Loading...
HomeMy WebLinkAbout2024-007 Reagan Retail and Office Center_10-23-25SI D E W A L K LYNN AVENUE 50' PUBLIC RIGHT-OF-WAY 175.40'N 80°50'00" W 21 5 . 0 0 ' N 0 9 ° 1 0 ' 0 0 " E 155.00' N 80°50'00" W 11 5 . 0 0 ' N 0 9 ° 1 0 ' 0 0 " E 330.40' S 80°50'00" E 33 0 . 0 0 ' S 0 9 ° 1 0 ' 0 0 " W T EIR EIR EIP EIR EIPP CASTLE AVENUE T FH TT TV MH TOP=21.79' TOP=20.85' TOP=16.50' OHW OHW OHW OHW STREET LIGHT UTILITY MH WV WV GR A V . D / W GR A V . D / W GR A V . D / W GRAV. D/W GRAV. D/W CONC. D/W 36"CMP 36"CMP INV.12.68' INV.12.79' INV.13.71' INV.13.92' <= 1 8 " R C P INV.14.17' GRATE=16.35' <= 1 8 " R C P DI INV.OUT=14.35'(S) INV.IN=14.40(N) GRATE=16.34' DI INV.OUT=13.50'(S) INV.IN=13.35(N) 8"PVC W/L PER CFPUA 8" P V C W / L PE R C F P U A X X X X X X X X X X X XXXXXXXX 26 OAK 16 P I N E 12 O A K 6 M A G N O L I A 19 PINE 17 O A K 15 OAK 8 OAK 21 OAK 11 OAK 26 PINE 28 PINE 5 MAG 11 OAK 12 OAK 11 OAK 11 OAK 18 OAK 12 OAK 36 PINE 11 OAK 36 PINE 36 OAK 8 OAK 12 CEDAR PR O P . P A R K I N G MH 25' 25 ' P U B L I C U T I L I T Y E A S E M E N T DB . 4 3 1 8 / P G . 0 3 1 3 PROP. PARKING 24 PECAN INV.15.66' INV.15.60' 24 " R C P <= 1 5 " R C P 24" RCP INV.=13.45' INV.IN=15.35' <= 1 8 " R C P SE W E R L I N E = > INV.OUT=14.67' (N) INV.IN=14.74' (S) RIM=17.52' SSMH D/W GRAV. D/W CONC. TT T CA S T L E H A Y N E R O A D 4" E I P - D I S T U R B E D 25.00' 10 0 ' P U B L I C R I G H T - O F - W A Y N. C . H W Y 1 3 3 n/f CIRCLE K STORES INC BK 6634, PG 1085 Zoning: B-2 Use: VACANT n/f JEFFREY SUTTON HEIRS ETAL BK 9908, PG 0318 Zoning: B-2 Use: COMMERCIAL n/f TONI L SUTTON BK 5240, PG 0048 Zoning: B-2 Use: COMMERCIAL n/f MCCLURE MEMORIAL PRESBYTERIAN BK 1708, PG 0544 Zoning: B-2 Use: CHURCH n/f NEFTALI BALDERAMA GARCIA BK 6283, PG 2899 Zoning: RA Use: Single Family Residence n/f HILLSBOROUGH STREET LLC BK 6472, PG 1344 Zoning: B-2 Use: COMMERCIAL n/f CAROLINE L. BORDEAUX BK 3665, PG 0818 Zoning: RA Use: Single Family Residence n/f SIMON P PARKIN BK 1536, PG 2092 Zoning: B-2 Use: Single Family Residence 13 14 14 14 14 14 14 14 16 16 16 16 16 16 16 1 6 1 6 1 6 16 16 17 17 17 17 17 17 17 17 17 1 7 1 7 17 17 17 17 17 18 1 8 1 8 1 8 18 1 8 18 1 8 18 18 19 19 1 9 19 21 2 1 21 2 1 22 22 2 2 15 15 15 15 15 15 15 15 15 15 15 20 20 2 0 INV.12.84' INV.12.85' NO EASEMENT LISTED GENERAL UTILITY EASEMENT WIDTH EXISTING BUILDING 1 8 CONTRACTOR TO COORDINATE WITH DUKE POWER FOR POLE RELOCATION SPEED LIMIT 35 MPH SP E E D L I M I T 4 5 M P H C-0 1 EX I S T I N G C O N D I T I O N S , T R E E RE M O V A L / P R O T E C T I O N A N D DE M O L I T I O N P L A N 1" = 30' PROPERTY LINE ADJOINERS TREE PROTECTION FENCE LIMITS OF DISTURBANCE TREES TO BE REMOVED LEGEND EN G I N E E R I N G , P L L C IN T R A C O A S T A L REVISIONS Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 57 2 5 O l e a n d e r D r . U n i t E - 7 Ph o n e : 9 1 0 . 8 5 9 . 8 9 8 3 PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): Em a i l : C h a r l i e @ i n t r a c o a s t a l e n g i n e e r i n g . c o m 2024-007 FO R CLIENT INFORMATION: Reagan, LLC 303 Fox Lake Dr. Clinton, NC 28328 OF 10 JAE CDC CDC 24x36 10/23/2025 Li c e n s e N u m b e r : P - 0 6 6 2 NE W H A N O V E R C O U N T Y , N C RE A G A N R E T A I L A N D OF F I C E C E N T E R SITE CA S T L E H A Y N E R D CASTLE AVE. HOLLY SHELTER R D . PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N SITE DATA PARCEL ID:R01109-001-001-000 CURRENT ZONING:B-2 PROJECT ADDRESS:5901 CASTLE HAYNE RD. CASTLE HAYNE, NC 28429 CURRENT OWNER:REAGAN LLC 303 FOX LAKE DR. CLINTON, NC 28328 TOTAL ACREAGE IN PROJECT BOUNDARY 75,707 S.F. (± 1.74 ac.) EXISTING ONSITE IMPERVIOUS AREAS: (SITE IS VACANT) SOILS TYPE: Ke (Kenansville fine sand) Ls (Lynchburg fine sandy loam) (Per NHC GIS Soil Map) NOTES: 1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY LAND DEVELOPMENT CODE. 2.PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS. 3.EXISTING SURVEYING PERFORMED BY STEVEN L. BUIE, PLS, L-3402. 4.SITE IS LOCATED IN ZONE "X" PER FRIS ON FIRM MAP NUMBER370168 3232 K, EFFECTIVE DATE FEBRUARY 16, 2007. 5.NO WETLANDS, SURFACE WATERS, PROTECTED VEGETATED SETBACKS OR RIPARIAN BUFFERS EXIST ON SITE. 6.PRIOR TO CLEARING, GRADING, OR CONSTRUCTION ACTIVITY, ANY WELLS THAT ARE EXISTING MUST BE PROTECTED AROUND EACH WELL HEAD/CASING AND CAPPED. 7.ALL PINE TREES ARE ASSUMED TO BE LOBLOLLY PINES. ALL GUM TREES ARE ASSUMED TO BE SWEET GUMS. CONTRACTOR TO VERIFY SPECIES PRIOR TO CUTTING. TREE PRESERVATION NOTES: 1.PRIOR TO ANY CLEARING, GRADING, OR CONSTRUCTION ACTIVITY, APPROVED TREE PROTECTION FENCING, SUCH AS SAFETY BARRIER FENCING, A WOODEN SLAT SNOW FENCE OR WIRE FENCE, SHALL BE INSTALLED AROUND PROTECTED TREES OR TREE STANDS LOCATED IN CONSTRUCTION AREAS OR OTHER SITE AREAS THAT WILL BE DISTURBED BY CONSTRUCTION ACTIVITIES. THE FENCING SHALL BE A MINIMUM OF FOUR FEET IN HEIGHT AND BE OF DURABLE CONSTRUCTION. TREE PROTECTIVE FENCING SHALL REMAIN IN PLACE THROUGH COMPLETION OF CONSTRUCTION ACTIVITIES. 2. NO CONSTRUCTION WORKERS, TOOLS, MATERIALS, OR VEHICLES ARE PERMITTED WITHIN THE TREE PROTECTION FENCING. 3.IF AN EXISTING TREE RETAINED TO COMPLY WITH THE STANDARDS OF THIS SECTION IS DESTROYED, SUBSTANTIALLY DAMAGED, OR DIES AS A RESULT OF NEGLIGENCE ON THE PART OF THE PROPERTY OWNER WITHIN THREE YEARS AFTER COMPLETION OF CONSTRUCTION, THEN REPLACEMENT TREES SHALL BE PLANTED ON THE SITE WITH A TOTAL DIAMETER EQUAL TO TWICE THE DIAMETER OF THE RETAINED TREE. A MINIMUM GROWING AREA OF 144 SQUARE FEET SHALL BE PROVIDED FOR EACH REPLACEMENT TREE. IF THE PLANNING DIRECTOR DETERMINES IT IS INFEASIBLE OR FOR REPLACEMENT TREE(S) TO BE ACCOMMODATED ON THE SITE, THEN A PAYMENT MAY BE MADE TO THE COUNTY’S TREE IMPROVEMENT FUND EQUIVALENT TO THE PRICING STANDARDS IN THE COUNTY FEE SCHEDULE. 60'30'15'30'0' Scale: 1"=30' MITIGATION REQUIRED FOR REMOVAL OF SIGNIFICANT TREES QTY SIZE TYPE REPLACEMENT INCHES 2 36"PINE 144.00 1 28"PINE 56.00 1 26"OAK 52.00 TOTAL REPLACEMENT INCHES 252 CREDITS FOR PRESERVED TREES QTY DBH INCHES TYPE DOCUMENTED INCHES SIGNIFICANT INCHES CREDITS 1 26"PINE 26 0.00 1 24"PECAN 24 0.00 1 36"OAK 36 0.00 1 21"OAK 21 0.00 1 18"OAK 18 0.00 1 15"OAK 15 22.50 2 12"OAK 24 36.00 1 11"OAK 11 16.50 1 8"OAK 8 12.00 1 16"PINE 16 24.00 TOTAL INCHES PRESERVED TREES 74 39 TOTAL CREDITS FOR PRESERVED TREES 111.0 LYNN AVENUE 50' PUBLIC RIGHT-OF-WAY T CASTLE AVENUE T FH T T TV MHOHW OHW OHW STREET LIGHT UTILITY MH WV WV GR A V . D / W GR A V . D / W GR A V . D / W GRAV. D/W GRAV. D/W CONC. D/W 36"CMP 36"CMP INV.12.68' INV.12.79' INV.13.71' INV.13.92' <= 1 8 " R C P INV.14.17' GRATE=16.35' <= 1 8 " R C P DI INV.OUT=14.35'(S) INV.IN=14.40(N) GRATE=16.34' DI INV.OUT=13.50'(S) INV.IN=13.35(N) 8"PVC W/L PER CFPUA 8" P V C W / L PE R C F P U A 25 ' S E T B A C K 25' SETBACK 35 ' S E T B A C K 35 ' S E T B A C K X X X X X X X X X X X XXXXXXXX 16 P I N E 12 O A K 6 M A G N O L I A 19 PINE 17 O A K 15 OAK 8 OAK 21 OAK 11 OAK 26 PINE 18 OAK 12 OAK 36 OAK 17 . 5 ' B U F F E R 17 . 5 ' B U F F E R 17.5' BUFFER 14 22 7' S I D E W A L K 15 24 ' 13' 24' R25' 13' 10' X 70' NCDOT SIGHT TRIANGLE (TYP.) 15' 10 ' 39 5 365 275 460 515 37.5' 18' (TYP) 9' (TYP) 9' 9' 9' MH 25' 25 ' P U B L I C U T I L I T Y E A S E M E N T DB . 4 3 1 8 / P G . 0 3 1 3 15' 430 24 ' UP R30 ' R 3 0 ' R 2 5 ' 10' X 70' NCDOT SIGHT TRIANGLE (TYP.) R 2 5 ' R25 ' 24 ' 13 5' SIDEWALK 24 PECAN INV.15.66' INV.15.60' 24 " R C P <= 1 5 " R C P 24" RCP INV.=13.45' INV.IN=15.35' <= 1 8 " R C P SE W E R L I N E = > INV.OUT=14.67' (N) INV.IN=14.74' (S) RIM=17.52' SSMH D/W GRAV. D/W CONC. T T T CA S T L E H A Y N E R O A D 10 0 ' P U B L I C R I G H T - O F - W A Y N. C . H W Y 1 3 3 n/f CIRCLE K STORES INC BK 6634, PG 1085 Zoning: B-2 Use: VACANT n/f JEFFREY SUTTON HEIRS ETAL BK 9908, PG 0318 Zoning: B-2 Use: COMMERCIAL n/f TONI L SUTTON BK 5240, PG 0048 Zoning: B-2 Use: COMMERCIAL n/f MCCLURE MEMORIAL PRESBYTERIAN BK 1708, PG 0544 Zoning: B-2 Use: CHURCH n/f NEFTALI BALDERAMA GARCIA BK 6283, PG 2899 Zoning: RA Use: Single Family Residence n/f HILLSBOROUGH STREET LLC BK 6472, PG 1344 Zoning: B-2 Use: COMMERCIAL n/f CAROLINE L. BORDEAUX BK 3665, PG 0818 Zoning: RA Use: Single Family Residence n/f SIMON P PARKIN BK 1536, PG 2092 Zoning: B-2 Use: Single Family Residence 13 14 14 14 14 14 14 14 16 16 16 16 16 16 16 1 6 1 6 1 6 16 16 17 17 17 17 17 17 17 17 17 17 1 7 17 17 17 17 17 17 17 1 8 1 8 18 18 1 8 18 1 8 18 18 18 19 19 19 1 9 21 2 1 21 2 1 22 22 2 2 15 15 15 15 15 1 5 15 15 15 15 15 20 20 2 0 37.5' PR I M A R Y S T R E E T Y A R D INV.12.84' INV.12.85' NO EASEMENT LISTED GENERAL UTILITY EASEMENT WIDTH R 2 5 ' 10' R25 ' EXISTING BUILDING MATCH EX. ASPHALT ±17.517.2 17.05 17.25 17.8 DI# 1 RIM: 17.65 INV: 16.5 2 18.0 18.95 18.95 18.95 18.5 20.0 18.5 17.8 17.6 MATCH EX. ASPHALT ±18.25 SDMH#1 RIM: 16.8 INV: 15.5 17.45 18" FES#2 INV. 15.3 W/ 5'X10'X12" ED 18" RCP 18 " R C P 260 DUMPSTER PAD & ENCLOSURE (SEE DETAIL) EXIT ONLY - ONE WAY 19 18 17 171819 15" R C P 18.1 SECONDARY STREETYARD 1 8 18 21 20 20.5 20.020 NCDOT DI# 1 RIM: 18.5 INV: 15.5 PROP. 10' PUBLIC D.E. & U.E.15" RCP 18" RCP NCDOT CI# 1 RIM: 17.5 INV: 14.5 NCDOT CI# 2 RIM: 17.5 INV: 14.3 18 NCDOT SDMH#1 RIM: 16.8 INV: 13.6 18" R C P 17.05 30 " R C P 30" NCDOT CROSS PIPE E.S.#2 INV. 13.0 W/ 10'X15'X18" ED SPEED LIMIT 35 MPH SP E E D L I M I T 4 5 M P H MONITORING WELL (TYP) STAIR STAIR PR O P . 2 - S T O R Y B U I L D I N G FF E : 1 9 . 0 7' UP 18.95 9' UP 18.81 18.81 18.81 18.81 18.81 18.95 18.95 18.15 8' 5' C O N C R E T E F O R H V A C / M E C H . 18.95 18.95 18.95 18.75 18" FES#3 INV. 13.4 W/ 5'X10'X12" ED 30" NCDOT CROSS PIPE E.S. #1 INV: 13.2 18.0 17.9 17.55 18.81 18.75 18.75 18.25 18.25 18.75 18.25 18.95 17.75 18.85 6" A D S N 1 2 CP P @ 0 . 0 % 6" PVC @ 0.0% 16 PERMEABLE PAVEMENT AREA#1 18.75 PERMEABLE PAVEMENT AREA#3 PERMEABLE PAVEMENT AREA#2 18.75 17.25 17.8 18" FES#1 INV. 15.8 18.25 18.25 18.25 18.5 18.5 18.45 6" SDCO (TYP) 18.75 18.25 18.75 3' CURB CUT (TYP X 8) 18.5 BOC. 19.0 18.4 18.2 6" A D S N 1 2 C P P @ 0 . 0 % 18.95 18.2 17.5 C-1 2 1" = 30' SITE DATA PARCEL ID:R01109-001-001-000 CURRENT ZONING:B-2 PROJECT ADDRESS:5901 CASTLE HAYNE RD. CASTLE HAYNE, NC 28429 CURRENT OWNER:REAGAN LLC 303 FOX LAKE DR. CLINTON, NC 28328 TOTAL ACREAGE IN PROJECT BOUNDARY 75,707 S.F. (± 1.74 ac.) PROPOSED USE:RETAIL (Part of 1st Floor) & GENERAL OFFICE (Part of 1st and 2nd Floor) BUILDING SIZE:25,737 S.F. GFA TOTAL (13,200 S.F. FOOTPRINT) 12,537 S.F. 1st Floor (3,240 sf Office & 9,297 sf Retail) 13,200 S.F. 2nd Floor (Office) BUILDING HEIGHT:2-STORY/ ±28' CALCULATION FOR BUILDING COVERAGE: PROPOSED COVERAGE 13,200 S.F. ÷ 75,707 S.F. = 17.4% BUILDING SETBACKS: FRONT:REQUIRED= 25'PROPOSED= 79' SIDE:REQUIRED= 0' Interior/25' Street PROPOSED= 67' / 26' REAR:REQUIRED= 35' To Res. Use PROPOSED= 36' PROPOSED IMPERVIOUS AREAS: BUILDINGS 13,200 S.F. CONCRETE DRIVE AREA 4,715 S.F. CONCRETE SIDEWALK, C.&G., ETC. 7,130 S.F. TOTAL 25,045 S.F (33.1%) PROPOSED PERVIOUS AREAS: PERVIOUS CONCRETE DRIVE AREA 11,195 S.F. ECORASTER BLOXX PARKING AREA 9,890 S.F. TOTAL 21,085 S.F PARKING REQUIRED: RETAIL SALES USE: (2.5/1,000 sf ) 9,297 SF/1000*2.5 = 23 SPACES GENERAL OFFICE USE: (2.5/1,000 sf ) 16,440 SF/1000*2.5 = 41 SPACES TOTAL PARKING REQUIRED:64 SPACES (3 ADA) PARKING PROVIDED:66 SPACES (3 ADA) PARKING LOT INTERIOR LANDSCAPING REQUIRED 25,825 S.F. * 8% 2,066 S.F. PROVIDED 2,740 S.F. FOUNDATION PLANTINGS: NORTH FACADE: 60 LF X 12' FACADE X 12% REQUIRED:87 S.F. PROVIDED:240 S.F. EAST FACADE: 220 LF X 12' FACADE X 12% REQUIRED:317 S.F. PROVIDED:520 S.F. STREETYARD CASTLE HAYNE RD.: (25 S.F./LF FRONTAGE. 12.5' MIN./37.5' MAX. WIDTHS) 330 LF FRONTAGE 330- 25 LF DRIVEWAY = 305 LF FRONTAGE REQUIRED: 25' X 305 LF 7,625 S.F. PROVIDED:7,758 S.F. STREETYARD LYNN AVE.: (12.5 S.F./LF FRONTAGE. 6.25' MIN./18.75' MAX. WIDTHS) 175 LF FRONTAGE 175- 19 LF DRIVEWAY = 156 LF FRONTAGE REQUIRED: 12.5' X 156 LF 1,950 S.F. PROVIDED:2,030 S.F. EXISTING SEWER AND WATER DEMAND: 0 GPD PROPOSED SEWER AND WATER DEMAND:2,420 GPD ESTIMATED TRIP GENERATION (Per Trip Generation Manual): 9,297 SF RETAIL SHOPPING CENTER (ITE CODE 822) AM PEAK: 22 PM PEAK: 61 DAILY: 506 16,440 SF GENERAL OFFICE (ITE CODE 710) AM PEAK: 36 PM PEAK: 38 DAILY: 243 PROJECT TOTAL:AM PEAK: 58 PM PEAK: 99 DAILY: 750 EN G I N E E R I N G , P L L C IN T R A C O A S T A L REVISIONS Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 57 2 5 O l e a n d e r D r . U n i t E - 7 Ph o n e : 9 1 0 . 8 5 9 . 8 9 8 3 PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): Em a i l : C h a r l i e @ i n t r a c o a s t a l e n g i n e e r i n g . c o m 2024-007 FO R CLIENT INFORMATION: Reagan, LLC 303 Fox Lake Dr. Clinton, NC 28328 OF 10 JAE CDC CDC 24x36 10/23/2025 Li c e n s e N u m b e r : P - 0 6 6 2 NE W H A N O V E R C O U N T Y , N C RE A G A N R E T A I L A N D OF F I C E C E N T E R SITE CA S T L E H A Y N E R D CASTLE AVE. HOLLY SHELTER R D . PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N DEVELOPMENT NOTES: 1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY LAND DEVELOPMENT CODE. 2.PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS. 3.NO SIGNS ARE PROPOSED AT THIS TIME. ANY FUTURE PROPOSED SIGN IS SUBJECT TO SECTION 5.6. OF THE UDO. 4.RUNOFF FROM ALL IMPERVIOUS SURFACES TO BE DIRECTED TO PROPOSED PERMEABLE PAVEMENT/PAVER SYSTEM. SCREENED ROOF DRAINS SHOULD BE PIPED DIRECTLY INTO THE STONE BASE OF THE PERMEABLE PAVEMENT LOCATED AT THE FRONT AND/OR REAR OF THE PROPOSED BUILDING. FIRE & SAFETY NOTES: 1.CONSTRUCTION TYPE: II-B (COMMERCIAL) 2.PROPOSED BUILDING TO BE SPRINKLED. 3.CONTRACTOR SHALL MAINTAIN AN ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES DURING CONSTRUCTION. 4.BUILDING INFORMATION SIGNS MUST BE PROVIDED IN ACCORDANCE WITH THE "2018 NC FIRE CODE APPENDIX J" REQUIREMENTS. 5.CONTRACTOR SHALL SUBMIT A RADIO SIGNAL STRENGTH STUDY FOR ALL COMMERCIAL BUILDINGS THAT DEMONSTRATES THAT EXISTING EMERGENCY RESPONDER RADIO SIGNAL LEVELS MEET THE REQUIREMENTS OF SECTION 510 OF THE 2018 NC FIRE CODE. 6.ANY DRIVEWAY GATE TO BE SIREN ACTIVATED AND HAVE KNOX KEY OVERRIDE. 7.ALL FIRE HYDRANTS MUST BE INSTALLED WITH 5 INCH STORZ QUICK CONNECTS ON A 4.5 INCH STEAMER IN COMPLIANCE WITH NHC FIRE SERVICE REQUIREMENTS. 8.NO OBSTRUCTIONS WITHIN 36" AROUND A FIRE HYDRANT, INCLUDING BUT NOT LIMITED TO, STREET SIGNS, LANDSCAPING AND UTILITY POLES AND BOXES. 9.NEW HYDRANTS MUST BE BROUGHT INTO SERVICE PRIOR TO COMBUSTIBLE MATERIALS DELIVERED TO THE JOB SITE. 10.FIRE APPARATUS ACCESS ROADS SHALL PROVIDE A CLEAR VERTICAL CLEARANCE OF 14 FEET INCLUDING TREES, CANOPIES, BRIDGES, ETC. 11.DURING CONSTRUCTION, PREMISES IDENTIFICATION IS REQUIRED, AND MAY BE TEMPORARY IN NATURE PROVIDED IT IS LEGIBLE AND WEATHER RESISTANT. 12.PREMISES IDENTIFICATION IS REQUIRED. ADDRESS NUMBERS ARE REQUIRED ON THE STREET SIDE. NUMBERS SHALL NOT BE LESS THAN 6 INCHES TALL AND ¾ INCHES WIDE, MUST BE WEATHER RESISTANT, AND CONTRAST IN COLOR AGAINST THEIR BACKGROUND. PROPERTY LINE RIGHT OF WAY EXISTING EDGE OF PAVEMENT EASEMENT PROPOSED WATERLINE PROPOSED FIRE LINE PROPOSED SANITARY SEWER LINE RUNOFF DIRECTION SPOT ELEVATION PARKING LOT LANDSCAPING STREETYARD LANDSCAPING FOUNDATION PLANTINGS PROPOSED PERMEABLE CONCRETE PROPOSED PERMEABLE PAVERS LEGEND 25.5 SI T E , G R A D I N G , D R A I N A G E , & ST O R M W A T E R P L A N 60'30'15'30'0' Scale: 1"=30' UTILITY NOTES: 1.EXISTING WATER AND SANITARY SEWER SERVICES ARE CURRENTLY AVAILABLE TO THE SITE FROM CAPE FEAR PUBLIC UTILITY AUTHORITY PUBLIC MAINS. 2.ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS & TELEPHONE SHALL BE INSTALLED UNDERGROUND. 3.ALL WATER & SEWER UTILITIES TO BE INSTALLED PER CFPUA TECHNICAL SPECIFICATIONS & STANDARDS. 4.PROJECT SHALL COMPLY WITH CFPUA CROSS CONNECTION CONTROL REQUIREMENTS. WATER METER(S) CANNOT BE RELEASED UNTIL ALL REQUIREMENTS ARE MET AND N.C.D.E.N.R. HAS ISSUED THEIR "FINAL APPROVAL.". CALL 332-6558 FOR INFORMATION. 5.ANY BACKFLOW PREVENTION DEVICES REQUIRED BY THE CFPUA WILL NEED TO BE ON THE LIST OF APPROVED DEVICES BY USCFCCCHR OR ASSE. 6.IF CONTRACTOR DESIRES CFPUA WATER FOR CONSTRUCTION, HE SHALL APPLY IN ADVANCE FOR THIS SERVICE AND MUST PROVIDE A REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTION DEVICE ON THE DEVELOPER'S SIDE OF THE WATER METER BOX. 7.WHEN PVC WATER MAINS AND SERVICES ARE PROPOSED, THE PIPES ARE TO BE MARKED WITH NO. 10 INSULATED, SINGLE-STRAND COPPER WIRE INSTALLED & STRAPPED TO THE PIPES WITH DUCT TAPE. THIS IS TO BE ACCESSIBLE IN ALL VALVES AND METER BOXES TO AID IN FUTURE LOCATION OF FACILITIES. 8.SEWER GUARDS REQUIRED AT ALL MANHOLES. STAINLESS STEEL SEWER GUARDS REQUIRED AT MANHOLES LOCATED IN TRAFFIC AREAS. 9.SERVICES SHALL BE PERPENDICULAR TO MAIN AND TERMINATE AT RIGHT-OF-WAY LINE. SERVICES IN CUL-DE-SACS ARE REQUIRED TO BE PERPENDICULAR OR MUST ORIGINATE IN MANHOLE AND TERMINATE AT RIGHT-OF-WAY LINE. 10. ALL SERVICES TYING INTO DUCTILE IRON MAINS SHALL BE CONSTRUCTED OF CLASS 50 D.I.P. WITH PROTECTO 401 CERAMIC EPOXY LINING. 11.MINIMUM 10' UTILITIES EASEMENT PROVIDED ALONG THE FRONTAGE OF ALL LOTS AND AS SHOWN FOR NEW DEVELOPMENTS. 12.NO FLEXIBLE COUPLINGS SHALL BE USED. 13.ALL STAINLESS STEEL FASTENERS SHALL BE 316. 14.THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIES DURING CONSTRUCTION. CALL NC811 AT 811 OR 1-800-632-4949. CONTRACTOR IS RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ANY UTILITIES, CURB & GUTTER, PAVEMENT, ETC. THAT MAY BE BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIRED TO AT LEAST THE QUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM. 15.THE PROCESS FOR TELEPHONE CABLE PLACEMENT: * FINAL GRADE WILL NEED TO BE ESTABLISHED. * POWER WILL PLACE THEIR CABLE FIRST - APPROXIMATELY 3' DEEP. * BELLSOUTH & CABLE TV WILL THEN PLACE THEIR CABLE AT APPROXIMATELY 2' DEEP. 16.3' SEPARATION BETWEEN JOINTS, FITTINGS, SERVICE SADDLES AND WYES ARE REQUIRED FOR SS AND WATER TAPS. 17.ANY EXISTING SEWER AND WATER SERVICES NOT BEING UTILIZED ARE TO BE ABANDONED TO THE MAIN PER CFPUA STANDARDS. 18.SOLID WASTE DISPOSAL IS BY PRIVATE DUMPSTER SERVICE. LYNN AVENUE 50' PUBLIC RIGHT-OF-WAY T CASTLE AVENUE T FH T T TV MHOHW OHW OHW STREET LIGHT UTILITY MH WV WV GR A V . D / W GR A V . D / W GR A V . D / W GRAV. D/W GRAV. D/W CONC. D/W 36"CMP 36"CMP INV.12.68' INV.12.79' INV.13.71' INV.13.92' <= 1 8 " R C P INV.14.17' GRATE=16.35' <= 1 8 " R C P DI INV.OUT=14.35'(S) INV.IN=14.40(N) GRATE=16.34' DI INV.OUT=13.50'(S) INV.IN=13.35(N) 8"PVC W/L PER CFPUA 8" P V C W / L PE R C F P U A X X X X X X X X X X X XXXXXXXX 16 P I N E 12 O A K 6 M A G N O L I A 19 PINE 17 O A K 15 OAK 8 OAK 21 OAK 11 OAK 26 PINE 18 OAK 12 OAK 36 OAK 7' S I D E W A L K MH 25' 25 ' P U B L I C U T I L I T Y E A S E M E N T DB . 4 3 1 8 / P G . 0 3 1 3 UP 5' SIDEWALK 24 PECAN INV.15.66' INV.15.60' 24 " R C P <= 1 5 " R C P 24" RCP INV.=13.45' INV.IN=15.35' <= 1 8 " R C P SE W E R L I N E = > INV.OUT=14.67' (N) INV.IN=14.74' (S) RIM=17.52' SSMH D/W GRAV. D/W CONC. T T T CA S T L E H A Y N E R O A D 10 0 ' P U B L I C R I G H T - O F - W A Y N. C . H W Y 1 3 3 n/f CIRCLE K STORES INC BK 6634, PG 1085 Zoning: B-2 Use: VACANT n/f JEFFREY SUTTON HEIRS ETAL BK 9908, PG 0318 Zoning: B-2 Use: COMMERCIAL n/f TONI L SUTTON BK 5240, PG 0048 Zoning: B-2 Use: COMMERCIAL n/f MCCLURE MEMORIAL PRESBYTERIAN BK 1708, PG 0544 Zoning: B-2 Use: CHURCH n/f NEFTALI BALDERAMA GARCIA BK 6283, PG 2899 Zoning: RA Use: Single Family Residence n/f HILLSBOROUGH STREET LLC BK 6472, PG 1344 Zoning: B-2 Use: COMMERCIAL n/f CAROLINE L. BORDEAUX BK 3665, PG 0818 Zoning: RA Use: Single Family Residence n/f SIMON P PARKIN BK 1536, PG 2092 Zoning: B-2 Use: Single Family Residence 13 14 14 14 14 14 14 14 16 16 16 16 16 16 16 1 6 1 6 1 6 16 16 17 17 17 17 17 17 17 17 17 17 1 7 17 17 17 17 17 17 17 1 8 1 8 18 18 1 8 18 1 8 18 18 18 19 19 19 1 9 21 2 1 21 2 1 22 22 2 2 15 15 15 15 15 1 5 15 15 15 15 15 20 20 2 0 6" SSCO (TYP) TIE TO EX. SSMH (1) TIE TO EX. WATER MAIN W/ 8" CUT-IN TEE (1) 8" G.V. (EX. WATER MAIN ±3' DEEP) 3' SEPARATION BETWEEN JOINTS, FITTINGS, SERVICE SADDLES AND WYES ARE REQUIRED FOR SS AND WATER TAPS. (1) 8"X2" T.S.&V. (1) 2" WATER SERVICE W/ 1.0" METER 18" INSIDE EASEMENT & CFPUA APPROVED BACKFLOW PREVENTOR INV.12.84' INV.12.85' (1) 8"X6" TEE (1) 6" DELINEATION VALVE LOCATED 18" INSIDE R/W (1) 6" C-900 PVC PRIVATE FIRE LINE (1) 6" WATTS MODEL# LF957 RPDA NO EASEMENT LISTED GENERAL UTILITY EASEMENT WIDTH (2) 45° BENDS 2" WATER SERVICE (36" MIN. BURY) 8" FIRE SERVICE (36" MIN. BURY) (1) F.H. ASSY F.D.C. LOCATED ON CORNER OF BUILDING 1 0 ' 8" C-900 PVC PUBLIC WATER MAIN (36" MIN. BURY) EXISTING BUILDING CONDUIT TO BE RUN FOR FUTURE EV CHARING STATIONS 1 8 PROP. 10' PUBLIC D.E. & U.E. 6" S S S E R V I C E @ 1 . 0 % M I N . SPEED LIMIT 35 MPH SP E E D L I M I T 4 5 M P H (1) 10' X 15' X 4' BORE PIT 10' X 10' X 4' RECEIVING PIT 6.3'10 ' 10' 10 ' ±60 L.F. JACK & BORE BORE (8" C-900 PVC CARRIER PIPE IN 12" X 0.25" WALL STEEL CASING PIPE @ 3' MIN. COVER) 5.3'13.4' 8'15' 8" C - 9 0 0 P V C P U B L I C W A T E R M A I N ( 3 6 " M I N . B U R Y ) 5' (1) 2"B.O. ASSY (SEE DETAIL) (1) 2"B.O. ASSY (SEE DETAIL) (1) 8" TEE (2) 8" G.V. STAIR STAIR PR O P . 2 - S T O R Y B U I L D I N G FF E : 1 9 . 0 7' UP UP 5' C O N C R E T E F O R H V A C / M E C H . C-2 3 1" = 30' SITE DATA PARCEL ID:R01109-001-001-000 CURRENT ZONING:B-2 PROJECT ADDRESS:5901 CASTLE HAYNE RD. CASTLE HAYNE, NC 28429 CURRENT OWNER:REAGAN LLC 303 FOX LAKE DR. CLINTON, NC 28328 TOTAL ACREAGE IN PROJECT BOUNDARY 75,707 S.F. (± 1.74 ac.) PROPOSED USE:RETAIL (1st Floor) & GENERAL OFFICE (2nd Floor) BUILDING SIZE:26,400 S.F. GFA TOTAL (13,200 S.F. FOOTPRINT) BUILDING HEIGHT:2-STORY/ ±28' EXISTING SEWER AND WATER DEMAND: 0 GPD PROPOSED SEWER AND WATER DEMAND:2,420 GPD EN G I N E E R I N G , P L L C IN T R A C O A S T A L REVISIONS Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 57 2 5 O l e a n d e r D r . U n i t E - 7 Ph o n e : 9 1 0 . 8 5 9 . 8 9 8 3 PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): Em a i l : C h a r l i e @ i n t r a c o a s t a l e n g i n e e r i n g . c o m 2024-007 FO R CLIENT INFORMATION: Reagan, LLC 303 Fox Lake Dr. Clinton, NC 28328 OF 10 JAE CDC CDC 24x36 10/23/2025 Li c e n s e N u m b e r : P - 0 6 6 2 NE W H A N O V E R C O U N T Y , N C RE A G A N R E T A I L A N D OF F I C E C E N T E R SITE CA S T L E H A Y N E R D CASTLE AVE. HOLLY SHELTER R D . PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N DEVELOPMENT NOTES: 1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY LAND DEVELOPMENT CODE. 2.PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS. 3.NO SIGNS ARE PROPOSED AT THIS TIME. ANY FUTURE PROPOSED SIGN IS SUBJECT TO SECTION 5.6. OF THE UDO. 4.RUNOFF FROM ALL IMPERVIOUS SURFACES, INCLUDING ROOF DRAINS, TO BE DIRECTED TO PROPOSED UNDERGROUND INFILTRATION SYSTEM. FIRE & SAFETY NOTES: 1.CONSTRUCTION TYPE: II-B (COMMERCIAL) 2.PROPOSED BUILDING TO BE SPRINKLED. 3.CONTRACTOR SHALL MAINTAIN AN ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES DURING CONSTRUCTION. 4.BUILDING INFORMATION SIGNS MUST BE PROVIDED IN ACCORDANCE WITH THE "2018 NC FIRE CODE APPENDIX J" REQUIREMENTS. 5.CONTRACTOR SHALL SUBMIT A RADIO SIGNAL STRENGTH STUDY FOR ALL COMMERCIAL BUILDINGS THAT DEMONSTRATES THAT EXISTING EMERGENCY RESPONDER RADIO SIGNAL LEVELS MEET THE REQUIREMENTS OF SECTION 510 OF THE 2018 NC FIRE CODE. 6.ANY DRIVEWAY GATE TO BE SIREN ACTIVATED AND HAVE KNOX KEY OVERRIDE. 7.ALL FIRE HYDRANTS MUST BE INSTALLED WITH 5 INCH STORZ QUICK CONNECTS ON A 4.5 INCH STEAMER IN COMPLIANCE WITH NHC FIRE SERVICE REQUIREMENTS. 8.NO OBSTRUCTIONS WITHIN 36" AROUND A FIRE HYDRANT, INCLUDING BUT NOT LIMITED TO, STREET SIGNS, LANDSCAPING AND UTILITY POLES AND BOXES. 9.NEW HYDRANTS MUST BE BROUGHT INTO SERVICE PRIOR TO COMBUSTIBLE MATERIALS DELIVERED TO THE JOB SITE. 10.FIRE APPARATUS ACCESS ROADS SHALL PROVIDE A CLEAR VERTICAL CLEARANCE OF 14 FEET INCLUDING TREES, CANOPIES, BRIDGES, ETC. 11.DURING CONSTRUCTION, PREMISES IDENTIFICATION IS REQUIRED, AND MAY BE TEMPORARY IN NATURE PROVIDED IT IS LEGIBLE AND WEATHER RESISTANT. 12.PREMISES IDENTIFICATION IS REQUIRED. ADDRESS NUMBERS ARE REQUIRED ON THE STREET SIDE. NUMBERS SHALL NOT BE LESS THAN 6 INCHES TALL AND ¾ INCHES WIDE, MUST BE WEATHER RESISTANT, AND CONTRAST IN COLOR AGAINST THEIR BACKGROUND. PROPERTY LINE RIGHT OF WAY EXISTING EDGE OF PAVEMENT EASEMENT PROPOSED WATERLINE PROPOSED FIRE LINE PROPOSED SANITARY SEWER LINE LEGEND UT I L I T I E S P L A N 60'30'15'30'0' Scale: 1"=30' UTILITY NOTES: 1.EXISTING WATER AND SANITARY SEWER SERVICES ARE CURRENTLY AVAILABLE TO THE SITE FROM CAPE FEAR PUBLIC UTILITY AUTHORITY PUBLIC MAINS. 2.ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS & TELEPHONE SHALL BE INSTALLED UNDERGROUND. 3.ALL WATER & SEWER UTILITIES TO BE INSTALLED PER CFPUA TECHNICAL SPECIFICATIONS & STANDARDS. 4.PROJECT SHALL COMPLY WITH CFPUA CROSS CONNECTION CONTROL REQUIREMENTS. WATER METER(S) CANNOT BE RELEASED UNTIL ALL REQUIREMENTS ARE MET AND N.C.D.E.N.R. HAS ISSUED THEIR "FINAL APPROVAL.". CALL 332-6558 FOR INFORMATION. 5.ANY BACKFLOW PREVENTION DEVICES REQUIRED BY THE CFPUA WILL NEED TO BE ON THE LIST OF APPROVED DEVICES BY USCFCCCHR OR ASSE. 6.IF CONTRACTOR DESIRES CFPUA WATER FOR CONSTRUCTION, HE SHALL APPLY IN ADVANCE FOR THIS SERVICE AND MUST PROVIDE A REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTION DEVICE ON THE DEVELOPER'S SIDE OF THE WATER METER BOX. 7.WHEN PVC WATER MAINS AND SERVICES ARE PROPOSED, THE PIPES ARE TO BE MARKED WITH NO. 10 INSULATED, SINGLE-STRAND COPPER WIRE INSTALLED & STRAPPED TO THE PIPES WITH DUCT TAPE. THIS IS TO BE ACCESSIBLE IN ALL VALVES AND METER BOXES TO AID IN FUTURE LOCATION OF FACILITIES. 8.SEWER GUARDS REQUIRED AT ALL MANHOLES. STAINLESS STEEL SEWER GUARDS REQUIRED AT MANHOLES LOCATED IN TRAFFIC AREAS. 9.SERVICES SHALL BE PERPENDICULAR TO MAIN AND TERMINATE AT RIGHT-OF-WAY LINE. SERVICES IN CUL-DE-SACS ARE REQUIRED TO BE PERPENDICULAR OR MUST ORIGINATE IN MANHOLE AND TERMINATE AT RIGHT-OF-WAY LINE. 10. ALL SERVICES TYING INTO DUCTILE IRON MAINS SHALL BE CONSTRUCTED OF CLASS 50 D.I.P. WITH PROTECTO 401 CERAMIC EPOXY LINING. 11.MINIMUM 10' UTILITIES EASEMENT PROVIDED ALONG THE FRONTAGE OF ALL LOTS AND AS SHOWN FOR NEW DEVELOPMENTS. 12.NO FLEXIBLE COUPLINGS SHALL BE USED. 13.ALL STAINLESS STEEL FASTENERS SHALL BE 316. 14.THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIES DURING CONSTRUCTION. CALL NC811 AT 811 OR 1-800-632-4949. CONTRACTOR IS RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ANY UTILITIES, CURB & GUTTER, PAVEMENT, ETC. THAT MAY BE BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIRED TO AT LEAST THE QUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM. 15.THE PROCESS FOR TELEPHONE CABLE PLACEMENT: * FINAL GRADE WILL NEED TO BE ESTABLISHED. * POWER WILL PLACE THEIR CABLE FIRST - APPROXIMATELY 3' DEEP. * BELLSOUTH & CABLE TV WILL THEN PLACE THEIR CABLE AT APPROXIMATELY 2' DEEP. 16.3' SEPARATION BETWEEN JOINTS, FITTINGS, SERVICE SADDLES AND WYES ARE REQUIRED FOR SS AND WATER TAPS. 17.ANY EXISTING SEWER AND WATER SERVICES NOT BEING UTILIZED ARE TO BE ABANDONED TO THE MAIN PER CFPUA STANDARDS. 18.SOLID WASTE DISPOSAL IS BY PRIVATE DUMPSTER SERVICE. LYNN AVENUE 50' PUBLIC RIGHT-OF-WAY T CASTLE AVENUE T FH TT TV MHOHW OHW OHW STREET LIGHT UTILITY MH WV WV GR A V . D / W GR A V . D / W GRAV. D/W GRAV. D/W CONC. D/W 36"CMP 36"CMP INV.12.68' INV.12.79' INV.13.71' INV.13.92' <= 1 8 " R C P INV.14.17' GRATE=16.35' <= 1 8 " R C P DI INV.OUT=14.35'(S) INV.IN=14.40(N) 8"PVC W/L PER CFPUA 8" P V C W / L PE R C F P U A X X X X X X X X X X X XXXXXXXX 16 P I N E 12 O A K 6 M A G N O L I A 19 PINE 17 O A K 15 OAK 8 OAK 21 OAK 11 OAK 26 PINE 18 OAK 12 OAK 36 OAK 7' S I D E W A L K MH 25' 25 ' P U B L I C U T I L I T Y E A S E M E N T DB . 4 3 1 8 / P G . 0 3 1 3 UP 5' SIDEWALK 24 PECAN INV.15.66' INV.15.60' 24 " R C P <= 1 5 " R C P 24" RCP INV.=13.45' INV.IN=15.35' <= 1 8 " R C P SE W E R L I N E = > INV.OUT=14.67' (N) INV.IN=14.74' (S) RIM=17.52' SSMH D/W GRAV. D/W CONC. TT T CA S T L E H A Y N E R O A D 10 0 ' P U B L I C R I G H T - O F - W A Y N. C . H W Y 1 3 3 13 14 14 14 14 14 14 14 16 16 16 16 16 16 16 1 6 1 6 1 6 16 16 17 17 17 17 17 17 17 17 17 17 1 7 17 17 17 17 17 18 1 8 1 8 1 8 18 1 8 18 1 8 18 18 19 19 1 9 19 21 21 2 1 22 22 2 2 15 15 15 15 15 15 15 15 15 15 15 20 20 2 0 INV.12.84' INV.12.85' NO EASEMENT LISTED GENERAL UTILITY EASEMENT WIDTH 10' EXISTING BUILDING MATCH EX. ASPHALT ±17.517.2 17.05 17.25 17.8 DI# 1 RIM: 17.65 INV: 16.5 18.0 18.95 18.95 18.95 18.5 20.0 18.5 17.8 17.6 MATCH EX. ASPHALT ±18.25 SDMH#1 RIM: 16.8 INV: 15.5 17.45 18" FES#2 INV. 15.3 W/ 5'X10'X12" ED 18" RCP 18 " R C P 19 18 17 171819 15" R C P 18.1 1 8 18 21 20 20.5 20.020 NCDOT DI# 1 RIM: 18.5 INV: 15.5 PROP. 10' PUBLIC D.E. & U.E.15" RCP 18" RCP NCDOT CI# 1 RIM: 17.5 INV: 14.5 NCDOT CI# 2 RIM: 17.5 INV: 14.3 18 NCDOT SDMH#1 RIM: 16.8 INV: 13.6 18" R C P TEMPORARY CONSTRUCTION ENTRANCE TEMPORARY CONSTRUCTION ENTRANCE 17.05 30 " R C P 30" NCDOT CROSS PIPE E.S.#2 INV. 13.0 W/ 10'X15'X18" ED SPEED LIMIT 35 MPH SP E E D L I M I T 4 5 M P H MONITORING WELL (TYP) STAIR STAIR PR O P . 2 - S T O R Y B U I L D I N G FF E : 1 9 . 0 7' UP 18.95 UP 18.81 18.81 18.81 18.81 18.81 18.95 18.95 18.15 5' C O N C R E T E F O R H V A C / M E C H . 18.95 18.95 18.95 18.75 18" FES#3 INV. 13.4 W/ 5'X10'X12" ED 30" NCDOT CROSS PIPE E.S. #1 INV: 13.2 18.0 17.9 17.55 18.81 18.75 18.75 18.25 18.25 18.75 18.25 18.95 17.75 18.85 6" A D S N 1 2 CP P @ 0 . 0 % 6" PVC @ 0.0% 16 PERMEABLE PAVEMENT AREA#1 18.75 PERMEABLE PAVEMENT AREA#3 PERMEABLE PAVEMENT AREA#2 18.75 17.25 17.8 18" FES#1 INV. 15.8 18.25 18.25 18.25 18.5 18.5 18.45 6" SDCO (TYP) 18.75 18.25 18.75 3' CURB CUT (TYP X 8) 18.5 BOC. 19.0 18.4 18.2 6" A D S N 1 2 C P P @ 0 . 0 % 18.95 18.2 17.5 C-3 4 1" = 30' SITE DATA PARCEL ID:R01109-001-001-000 CURRENT ZONING:B-2 PROJECT ADDRESS:5901 CASTLE HAYNE RD. CASTLE HAYNE, NC 28429 CURRENT OWNER:REAGAN LLC 303 FOX LAKE DR. CLINTON, NC 28328 TOTAL ACREAGE IN PROJECT BOUNDARY 75,707 S.F. (± 1.74 ac.) TOTAL DISTURBED AREA 1.9 ac. EN G I N E E R I N G , P L L C IN T R A C O A S T A L REVISIONS Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 57 2 5 O l e a n d e r D r . U n i t E - 7 Ph o n e : 9 1 0 . 8 5 9 . 8 9 8 3 PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): Em a i l : C h a r l i e @ i n t r a c o a s t a l e n g i n e e r i n g . c o m 2024-007 FO R CLIENT INFORMATION: Reagan, LLC 303 Fox Lake Dr. Clinton, NC 28328 OF 10 JAE CDC CDC 24x36 10/23/2025 Li c e n s e N u m b e r : P - 0 6 6 2 NE W H A N O V E R C O U N T Y , N C RE A G A N R E T A I L A N D OF F I C E C E N T E R SITE CA S T L E H A Y N E R D CASTLE AVE. HOLLY SHELTER R D . PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N SE D I M E N T A T I O N & E R O S I O N CO N T R O L P L A N PROPERTY LINE ADJOINERS RUNOFF DIRECTION WATERLINE SANITARY SEWER LINE SILT FENCE LIMITS OF DISTURBANCE SPOT ELEVATION CURB INLET W/ INLET PROTECTION DROP INLET W/ INLET PROTECTION LEGEND 25.5 * Perimeter dikes, ditches and slopes GROUND STABILIZATION CRITERIA 7 Days SITE AREA DESCRIPTION STABILIZATION TIMEFRAME STABILIZATION TIMEFRAME EXCEPTIONS None 7 Days None * High Quality Water (HQW) Zones 7 Days If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed * Slopes Steeper than 3:1 14 Days* Slopes 3:1 or flatter 7-days for slopes greater than 50 ft. in length 14 Days* All other areas with slopes flatter than 4:1 None (except for perimeters & HQW Zones) SYMBOL BUILDING WASTE HANDLING: -NO PAINT OR LIQUID WASTES IN STREAM OR STORM DRAINS -DEDICATED AREAS FOR DEMOLITION, CONSTRUCTION AND OTHER WASTES MUST BE LOCATED 50' FROM STORM DRAINS AND STREAMS UNLESS NO REASONABLE ALTERNATIVES ARE AVAILABLE. -EARTHEN MATERIAL STOCKPILES MUST BE LOCATED 50' FROM STORM DRAINS AND STREAMS UNLESS NO REASONABLE ALTERNATIVES ARE AVAILABLE. -CONCRETE MATERIALS MUST BE CONTROLLED TO AVOID CONTACT WITH SURFACE WATERS, WETLANDS, OR BUFFERS. INSPECTIONS: -SAME WEEKLY REQUIREMENTS -SAME RAIN GAUGE & INSPECTIONS AFTER 0.50" RAIN EVENT. -INSPECTIONS ARE ONLY REQUIRED DURING "NORMAL BUSINESS HOURS" -INSPECTION REPORTS MUST BE AVAILABLE ON-SITE DURING BUSINESS HOURS UNLESS A SITE-SPECIFIC EXEMPTION IS APPROVED. -RECORDS MUST BE KEPT FOR 3 YEARS AND AVAILABLE UPON REQUEST. -ELECTRONICALLY AVAILABLE RECORDS MAY BE SUBSTITUTED UNDER CERTAIN CONDITIONS. SEDIMENT BASINS: -OUTLET STRUCTURES MUST BE WITHDRAWN FROM BASIN SURFACES UNLESS DRAINAGE AREA IS LESS THAN 1 ACRE. -USE ONLY DWQ APPROVED FLOCCULANTS. MAINTENANCE PLAN: 1.ALL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF-PRODUCING RAINFALL, BUT IN NO CASE, LESS THAN ONCE EVERY WEEK AND WITHIN 24 HOURS OF EVERY HALF INCH RAINFALL. 2.ALL POINTS OF EGRESS WILL HAVE CONSTRUCTION ENTRANCES THAT WILL BE PERIODICALLY TOP-DRESSED WITH AN ADDITIONAL 2 INCHES OF 2-3 INCH STONE TO MAINTAIN PROPER DEPTH. THEY WILL BE MAINTAINED IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE SITE. IMMEDIATELY REMOVE OBJECTIONABLE MATERIAL SPILLED, WASHED OR TRACKED ONTO THE CONSTRUCTION ENTRANCE OR ROADWAYS. 3.SEDIMENT WILL BE REMOVED FROM HARDWARE CLOTH AND GRAVEL INLET PROTECTION, ROCK DOUGHNUT INLET PROTECTION, SEDIMENT TRAP BAFFLES, AND ROCK PIPE INLET PROTECTION WHEN THE DESIGNED STORAGE CAPACITY HAS BEEN HALF FILLED WITH SEDIMENT. ROCK WILL BE CLEANED OR REPLACED WHEN THE SEDIMENT POOL NO LONGER DRAINS AS DESIGNED. DEBRIS WILL BE REMOVED FROM THE ROCK AND HARDWARE CLOTH TO ALLOW PROPER DRAINAGE. SILT SACKS WILL BE EMPTIED ONCE A WEEK AND AFTER EVERY RAIN EVENT. SEDIMENT WILL BE REMOVED FROM AROUND BEAVER DAMS, DANDY SACKS AND SOCKS ONCE A WEEK AND AFTER EVERY RAIN EVENT. 4.SEDIMENT WILL BE REMOVED FROM BEHIND THE SEDIMENT FENCE WHEN IT BECOMES HALF FILLED. THE SEDIMENT FENCE WILL BE REPAIRED AS NECESSARY TO MAINTAIN A BARRIER. STAKES MUST BE STEEL. STAKE SPACING WILL BE 6 FEET MAX. WITH THE USE OF EXTRA STRENGTH FABRIC, WITHOUT WIRE BACKING. STAKE SPACING WILL BE 8 FEET MAX WHEN STANDARD STRENGTH FABRIC AND WIRE BACKING ARE USED. IF ROCK FILTERS ARE DESIGNED AT LOW POINTS IN THE IN THE SEDIMENT FENCE THE ROCK WILL BE REPAIRED OR REPLACED IF IT BECOMES HALF FULL OF SEDIMENT, NO LONGER DRAINS AS DESIGNED OR IS DAMAGED. NORTH CAROLINA TEMPORARY GRASSING DETAIL SEEDING MIXTURE SPECIES APPLICATION RATE LATE WINTER & EARLY SPRING: Rye (grain)100 (lb/acre) Annual Iespedeza (Kobe in Piedmont and Coastal Plain, Korean in Mountains)50 (lb/acre) Omit annual Iespedeza when duration of temporary cover is not to extend beyond June SUMMER: German Millet In the Piedmont and Mountains,40 (lb/acre) a small-stemmed sundangrass may be substituted at a rate of 50 (lb/acre) FALL: Rye (grain)120 (lb/acre) SEEDING DATES LATE WINTER & EARLY SPRING: Mountains - Above 2500 ft: Feb. 15-May 15 Piedmont - Jan. 1-May 1 Coastal Plain - Dec. 1-Apr. 15 SUMMER: Mountains - May 15-Aug. 15 Piedmont - May 1-Aug. 15 Coastal Plain - Apr. 15-Aug. 15 FALL: Mountains - Aug. 15-Dec. 15 Coastal Plain and Piedmont - Aug. 15-Dec. 30 SOIL AMENDMENTS: Follow recommendations of soil tests or apply 2,000 lb/acre ground agricultural limestone and 750 lb/acre 10-10-10 fertilizer. MULCH: apply 4,000 lb/acre straw. anchor straw by tacking with asphalt, netting, or a mulch anchoring tool. A disk with blades set nearly straight can be used as a mulch anchoring tool. MAINTENANCE: Refertilize if growth is not fully adequate. reseed, refertilize and mulch immediately following erosion or other damage. NORTH CAROLINA PERMANENT GRASSING DETAIL SEEDING MIXTURE SPECIES APPLICATION RATE FALL & WINTER: Tall Fescue (blend of two or 200 (lb/acre) three improved varieties) Rye (grain) 25 (lb/acre) SPRING & SUMMER: Pensacola Bahiagrass 50 (lb/acre) Sericea Lespedeza 30 (lb/acre) Common Bermudagrass 10 (lb/acre) German Millet 10 (lb/acre) Tall Fescue 50 (lb/acre) SEEDING DATES FALL & WINTER: January - April August - December SOIL AMENDMENTS: Apply lime and fertilizer according to soil tests, or apply 3.000-5,000 lb/acre ground agricultural limestone (use the lower rate on sandy soils) and 1,000 lb/acre 10-10-10 fertilizer. MAINTENANCE: Fertilize according to soil tests or apply 40 lb/acre nitrogen in January or february, 40 lb in September and 40 lb in November, from a 12-4-8, 16-4-8, or similar turf fertilizer. Avoid fertilizer applications during warm weather, as this increases stand losses to disease. Reseed, fertilize, and mulch damaged areas immediately. mow to a height of 2.5-3.5 inches as needed. SPRING & SUMMER: April 1 - July 15 SOIL AMENDMENTS: Apply lime and fertilizer according to soil tests, or apply 3,000 lb/acre ground agriculture limestone and 500 lb/acre 10-10-10 fertilizer. MAINTENANCE: Refertilize the following april with 50 lb/acre nitrogen. Repeat as growth requires. may be mowed only once a year. Where a neat appearance is desired, omit sericea and mow as often as needed. MULCH: apply 4,000 lb/acre straw. anchor straw by tacking with asphalt, netting, or a mulch anchoring tool. A disk with blades set nearly straight can be used as a mulch anchoring tool. 60'30'15'30'0' Scale: 1"=30' CONSTRUCTION SEQUENCE: *PRIOR TO START OF CONSTRUCTION, A PRE-CONSTRUCTION MEETING WITH THE NHC EROSION CONTROL INSPECTOR MUST BE HELD.* CONSTRUCTION OF SITE TO START WITH INSTALLATION OF CONSTRUCTION ENTRANCE, SILT FENCE, AND SILT FENCE OUTLETS ALONG ALL LOCATIONS PER PLANS. TREES CAN NOW BE REMOVED IN LOCATIONS AS NECESSARY. SITE GRADING OF BUILDING PADS AND PARKING/ACCESS AREAS SHOULD FOLLOW. ALL SLOPED AREAS SHOULD BE SEEDED IN ACCORDANCE TO SPECIFICATIONS. SLOPE STABILIZATION IS WITHIN 21 CALENDAR DAYS OF ANY PHASE OF CONSTRUCTION. ALL OTHER AREAS MUST BE STABILIZED WITH IN 15 WORKING DAYS. CONTRACTOR TO FOLLOW NPDES STABILIZATION REQUIREMENTS PER TABLE ON THIS SHEET AS WELL. MOST STRINGENT REQUIREMENT TO BE MET. 1.GENERAL CLEARING AND GRADING OF THIS SITE WILL NOT BE DONE UNTIL THE TEMPORARY SILT FENCE & CONSTRUCTION ENTRANCE HAS BEEN INSTALLED. 2.NO CUT SLOPE OR FILL SLOPE SHALL EXCEED A RISE OR FALL OF ONE FOOT FOR EVERY RUN OF 3 FEET (1 VERTICAL TO 3 HORIZONTAL). 3.NO SEDIMENT WILL BE ALLOWED TO EXIT THE SITE. ALL EROSION SHALL BE CONTROLLED INCLUDING SIDE SLOPES DURING AND AFTER CONSTRUCTION. 4.INSTALL PRIMARY EROSION CONTROL MEASURES BEFORE BEGINNING CONSTRUCTION INCLUDING BUT NOT LIMITED TO GRAVELED CONSTRUCTION ENTRANCE, SILT FENCE, TREE PROTECTION FENCE & SEDIMENT BASINS. CONTRACTOR TO BE FAMILIAR WITH USACOE GENERAL PERMIT CONDITIONS FOR ROAD CROSSINGS. SPECIFIC CONSTRUCTION METHODS MAY BE REQUIRED ABOVE AND BEYOND WHAT IS SPECIFIED IN THIS PLAN. INSTALL ALL SECONDARY EROSION CONTROL MEASURES, SUCH AS INLET PROTECTION AS SOON AS POSSIBLE AFTER BEGINNING CONSTRUCTION. 5.ALL EROSION CONTROL MEASURES TO BE INSPECTED AFTER EACH RAIN. SILT FENCE AND INLET PROTECTION TO BE CLEANED WHEN HALF FULL. 6.ONCE PAVING IS COMPLETE, DANDY SACK INLET PROTECTION TO BE USED IF NEEDED, UNTIL SITE IS STABILIZED. 7.A 4" LAYER OF TOPSOIL SHALL BE APPLIED TO ALL NEW AREAS TO BE GRASSED. 8.MAINTAIN ALL EROSION CONTROL MEASURES UNTIL PROJECT IS COMPLETE. 9.MORE STRINGENT MEASURES MAY BE REQUIRED TO HALT EROSION IF THOSE ON THIS PLAN PROVE TO BE LESS EFFECTIVE. 10.REMOVE ALL TEMPORARY EROSION CONTROL MEASURES UPON COMPLETION OF CONSTRUCTION AND WITH APPROVAL FROM THE NHC EROSION CONTROL INSPECTOR. ALL PERMANENT MEASURES SHALL BE WELL ESTABLISHED PRIOR TO PROJECT COMPLETION. 11.PERMEABLE CONCRETE SUBGRADE MUST BE EITHER SCARIFIED, RIPPED, OR TRENCHED TO MAINTAIN THE PRE-CONSTRUCTION SUBGRADE INFILTRATION RATE. 12.GRADING FOR PERMEABLE PAVEMENT TO BE COMPLETED DURING DRY WEATHER. 13.AFTER INSTALLATION, PERMEABLE PAVEMENT SHALL BE PROTECTED FROM SEDIMENT DEPOSITION UNTIL THE SITE IS COMPLETED AND STABILIZED. AN IN-SITU INFILTRATION PERMEABILITY TEST SHALL BE CONDUCTED AND CERTIFIED ON THE PAVEMENT AFTER SITE STABILIZATION. 13.FIELD TESTING OF PERVIOUS CONCRETE SHALL BE DONE BY AN INDEPENDENT TESTING LABORATORY PAID FOR BY THE OWNER. FURTHER TESTING REQUIRED DUE TO A FAILED TEST WILL BE PAID FOR BY THE CONTRACTOR. C-4 5 DE T A I L S NTS EN G I N E E R I N G , P L L C IN T R A C O A S T A L REVISIONS Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 57 2 5 O l e a n d e r D r . U n i t E - 7 Ph o n e : 9 1 0 . 8 5 9 . 8 9 8 3 PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): Em a i l : C h a r l i e @ i n t r a c o a s t a l e n g i n e e r i n g . c o m 2024-007 FO R CLIENT INFORMATION: Reagan, LLC 303 Fox Lake Dr. Clinton, NC 28328 OF 10 JAE CDC CDC 24x36 10/23/2025 Li c e n s e N u m b e r : P - 0 6 6 2 NE W H A N O V E R C O U N T Y , N C RE A G A N R E T A I L A N D OF F I C E C E N T E R SITE CA S T L E H A Y N E R D CASTLE AVE. HOLLY SHELTER R D . PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N SITE WORK NOTES: 1.THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS BOTH ON AND ADJACENT TO THE SITE. 2.CLEARING: CONTRACTOR SHALL REMOVE ALL TREES AND VEGETATION WITHIN LIMITS OF CONSTRUCTION UNLESS OTHERWISE DESIGNATED TO REMAIN. 3.GRUBBING AND STRIPPING: CONTRACTOR SHALL RAKE AND REMOVE ROOTS, STUMPS, VEGETATION, DEBRIS, EXISTING STRUCTURES ABOVE AND BELOW GRADE, ORGANIC MATERIAL OR ANY OTHER UNSUITABLE MATERIAL WITHIN LIMITS OF CONSTRUCTION. 4.MUCKING: CONTRACTOR SHALL COORDINATE WITH OWNER AND THEIR GEOTECHNICAL REPRESENTATIVE TO COORDINATE REMOVAL OF ANY SOFT AREAS. 5.DISPOSAL: CLEARED, GRUBBED, STRIPPED OR OTHER WASTE MATERIAL SHALL BE REMOVED FROM SITE AND DISPOSED OF IN A PROPERLY PERMITTED FACILITY. 6.FILL AND COMPACTION SHOULD COMPLY WITH GEOTECHNICAL RECOMMENDATIONS. 7.THE CONTRACTOR SHALL NOTE THAT THE GRADING PLAN MAY NOT REPRESENT A BALANCED EARTHWORK CONDITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CUT AND FILL QUANTITIES AND COMPLETE INSTALLATION TO SPECIFIED GRADES. 8.THE CONTRACTOR SHALL FURNISH SUITABLE BORROW MATERIAL FROM AN OFF-SITE PROPERLY PERMITTED FACILITY AS REQUIRED. 9.INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXACT ELEVATIONS AND LOCATIONS OF ALL EXISTING UTILITIES AT ALL CROSSINGS PRIOR TO COMMENCING TRENCH EXCAVATION. IF ACTUAL CLEARANCES ARE LESS THAN INDICATED ON PLAN, THE CONTRACTOR SHALL CONTACT THE DESIGN ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. ANY CONDITION DISCOVERED OR EXISTING THAT WOULD NECESSITATE A MODIFICATION OF THESE PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. 10.NO CONSTRUCTION IS TO BEGIN BEFORE LOCATION OF EXISTING UTILITIES HAS BEEN DETERMINED. CALL "NC ONE-CALL" AT LEAST 48 HOURS BEFORE COMMENCING CONSTRUCTION. 11.THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES DURING CONSTRUCTION. BEFORE COMMENCING ANY EXCAVATIONS IN OR ALONG ROADWAYS OR RIGHT-OF-WAYS, PUBLIC AREAS OR IN PRIVATE EASEMENTS, THE CONTRACTOR SHALL NOTIFY ALL APPROPRIATE PERSONNEL OF THEIR INTENT TO EXCAVATE, IN WRITING, NOT LESS THAN 10 DAYS PRIOR TO EXCAVATING. 12.THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE DISCONNECTION/ RECONNECTION AND/OR THE RELOCATION OF ALL EXISTING UTILITIES WITH APPROPRIATE PERSONNEL. 13.CONTRACTOR SHALL ADJUST ALL MANHOLES, VALVE & CURB BOXES TO FINAL GRADE UPON COMPLETION OF ALL CONSTRUCTION. ANY BOXES DAMAGED OR OTHERWISE DISTURBED BY THE CONTRACTOR SHALL BE REPAIRED AT THE EXPENSE OF THE CONTRACTOR. 14.THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AT THE SITE. FURTHERMORE THE CONTRACTOR SHALL REPORT ALL DISCREPANCIES OR QUESTIONS TO THE ENGINEER PRIOR TO INSTALLATION. 15.THE CONTRACTOR SHALL PROVIDE ANY AND ALL LAYOUT REQUIRED TO CONSTRUCT HIS WORK UNLESS OTHERWISE DIRECTED BY OWNER. 16.ALL SERVICE CONNECTIONS SHALL BE INSTALLED TO MEET ALL LOCAL, STATE, AND CFPUA CODES. METERS, TAPS, MATERIALS, WORKMANSHIP AND ALL FEES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL COMPLY WITH ALL REQUIREMENTS. 17.ALL BACKFILL FROM UTILITY INSTALLATION MUST BE COMPACTED OR AMENDED TO PROVIDE TRAFFIC BEARING CAPACITY. GEOTECHNICAL ENGINEER TO BE CONSULTED AT CONTRACTORS COST AS NECESSARY. 18.ALL AREAS SHALL BE GRADED FOR POSITIVE DRAINAGE. CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO INSTALLATION. ALL AREAS SHALL BE SLOPED TO DRAIN AWAY FROM BUILDINGS AT ALL TIMES. 19.CONCRETE FOR WALKS, CURBS AND DRIVES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI @ 28 DAYS - AIR ENTRAINED. 20.FIELD TESTING SHALL BE DONE BY AN INDEPENDENT TESTING LABORATORY PAID FOR BY THE OWNER. FURTHER TESTING REQUIRED DUE TO A FAILED TEST WILL BE PAID FOR BY THE CONTRACTOR. 21.ALL SIDEWALKS SHALL BE FREE OF CRACKS, BREAKS, OR ANY OTHER DEFECT PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. 8" CONCRETE PAD W/CROSS-BRACING ENCLOSURE GATES 6X6 - 6/6 W.W.F. AT 3000 PSI W/ 2' 2' 10 ' WOOD SIDING HORIZONTAL (TREATED) 4"X4" POSTSFOOTINGS CONCRETE 8" 8' 2"X6" CAP PAVEMENT ASPHALT 10' 4"X4" POSTS DUMPSTER PAD & ENCLOSURE DETAIL ELEVATIONS PLAN NTS PROPOSED DRIVEWAY GRADE 2% MIN SLOPE 6' MIN FROM EX. EOP TYPICAL DRIVEWAY GRADING SECTION NTS EX. ROAD ±2% SLOPE CURB INLET DETAIL NTS VA R I E S 3000 PSI CONC. FLOW SECTION 6" 4" 8" PRE-CAST CONC. ASPHALT PAVEMENT ELEV. VARIES 8"6"D 8"6" GROUT IN S I D E W A L L BO C OR EQUALDEWEY BROS. MODEL CH-BN-2001FRAME AND GRATE2" SEE PLAN FOR PIPE ORIENTATION & SIZES NCDOT STD. NO.840.03 ORAPPROVED EQUAL OF B O X 1-1/2"R(TYP) WHITE SYMBOL ON BLUE BACKGROUND LEGEND AND BORDER - GREENBACKGROUND - WHITE 9" 12" 3/8"(TYP) LEGEND AND BORDER - GREEN BACKGROUND - WHITE 18 " 12" COLORS 1-1/2"R(TYP) LEGEND AND BORDER - GREENBACKGROUND - WHITE 9" 18" 3/8"(TYP) TO READ "VAN ACCESSIBLE". BOLT TO WD. POST WITH 3/8" CANDIUM PLATED NUTS, BOLTS & WASHERS 9" x 1'-6" x .080 STD ALUM. SIGN NUTS, BOLTS & WASHERS. 9" x 1'-0" x .080 STD ALUM. SIGN TO READ "MAXIMUM PENALTY $250, GS 20-37.6". BOLT TO WD. POST WITH 3/8" CANDIUM PLATED PRESSURE TREATED 4"x4" POST. 3' - 0 " M I N . FINISHEDGRADE 84 " HANDICAPPED PARKING SIGN WITH IDENTIFICATION SYMBOL. 1'-6" x 1'-0" x .080 STD. ALUM. TO READ "RESERVED PARKING" BOLT TO WD. POST W/ 3/8" CANDIUM PLATED NUTS, BOLTS & WASHERS. TYPICAL HANDICAPPED SIGN DETAIL NTS R7-8a Sign (no arrows) R7-8d Sign R7-8P Sign 8" V A R I E S PLAN 1" 6" 5 3/4" MANHOLE DIAMETERSHALL BE 1'-0"LARGER THAN THE FORM FLOW CHANNEL 3'-3" MIN. 3'-1 3/4" MIN. CONC.MH BLOCKS PRECAST MH RINGS SECTION STORM DRAIN MANHOLE DETAIL BLOCK CONC. M.H. NTS 8" P O U R E D B A S E 8"LARGEST PIPE 8" 1. CONTRACTOR MAY USE BRICK WITH MAX. CORBEL 1" PER COURSE 2. CONTRACTOR MAY USE ECCENTRIC M.H. UNIT 6" 8" 1 " MIN . 4' - 0 " NOTE MIN WEIGHTS:FRAME: 208 LBS.COVER: 120 LBS. 3/4" CEMENT MORTAR SEAL STD. M.H. RING & COVER 1'-0" OCM.H. STEPS @ 5 3/ 4 " 8" 1'-0" 1'-0" DOT APPROVED PRECAST 4" RISER RING PRECAST M.H. UNITS WITH CAST IN PLACE STEPS @ 12" OC TEMPORARY GRAVEL CONSTRUCTION ENTRANCE NTS PUB L I C R O A D COARSE AGGREGATE 2" - 3" 6" MIN.REQ U I R E D AS 50' M I N . 12' M I N . GEO FABRIC LINER CONSTRUCTION ENTRANCE TO BE 12' OR ENTIRE WIDTH OF NOTE: ENTRANCE. WHICHEVER IS GREATER. HARDWARE CLOTH AND GRAVEL INLET PROTECTION NTS 2' 2' 4' MAX. NCDOT #5 OR # 57 WASHED STONE 2: 1 16 " 19-GAUGE HARDWARE CLOTH (1/4 MESH OPENINGS) FILTERED WATER INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (12 INCH OR GREATER) RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER OBJECTS TO PROVIDE ADEQUATE FLOW FOR SUBSEQUENT RAINS. TAKE CARE NOT TO DAMAGE OR UNDERCUT THE WIRE MESH DURING SEDIMENT REMOVAL. REPLACE STONE AS NEEDED. MAINTENANCE: CONSTRUCTION SPECIFICATIONS: 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. 2. DRIVE 5-FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING THE INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET APART. 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE, AND BOTTOM. PLACINGA 2-FOOT FLAP OF WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS RECOMMENDED. 4. PLACE CLEAN GRAVEL (NCDOT #5 OR #57 STONE) ON A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES AROUND THE WIRE, AND SMOOTH TO AN EVEN GRADE. 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ACCUMULATED SEDIMENT, AND ESTABLISH FINAL GRADING ELEVATIONS. 6. COMPACT THE AREA PROPERLY AND STABILIZED IT WITH GROUNDCOVER. 4" CONC. SIDEWALK w/6x6-10/10 W.W.M. x 4"8" 4" x x x x x 8 4" ASPHALT TURNDOWN SIDEWALK NTS CLASS A CONC. 7"1/8"R 1"3"R 6" 1 1/2"R 3"R 1' - 0 " 2'-0" 1'-6"6" ASPHALT DRAINAGE AWAY FROM CURB CLASS A CONC. 24" CURB SECTION NTS ASPHALT 7" 2'-0" 3"R 1'-6" 1/8"R 1" 6" 6" 1' - 0 " DRAINAGE TOWARD CURB SHALL SLOPE AWAY AS SHOWN AWAY FROM CURB, GUTTER WHERE RUNOFF IS DIRECTED SLOPE SLOPE 1 1/2"R 3"R SIDEWALK SECTION A-A 4' min SECTION B-B A A B B 1.5±0.5%1.0-8.3% (30"MAX RISE) 10% MAX (X=36"MIN) 8.3% MAX (X<36") (FOR ALTERATIONS ONLY) RAMP CURB AND GUTTER WARNING DOMES 2' MIN 1.6-2.4" (TYP) RAMP WIDTH 0.2" Flare WARNING DOMES 1/2" EXPANSION JOINT (TYP) 4' FLARE WARNING DOME NOTES: 1. USE CONTRASTING COLORS, RED OR BLACK ON WHITE PAVEMENT. 2. USE CAST IN PLACE PAVERS FOR NEW CONSTRUCTION. 3. RUBBER MATS ARE PERMITTED FOR RETROFITS. 4. LANDING AND RAMP WIDTH MAY BE REDUCED TO 3' WHERE SPACE IS LIMITED AND DESIGN IS APPROVED BY THE CITY ENGINEER. X LAN D I N G 1.6-2.4" (TYP) TRUNCATED DOMES BASE DIAMETER 0.9-1.4" TOP DIAMETER 50-60% OF BASE (TYP) LANDING MIN. LANDING WIDTH = RAMP WIDTH MAX SLOPE 2% IN ANY DIRECTION NTS WHEEL CHAIR RAMP DETAIL DROP INLET DETAIL 3000 PSI CONC. NTS BRICK MASONRY FLOW 6" CONC. COLLAR 6" DROP INLET TO HAVE SAND LEAVE OPENING AS SHOWNTRAP, DROP FOOTING 12" & ELEV. VARIES ASPHALT PAVEMENT SECTION NOTE: 8" D 8"8" 1'-0" VA R I E S 4" CONC. COLLAR SEE PLAN FOR PIPEORIENTATION NOTE: USE DEWEY BROS. FOR YARD INLETSBASINS AND CH-BN-47CH-BN 3A FOR CATCH PLAN CASTING 6"6" STORM SEWER GRATE REINFORCED CORNERS MANAGEABLE 2 FOOT CONTAINMENT AREA LIFT STRAPS OPTIONAL OVERFLOW PORTS DUMPING STRAPS STORM INLET DANDY SACK TM DANDY SACK DETAIL NTS ENERGY DISSIPATOR NTS SECTION A - A FILTER FABRIC SEE PLAN SEE PLAN SE E P L A N 1. CLASS "B" RIP RAP TO BE USED FOR ALL ENERGY DISSIPATOR AREAS. NOTES: CONSTRUCTION SPECIFICATIONS: 1. Ensure that the subgrade for the filter and riprap follows the required lines and grades shown in the plan. Compact any fill required in the subgrade to the density of the surrounding undisturbed material. Low areas in the subgrade on undisturbed soil may also be filled by increasing the riprap thickness. 2. Filter cloth, when used, must meet design requirements and be properly protected from punching or tearing during installation. Repair any damage by removing the riprap and placing another piece of filter cloth over the damaged area. All connecting joints should overlap so the top layer is above the downstream layer a minimum of 1 foot. If the damage is extensive, replace the entire filter cloth. 3. Riprap may be placed by equipment, but take care to avoid damaging the filter. 4. The minimum thickness of the riprap should be 1.5 times the maximum stone diameter. 5. Riprap may be field stone or rough quarry stone. It should be hard, angular, highly weather-resistant and well graded. 6. Construct the apron on zero grade with no overfill at the end. Make the top of the riprap at the downstream end level with the receiving area or slightly below it. 7. Ensure that the apron is properly aligned with the receiving stream and preferably straight throughout its length. If a curve is needed to fit site conditions, place it in the upper section of the apron. 8. Immediately after construction,stabilize all disturbed areas with vegetation (Practices 6.10, Temporary Seeding, and 6.11, Permanent Seeding). MAINTENANCE: Inspect riprap outlet structures weekly and after significant (1/2 inch or greater) rainfall events to see if any erosion around or below the riprap has taken place, or if stones have been dislodged. Immediately make all needed repairs to prevent further damage. MIN. 12-1/2 GA. INTERMEDIATE WIRES TEMPORARY SILT FENCE NTS VARIES (6'-8' MIN.) AS DIR. BY ENG. STEEL POST FI L T E R F A B R I C WIRE FABRIC FILTER FABRIC 4" 8"6" ANCHOR FABRIC SKIRT AS DIRECTED BY ENGINEER CONSTRUCTION SPECIFICATIONS: MATERIALS: 1. Use a synthetic filter fabric of at least 95% by weight of polyolefins or polyester, which is certified by the manufacturer of supplier as conforming to the requirements in ASTM D 6461. Synthetic filter fabric should contain ultraviolet ray inhibitors and stabilizers to provide a min. of 6 months of expected usable construction life at a temp. range of 0-120° F. 2. Ensure that posts are 1.25#/linear ft. min. steel with a min. length of 5'. Make sure that steel posts have projections to facilitate fastening the fabric. 3. For reinforcement of standard strength filter fabric, use wire fence with a min. 14 ga. and a max. mesh spacing of 6". CONSTRUCTION: 1. Construct the sediment barrier of standard strength or extra strength synthetic filter fabrics 2. Ensure that the height of the sediment fence does not exceed 24" above the ground surface. (Higher fences may impound volumes of water sufficient to cause failure of the structure.) 3. Construct the filter fabric from a continuous roll cut to the length of the barrier to avoid joints. When joints are necessary, securely fasten the filter cloth only at support post with 4' min. overlap to the next post. 4. Support standard strength filter fabric by wire mesh fastened securely to the upslope side of the posts. Extend the wire mesh support to the bottom of the trench. Fasten the wire reinforcement, then fabric on the upslope side of the fence post. Wire or plastic zip ties should have min. 50# tensile strength. 5. When a wire mesh support fence is used, space posts a max. of 8' apart. Support posts should be driven securely into the ground a min. of 24". 6. Extra strength filter fabric with 6' post spacing does not require wire mesh support fence. Securely fasten the filter fabric directly to posts. Wire or plastic zip ties should have a min. 50 # tensile strength. 7.Excavate a trench approx. 4" wide and 8" deep along the proposed line of posts and upslope from the barrier. 8.Place 12" of the fabric along the bottom and side of the trench. 9. Backfill the trench with soil placed over the filter fabric and compact. Thorough compaction of the backfill is critical to silt fence performance. 10. Do not attach filter fabric to existing trees. MAINTENANCE: Inspect sediment fences at least once a week and after each rainfall. Make any required repairs immediately. Should the fabric of a sediment fence collapse, tear, decompose or become ineffective, replace it promptly. Remove sediment deposits as necessary to provide adequate storage volume for the next rain and reduce pressure on the fence. Take care to avoid undermining the fence during cleanout. Remove all fencing materials and unstable sediment deposits and bring the area to grade and stabilize it after the contributing drainage area has been properly stabilized. NTS 6" CONCRETE 4" ABC PARKING LOT PAVEMENT SECTION COMPACTED SUBGRADE C-5 6 DE T A I L S NTS EN G I N E E R I N G , P L L C IN T R A C O A S T A L REVISIONS Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 57 2 5 O l e a n d e r D r . U n i t E - 7 Ph o n e : 9 1 0 . 8 5 9 . 8 9 8 3 PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): Em a i l : C h a r l i e @ i n t r a c o a s t a l e n g i n e e r i n g . c o m 2024-007 FO R CLIENT INFORMATION: Reagan, LLC 303 Fox Lake Dr. Clinton, NC 28328 OF 10 JAE CDC CDC 24x36 10/23/2025 Li c e n s e N u m b e r : P - 0 6 6 2 NE W H A N O V E R C O U N T Y , N C RE A G A N R E T A I L A N D OF F I C E C E N T E R SITE CA S T L E H A Y N E R D CASTLE AVE. HOLLY SHELTER R D . PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N C-6 7 DE T A I L S NTS EN G I N E E R I N G , P L L C IN T R A C O A S T A L REVISIONS Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 57 2 5 O l e a n d e r D r . U n i t E - 7 Ph o n e : 9 1 0 . 8 5 9 . 8 9 8 3 PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): Em a i l : C h a r l i e @ i n t r a c o a s t a l e n g i n e e r i n g . c o m 2024-007 FO R CLIENT INFORMATION: Reagan, LLC 303 Fox Lake Dr. Clinton, NC 28328 OF 10 JAE CDC CDC 24x36 10/23/2025 Li c e n s e N u m b e r : P - 0 6 6 2 NE W H A N O V E R C O U N T Y , N C RE A G A N R E T A I L A N D OF F I C E C E N T E R SITE CA S T L E H A Y N E R D CASTLE AVE. HOLLY SHELTER R D . PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N 6" MINIMUM PERVIOUS CONCRETE SECTION #1 NTS IN SITU SOIL SUBGRADE #57 STONE (WASHED) 6" PERVIOUS CONCRETE NOTES: 1.SUBGRADE MUST BE EITHER SCARIFIED, RIPPED, OR TRENCHED TO MAINTAIN THE PRE-CONSTRUCTION SUBGRADE INFILTRATION RATE. 2.ACF M200 WOVEN GEOTEXTILE FABRIC TO BE INSTALLED BETWEEN SUBGRADE AND STONE BASE. 8" MINIMUM PERVIOUS CONCRETE SECTION #2 NTS IN SITU SOIL SUBGRADE #57 STONE (WASHED) 6" PERVIOUS CONCRETE NOTES: 1.SUBGRADE MUST BE EITHER SCARIFIED, RIPPED, OR TRENCHED TO MAINTAIN THE PRE-CONSTRUCTION SUBGRADE INFILTRATION RATE. 2.ACF M200 WOVEN GEOTEXTILE FABRIC TO BE INSTALLED BETWEEN SUBGRADE AND STONE BASE. IN SITU SUBGRADE 6" MIN. BASE LAYER 2" THICK BLOXX 2"SUPPORT LAYER ECORASTER BLOXX SECTION #1 NTS NOTES: 1.SUBGRADE MUST BE EITHER SCARIFIED, RIPPED, OR TRENCHED TO MAINTAIN THE PRE-CONSTRUCTION SUBGRADE INFILTRATION RATE. 2.ACF M200 WOVEN GEOTEXTILE FABRIC TO BE INSTALLED BETWEEN SUBGRADE AND STONE BASE. 3.ECORASTER BLOXX TO BE INSTALLED PER MANUFACTURER RECOMMENDED SPECIFICATIONS. IN SITU SUBGRADE 8" MIN. BASE LAYER 2" THICK BLOXX 2"SUPPORT LAYER ECORASTER BLOXX SECTION #2 NTS NOTES: 1.SUBGRADE MUST BE EITHER SCARIFIED, RIPPED, OR TRENCHED TO MAINTAIN THE PRE-CONSTRUCTION SUBGRADE INFILTRATION RATE. 2.ACF M200 WOVEN GEOTEXTILE FABRIC TO BE INSTALLED BETWEEN SUBGRADE AND STONE BASE. 3.ECORASTER BLOXX TO BE INSTALLED PER MANUFACTURER RECOMMENDED SPECIFICATIONS. IN SITU SUBGRADE 12" MIN. BASE LAYER 2" THICK BLOXX 2"SUPPORT LAYER ECORASTER BLOXX SECTION #3 NTS NOTES: 1.SUBGRADE MUST BE EITHER SCARIFIED, RIPPED, OR TRENCHED TO MAINTAIN THE PRE-CONSTRUCTION SUBGRADE INFILTRATION RATE. 2.ACF M200 WOVEN GEOTEXTILE FABRIC TO BE INSTALLED BETWEEN SUBGRADE AND STONE BASE. 3.ECORASTER BLOXX TO BE INSTALLED PER MANUFACTURER RECOMMENDED SPECIFICATIONS. 12" MINIMUM PERVIOUS CONCRETE SECTION #3 NTS IN SITU SOIL SUBGRADE #57 STONE (WASHED) 6" PERVIOUS CONCRETE NOTES: 1.SUBGRADE MUST BE EITHER SCARIFIED, RIPPED, OR TRENCHED TO MAINTAIN THE PRE-CONSTRUCTION SUBGRADE INFILTRATION RATE. 2.ACF M200 WOVEN GEOTEXTILE FABRIC TO BE INSTALLED BETWEEN SUBGRADE AND STONE BASE.