HomeMy WebLinkAboutApplication_Lewis PlantationNEW HANOVER COUNTY
PLANNING & INSPECTIONS
DEPARTMENT
HIGH DENSITY APPLICA TION
FOR TRC REVIEW
APPLICATION #
230 Government Center Drive
Suite 110
Wilmington, NC 28403
910-798-7165 phone
910-798-7053fax
www.nhcRov.com
Petitioner Information
Property Owner(s)
Subject Property
-If different than Petitioner
Name
Owner Name
Address
Robbie B. Parker
McAdams Homes, LLC
4718 Gordon Road
Company
Owner Name 2
arcel ID 044-001 - 01z'0'09
Lee Law Firm PLLC
Address
Address
Acreage
3414 Wrightsville Avenue
6626-C Gordon Road
85.19 +/- acres
City, State, Zip
City, State, Zip
Existing Zoning and Use
Wilmington NC 28403
Wilmington NC 28405
B-2 & O&I
Phone
Phone
Proposed Zoning and Use
910-399-3447
910-798-3006
R-15 Single & Multi -family
Email
Email
Land Classification
robbie@leelawfirm.com
grady@mcadamshomes.net
R-15
SUBMISSION REVIEW PROCEDURES
Applications must be reviewed by the Technical Review Committee prior to submission for Planning
Board consideration. A fee of $300.00 per application will be charged. This fee is payable to New Hanover County
and MUST accompany this application. The application must also be accompanied by a site plan conforming to
the requirements of Section 69.2, Section 69.4 of the Zoning Ordinance and a special use permit application.
Applications for High Density Development are received and reviewed by New Hanover County Planning &
Zoning and applicable to State, County, and Federal agencies.
You are encouraged to arrange an informal pre -application conference with Planning & Zoning Staff at least
two weeks prior to the date upon which you intend to submit an application for TRC review. By attending this
conference, you will improve your chances of submitting a complete and acceptable application. You should bring a
rough sketch of your proposal to the conference. Planning & Zoning staff will proceed to:
1. Advise you of possible environmental concerns.
2. Generally describe the required improvements.
3. Point out significant design problems.
4. Advise you regarding the required approval letters.
5. Generally guide you in preparing the TRC submission.
6. Once completed, the High Density application and 15 copies of the site plan are submitted. New Hanover
County Planning & Zoning will send a copy to each appropriate reviewing agency. When written agency
comments have been received along with water and sewer letters, the site plan will be placed on the agenda
for the next regularly scheduled Technical Review Committee (TRC) meeting. Written agency comments
must be received three (3) weeks prior to the TRC meeting.
7. The required special use permit application may be submitted for Planning Board consideration at the next
published deadline following TRC recommendation on the site plan. A site plan checklist is available to
guide you through this process.
I certify that all information presented in this application is accurate to the best of my knowledge.
Signature of Petitioner or Property Owner Print Name
HID 4/10
NEW HANOVER COUNTY
PLANNING & INSPECTIONS
DEPARTMENT
HIGH DENSITY CHECKLIST &
DENSITY CALCULATIONS
Site Plan Requirements
❑ Scale no smaller than one inch to two hundred feet
❑ Vicinity or location map
❑ Name of designer, engineer, or surveyor
❑ North arrow and date
❑ Owner's name, address, and phone number on plan
❑ Developer (if other than owner) and development name
Boundary line of tract to be developed drawn accurately to scale with linear and angular dimensions
❑ Total gross acres in tract
❑ Total acres occupied by all structures including street right-of-way and parking areas
❑ Total acres & boundaries of land lying within the 100-year flood plain and below mean high water mark, plus
delineation of 100-year flood boundary
❑ Boundaries of all open space areas
❑ Location of all existing and proposed structures
❑ Total number of dwelling units to be constructed with number of bedrooms per unit and location of all multiple
dwelling units
❑ Location of right-of-way widths of all streets and easements (and other areas to be dedicated to public use)
❑ Location and width of all streets, plus names and designation
❑ Location and description of all recreational areas and facilities
❑ Location of natural features including topographical information (contour interval 2 feet), watercourses,
approximate forest lines and topo source
❑ Location and size of all proposed utility and drainage facilities
High Density Regulations
❑ Areas to be maintained by Homeowners Association clearly indicated on plan
❑ Physical Access to open space by all residents
❑ No economic restrictions on users
❑Direct access to minor or major arterial
❑ Required buffer yards shown on site plan
Compliance with Impervious Surface Ratio
❑ Compliance with Table of District Improvements (water, sewer, storm drainage, curb and gutter)
❑ Site in transition area
❑ Setbacks
❑ Parking complies with Article VIII of Zoning Ordinance
❑ Drainage plan approved
❑ Water supply/sewage disposal capacity approved
❑ Schedule for completion of improvements
❑ Conservation resources identified
❑ Air Quality/Complex Source Permit
❑ Approximate location of 404 Wetlands & Section 10 Wetlands
Subdivision Requirements: The following items must be shown on plan.
❑ Unduplicated development and street names
❑Names and locations of adjoining subdivisions, streets, adjacent property owners
❑ Roadway cross-section and drainage design
❑ Lot lines, lot numbers, and setback lines
❑ Location of Areas of Environmental Concern
❑ Block lengths greater than 400' but less than 1000'
❑ Blocks to have 2 tiers
Page 1 of 2
HDC 05110
Cul-de-sacs less than 500'
Drainage easements not less than 30' in width
Utility easements at least 15'
Street intersect not less than 800' apart
Street jogs are more than 200'
Side lot lines substantially at right angles or radical to street lines
Connections to adjacent streets (Street inter -connectivity)
Significant tree survey
TIA (100 peak hour trips or more)
Water/ Sewer Capacity Letters
Streetlights
Fire hydrant and locations
Sidewalks & Pedestrian easements
Double frontage lots shall be avoided
DENSITY CALCULATIONS
To Calculate the Base Site Area
Gross Site Area Less:
• Land used as open space in prior residential development
• Land used for commercial, office and institutional, and light industrial
purposes in the Planned Development District
• Water bodies and areas below mean water line if tidally or non -tidally influenced
• Previously approved open space
Equal Base Site Area
Density Allowance
Base Site Area
District Density Factor
R-10=17; R-15=10.2; R-20=4.25, 0&I=10.2
PD Inside Urban Transition=4.25
PD Outside Urban Transition=2.5
Equals Number of Units Permitted on Site
Page 2 of 2
85.19 acres/sq ft
- 0 acres/sq ft
- 0 acres/sq ft
- 0 acres/sq ft
- 17.44 acres/sq ft
= 67. 75 acres/sq ft
2951295 acres/sq ft
x 10.2
= 691
HDC 05/10