Loading...
HomeMy WebLinkAboutNHCo TRC Response Preliminary Plan TRC Compiled Comments To: Marlowe Foster, Cape Fear Habitat for Humanity, marlowefoster@capefearhabitat.org From: Ryan Beil, Development Review Planner Date: June 18, 2025 TRC Review PID#: R02500-003-097-000 Egov# SUBPP-25-0025 Subject: Legacy Landing Phase 2- Preliminary Plan TRC Review The following comments have been received for the June 18, 2025, TRC meeting. Additional comments may be made upon further review of subsequent revisions. Please note: following the TRC meeting, a revised preliminary plan addressing each of the items below must be resubmitted before receiving preliminary plan approval. Planning, Ryan Beil 910-798-7444 1. General Comments a. Currently Conditionally Zoned R-10, housing type proposed are single-family detached and single-family attached. b. Phase II is a performance subdivision. i. Density for Performance Residential: 3.1 dwelling units per acre within R-10 in a Performance Residential Subdivision. ii. There are no Class IV soils or wetlands on the property. iii. Density calculations: 1. Total site acreage = 7.65 acres 2. R-10 Zoning District allows maximum 3.1 dwelling units per acre under performance residential subdivision. 3. Developable site acreage (7.65) * zoning density (3.1) = 24 units c. As this project was part of a conditional rezoning, the conditions on the site are as follows: i. A six foot tall solid wood privacy fence shall be installed along the eastern boundary of 1716 Rockhill Road also identified as New Hanover County Tax Parcel ID R02500-003-102-000 ii. The permitted density range is 0 dwelling units per acre to a maximum of 3.1 dwelling units per acre. Planning staff is authorized to administratively approve reductions in density within the permitted range. iii. The housing types in the development shall be limited to detached single-family dwellings and dual unit attached dwellings as defined in Section 2.3 of the Unified Development Ordinance. d. Staff recommend including the location of traffic calming devices on the preliminary plans. Installation of traffic calming devices are not required, but including potential locations on the plan ensures the future HOA / owners will have the opportunity to install them without conducting a traffic study. 2. UDO Section 5.1, Parking and Loading a. Per table 5.1.2.A in the County UDO, there are 2 off street parking spots required for each dwelling, which the site plan shows meaning the requirement is met. 3. UDO Section 5.2, Traffic, Access and Connectivity Please note that no building permit for any structure shall be issued which requires NCDOT approval for a Driveway Permit until NCDOT has issued the permit approval. Evidence of approval shall accompany the application for building permit. Submittal has been made to NCDOT for Driveway Permit. 4. UDO Section 5.3, Tree Retention a. Note: Land disturbance permits can be issued by county Engineering before a Tree Removal Permit is approved by Planning. However, any trees removed before the Tree Removal Permit is issued may result in enforcement action under Section 5.3.2 of the Unified Development Ordinance to include prohibiting any development of the site for 3 to 5 years. Are any trees planned to be removed for this project? If so, please apply for a Tree Removal Permit: https://www.nhcgov.com/DocumentCenter/View/1239/Tree-Removal- Permit-PDF Trees to be removed are shown on Sheet C2. Tree removal permit application is enclosed. 5. UDO Section 5.4, Landscaping and Buffering a. Landscaping and buffering are only required for the amenity areas, however a listed condition from this conditional rezoning requires a six foot tall solid wood privacy fence shall be installed along the eastern boundary of 1716 Rockhill Road also identified as New Hanover County Tax Parcel ID R02500-003-102-000. b. Please show the location of the fence on the site plan to ensure the condition is met. Fence is not in the signed conditional rezoning agreement. 6. UDO Section 5.5, Lighting Please note under 5.5.2.A that a lighting plan is not required for single-family residential projects and the county does not require streetlights however a lighting plan is required for any amenity area, if any lighting is planned there. No amenity area is proposed. 7. UDO Section 5.6, Signs There appears to be an area of open space near the entrance, please confirm if this will be where the sign is placed. Yes, sign will be located in the open space area near the entrance. 8. UDO Section 5.7, Conservation Resources a. Per the New Hanover County Conservation Resource Map there are no Conservation Resources present on this property. 9. UDO Section 5.8, Open Space Requirements a. There is .967 of an acre, or 42,129 square feet, of open space provided. The open space requirement from our UDO in performance residential development is 20% of acreage, which in this circumstance would equate to 24,219 square feet or .56 acres, meaning the open space requirement has been met. 10. UDO Article 6, Subdivision Design and Improvements. a. R-10 developments require sidewalks with a 5’ minimum width, please label them sidewalks on the site plan. 5’ sidewalk has been added and labeled. b. Block length is below listed maximum of 1,000 ft. c. Per the County UDO any subdivision shall achieve a connectivity ratio of no less than 1.40. 11. UDO Article 9, Flood Damage Prevention a. No part of the property is in a flood zone. NHC Fire Services, Ray Griswold 910-798-7448 1. Fire finals required 2. County Fire approves site plan NHC Soil & Water Conservation, Dru Harrison 910-798-7135 1. Comments attached NHC Engineering, Galen Jamison 910-798-7072 1. A land disturbing permit issued by the County is required for this project since the anticipated limits of disturbance is greater than 1 acre. Please digitally submit the permit application documentation with requisite review fees for County issued permit directly to gjamison@nhcgov.com. Application and forms can be found at https://www.nhcgov.com/249/Sediment-Erosion-Contr ol. Land disturbing permit is under review. 2. A revision to County stormwater permit STMW-21-0003 will be required for this project. Please digitally submit the permit applications documentation with requisite review fees to the COAST online permit portal (https://newhanovercountync- energovpub.tylerhost.net/apps/selfservice#/home). Applicable forms can be found at https://www.nhcgov.com/251/Stormwater however the application form is not required as the information will be gathered by the COAST portal. County stormwater is under review. 3. Please contact the State for their stormwater permit requirements. A high density permit is anticipated. State stormwater is under review. NHC Environmental Health, Dustin Fenske 910-798-6732 1. Site plan reflects connection to public water. Proposed infrastructure does not violate setbacks to any surrounding properties drinking water wells. NHC Addressing, McCabe Watson 910-798-7068 1. Each dwelling will need its own individual address. 2. Please contact me for address assignments following TRC approval. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 1. CFPUA TRC Comments provided are preliminary comments only. 2. Utility Plan review will be required by CFPUA. CFPUA is moving toward becoming paperless. When ready to submit plan review package, upload all documents to https://www.cfpua.org/FormCenter/Engineering-3/Engineering-Plan-Review-103. 3. CFPUA sewer is available 4. CFPUA water and sewer are available via a mainline extension. 5. Capacity is dependent on the analysis of the pipe collection system (gravity and force mains). 6. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE Application Form and a Preliminary Plan, this determination does not guarantee capacity. 7. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the Authority. Utility plans are under review with CFPUA. NCDOT, Nick Drees 910-343-3915 1. Comments attached WMPO, Caitlin Cerza 910-341-0107 1. Comments attached Army Corps of Engineers, Brad Shaver 910-251-4611 1. The Corps does not have any records on this site. Please reach out to the ACOE if there are wetlands impact questions. No wetland impacts are proposed. Project information also provided to the following state agencies and non-development regulatory local agencies for their awareness: New Hanover County Emergency Management New Hanover County Schools NC Department of Environmental Quality (DEQ) NC DEQ Division of Coastal Management NC DEQ Division of Energy, Mineral, and Land Resources / TO: New Hanover County Planning Department, New Hanover SWCD, May 12th, 2025 FROM: Dru Harrison, Director RE: I HAVE REVIEWED THIS PLAN AS REQUESTED AND HAVE THESE COMMENTS: The soils are predominantly Lynchburg fine sandy loam (Ls), Onslow loamy fine sand (On), and Woodington fine sandy loam (Wo). According to the booklet, “Wilmington/New Hanover Classification of soils for Septic Tank Suitability Lynchburg, Onslow, and Woodington are Class II soils. The Soil Survey of New Hanover County lists Lynchburg, Onslow as somewhat poorly drained, and Woodington as poorly drained. Woodington is on the New Hanover County Hydric Soils A list which means they are possibly wetland areas and subject to regulation under the Clean Water Act. Lynchburg is on the Hydric Soils B list, which means it may contain areas of wetland. It should be noted, according to the Soil Survey of New Hanover County, the limitation for dwellings with or without basements and for small commercial buildings is severe for all of the soils on this site. The limitations are due to flooding and/or wetness. An adequate drainage and maintenance plan is needed for suitable housing. Stormwater management plan is under review. The U.S. Army Corps of Engineers has federal jurisdiction over 404 Permits and the NCDEHNR, Dept. of Water Quality, has state jurisdiction over 401 Permits under the Clean Water Act. Before disturbing possible wetland areas, developers should contact these agencies to stay in compliance with State and Federal regulations. No wetlands exist on site. / STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION JOSH STEIN J.R. “JOEY” HOPKINS GOVERNOR SECRETARY Memorandum To: New Hanover County Technical Review Committee Date: June 4, 2025 Subject: Lagacy Landing II – 1728 Rockhill Road These are preliminary comments and are based on the plans as submitted for the proposed site. They are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. General Comments: NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT Online Portal.https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx You can coordinate with the district office with any questions 910-398-9100. NCDOT Driveway Permit: An NCDOT Driveway Permit is required. Submit plans in accordance with pages 14 and 15 of the Policy on Street and Driveway Access to North Carolina Highways to include access locations within 500’ of the proposed access on both sides of the State Road. Submit to the local NCDOT District Engineer’s Office. • Refer to the NCDOT checklist (included) for required documents and site plan information. Driveway permit application has been submitted. NCDOT Encroachment Agreement: An NCDOT Encroachment Agreement is required for any utility connections or installations within the NCDOT right-of-way (form 16.6). • Refer to the NCDOT UAM Manual and the NCDOT encroachment checklist for required documents and site plan information. An NCDOT Encroachment Agreement is required for any sidewalk or multi-use paths installed within the NCDOT right-of-way (form 16.6). NCDOT Encroachment Agreement has been submitted. Site Plan Comments: Include/update the NCDOT Standard Drawings (2024) that are applicable to the development. Sight Triangles and Sight Distance: • Show and label the 10’ X 70’ NCDOT sight triangles. o No obstructions shall be placed within the NCDOT sight triangles. • Show and label the stopping sight distance. o No obstructions shall be placed within the stopping sight distance. Identification Signing and Landscaping: • Identification signing or landscape vegetation within the median and the sight distance triangle must not obstruct the driver’s line of sight. No landscaping or signing will be allowed to exceed 42 inches in height, measured from the Edge of Pavement (EOP) within the median or sight triangle. • All pylon signs in the median or sight distance triangle must provide a vertical clear sight zone between 3 feet-6 inches and 10 feet-0 inches measured from the EOP. Signing located within a clear recovery area shall be of a “breakaway design.” • Only low growing shrubbery, consistent with the NCDOT’s landscaping policies, as contained in the publication “Guidelines for Planting Within Highway Right of Way,” will be allowed within a landscaped median and the sight distance triangle at the entranceway to a development, whether the street or driveway connection to the State Highway System is designated as a public facility or not. Landscaping within the right-of-way and sight distance triangles may require additional approval by the District Engineer. Label the radii for the driveway proposed driveway/driveways. • Make sure to accommodate the largest proposed vehicle. Label the internal protection stem length for the proposed driveway connection. • Measured from the right-of-way line. Site plans are under review with NCDOT / MEMORANDUM To: New Hanover County Technical Review Committee Date: June 5, 2025 Subject: Legacy Landing Phase 2 – 1728 Rockhill Road (SUBPP-25-0025) / NCDOT Projects:  N/A WMPO 2045 MTP Projects:  N/A New Hanover County Projects:  N/A TIA: Based on the 11th edition ITE Trip Generation Manual, a TIA is not required. Land Use (ITE Code)  Intensity  Unit  24 Hour Volumes  AM Peak Hour Trips  PM Peak Hour Trips  Single Family Attached Housing (215)  14  DU  56  2  4   Noted. /