HomeMy WebLinkAboutCombined Comments - 3008 N Kerr
3008 N Kerr Ave – Flex Space – TRC Review
Page | 1
To: Mark N Hargrove, PE, Port City Engineers, PLLC
From: Katherine May, Development Review Planner
Date: November 5, 2025 Technical Review Committee (TRC)
PID#: R03400-001-028-000
Egov# SITECN-25-000103
Subject: 3008 N Kerr Ave – Flex Space - TRC Review
Technical Review Committee (TRC) General Information
The TRC is a staff-level group of local government officials that reviews projects for compliance with
the local regulations administered by each respective review agency. Voluntarily participating state
agencies may also provide comments. And general information and non-binding recommendations
about the site may also be provided by government agencies.
The TRC meetings are considered staff meetings and are not public hearings. The TRC meeting is an
opportunity for applicants to speak with county staff and any voluntarily participating state or federal
agencies about the review comments they have been provided.
No voting is involved in the TRC process, and no final approvals or denials are made at the TRC
meetings. Following the TRC meeting, applicants are responsible for updating their plans to address
review comments. Those revised plans need to be resubmitted to the assigned case planner. The case
planner will facilitate additional reviews until all comments have been addressed, and the necessary
departments have stated the plans comply with the applicable minimum requirements for
development.
Following any future TRC approval, the project is required to obtain additional permits to include a
zoning compliance permit for the site. Applicants are also responsible for coordinating with state and
federal agencies for compliance with any additional requirements. Any activity on the property that is
not approved as part of the TRC review and zoning compliance permit will be considered a violation
of the UDO and subject to enforcement action under Article 12 Violations and Enforcement.
3008 N Kerr Ave – Flex Space – TRC Review
Page | 2
The following comments have been received for the November 5, 2025, TRC meeting. Additional
comments may be made upon further review of subsequent revisions.
Planning, Katherine May 910-798-7443
Compliance with local UDO requirements
1. General Comments
a. Zoning district – I-2, Heavy Industrial
b. The project is not associated with a rezoning but previously received site plan approval
on March 11, 2021. Due to the lapse in time from the previous approval, the project
must be reviewed again.
c. As stated in the application the intended use is warehousing. The Unified
Development Ordinance (UDO) defines the use as
i. The storing of goods, wares, and merchandise within an enclosed building,
whether for the owners or others. There is little on-site sales activity with the
customer present. Uses include: cold storage facilities (including frozen food
lockers); distribution warehouses (used primarily for temporary storage
pending distribution in response to customer orders); storage warehouses
(used for storage by retail stores such as furniture and appliance stores);
warehouse storerooms; or similar uses.
d. The Planning and Land Use Department’s review of the site is for compliance with the
UDO and use specific requirements of the specified land use. Any other activity that
might occur on the property beyond the definition above should be noted on the
application and site plan for additional review and comment.
e. There does not appear to be Duke Energy Transmission Lines/Easement on the
Property.
2. UDO Section 5.1, Parking and Loading
a. Warehousing requires 1.5 parking spaces for every 1,000 square feet of building area.
Project proposes 7,070 square feet. Required parking is 7,070 / 1,000 = 7.07 x 1.5 =
10.6 required parking spaces. The site plan shows 17 spaces which meets the
minimum required parking.
b. Location of the loading area is missing. Please see 5.1.5.B for the dimensional
standards.
3008 N Kerr Ave – Flex Space – TRC Review
Page | 3
3. UDO Section 5.2, Traffic, Access and Connectivity
a. Please note that no building permit for any structure shall be issued which requires
NCDOT approval for a Driveway Permit until NCDOT has issued the permit approval.
Evidence of approval shall accompany the application for building permit.
b. Include the WMPO’s estimated AM and PM traffic generation. If either AM or PM peak
hour exceeds 100 trips, state a TIA is required.
4. UDO Section 5.3, Tree Retention
a. The site looks to be cleared, please confirm that no trees will be removed.
b. Note: Land disturbance permits can be issued by county Engineering before a Tree
Removal Permit is approved by Planning. However, any trees removed before the Tree
Removal Permit is issued may result in enforcement action under Section 5.3.2 of the
Unified Development Ordinance to include prohibiting any development of the site for
3 to 5 years.
5. UDO Section 5.4, Landscaping and Buffering
a. The project is surrounded by commercial zoning, so no buffers are required.
b. Dumpsters and loading areas must be screened out of view of any public right-of-way.
The plan shows the dumpster is sufficiently screened and the details are included on
page C-7.1.
c. Per table 5.4.5.C: Standards for Parking Lot Interiors
a. Landscaped areas in the interior of parking lots shall be equal to eight percent
of the total area to be used for parking, loading, automobile sales, driveways,
internal drive aisles, and other vehicular or pedestrian use.
b. The landscaped islands meet minimum length requirements
c. At least 75 percent of trees required for interior landscaping shall be of a
shade/canopy species. This requirement has been met.
d. Table 5.4.6.B: Street Yard Area Standards
a. For the I-2 district, 25 square feet for every linear foot of street yard frontage
is required with a minimum of 12.5 feet and a maximum of 37.5 feet. This
requirement has been met.
b. For every 600 square feet of street yard area on average, the following
landscaping shall be provided: One canopy/shade tree or if overhead power
3008 N Kerr Ave – Flex Space – TRC Review
Page | 4
lines are located above the street yard, three (3) understory trees; and Six
shrubs, 12 inches in height at time of planting
i. 2550 sf / 600 sf = 4.25
ii. 3 shade trees and 3 understory trees are provided, which meets the
minimum requirements. The shrubs also meet the minimum
requirements.
6. UDO Section 5.5, Lighting
a. Please note that a lighting plan is not required for TRC approval but will be required
prior to issuance of construction plan approvals.
b. Is any lighting proposed for the site?
7. UDO Section 5.6, Signs
a. I didn’t see any signs proposed, please confirm.
b. For any signs on the site, a separate sign permit must be submitted and reviewed by
the county for compliance with Section 5.6 of the UDO for standards at or after the
submittal of the separate zoning compliance and construction permits for the primary
building or use. Any approvals granted by the TRC for the site design is not an approval
for the ultimate size or placement of the sign.
8. UDO Section 5.7, Conservation Resources
a. The conservation resources map does not indicate any conservation resources
impacting the property, this section does not apply.
9. UDO Article 9, Flood Damage Prevention
a. The property is not in a flood plain.
NHC Fire Services, Ray Griswold 910-798-7448
Compliance with NC Fire Code
1. Fire extinguishers per NFPA 10 2. Fire finals required
NHC Engineering, Galen Jamison 910-798-7072
Stormwater management and land disturbance
1. Please submit for permit revisions to County stormwater permit STMW-20-0043 and land
disturbance permit LNDP-20-00133. Please digitally submit the permit applications
3008 N Kerr Ave – Flex Space – TRC Review
Page | 5
documentation with requisite review fees to the COAST online permit portal
(https://newhanovercountync-energovpub.tylerhost.net/apps/selfservice#/home) using the
referenced permit numbers
2. All conveyance calculations will need to be updated per the latest NHC stormwater design
manual. 3. Please contact the State for their stormwater permit requirements.
NHC Environmental Health, Dustin Fenske 910-798-6732
Septic tanks and wells
1. Site plan reflects connection to public water and sewer. Records reflect the site is
surrounded by parcels that are connected to public water and sewer. No septic or well
issues are apparent for this site design.
NHC Addressing, McCabe Watson 910-798-7068
Street naming and property address
1. Each suite will need its own individual address.
2. Please contact me for address assignment following TRC approval.
Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620
Public water and sewer
1. CFPUA TRC Comments provided are preliminary comments only.
2. CFPUA is moving toward becoming paperless. When ready to submit plan review package,
upload all documents to https://www.cfpua.org/FormCenter/Engineering-3/Engineering-
Plan-Review-103.
3. CFPUA water and sewer available
4. Capacity is dependent on the analysis of the pipe collection system (gravity and force mains)
5. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE
Application Form and a Preliminary Plan, this determination does not guarantee capacity.
6. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the
plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the
Authority.
3008 N Kerr Ave – Flex Space – TRC Review
Page | 6
NCDOT, Nick Drees 910-343-3915
Driveway access and state road improvements
1. See attached comments.
WMPO, Caitlin Cerza 910-473-5130
New Hanover County contracted traffic engineering services comments:
1. See attached comments.
Army Corps of Engineers, Brad Shaver 910-251-4611
Information or Requirements if wetlands are impacted
1. No comments.
Project information also provided to the following state agencies and non-regulatory local
agencies for their awareness:
New Hanover County Emergency Management
New Hanover County Schools
NC Department of Environmental Quality (DEQ)
NC DEQ Division of Coastal Management
NC DEQ Division of Energy, Mineral, and Land Resources
New Hanover County Sustainability Manager
NHC Soil & Water Conservation
MEMORANDUM
To: New Hanover County Technical Review Committee
Date: October 9, 2025
Subject: 3008 N Kerr Avenue Flex Space
Comments:
• N/A
NCDOT Projects:
• N/A
WMPO 2045 MTP Projects:
• N/A
New Hanover County Projects:
• N/A
TIA: Based on the 11th edition ITE Trip Generation Manual, a TIA is not required.
Land Use (ITE Code) Intensity Unit 24 Hour
Volumes
AM Peak
Hour Trips
PM Peak
Hour Trips
Warehousing (150) 9000 Square
Feet 53 25 28
STATE OF NORTH CAROLINA
DEPARTMENT OF TRANSPORTATION
JOSH STEIN DANIEL H. JOHNSON
GOVERNOR SECRETARY
Mailing Address:
NC DEPARTMENT OF TRANSPORTATION
DIVISION OF HIGHWAYS 5911 OLEANDER DRIVE, SUITE 101
WILMINGTON, NC 28403
Telephone: 910-398-9100
Customer Service: 1-877-368-4968
Website: ncdot.gov
Location:
5911 OLEANDER DRIVE, SUIT 101
WILMINGTON, NC 28403
Memorandum
DATE: October 13, 2025
TO: New Hanover County Technical Review Committee
SUBJECT: Flex Space – 3008 North Kerr Avenue
________________________________________________________________________
These are preliminary comments and are based on the plans as submitted for the proposed
site. They are subject to further review upon receipt of any additional information.
Subsequently, additional comments and/or requirements may be necessary for this site.
General Comments:
NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT
Online Portal.https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx
You can coordinate with the District Office with any questions 910-398-9100.
NCDOT Driveway Permit:
A change of ownership can be done for the proposed site.
• Contact Frank Mike for additional details and/or requirements.
NCDOT Encroachment Agreement:
An NCDOT Encroachment Agreement is required for any utility connections or
installations within the NCDOT right-of-way (form 16.6).
• Refer to the NCDOT UAM Manual and the NCDOT encroachment checklist for
required documents and site plan information.
An NCDOT Encroachment Agreement is required for any sidewalk or multi-use paths
installed within the NCDOT right-of-way (form 16.6).
Mailing Address:
NC DEPARTMENT OF TRANSPORTATION
DISTRICT 3 ENGINEER’S OFFICE
5911 OLEANDER DRIVE, SUITE 101
WILMINGTON, NC 28403
Telephone: 910-398-9100
Customer Service: 1-877-368-4968
Website: ncdot.gov
Location:
5911 OLEANDER DRIVE, SUITE 101
WILMINGTON, NC 28403
Site Plan Comments:
Drainage/Stormwater Conveyance:
• If the drainage does not naturally flow to the NCDOT right of way the historic
drainage pattern should be maintained.
NCDOT Standard Drawings:
• Include/update the NCDOT Standard Drawings (2024) that are applicable to the
development.
Sight Triangles and Sight Distance:
• Show and label the 10’ X 70’ NCDOT sight triangles.
o No obstructions shall be placed within the NCDOT sight triangles.
• Show and label the stopping sight distance.
o No obstructions shall be placed within the stopping sight distance.
Identification Signing and Landscaping:
• Identification signing or landscape vegetation within the median and the sight
distance triangle must not obstruct the driver’s line of sight. No landscaping or
signing will be allowed to exceed 42 inches in height, measured from the Edge of
Pavement (EOP) within the median or sight triangle.
• All pylon signs in the median or sight distance triangle must provide a vertical
clear sight zone between 3 feet-6 inches and 10 feet-0 inches measured from the
EOP. Signing located within a clear recovery area shall be of a “breakaway
design.”
• Only low growing shrubbery, consistent with the NCDOT’s landscaping policies,
as contained in the publication “Guidelines for Planting Within Highway Right of
Way,” will be allowed within a landscaped median and the sight distance triangle
at the entranceway to a development, whether the street or driveway connection to
the State Highway System is designated as a public facility or not. Landscaping
within the right-of-way and sight distance triangles may require additional
approval by the District Engineer.
Gated Entrances:
• Show and label any proposed gates with distances to the right of way line.
Site Development For
SEPTEMBER, 2025
WILMINGTON, NORTH CAROLINA
3008 N KERR LLC
11763 ASHTON ROAD
BURGAW, NC 28425
TEL: 910-378-7610
vinceb@burgesscorporation.net
PORT CITY CONSULTING
ENGINEERS, PLLC
6216 STONEBRIDGE ROAD
WILMINGTON, NC 28409
910-599-1744 LICENSE No. P-1032
mhargrove@ec.rr.com
11" OAK
3008 N KERR AVENUE
PRELIMINARY - DO NOT USE FOR CONSTRUCTION
No.
Checked By
Revision Designer
Drawn By
Date By Scale
Date
Job No.
Sheet No.No.
Checked By
Revision Designer
Drawn By
Date By Scale
Date
Job No.NORTH CAROLINANEW HANOVER COUNTY
C-311763 ASHTON ROAD3008 N KERR LLC
BURGAW, NC 28425 SITE PLAN3008 N KERR AVENUE FLEX SPACE PORT CITY CONSULTINGENGINEERS, PLLC6216 STONEBRIDGE ROADWILMINGTON, NC 28409910-599-1744 LICENSE No. P-1032
PRELIMINARY - DO NOT USE FOR CONSTRUCTION
1 inch = 20 ft.
20
GRAPHIC SCALE
01020 40