Loading...
HomeMy WebLinkAbout11-5-2025 TRC Agenda Packet TECHNICAL REVIEW COMMITTEE AGENDA November 5th, 2025 New Hanover County’s Technical Review Committee (TRC) will meet Wednesday, November 5th, 2025 at 2:00 p.m. to discuss the below items. The Technical Review Committee (TRC) is a staff-level group that reviews projects for compliance with the regulations administered by each respective review agency. The TRC meetings are considered staff meetings with applicants and are not public hearings. The TRC meeting is an opportunity for applicants to speak with county staff and any voluntarily participating state agencies about the review comments they have been provided. No voting is involved in the technical review process and no approvals or denials are made at TRC meetings. Following the TRC meeting, applicants are responsible for updating their plans to address review comments. Applicants are also responsible for coordinating with state and federal agencies for compliance with any additional requirements. Information about the projects can be found on online at the county’s Development Activity page. This meeting will be conducted remotely via teleconference. Interested parties can listen to the November 5, 2025 TRC meeting by calling 336-218-2051 and entering conference ID: 884 124 273# 2 Agenda Items Item 1: Heron Cove Major Residential Subdivision – 6425 Gordon Road – SUBPP-25-0028 • Request by Craig Johnson with Heron Cove Development for a 67-lot single- family residential development • The site is 10.87 acres and is located at 6425 Gordon Road, zoned (CZD) R-5, tied to rezoning case Z25-06 • The engineer is Charlie Cazier with Intracoastal Engineering (charlie@intracoastalengineering.com) • The case planner is Zach Dickerson (zdickerson@nhcgov.com) Item 2: Pandion Drive Major Residential Subdivision – Pandion Drive – SUBPP- 25-0029 • Request by Senca Properties for a 52-lot single-family residential development • The site is 20.93 acres and is located on Pandion Drive, currently unaddressed. The zoning is R-15 • The engineer is Jade Kane with Timmons Group (jade.kane@timmons.com) • The case planner is Zach Dickerson (zdickerson@nhcgov.com) Item 3: Seabreeze Cottages Major Residential Subdivision – 7641 Carolina Beach Road – SUBPP-25-0030 • Request by Wes Reynolds with SB Cottages Investment LLC for a 46-unit row- style (townhome) dwelling residential development • The site is 7.65 acres and is located at 7641, 7645 and 7647 Carolina Beach Road, zoned (CZD) R-5, tied to rezoning case Z23-14 • The engineer is Jennifer Williams with Nichols Engineering PLLC (jenn@nicholsengpllc.com) • The case planner is Robert Farrell (rfarrell@nhcgov.com) 3 Item 4: InSea Marine – 3419 Castle Hayne Road – SITECN-25-000101 • Request by Stephen Conway with InSea Land Acquisitions, LLC for a 25,425 sq ft Contractors Office and Warehouse • This site is 3.4 acres and is located at 3419 Castle Hayne Road and is zoned (CZD) B-2, from recent rezoning case Z25-12 • The engineer is Charlie Cazier with Intracoastal Engineer (charlie@intracoastalengineering.com) • The case planner is Katherine May (kmay@nhcgov.com) Item 5: Commercial Flex Space – 3305 Fredrickson Road – SITECN-25-000102 • Request by Natalie Oakes with DAE Building, Inc. for a 9,600 sq ft commercial flex space • The site is 0.8 acres and is located at 3305 Fredrickson Road and is zoned I-2 • The engineer is Nick Lauretta with Riverview Engineering (nlauretta@rivervieweng.com) • The case planner is Katherine May (kmay@nhcgov.com) Item 6: Flex Office Building – 3008 N Kerr Ave – SITECN-25-000103 • Request by Vince Burgess with 3008 N Kerr LLC for a 7,069 sq ft office/warehouse building • The site is 1.24 acres and is located at 3008 N Kerr, zoned I-2 • The engineer is Mark Hargrove with Port City Consulting Engineers, PLLC (mark@portcityeng.com) • The case planner is Katherine May (kmay@nhcgov.com) Heron Cove – Major Subdivision – TRC Review Page | 1 To: Craig Johnson, Heron Cove Development From: Zach Dickerson, Senior Planner Date: November 5, 2025 TRC Review PID#: R04300-003-025-000, R04300-003-057-000, R04300-003-026-010 Egov# SUBPP-25-0028 Subject: Heron Cove- Major - Preliminary Plan TRC Review Technical Review Committee (TRC) General Information The TRC is a staff-level group of local government officials that reviews projects for compliance with the local regulations administered by each respective review agency. Voluntarily participating state agencies may also provide comments. And general information and non-binding recommendations about the site may also be provided by government agencies. The TRC meetings are considered staff meetings and are not public hearings. The TRC meeting is an opportunity for applicants to speak with county staff and any voluntarily participating state or federal agencies about the review comments they have been provided. No voting is involved in the TRC process, and no final approvals or denials are made at the TRC meetings. Following the TRC meeting, applicants are responsible for updating their plans to address review comments. Those revised plans need to be resubmitted to the assigned case planner. The case planner will facilitate additional reviews until all comments have been addressed, and the necessary departments have stated the plans comply with the applicable minimum requirements for development. Following any future TRC approval, the project is required to obtain additional permits to include a zoning compliance permit for the site. Applicants are also responsible for coordinating with state and federal agencies for compliance with any additional requirements. Any activity on the property that is not approved as part of the TRC review and zoning compliance permit will be considered a violation of the UDO and subject to enforcement action under Article 12 Violations and Enforcement. Heron Cove – Major Subdivision – TRC Review Page | 2 The following comments have been received for the November 5, 2025, TRC meeting. Additional comments may be made upon further review of subsequent revisions. Planning, Zach Dickerson 910-798-7450 Compliance with local zoning requirements 1. General Comments a. Zoning is Conditional R-5, tied to rezoning case Z25-06. b. This is a performance residential subdivision. i. Density for Performance Residential: R-5 allows a maximum density of 8 dwelling units per acre. Rezoning case Z25-06 caps the unit count at 67 units, which is 20 less units than a maxed-out R-5 would allow. ii. If the Class IV soils on the site (outlined below) are to be set aside as Conservation Space, they would need to be denoted as such. Because the density cap is set by the Conditional zoning district, they are not required to be set aside. We are still pointing them out in the TRC comments to make the applicant aware. No further action needs to be taken. iii. The site plan notes Johnston Soils on the site which are considered Class IV soils. There are approximately 32,600 square feet/.75 acres of Johnston Soils on the site, noted in the image below. The exact square footage of these can be determined by a soil scientist. These only need to be conserved if they are being counted towards density. Heron Cove – Major Subdivision – TRC Review Page | 3 iv. Per UDO Section 3.1.D.2., Density: 1. “In calculating the density for a proposed Performance Residential Development, the areas in subsections 1 and 2 [below] shall first be subtracted from the gross area of land to be committed to development. In lieu of subtracting Dorovan, Johnston, and Pamlico soils, the developer may choose to preserve 100% of such areas as conservation space in accordance with Section 5.7, Conservation Resources. a. Subsection 1: All natural lakes, ponds, rivers, or marshes; and b. Subsection 2: All areas of Class IV soils as defined in A Classification of Soils in New Hanover County for Septic Tank Suitability. All calculation shall be rounded to the nearest whole unit. v. Density Calculations: 1. Total site acreage = 10.87 acres 2. If the Class IV soil areas are being conserved, please denote this on the concept plan. 3. The R-5 zoning district typically allows for up to 8 dwelling units per acre. 4. The CZD R-5 on this site as part of rezoning Z25-06 has a maximum of 67 dwelling units on the site. 5. The application proposes 67 dwelling units. As mentioned above, this is 20 less than could be proposed under a typical R-5. The soils are not required to be set aside for density purposes. c. As noted above, site was rezoned under case Z25-06. Rezoning conditions are noted below as part of the TRC comments, and are already included on the site plan. Thanks! Notes on the conditions in bold below. 1. The project will include emergency only access to Daniel Boone Trail. Condition met through note of “Siren activated gate at boundary.” 2. The project will include a minimum one-car garage with each home and ability to park two cars in the driveway of each home. This would need to be enforced when each home comes through for building permits. We’ll work with zoning to get a list of addresses so we can double check in the system when permits are filed for. Heron Cove – Major Subdivision – TRC Review Page | 4 3. The project will provide a six-foot fence at the rear of each lot of the development. Please show approximate line of fence location on the preliminary plan. 4. Two trees at least 2 inches in diameter at breast height will be planted on each lot, to be maintained by the HOA through a landscaping easement on each lot. Tree maintenance and preservation will be included in the covenants which are subject to county review before recording of final plat. Please note easement on preliminary plan, to be finalized 5. The 18-inch oak tree in the middle of the internal road, around which the road has been reconfigured, will be preserved on the site. Noted on site plan, will be also noted in the Tree Removal Permit. 6. There will be two 10-foot in width bicycle and pedestrian access easements in this development, connecting to Daniel Boone Trail and Gordon Acres Drive. These don’t need to be finalized until final platting, but would be helpful if shown on preliminary plan. 7. A public utility easement meeting the minimum standards of CFPUA for water and sewer infrastructure shall be dedicated along the bicycle and pedestrian easement connection to Gordon Acres Drive at the time the final plat is recorded with the New Hanover County Register of Deeds. Same as above. 8. Existing trees in the site’s open space that do not impact required land grading or other improvements and future amenities as identified in the required Tree Removal Permit will be preserved. Will be addressed in the Tree Removal Permit. 9. Maintenance of the fence required in condition #3 above will be the responsibility of the property owner and included in the Homeowner’s Association Covenants, to be recorded with the final plat with the Register of Deeds. Will be addressed in the final plat. 10. The 2025 New Hanover County Floodplain Advisory Study shall be shown on the final plat for this development, noting on lots 7 & 59 the flood risk as part of that study, and shall be recorded with the final plat with the New Hanover County Register of Deeds. The plat will note that this study is non-regulatory. Will be addressed in the final plat. Heron Cove – Major Subdivision – TRC Review Page | 5 d. Staff recommend including the location of traffic calming devices on the preliminary plans. Installation of traffic calming devices are not required, but including potential locations on the plan ensures the future HOA / owners will have the opportunity to install them without conducting a traffic study. 2. UDO Section 5.1, Parking and Loading a. Single Family Dwelling Units require a minimum of two parking spaces per unit. Per the conditions in the rezoning, there will be a minimum one car garage with ability to park two vehicles in the driveway on each lot. This requirement will be met by this condition. 3. UDO Section 5.2, Traffic, Access and Connectivity a. Please note that no building permit for any structure shall be issued which requires NCDOT approval for a Driveway Permit until NCDOT has issued the permit approval. Evidence of approval shall accompany the application for building permit. 4. UDO Section 5.3, Tree Retention a. Note: Land disturbance permits can be issued by county Engineering before a Tree Removal Permit is approved by Planning. However, any trees removed before the Tree Removal Permit is issued may result in enforcement action under Section 5.3.2 of the Unified Development Ordinance to include prohibiting any development of the site for 3 to 5 years. b. Tree survey and worksheet received. Tree Removal Permit can be found at this link: https://www.nhcgov.com/DocumentCenter/View/1239/Tree-Removal-Permit-PDF 5. UDO Section 5.4, Landscaping and Buffering a. The landscaping requirement for two trees to be planted on each property and maintained in a landscaping easement by the HOA has been included as a condition on the site plan. b. This maintenance/landscaping easement will be confirmed during the final plat process. 6. UDO Section 5.5, Lighting a. Please note under 5.5.2.A that a lighting plan is not required for single-family residential projects and the county does not require streetlights, however a lighting plan is required for any amenity area. Heron Cove – Major Subdivision – TRC Review Page | 6 7. UDO Section 5.6, Signs a. Please ensure the proposed entrance feature noted on the cover sheet is outside of the 10x70’ sight triangles required by NCDOT. b. For any signs on the site, a separate sign permit must be submitted and reviewed by the county for compliance with Section 5.6 of the UDO for standards at or after the submittal of the separate zoning compliance and construction permits for the primary building or use. 8. UDO Section 5.7, Conservation Resources a. The site plan shows wetlands on the site delineated by Southern Environmental Group, though there are no Conservation Resources noted on the site per the New Hanover County Conservation Resource Maps. 9. UDO Section 5.8, Open Space Requirements a. The amount of open space required for this development is 20% of the total acreage. i. 20% of 10.87 acres = 2.17 acres of open space required ii. Site plan notes 3.25 acres of open space provided. 10. UDO Article 6, Subdivision Design and Improvements. a. The New Hanover County Private Roadway Design Manual requires a 45’ ROW for roads and a minimum 24’ width travelway. i. The road detail shows only a 20’ width travel way. b. Sidewalks provided on both sides of the road- all good. c. Block length is good. d. While the links/nodes ratio does not meet the required minimum connectivity ration of 1.4, the development is surrounded by private roads and does provide an emergency connection to Daniel Boone Trail. 11. UDO Article 9, Flood Damage Prevention a. This property is not located in a regulatory floodplain. Heron Cove – Major Subdivision – TRC Review Page | 7 b. There are parts of this property located in the Northeast Floodplain Study. While this study is not regulatory, there is a condition required to place notice on lots 7 & 59 that they may have flooding impacts as noted in the flood study. NHC Fire Services, David Stone 910-798-7458 Compliance with the NC Fire Code 1. A fire hydrant will need to be located at the entrance to the development and every one thousand feet. 2. If the emergency access is to be gates, the gate plans must be submitted for review. 3. No other traffic calming or gates without TRC approval. NHC Engineering, Galen Jamison 910-798-7072 Stormwater management and land disturbance 1. A request for additional information has been provided to the applicant for County stormwater permit and land disturbing permit. The stormwater and land disturbing review fees must be paid prior to permit issuance. 2. Please contact the State for their stormwater permit requirements. NHC Environmental Health, Dustin Fenske 910-798-6732 Septic tanks and wells 1. Plans reflect connection to public water. Drinking water wells will need to be identified and protected for 6437, 6431, 6427, and 6425 Gordon Road during the demolition process. These wells shall be properly abandoned by a Certified Well Driller. 2. Site plan reflects connection to public sewer. Existing septic tanks for 6437, 6431, 6427, and 6425 Gordon Road must be properly abandoned. Abandon by pumping, crushing, and filling. Proposed infrastructure such as stormwater ponds appear to meet setbacks to all surrounding properties’ septic systems. Heron Cove – Major Subdivision – TRC Review Page | 8 NHC Addressing, McCabe Watson 910-798-7068 Street naming and property address 1. Street name “Heron Cove Drive” has been approved for use. 2. Please contact me for address assignment following TRC approval. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 Public water and sewer 1. CFPUA TRC Comments provided are preliminary comments only. 2. CFPUA is moving toward becoming paperless. When ready to submit plan review package, upload all documents to https://www.cfpua.org/FormCenter/Engineering-3/Engineering- Plan-Review-103. 3. CFPUA water and sewer available via mainline extension. 4. Plans have been submitted to CFPUA for review. NCDOT, Nick Drees 910-343-3915 Driveway access and state road improvements 1. Comments attached. WMPO, Luke Hutson 910-473-5130 New Hanover County contracted traffic engineering services comments: 1. Comments attached. Project information also provided to the following state agencies and non-regulatory local agencies for their awareness: Army Corps of Engineers New Hanover County Soil & Water Conservation New Hanover County Emergency Management New Hanover County Schools NC Department of Environmental Quality (DEQ) NC DEQ Division of Coastal Management NC DEQ Division of Energy, Mineral, and Land Resources STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION JOSH STEIN DANIEL H. JOHNSON GOVERNOR SECRETARY Mailing Address: NC DEPARTMENT OF TRANSPORTATION DIVISION OF HIGHWAYS 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUIT 101 WILMINGTON, NC 28403 Memorandum DATE: October 13, 2025 TO: New Hanover County Technical Review Committee SUBJECT: Heron Cove – 6425 & 6437 Gordon Road ________________________________________________________________________ These are preliminary comments and are based on the plans as submitted for the proposed site. They are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. General Comments: NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT Online Portal.https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx You can coordinate with the District Office with any questions 910-398-9100. NCDOT Driveway Permit: An NCDOT Driveway Permit is required. Submit plans in accordance with pages 14 and 15 of the Policy on Street and Driveway Access to North Carolina Highways to include access locations within 500’ of the proposed access on both sides of the State Road. Submit to the local NCDOT District Engineer’s Office. • Refer to the NCDOT checklist (included) for required documents and site plan information. NCDOT Encroachment Agreement: An NCDOT Encroachment Agreement is required for any utility connections or installations within the NCDOT right-of-way (form 16.6). • Refer to the NCDOT UAM Manual and the NCDOT encroachment checklist for required documents and site plan information. An NCDOT Encroachment Agreement is required for any sidewalk or multi-use paths installed within the NCDOT right-of-way (form 16.6). Mailing Address: NC DEPARTMENT OF TRANSPORTATION DISTRICT 3 ENGINEER’S OFFICE 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Required Roadway Improvements: A right turn lane may be needed for the proposed site access. Development Review Coordination (due to STIP U-6206): The proposed development falls within an active NCDOT STIP Project (U-0602). Any development that falls within an active project will require additional review/coordination/approvals/requirements/excreta by NCDOT. A reimbursable agreement may be needed for any work that falls within the project limits. Site Plan Comments: Gordon Road should show the new layout per the U-6206 STIP plans. • Associated U-6202 plan sheets have been included for reference. • Make sure to account for the drainage easement and bank stabilization being built with the U-6202 project. Daniel Boone Trail and Gordon Acres Drive are private roads. NCDOT Standard Drawings: • Include/update the NCDOT Standard Drawings (2024) that are applicable to the development. Sight Triangles and Sight Distance: • Show and label the 10’ X 70’ NCDOT sight triangles. o No obstructions shall be placed within the NCDOT sight triangles. • Show and label the stopping sight distance. o No obstructions shall be placed within the stopping sight distance. Identification Signing and Landscaping: • Identification signing or landscape vegetation within the median and the sight distance triangle must not obstruct the driver’s line of sight. No landscaping or signing will be allowed to exceed 42 inches in height, measured from the Edge of Pavement (EOP) within the median or sight triangle. Mailing Address: NC DEPARTMENT OF TRANSPORTATION DISTRICT 3 ENGINEER’S OFFICE 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 • All pylon signs in the median or sight distance triangle must provide a vertical clear sight zone between 3 feet-6 inches and 10 feet-0 inches measured from the EOP. Signing located within a clear recovery area shall be of a “breakaway design.” • Only low growing shrubbery, consistent with the NCDOT’s landscaping policies, as contained in the publication “Guidelines for Planting Within Highway Right of Way,” will be allowed within a landscaped median and the sight distance triangle at the entranceway to a development, whether the street or driveway connection to the State Highway System is designated as a public facility or not. Landscaping within the right-of-way and sight distance triangles may require additional approval by the District Engineer. Gated Entrances: • Show and label any proposed gates with distances to the right of way line. Internal Stem Protection: • Label the internal protection stem length for the proposed driveway connection. o Measured from the right-of-way line. NCDOT | Division 3 | District 3 Project Name:_____________________________ Date:_______________ Applicant Checklist NCDOT Checklist Driveway Application Process and Site Plan Requirements ALL APPLICATIONS SHALL BE ACCOMPANIED BY COMPLETE AND DETAILED SITE PLANS THAT ADHERE TO THE POLICIES LISTED IN THE POLICY ON STREET AND DRIVEWAY ACCESS TO NORTH CAROLINA HIGHWAYS AND THIS DOCUMENT. FAILURE TO ADHERE TO THESE POLICIES WILL RESULT IN THE RETURN OF THE APPLICATION TO THE APPLICANT FOR REVISION. ***THE NCDOT WILL NOT BEGIN THE REVIEW PROCESS ON INCOMPLETE APPLICATIONS*** Electronic Pre-Submittals In an effort to save time and resources, we are happy to provide an initial assessment of a driveway permit submittal’s plans via email to identify any major issues up front. This initial assessment can be followed up with a submittal of one digital copy of the plans along with all other required documents. All Permit applications shall be submitted through the online portal https://connect.ncdot.gov/site/Permits/Pages/default.aspx In the notify email section of the portal application please include the District Office email (Div3Dist3@ncdot.gov). See the last pages for further instruction. Online resources: •NCDOT Policy on Street and Driveway Access to North Carolina Highways: https://connect.ncdot.gov/projects/Roadway/RoadwayDesignAdministrativeDocuments/Policy%20on%20Street%20an d%20Driveway%20Access.pdf •NCDOT Policies and Procedures for Accommodating Utilities on Highway Rights of Way: https://connect.ncdot.gov/municipalities/Utilities/Pages/UtilitiesManuals.aspx •Electronic Forms Database: https://connect.ncdot.gov/Pages/default.aspx 1) a.Cover Letter Include contact information for applicant and engineer, including email address, mailing address, and phone number. Include the parcel number(s), description of all phases of the development and future land uses to be served by the permit, and a description of the adjoining land owned or controlled by the applicant. b.NCDOT Street and Driveway Access Permit Application (form downloadable via link below) https://connect.ncdot.gov/resources/BusinessForms/TEB-65-04.doc c.$50.00 Inspection Fee Per Access Point Attach to Permit Application form (not applicable for municipalities, churches, and schools) d.NPDES Stormwater Permit Compliance Certification (form downloadable via link below) https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/NPDESstatement.doc e.Verification of Compliance with Environmental Regulations (form downloadable via link below) https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/VCER-1.pdf f.Site Plans (to include the “Master Plan” of a tract even if only a small portion is being developed first) Additional site plan requirement details can be found in section 2 of this document. g.Design Plan Requirements for projects involving roadway improvements If roadway improvements are required as part of the permit, then roadway plans, pavement marking plans,signing plans, and traffic control plans will be required - See Section 6 for more information Y N n/a Engineering Studies The applicant may be required by the District Engineer to submit studies based on, but not limited to, the parameters outlined herein. If study requirements of the local government agency are more restrictive than the NCDOT requirements, then local government requirements will govern. However, this does not imply that the NCDOT is obligated to approve entrance designs that are too constrictive to allow smooth and safe traffic flow. All studies including, but not limited to, Traffic Impact Analyses (TIA), traffic signal studies, and drainage studies, must be prepared under the direct charge of and sealed by a North Carolina licensed Professional Engineer. Section 1: Requi red Documents |Required documents to accompany all Initial Driveway Application Submittals Please note that these are the minimum requirements of all driveway permit applications. All required documentation shall be submitted through the online portal as PDF files, with the exception of the Performance and Indemnity Bond and the $50 Inspection Fee(s), these should be mailed or delivered to 5501 Barbados Blvd, Castle Hayne, NC 28429. If a Traffic Impact Analysis and/or roadway improvements are deemed necessary as a condition of the permit, there may be additional submittal materials required. State of North Carolina | Department of Transportation | Division 3 | District 3 5501 Barbados Blvd, Castle Hayne, NC 28429 Form Updated 10/15/2021 (910) 398-9100 T NCDOT Permit #___________________ Y N n/a Section 1: Required Documents (continued) 2)Required documents to accompany all Driveway Applications PRIOR TO FINAL APPROVAL a.Site Plans One (1) digital copy (PDF) unless otherwise requested by the District Office. Additional site plan requirement details can be found in section 2 of this document. b.Performance and Indemnity Bond Information/Forms See last page of document for bond information and forms c.Performance and Indemnity Bond Amount 100% of the cost of the work within NCDOT Right-of-Way (R/W) based on the attached estimate determined by the applicant's engineer and approved by the District Engineer. Bond hold letter required for for municipalities, churches, and schools. See pages 101-105 in the Policies and Procedures for Accommodating Utilities on Highway Rights of Way for acceptable bond types d.Radius Encroachment Letter (if applicable) If driveway radius encroaches on the frontage of an adjacent property, a Radius Encroachment will be required e.Hold Harmless Letter (if applicable) If the Permit is within the limits of an active NCDOT project, a Hold Harmless letter from the NCDOT contractor will be required. If the project is in preconstruction, coordinate with the Department's Project Development Unit Section 2: General Site Plan Requirements | All site plans shall include and show, at a minimum, the items listed below Page numbers reference the NCDOT Policy on Street and Driveway Access to North Carolina Highways 1)Drawn to a scale of 20, 30, 40, or 50 feet per inch and the scale shall be shown 2)North arrow, vicinity map, date of plan, and date of most-recent revision if applicable 3)Contact information of applicant and engineer, including mailing address, phone number, and email address 4)Show R/W lines, highway control of access, and property lines 5)All existing utilities (including handholes) and easements 6)R/W width 7)Existing posted speed limit(s) and design speed limit(s) 8)Show all property lines, intersections, signals, signal loops, railroads, or crossovers within 500’ in all directions of the property lines of the proposed development 9)Show location of sidewalks, crosswalks, greenways, multi-use paths, curb ramps, railroads, bus stops, and any other relevant transportation facilities in the development area 10)Include a plan sheet showing full site build-out and land use 11)Buildings shown with “gross leasable area” 12)Width of property frontage 13)Distance from R/W to buildings and gasoline service islands 14)Distance from R/W to existing/proposed Edge of Pavement (EOP) (pages 32 & 34) 15)All streams, bridges, retaining walls, signs, or other fixed objects such as trees, utility poles, traffic signals, etc. Section 3: Driveway Plan Requirements | All driveway plans shall include and show, at a minimum, the items listed below 1)Provide comprehensive survey within the existing R/W on both sides of the road for a distance of 500’ in all directions from the development’s property lines. Provide additional hydraulic survey data to the nearest storm water inlet/outlet including ditch lines and storm water pipes, if located outside of the 500' distance. 2)Lane configurations and widths of all existing and proposed driveways, roadways, and adjacent roadways 3)All driveway widths (2-way: 20’ minimum, 36’ maximum | 1-way: 12’ minimum, 24’ maximum | with island: 14'ingress, 18' egress) (pages 50 & 77) 4)Driveway Profile - In shoulder sections, maintain minimum 2% fall from edge of travel way for required shoulder width distance Primary: 8’ minimum | Secondary: 6’ minimum 5)All existing and/or proposed driveway radii (20’ minimum, 50’ maximum, 30’ typical) (pages 34 & 51) In curb and gutter sections, use City of Wilmington flare (SD 3-03.3) - (see attached) In shoulder sections, show grades at the EOP and centerline 6)No curbing is allowed within NCDOT R/W along shoulder sections except as part of a driveway island (page 31) 7)Driveway angles of approach to existing roadway (90° preferred, 75°-90° required for 2-way driveways, 45°-90° allowed for right-in/right-out on a case-by-case basis) (page 51) 8)Driveway Profile (pages 42- 43) Y N n/a Y N n/a □□ □□ □ □ Y N n/a Y N n/a Y N n/a Y N n/a Section 3: Driveway Plan Requirements (continued) 9)Driveway Pavement Cross Section (to be in place from EOP to edge of R/W) Asphalt: 8” ABC stone and 1.5” S9.5B Concrete: 6” of concrete 10)Driveway Offset (driveway EOP to property line; page 75): Minimum: 20’ 11)Corner Clearance (radius point to radius point; page 52)Minimum: 50’ Desirable: 100’ or Municipal std. 12)Minimum 10’x70’ sight triangles at driveways (measured from and along the R/W line) (page 31) 13)Sight Distance (length of sight-distance in both directions shown for each driveway; pages 27-29) 14)Driveways should be aligned with existing opposing driveways or correct offset should be provided (pages 40-41) 15)Distance between driveways being requested (if applicable; page 51) 16)Minimum internal storage areas with specified queues (pages 31-33) 17)Minimum protected driveway stem(s) provided and indicated (pages 33-34) 18)Indicate any gated entrances (100’ minimum setback from R/W required) - traffic queuing study may be required | Section 6: Roadway Plan Requirements If off-site improvements are required, roadway plans shall show, at a minimum, the items below 1)Full width typical sections must be shown (paved shoulders to match the typical section of the adjacent roadway) 2)Minimum Asphalt Typical Section (for turn lanes and/or paved shoulders) Adjacent recently-completed or upcoming TIP projects w/ different typical sections may supersede those below •Primary Routes (US & NC) and Secondary Routes with Annual Average Daily Traffic (AADT) ≥10,000 5.5” B25.0C, 3” I19.0C, 1.5” S9.5C; any overlay of existing pavement is to be a minimum of 1.5” S9.5C •Secondary Routes with AADT<10,000 5.5” B25.0C, 1.5” S9.5B; any overlay of existing pavement is to be a minimum of 1.5” S9.5B 3)Pavement overlay is required if modification of existing pavement markings and/or lanes is necessary The grinding of pavement markings will not be allowed 4)Shoulder Widths (Paved + Unpaved) Primary: 8’ minimum | Secondary: 6’ minimum 5)Ditch Slopes - front and back slopes - minimum 3:1 or flatter 6)Indicate existing roadway grade 7)All taper lengths and deceleration lengths should be appropriately designed for the given design speed (page 78) 8)All turn lanes should be designed according to the Driveway Manual and Roadway Standard Drawings (page 79) See 1205.04 Sheets 1 & 2 and 1205.05 Sheet 1 of the Roadway Standard Drawings for details 9)Pavement marking and signing plans are required - plans must be approved by Division Traffic Services 10)Traffic control plans are required - Detailed phasing plans may be required based on project type and location 11)New and/or revised signal plans must be included for new installations and if signal modifications are required All signal plans must be reviewed and approved by Division Traffic Services and the Signal Design Unit. A Traffic Agreement must be completed to facilitate the review. Contact Division Traffic Services at (910) 341-2200. | Section 4: Drainag e Requirements All drainage features on NCDOT Right-of-Way shall adhere to, at a minimum, the items listed below Section 5: Internal Circ ulation Requirements |All internal circulation details shall adhere to, at a minimum, the items listed below 1)Interior driveway channelization stems Minimum 100’ from the ROW or at the discretion of the District Engineer 2)Traffic flow pattern 3)Traffic control devices 4)Pavement Markings Y N n/a Y N n /a Y N n/a Y N n/a Y N n/a Y N n/a Y N n/a Y N n/a 1)Pipe Cover Minimums (measured from top of pipe to subgrade) High Density Polyethylene (HDPE): 24” | Corrugated Aluminum (CAP): 12” | Reinforced Concrete (RCP): 12” 2)Pipe End Treatment (see Roadway Design Manual 5-20, B-2) Pipes ≤24" on multilane highways posted above 45mph require Parallel Pipe End Sections See 310.02 and 310.04 of the Roadway Standard Drawings for details Pipes >30" on multilane highways posted above 45mph require guardrail Pipes ≥36" require an endwall on the inlet end 3)All proposed Drainage is to be provided inside existing R/W. Otherwise, additional R/W or a permanently dedicated drainage easement will be required to accommodate the proposed project drainage 4)All sizes, types, and invert elevations of existing/proposed pipes and drainage structures must be shown(see Sec.3 #1 for survey requirements) 5)Provide spot elevations along frontage of driveway (at EOP and centerline) 6)Provide grades and spot elevations for existing and proposed ditches 7)Show how drainage will be accommodated along property frontage(District Engineer may require applicant to provide drainage calculations when warranted) C/L EOTEOP P/L R/WR/W R/W EOP EOP EOP EOP NTS R/W P/L DRAINAGE FLOW DRAINAGE FLOW DRAINAGE FLOW SHOULDER WIDTH SHOULDER WIDTH SHOULDER WIDTH SHOULDER WIDTH S IGHT T R IANG LE 10 ' BY 70 'S I GHT T R I ANGL E10' B Y 70' DRIVEWAY RR MIN. 30'MIN. 30' NO ROADWAY IMPROVEMENT COMMERCIAL DRIVEWAY WITH NORMAL CROWN ROADWAY 6" LOWER THAN THE EDGE OF PAVEMENTMIN 2% FALL AWAY or 20' AWAY FROM THE PROPERTY LINEDRIVEWAY SHALL BE LOCATED AT LEAST PIPE/TYPE/SIZE WIDTH CON CR ET E /ASP HA LT LOCAL NAME ROAD POSTED SPEED ( ) MPH WIDTH WIDTHSR NUMBER SITE ADDRESS:TAX PARCEL # 20191115 PARALLEL END S.D. 310.02 INVERT ELEVATION PARALLEL END S.D. 310.02 INVERT ELEVATION 20' AWAY FROM THE PROPERTY LINEDRIVEWAY SHALL BE LOCATED AT LEAST OR 500' OF XYZ SURVEY DATA PAST THE PROPERT LINENEAREST OUTFALL ELEVATION OR 500' OF XYZ SURVEY DATA PAST THE PROPERT LINENEAREST OUTFALL ELEVATION OPEN SPACE & STORMWATER POND AREA PROPOSED ENTRANCE FEATURE(BY OTHERS) PROPOSEDOPEN SPA C E 10' M.U.P. NC GRID N A D 8 3 ( N S R S 2 0 1 1 ) WETLAND AREA FLAGGED BY SOUTHERNENVIRONMENTAL GROUP SITE DATA PARCEL ID:R04300-003-025-000,R04300-003-057-000,R04300-003-026-010 CURRENT ZONING:R-5 (Z25-06) PROJECT ADDRESS:6425, 6437 GORDON RD.& 1927 GORDON ACRES DR. WILMINGTON, NC 28411 CURRENT OWNER:HERON COVE DEVELOPMENT, LLCPO BOX 538WRIGHTSVILLE BEACH, NC 28480 TOTAL ACREAGE IN PROJECT BOUNDARY: ±473,493 S.F. (±10.87 AC.) HERON COVE 6425, 6437 GORDON RD. & 1927 GORDON ACRES DR WILMINGTON, NORTH CAROLINA CIVIL ENGINEER INTRACOASTAL ENGINEERING, PLLC5725 OLEANDER DR. SUITE E-7 WILMINGTON, NC 28403PHONE: 910-859-8983CONTACT: CHARLES CAZIER SURVEYOR BATEMAN CIVIL SURVEY COMPANY30 COVIL AVE. WILMINGTON, NC 28403PHONE: 910-772-9113CONTACT: CARL CORPUS CLIENT HERON COVE DEVELOPMENT, LLCPO BOX 538 WRIGHTSVILLE BEACH, NC 28480PHONE: 910-399-5688CONTACT: CRAIG JOHNSON SHEET NO. DESCRIPTION C-0 EXISTING CONDITIONS, DEMO & TREE REMOVAL PLAN C-1 SITE, GRADING, DRAINAGE & STORMWATER PLAN C-2 UTILITIES PLANC-3 SEDIMENTATION & EROSION CONTROL PLANC-4 SANITARY SEWER PLAN/PROFILEC-5 SANITARY SEWER PLAN/PROFILEC-6 GENERAL DETAILS C-7 STORMWATER DETAILS C-8 SEDIMENTATION & EROSION CONTROL DETAILSC-9 NCDOT DETAILSC-10 UTILITY DETAILSC-11 UTILITY DETAILS C-12 NCG01 NOTES VICINITY MAP (NOT TO SCALE): GOR D O N R D . SITE GOR D O N A C R E S D R . DAN I E L B O O N E T R L . DAIS Y L E E D R . M I L I T A R Y C U T O F F E X T . MISS I O N H I L L S D R . PAT S Y L N . OG D E N P A R K D R . 200'100'50'100'0' Scale: 1"=100' 40 40 35 35 35 35 35 35 35 35 35 3535 40 40 30' P.U.E. MA T C H L I N E 30' PROP. P.D.E. 63' 4 4 CLUSTER MAILBOX(DESIGN BY OTHERS) 2 18" FESINV: 33.5 18" FESINV: 32.5 18" RCP CI#8RIM: 39.25INV: 36.0 APP R O X . L O C A T I O N E X . W A T E R M A I N 38.0 18" R C P HERON COVE DRIVEPROP. 45' PRIVATE R.O.W.& PUBLIC U.E. 38.5 40.5 18 " R C P NCDOT HEADWALLW/ 20' X 25' X 24"RIP-RAP LINEDENTRANCE 10' M.U.P. 37.4 38.520' 87' R35 ' R35' MATCH EX. ASPHALT±37.5 37.1 CI#5RIM: 37.25INV: 34.15 CI#10RIM: 37.25INV: 33.2 27.5 WETLAND AREA FLAGGED BY SOUTHERNENVIRONMENTAL GROUP 50 ' 50' 41.018" R C P 24" RCP 43 41 3640 41 39 38 37 36 37 38 38 37 39 37 36 20' PERIPHERY SETBACK(TYP) 20' PERIPHERY SETBACK(TYP) 24" FESW/6'X10'X12" EDINV: 33.0 CI#4RIM: 37.0INV: 33.9 CI#3RIM: 37.0INV: 34.35 41.5 41.0 CI#1RIM: 37.0INV: 34.4 CI#2RIM: 37.0INV: 34.20 41.65 41.65 (60' PRIVATE R/W) SIREN ACTIVATEDGATE AT BOUNDARY MA T C H L I N E 63' 4 9'18'4 4 STER MAILBOXSIGN BY OTHERS) CI#8RIM: 39.25INV: 36.0 CI#12RIM: 40.0INV: 37.15 CI#13RIM: 40.25INV: 37.5 24" RCP 30" RCP 42.0 10' PROP. PEDESTRIAN ACCESS& UTILITY EASEMENT 30" RCP 42.25 APPROX. LOCATION EX. 8" SEWER MAIN NC GRID N A D 8 3 ( N S R S 2 0 1 1 ) 41.0 HERON COVE DRIVEPROP. 45' PRIVATE R.O.W.& PUBLIC U.E. 4343 43 43 4342 42 42 43 43 43 43 43 43 43 43 43 43 43 43 42 43 43 43 41 20' PERIPHERY SETBACK(TYP) CI#17RIM: 41.25INV: 35.4CI#16RIM: 40.2515" INV. IN: 37.4INV: 36.15 41.5 41.5 41.0 42.0 41.5 41.65 41.65 C-1 2 1" = 60' REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: CLIENT INFORMATION: VICINITY MAP (NOT TO SCALE): 2025-009 CLIENT INFORMATION: Heron Cove Development, LLC PO Box 538Wrightsville Beach, NC 28480 Ph. 910-399-5688 OF 13 JAE CDC CDC 24x36 9/29/2025 PREL I M I N A R Y DRAW I N G D O N O T U S E FOR C O N S T R U C T I O N GOR D O N R D . SITE GORD O N A C R E S D R . DANI E L B O O N E T R L . DAISY L E E D R . MI L I T A R Y C U T O F F E X T . MISSI O N H I L L S D R . PATS Y L N . OGD E N P A R K D R . PE R F O R M A N C E R E S I D E N T I A L GR A D I N G , D R A I N A G E , & S I T E PL A N PROPERTY LINERIGHT OF WAYADJOINERSPROPOSED LOTLINEEX. EDGE OF PAVEMENT PROPOSED OPEN SPACE FLOW DIRECTION PROPOSED SPOT ELEVATION LEGEND SITE DATA PARCEL ID:R04300-003-025-000,R04300-003-057-000,R04300-003-026-010 CURRENT ZONING:R-5 (Z25-06) PROJECT ADDRESS:6425, 6437 GORDON RD.& 1927 GORDON ACRES DR. WILMINGTON, NC 28411 CURRENT OWNER:HERON COVE DEVELOPMENT, LLCPO BOX 538WRIGHTSVILLE BEACH, NC 28480 TOTAL ACREAGE IN PROJECT BOUNDARY: ±473,493 S.F. (±10.87 AC.) MAXIMUM DENSITY: 8 D.U./ACRE(8 X 10.87=87 D.U. ALLOWED) PROPOSED UNITS: 67 LOTS MAXIMUM BUILDING HEIGHT: 40' REQUIRED PERIMETER SETBACK: 20' TOTAL OPEN SPACE REQUIREMENT: (20% OF SITE AREA)REQUIRED 10.87 AC. X 20%= 2.17 ACPROVIDED: 3.25 AC ON-SITE IMPERVIOUS AREAS:67 LOTS 120,600 S.F. (1,800 S.F. Per Lot)FUTURE OUTPARCEL 13,200 S.F.ASPHALT ROAD 53,900 S.F.CONCRETE SIDEWALK, C&G, ETC. 31,670 S.F.FUTURE (RECREATION AREA) 8,540 S.F.TOTAL 227,910 S.F. (48.13%) PROPOSED SEWER AND WATER DEMAND:SEWER: (67) 3 BDRM RES. @ 225 GAL/RES. = 15,075 GPDWATER: (67) 3 BDRM RES. @ 400 GAL/RES. = 26,800 GPD ESTIMATED TRIP GENERATION (Per Trip Generation Manual):67 RESIDENTIAL D.U. (ITE CODE 210)AM PEAK: 47 PM PEAK: 63 120'60'30'60'0' Scale: 1"=60' 42.0 FIRE & SAFETY NOTES:1. PARKING AND LANDSCAPING CANNOT BLOCK FIRE HYDRANTS.2. ALL WEATHER ACCESS ROAD MUST BE MAINTAINED AROUND CONSTRUCTION SITE ATALL TIMES.3.ALL FIRE HYDRANTS MUST BE INSTALLED WITH 5 INCH STORZ QUICK CONNECTSON A 4.5 INCH STEAMER IN COMPLIANCE WITH NHC FIRE SERVICEREQUIREMENTS. CZD CONDITIONS (Z25-06):1. THE PROJECT WILL INCLUDE EMERGENCY ONLY ACCESS TO DANIEL BOONE TRAIL.2. THE PROJECT WILL INCLUDE A MINIMUM OF ONE-CAR GARAGE WITH EACH HOME ANDABILITY TO PARK TWO CARS IN THE DRIVEWAY OF EACH HOME.3. THE PROJECT WILL PROVIDE A SIX-FOOT FENCE AT THE REAR OF EACH LOT IN THEDEVELOPMENT.4. TWO TREES AT LEAST 2 INCHES IN DIAMETER AT BREAST HEIGHT WILL BE PLANTED ONEACH LOT, TO BE MAINTAINED BY THE HOA THROUGH A LANDSCAPING EASEMENT ONEACH LOT. TREE MAINTENANCE AND PRESERVATION WILL BE INCLUDED IN THECOVENANTS WHICH ARE SUBJECT TO COUNTY REVIEW BEFORE RECORDING OF FINALPLAT.5. THE 18-INCH OAK TREE IN THE MIDDLE OF THE INTERNAL ROAD, AROUND WHICH THEROAD HAS BEEN RECONFIGURED, WILL BE PRESERVED ON THE SITE.6. THERE WILL BE TWO 10-FOOT IN WIDTH BICYCLE AND PEDESTRIAN ACCESS EASEMENTS INTHIS DEVELOPMENT, CONNECTING DANIEL BOONE TRAIL AND GORDON ACRES DRIVE.7. A PUBLIC UTILITY EASEMENT MEETING THE MINIMUM STANDARDS OF CFPUA FOR WATERAND SEWER INFRASTRUCTURE SHALL BE DEDICATED ALONG THE BICYCLE ANDPEDESTRIAN EASEMENT CONNECTION TO GORDON ACRES DRIVE AT THE TIME THE FINALPLAT IS RECORDED WITH THE REGISTER OF DEEDS.8. EXISTING TREES IN THE SITE'S OPEN SPACE THAT DO NOT IMPACT REQUIRED LANDGRADING OR OTHER IMPROVEMENTS AND FUTURE AMENITIES AS IDENTIFIED IN THEREQUIRED TREE REMOVAL PERMIT WILL BE PRESERVED.9. MAINTENANCE OF THE FENCE REQUIRED IN CONDITION #3 ABOVE WILL BE THERESPONSIBILITY OF THE PROPERTY OWNER AND INCLUDED IN THE HOMEOWNER'SASSOCIATION COVENANTS, TO BE RECORDED WITH THE FINAL PLAT WITH THE NEWHANOVER COUNTY REGISTER OF DEEDS. THE PLAT WILL NOTE THAT THIS STUDY ISNON-REGULATORY.10. THE 2025 NEW HANOVER COUNTY FLOODPLAIN ADVISORY STUDY SHALL BE SHOWN ONTHE FINAL PLAT FOR THIS DEVELOPMENT, NOTING ON LOTS 7 & 59 THE FLOOD RISK ASPART OF THAT STUDY, AND SHALL BE RECORDED WITH THE FINAL PLAN WITH THE NEWHANOVER COUNTY REGISTER OF DEEDS. THE PLAT WILL NOTE THAT THIS STUDY ISNON-REGULATORY. DEVELOPMENT NOTES:1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH THE NEW HANOVER COUNTY UNIFIEDDEVELOPMENT ORDINANCE2. PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS.3. RUNOFF FROM ALL IMPERVIOUS SURFACES TO BE DIRECTED TO STORMWATER FACILITY4. MIN. 10' SEPARATION BETWEEN BUILDINGS REQUIRED FOR PERFORMANCE RESIDENTIAL.5. PROPOSED STREET TO MEET NEW HANOVER COUNTY SUBDIVISION ORDINANCE MINIMUMSTANDARDS FOR PRIVATE STREETS.6. DEVELOPER IS RESPONSIBLE FOR STREET SIGN AND STREET LIGHTING INSTALLATION INACCORDANCE WITH NEW HANOVER COUNTY SUBDIVISION ORDINANCE.7. ALL OPEN SPACES, COMMON AREAS, PRIVATE ROW'S, EASEMENTS, AND DRAINAGE POND AREAS TOBE MAINTAINED BY THE DEVELOPER UNTIL THEY'RE TURNED OVER TO THE HOME OWNERSASSOCIATION.8. DEVELOPER TO PROVIDE MAILBOX KIOSK AND PAD IN OPEN SPACE AREA.9. DEVELOPER TO PROVIDE ONE FRONT YARD AND ONE BACKYARD TREE FOR EACH LOT ANDPROTECTED PER DEED RESTRICTIONS. A 5' FRONT AND REAR LANDSCAPE EASEMENT TO BEPROVIDED ON EACH LOT FOR THIS PROVISION. UTILITY NOTES:1. EXISTING WATER AND SANITARY SEWER SERVICES ARE CURRENTLY AVAILABLE TOTHE SITE FROM CAPE FEAR PUBLIC UTILITY AUTHORITY PUBLIC MAINS.2. ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS &TELEPHONE SHALL BE INSTALLED UNDERGROUND.3. ALL WATER & SEWER UTILITIES TO BE INSTALLED PER CFPUA TECHNICALSPECIFICATIONS & STANDARDS.4. PROJECT SHALL COMPLY WITH CFPUA CROSS CONNECTION CONTROLREQUIREMENTS. WATER METER(S) CANNOT BE RELEASED UNTIL ALLREQUIREMENTS ARE MET AND N.C.D.E.N.R. HAS ISSUED THEIR "FINAL APPROVAL.".CALL 332-6558 FOR INFORMATION.5. ANY BACKFLOW PREVENTION DEVICES REQUIRED BY THE CFPUA WILL NEED TO BEON THE LIST OF APPROVED DEVICES BY USCFCCCHR OR ASSE.6.IF CONTRACTOR DESIRES CFPUA WATER FOR CONSTRUCTION, HE SHALL APPLY INADVANCE FOR THIS SERVICE AND MUST PROVIDE A REDUCED PRESSURE ZONE (RPZ)BACKFLOW PREVENTION DEVICE ON THE DEVELOPER'S SIDE OF THE WATER METERBOX.7. WHEN PVC WATER MAINS AND SERVICES ARE PROPOSED, THE PIPES ARE TO BEMARKED WITH NO. 10 INSULATED, SINGLE-STRAND COPPER WIRE INSTALLED &STRAPPED TO THE PIPES WITH DUCT TAPE. THIS IS TO BE ACCESSIBLE IN ALLVALVES AND METER BOXES TO AID IN FUTURE LOCATION OF FACILITIES.8. SEWER GUARDS REQUIRED AT ALL MANHOLES. STAINLESS STEEL SEWER GUARDSREQUIRED AT MANHOLES LOCATED IN TRAFFIC AREAS.9. SERVICES SHALL BE PERPENDICULAR TO MAIN AND TERMINATE AT RIGHT-OF-WAYLINE. SERVICES IN CUL-DE-SACS ARE REQUIRED TO BE PERPENDICULAR OR MUSTORIGINATE IN MANHOLE AND TERMINATE AT RIGHT-OF-WAY LINE.10. ALL SERVICES TYING INTO DUCTILE IRON MAINS SHALL BE CONSTRUCTED OF CLASS50 D.I.P. WITH PROTECTO 401 CERAMIC EPOXY LINING.11. MINIMUM 10' UTILITIES EASEMENT PROVIDED ALONG THE FRONTAGE OF ALL LOTSAND AS SHOWN FOR NEW DEVELOPMENTS.12. NO FLEXIBLE COUPLINGS SHALL BE USED.13. ALL STAINLESS STEEL FASTENERS SHALL BE 316.14. THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OFEXISTING UTILITIES DURING CONSTRUCTION. CALL NC811 AT 811 OR 1-800-632-4949.CONTRACTOR IS RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ANYUTILITIES, CURB & GUTTER, PAVEMENT, ETC. THAT MAY BE BE DAMAGED DURINGCONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIRED TO AT LEAST THE QUALITYOR WORKMANSHIP FOUND IN THE ORIGINAL ITEM.14. SHOULD ADDITIONAL SERVICES BE LOCATED DURING CONSTRUCTION, THEY MUSTEITHER BE UTILIZED OR ABANDONED. 40 40 35 35 35 35 35 35 35 35 35 3535 40 40 30' P.U.E. LO C A T I O N E X . S S M A I N MA T C H L I N E CLUSTER MAILBOX(DESIGN BY OTHERS) APP R O X . L O C A T I O N E X . W A T E R M A I N HERON COVE DRIVEPROP. 45' PRIVATE R.O.W.& PUBLIC U.E. SSMH #2B SSMH #1B 8" SS MAIN 8" S S M A I N 10' M.U.P. 27.5 WETLAND AREA FLAGGED BY SOUTHERNENVIRONMENTAL GROUP 8" SS MAINSSMH #2A 43 41 3640 41 39 38 37 36 37 38 38 37 39 37 36 8" SS MAIN SSMH #1C MA T C H L I N E USTER MAILBOXESIGN BY OTHERS) APPROX. LOCATION EX. 8" SEWER MAIN TIE TO EX. 6" WATERMAIN(1) 6" CUT-IN TEE(1) 6" X 8" INCREASER(1) 8" G.V. (1) 8" TEE(2) 8" G.V. 8" C-900 PVC W. MAIN(36" MIN. BURY) NC GRID N A D 8 3 ( N S R S 2 0 1 1 ) HERON COVE DRIVEPROP. 45' PRIVATE R.O.W.& PUBLIC U.E. 4343 43 43 4342 42 42 43 43 43 43 43 43 43 43 43 43 43 43 42 43 43 43 41 SSMH #1C C-2 3 1" = 60' REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: CLIENT INFORMATION: VICINITY MAP (NOT TO SCALE): 2025-009 CLIENT INFORMATION: Heron Cove Development, LLC PO Box 538Wrightsville Beach, NC 28480 Ph. 910-399-5688 OF 13 JAE CDC CDC 24x36 9/29/2025 PREL I M I N A R Y DRAW I N G D O N O T U S E FOR C O N S T R U C T I O N GOR D O N R D . SITE GORD O N A C R E S D R . DANI E L B O O N E T R L . DAISY L E E D R . MI L I T A R Y C U T O F F E X T . MISSI O N H I L L S D R . PATS Y L N . OGD E N P A R K D R . PROPERTY LINERIGHT OF WAYADJOINERSPROPOSED LOTLINEEX. EOPPROP. EASEMENTCENTER LINEWATERLINESANITARY SEWER LINE FIRE HYDRANT ASSY SAMPLING STATION GATE VALVE LEGEND PE R F O R M A N C E R E S I D E N T I A L UT I L I T I E S P L A N SITE DATA PARCEL ID:R04300-003-025-000,R04300-003-057-000,R04300-003-026-010 CURRENT ZONING:R-5 (Z25-06) PROJECT ADDRESS:6425, 6437 GORDON RD.& 1927 GORDON ACRES DR. WILMINGTON, NC 28411 CURRENT OWNER:HERON COVE DEVELOPMENT, LLCPO BOX 538WRIGHTSVILLE BEACH, NC 28480 TOTAL ACREAGE IN PROJECT BOUNDARY: ±473,493 S.F. (±10.87 AC.) MAXIMUM DENSITY: 8 D.U./ACRE(8 X 10.87=87 D.U. ALLOWED) PROPOSED UNITS: 67 LOTS PROPOSED SEWER AND WATER DEMAND:SEWER: (67) 3 BDRM RES. @ 225 GAL/RES. = 15,075 GPDWATER: (67) 3 BDRM RES. @ 400 GAL/RES. = 26,800 GPD 120'60'30'60'0' Scale: 1"=60' UTILITY NOTES:1. EXISTING WATER AND SANITARY SEWER SERVICES ARE CURRENTLY AVAILABLE TO THE SITEFROM CAPE FEAR PUBLIC UTILITY AUTHORITY PUBLIC MAINS.2. ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS & TELEPHONE SHALL BEINSTALLED UNDERGROUND.3. ALL WATER & SEWER UTILITIES TO BE INSTALLED PER CFPUA TECHNICAL SPECIFICATIONS &STANDARDS.4. PROJECT SHALL COMPLY WITH CFPUA CROSS CONNECTION CONTROL REQUIREMENTS. WATERMETER(S) CANNOT BE RELEASED UNTIL ALL REQUIREMENTS ARE MET AND N.C.D.E.N.R. HASISSUED THEIR "FINAL APPROVAL.". CALL 332-6558 FOR INFORMATION.5. ANY BACKFLOW PREVENTION DEVICES REQUIRED BY THE CFPUA WILL NEED TO BE ON THE LISTOF APPROVED DEVICES BY USCFCCCHR OR ASSE.6.IF CONTRACTOR DESIRES CFPUA WATER FOR CONSTRUCTION, HE SHALL APPLY IN ADVANCE FORTHIS SERVICE AND MUST PROVIDE A REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTIONDEVICE ON THE DEVELOPER'S SIDE OF THE WATER METER BOX.7. WHEN PVC WATER MAINS AND SERVICES ARE PROPOSED, THE PIPES ARE TO BE MARKED WITHNO. 10 INSULATED, SINGLE-STRAND COPPER WIRE INSTALLED & STRAPPED TO THE PIPES WITHDUCT TAPE. THIS IS TO BE ACCESSIBLE IN ALL VALVES AND METER BOXES TO AID IN FUTURELOCATION OF FACILITIES.8. SEWER GUARDS REQUIRED AT ALL MANHOLES. STAINLESS STEEL SEWER GUARDS REQUIRED ATMANHOLES LOCATED IN TRAFFIC AREAS.9. SERVICES SHALL BE PERPENDICULAR TO MAIN AND TERMINATE AT RIGHT-OF-WAY LINE.SERVICES IN CUL-DE-SACS ARE REQUIRED TO BE PERPENDICULAR OR MUST ORIGINATE INMANHOLE AND TERMINATE AT RIGHT-OF-WAY LINE.10. ALL SERVICES TYING INTO DUCTILE IRON MAINS SHALL BE CONSTRUCTED OF CLASS 50 D.I.P.WITH PROTECTO 401 CERAMIC EPOXY LINING.11. MINIMUM 10' UTILITIES EASEMENT PROVIDED ALONG THE FRONTAGE OF ALL LOTS AND ASSHOWN FOR NEW DEVELOPMENTS.12. NO FLEXIBLE COUPLINGS SHALL BE USED.13. ALL STAINLESS STEEL FASTENERS SHALL BE 316.14. THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIESDURING CONSTRUCTION. CALL NC811 AT 811 OR 1-800-632-4949. CONTRACTOR IS RESPONSIBLEFOR THE REPAIR AND REPLACEMENT OF ANY UTILITIES, CURB & GUTTER, PAVEMENT, ETC. THATMAY BE BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIRED TO ATLEAST THE QUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM.14. SHOULD ADDITIONAL SERVICES BE LOCATED DURING CONSTRUCTION, THEY MUST EITHER BEUTILIZED OR ABANDONED. MEMORANDUM To: New Hanover County Technical Review Committee Date: October 9, 2025 Subject: Heron Cove NCDOT Projects: • U-6202: Gordon Road Widening from US-17 (Market Street) to I-40 is currently set to begin construction in 2025. Project identified as close to 8% complete per NCDOT Division 3 September project updates. Project completion has not been determined. The site location is in direct proximity to this project. WMPO 2045 MTP Projects: • U-6202 – Is also in the 2045 MTP New Hanover County Projects: • N/A TIA: Based on the 11th edition ITE Trip Generation Manual, a TIA is not required. Land Use (ITE Code) Intensity Unit 24 Hour Volumes AM Peak Hour Trips PM Peak Hour Trips Single Family Attached (215) 67 Dwelling Units 460 29 36 Pandion Drive – Major Subdivision – TRC Review Page | 1 To: Lonnie Ellisor, Pulte Group (Lonnie.ellisor@PulteGroup.com) From: Zach Dickerson, Senior Planner Date: November 5, 2025 TRC Review PID#: R02900-002-008-005 Egov# SUBPP-25-0029 Subject: Pandion Drive- Preliminary Plan TRC Review Technical Review Committee (TRC) General Information The TRC is a staff-level group of local government officials that reviews projects for compliance with the local regulations administered by each respective review agency. Voluntarily participating state agencies may also provide comments. And general information and non-binding recommendations about the site may also be provided by government agencies. The TRC meetings are considered staff meetings and are not public hearings. The TRC meeting is an opportunity for applicants to speak with county staff and any voluntarily participating state or federal agencies about the review comments they have been provided. No voting is involved in the TRC process, and no final approvals or denials are made at the TRC meetings. Following the TRC meeting, applicants are responsible for updating their plans to address review comments. Those revised plans need to be resubmitted to the assigned case planner. The case planner will facilitate additional reviews until all comments have been addressed, and the necessary departments have stated the plans comply with the applicable minimum requirements for development. Following any future TRC approval, the project is required to obtain additional permits to include a zoning compliance permit for the site. Applicants are also responsible for coordinating with state and federal agencies for compliance with any additional requirements. Any activity on the property that is not approved as part of the TRC review and zoning compliance permit will be considered a violation of the UDO and subject to enforcement action under Article 12 Violations and Enforcement. Pandion Drive – Major Subdivision – TRC Review Page | 2 The following comments have been received for the November 5, 2025, TRC meeting. Additional comments may be made upon further review of subsequent revisions. Planning, Zach Dickerson 910-798-7450 Compliance with local zoning requirements 1. General Comments a. The zoning is R-15, single-family housing proposed. b. Is this subdivision intended to be part of the Scotts Hill Village neighborhood? Or a completely separate development? c. This is proposed as a performance residential subdivision. i. Density for Performance Residential: 2.5 dwelling units per acre in the R-15 zoning district. ii. Need to show density calculations. Example: 1. Total site acreage = 20.93 acres 2. Zoning District allows maximum 2.5 dwelling units per acre under performance residential subdivision. 3. Developable site acreage * zoning density = 52 dwelling units d. Staff recommend including the location of traffic calming devices on the preliminary plans. Installation of traffic calming devices are not required, but including potential locations on the plan ensures the future HOA / owners will have the opportunity to install them without conducting a traffic study. 2. UDO Section 5.1, Parking and Loading a. Single-family dwelling units require a minimum of two parking spaces per unit. b. Please note parking requirements on site plan. 3. UDO Section 5.2, Traffic, Access and Connectivity a. Please note that no building permit for any structure shall be issued which requires NCDOT approval for a Driveway Permit until NCDOT has issued the permit approval. Evidence of approval shall accompany the application for building permit. 4. UDO Section 5.3, Tree Retention a. Note: Land disturbance permits can be issued by county Engineering before a Tree Removal Permit is approved by Planning. However, any trees removed before the Pandion Drive – Major Subdivision – TRC Review Page | 3 Tree Removal Permit is issued may result in enforcement action under Section 5.3.2 of the Unified Development Ordinance to include prohibiting any development of the site for 3 to 5 years. b. Please note that because New Hanover County does not require a Tree Removal Permit for residential less than one acre in size, it does not require mitigation for tree removal on future lots in residential subdivisions that are less than one acre in size. c. It does, however, require potential mitigation for trees located in infrastructure areas, such as the road and stormwater pond. d. This can be edited for the tree removal permit. Is there a numbered tree chart? Something like this that corresponds to the tree survey itself: 5. UDO Section 5.4, Landscaping and Buffering a. Landscaping and buffering are only required for the amenity areas. Per this site plan it does not appear there is a planned amenity building- please confirm. 6. UDO Section 5.5, Lighting a. Please note under 5.5.2.A that a lighting plan is not required for single-family residential projects and the county does not require streetlights, however a lighting plan is required for any amenity area. 7. UDO Section 5.6, Signs a. Will there be any neighborhood entrance signs? If so, please indicate the location on this site plan and ensure that they will not cause any visibility issues at the intersection b. For any signs on the site, a separate sign permit must be submitted and reviewed by the county for compliance with Section 5.6 of the UDO for standards at or after the submittal of the separate zoning compliance and construction permits for the primary building or use. Pandion Drive – Major Subdivision – TRC Review Page | 4 8. UDO Section 5.7, Conservation Resources a. Per the New Hanover County Conservation Resource map, there are no Conservation Resources on this property. 9. UDO Section 5.8, Open Space Requirements a. Total site acreage is 20.93 acres. b. Performance residential developments require a minimum 20% open space. c. 20% * 20.93 = 4.19 acres of open space. d. Site plan proposes 4.34 acres of open space, 21%. e. Are there any planned pedestrian easements or infrastructure to the open space behind lots 1-8? This might make the open space more accessible to residents. 10. UDO Article 6, Subdivision Design and Improvements. a. Sidewalks noted as 5’ in width and along one side of the street, as required in R-15. All good. b. Are there sidewalks along this portion of Pandion Drive? If not, they will need to be installed. c. Block length is ok, thanks! d. Links and nodes ratio is ok, thanks! 11. UDO Article 9, Flood Damage Prevention a. There are portions of this site that are in the floodplain, but only the far eastern reaches of lots 49-52. Pandion Drive – Major Subdivision – TRC Review Page | 5 NHC Fire Services, David Stone 910-798-7458 Compliance with the NC Fire Code 1. Please annotate where any proposed or existing fire hydrants will be to serve the homes on Pandion Drive. NHC Engineering, Galen Jamison 910-798-7072 Stormwater management and land disturbance 1. A County stormwater and land disturbing permit issued by the County is required for this project. Please digitally submit the permit applications documentation with requisite review fees to the COAST online permit portal (https://newhanovercountync- energovpub.tylerhost.net/apps/selfservice#/home). Applicable forms can be found at https://www.nhcgov.com/251/Stormwater-Permitting and https://www.nhcgov.com/249/Sediment-Erosion-Controlhowever. 2. Please contact the State for their stormwater permit requirements. It is anticipated a new high density permit will be required. 3. Routing of the impervious drinage from Lot 52 appears to be challenging. It appears a conveyance measure may be required to ensure the impervious is directed to the SCM. 4. This parcel qualifies for an exemption to the County’s pre and post storm attenuation requirements should it be design in accordance with the City and County’s Low Impact Design (LID) Manual (http://laserfiche.nhcgov.com/weblink/0/edoc/3273331/LID-Manual.pdf). Please provide requisite documentation for compliance with LID manual and a variance request in accordance with NHC UDO, Section 7.12 during the County stormwater permitting process. As the subdivision is developed and impervious area added, each parcel will need submit similar documents as part of the building permit application and it’s site plan requirements. NHC Environmental Health, Dustin Fenske 910-798-6732 Septic tanks and wells 1. Site plan reflects connection to public water and sewer. Proposed infrastructure does not violate setbacks to surrounding properties’ well or septic systems. Pandion Drive – Major Subdivision – TRC Review Page | 6 NHC Addressing, McCabe Watson 910-798-7068 Street naming and property address 1. Road A and B shall assume the names of the streets they align with. Road A – Sidbury Park Lane. Road B- Tiger Lily Place. 2. Please contact me for address assignment following TRC approval. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 Public water and sewer 1. CFPUA TRC Comments provided are preliminary comments only. 2. CFPUA is moving toward becoming paperless. When ready to submit plan review package, upload all documents to https://www.cfpua.org/FormCenter/Engineering-3/Engineering- Plan-Review-103. 3. CFPUA water and sewer available via a mainline extension. 4. Capacity is dependent on the analysis of the pipe collection system (gravity and force mains). 5. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE Application Form and a Preliminary Plan, this determination does not guarantee capacity. 6. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the Authority. NCDOT, Nick Drees 910-343-3915 Driveway access and state road improvements 1. No comments. WMPO, Luke Hutson 910-473-5130 New Hanover County contracted traffic engineering services comments: 1. Comments attached. Pandion Drive – Major Subdivision – TRC Review Page | 7 Project information also provided to the following state agencies and non-regulatory local agencies for their awareness: New Hanover County Emergency Management New Hanover County Schools NC Department of Environmental Quality (DEQ) NC DEQ Division of Coastal Management NC DEQ Division of Energy, Mineral, and Land Resources New Hanover County Sustainability Manager New Hanover County Soil & Water Conservation Army Corps of Engineers MEMORANDUM To: New Hanover County Technical Review Committee Date: October 9, 2025 Subject: Pandion Drive Subdivision NCDOT Projects: • N/A WMPO 2045 MTP Projects: • N/A New Hanover County Projects: • N/A TIA: Based on the 11th edition ITE Trip Generation Manual, a TIA is not required Land Use (ITE Code) Intensity Unit 24 Hour Volumes AM Peak Hour Trips PM Peak Hour Trips Single Family Detached Housing (210) 52 Dwelling Units 553 41 54 SB Cottages – Major Subdivision – TRC Review Page | 1 To: Wes Reynolds, SB Cottages Investments, LLC, wreynolds@mc1.biz From: Robert Farrell, Development Review Supervisor Date: October 6, 2025 PID#: R08518-001-001-000, R08518-001-014-003, R08518-001-014-002, R08518-001-014-001 Egov# SUBPP-25-0030 Subject: SB Cottages – Preliminary Plan TRC Review Technical Review Committee (TRC) General Information The TRC is a staff-level group of local government officials that reviews projects for compliance with the local regulations administered by each respective review agency. Voluntarily participating state agencies may also provide comments. And general information and non-binding recommendations about the site may also be provided by government agencies. The TRC meetings are considered staff meetings and are not public hearings. The TRC meeting is an opportunity for applicants to speak with county staff and any voluntarily participating state or federal agencies about the review comments they have been provided. No voting is involved in the TRC process, and no final approvals or denials are made at the TRC meetings. Following the TRC meeting, applicants are responsible for updating their plans to address review comments. Those revised plans need to be resubmitted to the assigned case planner. The case planner will facilitate additional reviews until all comments have been addressed, and the necessary departments have stated the plans comply with the applicable minimum requirements for development. Following any future TRC approval, the project is required to obtain additional permits to include a zoning compliance permit for the site. Applicants are also responsible for coordinating with state and federal agencies for compliance with any additional requirements. Any activity on the property that is not approved as part of the TRC review and zoning compliance permit will be considered a violation of the UDO and subject to enforcement action under Article 12 Violations and Enforcement. The following comments have been received for the November 5, 2025, TRC meeting. Additional comments may be made upon further review of subsequent revisions. SB Cottages – Major Subdivision – TRC Review Page | 2 Planning, Robert Farrell 910-798-7164 Compliance with local zoning requirements 1. General Comments a. Property was rezoned to Conditional R-5 in 2023 as Z23-14. The rezoning was approved with the following 5 conditions. Please include these conditions on one of the preliminary plan pages: i. The project as shown on the submitted site plan shall be developed with water and sewer connections to a private wastewater system. Private wells and septic systems are not allowed for residential development as contemplated on the site plan. ii. As identified on the site plan, certain existing trees onsite will not be removed. iii. The zoning approval and development contemplated therein shall not impact the current and future lot owners of the following parcels, R08518-001-014- 004, R08518-001-015-000, and R08518-001-015-002, right to use the access easement shown on the concept plan, nor shall the zoning approval and development contemplated therein create any additional financial burden on those lot owners to contribute to the cost of maintenance for the access road. iv. The northern terminus of the access easement shall be designated for public use to allow potential future connection to and through adjoining parcels to Seabreeze Road. 1. To meet condition 4, a public access easement will need to be shown on the end of the road circled in red below. The pavement will also need to be extended to the property boundary. SB Cottages – Major Subdivision – TRC Review Page | 3 v. All stormwater management areas shown on the concept plan shall be required. Changes to the general shape of the basins as required by essential site improvements may be accepted administratively by Planning staff. b. Project proposes a performance residential development consisting of 47 dwelling units in the form of 10 quadraplexes (40 units), two duplexes or dual unit attached dwellings (4 units), and one triplex (3 units). i. The application indicates the site is 7.39 acres with 1.63 acres identified as marshes and 0.07 acres identified as Class IV soils that are not intended for permanent conservation. 1. 7.39 – 1.63 – 0.07 = 5.69 acres that can be used to count towards the density of the project. 2. The maximum density in the R-5 district is 8 dwelling units per acre. 3. 5.69 x 8 = 45.52 dwelling units. Fractional numbers 0.5 and above are rounded up to the nearest whole number = 46 total units allowed for the development. This matches the maximum number approved for the conditional rezoning. 4. The proposed preliminary plan shows 47 dwelling units. 1 dwelling unit must be removed from the project c. Staff recommend including the location of traffic calming devices on the preliminary plans. Installation of traffic calming devices is not required, but including potential locations on the plan ensures the future HOA / owners will have the opportunity to install them without conducting a traffic study. SB Cottages – Major Subdivision – TRC Review Page | 4 d. While the Army Corps of Engineers has not provided comments on this version of the project yet, they may send additional comments that will be forwarded at a later date. 2. UDO Section 5.1, Parking and Loading a. The plan will need to show the location, number, and size of all parking spaces in the development. i. The number of parking spaces for quadraplexes and triplexes is: 1.5 parking spaces per dwelling unit for 1-bedroom units, or 2 parking spaces per dwelling unit for 2-bedroom units. ii. The number of parking spaces for duplexes or dual unit attached dwellings is: 2 parking spaces per dwelling unit. iii. Garages may count towards the number of parking spaces however, the plan must indicate which units will have garages. However, if the plan indicates a garage will be provided and the future building permit application does not include a garage, the permit may be held until either the preliminary plan is updated or the building plans are updated to ensure compliance. 3. UDO Section 5.2, Traffic, Access and Connectivity a. Please note that no building permit for any structure shall be issued which requires NCDOT approval for a Driveway Permit until NCDOT has issued the permit approval. Evidence of approval shall accompany the application for building permit. 4. UDO Section 5.3, Tree Retention a. Note: Land disturbance permits can be issued by county Engineering before a Tree Removal Permit is approved by Planning. However, any trees removed before the Tree Removal Permit is issued may result in enforcement action under Section 5.3.2 of the Unified Development Ordinance to include prohibiting any development of the site for 3 to 5 years. b. The preliminary plan appears to indicate compliance with the condition to preserve existing specimen and significant trees on site identified during the rezoning process. c. Several of the trees appear to be in the road right-of-way. While not prohibited, staff cautions that roadway or utility work in the right-of-way may damage the roots of the tree. d. A separate tree removal permit application is required before any documented trees may be removed from the site. SB Cottages – Major Subdivision – TRC Review Page | 5 5. UDO Section 5.4, Landscaping and Buffering a. Landscaping and buffering are only required for the amenity areas in residential developments. The site does not include an amenity area, therefore the landscaping standards do not apply. 6. UDO Section 5.5, Lighting a. Please note under 5.5.2.A that a lighting plan is not required for single-family residential projects and the county does not require streetlights, however a lighting plan is required for any amenity area. 7. UDO Section 5.6, Signs a. Will the development have an entrance sign for the subdivision? b. If so, the plan needs to include the location of the sign. c. If the sign is along a DOT maintained road or near an intersection with a DOT road (including the driveway access). The sign must be outside the DOT sight triangles. d. For any signs on the site, a separate sign permit must be submitted and reviewed by the county for compliance with Section 5.6 of the UDO for standards at or after the submittal of the separate zoning compliance and construction permits for the primary building or use. 8. UDO Section 5.7, Conservation Resources a. Section 5.7 does not apply to the project. b. The Conservation Resources map indicates portions of the site may have pocosin conservation resources. However, the soil map indicates there are no Class IV soils on site. Pocosin conservation resources must be underlaid by Class IV soils to trigger additional ordinance requirements. 9. UDO Section 5.8, Open Space Requirements a. Project is proposing a performance residential development which requires a minimum 20% open space. b. The draft preliminary plan shows areas for stormwater and land around the proposed homes but does not specifically label or show the areas for open space. c. The plan will need to include the open space acreage in the site notes and label the open space areas on the preliminary plan. SB Cottages – Major Subdivision – TRC Review Page | 6 10. UDO Article 6, Subdivision Design and Improvements. a. Section 6.3.3.J.1.d requires sidewalks on both sides of the street for residential developments in the R-5 district. Preliminary plan does not show sidewalks as part of the plan. i. Prior discussions with the developer has indicated an intention to request an exemption from the sidewalk requirement under Section 6.3.3.J.2 which states “The TRC may exempt sidewalk installation in specific cases upon finding that sidewalks are unnecessary for the protection of the public safety or welfare due to conditions peculiar to the site.” ii. Is it the intention to request an exemption from the sidewalk requirement? And if so, please provide a statement regarding the specific conditions of the site that may warrant the exemption. b. The preliminary plan meets the block length requirement. c. Section 6.2.2.A.6.g Street Connectivity Standards requires a minimum link to node ratio of 1.40. The proposed project has 11 links and 7 nodes for a ratio of 1.57. d. The pavement and right-of-way for the two roads terminating to the north of the site need to be extended to the property line. e. Make sure to specify whether the rights-of-way as public or private. f. The plan shows the majority of the roads with a 40 foot right-of-way width. A portion is as narrow as 33.15 feet. The minimum width for private local roads is 45 feet wide. 11. UDO Article 9, Flood Damage Prevention a. A small portion of the site is in the floodplain. The site plan shows no development is proposed in the floodplain area. A floodplain development permit is not required. However, if any clearing, grading, fill, or other work is proposed in the floodplain, a floodplain development permit is required. b. Please confirm if any work is proposed in the floodplain? NHC Fire Services, David Stone 910-798-77458 Compliance with the NC Fire Code 1. The access road serving units 1-8 is a dead end in excess of 150 feet. This road will require an approved that complies with Appendix D103.4 and Table D103.4. 2. No gates or traffic calming devices unless approved by TRC. SB Cottages – Major Subdivision – TRC Review Page | 7 NHC Engineering, Galen Jamison 910-798-7072 Stormwater management and land disturbance 1. A County stormwater and land disturbing permit issued by the County is required for this project. Please digitally submit the permit applications documentation with requisite review fees to the COAST online permit portal (https://newhanovercountync- energovpub.tylerhost.net/apps/selfservice#/home). Applicable forms can be found at https://www.nhcgov.com/251/Stormwater-Permitting and https://www.nhcgov.com/249/Sediment-Erosion-Controlhowever. 2. Please contact the State for their stormwater permit requirements. It is anticipated a new high density permit will be required. NHC Environmental Health, Dustin Fenske 910-798-6732 Septic tanks and wells 1. Site plan shows connection to a public water supply. Proposed infrastructure maintains setbacks to surrounding properties well heads. Environmental Health records indicate a potential well at 7641 Carolina Beach Rd. Developer shall investigate this potential well and protect the well head during demolition. Well head shall be properly abandoned by a Certified Well Driller. 2. Site plan reflects connection to public sewer. Proposed infrastructure maintains setbacks to surrounding properties septic systems. Environmental Health records reflect a possible septic system at 7641 Carolina Beach Rd. Developer shall be mindful of this possibility and investigate. Abandon the septic system by pump, crush and fill of septic tank. NHC Addressing, McCabe Watson 910-798-7068 Street naming and property address 1. Each of the 5 streets will need to be assigned a name. Please submit street name proposals with alternatives prior to TRC approval. 2. Please contact me for address assignment following TRC approval. SB Cottages – Major Subdivision – TRC Review Page | 8 Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 Public water and sewer 1. CFPUA TRC Comments provided are preliminary comments only. 2. CFPUA water and sewer not available. NCDOT, Nick Drees 910-343-3915 Driveway access and state road improvements 1. See attached. WMPO, Luke Hutson 910-343-3915 New Hanover County contracted traffic engineering services comments: 1. See attached. Project information also provided to the following state agencies and non-regulatory local agencies for their awareness: New Hanover County Emergency Management New Hanover County Sustainability Manager New Hanover County Soil & Water Conservation New Hanover County Schools NC Department of Environmental Quality (DEQ) NC DEQ Division of Coastal Management NC DEQ Division of Energy, Mineral, and Land Resources US Army Corps of Engineers STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION JOSH STEIN DANIEL H. JOHNSON GOVERNOR SECRETARY Mailing Address: NC DEPARTMENT OF TRANSPORTATION DIVISION OF HIGHWAYS 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUIT 101 WILMINGTON, NC 28403 Memorandum DATE: October 13, 2025 TO: New Hanover County Technical Review Committee SUBJECT: SB Cottages – 7641/7645/7647 Carolina Beach Road ________________________________________________________________________ These are preliminary comments and are based on the plans as submitted for the proposed site. They are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. General Comments: NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT Online Portal.https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx You can coordinate with the District Office with any questions 910-398-9100. NCDOT Driveway Permit: An NCDOT Driveway Permit is required. Submit plans in accordance with pages 14 and 15 of the Policy on Street and Driveway Access to North Carolina Highways to include access locations within 500’ of the proposed access on both sides of the State Road. Submit to the local NCDOT District Engineer’s Office. • Refer to the NCDOT checklist (included) for required documents and site plan information. NCDOT Encroachment Agreement: An NCDOT Encroachment Agreement is required for any utility connections or installations within the NCDOT right-of-way (form 16.6). • It is recommended that you reach out to the NCDOT District Office prior to submitting plans to avoid a redesign of the proposed utilities. • Refer to the NCDOT UAM Manual and the NCDOT encroachment checklist for required documents and site plan information. Mailing Address: NC DEPARTMENT OF TRANSPORTATION DISTRICT 3 ENGINEER’S OFFICE 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 An NCDOT Encroachment Agreement is required for any sidewalk or multi-use paths installed within the NCDOT right-of-way (form 16.6). Site Plan Comments: Drainage/Stormwater Conveyance: • If the drainage does not naturally flow to the NCDOT right of way the historic drainage pattern should be maintained. • Additional information is needed on the existing and proposed drainage in the area. Identification Signing and Landscaping: • Identification signing or landscape vegetation within the median and the sight distance triangle must not obstruct the driver’s line of sight. No landscaping or signing will be allowed to exceed 42 inches in height, measured from the Edge of Pavement (EOP) within the median or sight triangle. • All pylon signs in the median or sight distance triangle must provide a vertical clear sight zone between 3 feet-6 inches and 10 feet-0 inches measured from the EOP. Signing located within a clear recovery area shall be of a “breakaway design.” • Only low growing shrubbery, consistent with the NCDOT’s landscaping policies, as contained in the publication “Guidelines for Planting Within Highway Right of Way,” will be allowed within a landscaped median and the sight distance triangle at the entranceway to a development, whether the street or driveway connection to the State Highway System is designated as a public facility or not. Landscaping within the right-of-way and sight distance triangles may require additional approval by the District Engineer. NCDOT | Division 3 | District 3 Project Name:_____________________________ Date:_______________ Applicant Checklist NCDOT Checklist Driveway Application Process and Site Plan Requirements ALL APPLICATIONS SHALL BE ACCOMPANIED BY COMPLETE AND DETAILED SITE PLANS THAT ADHERE TO THE POLICIES LISTED IN THE POLICY ON STREET AND DRIVEWAY ACCESS TO NORTH CAROLINA HIGHWAYS AND THIS DOCUMENT. FAILURE TO ADHERE TO THESE POLICIES WILL RESULT IN THE RETURN OF THE APPLICATION TO THE APPLICANT FOR REVISION. ***THE NCDOT WILL NOT BEGIN THE REVIEW PROCESS ON INCOMPLETE APPLICATIONS*** Electronic Pre-Submittals In an effort to save time and resources, we are happy to provide an initial assessment of a driveway permit submittal’s plans via email to identify any major issues up front. This initial assessment can be followed up with a submittal of one digital copy of the plans along with all other required documents. All Permit applications shall be submitted through the online portal https://connect.ncdot.gov/site/Permits/Pages/default.aspx In the notify email section of the portal application please include the District Office email (Div3Dist3@ncdot.gov). See the last pages for further instruction. Online resources: •NCDOT Policy on Street and Driveway Access to North Carolina Highways: https://connect.ncdot.gov/projects/Roadway/RoadwayDesignAdministrativeDocuments/Policy%20on%20Street%20an d%20Driveway%20Access.pdf •NCDOT Policies and Procedures for Accommodating Utilities on Highway Rights of Way: https://connect.ncdot.gov/municipalities/Utilities/Pages/UtilitiesManuals.aspx •Electronic Forms Database: https://connect.ncdot.gov/Pages/default.aspx 1) a.Cover Letter Include contact information for applicant and engineer, including email address, mailing address, and phone number. Include the parcel number(s), description of all phases of the development and future land uses to be served by the permit, and a description of the adjoining land owned or controlled by the applicant. b.NCDOT Street and Driveway Access Permit Application (form downloadable via link below) https://connect.ncdot.gov/resources/BusinessForms/TEB-65-04.doc c.$50.00 Inspection Fee Per Access Point Attach to Permit Application form (not applicable for municipalities, churches, and schools) d.NPDES Stormwater Permit Compliance Certification (form downloadable via link below) https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/NPDESstatement.doc e.Verification of Compliance with Environmental Regulations (form downloadable via link below) https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/VCER-1.pdf f.Site Plans (to include the “Master Plan” of a tract even if only a small portion is being developed first) Additional site plan requirement details can be found in section 2 of this document. g.Design Plan Requirements for projects involving roadway improvements If roadway improvements are required as part of the permit, then roadway plans, pavement marking plans,signing plans, and traffic control plans will be required - See Section 6 for more information Y N n/a Engineering Studies The applicant may be required by the District Engineer to submit studies based on, but not limited to, the parameters outlined herein. If study requirements of the local government agency are more restrictive than the NCDOT requirements, then local government requirements will govern. However, this does not imply that the NCDOT is obligated to approve entrance designs that are too constrictive to allow smooth and safe traffic flow. All studies including, but not limited to, Traffic Impact Analyses (TIA), traffic signal studies, and drainage studies, must be prepared under the direct charge of and sealed by a North Carolina licensed Professional Engineer. Section 1: Requi red Documents |Required documents to accompany all Initial Driveway Application Submittals Please note that these are the minimum requirements of all driveway permit applications. All required documentation shall be submitted through the online portal as PDF files, with the exception of the Performance and Indemnity Bond and the $50 Inspection Fee(s), these should be mailed or delivered to 5501 Barbados Blvd, Castle Hayne, NC 28429. If a Traffic Impact Analysis and/or roadway improvements are deemed necessary as a condition of the permit, there may be additional submittal materials required. State of North Carolina | Department of Transportation | Division 3 | District 3 5501 Barbados Blvd, Castle Hayne, NC 28429 Form Updated 10/15/2021 (910) 398-9100 T NCDOT Permit #___________________ Y N n/a Section 1: Required Documents (continued) 2)Required documents to accompany all Driveway Applications PRIOR TO FINAL APPROVAL a.Site Plans One (1) digital copy (PDF) unless otherwise requested by the District Office. Additional site plan requirement details can be found in section 2 of this document. b.Performance and Indemnity Bond Information/Forms See last page of document for bond information and forms c.Performance and Indemnity Bond Amount 100% of the cost of the work within NCDOT Right-of-Way (R/W) based on the attached estimate determined by the applicant's engineer and approved by the District Engineer. Bond hold letter required for for municipalities, churches, and schools. See pages 101-105 in the Policies and Procedures for Accommodating Utilities on Highway Rights of Way for acceptable bond types d.Radius Encroachment Letter (if applicable) If driveway radius encroaches on the frontage of an adjacent property, a Radius Encroachment will be required e.Hold Harmless Letter (if applicable) If the Permit is within the limits of an active NCDOT project, a Hold Harmless letter from the NCDOT contractor will be required. If the project is in preconstruction, coordinate with the Department's Project Development Unit Section 2: General Site Plan Requirements | All site plans shall include and show, at a minimum, the items listed below Page numbers reference the NCDOT Policy on Street and Driveway Access to North Carolina Highways 1)Drawn to a scale of 20, 30, 40, or 50 feet per inch and the scale shall be shown 2)North arrow, vicinity map, date of plan, and date of most-recent revision if applicable 3)Contact information of applicant and engineer, including mailing address, phone number, and email address 4)Show R/W lines, highway control of access, and property lines 5)All existing utilities (including handholes) and easements 6)R/W width 7)Existing posted speed limit(s) and design speed limit(s) 8)Show all property lines, intersections, signals, signal loops, railroads, or crossovers within 500’ in all directions of the property lines of the proposed development 9)Show location of sidewalks, crosswalks, greenways, multi-use paths, curb ramps, railroads, bus stops, and any other relevant transportation facilities in the development area 10)Include a plan sheet showing full site build-out and land use 11)Buildings shown with “gross leasable area” 12)Width of property frontage 13)Distance from R/W to buildings and gasoline service islands 14)Distance from R/W to existing/proposed Edge of Pavement (EOP) (pages 32 & 34) 15)All streams, bridges, retaining walls, signs, or other fixed objects such as trees, utility poles, traffic signals, etc. Section 3: Driveway Plan Requirements | All driveway plans shall include and show, at a minimum, the items listed below 1)Provide comprehensive survey within the existing R/W on both sides of the road for a distance of 500’ in all directions from the development’s property lines. Provide additional hydraulic survey data to the nearest storm water inlet/outlet including ditch lines and storm water pipes, if located outside of the 500' distance. 2)Lane configurations and widths of all existing and proposed driveways, roadways, and adjacent roadways 3)All driveway widths (2-way: 20’ minimum, 36’ maximum | 1-way: 12’ minimum, 24’ maximum | with island: 14'ingress, 18' egress) (pages 50 & 77) 4)Driveway Profile - In shoulder sections, maintain minimum 2% fall from edge of travel way for required shoulder width distance Primary: 8’ minimum | Secondary: 6’ minimum 5)All existing and/or proposed driveway radii (20’ minimum, 50’ maximum, 30’ typical) (pages 34 & 51) In curb and gutter sections, use City of Wilmington flare (SD 3-03.3) - (see attached) In shoulder sections, show grades at the EOP and centerline 6)No curbing is allowed within NCDOT R/W along shoulder sections except as part of a driveway island (page 31) 7)Driveway angles of approach to existing roadway (90° preferred, 75°-90° required for 2-way driveways, 45°-90° allowed for right-in/right-out on a case-by-case basis) (page 51) 8)Driveway Profile (pages 42- 43) Y N n/a Y N n/a □□ □□ □ □ Y N n/a Y N n/a Y N n/a Y N n/a Section 3: Driveway Plan Requirements (continued) 9)Driveway Pavement Cross Section (to be in place from EOP to edge of R/W) Asphalt: 8” ABC stone and 1.5” S9.5B Concrete: 6” of concrete 10)Driveway Offset (driveway EOP to property line; page 75): Minimum: 20’ 11)Corner Clearance (radius point to radius point; page 52)Minimum: 50’ Desirable: 100’ or Municipal std. 12)Minimum 10’x70’ sight triangles at driveways (measured from and along the R/W line) (page 31) 13)Sight Distance (length of sight-distance in both directions shown for each driveway; pages 27-29) 14)Driveways should be aligned with existing opposing driveways or correct offset should be provided (pages 40-41) 15)Distance between driveways being requested (if applicable; page 51) 16)Minimum internal storage areas with specified queues (pages 31-33) 17)Minimum protected driveway stem(s) provided and indicated (pages 33-34) 18)Indicate any gated entrances (100’ minimum setback from R/W required) - traffic queuing study may be required | Section 6: Roadway Plan Requirements If off-site improvements are required, roadway plans shall show, at a minimum, the items below 1)Full width typical sections must be shown (paved shoulders to match the typical section of the adjacent roadway) 2)Minimum Asphalt Typical Section (for turn lanes and/or paved shoulders) Adjacent recently-completed or upcoming TIP projects w/ different typical sections may supersede those below •Primary Routes (US & NC) and Secondary Routes with Annual Average Daily Traffic (AADT) ≥10,000 5.5” B25.0C, 3” I19.0C, 1.5” S9.5C; any overlay of existing pavement is to be a minimum of 1.5” S9.5C •Secondary Routes with AADT<10,000 5.5” B25.0C, 1.5” S9.5B; any overlay of existing pavement is to be a minimum of 1.5” S9.5B 3)Pavement overlay is required if modification of existing pavement markings and/or lanes is necessary The grinding of pavement markings will not be allowed 4)Shoulder Widths (Paved + Unpaved) Primary: 8’ minimum | Secondary: 6’ minimum 5)Ditch Slopes - front and back slopes - minimum 3:1 or flatter 6)Indicate existing roadway grade 7)All taper lengths and deceleration lengths should be appropriately designed for the given design speed (page 78) 8)All turn lanes should be designed according to the Driveway Manual and Roadway Standard Drawings (page 79) See 1205.04 Sheets 1 & 2 and 1205.05 Sheet 1 of the Roadway Standard Drawings for details 9)Pavement marking and signing plans are required - plans must be approved by Division Traffic Services 10)Traffic control plans are required - Detailed phasing plans may be required based on project type and location 11)New and/or revised signal plans must be included for new installations and if signal modifications are required All signal plans must be reviewed and approved by Division Traffic Services and the Signal Design Unit. A Traffic Agreement must be completed to facilitate the review. Contact Division Traffic Services at (910) 341-2200. | Section 4: Drainag e Requirements All drainage features on NCDOT Right-of-Way shall adhere to, at a minimum, the items listed below Section 5: Internal Circ ulation Requirements |All internal circulation details shall adhere to, at a minimum, the items listed below 1)Interior driveway channelization stems Minimum 100’ from the ROW or at the discretion of the District Engineer 2)Traffic flow pattern 3)Traffic control devices 4)Pavement Markings Y N n/a Y N n /a Y N n/a Y N n/a Y N n/a Y N n/a Y N n/a Y N n/a 1)Pipe Cover Minimums (measured from top of pipe to subgrade) High Density Polyethylene (HDPE): 24” | Corrugated Aluminum (CAP): 12” | Reinforced Concrete (RCP): 12” 2)Pipe End Treatment (see Roadway Design Manual 5-20, B-2) Pipes ≤24" on multilane highways posted above 45mph require Parallel Pipe End Sections See 310.02 and 310.04 of the Roadway Standard Drawings for details Pipes >30" on multilane highways posted above 45mph require guardrail Pipes ≥36" require an endwall on the inlet end 3)All proposed Drainage is to be provided inside existing R/W. Otherwise, additional R/W or a permanently dedicated drainage easement will be required to accommodate the proposed project drainage 4)All sizes, types, and invert elevations of existing/proposed pipes and drainage structures must be shown(see Sec.3 #1 for survey requirements) 5)Provide spot elevations along frontage of driveway (at EOP and centerline) 6)Provide grades and spot elevations for existing and proposed ditches 7)Show how drainage will be accommodated along property frontage(District Engineer may require applicant to provide drainage calculations when warranted) C/L EOTEOP P/L R/WR/W R/W EOP EOP EOP EOP NTS R/W P/L DRAINAGE FLOW DRAINAGE FLOW DRAINAGE FLOW SHOULDER WIDTH SHOULDER WIDTH SHOULDER WIDTH SHOULDER WIDTH S IGHT T R IANG LE 10 ' BY 70 'S I GHT T R I ANGL E10' B Y 70' DRIVEWAY RR MIN. 30'MIN. 30' NO ROADWAY IMPROVEMENT COMMERCIAL DRIVEWAY WITH NORMAL CROWN ROADWAY 6" LOWER THAN THE EDGE OF PAVEMENTMIN 2% FALL AWAY or 20' AWAY FROM THE PROPERTY LINEDRIVEWAY SHALL BE LOCATED AT LEAST PIPE/TYPE/SIZE WIDTH CON CR ET E /ASP HA LT LOCAL NAME ROAD POSTED SPEED ( ) MPH WIDTH WIDTHSR NUMBER SITE ADDRESS:TAX PARCEL # 20191115 PARALLEL END S.D. 310.02 INVERT ELEVATION PARALLEL END S.D. 310.02 INVERT ELEVATION 20' AWAY FROM THE PROPERTY LINEDRIVEWAY SHALL BE LOCATED AT LEAST OR 500' OF XYZ SURVEY DATA PAST THE PROPERT LINENEAREST OUTFALL ELEVATION OR 500' OF XYZ SURVEY DATA PAST THE PROPERT LINENEAREST OUTFALL ELEVATION MEMORANDUM To: New Hanover County Technical Review Committee Date: October 9, 2025 Subject: Pandion Drive Subdivision NCDOT Projects: • N/A WMPO 2045 MTP Projects: • N/A New Hanover County Projects: • NHC_BikePedPriorities_2024 – Carolina Beach Road South. From Monkey Junction to Snow Cut Bridge. 10’ paved MUP is being installed in close proximity to this site location. TIA: Based on the 11th edition ITE Trip Generation Manual, a TIA is not required Land Use (ITE Code) Intensity Unit 24 Hour Volumes AM Peak Hour Trips PM Peak Hour Trips Single Family Detached Housing (210) 47 Dwelling Units 308 19 24 Insea Marine – 3419 Castle Hayne Road – TRC Review Page | 1 To: Stephen Conway, Insea Land Acquisitions, LLC From: Katherine May, Development Review Planner Date: November 5, 2025 Technical Review Committee (TRC) PID#: R02511-004-017-000 Egov# SITECN-25-000101 Subject: 3419 Castle Hayne Road– Insea Marine - TRC Review Technical Review Committee (TRC) General Information The TRC is a staff-level group of local government officials that reviews projects for compliance with the local regulations administered by each respective review agency. Voluntarily participating state agencies may also provide comments. And general information and non-binding recommendations about the site may also be provided by government agencies. The TRC meetings are considered staff meetings and are not public hearings. The TRC meeting is an opportunity for applicants to speak with county staff and any voluntarily participating state or federal agencies about the review comments they have been provided. No voting is involved in the TRC process, and no final approvals or denials are made at the TRC meetings. Following the TRC meeting, applicants are responsible for updating their plans to address review comments. Those revised plans need to be resubmitted to the assigned case planner. The case planner will facilitate additional reviews until all comments have been addressed, and the necessary departments have stated the plans comply with the applicable minimum requirements for development. Following any future TRC approval, the project is required to obtain additional permits to include a zoning compliance permit for the site. Applicants are also responsible for coordinating with state and federal agencies for compliance with any additional requirements. Any activity on the property that is not approved as part of the TRC review and zoning compliance permit will be considered a violation of the UDO and subject to enforcement action under Article 12 Violations and Enforcement. The following comments have been received for the November 5th, 2025, TRC meeting. Additional comments may be made upon further review of subsequent revisions. Insea Marine – 3419 Castle Hayne Road – TRC Review Page | 2 Planning, Katherine May 910-798-7443 Compliance with local UDO requirements 1. General Comments a. Zoning district is CZD B-2 b. This project is associated with rezoning case Z25-12 and was approved with the following conditions. Please add these conditions to the site plan. i. The setbacks as shown on the concept plan must remain. ii. A 6-foot-high screening fence shall be required along the northern boundary of the gravel service yard as shown on the concept plan. iii. No development or outdoor storage shall occur within the existing utility easement as shown on the concept plan. The easement shall constitute an additional spatial buffer and the required transitional buffer shall be installed along the northern portion of the easement if the easement-holder does not permit landscaping inside the easement. iv. The permitted uses are limited to Contactor Office for the main building and Warehousing for the two accessory buildings. c. As stated in the application the intended use is Contractor Office and Warehousing. The Unified Development Ordinance (UDO) defines the uses as i. Contractor Office: An establishment primarily engaged in the day-to-day administrative and clerical services for businesses providing contracted services, such as building contractors, heating and air conditioning (HVAC) repair, landscaping and janitorial services, etc., that require outside and/or fleet storage. The use may include some on-site repair and material preparation work. ii. Warehousing: The storing of goods, wares, and merchandise within an enclosed building, whether for the owners or others. There is little on-site sales activity with the customer present. Uses include: cold storage facilities (including frozen food lockers); distribution warehouses (used primarily for temporary storage pending distribution in response to customer orders); storage warehouses (used for storage by retail stores such as furniture and appliance stores); warehouse storerooms; or similar uses. Insea Marine – 3419 Castle Hayne Road – TRC Review Page | 3 d. The Planning and Land Use Department’s review of the site is for compliance with the UDO and use specific requirements of the specified land use. Any other activity that might occur on the property beyond the definition above should be noted on the application and site plan for additional review and comment. e. Plans note a Duke easement on this property. Please confirm with Duke Energy to get Duke Energy approval for this site plan before proceeding with any other permits. 2. UDO Section 5.1, Parking and Loading a. The calculation for parking is provided on the site plan. However, since the main building will be split between contractor office and workshop space, please show the square footage for each use and show which areas will be used for each use. 3. UDO Section 5.2, Traffic, Access and Connectivity a. Please note that no building permit for any structure shall be issued which requires NCDOT approval for a Driveway Permit until NCDOT has issued the permit approval. Evidence of approval shall accompany the application for building permit. b. The WMPO’s estimated AM and PM traffic generation is provided on the site plan. Thank you. 4. UDO Section 5.3, Tree Retention a. Tree retention standards are included on the plan. A tree removal permit has been submitted, thank you. I will be in touch with next steps. b. For the required mitigation of the removed significant trees, are you planning to replace the lost inches, pay the fee, or a combination of both? c. Note: Land disturbance permits can be issued by county Engineering before a Tree Removal Permit is approved by Planning. However, any trees removed before the Tree Removal Permit is issued may result in enforcement action under Section 5.3.2 of the Unified Development Ordinance to include prohibiting any development of the site for 3 to 5 years. 5. UDO Section 5.4, Landscaping and Buffering a. Just a reminder that replacement inches for removed significant trees cannot be used in required landscaping. b. Per the conditions of this rezoning, a 6-foot-high screening fence shall be required along the northern boundary of the gravel service yard as shown on the concept plan approved by the Board of Commissioners – This is reflected on the plan. Insea Marine – 3419 Castle Hayne Road – TRC Review Page | 4 c. While the grass maintenance was included on C-2, please submit the full landscaping plan as soon as possible which includes the following information: Street yard, parking lot landscaping, foundation plantings, buffer plantings, replacement trees, etc. 6. UDO Section 5.5, Lighting a. Please note that a lighting plan is not required for TRC approval but will be required prior to issuance of construction plan approvals. b. Is any lighting proposed for the site? 7. UDO Section 5.6, Signs a. The plan states no signs are proposed at this time. b. If a future sign is proposed for the site, a separate sign permit must be submitted and reviewed by the county for compliance with Section 5.6 of the UDO for standards at or after the submittal of the separate zoning compliance and construction permits for the primary building or use. Any approvals granted by the TRC for the site design is not an approval for the ultimate size or placement of the sign. 8. UDO Section 5.7, Conservation Resources a. The conservation resources map does not indicate any conservation resources impacting the property, this section does not apply. 9. UDO Article 9, Flood Damage Prevention a. No areas of the property are in a floodplain. NHC Fire Services, Ray Griswold 910-798-7448 Compliance with NC Fire Code 1. Fire extinguishers per NFPA 2. Fire finals required NHC Engineering, Galen Jamison 910-798-7072 Stormwater management and land disturbance 1. Please submit for permit revisions to County stormwater permit STMW-20-0043 and land disturbance permit LNDP-20-00133. Please digitally submit the permit applications documentation with requisite review fees to the COAST online permit portal (https://newhanovercountync-energovpub.tylerhost.net/apps/selfservice#/home) using the referenced permit numbers Insea Marine – 3419 Castle Hayne Road – TRC Review Page | 5 2. All conveyance calculations will need to be updated per the latest NHC stormwater design manual. 3. Please contact the State for their stormwater permit requirements. NHC Environmental Health, Dustin Fenske 910-798-6732 Septic tanks and wells 1. Site plan reflects connection to public water and sewer. Records reflect the site is surrounded by parcels that are connected to public water and sewer. No septic or well issues are apparent for this site design. NHC Addressing, McCabe Watson 910-798-7068 Street naming and property address 1. Each proposed building will need its own individual address. 2. Please contact me for address assignment following TRC approval. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 Public water and sewer 1. CFPUA TRC Comments provided are preliminary comments only. 2. CFPUA is moving toward becoming paperless. When ready to submit plan review package, upload all documents to https://www.cfpua.org/FormCenter/Engineering-3/Engineering- Plan-Review-103. 3. CFPUA water and sewer available. •Capacity is dependent on the analysis of the pipe collection system (gravity and force mains) 4. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE Application Form and a Preliminary Plan, this determination does not guarantee capacity. 5. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the Authority. Insea Marine – 3419 Castle Hayne Road – TRC Review Page | 6 NCDOT, Nick Drees 910-343-3915 Driveway access and state road improvements 1. Please see attachment. WMPO, Caitlin Cerza 910-473-5130 New Hanover County contracted traffic engineering services comments: 1. Please see attachment. Army Corps of Engineers, Brad Shaver 910-251-4611 Information or Requirements if wetlands are impacted 1. No comments. Project information also provided to the following state agencies and non-regulatory local agencies for their awareness: New Hanover County Emergency Management New Hanover County Schools NC Department of Environmental Quality (DEQ) NC DEQ Division of Coastal Management NC DEQ Division of Energy, Mineral, and Land Resources New Hanover County Sustainability Manager NHC Soil & Water Conservation MEMORANDUM To: New Hanover County Technical Review Committee Date: October 9, 2025 Subject: InSea Marine NCDOT Projects: • I-6037: I-140 – US 421 to I-40 Rehabilitate Bridge and pavement. Is in close proximity to this site. WMPO 2045 MTP Projects: • I-6037 – Is also in the 2045 MTP. New Hanover County Projects: • N/A TIA: Based on the 11th edition ITE Trip Generation Manual, a TIA is not required Land Use (ITE Code) Intensity Unit 24 Hour Volumes AM Peak Hour Trips PM Peak Hour Trips Warehouse (150) 23,925 SF 76 27 29 General Office (710) 1,500 SF 30 5 5 STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION JOSH STEIN DANIEL H. JOHNSON GOVERNOR SECRETARY Mailing Address: NC DEPARTMENT OF TRANSPORTATION DIVISION OF HIGHWAYS 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUIT 101 WILMINGTON, NC 28403 Memorandum DATE: October 13, 2025 TO: New Hanover County Technical Review Committee SUBJECT: InSea Marine – 3419 Castle Hayne Road ________________________________________________________________________ These are preliminary comments and are based on the plans as submitted for the proposed site. They are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. General Comments: NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT Online Portal.https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx You can coordinate with the District Office with any questions 910-398-9100. NCDOT Driveway Permit: An NCDOT Driveway permit has been submitted to NCDOT for review (on 10/10/25). •Permit Number D033-065-25-00158. NCDOT Encroachment Agreement: An NCDOT Encroachment Agreement is required for any utility connections or installations within the NCDOT right-of-way (form 16.6). •Refer to the NCDOT UAM Manual and the NCDOT encroachment checklist for required documents and site plan information. An NCDOT Encroachment Agreement is required for any sidewalk or multi-use paths installed within the NCDOT right-of-way (form 16.6). Mailing Address: NC DEPARTMENT OF TRANSPORTATION DISTRICT 3 ENGINEER’S OFFICE 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Roadway Improvements: The plan submitted to New Hanover County shows a right turn lane (extension) into the site while the plans submitted to NCDOT show a standard driveway connection within the merge taper. • One of the plans sets should be revised/removed. Site Plan Comments: Drainage/Stormwater Conveyance: • If the drainage does not naturally flow to the NCDOT right of way the historic drainage pattern should be maintained. NCDOT Standard Drawings: • Include/update the NCDOT Standard Drawings (2024) that are applicable to the development. Sight Triangles and Sight Distance: • Show and label the 10’ X 70’ NCDOT sight triangles. o No obstructions shall be placed within the NCDOT sight triangles. • Show and label the stopping sight distance. o No obstructions shall be placed within the stopping sight distance. Identification Signing and Landscaping: • Identification signing or landscape vegetation within the median and the sight distance triangle must not obstruct the driver’s line of sight. No landscaping or signing will be allowed to exceed 42 inches in height, measured from the Edge of Pavement (EOP) within the median or sight triangle. • All pylon signs in the median or sight distance triangle must provide a vertical clear sight zone between 3 feet-6 inches and 10 feet-0 inches measured from the EOP. Signing located within a clear recovery area shall be of a “breakaway design.” • Only low growing shrubbery, consistent with the NCDOT’s landscaping policies, as contained in the publication “Guidelines for Planting Within Highway Right of Way,” will be allowed within a landscaped median and the sight distance triangle at the entranceway to a development, whether the street or driveway connection to the State Highway System is designated as a public facility or not. Landscaping within the right-of-way and sight distance triangles may require additional approval by the District Engineer. Mailing Address: NC DEPARTMENT OF TRANSPORTATION DISTRICT 3 ENGINEER’S OFFICE 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Gated Entrances: • Show and label any proposed gates with distances to the right of way line. Driveway Radius: • Make sure to accommodate the largest proposed vehicle. Internal Stem Protection: • Label the internal protection stem length for the proposed driveway connection. o Measured from the right-of-way line. Future NCDOT STIP: This development is located within a future STIP. With that in mind, any access that conflicts with the planned transportation infrastructure may be modified and/or removed and there shall not be any compensation made by NCDOT. The current STIP is proposed as a divided facility. Therefore, the permitted access point/point will be restricted as right-in/right-out only in the future. (Pu b l i c R / W ) Ch a i r R o a d Gla d i o l u s R d (6 0 ' P u b l i c R / W ) 35 36 33 34 35 32 31 Inv=32.3 EX.DITop=34.4Inv=32.2 33 31 32 32 33 32 32 32 32 32 32 31 33 34 3333 32 3332 32 33 31 3232 32 33 3231 31 15" RCP 2X8"MAP 8"GUM10"GUM 12"GUM 10"GUM 14"PINE 2X8"GUM 8"MAP 8"GUM2X10"GUM 20"OAK 8"OAK 2X8"OAK 10"OAK 12"OAK10"CHY 10"OAK 14"PINE 12"PINE 10"GUM 12"PINE 8"GUM 8"OAK12"OAK 10"OAK 8"GUM 10"GUM12"OAK 8"GUM 8"GUM 14"PINE 14"PINE 14"PINE 14"PINE 8"GUM 8"MAP 16"GUM 12"MAP 8"MAP 12"MAP 3X4"MAG 10"MAP 10"MAP 8"MAP 2X4"CHY 14"PINE 16"PINE 8"MAP 8"MAP 12"PINE 10"GUM 12"PINE 8"GUM 14"GUM 16"PINE 12"PINE 8"MAP 10"GUM14"GUM 12"PINE 8"MAP 3X8"GUM 10"GUM 12"OAK 8"MAP 8"GUM 12"PINE 14"PINE 12"PINE 12"PINE12"PINE 12"PINE 12"PINE 12"PINE 12"PINE 12"PINE 8"GUM 12"PINE 8"GUM 8"OAK 2X8"MAP 12"GUM 2X8"GUM 3X12"GUM 2X10"OAK 2X8"MAP 10"MAP 10"MAP12"MAP 2X16 " L O A K 14"PINE 8"OAK 12"PINE 18"PINE 8"GUM8"GUM 8"GUM 8"MAP 8"GUM 8"MAP 8"GUM 10"GUM 14"PINE 12"PINE 12"PINE 10"GUM8"MAP8"+10"MAP 10"CHY 10"MAP 24"OAK 18"PINE 12"PINE 18"PINE 12"PINE 2X10"GUM 8"MAP8"MAP 22"PINE12"GUM 18"PINE 18"PINE 20"PINE 8"MAP 12"PINE 8"MAP 8"MAP 18"PINE 16"PINE 16"PINE 10"GUM 18"PINE 8"MAP 8"MAP 8"GUM 8"GUM 8"MAP8"MAP 10"GUM 10"GUM12"GUM 8"MAP 8"MAP8"MAP 8"OAK 8"MAP8"MAP10"MAP 10"GUM 2X8"GUM 16"PINE 22"OAK 10"OAK 10"OAK 10"MAP 12"PINE 16"PINE 8"GUM10"OAK 14"PINE 18"PINE 28"LOAK 2X8"OAK8"OAK 10"OAK 8"GUM 10"OAK36"OAK_CLSTR 16"PINE 8"GUM 14"PINE 14"PINE 14"PINE 12"PINE 8"OAK 12"PINE 10"GUM 8"GUM 8"OAK 8"+10"OAK 8"GUM 8"OAK 12"PINE 8"OAK 8"OAK 20"PINE 14"PINE PROPOSED POND PROPOSED GRAVELPARKING SEP T I C A R E A 12"PINE APPROX. LOCATION EX. 16" WATER MAIN N/FCastle HayneDevelopment Group, LLCDB 6680 Pg 2687ZONING: (CZD) B-2USE: RETAIL EXISTING F.H. EXISTING F.H. EX. ON-SITE DRAINAGESWALES TO BE FILLED 32 C-0 1 EX I S T I N G C O N D I T I O N S , T R E E RE M O V A L / P R O T E C T I O N A N D DE M O L I T I O N P L A N 1" = 30' PROPERTY LINEADJOINERSEASEMENTTREE PROTECTION FENCELIMITS OF DISTURBANCE REGULATED TREES TO BE REMOVED SIGNIFICANT TREES TO BE REMOVED LEGEND REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): 2025-013 CLIENT INFORMATION: InSEA Land Acquisitions, L.L.C.6252 Towles RoadWilmington, NC 28409 OF 4 JAE CDC CDC 24x36 9/26/2025 In S e a M a r i n e O f f i c e PREL I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N I-140 Chair Rd Cas t l e H a y n e R d Rockhill Rd Oakley R d Swartville Rd Gladiolus RdSITE SITE DATA PARCEL ID: R02511-004-017-000 CURRENT ZONING: (CZ)B-2 PROJECT ADDRESS: 3419 CASTLE HAYNE RD.CASTLE HAYNE, NC 28429 CURRENT OWNER: INSEA LAND ACQUISITIONS LLC6252 TOWLES RD. WILMINGTON, NC 28409 TOTAL ACREAGE IN PROJECT BOUNDARY 187,499 S.F. (± 4.3 ac.) EXISTING ONSITE IMPERVIOUS AREAS (SITE IS VACANT): SOILS TYPE: Mu (Murville fine sand - Group A)Pn (Pantego loam - Group A)(Per NHC GIS Soil Map) NOTES:1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY LANDDEVELOPMENT CODE.2. PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTYREGULATIONS.3. EXISTING SURVEYING PERFORMED BY TALBOT LAND SURVEYING, P.C.4. SITE IS LOCATED IN ZONE "X" PER FRIS ON FIRM MAP NUMBER 3720322000, DATED8/28/2018.5. NO WETLANDS, SURFACE WATERS, PROTECTED VEGETATED SETBACKS OR RIPARIANBUFFERS EXIST ON SITE PER DAVEY RESOURCE GROUP, INC.6. PRIOR TO CLEARING, GRADING, OR CONSTRUCTION ACTIVITY, ANY WELLS THAT AREEXISTING MUST BE PROTECTED AROUND EACH WELL HEAD/CASING AND CAPPED.7. ALL PINE TREES ARE ASSUMED TO BE LOBLOLLY PINES. ALL GUM TREES AREASSUMED TO BE SWEET GUMS. OWNER MUST VERIFY SPECIES PRIOR TO CLEARINGAND NOTIFY ENGINEER AND NEW HANOVER COUNTY OF ANY RELEVANT CHANGES. TREE PRESERVATION NOTES:1. PRIOR TO ANY CLEARING, GRADING, OR CONSTRUCTION ACTIVITY, APPROVED TREEPROTECTION FENCING, SUCH AS SAFETY BARRIER FENCING, A WOODEN SLAT SNOWFENCE OR WIRE FENCE, SHALL BE INSTALLED AROUND PROTECTED TREES OR TREESTANDS LOCATED IN CONSTRUCTION AREAS OR OTHER SITE AREAS THAT WILL BEDISTURBED BY CONSTRUCTION ACTIVITIES. THE FENCING SHALL BE A MINIMUM OFFOUR FEET IN HEIGHT AND BE OF DURABLE CONSTRUCTION. TREE PROTECTIVEFENCING SHALL REMAIN IN PLACE THROUGH COMPLETION OF CONSTRUCTIONACTIVITIES.2. NO CONSTRUCTION WORKERS, TOOLS, MATERIALS, OR VEHICLES ARE PERMITTEDWITHIN THE TREE PROTECTION FENCING.3. IF AN EXISTING TREE RETAINED TO COMPLY WITH THE STANDARDS OF THIS SECTIONIS DESTROYED, SUBSTANTIALLY DAMAGED, OR DIES AS A RESULT OF NEGLIGENCE ONTHE PART OF THE PROPERTY OWNER WITHIN THREE YEARS AFTER COMPLETION OFCONSTRUCTION, THEN REPLACEMENT TREES SHALL BE PLANTED ON THE SITE WITHA TOTAL DIAMETER EQUAL TO TWICE THE DIAMETER OF THE RETAINED TREE. AMINIMUM GROWING AREA OF 144 SQUARE FEET SHALL BE PROVIDED FOR EACHREPLACEMENT TREE. IF THE PLANNING DIRECTOR DETERMINES IT IS INFEASIBLE ORFOR REPLACEMENT TREE(S) TO BE ACCOMMODATED ON THE SITE, THEN A PAYMENTMAY BE MADE TO THE COUNTY’S TREE IMPROVEMENT FUND EQUIVALENT TO THEPRICING STANDARDS IN THE COUNTY FEE SCHEDULE. MITIGATION REQUIRED FOR REMOVAL OFSIGNIFICANT TREES QTY SIZE TYPE REPLACEMENTINCHES136"OAK CLUSTER 72.00 1 24"OAK 48.00 122" OAK44.00 TOTAL REPLACEMENT INCHES 164 60'30'15'30'0' Scale: 1"=30' (Pu b l i c R / W ) Ch a i r R o a d PROP. CONTRACTOROFFICE/WORKSHOPBUILDING14,625 SFFFE: 34.5 GRAVEL 18 ' 9' 5' SIDEWALK APP R O X . L O C A T I O N P R O P O S E D SEP T I C A R E A (DE S I G N / P E R M I T T I N G B Y O T H E R S ) Gl a d i o l u s R d (6 0 ' P u b l i c R / W ) 20' Rear Setback & Bufferyard 20' S e t b a c k & B u f f e r y a r d 6' Hi g h S c r e e n i n g F e n c e 25' Front Setback & Streetyard PR O P . W A R E H O U S E BU I L D I N G 3,6 0 0 S F FF E : 3 4 . 5 ASPHALT 36' R35'R3 5 ' 90 ' 20' 62' 26' 30' 35 36 33 34 35 32 31 Inv=32.3 EX.DITop=34.4Inv=32.2 33 31 32 32 33 32 32 32 32 32 32 31 33 34 3333 32 3332 32 33 31 3232 32 33 3231 31 15" RCP 20"OAK 8"OAK10"OAK 12"OAK10"CHY 10"OAK10"GUM 8"GUM 8"OAK12"OAK 10"OAK 12"OAK 2X10"OAK 8"GUM8"GUM 8"GUM 8"MAP 18"PINE 28"LOAK 12"PINE 8"OAK 8"+10"OAK 8"GUM 12"PINE 8"OAK 8"OAK 20"PINE 14"PINE APPROX. LOCATION EX. 16" WATER MAIN 24" FESINV: 30.510'X15'X18" ED SDMH#3RIM: 33.5INV: 30.9 DI#3RIM: 33.5INV: 29.5 DI#4RIM: 33.4INV: 30.5 MATCH EX. ASPHALT±34.9 34.55 15 " R C P 33.9 34.0 34.0 34.0 34.4 34.034.4 34.4 34.4 34.4 34.434.4 34.25 30' 34.0 34.4 34.0 34.4 34.034.4 18" PPES #2INV: 31.255'X10'X12" ED 18" PPES #1INV: 31.4 3' CURB OPENING 3' CURBOPENING DI#5RIM: 33.4INV: 30.8 PROPOSED WETDETENTION BASINTOB: 33.5FP: 32.3NP: 31.0BTM: 24.0 26 . 5 34.0 33.9 N/FCastle HayneDevelopment Group, LLCDB 6680 Pg 2687ZONING: (CZD) B-2USE: RETAIL EXISTING F.H. EXISTING F.H. 33 32 33 33 33 32 33 32 34.0 34.4 8'8' 34.25 TAPER CURB TO FLAT 32 34.7 34.55 32 SDMH#1RIM: 34.0INV: 30.45 1,285 sf 855 sf DI#2RIM: 33.5INV: 30.1 90' C-1 1 SI T E , G R A D I N G , D R A I N A G E , ST O R M W A T E R , & U T I L I T I E S P L A N 1" = 30' SITE DATA PARCEL ID: R02511-004-017-000 CURRENT ZONING: (CZ)B-2 PROJECT ADDRESS: 3419 CASTLE HAYNE RDCASTLE HAYNE NC 28429 CURRENT OWNER: INSEA LAND ACQUISITIONS LLC6252 TOWLES RD. WILMINGTON, NC 28409 TOTAL ACREAGE IN PROJECT BOUNDARY 187,499 S.F. (± 4.3 ac.) PROPOSED USE: CONTRACTORS OFFICE AND STORAGE BUILDING SIZE: 25,425 S.F. TOTAL (3 BUILDINGS) BUILDING HEIGHT: 1-STORY/±25' CALCULATION FOR BUILDING COVERAGE:PROPOSED COVERAGE 25,425 S.F. ÷ 187,499 S.F. = 13.56% BUILDING SETBACKS: FRONT: REQUIRED= 25' PROPOSED= 88'SIDE: REQUIRED= 20' PROPOSED= 131'L/65'RREAR: REQUIRED= 20' PROPOSED= 21' PROPOSED IMPERVIOUS AREAS:BUILDINGS 25,425 S.F.ASPHALT PARKING AREA 7,090 S.F.GRAVEL AREA 44,945 S.F.CONCRETE SIDEWALK 650 S.F.TOTAL 78,110 S.F (41.66%) PARKING REQUIRED:CONTRACTOR OFFICE USE: (3/1,000 sf)1,500 SF/1,000*3 = 5 SPACES WAREHOUSE USE *over 20,000 sf: (1/1,000 sf)23,925 SF/1,000*1 = 24 SPACES PARKING PROVIDED: *6 SPACES (1 ADA)*Warehouse parking provided in the gravel service yards* PARKING LOT INTERIOR LANDSCAPINGREQUIRED 7,090 S.F. * 8% 567 S.F.PROVIDED 2,140 S.F. FOUNDATION PLANTINGS: CONTRACTOR OFFICE BLDG: 65 LF X 15' FACADE X 12%REQUIRED:117 S.F.PROVIDED:135 S.F. WAREHOUSE BUILDINGS:REQUIRED: N/A (BUILDINGS BEHIND GATED FENCE AND NOT VISIBLE FROM R/W) STREETYARD: (25 S.F./LF FRONTAGE. 12.5' MIN./37.5' MAX. WIDTHS)207 LF FRONTAGE 243- 36 LF DRIVEWAYS =207 LF FRONTAGEREQUIRED: 25' X 207 LF 5,175 S.F.PROVIDED:5,175 S.F. EXISTING SEWER AND WATER DEMAND: 0 GPD PROPOSED SEWER AND WATER DEMAND: 250 GPD ESTIMATED TRIP GENERATION (Per Trip Generation Manual 11th Edition):23,925 SF WAREHOUSE (ITE CODE 150)AM PEAK: 4 PM PEAK: 4 DAILY: 41 1,500 SF OFFICE (ITE CODE 710)AM PEAK: 2 PM PEAK: 2 DAILY: 16 PROJECT TOTAL: AM PEAK: 6 PM PEAK: 6 DAILY: 57 REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): 2025-013 CLIENT INFORMATION: InSEA Land Acquisitions, L.L.C.6252 Towles RoadWilmington, NC 28409 OF 4 JAE CDC CDC 24x36 9/26/2025 In S e a M a r i n e O f f i c e PREL I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N I-140 Chair Rd Cas t l e H a y n e R d Rockhill Rd Oakley R d Swartville Rd Gladiolus RdSITE PROPERTY LINERIGHT OF WAYADJOINERSEXISTING EDGE OF PAVEMENTEASEMENT EXISTING FIRE HYDRANT RUNOFF DIRECTION PROPOSED SPOT ELEVATION PARKING LOT INT. LANDSCAPING FOUNDATION PLANTINGS LEGEND DEVELOPMENT NOTES:1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY LAND DEVELOPMENT CODE.2. PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS.3. NO SIGNS ARE PROPOSED AT THIS TIME. ANY FUTURE PROPOSED SIGN IS SUBJECT TO SECTION 5.6. OF THE UDO.3. RUNOFF FROM ALL IMPERVIOUS SURFACES, INCLUDING ROOF DRAINS, TO BE DIRECTED TO WET DETENTION BASIN. 60'30'15'30'0' Scale: 1"=30' UTILITY NOTES:1. WATER SERVICE TO BE PROVIDED BY PROPOSED ON-SITE WELL. DESIGN, LOCATION AND PERMITTING BY OTHERS.2. SANITARY SEWER SERVICE TO BE PROVIDED VIA ONSITE PRIVATE SEPTIC SYSTEM.3. ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS & TELEPHONE SHALL BE INSTALLED UNDERGROUND.4. THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIES DURING CONSTRUCTION.CALL NC811 AT 811 OR 1-800-632-4949. CONTRACTOR IS RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ANY UTILITIES,CURB & GUTTER, PAVEMENT, ETC. THAT MAY BE BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIREDTO AT LEAST THE QUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM.5. SOLID WASTE DISPOSAL IS BY PRIVATE DUMPSTER SERVICE. FIRE & SAFETY NOTES:1. CONSTRUCTION TYPE: II-B (COMMERCIAL)2. BUILDINGS WILL NOT BE SPRINKLED.3. CONTRACTOR SHALL MAINTAIN AN ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES DURING CONSTRUCTION.4. BUILDING INFORMATION SIGNS MUST BE PROVIDED IN ACCORDANCE WITH THE "2018 NC FIRE CODE APPENDIX J"REQUIREMENTS.5. CONTRACTOR SHALL SUBMIT A RADIO SIGNAL STRENGTH STUDY FOR ALL COMMERCIAL BUILDINGS THAT DEMONSTRATES THATEXISTING EMERGENCY RESPONDER RADIO SIGNAL LEVELS MEET THE REQUIREMENTS OF SECTION 510 OF THE 2018 NC FIRECODE.6. ANY DRIVEWAY GATE TO BE SIREN ACTIVATED AND HAVE KNOX KEY OVERRIDE.7. ALL FIRE HYDRANTS MUST BE INSTALLED WITH 5 INCH STORZ QUICK CONNECTS ON A 4.5 INCH STEAMER IN COMPLIANCE WITHNHC FIRE SERVICE REQUIREMENTS.8. NO OBSTRUCTIONS WITHIN 36" AROUND A FIRE HYDRANT, INCLUDING BUT NOT LIMITED TO, STREET SIGNS, LANDSCAPING ANDUTILITY POLES AND BOXES.9. NEW HYDRANTS MUST BE BROUGHT INTO SERVICE PRIOR TO COMBUSTIBLE MATERIALS DELIVERED TO THE JOB SITE.10. ANY GATES WILL REQUIRE PROPER PERMITTING THROUGH A KNOX ENTRY SYSTEM FOR EMERGENCY ACCESS. 34.55 NCDOT | Division 3 | District 3 Project Name:_____________________________ Date:_______________ Applicant Checklist NCDOT Checklist Driveway Application Process and Site Plan Requirements ALL APPLICATIONS SHALL BE ACCOMPANIED BY COMPLETE AND DETAILED SITE PLANS THAT ADHERE TO THE POLICIES LISTED IN THE POLICY ON STREET AND DRIVEWAY ACCESS TO NORTH CAROLINA HIGHWAYS AND THIS DOCUMENT. FAILURE TO ADHERE TO THESE POLICIES WILL RESULT IN THE RETURN OF THE APPLICATION TO THE APPLICANT FOR REVISION. ***THE NCDOT WILL NOT BEGIN THE REVIEW PROCESS ON INCOMPLETE APPLICATIONS*** Electronic Pre-Submittals In an effort to save time and resources, we are happy to provide an initial assessment of a driveway permit submittal’s plans via email to identify any major issues up front. This initial assessment can be followed up with a submittal of one digital copy of the plans along with all other required documents. All Permit applications shall be submitted through the online portal https://connect.ncdot.gov/site/Permits/Pages/default.aspx In the notify email section of the portal application please include the District Office email (Div3Dist3@ncdot.gov). See the last pages for further instruction. Online resources: •NCDOT Policy on Street and Driveway Access to North Carolina Highways: https://connect.ncdot.gov/projects/Roadway/RoadwayDesignAdministrativeDocuments/Policy%20on%20Street%20an d%20Driveway%20Access.pdf •NCDOT Policies and Procedures for Accommodating Utilities on Highway Rights of Way: https://connect.ncdot.gov/municipalities/Utilities/Pages/UtilitiesManuals.aspx •Electronic Forms Database: https://connect.ncdot.gov/Pages/default.aspx 1) a.Cover Letter Include contact information for applicant and engineer, including email address, mailing address, and phone number. Include the parcel number(s), description of all phases of the development and future land uses to be served by the permit, and a description of the adjoining land owned or controlled by the applicant. b.NCDOT Street and Driveway Access Permit Application (form downloadable via link below) https://connect.ncdot.gov/resources/BusinessForms/TEB-65-04.doc c.$50.00 Inspection Fee Per Access Point Attach to Permit Application form (not applicable for municipalities, churches, and schools) d.NPDES Stormwater Permit Compliance Certification (form downloadable via link below) https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/NPDESstatement.doc e.Verification of Compliance with Environmental Regulations (form downloadable via link below) https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/VCER-1.pdf f.Site Plans (to include the “Master Plan” of a tract even if only a small portion is being developed first) Additional site plan requirement details can be found in section 2 of this document. g.Design Plan Requirements for projects involving roadway improvements If roadway improvements are required as part of the permit, then roadway plans, pavement marking plans,signing plans, and traffic control plans will be required - See Section 6 for more information Y N n/a Engineering Studies The applicant may be required by the District Engineer to submit studies based on, but not limited to, the parameters outlined herein. If study requirements of the local government agency are more restrictive than the NCDOT requirements, then local government requirements will govern. However, this does not imply that the NCDOT is obligated to approve entrance designs that are too constrictive to allow smooth and safe traffic flow. All studies including, but not limited to, Traffic Impact Analyses (TIA), traffic signal studies, and drainage studies, must be prepared under the direct charge of and sealed by a North Carolina licensed Professional Engineer. Section 1: Requi red Documents |Required documents to accompany all Initial Driveway Application Submittals Please note that these are the minimum requirements of all driveway permit applications. All required documentation shall be submitted through the online portal as PDF files, with the exception of the Performance and Indemnity Bond and the $50 Inspection Fee(s), these should be mailed or delivered to 5501 Barbados Blvd, Castle Hayne, NC 28429. If a Traffic Impact Analysis and/or roadway improvements are deemed necessary as a condition of the permit, there may be additional submittal materials required. State of North Carolina | Department of Transportation | Division 3 | District 3 5501 Barbados Blvd, Castle Hayne, NC 28429 Form Updated 10/15/2021 (910) 398-9100 T NCDOT Permit #___________________ Y N n/a Section 1: Required Documents (continued) 2)Required documents to accompany all Driveway Applications PRIOR TO FINAL APPROVAL a.Site Plans One (1) digital copy (PDF) unless otherwise requested by the District Office. Additional site plan requirement details can be found in section 2 of this document. b.Performance and Indemnity Bond Information/Forms See last page of document for bond information and forms c.Performance and Indemnity Bond Amount 100% of the cost of the work within NCDOT Right-of-Way (R/W) based on the attached estimate determined by the applicant's engineer and approved by the District Engineer. Bond hold letter required for for municipalities, churches, and schools. See pages 101-105 in the Policies and Procedures for Accommodating Utilities on Highway Rights of Way for acceptable bond types d.Radius Encroachment Letter (if applicable) If driveway radius encroaches on the frontage of an adjacent property, a Radius Encroachment will be required e.Hold Harmless Letter (if applicable) If the Permit is within the limits of an active NCDOT project, a Hold Harmless letter from the NCDOT contractor will be required. If the project is in preconstruction, coordinate with the Department's Project Development Unit Section 2: General Site Plan Requirements | All site plans shall include and show, at a minimum, the items listed below Page numbers reference the NCDOT Policy on Street and Driveway Access to North Carolina Highways 1)Drawn to a scale of 20, 30, 40, or 50 feet per inch and the scale shall be shown 2)North arrow, vicinity map, date of plan, and date of most-recent revision if applicable 3)Contact information of applicant and engineer, including mailing address, phone number, and email address 4)Show R/W lines, highway control of access, and property lines 5)All existing utilities (including handholes) and easements 6)R/W width 7)Existing posted speed limit(s) and design speed limit(s) 8)Show all property lines, intersections, signals, signal loops, railroads, or crossovers within 500’ in all directions of the property lines of the proposed development 9)Show location of sidewalks, crosswalks, greenways, multi-use paths, curb ramps, railroads, bus stops, and any other relevant transportation facilities in the development area 10)Include a plan sheet showing full site build-out and land use 11)Buildings shown with “gross leasable area” 12)Width of property frontage 13)Distance from R/W to buildings and gasoline service islands 14)Distance from R/W to existing/proposed Edge of Pavement (EOP) (pages 32 & 34) 15)All streams, bridges, retaining walls, signs, or other fixed objects such as trees, utility poles, traffic signals, etc. Section 3: Driveway Plan Requirements | All driveway plans shall include and show, at a minimum, the items listed below 1)Provide comprehensive survey within the existing R/W on both sides of the road for a distance of 500’ in all directions from the development’s property lines. Provide additional hydraulic survey data to the nearest storm water inlet/outlet including ditch lines and storm water pipes, if located outside of the 500' distance. 2)Lane configurations and widths of all existing and proposed driveways, roadways, and adjacent roadways 3)All driveway widths (2-way: 20’ minimum, 36’ maximum | 1-way: 12’ minimum, 24’ maximum | with island: 14'ingress, 18' egress) (pages 50 & 77) 4)Driveway Profile - In shoulder sections, maintain minimum 2% fall from edge of travel way for required shoulder width distance Primary: 8’ minimum | Secondary: 6’ minimum 5)All existing and/or proposed driveway radii (20’ minimum, 50’ maximum, 30’ typical) (pages 34 & 51) In curb and gutter sections, use City of Wilmington flare (SD 3-03.3) - (see attached) In shoulder sections, show grades at the EOP and centerline 6)No curbing is allowed within NCDOT R/W along shoulder sections except as part of a driveway island (page 31) 7)Driveway angles of approach to existing roadway (90° preferred, 75°-90° required for 2-way driveways, 45°-90° allowed for right-in/right-out on a case-by-case basis) (page 51) 8)Driveway Profile (pages 42- 43) Y N n/a Y N n/a □□ □□ □ □ Y N n/a Y N n/a Y N n/a Y N n/a Section 3: Driveway Plan Requirements (continued) 9)Driveway Pavement Cross Section (to be in place from EOP to edge of R/W) Asphalt: 8” ABC stone and 1.5” S9.5B Concrete: 6” of concrete 10)Driveway Offset (driveway EOP to property line; page 75): Minimum: 20’ 11)Corner Clearance (radius point to radius point; page 52)Minimum: 50’ Desirable: 100’ or Municipal std. 12)Minimum 10’x70’ sight triangles at driveways (measured from and along the R/W line) (page 31) 13)Sight Distance (length of sight-distance in both directions shown for each driveway; pages 27-29) 14)Driveways should be aligned with existing opposing driveways or correct offset should be provided (pages 40-41) 15)Distance between driveways being requested (if applicable; page 51) 16)Minimum internal storage areas with specified queues (pages 31-33) 17)Minimum protected driveway stem(s) provided and indicated (pages 33-34) 18)Indicate any gated entrances (100’ minimum setback from R/W required) - traffic queuing study may be required | Section 6: Roadway Plan Requirements If off-site improvements are required, roadway plans shall show, at a minimum, the items below 1)Full width typical sections must be shown (paved shoulders to match the typical section of the adjacent roadway) 2)Minimum Asphalt Typical Section (for turn lanes and/or paved shoulders) Adjacent recently-completed or upcoming TIP projects w/ different typical sections may supersede those below •Primary Routes (US & NC) and Secondary Routes with Annual Average Daily Traffic (AADT) ≥10,000 5.5” B25.0C, 3” I19.0C, 1.5” S9.5C; any overlay of existing pavement is to be a minimum of 1.5” S9.5C •Secondary Routes with AADT<10,000 5.5” B25.0C, 1.5” S9.5B; any overlay of existing pavement is to be a minimum of 1.5” S9.5B 3)Pavement overlay is required if modification of existing pavement markings and/or lanes is necessary The grinding of pavement markings will not be allowed 4)Shoulder Widths (Paved + Unpaved) Primary: 8’ minimum | Secondary: 6’ minimum 5)Ditch Slopes - front and back slopes - minimum 3:1 or flatter 6)Indicate existing roadway grade 7)All taper lengths and deceleration lengths should be appropriately designed for the given design speed (page 78) 8)All turn lanes should be designed according to the Driveway Manual and Roadway Standard Drawings (page 79) See 1205.04 Sheets 1 & 2 and 1205.05 Sheet 1 of the Roadway Standard Drawings for details 9)Pavement marking and signing plans are required - plans must be approved by Division Traffic Services 10)Traffic control plans are required - Detailed phasing plans may be required based on project type and location 11)New and/or revised signal plans must be included for new installations and if signal modifications are required All signal plans must be reviewed and approved by Division Traffic Services and the Signal Design Unit. A Traffic Agreement must be completed to facilitate the review. Contact Division Traffic Services at (910) 341-2200. | Section 4: Drainag e Requirements All drainage features on NCDOT Right-of-Way shall adhere to, at a minimum, the items listed below Section 5: Internal Circ ulation Requirements |All internal circulation details shall adhere to, at a minimum, the items listed below 1)Interior driveway channelization stems Minimum 100’ from the ROW or at the discretion of the District Engineer 2)Traffic flow pattern 3)Traffic control devices 4)Pavement Markings Y N n/a Y N n /a Y N n/a Y N n/a Y N n/a Y N n/a Y N n/a Y N n/a 1)Pipe Cover Minimums (measured from top of pipe to subgrade) High Density Polyethylene (HDPE): 24” | Corrugated Aluminum (CAP): 12” | Reinforced Concrete (RCP): 12” 2)Pipe End Treatment (see Roadway Design Manual 5-20, B-2) Pipes ≤24" on multilane highways posted above 45mph require Parallel Pipe End Sections See 310.02 and 310.04 of the Roadway Standard Drawings for details Pipes >30" on multilane highways posted above 45mph require guardrail Pipes ≥36" require an endwall on the inlet end 3)All proposed Drainage is to be provided inside existing R/W. Otherwise, additional R/W or a permanently dedicated drainage easement will be required to accommodate the proposed project drainage 4)All sizes, types, and invert elevations of existing/proposed pipes and drainage structures must be shown(see Sec.3 #1 for survey requirements) 5)Provide spot elevations along frontage of driveway (at EOP and centerline) 6)Provide grades and spot elevations for existing and proposed ditches 7)Show how drainage will be accommodated along property frontage(District Engineer may require applicant to provide drainage calculations when warranted) C/L EOTEOP P/L R/WR/W R/W EOP EOP EOP EOP NTS R/W P/L DRAINAGE FLOW DRAINAGE FLOW DRAINAGE FLOW SHOULDER WIDTH SHOULDER WIDTH SHOULDER WIDTH SHOULDER WIDTH S IGHT T R IANG LE 10 ' BY 70 'S I GHT T R I ANGL E10' B Y 70' DRIVEWAY RR MIN. 30'MIN. 30' NO ROADWAY IMPROVEMENT COMMERCIAL DRIVEWAY WITH NORMAL CROWN ROADWAY 6" LOWER THAN THE EDGE OF PAVEMENTMIN 2% FALL AWAY or 20' AWAY FROM THE PROPERTY LINEDRIVEWAY SHALL BE LOCATED AT LEAST PIPE/TYPE/SIZE WIDTH CON CR ET E /ASP HA LT LOCAL NAME ROAD POSTED SPEED ( ) MPH WIDTH WIDTHSR NUMBER SITE ADDRESS:TAX PARCEL # 20191115 PARALLEL END S.D. 310.02 INVERT ELEVATION PARALLEL END S.D. 310.02 INVERT ELEVATION 20' AWAY FROM THE PROPERTY LINEDRIVEWAY SHALL BE LOCATED AT LEAST OR 500' OF XYZ SURVEY DATA PAST THE PROPERT LINENEAREST OUTFALL ELEVATION OR 500' OF XYZ SURVEY DATA PAST THE PROPERT LINENEAREST OUTFALL ELEVATION 3305 Fredrickson Road– Commercial Flex Space – TRC Review Page | 1 To: Natalie Oakes, DAE Building, Inc From: Katherine May, Development Review Planner Date: November 5, 2025 Technical Review Committee (TRC) PID#: R03200-002-035-000 Egov# SITECN-24-000102 Subject: 3305 Fredrickson Road– Commercial Flex Space - TRC Review Technical Review Committee (TRC) General Information The TRC is a staff-level group of local government officials that reviews projects for compliance with the local regulations administered by each respective review agency. Voluntarily participating state agencies may also provide comments. And general information and non-binding recommendations about the site may also be provided by government agencies. The TRC meetings are considered staff meetings and are not public hearings. The TRC meeting is an opportunity for applicants to speak with county staff and any voluntarily participating state or federal agencies about the review comments they have been provided. No voting is involved in the TRC process, and no final approvals or denials are made at the TRC meetings. Following the TRC meeting, applicants are responsible for updating their plans to address review comments. Those revised plans need to be resubmitted to the assigned case planner. The case planner will facilitate additional reviews until all comments have been addressed, and the necessary departments have stated the plans comply with the applicable minimum requirements for development. Following any future TRC approval, the project is required to obtain additional permits to include a zoning compliance permit for the site. Applicants are also responsible for coordinating with state and federal agencies for compliance with any additional requirements. Any activity on the property that is not approved as part of the TRC review and zoning compliance permit will be considered a violation of the UDO and subject to enforcement action under Article 12 Violations and Enforcement. The following comments have been received for the November 5, 2025, TRC meeting. Additional comments may be made upon further review of subsequent revisions. 3305 Fredrickson Road– Commercial Flex Space – TRC Review Page | 2 Planning, Katherine May 910-798-7443 Compliance with local UDO requirements 1. General Comments a. Zoning district – I-2 b. This project is not associated with a rezoning. c. As stated in the application the intended use is commercial flex space. The applicant confirmed that the intended UDO defined use to be Offices for Private Business and Professional Activities. The Unified Development Ordinance (UDO) defines the use as i. Establishments primarily engaged in the day-to-day administrative or clerical services for businesses or other organizations that provide professional or other services to the general public on a walk-in or appointment basis in an office setting. d. The Planning and Land Use Department’s review of the site is for compliance with the UDO and use specific requirements of the specified land use. Any other activity that might occur on the property beyond the definition above should be noted on the application and site plan for additional review and comment. e. There does not appear to be any Duke Energy Transmission Lines/Easement on the Property. f. Under site data, it states one building consisting of 9,600 sq ft. There appears to be two separate buildings. Please show the total square footage of each building. 2. UDO Section 5.1, Parking and Loading a. The use of Offices for Private Business and Professional Activities requires 2.5 parking spaces for every 1,000 square feet of building area. Project proposes 9,600 square feet. Required parking is 9,600 / 1,000 = 9.6 x 2.5 = 24 required parking spaces. However, the plan is reflecting only 13 spaces. b. Per UDO Section 5.1.3.A you may submit a parking demand study to reduce the amount of spaces. 3. UDO Section 5.2, Traffic, Access and Connectivity a. Please note that no building permit for any structure shall be issued which requires NCDOT approval for a Driveway Permit until NCDOT has issued the permit approval. Evidence of approval shall accompany the application for building permit. b. Please add the WMPO’s estimated AM and PM traffic generation on the site plan. 3305 Fredrickson Road– Commercial Flex Space – TRC Review Page | 3 4. UDO Section 5.3, Tree Retention a. The site is currently cleared and the plan states there will be no tree removal. b. Note: Land disturbance permits can be issued by county Engineering before a Tree Removal Permit is approved by Planning. However, any trees removed before the Tree Removal Permit is issued may result in enforcement action under Section 5.3.2 of the Unified Development Ordinance to include prohibiting any development of the site for 3 to 5 years. 5. UDO Section 5.4, Landscaping and Buffering a. A minimum of 15 trees of at least two inches DBH or two caliper inches, as applicable, shall be retained or planted on a parcel where development occurs for each acre or proportionate area disturbed by the development. 15 trees x 0.79 acre = 11.85 (12) trees. The plan exceeds this requirement. b. A landscaped buffer is not required between I-2 zoned properties. c. The dumpster is adequately screened. d. Parking lot landscaping was not included in the landscape data – please add this. See Table 5.4.5.C: Standards for Parking Lot Interiors. Please note that the parking lot interior landscaping is 8% of the total area used for parking, 6. UDO Section 5.5, Lighting a. Please note that a lighting plan is not required for TRC approval but will be required prior to issuance of construction plan approvals. b. Is any lighting proposed for the site? 7. UDO Section 5.6, Signs a. Are any free-standing signs proposed for the property? If so, please indicate the location. b. For any signs on the site, a separate sign permit must be submitted and reviewed by the county for compliance with Section 5.6 of the UDO for standards at or after the submittal of the separate zoning compliance and construction permits for the primary building or use. Any approvals granted by the TRC for the site design is not an approval for the ultimate size or placement of the sign. 8. UDO Section 5.7, Conservation Resources a. The conservation resources map does not indicate any conservation resources impacting the property, this section does not apply. 3305 Fredrickson Road– Commercial Flex Space – TRC Review Page | 4 9. UDO Article 9, Flood Damage Prevention a. The property is not in the floodplain. NHC Fire Services, Ray Griswold 910-798-7448 Compliance with NC Fire Code 1. Fire finals required 2. Portable fire extinguishers per NFPA 10 NHC Engineering, Galen Jamison 910-798-7072 Stormwater management and land disturbance 1. A County stormwater and land disturbing permit issued by the County is required for this project. Please digitally submit the permit applications documentation with requisite review fees to the COAST online permit portal (https://newhanovercountync- energovpub.tylerhost.net/apps/selfservice#/home). Applicable forms can be found at https://www.nhcgov.com/251/Stormwater-Permitting and https://www.nhcgov.com/249/Sediment-Erosion-Controlhowever. 2. Please contact the State for their stormwater permit requirements. It is anticipated a new high density permit will be required. NHC Environmental Health, Dustin Fenske 910-798-6732 Septic tanks and wells 1. Site plan reflects connection to public water. Proposed infrastructure does not violate setbacks to surrounding properties wells. 2. Application states a private septic system for this site. Design wastewater flow is very specific to what type of business occupies a space. This flow determines how large a septic system is needed. With many unknowns, it is suggested that the applicant consults with a Licensed Soil Scientist to discuss wastewater flow, business needs and available soil areas for subsurface disposal. Permitting can be done by local Environmental Health or a Private Soil Scientist. Septic permits must be issued prior to any building permit being issued. NHC Addressing, McCabe Watson 910-798-7068 Street naming and property address 3305 Fredrickson Road– Commercial Flex Space – TRC Review Page | 5 1. Each building and suite will need its own individual address. 2. Please contact me for address assignment following TRC approval. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 Public water and sewer 1. CFPUA TRC Comments provided are preliminary comments only. 2. CFPUA is moving toward becoming paperless. When ready to submit plan review package, upload all documents to https://www.cfpua.org/FormCenter/Engineering-3/Engineering- Plan-Review-103. 3. CFPUA water available; CFPUA sewer is not available. 4. CFPUA Meter Sizing Form will be required. NCDOT, Nick Drees 910-343-3915 Driveway access and state road improvements 1. Please see attached comments. WMPO, Caitlin Cerza 910-473-5130 New Hanover County contracted traffic engineering services comments: 1. Please see attached comments. Army Corps of Engineers, Brad Shaver 910-251-4611 Information or Requirements if wetlands are impacted 1. No comments. Project information also provided to the following state agencies and non-regulatory local agencies for their awareness: New Hanover County Emergency Management New Hanover County Schools NC Department of Environmental Quality (DEQ) 3305 Fredrickson Road– Commercial Flex Space – TRC Review Page | 6 NC DEQ Division of Coastal Management NC DEQ Division of Energy, Mineral, and Land Resources New Hanover County Sustainability Manager NHC Soil & Water Conservation MEMORANDUM To: New Hanover County Technical Review Committee Date: October 9, 2025 Subject: 3008 N Kerr Avenue Flex Space Comments: • Please provide the appropriate Land Use (ITE Code) for the proposed building to ensure accurate trip generation estimates and determine whether a Traffic Impact Analysis (TIA) is required. NCDOT Projects: • N/A WMPO 2045 MTP Projects: • N/A New Hanover County Projects: • N/A TIA: Based on the 11th edition ITE Trip Generation Manual, a TIA is not required. Please confirm that the proper LUC has been used below. Land Use (ITE Code) Intensity Unit 24 Hour Volumes AM Peak Hour Trips PM Peak Hour Trips (822) 9600 Square Feet 523 23 63 STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION JOSH STEIN DANIEL H. JOHNSON GOVERNOR SECRETARY Mailing Address: NC DEPARTMENT OF TRANSPORTATION DIVISION OF HIGHWAYS 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUIT 101 WILMINGTON, NC 28403 Memorandum DATE: October 13, 2025 TO: New Hanover County Technical Review Committee SUBJECT: Covington Flex – 3305 Fredrickson Road ________________________________________________________________________ These are preliminary comments and are based on the plans as submitted for the proposed site. They are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. General Comments: NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT Online Portal.https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx You can coordinate with the District Office with any questions 910-398-9100. NCDOT Driveway Permit: An NCDOT Driveway Permit is required. Submit plans in accordance with pages 14 and 15 of the Policy on Street and Driveway Access to North Carolina Highways to include access locations within 500’ of the proposed access on both sides of the State Road. Submit to the local NCDOT District Engineer’s Office. • Refer to the NCDOT checklist (included) for required documents and site plan information. NCDOT Encroachment Agreement: An NCDOT Encroachment Agreement is required for any utility connections or installations within the NCDOT right-of-way (form 16.6). • Refer to the NCDOT UAM Manual and the NCDOT encroachment checklist for required documents and site plan information. An NCDOT Encroachment Agreement is required for any sidewalk or multi-use paths installed within the NCDOT right-of-way (form 16.6). Mailing Address: NC DEPARTMENT OF TRANSPORTATION DISTRICT 3 ENGINEER’S OFFICE 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Site Plan Comments: Control of Access Fencing: • The control of access fencing for I-140 must remain in place and cannot be removed. • There may be potential to upgrade the current woven wire fence to a decorative fence (approved design) through an encroachment agreement submitted by the property owner. Drainage/Stormwater Conveyance: • If the drainage does not naturally flow to the NCDOT right of way the historic drainage pattern should be maintained. • Additional information is needed on the existing and proposed drainage in the area. • Hydraulic calculations and associated plan sheets will need to be submitted for the site including the proposed 15” RCP crossing Fredrickson Road. o This will be reviewed by the NCDOT Hydraulics Unit. • Prior to moving forward with the site, I would recommend having the storm drainage reviewed/preliminarily approved due to the proposed design. Sight Triangles and Sight Distance: • Show and label the 10’ X 70’ NCDOT sight triangles. o No obstructions shall be placed within the NCDOT sight triangles. • Show and label the stopping sight distance. o No obstructions shall be placed within the stopping sight distance. Identification Signing and Landscaping: • Identification signing or landscape vegetation within the median and the sight distance triangle must not obstruct the driver’s line of sight. No landscaping or signing will be allowed to exceed 42 inches in height, measured from the Edge of Pavement (EOP) within the median or sight triangle. • All pylon signs in the median or sight distance triangle must provide a vertical clear sight zone between 3 feet-6 inches and 10 feet-0 inches measured from the EOP. Signing located within a clear recovery area shall be of a “breakaway design.” Mailing Address: NC DEPARTMENT OF TRANSPORTATION DISTRICT 3 ENGINEER’S OFFICE 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 • Only low growing shrubbery, consistent with the NCDOT’s landscaping policies, as contained in the publication “Guidelines for Planting Within Highway Right of Way,” will be allowed within a landscaped median and the sight distance triangle at the entranceway to a development, whether the street or driveway connection to the State Highway System is designated as a public facility or not. Landscaping within the right-of-way and sight distance triangles may require additional approval by the District Engineer. Gated Entrances: • Show and label any proposed gates with distances to the right of way line. COVINGTON FLEX 3305 FREDRICKSON RD WILMINGTON, NC 28401 DESIGN DEVELOPMENT SEPTEMBER 29, 2025 SHEET INDEX PROJECT NAME: COVINGTON FLEX APPLICANT: DAE BUILDING, INC.717 S. KERR AVENUEWILMINGTON, NC 28403 CONTACT: NATALIE OAKESPHONE: (910) 833-2147, EXT. 111EMAIL: NATALIE@DAEBUILDING.COM PROJECT ADDRESS: 3305 FREDRICKSON RD WILMINGTON, NC 28401 ENGINEER: RIVERVIEW ENGINEERING, PLLC (P-1944)4904 PARK AVENUEWILMINGTON, NC 28403CONTACT: NICHOLAS J. LAURETTA, PE, LEED AP (035107) PHONE: (910) 398-2882EMAIL: NLAURETTA@RIVERVIEWENG.COM SURVEYOR: McKIM & CREED243 N. FRONT STREET WILMINGTON, NC 28401CONTACT: CODY HURSTPHONE: 910-343-1048EMAIL: CHURST@MCKIMCREED.COM PROJECT INFORMATION ENGINEER PROJECT OWNER STAMP CHECKED BY PRINCIPAL IN CHARGE REVISIONS ISSUE FOR ISSUE DATE PROJECT ADDRESS PROJECT NUMBER SHEET TITLE SHEET NUMBER www.rivervieweng.com 4904 PARK AVENUEWILMINGTON, NC 28403(910) 398-2882 nlauretta@rivervieweng.com DRAWN BY CO V I N G T O N F L E X COVER SHEET C-001 DESIGN DEVELOPMENT 1026.02 3305 FREDRICKSON RD WILMINGTON, NC 28401 REVIEW - NOT FOR CONSTRUCTION SEPTEMBER 29, 2025 N. LAURETTA, PE, LEED AP NJL DA E B U I L D I N G , I N C . 711 K E R R A V E N U E WI L M I N G T O N , N C 2 8 4 0 3 NJL/JAT VICINITY MAP1SCALE: 1" = 250' PROJECTVICINITY LOCATION MAP VICINITY MAP PROJECTLOCATION LOCATION MAP2SCALE: 1" = 2000' NUMBER SHEET C-001 COVER SHEET C-002 GENERAL NOTES CX101 EXISTING CONDITIONS PLAN CX102 TREE REMOVAL AND DEMOLITION PLAN CE101 SEDIMENT & EROSION CONTROL PLAN - PHASE 1 CS101 SITE PLAN CS102 DRIVEWAY GRADING PLAN L101 LANDSCAPE PLAN CG101 STORM DRAINAGE AND GRADING PLAN CG103 DRAINAGE AREA MAP CU101 UTILITY PLAN CE501 SEDIMENT & EROSION CONTROL DETAILS CE502 SEDIMENT & EROSION CONTROL DETAILS CS501 SITE DETAILS CU501 UTILITY DETAILS CU502 UTILITY DETAILS CU503 UTILITY DETAILS CG501 UTILITY DETAILS 9/29/25 OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHEOHE OHEEOHE OHE OH OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE                                                                                                                                                                    SD SD SD SD SD SD SD SD SD SD SD SD SD SD   2700414.430RBF 1/2"0.6' A.G.BENT, S.A.B.   2723314.41GAS MKR 2723414.35  GWGW GW GW GW 2717516.04LP GW GW T T PROPERTY LINES PERDEED BOOK AND PAGE PAVEMENT LOCATED WHEREVISIBLE, CONTINUES UNDERGROUND (TO BE REMOVED) 4' HOGWIRE FENCE WITH 1 STRANDBARBED WIRE ON TOP (TO BE REMOVED) INT E R S T A T E I 4 0 N/FCAROLINA POWER & LIGHT COPIN R03200-004-002-000DEED BOOK 507 PAGE 66LUC: 491-UTILITIESZONING: I-2 18" RCPINV=12.32' 18" RCPINV=12.52' 15" RCPINV=12.54' 15" RCPINV=12.56' 15" RCPINV=13.03' 15" RCPINV=13.11'  W W W W W W W W W W W W W W W W W W W W W ELECTRIC PEDESTAL(TO BE REMOVED) LOD LO D LO D LO D LOD LOD LOD LO D LOD LOD LOD LO D LO D LOD LOD LO D LO D LOD LOD LOD LOD LOD LO D LO D LO D LO D LO D LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LO D LO D LO D LO D LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LO D LO D ENGINEER PROJECT OWNER STAMP CHECKED BY PRINCIPAL IN CHARGE REVISIONS ISSUE FOR ISSUE DATE PROJECT ADDRESS PROJECT NUMBER SHEET TITLE SHEET NUMBER www.rivervieweng.com 4904 PARK AVENUEWILMINGTON, NC 28403(910) 398-2882 nlauretta@rivervieweng.com DRAWN BY CO V I N G T O N F L E X DEMOLITION PLAN CX102 DESIGN DEVELOPMENT 1026.02 3305 FREDRICKSON RD WILMINGTON, NC 28401 REVIEW - NOT FOR CONSTRUCTION SEPTEMBER 29, 2025 N. LAURETTA, PE, LEED AP NJL DA E B U I L D I N G , I N C . 711 K E R R A V E N U E WI L M I N G T O N , N C 2 8 4 0 3 NJL/JAT SCALE: 1" = 20' 20' 0 20' 40' GRAPHIC SCALE NC GRID NAD 83/2011 DEMOLITION PLAN1SCALE: 1" = 20' DEMOLITION NOTES 1. THE CONTRACTOR SHALL VISIT THE SITE TO BECOME FAMILIARIZEDWITH FIELD DEMOLITION CONDITIONS. 2. THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER DISPOSAL OF ALLDEMOLISHED DEBRIS ASSOCIATED WITH THE PROJECT INACCORDANCE WITH THE PROJECT SPECIFICATIONS. 3. THE CONTRACTOR IS RESPONSIBLE FOR CONTROLLING DUSTGENERATED BY THE WORK, INCLUDING BUT NOT LIMITED TODEMOLITION AND CONSTRUCTION ACTIVITIES, SITE VEHICULARTRAFFIC AND RELATED OPERATIONS. 4. THE CONTRACTOR IS RESPONSIBLE FOR HAVING ALL EXISTINGUTILITIES LOCATED PRIOR TO BEGINNING ANY DEMOLITION.CONTRACTOR SHALL CONTACT NC ONE CALL AT LEAST 72 HOURSPRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVEEXISTING UTILITIES LOCATED. 5. EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUNDAND ABOVE GROUND, ARE BASED ON FIELD SURVEY AND THE BESTAVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFYFIELD CONDITIONS PRIOR TO BEGINNING RELATED CONSTRUCTION.ANY DISCREPANCIES SHALL BE REPORTED TO THE OWNER'SREPRESENTATIVE AND ENGINEER IMMEDIATELY. 6. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OFDISCONNECTING AND ABANDONING ALL EXISTING UTILITIES WITH THEOWNER UNLESS OTHERWISE NOTED. ALL EXISTING UTILITIES ANDASSOCIATED PIPING, ETC. NOT IN USE ON THE SITE SHALL BEPROPERLY ABANDONED AND REMOVED AS REQUIRED. COORDINATEWITH THE OWNER. 7. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ANYEXISTING UTILITIES THAT REMAIN IN SERVICE DURING DEMOLITION. 8. THE CONTRACTOR IS RESPONSIBLE FOR STABILIZATION OF ALLDISTURBED AREAS AND SLOPES ON AND OFF SITE IN ACCORDANCEWITH THE EROSION CONTROL MEASURES SPECIFIED ON THE PLANSAND IN THE SPECIFICATIONS. THE CONTRACTOR SHALL COORDINATEWITH THE OWNER TO DETERMINE WHO IS RESPONSIBLE FORPROVIDING THE PERMANENT STABILIZATION MEASURES AND THE TYPEOF PERMANENT MEASURES PRIOR TO BEGINNING DEMOLITION ANDCONSTRUCTION. THE PERMANENT STABILIZATION MEASURES SHALLBE IN PLACE AND ACCEPTABLE TO THE OWNER'S REPRESENTATIVEAND ENGINEER PRIOR TO PROJECT CLOSEOUT. COORDINATEINSPECTION WITH THE OWNER AND ENGINEER PRIOR TO PROJECTCLOSEOUT. 9. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING ANDCONTACTING THE ENGINEER FOR THE REQUIRED INSPECTIONS ON THEPROJECT. 10. WETLANDS EXIST ON SITE. WETLANDS WILL NOT BE DISTURBED DURINGCONSTRUCTION OF THIS PROJECT. 9/29/25                                                                                                                                                                    SD SD SD SD SD SD SD SD SD SD SD SD SD SD   2700414.430RBF 1/2"0.6' A.G.BENT, S.A.B.   2723314.41GAS MKR 2723414.35  T T PROPERTY LINES PERDEED BOOK AND PAGE INT E R S T A T E I 4 0 N/FCAROLINA POWER & LIGHT COPIN R03200-004-002-000DEED BOOK 507 PAGE 66LUC: 491-UTILITIESZONING: I-2 18" RCPINV=12.32' 18" RCPINV=12.52' 15" RCPINV=12.54' 15" RCPINV=12.56' 15" RCPINV=13.03' 15" RCPINV=13.11'  W W W W W W W W W W W W W W W W W W W W W                                                                                                                                                      TTTTTTTTT W W    W W W W W W TTTTTTTTTTTTTTT LOD LO D LO D LO D LOD LOD LOD LO D LOD LOD LOD LO D LO D LOD LOD LO D LO D LOD LOD LOD LOD LOD LO D LO D LO D LO D LO D LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LO D LO D LO D LO D LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LO D LOLOD LOD LO D LO D LO D LO D LO D LO D LO D LO D LO D LLO D LO DOD LO D LO D LO D LO D LO D LOD LO D LOD LOLOD LO D LO D LO D LO D LO D W W W D SITE DATA ENGINEER PROJECT OWNER STAMP CHECKED BY PRINCIPAL IN CHARGE REVISIONS ISSUE FOR ISSUE DATE PROJECT ADDRESS PROJECT NUMBER SHEET TITLE SHEET NUMBER www.rivervieweng.com 4904 PARK AVENUEWILMINGTON, NC 28403(910) 398-2882 nlauretta@rivervieweng.com DRAWN BY CO V I N G T O N F L E X SITE PLAN CS101 DESIGN DEVELOPMENT 1026.02 3305 FREDRICKSON RD WILMINGTON, NC 28401 REVIEW - NOT FOR CONSTRUCTION SEPTEMBER 29, 2025 N. LAURETTA, PE, LEED AP NJL DA E B U I L D I N G , I N C . 711 K E R R A V E N U E WI L M I N G T O N , N C 2 8 4 0 3 NJL/JAT SITE PLAN1SCALE: 1" = 20' GENERAL NOTES PROJECT NAME COVINGTON FLEX PROJECT ADDRESS 3305 FREDERICKSON RDNEW HANOVER COUNTY, NC PARCEL ID - PARCEL A RO3200-002-035-000 TOTAL PROPERTY ACREAGE ±0.80 ACAPPLICANT/DEVELOPER DAE BUILDING, INC. ENGINEER RIVERVIEW ENGINEERING, PLLCNICHOLAS LAURETTA, PE, LEED AP ZONING I-2 LAND USE 899 - OTHER SERVICESCAMA LAND USE URBANFLOOD HAZARD ZONE X RIVER BASIN CAPE FEARRECEIVING STREAM TOOMERS CREEKCLASSIFICATION WS-IV SETBACKS (SEE NOTE 5)REQUIRED PROVIDEDFRONT5050SIDE STREET 00 SIDE INTERIOR 00REAR00PROPOSED STRUCTURES NUMBER OF BUILDINGS 1BUILDING SQUARE FOOTAGE 9,600 SF BY-RIGHT HEIGHT N/A BUILDING HEIGHT TBDCONSTRUCTION TYPE TBDBUILDING LOT COVERAGE 33% IMPERVIOUS COVERAGE EXISTING 2,085 SF PROPOSED 19,678 SF PROPOSED OFFSITE 0 SFDISTURBED AREA 0.88 ACRESPARKING SUMMARY INTENSITY REQUIRED PROVIDED WAREHOUSING (1.5 PER 1000 SF)10,400 16 15 ADA COMPLIANT PARKING 11 FLOOD PLAIN NOTES THE SITE IS NOT LOCATED IN A SPECIAL FLOOD HAZARD AREA ASDETERMINED BY FEMA FLOOD PANEL 3720311900K, EFFECTIVE AUGUST28, 2018. STORMWATER NOTES 1. STORMWATER MANAGEMENT WILL BE DESIGNED IN ACCORDANCEWITH STATE AND NEW HANOVER COUNTY STANDARDS.2. FULL PERMIT APPROVALS WILL BE PROVIDED TO NEW HANOVERCOUNTY WHEN RECEIVED. UTILITY NOTES 1. ALL WATER SERVICES WILL BE PROVIDED BY CFPUA.2. ALL SEWER SERVICES WILL BE PROVIDED BY CFPUA.3. HYDRANTS WILL BE PROVIDED PER NEW HANOVER COUNTYEMERGENCY MANAGEMENT REQUIREMENTS. ENVIRONMENTAL NOTES 1. NO KNOWN HISTORIC OR ARCHEOLOGICAL SITES EXIST ON THESUBJECT PARCEL.2. NO JURISDICTIONAL WETLANDS AND STREAMS EXIST ONSITE. SCALE: 1" = 20' 20' 0 20' 40' GRAPHIC SCALE NC GRID NAD 83/2011 20'x40' 50.0' FRO N T SETBAC K 20'x40' 20'x40' 20'x40' 20'x40'20'x40'20'x40'20'x40'20'x40' 20'x40' 9 37.5' STREETY A R D VARIAB L E W I D T H STREET Y A R D ASPHALT(11,055 SF) 20'x40'20'x40' 4 2 4 . 0 ' 9.0' 18. 0 ' 24. 0 ' R30 ' R20' 24. 0 ' 70'X10' SIGHT DISTANCETRIANGLE (TYP.) LANDSCAPE DATA DISTURBED AREA ± 0.88 ACRES AC.0.88 ACRES * 15 = 14 TREES (2" CAL.) STREETYARD REQUIREMENTS 1 CANOPY TREE OR 3 UNDERSTORY TREESAND 6 SHRUBS PER 600 SF REQUIRED 25' WIDE X 259 LF = 6,475 SF PROPOSED 5,864 SFSHADING REQUIREMENTS 8% REQUIRED 9,798 SF * 0.08 = 784 SF PROVIDED 1,540 SFTRANSITIONAL BUFFER N/A FOUNDATION PLANTINGS 12% OF BUILDING FACE240 LF * 15 FT * 0.12 = 432 SF PROVIDED: 480 SFMITIGATION DOCUMENTED TREES NO TREE REMOVALSIGNIFICANT TREES NO TREE REMOVAL LANDSCAPE NOTES 1. PRIOR TO ANY CLEARING, GRADING OR CONSTRUCTION ACTIVITY,TREEPROTECTION FENCING WILL BE INSTALLED AROUND PROTECTED TREES ORGROVES OF TREES. NO CONSTRUCTION WORKERS, TOOLS, MATERIALS ORVEHICLES ARE PERMITTED WITHIN THE TREE PROTECTION FENCING. 2. THE AREAS WITHIN THE TRIANGULAR SIGHT DISTANCE SHALL BEMAINTAINED FREE OF ALL OBSTRUCTIONS BETWEEN 30" AND 10'. 3. A RAIN/FREEZE SENSOR SHALL BE USED IF THERE IS AN IRRIGATIONSENSOR. 4. ALL PLANT BEDS ARE TO RECEIVE 3-4" OF PINESTRAW OR MULCH. 5. LANDSCAPING SHALL BE COMPLETE BEFORE ISSUANCE OF A CO. BOTANICAL / COMMON NAME CALIPER HEIGHT QTY REMARKS KEY NO.CANOPY TREE 1 PRUNUS CAROLINIANA / CAROLINA CHERRYLAUREL 3" 10' - 12'14 STREETYARD/SHADING2QUERCUS LAURIFOLIA / LAUREL OAK 3" 10' - 12'14 DISTURBED AREA BOTANICAL / COMMON NAME CALIPER HEIGHT QTY REMARKS UNDERSTORY TREE3LAGERSTOREMIA INDICA / CREPE MYRTLE 2" 8' - 10' 2 PARKING LOT ISLAND BOTANICAL / COMMON NAME HEIGHT SPREAD SPACING QTY REMARKSSHRUBS 4 ILEX VOMITORIA NANA / DWARF YAUPON 24" 24" 4' O.C.33 STREETYARD5ILEX VOMITORIA / YAUPON HOLLY 3' O.C.33 STREETYARD6DISTYLIUM BLUE CASCADE 52 FOUNDATION BOTANICAL / COMMON NAME QUANTITY REMARKS GROUND COVERCYNODON DACTYLON / BERMUDA GRASS PLANT SCHEDULE INFILTRATIONBASIN 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 4 5 4 5 4 5 4 5 4 5 4 5 4 5 4 5 4 5 4 5 6 6 9/29/25 OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHEOHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE                                                                                  SD SD SD SD SD SD SD SD SD SD SD SD SD SD GWGW GW GW GW 2717516.04LP GW GW T T NA PO W E R & L I G H T C O 0-004 - 0 0 2 - 0 0 0 K507 P A G E 6 6 LITIE S 18" R C P INV = 1 2 . 3 2 ' 18" R C P INV = 1 2 . 5 2 ' 15" R C P INV = 1 2 . 5 4 ' 15" R C P INV = 1 2 . 5 6 ' 15" R C P INV = 1 3 . 0 3 ' 15" RC INV = 1 3 W W W W W W W W W W W W W W W W W W W W W 10+00 11+00 12+00 13+00 14+00 14+50 10 + 0 0 11+00 11+6 3 . 7 4 70L F O F 1 5 " R C P @ 0 . 4 3 % 16 15 14 1312 12131415 16 15.5 15.5 15.5 15 16 TRENCH DRAIN 19 L F O F 1 2 " HD P E @ 2 . 4 5 % LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLOD LOD LODLOD LOD LOD LODLODLODLODLODLOD LOD LO D LOD LO D LOD LOD LO D LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLOD 48LF OF 12" HDPE @ 0.00% 13 OHE OHE OHEOOOHELODODOOLODLODEELOLODDDDLODLODODLDLODOHEOHEOHEOHEDLODLODLOD OHEOHEOHE OHEOHE OHEOHE OHEOHEOHE OHEOHE HHEHE 19 L F O F 1 2 OFOF LF HD P E @ 2 E @@ PE EL E V A T I O N EL E V A T I O N STATION 10 15 20 10 15 20 10+00 11+00 12+00 13+00 14+00 14+50 EL E V A T I O N EL E V A T I O N STATION 13 15 20 13 15 20 10+00 11+00 11+75 2.00%-0.50% EL E V . 1 6 . 3 7 ST A 1 0 + 8 2 . 2 6 EL E V . 1 5 . 9 7 STA 1 1 + 6 3 . 7 5 EL E V . 1 5 . 3 9 ST A 1 0 + 3 3 . 1 1 ENGINEER PROJECT OWNER STAMP CHECKED BY PRINCIPAL IN CHARGE REVISIONS ISSUE FOR ISSUE DATE PROJECT ADDRESS PROJECT NUMBER SHEET TITLE SHEET NUMBER www.rivervieweng.com 4904 PARK AVENUEWILMINGTON, NC 28403(910) 398-2882 nlauretta@rivervieweng.com DRAWN BY CO V I N G T O N F L E X DRIVEWAY GRADING PLAN CS102 DESIGN DEVELOPMENT 1026.02 3305 FREDRICKSON RD WILMINGTON, NC 28401 REVIEW - NOT FOR CONSTRUCTION SEPTEMBER 29, 2025 N. LAURETTA, PE, LEED AP NJL DA E B U I L D I N G , I N C . 711 K E R R A V E N U E WI L M I N G T O N , N C 2 8 4 0 3 NJL/JAT SCALE: 1" = 20' 20' 0 20' 40' GRAPHIC SCALE NC GRID NAD 83/2011 DRIVEWAY GRADING PLAN1SCALE: 1" = 20' NCDOT STANDARD DRAWINGS PART OF THIS SET BY REFERENCE NCDOT DETAIL DWG NO. WORK ZONE ADVANCE WARNING SIGNS 1101.01 TEMPORARY LANE CLOSURES 1101.02 TRAFFIC CONTROL DESIGN TABLES 1101.11 PORTABLE WORK ZONE SIGNS 1110.02 PAVEMENT MARKINGS - LINE TYPES AND OFFSETS 1205.01 TEMPORARY SILT FENCE 1605.01 MATTING INSTALLATION 1631.01 COIR FIBER BAFFLE 1640.01 NCDOT NOTES 1. CONTRACTOR SHALL BE RESPONSIBLE FOR UTILIZING ALL APPLICABLEAND CURRENT NCDOT STANDARD DRAWINGS INCLUDING, BUT NOTLIMITED TO, THE DRAWINGS INCLUDED OR REFERENCED WITHIN THESEPLANS AND THE APPROVED PERMIT PACKAGE. 2. UPON SUBSTANTIAL PROJECT COMPLETION, CONTRACTOR TO CLEAREXISTING CULVERTS/PIPES, CATCH BASINS, AND DITCHES ALONGFRONTAGE AND DOWNSTREAM AS NECESSARY TO ACHIEVE POSITIVEDRAINAGE. 3. ALL PROPOSED OR RELOCATED SIGNAGE SHALL BE PLACED ORREPLACED IN ACCORDANCE WITH NCDOT APPROVED BREAKAWAY SIGNSUPPORTS AS DETAILED IN DIVISION 12 IN THE NCDOT STANDARDDRAWINGS. 4. CONTRACTOR TO SAWCUT EXISTING ASPHALT FOR SMOOTH JOINT NOTALIGNED WITH WHEEL PATH. FREDRICKSON ROAD PROFILE2SCALE: HOR 1" = 20' VER 1" = 2' DRIVEWAY PROFILE3SCALE: HOR 1" = 20' VER 1" = 2' 2" SF9.5C SUPERPAVE HOT MIX ASPHALT SURFACE COURSE (NCDOT SPECIFICATION) 8" AGGREGATE BASE COURSE (NCDOT SPECIFICATION) 1 2 DRIVEWAY SECTION SCALE: NOT TO SCALE4 24.0' ASPHALT 12 ℄ 3' PLAZA1.0% MIN.2.0% MAX. FILL S L O P E (MAX. 2 : 1 ) CUT SL O P E (MAX. 1 . 5 : 1 ) FILL SL O P E (MAX. 2 : 1 ) CUT S L O P E (MAX. 1 . 5 : 1 ) -0.02 FT/FT-0.02 FT/FT EDGE OF PAVEMENT 3' PLAZA1.0% MIN.2.0% MAX. 8" AGGREGATE BASE COURSE(NCDOT SPECIFICATION) NCDOT DRIVEWAY PAVEMENT SECTION SCALE: NOT TO SCALE 2" SF9.5C SUPERPAVE HOT MIXASPHALT SURFACE COURSE(NCDOT SPECIFICATION) 5 12" COMPACTED SUBGRADE(98% OF MAXIMUM DRY DENSITY ASTM D-698) 70'X10' SIGHT DISTANCETRIANGLE (TYP.) 22 . 9 ' 34. 6 ' 75.7' R3 0 ' 63. 1 ' 69. 9 ' 35 . 3 ' END OFPAVEMENT EXISTINGDRIVEWAY EXISTINGDRIVEWAY SUTTON STEAMPLANT ROAD EXISTINGDRIVEWAY EXISTING DRIVEWAYTO BE WIDENED 24.0' 350.0' LIMITS OF SIGHTDISTANCE POSTED SPEED LIMIT 350.0' 3.5 ' 9/29/25 NCDOT | Division 3 | District 3 Project Name:_____________________________ Date:_______________ Applicant Checklist NCDOT Checklist Driveway Application Process and Site Plan Requirements ALL APPLICATIONS SHALL BE ACCOMPANIED BY COMPLETE AND DETAILED SITE PLANS THAT ADHERE TO THE POLICIES LISTED IN THE POLICY ON STREET AND DRIVEWAY ACCESS TO NORTH CAROLINA HIGHWAYS AND THIS DOCUMENT. FAILURE TO ADHERE TO THESE POLICIES WILL RESULT IN THE RETURN OF THE APPLICATION TO THE APPLICANT FOR REVISION. ***THE NCDOT WILL NOT BEGIN THE REVIEW PROCESS ON INCOMPLETE APPLICATIONS*** Electronic Pre-Submittals In an effort to save time and resources, we are happy to provide an initial assessment of a driveway permit submittal’s plans via email to identify any major issues up front. This initial assessment can be followed up with a submittal of one digital copy of the plans along with all other required documents. All Permit applications shall be submitted through the online portal https://connect.ncdot.gov/site/Permits/Pages/default.aspx In the notify email section of the portal application please include the District Office email (Div3Dist3@ncdot.gov). See the last pages for further instruction. Online resources: •NCDOT Policy on Street and Driveway Access to North Carolina Highways: https://connect.ncdot.gov/projects/Roadway/RoadwayDesignAdministrativeDocuments/Policy%20on%20Street%20an d%20Driveway%20Access.pdf •NCDOT Policies and Procedures for Accommodating Utilities on Highway Rights of Way: https://connect.ncdot.gov/municipalities/Utilities/Pages/UtilitiesManuals.aspx •Electronic Forms Database: https://connect.ncdot.gov/Pages/default.aspx 1) a.Cover Letter Include contact information for applicant and engineer, including email address, mailing address, and phone number. Include the parcel number(s), description of all phases of the development and future land uses to be served by the permit, and a description of the adjoining land owned or controlled by the applicant. b.NCDOT Street and Driveway Access Permit Application (form downloadable via link below) https://connect.ncdot.gov/resources/BusinessForms/TEB-65-04.doc c.$50.00 Inspection Fee Per Access Point Attach to Permit Application form (not applicable for municipalities, churches, and schools) d.NPDES Stormwater Permit Compliance Certification (form downloadable via link below) https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/NPDESstatement.doc e.Verification of Compliance with Environmental Regulations (form downloadable via link below) https://connect.ncdot.gov/municipalities/Utilities/EncroachmentForms/VCER-1.pdf f.Site Plans (to include the “Master Plan” of a tract even if only a small portion is being developed first) Additional site plan requirement details can be found in section 2 of this document. g.Design Plan Requirements for projects involving roadway improvements If roadway improvements are required as part of the permit, then roadway plans, pavement marking plans,signing plans, and traffic control plans will be required - See Section 6 for more information Y N n/a Engineering Studies The applicant may be required by the District Engineer to submit studies based on, but not limited to, the parameters outlined herein. If study requirements of the local government agency are more restrictive than the NCDOT requirements, then local government requirements will govern. However, this does not imply that the NCDOT is obligated to approve entrance designs that are too constrictive to allow smooth and safe traffic flow. All studies including, but not limited to, Traffic Impact Analyses (TIA), traffic signal studies, and drainage studies, must be prepared under the direct charge of and sealed by a North Carolina licensed Professional Engineer. Section 1: Requi red Documents |Required documents to accompany all Initial Driveway Application Submittals Please note that these are the minimum requirements of all driveway permit applications. All required documentation shall be submitted through the online portal as PDF files, with the exception of the Performance and Indemnity Bond and the $50 Inspection Fee(s), these should be mailed or delivered to 5501 Barbados Blvd, Castle Hayne, NC 28429. If a Traffic Impact Analysis and/or roadway improvements are deemed necessary as a condition of the permit, there may be additional submittal materials required. State of North Carolina | Department of Transportation | Division 3 | District 3 5501 Barbados Blvd, Castle Hayne, NC 28429 Form Updated 10/15/2021 (910) 398-9100 T NCDOT Permit #___________________ Y N n/a Section 1: Required Documents (continued) 2)Required documents to accompany all Driveway Applications PRIOR TO FINAL APPROVAL a.Site Plans One (1) digital copy (PDF) unless otherwise requested by the District Office. Additional site plan requirement details can be found in section 2 of this document. b.Performance and Indemnity Bond Information/Forms See last page of document for bond information and forms c.Performance and Indemnity Bond Amount 100% of the cost of the work within NCDOT Right-of-Way (R/W) based on the attached estimate determined by the applicant's engineer and approved by the District Engineer. Bond hold letter required for for municipalities, churches, and schools. See pages 101-105 in the Policies and Procedures for Accommodating Utilities on Highway Rights of Way for acceptable bond types d.Radius Encroachment Letter (if applicable) If driveway radius encroaches on the frontage of an adjacent property, a Radius Encroachment will be required e.Hold Harmless Letter (if applicable) If the Permit is within the limits of an active NCDOT project, a Hold Harmless letter from the NCDOT contractor will be required. If the project is in preconstruction, coordinate with the Department's Project Development Unit Section 2: General Site Plan Requirements | All site plans shall include and show, at a minimum, the items listed below Page numbers reference the NCDOT Policy on Street and Driveway Access to North Carolina Highways 1)Drawn to a scale of 20, 30, 40, or 50 feet per inch and the scale shall be shown 2)North arrow, vicinity map, date of plan, and date of most-recent revision if applicable 3)Contact information of applicant and engineer, including mailing address, phone number, and email address 4)Show R/W lines, highway control of access, and property lines 5)All existing utilities (including handholes) and easements 6)R/W width 7)Existing posted speed limit(s) and design speed limit(s) 8)Show all property lines, intersections, signals, signal loops, railroads, or crossovers within 500’ in all directions of the property lines of the proposed development 9)Show location of sidewalks, crosswalks, greenways, multi-use paths, curb ramps, railroads, bus stops, and any other relevant transportation facilities in the development area 10)Include a plan sheet showing full site build-out and land use 11)Buildings shown with “gross leasable area” 12)Width of property frontage 13)Distance from R/W to buildings and gasoline service islands 14)Distance from R/W to existing/proposed Edge of Pavement (EOP) (pages 32 & 34) 15)All streams, bridges, retaining walls, signs, or other fixed objects such as trees, utility poles, traffic signals, etc. Section 3: Driveway Plan Requirements | All driveway plans shall include and show, at a minimum, the items listed below 1)Provide comprehensive survey within the existing R/W on both sides of the road for a distance of 500’ in all directions from the development’s property lines. Provide additional hydraulic survey data to the nearest storm water inlet/outlet including ditch lines and storm water pipes, if located outside of the 500' distance. 2)Lane configurations and widths of all existing and proposed driveways, roadways, and adjacent roadways 3)All driveway widths (2-way: 20’ minimum, 36’ maximum | 1-way: 12’ minimum, 24’ maximum | with island: 14'ingress, 18' egress) (pages 50 & 77) 4)Driveway Profile - In shoulder sections, maintain minimum 2% fall from edge of travel way for required shoulder width distance Primary: 8’ minimum | Secondary: 6’ minimum 5)All existing and/or proposed driveway radii (20’ minimum, 50’ maximum, 30’ typical) (pages 34 & 51) In curb and gutter sections, use City of Wilmington flare (SD 3-03.3) - (see attached) In shoulder sections, show grades at the EOP and centerline 6)No curbing is allowed within NCDOT R/W along shoulder sections except as part of a driveway island (page 31) 7)Driveway angles of approach to existing roadway (90° preferred, 75°-90° required for 2-way driveways, 45°-90° allowed for right-in/right-out on a case-by-case basis) (page 51) 8)Driveway Profile (pages 42- 43) Y N n/a Y N n/a □□ □□ □ □ Y N n/a Y N n/a Y N n/a Y N n/a Section 3: Driveway Plan Requirements (continued) 9)Driveway Pavement Cross Section (to be in place from EOP to edge of R/W) Asphalt: 8” ABC stone and 1.5” S9.5B Concrete: 6” of concrete 10)Driveway Offset (driveway EOP to property line; page 75): Minimum: 20’ 11)Corner Clearance (radius point to radius point; page 52)Minimum: 50’ Desirable: 100’ or Municipal std. 12)Minimum 10’x70’ sight triangles at driveways (measured from and along the R/W line) (page 31) 13)Sight Distance (length of sight-distance in both directions shown for each driveway; pages 27-29) 14)Driveways should be aligned with existing opposing driveways or correct offset should be provided (pages 40-41) 15)Distance between driveways being requested (if applicable; page 51) 16)Minimum internal storage areas with specified queues (pages 31-33) 17)Minimum protected driveway stem(s) provided and indicated (pages 33-34) 18)Indicate any gated entrances (100’ minimum setback from R/W required) - traffic queuing study may be required | Section 6: Roadway Plan Requirements If off-site improvements are required, roadway plans shall show, at a minimum, the items below 1)Full width typical sections must be shown (paved shoulders to match the typical section of the adjacent roadway) 2)Minimum Asphalt Typical Section (for turn lanes and/or paved shoulders) Adjacent recently-completed or upcoming TIP projects w/ different typical sections may supersede those below •Primary Routes (US & NC) and Secondary Routes with Annual Average Daily Traffic (AADT) ≥10,000 5.5” B25.0C, 3” I19.0C, 1.5” S9.5C; any overlay of existing pavement is to be a minimum of 1.5” S9.5C •Secondary Routes with AADT<10,000 5.5” B25.0C, 1.5” S9.5B; any overlay of existing pavement is to be a minimum of 1.5” S9.5B 3)Pavement overlay is required if modification of existing pavement markings and/or lanes is necessary The grinding of pavement markings will not be allowed 4)Shoulder Widths (Paved + Unpaved) Primary: 8’ minimum | Secondary: 6’ minimum 5)Ditch Slopes - front and back slopes - minimum 3:1 or flatter 6)Indicate existing roadway grade 7)All taper lengths and deceleration lengths should be appropriately designed for the given design speed (page 78) 8)All turn lanes should be designed according to the Driveway Manual and Roadway Standard Drawings (page 79) See 1205.04 Sheets 1 & 2 and 1205.05 Sheet 1 of the Roadway Standard Drawings for details 9)Pavement marking and signing plans are required - plans must be approved by Division Traffic Services 10)Traffic control plans are required - Detailed phasing plans may be required based on project type and location 11)New and/or revised signal plans must be included for new installations and if signal modifications are required All signal plans must be reviewed and approved by Division Traffic Services and the Signal Design Unit. A Traffic Agreement must be completed to facilitate the review. Contact Division Traffic Services at (910) 341-2200. | Section 4: Drainag e Requirements All drainage features on NCDOT Right-of-Way shall adhere to, at a minimum, the items listed below Section 5: Internal Circ ulation Requirements |All internal circulation details shall adhere to, at a minimum, the items listed below 1)Interior driveway channelization stems Minimum 100’ from the ROW or at the discretion of the District Engineer 2)Traffic flow pattern 3)Traffic control devices 4)Pavement Markings Y N n/a Y N n /a Y N n/a Y N n/a Y N n/a Y N n/a Y N n/a Y N n/a 1)Pipe Cover Minimums (measured from top of pipe to subgrade) High Density Polyethylene (HDPE): 24” | Corrugated Aluminum (CAP): 12” | Reinforced Concrete (RCP): 12” 2)Pipe End Treatment (see Roadway Design Manual 5-20, B-2) Pipes ≤24" on multilane highways posted above 45mph require Parallel Pipe End Sections See 310.02 and 310.04 of the Roadway Standard Drawings for details Pipes >30" on multilane highways posted above 45mph require guardrail Pipes ≥36" require an endwall on the inlet end 3)All proposed Drainage is to be provided inside existing R/W. Otherwise, additional R/W or a permanently dedicated drainage easement will be required to accommodate the proposed project drainage 4)All sizes, types, and invert elevations of existing/proposed pipes and drainage structures must be shown(see Sec.3 #1 for survey requirements) 5)Provide spot elevations along frontage of driveway (at EOP and centerline) 6)Provide grades and spot elevations for existing and proposed ditches 7)Show how drainage will be accommodated along property frontage(District Engineer may require applicant to provide drainage calculations when warranted) C/L EOTEOP P/L R/WR/W R/W EOP EOP EOP EOP NTS R/W P/L DRAINAGE FLOW DRAINAGE FLOW DRAINAGE FLOW SHOULDER WIDTH SHOULDER WIDTH SHOULDER WIDTH SHOULDER WIDTH S IGHT T R IANG LE 10 ' BY 70 'S I GHT T R I ANGL E10' B Y 70' DRIVEWAY RR MIN. 30'MIN. 30' NO ROADWAY IMPROVEMENT COMMERCIAL DRIVEWAY WITH NORMAL CROWN ROADWAY 6" LOWER THAN THE EDGE OF PAVEMENTMIN 2% FALL AWAY or 20' AWAY FROM THE PROPERTY LINEDRIVEWAY SHALL BE LOCATED AT LEAST PIPE/TYPE/SIZE WIDTH CON CR ET E /ASP HA LT LOCAL NAME ROAD POSTED SPEED ( ) MPH WIDTH WIDTHSR NUMBER SITE ADDRESS:TAX PARCEL # 20191115 PARALLEL END S.D. 310.02 INVERT ELEVATION PARALLEL END S.D. 310.02 INVERT ELEVATION 20' AWAY FROM THE PROPERTY LINEDRIVEWAY SHALL BE LOCATED AT LEAST OR 500' OF XYZ SURVEY DATA PAST THE PROPERT LINENEAREST OUTFALL ELEVATION OR 500' OF XYZ SURVEY DATA PAST THE PROPERT LINENEAREST OUTFALL ELEVATION 3008 N Kerr Ave – Flex Space – TRC Review Page | 1 To: Mark N Hargrove, PE, Port City Engineers, PLLC From: Katherine May, Development Review Planner Date: November 5, 2025 Technical Review Committee (TRC) PID#: R03400-001-028-000 Egov# SITECN-25-000103 Subject: 3008 N Kerr Ave – Flex Space - TRC Review Technical Review Committee (TRC) General Information The TRC is a staff-level group of local government officials that reviews projects for compliance with the local regulations administered by each respective review agency. Voluntarily participating state agencies may also provide comments. And general information and non-binding recommendations about the site may also be provided by government agencies. The TRC meetings are considered staff meetings and are not public hearings. The TRC meeting is an opportunity for applicants to speak with county staff and any voluntarily participating state or federal agencies about the review comments they have been provided. No voting is involved in the TRC process, and no final approvals or denials are made at the TRC meetings. Following the TRC meeting, applicants are responsible for updating their plans to address review comments. Those revised plans need to be resubmitted to the assigned case planner. The case planner will facilitate additional reviews until all comments have been addressed, and the necessary departments have stated the plans comply with the applicable minimum requirements for development. Following any future TRC approval, the project is required to obtain additional permits to include a zoning compliance permit for the site. Applicants are also responsible for coordinating with state and federal agencies for compliance with any additional requirements. Any activity on the property that is not approved as part of the TRC review and zoning compliance permit will be considered a violation of the UDO and subject to enforcement action under Article 12 Violations and Enforcement. 3008 N Kerr Ave – Flex Space – TRC Review Page | 2 The following comments have been received for the November 5, 2025, TRC meeting. Additional comments may be made upon further review of subsequent revisions. Planning, Katherine May 910-798-7443 Compliance with local UDO requirements 1. General Comments a. Zoning district – I-2, Heavy Industrial b. The project is not associated with a rezoning but previously received site plan approval on March 11, 2021. Due to the lapse in time from the previous approval, the project must be reviewed again. c. As stated in the application the intended use is warehousing. The Unified Development Ordinance (UDO) defines the use as i. The storing of goods, wares, and merchandise within an enclosed building, whether for the owners or others. There is little on-site sales activity with the customer present. Uses include: cold storage facilities (including frozen food lockers); distribution warehouses (used primarily for temporary storage pending distribution in response to customer orders); storage warehouses (used for storage by retail stores such as furniture and appliance stores); warehouse storerooms; or similar uses. d. The Planning and Land Use Department’s review of the site is for compliance with the UDO and use specific requirements of the specified land use. Any other activity that might occur on the property beyond the definition above should be noted on the application and site plan for additional review and comment. e. There does not appear to be Duke Energy Transmission Lines/Easement on the Property. 2. UDO Section 5.1, Parking and Loading a. Warehousing requires 1.5 parking spaces for every 1,000 square feet of building area. Project proposes 7,070 square feet. Required parking is 7,070 / 1,000 = 7.07 x 1.5 = 10.6 required parking spaces. The site plan shows 17 spaces which meets the minimum required parking. b. Location of the loading area is missing. Please see 5.1.5.B for the dimensional standards. 3008 N Kerr Ave – Flex Space – TRC Review Page | 3 3. UDO Section 5.2, Traffic, Access and Connectivity a. Please note that no building permit for any structure shall be issued which requires NCDOT approval for a Driveway Permit until NCDOT has issued the permit approval. Evidence of approval shall accompany the application for building permit. b. Include the WMPO’s estimated AM and PM traffic generation. If either AM or PM peak hour exceeds 100 trips, state a TIA is required. 4. UDO Section 5.3, Tree Retention a. The site looks to be cleared, please confirm that no trees will be removed. b. Note: Land disturbance permits can be issued by county Engineering before a Tree Removal Permit is approved by Planning. However, any trees removed before the Tree Removal Permit is issued may result in enforcement action under Section 5.3.2 of the Unified Development Ordinance to include prohibiting any development of the site for 3 to 5 years. 5. UDO Section 5.4, Landscaping and Buffering a. The project is surrounded by commercial zoning, so no buffers are required. b. Dumpsters and loading areas must be screened out of view of any public right-of-way. The plan shows the dumpster is sufficiently screened and the details are included on page C-7.1. c. Per table 5.4.5.C: Standards for Parking Lot Interiors a. Landscaped areas in the interior of parking lots shall be equal to eight percent of the total area to be used for parking, loading, automobile sales, driveways, internal drive aisles, and other vehicular or pedestrian use. b. The landscaped islands meet minimum length requirements c. At least 75 percent of trees required for interior landscaping shall be of a shade/canopy species. This requirement has been met. d. Table 5.4.6.B: Street Yard Area Standards a. For the I-2 district, 25 square feet for every linear foot of street yard frontage is required with a minimum of 12.5 feet and a maximum of 37.5 feet. This requirement has been met. b. For every 600 square feet of street yard area on average, the following landscaping shall be provided: One canopy/shade tree or if overhead power 3008 N Kerr Ave – Flex Space – TRC Review Page | 4 lines are located above the street yard, three (3) understory trees; and Six shrubs, 12 inches in height at time of planting i. 2550 sf / 600 sf = 4.25 ii. 3 shade trees and 3 understory trees are provided, which meets the minimum requirements. The shrubs also meet the minimum requirements. 6. UDO Section 5.5, Lighting a. Please note that a lighting plan is not required for TRC approval but will be required prior to issuance of construction plan approvals. b. Is any lighting proposed for the site? 7. UDO Section 5.6, Signs a. I didn’t see any signs proposed, please confirm. b. For any signs on the site, a separate sign permit must be submitted and reviewed by the county for compliance with Section 5.6 of the UDO for standards at or after the submittal of the separate zoning compliance and construction permits for the primary building or use. Any approvals granted by the TRC for the site design is not an approval for the ultimate size or placement of the sign. 8. UDO Section 5.7, Conservation Resources a. The conservation resources map does not indicate any conservation resources impacting the property, this section does not apply. 9. UDO Article 9, Flood Damage Prevention a. The property is not in a flood plain. NHC Fire Services, Ray Griswold 910-798-7448 Compliance with NC Fire Code 1. Fire extinguishers per NFPA 10 2. Fire finals required NHC Engineering, Galen Jamison 910-798-7072 Stormwater management and land disturbance 1. Please submit for permit revisions to County stormwater permit STMW-20-0043 and land disturbance permit LNDP-20-00133. Please digitally submit the permit applications 3008 N Kerr Ave – Flex Space – TRC Review Page | 5 documentation with requisite review fees to the COAST online permit portal (https://newhanovercountync-energovpub.tylerhost.net/apps/selfservice#/home) using the referenced permit numbers 2. All conveyance calculations will need to be updated per the latest NHC stormwater design manual. 3. Please contact the State for their stormwater permit requirements. NHC Environmental Health, Dustin Fenske 910-798-6732 Septic tanks and wells 1. Site plan reflects connection to public water and sewer. Records reflect the site is surrounded by parcels that are connected to public water and sewer. No septic or well issues are apparent for this site design. NHC Addressing, McCabe Watson 910-798-7068 Street naming and property address 1. Each suite will need its own individual address. 2. Please contact me for address assignment following TRC approval. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 Public water and sewer 1. CFPUA TRC Comments provided are preliminary comments only. 2. CFPUA is moving toward becoming paperless. When ready to submit plan review package, upload all documents to https://www.cfpua.org/FormCenter/Engineering-3/Engineering- Plan-Review-103. 3. CFPUA water and sewer available 4. Capacity is dependent on the analysis of the pipe collection system (gravity and force mains) 5. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE Application Form and a Preliminary Plan, this determination does not guarantee capacity. 6. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the Authority. 3008 N Kerr Ave – Flex Space – TRC Review Page | 6 NCDOT, Nick Drees 910-343-3915 Driveway access and state road improvements 1. See attached comments. WMPO, Caitlin Cerza 910-473-5130 New Hanover County contracted traffic engineering services comments: 1. See attached comments. Army Corps of Engineers, Brad Shaver 910-251-4611 Information or Requirements if wetlands are impacted 1. No comments. Project information also provided to the following state agencies and non-regulatory local agencies for their awareness: New Hanover County Emergency Management New Hanover County Schools NC Department of Environmental Quality (DEQ) NC DEQ Division of Coastal Management NC DEQ Division of Energy, Mineral, and Land Resources New Hanover County Sustainability Manager NHC Soil & Water Conservation MEMORANDUM To: New Hanover County Technical Review Committee Date: October 9, 2025 Subject: 3008 N Kerr Avenue Flex Space Comments: • N/A NCDOT Projects: • N/A WMPO 2045 MTP Projects: • N/A New Hanover County Projects: • N/A TIA: Based on the 11th edition ITE Trip Generation Manual, a TIA is not required. Land Use (ITE Code) Intensity Unit 24 Hour Volumes AM Peak Hour Trips PM Peak Hour Trips Warehousing (150) 9000 Square Feet 53 25 28 STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION JOSH STEIN DANIEL H. JOHNSON GOVERNOR SECRETARY Mailing Address: NC DEPARTMENT OF TRANSPORTATION DIVISION OF HIGHWAYS 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUIT 101 WILMINGTON, NC 28403 Memorandum DATE: October 13, 2025 TO: New Hanover County Technical Review Committee SUBJECT: Flex Space – 3008 North Kerr Avenue ________________________________________________________________________ These are preliminary comments and are based on the plans as submitted for the proposed site. They are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. General Comments: NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT Online Portal.https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx You can coordinate with the District Office with any questions 910-398-9100. NCDOT Driveway Permit: A change of ownership can be done for the proposed site. • Contact Frank Mike for additional details and/or requirements. NCDOT Encroachment Agreement: An NCDOT Encroachment Agreement is required for any utility connections or installations within the NCDOT right-of-way (form 16.6). • Refer to the NCDOT UAM Manual and the NCDOT encroachment checklist for required documents and site plan information. An NCDOT Encroachment Agreement is required for any sidewalk or multi-use paths installed within the NCDOT right-of-way (form 16.6). Mailing Address: NC DEPARTMENT OF TRANSPORTATION DISTRICT 3 ENGINEER’S OFFICE 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Site Plan Comments: Drainage/Stormwater Conveyance: • If the drainage does not naturally flow to the NCDOT right of way the historic drainage pattern should be maintained. NCDOT Standard Drawings: • Include/update the NCDOT Standard Drawings (2024) that are applicable to the development. Sight Triangles and Sight Distance: • Show and label the 10’ X 70’ NCDOT sight triangles. o No obstructions shall be placed within the NCDOT sight triangles. • Show and label the stopping sight distance. o No obstructions shall be placed within the stopping sight distance. Identification Signing and Landscaping: • Identification signing or landscape vegetation within the median and the sight distance triangle must not obstruct the driver’s line of sight. No landscaping or signing will be allowed to exceed 42 inches in height, measured from the Edge of Pavement (EOP) within the median or sight triangle. • All pylon signs in the median or sight distance triangle must provide a vertical clear sight zone between 3 feet-6 inches and 10 feet-0 inches measured from the EOP. Signing located within a clear recovery area shall be of a “breakaway design.” • Only low growing shrubbery, consistent with the NCDOT’s landscaping policies, as contained in the publication “Guidelines for Planting Within Highway Right of Way,” will be allowed within a landscaped median and the sight distance triangle at the entranceway to a development, whether the street or driveway connection to the State Highway System is designated as a public facility or not. Landscaping within the right-of-way and sight distance triangles may require additional approval by the District Engineer. Gated Entrances: • Show and label any proposed gates with distances to the right of way line. Site Development For SEPTEMBER, 2025 WILMINGTON, NORTH CAROLINA 3008 N KERR LLC 11763 ASHTON ROAD BURGAW, NC 28425 TEL: 910-378-7610 vinceb@burgesscorporation.net PORT CITY CONSULTING ENGINEERS, PLLC 6216 STONEBRIDGE ROAD WILMINGTON, NC 28409 910-599-1744 LICENSE No. P-1032 mhargrove@ec.rr.com 11" OAK 3008 N KERR AVENUE PRELIMINARY - DO NOT USE FOR CONSTRUCTION No. Checked By Revision Designer Drawn By Date By Scale Date Job No. Sheet No.No. Checked By Revision Designer Drawn By Date By Scale Date Job No.NORTH CAROLINANEW HANOVER COUNTY C-311763 ASHTON ROAD3008 N KERR LLC BURGAW, NC 28425 SITE PLAN3008 N KERR AVENUE FLEX SPACE PORT CITY CONSULTINGENGINEERS, PLLC6216 STONEBRIDGE ROADWILMINGTON, NC 28409910-599-1744 LICENSE No. P-1032 PRELIMINARY - DO NOT USE FOR CONSTRUCTION 1 inch = 20 ft. 20 GRAPHIC SCALE 01020 40