Loading...
HomeMy WebLinkAbout2_Sheetz - S Seabreeze Road - Response to TRC Comments - 2025.07.22 ENGINEERING | DESIGN | TECHNOLOGY 5410 Trinity Road Suite 102 Raleigh, NC 27607 P 919.866.4951 F 919.859.5663 www.timmons.com Date: 07-22-2025 Project: Sheetz – S Seabreeze Road SITECN-24-000072 Timmons Group Project #64250.005 Subject: Response to New Hanover County Technical Review Committee Comments Project Contact: Patrick Barbeau Phone: 919.866.4512 Email: Patrick.Barbeau@Timmons.com • Response to review comments have been added below each comment in bold font. Planning – Zach Dickerson – 05/07/2025 1. Though the rezoning was for the larger development, we do ask that any projects that are part of a rezoning have the conditions listed on the site plan. Please list out the following conditions on the site plan. These can be in an appendix or in a table on the plan. Response: The rezoning conditions have been listed in a table on the Cover sheet. C0.0. 2. Please note that because more than 25 parking spaces are provided, this site will require 20% of the required parking (15 * 20% = 3 parking spaces) to be EV-capable spaces. Please refer to UDO Section 5.1.2.D for EV Parking details. Response: 3 electric vehicle capable parking spaces have been noted on the plans. C2.0. 3. Street yard in the CB district requires 18 square feet for every linear foot of street yard frontage. This site abuts both Carolina Beach Road and S Seabreeze Road. Where sites have two road frontages, the secondary road frontage (in this case S Seabreeze Road), can be 50% of the street yard area. Response: Our street yard buffer is 14’ in accordance with the 50% reduction for secondary roads, from 18’ wide to 9’ wide, and the rezoning condition requiring an additional 5’ of street yard width on the southeast property line. 9’ + 5’ = 14’. C2.0. 4. Please note that a lighting plan is not required for TRC approval, but will be required prior to issuance of construction plan approvals. Response: Noted. Aspen Spring Response to City of Raleigh Review Comments Page 2 of 2 5410 Trinity Road Suite 102 Raleigh, NC 27607 P 919.866.4951 F 919.859.5663 www.timmons.com NCDOT – Nick Drees – 04/16/2025 1. Show and label the 10’ X 70’ NCDOT sight triangles. a. No obstructions shall be placed within the NCDOT sight triangles. Response: 10’x70’ Sight Triangles have been shown and labeled with no obstructions. C2.0. 2. Show and label the stopping sight distance. a. No obstructions shall be placed within the stopping sight distance. Response: Stopping Sight Distance has been shown and labeled with no obstructions. C2.0. 3. Label the internal protection stem length for the proposed driveway connection. a. Measured from the right-of-way line. Response: Internal protection stem length distance has been labeled. C2.0.