HomeMy WebLinkAbout5012 Carolina Beach Rd - Contractor Office - TRC Comments Contractor Office – 5012 Carolina Beach Road – TRC Review Page | 1 To: Johnathon Earle, JEMS Holding LLC From: Amy Doss, Development Review Planner Date: December 3, 2025 Technical Review Committee (TRC) PID#: R07117-003-005-000, & R07117-003-005-001 Egov# SITECN-25-000109 Subject: 5012 Carolina Beach Road – Contractor Office - TRC Review Technical Review Committee (TRC) General Information The TRC is a staff-level group of local government officials that reviews projects for compliance with the local regulations administered by each respective review agency. Voluntarily participating state agencies may also provide comments. And general information and non-binding recommendations about the site may also be provided by government agencies. The TRC meetings are considered staff meetings and are not public hearings. The TRC meeting is an opportunity for applicants to speak with county staff and any voluntarily participating state or federal agencies about the review comments they have been provided. No voting is involved in the TRC process, and no final approvals or denials are made at the TRC meetings. Following the TRC meeting, applicants are responsible for updating their plans to address review comments. Those revised plans need to be resubmitted to the assigned case planner. The case planner will facilitate additional reviews until all comments have been addressed, and the necessary departments have stated the plans comply with the applicable minimum requirements for development. Following any future TRC approval, the project is required to obtain additional permits to include a zoning compliance permit for the site. Applicants are also responsible for coordinating with state and federal agencies for compliance with any additional requirements. Any activity on the property that is not approved as part of the TRC review and zoning compliance permit will be considered a violation of the UDO and subject to enforcement action under Article 12 Violations and Enforcement. The following comments have been received for the December 3, 2025, TRC meeting. Additional comments may be made upon further review of subsequent revisions. Contractor Office – 5012 Carolina Beach Road – TRC Review Page | 2 Planning, Amy Doss 910-798-7571 Compliance with local UDO requirements 1. General Comments a. Zoning district is B-2, Regional Business. b. As stated in the application the intended use is Contractor Office and Warehousing. The Unified Development Ordinance (UDO) defines the uses as: i. Contractor Office: An establishment primarily engaged in the day-to-day administrative and clerical services for businesses providing contracted services, such as building contractors, heating and air conditioning (HVAC) repair, landscaping and janitorial services, etc., that require outside and/or fleet storage. The use may include some on-site repair and material preparation work. ii. Warehousing: The storing of goods, wares, and merchandise within an enclosed building, whether for the owners or others. There is little on-site sales activity with the customer present. Uses include: cold storage facilities (including frozen food lockers); distribution warehouses (used primarily for temporary storage pending distribution in response to customer orders); storage warehouses (used for storage by retail stores such as furniture and appliance stores); warehouse storerooms; or similar uses. c. The Planning and Land Use Department’s review of the site is for compliance with the UDO and use specific requirements of the specified land use. Any other activity that might occur on the property beyond the definition above should be noted on the application and site plan for additional review and comment. 2. UDO Section 5.1, Parking and Loading a. Contractor Office use requires 3 parking spaces for every 1,000 square feet of building area. Project proposes 1,200 square feet of Contractor Office. Required parking is 1,200 / 1,000 = 1.2 x 3 = 4 required parking spaces. b. Warehousing use requires 1.5 parking spaces for every 1,000 square feet of building area. Project proposes 2,800 square feet of Warehousing. Required parking is 2,800 / 1000 = 2.8 x 1.5 = 4 required parking spaces. c. Project requires 8 spaces and provides 11 spaces. 3. UDO Section 5.2, Traffic, Access and Connectivity Contractor Office – 5012 Carolina Beach Road – TRC Review Page | 3 a. Please note that no building permit for any structure shall be issued which requires NCDOT approval for a Driveway Permit until NCDOT has issued the permit approval. Evidence of approval shall accompany the application for building permit. b. The WMPO has estimated 7 AM and 8 PM peak hour trips. 4. UDO Section 5.3, Tree Retention a. Please submit a tree removal permit application when ready. b. Note: Land disturbance permits can be issued by county Engineering before a Tree Removal Permit is approved by Planning. However, any trees removed before the Tree Removal Permit is issued may result in enforcement action under Section 5.3.2 of the Unified Development Ordinance to include prohibiting any development of the site for 3 to 5 years. 5. UDO Section 5.4, Landscaping and Buffering a. Street yard landscaping required: 25 sq ft x 64 linear feet = 1,600 sq ft. 1,630 sq ft provided. For every 600 sq ft of street yard required, one canopy tree and 6 shrubs must be provided. Please provide this on the landscape plan. b. Parking lot landscaping required: 8,970 sq ft x 8% = 718 sq ft required, 1,410 sq ft provided. Please note at least 75% of trees required must be a canopy species. Please provide tree species and count. c. Foundation landscaping required: 40 linear feet x 15 foot façade x 12% = 72 sq ft required. 82 sq ft provided. d. All planting materials must comply with the approved planting materials listed in the New Hanover County Tree & Landscaping Manual. The species and size must be listed in the final landscape plan indicating compliance with the manual. Or evidence the proposed plant species are acceptable from the county Agricultural Extension office. 6. UDO Section 5.5, Lighting a. Please note that a lighting plan is not required for TRC approval but will be required prior to issuance of construction plan approvals. b. Is any lighting proposed for the site? 7. UDO Section 5.6, Signs a. As noted on page C-1, for any signs on the site, a separate sign permit must be submitted and reviewed by the county for compliance with Section 5.6 of the UDO for standards at or after the submittal of the separate zoning compliance and construction permits for the primary building or use. Contractor Office – 5012 Carolina Beach Road – TRC Review Page | 4 8. UDO Section 5.7, Conservation Resources a. The conservation resources map does not indicate any conservation resources impacting the property, this section does not apply. 9. UDO Article 9, Flood Damage Prevention a. Property is not within the floodplain. NHC Fire Services, David Stone 910-798-7458 Compliance with NC Fire Code 1. The complete TRC/Site plans comments from New Hanover County Fire staff shall be submitted along with the building plans for review to New Hanover County Building Safety. This shall include the complete set of civil plans. Failure to submit the comments or complete set of civil plans will result in a resubmittal for review for verification of compliance. 2. A fire hydrant must be located within 400 feet of a newly constructed structure. Please show an existing hydrant that meets this requirement or proposed location of a new hydrant. NHC Soil & Water Conservation, Reviewer 910-798-7138 General comments about existing soil conditions of the site. 1. Comments forthcoming. NHC Engineering, Galen Jamison 910-798-7072 Stormwater management and land disturbance 1. A County stormwater and land disturbing permit issued by the County is required for this project. Please digitally submit the permit applications documentation with requisite review fees to the COAST online permit portal (https://newhanovercountync- energovpub.tylerhost.net/apps/selfservice#/home). Applicable forms can be found at https://www.nhcgov.com/251/Stormwater-Permitting and https://www.nhcgov.com/249/Sediment-Erosion-Control. 2. What is the stormwater permitting intent, as no SCM is shown on the site plan? 3. Please contact the State for their stormwater permit requirements. It is anticipated a new high density permit will be required. Contractor Office – 5012 Carolina Beach Road – TRC Review Page | 5 NHC Environmental Health, Dustin Fenske 910-798-6732 Septic tanks and wells 1. Site plan states connection to a private drinking water well. New wells must be applied and permitted through NHC Environmental Health prior to issuance of building permit. Records reflect an old well on this parcel that must be properly abandoned. Abandon with the assistance of a Certified Well Driller. Proposed infrastructure does not appear to violate setbacks to any surrounding properties well heads. 2. Site plan reflects connection to public sewer. Records reflect there was a septic tank and drain field on this parcel. Septic tanks shall be pumped, crushed and filled for proper abandonment. Owner to investigate if a septic tank still exists on property. Proposed infrastructure does not violate setbacks to any surrounding septic systems. NHC Addressing, McCabe Watson 910-798-7068 Street naming and property address 1. Existing address of 5012 Carolina Beach Road is acceptable for use. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 Public water and sewer 1. CFPUA TRC Comments provided are preliminary comments only. 2. CFPUA is moving toward becoming paperless. When ready to submit plan review package, upload all documents to https://www.cfpua.org/FormCenter/Engineering-3/Engineering- Plan-Review-103. 3. CFPUA water and sewer available. 4. Capacity is dependent on the analysis of the pipe collection system (gravity and force mains). 5. A capacity determination can be provided upon submittal of the NC DWQ FTA/FTSE Application Form and a Preliminary Plan, this determination does not guarantee capacity. 6. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the Authority. NCDOT, Nick Drees 910-343-3915 Driveway access and state road improvements 1. Please see attached. Contractor Office – 5012 Carolina Beach Road – TRC Review Page | 6 WMPO, Luke Hutson 910-343-3915 New Hanover County contracted traffic engineering services comments: 1. Please see attached. Army Corps of Engineers, Brad Shaver 910-251-4611 Information or Requirements if wetlands are impacted 1. Comments forthcoming. Project information also provided to the following state agencies and non-regulatory local agencies for their awareness: New Hanover County Emergency Management New Hanover County Schools NC Department of Environmental Quality (DEQ) NC DEQ Division of Coastal Management NC DEQ Division of Energy, Mineral, and Land Resources NHC Sustainability Manager, Madelyn Wampler STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION JOSH STEIN DANIEL H. JOHNSON GOVERNOR SECRETARY Mailing Address: NC DEPARTMENT OF TRANSPORTATION DIVISION OF HIGHWAYS 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 04-11-03 COURIER Telephone: 910-398-9100 Customer Service: 1-877-368-4968 Website: ncdot.gov Location: 5911 OLEANDER DRIVE, SUITE 101 WILMINGTON, NC 28403 Memorandum DATE: November 24, 2025 TO: New Hanover County Technical Review Committee SUBJECT: Jems Holdings – 5012 Carolina Beach Road ________________________________________________________________________ These are preliminary comments and are based on the plans as submitted for the proposed site. They are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. General Comments: NCDOT Driveway Permits, and Encroachments are submitted through the NCDOT Online Portal.https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx You can coordinate with the District Office with any questions 910-398-9100. NCDOT Driveway Permit: An NCDOT Driveway permit has been submitted to NCDOT for review. • Permit # D033-065-25-00174. This permit has yet to be assigned to a reviewer. NCDOT Encroachment Agreement: An NCDOT Encroachment Agreement is required for any utility connections or installations within the NCDOT right-of-way (form 16.6). • Refer to the NCDOT UAM Manual and the NCDOT encroachment checklist for required documents and site plan information. An NCDOT Encroachment Agreement is required for any sidewalk or multi-use paths installed within the NCDOT right-of-way (form 16.6). Site Plan Comments: Review comments will be sent through the NCDOT driveway permit portal. CAROLINA BEACH ROAD - U.S. HIGHWAY 421 (160' PUBLIC R/W) ANWAR RAYYAN and wifeSHAR RIAD RAYYAN THEODORE HEWLETTSR. TRUSTEE RO B E R T R O S A C K E T A L R0 7 1 1 7 - 0 0 3 - 0 0 2 - 0 0 0 D.B . 5 8 6 8 P G . 2 3 5 2 ANWAR RAYYAN ALYSON D. ABERNATHY R07100-001-005-000D.B. 5730 PG. 8 GAW RO B E R T R O S A C K E T A L R 0 7 1 1 7 - 0 0 3 - 0 0 1 - 0 0 0 D.B . 5 8 6 8 P G . 2 3 5 2 JAMES W. FREEMANand wifeNANCY E. FREEMAN BELLSOUTH TELECOMMUNICATION INC. R07117-003-009-000D.B. 1584 PG. 1492 C. FRED ALTMAN and wife LYNDA ALTMAN R07117-003-010-000D.B. 851 PG. 241ZONE: R-15USE: RESIDENCE PP PP PPT X X X X PP DITCH EX. 18" RCP D.I.T.R. 18.37'I.E. 15.46' WO O D F E N C E #5010 #5016 19 19 19 19 16 1618 17 18 19 17 1 6 15 15 13 12 14 14 17 16 DB 6332 PG 1559LOTS 5-7 PART LOTS 4 & 8BLOCK 1 SECTION ASILVER LAKE SUBDIVISIONMAP BOOK 76 PAGE 149PID: R07117-003-006-000 ZONE: B-2USE: COMMERCIAL DB 5850 PG 34TRACT 2SILVER LAKE SUBDIVISIONPART OF AREA BBLOCK 1 SECTION AMAP BOOK 4 PAGE 106-107PID: R07117-003-008-000ZONE: B-2USE: VACANT DB 5850 PG 34TRACT 1SILVER LAKE SUBDIVISIONLOTS 1-4BLOCK 1 SECTION AMAP BOOK 4 PAGE 106-107PID: R07117-003-007-000 DB 1823 PG 1152TRACT ONESILVER LAKE SUBDIVISIONPART OF AREA BBLOCK 1 SECTION AMAP BOOK 4 PAGE 106-107PID: R07117-003-004-000ZONE: B-2USE: VACANT DB 1823 PG 1152TRACT TWOSILVER LAKE SUBDIVISIONLOTS 12-14BLOCK 1 SECTION AMAP BOOK 4 PAGE 106-107PID: R07117-003-003-000ZONE: B-2USE: RESIDENCE JAMES W. FREEMAN andwife NANCY E. FREEMAN 17 15 14 14 16 15 17 GRAVEL DRIVEWAY(NO CULVERT)GRAVELDRIVEWAY FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOSUSPECTED FIBER OPTIC LINE (ESTIMATED LOCATION ±) 18 18 18 CO S.S.M.H.T.R. 19.11'IN 8" PVC 14.61'OUT 8" PVC 14.60' 24" PINE 30" PINE 36" PINE 25" PINE PR O P . B U I L D I N G 4, 0 0 0 S . F . 10' BUFFER 10 ' B U F F E R 5' SIDEWALK 5' SIDEWALK 3 24' 24 ' 15 ' 2 10' R25'R25 ' 18" RCP 30 ' S I D E S E T B A C K 35' REAR SETBACK 25' FRONT SETBACK/STREETYARD 16' DI #1RIM: 18.5INV: 15.27 I.E. 15.27' 18" PPES #2INV: 15.5 9' 18 ' 6 BOLLARDS 22 ' 18 ' (T Y P ) 9'(TYP) 10' EX. SS SERVICE(SEE UTILITY NOTE #1) CURB AND GUTTER CURB AND GUTTER NO CURBING 200 sf300 sf 295 sf 165 sf R25' (TY P ) 24' 220 sf 230 sf TAPER CURB TO FLAT ADA PARKING SIGN S.S.M.H.T.R. 19.16'IN 8" PVC 14.57'OUT 8" PVC 14.61 ASPHALT DRIVEWAY APRON 13.9'27.6' C-1 2 1" = 20' DEVELOPMENT NOTES:1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY LANDDEVELOPMENT CODE.2. PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS.3. NO SIGNS ARE PROPOSED AT THIS TIME. ANY FUTURE SIGNAGE IS REQUIRED A SEPARATE SIGNPERMIT FROM NEW HANOVER COUNTY. FIRE & SAFETY NOTES:1. BUILDING WILL NOT BE SPRINKLED2. CONTRACTOR SHALL MAINTAIN AN ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALLTIMES DURING CONSTRUCTION.3. BUILDING INFORMATION SIGNS MUST BE PROVIDED IN ACCORDANCE WITH THE "2018 NC FIRE CODEAPPENDIX J" REQUIREMENTS.4.CONTRACTOR SHALL SUBMIT A RADIO SIGNAL STRENGTH STUDY FOR ALL COMMERCIALBUILDINGS THAT DEMONSTRATES THAT EXISTING EMERGENCY RESPONDER RADIO SIGNALLEVELS MEET THE REQUIREMENTS OF SECTION 510 OF THE 2018 NC FIRE CODE. PR E L I M I N A R Y S I T E P L A N UTILITY NOTES:1. EXISTING CFPUA SANITARY SEWER SERVICE TO BE UTILIZED. CONTRACTOR TO VERIFY CONDITIONAND SIZE PRIOR TO START OF CONSTRUCTION. IF FOUND TO BE INADEQUATE IT SHOULD BEREPLACED AS REQUIRED BY CFPUA.2. WATER SERVICE TO BE PROVIDED VIA PRIVATE ON-SITE WELL, TO BE DESIGNED AND PERMITTED BYOTHERS.3. ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS & TELEPHONE SHALL BEINSTALLED UNDERGROUND.4. ALL SEWER UTILITIES TO BE INSTALLED PER CFPUA SPECIFICATIONS & STANDARDS.5.THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIESDURING CONSTRUCTION. CALL NC811 AT 811 OR 1-800-632-4949. CONTRACTOR IS RESPONSIBLE FORTHE REPAIR AND REPLACEMENT OF ANY UTILITIES, CURB & GUTTER, PAVEMENT, ETC. THAT MAYBE BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIRED TO AT LEAST THEQUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM.6. ALL RUNOFF FROM IMPERVIOUS SURFACES TO BE DIRECTED TO PIPED STORM DRAIN SYSTEM.7. SOLID WASTE DISPOSAL BY ROLL OUT CARTS FOR CURBSIDE PICKUP. EN G I N E E R I N G , P L L C IN T R A C O A S T A L REVISIONS Wi l m i n g t o n , N o r t h C a r o l i n a 2 8 4 0 3 57 2 5 O l e a n d e r D r . U n i t E - 7 Ph o n e : 9 1 0 . 8 5 9 . 8 9 8 3 PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): Em a i l : C h a r l i e @ i n t r a c o a s t a l e n g i n e e r i n g . c o m 2025-020 FO R CLIENT INFORMATION: OF 3 JAE CDC CDC 24x36 10/31/2025 Lic e n s e N u m b e r : P - 0 6 6 2 NE W H A N O V E R C O U N T Y , N C 50 1 2 C A R O L I N A B E A C H RD . JEMS Holdings, LLCJonathan Earle773 S. Kerr AveWilmington, NC 28403910-833-2147 PREL I M I N A R Y DRAW I N G D O N O T U S E FOR C O N S T R U C T I O N SILVE R L A K E R D SHAD E T R E E L N SAND L A P P E R L N C A R O L I N A B E A C H R D . - U . S . H W Y . 4 2 1 RAYE D R HORN R D SITE SITE DATA PARCEL ID: R07117-003-005-000 & R07117-003-005-001 CURRENT ZONING: B-2 PROJECT ADDRESS: 5012 CAROLINA BEACH RDWILMINGTON NC, 28412 CURRENT OWNER: JEMS HOLDINGS LLC 773 S. KERR AVE.WILMINGTON, NC 28403 TOTAL ACREAGE IN PROJECT BOUNDARY 21,441 S.F. (0.49 ac.) PROPOSED USE: CONTRACTORS OFFICE AND STORAGE BUILDING SIZE: 4,000 S.F. BUILDING HEIGHT: 1-STORY/±25' CALCULATION FOR BUILDING COVERAGE:PROPOSED COVERAGE 4,000 S.F. ÷ 21,441 S.F. = 18.7% BUILDING SETBACKS: FRONT: REQUIRED= 25' PROPOSED= 91.5'SIDE: REQUIRED= 30'L/0'R PROPOSED= 35'L/12.5'RREAR: REQUIRED= 35' PROPOSED= 53' PROPOSED IMPERVIOUS AREAS:BUILDINGS 4,000 S.F.ASPHALT PARKING AREA 8,970 S.F.CONCRETE SIDEWALK, C&G, ETC. 895 S.F.TOTAL 13,865 S.F (64.7%)*7,576 S.F. NET DECREASE*PARKING REQUIRED:CONTRACTOR OFFICE USE: (3/1,000 sf)1,200 SF/1,000*3 = 4 SPACES WAREHOUSE USE *less than 20,000 sf: (1.5/1,000 sf)2,800 SF/1,000*1.5 = 4 SPACES PARKING PROVIDED: 11 SPACES (1 ADA) PARKING LOT INTERIOR LANDSCAPINGREQUIRED 8,970 S.F. * 8% 718 S.F.PROVIDED 1,410 S.F. FOUNDATION PLANTINGS: FRONT FACADE: 40 LF X 15' FACADE X 12%REQUIRED: 72 S.F.PROVIDED: 85 S.F. REAR FACADE:REQUIRED: N/A (PARKING IN REAR AND NOT VISIBLE FROM R/W) STREETYARD: (25 S.F./LF FRONTAGE. 12.5' MIN./37.5' MAX. WIDTHS)FRONTAGE 88 LF - 24 LF DRIVEWAYS = 64 LF FRONTAGEREQUIRED: 25' X 64 LF 1,600 S.F.PROVIDED: 1,630 S.F. EXISTING SEWER AND WATER DEMAND: 0 GPD PROPOSED SEWER AND WATER DEMAND: 125 GPD ESTIMATED TRIP GENERATION (Per Trip Generation Manual 11th Edition):4,000 SF SPECIALTY TRADE CONTRACTOR (ITE CODE 180)AM PEAK: 7 PM PEAK: 8 DAILY: 39 40'20'10'20'0' Scale: 1"=20' PROPERTY LINERIGHT OF WAYADJOINERSEXISTING EDGE OF PAVEMENTEASEMENT EXISTING FIRE HYDRANT RUNOFF DIRECTION PROPOSED SPOT ELEVATION PARKING LOT INT. LANDSCAPING FOUNDATION PLANTINGS STREETYARD LANDSCAPING LEGEND 34.55 MEMORANDUM To: New Hanover County Technical Review Committee Date: November 21, 2025 Subject: 5012 Carolina Beach Rd – Redevelopment Office NCDOT Projects: • N/A WMPO 2050 MTP Projects: • N/A New Hanover County Projects: • N/A TIA: Based on the 11th edition ITE Trip Generation Manual, a TIA is not required. Land Use (ITE Code) Intensity Unit 24 Hour Volumes AM Peak Hour Trips PM Peak Hour Trips Specialty Trade Contractor (180) 4000 SF 39 7 8