Loading...
HomeMy WebLinkAboutHeron Cove Site PlanOPEN SPACE & STORMWATER POND AREA PROPOSED ENTRANCE FEATURE (BY OTHERS) PROP O S E D OPEN S P A C E 10' M.U.P. NC G R I D N A D 8 3 ( N S R S 2 0 1 1 ) WETLAND AREA FLAGGED BY SOUTHERN ENVIRONMENTAL GROUP SITE DATA PARCEL ID:R04300-003-025-000, R04300-003-057-000, R04300-003-026-010 CURRENT ZONING:R-5 (Z25-06) PROJECT ADDRESS:6425, 6437 GORDON RD. & 1927 GORDON ACRES DR. WILMINGTON, NC 28411 CURRENT OWNER:HERON COVE DEVELOPMENT, LLC PO BOX 538 WRIGHTSVILLE BEACH, NC 28480 TOTAL ACREAGE IN PROJECT BOUNDARY:“6) “$& HERON COVE 6425, 6437 GORDON RD. & 1927 GORDON ACRES DR WILMINGTON, NORTH CAROLINA CIVIL ENGINEER INTRACOASTAL ENGINEERING, PLLC 5725 OLEANDER DR. SUITE E-7 WILMINGTON, NC 28403 PHONE: 910-859-8983 CONTACT: CHARLES CAZIER SURVEYOR BATEMAN CIVIL SURVEY COMPANY 30 COVIL AVE. WILMINGTON, NC 28403 PHONE: 910-772-9113 CONTACT: CARL CORPUS CLIENT HERON COVE DEVELOPMENT, LLC PO BOX 538 WRIGHTSVILLE BEACH, NC 28480 PHONE: 910-399-5688 CONTACT: CRAIG JOHNSON SHEET NO.DESCRIPTION C-0 EXISTING CONDITIONS, DEMO & TREE REMOVAL PLAN C-1 SITE, GRADING, DRAINAGE & STORMWATER PLAN C-2 UTILITIES PLAN C-3 SEDIMENTATION & EROSION CONTROL PLAN C-4 SANITARY SEWER PLAN/PROFILE C-5 SANITARY SEWER PLAN/PROFILE C-6 GENERAL DETAILS C-7 STORMWATER DETAILS C-8 SEDIMENTATION & EROSION CONTROL DETAILS C-9 NCDOT DETAILS C-10 UTILITY DETAILS C-11 UTILITY DETAILS C-12 NCG01 NOTES VICINITY MAP (NOT TO SCALE): GO R D O N R D . SITE GO R D O N A C R E S D R . DA N I E L B O O N E T R L . DA I S Y L E E D R . M I L I T A R Y C U T O F F E X T . MIS S I O N H I L L S D R . PA T S Y L N . OG D E N P A R K D R . 200'100'50'100'0' Scale: 1"=100' 40 4 0 35 35 35 35 35 35 35 3535 40 40 30' P.U.E. 6ƒ ( 24.90' MA T C H L I N E WETLAND AREA FLAGGED BY SOUTHERN ENVIRONMENTAL GROUP 30' A.E. TO BE ABANDONED MB 35, PG 9 41 36 40 41 39 38 37 36 37 38 38 37 39 37 36 MA T C H L I N E APPROX. LOCATION EX. 8" SEWER MAIN NC GR I D N A D 8 3 ( N S R S 2 0 1 1 ) 4343 43 43 43 42 42 42 43 43 43 43 43 43 43 43 43 43 43 43 42 43 43 43 41 C-0 1 EX I S T I N G C O N D I T I O N S , DE M O L I T I O N & T R E E R E M O V A L PL A N 1" = 60' REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: CLIENT INFORMATION: VICINITY MAP (NOT TO SCALE): 2025-009 CLIENT INFORMATION: +HURQ&RYH'HYHORSPHQW//& PO Box 538 Wrightsville Beach, NC 28480 Ph. 910-399-5688 OF 13 JAE CDC CDC 24x36 9/29/2025 PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N GO R D O N R D . SITE GOR D O N A C R E S D R . DA N I E L B O O N E T R L . DAI S Y L E E D R . M I L I T A R Y C U T O F F E X T . MIS S I O N H I L L S D R . PAT S Y L N . OG D E N P A R K D R . GO R D O N R D . SITE GOR D O N A C R E S D R . DAN I E L B O O N E T R L . DAI S Y L E E D R . M I L I T A R Y C U T O F F E X T . MIS S I O N H I L L S D R . PA T S Y L N . OG D E N P A R K D R . PROPERTY LINE ADJOINERS LIMITS OF DISTURBANCE 3:1 GRASSED SWALE TREE PROTECTION FENCING SIGNIFICANT TREES TO BE REMOVED PROPOSED DEMOLITION AREA LEGEND SITE DATA PARCEL ID:R04300-003-025-000, R04300-003-057-000, R04300-003-026-010 CURRENT ZONING:R-5 (Z25-06) PROJECT ADDRESS:6425, 6437 GORDON RD. & 1927 GORDON ACRES DR. WILMINGTON, NC 28411 CURRENT OWNER:HERON COVE DEVELOPMENT, LLC PO BOX 538 WRIGHTSVILLE BEACH, NC 28480 TOTAL ACREAGE IN PROJECT BOUNDARY:“6) “$& EXISTING IMPERVIOUS AREAS: (ALL TO BE REMOVED) BUILDINGS:4,500 S.F. SOILS TYPE:Be (Baymeade fine sand) Se (Seagate fine sand) Jo (Johnson soils) Mu (Murrville fine sand) TREE PRESERVATION NOTES: 1.PRIOR TO ANY CLEARING, GRADING, OR CONSTRUCTION ACTIVITY, APPROVED TREE PROTECTION FENCING, SUCH AS SAFETY BARRIER FENCING, A WOODEN SLAT SNOW FENCE OR WIRE FENCE, SHALL BE INSTALLED AROUND PROTECTED TREES OR TREE STANDS LOCATED IN CONSTRUCTION AREAS OR OTHER SITE AREAS THAT WILL BE DISTURBED BY CONSTRUCTION ACTIVITIES. THE FENCING SHALL BE A MINIMUM OF FOUR FEET IN HEIGHT AND BE OF DURABLE CONSTRUCTION. TREE PROTECTIVE FENCING SHALL REMAIN IN PLACE THROUGH COMPLETION OF CONSTRUCTION ACTIVITIES. 2. NO CONSTRUCTION WORKERS, TOOLS, MATERIALS, OR VEHICLES ARE PERMITTED WITHIN THE TREE PROTECTION FENCING. 3.IF AN EXISTING TREE RETAINED TO COMPLY WITH THE STANDARDS OF THIS SECTION IS DESTROYED, SUBSTANTIALLY DAMAGED, OR DIES AS A RESULT OF NEGLIGENCE ON THE PART OF THE PROPERTY OWNER WITHIN THREE YEARS AFTER COMPLETION OF CONSTRUCTION, THEN REPLACEMENT TREES SHALL BE PLANTED ON THE SITE WITH A TOTAL DIAMETER EQUAL TO TWICE THE DIAMETER OF THE RETAINED TREE. A MINIMUM GROWING AREA OF 144 SQUARE FEET SHALL BE PROVIDED FOR EACH REPLACEMENT TREE. IF THE PLANNING DIRECTOR DETERMINES IT IS INFEASIBLE OR FOR REPLACEMENT TREE(S) TO BE ACCOMMODATED ON THE SITE, THEN A PAYMENT MAY BE MADE TO THE &2817<¶675((,03529(0(17)81'(48,9$/(17727+(35,&,1*67$1'$5'6,17+(&2817<)(( SCHEDULE. 120'60'30'60'0' Scale: 1"=60' SITE NOTES: 1.EXISTING SURVEY DATA PROVIDED BY BATEMAN CIVIL SURVEY COMPANY. 2.THESE LOTS ARE LOCATED IN ZONE "X" PER FRIS ON FIRM MAP NUMBER 3720314900K DATED: 08/28/2018 & 3720315900J DATED: 04/03/2006. 3.WETLANDS SHOWN PER SURVEYED FLAGS PLACED BY SOUTHERN ENVIRONMENTAL GROUP, INC. (SEGI) 2/21/2025. 4.$//(/(9$7,2166+2:1+(5(21%$6('219(57,&$/'$7801$9'µ 5.$//+25,=217$/',67$1&(66+2:1+(5(21%$6('211$'¶ 1656 6.THE LOCATION UTILITIES SHOWN HEREON ARE FROM OBSERVED EVIDENCE OF ABOVE GROUND APPURTENANCES ONLY. THE SURVEYOR WAS NOT PROVIDED WITH UNDERGROUND PLANS OR SURFACE GROUND MARKINGS TO DETERMINE THE LOCATION OF SUBTERRANEAN USES. 7.PROPERTY IS SUBJECT TO ANY AND ALL EASEMENTS, RESTRICTIVE COVENANTS, RIGHT OF WAYS OF RECORD, GOVERNMENTAL ORDINANCES AND/OR REQUIREMENTS WHICH MAY LIMIT THE USE OF THIS PROPERTY; WHETHER SHOWN OR NOT SHOWN ON THIS SURVEY. * DEVELOPER IS REQUIRED TO MITIGATE REMOVAL OF SIGNIFICANT TREES NOT LOCATED ON SINGLE FAMILY LOTS. MITIGATION REQUIRED FOR REMOVAL OF SIGNIFICANT TREES FOR ESSENTIAL SITE IMPROVEMENTS QTY SIZE TYPE REPLACEMENT INCHES 1 36"PINE 72.00 1 30"LOBLOLLY 60.00 1 28"LOBLOLLY 56.00 1 24"LOBLOLLY 48.00 3 18"LONGLEAF 108.00 1 30"MAPLE 60.00 1 26"MAPLE 52.00 3 18"MAPLE 108.00 1 30"OAK 60.00 1 28"OAK 56.00 1 20"OAK 40.00 2 18"OAK 72.00 1 18"MAGNOLIA 36.00 2 10"MAGNOLIA 40.00 2 8"MAGNOLIA 32.00 TOTAL REPLACEMENT INCHES 900 40 40 35 35 35 35 35 35 35 35 35 3535 40 40 30' P.U.E. MA T C H L I N E 30' PROP. P.D.E. 63 ' 4 4 CLUSTER MAILBOX (DESIGN BY OTHERS) 2 18" FES INV: 33.5 18" FES INV: 32.5 18" RCP CI#8 RIM: 39.25 INV: 36.0 AP P R O X . L O C A T I O N E X . W A T E R M A I N 38.0 18 " R C P HERON COVE DRIVE PROP. 45' PRIVATE R.O.W. & PUBLIC U.E. 38.5 40.5 1 8 " R C P NCDOT HEADWALL W/ 20' X 25' X 24" RIP-RAP LINED ENTRANCE 10' M.U.P. 37.4 38.520 ' 87' R 3 5 ' R35' MATCH EX. ASPHALT “ 37.1 CI#5 RIM: 37.25 INV: 34.15 CI#10 RIM: 37.25 INV: 33.2 27.5 WETLAND AREA FLAGGED BY SOUTHERN ENVIRONMENTAL GROUP 50 ' 50 ' 41.0 18 " R C P 24" RCP 43 41 3640 41 39 38 37 36 37 38 38 37 39 37 36 20' PERIPHERY SETBACK (TYP) 20' PERIPHERY SETBACK (TYP) 24" FES W/6'X10'X12" ED INV: 33.0 CI#4 RIM: 37.0 INV: 33.9 CI#3 RIM: 37.0 INV: 34.35 41.5 41.0 CI#1 RIM: 37.0 INV: 34.4 CI#2 RIM: 37.0 INV: 34.20 41.65 41.65 (60' PRIVATE R/W) SIREN ACTIVATED GATE AT BOUNDARY MA T C H L I N E 63 ' 4 9' 18' 4 4 CLUSTER MAILBOX (DESIGN BY OTHERS) CI#8 RIM: 39.25 INV: 36.0 CI#12 RIM: 40.0 INV: 37.15 CI#13 RIM: 40.25 INV: 37.5 24" RCP 30" RCP 42.0 10' PROP. PEDESTRIAN ACCESS & UTILITY EASEMENT 30" RCP 42.25 APPROX. LOCATION EX. 8" SEWER MAIN NC G R I D N A D 8 3 ( N S R S 2 0 1 1 ) 41.0 HERON COVE DRIVE PROP. 45' PRIVATE R.O.W. & PUBLIC U.E. 4343 43 43 43 42 42 42 43 43 43 43 43 43 43 43 43 43 43 43 42 43 43 43 41 20' PERIPHERY SETBACK (TYP) CI#17 RIM: 41.25 INV: 35.4CI#16 RIM: 40.25 15" INV. IN: 37.4 INV: 36.15 41.5 41.5 41.0 42.0 41.5 41.65 41.65 C-1 2 1" = 60' REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: CLIENT INFORMATION: VICINITY MAP (NOT TO SCALE): 2025-009 CLIENT INFORMATION: +HURQ&RYH'HYHORSPHQW//& PO Box 538 Wrightsville Beach, NC 28480 Ph. 910-399-5688 OF 13 JAE CDC CDC 24x36 9/29/2025 PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N GO R D O N R D . GO R D O N A C R E S D R . DAN I E L B O O N E T R L . DAI S Y L E E D R . M I L I T A R Y C U T O F F E X T . MIS S I O N H I L L S D R . PAT S Y L N . OG D E N P A R K D R . GO R D O N R D . SITE GO R D O N A C R E S D R . DAN I E L B O O N E T R L . DAI S Y L E E D R . M I L I T A R Y C U T O F F E X T . MIS S I O N H I L L S D R . PAT S Y L N . OG D E N P A R K D R . PE R F O R M A N C E R E S I D E N T I A L GR A D I N G , D R A I N A G E , & S I T E PL A N PROPERTY LINE RIGHT OF WAY ADJOINERS PROPOSED LOTLINE EX. EDGE OF PAVEMENT PROPOSED OPEN SPACE FLOW DIRECTION PROPOSED SPOT ELEVATION LEGEND SITE DATA PARCEL ID:R04300-003-025-000, R04300-003-057-000, R04300-003-026-010 CURRENT ZONING:R-5 (Z25-06) PROJECT ADDRESS:6425, 6437 GORDON RD. & 1927 GORDON ACRES DR. WILMINGTON, NC 28411 CURRENT OWNER:HERON COVE DEVELOPMENT, LLC PO BOX 538 WRIGHTSVILLE BEACH, NC 28480 TOTAL ACREAGE IN PROJECT BOUNDARY:“6) “$& MAXIMUM DENSITY:8 D.U./ACRE (8 X 10.87=87 D.U. ALLOWED) PROPOSED UNITS:67 LOTS MAXIMUM BUILDING HEIGHT:40' REQUIRED PERIMETER SETBACK:20' TOTAL OPEN SPACE REQUIREMENT: (20% OF SITE AREA) REQUIRED 10.87 AC. X 20%= 2.17 AC PROVIDED:3.25 AC ON-SITE IMPERVIOUS AREAS: 67 LOTS 120,600 S.F. (1,800 S.F. Per Lot) FUTURE OUTPARCEL 13,200 S.F. ASPHALT ROAD 53,900 S.F. CONCRETE SIDEWALK, C&G, ETC. 31,670 S.F. FUTURE (RECREATION AREA) 8,540 S.F. TOTAL 227,910 S.F. (48.13%) PROPOSED SEWER AND WATER DEMAND: SEWER: (67) 3 BDRM RES. @ 225 GAL/RES. = 15,075 GPD WATER: (67) 3 BDRM RES. @ 400 GAL/RES. = 26,800 GPD ESTIMATED TRIP GENERATION (Per Trip Generation Manual): 67 RESIDENTIAL D.U. (ITE CODE 210) AM PEAK: 47 PM PEAK: 63 120'60'30'60'0' Scale: 1"=60' 42.0 FIRE & SAFETY NOTES: 1.PARKING AND LANDSCAPING CANNOT BLOCK FIRE HYDRANTS. 2.ALL WEATHER ACCESS ROAD MUST BE MAINTAINED AROUND CONSTRUCTION SITE AT ALL TIMES. 3.ALL FIRE HYDRANTS MUST BE INSTALLED WITH 5 INCH STORZ QUICK CONNECTS ON A 4.5 INCH STEAMER IN COMPLIANCE WITH NHC FIRE SERVICE REQUIREMENTS. CZD CONDITIONS (Z25-06): 1.THE PROJECT WILL INCLUDE EMERGENCY ONLY ACCESS TO DANIEL BOONE TRAIL. 2.THE PROJECT WILL INCLUDE A MINIMUM OF ONE-CAR GARAGE WITH EACH HOME AND ABILITY TO PARK TWO CARS IN THE DRIVEWAY OF EACH HOME. 3.THE PROJECT WILL PROVIDE A SIX-FOOT FENCE AT THE REAR OF EACH LOT IN THE DEVELOPMENT. 4.TWO TREES AT LEAST 2 INCHES IN DIAMETER AT BREAST HEIGHT WILL BE PLANTED ON EACH LOT, TO BE MAINTAINED BY THE HOA THROUGH A LANDSCAPING EASEMENT ON EACH LOT. TREE MAINTENANCE AND PRESERVATION WILL BE INCLUDED IN THE COVENANTS WHICH ARE SUBJECT TO COUNTY REVIEW BEFORE RECORDING OF FINAL PLAT. 5.THE 18-INCH OAK TREE IN THE MIDDLE OF THE INTERNAL ROAD, AROUND WHICH THE ROAD HAS BEEN RECONFIGURED, WILL BE PRESERVED ON THE SITE. 6.THERE WILL BE TWO 10-FOOT IN WIDTH BICYCLE AND PEDESTRIAN ACCESS EASEMENTS IN THIS DEVELOPMENT, CONNECTING DANIEL BOONE TRAIL AND GORDON ACRES DRIVE. 7.A PUBLIC UTILITY EASEMENT MEETING THE MINIMUM STANDARDS OF CFPUA FOR WATER AND SEWER INFRASTRUCTURE SHALL BE DEDICATED ALONG THE BICYCLE AND PEDESTRIAN EASEMENT CONNECTION TO GORDON ACRES DRIVE AT THE TIME THE FINAL PLAT IS RECORDED WITH THE REGISTER OF DEEDS. 8.EXISTING TREES IN THE SITE'S OPEN SPACE THAT DO NOT IMPACT REQUIRED LAND GRADING OR OTHER IMPROVEMENTS AND FUTURE AMENITIES AS IDENTIFIED IN THE REQUIRED TREE REMOVAL PERMIT WILL BE PRESERVED. 9.MAINTENANCE OF THE FENCE REQUIRED IN CONDITION #3 ABOVE WILL BE THE RESPONSIBILITY OF THE PROPERTY OWNER AND INCLUDED IN THE HOMEOWNER'S ASSOCIATION COVENANTS, TO BE RECORDED WITH THE FINAL PLAT WITH THE NEW HANOVER COUNTY REGISTER OF DEEDS. THE PLAT WILL NOTE THAT THIS STUDY IS NON-REGULATORY. 10.THE 2025 NEW HANOVER COUNTY FLOODPLAIN ADVISORY STUDY SHALL BE SHOWN ON THE FINAL PLAT FOR THIS DEVELOPMENT, NOTING ON LOTS 7 & 59 THE FLOOD RISK AS PART OF THAT STUDY, AND SHALL BE RECORDED WITH THE FINAL PLAN WITH THE NEW HANOVER COUNTY REGISTER OF DEEDS. THE PLAT WILL NOTE THAT THIS STUDY IS NON-REGULATORY. DEVELOPMENT NOTES: 1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH THE NEW HANOVER COUNTY UNIFIED DEVELOPMENT ORDINANCE 2. PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS. 3. RUNOFF FROM ALL IMPERVIOUS SURFACES TO BE DIRECTED TO STORMWATER FACILITY 4. MIN. 10' SEPARATION BETWEEN BUILDINGS REQUIRED FOR PERFORMANCE RESIDENTIAL. 5. PROPOSED STREET TO MEET NEW HANOVER COUNTY SUBDIVISION ORDINANCE MINIMUM STANDARDS FOR PRIVATE STREETS. 6. DEVELOPER IS RESPONSIBLE FOR STREET SIGN AND STREET LIGHTING INSTALLATION IN ACCORDANCE WITH NEW HANOVER COUNTY SUBDIVISION ORDINANCE. 7. ALL OPEN SPACES, COMMON AREAS, PRIVATE ROW'S, EASEMENTS, AND DRAINAGE POND AREAS TO BE MAINTAINED BY THE DEVELOPER UNTIL THEY'RE TURNED OVER TO THE HOME OWNERS ASSOCIATION. 8.DEVELOPER TO PROVIDE MAILBOX KIOSK AND PAD IN OPEN SPACE AREA. 9.DEVELOPER TO PROVIDE ONE FRONT YARD AND ONE BACKYARD TREE FOR EACH LOT AND PROTECTED PER DEED RESTRICTIONS. A 5' FRONT AND REAR LANDSCAPE EASEMENT TO BE PROVIDED ON EACH LOT FOR THIS PROVISION. UTILITY NOTES: 1.EXISTING WATER AND SANITARY SEWER SERVICES ARE CURRENTLY AVAILABLE TO THE SITE FROM CAPE FEAR PUBLIC UTILITY AUTHORITY PUBLIC MAINS. 2.ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS & TELEPHONE SHALL BE INSTALLED UNDERGROUND. 3.ALL WATER & SEWER UTILITIES TO BE INSTALLED PER CFPUA TECHNICAL SPECIFICATIONS & STANDARDS. 4.PROJECT SHALL COMPLY WITH CFPUA CROSS CONNECTION CONTROL REQUIREMENTS. WATER METER(S) CANNOT BE RELEASED UNTIL ALL REQUIREMENTS ARE MET AND N.C.D.E.N.R. HAS ISSUED THEIR "FINAL APPROVAL.". CALL 332-6558 FOR INFORMATION. 5.ANY BACKFLOW PREVENTION DEVICES REQUIRED BY THE CFPUA WILL NEED TO BE ON THE LIST OF APPROVED DEVICES BY USCFCCCHR OR ASSE. 6.IF CONTRACTOR DESIRES CFPUA WATER FOR CONSTRUCTION, HE SHALL APPLY IN ADVANCE FOR THIS SERVICE AND MUST PROVIDE A REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTION DEVICE ON THE DEVELOPER'S SIDE OF THE WATER METER BOX. 7.WHEN PVC WATER MAINS AND SERVICES ARE PROPOSED, THE PIPES ARE TO BE MARKED WITH NO. 10 INSULATED, SINGLE-STRAND COPPER WIRE INSTALLED & STRAPPED TO THE PIPES WITH DUCT TAPE. THIS IS TO BE ACCESSIBLE IN ALL VALVES AND METER BOXES TO AID IN FUTURE LOCATION OF FACILITIES. 8.SEWER GUARDS REQUIRED AT ALL MANHOLES. STAINLESS STEEL SEWER GUARDS REQUIRED AT MANHOLES LOCATED IN TRAFFIC AREAS. 9.SERVICES SHALL BE PERPENDICULAR TO MAIN AND TERMINATE AT RIGHT-OF-WAY LINE. SERVICES IN CUL-DE-SACS ARE REQUIRED TO BE PERPENDICULAR OR MUST ORIGINATE IN MANHOLE AND TERMINATE AT RIGHT-OF-WAY LINE. 10. ALL SERVICES TYING INTO DUCTILE IRON MAINS SHALL BE CONSTRUCTED OF CLASS 50 D.I.P. WITH PROTECTO 401 CERAMIC EPOXY LINING. 11.MINIMUM 10' UTILITIES EASEMENT PROVIDED ALONG THE FRONTAGE OF ALL LOTS AND AS SHOWN FOR NEW DEVELOPMENTS. 12.NO FLEXIBLE COUPLINGS SHALL BE USED. 13.ALL STAINLESS STEEL FASTENERS SHALL BE 316. 14.THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIES DURING CONSTRUCTION. CALL NC811 AT 811 OR 1-800-632-4949. CONTRACTOR IS RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ANY UTILITIES, CURB & GUTTER, PAVEMENT, ETC. THAT MAY BE BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIRED TO AT LEAST THE QUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM. 14.SHOULD ADDITIONAL SERVICES BE LOCATED DURING CONSTRUCTION, THEY MUST EITHER BE UTILIZED OR ABANDONED. 40 40 35 35 35 35 35 35 35 35 35 3535 40 40 30' P.U.E. AP P R O X . L O C A T I O N E X . S S M A I N MA T C H L I N E CLUSTER MAILBOX (DESIGN BY OTHERS) AP P R O X . L O C A T I O N E X . W A T E R M A I N HERON COVE DRIVE PROP. 45' PRIVATE R.O.W. & PUBLIC U.E. SSMH #2B SSMH #1B 8" SS MAIN 8" S S M A I N 10' M.U.P. 27.5 WETLAND AREA FLAGGED BY SOUTHERN ENVIRONMENTAL GROUP 8" SS MAINSSMH #2A 43 41 3640 41 39 38 37 36 37 38 38 37 39 37 36 8" SS MAIN SSMH #1C MA T C H L I N E CLUSTER MAILBOX (DESIGN BY OTHERS) APPROX. LOCATION EX. 8" SEWER MAIN TIE TO EX. 6" WATER MAIN (1) 6" CUT-IN TEE (1) 6" X 8" INCREASER (1) 8" G.V. (1) 8" TEE (2) 8" G.V. 8" C-900 PVC W. MAIN (36" MIN. BURY) NC G R I D N A D 8 3 ( N S R S 2 0 1 1 ) HERON COVE DRIVE PROP. 45' PRIVATE R.O.W. & PUBLIC U.E. 4343 43 43 43 42 42 42 43 43 43 43 43 43 43 43 43 43 43 43 42 43 43 43 41 SSMH #1C C-2 3 1" = 60' REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: CLIENT INFORMATION: VICINITY MAP (NOT TO SCALE): 2025-009 CLIENT INFORMATION: +HURQ&RYH'HYHORSPHQW//& PO Box 538 Wrightsville Beach, NC 28480 Ph. 910-399-5688 OF 13 JAE CDC CDC 24x36 9/29/2025 PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N GO R D O N R D . GO R D O N A C R E S D R . DAN I E L B O O N E T R L . DAI S Y L E E D R . M I L I T A R Y C U T O F F E X T . MIS S I O N H I L L S D R . PAT S Y L N . OG D E N P A R K D R . GO R D O N R D . SITE GO R D O N A C R E S D R . DAN I E L B O O N E T R L . DAI S Y L E E D R . M I L I T A R Y C U T O F F E X T . MIS S I O N H I L L S D R . PAT S Y L N . OG D E N P A R K D R . PROPERTY LINE RIGHT OF WAY ADJOINERS PROPOSED LOTLINE EX. EOP PROP. EASEMENT CENTER LINE WATERLINE SANITARY SEWER LINE FIRE HYDRANT ASSY SAMPLING STATION GATE VALVE LEGEND PE R F O R M A N C E R E S I D E N T I A L UT I L I T I E S P L A N SITE DATA PARCEL ID:R04300-003-025-000, R04300-003-057-000, R04300-003-026-010 CURRENT ZONING:R-5 (Z25-06) PROJECT ADDRESS:6425, 6437 GORDON RD. & 1927 GORDON ACRES DR. WILMINGTON, NC 28411 CURRENT OWNER:HERON COVE DEVELOPMENT, LLC PO BOX 538 WRIGHTSVILLE BEACH, NC 28480 TOTAL ACREAGE IN PROJECT BOUNDARY:“6) “$& MAXIMUM DENSITY:8 D.U./ACRE (8 X 10.87=87 D.U. ALLOWED) PROPOSED UNITS:67 LOTS PROPOSED SEWER AND WATER DEMAND: SEWER: (67) 3 BDRM RES. @ 225 GAL/RES. = 15,075 GPD WATER: (67) 3 BDRM RES. @ 400 GAL/RES. = 26,800 GPD 120'60'30'60'0' Scale: 1"=60' UTILITY NOTES: 1.EXISTING WATER AND SANITARY SEWER SERVICES ARE CURRENTLY AVAILABLE TO THE SITE FROM CAPE FEAR PUBLIC UTILITY AUTHORITY PUBLIC MAINS. 2.ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS & TELEPHONE SHALL BE INSTALLED UNDERGROUND. 3.ALL WATER & SEWER UTILITIES TO BE INSTALLED PER CFPUA TECHNICAL SPECIFICATIONS & STANDARDS. 4.PROJECT SHALL COMPLY WITH CFPUA CROSS CONNECTION CONTROL REQUIREMENTS. WATER METER(S) CANNOT BE RELEASED UNTIL ALL REQUIREMENTS ARE MET AND N.C.D.E.N.R. HAS ISSUED THEIR "FINAL APPROVAL.". CALL 332-6558 FOR INFORMATION. 5.ANY BACKFLOW PREVENTION DEVICES REQUIRED BY THE CFPUA WILL NEED TO BE ON THE LIST OF APPROVED DEVICES BY USCFCCCHR OR ASSE. 6.IF CONTRACTOR DESIRES CFPUA WATER FOR CONSTRUCTION, HE SHALL APPLY IN ADVANCE FOR THIS SERVICE AND MUST PROVIDE A REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTION DEVICE ON THE DEVELOPER'S SIDE OF THE WATER METER BOX. 7.WHEN PVC WATER MAINS AND SERVICES ARE PROPOSED, THE PIPES ARE TO BE MARKED WITH NO. 10 INSULATED, SINGLE-STRAND COPPER WIRE INSTALLED & STRAPPED TO THE PIPES WITH DUCT TAPE. THIS IS TO BE ACCESSIBLE IN ALL VALVES AND METER BOXES TO AID IN FUTURE LOCATION OF FACILITIES. 8.SEWER GUARDS REQUIRED AT ALL MANHOLES. STAINLESS STEEL SEWER GUARDS REQUIRED AT MANHOLES LOCATED IN TRAFFIC AREAS. 9.SERVICES SHALL BE PERPENDICULAR TO MAIN AND TERMINATE AT RIGHT-OF-WAY LINE. SERVICES IN CUL-DE-SACS ARE REQUIRED TO BE PERPENDICULAR OR MUST ORIGINATE IN MANHOLE AND TERMINATE AT RIGHT-OF-WAY LINE. 10. ALL SERVICES TYING INTO DUCTILE IRON MAINS SHALL BE CONSTRUCTED OF CLASS 50 D.I.P. WITH PROTECTO 401 CERAMIC EPOXY LINING. 11.MINIMUM 10' UTILITIES EASEMENT PROVIDED ALONG THE FRONTAGE OF ALL LOTS AND AS SHOWN FOR NEW DEVELOPMENTS. 12.NO FLEXIBLE COUPLINGS SHALL BE USED. 13.ALL STAINLESS STEEL FASTENERS SHALL BE 316. 14.THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIES DURING CONSTRUCTION. CALL NC811 AT 811 OR 1-800-632-4949. CONTRACTOR IS RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ANY UTILITIES, CURB & GUTTER, PAVEMENT, ETC. THAT MAY BE BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIRED TO AT LEAST THE QUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM. 14.SHOULD ADDITIONAL SERVICES BE LOCATED DURING CONSTRUCTION, THEY MUST EITHER BE UTILIZED OR ABANDONED. C-6 7 DE T A I L S NTS REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: CLIENT INFORMATION: VICINITY MAP (NOT TO SCALE): 2025-009 CLIENT INFORMATION: +HURQ&RYH'HYHORSPHQW//& PO Box 538 Wrightsville Beach, NC 28480 Ph. 910-399-5688 OF 13 JAE CDC CDC 24x36 9/29/2025 PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N GO R D O N R D . SITE GO R D O N A C R E S D R . DAN I E L B O O N E T R L . DAI S Y L E E D R . M I L I T A R Y C U T O F F E X T . MIS S I O N H I L L S D R . PAT S Y L N . OG D E N P A R K D R . GO R D O N R D . SITE GOR D O N A C R E S D R . DAN I E L B O O N E T R L . DAI S Y L E E D R . M I L I T A R Y C U T O F F E X T . MIS S I O N H I L L S D R . PAT S Y L N . OG D E N P A R K D R . 12" 6. 5 " 8" ABC STONE BASE 7" 24" 12" 11 " NTS VALLEY CURB DETAIL NOTES: 1. EXPANSION JOINT MATERIAL TO COMPLY WITH CURRENT NCDOT STANDARDS 2. 50' MAX EXPANSION JOINT SPACING, 10' MAX CONTRACTION JOINT SPACING 3. MINIMUM INSTALLATION LENGTH IS 5 FT. 4. CONCRETE TO BE 3000 PSI MIN SITE WORK NOTES: 1.THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS BOTH ON AND ADJACENT TO THE SITE. 2.CLEARING: CONTRACTOR SHALL REMOVE ALL TREES AND VEGETATION WITHIN LIMITS OF CONSTRUCTION UNLESS OTHERWISE DESIGNATED TO REMAIN. 3.GRUBBING AND STRIPPING: CONTRACTOR SHALL RAKE AND REMOVE ROOTS, STUMPS, VEGETATION, DEBRIS, EXISTING STRUCTURES ABOVE AND BELOW GRADE, ORGANIC MATERIAL OR ANY OTHER UNSUITABLE MATERIAL WITHIN LIMITS OF CONSTRUCTION. 4.MUCKING: CONTRACTOR SHALL COORDINATE WITH OWNER AND THEIR GEOTECHNICAL REPRESENTATIVE TO COORDINATE REMOVAL OF ANY SOFT AREAS. 5.DISPOSAL: CLEARED, GRUBBED, STRIPPED OR OTHER WASTE MATERIAL SHALL BE REMOVED FROM SITE AND DISPOSED OF IN A PROPERLY PERMITTED FACILITY. 6.FILL AND COMPACTION SHOULD COMPLY WITH GEOTECHNICAL RECOMMENDATIONS. 7.THE CONTRACTOR SHALL NOTE THAT THE GRADING PLAN MAY NOT REPRESENT A BALANCED EARTHWORK CONDITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CUT AND FILL QUANTITIES AND COMPLETE INSTALLATION TO SPECIFIED GRADES. 8.THE CONTRACTOR SHALL FURNISH SUITABLE BORROW MATERIAL FROM AN OFF-SITE PROPERLY PERMITTED FACILITY AS REQUIRED. 9.INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXACT ELEVATIONS AND LOCATIONS OF ALL EXISTING UTILITIES AT ALL CROSSINGS PRIOR TO COMMENCING TRENCH EXCAVATION. IF ACTUAL CLEARANCES ARE LESS THAN INDICATED ON PLAN, THE CONTRACTOR SHALL CONTACT THE DESIGN ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. ANY CONDITION DISCOVERED OR EXISTING THAT WOULD NECESSITATE A MODIFICATION OF THESE PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. 10.NO CONSTRUCTION IS TO BEGIN BEFORE LOCATION OF EXISTING UTILITIES HAS BEEN DETERMINED. CALL "NC ONE-CALL" AT LEAST 48 HOURS BEFORE COMMENCING CONSTRUCTION. 11.THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES DURING CONSTRUCTION. BEFORE COMMENCING ANY EXCAVATIONS IN OR ALONG ROADWAYS OR RIGHT-OF-WAYS, PUBLIC AREAS OR IN PRIVATE EASEMENTS, THE CONTRACTOR SHALL NOTIFY ALL APPROPRIATE PERSONNEL OF THEIR INTENT TO EXCAVATE, IN WRITING, NOT LESS THAN 10 DAYS PRIOR TO EXCAVATING. 12.THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE DISCONNECTION/ RECONNECTION AND/OR THE RELOCATION OF ALL EXISTING UTILITIES WITH APPROPRIATE PERSONNEL. 13.CONTRACTOR SHALL ADJUST ALL MANHOLES, VALVE & CURB BOXES TO FINAL GRADE UPON COMPLETION OF ALL CONSTRUCTION. ANY BOXES DAMAGED OR OTHERWISE DISTURBED BY THE CONTRACTOR SHALL BE REPAIRED AT THE EXPENSE OF THE CONTRACTOR. 14.THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AT THE SITE. FURTHERMORE THE CONTRACTOR SHALL REPORT ALL DISCREPANCIES OR QUESTIONS TO THE ENGINEER PRIOR TO INSTALLATION. 15.THE CONTRACTOR SHALL PROVIDE ANY AND ALL LAYOUT REQUIRED TO CONSTRUCT HIS WORK UNLESS OTHERWISE DIRECTED BY OWNER. 16.ALL SERVICE CONNECTIONS SHALL BE INSTALLED TO MEET ALL LOCAL, STATE, AND CFPUA CODES. METERS, TAPS, MATERIALS, WORKMANSHIP AND ALL FEES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL COMPLY WITH ALL REQUIREMENTS. 17.ALL BACKFILL FROM UTILITY INSTALLATION MUST BE COMPACTED OR AMENDED TO PROVIDE TRAFFIC BEARING CAPACITY. GEOTECHNICAL ENGINEER TO BE CONSULTED AT CONTRACTORS COST AS NECESSARY. 18.ALL AREAS SHALL BE GRADED FOR POSITIVE DRAINAGE. CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO INSTALLATION. ALL AREAS SHALL BE SLOPED TO DRAIN AWAY FROM BUILDINGS AT ALL TIMES. 19.CONCRETE FOR WALKS, CURBS AND DRIVES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI @ 28 DAYS - AIR ENTRAINED. 20.FIELD TESTING SHALL BE DONE BY AN INDEPENDENT TESTING LABORATORY PAID FOR BY THE OWNER. FURTHER TESTING REQUIRED DUE TO A FAILED TEST WILL BE PAID FOR BY THE CONTRACTOR. 21.ALL SIDEWALKS SHALL BE FREE OF CRACKS, BREAKS, OR ANY OTHER DEFECT PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. 30' FILLED EXPANSION JOINT FILLED EXPANSION JOINT 5' SECTION A-A 5' A A CONTROL JOINT FILLED EXPANSION JOINT 4" 1/2" SECTION B-B SCORE 1/4"1" B B NOTES: 1.JOINT MATERIAL TO COMPLY WITH CURRENT NCDOT STANDARDS. 2.SANITARY SEWER CLEAN-OUTS, WATER METERS, MANHOLES, AND VALVE LIDS TO BE LOCATED OUTSIDE SIDEWALK WHERE FEASIBLE. 3.MINIMUM SIDEWALK WIDTH TO BE 6' MINIMUM IF PLACED AT BACK OF CURB. 4.CONCRETE FOR ALL SIDEWALKS (EXCEPT ANY PORTION CONTAIN WITHIN A DRIVEWAY APRON) SHALL BE CLASS "A" - 3,000 PSI. 5.MINIMUM REPLACEMENT FOR REPAIRS IS A 5' X 5' PANEL 6.4" STONE BASE MAY BE REQUIRED FOR POOR SOIL CONDITIONS 7.MINIMUM DEPTH FOR TUNNELING BELOW SIDEWALK IS 12" 8.MAX ADJACENT GROUND SLOPE WITHOUT RAILING IS 2:1 9.MIN GRADE FOR PROPER DRAINAGE IS 1% IN AT LEAST 1 DIRECTION. MAX CROSS SLOPE IS 2%. MAX LONGITUDINAL SLOPE IS 8.3%, 10% IF LIMITED BY EXISTING CONDITIONS, OR NO GREATER THAN THE SLOPE OF THE EXISTING ADJACENT ROAD. STANDARD SIDEWALK DETAIL NTS EXISTING GORDON ROAD PROPOSED ROAD GRADE 2% MIN SLOPE 6' MIN ROAD TIE-IN GRADING SECTION NTS PROPOSED STREET PROPOSED LOT BACK OF CURB NTS PROPOSED TYPICAL LOT GRADING “ ('*(2) PAVEMENT APPROXIMATE HOUSE FOOTPRINT MIN PAD: B.O.C. +1.0' 0. 3 % M I N 0. 3 % M I N ORANGE SAFETY FENCE OR ORANGE SILT FENCE (TYPICAL) CRZ NOTES: 1.PROTECT CRITICAL ROOT ZONE (CRZ) OF TREES PRIOR TO CONSTRUCTION. CLEARLY MARK THE TREES AND ERECT A PROTECTIVE BARRIER AT THE CRZ. BARRIER SHALL BE MAINTAINED UNTIL CONSTRUCTION IS COMPLETE. 2.CRZ RADIUS IS 1 FT PER INCH OF TREE DIAMETER AT BREAST HEIGHT (DBH). 3.IF CONSTRUCTION OCCURS WITHIN THE CRZ, AT LEAST 12" OF MULCH AND/OR LOGGING MATTS SHALL BE PLACED WHERE MACHINERY MANEUVERS TO REDUCE SOIL COMPACTION IN THIS ZONE. 4.WHERE SIDEWALKS AND PATHWAYS PASS WITHIN CRZ, EXTRA CARE SHALL BE TAKEN TO AVOID DAMAGE TO THE ROOTS. ALTERNATE CONSTRUCTION METHODS, SUCH AS A REINFORCED SIDEWALK, SHALL BE IMPLEMENTED AS NECESSARY. 5.FOR ALL TREES, CUTTING OF LARGE STRUCTURAL ROOTS LOCATED NEAR THE BASE OF THE TRUNK IS PROHIBITED. DO NOT COMPACT SOIL BENEATH TREES. NO VEHICLE SHALL BE ALLOWED TO PARK UNDER TREES. NO MATERIALS OR EQUIPMENT SHALL BE STORED BENEATH TREES. DAMAGING THE BARK WITH LAWNMOWERS, CONSTRUCTION EQUIPMENT, OR ANYTHING ELSE IS PROHIBITED. CONTRACTOR SHALL REPAIR DAMAGE TO TREES. 6.THE CRITICAL ROOT ZONE (CRZ) OF A TREE IS WHERE THE MAJORITY OF A TREE'S ROOTS LAY. 85% OF MOST TREE ROOTS ARE FOUND IN THE TOP 24" OF THE SOIL AND SUPPLY THE MAJORITY OF NUTRIENTS AND WATER. GENERALLY, ROOTS SPREAD OUT 2-3X THE HEIGHT OF THE TREE. 7.CROWN OF THE TREE IS NEEDED FOR LEAF GROWTH TO PRODUCE OXYGEN, FILTER THE AIR, REDUCE WIND AND SOFTEN NOISE. DO NOT DISFIGURE CROWN WITH INTENSIVE PRUNING. 8. THE TREE PROTECTION FENCING SHALL NOT BE VIOLATED FOR THE ENTIRE DURATION OF THE PROJECT WITHOUT APPROVAL FROM URBAN FORESTRY STAFF. 9. WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL. LETTERS TO BE 3" HIGH, MINIMUM, CLEARLY LEGIBLE AND SPACED AS DETAILED. 10. SIGNS SHALL BE PLACED AT 50' MAXIMUM INTERVALS. PLACE A SIGN AT EACH END OF LINEAR TREE PROTECTION AND 50' ON CENTER THEREAFTER. FOR TREE PROTECTION AREAS LESS THAN 100' IN PERIMETER, PROVIDE NO LESS THAN TWO SIGNS PER PROTECTION AREA. 11. ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. MAINTAIN TREE PROTECTION FENCE AND SIGNS THROUGHOUT DURATION OF PROJECT. 12. TREE PROTECTION FENCING AND SIGNAGE SHALL BE REMOVED AFTER CONSTRUCTION. 3' MIN DBH STEEL POST FRONT VIEW SIDE VIEW 40" WARNING SIGN DETAIL 18" VARIABLE AS DIRECTED BY THE ENGINEER 8' MAX. GRADE TREE PROTECTION AREA DO NOT ENTER ORANGE, UV RESISTANT HIGH - TENSILE STRENGTH POLY BARRICADE FABRIC (TYPICAL) ORANGE, UV RESISTANT HIGH - TENSILE STRENGTH POLY BARRICADE FABRIC (TYPICAL) WARNING SIGN PLASTIC OR WIRE TIES WARNING SIGN ZONA PROTECTORA PARA LOS ARBOLES PROHIBIDO ENTRAR TREE PROTECTION AREA DO NOT ENTER ZONA PROTECTORA PARA LOS ARBOLES PROHIBIDO ENTRAR TREE PROTECTION DETAIL NOT TO SCALE WHEEL STOP DETAIL NTS 1. CONTRACTOR SHALL INSTALL PER CITY OF WILMINGTON TECHNICAL STANDARD PER SD 15-13 NOTE: WIDTH x LENGTH x HEIGHT 1/2"1/2"6'-11" FRONT VIEW ‘+2/(6 1/2" END VIEW 4" 4.5" 1/2"8" 9" x 7'-0" x 4" 4000 PSI @ 4 - #4 REBAR 28 DAYS CONCRETE: REINFORCING: PLAN VIEW 12"7'12" 2. CONTRACTOR SHALL INSTALL WHEEL STOP 2.5' FROM SIDEWALK. ASPHALT 2" SF9.5B 8" ABCCURB 24" VALLEY LC 20' 45' PRIVATE RIGHT OF WAY & PUBLIC UTILITY EASEMENT R. O . W . R. O . W . <-- 2.0%<-- 2.0% MAX 5' SIDEWALK PROPOSED STREET SECTION N.T.S. 2.0% --> 5' SIDEWALK 2.0% --> ASPHALT 2" SF9.5B 8" ABCCURB 24" VALLEY LC 12' 63' PRIVATE RIGHT OF WAY & PUBLIC UTILITY EASEMENT R. O . W . <-- 2.0%<-- 2.0% MAX 5' SIDEWALK PROPOSED MEDIAN SECTION N.T.S. 2.0% --> 5' SIDEWALK 2.0% --> 24" C.& G. GRASSED MEDIAN 16' 12'