CORE OF EACH BLOCK BEHIND UNITS. GARAGE ACCESS PROVIDED IN MOTOR COURT STREETYARD 25' MINIMUM REQUIRED 50' MAXIMUM SHOD PARKING SETBACK 100' MAXIMUM SHOD BUILDING SETBACK EXISTING 40' DRAINAGE & PUBLIC UTILITY EASEMENT MULTI-FAMILY BUILDING ALL RESIDENTIAL APARTMENTS 3-STORY ROW STYLE TOWNHOME WITH IN-UNIT GARAGE, TYP. 2-STORY END-UNIT ROW STYLE TOWNHOME, NO GARAGE, TYP. 42 43 44 43A 64 65 66 67 68 62 27 43 67 68 43 20 20 17 16 15 6867 4443 43A 43A 56 1B 44 43A 34 33 Planning Board - January 9, 2025 ITEM: 1 - 14 - 5 SU P - B - 2 Z O N I N G D R A I N A G E P L A N C-3.1 12 . 0 2 . 2 4 1" = 5 0 ' RP B RP B RP B VICINITY MAP NOT TO SCALE NORTH 140 SITE MAR K E T S T MA R S H RE A C H D R F O L L Y I S L A N D C T OA K S POR T E R S C R O S S I N G W A Y M A R S H DR P O R T E R S N E C K R D F U T C H C R E E K R D B A Y F I E L D D R 0 25 50 100 200 SCALE: 1"=50' GRAPHIC SCALEGRAPHIC SCALE BA Y S H O R E T O W N H O M E S NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 24237.PE BA Y S H O R E T O W N H O M E S , L L C 20 1 N O R T H E L M S T R E E T , S U I T E 2 0 1 GR E E N S B O R O , N C 2 7 4 0 1 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL AP P L I C A N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 PR E L I M I N A R Y D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N US H W Y . 1 7 - M A R K E T S T R E E T 10 0 ' P U B L I C R / W PROPOSED SEGMENTAL RETAINING WALL PROPOSED DROP INLET PROPOSED STORM SEWER COLLECTION SYSTEM LEGEND: EXISTING CONTOUR PROPOSED CONTOUR EXISTING SPOT ELEVATION PROPOSED EDGE OF PAVEMENT PROPOSED SIDEWALK ELEVATION PROPOSED GRADE PROPOSED TOP OF WALL PROPOSED TOP OF CONCRETE 16 EG 25.05 EP 25.05 SW 25.05 LOD PG 25.05 TW 25.05 TC 17.15 16 STORMWATER NOTES: 1.ALL ON-SITE PROPOSED IMPERVIOUS SURFACES WILL DRAIN TO ONE OF THE TWO (2) PROPOSED STORMWATER WET PONDS. THESE PONDS ARE DESIGNED IN ACCORDANCE WITH NCDEQ AND NHC STORMWATER ORDINANCE. ALL RUNOFF WILL BE COLLECTED AND CONVEYED BY A CLOSED CONDUIT SYSTEM TO THE WET DETENTION BASINS. BUILDING PAD NOTE: 1.SITE CONTRACTOR SHALL STRIP TOPSOIL AND ANY UNSUITALBE MATERIAL AND PROVIDE CUT/FILL OPERATIONS TO PROVIDE A COMPACTED CONTROLLED BUILDING PAD, IN ACCORDANCE WITH SUBSURFACE GEOTECHNICAL EXPLORATION AND/OR TECHNICAL SPECIFICATIONS. ASPHALT AREA NOTE: 1.SITE CONTRACTOR SHALL STRIP TOPSOIL AND ANY UNSUITALBE MATERIAL AND PROVIDE CUT/FILL OPERATIONS TO PROVIDE A COMPACTED CONTROLLED SUBGRADE, IN ACCORDANCE WITH THE SUBSURFACE GEOTECHNICAL EXPLORATION AND/OR TECHNICAL SPECIFICATIONS. GENERAL NOTES: 1.ALL CONSTRUCTION TO BE IN ACCORDANCE WITH ALL STATE OF NC, NEW HANOVER COUNTY, AND CFPUA STANDARDS AND SPECIFICATIONS. 2.THE CONTRACTOR SHALL PLACE INLET PROTECTION AROUND ALL STORM DRAIN INLETS TO PROTECT THE SYSTEM FROM COLLECTING SEDIMENTATION DURING CONSTRUCTION. INLET PROTECTION SHALL REMAIN IN PLACE UNTIL THE ROADS ARE PAVED. 3.CONTRACTOR SHALL ADJUST ALL FRAMES OF EX. UTILITY INFRASTRUCTURE WITHIN ASPHALT OVERLAY, NEW ASPHALT AREAS, AND SIDEWALKS TO MATCH PROPOSED GRADES. 4.ALL PROPOSED SPOT ELEVATIONS SHOWN ARE PROPOSED EDGE OF PAVEMENT UNLESS NOTED OTHERWISE. 5.CONNECT ROOF DRAINS AS SHOWN. IF THERE ARE ANY DRAINAGE QUESTIONS, PLEASE NOTIFY OWNER AND ENGINEER PRIOR TO MAKING CONNECTIONS. 6.ALL SIDEWALK CROSS SLOPES HAVE BEEN GRADED TO MEET ADA REGULATIONS. CONTRACTOR SHALL CONFIRM GRADES BEFORE PLACING PAVEMENT OR SIDEWALKS AND REPORT ANY DISCREPANCIES TO OWNER AND/OR ENGINEER. 7.CONTRACTOR SHALL REFER TO THE GEOTECHNICAL ENGINEERING REPORT FOR SITE CONSTRUCTION RECOMMENDATIONS. 8.CONTRACTOR SHALL STAKE SILT FENCE ALONG LIMITS OF DISTURBANCE LINE. THE SILT FENCE LINE TYPE IS OFFSET ON THE DRAWING FOR CLARITY. 9.THE CONTRACTOR SHALL USE EITHER RCP (CL. III) OR ADS HP STORM PIPE FOR THE STORM DRAINAGE SYSTEM. IF THE CONTRACTOR CHOOSES TO USE HP STORM PIPE, IT SHALL BE ADS N-12 WT STORM PIPE OR APPROVED EQUAL AND SHALL BE INSTALLED TO MANUFACTURER SPECIFICATIONS. IN ADDITION, THE CONTRACTOR SHALL BE SURE TO PROVIDE CONCRETE COLLARS AROUND EACH F.E.S. TO PREVENT FLOATATION IF HP STORM PIPE IS CHOSEN. IF HP STORM PIPE IS CHOSEN, ALL PIPING WITHIN THE PUBLIC RIGHT OF WAY MUST BE DUAL WALL HP-PIPE (GRAY) NOTATION: CI =CURB INLET DI =DROP INLET CO =CLEANOUT DDI =DOUBLE DROP INLET MH =STORM DRAIN MANHOLE RD =ROOF DRAIN CLEANOUT FFE =FINISHED FLOOR ELEVATION BPE =BUILDING PAD ELEVATION DS =DOWNSPOUT LIMITS OF DISTURBANCE SILT FENCE TREE PROTECTION FENCING DRAINAGE FLOW PATH DRAINAGE INLET LABEL INLET PROTECTION EXISTING REGULATED TREE BY NHC AS-BUILT STORMWATER NOTE [15A NCAC 02H.1044]: 1.)THE CONTRACTOR WILL EMPLOY A LAND SURVEYOR LICENSED IN THE STATE OF NORTH CAROLINA TO PROVIDE ACCURATE REPRODUCIBLE AS-BUILT DRAWINGS OF NEWLY INSTALLED COLLECTION SYSTEM, AND IMPERVIOUS AREA ON THE SITE TO THE ENGINEER & OWNER UPON COMPLETION OF CONSTRUCTION. UPON CERTIFICATION BY THE ENGINEER AND VERIFICATION FROM THE OWNER ANY DISCREPANCIES WILL BE INDICATED, THEN THESE PLANS SHALL BE RETURNED TO THE CONTRACTOR FOR CORRECTION PRIOR TO FINAL PAYMENT AND FINAL INSPECTION. CO-1 SPECIAL USE PERMIT GENERAL NOTES: 1.THE PROPOSED DEVELOPMENT SHALL MEET OR EXCEED ALL NEW HANOVER COUNTY (NHC) ORDINANCE AND PERMIT REQUIREMENTS. 2.STORM WATER SHALL BE DESIGNED AND PERMITTED IN ACCORDANCE WITH ALL NEW HANOVER COUNTY AND STATE REQUIREMENTS. 3.PUBLIC WATER AND SEWER WILL BE EXTENDED BY THE DEVELOPER TO THE SITE. ALL DESIGN AND PERMITTING SHALL BE COORDINATED WITH CFPUA, NEW HANOVER COUNTY, AND STATE REGULATORS AS REQUIRED. 4.ALL LANDSCAPE & BUFFER MATERIALS AND INSTALLATION SHALL MEET OR EXCEED NHC UDO REQUIREMENTS. 5.ACCESS EASEMENTS WILL BE GRANTED FROM A PUBLIC ROAD TO EACH BMP FOR NHC ACCESS. PROPOSED LIMITS OF DISTURBANCE (TYP.) PROPOSED SILT FENCE (TYP.) PROPOSED LIMITS OF DISTURBANCE (TYP.) PROPOSED SILT FENCE (TYP.) PROPOSED TREE PROTECTION FENCING (TYP.) BRA Y S D R I V E PROPOSED INLET PROTECTION (TYP.) PROPOSED STORMWATER WET POND DU K E E N E R G Y P R O G R E S S , L L C EA S E M E N T DB 6 0 9 6 , P G 1 2 8 8 CA R O L I N A P O W E R & L I G H T C O M P A N Y DB 6 7 2 P G 1 7 7 50 ' F R O N T S E T B A C K LOT 142 R03600-006-012-000 RICHARD MOBURG ELIZABETH MOBURG D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL R03600-006-082-000 ROBERT L. YUNASKA D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: I-1 LAND USE: VACANT INDUSTRIAL R03600-005-008-000 GREGORY POOLE EQUIPMENT COMPANY D.B. 6645, PG. 1746 ZONING: B-2 LAND USE: COMMERCIAL R03600-005-005-000 SANDERS FAMILY STORAGE, LLC D.B. 6001, PG. 1677 ZONING: B-2 LAND USE: COMMERCIAL STORAGE SW E E T W A T E R B R A N C H 46 46 45 45 45 45 44 4 4 44 43 43 43 42 4 2 42 41 41 40 39 38 37 36 35 34 33 33 32 32 32 32 31 31 31 31 30 30 30 30 29 29 29 29 29 29 28 28 28 28 27 27 27 27 27 27 27 27 27 27 27 27 26 26 26 26 20 ' SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W SSSSSSSSSSSS WWWWWWWW W W W W W W 41 40 3539383736 35 34 33 33 424344 20 22 23 24 25 21 26 27 27 28 191817161514 13 12 112727262524232221 20 19 18 17 16 15 14 13 27 26 TC 39.93 EP 39.39 TC 33.44 EP 32.90 TC 33.72 EP 33.18 TC 26.84 EP 26.30 FFE=28.20 FF E = 2 8 . 6 0 FF E = 2 8 . 9 2 FFE=28.67 DI 26.38 PG 26.63 DI 26.75PG 27.85 PG 27.85 PG 27.80 PG 27.85 PG 27.85 PG 27.85 PG 27.85 DI 25.92 SW 27.70SW 27.61 SW 27.42 PG 27.13 SW 27.53 PG 26.13 PG 26.33 PG 26.63 PG 26.98 DI 25.98DI 26.59PG 27.09DI 26.59PG 27.59 DI 27.78 DI 26.76PG 28.10 DI 27.44 PG 27.91 DI 27.56 PG 28.80 PG 28.30 PG 28.08 PG 28.80 PG 28.08 PG 28.55 DI 25.75PG 26.42DI 25.57 PG 27.51DI 29.27 PG 32.03 DI 31.24 DI 31.92 PG 32.78 PG 34.08 DI 33.28 PG 34.47 DI 36.88 DI 32.43 PG 33.29PG 34.08 PG 31.39 PG 31.60 PG 32.32 TC 32.80 EP 32.26 TC 34.77 EP 34.23 TC 31.92 EP 31.38 FFE=34.00 FFE=36.00 DI 40.03 PG 38.35PG 39.19 PG 36.42DI 38.53 PG 40.31 DI 41.19 EG 46.33 PG 44.06 PG 34.71 PG 42.20 PG 41.71 FF E = 4 2 . 5 0 PG 34.19 FFE=35.25 TW 44.75 PG 44.00 TW 44.00 PG 38.25 TW 40.75 PG 35.25 TW 37.50 PG 35.00 TW 37.00 PG 33.75 TW 35.00 PG 34.75 FF E = 2 7 . 8 7 LO D LO D LO D LO D LO D LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LO D LO D LO D LO D LO D LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LO D LO D LO D LO D L O D LO D L O D L O D L O D L O D L O D L O D L O D L O D L O D LOD LOD LOD LOD LOD LOD LOD LODLOD LOD LODLODLODLOD L O D L O D L O D L O D L O D LOD LOD LOD LO D LO D LO D L O D LOD LOD LOD LOD LOD LO D N O N - W E T L A N D W A T E R S O F T H E U S TR I B U T A R Y Planning Board - January 9, 2025 ITEM: 1 - 14 - 6 RIP RIP 22O K 13O K 13O K 18PO 12PN13PN 22PN 22PN 22PN 12O K 15OK 18O K 27O K 15O K 23O K 17O K 16PO 14PO 12PO 16O K 26P N 14O K 15OK 22P N 25P N 13PN 13O K 16O K 13O K 17O K 28PO 13O K 12O K 17O K 15PN 18P N 12O K 18PN 24PN 12O K 14PN 17G M 10SY 9OK 12PN 15P N 20OK 12O K 12HI 18O K 11OK14P N 12PN 12G M 15O K 16P N 20P N 8OK 13HI 23PN 10HI 10H I 13O K 11H I 12P N 4HI 19PN 18P N 8HI 11O K 24P N 20P N 9OK 8GM 12G M 23P N 11OK 10O K 15PN 20PN 26P N 23PN 9GM 23P N 11O K 14O K 15O K 8OK9OK 8OK 13O K 8OK 10O K 13O K 12G M 10G M 23G M 8OK 14P N 10O K 13O K 12O K 21O K 13O K 12O K 13O K 8GM 24OK 12O K 9GM 24O K 12O K 12G M 8GM 26O K 21PN 23G M 13O K 8GM 13GM 22PN 22P N 30P N 16P N 15O K 8GM 16OK 11O K 8OK 17PN 13O K 8OK 12OK 12OK 19O K 13G M 12PN 12O K 14O K 15O K 12GM 13OK 12O K 14PN 14PN 13O K 10O K 54G M 19PN 20PN 16PN 16P N 12PN 19P N 12P N 13PN 17P N 14P N 20PN 18PN 16P N 12PN 17PN12PN 17PN 15PN 17PN 8GM 14G M 6MG 11O K 5AH 16PO 14O K 15O K 14P O 13O K 16OK 12GM 12PN 12O K 12CH 4MM 5CT 4CT 8CT 4CT 4CT4CT 12C T 9CT 13CT 8CT 4MM4MM 4MM4MM CEMETERY LOT 142 R03600-006-012-000 RICHARD MOBURG ELIZABETH MOBURG D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 143 R03600-006-013-000 NORA E. BENEVENTI REVOCABLE TRUST D.B. 5020, PG. 2264 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 144 R03600-006-014-000 DAVID M. RENQUIST MARY E. RENQUIST D.B. 5020, PG. 2264 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 147 R03600-006-017-000 PRUDENTIAL RELOCATION INC. D.B. 5238, PG. 722 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 148 R03600-006-018-000 BRADLEY J. ERBES TAMI L. ERBES D.B. 5238, PG. 722 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 149 R03600-006-024-000 ERNEST W. OLDS DAWN M. OLDS D.B. 6056, PG. 182 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL LOT 150 R03600-006-025-000 RICHARD MIMMS SUPATRA MIMMS D.B. 6221, PG. 2760 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL LOT 151 R03600-006-026-000 MADISON M. NEWSOME BUNJONG P. NEWSOME D.B. 4655, PG. 304 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL R03600-006-082-000 ROBERT L. YUNASKA D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: I-1 LAND USE: VACANT INDUSTRIAL 40' DRAINAGE AND PUBLIC UTILITY EASEMENT D.B. 5053, PG.1637 R0 3 7 0 0 - 0 0 4 - 2 9 3 - 0 0 0 PO R T E R ' S P O I N T E HO M E O W N E R S AS S O C I A T I O N , I N C D. B . 5 7 9 0 , P G . 3 5 M. B . 5 5 , P G . 3 4 0 18' PRIVATE ALLEY R03700-004-293-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL COMMUNITY OPEN SPACE R03700-004-294-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL AMENITY R03705-006-007-000 KATHRYN WOLFE & LARRY STEVEN MORGAN D.B. 6025, PG. 1493 M.B. 46, PG. 25 ZONING: R-15 LAND USE: RESIDENTIAL R03705-006-012-000 JOANN M. WAINIO D.B. 5694, PG. 1838 M.B. 46, PG. 25 ZONING: R-15 LAND USE: RESIDENTIAL 30' SANITARY SEWER EASEMENT M.B. 46, PG. 25 L O T 4 8 R 0 3 7 0 0 - 0 0 4 - 2 7 9 - 0 0 0 J O R Y A N D E R S O N & A B B Y R I C H O M N D D. B . 6 6 7 5 , P G . 1 3 2 7 M . B . 5 5 , P G . 3 4 0 Z O N I N G : R - 1 5 L A N D U S E : R E S I D E N T I A L BUILDING R0 3 7 0 0 - 0 0 4 - 1 9 1 - 0 0 0 PO R T E R S C R O S S I N G HO A I N C D. B . 5 1 9 0 , P G . 1 2 0 4 M. B . 5 1 , P G . 1 5 4 ZO N I N G : R - 1 5 LA N D U S E : RE S I D E N T I A L A M E N I T Y R03700-004-301-000 DEREK REEVES D.B. 5625, PG. 1573 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-300-000 STEVE LINDNER D.B. 6031, PG. 2140 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-299-000 EDWARD SOUTHERLAND D.B. 5571, PG. 1535 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-298-000 ANNA ROVETTO D.B. 6636, PG. 1714 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-297-000 ROCHELLE KREINER D.B. 6406, PG. 1314 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-296-000 CAMERON DANIEL D.B. 6290, PG. 242 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-295-000 RICHARD WILSON D.B. 5545, PG. 2050 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-011-000 PORTERS CROSSING HOA INC D.B. 6102, PG. 2894 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL AMENITY 15 ' D R A I N A G E A N D P U B L I C UT I L I T Y E A S E M E N T M. B . 5 1 , P G . 1 5 4 30 ' D R A I N A G E & U T I L I T Y E A S E M E N T 30' PUBLIC UTI L I T Y E A S E M E N T M.B. 51, PG. 15 4 20' DRAINAGE AND PUBLIC UTILITY EASEMENT M.B. 51, PG. 154 10O K 19PN 18O K 19O K 11OK 11O K 12O K 10O K 12P N 10O K 12O K 24PN 17O K 11O K 10O K 18PN 20PN 20PN 12OK 17P N 19PN 12PN21P N 14P N 14PN 14P N 12PN 13P N18PN 19PN 15O K 13P N 16O K 15P N 18PN 18P N 20PN 18P N 15PN 8HI 17PN 18PN16P N 19PN 19PN 13O K 15O K15O K8OK 12O K 18PN 19P N 17P N 18P N 16PN 14PN 16P N 12PN 15P N 13PN 12P N 15P N 13PN 14PN 20PN 20O K 14P N 15P N 15P N 13P N 12OK 8OK 8OK 4CM 9OK 6MG 5MG 13G M 13PN 11O K 15O K 18PN 9OK 17PN 8OK 8OK 12OK 15P N 9OK 15PN 9OK 8OK 9OK 12P N 15P N 11O K 8DW 18PN 14P N 12O K 13PN 8OK 13P N12PN 8MA 16P N 5AH9OK18P N 9OK 9OK 15P N 12PN 5MG 13P N 5MG 8GM 16P N 9GM 14PN 12PN 8OK 8GM 8GM 14PN 22PN 8OK 10O K 10GM 8OK 8OK 18P N 13PN 9GM 13P N 14PN 8OK 14PN 14P N 17P N 10G M 8OK 13PN 12PN 7CM 22OK 9GM 21PN 28P N9OK 19PN 11OK 4MG 13O K 17PN 10O K 15P N 16P N 16PN 16P N 13PN 9OK 18PN 18O K 14OK 13O K 23O K 13O K 15O K 15O K 15OK 14O K 15O K 12O K 21O K 28O K 30PN 19O K 18P N 24PN 21PN 26PN 12O K 15O K 25O K 15O K 15O K 15O K 22OK 19P N 14O K 12O K 17P N 13PN 15P N 14PN 17O K 14OK 23O K 23P N 19PN 15OK8DW 9OK 14O K 23PN 31PN 28P N 35PN 19P N 15P N 17O K 16PN 14PN 12CH 15PN 8OK 8OK 14O K 19O K 24PN 22P N 12O K 13OK 13OK 12O K 14PN 15P N 15PN 21PN 21PN 14OK8OK 14PN 18O K 24PN 18O K 18O K 17PN 16PN 25O K 8DW 15O K 18O K 7DW 7DW 7DW 7MG 11O K 18O K 11O K 9DW 7DW 15O K 13O K 19PN 19PN 20O K 18PN 13P N 14PN 23P N 15P N 13OK 21PN 27PN 30PN 12M A 19P N 14PN 20PN 12P N 10PA 10PA 14PA 15P A 10PA 10P A 8PA 8PA 15PN17PN 16P N 12O K 17O K 12O K 13O K 16P N 12PN 15PN 18PN 18PN 24PN 19P N 20P N 24PN 21P N 15O K 21PN 15OK 18O K 12O K 14O K 13PN 25PN12PN 24PN 20PN 14P N 12PN 14P N 9OK 13P N 24PN 14PN 10O K 12PN 4AH 15PN 23PN 18O K 22O K 15OK 13O K 12O K 9OK 14O K 18O K 8PA 10G M 10G M 10G M 12PO12P O 8PO 11G M 13G M8GM 12PN 10O K 14O K 13O K 8OK 18O K 27O K 12O K 13G M 8PO 12PO 12P O 10G M 18O K 10G M 17O K 14GM 10O K 14O K 8GM 12OK 13G M 10G M 13O K 8OK 10G M 18P N 15PN 15PN 13O K 23P N 12C H 14P N 12PN 8OK 8OK 20PN 19P N 9GM 22P N 19PN 13P N 18PN 18P N 12PN 8OK19P N 8OK 8OK 5CT 14P N 20O K 10O K 16O K 16O K 18P N 8OK 18PN 10O K 17P N 14PN 17P N 14PN 17P N 17O K 20PN 17C E12PN 13PN 24PN 18O K 21PN 4CM4CM 22O K 15PN 12PN 21PN 10G M 13PN 12PN 14PN 12P N 14PN 17PN 12PN 14P N 14P N 12P N 21O K 20O K21O K 18OK 23O K 15O K 15O K 24O K 29OK 24PN 20PN 30O K 22P N 17O K 13O K 19PN 25O K 28P N 15O K 20O K 19PN 25P N 35O K 35O K25O K 32O K 39PN 20P N 8PA 12P N 30PN 24P N 4SY 19P N 8OK 14P N 14PN 9GM 11G M 8GM 11G M12PN 17PN 12PN 13O K 13OK 13OK 18P N 17P N 9PN 15PN 19P N 15PN 14PN 18P N 14P N 15P N 8OK9OK 15PN 10O K 5DW 20PN 11O K 20PN 20PO 24O K 24PN 15O K 19OK 18O K 8MG 6MG 13O K 8MG 11O K 15P N13O K 15O K 14OK 19O K 15O K 16O K 15O K 24P N 15P N 12O K 26O K 13O K 18P N 14O K 14G M 23PN 15O K 24P N 7MG 8OK 21O K 12O K 16O K 24O K 28O K 14PA 10PA 10PA 4PA 10PA 5MM 9OK 11G M 14P N 17P N 36O K 24O K 22OK 9OK 12P N 12P N 4PR 4PR 18OK 23P N 20P N 26OK 19O K 23O K 19O K 18O K 12O K 15P N 17P N 15P N 18P N 17PN 15G M 20P N 24PN 4EL 24O K 7MG10O K 8OK 9OK 12G M 14PN 13PN 12P N 17PN 21P N 18O K 10O K 21PN 20PN8OK4MG 6MG 14O K10O K 10OK 18P N 12OK 11O K 16PN 15PN 8OK17PN16PN 23PN 20PN 18P N 15PN 18P N 16PN 4CE 16P N 15PN 13P N 13PN 8OK 12PN 13OK 14PN 8OK 12PN 10O K 12O K 18OK 24PN 14P N 9OK 18O K 27PN 14P N 18PN 17P N 14P N 10G M 13PN 14O K 19PN 12P N 14P N 15P N 12PN 8OK 17O K 17OK12PN 15PN 15PN 12O K 16G M 17O K 4CM 21PN 10GM 22PN 22PN 13O K 21P N 11O K 12O K 9OK 15PN 18PN 12PN 12PN 13P N 19PN 12PN 13P N 4MG 12P N 8OK8MA 15O K 10O K 8OK 17O K 18O K 27O K 20O K 17O K 18O K 21P N 27P N 24O K 15O K 18O K 17O K 28O K 19O K 27O K 19O K 35OK 20PN 24PN 9OK 6DW 5DW 10P N 10O K 14O K 20O K 19PN 23O K 24O K 35O K 17PN 24PN 19PN 22P N 29PN 8PR 10P A 9PA 16PA 23PN 25PN 18PN 18P N 36PN 14PN 17PN 15PN 16PN 14PN 18P N 17PN 20P N 22PN 24PN 16O K 17O K 26G M 17PN 13PN15PN 12P N 13P N 13P N16P N 21PN 13PN 23PN 17PN 13PN 14P N 20PN 13PN 15G M15G M 15PN 18PN 14PN 12P N 20P N 5SY 12PN 11O K 12PN 15P N 13P N 8GM 11O K 10O K 8GM 9OK 13O K 13PN 19PN 14PN 18PN 14PN 8MG 18P N 15PN 13P N 20PN 9OK 13G M 8OK 8GM 13G M 11O K 12PN 15PN 10O K 18PN 15PN 12P N 18PN 10O K 18O K 10O K 9OK 6SY 4MG 15P N 8OK 13G M 8OK 8OK 20PN 15P N 20PN 12PN 10O K 30PN 16O K 10OK 10O K 18O K 12O K 10O K 9PO 26O K 20O K 9OK 15O K 14O K 15G M 14O K 12O K 14O K 30OK 10O K 8GM 30O K 8MA 4AH 7MG 13O K 8PO 11G M 13G M9HI 8OK 13O K 24PN 5MG 14O K 18P O 9GM 10HI 11H I 8OK 26P N 18O K 18PN 11G M 19PN 13P N 19PN 8GM 12M A 19PN 20PN20P N23P O 21P N 20P N 20PN 10SY 13PN 5,4C M ( C L U S T E R ) 21PN 13PN 13OK11G M 23P N 15PA 14P A 15PA 8CH 6MM 10GM 24O K 20PN 12G M 15O K 16O K 14O K 15O K 15O K 15O K 10G M 15O K 22PN 16O K 19P N 16O K 24O K 14PN 12P N 14O K 16PN 8GM 14GM 10G M 9GM 30PN 27P N 17O K 36PN23PN 12P N 25PN 12O K 18P N 12G M14GM 11G M 12O K 14O K 13O K 19O K 16PN 17PN 18PN 13PN 18PN 18P N 17P N 10G M 20PN 27PN 9OK 9GM 10O K 14G M 12O K12O K 12OK 6AH 14O K 29PO 10G M 6AH 17PO 13O K 12O K 13O K 15G M 10O K 12P N 12PN 10G M 13G M 19P N 12G M 14P N 19P N 19P N 15O K9CH 10G M 18P N 21PN 20P N 12G M 5MG 9GM 5MM 18PN 8GM 10O K 9OK 8MA 8GM 8GM 10GM 14GM 8MM 8GM 10G M 10G M 11M A 14PN 9OK 12PN 6PO 20P O 20PO 10O K 5MG 8OK 15P N 8MA 12M A 12C T 9MM 17G M 10O K 15P O 11O K20O K 12P N 24O K 6CT 6CT 8CT 6CT 10O K18P N 12O K 24PN SW E E T W A T E R B R A N C H R03700-004-293-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL COMMUNITY OPEN SPACE 24 23 23 2322 22 22 22 21 21 21 21 21 21 20 20 20 20 20 20 20 20 19 19 19 19 19 19 19 19 19 18 18 18 18 18 18 18 18 18 18 18 17 17 17 17 17 17 17 17 17 17 17 17 17 16 16 16 16 16 16 16 16 16 16 16 16 16 16 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 14 14 14 14 14 14 14 14 14 14 13 13 13 13 13 43 42 41 40 40 39 39 38 38 37 37 36 36 35 35 34 34 34 33 33 33 32 32 32 32 31 31 31 31 31 31 31 30 30 30 30 30 30 30 30 29 29 29 29 29 29 29 29 29 29 29 29 29 2929 29 28 28 28 28 28 28 28 28 28 27 27 27 27 27 27 27 27 2 7 27 27 27 27 27 27 27 27 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 25 25 25 25 25 25 25 25 25 25 25 25 25 25 24 2 4 24 24 24 24 2424 24 24 23 2 3 23 23 23 23 2323 23 23 22 22 22 22 22 2 2 2222 22 21 21 21 19 21 21 21 21 21 20 20 20 20 20 20 20 20 19 19 19 19 18 18 18 17 17 24 21 20 19 18 22 21 222324 26 24 25 26 23 22 21 20 21 22 23 24 25 20 18 18 19 19 26 25 24 23 22 21 24 25 26 23 22 21 2018 17 16 19 15 14 13 12 11 24 25 26 23 22 21 20 12 13 14 11 1516171819 20 1 8 1 7 16 19 15 1 4 1 3 12 11 212223242625 26 25 242322 21 19181716 1514 20 24 25 26 23 22 21 20 12 13 14 11 1516171819 WETWETWET WETWET WE T W E T W E T WETWET W E T WET WET W E T WET W E T W E T WE T WE T 20 ' W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W SSSSSSSSSSSSSSSSSS WWWWWWWWWWWW W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSS W W W WWWWWWWWWWWWWWWWWWWWWWWWWW SS 20 22 23 24 25 21 26 27 27 28 191817161514 13 12 112727262524232221 20 19 18 17 16 15 14 13 27 26 25 24 24 23 21 20 21 20 19 X X X X XX TC 26.77 EP 26.23 TC 26.37 EP 25.83 TC 26.84 EP 26.30 FFE=26.25 FFE=26.25 FF E = 2 6 . 5 0 FF E = 2 6 . 2 5 FF E = 2 6 . 5 0 FF E = 2 6 . 2 5 FFE=26.25 FFE=26.35 FFE=26.75 FF E = 2 6 . 5 0 FF E = 2 6 . 7 5 FF E = 2 6 . 7 5 FF E = 2 7 . 2 5 FFE=28.00 FF E = 2 7 . 5 0 FF E = 2 6 . 9 2 FFE=27.60 FFE=27.17 FFE=28.20 FFE=28.20 FF E = 2 8 . 6 0 FF E = 2 8 . 9 2 FFE=28.67 PG 26.16DI 25.33 DI 25.33 PG 26.16 DI 25.33 DI 25.33 PG 25.45DI 24.95 DI 24.95 PG 25.45 PG 25.45 DI 25.06 PG 25.45DI 24.95 DI 24.95 PG 25.45 PG 25.45 DI 25.06DI 25.06 PG 25.89 DI 26.38 DI 26.38 PG 26.83 DI 26.38 PG 27.06 PG 27.06PG 26.63 DI 26.75PG 27.85 PG 27.85 PG 27.80 PG 27.85 PG 27.85 PG 27.85 PG 27.85 DI 25.92 SW 27.70SW 27.61 SW 27.42 PG 27.13 SW 27.53 PG 25.50 PG 25.45 PG 24.95 PG 25.45 PG 24.95 PG 25.45 PG 24.95 PG 25.45 DI 24.95 PG 25.58 PG 25.63 PG 25.35 PG 26.13 PG 26.33 PG 26.63 PG 26.98 PG 26.38DI 25.98 DI 25.88 PG 26.38 PG 26.22 DI 26.59PG 27.09DI 26.59PG 27.59 PG 26.38 DI 26.01 DI 26.61PG 27.11DI 27.47 DI 26.38 PG 27.29 PG 27.01 PG 28.10DI 27.78 PG 28.48 DI 27.78 DI 26.76PG 28.10 DI 26.76 DI 26.98PG 27.50 DI 26.98 PG 27.85 PG 27.04 DI 26.75 PG 26.92 PG 27.15 DI 27.39PG 27.88 DI 27.39PG 28.14 DI 27.88PG 28.48DI 28.12 PG 29.89 DI 25.91 DI 25.91 PG 26.56 DI 25.91 PG 26.41 PG 26.56 PG 26.02 DI 25.52 PG 25.87 DI 25.52 PG 26.08 DI 26.07 PG 26.62 PG 26.22 DI 25.72DI 25.72PG 26.22DI 25.72 PG 26.68 PG 26.96 PG 26.22 DI 25.45 DI 24.78 PG 25.12 PG 25.62 PG 25.12PG 25.12PG 25.65 PG 25.62 PG 25.18 PG 24.68PG 25.18 PG 24.68 PG 25.18PG 24.68 PG 24.68 PG 25.18 PG 25.80 PG 25.58 PG 26.65 DI 26.20PG 26.65DI 26.35 DI 26.20 PG 27.13 DI 25.97 PG 26.63 DI 25.97 PG 26.38 PG 26.13 DI 25.27 PG 25.60 PG 25.10 PG 25.10 PG 25.60 PG 25.27 PG 25.80 PG 26.38 DI 25.88 PG 26.13 DI 25.88 DI 25.63 PG 26.13 DI 25.97 PG 26.13 DI 25.97 PG 26.38 PG 26.13 DI 25.27 PG 28.64 DI 28.12 DI 27.44 PG 27.91 DI 27.56 PG 27.74 DI 27.30 PG 28.16DI 27.75 PG 27.64 DI 28.36 PG 28.73 PG 28.80 PG 28.30 PG 28.08 PG 28.80 PG 28.08 PG 28.55 PG 28.55 DI 25.75PG 26.42DI 25.57 PG 27.51 PG 31.60 PG 15.00 PG 12.00 DI 25.13 PG 25.63 DI 25.13 PG 25.63 FFE=26.25FFE=26.25 FF E = 2 7 . 8 7 LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LO D LODLOD L O D L O D L O D LO D LODLODLOD LO D LODLODLODLODLODLODLODLODLODLODLODLODLODLOD L O D LOD LO D LO D LO D LO D LOD LODLOD LO D LO D LO D LO D LO D LO D LOD LOD LOD LO D LO D LOD L O D L O D L O D L O D L O D L O D L O D L O D L O D LOD LOD LOD LOD LOD LOD LOD LOD LOD L O D LODL O D LOD LODLOD LOD LODLODLOD L O D L O D L O D L O D LOD LOD LOD LO D LOD LOD LO D LOD LOD LOD L O D LOD LOD LO D LOD L O D L O D L O D L O D LO D LOD LOD LOD LOD LOD L O D L O D L O D LO D LOD LOD LOD LO D NO N - W E T L A N D WA T E R S O F T H E U S TRI B U T A R Y SU P - R - 1 5 Z O N I N G D R A I N A G E P L A N C-3.2 12 . 0 2 . 2 4 1" = 6 0 ' RP B RP B RP B VICINITY MAP NOT TO SCALE NORTH 140 SITE MAR K E T S T MA R S H RE A C H D R F O L L Y I S L A N D C T OA K S POR T E R S C R O S S I N G W A Y M A R S H DR P O R T E R S N E C K R D F U T C H C R E E K R D B A Y F I E L D D R 0 30 60 120 240 SCALE: 1"=60' GRAPHIC SCALEGRAPHIC SCALE BA Y S H O R E T O W N H O M E S NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 24237.PE BA Y S H O R E T O W N H O M E S , L L C 20 1 N O R T H E L M S T R E E T , S U I T E 2 0 1 GR E E N S B O R O , N C 2 7 4 0 1 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL AP P L I C A N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 PR E L I M I N A R Y D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N BR A Y S D R I V E 52 ' P U B L I C R / W SHACKL E F O R D D R I V E 52' PUB L I C R / W EXISTING POND PROPOSED DRAINAGE SWALE FOR EXISTING POND PROPOSED STORM WATER COLLECTION SYSTEM (TYP.) PROPOSED STORMWATER WET POND PROPOSED STORMWATER WET POND PROPOSED STORMWATER OUTLET STRUCTURE PROPOSED STORMWATER LEVEL SPREADER PROPOSED STORMWATER OUTLET STRUCTURE PROPOSED STORMWATER LEVEL SPREADER PROPOSED DROP INLET (TYP.) PROPOSED STORM MANHOLE (TYP.) PROPOSED STORM WATER COLLECTION SYSTEM (TYP.) 60' 60' PUBLIC DRAINAGE EASEMENT STORMWATER NOTES: 1.ALL ON-SITE PROPOSED IMPERVIOUS SURFACES WILL DRAIN TO ONE OF THE TWO (2) PROPOSED STORMWATER WET PONDS. THESE PONDS ARE DESIGNED IN ACCORDANCE WITH NCDEQ AND NHC STORMWATER ORDINANCE. ALL RUNOFF WILL BE COLLECTED AND CONVEYED BY A CLOSED CONDUIT SYSTEM TO THE WET DETENTION BASINS. BUILDING PAD NOTE: 1.SITE CONTRACTOR SHALL STRIP TOPSOIL AND ANY UNSUITALBE MATERIAL AND PROVIDE CUT/FILL OPERATIONS TO PROVIDE A COMPACTED CONTROLLED BUILDING PAD, IN ACCORDANCE WITH SUBSURFACE GEOTECHNICAL EXPLORATION AND/OR TECHNICAL SPECIFICATIONS. ASPHALT AREA NOTE: 1.SITE CONTRACTOR SHALL STRIP TOPSOIL AND ANY UNSUITALBE MATERIAL AND PROVIDE CUT/FILL OPERATIONS TO PROVIDE A COMPACTED CONTROLLED SUBGRADE, IN ACCORDANCE WITH THE SUBSURFACE GEOTECHNICAL EXPLORATION AND/OR TECHNICAL SPECIFICATIONS. GENERAL NOTES: 1.ALL CONSTRUCTION TO BE IN ACCORDANCE WITH ALL STATE OF NC, NEW HANOVER COUNTY, AND CFPUA STANDARDS AND SPECIFICATIONS. 2.THE CONTRACTOR SHALL PLACE INLET PROTECTION AROUND ALL STORM DRAIN INLETS TO PROTECT THE SYSTEM FROM COLLECTING SEDIMENTATION DURING CONSTRUCTION. INLET PROTECTION SHALL REMAIN IN PLACE UNTIL THE ROADS ARE PAVED. 3.CONTRACTOR SHALL ADJUST ALL FRAMES OF EX. UTILITY INFRASTRUCTURE WITHIN ASPHALT OVERLAY, NEW ASPHALT AREAS, AND SIDEWALKS TO MATCH PROPOSED GRADES. 4.ALL PROPOSED SPOT ELEVATIONS SHOWN ARE PROPOSED EDGE OF PAVEMENT UNLESS NOTED OTHERWISE. 5.CONNECT ROOF DRAINS AS SHOWN. IF THERE ARE ANY DRAINAGE QUESTIONS, PLEASE NOTIFY OWNER AND ENGINEER PRIOR TO MAKING CONNECTIONS. 6.ALL SIDEWALK CROSS SLOPES HAVE BEEN GRADED TO MEET ADA REGULATIONS. CONTRACTOR SHALL CONFIRM GRADES BEFORE PLACING PAVEMENT OR SIDEWALKS AND REPORT ANY DISCREPANCIES TO OWNER AND/OR ENGINEER. 7.CONTRACTOR SHALL REFER TO THE GEOTECHNICAL ENGINEERING REPORT FOR SITE CONSTRUCTION RECOMMENDATIONS. 8.CONTRACTOR SHALL STAKE SILT FENCE ALONG LIMITS OF DISTURBANCE LINE. THE SILT FENCE LINE TYPE IS OFFSET ON THE DRAWING FOR CLARITY. 9.THE CONTRACTOR SHALL USE EITHER RCP (CL. III) OR ADS HP STORM PIPE FOR THE STORM DRAINAGE SYSTEM. IF THE CONTRACTOR CHOOSES TO USE HP STORM PIPE, IT SHALL BE ADS N-12 WT STORM PIPE OR APPROVED EQUAL AND SHALL BE INSTALLED TO MANUFACTURER SPECIFICATIONS. IN ADDITION, THE CONTRACTOR SHALL BE SURE TO PROVIDE CONCRETE COLLARS AROUND EACH F.E.S. TO PREVENT FLOATATION IF HP STORM PIPE IS CHOSEN. IF HP STORM PIPE IS CHOSEN, ALL PIPING WITHIN THE PUBLIC RIGHT OF WAY MUST BE DUAL WALL HP-PIPE (GRAY) AS-BUILT STORMWATER NOTE [15A NCAC 02H.1044]: 1.)THE CONTRACTOR WILL EMPLOY A LAND SURVEYOR LICENSED IN THE STATE OF NORTH CAROLINA TO PROVIDE ACCURATE REPRODUCIBLE AS-BUILT DRAWINGS OF NEWLY INSTALLED COLLECTION SYSTEM, AND IMPERVIOUS AREA ON THE SITE TO THE ENGINEER & OWNER UPON COMPLETION OF CONSTRUCTION. UPON CERTIFICATION BY THE ENGINEER AND VERIFICATION FROM THE OWNER ANY DISCREPANCIES WILL BE INDICATED, THEN THESE PLANS SHALL BE RETURNED TO THE CONTRACTOR FOR CORRECTION PRIOR TO FINAL PAYMENT AND FINAL INSPECTION. SPECIAL USE PERMIT GENERAL NOTES: 1.THE PROPOSED DEVELOPMENT SHALL MEET OR EXCEED ALL NEW HANOVER COUNTY (NHC) ORDINANCE AND PERMIT REQUIREMENTS. 2.STORM WATER SHALL BE DESIGNED AND PERMITTED IN ACCORDANCE WITH ALL NEW HANOVER COUNTY AND STATE REQUIREMENTS. 3.PUBLIC WATER AND SEWER WILL BE EXTENDED BY THE DEVELOPER TO THE SITE. ALL DESIGN AND PERMITTING SHALL BE COORDINATED WITH CFPUA, NEW HANOVER COUNTY, AND STATE REGULATORS AS REQUIRED. 4.ALL LANDSCAPE & BUFFER MATERIALS AND INSTALLATION SHALL MEET OR EXCEED NHC UDO REQUIREMENTS. 5.ACCESS EASEMENTS WILL BE GRANTED FROM A PUBLIC ROAD TO EACH BMP FOR NHC ACCESS. LIMITS OF WETLANDS PROPOSED LIMITS OF DISTURBANCE (TYP.) PROPOSED SILT FENCE (TYP.) PROPOSED LIMITS OF DISTURBANCE (TYP.) PROPOSED SILT FENCE (TYP.) BRA Y S D R I V E PROPOSED INLET PROTECTION (TYP.) LEGEND: EXISTING CONTOUR PROPOSED CONTOUR EXISTING SPOT ELEVATION PROPOSED EDGE OF PAVEMENT PROPOSED SIDEWALK ELEVATION PROPOSED GRADE PROPOSED TOP OF WALL PROPOSED TOP OF CONCRETE 16 EG 25.05 EP 25.05 SW 25.05 LOD PG 25.05 TW 25.05 TC 17.15 16 NOTATION: CI =CURB INLET DI =DROP INLET CO =CLEANOUT DDI =DOUBLE DROP INLET MH =STORM DRAIN MANHOLE RD =ROOF DRAIN CLEANOUT FFE =FINISHED FLOOR ELEVATION BPE =BUILDING PAD ELEVATION DS =DOWNSPOUT LIMITS OF DISTURBANCE SILT FENCE TREE PROTECTION FENCING DRAINAGE FLOW PATH DRAINAGE INLET LABEL INLET PROTECTION EXISTING REGULATED TREE BY NHC CO-1 Planning Board - January 9, 2025 ITEM: 1 - 14 - 7 W E T W E T X X X X X X X X X X X X X X SIGN SS SMH RIM = 47.29 INV = 27.53 TOP OF INTERIOR PIPE = 38.63 SMH RIM = 47.33 INV = 26.08 SS SS SS SS SS SS SS SS SS SS SS SS SS SS RETAINING WALL CHAINLINK FENCE X CHAINLINK FENCE IRF IPF IPF IPF AXLEIPF IPF OH E OH E DU K E E N E R G Y P R O G R E S S , L L C EA S E M E N T DB 6 0 9 6 , P G 1 2 8 8 W W W W W W W W W W W W W W W W W FO FO FO FO FO FO FO WA T E R & S E W E R E A S E M E N T DB 5 2 2 2 , P G 1 8 4 7 XX X CA R O L I N A P O W E R & L I G H T C O M P A N Y DB 6 7 2 P G 1 7 7 50 ' F R O N T S E T B A C K W W W W W W W W W W W W W W W W S 36°02' 1 6 " E 116.92' N 4 2 ° 2 4 ' 0 1 " E 21 0 . 1 4 ' S 50°36'43" E 665.40' S 4 1 ° 3 4 ' 5 0 " W 21 0 . 0 0 ' N 50°36'43" W 668.41' R03600-006-082-000 ROBERT L. YUNASKA D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: I-1 LAND USE: VACANT INDUSTRIAL BFP R03600-005-008-000 GREGORY POOLE EQUIPMENT COMPANY D.B. 6645, PG. 1746 ZONING: B-2 LAND USE: COMMERCIAL R03600-005-005-000 SANDERS FAMILY STORAGE, LLC D.B. 6001, PG. 1677 ZONING: B-2 LAND USE: COMMERCIAL STORAGE 12P N 11O K 9OK PN 24 PN 24 MA 10 LO 21 MA 12 MA 16 MA 12MA 10 MA 17 PN 24LO 10 MA 10 LO 14 LO 16LO 60 LO 26 LO 14 MA 846 46 45 45 45 45 44 4 4 44 43 43 43 42 42 42 41 41 40 39 38 37 36 35 34 33 33 32 32 32 32 31 31 31 30 30 30 29 29 28 28 27 27 20 ' 10 0 ' S H O D S E T B A C K SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W 41 40 3539383736 35 34 33 33 424344 SU P - B - 2 Z O N I N G U T I L I T Y P L A N C-4.1 12 . 0 2 . 2 4 1" = 5 0 ' RP B RP B RP B VICINITY MAP NOT TO SCALE NORTH 140 SITE MAR K E T S T MA R S H RE A C H D R F O L L Y I S L A N D C T OA K S POR T E R S C R O S S I N G W A Y M A R S H DR P O R T E R S N E C K R D F U T C H C R E E K R D B A Y F I E L D D R 0 25 50 100 200 SCALE: 1"=50' GRAPHIC SCALEGRAPHIC SCALE FIRE HYDRANT ASSEMBLY, TYP. BA Y S H O R E T O W N H O M E S NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 24237.PE BA Y S H O R E T O W N H O M E S , L L C 20 1 N O R T H E L M S T R E E T , S U I T E 2 0 1 GR E E N S B O R O , N C 2 7 4 0 1 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL AP P L I C A N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 PR E L I M I N A R Y D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N SSMH-14 SSMH-13 SSMH-12 FIRE HYDRANT ASSEMBLY, TYP. FIRE HYDRANT ASSEMBLY, TYP. CONNECTION TO EXISTING WATER LINE. EXISTING 8" WATER LINE 8" C-900 (DR-18) PVC WATER MAIN 8" C-900 (DR-18) GRAVITY SEWER EXISTING SEWER LINE CAPE FEAR PUBLIC UTILTIY ATHORITY STANDARD NOTES: 1.ALL PROPOSED ADDITIONS TO THE CAPE FEAR PUBLIC UTILITY AUTHORITY (CFPUA) WATER DISTRIBUTION AND SANITARY SEWER COLLECTION SYSTEMS, AS SHOWN AND SPECIFIED HEREIN, SHALL BE DESIGNED AND CONSTRUCTED TO CONFORM TO STATE RULES AND THE CFPUA'S MINIMUM TECHNICAL STANDARDS ARE CONTAINED IN THE CURRENT DESIGN GUIDANCE MANUAL, MATERIAL SPECIFICATION MANUAL, TECHNICAL SPECIFICATIONS FOR CONSTRUCTION, AND STANDARD DRAWING DETAILS. 2.SEWER MANHOLE INSERTS REQUIRED AT ALL MANHOLES. STAINLESS STEEL MANHOLE INSERTS REQUIRED AT MANHOLES LOCATED IN TRAFFIC AREAS. 3.WATER AND SEWER SERVICES SHALL BE PERPENDICULAR TO MAIN AND TERMINATE 18" INSIDE THE RIGHT-OF-WAY LINE. SEWER SERVICES IN CUL-DE-SACS ARE REQUIRED TO BE PERPENDICULAR, OR MUST ORIGINATE IN END OF LINE MANHOLE AND TERMINATE 18" INSIDE RIGHT-OF-WAY LINE. 4.ALL SEWER SERVICES CONNECTING INTO DUCTILE IRON MAINS SHALL ALSO BE CONSTRUCTED OF DIP. 5.MINIMUM 10' UTILITIES EASEMENT PROVIDED ALONG THE FRONTAGE OF ALL LOTS AND AS SHOWN FOR NEW DEVELOPMENTS. 6.NO FLEXIBLE COUPLINGS SHALL BE USED. 7.ALL STAINLESS STEEL FASTENERS SHALL BE TYPE 316. 8.CLEANOUTS SHALL BE LOCATED A MINIMUM OF 6 FEET FROM ALL PROPERTY CORNERS. 9.WATER METER BOXES ARE TO BE A MINIMUM OF 5 FEET FROM THE PROPERTY CORNER. 10.UNUSED SERVICES SHALL BE ABANDONED, ABANDONED WATER SERVICES SHALL BE DISCONNECTED FROM MAIN. 11.A MINIMUM 10' OF MAIN LINE, 5' UPSTREAM AND 5' DOWNSTREAM SHALL BE REPLACED FOR NEW SEWER SERVICE CONNECTION TO EXISTING CLAY GRAVITY SEWER MAINS. 12.A MINIMUM OF 20' OF MAIN LINE, 10' UPSTREAM AND 10' DOWNSTREAM SHALL BE REPLACED FOR NEW CUT IN MANHOLES ON EXISTING CLAY GRAVITY SEWER MAINS. 13.PROVIDED A MINIMUM DISTANCE OF SIX(6) INCHES BETWEEN EDGES OF CORE HOLES. CORING THE MANHOLE CONE IS NOT PERMITTED. 14.WATER MAIN AND FORCE MAIN PIPE INSTALLED BY OPEN CUT SHALL BE BURIED AT A MINIMUM OF THREE (3) FEET AND A MAXIMUM OF FIVE (5) FEET BELOW FINISHED GRADE. DEPTHS GREATER THAN FIVE (5) FEET MUST BE APPROVED BY CFPUA. 15.ALL MANHOLE MAIN LINE AND SERVICE PIPING TO BE INSTALLED AT A MINIMUM OF CROWN TO CROWN OF THE LARGEST DIAMETER PIPE. FIRE & LIFE SAFETY NOTES: 1.NEW HYDRANTS MUST BE AVAILABLE FOR USE PRIOR TO CONSTRUCTION OF THE BUILDINGS WITHIN ANY DEVELOPMENT. 2.HYDRANTS MUST BE LOCATED WITHIN 8' OF THE CURB. 3.CONTRACTOR SHALL MAINTAIN AN ALL WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES DURING CONSTRUCTION. 4.A MINIMUM OF 4' SHALL SEPARATE UNDERGROUND FIRE LINES OR PRIVATE WATER MAINS FROM OTHER UNDERGROUND UTILITIES. 5.LANDSCAPING OR PARKING CANNOT BLOCK OR IMPEDE THE FDC OR FIRE HYDRANTS OR ACCESS TO THESE APPARATUSES. A 3-FOOT (3') CLEAR SPACE SHALL BE MAINTAINED AROUND THE CIRCUMFERENCE OF HYDRANTS AND FDC. 6.HYDRANTS SHOULD BE 18 INCHES FROM THE CENTERLINE OF THE STEAMER CONNECTION TO FINISH GRADE, THIS INCLUDES LANDSCAPING. STEAMER CONNECTIONS SHALL FACE THE STREET. 7.FIRE HYDRANTS SHOULD NOT BE BLOCKED BY PARKING SPACES OR UTILITIES. 8.THE GATE AT THE ACCESS TO BRAYS DRIVE IS FOR EMERGENCY ACCESS ONLY AND SHALL BE SIREN ACTIVATED OR A KNOW BOX PROVIDED. UTILITY INFORMATION CONTRACTOR SHALL INSTALL WATER AND SEWER SERVICES IN ACCORDANCE WITH CFPUA STANDARD DETAILS AND SPECIFICATIONS. SANITARY SEWER THIS PROJECT IS PROPOSING 8" SANITARY SEWER MAINS THROUGHOUT DEVELOPMENT WITH INDIVIDUAL SERVICES TO EACH UNIT. THE PROPOSED COLLECTION SYSTEM WILL CONNECT TO AN EXISTING CFPUA GRAVITY SEWER SYSTEM LOCATED ON-SITE. ALL SANITARY SEWER ALLOCATION PROVIDED BY CFPUA. CONTRACTOR TO COORDINATE SANITARY TIE-IN TO EXISTING FACILITIES WITH CFPUA. CFPUA INSPECTOR TO BE ON-SITE DURING TAPPING OF EX. SEWER FACILITIES. SANITARY IN-LINE PLUGS ARE REQUIRED AT ALL CONNECTION POINTS TO EX. SEWER FACILITIES AND MUST REMAIN IN PLACE UNTIL CONSTRUCTION IS COMPLETE AND CFPUA HAS COMPLETED ITS INSPECTION. WATER THIS PROJECT IS PROPOSING 6-INCH AND 8-INCH PUBLIC WATER MAINS LOCATED THROUGHOUT THE DEVELOPMENT WITH CONNECTIONS TO THE EXISTING WATER SYSTEM IN THREE (3) DIFFERENT LOCATIONS. INDIVIDUAL SERVICES WILL BE PROVIDED FOR EACH UNIT. ALL DOMESTIC WATER ALLOCATION PROVIDED BY CFPUA. CONTRACTOR TO COORDINATE WATER TIE-IN TO EXISTING FACILITIES WITH CFPUA. CFPUA INSPECTORS ARE REQUIRED TO BE ON-SITE DURING TAPPING OF THE EX. UTILITIES. UTILITY NOTES: (NCAC 15A.02T.0305 / T15A.18C.0906) 1.PER RULE .0904, WATER MAINS MUST BE BURIED TO A DEPTH BELOW THE FROST LINE OR TO A DEPTH SUFICIENT TO PROVIDE A MINIMUM OF 30 INCHES, WHICHEVER IS GREATER. 2.LATERAL SEPARATION OF SEWERS AND WATER MAINS. WATER MAINS SHALL BE LAID AT LEAST 10 FEET LATERALLY FROM EXISTING OR PROPOSED SEWERS, UNLESS LOCAL CONDITIONS OR BARRIERS PREVENT A 10-FOOT LATERAL SEPARATION, IN WHICH CASE: (1) THE THE WATER MAIN IS SHALL BE LAID IN A SEPARATE TRENCH, WITH THE ELEVATION OF THE BOTTOM OF THE WATER MAIN AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER; OR (2) THE WATER MAIN IS SHALL BE LAID IN THE SAME TRENCH AS THE SEWER, WITH THE WATER MAIN LOCATED AT ONE SIDE ON A BENCH OF UNDISTURBED EARTH, AND WITH THE ELEVATION OF THE BOTTOM OF THE WATER MAIN AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER. 3.A WATER MAIN THAT CROSSES A SEWER SHALL BE LAID A MINIMUM VERTICAL DISTANCE OF 18 INCHES FROM THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF THE SEWER, EITHER ABOVE OR BELOW THE SEWER BUT, IF PRACTICABLE, THE WATER MAIN SHALL BE LOCATED ABOVE THE SEWER. ONE FULL LENGTH OF WATER PIPE SHALL BE LOCATED SO THAT BOTH JOINTS WILL BE AS FAR FROM THE SEWER AS POSSIBLE. 4.TO ALLOW FOR CONSTRUCTION AND REPAIR, A MINIMUM DISTANCE OF 12 INCHES SHALL BE MAINTAINED BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF OTHER UTILITIES. 5.WATER MAINS AND RECLAIMED WATER DISTRIBUTION LINES. WATER LINES SHALL BE LOCATED AT LEAST 10 FEET HORIZONTALLY FROM OR AT LEAST 18 INCHES ABOVE WATER PIPES CARRYING TREATED AND DISINFECTED WASTEWATER IN RECLAIMED WATER DISTRIBUTION LINES. CROSSINGS SHALL BE MADE IN ACCORDANCE WITH NUMBER 2 ABOVE. FIRE LINE NOTE: SITE CONTRACTOR SHALL COORDINATE WITH FIRE SUPPRESSION DESIGN BUILD TO CONFIRM FIRE SERVICE SIZE PRIOR TO ORDERING ANY MATERIAL OR INSTALLATION. SITE CONTRACTOR SHALL INSTALL FIRE LINE INSIDE RISER ROOM AND TERMINATE 12" AFF. EX. SERVICES NOTE: ANY EXISTING SERVICES NOT USED WILL NEED TO BE PROPERLY ABANDONED AT THE MAIN IN ACCORDANCE WITH CFPUA STANDARDS AND SPECIFICATIONS FIRE HYDRANT ASSEMBLY, TYP. PROPOSED BUILDING #1 PROPOSED BUILDING #2 EXISTING, REGULATE TREE PER NHC, TYP. Planning Board - January 9, 2025 ITEM: 1 - 14 - 8 RIP RIP 22O K W E T W E T W E T W E T WETWETWET WETWET WE T W E T W E T WETWET W E T WET WET W E T WET WE T W E T WE T WE T IPF IPF IRF IPF PKF IPF IPF IPFIPF CMF IPF IRF IRF INV: 23.14 12" CPP INV: DAMAGED N 0 5 ° 1 2 ' 0 1 " E 5 3 8 . 0 4 ' S 36°02' 1 6 " E 116.92' N 3 9 ° 3 9 ' 4 1 " E 33 0 . 6 1 ' S 50°28'07" E 115.22' N 3 9 ° 3 9 ' 0 6 " E 16 0 . 3 1 ' S 50°19'17" E 150.03' L1 L2 S 48°16'45" E 506.30'L3 S 47°46'24" E 121.53'S 48°24'53" E 581.39' S 4 1 ° 2 5 ' 4 8 " W 31 0 . 4 8 ' N 48°34'06" W 121.43' S 4 2 ° 5 5 ' 4 8 " W 75 0 . 7 0 ' L4 L5L6 L7L8L9N 47°17'46" W 107.98' L10L11L12 L13 L1 4 L1 5 L1 6 L17 L 1 8 L 1 9 L20 L 2 1 L 2 2 L 2 3 N 64°11'4 9 " W 421.13' S 4 1 ° 3 4 ' 5 0 " W 21 0 . 0 0 ' LOT 142 R03600-006-012-000 RICHARD MOBURG ELIZABETH MOBURG D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 143 R03600-006-013-000 NORA E. BENEVENTI REVOCABLE TRUST D.B. 5020, PG. 2264 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 144 R03600-006-014-000 DAVID M. RENQUIST MARY E. RENQUIST D.B. 5020, PG. 2264 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 147 R03600-006-017-000 PRUDENTIAL RELOCATION INC. D.B. 5238, PG. 722 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 148 R03600-006-018-000 BRADLEY J. ERBES TAMI L. ERBES D.B. 5238, PG. 722 M.B. 43, PG. 372 ZONING: R-15 LAND USE: RESIDENTIAL LOT 149 R03600-006-024-000 ERNEST W. OLDS DAWN M. OLDS D.B. 6056, PG. 182 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL LOT 150 R03600-006-025-000 RICHARD MIMMS SUPATRA MIMMS D.B. 6221, PG. 2760 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL LOT 151 R03600-006-026-000 MADISON M. NEWSOME BUNJONG P. NEWSOME D.B. 4655, PG. 304 M.B. 44, PG. 307 ZONING: R-15 LAND USE: RESIDENTIAL R03600-006-082-000 ROBERT L. YUNASKA D.B. 4626, PG. 912 M.B. 43, PG. 372 ZONING: I-1 LAND USE: VACANT INDUSTRIAL R0 3 7 0 0 - 0 0 4 - 2 9 3 - 0 0 0 PO R T E R ' S P O I N T E HO M E O W N E R S AS S O C I A T I O N , I N C D. B . 5 7 9 0 , P G . 3 5 M. B . 5 5 , P G . 3 4 0 18' PRIVATE ALLEY R03700-004-293-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL COMMUNITY OPEN SPACE R03700-004-294-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL AMENITY R03705-006-007-000 KATHRYN WOLFE & LARRY STEVEN MORGAN D.B. 6025, PG. 1493 M.B. 46, PG. 25 ZONING: R-15 LAND USE: RESIDENTIAL R03705-006-012-000 JOANN M. WAINIO D.B. 5694, PG. 1838 M.B. 46, PG. 25 ZONING: R-15 LAND USE: RESIDENTIAL L O T 4 8 R 0 3 7 0 0 - 0 0 4 - 2 7 9 - 0 0 0 J O R Y A N D E R S O N & A B B Y R I C H O M N D D . B . 6 6 7 5 , P G . 1 3 2 7 M. B . 5 5 , P G . 3 4 0 Z O N I N G : R - 1 5 L A N D U S E : R E S I D E N T I A L 36 . 2 ' 24.2' R0 3 7 0 0 - 0 0 4 - 1 9 1 - 0 0 0 PO R T E R S C R O S S I N G HO A I N C D. B . 5 1 9 0 , P G . 1 2 0 4 M. B . 5 1 , P G . 1 5 4 ZO N I N G : R - 1 5 LA N D U S E : RE S I D E N T I A L A M E N I T Y R03700-004-301-000 DEREK REEVES D.B. 5625, PG. 1573 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-300-000 STEVE LINDNER D.B. 6031, PG. 2140 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-299-000 EDWARD SOUTHERLAND D.B. 5571, PG. 1535 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-298-000 ANNA ROVETTO D.B. 6636, PG. 1714 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-297-000 ROCHELLE KREINER D.B. 6406, PG. 1314 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-296-000 CAMERON DANIEL D.B. 6290, PG. 242 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-295-000 RICHARD WILSON D.B. 5545, PG. 2050 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL R03700-004-011-000 PORTERS CROSSING HOA INC D.B. 6102, PG. 2894 M.B. 51, PG. 154 ZONING: R-15 LAND USE: RESIDENTIAL AMENITY 15PN 17PN 15PN 18PN 17P N 15G M 20PN 24P N 4EL 24O K 7MG10O K 8OK 9OK 14P N 13P N 12PN 17PN 21PN 18O K 10O K 21P N 20P N8OK 6MG 14O K10O K 10O K 18PN 12O K 11O K 16PN 15P N 8OK17P N16P N 23P N 20PN 18PN 15PN 16P N 4CE 15P N 13P N 8OK 12P N 13O K 14P N 8OK 12P N 10O K 12OK 18O K 24PN 14PN 9OK 18OK 27P N 14PN 18P N 17PN 14PN 10G M 13P N 14O K 19P N 12PN 14PN 15PN 12PN 8OK 17O K 17O K12P N 15P N 12O K 16G M 17O K 4CM 21P N 10G M 22PN 22P N 13O K 21PN 12O K 15P N 18P N 12P N 12P N 13PN 19P N 12P N 13PN 4MG 12PN 8OK8MA 15O K 10OK 8OK 17O K 18OK 27O K 17O K 18O K 27PN 15OK 18O K17O K 28O K 19O K 27O K 19O K 35O K 20P N 24P N 9OK 6DW 5DW 10OK 14O K 20O K 23O K 24O K 35O K 24P N 19PN 22PN 29P N 8PR 10PA 16P A 23P N 25P N 18PN 18PN 36P N 14PN 17P N 15P N 16P N 14P N 17P N 20PN 22P N 24P N 26G M 17P N 15PN 12PN 13PN 13PN16PN 21P N 13PN 23P N 17P N 13P N 14PN 20PN 13P N 15GM15GM 15P N 18PN 14P N 12PN 20PN 5SY 12PN 11O K 12P N 15PN 13P N 8GM 11OK 10O K 9OK 13OK 13P N 14PN 18P N 14P N 8MG 18PN 15P N 20PN 9OK 13G M 8OK 8GM 13G M 11O K 12P N 15PN 10OK 18P N 15P N 12PN 18PN 10O K 18O K 10O K 9OK 6SY 4MG 15PN 8OK 13G M 8OK 20P N 15PN 10O K 30P N 16O K 10O K 9PO 26O K 20O K 15O K 14O K 30O K 10O K 8GM 7MG 13O K 8PO 11G M 9HI 8OK 13O K 24P N 18PO 10H I 11HI 8OK 26PN 18O K 18P N 11GM 19P N 13PN 19P N 12M A 19PN 20P N20PN23PO 21PN 20PN 20PN 10SY 13P N 5,4C M ( C L U S T E R ) 21P N 13P N 13O K11G M 23PN 14PA 8CH 6MM 15OK 27PN 17O K 36P N23P N 12PN 13O K 12O K12O K 29PO 13O K 12PN 12PN 10G M 14PN 19PN 15O K 10G M 18PN 21P N 20PN12G M 5MG 9GM 5MM 18PN 8GM 10O K 9OK 8MA 8GM 8GM 10G M 14G M 8MM 8GM 10G M 10GM 11M A 14P N 9OK 12P N 6PO 20PO 20P O 8OK 15PN 8MA 12M A 9MM 17G M 10O K 15PO 20O K 12PN 24O K 6CT 6CT 8CT 6CT 10O K18PN 12OK SS SS S S S S S S S S SS SS SS SS SS SS SS SS SS SS SS SS S S S S S S SS SS SS SS SS SS SS SS S S S S SS SS SS TV SS SMH RIM = 30.20 INV = 15.14 SMH RIM =29.38 INV = 14.71 SMH RIM =30.67 INV = 12.96 SMH RIM =17.54 INV =11.05 SMH RIM = 17.61 UNABLE TO OPEN SMH RIM =17.62 INV = 10.45 SMH RIM =16.43 INV = 10.02 SMH RIM =16.62 INV =9.21 SMH RIM =16.94 INV =8.46 SMH RIM =18.45 INV = 11.25 SW E E T W A T E R B R A N C H R03700-004-293-000 PORTER'S POINTE HOMEOWNERS ASSOCIATION, INC D.B. 5790, PG. 35 M.B. 55, PG. 340 ZONING: R-15 LAND USE: RESIDENTIAL COMMUNITY OPEN SPACE 24 23 23 2322 22 22 22 21 21 21 21 21 21 20 20 20 20 20 20 20 20 19 19 19 19 19 19 19 19 19 18 18 18 18 18 18 18 18 18 18 18 17 17 17 17 17 17 17 17 17 17 17 17 17 16 16 16 16 16 16 16 16 16 16 16 16 16 16 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 14 14 14 14 14 14 14 14 14 14 13 13 13 13 13 43 42 41 40 40 39 39 38 38 37 37 36 36 35 35 34 34 34 33 33 33 32 32 32 32 31 31 31 31 31 31 31 30 30 30 30 30 30 30 30 29 29 29 29 29 29 29 29 29 29 29 29 2929 29 28 28 28 28 28 28 28 28 28 27 27 27 27 27 27 27 27 27 27 2 7 27 27 27 27 27 27 26 26 26 26 26 26 26 26 26 2 6 26 2 6 26 26 26 26 26 26 26 25 25 25 25 25 25 25 25 25 25 25 25 25 25 24 2 4 24 24 24 2 4 2424 24 24 23 23 23 23 23 23 2323 23 23 22 22 22 22 22 22 2222 22 21 2 1 21 19 21 21 21 21 21 2 0 20 20 20 20 20 20 20 19 19 19 19 18 18 18 17 17 24 21 20 19 18 22 21 222324 26 24 25 26 23 22 21 20 21 22 23 24 25 20 18 18 19 19 26 25 24 23 22 21 24 25 26 23 22 21 20 18 17 16 19 15 14 13 12 11 24 25 26 23 22 21 20 12 13 14 11 1516171819 20 1 8 17 1 6 19 1 5 14 1 3 1 2 11 212223242625 26 25 242322 21 19181716 1514 20 24 25 26 23 22 21 20 12 13 14 11 1516171819 EXISTING POND NHC EASEMENT WETWETWET WETWET WE T W E T W E T WETWET W E T WET WET W E T WET WE T W E T WE T WE T 20 ' 40' DRAINAGE & PUBLIC UTILITIES EASEMENT W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W SSSSSSSSSSSSSSSSSS WWWWWWWWWWWW W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSS W W W WWWWWWWWWWWWWW WWWWWWWWWWWW SS 20 22 23 24 25 21 26 27 27 28 191817161514 13 12 112727262524232221 20 19 18 17 16 15 14 13 27 26 25 24 2 4 23 PROPOSED STORMWATER POND PROPOSED STORMWATER POND 21 20 21 20 19 40 ' D R A I N A G E & P U B L I C U T I L I T I E S E A S E M E N T X X X X XX 50 ' N H C C O D B U F F E R O F F P O N D E D G E SU P - R - 1 5 Z O N I N G U T I L I T Y P L A N C-4.2 12 . 0 2 . 2 4 1" = 6 0 ' RP B RP B RP B VICINITY MAP NOT TO SCALE NORTH 140 SITE MAR K E T S T MA R S H RE A C H D R F O L L Y I S L A N D C T OA K S POR T E R S C R O S S I N G W A Y M A R S H DR P O R T E R S N E C K R D F U T C H C R E E K R D B A Y F I E L D D R 0 30 60 120 240 SCALE: 1"=60' GRAPHIC SCALEGRAPHIC SCALE BA Y S H O R E T O W N H O M E S NE W H A N O V E R C O U N T Y NO R T H C A R O L I N A 24237.PE BA Y S H O R E T O W N H O M E S , L L C 20 1 N O R T H E L M S T R E E T , S U I T E 2 0 1 GR E E N S B O R O , N C 2 7 4 0 1 DA T E : SC A L E : DE S I G N E D : DR A W N : CH E C K E D : PEI JOB#: CO N C E P T U A L L A Y O U T : PR E L I M I N A R Y L A Y O U T : FI N A L D E S I G N : RE L E A S E D F O R C O N S T : PR O J E C T S T A T U S RE V I S I O N S : DR A W I N G I N F O R M A T I O N SEAL AP P L I C A N T I N F O R M A T I O N : 12 2 C i n e m a D r i v e Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 (9 1 0 ) 7 9 1 - 6 7 0 7 ( O ) ( 9 1 0 ) 7 9 1 - 6 7 6 0 ( F ) NC L i c e n s e # : C - 2 8 4 6 PR E L I M I N A R Y D E S I G N - N O T R E L E A S E D F O R C O N S T R U C T I O N CAPE FEAR PUBLIC UTILTIY ATHORITY STANDARD NOTES: 1.ALL PROPOSED ADDITIONS TO THE CAPE FEAR PUBLIC UTILITY AUTHORITY (CFPUA) WATER DISTRIBUTION AND SANITARY SEWER COLLECTION SYSTEMS, AS SHOWN AND SPECIFIED HEREIN, SHALL BE DESIGNED AND CONSTRUCTED TO CONFORM TO STATE RULES AND THE CFPUA'S MINIMUM TECHNICAL STANDARDS ARE CONTAINED IN THE CURRENT DESIGN GUIDANCE MANUAL, MATERIAL SPECIFICATION MANUAL, TECHNICAL SPECIFICATIONS FOR CONSTRUCTION, AND STANDARD DRAWING DETAILS. 2.SEWER MANHOLE INSERTS REQUIRED AT ALL MANHOLES. STAINLESS STEEL MANHOLE INSERTS REQUIRED AT MANHOLES LOCATED IN TRAFFIC AREAS. 3.WATER AND SEWER SERVICES SHALL BE PERPENDICULAR TO MAIN AND TERMINATE 18" INSIDE THE RIGHT-OF-WAY LINE. SEWER SERVICES IN CUL-DE-SACS ARE REQUIRED TO BE PERPENDICULAR, OR MUST ORIGINATE IN END OF LINE MANHOLE AND TERMINATE 18" INSIDE RIGHT-OF-WAY LINE. 4.ALL SEWER SERVICES CONNECTING INTO DUCTILE IRON MAINS SHALL ALSO BE CONSTRUCTED OF DIP. 5.MINIMUM 10' UTILITIES EASEMENT PROVIDED ALONG THE FRONTAGE OF ALL LOTS AND AS SHOWN FOR NEW DEVELOPMENTS. 6.NO FLEXIBLE COUPLINGS SHALL BE USED. 7.ALL STAINLESS STEEL FASTENERS SHALL BE TYPE 316. 8.CLEANOUTS SHALL BE LOCATED A MINIMUM OF 6 FEET FROM ALL PROPERTY CORNERS. 9.WATER METER BOXES ARE TO BE A MINIMUM OF 5 FEET FROM THE PROPERTY CORNER. 10.UNUSED SERVICES SHALL BE ABANDONED, ABANDONED WATER SERVICES SHALL BE DISCONNECTED FROM MAIN. 11.A MINIMUM 10' OF MAIN LINE, 5' UPSTREAM AND 5' DOWNSTREAM SHALL BE REPLACED FOR NEW SEWER SERVICE CONNECTION TO EXISTING CLAY GRAVITY SEWER MAINS. 12.A MINIMUM OF 20' OF MAIN LINE, 10' UPSTREAM AND 10' DOWNSTREAM SHALL BE REPLACED FOR NEW CUT IN MANHOLES ON EXISTING CLAY GRAVITY SEWER MAINS. 13.PROVIDED A MINIMUM DISTANCE OF SIX(6) INCHES BETWEEN EDGES OF CORE HOLES. CORING THE MANHOLE CONE IS NOT PERMITTED. 14.WATER MAIN AND FORCE MAIN PIPE INSTALLED BY OPEN CUT SHALL BE BURIED AT A MINIMUM OF THREE (3) FEET AND A MAXIMUM OF FIVE (5) FEET BELOW FINISHED GRADE. DEPTHS GREATER THAN FIVE (5) FEET MUST BE APPROVED BY CFPUA. 15.ALL MANHOLE MAIN LINE AND SERVICE PIPING TO BE INSTALLED AT A MINIMUM OF CROWN TO CROWN OF THE LARGEST DIAMETER PIPE. FIRE HYDRANT ASSEMBLY, TYP. 8" C-900 (DR-18) PVC WATER MAIN 8" C-900 (DR-18) GRAVITY SEWER FIRE HYDRANT ASSEMBLY, TYP. FIRE HYDRANT ASSEMBLY, TYP.FIRE HYDRANT ASSEMBLY, TYP. FIRE HYDRANT ASSEMBLY, TYP. FIRE HYDRANT ASSEMBLY, TYP. FIRE HYDRANT ASSEMBLY, TYP. FIRE HYDRANT ASSEMBLY, TYP. FIRE HYDRANT ASSEMBLY, TYP. FIRE HYDRANT ASSEMBLY, TYP.FIRE HYDRANT ASSEMBLY, TYP. FIRE HYDRANT ASSEMBLY, TYP. FIRE HYDRANT ASSEMBLY, TYP. SSMH-X1 SSMH-X2 SSMH-01 SSMH-02 SSMH-03SSMH-04SSMH-06 SSMH-05 SSMH-07SSMH-08 SSMH-09 SSMH-10SSMH-11 SSMH-12 SSMH-13 SSMH-14SSMH-15 SSMH-17 SSMH-16 SSMH-18 SSMH-19 8" C-900 (DR-18) PVC WATER MAIN 8" C-900 (DR-18) GRAVITY SEWER FIRE & LIFE SAFETY NOTES: 1.NEW HYDRANTS MUST BE AVAILABLE FOR USE PRIOR TO CONSTRUCTION OF THE BUILDINGS WITHIN ANY DEVELOPMENT. 2.HYDRANTS MUST BE LOCATED WITHIN 8' OF THE CURB. 3.CONTRACTOR SHALL MAINTAIN AN ALL WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES DURING CONSTRUCTION. 4.A MINIMUM OF 4' SHALL SEPARATE UNDERGROUND FIRE LINES OR PRIVATE WATER MAINS FROM OTHER UNDERGROUND UTILITIES. 5.LANDSCAPING OR PARKING CANNOT BLOCK OR IMPEDE THE FDC OR FIRE HYDRANTS OR ACCESS TO THESE APPARATUSES. A 3-FOOT (3') CLEAR SPACE SHALL BE MAINTAINED AROUND THE CIRCUMFERENCE OF HYDRANTS AND FDC. 6.HYDRANTS SHOULD BE 18 INCHES FROM THE CENTERLINE OF THE STEAMER CONNECTION TO FINISH GRADE, THIS INCLUDES LANDSCAPING. STEAMER CONNECTIONS SHALL FACE THE STREET. 7.FIRE HYDRANTS SHOULD NOT BE BLOCKED BY PARKING SPACES OR UTILITIES. 8.THE GATE AT THE ACCESS TO BRAYS DRIVE IS FOR EMERGENCY ACCESS ONLY AND SHALL BE SIREN ACTIVATED OR A KNOW BOX PROVIDED. UTILITY INFORMATION CONTRACTOR SHALL INSTALL WATER AND SEWER SERVICES IN ACCORDANCE WITH CFPUA STANDARD DETAILS AND SPECIFICATIONS. SANITARY SEWER THIS PROJECT IS PROPOSING 8" SANITARY SEWER MAINS THROUGHOUT DEVELOPMENT WITH INDIVIDUAL SERVICES TO EACH UNIT. THE PROPOSED COLLECTION SYSTEM WILL CONNECT TO AN EXISTING CFPUA GRAVITY SEWER SYSTEM LOCATED ON-SITE. ALL SANITARY SEWER ALLOCATION PROVIDED BY CFPUA. CONTRACTOR TO COORDINATE SANITARY TIE-IN TO EXISTING FACILITIES WITH CFPUA. CFPUA INSPECTOR TO BE ON-SITE DURING TAPPING OF EX. SEWER FACILITIES. SANITARY IN-LINE PLUGS ARE REQUIRED AT ALL CONNECTION POINTS TO EX. SEWER FACILITIES AND MUST REMAIN IN PLACE UNTIL CONSTRUCTION IS COMPLETE AND CFPUA HAS COMPLETED ITS INSPECTION. WATER THIS PROJECT IS PROPOSING 6-INCH AND 8-INCH PUBLIC WATER MAINS LOCATED THROUGHOUT THE DEVELOPMENT WITH CONNECTIONS TO THE EXISTING WATER SYSTEM IN THREE (3) DIFFERENT LOCATIONS. INDIVIDUAL SERVICES WILL BE PROVIDED FOR EACH UNIT. ALL DOMESTIC WATER ALLOCATION PROVIDED BY CFPUA. CONTRACTOR TO COORDINATE WATER TIE-IN TO EXISTING FACILITIES WITH CFPUA. CFPUA INSPECTORS ARE REQUIRED TO BE ON-SITE DURING TAPPING OF THE EX. UTILITIES. UTILITY NOTES: (NCAC 15A.02T.0305 / T15A.18C.0906) 1.PER RULE .0904, WATER MAINS MUST BE BURIED TO A DEPTH BELOW THE FROST LINE OR TO A DEPTH SUFICIENT TO PROVIDE A MINIMUM OF 30 INCHES, WHICHEVER IS GREATER. 2.LATERAL SEPARATION OF SEWERS AND WATER MAINS. WATER MAINS SHALL BE LAID AT LEAST 10 FEET LATERALLY FROM EXISTING OR PROPOSED SEWERS, UNLESS LOCAL CONDITIONS OR BARRIERS PREVENT A 10-FOOT LATERAL SEPARATION, IN WHICH CASE: (1) THE THE WATER MAIN IS SHALL BE LAID IN A SEPARATE TRENCH, WITH THE ELEVATION OF THE BOTTOM OF THE WATER MAIN AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER; OR (2) THE WATER MAIN IS SHALL BE LAID IN THE SAME TRENCH AS THE SEWER, WITH THE WATER MAIN LOCATED AT ONE SIDE ON A BENCH OF UNDISTURBED EARTH, AND WITH THE ELEVATION OF THE BOTTOM OF THE WATER MAIN AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER. 3.A WATER MAIN THAT CROSSES A SEWER SHALL BE LAID A MINIMUM VERTICAL DISTANCE OF 18 INCHES FROM THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF THE SEWER, EITHER ABOVE OR BELOW THE SEWER BUT, IF PRACTICABLE, THE WATER MAIN SHALL BE LOCATED ABOVE THE SEWER. ONE FULL LENGTH OF WATER PIPE SHALL BE LOCATED SO THAT BOTH JOINTS WILL BE AS FAR FROM THE SEWER AS POSSIBLE. 4.TO ALLOW FOR CONSTRUCTION AND REPAIR, A MINIMUM DISTANCE OF 12 INCHES SHALL BE MAINTAINED BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF OTHER UTILITIES. 5.WATER MAINS AND RECLAIMED WATER DISTRIBUTION LINES. WATER LINES SHALL BE LOCATED AT LEAST 10 FEET HORIZONTALLY FROM OR AT LEAST 18 INCHES ABOVE WATER PIPES CARRYING TREATED AND DISINFECTED WASTEWATER IN RECLAIMED WATER DISTRIBUTION LINES. CROSSINGS SHALL BE MADE IN ACCORDANCE WITH NUMBER 2 ABOVE. FIRE LINE NOTE: SITE CONTRACTOR SHALL COORDINATE WITH FIRE SUPPRESSION DESIGN BUILD TO CONFIRM FIRE SERVICE SIZE PRIOR TO ORDERING ANY MATERIAL OR INSTALLATION. SITE CONTRACTOR SHALL INSTALL FIRE LINE INSIDE RISER ROOM AND TERMINATE 12" AFF. EX. SERVICES NOTE: ANY EXISTING SERVICES NOT USED WILL NEED TO BE PROPERLY ABANDONED AT THE MAIN IN ACCORDANCE WITH CFPUA STANDARDS AND SPECIFICATIONS Planning Board - January 9, 2025 ITEM: 1 - 14 - 9