Masonboro Commons Starbucks Coffee– 6400 Carolina Beach Road – TRC Review
Page | 1
To: Tommy Scheetz, P.E., Headwaters Engineering of the Cape Fear PLLC
From: Katherine May, Development Review Planner
Date: April 2, 2025 TRC
PID#: R07900-001-001-008
Egov# SITECN-25-000063
Subject: 6400 Carolina Beach Road – Masonboro Commons Starbucks Coffee - TRC Review
The following comments have been received for the April 2, 2025, TRC meeting. Additional comments
may be made upon further review of subsequent revisions.
Please note: following the TRC meeting, a revised site plan addressing each of the below items must be
resubmitted prior to receiving site plan approval.
Planning, Katherine May 910-798-7443
1. General Comments
a. The site is zoned B-2
b. The use is a restaurant - (Starbucks Coffee). As a note, the New Hanover County Ordinance
considers coffee shops restaurants- it does not break them out into a separate use.
2. UDO Section 5.1, Parking and Loading
a. The use of restaurant requires 6 parking spaces per 1,000 sq ft of seating area. This site
provides more than adequate parking.
b. Will there be a shared parking agreement?
3. UDO Section 5.2, Traffic, Access and Connectivity
a. Please note that no building permit for any structure shall be issued which requires
NCDOT approval for a Driveway Permit until NCDOT has issued the permit approval.
Evidence of approval shall accompany the application for building permit.
b. This project has an approved TIA- please reference the WMPO comments for required
improvements.
4. UDO Section 5.3, Tree Retention
Masonboro Commons Starbucks Coffee– 6400 Carolina Beach Road – TRC Review
Page | 2
a. Please verify that trees being removed from the stormwater pond do not require a tree
removal permit.
b. Note: Land disturbance permits can be issued by county Engineering before a Tree
Removal Permit is approved by Planning. However, any trees removed before the Tree
Removal Permit is issued may result in enforcement action under Section 5.3.2 of the
Unified Development Ordinance to include prohibiting any development of the site for 3
to 5 years.
5. UDO Section 5.4, Landscaping and Buffering
a. Landscape plan is missing. Additional comments for landscaping and buffering will be sent
once the landscape plan is submitted.
b. 5.4.4: Screening
i. Screening of the dumpster must be at least 8 feet high. A combination of
materials can be used.
c. 5.4.5.C: Standards for Parking Lot Interiors
i. Landscaped areas in the interior of parking lots shall be equal to eight percent of
the total area to be used for parking, loading, automobile sales, driveways,
internal drive aisles, and other vehicular or pedestrian use.
ii. Landscaping islands, either separate from or protruding from perimeter
landscaping strips, shall be a minimum of 12 feet in width measured from back
of curb to back of curb.
d. 5.4.6.B: Street Yard Standards
i. 25 square feet for every linear foot of street yard frontage
ii. For every 600 square feet of street yard area on average, the following
landscaping shall be provided: One canopy/shade tree or if overhead power
lines are located above the street yard, three (3) understory trees, six shrubs, 12
inches in height at time of planting.
e. 5.4.7: Foundation Plantings
i. The foundation planting area shall be 12 percent of the area of the first-floor
building face, or building face up to 25 feet in height, whichever is less, adjacent
to the parking area or internal drive
6. UDO Section 5.5, Lighting
a. Please note that a lighting plan is not required for TRC approval, but will be required prior
to issuance of construction plan approvals.
Masonboro Commons Starbucks Coffee– 6400 Carolina Beach Road – TRC Review
Page | 3
b. Is any lighting proposed for the site?
7. UDO Section 5.6, Signs
a. For any signs on the site, please submit for a sign permit, referencing Section 5.6 of the
UDO for standards.
8. UDO Section 5.7, Conservation Resources
a. The New Hanover County Conservation Resource Map does not indicate any Conservation
Resources on this property.
9. UDO Article 9, Flood Damage Prevention
a. Property is not in the flood plain.
NHC Fire Services, David Stone 910-798-7458
1. Fire is requesting the developer to add a fire hydrant at the corner of Carolina Beach Road and
the shopping center access road north of the Starbucks. This would assist in providing a better
response in the event of a fire at this location.
NHC Soil & Water Conservation, Dru Harrison 910-798-7130
1. Comments are attached.
NHC Engineering, Galen Jamison 910-798-7072
1. A land disturbing issued by the County is required for this project. Please digitally submit the
permit application documentation with requisite review fees for County issued permit directly
to gjamison@nhcgov.com. Application and forms can be found at
https://www.nhcgov.com/249/Sediment-Erosion-Control.
2. A County stormwater permit issued by the County is required for this project. Please indicate in
plan view the anticipated location and size of the stormwater control measure (SCM). Please
digitally submit the permit applications documentation with requisite review fees to the COAST
online permit portal (https://newhanovercountync-
energovpub.tylerhost.net/apps/selfservice#/home). Applicable forms can be found at
https://www.nhcgov.com/251/Stormwater however the application form is not required as the
information will be gathered by the COAST portal.
3. Please contact the State DEQ office for the stormwater permit modification requirements. It is
anticipated a major permit modification will be required to SW8900509.
Masonboro Commons Starbucks Coffee– 6400 Carolina Beach Road – TRC Review
Page | 4
NHC Environmental Health, Dustin Fenske 910-798-6732
1. Site is on public water. Must submit restaurant plans to the NC Environmental Health Plan
Review Unit for approval. Restaurant plans must be approved prior to building permit release.
2. Site is on public sewer.
NHC Addressing, McCabe Watson 910-798-7068
1. Please contact me for address assignments following TRC approval.
Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620
1. CFPUA TRC Comments provided are preliminary comments only.
2. Utility Plan review will be required by CFPUA. CFPUA is moving toward becoming paperless.
When ready to submit plan review package, upload all documents to
https://www.cfpua.org/FormCenter/Engineering-3/Engineering-Plan-Review-103.
3. CFPUA water available; CFPUA sewer available via a private FM extension connecting to public
manhole.
4. CFPUA Meter Sizing Form will be required.
5. Capacity is dependent on the analysis of the pipe collection system (gravity and force mains).
6. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE Application
Form and a Preliminary Plan, this determination does not guarantee capacity.
7. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the
plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the
Authority.
NCDOT, Nick Drees 910-343-3915
1. Comments are attached.
WMPO, Greer Templer 910-341-0107
1. Comments are attached.
Army Corps of Engineers, Brad Shaver 910-251-4611
1. No comments.
NCDEQ, Kelsey Beachman 910-796-7270
1. This project is not located within the CAMA AECs. However, the sites are located within a coastal
county per the CAMA, so if an IP is required by the USACE the DCM would review it through a
Federal Consistency Determination.
Masonboro Commons Starbucks Coffee– 6400 Carolina Beach Road – TRC Review
Page | 5
Comments not received at this time from:
Emergency Services & E911, Steve Still
NCDEQ, Chad Coburn
NCDEMLR, Dan Sams
DCM, Tanya Pietila
United States
Department of
Agriculture
A product of the National
Cooperative Soil Survey,
a joint effort of the United
States Department of
Agriculture and other
Federal agencies, State
agencies including the
Agricultural Experiment
Stations, and local
participants
Custom Soil Resource
Report for
New Hanover
County, North
Carolina
Natural
Resources
Conservation
Service
Map Unit Legend (6404 Carolina Beach Rd)
Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI
Kr Kureb sand, 1 to 8 percent
slopes
1.3 100.0%
Totals for Area of Interest 1.3 100.0%
Custom Soil Resource
Report Soil Map (6404
Carolina Beach Rd)
37
7
7
79
0
37
7
7
80
0
37
7
7
81
0
37
7
7
82
0
37
7
7
83
0
37
7
7
84
0
37
7
7
85
0
37
7
7
86
0
37
7
7
87
0
37
7
7
88
0
37
7
7
79
0
37
7
7
80
0
37
7
7
81
0
37
7
7
82
0
37
7
7
83
0
37
7
7
84
0
37
7
7
85
0
37
7
7
86
0
37
7
7
87
0
37
7
7
88
0
232
420
232
430
232
440
232
450
232
460
232
470
232
480
232
490
232420 232430 232440 232450 232460 232470 232480 232490
34° 6' 27'' N
77
°
54
'
2'
'
W
34° 6' 27'' N
77
°
53
'
59
'
'
W
34° 6' 24'' N
77
°
54
'
2'
'
W
34° 6' 24'' N
77
°
53
'
59
'
'
W
N Map projection: Web Mercator
Corner coordinates: WGS84 Edge tics: UTM Zone 18N WGS840 20 40 80 120Feet05102030Meters
MAP INFORMATION
The soil surveys that comprise your AOI were mapped at
1:15,800.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil
line placement. The maps do not show the small areas of
contrasting soils that could have been shown at a more detailed
scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source of Map: Natural Resources Conservation Service Web
Soil Survey URL:
Coordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves
direction and shape but distorts distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more accurate calculations of distance or
area are required.
This product is generated from the USDA-NRCS certified data as of the version date(s) listed
below.
Soil Survey Area: New Hanover County, North Carolina Survey Area Data: Version 26, Sep
9, 2024
Soil map units are labeled (as space allows) for map scales
1:50,000 or larger.
Date(s) aerial images were photographed: Nov 8, 2022—Dec 1, 2022
The orthophoto or other base map on which the soil lines were compiled and digitized probably
differs from the background imagery displayed on these maps. As a result, some minor shifting
of map unit boundaries may be evident.
TO: New Hanover County Planning Department, New Hanover SWCD, March 24th,
2025
FROM: Dru Harrison, Director
RE:
I HAVE REVIEWED THIS PLAN AS REQUESTED AND HAVE THESE
COMMENTS: The soils are predominantly Kureb sand (Kr).
According to the booklet, “Wilmington/New Hanover Classification of soils for Septic
Tank Suitability, Kureb is a Class I soil.
The Soil Survey of New Hanover County lists Kureb as excessively well drained.
Kureb is on the Hydric Soils “B” list, which means it may contain areas of wetland. It
should be noted, according to the Soil Survey of New Hanover County, the limitation for
dwellings with or without basements and for small commercial buildings is severe for all
of the soils on this site. The limitations are due to flooding and/or wetness. An adequate
drainage and maintenance plan is needed for suitable housing.
The U.S. Army Corps of Engineers has federal jurisdiction over 404 Permits and the
NCDEHNR, Dept. of Water Quality, has state jurisdiction over 401 Permits under the
Clean Water Act. Before disturbing possible wetland areas, developers should contact
these agencies to stay in compliance with State and Federal regulations.
STATE OF NORTH CAROLINA
DEPARTMENT OF TRANSPORTATION
JOSH STEIN J.R. “JOEY” HOPKINS
GOVERNOR SECRETARY
Mailing Address:
NC DEPARTMENT OF TRANSPORTATION
DISTRICT 3 ENGINEER’S OFFICE
5911 OLEANDER DRIVE, SUITE 101
WILMINGTON, NC 28403
04-11-03 COURIER
Telephone: 910-398-9100
Customer Service: 1-877-368-4968
Website: ncdot.gov
Location:
5911 OLEANDER DRIVE, SUITE 101
WILMINGTON, NC 28403
Memorandum
To: New Hanover County Technical Review Committee
Date: March 10, 2025
Subject: Meadows Commercial Lot – 4737 Castle Hayne Road
________________________________________________________________________
These are preliminary comments and are based on the plans as submitted for the proposed
site. They are subject to further review upon receipt of any additional information.
Subsequently, additional comments and/or requirements may be necessary for this site.
General Comments:
NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT
Online Portal.https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx
NCDOT Driveway Permit:
An NCDOT Driveway Permit is required. Submit plans in accordance with pages 14 and
15 of the Policy on Street and Driveway Access to North Carolina Highways to include
access locations within 500’ of the proposed access on both sides of the State Road.
Submit to the local NCDOT District Engineer’s Office.
x Refer to the NCDOT checklist (included) for required documents and site plan
information.
NCDOT Encroachment Agreement:
An NCDOT Encroachment Agreement is required for any utility connections or
installations within the NCDOT right-of-way (form 16.6).
x Refer to the NCDOT UAM Manual and the NCDOT encroachment checklist for
required documents and site plan information.
An NCDOT Encroachment Agreement is required for any sidewalk or multi-use paths
installed within the NCDOT right-of-way (form 16.6).
Mailing Address:
NC DEPARTMENT OF TRANSPORTATION
DISTRICT 3 ENGINEER’S OFFICE
5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403
04-11-03 COURIER
Telephone: 910-398-9100
Customer Service: 1-877-368-4968
Website: ncdot.gov
Location:
5911 OLEANDER DRIVE, SUITE 101
WILMINGTON, NC 28403
Site Plan Comments:
Include/update the NCDOT Standard Drawings (2024) that are applicable to the
development.
Sight Triangles and Sight Distance:
x Show and label the 10’ X 70’ NCDOT sight triangles.
o No obstructions shall be placed within the NCDOT sight triangles.
x Show and label the stopping sight distance.
o No obstructions shall be placed within the stopping sight distance.
Identification Signing and Landscaping:
x Identification signing or landscape vegetation within the median and the sight
distance triangle must not obstruct the driver’s line of sight. No landscaping or
signing will be allowed to exceed 42 inches in height, measured from the Edge of
Pavement (EOP) within the median or sight triangle.
x All pylon signs in the median or sight distance triangle must provide a vertical
clear sight zone between 3 feet-6 inches and 10 feet-0 inches measured from the
EOP. Signing located within a clear recovery area shall be of a “breakaway
design.”
x Only low growing shrubbery, consistent with the NCDOT’s landscaping policies,
as contained in the publication “Guidelines for Planting Within Highway Right of
Way,” will be allowed within a landscaped median and the sight distance triangle
at the entranceway to a development, whether the street or driveway connection to
the State Highway System is designated as a public facility or not. Landscaping
within the right-of-way and sight distance triangles may require additional
approval by the District Engineer.
Label the internal protection stem length for the proposed driveway connection.
x Measured from the right-of-way line.
You can coordinate with the district office with any questions 910-398-9100.
NCDOT | Division 3 | District 3 Project Name:_____________________________ Date:_______________
Applicant Checklist NCDOT Checklist
Driveway Application Process and Site Plan Requirements
ALL APPLICATIONS SHALL BE ACCOMPANIED BY COMPLETE AND DETAILED SITE PLANS THAT ADHERE TO THE POLICIES LISTED IN THE POLICY ON STREET AND
DRIVEWAY ACCESS TO NORTH CAROLINA HIGHWAYS AND THIS DOCUMENT. FAILURE TO ADHERE TO THESE POLICIES WILL RESULT IN THE RETURN OF THE
APPLICATION TO THE APPLICANT FOR REVISION.
***THE NCDOT WILL NOT BEGIN THE REVIEW PROCESS ON INCOMPLETE APPLICATIONS***
Electronic Pre-Submittals
In an effort to save time and resources, we are happy to provide an initial assessment of a driveway permit submittal’s plans via email to
identify any major issues up front. This initial assessment can be followed up with a submittal of one digital copy of the plans along with all
other required documents.
All Permit applications shall be submitted through the online portal https://connect.ncdot.gov/site/Permits/Pages/default.aspx
In the notify email section of the portal application please include the District Office email (Div3Dist3@ncdot.gov). See the last pages for further instruction.
Online resources:
•NCDOT Policy on Street and Driveway Access to North Carolina Highways:
https://connect.ncdot.gov/projects/Roadway/RoadwayDesignAdministrativeDocuments/Policy%20on%20Street%20an
d%20Driveway%20Access.pdf
•NCDOT Policies and Procedures for Accommodating Utilities on Highway Rights of Way:
https://connect.ncdot.gov/municipalities/Utilities/Pages/UtilitiesManuals.aspx
•Electronic Forms Database:
https://connect.ncdot.gov/Pages/default.aspx
1)
a.Cover Letter
Include contact information for applicant and engineer, including email address, mailing address, and phone
number. Include the parcel number(s), description of all phases of the development and future land uses to be
served by the permit, and a description of the adjoining land owned or controlled by the applicant.
b.NCDOT Street and Driveway Access Permit Application (form downloadable via link below)
https://connect.ncdot.gov/resources/BusinessForms/TEB-65-04.doc
c.$50.00 Inspection Fee Per Access Point
Attach to Permit Application form (not applicable for municipalities, churches, and schools)
d.NPDES Stormwater Permit Compliance Certification (form downloadable via link below)
https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/NPDESstatement.doc
e.Verification of Compliance with Environmental Regulations (form downloadable via link below)
https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/VCER-1.pdf
f.Site Plans (to include the “Master Plan” of a tract even if only a small portion is being developed first) Additional
site plan requirement details can be found in section 2 of this document.
g.Design Plan Requirements for projects involving roadway improvements
If roadway improvements are required as part of the permit, then roadway plans, pavement marking plans,signing plans, and traffic control plans will be required - See Section 6 for more information
Y N n/a
Engineering Studies
The applicant may be required by the District Engineer to submit studies based on, but not limited to, the parameters outlined
herein. If study requirements of the local government agency are more restrictive than the NCDOT requirements, then local
government requirements will govern. However, this does not imply that the NCDOT is obligated to approve entrance designs
that are too constrictive to allow smooth and safe traffic flow. All studies including, but not limited to, Traffic Impact Analyses
(TIA), traffic signal studies, and drainage studies, must be prepared under the direct charge of and sealed by a North Carolina
licensed Professional Engineer.
Section 1: Requi
red Documents
|Required documents to accompany all Initial Driveway Application Submittals
Please note that these are the minimum requirements of all driveway permit applications.
All required documentation shall be submitted through the online portal as PDF files, with the exception of the
Performance and Indemnity Bond and the $50 Inspection Fee(s), these should be mailed or delivered to 5501
Barbados Blvd, Castle Hayne, NC 28429.
If a Traffic Impact Analysis and/or roadway improvements are deemed necessary as a condition of the permit, there
may be additional submittal materials required.
State of North Carolina | Department of Transportation | Division 3 | District 3
5501 Barbados Blvd, Castle Hayne, NC 28429
Form Updated 10/15/2021 (910) 398-9100 T NCDOT Permit #___________________
Y N n/a
Section 1: Required Documents (continued)
2)Required documents to accompany all Driveway Applications PRIOR TO FINAL APPROVAL
a.Site Plans
One (1) digital copy (PDF) unless otherwise requested by the District Office. Additional site plan requirement
details can be found in section 2 of this document.
b.Performance and Indemnity Bond Information/Forms
See last page of document for bond information and forms
c.Performance and Indemnity Bond Amount
100% of the cost of the work within NCDOT Right-of-Way (R/W) based on the attached estimate determined by
the applicant's engineer and approved by the District Engineer. Bond hold letter required for for municipalities,
churches, and schools. See pages 101-105 in the Policies and Procedures for Accommodating Utilities on Highway
Rights of Way for acceptable bond types
d.Radius Encroachment Letter (if applicable)
If driveway radius encroaches on the frontage of an adjacent property, a Radius Encroachment will be required
e.Hold Harmless Letter (if applicable)
If the Permit is within the limits of an active NCDOT project, a Hold Harmless letter from the NCDOT contractor will
be required. If the project is in preconstruction, coordinate with the Department's Project Development Unit
Section 2: General Site Plan Requirements | All site plans shall include and show, at a minimum, the items listed below
Page numbers reference the NCDOT Policy on Street and Driveway Access to North Carolina Highways
1)Drawn to a scale of 20, 30, 40, or 50 feet per inch and the scale shall be shown
2)North arrow, vicinity map, date of plan, and date of most-recent revision if applicable
3)Contact information of applicant and engineer, including mailing address, phone number, and email address
4)Show R/W lines, highway control of access, and property lines
5)All existing utilities (including handholes) and easements
6)R/W width
7)Existing posted speed limit(s) and design speed limit(s)
8)Show all property lines, intersections, signals, signal loops, railroads, or crossovers within 500’ in all directions of
the property lines of the proposed development
9)Show location of sidewalks, crosswalks, greenways, multi-use paths, curb ramps, railroads, bus stops, and any
other relevant transportation facilities in the development area
10)Include a plan sheet showing full site build-out and land use
11)Buildings shown with “gross leasable area”
12)Width of property frontage
13)Distance from R/W to buildings and gasoline service islands
14)Distance from R/W to existing/proposed Edge of Pavement (EOP) (pages 32 & 34)
15)All streams, bridges, retaining walls, signs, or other fixed objects such as trees, utility poles, traffic signals, etc.
Section 3: Driveway Plan Requirements
|
All driveway plans shall include and show, at a minimum, the items listed below
1)Provide comprehensive survey within the existing R/W on both sides of the road for a distance of 500’ in all
directions from the development’s property lines. Provide additional hydraulic survey data to the nearest storm
water inlet/outlet including ditch lines and storm water pipes, if located outside of the 500' distance.
2)Lane configurations and widths of all existing and proposed driveways, roadways, and adjacent roadways
3)All driveway widths (2-way: 20’ minimum, 36’ maximum | 1-way: 12’ minimum, 24’ maximum | with island: 14'ingress, 18' egress) (pages 50 & 77)
4)Driveway Profile - In shoulder sections, maintain minimum 2% fall from edge of travel way for required
shoulder width distance Primary: 8’ minimum | Secondary: 6’ minimum
5)All existing and/or proposed driveway radii (20’ minimum, 50’ maximum, 30’ typical) (pages 34 & 51)
In curb and gutter sections, use City of Wilmington flare (SD 3-03.3) - (see attached)
In shoulder sections, show grades at the EOP and centerline
6)No curbing is allowed within NCDOT R/W along shoulder sections except as part of a driveway island (page 31)
7)Driveway angles of approach to existing roadway (90° preferred, 75°-90° required for 2-way driveways, 45°-90°
allowed for right-in/right-out on a case-by-case basis) (page 51)
8)Driveway Profile (pages 42- 43)
Y N n/a Y N n/a
□□ □□ □ □
Y N n/a Y N n/a
Y N n/a Y N n/a
Section 3: Driveway Plan Requirements (continued)
9)Driveway Pavement Cross Section (to be in place from EOP to edge of R/W)
Asphalt: 8” ABC stone and 1.5” S9.5B
Concrete: 6” of concrete
10)Driveway Offset (driveway EOP to property line; page 75): Minimum: 20’
11)Corner Clearance (radius point to radius point; page 52)Minimum: 50’ Desirable: 100’ or Municipal std.
12)Minimum 10’x70’ sight triangles at driveways (measured from and along the R/W line) (page 31)
13)Sight Distance (length of sight-distance in both directions shown for each driveway; pages 27-29)
14)Driveways should be aligned with existing opposing driveways or correct offset should be provided (pages 40-41)
15)Distance between driveways being requested (if applicable; page 51)
16)Minimum internal storage areas with specified queues (pages 31-33)
17)Minimum protected driveway stem(s) provided and indicated (pages 33-34)
18)Indicate any gated entrances (100’ minimum setback from R/W required) - traffic queuing study may be required
|
Section 6: Roadway Plan Requirements
If off-site improvements are required, roadway plans shall show, at a minimum, the items below
1)Full width typical sections must be shown (paved shoulders to match the typical section of the adjacent roadway)
2)Minimum Asphalt Typical Section (for turn lanes and/or paved shoulders)
Adjacent recently-completed or upcoming TIP projects w/ different typical sections may supersede those below
•Primary Routes (US & NC) and Secondary Routes with Annual Average Daily Traffic (AADT) ≥10,000
5.5” B25.0C, 3” I19.0C, 1.5” S9.5C; any overlay of existing pavement is to be a minimum of 1.5” S9.5C
•Secondary Routes with AADT<10,000
5.5” B25.0C, 1.5” S9.5B; any overlay of existing pavement is to be a minimum of 1.5” S9.5B
3)Pavement overlay is required if modification of existing pavement markings and/or lanes is necessary
The grinding of pavement markings will not be allowed
4)Shoulder Widths (Paved + Unpaved) Primary: 8’ minimum | Secondary: 6’ minimum
5)Ditch Slopes - front and back slopes - minimum 3:1 or flatter
6)Indicate existing roadway grade
7)All taper lengths and deceleration lengths should be appropriately designed for the given design speed (page 78)
8)All turn lanes should be designed according to the Driveway Manual and Roadway Standard Drawings (page 79)
See 1205.04 Sheets 1 & 2 and 1205.05 Sheet 1 of the Roadway Standard Drawings for details
9)Pavement marking and signing plans are required - plans must be approved by Division Traffic Services
10)Traffic control plans are required - Detailed phasing plans may be required based on project type and location
11)New and/or revised signal plans must be included for new installations and if signal modifications are required
All signal plans must be reviewed and approved by Division Traffic Services and the Signal Design Unit. A Traffic
Agreement must be completed to facilitate the review. Contact Division Traffic Services at (910) 341-2200.
|
Section 4: Drainag e Requirements
All drainage features on NCDOT Right-of-Way shall adhere to, at a minimum, the items listed below
Section 5: Internal Circ ulation Requirements
|All internal circulation details shall adhere to, at a minimum, the items listed below
1)Interior driveway channelization stems
Minimum 100’ from the ROW or at the discretion of the District Engineer
2)Traffic flow pattern
3)Traffic control devices
4)Pavement Markings
Y N n/a Y N n /a
Y N n/a Y N n/a
Y N n/a Y N n/a
Y N n/a Y N n/a
1)Pipe Cover Minimums (measured from top of pipe to subgrade)
High Density Polyethylene (HDPE): 24” | Corrugated Aluminum (CAP): 12” | Reinforced Concrete (RCP): 12”
2)Pipe End Treatment (see Roadway Design Manual 5-20, B-2)
Pipes ≤24" on multilane highways posted above 45mph require Parallel Pipe End Sections See 310.02 and
310.04 of the Roadway Standard Drawings for details
Pipes >30" on multilane highways posted above 45mph require guardrail
Pipes ≥36" require an endwall on the inlet end
3)All proposed Drainage is to be provided inside existing R/W. Otherwise, additional R/W or a permanently
dedicated drainage easement will be required to accommodate the proposed project drainage
4)All sizes, types, and invert elevations of existing/proposed pipes and drainage structures must be shown(see Sec.3 #1 for survey requirements)
5)Provide spot elevations along frontage of driveway (at EOP and centerline)
6)Provide grades and spot elevations for existing and proposed ditches
7)Show how drainage will be accommodated along property frontage(District Engineer may require applicant to provide drainage calculations when warranted)
C/L
EOTEOP
P/L
R/WR/W
R/W
EOP
EOP
EOP
EOP
NTS
R/W
P/L
DRAINAGE FLOW
DRAINAGE FLOW
DRAINAGE FLOW
SHOULDER WIDTH
SHOULDER WIDTH
SHOULDER WIDTH
SHOULDER WIDTH
S IGHT T R IANGLE
10 ' BY 70 'S I GHT T R I AN G L E10' B Y 70'
DRIVEWAY
RR MIN. 30'MIN. 30'
NO ROADWAY IMPROVEMENT
COMMERCIAL DRIVEWAY WITH
NORMAL CROWN ROADWAY
6" LOWER THAN THE EDGE OF PAVEMENTMIN 2% FALL AWAY or
20' AWAY FROM THE PROPERTY LINEDRIVEWAY SHALL BE LOCATED AT LEAST
PIPE/TYPE/SIZE
WIDTH
CON
CR
ET
E
/ASP
HA
LT
LOCAL NAME ROAD POSTED SPEED ( ) MPH WIDTH WIDTHSR NUMBER
SITE ADDRESS:TAX PARCEL #
20191115
PARALLEL END S.D. 310.02
INVERT ELEVATION
PARALLEL END S.D. 310.02
INVERT ELEVATION
20' AWAY FROM THE PROPERTY LINEDRIVEWAY SHALL BE LOCATED AT LEAST
OR 500' OF XYZ SURVEY DATA PAST THE PROPERT LINENEAREST OUTFALL ELEVATION
OR 500' OF XYZ SURVEY DATA PAST THE PROPERT LINENEAREST OUTFALL ELEVATION
Cast
l
e
H
a
y
n
e
R
o
a
d
(
U
.
S
.
H
w
y
.
1
1
7
)
Sondey
R
o
a
d
/
S
.
R
.
1
3
3
4
(Var
i
a
b
l
e
W
i
d
t
h
P
u
b
l
i
c
R
/
W
)
N 66°2
4
'
2
5
"
W
1
4
0
.
0
8
'
N 28
°
2
7
'
3
5
"
E
2
2
6
.
9
3
'
S 69°58'25
"
E
1
7
6
.
1
2
'
(50' R/
W
)
48'' Water Oak
32'' Live Oak
(1,50
0
s
.
f
.
)
Spac
e
30'
50'
30'
New
"
F
l
e
x
"
(1,50
0
s
.
f
.
)
Spac
eNew
"
F
l
e
x
"
20'
B
l
d
g
.
S
e
t
b
a
c
k
&
T
r
a
n
s
i
t
i
o
n
a
l
B
u
f
f
e
r
20' Tran
s
i
t
i
o
n
a
l
B
u
f
f
e
r
30' Side
S
e
t
b
a
c
k
Lot 1
16,551 s.f.±
n/f
Ryan P. &Amanda D. Mekler
D.B. 6246-464Zoning: RALand Use: Vacant
n/f
Evelyn PotterDavis Heirs
D.B. 6559-2347Zoning: RALand Use: Residential
n/fRyan
Griffin
D.B. 5904-2713Zoning: R-20Land Use: Residential
n/f
Richard &Dara Kern
D.B. 6041-82Zoning: R-20Land Use: Residential
n/f
AliciaVasquez
D.B. 6258-2144
Zoning: RALand Use: Residential
150.
0
4
'
76.88
'
20' B
l
d
g
.
S
e
t
b
a
c
k
&
T
r
a
n
s
i
t
i
o
n
a
l
B
u
f
f
e
r
25' S
t
r
e
e
t
S
e
t
b
a
c
k
&
B
u
f
f
e
r
y
a
r
d
25' St
r
e
e
t
S
e
t
b
a
c
k
25' Street
S
e
t
b
a
c
k
New15' x 30'Tire Shed
W
24'
62'
25'
31'
S 53°
5
6
'
8
"
E
2
2
6
.
9
3
'
157.8
3
'
IG
MC
IV
IC
MC
IGSM
IV
IC
SM
SM
SM
IL
MC-P
IV
R2
5
'
R25'
R1
0
'
R10'
18'
9'
48'
IC
34'
R5
'
R5'
2% FROM EOP
2%
F
R
O
M
E
O
P
IG
FFE
=
2
4
.
0
5
22
23
23
22
23
23
10-FT
S
E
W
E
R
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
S 53°5
6
'
0
8
"
E
159.2
7
'
2221
22
21
23
S 36°3
8
'
3
5
"
W
1
1
8
.
4
8
'
S 36°
3
8
'
3
5
"
W
1
2
4
.
8
7
'
MA
REVISION NO.
OF:
DATE:
SCALE:
DRAWN BY:
47
3
7
C
A
S
T
L
E
H
A
Y
N
E
R
D
.
,
C
A
S
T
L
E
H
A
Y
N
E
,
N
C
2
8
4
2
9
THE
S
E
D
R
A
W
I
N
G
S
A
N
D
S
P
E
C
I
F
I
C
A
T
I
O
N
S
A
R
E
T
H
E
P
R
O
P
E
R
T
Y
A
N
D
C
O
P
Y
R
I
G
H
T
O
F
D
O
G
W
O
O
D
L
D
,
P
L
L
C
A
N
D
S
H
A
L
L
N
O
T
B
E
U
S
E
D
O
N
A
N
Y
O
T
H
E
R
W
O
R
K
E
X
CEP
T
B
Y
A
G
R
E
E
M
E
N
T
W
I
T
H
D
O
G
W
O
O
D
L
D
,
P
L
L
C
.
PRO
V
E
R
B
S
1
6
:
3
C
O
M
M
I
T
Y
O
U
R
W
O
R
K
S
T
O
T
H
E
L
O
R
D
A
N
D
Y
O
U
R
P
L
A
N
S
W
I
L
L
B
E
E
S
T
A
B
L
I
S
H
E
D
.
ME
A
D
O
W
S
C
O
M
M
E
R
C
I
A
L
PA
U
L
&
D
E
A
N
N
E
M
E
A
D
O
W
S
47
1
7
I
N
D
I
A
N
C
O
R
N
T
R
A
I
L
CA
S
T
E
H
A
Y
N
E
,
N
C
2
8
4
2
9
NORTHCAROLINA
JA
MEBANCH SM
PROFESSION
ENGINEERSEALAL
SR
ITH034354
DOGWO O D LD,
P
LLC
5872-P .CIL CN
205 Sierra Dr.Wilmington, NC 28409(910) 264-1071
PROJ. NO.24106.DLD
JBS
SHEET:
02/27/25
FINAL-TRC PLANNOT FORCONSTRUCTION
1/27/25
CS100
3 5
SITE ANDLANDSCAPEPLAN
0 10 20 40 80
S C A L E: 1" = 20'
G R A P H I C S C A L E
N O R T H
20 SCALE
3. Current Zoning District: RA
2. Tract Area: 36,372 s.f.± (0.84 ac.)
1. New Hanover County Parcel No.:
General Notes:
4. Comprehensive Plan Classification:Community Mixed-Use
322112.95.1866
Development Data:
[PID R1700-002-007-000]
Total Building Area - 7,070 s.f.±
New Building Parking - (@ 2.5 spaces / 1000 s.f. GFA)Min. Spaces Req'd. = 8** Spaces Prov'd. = 9 ** (2 garage spaces)
Max. Proposed New Building Height - 1-Story / 25'
Proposed District - (CZD) B-2
2. This property is not impacted by any AEC.
3. There is no evidence of Conservation OverlayResources.
4. This site is not impacted by any recognizedhistoric or archeological significance.
5. No cemeteries were evidenced on the site.
6. Existing regulated trees have been field located.
7. There is no evidence of jurisdictional wetlands.
8. There is no evidence of endangered species orhabitat issues on the site.
Site Inventory Notes:
9. This tract is not impacted by any Special Flood Hazard
10. The site runoff will flow into the Prince George
1. Soils: Se (Segate fine sand)
Area as evidenced on FEMA Map 3720322100K,dated August 28, 2018.
Creek watershed.
General Utility Notes:
1. Water service will be provided by a private, on-site well. Sanitary sewer service is provided by a
gas & telephone shall be installed underground.
3. Solid waste disposal will be by roll-out cart pickup.
2. All utility services, such as electric power, CATV,
private on-site septic system. No Fire Hydrants
Proposed New (Lot 2) - +3,000 s.f.±
Ex. Bldg. Addition (Lot 1) - + 450 s.f.±
Existing (Lot 1) - 5,200 s.f.±Ex. Shed to be Removed (Lot 1) - -1,580 s.f.±
(No Scale)
Vicinity Map
Site
N
E
S
W
NC H
W
Y
1
1
7
-
C
A
S
T
L
E
H
A
Y
N
E
R
O
A
D
PARM
E
L
E
R
D
SODNEY
R
D
Lot 2 Impervious Data:Rooftop - 3000 s.f.Parking Lot - 3600 s.f.Sidewalks - 300 s.f.DOT Driveway 1100 s.f.
Total Lot 2- 8,000 s.f.
in the area.
Lot 1 Impervious Data:Ex. Rooftop - 4950 s.f.Ex. Concrete-Gravel Yards - 7675 s.f.
Total Existing - 12,625 s.f.
Existing Shed Removed - -1500 s.f.New Building Addition - +450 s.f.
Total Lot 1 - 11,575 s.f.
Lot 1 & 2 Impervious Total: 19,575 s.f.
NCDEQ Permit Exclusion:
12,625 s.f.Lot 1 and 2 Existing Total:Lot 1 & 2 Impervious Total: 19,575 s.f.
Lot 1 & 2 Impervious NET: 6,950 s.f.
LANDSCAPE PLANT SCHEDULE:
RIBBON CURB(SEE DETAILS)
ACCESSIBLESPACE, SIGN,AND AISLE(SEE DETAILS)
PROPOSED SEPTICPANEL BLOCK TRENCHES(SEE SEPTIC PERMIT)
PROPOSED PERVIOUSPAVEMENT (SEE DETAILS)
5-ft MIN. SIDEWALK, TYP.
PROPOSED WELL BYOTHERS (SEE DETAILS)
6-FT SHADOWBOX FENCE
IF EXISTING VEGETATION IS 100% OPAQUE,PROPOSED PLANTINGS MAY BE OMITTEDTO BE VERIFIED WITH ZONING INSPECTOR
10X70 SITE DISTANCETRIANGLES, TYP.
10X70 SITE DISTANCETRIANGLES, TYP.Rezoning Conditions (CZD) CB [Case Z24-05]
i. The proposed rezoning’s principal use shall be limited to: AnimalGrooming Services, Contractor Office (with no outdoor storage),Offices for Private Business &Professional Activities, InstructionalServices & Studios, Personal Services, General Retail Sales, MinorVehicle Service Station, and Warehousing.
ii. The attached shed that encroaches into the rear setback is to beremoved, bringing Dad’s Tire Store into compliance with requiredsetbacks.
iii. A septic and well easement approved by New Hanover CountyEnvironmental Health shall be recorded with the register of Deedsguaranteeing access and maintenance for the existing septic systemand any future improvements. Environmental Health approval ofthe septic system and well shall be required prior to issuance ofconstruction permits for the flex commercial space.
iv. Exterior lighting including luminaries and security lighting shall befully cutoff fixtures that are directed downward in compliance withFigures of the UDO. In no case shall lighting be directed at or abovea horizontal plane through the lighting fixture.
v. The two Significant trees identified on the concept plan shall bepermanently retained on site.
LANDSCAPE REQUIREMENTS:
STREETYARD: ALONG CASTLE HAYNE ROAD (25-SF PER FRONTAGE LENGTH)SIDE: TYPE A, OPTION 1 TRANSITIONAL BUFFERREAR: TYPE A, OPTION 1 or 3 TRANSITIONAL BUFFER
STREETYARD: REQUIRED: PROVIDED:LENGTH (FT): 92' 92'
AREA (SF) (25-ft): 2300 2300CANOPY TREES (1 PER 600SF): 5 5UNDERSTORY TREES: 0 0SHRUBS (6 PER 600SF): 30 30
SIDE YARD: PROVIDED:TOTAL PERIMETER LENGTH (FT): 140CANOPY TREES: 4UNDERSTORY TREES: 12SHRUBS: 23
REAR YARD WITH FENCE: PROVIDED:TOTAL PERIMETER LENGTH (FT): 150CANOPY TREES: 5UNDERSTORY TREES: 15SHRUBS: 0NOTE: OWNER WANTS FENCE ON PROPERTY LINE AND SEPTIC SYSTEMREQUIRES ENCROACHMENT INTO BUFFER FOR SOILS
FOUNDATIOn PLANTS (FRONT FACE)REQUIRED:PROVIDED:LONG BUILDING FACE (SF): 25x60 = 1500 sfPLANTING AREA (SF): 180 320
TREE REMOVAL:
REGULATED TREE SPECIES FOR REMOVAL: 0SIGNIFICANT TREE SPECIES FOR REMOVAL: 0MITIGATION OF SIGNIFICANT: 0MITIGATION CREDITS FOR TREES SAVED: 0STD. MITIGATION (15 TREES PER DIST. AC): 15*0.5 ac = 7.5 TREES
Disturbed Acreage± (0.50 ac.)
4. No light poles are proposed. Only fully-cutoff fixtures are proposed at the entrance doors and garages.Building Inspections to review cutoff fixtures during review.
4. No ground signs are proposed. Signage to be permitted by Building Inspections.
EXISTING WELL TOBE ABANDONED
MEMORANDUM
To: New Hanover County Technical Review Committee
Date: March 18, 2025
Subject: Masonboro Commons Starbucks (SITECN-25-000063)
NCDOT Projects:
•N/A
WMPO 2045 MTP Projects:
•N/A
New Hanover County Projects:
•2024 Bicycle & Pedestrian Priorities Plan Amendment proposed project: Carolina Beach
Road South (US 421) paved multi-use path from Monkey Junction to Snows Cut Bridge.
TIA: A TIA for the proposed Masonboro Commons Starbucks was approved with conditions by
the WMPO on February 28th, 2025. All improvements outlined in the approved TIA are required.
Please reach out to Abby Lorenzo (Abigail.Lorenzo@wilmingtonnc.gov) and Caitlin Cerza
(Caitlin.Cerza@wilmingtonnc.gov) if any questions arise related to the TIA. The TIA approval
with conditions letter will be attached to these comments.
February 28, 2025 Jeff Hochanadel, PE, PTOE Timmons Group 5410 Trinity Road, Suite 102 Raleigh, NC 27607 RE: Approval with conditions for the Traffic Impact Analysis (TIA) associated with the proposed Masonboro Commons Starbucks development in New Hanover County, NC Dear Mr. Hochanadel, The WMPO has coordinated the review of the Masonboro Commons Starbucks TIA (sealed February 4, 2025)
by NCDOT and New Hanover County Staff. Based on the information provided and conversations held to date,
it is our understanding that the proposed development will be built in 2025 and will consist of:
Build Year 2025
• 2,500 SF Starbucks with Drive Thru (Local Data)
The following improvements are required for this development:
US 421 (Carolina Beach Road) at Site Access 1 (existing unsignalized right-in/right-out)
• No improvements are required.
US 421 (Carolina Beach Road) at SR 1524 (Golden Road)/Site Access 2 (existing signalized intersection)
• Extend the northbound left turn lane on US 421 (Carolina Beach Road) to provide 450 feet of full width
storage and appropriate deceleration and taper lengths.
If changes are made to the proposed site driveways and/or land uses, the current trip distribution may need to
be modified and would require a revised Traffic Impact Analysis to be submitted for review by the NCDOT,
WMPO, and New Hanover County, in which instance this approval would become null and void.
Approval with Conditions for the Masonboro Commons Starbucks Traffic Impact Analysis – New Hanover
Page 2 of 2
The applicant is required to obtain all applicable New Hanover County and NCDOT permits for access to the
road network. A copy of this TIA approval shall be included with any NCDOT driveway permit application. All
applicable NCDOT and New Hanover County technical standards and policies shall apply.
Please contact me at (910) 341-7890 with any questions regarding this approval.
Sincerely,
Abby Lorenzo, MPA Deputy Director Wilmington Urban Area MPO
Ec: Ben Hughes, PE, District Engineer, NCDOT
Jon Roan, Deputy District Engineer, NCDOT
Michael Bass, Assistant District Engineer, NCDOT
Frank Mike, Assistant District Engineer, NCDOT
Madi Lee, PE, Development Review Engineer, NCDOT
Stonewall Mathis, PE, Division Traffic Engineer, NCDOT
Bryce Cox, Senior Assistant Traffic Engineer, NCDOT
Nick Drees, Engineering Specialist, NCDOT
Robert Farrell, Development Review Supervisor, New Hanover County