Loading...
HomeMy WebLinkAbout721 Piner Rd - Site PlanINV 6" ORIFICE=21.0± WATER SURFACE 3/26/24=21.3 YARD INLET RIM=25.91 DROP INLET RIM=25.58 CURB INLET RIM=25.94 CURB INLET RIM=26.02TOP OF BANK VA L L E Y C U R B EX. 6" C/O 15 ' D R A I N A G E E A S E M E N T 50 ' A C C E S S A N D U T I L I T Y E A S E M E N T 20' PUBLIC UTILITY EASEMENT RIGHT OF WAY WIDTH VARIES PINER ROAD X X X X X X X X X X X X X X X X X X X X X X X X EX. GRAVEL TO BE REMOVED EX . 5 ' S I D E W A L K PR O P O S E D L O T L I N E EX. F.H. BE N N E T T V I L L A G E L N . n/f DANNEN PROPERTIES, LLC BK 4980, PG 2385 Zoning: O&I Use: Vacant n/f BENNETT VILLAGE APARTMENTS, LLC BK 6207, PG 2432 Zoning: O&I Use: Apartments n/f REAVES BK 6084, PG 2709 Zoning: R-15 Use: Single Family Residential n/f BENDER NELLIE C LIFE ESTATE BK 1892, PG 0036 Zoning: R-15 Use: Vacant n/f OVERSTREET LAURA B BK 5424, PG 0230 Zoning: R-15 Use: Single Family Residential n/f MYRTLE GROVE PRESBYTERIAN CHURCH BK 6685, PG 0863 Zoning: R-15 Use: Single Family Residential n/f MYRTLE GROVE PRESBYTERIAN CHURCH BK 5647, PG 0611 Zoning: R-15 Use: Church LOT 1 INV=±18.3 EX . 8 " W A T E R M A I N EX. 8" WATER MAIN EX. 4 2 " R C P EX. 42" RCP EX. SSMH EX. 15' P.D.E EX. 18" RCP INV. 20.33 EX . 1 8 " R C P 26 26 27 27 27 27 27 27 27 27 S62°25'49"E 445.71' S1 8 ° 4 8 ' 0 6 " W 25 7 . 9 1 ' N62°25'49"W 484.96' 13" PINE 11" PINE 18" PINE 17" PINE 13" PINE 13" PINE 12"/5" GUM 14" OAK 7" OAK14" PINE 13" OAK 14"15" & 14" PINE 10"/8"/5" OAK 14" PINE 10" PINE 6" OAK 21" PINE 12" PINE 16" OAK 11"/10" GUM 26" LIVE OAK 23" PINE 16" PINE 22" PINE 15"14" PINE GUM 24" PINE 19" 18"12" 17" 15" PINE 15" PINE 12" PINE 14" PINE 17" PINE 17" PINE 13" PINE18" PINE 11" PINE 18" PINE 17"18"15"15" 17" 25" 5" 16" 11" 7" 17" OAK 18" PINE 21" PINE 11" OAK 13" OAK 16" PINE 18" PINE 18" 24" 17" 16" GUM 19" PINE 13" GUM 15" PINE 14" PINE 13" PINE 14" OAK 16" OAK17" PINE18" PINE 13" PINE 16" PINE 19" PINE 9" OAK 10" OAK 14" PINE 14" PINE 17" PINE 17" PINE 15" PINE 16" OAK 12" PINE 18" PINE 13" OAK 16" 24" 15" PINE 21" PINE 13" PINE 21" PINE 18" PINE 14" HOLLY 20" PINE 15" PINE 14" PINE 13" PINE 20" PINE 17" PINE 14" PINE 17" PINE 16" PINE 13" PINE 17" PINE 20" 17" PINE 18" PINE 18" PINE 10" PINE 11" GUM 16" PINE OAK CLUSTER 9" PINE 7" GUM 13" PINE 9" G U M 16" PINE 10" GUM 5" GUM 11" 12 " P I N E 7" OAK 12" PINE 4"5" OAK 6" OAK 11" OAK 4" OAK23 " P I N E 12" PINE 9" OAK 8" 10" 5" 30" 16" 7" 22"14" 17" 15"/8" 8" 7"15"18" PINE 12" OAK 14" 7" 13" 23" 18" 20" 18" PINE 17" PINE 12" PINE 7" OAK 10" OAK 19" PINE 23" PINE 15" PINE 19" PINE 16" PINE 17" PINE 17" PINE 23" PINE 25" PINE17" PINE 8"/8" OAK 22" PINE 13" PINE 21" PINE 13" PINE 20" PINE 17" PINE 12" PINE 19" PINE 20" 22" 22" 20" 11" PINE 15" PINE 6" G U M 6" GUM 19" 16" PINE 24" 22" PINE 12" OAK STORAGE SHED UNDER OPEN SHELTER 26 25 26 26 25 25 24 25 26 26 26 252423222223 24 25 25 25 26 DROP INLET RIM=25.55 DROP INLET RIM=24.51 DROP INLET RIM=23.86 DROP INLET RIM=24.67 DROP INLET RIM=25.43 INV=21.01 INV=21.05 INV=21.46 INV=21.45 18" RCP 18" RCP 18" R C P INV=21.01 INV=22.03 INV=22.28 MASONRY RESIDENCE #721 1 STORY FFE=28.15 26 (ELECTRIC) UTILITY STUB PR O P E R T Y L I N E T O B E A B A N D O N E D PR O P E R T Y L I N E T O B E A B A N D O N E D PINER LANDING OFFICE DEVELOPMENT UNDER CONSTRUCTION N2 7 ° 3 3 ' 2 5 " E 25 4 . 9 0 ' METER VAULT 20' PUBLIC UTILITY EASEMENT 15 ' D R A I N A G E E A S E M E N T DR I V E W A Y CO N C R E T E 133.43' TO HIGHGROVE PLACE R/W INV 6"=21.7± ICV SS SS SS SS SS BENCHMARK: "MAG" NAIL ELEVATION=26.72 (NAVD 88) 100' TAPER50' STORAGE EX. CURBING TO BE REMOVED 17" PINE EX. 18" RCP EX. 18" RCP EX.GRAVEL DRIVEWAY TO BE REMOVED CURB INLET RIM=26.47 CURB INLET RIM=26.47 TO BE REMOVED TO BE REMOVED C-0 1 EX I S T I N G C O N D I T I O N S , T R E E RE M O V A L / P R O T E C T I O N A N D DE M O L I T I O N P L A N 1" = 30' PROPERTY LINE ADJOINERS TREE PROTECTION FENCE LIMITS OF DISTURBANCE TREES TO BE REMOVED SIGNIFICANT TREES TO BE REMOVED PROPOSED DEMOLITION AREAS LEGEND EN G I N E E R I N G , P L L C IN T R A C O A S T A L REVISIONS Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 57 2 5 O l e a n d e r D r . U n i t E - 7 Ph o n e : 9 1 0 . 8 5 9 . 8 9 8 3 PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): Em a i l : C h a r l i e @ i n t r a c o a s t a l e n g i n e e r i n g . c o m 2025-00 FO R CLIENT INFORMATION: GL & SM Ltd. Partnership 5146 Masonboro Harbor Dr. Wilmington, NC 28409 OF 6 JAE CDC CDC 24x36 10/22/2025 Li c e n s e N u m b e r : P - 0 6 6 2 NE W H A N O V E R C O U N T Y , N C PI N E R L A N D I N G P H - I I SITE U S 4 2 1 B E A C H R D NC 1 3 2 S C O L L E G E R D MA S O N B O R O PI N E R R D GR O V E R D US 4 2 1 MY R T L E LO O P R D C A R O L I N A PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N SITE DATA PARCEL ID:R07600-002-191-000 & R07600-002-015-000 (TO BE RE-COMBINED) CURRENT ZONING:O & I PROJECT ADDRESS:721 PINER RD. WILMINGTON, NC 28409 CURRENT OWNER:GL & SM LTD. PARTNERSHIP 5146 MASONBORO HARBOR DR. WILMINGTON, NC 28409 ACREAGE IN EXISTING TRACT BOUNDARY 188,416 S.F. (± 4.33 ac.) ACREAGE IN PROP. PROJECT LOT BOUNDARY 118,612 S.F. (± 2.72 ac.) EXISTING ONSITE IMPERVIOUS AREAS: BUILDINGS 2,905 S.F. ROAD 2,885 S.F. GRAVEL 2,630 S.F. CONCRETE 135 S.F. TOTAL:8,555 S.F. EXISTING ONSITE IMPERVIOUS AREAS TO BE REMOVED: BUILDINGS 2,905 S.F. GRAVEL 2,630 S.F. CONCRETE 135 S.F. TOTAL:5,670 S.F. SOILS TYPE: Le (Leon sand - Group A) (Per NHC GIS Soil Map) NOTES: 1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY LAND DEVELOPMENT CODE. 2.PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS. 3.EXISTING SURVEYING PERFORMED BY C.I. GLOVER, PLS, L-4090 4.SITE IS LOCATED IN ZONE "X" PER FRIS ON FIRM MAP NUMBER 3720313400K, DATED 8/28/2018. 5.NO WETLANDS, SURFACE WATERS, PROTECTED VEGETATED SETBACKS OR RIPARIAN BUFFERS EXIST ON SITE. 6.PRIOR TO CLEARING, GRADING, OR CONSTRUCTION ACTIVITY, ANY WELLS THAT ARE EXISTING MUST BE PROTECTED AROUND EACH WELL HEAD/CASING AND CAPPED. 7.ALL PINE TREES ARE ASSUMED TO BE LOBLOLLY PINES. ALL GUM TREES ARE ASSUMED TO BE SWEET GUMS. CONTRACTOR TO VERIFY SPECIES PRIOR TO CUTTING. TREE PRESERVATION NOTES: 1.PRIOR TO ANY CLEARING, GRADING, OR CONSTRUCTION ACTIVITY, APPROVED TREE PROTECTION FENCING, SUCH AS SAFETY BARRIER FENCING, A WOODEN SLAT SNOW FENCE OR WIRE FENCE, SHALL BE INSTALLED AROUND PROTECTED TREES OR TREE STANDS LOCATED IN CONSTRUCTION AREAS OR OTHER SITE AREAS THAT WILL BE DISTURBED BY CONSTRUCTION ACTIVITIES. THE FENCING SHALL BE A MINIMUM OF FOUR FEET IN HEIGHT AND BE OF DURABLE CONSTRUCTION. TREE PROTECTIVE FENCING SHALL REMAIN IN PLACE THROUGH COMPLETION OF CONSTRUCTION ACTIVITIES. 2. NO CONSTRUCTION WORKERS, TOOLS, MATERIALS, OR VEHICLES ARE PERMITTED WITHIN THE TREE PROTECTION FENCING. 3.IF AN EXISTING TREE RETAINED TO COMPLY WITH THE STANDARDS OF THIS SECTION IS DESTROYED, SUBSTANTIALLY DAMAGED, OR DIES AS A RESULT OF NEGLIGENCE ON THE PART OF THE PROPERTY OWNER WITHIN THREE YEARS AFTER COMPLETION OF CONSTRUCTION, THEN REPLACEMENT TREES SHALL BE PLANTED ON THE SITE WITH A TOTAL DIAMETER EQUAL TO TWICE THE DIAMETER OF THE RETAINED TREE. A MINIMUM GROWING AREA OF 144 SQUARE FEET SHALL BE PROVIDED FOR EACH REPLACEMENT TREE. IF THE PLANNING DIRECTOR DETERMINES IT IS INFEASIBLE OR FOR REPLACEMENT TREE(S) TO BE ACCOMMODATED ON THE SITE, THEN A PAYMENT MAY BE MADE TO THE COUNTY’S TREE IMPROVEMENT FUND EQUIVALENT TO THE PRICING STANDARDS IN THE COUNTY FEE SCHEDULE. 60'30'15'30'0' Scale: 1"=30' = HOLLY TREE = LIVE OAK TREE = OAK TREE = MAGNOLIA TREE = PINE TREE = GUM TREE MITIGATION REQUIRED FOR REMOVAL OF SIGNIFICANT TREES QTY SIZE TYPE REPLACEMENT INCHES 1 26"LIVE OAK 52.00 1 25"PINE 50.00 1 24"PINE 48.00 1 14"HOLLY 28.00 TOTAL REPLACEMENT INCHES 178 CREDITS FOR PRESERVED TREES QTY DBH INCHES TYPE DOCUMENTED INCHES SIGNIFICANT INCHES CREDITS 1 14"LIVE OAK 14 21.00 1 16"OAK 16 24.00 2 15"OAK 30 45.00 1 14"OAK 14 21.00 3 8"OAK 24 36.00 1 7"OAK 7 10.50 2 5"OAK 10 15.00 1 4"OAK 4 6.00 1 23"PINE 23 34.50 2 22"PINE 44 66.00 1 20"PINE 20 30.00 1 19"PINE 19 28.50 3 18"PINE 54 81.00 1 17"PINE 17 25.50 1 16"PINE 16 24.00 2 15"PINE 30 45.00 1 12"PINE 12 18.00 1 11"PINE 11 16.50 1 10"PINE 10 15.00 TOTAL INCHES PRESERVED TREES 340 TOTAL CREDITS FOR PRESERVED TREES 510.0 YARD INLET RIM=25.91 DROP INLET RIM=25.58 CURB INLET RIM=25.94 CURB INLET RIM=26.02 VA L L E Y C U R B EX. 6" C/O 50 ' A C C E S S A N D U T I L I T Y E A S E M E N T RIGHT OF WAY WIDTH VARIES PINER ROAD X X X X X X X X X X X X X X X X X X X X X X X X EX . 5 ' S I D E W A L K PR O P O S E D L O T L I N E EX. F.H. BE N N E T T V I L L A G E L N . n/f BENNETT VILLAGE APARTMENTS, LLC BK 6207, PG 2432 Zoning: O&I Use: Apartments n/f REAVES BK 6084, PG 2709 Zoning: R-15 Use: Single Family Residential n/f OVERSTREET LAURA B BK 5424, PG 0230 Zoning: R-15 Use: Single Family Residential n/f MYRTLE GROVE PRESBYTERIAN CHURCH BK 6685, PG 0863 Zoning: R-15 Use: Single Family Residential n/f MYRTLE GROVE PRESBYTERIAN CHURCH BK 5647, PG 0611 Zoning: R-15 Use: Church LOT 1 INV=±18.3 10' X 70' NCDOT SIGHT TRIANGLE TYP.EX . 8 " W A T E R M A I N EX. 4 2 " R C P EX. 42" RCP EX. SSMH 26 26 27 27 27 27 27 27 27 27 14" 15" 19" 18"12" 17"17"18"15" 15" 17" 25" 5"16" 11" 7" 18" 24" 17" 16" 24" 20" 11"4" 8" 10" 5" 30" 16" 7" 22"14" 17" 15"/8" 8" 7"15" 14" 7" 13" 23" 18" 20" 20" 22" 22" 20" 19" 24" 26 25 26 26 25 25 24 25 26 26 26 252423222223 24 25 25 25 26 DROP INLET RIM=25.55 DROP INLET RIM=24.51 DROP INLET RIM=23.86 DROP INLET RIM=24.67 DROP INLET RIM=25.43 INV=21.01 INV=21.05 INV=21.46 INV=21.45 18" RCP 18" RCP 18 " R C P INV=21.01 INV=22.03 INV=22.28 26 (ELECTRIC) UTILITY STUB PINER LANDING OFFICE DEVELOPMENT UNDER CONSTRUCTION METER VAULT 20' PUBLIC UTILITY EASEMENT 15 ' D R A I N A G E E A S E M E N T DR I V E W A Y CO N C R E T E INV 6"=21.7± ICV 12 . 5 ' T Y P E - A B U F F E R W / 6 ' F E N C E DUMPSTER PAD & ENCLOSURE (SEE DETAIL) 25 ' 25 ' 24' 24' 25' 23 13 20 20 22 16 1111 21 12.5'PROP. 3-STORY BUILDING 13,125 SF FOOTRINT 8' SIDEWALK 8' SIDEWALK 8' S I D E W A L K 6' S I D E W A L K 2 UP 18 ' ( T Y P ) 9' (TYP) R2 5 ' (TY P ) UP 8' UPUP 8'5'8'9' 8'8' 5' 8'9' 25 ' 12 12 R 3 0 ' R5 0 ' 25 ' 25 ' EX. 18" RCP EX. 18" RCP SE C O N D A R Y S T R E E T Y A R D PRIMARY STREETYARD CURB INLET RIM=26.47 CURB INLET RIM=26.47 6" SSCO (TYP) TIE TO EX. 6" SSCO 6" S S S E R V I C E @ 1 . 0 % M I N . (1) 2" WATER SERVICE (36" MIN. BURY) (1) TIE TO EXISTING WATER MAIN W/ 2"X8" T.S.&V. 3' SEPARATION BETWEEN JOINTS, FITTINGS, SERVICE SADDLES AND WYES ARE REQUIRED FOR SS AND WATER TAPS. (1) 2" WATER SERVICE W/ 1.5" METER 18" INSIDE EXISTING P.U.E. & CFPUA APPROVED BACKFLOW PREVENTOR 6" SS SERVICE @ 1.0% MIN. LOT 2 C-1 2 PR E L I M I N A R Y S I T E P L A N 1" = 30' SITE DATA PARCEL ID:R07600-002-191-000 & R07600-002-015-000 (TO BE RE-COMBINED) CURRENT ZONING:O & I PROJECT ADDRESS:721 PINER RD. WILMINGTON, NC 28409 CURRENT OWNER:GL & SM LTD. PARTNERSHIP 5146 MASONBORO HARBOR DR. WILMINGTON, NC 28409 ACREAGE IN EXISTING TRACT BOUNDARY 188,416 S.F. (± 4.33 ac.) ACREAGE IN PROP. PROJECT LOT BOUNDARY 118,612 S.F. (± 2.72 ac.) PROPOSED USE:GENERAL OFFICE BUILDING SIZE:39,375 S.F. GFA TOTAL BUILDING HEIGHT:3-STORY/ ±35' CALCULATION FOR BUILDING COVERAGE: PROPOSED COVERAGE 13,125 S.F. ÷ 118,612 S.F. = 11.1% BUILDING SETBACKS: FRONT:REQUIRED= 25'PROPOSED=96' SIDE:REQUIRED= 25' Street/25' Interior to Res.PROPOSED= 118' L / 162'R REAR:REQUIRED= 30' To Res. Use PROPOSED= 83' PROPOSED IMPERVIOUS AREAS: BUILDINGS 13,125 S.F. ASPHALT PARKING/DRIVE AREA 57,230 S.F. CONCRETE SIDEWALK, C.&G., ETC.9,080 S.F. FUTURE 14,421 S.F. TOTAL 93,856 S.F (79.1%) PARKING REQUIRED: GENERAL OFFICE USE: (2.5/1,000 sf ) 39,325 SF/1000*2.5 = 98 SPACES PARKING PROVIDED:183 SPACES (6 ADA) PARKING LOT INTERIOR LANDSCAPING REQUIRED 57,230 S.F. * 8% 4,578 S.F. PROVIDED 5,052 S.F. FOUNDATION PLANTINGS: NORTH AND SOUTH FACADE REQUIRED 175 LF X 12' FACADE X 12%:252 S.F. PROVIDED:635 S.F. EAST AND WEST FACADE REQUIRED 75 LF X 12' FACADE X 12%:108 S.F. PROVIDED:292 S.F. STREETYARD PINER RD.: (18 S.F./LF FRONTAGE. 9' MIN./27' MAX. WIDTHS) 272 LF FRONTAGE 485- 21 LF ROADWAY = 464 LF FRONTAGE REQUIRED: 18' X 464 LF 8,352 S.F. PROVIDED:8,437 S.F. STREETYARD BENNETT VILLAGE RD.: (9 S.F./LF FRONTAGE. 4.5' MIN./13.5' MAX. WIDTHS) 255 LF FRONTAGE 255- 26 LF ROADWAY = 229 LF FRONTAGE REQUIRED: 9' X 229 LF 2,061 S.F. PROVIDED:2,250 S.F. EXISTING SEWER AND WATER DEMAND: 0 GPD PROPOSED SEWER AND WATER DEMAND:5,000 GPD ESTIMATED TRIP GENERATION (Per Trip Generation Manual): 39,375 SF GENERAL OFFICE (ITE CODE 710) AM PEAK: 60 PM PEAK: 57 DAILY: 427 EN G I N E E R I N G , P L L C IN T R A C O A S T A L REVISIONS Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 57 2 5 O l e a n d e r D r . U n i t E - 7 Ph o n e : 9 1 0 . 8 5 9 . 8 9 8 3 PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): Em a i l : C h a r l i e @ i n t r a c o a s t a l e n g i n e e r i n g . c o m 2025-00 FO R CLIENT INFORMATION: GL & SM Ltd. Partnership 5146 Masonboro Harbor Dr. Wilmington, NC 28409 OF 6 JAE CDC CDC 24x36 10/22/2025 Li c e n s e N u m b e r : P - 0 6 6 2 NE W H A N O V E R C O U N T Y , N C PI N E R L A N D I N G P H - I I SITE U S 4 2 1 B E A C H R D NC 1 3 2 S C O L L E G E R D MA S O N B O R O PIN E R R D GR O V E R D US 4 2 1 MY R T L E LO O P R D C A R O L I N A PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N DEVELOPMENT NOTES: 1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY LAND DEVELOPMENT CODE. 2.PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS. PROPERTY LINE RIGHT OF WAY EXISTING EDGE OF PAVEMENT EASEMENT PROPOSED WATERLINE PROPOSED FIRE LINE PROPOSED SANITARY SEWER LINE RUNOFF DIRECTION SPOT ELEVATION PARKING LOT LANDSCAPING STREETYARD LANDSCAPING FOUNDATION PLANTINGS LEGEND 25.5 60'30'15'30'0' Scale: 1"=30' FIRE & SAFETY NOTES: 1.CONSTRUCTION TYPE: TBD (COMMERCIAL) 2.PROPOSED BUILDING WILL NOT BE SPRINKLED. 3.CONTRACTOR SHALL MAINTAIN AN ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES DURING CONSTRUCTION. 4.BUILDING INFORMATION SIGNS MUST BE PROVIDED IN ACCORDANCE WITH THE "2018 NC FIRE CODE APPENDIX J" REQUIREMENTS. 5.CONTRACTOR SHALL SUBMIT A RADIO SIGNAL STRENGTH STUDY FOR ALL COMMERCIAL BUILDINGS THAT DEMONSTRATES THAT EXISTING EMERGENCY RESPONDER RADIO SIGNAL LEVELS MEET THE REQUIREMENTS OF SECTION 510 OF THE 2018 NC FIRE CODE. 6.ANY DRIVEWAY GATE TO BE SIREN ACTIVATED AND HAVE KNOX KEY OVERRIDE. 7.ALL FIRE HYDRANTS MUST BE INSTALLED WITH 5 INCH STORZ QUICK CONNECTS ON A 4.5 INCH STEAMER IN COMPLIANCE WITH NHC FIRE SERVICE REQUIREMENTS. 8.NO OBSTRUCTIONS WITHIN 36" AROUND A FIRE HYDRANT, INCLUDING BUT NOT LIMITED TO, STREET SIGNS, LANDSCAPING AND UTILITY POLES AND BOXES. 9.NEW HYDRANTS MUST BE BROUGHT INTO SERVICE PRIOR TO COMBUSTIBLE MATERIALS DELIVERED TO THE JOB SITE. 10.FIRE APPARATUS ACCESS ROADS SHALL PROVIDE A CLEAR VERTICAL CLEARANCE OF 14 FEET INCLUDING TREES, CANOPIES, BRIDGES, ETC. 11.DURING CONSTRUCTION, PREMISES IDENTIFICATION IS REQUIRED, AND MAY BE TEMPORARY IN NATURE PROVIDED IT IS LEGIBLE AND WEATHER RESISTANT. 12.PREMISES IDENTIFICATION IS REQUIRED. ADDRESS NUMBERS ARE REQUIRED ON THE STREET SIDE. NUMBERS SHALL NOT BE LESS THAN 6 INCHES TALL AND ¾ INCHES WIDE, MUST BE WEATHER RESISTANT, AND CONTRAST IN COLOR AGAINST THEIR BACKGROUND. UTILITY NOTES: 1.EXISTING WATER AND SANITARY SEWER SERVICES ARE CURRENTLY AVAILABLE TO THE SITE FROM CAPE FEAR PUBLIC UTILITY AUTHORITY PUBLIC MAINS. 2.ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS & TELEPHONE SHALL BE INSTALLED UNDERGROUND. 3.ALL WATER & SEWER UTILITIES TO BE INSTALLED PER CFPUA TECHNICAL SPECIFICATIONS & STANDARDS. 4.PROJECT SHALL COMPLY WITH CFPUA CROSS CONNECTION CONTROL REQUIREMENTS. WATER METER(S) CANNOT BE RELEASED UNTIL ALL REQUIREMENTS ARE MET AND N.C.D.E.N.R. HAS ISSUED THEIR "FINAL APPROVAL.". CALL 332-6558 FOR INFORMATION. 5.ANY BACKFLOW PREVENTION DEVICES REQUIRED BY THE CFPUA WILL NEED TO BE ON THE LIST OF APPROVED DEVICES BY USCFCCCHR OR ASSE. 6.IF CONTRACTOR DESIRES CFPUA WATER FOR CONSTRUCTION, HE SHALL APPLY IN ADVANCE FOR THIS SERVICE AND MUST PROVIDE A REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTION DEVICE ON THE DEVELOPER'S SIDE OF THE WATER METER BOX. 7.WHEN PVC WATER MAINS AND SERVICES ARE PROPOSED, THE PIPES ARE TO BE MARKED WITH NO. 10 INSULATED, SINGLE-STRAND COPPER WIRE INSTALLED & STRAPPED TO THE PIPES WITH DUCT TAPE. THIS IS TO BE ACCESSIBLE IN ALL VALVES AND METER BOXES TO AID IN FUTURE LOCATION OF FACILITIES. 8.SEWER GUARDS REQUIRED AT ALL MANHOLES. STAINLESS STEEL SEWER GUARDS REQUIRED AT MANHOLES LOCATED IN TRAFFIC AREAS. 9.SERVICES SHALL BE PERPENDICULAR TO MAIN AND TERMINATE AT RIGHT-OF-WAY LINE. SERVICES IN CUL-DE-SACS ARE REQUIRED TO BE PERPENDICULAR OR MUST ORIGINATE IN MANHOLE AND TERMINATE AT RIGHT-OF-WAY LINE. 10. ALL SERVICES TYING INTO DUCTILE IRON MAINS SHALL BE CONSTRUCTED OF CLASS 50 D.I.P. WITH PROTECTO 401 CERAMIC EPOXY LINING. 11.MINIMUM 10' UTILITIES EASEMENT PROVIDED ALONG THE FRONTAGE OF ALL LOTS AND AS SHOWN FOR NEW DEVELOPMENTS. 12.NO FLEXIBLE COUPLINGS SHALL BE USED. 13.ALL STAINLESS STEEL FASTENERS SHALL BE 316. 14.THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIES DURING CONSTRUCTION. CALL NC811 AT 811 OR 1-800-632-4949. CONTRACTOR IS RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ANY UTILITIES, CURB & GUTTER, PAVEMENT, ETC. THAT MAY BE BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIRED TO AT LEAST THE QUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM. 15.THE PROCESS FOR TELEPHONE CABLE PLACEMENT: * FINAL GRADE WILL NEED TO BE ESTABLISHED. * POWER WILL PLACE THEIR CABLE FIRST - APPROXIMATELY 3' DEEP. * BELLSOUTH & CABLE TV WILL THEN PLACE THEIR CABLE AT APPROXIMATELY 2' DEEP. 16.3' SEPARATION BETWEEN JOINTS, FITTINGS, SERVICE SADDLES AND WYES ARE REQUIRED FOR SS AND WATER TAPS. 17.ANY EXISTING SEWER AND WATER SERVICES NOT BEING UTILIZED ARE TO BE ABANDONED TO THE MAIN PER CFPUA STANDARDS. 18.SOLID WASTE DISPOSAL IS BY PRIVATE DUMPSTER SERVICE. C-3 4 DE T A I L S NTS EN G I N E E R I N G , P L L C IN T R A C O A S T A L REVISIONS Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 57 2 5 O l e a n d e r D r . U n i t E - 7 Ph o n e : 9 1 0 . 8 5 9 . 8 9 8 3 PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): Em a i l : C h a r l i e @ i n t r a c o a s t a l e n g i n e e r i n g . c o m 2025-00 FO R CLIENT INFORMATION: GL & SM Ltd. Partnership 5146 Masonboro Harbor Dr. Wilmington, NC 28409 OF 6 JAE CDC CDC 24x36 10/22/2025 Li c e n s e N u m b e r : P - 0 6 6 2 NE W H A N O V E R C O U N T Y , N C PI N E R L A N D I N G P H - I I SITE U S 4 2 1 B E A C H R D NC 1 3 2 S C O L L E G E R D MA S O N B O R O PI N E R R D GR O V E R D US 4 2 1 MY R T L E LO O P R D C A R O L I N A PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N SITE WORK NOTES: 1.THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS BOTH ON AND ADJACENT TO THE SITE. 2.CLEARING: CONTRACTOR SHALL REMOVE ALL TREES AND VEGETATION WITHIN LIMITS OF CONSTRUCTION UNLESS OTHERWISE DESIGNATED TO REMAIN. 3.GRUBBING AND STRIPPING: CONTRACTOR SHALL RAKE AND REMOVE ROOTS, STUMPS, VEGETATION, DEBRIS, EXISTING STRUCTURES ABOVE AND BELOW GRADE, ORGANIC MATERIAL OR ANY OTHER UNSUITABLE MATERIAL WITHIN LIMITS OF CONSTRUCTION. 4.MUCKING: CONTRACTOR SHALL COORDINATE WITH OWNER AND THEIR GEOTECHNICAL REPRESENTATIVE TO COORDINATE REMOVAL OF ANY SOFT AREAS. 5.DISPOSAL: CLEARED, GRUBBED, STRIPPED OR OTHER WASTE MATERIAL SHALL BE REMOVED FROM SITE AND DISPOSED OF IN A PROPERLY PERMITTED FACILITY. 6.FILL AND COMPACTION SHOULD COMPLY WITH GEOTECHNICAL RECOMMENDATIONS. 7.THE CONTRACTOR SHALL NOTE THAT THE GRADING PLAN MAY NOT REPRESENT A BALANCED EARTHWORK CONDITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CUT AND FILL QUANTITIES AND COMPLETE INSTALLATION TO SPECIFIED GRADES. 8.THE CONTRACTOR SHALL FURNISH SUITABLE BORROW MATERIAL FROM AN OFF-SITE PROPERLY PERMITTED FACILITY AS REQUIRED. 9.INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXACT ELEVATIONS AND LOCATIONS OF ALL EXISTING UTILITIES AT ALL CROSSINGS PRIOR TO COMMENCING TRENCH EXCAVATION. IF ACTUAL CLEARANCES ARE LESS THAN INDICATED ON PLAN, THE CONTRACTOR SHALL CONTACT THE DESIGN ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. ANY CONDITION DISCOVERED OR EXISTING THAT WOULD NECESSITATE A MODIFICATION OF THESE PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. 10.NO CONSTRUCTION IS TO BEGIN BEFORE LOCATION OF EXISTING UTILITIES HAS BEEN DETERMINED. CALL "NC ONE-CALL" AT LEAST 48 HOURS BEFORE COMMENCING CONSTRUCTION. 11.THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES DURING CONSTRUCTION. BEFORE COMMENCING ANY EXCAVATIONS IN OR ALONG ROADWAYS OR RIGHT-OF-WAYS, PUBLIC AREAS OR IN PRIVATE EASEMENTS, THE CONTRACTOR SHALL NOTIFY ALL APPROPRIATE PERSONNEL OF THEIR INTENT TO EXCAVATE, IN WRITING, NOT LESS THAN 10 DAYS PRIOR TO EXCAVATING. 12.THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE DISCONNECTION/ RECONNECTION AND/OR THE RELOCATION OF ALL EXISTING UTILITIES WITH APPROPRIATE PERSONNEL. 13.CONTRACTOR SHALL ADJUST ALL MANHOLES, VALVE & CURB BOXES TO FINAL GRADE UPON COMPLETION OF ALL CONSTRUCTION. ANY BOXES DAMAGED OR OTHERWISE DISTURBED BY THE CONTRACTOR SHALL BE REPAIRED AT THE EXPENSE OF THE CONTRACTOR. 14.THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AT THE SITE. FURTHERMORE THE CONTRACTOR SHALL REPORT ALL DISCREPANCIES OR QUESTIONS TO THE ENGINEER PRIOR TO INSTALLATION. 15.THE CONTRACTOR SHALL PROVIDE ANY AND ALL LAYOUT REQUIRED TO CONSTRUCT HIS WORK UNLESS OTHERWISE DIRECTED BY OWNER. 16.ALL SERVICE CONNECTIONS SHALL BE INSTALLED TO MEET ALL LOCAL, STATE, AND CFPUA CODES. METERS, TAPS, MATERIALS, WORKMANSHIP AND ALL FEES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL COMPLY WITH ALL REQUIREMENTS. 17.ALL BACKFILL FROM UTILITY INSTALLATION MUST BE COMPACTED OR AMENDED TO PROVIDE TRAFFIC BEARING CAPACITY. GEOTECHNICAL ENGINEER TO BE CONSULTED AT CONTRACTORS COST AS NECESSARY. 18.ALL AREAS SHALL BE GRADED FOR POSITIVE DRAINAGE. CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO INSTALLATION. ALL AREAS SHALL BE SLOPED TO DRAIN AWAY FROM BUILDINGS AT ALL TIMES. 19.CONCRETE FOR WALKS, CURBS AND DRIVES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI @ 28 DAYS - AIR ENTRAINED. 20.FIELD TESTING SHALL BE DONE BY AN INDEPENDENT TESTING LABORATORY PAID FOR BY THE OWNER. FURTHER TESTING REQUIRED DUE TO A FAILED TEST WILL BE PAID FOR BY THE CONTRACTOR. 21.ALL SIDEWALKS SHALL BE FREE OF CRACKS, BREAKS, OR ANY OTHER DEFECT PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. NTS 2" SF9.5A 8" ABC PAVEMENT SECTION COMPACTED SUBGRADE CURB INLET DETAIL NTS VA R I E S 3000 PSI CONC. FLOW SECTION 6" 4" 8" PRE-CAST CONC. ASPHALT PAVEMENT ELEV. VARIES 8"6"D 8"6" GROUT IN S I D E W A L L BO C OR EQUALDEWEY BROS. MODEL CH-BN-2001FRAME AND GRATE2" SEE PLAN FOR PIPE ORIENTATION & SIZES NCDOT STD. NO.840.03 ORAPPROVED EQUAL OF B O X DROP INLET DETAIL 3000 PSI CONC. NTS BRICK MASONRY FLOW 6" CONC. COLLAR 6" DROP INLET TO HAVE SAND LEAVE OPENING AS SHOWNTRAP, DROP FOOTING 12" & ELEV. VARIES ASPHALT PAVEMENT SECTION NOTE: 8" 2'-0"8"8" 1'-0" VA R I E S 4" CONC. COLLAR SEE PLAN FOR PIPEORIENTATION NOTE: USE DEWEY BROS. FOR YARD INLETSBASINS AND CH-BN-47CH-BN 3A FOR CATCH PLAN CASTING WHEEL STOP DETAIL NTS 1. CONTRACTOR SHALL INSTALL PER CITY OF WILMINGTON TECHNICAL STANDARD PER SD 15-13 NOTE: WIDTH x LENGTH x HEIGHT 1/2"1/2"6'-11" FRONT VIEW 7/8"Ø HOLES 1/2" END VIEW 4" 4.5" 1/2"8" 9" x 7'-0" x 4" 4000 PSI @ 4 - #4 REBAR 28 DAYS CONCRETE: REINFORCING: PLAN VIEW 12"7'12" 2. CONTRACTOR SHALL INSTALL WHEEL STOP 2.5' FROM SIDEWALK. 1-1/2"R(TYP) WHITE SYMBOL ON BLUE BACKGROUND LEGEND AND BORDER - GREENBACKGROUND - WHITE 9" 12" 3/8"(TYP) LEGEND AND BORDER - GREEN BACKGROUND - WHITE 18 " 12" COLORS 1-1/2"R(TYP) LEGEND AND BORDER - GREENBACKGROUND - WHITE 9" 18" 3/8"(TYP) TO READ "VAN ACCESSIBLE". BOLT TO WD. POST WITH 3/8" CANDIUM PLATED NUTS, BOLTS & WASHERS 9" x 1'-6" x .080 STD ALUM. SIGN NUTS, BOLTS & WASHERS. 9" x 1'-0" x .080 STD ALUM. SIGN TO READ "MAXIMUM PENALTY $250, GS 20-37.6". BOLT TO WD. POST WITH 3/8" CANDIUM PLATED PRESSURE TREATED 4"x4" POST. 3' - 0 " M I N . FINISHEDGRADE 84 " HANDICAPPED PARKING SIGN WITH IDENTIFICATION SYMBOL. 1'-6" x 1'-0" x .080 STD. ALUM. TO READ "RESERVED PARKING" BOLT TO WD. POST W/ 3/8" CANDIUM PLATED NUTS, BOLTS & WASHERS. TYPICAL HANDICAPPED SIGN DETAIL NTS R7-8a Sign (no arrows) R7-8d Sign R7-8P Sign 8" CONCRETE PAD W/CROSS-BRACING ENCLOSURE GATES 6X6 - 6/6 W.W.F. AT 3000 PSI W/ 3' 20'-0" 20 ' WOOD SIDING HORIZONTAL (TREATED) 4"X4" POSTS FOOTINGS CONCRETE 8" 8' 2"X6" CAP ASPHALT 10' 4"X4" POSTS ELEVATIONS PLAN DUMPSTER PAD & ENCLOSURE DETAIL NTS 3' 2' MIN. 12-1/2 GA. INTERMEDIATE WIRES SHALL HAVE A MIN. OF SIX LINE WIRES WITH 12" STAY 36" IN WIDTH. FABRIC SHALL BE FASTENED SELF-FASTENER STEEL ANGLE TYPE. 1. FENCE FABRIC SHALL BE A MIN. OF 32" IN WIDTH AND 2. FABRIC SHALL BE FOR EROSION CONTROL AND MIN. OF ADEQUATELY TO THE WIRE FABRIC AS DIRECTED BY THE 3. STEEL POST SHALL BE 5'-0" IN HEIGHT AND BE OF THE TEMPORARY SILT FENCE NTS SPACING. ENGINEER. NOTES: VARIES (6'-8' MIN.) AS DIR. BY ENG. STEEL POST FI L T E R F A B R I C WIRE FABRIC FILTER FABRIC 4" 8"6" ANCHOR FABRIC SKIRT AS DIRECTED BY ENGINEERTEMPORARY GRAVEL CONSTRUCTION ENTRANCE NTS PUB L I C R O A D COARSE AGGREGATE 2" - 3" 6" MIN.REQ U I R E D AS 50' M I N . 12' M I N . GEO FABRIC LINER CONSTRUCTION ENTRANCE TO BE 12' OR ENTIRE WIDTH OF NOTE: ENTRANCE. WHICHEVER IS GREATER. HARDWARE CLOTH AND GRAVEL INLET PROTECTION NTS 2' 2' 4' MAX. NCDOT #5 OR # 57 WASHED STONE 2: 1 16 " 19-GAUGE HARDWARE CLOTH (1/4 MESH OPENINGS) FILTERED WATER INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (12 INCH OR GREATER) RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER OBJECTS TO PROVIDE ADEQUATE FLOW FOR SUBSEQUENT RAINS. TAKE CARE NOT TO DAMAGE OR UNDERCUT THE WIRE MESH DURING SEDIMENT REMOVAL. REPLACE STONE AS NEEDED. MAINTENANCE: CONSTRUCTION SPECIFICATIONS: 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. 2. DRIVE 5-FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING THE INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET APART. 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE, AND BOTTOM. PLACINGA 2-FOOT FLAP OF WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS RECOMMENDED. 4. PLACE CLEAN GRAVEL (NCDOT #5 OR #57 STONE) ON A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES AROUND THE WIRE, AND SMOOTH TO AN EVEN GRADE. 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ACCUMULATED SEDIMENT, AND ESTABLISH FINAL GRADING ELEVATIONS. 6. COMPACT THE AREA PROPERLY AND STABILIZED IT WITH GROUNDCOVER. 4" CONC. SIDEWALK w/6x6-10/10 W.W.M. x 4"8" 4" x x x x x 8 4" ASPHALT TURNDOWN SIDEWALK NTS CLASS A CONC. 7"1/8"R 1"3"R 6" 1 1/2"R 3"R 1' - 0 " 2'-0" 1'-6"6" ASPHALT DRAINAGE AWAY FROM CURB CLASS A CONC. 24" CURB SECTION NTS ASPHALT 7" 2'-0" 3"R 1'-6" 1/8"R 1" 6" 6" 1' - 0 " DRAINAGE TOWARD CURB SHALL SLOPE AWAY AS SHOWNAWAY FROM CURB, GUTTER WHERE RUNOFF IS DIRECTED SLOPE SLOPE 1 1/2"R 3"R SIDEWALK SECTION A-A 4' min SECTION B-B A A B B 1.5±0.5%1.0-8.3% (30"MAX RISE) 10% MAX (X=36"MIN) 8.3% MAX (X<36") (FOR ALTERATIONS ONLY) RAMP CURB AND GUTTER WARNING DOMES 2' MIN 1.6-2.4" (TYP) RAMP WIDTH 0.2" Flare WARNING DOMES 1/2" EXPANSION JOINT (TYP) 4' FLARE WARNING DOME NOTES: 1. USE CONTRASTING COLORS, RED OR BLACK ON WHITE PAVEMENT. 2. USE CAST IN PLACE PAVERS FOR NEW CONSTRUCTION. 3. RUBBER MATS ARE PERMITTED FOR RETROFITS. 4. LANDING AND RAMP WIDTH MAY BE REDUCED TO 3' WHERE SPACE IS LIMITED AND DESIGN IS APPROVED BY THE CITY ENGINEER. X LAN D I N G 1.6-2.4" (TYP) TRUNCATED DOMES BASE DIAMETER 0.9-1.4" TOP DIAMETER 50-60% OF BASE (TYP) LANDING MIN. LANDING WIDTH = RAMP WIDTH MAX SLOPE 2% IN ANY DIRECTION NTS WHEEL CHAIR RAMP DETAIL