HomeMy WebLinkAbout6358 Myrtle Grove Road Site Plans1. THE CONSTRUCTION SITE IS NOT LOCATED IN A FEMA FLOOD HAZARDOUS ZONE.
FIRM # 3720313300K, 8/28/2018
2. THERE ARE WETLANDS AND SURFACE WATERS ON THE SITE WHICH HAVE BEEN DELINEATED.
3. PRIOR TO ANY CLEARING, GRADING OR CONSTRUCTION ACTIVITY, TREE PROTECTION FENCING SHALL BE
6. TRAFFIC CONTROL DEVICES (INCLUDING SIGNS AND PAVEMENT MARKINGS) IN AREAS
OPEN TO PUBLIC TRAFFIC ARE TO MEET MUTCD (MANUAL ON UNIFORM TRAFFIC CONTROL
DEVICES) STANDARDS.
7. IF THE CONTRACTOR DESIRES WATER FOR CONSTRUCTION, HE SHALL APPLY IN
MUST PROVIDE A REDUCED PRESSURE ZONE (RPZ)
DEVELOPER'S SIDE OF THE METER BOX. ANY BACKFLOW PREVENTION DEVICES REQUIRED WILL
NEED TO BE ON THE LIST OF DEVICES APPROVED BY USCFCCCHR OR ASSE.
8. ANY IRRIGATION SYSTEM SUPPLY BY CFPUA WATER SHALL COMPLY WITH THE CFPUA
CROSS CONNECTION CONTROL REGULATIONS.
9. CONTACT THE NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 PRIOR TO DOING ANY DIGGING,
10. THE BELLSOUTH CONTACT IS STEVE DAYVAULT. HE IS THE BUILDING INDUSTRY
CONSULTANT (910) 392-8712. PLEASE CONTACT HIM PRIOR TO STARTING THE PROJECT
IN ORDER TO FACILITATE GOOD COMMUNICATION AND MAXIMUM FLEXIBILITY.
11. ALL PLANTED AND RETAINED LIVING MATERIAL REQUIRED TO MEET THE PROVISIONS OF
NEW HANOVER COUNTY UNIFIED DEVELOPMENT ORDINANCE, SHALL BE PERPETUALLY
PROTECTED AND MAINTAINED TO PROFESSIONAL ACCEPTED STANDARDS BY JOINT AND SEVERAL
RESPONSIBILITY OF THE OWNER, TENANT AND RESPECTIVE AGENTS OF THE PROPERTY ON
WHICH THE MATERIAL IS LOCATED.
12. ANY PLANT MATERIAL THAT WAS PREVIOUSLY INSTALLED ON THE SITE TO MEET THE PROVISIONS
OF NEW HANOVER COUNTY UNIFIED DEVELOPMENT ORDINANCE THAT HAS NOT BEEN MAINTAINED
MAINTAINED MUST BE REPLACED.
13. AS PART OF THE FINAL ZONING INSPECTION FOR THIS PROJECT, A SURVEY OF THE SITE
LANDSCAPING WILL BE CONDUCTED. PLANT MATERIAL THAT HAS NOT BEEN MAINTAINED MUST
BE REPLACED BEFORE A FINAL ZONING APPROVAL IS ISSUED.
14. ALL PARKING STALL MARKINGS AND LANE ARROWS WITHIN THE PARKING AREAS SHALL BE WHITE.
ADVANCE FOR THIS SERVICE FROM CAPE FEAR PUBLIC UTILITY AUTHORITY (CFPUA) AND
BACKFLOW PREVENTION DEVICE ON THE
16. A RAIN/FREEZE SENSOR SHALL BE INSTALLED AS PART OF ANY IRRIGATION SYSTEM USED ON
THE SITE.
17. CONTACT TRAFFIC ENGINEERING AT 910-341-7888 48 HOURS PRIOR TO ANY EXCAVATION IN THE
RIGHT-OF-WAY TO ENSURE THAT ALL TRAFFIC SIGNAL FACILITIES AND EQUIPMENT ARE PROPERLY
15. ALL TRAFFIC CONTROL SIGNS AND MARKINGS OFF THE RIGHT-OF-WAY ARE TO BE MAINTAINED
BY THE PROPERTY OWNER IN ACCORDANCE WITH MUTCD STANDARDS.
18. AN ENCROACHMENT AGREEMENT AND DRIVEWAY PERMIT ARE REQUIRED FOR THIS PROJECT. NOTE
19. TACTILE WARNING MATS WILL BE INSTALLED ON ALL WHEELCHAIR RAMPS.
20. ANY BACKFLOW PREVENTION DEVICES REQUIRED BY THE CFPUA WILL NEED TO BE ON THE
LIST OF APPROVED DEVICES BY USCFCCCHR OR ASSE.
21. CONTRACTOR TO FIELD VERIFY EXISTING WATER AND SEWER SERVICE LOCATIONS, SIZES AND
MATERIALS PRIOR TO CONSTRUCTION. ENGINEER TO BE NOTIFIED OF ANY CONFLICTS.
22. CONTRACTOR SHALL MAINTAIN ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES
DURING CONSTRUCTION.
23. ALL PAVEMENT MARKINGS IN PUBLIC RIGHTS-OF-WAY AND FOR DRIVEWAYS ARE TO BE
THERMOPLASTIC AND MEET NCDOT STANDARDS.
24. NCDOT MUST APPROVE OF PAVEMENT MARKING PRIOR TO ACTUAL STRIPING.
25. ANY BROKEN OR MISSING SIDEWALK PANELS, DRIVEWAY PANELS AND CURBING WILL BE REPLACED.
26. PROJECT SHALL COMPLY WITH CFPUA CROSS CONNECTION CONTROL REQUIREMENTS. WATER
METER(S) CANNOT BE RELEASED UNTIL ALL REQUIREMENTS ARE MET AND THE STATE HAS
GIVEN THEIR FINAL APPROVAL. CALL 910-343-3910 FOR INFORMATION.
27. ALL NEW UTILITIES SHALL BE INSTALLED UNDERGROUND, EXCEPT WHERE SUCH PLACEMENT
IS PROHIBITIED OR DEEMED IMPRACTICAL BY THE UTILITY PROVIDER. UNDERGROUND TERMINAL
FACILITIES FOR STREET LIGHTING ALONG ALL PUBLIC STREETS ABUTTING THE SUBJECT SITE
SHALL BE INSTALLED BY THE DEVELOPER.
THIS ON THE PLAN AND CONTACT 341-5888 FOR MORE DETAILS. IN CERTAIN CASES AN ENTIRE
RESURFACING OF THE AREA BEING OPEN CUT MAY BE REQUIRED.
LOCATED.
NOTES:
INSTALLED AROUND PROTECED TREES OR GROVES OF TREES. NO CONSTRUCTION WORKERS, TOOLS,
MATERIALS, OR VEHICLES ARE PERMITTED WITHIN THE TREE PROTECTION FENCING.
4. ANY TREES AND/OR AREAS DESIGNATED TO BE PROTECTED MUST BE PROPERLY BARRICADED WITH
FENCING AND PROTECTED THROUGHOUT CONSTRUCTION TO INSURE THAT NO CLEARING, GRADING OR
STAGING OF MATERIALS WILL OCCUR IN THOSE AREAS.
5. NO EQUIPMENT IS ALLOWED ON SITE UNTIL ALL TREE PROTECTION FENCING AND SILT FENCING IS
OF THE PROJECT, AND CONTRACTORS SHALL RECEIVE ADEQUATE INSTRUCTION ON TREE PROTECTION
METHODS.
INSTALLED AND APPROVED. PROTECTIVE FENCING IS TO BE MAINTAINED THROUGHOUT THE DURATION
CLEARING OR GRADING.
28. WATER AND SEWER SERVICES WILL BE INSTALLED AND MEET CFPUA REQUIREMENTS.
29. UNDERGROUND FIRE LINE(S) MUST BE PERMITTED AND INSPECTED BY THE WILMINGTON FIRE DEPT.
FROM PUBLIC RIGHT-OF-WAY TO THE BUIDLING. CONTACT WILMINGTON FIRE DEPT. DIVISION OF FIRE
AND LIFE SAFETY AT 910-341-0696.
30. NO PARKING SPACES, FENCES, WALLS, POSTS, LIGHTS, SHRUBS, TREES OR OTHER TYPE OF
ABOVE THE GROUND WITHIN THE TRIANGULAR SIGHT DISTANCE.
31. SOLID WASTE DISPOSAL BY CONTRACTED WASTE SERVICE CONTRACTOR.
OBSTRUCTIONS NOT SPECIFICALLY EXEMPTED, SHALL BE PERMITTED IN THE SPACE BETWEEN THIRTY (30)
INCHES ABOVE GROUND AND TEN (10) FEET ABOVE GROUND WITHIN THE TRIANGULAR SIGHT DISTANCE.
1. CONTRACTOR SHALL MAINTAIN AN ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES DURING
CONSTRUCTION.
2. NEW HYDRANTS MUST BE BROUGHT INTO SERVICE PRIOR TO COMBUSTIBLE MATERIALS DELIVERED TO THE
3. A HYDRANT MUST BE WITHIN 150' OF THE FDC (MEASURED AS THE TRUCK DRIVES FOR PRACTICAL USE.)
FIRE AND LIFE SAFETY NOTES:
4. FDC MUST BE WITHIN 40' OF FIRE APPARATUS PLACEMENT.
5. LANDSCAPING OR PARKING CANNOT BLOCK OR IMPEDE FDC'S OR FIRE HYDRANTS. A 3-FOOT CLEAR SPACE
SHALL ALWAYS BE MAINTAINED AROUND THE CIRCUMFERENCE OF HYDRANTS AND FDC'S.
JOB SITE.
6. ADDITIONAL FIRE PROTECTION AND/OR ACCESSIBILITY REQUIREMENTS MAY BE REQUIRED DUE TO
ANY SPECIAL CIRCUMSTANCES CONCERNING THE PROJECT.
7. PRIVATE UNDERGROUND FIRE LINES REQUIRE A SEPARATE UNDERGROUND FIRE LINE PERMIT FROM
NEW HANOVER COUNTY FIRE AND LIFE SAFETY DIVISION 910-798-7420.
8. CONTRACTOR SHALL SUBMIT A RADIO SIGNAL STRENGTH STUDY FOR ALL MULTI-STORY COMMERCIAL BUILDINGS
EXCEEDING 7500 SF THAT DEMONSTRATES THAT EXISTING EMERGENCY RESPONDER RADIO SIGNAL LEVELS MEET
THE REQUIREMENTS OF SECTION 510 OF THE 2018 NC FIRE CODE.
9. ALL ISOLATION VALVES WITH THE "HOT BOX" AND BETWEEN THE "HOT BOX" AND THE RISER ROOM MUST BE
ELECTRICALLY SUPERVISED.
LOCATION MAP
LEGEND
POB 2
POB 1
EIP
EIP
EIP
EIP
EIP
EIPEIP
EIP
EIP
EIP
EIP
EIP
NIR
NIRNIR
NIR
NIR
NIR
NIR
NIR
MY
R
T
L
E
G
R
O
V
E
R
D
60
'
P
U
B
L
I
C
R
/
W
NIRNIR
NIR
EIP
EIP
EIP
NIR
NIR
NIR
EIP
NIR NIR
HIC
K
O
R
Y
K
N
O
L
L
SITE
Preliminary
LOCATION MAP
LEGEND
TRIP GENERATION
LAND USE CODE
ITE
GEN. OFFICE
INTENSITY VOLUMES
24 HR.
ENTER
PEAK
AM
EXIT
PEAK
AM
CHURCH
710
560
11.0 KSF2
9.11 KSF2
353
556
TOTAL 909
44
21
65
6
13
19
ENTER
PEAK
PM
EXIT
PEAK
PM
8
0
8
40
0
40
1. THE CONSTRUCTION SITE IS NOT LOCATED IN A FEMA FLOOD HAZARDOUS ZONE.
FIRM # 3720313300K, 8/28/2018
2. THERE ARE WETLANDS AND SURFACE WATERS ON THE SITE WHICH HAVE BEEN DELINEATED.
3. PRIOR TO ANY CLEARING, GRADING OR CONSTRUCTION ACTIVITY, TREE PROTECTION FENCING SHALL BE
6. TRAFFIC CONTROL DEVICES (INCLUDING SIGNS AND PAVEMENT MARKINGS) IN AREAS
OPEN TO PUBLIC TRAFFIC ARE TO MEET MUTCD (MANUAL ON UNIFORM TRAFFIC CONTROL
DEVICES) STANDARDS.
7. IF THE CONTRACTOR DESIRES WATER FOR CONSTRUCTION, HE SHALL APPLY IN
MUST PROVIDE A REDUCED PRESSURE ZONE (RPZ)
DEVELOPER'S SIDE OF THE METER BOX. ANY BACKFLOW PREVENTION DEVICES REQUIRED WILL
NEED TO BE ON THE LIST OF DEVICES APPROVED BY USCFCCCHR OR ASSE.
8. ANY IRRIGATION SYSTEM SUPPLY BY CFPUA WATER SHALL COMPLY WITH THE CFPUA
CROSS CONNECTION CONTROL REGULATIONS.
9. CONTACT THE NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 PRIOR TO DOING ANY DIGGING,
10. THE BELLSOUTH CONTACT IS STEVE DAYVAULT. HE IS THE BUILDING INDUSTRY
CONSULTANT (910) 392-8712. PLEASE CONTACT HIM PRIOR TO STARTING THE PROJECT
IN ORDER TO FACILITATE GOOD COMMUNICATION AND MAXIMUM FLEXIBILITY.
11. ALL PLANTED AND RETAINED LIVING MATERIAL REQUIRED TO MEET THE PROVISIONS OF
NEW HANOVER COUNTY UNIFIED DEVELOPMENT ORDINANCE, SHALL BE PERPETUALLY
PROTECTED AND MAINTAINED TO PROFESSIONAL ACCEPTED STANDARDS BY JOINT AND SEVERAL
RESPONSIBILITY OF THE OWNER, TENANT AND RESPECTIVE AGENTS OF THE PROPERTY ON
WHICH THE MATERIAL IS LOCATED.
12. ANY PLANT MATERIAL THAT WAS PREVIOUSLY INSTALLED ON THE SITE TO MEET THE PROVISIONS
OF NEW HANOVER COUNTY UNIFIED DEVELOPMENT ORDINANCE THAT HAS NOT BEEN MAINTAINED
MAINTAINED MUST BE REPLACED.
13. AS PART OF THE FINAL ZONING INSPECTION FOR THIS PROJECT, A SURVEY OF THE SITE
LANDSCAPING WILL BE CONDUCTED. PLANT MATERIAL THAT HAS NOT BEEN MAINTAINED MUST
BE REPLACED BEFORE A FINAL ZONING APPROVAL IS ISSUED.
14. ALL PARKING STALL MARKINGS AND LANE ARROWS WITHIN THE PARKING AREAS SHALL BE WHITE.
ADVANCE FOR THIS SERVICE FROM CAPE FEAR PUBLIC UTILITY AUTHORITY (CFPUA) AND
BACKFLOW PREVENTION DEVICE ON THE
16. A RAIN/FREEZE SENSOR SHALL BE INSTALLED AS PART OF ANY IRRIGATION SYSTEM USED ON
THE SITE.
17. CONTACT TRAFFIC ENGINEERING AT 910-341-7888 48 HOURS PRIOR TO ANY EXCAVATION IN THE
RIGHT-OF-WAY TO ENSURE THAT ALL TRAFFIC SIGNAL FACILITIES AND EQUIPMENT ARE PROPERLY
15. ALL TRAFFIC CONTROL SIGNS AND MARKINGS OFF THE RIGHT-OF-WAY ARE TO BE MAINTAINED
BY THE PROPERTY OWNER IN ACCORDANCE WITH MUTCD STANDARDS.
18. AN ENCROACHMENT AGREEMENT AND DRIVEWAY PERMIT ARE REQUIRED FOR THIS PROJECT. NOTE
19. TACTILE WARNING MATS WILL BE INSTALLED ON ALL WHEELCHAIR RAMPS.
20. ANY BACKFLOW PREVENTION DEVICES REQUIRED BY THE CFPUA WILL NEED TO BE ON THE
LIST OF APPROVED DEVICES BY USCFCCCHR OR ASSE.
21. CONTRACTOR TO FIELD VERIFY EXISTING WATER AND SEWER SERVICE LOCATIONS, SIZES AND
MATERIALS PRIOR TO CONSTRUCTION. ENGINEER TO BE NOTIFIED OF ANY CONFLICTS.
22. CONTRACTOR SHALL MAINTAIN ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES
DURING CONSTRUCTION.
23. ALL PAVEMENT MARKINGS IN PUBLIC RIGHTS-OF-WAY AND FOR DRIVEWAYS ARE TO BE
THERMOPLASTIC AND MEET NCDOT STANDARDS.
24. NCDOT MUST APPROVE OF PAVEMENT MARKING PRIOR TO ACTUAL STRIPING.
25. ANY BROKEN OR MISSING SIDEWALK PANELS, DRIVEWAY PANELS AND CURBING WILL BE REPLACED.
26. PROJECT SHALL COMPLY WITH CFPUA CROSS CONNECTION CONTROL REQUIREMENTS. WATER
METER(S) CANNOT BE RELEASED UNTIL ALL REQUIREMENTS ARE MET AND THE STATE HAS
GIVEN THEIR FINAL APPROVAL. CALL 910-343-3910 FOR INFORMATION.
27. ALL NEW UTILITIES SHALL BE INSTALLED UNDERGROUND, EXCEPT WHERE SUCH PLACEMENT
IS PROHIBITIED OR DEEMED IMPRACTICAL BY THE UTILITY PROVIDER. UNDERGROUND TERMINAL
FACILITIES FOR STREET LIGHTING ALONG ALL PUBLIC STREETS ABUTTING THE SUBJECT SITE
SHALL BE INSTALLED BY THE DEVELOPER.
THIS ON THE PLAN AND CONTACT 341-5888 FOR MORE DETAILS. IN CERTAIN CASES AN ENTIRE
RESURFACING OF THE AREA BEING OPEN CUT MAY BE REQUIRED.
LOCATED.
NOTES:
INSTALLED AROUND PROTECED TREES OR GROVES OF TREES. NO CONSTRUCTION WORKERS, TOOLS,
MATERIALS, OR VEHICLES ARE PERMITTED WITHIN THE TREE PROTECTION FENCING.
4. ANY TREES AND/OR AREAS DESIGNATED TO BE PROTECTED MUST BE PROPERLY BARRICADED WITH
FENCING AND PROTECTED THROUGHOUT CONSTRUCTION TO INSURE THAT NO CLEARING, GRADING OR
STAGING OF MATERIALS WILL OCCUR IN THOSE AREAS.
5. NO EQUIPMENT IS ALLOWED ON SITE UNTIL ALL TREE PROTECTION FENCING AND SILT FENCING IS
OF THE PROJECT, AND CONTRACTORS SHALL RECEIVE ADEQUATE INSTRUCTION ON TREE PROTECTION
METHODS.
INSTALLED AND APPROVED. PROTECTIVE FENCING IS TO BE MAINTAINED THROUGHOUT THE DURATION
CLEARING OR GRADING.
28. WATER AND SEWER SERVICES WILL BE INSTALLED AND MEET CFPUA REQUIREMENTS.
29. UNDERGROUND FIRE LINE(S) MUST BE PERMITTED AND INSPECTED BY THE WILMINGTON FIRE DEPT.
FROM PUBLIC RIGHT-OF-WAY TO THE BUIDLING. CONTACT WILMINGTON FIRE DEPT. DIVISION OF FIRE
AND LIFE SAFETY AT 910-341-0696.
30. NO PARKING SPACES, FENCES, WALLS, POSTS, LIGHTS, SHRUBS, TREES OR OTHER TYPE OF
ABOVE THE GROUND WITHIN THE TRIANGULAR SIGHT DISTANCE.
31. SOLID WASTE DISPOSAL BY CONTRACTED WASTE SERVICE CONTRACTOR.
OBSTRUCTIONS NOT SPECIFICALLY EXEMPTED, SHALL BE PERMITTED IN THE SPACE BETWEEN THIRTY (30)
INCHES ABOVE GROUND AND TEN (10) FEET ABOVE GROUND WITHIN THE TRIANGULAR SIGHT DISTANCE.
1. CONTRACTOR SHALL MAINTAIN AN ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES DURING
CONSTRUCTION.
2. NEW HYDRANTS MUST BE BROUGHT INTO SERVICE PRIOR TO COMBUSTIBLE MATERIALS DELIVERED TO THE
3. A HYDRANT MUST BE WITHIN 150' OF THE FDC (MEASURED AS THE TRUCK DRIVES FOR PRACTICAL USE.)
FIRE AND LIFE SAFETY NOTES:
4. FDC MUST BE WITHIN 40' OF FIRE APPARATUS PLACEMENT.
5. LANDSCAPING OR PARKING CANNOT BLOCK OR IMPEDE FDC'S OR FIRE HYDRANTS. A 3-FOOT CLEAR SPACE
SHALL ALWAYS BE MAINTAINED AROUND THE CIRCUMFERENCE OF HYDRANTS AND FDC'S.
JOB SITE.
6. ADDITIONAL FIRE PROTECTION AND/OR ACCESSIBILITY REQUIREMENTS MAY BE REQUIRED DUE TO
ANY SPECIAL CIRCUMSTANCES CONCERNING THE PROJECT.
7. PRIVATE UNDERGROUND FIRE LINES REQUIRE A SEPARATE UNDERGROUND FIRE LINE PERMIT FROM
NEW HANOVER COUNTY FIRE AND LIFE SAFETY DIVISION 910-798-7420.
8. CONTRACTOR SHALL SUBMIT A RADIO SIGNAL STRENGTH STUDY FOR ALL MULTI-STORY COMMERCIAL BUILDINGS
EXCEEDING 7500 SF THAT DEMONSTRATES THAT EXISTING EMERGENCY RESPONDER RADIO SIGNAL LEVELS MEET
THE REQUIREMENTS OF SECTION 510 OF THE 2018 NC FIRE CODE.
9. ALL ISOLATION VALVES WITH THE "HOT BOX" AND BETWEEN THE "HOT BOX" AND THE RISER ROOM MUST BE
ELECTRICALLY SUPERVISED.
MY
R
T
L
E
G
R
O
V
E
R
D
60
'
P
U
B
L
I
C
R
/
W
HIC
K
O
R
Y
K
N
O
L
L
SITE
Preliminary
Note: Sheriff's Traffic Control to be employed for all full congregation services.
LEGEND
1. THE CONSTRUCTION SITE IS NOT LOCATED IN A FEMA FLOOD HAZARDOUS ZONE.
FIRM # 3720313300K, 8/28/2018
2. THERE ARE WETLANDS AND SURFACE WATERS ON THE SITE WHICH HAVE BEEN DELINEATED.
3. PRIOR TO ANY CLEARING, GRADING OR CONSTRUCTION ACTIVITY, TREE PROTECTION FENCING SHALL BE
6. TRAFFIC CONTROL DEVICES (INCLUDING SIGNS AND PAVEMENT MARKINGS) IN AREAS
OPEN TO PUBLIC TRAFFIC ARE TO MEET MUTCD (MANUAL ON UNIFORM TRAFFIC CONTROL
DEVICES) STANDARDS.
7. IF THE CONTRACTOR DESIRES WATER FOR CONSTRUCTION, HE SHALL APPLY IN
MUST PROVIDE A REDUCED PRESSURE ZONE (RPZ)
DEVELOPER'S SIDE OF THE METER BOX. ANY BACKFLOW PREVENTION DEVICES REQUIRED WILL
NEED TO BE ON THE LIST OF DEVICES APPROVED BY USCFCCCHR OR ASSE.
8. ANY IRRIGATION SYSTEM SUPPLY BY CFPUA WATER SHALL COMPLY WITH THE CFPUA
CROSS CONNECTION CONTROL REGULATIONS.
9. CONTACT THE NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 PRIOR TO DOING ANY DIGGING,
10. THE BELLSOUTH CONTACT IS STEVE DAYVAULT. HE IS THE BUILDING INDUSTRY
CONSULTANT (910) 392-8712. PLEASE CONTACT HIM PRIOR TO STARTING THE PROJECT
IN ORDER TO FACILITATE GOOD COMMUNICATION AND MAXIMUM FLEXIBILITY.
11. ALL PLANTED AND RETAINED LIVING MATERIAL REQUIRED TO MEET THE PROVISIONS OF
NEW HANOVER COUNTY UNIFIED DEVELOPMENT ORDINANCE, SHALL BE PERPETUALLY
PROTECTED AND MAINTAINED TO PROFESSIONAL ACCEPTED STANDARDS BY JOINT AND SEVERAL
RESPONSIBILITY OF THE OWNER, TENANT AND RESPECTIVE AGENTS OF THE PROPERTY ON
WHICH THE MATERIAL IS LOCATED.
12. ANY PLANT MATERIAL THAT WAS PREVIOUSLY INSTALLED ON THE SITE TO MEET THE PROVISIONS
OF NEW HANOVER COUNTY UNIFIED DEVELOPMENT ORDINANCE THAT HAS NOT BEEN MAINTAINED
MAINTAINED MUST BE REPLACED.
13. AS PART OF THE FINAL ZONING INSPECTION FOR THIS PROJECT, A SURVEY OF THE SITE
LANDSCAPING WILL BE CONDUCTED. PLANT MATERIAL THAT HAS NOT BEEN MAINTAINED MUST
BE REPLACED BEFORE A FINAL ZONING APPROVAL IS ISSUED.
14. ALL PARKING STALL MARKINGS AND LANE ARROWS WITHIN THE PARKING AREAS SHALL BE WHITE.
ADVANCE FOR THIS SERVICE FROM CAPE FEAR PUBLIC UTILITY AUTHORITY (CFPUA) AND
BACKFLOW PREVENTION DEVICE ON THE
16. A RAIN/FREEZE SENSOR SHALL BE INSTALLED AS PART OF ANY IRRIGATION SYSTEM USED ON
THE SITE.
17. CONTACT TRAFFIC ENGINEERING AT 910-341-7888 48 HOURS PRIOR TO ANY EXCAVATION IN THE
RIGHT-OF-WAY TO ENSURE THAT ALL TRAFFIC SIGNAL FACILITIES AND EQUIPMENT ARE PROPERLY
15. ALL TRAFFIC CONTROL SIGNS AND MARKINGS OFF THE RIGHT-OF-WAY ARE TO BE MAINTAINED
BY THE PROPERTY OWNER IN ACCORDANCE WITH MUTCD STANDARDS.
18. AN ENCROACHMENT AGREEMENT AND DRIVEWAY PERMIT ARE REQUIRED FOR THIS PROJECT. NOTE
19. TACTILE WARNING MATS WILL BE INSTALLED ON ALL WHEELCHAIR RAMPS.
20. ANY BACKFLOW PREVENTION DEVICES REQUIRED BY THE CFPUA WILL NEED TO BE ON THE
LIST OF APPROVED DEVICES BY USCFCCCHR OR ASSE.
21. CONTRACTOR TO FIELD VERIFY EXISTING WATER AND SEWER SERVICE LOCATIONS, SIZES AND
MATERIALS PRIOR TO CONSTRUCTION. ENGINEER TO BE NOTIFIED OF ANY CONFLICTS.
22. CONTRACTOR SHALL MAINTAIN ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES
DURING CONSTRUCTION.
23. ALL PAVEMENT MARKINGS IN PUBLIC RIGHTS-OF-WAY AND FOR DRIVEWAYS ARE TO BE
THERMOPLASTIC AND MEET NCDOT STANDARDS.
24. NCDOT MUST APPROVE OF PAVEMENT MARKING PRIOR TO ACTUAL STRIPING.
25. ANY BROKEN OR MISSING SIDEWALK PANELS, DRIVEWAY PANELS AND CURBING WILL BE REPLACED.
26. PROJECT SHALL COMPLY WITH CFPUA CROSS CONNECTION CONTROL REQUIREMENTS. WATER
METER(S) CANNOT BE RELEASED UNTIL ALL REQUIREMENTS ARE MET AND THE STATE HAS
GIVEN THEIR FINAL APPROVAL. CALL 910-343-3910 FOR INFORMATION.
27. ALL NEW UTILITIES SHALL BE INSTALLED UNDERGROUND, EXCEPT WHERE SUCH PLACEMENT
IS PROHIBITIED OR DEEMED IMPRACTICAL BY THE UTILITY PROVIDER. UNDERGROUND TERMINAL
FACILITIES FOR STREET LIGHTING ALONG ALL PUBLIC STREETS ABUTTING THE SUBJECT SITE
SHALL BE INSTALLED BY THE DEVELOPER.
THIS ON THE PLAN AND CONTACT 341-5888 FOR MORE DETAILS. IN CERTAIN CASES AN ENTIRE
RESURFACING OF THE AREA BEING OPEN CUT MAY BE REQUIRED.
LOCATED.
NOTES:
INSTALLED AROUND PROTECED TREES OR GROVES OF TREES. NO CONSTRUCTION WORKERS, TOOLS,
MATERIALS, OR VEHICLES ARE PERMITTED WITHIN THE TREE PROTECTION FENCING.
4. ANY TREES AND/OR AREAS DESIGNATED TO BE PROTECTED MUST BE PROPERLY BARRICADED WITH
FENCING AND PROTECTED THROUGHOUT CONSTRUCTION TO INSURE THAT NO CLEARING, GRADING OR
STAGING OF MATERIALS WILL OCCUR IN THOSE AREAS.
5. NO EQUIPMENT IS ALLOWED ON SITE UNTIL ALL TREE PROTECTION FENCING AND SILT FENCING IS
OF THE PROJECT, AND CONTRACTORS SHALL RECEIVE ADEQUATE INSTRUCTION ON TREE PROTECTION
METHODS.
INSTALLED AND APPROVED. PROTECTIVE FENCING IS TO BE MAINTAINED THROUGHOUT THE DURATION
CLEARING OR GRADING.
28. WATER AND SEWER SERVICES WILL BE INSTALLED AND MEET CFPUA REQUIREMENTS.
29. UNDERGROUND FIRE LINE(S) MUST BE PERMITTED AND INSPECTED BY THE WILMINGTON FIRE DEPT.
FROM PUBLIC RIGHT-OF-WAY TO THE BUIDLING. CONTACT WILMINGTON FIRE DEPT. DIVISION OF FIRE
AND LIFE SAFETY AT 910-341-0696.
30. NO PARKING SPACES, FENCES, WALLS, POSTS, LIGHTS, SHRUBS, TREES OR OTHER TYPE OF
ABOVE THE GROUND WITHIN THE TRIANGULAR SIGHT DISTANCE.
31. SOLID WASTE DISPOSAL BY CONTRACTED WASTE SERVICE CONTRACTOR.
OBSTRUCTIONS NOT SPECIFICALLY EXEMPTED, SHALL BE PERMITTED IN THE SPACE BETWEEN THIRTY (30)
INCHES ABOVE GROUND AND TEN (10) FEET ABOVE GROUND WITHIN THE TRIANGULAR SIGHT DISTANCE.
1. CONTRACTOR SHALL MAINTAIN AN ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES DURING
CONSTRUCTION.
2. NEW HYDRANTS MUST BE BROUGHT INTO SERVICE PRIOR TO COMBUSTIBLE MATERIALS DELIVERED TO THE
3. A HYDRANT MUST BE WITHIN 150' OF THE FDC (MEASURED AS THE TRUCK DRIVES FOR PRACTICAL USE.)
FIRE AND LIFE SAFETY NOTES:
4. FDC MUST BE WITHIN 40' OF FIRE APPARATUS PLACEMENT.
5. LANDSCAPING OR PARKING CANNOT BLOCK OR IMPEDE FDC'S OR FIRE HYDRANTS. A 3-FOOT CLEAR SPACE
SHALL ALWAYS BE MAINTAINED AROUND THE CIRCUMFERENCE OF HYDRANTS AND FDC'S.
JOB SITE.
6. ADDITIONAL FIRE PROTECTION AND/OR ACCESSIBILITY REQUIREMENTS MAY BE REQUIRED DUE TO
ANY SPECIAL CIRCUMSTANCES CONCERNING THE PROJECT.
7. PRIVATE UNDERGROUND FIRE LINES REQUIRE A SEPARATE UNDERGROUND FIRE LINE PERMIT FROM
NEW HANOVER COUNTY FIRE AND LIFE SAFETY DIVISION 910-798-7420.
8. CONTRACTOR SHALL SUBMIT A RADIO SIGNAL STRENGTH STUDY FOR ALL MULTI-STORY COMMERCIAL BUILDINGS
EXCEEDING 7500 SF THAT DEMONSTRATES THAT EXISTING EMERGENCY RESPONDER RADIO SIGNAL LEVELS MEET
THE REQUIREMENTS OF SECTION 510 OF THE 2018 NC FIRE CODE.
9. ALL ISOLATION VALVES WITH THE "HOT BOX" AND BETWEEN THE "HOT BOX" AND THE RISER ROOM MUST BE
ELECTRICALLY SUPERVISED.
POB 2
POB 1
EIP
EIP
EIP
EIP
EIP
EIPEIP
EIP
EIP
EIP
EIP
EIP
NIR
NIRNIR
NIR
NIR
NIR
NIR
NIR
MY
R
T
L
E
G
R
O
V
E
R
D
60
'
P
U
B
L
I
C
R
/
W
NIRNIR
NIR
EIP
EIP
EIP
NIR
NIR
NIR
EIP
NIR NIR
HIC
K
O
R
Y
K
N
O
L
L
Preliminary
CHURCH LANDSCAPING
OFFICE & STREETYARD LANDSCAPING
VEHICULAR USE AREA = 19,460 SF
OFFICE PARKING LANDSCAPING CALCULATIONS
LANDSCAPE ISLAND AREA PROVIDED = 1,573 SF
TOTAL FRONTAGE = 826.94'
STREETYARD CALCULATIONS
826.94 - 104.1 = 767.84'
767.84 X 12 = 9,214 SF STREETYARD REQUIRED
DRIVEWAY WIDTHS AT R/W: 38.24 + 33.32 + 32.54 = 104.1'
129 + 5,869 + 624 +1,269 + 1,737 = 9,628 SF PROVIDED
CHURCH FRONT (SOUTH) FACADE: 302' x 25' = 7,550 x .12 = 906 SF REQUIRED
FOUNDATION PLANTING CALCULATIONS
CHURCH WEST SIDE FACADE: 159' x 25' = 3975 x .12 = 477 SF REQUIRED
VEHICULAR USE AREA = 299,084 SF
CHURCH PARKING LANDSCAPING CALCULATIONS
8% IS REQUIRED: 299,084 x .08 = 23,927 SF REQUIRED
LANDSCAPE ISLAND AREA PROVIDED = 26,845 SF
8% IS REQUIRED: 19,460 x .08 = 1,556.8 SF REQUIRED
75% MUST BE CANOPY TREES
1,573 / 144 = 10 TREES REQUIRED AND PROVIDED
10 x .75 = 7.5 CANOPY TREES, 8 ARE PROVIDED
CHURCH FRONT (SOUTH) FACADE: 78' x 14' = 1,092 x .12 = 131 SF REQUIRED
906 SF + 131 SF = 1,037 SF REQUIRED
1,575 x 2 = 3,150 SF PROVIDED
587 SF PROVIDED
CHURCH BACK (NORTH) FACADE: 302' x 25' = 7,550 x .12 = 906 SF REQUIRED
CHURCH BACK (NORTH) FACADE: 78' x 14' = 1,092 x .12 = 131 SF REQUIRED
906 SF + 131 SF = 1,037 SF REQUIRED
1,295 + 503 + 1,248 = 3,046 SF PROVIDED
CHURCH EAST SIDE FACADE: 159' x 25' = 3975 x .12 = 477 SF REQUIRED
587 SF PROVIDED
75% MUST BE CANOPY TREES
26,845 / 144 = 186 TREES REQUIRED AND PROVIDED
186 x .75 = 140 CANOPY TREES ARE REQUIRED
151 CANOPY TREES ARE PROVIDED
1. LARGE CANOPY AND MITIGATION TREES TO BE MIN. 2" DBH AT PLANTING.
2. SMALL CANOPY TREES TO BE MINIMUM 8' TALL AT PLANTING.
3. SHRUBS TO BE MIN. 12" TALL AT TIME OF PLANTING.
4. APPLY NATURAL MULCH 4" DEEP TO TOTAL LANDSCAPE ISLANDS AND 4' DIAMETER AROUND OTHER
LANDSCAPE NOTES
5. ALL OTHER DISTURBED AREAS SHALL BE SOWN OR SODDED.
6. NOTHING SHALL BE PLANTED WITHIN THE SIGHT DISTANCE TRIANGLE WHICH WOULD IMPEDE VISION
INTERIOR TREES
BETWEEN A HEIGHT OF 2.5' AND 10'
7. LANDSCAPE ISLANDS MUST HAVE A MINIMUM WIDTH OF 12' FROM BACK OF CURB TO BACK OF CURB.
8. DO NOT MIX VARIETIES OF AZALEAS IN FOUNDATION PLANTING.
DD D DD D
M MM MM M
D
AAA
A A A A
A
A A AAAAA A A AAAAAAAAAA
A
A
A
D
Z
C CC
Z
Z Z
Z
Z
Z Z Z ZZ
Z Z Z C C C
C C C
D D
*
***D
DD
D
D
MYRTLE GROVE RD
60' PUBLIC R/W
********
***
**********
*******
***
D D
LANDSCAPING LEGEND
SYMBOL
DARLINGTON OAK
QUERCUS LAURIFOLIA
HEIGHT 30-50
SPREAD 25-30
SPECIFICATION QUANTITY
SOUTHERN MAGNOLIA
MAGNOLIA GRANDIFLORA
HEIGHT 50-60
SPREAD 30-40
BUFFER OFFICE OFFICE TOTAL
4 53
ADDITIONALLARGE CANOPY
SMALL CANOPY BUFFER PARKING FOUNDATION TOTALADDITIONAL
RED MAPLE
ACER RUBRUM
HEIGHT 40-60
SPREAD 30-50
CRAPE MYRTLE
LAGERSTROEMIA INDICA
HEIGHT 25
SPREAD 12-15
19
40
30
SUGAR MAPLE
ACER SACCHARUM
HEIGHT 60-80
SPREAD 40-60
EASTERN RED BUD
CERCIS CANADENSIS
HEIGHT 20-25
SPREAD 15-20
SHRUBS BUFFER PARKING FOUNDATION TOTALADDITIONAL
FOUNTAIN GRASS
PENNISETUM SETACEUM
HEIGHT 2-5
SPREAD 2-4
DWARF GARDENIA
GARDENIA JASMINOIDES
'RADICANS'
HEIGHT 1-2
SPREAD 2-4
INDIAN HAWTHORNE
RHAPHIOLEPSIS INDICA 'CONOR'
'ELEANOR TABOR'
HEIGHT 3-5
SPREAD 2-3
SOUTHERN WAX MYRTLE
MORELLA CERIFERA
HEIGHT 7.5-12.5
SPREAD 6-10
VARIGATED PITTOSPORUM
PITTISPORUM TOBIRA 'VARIEGATA'
HEIGHT 8-12
SPREAD 12-18
*EMERALD GREEN ARBORVITAE
THUJA OCCIDENTALIS 'EMERALD'
HEIGHT 10-15
SPREAD 3-4
4
42
2 2
2
20
8
20 20
35
TREE PROTECTION FENCING
MISC.
STREETYARD
STREETYARD
STREETYARD
INDICA AZALEA
RHODODENDRON 'GEORGE TABOR'
HEIGHT 6-12
SPREAD 6-8
SNOWBALL VIBURNUM
VIBURNUM OPULUS
HEIGHT 8-15
SPREAD 10-15
26
38
15INDICA AZALEA
RHODODENDRON 'FORMOSA'
HEIGHT 6-12
SPREAD 6-8
20
8
18
15
6
4
4
232
GREEN ASH
FRAXIMUS PENNSYLVANICA
HEIGHT 60-80
SPREAD 40-50
21
14
4
FLOWERING DOGWOOD
CORNUS FLORIDA
HEIGHT 15-30, SPREAD 15-30
9
D
2
8
10
8
6
PARKING FOUNDATION
CHURCH CHURCH
43
PARKING FOUNDATION
26
15
PARKING FOUNDATION
36
34
2
49
21
7 2
4
4
14
PARKING FOUNDATION
VARIEGATED LILY TURF
LIRIOPE MUSCARI 'VARIEGATA'
HEIGHT 1-1.5
SPREAD 1-2
46
VARIEGATED DAPHNE
DAPHNE ODORA 'AUREO MARGINATA'
HEIGHT 3-4
SPREAD 3-4
6D
DWARF MAHONIA
MAHONIA EURYBRACTEATA
'SOFT CARESS'
HEIGHT 3
SPREAD 3-5
M
A DWARF 'ENCORE' AZALEA
RHODODENDRON 'AUTUMN CHIFFON'
OR 'AUTUMN CORAL' SEE NOTE # ???
HEIGHT 2-3
SPREAD 3-4
Z 'ENCORE' AZALEA
RHODODENDRON 'AUTUMN TWIST'
OR 'AUTUMN CARNATION' SEE NOTE # 8
HEIGHT 4-6
SPREAD 3-4
JAPANESE CHERRY
PRUNUS SERRULATA
HEIGHT 15-25
SPREAD 15-25
4
30
14
C CAMELLIA SASANQUA
'OCTOBER MAGIC INSPIRATION'
OR 'OCTOBER MAGIC DAWN' SEE NOTE # 8
HEIGHT 4-8
SPREAD 3-5
6
49
46
8
6
6 6
30
14
6
LANDSCAPE AREA BOUNDARY
LANDSCAPE AREA SQUARE FOOTAGE
EX. 8" AND 15" OAKS
EX. 8" AMERICAN HOLLY
2
1
Preliminary