HomeMy WebLinkAbout2025-11-03 7031 Market street TRC submittalBATHROOM
UP
RECEPTION
KITCHEN
CLOSET
OFFICE
L
O
2
4
L
O
2
4
T
V
46
46
46
46 46
45
45
4
5
45
4
5
45
45
45 45
44
44
44
44
43
UT UT UT UT UT UT UT UT UT UT UT UTUGUGUG
UG
UG UG UG UG
UG
UG UG UG UG UG UG UG UG UG
45
45
46
47
45
46
47
48
48
46
47
45
46
47
46
47
SURVEY REFERENCE
L
O
K
3
6
O
K
2
2
LO
K
2
8
L
O
K
3
8
L
O
K
3
0
L
O
K
3
0
W
S
S
S
S
S
S
18'-0"22'-0"
8'
-
0
"
9'
-
0
"
5'-0"
1314
RE
G
I
S
T
E
R
ED L A N D S CA
P
E
A
R
C
H
ITECT
X
N O R
T H C A RO
LI
N
A
X
J
O
S
H
UA W . M I H A LY
Revisions
MIHAL Y
LAND DESIGN
PLANNING + LANDSCAPE ARCHITECTUR E
330 MILITARY CUTOFF RD., Suite A 3
Wilmington, NC 28405 910.392.435 5
of sheets
Job Number:
Phase:
Date:
Checked by:
Drawn by:
Designed by:
Sheet Title:
Sheet Number:
PR
O
J
E
C
T
MI
H
A
L
Y
L
A
N
D
D
E
S
I
G
N
O
F
F
I
C
E
70
3
1
M
A
R
K
E
T
S
T
R
E
E
T
WI
L
M
I
N
G
T
O
N
,
N
C
SI
T
E
P
L
A
N
2025-11-03
101-510
3
TRC PLAN SET
ADDRESS 7031 MARKET STREET
PARCEL ID:R04400-002-015-000
PROPOSED USE:OFFICE
EXISTING ZONING:CD-B2
EXISTING LAND USE:VACANT LOT
PARCEL AREA:.34 ACRES (14,810 SF)
CAMA URBAN MIXED USE
OWNER:CHASE & DYLAN MIHALY LLC
NUMBER OF BUILDINGS:1
0
SCALE:
feet204060
1" = 20'N O R T H
SITE PLAN
MLD
ALM
JWM
L1.0
SITE DATA
MARKET STREET
BULK REQUIREMENTS REQUIRED PROVIDED
MAX. FAR 40%7%
MIN. FRONT SETBACK 25'80'
MIN. REAR SETBACK 0'90'
MIN. INTERIOR SIDE SETBACK
NORTH SIDE SETBACK 0'48'-8"
SOUTH SIDE SETBACK 0'2'
MAX. BUILDING HEIGHT 50'30"
BUFFER REQUIREMENTS 0 0
OFF-STREET PARKING REQUIREMENTS
REQUIRED PROVIDED
OFFICE:
MIN: 2.5 spaces / 1000 sf
(2,160 SF/400)6 11
HANDICAP PARKING (1/25 SPOTS): 1 1
TOTAL:7 12
SITE IMPERVIOUS
PROVIDED
BUILDING:1,200 SF
CONCRETE PAVING/ SIDEWALK:827 SF
GRAVEL PARKING:3,961 SF
TOTAL:5,988 SF
SYMBOL LEGEND
PROPOSED GRAVEL PARKING AREA
PROPOSED CONCRETE PAVING
EASMENT LINE
SEWER
WATER
EXISTING POWER POLES
W W
EXISTING NC DOT APPROVED
DRIVEWAY LOCATION
(APPROVED AS PART OF CONDITIONAL
USE APPLICATION FOR NIXON
APARTMENT SITE)
EXISTING TREES
TO REMAIN
PROPOSED
OFFICE
FFE 45.50
GRAVEL
PARKING
12 SPACES
EXISTING TREES
TO REMAIN
EXISTING NC DOT DRIVEWAY LOCATION
EX
I
S
T
I
N
G
D
R
I
V
E
W
A
Y
45
45
45.50
S4
7
°
0
0
'
0
0
"
E
(
B
A
S
E
B
E
A
R
I
N
G
)
N/F LEES CUT INVESTMENTS, LLC
ZONING: B2 BUISNESS DISTRICT
19
5
.
4
6
'
S43°49'40"W 68.10'
N5
3
°
5
0
'
5
4
"
W
N47°33'40"E
91.69'
DI
S
T
R
I
B
U
T
I
O
N
L
I
N
E
N47°24'19"E
45.00
45.35
45.25 45.15
45.1045.20
44.60
44.80
44.90
VICINITY MAP
NORTH
SITE
MAR
K
E
T
S
T
GOR
D
O
N
R
D
MI
D
D
L
E
S
O
U
N
D
L
O
O
P
R
D
RUTH
A
V
E
MIL
I
T
A
R
Y
C
U
T
O
F
F
R
D
EL O
G
D
E
N
D
R
SS
CURB STOP (TYP)
HANDICAP SIGN
UTILITY EASEMENT
25' FRONT SETBACK
PROPOSED SIGN LOCATION
OLYMPUS HOLDING
COMPANY MARKET STREET
ZONING: RMF-M-RES
MULTI-FAM MOD DENS
EXISTING STORM
WATER CATCH BASIN
EXISTING WELL
EXISTING SEWER
CONNECTION
1314
RE
G
I
S
T
E
R
ED L A N D S CA
P
E
A
R
C
H
ITECT
X
N O R
T H C A RO
LI
N
A
X
J
O
S
H
UA W . M I H A LY
Revisions
MIHAL Y
LAND DESIGN
PLANNING + LANDSCAPE ARCHITECTUR E
330 MILITARY CUTOFF RD., Suite A 3
Wilmington, NC 28405 910.392.435 5
of sheets
Job Number:
Phase:
Date:
Checked by:
Drawn by:
Designed by:
Sheet Title:
Sheet Number:
PR
O
J
E
C
T
MI
H
A
L
Y
L
A
N
D
D
E
S
I
G
N
O
F
F
I
C
E
70
3
1
M
A
R
K
E
T
S
T
R
E
E
T
WI
L
M
I
N
G
T
O
N
,
N
C
SI
T
E
P
L
A
N
2025-11-03
101-510
3
TRC PLAN SET
SITE DETAILS
MLD
ALM
JWM
L2.0
NOT TO SCALE
UNPAVED PARKING FACILITY - UNDER 25 STALLS
ACCESSIBLE PARKING SIGNS MOUNTING
SIDEWALK DETAIL
TREE PROTECTION (TYP)ACCESSIBLE PARKING SIGNS
TREE PLANTING
FILLED EXPANSION JOINT FILLED EXPANSION JOINT
SECTION A-A
CONTROL JOINT
FILLED EXPANSION JOINT
SECTION B-B
SCORE
NOTES:
1. JOINT MATERIAL TO COMPLY WITH CURRENT NCDOT STANDARDS.
2. SANITARY SEWER CLEAN-OUTS, WATER METERS, MANHOLES, AND VALVE LIDS TO BE LOCATED OUTSIDE
SIDEWALK WHERE FEASIBLE.
3. MINIMUM SIDEWALK WIDTH TO BE 6' MINIMUM IF PLACED AT BACK OF CURB.
4. CONCRETE FOR ALL SIDEWALKS (EXCEPT ANY PORTION CONTAIN WITHIN A DRIVEWAY
5. MINIMUM REPLACEMENT FOR REPAIRS IS A 5' X 5' PANEL
6. 4" STONE BASE MAY BE REQUIRED FOR POOR SOIL CONDITIONS
7. MINIMUM DEPTH FOR TUNNELING BELOW SIDEWALK IS 12"
8. MAX ADJACENT GROUND SLOPE WITHOUT RAILING IS 2:1
9. MIN GRADE FOR PROPER DRAINAGE IS 1% IN AT LEAST 1 DIRECTION. MAX CROSS SLOPE IS 2%. MAX
LONGITUDINAL SLOPE IS 8.3%, 10% IF LIMITED BY EXISTING CONDITIONS, OR NO GREATER THAN THE SLOPE
OF THE EXISTING ADJACENT ROAD.
BATHROOM
UP
RECEPTION
KITCHEN
CLOSET
OFFICE
4R
OHEOHEOHEOHEOHEOHEOHE
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
L
O
2
4
L
O
2
4
T
V
46
46
46
46 46
45
45
4
5
45
45
45 45
44
44
44
43
UT UT UT UT UT UT UT UT UT UT UT UT
UG
UG
UG UG UG UG
UG
UG UG UG UG UG UG UG UG UG
45
46
47
45
46
47
48
48
46
47
45
46
47
46
47
MAP BOOK 45 PAGE 296
SURVEY REFERENCE
DEED BOOK 943 PAGE 175
MAP BOOK 49 PAGE 189MAP BOOK 52 PAGE 138-144
DEED BOOK 5972 PAGE 653
DEED BOOK 1497 PAGE 495
L
O
K
3
6
O
K
2
2
L
O
K
2
8
L
O
K
3
8
L
O
K
3
0
L
O
K
3
0
W
S
S
S
S
S
S
18
7
.
7
6
'
OH
P
UGG
OHP
EXISTING WELL
DU
K
E
P
O
W
E
R
10
0
'
W
I
D
E
T
R
A
N
S
M
I
S
S
I
O
N
L
I
N
E
E
A
S
E
M
E
N
T
37.5' MAX. STREET YARD
12.5' MIN. STREET YARD
1314
RE
G
I
S
T
E
R
ED L A N D S CA
P
E
A
R
C
H
ITECT
X
N O R
T H C A RO
LI
N
A
X
J
O
S
H
UA W . M I H A LY
Revisions
MIHAL Y
LAND DESIGN
PLANNING + LANDSCAPE ARCHITECTUR E
330 MILITARY CUTOFF RD., Suite A 3
Wilmington, NC 28405 910.392.435 5
of sheets
Job Number:
Phase:
Date:
Checked by:
Drawn by:
Designed by:
Sheet Title:
Sheet Number:
PR
O
J
E
C
T
MI
H
A
L
Y
L
A
N
D
D
E
S
I
G
N
O
F
F
I
C
E
70
3
1
M
A
R
K
E
T
S
T
R
E
E
T
WI
L
M
I
N
G
T
O
N
,
N
C
SI
T
E
P
L
A
N
2025-11-03
101-510
3
TRC PLAN SET
0
SCALE:
feet204060
1" = 20'N O R T H
PLANTING PLAN
MLD
ALM
JWM
L3.0
MARKET STREET
SYMBOL LEGEND
EXISTING NC DOT APPROVED
DRIVEWAY LOCATION
(APPROVED AS PART OF CONDITIONAL
USE APPLICATION FOR NIXON
APARTMENT SITE)
EXISTING TREES
TO REMAIN
PROPOSED
OFFICE GRAVEL
PARKING
EXISTING TREES
TO REMAIN
EXISTING NC DOT DRIVEWAY LOCATION
EX
I
S
T
I
N
G
D
R
I
V
E
W
A
Y
UTILITY EASEMENT
25' FRONT SETBACK
PROPOSED GRAVEL PARKING AREA
PROPOSED CONCRETE PAVING
EASMENT LINE
STREETYARD LINE
SEWER
WATER
EXISTING POWER POLES
W W
SS
LANDSCAPE REQUIREMENTS
PARKING REQUIEMENTS REQUIRED PROVIDED
8% OF PARKING AREA
3961 SF x .08 317 SF 568 SF
STREET YARD REQUIREMENTS
MULTIPLIER: 12.5
MARKET STREET 68.10 LF x 12.5 851.25 SF 1616 SF
CANOPY TREES (1/600)2 2
SHRUBS (6/600)9 9
FOUNDATION REQUIREMENTS
12% FACADE
EAST 25 LF x 12 HT x.12 36 SF 225 SF
NORTH 50 LF x 12 HT x.12 72 SF 202 SF
ALL PARKING LOT SCREEN PLANTINGS
SHALL BE 3' HT MIN. AT TIME OF PLANTING
SYMBOL BOTANICAL / COMMON NAME CONT CAL QTY
TREES
Taxodium distichum / Bald Cypress B & B 2.5" CAL 3
STREETYARD TREES
Quercus virginiana / Southern Live Oak B & B 2.5" CAL 1
SYMBOL BOTANICAL / COMMON NAME CONT SIZE QTY
SHRUBS
Cleyera japonica / Cleyera 3 gal 18-24" HT 13
Fatsia japonica / Japanese Fatsia 7 gal 24-30" HT 12
Pittosporum tobira / Pittosporum 7 gal 18-24" HT 15
Sabal minor / Dwarf Palmetto 7 gal 18-24" HT 13
PLANT SCHEDULE