Loading...
HomeMy WebLinkAboutTechnical Memorandum for Comet Apartments 5/19/2021 210239: Scotts Hill Apartments – Trip Generation 1 Scotts Hill Apartments Trip Generation Memorandum DAVENPORT Project Number 210239 Prepared for Comet Development May 19, 2021 This memorandum provides trip generation information for the proposed Scotts Hill Apartments site, to be located on east side of US 17 in New Hanover County, just south of the Pender County line. The subject site is part of the Scotts Hill Medical Park site, for which a TIA was previously completed by DAVENPORT on June 4, 2019. The purpose of this memorandum is to show that the trip generation of the updated land uses do not increase the trip generation of the site, and therefore the previously identified roadway improvements associated with this site should remain adequate. Figure 1 shows a sketch plan of the subject parcel, as well as the other three (3) parcels of Scotts Hill Medical Park. The site is accessible by two (2) locations on US 17: a future access located approximately 550 feet north of Creekwood Road, and by Scotts Hill Medical Drive which connects to the site via Senca Drive. There is currently a bollarded southbound left turn lane on US 17 to the future access, which will need removal of the bollards once the driveway is constructed. The subject parcel is proposed to consist of 256 apartment units, and two (2) outparcels. The land use of these outparcels is not yet known. For trip generation purposes, these were analyzed as 15,000 square feet of retail space. Table 1 below provides a comparison of the previously analyzed land uses and the updated land uses, based on information from the developer. Note that one parcel has been built to date, which is the Wilmington Eye medical office building (“Lot 2” in Figure 1), with a floor area of approximately 23,400 square feet. Table 1 - Land Use Comparison Land Use Variable Previous (June 2019 TIA) Updated Difference (Updated Minus Previous) General Office 1000 GFA 132.0 45.2 -87 Medical Office 1000 GFA 18.0 23.4 +5 Shopping Center (Retail) 1000 GLA 32.0 15 -17 Pharmacy (Drive-Through Window) 1000 GLA 9.0 9.0 0 Apartments Dwelling Units 256 +256 Table 2 shows the previous trip generation from the June 2018 TIA. This establishes a trip generation “budget” against which the new land uses could be compared. Table 3 shows the trip generation results for the updated land uses, as well as the net difference between the new and old trip generations. Trip generation was computed based on rates and equations from the ITE Trip Generation Manual 10th Edition, in accordance with NCDOT Congestion Management standards. 5/19/2021 210239: Scotts Hill Apartments – Trip Generation 2 Table 2 - Previous Trip Generation (June 2019 TIA) Scott's Hill Medical Park (Full Build) Average Weekday Driveway Volumes 24 Hour Two-Way AM Peak Hour PM Peak Hour Land Use ITE Land Code Size Method - Type Volume Enter Exit Enter Exit General Office 710 132.0 1000 GFA Generator/ Equation 1,389 187 25 38 173 Medical Office 720 18.0 1000 GFA Adjacent/ Rate 626 39 11 17 45 Shopping Center (Retail) 820 32.0 1000 GLA Adjacent/ Equation 2,770 104 64 112 122 Pharmacy (Drive-Through Window) 881 9.0 1000 GLA Adjacent/ Rate 982 18 17 46 47 Total Unadjusted Trips 5,767 348 117 213 387 Office -9 -10 -4 -11 Retail -10 -9 -9 -3 Total Internal Trips Reduction - -19 -19 -13 -14 Shopping Center (0% AM, 34% PM) 0 0 -38 -38 Pharmacy (0% AM, 49% PM) 0 0 -22 -22 Total Pass-By Peak Reduction - 0 0 -60 -60 Total Adjusted (Primary) Trips - 329 98 140 313 Table 3 - Updated Trip Generation Scotts Hill Apartments Average Weekday Driveway Volumes 24 Hour Two-Way AM Peak Hour PM Peak Hour Land Use ITE Land Code Size Method - Type Volume Enter Exit Enter Exit Apartments 220 256 Dwelling Units Adjacent/ Equation 1,895 27 90 86 50 Pharmacy (Drive-Through Window) 881 9.0 1000 GFA Adjacent/ Rate 982 19 16 47 46 Medical Office (Wilmington Eye) 720 23.4 1000 GFA Adjacent/ Rate 814 51 14 23 58 General Office 710 45.2 1000 GFA Generator/ Equation 491 73 10 21 94 Outparcels: Retail 820 15 1000 GLA Adjacent/ Equation 1,655 99 60 64 69 Total Unadjusted Trips 5,837 269 190 241 317 Difference (New Minus Previous Trips) +70 -79 +73 +28 -70 Total Internal Trips Reduction (6% AM, 19% PM) - -16 -11 -46 -60 LUC 820 General Retail (0%AM, 34% PM) 0 0 -18 -18 LUC 881 Pharmacy with Drive-Thru Window (0%AM, 49% PM) 0 0 -19 -19 Total Pass-By Peak Reduction - 0 0 -37 -37 Total Adjusted (Primary) Trips - 253 179 158 220 Net Difference (New Minus Previous Trips) - -76 +81 +18 -93 +5 -75 5/19/2021 210239: Scotts Hill Apartments – Trip Generation 3 The results in Table 3 show a slight increase in 24-hour trips (+70), a slight increase in net AM peak hour trips (+5), and a significant reduction in net PM peak hour trips (-75). The June 2019 TIA identified roadway improvements that would be required for the Scotts Hill Medical Park development. The current trip generation shows that the proposed uses have a comparable or lower trip generation than the previous TIA. As a result, the previously determined roadway improvements are expected to remain adequate. Please let us know if you need additional information. Sincerely, ______________________ Nick Liguori, P.E. nliguori@davenportworld.com 804-554-0910 SEAL 5/19/21  FIGURE 1 NEW SKETCH PLAN    FIGURE 2 PREVIOUS SITE PLAN