Loading...
HomeMy WebLinkAbout1725-500693 - Site Plans_v1 (1)St . S t a n i s l a u s C h u r c h 48 4 9 C a s t l e H a y n e R d Ca s t l e H a y n e , N o r t h C a r o l i n a Sheet Title: Sheet No: Revisions: Date: Project no: Seals: Corp. NC license: F-1320 1725-500693 04.04.2025 Y: \ N o r t h C a r o l i n a \ 1 7 X X - 5 0 S \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 _ M L A _ S t a n i s l a u s E x p \ E n g _ D o c s \ D r a w i n g s \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 - C D \ 1 7 2 5 - 5 0 0 6 9 3 - M A S T E R . d w g Al f r e d B e n e s c h & C o m p a n y 20 1 8 E a s t w o o d R d , S u i t e 1 1 1 W i l m i n g t o n , N C 2 8 4 0 3 ww w . b e n e s c h . c o m P 9 1 0 . 3 4 4 . 0 1 4 3 Owner/Applicant Project Team Vicinity Map ST. STANISLAUS CHURCH 4849 CASTLE HAYNE ROAD, CASTLE HAYNE, NC 28429 FINAL DESIGN - NOT FOR CONSTRUCTION Alfred Benesch & Company 2018 Eastwood Road, Suite 111 Wilmington, NC 28403 www.benesch.com P 910.500.7081 Corp. NC License: F-1320 SAINT STANISLAUS CATHOLIC PARISH OF CASTLE HAYNE 4849 CASTLE HAYNE ROAD CASTLE HAYNE, NC 28429 Project Team Landscape Architect & Civil Engineer Vicinity Map Site Overview Map (1''=200') Sheet #Description Rev #Date Seal Date C001 COVER SHEET 1 C002 GENERAL NOTES & LEGEND 1 C100 EXISTING CONDITIONS AND DEMOLITION PLAN 1 C200 OVERALL SITE PLAN 1 C201 SITE PLAN 1 C300 1 C301 GRADING PLAN 1 C302 EROSION CONTROL PLAN 1 C500 POST CONSTRUCTION DRAINAGE AREAS 1 C501 EROSION CONTROL DETAILS 1 C502 EROSION CONTROL DETAILS 1 C503 SITE DETAILS 1 C504 1 C505 WET POND 01 DETAILS 1 C506 WET POND 01 DETAILS 1 Index of Drawings COVER C001 Architect LOCATION MAP NOT TO SCALE U S - 1 1 7 N C O L L E G E R D NC - 1 3 3 C A S T L E H A Y N E R D MARA T H O N A V E PAR M E L E R D MARK LOUDERMILK ARCHITECTURE 1409 MEDICAL CENTER DRIVE WILMINGTON, NC 28401 EROSION CONTROL DETAILS SITE DETAILS C600 LANDSCAPE PLAN 1 St . S t a n i s l a u s C h u r c h 48 4 9 C a s t l e H a y n e R d Ca s t l e H a y n e , N o r t h C a r o l i n a Sheet Title: Sheet No: Revisions: Date: Project no: Seals: Corp. NC license: F-1320 1725-500693 04.04.2025 Y: \ N o r t h C a r o l i n a \ 1 7 X X - 5 0 S \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 _ M L A _ S t a n i s l a u s E x p \ E n g _ D o c s \ D r a w i n g s \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 - C D \ 1 7 2 5 - 5 0 0 6 9 3 - M A S T E R . d w g Al f r e d B e n e s c h & C o m p a n y 20 1 8 E a s t w o o d R d , S u i t e 1 1 1 W i l m i n g t o n , N C 2 8 4 0 3 ww w . b e n e s c h . c o m P 9 1 0 . 3 4 4 . 0 1 4 3 GENERAL NOTES & LEGEND C002 EXISTING LEGEND EXISTING FIRE HYDRANT R/W EXISTING IRON PINEI EXISTING UTILITY POLE DYH CENTERLINECL EXISTING CURB AND GUTTER # OF PARKING SPACES ACCESSIBLE SPACE RIGHT-OF-WAY EXISTING LIGHT POLE EXISTING IRON PIN EXISTING SIGN EXISTING UTILITY POLE ACCESSIBLE RAMP PROPERTY LINE EXISTING FENCEXXX EXISTING EASEMENTE EXISTING ASPHALT PAVEMENT EXISTING OVERHEAD UTILITY LINEOH/U EXISTING UNDERGROUND ELECTRIC LINE EXISTING CONTOUR LINE EXISTING GAS LINE EXISTING WATER LINE EXISTING SANITARY SEWER LINE EXISTING UNDERGROUND TELEPHONE LINE EXISTING FIBER OPTIC LINE EXISTING STORM DRAINAGE PIPE EXISTING TREE TO REMAIN EXISTING STORM MANHOLE EXISTING SEWER MANHOLE EXISTING WATER METER EXISTING WATER VALVE FES 1 EXISTING DRAINAGE STRUCTURE EXISTING SPOT ELEVATION+XXX.X EXISTING TREE LINE EXISTING GAS METER EXISTING GAS VALVE PROPOSED FIRE HYDRANT PROPOSED GAS LINE PROPOSED WATER LINE PROPOSED SANITARY SEWER LINE PROPOSED WATER VALVE PROPOSED CHECK VALVE PROPOSED POST INDICATOR VALVE PROPOSED FIRE DEPT. CONNECTION PROPOSED LEGEND PROPOSED SIGN PROPOSED BOLLARD PROPOSED CURB AND GUTTER PROPOSED FLUSH CURB AND GUTTER PROPOSED FENCE PROPOSED HEAVY DUTY ASPHALT PAVEMENT PROPOSED VEHICULAR CONCRETE PAVEMENT PROPOSED STANDARD DUTY ASPHALT PAVEMENT PROPOSED CONTOUR LINE PROPOSED FLARED END SECTION MH 1 PROPOSED STORM MANHOLE PROPOSED STORM DRAINAGE PIPE PROPOSED ROOF DRAIN PIPE PROPOSED DRAINAGE STRUCTUREDI 1 PROPOSED SPOT ELEVATION PROPOSED WATER METER PROPOSED BACKFLOW PREVENTER PROPOSED SEWER MANHOLE SSMH 1 TEMPORARY TREE PROTECTION BARRICADE TEMPORARY SILT FENCE LIMITS OF GRADING/CONSTRUCTION LINED GRASS SWALE GRASS SWALE TEMPORARY DIVERSION SWALE PROPOSED CLEANOUT PROPOSED DRAINAGE STRUCTURE DI 1 EXISTING DOWNSPOUT EXISTING CLEANOUT TEMPORARY INLET PROTECTION TEMPORARY ROCK CHECK DAM TEMPORARY FILTER BERM BASIN TEMPORARY GRAVEL ENTRANCE OUTLET PROTECTION TEMPORARY SILT SACK PROPOSED CONCRETE SIDEWALK GENERAL SITE NOTES: 1.DIMENSIONS AND COORDINATE POINTS ARE TO FACE OF CURB, EDGE OF PAVEMENT, OR CORNER OF BUILDING UNLESS OTHERWISE NOTED. 2.EXISTING CONDITION SHOWN ARE BASED ON INFORMATION PROVIDED BY OTHERS. SEE SHEET C100 FOR ADDITIONAL INFORMATION. 3.ALL IMPROVEMENTS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL STANDARDS. 4.ANY DISCREPANCIES FOUND IN THE FIELD SHALL BE CALLED TO THE ATTENTION OF THE OWNER OR ENGINEER PRIOR TO PROCEEDING WITH WORK. 5.PRIOR TO BEGINNING CONSTRUCTION, UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS (BOTH SITE AND BUILDING RELATED) INCLUDING BUT NOT LIMITED TO REGULATORY FEES, LICENSES, AND INSPECTIONS NECESSARY FOR PROPER EXECUTION AND COMPLETION OF THE WORK. 6.THE GENERAL CONTRACTOR SHALL CONTACT ALL OWNERS OF EASEMENTS, UTILITIES, AND RIGHT-OF-WAYS, PUBLIC AND PRIVATE, PRIOR TO WORKING IN THESE AREAS. 7.GENERAL CONTRACTOR SHALL MAINTAIN THE SITE IN A MANNER SO THAT WORKMEN AND THE PUBLIC SHALL BE PROTECTED FROM INJURY. 8.USE CAUTION WHEN REPRODUCING COPIES OF THE CONSTRUCTION DRAWINGS. COPIES ARE SUBJECT TO DISTORTION AND INACCURACY IN THE SCALE OF DRAWINGS. VERIFY ANY DISCREPANCIES WITH THE DESIGNER OF RECORD. 9.ALL SIGNS, PAVEMENT MARKINGS, AND OTHER TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD), LATEST EDITION AS AMENDED. 10.ALL PAVEMENT MARKINGS SHALL BE FOUR (4) INCHES WIDE UNLESS INDICATED OTHERWISE ON THE DRAWINGS. 11.CONTRACTOR SHALL FURNISH AND INSTALL ALL PAVEMENT MARKINGS AS SHOWN ON THE PLANS. 12.CONTRACTOR SHALL SAW-CUT EXISTING ASPHALT PAVEMENT AREAS TO TIE IN SMOOTHLY TO PROPOSED PAVEMENT AT DRIVEWAY ENTRANCES. 13.REFER TO ARCHITECTURAL PLANS FOR ACTUAL BUILDING DIMENSIONS. 14.THE ENGINEER WILL PROVIDE THE CONTRACTOR WITH AN ELECTRONIC FILE OF THESE DRAWINGS UPON REQUEST. 15.CONTACT THE UTILITY COMPANY TO RELOCATE ANY UTILITIES REQUIRED FROM COMPLETION OF THE PROJECT. ALL EXISTING FACILITIES WHICH CONFLICT WITH THE IMPROVEMENTS UNDER THE SCOPE OF THIS PROJECT MUST BE RELOCATED AT THE EXPENSE OF THE CONTRACTOR. 16.ALL SIGNAGE MUST CONFORM TO NCDOT AND NEW HANOVER COUNTY STANDARDS. 17.LIGHTING PLAN BY OTHERS. ALL LIGHTING MUST BE IN ACCORDANCE WITH NEW HANOVER COUNTY UDO. 18.STOP BEFORE YOU DIG. CALL 811. IT'S THE LAW. GRADING AND DRAINAGE NOTES: 1.CONTRACTOR SHALL PERFORM HIS OWN ESTIMATES AND SHALL PROVIDE ALL EARTHWORK NECESSARY TO ACHIEVE THE DESIGN GRADE, INCLUDING ANY OFFSITE BORROW OR SPOILS REQUIRED. 2.CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE IN ALL GRADED AREAS, INCLUDING PAVING, LAWN AND LANDSCAPE AREAS. 3.THE CONTRACTOR SHALL IMMEDIATELY REPORT TO OWNER ANY DISCREPANCIES FOUND BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS AND SHALL WAIT FOR INSTRUCTION PRIOR TO PROCEEDING. 4.CONTRACTOR SHALL VERIFY LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO BEGINNING WORK, BOTH PUBLIC AND PRIVATE. CONTRACTOR IS FULLY RESPONSIBLE FOR ALL UNDERGROUND UTILITIES AND SHALL REPAIR ANY DAMAGE AS A RESULT OF THIS CONTRACT. 5.CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE. 6.THE PROPOSED CONTOURS AND SPOT ELEVATIONS SHOWN IN DRIVES, PARKING LOTS AND SIDEWALKS ARE FINISHED ELEVATIONS INCLUDING ASPHALT. REFER TO PAVEMENT CROSS SECTION DATA TO ESTABLISH CORRECT SUBBASE OR AGGREGATE BASE COURSE ELEVATIONS TO BE COMPLETED UNDER THIS CONTRACT. 7.PIPE LENGTHS SHOWN ARE THE ENGINEER'S ESTIMATE USED TO COMPUTE PIPE SLOPES AND INVERTS AND SHALL NOT BE CONSTRUED BY THE CONTRACTOR TO REPRESENT THE ACTUAL QUANTITY OF PIPE REQUIRED. 8.STORM STRUCTURE RIM ELEVATIONS LISTED FOR CURB INLETS AREA THE GRATE ELEVATIONS (FRONT OF GUTTER) UNLESS OTHERWISE INDICATED. 9.CROSS SLOPE OF SIDEWALKS SHALL BE 1/4"/FT. (MAX). 10.SLOPES SHALL BE GRADED NO STEEPER THAN 2:1 11.EXPOSED TREE ROOTS MUST BE CLEANLY CUT WITH A SHARP PRUNING TOOL; BACKFILL ASAP TO MINIMIZE EXPOSURE TO THE AIR. 12.IN ORDER TO ENSURE ADEQUATE DRAINAGE FLOW LINES IN GUTTERS SHALL BE 0.50% MINIMUM. 13.SPOT ELEVATIONS ON CURB & GUTTER ARE THE FLOW LINE ELEVATIONS UNLESS OTHERWISE INDICATED. 14.ALL UTILITY LINES (ELEC, WATER, SANITARY, STORM) REQUIRE THE USE OF TRACER WIRER/TAPE INSTALLED ABOVE THE PIPE AT 30" BELOW FINISH GRADE AND WARNING TAPE LOCATED AT 12" ABOVE THE PIPE. 18.THE AMENDED 2018 NCPC SECTION 306.2.4 TRACER WIRE, FOR PLASTIC SEWER (STORM AND SANITARY) PIPING, AN INSULATED COPPER TRACER WIRE OR OTHER APPROVED CONDUCTOR SHALL BE INSTALLED ADJACENT TO AND OVER THE FULL LENGTH OF THE PIPING. ACCESS SHALL BE PROVIDED TO THE TRACER WIRE OR THE TRACER WIRE SHALL TERMINATE AT THE CLEANOUT BETWEEN THE BUILDING DRAIN AND BUILDING SEWER. THE TRACER WIRE SIZE SHALL BE NOT LESS THAN 14 AWG AND THE INSULATION TYPE SHALL BE LISTED FOR DIRECT BURIAL. UTILITY NOTES: 1.ALL UTILITY CONSTRUCTION (PRIVATE AND PUBLIC) SHALL BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODE REQUIREMENTS. 2.ALL UTILITIES MUST CONFIRM TO AQUA NORTH CAROLINA STANDARDS AND SPECIFICATIONS FOR MATERIALS AND INSTALLATION. 3.CONTRACTOR IS REQUIRED TO SCHEDULE ANY REQUIRED PRE-CONSTRUCTION MEETINGS WITH UTILITY PROVIDERS PRIOR TO INSTALLATION OF ANY UTILITIES. 4.THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES (STORM DRAINAGE, ELECTRIC, GAS, TELEPHONE, ETC.) PRIOR TO CONSTRUCTION. INFORMATION SHOWN ON THIS PLAN IS FOR REFERENCE ONLY AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR. 5.THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY IF ANY DISCREPANCIES BETWEEN THE CONSTRUCTION PLANS AND ACTUAL FIELD CONDITIONS ARE FOUND. 6.MINIMUM COVER FOR ALL SANITARY SEWER LINES SHALL BE 3'-0". DUCTILE IRON PIPE SHALL BE SUBSTITUTED WHEN MINIMUM COVER CAN NOT BE MAINTAINED. 7.THE STANDARD DEPTH OF COVER FOR WATER LINES SHALL BE 3'-0" MIN. EXCEPT AT VALVE OR HYDRANT LOCATIONS, OR OTHER SPECIAL CONDITIONS. 8.THE CONNECTION TO EXISTING WATER MAINS SHALL BE PERFORMED ONLY AFTER ALL PRESSURE TESTING AND CHLORINATION ARE SUCCESSFULLY COMPLETED AND THE LOCAL REVIEW AUTHORITY HAS APPROVED THE CONNECTION. THE CONTRACTOR SHALL AVOID DISRUPTION OF EXISTING SERVICE. 9.REFER TO PLUMBING DRAWING SERIES FOR THE LOCATION OF WATER AND SANITARY SEWER SERVICE CONNECTIONS AT THE BUILDING. 10.UNLESS OTHERWISE NOTED, THE PHYSICAL CONNECTION BETWEEN THE SITE UTILITY LINES AND THE PIPE INSTALLED BY THE PLUMBING CONTRACTOR SHALL BE MADE BY THE SITE UTILITY CONTRACTOR. 11.PIPE LENGTHS SHOWN ON PLAN ARE THE ENGINEER'S ESTIMATE USED TO COMPUTE PIPE SLOPES AND INVERTS AND SHALL NOT BE CONSTRUED BY THE CONTRACTOR TO REPRESENT THE ACTUAL QUANTITY OF PIPE REQUIRED. 12.IF WATER LINE CROSSES OVER SANITARY SEWER WITH LESS THAN 18" INCHES VERTICAL CLEARANCE BOTH PIPES SHALL BE DUCTILE IRON 10' EACH SIDE. IF WATER CROSSES UNDER THE SEWER REGARDLESS OF CLEARANCE, BOTH PIPES SHALL BE DUCTILE IRON 10' EACH SIDE. IF WATER LINE RUNS PARALLEL TO SEWER LINE WITH LESS THAN 18" VERTICAL CLEARANCE AND LESS THAN 10' SIDE CLEARANCE BOTH PIPES SHALL BE DUCTILE IRON. 13.ALL CONSTRUCTION SHALL ADHERE TO THE NEW HANOVER COUNTY AND NCDEQ STANDARDS. IN THE EVENT OF CONFLICTING REQUIREMENTS, THE MOST STRINGENT SHALL APPLY. 14.IF REQUIRED BY NUMBER 10 ABOVE, REPLACE EXISTING SEWER WITH DUCTILE IRON PIPE, CLASS 350 WORKING PRESSURE WITH GASKETED JOINTS, 10' EACH SIDE OF WATER MAIN. 15.THERE SHALL BE NO TAPS, PIPING BRANCHES, UNAPPROVED BYPASS PIPING, HYDRANTS, FIRE DEPT. CONNECTION POINTS, OR OTHER WATER-USING APPURTENANCES CONNECTED TO THE SUPPLY LINE BETWEEN ANY WATER METER AND ITS REQUIRED BACKFLOW PREVENTER. 16.EACH REQUIRED BACKFLOW PREVENTION ASSEMBLY IS REQUIRED TO BE TESTED BY THE PROVIDER AND APPROVED PRIOR TO PLACING THE WATER SYSTEM IN SERVICE. 17.CONTRACTOR IS REQUIRED TO REQUEST ANY REQUIRED UTILITY INSPECTION AND PROVIDE DOCUMENTATION OF PASSING INSPECTION TO THE ENGINEER PRIOR TO USE. 18.UTILITY PROVIDER MUST BE ONSITE TO WITNESS THE METER RELOCATION AND ALL METER AND NEW TAP INSTALLATIONS. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE WORK WITH UTILITY PROVIDER. 19.UTILITY PROVIDER MUST BE ONSITE TO WITNESS SEWER CONNECTIONS. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE WORK WITH UTILITY PROVIDER . STORMWATER AND EROSION CONTROL PERMITTING NOTES: 1.AN NCDEQ STORMWATER PERMIT IS REQUIRED FOR THE PROJECT. NO IMPERVIOUS CAN BE PLACED ONSITE PRIOR TO APPROVAL OF AN NCDEQ STORMWATER PERMIT. 2.AN NCDEQ SEDIMENT AND EROSION CONTROL PERMIT WILL BE REQUIRED. NO DISTURBANCE OF GREATER THAN 1 ACRE CAN OCCUR PRIOR TO APPROVAL. 3.THERE ARE NO KNOWN SURFACE WATERS OR WETLANDS LOCATED WITHIN THE PROJECT AREA. 40' 30' St . S t a n i s l a u s C h u r c h 48 4 9 C a s t l e H a y n e R d Ca s t l e H a y n e , N o r t h C a r o l i n a Sheet Title: Sheet No: Revisions: Date: Project no: Seals: Corp. NC license: F-1320 1725-500693 04.04.2025 Y: \ N o r t h C a r o l i n a \ 1 7 X X - 5 0 S \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 _ M L A _ S t a n i s l a u s E x p \ E n g _ D o c s \ D r a w i n g s \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 - C D \ 1 7 2 5 - 5 0 0 6 9 3 - M A S T E R . d w g Al f r e d B e n e s c h & C o m p a n y 20 1 8 E a s t w o o d R d , S u i t e 1 1 1 W i l m i n g t o n , N C 2 8 4 0 3 ww w . b e n e s c h . c o m P 9 1 0 . 3 4 4 . 0 1 4 3 40 0 20 40 80 SCALE: 1"=40' NORTH Know what's below. before you dig.Call R EXISTING CONDITIONS AND DEMOLITION PLAN C100 CASTLE HAYNE ROAD (NC 133) M A R A T H O N A V E N U E ( S R 1 3 3 7 ) ZONING: RA USE: RESIDENCE ZONING: RA USE: RESIDENCE ZONING: RA USE: RESIDENCE ZONING: RA USE: RESIDENCE ZONING: RA USE: RESIDENCE REMOVE CONCRETE SIDEWALK (TYP) SAWCUT AND REMOVE ASPHALT REMOVE RCP PIPE TREE CLEARING AS REQUIRED FOR POND GRADING (TYP) GENERAL NOTES: 1.SEE SHEET C002 FOR GENERAL NOTES AND LEGEND. 2.SEE SHEET C200 FOR OVERALL SITE PLAN. GENERAL SITE NOTES: 1.SURVEY INFO PROVIDED BY OWNER. ELEVATIONS AND DISTANCES BASED ON NAD83 AND NAVD88. 2.ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES IN U.S. FOOT UNLESS OTHERWISE NOTED. 3.PROPERTY MAY BE SUBJECT TO ANY/ALL EASEMENTS AND RESTRICTIONS OF RECORD. THIS SURVEY IS A CORRECT REPRESENTATION OF THE LAND PLATTED AND OR DEEDED AND HAS BEEN PREPARED WITHOUT THE BENEFIT OF A FULL TITLE REPORT. A NORTH CAROLINA LICENSED ATTORNEY-AT-LAW SHOULD BE CONSULTED REGARDING CORRECT OWNERSHIP, WIDTH AND LOCATION OF EASEMENTS, AND OTHER TITLE EXAMINATION. 4.NCGS MONUMENT MARATHON PID: EA2876 IS WITHIN 2,000 FEET OF PROPERTY. 5.FLOOD NOTE: THIS PROPERTY IS LOCATED IN ZONE X ACCORDING TO FEMA FLOOD MAP: | NEW HANOVER COUNTY-CID: 372032 | PANEL: 2100 & 3100 | SUFFIX: K | EFFECTIVE DATE: 8/28/2018 | 40' 30' X X X X X X X X X X X X X X X X X X X X X X X X X GENERAL NOTES: 1.SEE SHEET C002 FOR GENERAL NOTES AND LEGEND. 2.SEE SHEET C100 FOR EXISTING CONDITIONS AND DEMOLITION PLAN. 3.SEE SHEET C201 FOR ENLARGED SITE PLAN. St . S t a n i s l a u s C h u r c h 48 4 9 C a s t l e H a y n e R d Ca s t l e H a y n e , N o r t h C a r o l i n a Sheet Title: Sheet No: Revisions: Date: Project no: Seals: Corp. NC license: F-1320 1725-500693 04.04.2025 Y: \ N o r t h C a r o l i n a \ 1 7 X X - 5 0 S \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 _ M L A _ S t a n i s l a u s E x p \ E n g _ D o c s \ D r a w i n g s \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 - C D \ 1 7 2 5 - 5 0 0 6 9 3 - M A S T E R . d w g Al f r e d B e n e s c h & C o m p a n y 20 1 8 E a s t w o o d R d , S u i t e 1 1 1 W i l m i n g t o n , N C 2 8 4 0 3 ww w . b e n e s c h . c o m P 9 1 0 . 3 4 4 . 0 1 4 3 40 0 20 40 80 SCALE: 1"=40' NORTH Know what's below. before you dig.Call R OVERALL SITE PLAN C200 CASTLE HAYNE ROAD (NC 133) M A R A T H O N A V E N U E ( S R 1 3 3 7 ) PR O P O S E D F F E C BU I L D I N G SITE DATA: 1.PARCEL ID: R01700-003-003-000 2.PROJECT ADDRESS: 4849 CASTLE HAYNE ROAD CASTLE HAYNE, NC 28429 3.PROPERTY DEED AND PLAT DB: 6580 PG: 1906 MB: 61 PG: 56 4.SAINT STANISLAUS CATHOLIC PARISH OF CASTLE HAYNE 4849 CASTLE HAYNE ROAD CASTLE HAYNE, NC 28429 5.LAND USE: CURRENT LAND USE - CHURCH PROPOSED LAND USE -CHURCH 6.ZONING - RA (RURAL AGRICULTURE) 7.PARCEL ACREAGE: 41.98 AC 8.BUILDING SETBACKS: FRONT: 40 FEET SIDE: 30 FEET (STREET), 20 FEET (INTERIOR) REAR: 30 FEET 9.PARKING SPACES: EXISTING TO REMAIN:110 SPACES PROPOSED:38 SPACES TOTAL PARKING:148 SPACES (10 ADA ACCESSIBLE, 138 STANDARD) ZONING: RA USE: RESIDENCE ZONING: RA USE: RESIDENCE ZONING: RA USE: RESIDENCE ZONING: RA USE: RESIDENCE ZONING: RA USE: RESIDENCE 40' 30' X X X X X X St . S t a n i s l a u s C h u r c h 48 4 9 C a s t l e H a y n e R d Ca s t l e H a y n e , N o r t h C a r o l i n a Sheet Title: Sheet No: Revisions: Date: Project no: Seals: Corp. NC license: F-1320 1725-500693 04.04.2025 Y: \ N o r t h C a r o l i n a \ 1 7 X X - 5 0 S \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 _ M L A _ S t a n i s l a u s E x p \ E n g _ D o c s \ D r a w i n g s \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 - C D \ 1 7 2 5 - 5 0 0 6 9 3 - M A S T E R . d w g Al f r e d B e n e s c h & C o m p a n y 20 1 8 E a s t w o o d R d , S u i t e 1 1 1 W i l m i n g t o n , N C 2 8 4 0 3 ww w . b e n e s c h . c o m P 9 1 0 . 3 4 4 . 0 1 4 3 20 0 10 20 40 SCALE: 1"=20' NORTH Know what's below. before you dig.Call R SITE PLAN C201 STANDARD DUTY ASPHALT PAVING (TYP) 24 ' 9' (TYP)18 ' (T Y P ) M A R A T H O N A V E N U E ( S R 1 3 3 7 ) CONCRETE SIDEWALK (TYP) CONCRETE SIDEWALK AND CROSSWALK PROPOSED DROP INLET 100 LF OF 18" CLASS V RCP @ 0.25% DI 102 RIM 19.95 IE. ± 16.67 PROPOSED 24" FES WITH RIP-RAP IE. 14.5 POND SECURITY FENCE (6' HT CHAIN LINK) STORMWATER CONTROL MEASURE (SCM) (SEE DETAIL SHEETS) DUMPSTER PAD W/ ENCLOSURE 12' 12 ' 4' PROPOSED FFEC BUILDING FFE: 25.0 1" WATER SERVICE (PVC OR CTS) MIN. 36" COVER AT ALL LOCATIONS. CONTRACTOR TO COORDINATE FINAL CONNECTION LOCATION TO SUPPLY (SITE SERVED BY WELL) 4" SANITARY SEWER SERVICE (SCH 40) (TO SEPTIC TANK) (MIN. 1.0% SLOPE)CONNECT TO BUILDING PLUMBING. COORDINATE FINAL LOCATION AND DEPTH WITH PLUMBING PLANS. (TYP) SSCO RIM 24.5' IE 22.0' CONNECT TO EXISTING LINE TO SEPTIC TANK SEWER CONNECTION PENDING CONFIRMATION OF CAPACITY FROM NHCEH DI 103 RIM 19.98 IE. 16.92 88 LF OF 24" CLASS V RCP @ 2.46% GENERAL NOTES: 1.SEE SHEET C002 FOR GENERAL NOTES AND LEGEND. 2.SEE SHEET C100 FOR EXISTING CONDITIONS AND DEMOLITION PLAN. 3.SEE SHEET C200 FOR OVERALL SITE PLAN. SITE DATA: 1.PARCEL ID: R01700-003-003-000 2.PROJECT ADDRESS: 4849 CASTLE HAYNE ROAD CASTLE HAYNE, NC 28429 3.PROPERTY DEED AND PLAT DB: 6580 PG: 1906 MB: 61 PG: 56 4.SAINT STANISLAUS CATHOLIC PARISH OF CASTLE HAYNE 4849 CASTLE HAYNE ROAD CASTLE HAYNE, NC 28429 5.LAND USE: CURRENT LAND USE - CHURCH PROPOSED LAND USE -CHURCH 6.ZONING - RA (RURAL AGRICULTURE) 7.PARCEL ACREAGE: 41.98 AC 8.BUILDING SETBACKS: FRONT: 40 FEET SIDE: 30 FEET (STREET), 20 FEET (INTERIOR) REAR: 30 FEET 9.PARKING SPACES: EXISTING TO REMAIN:110 SPACES PROPOSED:38 SPACES TOTAL PARKING:148 SPACES (10 ADA ACCESSIBLE, 138 STANDARD) UTILITY NOTES: 1.EXISTING SEPTIC SYSTEM EXPANSION IS NOT REQUIRED. THE NEW BUILDING SHALL BE USED AS ANCILLARY TO EXISTING SANCTUARY AND WILL NOT INCREASE TOTAL NUMBER OF PARISHIONERS CURRENTLY USING THE FACILITY. THE NEW BUILDING MAY NOT BE USED AS A DAYCARE OR K-12 SCHOOL. St . S t a n i s l a u s C h u r c h 48 4 9 C a s t l e H a y n e R d Ca s t l e H a y n e , N o r t h C a r o l i n a Sheet Title: Sheet No: Revisions: Date: Project no: Seals: Corp. NC license: F-1320 1725-500693 04.04.2025 Y: \ N o r t h C a r o l i n a \ 1 7 X X - 5 0 S \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 _ M L A _ S t a n i s l a u s E x p \ E n g _ D o c s \ D r a w i n g s \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 - C D \ 1 7 2 5 - 5 0 0 6 9 3 - M A S T E R . d w g Al f r e d B e n e s c h & C o m p a n y 20 1 8 E a s t w o o d R d , S u i t e 1 1 1 W i l m i n g t o n , N C 2 8 4 0 3 ww w . b e n e s c h . c o m P 9 1 0 . 3 4 4 . 0 1 4 3 SITE DETAILS C503 1 Asphalt Pavement Detail N.T.S. FINISH GRADE PROVIDE COMPACTED BEVELED EDGE Standard Duty Paving Section Heavy Duty Paving Section CARRY BASE COURSE 12" BEYOND SURFACE COURSE 12" CURB AND GUTTER AT LOCATIONS WITHOUT (2 LIFTS), SEE GEOTECH REPORT 3.0" S.9.5B SUPERPAVE ASPHALT SURFACE COURSE 1 2 NOTES COMPACTED ABC 6" (98% STD. PROCTOR) COMPACTED SUBGRADE 98% STD. PROCTOR. COMPACT UPPER 24" MINIMUM OF 100% DENSITY (ASTM D-698). SEE SPECIFICATIONS CARRY ABC COURSE BEYOND BACK OF CURB FINISH GRADE 1 2 CARRY BASE COURSE 12" BEYOND SURFACE COURSE 12" CURB AND GUTTER AT LOCATIONS WITHOUT PROVIDE COMPACTED BEVELED EDGE 2" - S9.5B SUPERPAVE ASPHALT 6" 2" (2 LIFTS, MIN) COMPACTED SUBGRADE 95% STD. PROCTOR. COMPACT UPPER 24" MINIMUM OF 100% DENSITY (ASTM D-698). SEE SPECIFICATIONS 6" COMPACTED ABC (98% STD. PROCTOR) CURB AND GUTTER, SEE DETAIL 6" 6" 18" 2 Concrete Paving - Heavy Duty N.T.S. 2' LONG. GREASE STEEL 6" 8" ABC 6" COMPACTED COMPACTED CONSTRUCTION JOINT (AS REQUIRED) INSTALL 1" DIA. SMOOTH STEEL DOWELS 18" O.C.- AND SEAL AS NOTED. 28 DAYS MEDIUM BROOM FINISH 4,000 PSI CONCRETE @ SCORE JOINT MIN. 1/8" X 1-1/2" SAW CUT AS SHOWN NEW POUR IS CONTIGUOUS TO ANY STRUCTURE, AND AT 25' O.C. MAX. EXPANSION JOINT. PLACE EXP. JOINT WHERE SHOWN ON PLAN AND WHERE SEALER AS SPECIFIED-1/2" THICK 1/16" BELOW FLUSH ON 1/2" THICK JOINT @ 30' O.C. WITH JOINT PROVIDE 1/2" BIT. EXPANSION SUBGRADE PROVIDE FIBERMESH REINFORCING. USE FIBERMESH 650 BY PROPEX. MIX AT 4LBS/CUBIC YARD. STEEL REINFORCING @ 24" O.C. MAX. BOTH WAYS, 2 1/2" (MIN). SEE DETAIL #10 SHEET 5.3.1 FOR MORE INFO. 12"12" 3/8" 3/ 8 " 3/8"MACHINE CUT 3/8"x3/8" CHAMFER; CAULK JOINT W/SONOLASTIC SL 2 POLYURETHANE SEALANT AS MANUFACTURED BY SONNEBORN. INSTALL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS 1"Øx18" GRADE 40 SMOOTH STEEL DOWEL @ 18" O.C., COATED WITH EPOXY PER ASTM M 284. GREASE FULL LENGTH. OMIT WHERE INDICATED ON PAVING PLAN. SEE PAVEMENT SECTION FOR ADDITION INFORMATION BACKER ROD CUT OFF ALL WIRES THAT CROSS JOINTS BEFORE PLACING CONCRETE. NOTE: 1.ALL TIE WIRES CROSSING THE JOINT SHALL BE REMOVED AFTER BASKETS ARE IN PLACE AND PRIOR TO POURING CONCRETE. 2.NO DOWELS ALLOWED WITHIN 12" OF A CROSS JOINT. CONTRACTION JOINT DETAIL 3 Concrete Sidewalk Detail N.T.S. HAND TROWEL SCORE JOINT- 1/4"X3/4" DEEP SEE SITE PLAN FOR SCORE JOINT SPACING PROVIDE 12" BIT. EXPANSION JOINT @ 30' O.C. WITH JOINT SEALER AS SPECIFIED-1/2" THICK, 1 16" BELOW FLUSH ON 1 2" THICK EXPANSION JOINT. PLACE EXP. JOINT WHERE SHOWN ON PLAN, WHERE NEW POUR IS CONTIGUOUS TO ANY STRUCTURE, AND AT 30' O.C. MAX. 3500 PSI FIBER- REINFORCED CONCRETE COMPACTED SUBGRADE 95% STD. PROCTOR ASTM D 698 MEDIUM BROOM FINISH PERPENDICULAR TO TRAFFIC FLOMIN. 1/4" X 3/4" TOOLED JOINT WITH RADIUS EDGES. 4" SIDEWALK CONTRACTOR TO BACKFILL ALL SIDEWALKS WITH SUITABLE SOIL WI D T H V A R I E S SE E S I T E P L A N MEDIUM BROOM FINISH PERPENDICULAR TO TRAFFIC FLOW 1.PAVEMENT RECOMMENDATIONS TO BE CONFIRMED BY GEOTECH. 2.PERFORM COMPACTION IN ACCORDANCE WITH SECTION 520 OF THE MOST RECENT VERSION OF THE NCDOT STANDARD SPECIFICATION FOR ROADWAYS AND STRUCTURES. NOTES: 1.PROVIDE CONTRACTION JOINTS SPACED EQUAL TO THE SIDEWALK WIDTH AND EXPANSION JOINT BETWEEN ALL TRANSITIONS TO CURBING AND BUIDLINGS, AND AT A MAXIMUM SPACING OF 50' O.C. 4 Accessible Parking/Signage/Striping Detail N.T.S. RESERVED PARKINGPARKING DISABLED PASSENGER LOADING ONLY CAB C C NOTES 1.RAMP AND WING SLOPES SHALL NOT BE STEEPER THAN 1:12. 2.GUTTER FLOW LINE AND PLAN PROFILE SHALL BE MAINTAINED THROUGH THE RAMP AREA. 3.IF ACCESSIBLE ROUTE IS A RAISED SIDEWALK AREA, THEN RAMPS ARE REQUIRED AT LOADING ZONE AREA. 4.COORDINATE CONSTRUCTION TO COMPLY WITH LOCAL AND FEDERAL ADA STANDARDS. 5.ALL 12"x18" ACCESSIBLE SIGNS (R7-8a AND R7-1) SHALL BE MOUNTED AT 7 FEET FROM GRADE TO BOTTOM EDGE OF SIGN FACE (MUTCD). MOUNTING HEIGHT CAN BE REDUCED TO 5 FEET IF PLACED IN AN AREA BETWEEN SIDEWALK AND BUILDING FACE IN WHICH PEDESTRIANS ARE NOT EXPECTED TO USE. 6.REFER TO MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, (MUTCD) U.S. DEPARTMENT OF TRANSPORTATION AND NORTH CAROLINA DEPARTMENT OF TRANSPORTATION SUPPLEMENT. 7.THE SURFACE OF THE RAMP SHALL BE FLUSH WITH THE FLOWLINE OF THE CURB AND GUTTER. 8.REFER TO PLAN SHEETS FOR ALL GRADING AND RAMP LOCATIONS/CONFIGURATIONS. 2% SLOPE 12" 12" 1"6"WIDTH VARIES, SEE PLAN 4" THICK CONCRETE WALK TAPERED CURBSEALED EXPANSION JOINT FINISH GRADE ASPHALT PAVEMENT A A 2% S L O P E 1:12 SLOPE TAPER CURB AND WALK DOWN TO GUTTER GRADE CURB AND GUTTER 4" WIDE WHITE PAINTED LINE 4" WIDE WHITE PAINTED STRIPES @45° ANGLE EQUAL SPACES, 5' O.C. 18 ' 8' 5', (8' WIDE FOR VAN ACCESSIBLE) 8' 6'6' FLUSH CURB WIDTH VARIES, SEE SITE PLAN SIDEWALK ACCESSIBLE PARKING SIGN CENTERED IN SPACE, (TYP.) R7-8e 12"x6" R7-8D 12"x9" MUTCD R7-8a 12"x18" MUTCD R7-8a 12"x18" R7-8D 12"x9" MUTCD R7-1 12"x18" MAXIMUM PENALTY $ 250 MAXIMUM PENALTY $ 250 RESERVED PARKING VAN ACCESSIBLE A B C ACCESSIBLE ROUTE (SEE NOTE #3) SIGNAGE ONE OUT OF EVERY SIX (6) ACCESSIBLE SPACE, BUT NOT LESS THAN ONE, IS REQUIRED TO BE VAN ACCESSIBLE 8'8'5'8'8'8' VAN ACCESSIBLE SPACE 1:12 SLOPE MAXIMUM PENALTY $ 250 RESERVED PARKING VAN ACCESSIBLE FINISH GRADE 2' - 6 " MI N . R7-8e 6"x12" SIGN AT VAN ACCESSIBLE SPACES ONLY R7-8 OR R7-8a 12"x18" SIGN R7-8D GS 20-37.6 9"x12" SIGN 2 LB/FT. GALV. U CHANNEL DRIVEN 2'-6" MIN. INTO COMPACTED EARTH SE E N O T E # 5 WHITE SYMBOL BLUE WHITE BACKGROUND GREEN 5 Painted Crosswalk N.T.S. CROSSWALK PLAN FLUSH CURB, SEE DETAIL CURB AND GUTTER 12" WIDE x 6'-0" LONG WHITE PAINTED BARS 6'-0" 2' - 6 " ± TY P . VEHICULAR PAVING CURB AND GUTTER FLUSH CURB, SEE DETAIL 1. CROSSWALK SHALL MEET 'MANUAL OF TRAFFIC CONTROL DEVISES' MIN REQ. NOTES St . S t a n i s l a u s C h u r c h 48 4 9 C a s t l e H a y n e R d Ca s t l e H a y n e , N o r t h C a r o l i n a Sheet Title: Sheet No: Revisions: Date: Project no: Seals: Corp. NC license: F-1320 1725-500693 04.04.2025 Y: \ N o r t h C a r o l i n a \ 1 7 X X - 5 0 S \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 _ M L A _ S t a n i s l a u s E x p \ E n g _ D o c s \ D r a w i n g s \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 - C D \ 1 7 2 5 - 5 0 0 6 9 3 - M A S T E R . d w g Al f r e d B e n e s c h & C o m p a n y 20 1 8 E a s t w o o d R d , S u i t e 1 1 1 W i l m i n g t o n , N C 2 8 4 0 3 ww w . b e n e s c h . c o m P 9 1 0 . 3 4 4 . 0 1 4 3 SITE DETAILS C504 3 Cleanout N.T.S. CLEANOUT IN UNPAVED AREAS CLEANOUT IN PAVED AREAS PVC BODY WITH BRONZE PLUGCLEANOUT TO BE FLUSH WITH GRADE ALL PIPE BENDS AND CONNECTIONS SHALL BE 45° MAX. NOTE: ENGRAVE "SS" IN SANITARY SEWER PLUG AND ENGRAVE "SD" IN STORM DRAIN PLUG. CAST IRON BODY WITH BRONZE PLUG 12"X12"X8" CONCRETE PAD FLUSH TO GRADE (3000 PSI MIN.) CLEANOUT TO BE FLUSH WITH GRADE 4" PVC RISER ALL PIPE BENDS AND CONNECTIONS SHALL BE 45° MAX. 4" PVC RISER SEE DRAINAGE OR UTILITY PLAN FOR PIPE SIZE AND MATERIAL SEE DRAINAGE OR UTILITY PLAN FOR PIPE SIZE AND MATERIAL NOTES: 1.STUB-UP INSTALLED BY UTILITY CONTRACTOR TO ALLOW LOCATION OF LATERAL BY PLUMBER. 2.SERVICE LINE BY PLUMBER MUST CONNECT TO TAPPED END OF CLEAN OUT WYE. 3.STUB-UP TO BE CUT-OFF & CLEAN-OUT PLUG INSTALLED FLUSH WITH GRADE AFTER LANDSCAPING. 4.SAN. SWR. LATERAL PIPE TO BE ASTM D3034-SDR 35 PVC PIPE. 1 Utility Trench N.T.S. C L NOTES: 1.BACKFILL TO 95% OF MAXIMUM DENSITY WHERE EXCAVATIONS CUT THROUGH PAVEMENTS, CURBS, DRIVEWAYS AND SIDEWALKS, AND UNDER OR ADJACENT TO STRUCTURES. 2.STONE TO BE SIZE 1 2" TO 1-1 2", WELL TAMPED. 3.STONE IS REQUIRED TO 6" BELOW PIPE WHERE WET CONDITIONS OR ROCK IS ENCOUNTERED, ONLY AS DIRECTED. 4.HAND SHAPE TRENCH BOTTOM FOR LOWER QUADRANT OF PIPE AND BELLS. 5.PROVIDE MINIMUM 3'-0" COVER OVER PIPE. 6.STONE TO 12 PIPE DIA. NOT REQUIRED FOR C-900 PVC OR DUCTILE IRON PIPE. BOTTOM OF EXCAVATION (SEE NOTE 3) STONE PIPE LINE TRENCH WIDTH 18 " 1 2 PIPE DIA. (SEE NOTE 6) SE L E C T B A C K F I L L CO M P A C T E D T O 9 5 % OF M A X I M U M D E N S I T Y BA C K F I L L C O M P A C T E D TO 9 5 % O F M A X I M U M DE N S I T Y E X C E P T AS N O T E D 8" MIN. 8" MIN. 2 Concrete Wheelstop Detail N.T.S. 7" SEE PLAN FOR PAVEMENT TYPE 12" RECESS. GROUT RECESS FLUSH WITH TOP OF WHEELSTOP 4"1 1 2" CONCRETE WHEELSTOP ±2 ' - 6 " 1'- 6 " 6'CONCRETE APRON WHEELSTOP CENTERED IN PARKING SPACE (TYP.) COMPACTED SUBGRADE 4" CONCRETE APRON #5 REBAR @ 1'-6" DEPTH IN UNDISTURBED SOIL. HAMMER SHARP END AND RECESS FROM TOP OF WHEELSTOP 1/2". (2) REBAR TOTAL AT 1'-0" FROM EACH END OF WHEELSTOP 3. 5 ' 40' 30' X X X St . S t a n i s l a u s C h u r c h 48 4 9 C a s t l e H a y n e R d Ca s t l e H a y n e , N o r t h C a r o l i n a Sheet Title: Sheet No: Revisions: Date: Project no: Seals: Corp. NC license: F-1320 1725-500693 04.04.2025 Y: \ N o r t h C a r o l i n a \ 1 7 X X - 5 0 S \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 _ M L A _ S t a n i s l a u s E x p \ E n g _ D o c s \ D r a w i n g s \ 1 7 2 5 - 5 0 0 6 9 3 . 0 0 - C D \ 1 7 2 5 - 5 0 0 6 9 3 - M A S T E R . d w g Al f r e d B e n e s c h & C o m p a n y 20 1 8 E a s t w o o d R d , S u i t e 1 1 1 W i l m i n g t o n , N C 2 8 4 0 3 ww w . b e n e s c h . c o m P 9 1 0 . 3 4 4 . 0 1 4 3 40 0 20 40 80 SCALE: 1"=40' NORTH Know what's below. before you dig.Call R LANDSCAPE PLAN C600 CASTLE HAYNE ROAD (NC 133) M A R A T H O N A V E N U E ( S R 1 3 3 7 ) PR O P O S E D F F E C BU I L D I N G 12 QS LEGEND LANDSCAPE REQUIREMENTS: STREET YARDS: N/A PARKING INTERIOR LANDSCAPING TREES REQUIRED (75% CANOPY, 1 TREE PER 144 SF): 11, PROVIDED: 11 GROSS PAVED AREA: 19,415 SF LANDSCAPE REQUIRED: 1,553 SF (19,415 SF X 8%) LANDSCAPE PROVIDED: 1,616 SF (8%) PARKING PERIMITER LANDSCAPING TREES REQUIRED: 1 PER 20 LF, PROVIDED: 17 FOUNDATION PLANTING: N/A FOUNDATION PLANTINGS: 12% AREA OF FIRST FLOOR FRONT BUILDING FACE LANDSCAPE NOTES 3 Foundation Groundcover Planting Detail N.T.S. MEASURED COMPRESSED ROTARY-TILL ORGANIC MATTER AND OTHER ADDITIVES INTO TOP 8" OF SOILSECTION STAGGERED PLANTING LAYOUT O.C. DIMENSION O.C. DIMENSION 1/2 O.C. DIMENSION CONTAINER SOIL BREAK SUBGRADE SOIL PLANT MATERIAL 1.MINIMUM TREE SIZE AT PLANTING IS 3" CALIPER DBH AND 8-10' FEET TALL FOR SINGLE-STEM CANOPY TREES. ALL MULTI-STEM PLANTS MUST BE TREE FORM, MAXIMUM 3 TO 5 TRUNKS, AND MINIMUM 10' TALL.. ALL UNDERSTORY TREES AT THE TIME OF PLANTING SHALL HAVE A MINIMUM 2' CALIPER DBH AND AN AVERAGE MINIMUM HEIGHT OF 10 FEET. 2.ALL NEW TREES MUST HAVE STRAIGHT TRUNKS WITH STRONG CENTRAL LEADERS INTACT TO THE TOP OF THE CROWN UNLESS MULTI-STEM TREES ARE SPECIFIED. ALL TREES SHALL BE TYPICAL OF THEIR SPECIES AND VARIETY, HAVE NORMAL GROWTH HABITS, HAVE WELL-DEVELOPED BRANCHES, BE VIGOROUS AND HAVE FIBROUS ROOT SYSTEMS. TREES WITH CO-DOMINANT BRANCHING WILL NOT BE ACCEPTED. TREES THAT HAVE BEEN SHEARED, TOPPED OR CUT BACK TO MULTIPLY THE BRANCHING STRUCTURE WILL NOT BE ACCEPTED. TREES SHALL BE FREE OF ABRASIONS, DAMAGE, DISEASE, PESTS AND CRACKS. ALL PRUNING CUTS GREATER THAN 12" DIAMETER SHALL HAVE CALLUS TISSUE FORMED PRIOR TO PLANTING. NO PRUNING CUT ON THE TRUNK SHALL BE MORE THAN ONE-HALF THE DIAMETER OF THE CENTRAL LEADER AT THE HEIGHT WHERE THE CUT WAS MADE. ROOT FLARES SHALL BE LOCATED AT GRADE. TREES WITH MORE THAN 2" OF SOIL COVERING THE ROOT BALL/FLARE FROM WILL NOT BE ACCEPTED. 3.SIZE OF PLANTS, SPREAD OF ROOTS AND SIZE OF BALLS SHALL BE IN ACCORDANCE WITH ANSI Z60.1 (LATEST EDITION) AS PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION. 4.ALL TREES OF A PARTICULAR SPECIES AND VARIETY SHALL BE UNIFORM IN SIZE AND CONFIGURATION. PLANTING REQUIREMENTS 5.PLASTIC HOSE PARTS WILL NOT BE ACCEPTED FOR TREE STAKING. SEE DETAILS AND SPECIFICATIONS FOR APPROVED STAKING METHOD/MATERIALS. 6.ALL STRAPPING, AND TOP 12 OF WIRE BASKET AND BURLAP MUST BE CUT AWAY AND REMOVED FROM ROOT BALL WHEN PLANTING. 7.FOR NEW PLANTING AREAS, REMOVE ALL PAVEMENT, GRAVEL SUB-BASE AND CONSTRUCTION DEBRIS; REMOVE COMPACTED SOIL AND ADD 24" NEW TOPSOIL, OR TILL AND AMEND THE TOP 24" OF EXISTING SOIL TO MEET TOPSOIL/ PLANTING MIX STANDARDS FOR TREES. 8.ALL SAUCERS SHALL BE SOAKED WITH WATER AND MULCHED IMMEDIATELY FOLLOWING PLANTING. 9.THE TOP OF ALL ROOT BALLS FOR SHRUBS & GROUNDCOVERS SHALL BEAR THE SAME RELATIONSHIP TO FINISHED GRADE, AS BORN TO PREVIOUS GROWING CONDITIONS. 10.ALL ROOT BALLS REMOVED FROM CONTAINERS SHALL BE SCARIFIED PRIOR TO BACKFILLING. 11.MULCH A MINIMUM 4 FOOT AREA AROUND EACH TREE AND - MULCH A CONTINUOUS AREA AROUND ALL SHRUB BEDS, AS INDICATED ON THE PLAN. MULCH SHALL BE 3-4" THICK. MULCH AROUND TREES SHALL BE TAPERED TOWARD TRUNK SO THAT NO MORE THAN 2" IS PLACED AT TREE TRUNK AS SHOWN ON DETAIL. SEE SPECIFICATIONS FOR TYPE. 12.SEE EROSION CONTROL PLANS FOR TEMPORARY SEEDING PLAN. 13.ALL DISTURBED AREAS SHALL BE SEEDED AND PERMANENTLY ESTABLISHED. UTILITY ISSUES 14.LARGE MATURING TREES MAY NOT BE PLANTED WITHIN 15' OF OVERHEAD POWER DISTRIBUTION OR TRANSMISSION LINES. IF TREES CONFLICT WITH POWER LINES OR SIGNS, CALL LANDSCAPE ARCHITECT TO RESOLVE BEFORE PLANTING. 15.CONTRACTOR IS RESPONSIBLE FOR HAVING ALL UNDERGROUND UTILITIES LOCATED AND CLEARLY PAINTED WITHIN 10 DAYS OF ANY GROUND DISTURBING ACTIVITY. OWNER WILL NOT PAY FOR UTILITY REPAIRS DUE TO FAILURE TO MARK AND OBSERVE UTILITY LOCATIONS. 16.ADJUST TREE PLANTING LOCATIONS TO AVOID UNDERGROUND UTILITIES- PLANT 10' FROM ALL UNDERGROUND UTILITIES (SEWER AND STORM DRAINAGE, GAS WATER, PHONE AND ELECTRICAL LINES). GENERAL 17.THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR THE QUANTITY OF PLANTS SHOWN ON THE PLAN. ANY DISCREPANCIES BETWEEN QUANTITIES ON PLAN AND PLANT LIST SHALL BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT AND ANY FIELD ADJUSTMENTS OR QUANTITY ADJUSTMENTS MUST BE AUTHORIZED PRIOR TO PLANTING. 18.ALL PLANTS SHALL BE GUARANTEED TO BE IN HEALTHY CONDITION FOR ONE (1) YEAR AFTER ACCEPTANCE BY OWNER OF ALL PLANT MATERIAL. 19.ALL DISTURBED AREAS SHALL BE SEEDED AS SPECIFIED. 20.SEE EROSION CONTROL/GRADING PLAN FOR ADDITIONAL TREE PRESERVATION NOTES. 21.CONTRACTOR TO SUBMIT IRRIGATION PLAN FOR APPROVAL PRIOR TO INSTALLATION. PROVIDE PVC SLEEVES TO LANDSCAPE AREAS IF IRRIGATIONS IS NOT INSTALLED PRIOR TO INSTALLATION OF HARDSCAPE. 1 Tree Planting N.T.S. MINIMUM TREE SIZE: MULTI-STEM 3-5 STEMS, 8' TALL MINIMUM TREE SIZE: SINGLE STEM 3" CALIPER, 10-12' TALL PLANTING REQUIREMENTS. REMOVE TOP 2/3 OF WIRE BASKET WHERE PRESENT AND ANY NAILS/PINS, ETC. REMOVE TOP 1/3 BURLAP PLANTING MIX (AS SPECIFIED) BERM OUTSIDE OF BACKFILL 4" MAXIMUM HIGH WATER 4" MAXIMUM LAYER OF MULCH THAN 3" . FIRM SOIL UNDER ROOT BALL. REJECT PLANTS WITH MORE FROM GROWER OVER ROOT FINISH GRADE DRIVEN IN LINE WITH STRAP RAISE PIT BOTTOM TO SET BUTTRESS ROOTS AT THE CORRECT HEIGHT. SYSTEM, UP TO 1" DEPTH. REMOVE TYPICAL EXCESS SOIL UNDISTURBED SOIL 6" SLIP KNOT WITH STOP KNOT. (6" LARGER THAN TREE DIAMETER) KEEP MULCH AWAY FROM TRUNK 1" TO 2" 3/4" NYLON STRAP STAKING REQUIRED CONTRACT. SEE GENERAL NOTES: SEE ATTACHED LANDSCAPE CONSTRUCTION STANDARDS FOR OTHER SOAK ROOT BALL AND PLANT PIT IMMEDIATELY AFTER INSTALLATION. REMOVE WIRE OR NYLON TWINE FROM BALL. BE AT FINISH GRADE 1" ROOT CROWN TO WITH CENTERED 3/8" HOLE 1"x2"x18" WOOD STAKE (FOR SINGLE AND MULTI-STEM TREES) FOR STREET TREES. 2 1/2" CALIPER, 8-10' IN LANDSCAPE BUFFERS. 2 Shrub Planting N.T.S. GRADEEXISTING THAT ARE POT BOUND IN CONTAINERIZED PLANTS CUT ROOTS AS NECESSARY EQUAL SPACING TAMP SOIL MIX UNDER MINIMIZE SETTLEMENT EACH PLANT BALL TO BETWEEN ALL PLANTS AMENDED NATIVE SOIL TYP. BED ROWS EDGE OF PLANTING FINAL EDGE OF MULCH MIN. 2" HT. MIN. 4" LAYER TYP. COLLAR OF APPROVED REMOVE ANY BROKEN OR DEAD AND DISEASED LIMBS "V" TRENCH AROUNDENTIRE PLANTING BED PLANTING BED GRADE SEE LANDSCAPE PLAN SPACING VARIES ADDITIONAL LANDSCAPE NOTES: 1.CANOPY AND UNDERSTORY TREES TO BE INSTALLED IN ACCORDANCE TO DETAIL 1 THIS PAGE. 2.SHRUBS TO BE INSTALLED IN ACCORDANCE TO DETAIL 2 THIS PAGE. 3.GROUNDCOVERS TO BE INSTALLED IN ACCORDANCE TO DETAIL 3 THIS PAGE. 4.CONTRACTOR TO SUBMIT PHOTOS OF PLANT MATERIAL AS SHOP DRAWINGS FOR APPROVAL. 5.ANY PROPOSED PLANT SPECIES SUBSTITUTIONS MUST BE REQUESTED IN WRITING TO THE DESIGNER OF RECORD FOR APPROVAL. 6.PLANTING PLAN PROVIDED REPRESENTS THE MINIMUM REQUIRED FOR COMPLIANCE WITH ZONING AND IS FOR INFORMATION ONLY. FINAL DESIGN MUST BE REVIEWED, PREPARED AND SEALED BY A NC LICENSED LANDSCAPE ARCHITECT. TREES QTY BOTANICAL / COMMON NAME ROOT CAL.REMARKS SIZE (MIN) B & B 2"-2.5" Cal.8-10` HT. SHRUBS QTY BOTANICAL / COMMON NAME CONT REMARKS HEIGHT SPREAD AZ 17 Rhododendron 'Gumpo' Series / Satsuki Azaleas #5 Container 4` O.C.18-24" HT.Ilex glabra / Inkberry Holly TURF BERMUDA SOD QP 22 Quercus phellos / Willow Oak Full Matched Specimen IG 10 #5 Container 4` O.C.18-24" HT. PLANTBSCHEDULE QP 22 IG 10 MG 6 AZ 17 MG 6 Muhlenbergia Capillaris 'Pink' / Muhly Grass 'Pink'#5 Container 4` O.C.18-24" HT. B & B 2"-2.5" Cal.8-10` HT.PC 3 Taxodium Ascendens / Pond Cypress CM 2 PC 3 B & B 2"-2.5" Cal.8-10` HT.CM 2 Lagerstroemia / Crape Myrtle SITE DATA: 1.PARCEL ID: R01700-003-003-000 2.PROJECT ADDRESS: 4849 CASTLE HAYNE ROAD CASTLE HAYNE, NC 28429 3.PROPERTY DEED AND PLAT DB: 6580 PG: 1906 MB: 61 PG: 56 4.SAINT STANISLAUS CATHOLIC PARISH OF CASTLE HAYNE 4849 CASTLE HAYNE ROAD CASTLE HAYNE, NC 28429 5.LAND USE: CURRENT LAND USE - CHURCH PROPOSED LAND USE -CHURCH 6.ZONING - RA (RURAL AGRICULTURE) 7.PARCEL ACREAGE: 41.98 AC 8.BUILDING SETBACKS: FRONT: 40 FEET SIDE: 30 FEET (STREET), 20 FEET (INTERIOR) REAR: 30 FEET 9.PARKING SPACES: EXISTING TO REMAIN:110 SPACES PROPOSED:38 SPACES TOTAL PARKING:148 SPACES (10 ADA ACCESSIBLE, 138 STANDARD)