HomeMy WebLinkAboutCombined Comments - 3419 Castle Hayne Road - Insea Marine Insea Marine – 3419 Castle Hayne Road – TRC Review Page | 1 To: Stephen Conway, Insea Land Acquisitions, LLC From: Katherine May, Development Review Planner Date: November 5, 2025 Technical Review Committee (TRC) PID#: R02511-004-017-000 Egov# SITECN-25-000101 Subject: 3419 Castle Hayne Road– Insea Marine - TRC Review Technical Review Committee (TRC) General Information The TRC is a staff-level group of local government officials that reviews projects for compliance with the local regulations administered by each respective review agency. Voluntarily participating state agencies may also provide comments. And general information and non-binding recommendations about the site may also be provided by government agencies. The TRC meetings are considered staff meetings and are not public hearings. The TRC meeting is an opportunity for applicants to speak with county staff and any voluntarily participating state or federal agencies about the review comments they have been provided. No voting is involved in the TRC process, and no final approvals or denials are made at the TRC meetings. Following the TRC meeting, applicants are responsible for updating their plans to address review comments. Those revised plans need to be resubmitted to the assigned case planner. The case planner will facilitate additional reviews until all comments have been addressed, and the necessary departments have stated the plans comply with the applicable minimum requirements for development. Following any future TRC approval, the project is required to obtain additional permits to include a zoning compliance permit for the site. Applicants are also responsible for coordinating with state and federal agencies for compliance with any additional requirements. Any activity on the property that is not approved as part of the TRC review and zoning compliance permit will be considered a violation of the UDO and subject to enforcement action under Article 12 Violations and Enforcement. The following comments have been received for the November 5th, 2025, TRC meeting. Additional comments may be made upon further review of subsequent revisions. Insea Marine – 3419 Castle Hayne Road – TRC Review Page | 2 Planning, Katherine May 910-798-7443 Compliance with local UDO requirements 1. General Comments a. Zoning district is CZD B-2 b. This project is associated with rezoning case Z25-12 and was approved with the following conditions. Please add these conditions to the site plan. i. The setbacks as shown on the concept plan must remain. ii. A 6-foot-high screening fence shall be required along the northern boundary of the gravel service yard as shown on the concept plan. iii. No development or outdoor storage shall occur within the existing utility easement as shown on the concept plan. The easement shall constitute an additional spatial buffer and the required transitional buffer shall be installed along the northern portion of the easement if the easement-holder does not permit landscaping inside the easement. iv. The permitted uses are limited to Contactor Office for the main building and Warehousing for the two accessory buildings. c. As stated in the application the intended use is Contractor Office and Warehousing. The Unified Development Ordinance (UDO) defines the uses as i. Contractor Office: An establishment primarily engaged in the day-to-day administrative and clerical services for businesses providing contracted services, such as building contractors, heating and air conditioning (HVAC) repair, landscaping and janitorial services, etc., that require outside and/or fleet storage. The use may include some on-site repair and material preparation work. ii. Warehousing: The storing of goods, wares, and merchandise within an enclosed building, whether for the owners or others. There is little on-site sales activity with the customer present. Uses include: cold storage facilities (including frozen food lockers); distribution warehouses (used primarily for temporary storage pending distribution in response to customer orders); storage warehouses (used for storage by retail stores such as furniture and appliance stores); warehouse storerooms; or similar uses. Insea Marine – 3419 Castle Hayne Road – TRC Review Page | 3 d. The Planning and Land Use Department’s review of the site is for compliance with the UDO and use specific requirements of the specified land use. Any other activity that might occur on the property beyond the definition above should be noted on the application and site plan for additional review and comment. e. Plans note a Duke easement on this property. Please confirm with Duke Energy to get Duke Energy approval for this site plan before proceeding with any other permits. 2. UDO Section 5.1, Parking and Loading a. The calculation for parking is provided on the site plan. However, since the main building will be split between contractor office and workshop space, please show the square footage for each use and show which areas will be used for each use. 3. UDO Section 5.2, Traffic, Access and Connectivity a. Please note that no building permit for any structure shall be issued which requires NCDOT approval for a Driveway Permit until NCDOT has issued the permit approval. Evidence of approval shall accompany the application for building permit. b. The WMPO’s estimated AM and PM traffic generation is provided on the site plan. Thank you. 4. UDO Section 5.3, Tree Retention a. Tree retention standards are included on the plan. A tree removal permit has been submitted, thank you. I will be in touch with next steps. b. For the required mitigation of the removed significant trees, are you planning to replace the lost inches, pay the fee, or a combination of both? c. Note: Land disturbance permits can be issued by county Engineering before a Tree Removal Permit is approved by Planning. However, any trees removed before the Tree Removal Permit is issued may result in enforcement action under Section 5.3.2 of the Unified Development Ordinance to include prohibiting any development of the site for 3 to 5 years. 5. UDO Section 5.4, Landscaping and Buffering a. Just a reminder that replacement inches for removed significant trees cannot be used in required landscaping. b. Per the conditions of this rezoning, a 6-foot-high screening fence shall be required along the northern boundary of the gravel service yard as shown on the concept plan approved by the Board of Commissioners – This is reflected on the plan. Insea Marine – 3419 Castle Hayne Road – TRC Review Page | 4 c. While the grass maintenance was included on C-2, please submit the full landscaping plan as soon as possible which includes the following information: Street yard, parking lot landscaping, foundation plantings, buffer plantings, replacement trees, etc. 6. UDO Section 5.5, Lighting a. Please note that a lighting plan is not required for TRC approval but will be required prior to issuance of construction plan approvals. b. Is any lighting proposed for the site? 7. UDO Section 5.6, Signs a. The plan states no signs are proposed at this time. b. If a future sign is proposed for the site, a separate sign permit must be submitted and reviewed by the county for compliance with Section 5.6 of the UDO for standards at or after the submittal of the separate zoning compliance and construction permits for the primary building or use. Any approvals granted by the TRC for the site design is not an approval for the ultimate size or placement of the sign. 8. UDO Section 5.7, Conservation Resources a. The conservation resources map does not indicate any conservation resources impacting the property, this section does not apply. 9. UDO Article 9, Flood Damage Prevention a. No areas of the property are in a floodplain. NHC Fire Services, Ray Griswold 910-798-7448 Compliance with NC Fire Code 1. Fire extinguishers per NFPA 2. Fire finals required NHC Engineering, Galen Jamison 910-798-7072 Stormwater management and land disturbance 1. Please submit for permit revisions to County stormwater permit STMW-20-0043 and land disturbance permit LNDP-20-00133. Please digitally submit the permit applications documentation with requisite review fees to the COAST online permit portal (https://newhanovercountync-energovpub.tylerhost.net/apps/selfservice#/home) using the referenced permit numbers Insea Marine – 3419 Castle Hayne Road – TRC Review Page | 5 2. All conveyance calculations will need to be updated per the latest NHC stormwater design manual. 3. Please contact the State for their stormwater permit requirements. NHC Environmental Health, Dustin Fenske 910-798-6732 Septic tanks and wells 1. Site plan reflects connection to public water and sewer. Records reflect the site is surrounded by parcels that are connected to public water and sewer. No septic or well issues are apparent for this site design. NHC Addressing, McCabe Watson 910-798-7068 Street naming and property address 1. Each proposed building will need its own individual address. 2. Please contact me for address assignment following TRC approval. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 Public water and sewer 1. CFPUA TRC Comments provided are preliminary comments only. 2. CFPUA is moving toward becoming paperless. When ready to submit plan review package, upload all documents to https://www.cfpua.org/FormCenter/Engineering-3/Engineering- Plan-Review-103. 3. CFPUA water and sewer available. •Capacity is dependent on the analysis of the pipe collection system (gravity and force mains) 4. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE Application Form and a Preliminary Plan, this determination does not guarantee capacity. 5. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the Authority. Insea Marine – 3419 Castle Hayne Road – TRC Review Page | 6 NCDOT, Nick Drees 910-343-3915 Driveway access and state road improvements 1. Please see attachment. WMPO, Caitlin Cerza 910-473-5130 New Hanover County contracted traffic engineering services comments: 1. Please see attachment. Army Corps of Engineers, Brad Shaver 910-251-4611 Information or Requirements if wetlands are impacted 1. No comments. Project information also provided to the following state agencies and non-regulatory local agencies for their awareness: New Hanover County Emergency Management New Hanover County Schools NC Department of Environmental Quality (DEQ) NC DEQ Division of Coastal Management NC DEQ Division of Energy, Mineral, and Land Resources New Hanover County Sustainability Manager NHC Soil & Water Conservation MEMORANDUM To: New Hanover County Technical Review Committee Date: October 9, 2025 Subject: InSea Marine NCDOT Projects: • I-6037: I-140 – US 421 to I-40 Rehabilitate Bridge and pavement. Is in close proximity to this site. WMPO 2045 MTP Projects: • I-6037 – Is also in the 2045 MTP. New Hanover County Projects: • N/A TIA: Based on the 11th edition ITE Trip Generation Manual, a TIA is not required Land Use (ITE Code) Intensity Unit 24 Hour Volumes AM Peak Hour Trips PM Peak Hour Trips Warehouse (150) 23,925 SF 76 27 29 General Office (710) 1,500 SF 30 5 5 STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION JOSH STEIN DANIEL H. JOHNSON GOVERNOR SECRETARY Mailing Address: NC DEPARTMENT OF TRANSPORTATION DIVISION OF HIGHWAYS 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUIT 101 WILMINGTON, NC 28403 Memorandum DATE: October 13, 2025 TO: New Hanover County Technical Review Committee SUBJECT: InSea Marine – 3419 Castle Hayne Road ________________________________________________________________________ These are preliminary comments and are based on the plans as submitted for the proposed site. They are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. General Comments: NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT Online Portal.https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx You can coordinate with the District Office with any questions 910-398-9100. NCDOT Driveway Permit: An NCDOT Driveway permit has been submitted to NCDOT for review (on 10/10/25). •Permit Number D033-065-25-00158. NCDOT Encroachment Agreement: An NCDOT Encroachment Agreement is required for any utility connections or installations within the NCDOT right-of-way (form 16.6). •Refer to the NCDOT UAM Manual and the NCDOT encroachment checklist for required documents and site plan information. An NCDOT Encroachment Agreement is required for any sidewalk or multi-use paths installed within the NCDOT right-of-way (form 16.6). Mailing Address: NC DEPARTMENT OF TRANSPORTATION DISTRICT 3 ENGINEER’S OFFICE 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Roadway Improvements: The plan submitted to New Hanover County shows a right turn lane (extension) into the site while the plans submitted to NCDOT show a standard driveway connection within the merge taper. • One of the plans sets should be revised/removed. Site Plan Comments: Drainage/Stormwater Conveyance: • If the drainage does not naturally flow to the NCDOT right of way the historic drainage pattern should be maintained. NCDOT Standard Drawings: • Include/update the NCDOT Standard Drawings (2024) that are applicable to the development. Sight Triangles and Sight Distance: • Show and label the 10’ X 70’ NCDOT sight triangles. o No obstructions shall be placed within the NCDOT sight triangles. • Show and label the stopping sight distance. o No obstructions shall be placed within the stopping sight distance. Identification Signing and Landscaping: • Identification signing or landscape vegetation within the median and the sight distance triangle must not obstruct the driver’s line of sight. No landscaping or signing will be allowed to exceed 42 inches in height, measured from the Edge of Pavement (EOP) within the median or sight triangle. • All pylon signs in the median or sight distance triangle must provide a vertical clear sight zone between 3 feet-6 inches and 10 feet-0 inches measured from the EOP. Signing located within a clear recovery area shall be of a “breakaway design.” • Only low growing shrubbery, consistent with the NCDOT’s landscaping policies, as contained in the publication “Guidelines for Planting Within Highway Right of Way,” will be allowed within a landscaped median and the sight distance triangle at the entranceway to a development, whether the street or driveway connection to the State Highway System is designated as a public facility or not. Landscaping within the right-of-way and sight distance triangles may require additional approval by the District Engineer. Mailing Address: NC DEPARTMENT OF TRANSPORTATION DISTRICT 3 ENGINEER’S OFFICE 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Gated Entrances: • Show and label any proposed gates with distances to the right of way line. Driveway Radius: • Make sure to accommodate the largest proposed vehicle. Internal Stem Protection: • Label the internal protection stem length for the proposed driveway connection. o Measured from the right-of-way line. Future NCDOT STIP: This development is located within a future STIP. With that in mind, any access that conflicts with the planned transportation infrastructure may be modified and/or removed and there shall not be any compensation made by NCDOT. The current STIP is proposed as a divided facility. Therefore, the permitted access point/point will be restricted as right-in/right-out only in the future. (Pu b l i c R / W ) Ch a i r R o a d Gla d i o l u s R d (6 0 ' P u b l i c R / W ) 35 36 33 34 35 32 31 Inv=32.3 EX.DITop=34.4Inv=32.2 33 31 32 32 33 32 32 32 32 32 32 31 33 34 3333 32 3332 32 33 31 3232 32 33 3231 31 15" RCP 2X8"MAP 8"GUM10"GUM 12"GUM 10"GUM 14"PINE 2X8"GUM 8"MAP 8"GUM2X10"GUM 20"OAK 8"OAK 2X8"OAK 10"OAK 12"OAK10"CHY 10"OAK 14"PINE 12"PINE 10"GUM 12"PINE 8"GUM 8"OAK12"OAK 10"OAK 8"GUM 10"GUM12"OAK 8"GUM 8"GUM 14"PINE 14"PINE 14"PINE 14"PINE 8"GUM 8"MAP 16"GUM 12"MAP 8"MAP 12"MAP 3X4"MAG 10"MAP 10"MAP 8"MAP 2X4"CHY 14"PINE 16"PINE 8"MAP 8"MAP 12"PINE 10"GUM 12"PINE 8"GUM 14"GUM 16"PINE 12"PINE 8"MAP 10"GUM14"GUM 12"PINE 8"MAP 3X8"GUM 10"GUM 12"OAK 8"MAP 8"GUM 12"PINE 14"PINE 12"PINE 12"PINE12"PINE 12"PINE 12"PINE 12"PINE 12"PINE 12"PINE 8"GUM 12"PINE 8"GUM 8"OAK 2X8"MAP 12"GUM 2X8"GUM 3X12"GUM 2X10"OAK 2X8"MAP 10"MAP 10"MAP12"MAP 2X16 " L O A K 14"PINE 8"OAK 12"PINE 18"PINE 8"GUM8"GUM 8"GUM 8"MAP 8"GUM 8"MAP 8"GUM 10"GUM 14"PINE 12"PINE 12"PINE 10"GUM8"MAP8"+10"MAP 10"CHY 10"MAP 24"OAK 18"PINE 12"PINE 18"PINE 12"PINE 2X10"GUM 8"MAP8"MAP 22"PINE12"GUM 18"PINE 18"PINE 20"PINE 8"MAP 12"PINE 8"MAP 8"MAP 18"PINE 16"PINE 16"PINE 10"GUM 18"PINE 8"MAP 8"MAP 8"GUM 8"GUM 8"MAP8"MAP 10"GUM 10"GUM12"GUM 8"MAP 8"MAP8"MAP 8"OAK 8"MAP8"MAP10"MAP 10"GUM 2X8"GUM 16"PINE 22"OAK 10"OAK 10"OAK 10"MAP 12"PINE 16"PINE 8"GUM10"OAK 14"PINE 18"PINE 28"LOAK 2X8"OAK8"OAK 10"OAK 8"GUM 10"OAK36"OAK_CLSTR 16"PINE 8"GUM 14"PINE 14"PINE 14"PINE 12"PINE 8"OAK 12"PINE 10"GUM 8"GUM 8"OAK 8"+10"OAK 8"GUM 8"OAK 12"PINE 8"OAK 8"OAK 20"PINE 14"PINE PROPOSED POND PROPOSED GRAVELPARKING SEP T I C A R E A 12"PINE APPROX. LOCATION EX. 16" WATER MAIN N/FCastle HayneDevelopment Group, LLCDB 6680 Pg 2687ZONING: (CZD) B-2USE: RETAIL EXISTING F.H. EXISTING F.H. EX. ON-SITE DRAINAGESWALES TO BE FILLED 32 C-0 1 EX I S T I N G C O N D I T I O N S , T R E E RE M O V A L / P R O T E C T I O N A N D DE M O L I T I O N P L A N 1" = 30' PROPERTY LINEADJOINERSEASEMENTTREE PROTECTION FENCELIMITS OF DISTURBANCE REGULATED TREES TO BE REMOVED SIGNIFICANT TREES TO BE REMOVED LEGEND REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): 2025-013 CLIENT INFORMATION: InSEA Land Acquisitions, L.L.C.6252 Towles RoadWilmington, NC 28409 OF 4 JAE CDC CDC 24x36 9/26/2025 In S e a M a r i n e O f f i c e PREL I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N I-140 Chair Rd Cas t l e H a y n e R d Rockhill Rd Oakley R d Swartville Rd Gladiolus RdSITE SITE DATA PARCEL ID: R02511-004-017-000 CURRENT ZONING: (CZ)B-2 PROJECT ADDRESS: 3419 CASTLE HAYNE RD.CASTLE HAYNE, NC 28429 CURRENT OWNER: INSEA LAND ACQUISITIONS LLC6252 TOWLES RD. WILMINGTON, NC 28409 TOTAL ACREAGE IN PROJECT BOUNDARY 187,499 S.F. (± 4.3 ac.) EXISTING ONSITE IMPERVIOUS AREAS (SITE IS VACANT): SOILS TYPE: Mu (Murville fine sand - Group A)Pn (Pantego loam - Group A)(Per NHC GIS Soil Map) NOTES:1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY LANDDEVELOPMENT CODE.2. PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTYREGULATIONS.3. EXISTING SURVEYING PERFORMED BY TALBOT LAND SURVEYING, P.C.4. SITE IS LOCATED IN ZONE "X" PER FRIS ON FIRM MAP NUMBER 3720322000, DATED8/28/2018.5. NO WETLANDS, SURFACE WATERS, PROTECTED VEGETATED SETBACKS OR RIPARIANBUFFERS EXIST ON SITE PER DAVEY RESOURCE GROUP, INC.6. PRIOR TO CLEARING, GRADING, OR CONSTRUCTION ACTIVITY, ANY WELLS THAT AREEXISTING MUST BE PROTECTED AROUND EACH WELL HEAD/CASING AND CAPPED.7. ALL PINE TREES ARE ASSUMED TO BE LOBLOLLY PINES. ALL GUM TREES AREASSUMED TO BE SWEET GUMS. OWNER MUST VERIFY SPECIES PRIOR TO CLEARINGAND NOTIFY ENGINEER AND NEW HANOVER COUNTY OF ANY RELEVANT CHANGES. TREE PRESERVATION NOTES:1. PRIOR TO ANY CLEARING, GRADING, OR CONSTRUCTION ACTIVITY, APPROVED TREEPROTECTION FENCING, SUCH AS SAFETY BARRIER FENCING, A WOODEN SLAT SNOWFENCE OR WIRE FENCE, SHALL BE INSTALLED AROUND PROTECTED TREES OR TREESTANDS LOCATED IN CONSTRUCTION AREAS OR OTHER SITE AREAS THAT WILL BEDISTURBED BY CONSTRUCTION ACTIVITIES. THE FENCING SHALL BE A MINIMUM OFFOUR FEET IN HEIGHT AND BE OF DURABLE CONSTRUCTION. TREE PROTECTIVEFENCING SHALL REMAIN IN PLACE THROUGH COMPLETION OF CONSTRUCTIONACTIVITIES.2. NO CONSTRUCTION WORKERS, TOOLS, MATERIALS, OR VEHICLES ARE PERMITTEDWITHIN THE TREE PROTECTION FENCING.3. IF AN EXISTING TREE RETAINED TO COMPLY WITH THE STANDARDS OF THIS SECTIONIS DESTROYED, SUBSTANTIALLY DAMAGED, OR DIES AS A RESULT OF NEGLIGENCE ONTHE PART OF THE PROPERTY OWNER WITHIN THREE YEARS AFTER COMPLETION OFCONSTRUCTION, THEN REPLACEMENT TREES SHALL BE PLANTED ON THE SITE WITHA TOTAL DIAMETER EQUAL TO TWICE THE DIAMETER OF THE RETAINED TREE. AMINIMUM GROWING AREA OF 144 SQUARE FEET SHALL BE PROVIDED FOR EACHREPLACEMENT TREE. IF THE PLANNING DIRECTOR DETERMINES IT IS INFEASIBLE ORFOR REPLACEMENT TREE(S) TO BE ACCOMMODATED ON THE SITE, THEN A PAYMENTMAY BE MADE TO THE COUNTY’S TREE IMPROVEMENT FUND EQUIVALENT TO THEPRICING STANDARDS IN THE COUNTY FEE SCHEDULE. MITIGATION REQUIRED FOR REMOVAL OFSIGNIFICANT TREES QTY SIZE TYPE REPLACEMENTINCHES136"OAK CLUSTER 72.00 1 24"OAK 48.00 122" OAK44.00 TOTAL REPLACEMENT INCHES 164 60'30'15'30'0' Scale: 1"=30' (Pu b l i c R / W ) Ch a i r R o a d PROP. CONTRACTOROFFICE/WORKSHOPBUILDING14,625 SFFFE: 34.5 GRAVEL 18 ' 9' 5' SIDEWALK APP R O X . L O C A T I O N P R O P O S E D SEP T I C A R E A (DE S I G N / P E R M I T T I N G B Y O T H E R S ) Gl a d i o l u s R d (6 0 ' P u b l i c R / W ) 20' Rear Setback & Bufferyard 20' S e t b a c k & B u f f e r y a r d 6' Hi g h S c r e e n i n g F e n c e 25' Front Setback & Streetyard PR O P . W A R E H O U S E BU I L D I N G 3,6 0 0 S F FF E : 3 4 . 5 ASPHALT 36' R35'R3 5 ' 90 ' 20' 62' 26' 30' 35 36 33 34 35 32 31 Inv=32.3 EX.DITop=34.4Inv=32.2 33 31 32 32 33 32 32 32 32 32 32 31 33 34 3333 32 3332 32 33 31 3232 32 33 3231 31 15" RCP 20"OAK 8"OAK10"OAK 12"OAK10"CHY 10"OAK10"GUM 8"GUM 8"OAK12"OAK 10"OAK 12"OAK 2X10"OAK 8"GUM8"GUM 8"GUM 8"MAP 18"PINE 28"LOAK 12"PINE 8"OAK 8"+10"OAK 8"GUM 12"PINE 8"OAK 8"OAK 20"PINE 14"PINE APPROX. LOCATION EX. 16" WATER MAIN 24" FESINV: 30.510'X15'X18" ED SDMH#3RIM: 33.5INV: 30.9 DI#3RIM: 33.5INV: 29.5 DI#4RIM: 33.4INV: 30.5 MATCH EX. ASPHALT±34.9 34.55 15 " R C P 33.9 34.0 34.0 34.0 34.4 34.034.4 34.4 34.4 34.4 34.434.4 34.25 30' 34.0 34.4 34.0 34.4 34.034.4 18" PPES #2INV: 31.255'X10'X12" ED 18" PPES #1INV: 31.4 3' CURB OPENING 3' CURBOPENING DI#5RIM: 33.4INV: 30.8 PROPOSED WETDETENTION BASINTOB: 33.5FP: 32.3NP: 31.0BTM: 24.0 26 . 5 34.0 33.9 N/FCastle HayneDevelopment Group, LLCDB 6680 Pg 2687ZONING: (CZD) B-2USE: RETAIL EXISTING F.H. EXISTING F.H. 33 32 33 33 33 32 33 32 34.0 34.4 8'8' 34.25 TAPER CURB TO FLAT 32 34.7 34.55 32 SDMH#1RIM: 34.0INV: 30.45 1,285 sf 855 sf DI#2RIM: 33.5INV: 30.1 90' C-1 1 SI T E , G R A D I N G , D R A I N A G E , ST O R M W A T E R , & U T I L I T I E S P L A N 1" = 30' SITE DATA PARCEL ID: R02511-004-017-000 CURRENT ZONING: (CZ)B-2 PROJECT ADDRESS: 3419 CASTLE HAYNE RDCASTLE HAYNE NC 28429 CURRENT OWNER: INSEA LAND ACQUISITIONS LLC6252 TOWLES RD. WILMINGTON, NC 28409 TOTAL ACREAGE IN PROJECT BOUNDARY 187,499 S.F. (± 4.3 ac.) PROPOSED USE: CONTRACTORS OFFICE AND STORAGE BUILDING SIZE: 25,425 S.F. TOTAL (3 BUILDINGS) BUILDING HEIGHT: 1-STORY/±25' CALCULATION FOR BUILDING COVERAGE:PROPOSED COVERAGE 25,425 S.F. ÷ 187,499 S.F. = 13.56% BUILDING SETBACKS: FRONT: REQUIRED= 25' PROPOSED= 88'SIDE: REQUIRED= 20' PROPOSED= 131'L/65'RREAR: REQUIRED= 20' PROPOSED= 21' PROPOSED IMPERVIOUS AREAS:BUILDINGS 25,425 S.F.ASPHALT PARKING AREA 7,090 S.F.GRAVEL AREA 44,945 S.F.CONCRETE SIDEWALK 650 S.F.TOTAL 78,110 S.F (41.66%) PARKING REQUIRED:CONTRACTOR OFFICE USE: (3/1,000 sf)1,500 SF/1,000*3 = 5 SPACES WAREHOUSE USE *over 20,000 sf: (1/1,000 sf)23,925 SF/1,000*1 = 24 SPACES PARKING PROVIDED: *6 SPACES (1 ADA)*Warehouse parking provided in the gravel service yards* PARKING LOT INTERIOR LANDSCAPINGREQUIRED 7,090 S.F. * 8% 567 S.F.PROVIDED 2,140 S.F. FOUNDATION PLANTINGS: CONTRACTOR OFFICE BLDG: 65 LF X 15' FACADE X 12%REQUIRED:117 S.F.PROVIDED:135 S.F. WAREHOUSE BUILDINGS:REQUIRED: N/A (BUILDINGS BEHIND GATED FENCE AND NOT VISIBLE FROM R/W) STREETYARD: (25 S.F./LF FRONTAGE. 12.5' MIN./37.5' MAX. WIDTHS)207 LF FRONTAGE 243- 36 LF DRIVEWAYS =207 LF FRONTAGEREQUIRED: 25' X 207 LF 5,175 S.F.PROVIDED:5,175 S.F. EXISTING SEWER AND WATER DEMAND: 0 GPD PROPOSED SEWER AND WATER DEMAND: 250 GPD ESTIMATED TRIP GENERATION (Per Trip Generation Manual 11th Edition):23,925 SF WAREHOUSE (ITE CODE 150)AM PEAK: 4 PM PEAK: 4 DAILY: 41 1,500 SF OFFICE (ITE CODE 710)AM PEAK: 2 PM PEAK: 2 DAILY: 16 PROJECT TOTAL: AM PEAK: 6 PM PEAK: 6 DAILY: 57 REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): 2025-013 CLIENT INFORMATION: InSEA Land Acquisitions, L.L.C.6252 Towles RoadWilmington, NC 28409 OF 4 JAE CDC CDC 24x36 9/26/2025 In S e a M a r i n e O f f i c e PREL I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N I-140 Chair Rd Cas t l e H a y n e R d Rockhill Rd Oakley R d Swartville Rd Gladiolus RdSITE PROPERTY LINERIGHT OF WAYADJOINERSEXISTING EDGE OF PAVEMENTEASEMENT EXISTING FIRE HYDRANT RUNOFF DIRECTION PROPOSED SPOT ELEVATION PARKING LOT INT. LANDSCAPING FOUNDATION PLANTINGS LEGEND DEVELOPMENT NOTES:1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY LAND DEVELOPMENT CODE.2. PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS.3. NO SIGNS ARE PROPOSED AT THIS TIME. ANY FUTURE PROPOSED SIGN IS SUBJECT TO SECTION 5.6. OF THE UDO.3. RUNOFF FROM ALL IMPERVIOUS SURFACES, INCLUDING ROOF DRAINS, TO BE DIRECTED TO WET DETENTION BASIN. 60'30'15'30'0' Scale: 1"=30' UTILITY NOTES:1. WATER SERVICE TO BE PROVIDED BY PROPOSED ON-SITE WELL. DESIGN, LOCATION AND PERMITTING BY OTHERS.2. SANITARY SEWER SERVICE TO BE PROVIDED VIA ONSITE PRIVATE SEPTIC SYSTEM.3. ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS & TELEPHONE SHALL BE INSTALLED UNDERGROUND.4. THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIES DURING CONSTRUCTION.CALL NC811 AT 811 OR 1-800-632-4949. CONTRACTOR IS RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ANY UTILITIES,CURB & GUTTER, PAVEMENT, ETC. THAT MAY BE BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIREDTO AT LEAST THE QUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM.5. SOLID WASTE DISPOSAL IS BY PRIVATE DUMPSTER SERVICE. FIRE & SAFETY NOTES:1. CONSTRUCTION TYPE: II-B (COMMERCIAL)2. BUILDINGS WILL NOT BE SPRINKLED.3. CONTRACTOR SHALL MAINTAIN AN ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES DURING CONSTRUCTION.4. BUILDING INFORMATION SIGNS MUST BE PROVIDED IN ACCORDANCE WITH THE "2018 NC FIRE CODE APPENDIX J"REQUIREMENTS.5. CONTRACTOR SHALL SUBMIT A RADIO SIGNAL STRENGTH STUDY FOR ALL COMMERCIAL BUILDINGS THAT DEMONSTRATES THATEXISTING EMERGENCY RESPONDER RADIO SIGNAL LEVELS MEET THE REQUIREMENTS OF SECTION 510 OF THE 2018 NC FIRECODE.6. ANY DRIVEWAY GATE TO BE SIREN ACTIVATED AND HAVE KNOX KEY OVERRIDE.7. ALL FIRE HYDRANTS MUST BE INSTALLED WITH 5 INCH STORZ QUICK CONNECTS ON A 4.5 INCH STEAMER IN COMPLIANCE WITHNHC FIRE SERVICE REQUIREMENTS.8. NO OBSTRUCTIONS WITHIN 36" AROUND A FIRE HYDRANT, INCLUDING BUT NOT LIMITED TO, STREET SIGNS, LANDSCAPING ANDUTILITY POLES AND BOXES.9. NEW HYDRANTS MUST BE BROUGHT INTO SERVICE PRIOR TO COMBUSTIBLE MATERIALS DELIVERED TO THE JOB SITE.10. ANY GATES WILL REQUIRE PROPER PERMITTING THROUGH A KNOX ENTRY SYSTEM FOR EMERGENCY ACCESS. 34.55 NCDOT | Division 3 | District 3 Project Name:_____________________________ Date:_______________ Applicant Checklist NCDOT Checklist Driveway Application Process and Site Plan Requirements ALL APPLICATIONS SHALL BE ACCOMPANIED BY COMPLETE AND DETAILED SITE PLANS THAT ADHERE TO THE POLICIES LISTED IN THE POLICY ON STREET AND DRIVEWAY ACCESS TO NORTH CAROLINA HIGHWAYS AND THIS DOCUMENT. FAILURE TO ADHERE TO THESE POLICIES WILL RESULT IN THE RETURN OF THE APPLICATION TO THE APPLICANT FOR REVISION. ***THE NCDOT WILL NOT BEGIN THE REVIEW PROCESS ON INCOMPLETE APPLICATIONS*** Electronic Pre-Submittals In an effort to save time and resources, we are happy to provide an initial assessment of a driveway permit submittal’s plans via email to identify any major issues up front. This initial assessment can be followed up with a submittal of one digital copy of the plans along with all other required documents. All Permit applications shall be submitted through the online portal https://connect.ncdot.gov/site/Permits/Pages/default.aspx In the notify email section of the portal application please include the District Office email (Div3Dist3@ncdot.gov). See the last pages for further instruction. Online resources: •NCDOT Policy on Street and Driveway Access to North Carolina Highways: https://connect.ncdot.gov/projects/Roadway/RoadwayDesignAdministrativeDocuments/Policy%20on%20Street%20an d%20Driveway%20Access.pdf •NCDOT Policies and Procedures for Accommodating Utilities on Highway Rights of Way: https://connect.ncdot.gov/municipalities/Utilities/Pages/UtilitiesManuals.aspx •Electronic Forms Database: https://connect.ncdot.gov/Pages/default.aspx 1) a.Cover Letter Include contact information for applicant and engineer, including email address, mailing address, and phone number. Include the parcel number(s), description of all phases of the development and future land uses to be served by the permit, and a description of the adjoining land owned or controlled by the applicant. b.NCDOT Street and Driveway Access Permit Application (form downloadable via link below) https://connect.ncdot.gov/resources/BusinessForms/TEB-65-04.doc c.$50.00 Inspection Fee Per Access Point Attach to Permit Application form (not applicable for municipalities, churches, and schools) d.NPDES Stormwater Permit Compliance Certification (form downloadable via link below) https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/NPDESstatement.doc e.Verification of Compliance with Environmental Regulations (form downloadable via link below) https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/VCER-1.pdf f.Site Plans (to include the “Master Plan” of a tract even if only a small portion is being developed first) Additional site plan requirement details can be found in section 2 of this document. g.Design Plan Requirements for projects involving roadway improvements If roadway improvements are required as part of the permit, then roadway plans, pavement marking plans,signing plans, and traffic control plans will be required - See Section 6 for more information Y N n/a Engineering Studies The applicant may be required by the District Engineer to submit studies based on, but not limited to, the parameters outlined herein. If study requirements of the local government agency are more restrictive than the NCDOT requirements, then local government requirements will govern. However, this does not imply that the NCDOT is obligated to approve entrance designs that are too constrictive to allow smooth and safe traffic flow. All studies including, but not limited to, Traffic Impact Analyses (TIA), traffic signal studies, and drainage studies, must be prepared under the direct charge of and sealed by a North Carolina licensed Professional Engineer. Section 1: Requi red Documents |Required documents to accompany all Initial Driveway Application Submittals Please note that these are the minimum requirements of all driveway permit applications. All required documentation shall be submitted through the online portal as PDF files, with the exception of the Performance and Indemnity Bond and the $50 Inspection Fee(s), these should be mailed or delivered to 5501 Barbados Blvd, Castle Hayne, NC 28429. If a Traffic Impact Analysis and/or roadway improvements are deemed necessary as a condition of the permit, there may be additional submittal materials required. State of North Carolina | Department of Transportation | Division 3 | District 3 5501 Barbados Blvd, Castle Hayne, NC 28429 Form Updated 10/15/2021 (910) 398-9100 T NCDOT Permit #___________________ Y N n/a Section 1: Required Documents (continued) 2)Required documents to accompany all Driveway Applications PRIOR TO FINAL APPROVAL a.Site Plans One (1) digital copy (PDF) unless otherwise requested by the District Office. Additional site plan requirement details can be found in section 2 of this document. b.Performance and Indemnity Bond Information/Forms See last page of document for bond information and forms c.Performance and Indemnity Bond Amount 100% of the cost of the work within NCDOT Right-of-Way (R/W) based on the attached estimate determined by the applicant's engineer and approved by the District Engineer. Bond hold letter required for for municipalities, churches, and schools. See pages 101-105 in the Policies and Procedures for Accommodating Utilities on Highway Rights of Way for acceptable bond types d.Radius Encroachment Letter (if applicable) If driveway radius encroaches on the frontage of an adjacent property, a Radius Encroachment will be required e.Hold Harmless Letter (if applicable) If the Permit is within the limits of an active NCDOT project, a Hold Harmless letter from the NCDOT contractor will be required. If the project is in preconstruction, coordinate with the Department's Project Development Unit Section 2: General Site Plan Requirements | All site plans shall include and show, at a minimum, the items listed below Page numbers reference the NCDOT Policy on Street and Driveway Access to North Carolina Highways 1)Drawn to a scale of 20, 30, 40, or 50 feet per inch and the scale shall be shown 2)North arrow, vicinity map, date of plan, and date of most-recent revision if applicable 3)Contact information of applicant and engineer, including mailing address, phone number, and email address 4)Show R/W lines, highway control of access, and property lines 5)All existing utilities (including handholes) and easements 6)R/W width 7)Existing posted speed limit(s) and design speed limit(s) 8)Show all property lines, intersections, signals, signal loops, railroads, or crossovers within 500’ in all directions of the property lines of the proposed development 9)Show location of sidewalks, crosswalks, greenways, multi-use paths, curb ramps, railroads, bus stops, and any other relevant transportation facilities in the development area 10)Include a plan sheet showing full site build-out and land use 11)Buildings shown with “gross leasable area” 12)Width of property frontage 13)Distance from R/W to buildings and gasoline service islands 14)Distance from R/W to existing/proposed Edge of Pavement (EOP) (pages 32 & 34) 15)All streams, bridges, retaining walls, signs, or other fixed objects such as trees, utility poles, traffic signals, etc. Section 3: Driveway Plan Requirements | All driveway plans shall include and show, at a minimum, the items listed below 1)Provide comprehensive survey within the existing R/W on both sides of the road for a distance of 500’ in all directions from the development’s property lines. Provide additional hydraulic survey data to the nearest storm water inlet/outlet including ditch lines and storm water pipes, if located outside of the 500' distance. 2)Lane configurations and widths of all existing and proposed driveways, roadways, and adjacent roadways 3)All driveway widths (2-way: 20’ minimum, 36’ maximum | 1-way: 12’ minimum, 24’ maximum | with island: 14'ingress, 18' egress) (pages 50 & 77) 4)Driveway Profile - In shoulder sections, maintain minimum 2% fall from edge of travel way for required shoulder width distance Primary: 8’ minimum | Secondary: 6’ minimum 5)All existing and/or proposed driveway radii (20’ minimum, 50’ maximum, 30’ typical) (pages 34 & 51) In curb and gutter sections, use City of Wilmington flare (SD 3-03.3) - (see attached) In shoulder sections, show grades at the EOP and centerline 6)No curbing is allowed within NCDOT R/W along shoulder sections except as part of a driveway island (page 31) 7)Driveway angles of approach to existing roadway (90° preferred, 75°-90° required for 2-way driveways, 45°-90° allowed for right-in/right-out on a case-by-case basis) (page 51) 8)Driveway Profile (pages 42- 43) Y N n/a Y N n/a □□ □□ □ □ Y N n/a Y N n/a Y N n/a Y N n/a Section 3: Driveway Plan Requirements (continued) 9)Driveway Pavement Cross Section (to be in place from EOP to edge of R/W) Asphalt: 8” ABC stone and 1.5” S9.5B Concrete: 6” of concrete 10)Driveway Offset (driveway EOP to property line; page 75): Minimum: 20’ 11)Corner Clearance (radius point to radius point; page 52)Minimum: 50’ Desirable: 100’ or Municipal std. 12)Minimum 10’x70’ sight triangles at driveways (measured from and along the R/W line) (page 31) 13)Sight Distance (length of sight-distance in both directions shown for each driveway; pages 27-29) 14)Driveways should be aligned with existing opposing driveways or correct offset should be provided (pages 40-41) 15)Distance between driveways being requested (if applicable; page 51) 16)Minimum internal storage areas with specified queues (pages 31-33) 17)Minimum protected driveway stem(s) provided and indicated (pages 33-34) 18)Indicate any gated entrances (100’ minimum setback from R/W required) - traffic queuing study may be required | Section 6: Roadway Plan Requirements If off-site improvements are required, roadway plans shall show, at a minimum, the items below 1)Full width typical sections must be shown (paved shoulders to match the typical section of the adjacent roadway) 2)Minimum Asphalt Typical Section (for turn lanes and/or paved shoulders) Adjacent recently-completed or upcoming TIP projects w/ different typical sections may supersede those below •Primary Routes (US & NC) and Secondary Routes with Annual Average Daily Traffic (AADT) ≥10,000 5.5” B25.0C, 3” I19.0C, 1.5” S9.5C; any overlay of existing pavement is to be a minimum of 1.5” S9.5C •Secondary Routes with AADT<10,000 5.5” B25.0C, 1.5” S9.5B; any overlay of existing pavement is to be a minimum of 1.5” S9.5B 3)Pavement overlay is required if modification of existing pavement markings and/or lanes is necessary The grinding of pavement markings will not be allowed 4)Shoulder Widths (Paved + Unpaved) Primary: 8’ minimum | Secondary: 6’ minimum 5)Ditch Slopes - front and back slopes - minimum 3:1 or flatter 6)Indicate existing roadway grade 7)All taper lengths and deceleration lengths should be appropriately designed for the given design speed (page 78) 8)All turn lanes should be designed according to the Driveway Manual and Roadway Standard Drawings (page 79) See 1205.04 Sheets 1 & 2 and 1205.05 Sheet 1 of the Roadway Standard Drawings for details 9)Pavement marking and signing plans are required - plans must be approved by Division Traffic Services 10)Traffic control plans are required - Detailed phasing plans may be required based on project type and location 11)New and/or revised signal plans must be included for new installations and if signal modifications are required All signal plans must be reviewed and approved by Division Traffic Services and the Signal Design Unit. A Traffic Agreement must be completed to facilitate the review. Contact Division Traffic Services at (910) 341-2200. | Section 4: Drainag e Requirements All drainage features on NCDOT Right-of-Way shall adhere to, at a minimum, the items listed below Section 5: Internal Circ ulation Requirements |All internal circulation details shall adhere to, at a minimum, the items listed below 1)Interior driveway channelization stems Minimum 100’ from the ROW or at the discretion of the District Engineer 2)Traffic flow pattern 3)Traffic control devices 4)Pavement Markings Y N n/a Y N n /a Y N n/a Y N n/a Y N n/a Y N n/a Y N n/a Y N n/a 1)Pipe Cover Minimums (measured from top of pipe to subgrade) High Density Polyethylene (HDPE): 24” | Corrugated Aluminum (CAP): 12” | Reinforced Concrete (RCP): 12” 2)Pipe End Treatment (see Roadway Design Manual 5-20, B-2) Pipes ≤24" on multilane highways posted above 45mph require Parallel Pipe End Sections See 310.02 and 310.04 of the Roadway Standard Drawings for details Pipes >30" on multilane highways posted above 45mph require guardrail Pipes ≥36" require an endwall on the inlet end 3)All proposed Drainage is to be provided inside existing R/W. Otherwise, additional R/W or a permanently dedicated drainage easement will be required to accommodate the proposed project drainage 4)All sizes, types, and invert elevations of existing/proposed pipes and drainage structures must be shown(see Sec.3 #1 for survey requirements) 5)Provide spot elevations along frontage of driveway (at EOP and centerline) 6)Provide grades and spot elevations for existing and proposed ditches 7)Show how drainage will be accommodated along property frontage(District Engineer may require applicant to provide drainage calculations when warranted) C/L EOTEOP P/L R/WR/W R/W EOP EOP EOP EOP NTS R/W P/L DRAINAGE FLOW DRAINAGE FLOW DRAINAGE FLOW SHOULDER WIDTH SHOULDER WIDTH SHOULDER WIDTH SHOULDER WIDTH S IGHT T R IANG LE 10 ' BY 70 'S I GHT T R I ANGL E10' B Y 70' DRIVEWAY RR MIN. 30'MIN. 30' NO ROADWAY IMPROVEMENT COMMERCIAL DRIVEWAY WITH NORMAL CROWN ROADWAY 6" LOWER THAN THE EDGE OF PAVEMENTMIN 2% FALL AWAY or 20' AWAY FROM THE PROPERTY LINEDRIVEWAY SHALL BE LOCATED AT LEAST PIPE/TYPE/SIZE WIDTH CON CR ET E /ASP HA LT LOCAL NAME ROAD POSTED SPEED ( ) MPH WIDTH WIDTHSR NUMBER SITE ADDRESS:TAX PARCEL # 20191115 PARALLEL END S.D. 310.02 INVERT ELEVATION PARALLEL END S.D. 310.02 INVERT ELEVATION 20' AWAY FROM THE PROPERTY LINEDRIVEWAY SHALL BE LOCATED AT LEAST OR 500' OF XYZ SURVEY DATA PAST THE PROPERT LINENEAREST OUTFALL ELEVATION OR 500' OF XYZ SURVEY DATA PAST THE PROPERT LINENEAREST OUTFALL ELEVATION