Loading...
HomeMy WebLinkAbout7241 Market St - Bank Lighting PlanSITE ELECTRICAL NOTES - GENERAL 1. EXACT LOCATIONS OF PARKING LOT LIGHTING STANDARDS SHALL BE COORDINATED WITH APPROVED ARCHITECTURAL SITE PLAN AND PARKING LOT LAYOUT. 2. ALL LIGHTING FIXTURES PROJECTING TOWARD ADJACENT RESIDENTIAL AREAS MUST BE PROPERLY SHIELDED TO PREVENT LIGHT SOURCE FROM EXTENDING INTO THIS AREA. 3. ALL SITE LIGHTING POLES SHALL BE DESIGNED TO WITHSTAND 100 MPH WINDS WITH A 1.3 GUST FACTOR. 4. ELECTRICAL CONTRACTOR SHALL INSTALL EACH LIGHTING POLE PLUMB AND TRUE. ELECTRICAL CONTRACTOR SHALL PROVIDE NECESSARY LEVELING SHIMS. 5. ELECTRICAL CONTRACTOR SHALL BACKFILL ALL ELECTRICAL TRENCHES USING CLEAN FILL MATERIAL FREE OF ORGANIC CONTAMINATIONS AND OTHER DELETERIOUS MATTER. PLACE BACKFILL MATERIAL IN 8" THICK LAYERS WITH EACH LIFT COMPACTED AT NEAR OPTIMUM MOISTURE CONTENT. COMPACT LIFTS TO ACHIEVE A MINIMUM IN PLACE DENSITY OF 95% OF THE MAXIMUM DENSITY AS DETERMINED BY ASTM D698. 6. ELECTRICAL CONTRACTOR SHALL COORDINATE LOCATION OF EASEMENTS, UNDERGROUND UTILITIES, AND DRAINAGE PRIOR TO TRENCHING OR AUGERING FOR POLE BASE. (TYPICAL) SITE ELECTRICAL NOTES - CHASE 1. CONTRACTOR SHALL COORDINATE WITH CHASE SECURITY VENDOR PLANS AND TC SERIES DRAWINGS FOR ALL FINAL LOCATIONS PRIOR TO ROUGH-IN. 2. MOUNT EXTERIOR CAMERAS TO AVOID BLOCKAGE BY THE AWNING. ALL 180 DEGREE CAMERAS TO BE SURFACE MOUNTED WITH RAIN HOOD. 3. EXTERIOR CAMERA WIRING SHALL BE RUN THROUGH A CONDUIT SYSTEM (IMC OR EMT) FROM THE BUILDING INTERIOR TO THE CAMERA LOCATION. CONDUIT SHALL BE CONCEALED FROM VIEW. EXTERIOR SURFACE-MOUNT CONDUIT IS GENERALLY NOT PERMITTED, AND ITS USE MUST BE APPROVED AS AN EXCEPTION BY THE OWNER. 4. EXTERIOR CAMERA CABLES THAT ARE INSTALLED IN LIGHT POLES SHALL PROVIDED CABLES THAT ARE LISTED FOR VOLTAGE RATING OF THE LIGHTING CONDUCTORS OR INSTALL IN SEPARATE RACEWAY INSIDE POLE. 5. BOND GROUNDING ELECTRODE CONDUCTOR IN POLE BASES TO EQUIPMENT GROUNDING CONDUCTOR RUN WITH CIRCUIT CONDUCTORS. 6. ALL SIGNAGE SHALL HAVE DISCONNECT SWITCH WITHIN SIGHT OF SIGN OR CIRCUIT BREAKER THAT OPENS ALL UNDERGROUND CONDUCTORS AND CONTROLS NO OTHER LOAD. PER NEC 600.6(A). LAMPSLOAD TYPE MANUFACTURERNO.(VA)TYPE SITE LIGHTING FIXTURE SCHEDULE CATALOGUE NUMBER DESCRIPTION LED1122P3-S LUMINAIRE: GE LIGHTING POLE: VALMONT STRUCTURES EACL-01-0-F3-AW-7-40-N-D-D1-BLCK-x W/ ELS-EACL-RBL-BLCK *DS340-450V250-D1-FP-BK-FBC-AB GE LIGHTING EVOLVE LED POLE AREA LIGHT FIXTURE WITH TYPE III ASYMMETRIC WIDE DISTRIBUTION. ZERO UPLIGHT, REAR SHIELDING, 70CRI, 4000K. 120V.COORDINATE MOUNTING ARM AND FINISH WITH ARCHITECT. * - FIELD VERIFY AND COORDINATE POLE & BASE SPECIFICATIONS WITH ARCHITECT FOR FINAL MOUNTING HEIGHT OF 20'-0". AVERAGE PHOTOMETRIC VALUES 5.9 MAXIMUM 19.2 MINIMUM 0.1 MAX/MIN 192:1 AVE/MIN 59:1 SYMBOLCALCULATION SITE ZONE SECTION PLAN AREA LIGHT FIXTURE POLE AND BASE SHROUD ASSEMBLY - REFER TO LIGHT FIXTURE SCHEDULE. CONCRETE POST BASE ANCHOR BOLT POSITIONS HT. OF CONC. POST BASE TO BE 3'-0" ABOVE FIN GRADE WHERE LOCATED WITHIN 24" OF PARKING SPACES IN CLIMATE ZONES 5-7 HAND HOLE AREA LIGHT FIXTURE POLE AND BASE SHROUD ASSEMBLY - REFER TO LIGHT FIXTURE SCHEDULE PREFERRED FINISH GRADE POSITION FINISH GRADE POSITION WHEN REQUIRED BY LOCAL CODE UNDISTURBED SOIL OR ENGINEERED COMPACTED FILL AS REQUIRED 3/4" X 25" X 3" HOT-DIPPED GALVANIZED STEEL THREADED ANCHOR BOLTS POLE BASE DETAIL N.T.S. COMPLY WITH A.C.I. MIN. CONCRETE COVER REQUIREMENTS AT OFF-PREMISES ATM PROJECTS, PROVIDE A 1" SEAL-TITE CONDUIT FROM SECURITY EQUIP. LOCATION CONDUITS FOR ELECTRICAL CIRCUITING AND GROUND ROD - REFER TO ELECTRICAL DRAWINGS AND FIXTURE SPECIFICATIONS FOR SIZES AND POSITIONS 1'-4" MIN. - VERIFYWITH CONCRETE CVR.REQS. POLE BASE DESIGN MUST BE APPROVED BY STRUCTURAL ENGINEER PRIOR TO INSTALLATION. SITE PHOTOMETRIC PLAN SCALE: 1" = 20' - 0" LED1244P4-2 LUMINAIRE: GE LIGHTING POLE: VALMONT STRUCTURES EACL-01-0-F4-AF-7-40-N-D-D1-BLCK-x *DS340-450V250-D2-FP-BK-FBC-AB GE LIGHTING EVOLVE LED POLE AREA LIGHT FIXTURE WITH TYPE IV ASYMMETRIC FORWARD DISTRIBUTION. ZERO UPLIGHT, 70CRI, 4000K. 120V.COORDINATE MOUNTING ARM AND FINISH WITH ARCHITECT. * - FIELD VERIFY AND COORDINATE POLE & BASE SPECIFICATIONS WITH ARCHITECT FOR FINAL MOUNTING HEIGHT OF 20'-0". L-7-R L-7-R L-7-R L-7-R L-7-R L-4 L-4 L-4 L-4 L-4 L-4 P4-2 P4-2 P4-2 P3-S P3-S P3-S P3-S P3-S P3-S P3-S P3-S P3-S P3-S PROPERTY LINE 0.3 0.1 0.9 0.8 0.3 0.1 1.7 1.5 0.7 0.1 0.1 0.1 2.4 3.3 2.4 1.5 0.5 0.2 0.2 0.2 3.6 4.5 4.1 4.0 2.1 0.7 0.4 0.3 0.3 0.3 2.9 4.2 5.0 6.2 7.2 6.2 2.1 1.7 0.8 0.7 0.6 2.6 3.8 4.4 5.0 6.6 9.5 9.4 6.9 5.9 2.9 2.1 1.9 1.6 2.9 3.9 4.8 5.8 6.8 8.4 8.6 10.2 8.6 5.2 4.4 3.8 2.9 1.6 0.7 2.1 2.8 3.5 4.6 6.0 8.1 7.8 8.3 8.4 7.4 7.0 6.2 5.8 4.3 2.6 1.3 0.7 1.9 2.3 2.7 3.1 3.8 5.4 6.7 7.8 8.5 6.9 6.3 6.6 7.2 7.0 5.6 4.9 2.9 1.0 0.9 0.6 2.7 2.7 2.8 2.9 3.3 4.2 5.1 6.4 6.7 6.8 6.3 6.6 6.9 6.9 7.3 7.8 6.8 4.2 2.2 1.3 0.9 2.9 3.7 3.7 3.1 3.0 3.3 3.6 3.9 4.5 5.1 5.6 6.2 6.8 6.8 6.5 7.3 9.7 11.0 8.1 6.8 3.4 2.2 1.6 1.4 3.8 4.9 4.8 3.9 3.5 3.4 3.2 3.3 3.4 3.8 4.5 5.5 6.2 6.6 7.0 7.7 9.4 9.9 11.1 10.6 6.1 4.4 3.1 2.1 1.2 3.1 4.9 5.9 5.0 4.6 4.3 3.6 3.1 2.9 2.9 3.2 3.7 4.5 5.2 5.8 7.1 9.0 9.7 9.7 10.5 9.3 7.5 5.9 4.4 2.8 1.5 0.9 2.1 6.1 8.7 6.6 5.3 5.1 4.3 3.6 2.9 2.6 2.5 2.7 3.2 3.6 4.0 4.8 6.3 8.0 9.4 11.0 10.0 8.7 7.2 6.4 4.7 2.8 1.7 4.8 8.0 9.9 7.8 6.4 5.7 4.2 3.1 2.5 2.3 2.2 2.4 2.7 3.0 3.4 4.1 5.2 6.6 8.5 9.9 10.3 9.0 8.1 6.8 4.6 3.0 1.7 3.0 6.5 9.9 8.4 7.8 8.0 5.7 3.9 2.7 2.1 1.8 1.9 2.0 2.2 2.6 3.1 3.8 4.9 6.0 7.9 9.2 9.5 8.6 8.7 7.3 5.0 2.9 2.7 5.0 8.5 9.1 8.3 8.0 7.0 5.5 3.5 2.5 1.9 1.6 1.6 1.7 1.9 2.3 2.9 3.7 4.7 6.2 8.3 9.7 8.9 9.0 8.8 6.3 4.1 4.6 5.8 7.0 6.8 7.0 7.8 6.2 4.2 3.0 2.2 1.7 1.4 1.3 1.5 1.8 2.2 2.7 3.6 4.8 6.9 8.5 9.5 9.7 10.8 9.4 5.6 2.8 4.3 6.0 7.1 6.5 6.1 6.7 6.0 4.8 3.4 2.6 1.9 1.8 4.0 4.1 2.3 1.9 2.3 2.9 3.7 5.0 7.0 9.2 8.9 9.6 11.0 7.3 3.5 2.6 4.9 6.7 7.1 6.7 6.4 6.0 5.0 3.7 2.7 1.3 0.9 10.1 14.0 8.5 4.0 2.7 3.2 4.1 5.4 6.9 7.6 8.8 10.9 9.0 5.4 3.7 5.8 7.0 6.5 6.6 6.7 5.7 4.2 3.1 15.5 8.2 3.8 3.9 4.9 5.7 6.4 6.4 7.7 9.6 6.8 2.8 2.8 6.4 9.0 7.1 6.2 6.4 5.9 5.0 3.8 2.8 6.2 4.0 4.5 5.7 6.4 6.2 6.3 6.9 6.2 4.1 2.2 9.0 10.0 7.9 6.9 6.5 5.2 3.9 3.2 2.5 1.1 6.5 6.5 6.4 6.3 6.7 6.5 4.8 2.6 3.5 7.2 9.9 8.7 8.4 8.3 6.2 4.4 3.2 2.5 13.6 8.4 6.2 6.6 6.6 5.7 4.1 3.0 5.5 9.3 9.6 8.6 8.5 7.4 5.8 3.8 2.8 19.2 9.3 6.5 6.9 5.5 4.4 4.9 6.4 7.5 7.4 7.7 8.2 6.5 4.5 3.3 2.4 6.0 17.1 14.9 8.9 8.4 6.7 4.2 2.7 5.1 6.7 7.5 6.8 6.5 7.2 6.4 5.1 3.7 2.8 8.2 10.9 9.4 9.7 10.1 6.1 2.8 3.2 5.5 7.5 7.7 7.1 6.8 6.4 5.5 4.1 3.1 6.6 8.2 8.6 9.4 10.1 7.7 4.4 5.3 7.0 7.3 6.9 7.1 7.2 6.1 5.5 6.0 3.4 6.3 7.5 8.1 7.9 9.7 10.7 6.3 1.1 3.2 7.2 9.5 7.5 6.7 6.9 6.3 6.0 8.9 11.7 7.2 8.4 8.1 8.1 9.0 7.0 3.8 6.2 10.4 10.1 8.3 7.7 6.7 5.8 7.7 12.4 6.6 8.0 8.1 8.6 9.2 8.6 5.9 2.6 5.6 9.3 10.5 9.0 8.8 8.6 6.5 5.1 9.1 12.3 7.9 8.6 8.0 8.4 9.3 7.2 4.5 4.4 6.7 10.2 10.3 9.5 9.4 7.7 6.0 4.5 6.3 9.5 7.6 9.3 9.1 9.5 9.9 7.0 5.0 6.1 8.0 8.6 8.7 9.2 9.1 7.2 5.1 4.1 3.8 6.1 5.8 2.2 6.5 9.3 9.2 8.9 10.6 10.3 5.9 2.8 5.4 6.6 7.7 8.2 8.9 9.5 8.1 6.3 5.0 3.9 3.2 2.7 2.0 1.7 1.6 1.8 16.0 11.3 9.2 10.4 10.4 6.5 3.4 4.8 5.8 6.1 7.0 8.4 9.1 8.9 8.1 6.4 5.1 4.1 3.2 2.5 2.0 2.0 2.0 2.4 5.7 18.6 15.3 9.2 8.6 10.6 9.5 5.7 5.5 6.1 6.4 7.6 8.7 9.2 8.4 7.5 7.0 5.9 4.6 3.5 2.9 2.7 2.6 2.7 3.0 6.4 11.3 11.5 15.9 11.7 9.0 8.8 9.2 6.7 3.2 4.8 5.6 5.9 6.8 10.1 10.6 9.1 8.3 7.9 7.2 6.3 5.1 4.1 3.6 3.4 3.3 3.9 4.4 5.6 8.0 9.7 10.7 9.2 9.3 9.7 7.8 5.1 5.3 5.3 5.9 8.7 11.3 11.6 11.2 10.3 9.0 7.9 6.5 5.3 4.8 4.6 4.4 4.3 4.7 5.4 6.4 8.3 9.6 9.2 8.7 9.2 8.9 6.7 5.2 5.8 5.7 6.8 9.6 10.6 10.7 11.9 12.2 11.7 9.9 7.2 6.2 5.9 5.5 5.2 5.2 5.7 6.7 8.1 9.4 10.6 10.0 10.5 10.5 6.9 4.4 4.5 5.5 5.7 6.7 9.6 10.4 9.6 9.5 11.1 12.7 12.9 11.1 9.2 8.3 7.5 6.7 6.2 6.2 6.9 7.9 9.8 11.0 10.2 10.0 11.5 9.1 5.0 5.0 5.1 5.5 7.7 11.1 12.3 11.5 11.6 10.1 11.9 11.8 10.5 10.5 10.5 9.5 8.4 7.9 8.2 8.5 9.5 10.3 11.2 10.7 11.6 11.1 6.5 2.8 4.8 5.3 5.5 6.2 7.9 10.3 11.6 13.0 14.1 14.5 13.7 11.4 10.6 10.7 10.8 10.4 10.2 10.5 10.7 11.0 10.3 10.5 10.5 10.7 11.6 8.5 4.0 4.3 5.0 5.3 6.2 7.9 9.1 9.7 10.2 12.6 14.1 14.8 14.8 14.2 13.3 11.3 10.5 10.4 11.8 12.1 12.7 12.2 11.6 11.2 10.8 9.8 9.4 6.2 5.0 4.9 5.2 6.9 8.9 10.1 10.6 11.4 11.4 12.6 13.6 14.4 15.3 15.6 14.0 11.9 11.4 11.6 12.9 12.0 12.5 13.7 12.7 9.5 8.4 6.3 3.8 4.9 5.6 5.5 6.1 7.6 8.9 9.9 11.1 12.3 12.7 12.3 12.5 14.0 14.7 14.2 14.2 14.8 13.5 11.6 10.7 12.3 12.8 13.5 9.7 7.0 5.6 4.6 4.1 5.0 5.4 6.2 8.8 9.9 9.3 9.1 10.7 12.1 13.0 13.2 13.7 13.8 12.9 11.6 12.9 15.0 13.7 11.0 10.5 12.4 13.6 8.5 5.4 3.6 3.0 4.5 4.9 5.0 6.7 10.3 11.1 10.9 10.6 10.0 10.7 11.6 13.3 14.2 14.4 11.7 10.9 12.9 13.0 11.8 10.5 10.6 11.5 8.9 5.1 2.6 2.1 1.8 4.0 4.9 4.8 5.3 8.0 9.1 10.1 11.2 11.7 12.1 11.3 9.8 10.9 13.2 13.6 12.2 12.4 11.8 10.3 8.7 9.6 9.7 8.2 5.3 2.8 1.8 1.3 3.9 4.6 5.1 7.2 9.7 8.8 7.4 9.3 11.2 12.5 11.9 9.8 9.5 9.9 11.0 12.2 12.1 11.0 8.1 7.5 7.7 8.0 5.7 3.5 2.0 1.3 1.0 2.8 3.2 3.5 5.0 8.3 9.6 9.2 8.3 7.7 10.2 11.0 9.9 9.6 10.1 9.0 8.4 8.8 9.9 8.9 7.0 6.5 6.3 5.8 4.1 2.4 1.4 1.0 2.1 2.6 2.8 3.2 4.5 6.8 8.3 9.1 9.5 9.7 9.7 8.8 7.6 8.5 9.3 8.7 7.6 6.7 6.3 5.6 5.7 5.6 5.3 4.0 2.9 1.8 1.1 1.9 2.4 2.8 3.3 4.4 5.3 5.4 7.0 8.6 9.6 9.4 6.7 6.2 7.0 7.5 7.2 6.7 6.1 4.7 4.1 4.2 4.6 3.8 2.8 2.0 1.3 0.8 1.2 1.5 1.9 2.6 3.7 4.4 4.5 4.6 5.0 6.5 7.9 7.1 5.7 5.9 5.9 5.6 5.1 5.1 4.7 4.1 3.6 3.4 3.2 2.5 2.0 1.4 0.9 1.1 1.4 2.0 2.9 3.8 4.2 4.2 4.6 5.0 4.9 4.4 4.6 5.3 4.9 4.0 3.5 3.4 3.3 3.3 3.1 2.9 2.3 1.7 1.4 1.0 1.0 1.5 2.0 2.5 3.2 4.0 4.4 4.3 3.6 3.3 3.7 4.1 3.7 2.9 2.5 2.2 2.2 2.3 2.5 2.3 1.8 1.4 1.0 0.7 1.0 1.4 1.7 2.1 2.7 3.4 3.6 3.1 2.9 3.1 3.0 2.5 2.0 1.7 1.6 1.6 1.7 1.7 1.6 1.4 1.1 0.8 0.9 1.1 1.4 1.8 2.2 2.3 2.5 2.6 2.6 2.3 1.8 1.5 1.2 1.2 1.2 1.2 1.2 1.1 1.0 0.8 0.6 0.7 0.9 1.2 1.4 1.5 1.8 2.0 2.0 1.7 1.4 1.1 1.0 0.9 0.9 0.9 0.8 0.8 0.7 0.6 0.6 0.8 0.9 1.0 1.3 1.4 1.4 1.3 1.1 0.9 0.8 0.7 0.7 0.7 0.6 0.5 0.5 0.5 0.6 0.7 0.9 1.0 0.9 0.9 0.8 0.7 0.6 0.6 0.6 0.5 0.5 0.4 0.3 0.4 0.5 0.6 0.7 0.6 0.6 0.6 0.5 0.5 0.5 0.4 0.4 0.3 0.3 0.4 0.5 0.5 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 SITE PHOTOMETRIC PLAN ES-102 JPM Chase Retail Banking Center NEC Wendover Ln. & Market St., Wilmington, NC 28411 Ogden Market Street - Entitlements PRINTED 11/3/2025 SHEET NUMBER SHEET TITLE PROJECT INFORMATION BLOCK CHECKED BY: DRAWN BY: DATE: JOB #:254019 09-29-2025 TBA ISSUE/BY DATE DESCRIPTION SEAL THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANYCAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS(HEREINAFTER“PLANS”) ARE THE SOLE AND EXCLUSIVE, PROPRIETARYPROPERTY OF BDG ARCHITECTS, AND MAY NOT BE REPRODUCED,PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESSWRITTEN PERMISSION OF BDG ARCHITECTS. USE OF THESE PLANS FORCONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMSCONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THEPLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSEWITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANYCHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THEEXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTIONEXECUTED FROM THESE PLANS WITHOUT THE EXPRESS WRITTENAPPROVAL OF BDG ARCHITECTS; OR ANY CHANGE IN THE SCOPE, DESIGN,OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHERTHAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANYDESIGN-RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THEPROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDGARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDINGERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS. ANYDISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERREDIMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR TOCONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES ORCONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALLRESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITHTHE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLEFOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORKAND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADESWITH THE DESIGN DOCUMENTS. 400 N. Ashley Dr. Suite 600 Tampa, FL 33602 P: 813-323-9233 FL Lic#AR-0014752 www.bdgllp.com CORPORATE LIC.# C-1335 TBA 3030 West Streetsboro Road Richfield, Ohio 44286 (330) 659-6688 Ph. (330) 659-6675 Fax Thorson Baker + Associates C O N S U L T I N G E N G I N E E R S \\tbs-projects25\2025\2025-1084\TBA-Cad-Revit\MEPT\2025-1084 ES-102.dwg,11/3/202510:23:24 AM