HomeMy WebLinkAboutS25-05 BOC Staff ReportS25-05 Staff Report – Board of Commissioners 1-20-2026 Page 1 of 15
STAFF SUMMARY FOR S25-05
SPECIAL USE PERMIT APPLICATION
APPLICATION SUMMARY
Case Number: S25-05
Requests:
S25-5 – R-15 Campground / Recreational Vehicle (RV) Park
Applicant: Property Owner(s):
Jonathon Washburn
Joseph Burke Freedland with HBD Partners;
Dorothy Freedland with Market Street
Partners, LLC
Location: Acreage:
8600 block of Stephens Church Road 27.32
PID(s): Comp Plan Place Type:
R02900-001-009-000, R02900-001-008-000,
R02900-001-070-000, R02800-001-162-001 Community Mixed Use
Existing Land Use: Proposed Land Uses:
Vacant land with partial road infrastructure Campground/Recreational Vehicle (RV) Park
Current Zoning:
R-15, Residential
SURROUNDING AREA
LAND USE ZONING
North Wooded, residentially zoned land R-15
East Stephens Pointe Apartments CZD O&I
South Market Street and I-140 Highway
West DOT owned land, and wooded, residentially zoned land R-15
S25-05 Staff Report – Board of Commissioners 1-20-2026 Page 2 of 15
ZONING HISTORY
July 7, 1972 Initially zoned R-15 (8B)
COMMUNITY SERVICES
Water/Sewer Public water and sewer are available through CFPUA.
Fire Protection New Hanover County Fire Services, New Hanover County Porters Neck
District, New Hanover County Station 14.
Recreation Pages Creek Preserve, Ogden Park
CONSERVATION, HISTORIC, & ARCHAEOLOGICAL RESOURCES
Conservation
The conservation resource map indicates there may be pocosin and savannah
conservation resources on the site. Approximately 4.8 acres of the pocosin
resources are underlaid with Class IV soils. The trigger for additional
conservation standards is 5 acres. Additional field verification by the applicant
during the TRC review process will be required to determine if additional
standards may apply to the site. The conservation resources map indicates
approximately 2.5 acres of savannah conservation resources may exist on site
which is below the 5-acre minimum threshold that would trigger the
additional ordinance requirements.
Historic No known historic resources
Archaeological No known archaeological resources
S25-05 Staff Report – Board of Commissioners 1-20-2026 Page 3 of 15
APPLICANT’S PROPOSED PLANS
Site Plan with Staff Markup
The project features a one-way loop road with a separate entrance and exit onto Stephens
Church Road with a sewage dumping station located on a pull-off near the exit.
Located off the loop road will be a maximum of eighty-nine (89) designated RV sites, an
amenity building, pool, and manager’s office with associated parking on approximately 27.32
acres. Uses are limited to RV camping and associated recreational and amenity uses to serve
the RV campers. Other uses intended for individuals that are not temporarily staying at the RV
park are not under consideration and would require separate review and approval.
In addition to the 0.45 acres of designated open space, there is an existing pond intended to
provide recreational opportunities as well as stormwater management for the site.
During the preliminary forum the applicant indicated the stormwater pond might be used for
swimming in addition to canoeing, fishing or other water-based recreational activities. New
Hanover County Environmental Health and the Engineering Department have stated that
stormwater control measures such as wet ponds are not suitable for swimming due to
potential health and safety hazards. Stormwater control measures are engineered to manage
I-140 ramp
Amenity
building
and parking
Protected
Wetlands
Existing Pond &
Proposed
Stormwater
Pool
Manager’s
Office
Protected
Wetlands
20’ Transitional Buffer
N 50’ Existing
Tree Retention
Buffer
Open Space
Sewage
Dumping
Station
S25-05 Staff Report – Board of Commissioners 1-20-2026 Page 4 of 15
flood control and filter pollutants from urban runoff, making the unsuitable for human contact
because they collect runoff from roads, parking lots, and roofs which contain various
pollutants.
While the site contains approximately 5.64 acres of wetlands. The loop road and RV campsites
have been designed to minimize disturbance; however, about 0.11 acres of wetland impacts
are anticipated.
In addition to the Type A 20-foot-wide transitional buffer required adjacent to the residentially
zoned property along the northern and western boundaries, the applicant has included a
condition designating a 50-foot wide tree retention buffer along all property boundaries. The
50-foot tree retention buffer is intended to protect all trees located within 50 feet of the
property line to preserve the natural aesthetic and character of the RV park. No trees within
this buffer will be cut down.
ZONING CONSIDERATIONS
Campground/Recreational Vehicle (RV) Parks are permitted in the R-15 district with approval
of a Special Use Permit and are subject to the requirements in Section 4.3.4.E.2 of the UDO.
These standards generally address access, minimum dimensions, parking, structures, signage,
density, open space, and water and sewer.
Every RV Park shall have a minimum of 25 spaces, each with a designated minimum of 2,000
square feet per space for RV and passenger vehicle parking. The concept plan shows a
maximum 89 spaces, each a minimum of 2,000 square feet meeting the ordinance
requirement.
Required sanitary facilities have been provided on the site plan.
Campground/RV Parks require a minimum of 0.25 acres of open space for every 50
camping/RV sites. The applicant’s concept plan reflects 89 spaces, and 0.45 acres of open
space is provided on the concept plan, sufficiently meeting ordinance requirements.
Additionally, the wetlands and the pond will also be open, which accounts for another 5.64
and 3.88 acres respectively for a total of 9.97 acres of open space. This is approximately 9.5
acres above what is required by the ordinance.
The proposed 20-foot-wide paved road meets the requirements for an all-weather road, a
minimum of 12-feet wide with a minimum 20-foot-wide right-of-way required by the
ordinance.
Section 4.3.4.E.2.f states all spaces shall be located on sites with elevations that are not
susceptible to flooding. The subject parcel is not within a Special Flood Hazard Area or within
a non-regulatory Advisory Flood Hazard Area. While there are approximately 5.64 acres of
wetlands on site, the RV campsite spaces are shown outside of those wetland areas.
Section 4.3.4.E.2.k states that when RV campgrounds have more than one direct access onto
a public road, they shall not be less than 300 feet apart or closer than 300 feet to a public road
intersection. While the site provides two driveway connections to Stephens Church Road less
than 300 feet apart, the concept plan indicates one is for ingress and the other is for egress
only. While not specifically listed as a condition, if approved, the inclusion of the access
limitation on the concept plan can be enforced as a condition of the concept plan.
S25-05 Staff Report – Board of Commissioners 1-20-2026 Page 5 of 15
Section 4.3.4.E.2.u requires the RV Park to maintain a register book; however, it does not
stipulate a limit on how long people can stay.
If approved, the project would be subject to the Technical Review Committee and Zoning
Compliance review processes to ensure full compliance with all ordinance requirements and
specific conditions included in the approval. Only minor deviations from the approved
conceptual plan, as defined by the UDO, would be allowed.
AREA DEVELOPMENT
S25-05 Staff Report – Board of Commissioners 1-20-2026 Page 6 of 15
TRANSPORTATION
CURRENT CONDITIONS
Intensity of Current Zoning Typical development under current zoning would allow a
maximum of 108 single-family dwelling units.
PROPOSED ACCESS
Primary Access Full access onto Stephens Church Road
EXISTING ROADWAY CHARACTERISTICS
Affected Roadway Stephens Church Road Market Street
Type of Roadway Local Principal Arterial
S25-05 Staff Report – Board of Commissioners 1-20-2026 Page 7 of 15
Roadway Planning Capacity
(AADT) N/A 20,684.16
Latest Traffic Volume (AADT) -
2023 N/A 46,500
Latest WMPO Point-in-Time
Count (DT) N/A 50,123
Current Level of Congestion N/A Over Capacity
Sources
Source of Planning Capacity: WMPO
Source of Latest Traffic Volume: 2023
Source of WMPO Point-in-Time Count: 2024
TRAFFIC GENERATION
Traffic Generation
by Present
Designation
Traffic Generated
by Proposed
Project
Potential Impact
of Proposed
Project
AM Peak Hour Trips 35 19 -16
PM Peak Hour Trips 43 24 -19
Assumptions
Typical Development with Existing Zoning – 79 single family
dwelling units.
Proposed Development – 89 campsites
Sources
Source of Trip Generation: ITE Trip Generation Manual, 11th ed
TRAFFIC IMPACT ANALYSIS (TIA)
The site’s projected traffic does not exceed the 100 peak-hour trips that triggers the ordinance
requirement for a Traffic Impact Analysis (TIA).
SUMMARY
The project is located on Stephens Church Road north of Market Street and the I-140 interchange.
Stephens Church Road is a local road which does not experience sufficient traffic volumes to trigger
regular measurement or assessment by NCDOT. The intersection of Stephens Church Road and Market
Street is a controlled traffic light allowing vehicles to travel north on Market Street to make a left to
access the site. The location of this site at the northern entrance to the County and proximity to the
interchange provides the opportunity to reduce larger RVs on the Market Street corridor while allowing
those staying at the site to access other areas of the county. While below the threshold for a TIA, the
site will require review through DOT’s driveway permit process.
S25-05 Staff Report – Board of Commissioners 1-20-2026 Page 8 of 15
ENVIRONMENTAL
The property is not within a Natural Heritage Area or the Special Flood Hazard Area.
The property is within the Pages Creek watershed.
Per the Classification of Soils in New Hanover County for Septic Tank Suitability, soils on the
property consist of Class I (Suitable), Class III (Severe Limitation), and Class IV (Unsuitable) soils;
however, the project is expected to be served by CFPUA water and sewer if developed.
The conservation resource map indicates there may be pocosin and savannah conservation
resources on the site. Approximately 4.8 acres of the pocosin resources are underlaid with
Class IV soils. The trigger for additional conservation standards is 5 acres. Additional field
verification by the applicant during the TRC review process will be required to determine if
additional standards may apply to the site. The conservation resources map indicates
approximately 2.5 acres of savannah conservation resources may exist on site which is below
the 5-acre minimum threshold that would trigger the additional ordinance requirements.
OTHER CONSIDERATIONS
Context and Compatibility
The property is located off of Market Street, as one would enter the County coming from the
north. It is adjacent to the Market St (USHWY 17) right-of-way and the I-140 right-of-way as
well as undeveloped R-15 residential land to the west. Just to the north is an apartment
complex.
The proposed Campground/RV Park acts as an appropriate transition between the highway
corridors and the existing lower density residential development to the west, especially with
the addition of the tree retention buffer.
The property is located just north of the Porter’s Neck commercial node providing services,
amenities, and recreational opportunities.
Most of the surrounding land is either single-family residential, multi-family residential, or
commercial uses intended to serve the surrounding homes.
S25-05 Staff Report – Board of Commissioners 1-20-2026 Page 9 of 15
2016 COMPREHENSIVE LAND USE PLAN
The New Hanover County Future Land Use Map provides a general representation of the vision for
New Hanover County’s future land use, as designated by place types describing the character and
function of the different types of development that make up the community. These place types are
intended to identify general areas for particular development patterns and should not be interpreted
as being parcel specific.
Future Land Use
Map Place Type Community Mixed Use
Place Type
Description
Community Mixed Use: Focuses on small-scale, compact, mixed use
development patterns that serve all modes of travel and act as an attractor
for county residents and visitors. Types of appropriate use include office,
retail, mixed use, recreational, commercial, institutional, multi-family and
single-family residential.
Analysis
The 2016 Comprehensive Plan classifies the property as Community Mixed
Use which encourages mixed use development patterns, including
recreational uses, that attract county visitors.
The proposed project location will serve visitors as they enter the County in
their RVs, allowing them to stop without driving farther down Market Street.
From this site, the I-140 ramp and Market Street provide access to the area’s
attractions and activities including the Porter’s Neck commercial node.
Situated at the intersection of I-140 and Market Street, the site also provides
an appropriate transition to the single-family residential area located to the
west.
Proposed Conditions
1. Site to retain undisturbed tree save area within the area labeled as a 50-foot-wide existing tree
retention buffer along all property lines as shown on the site plan.
S25-05 Staff Report – Board of Commissioners 1-20-2026 Page 10 of 15
EXAMPLE MOTION
Staff does not provide a recommendation for Special Use Permits; however, staff has compiled
information to assist the Board in their decision making to determine the appropriate Findings of Fact
to Date.
Based on the evidence presented to the Board, one of the following motions could be made:
Example Motion for Approval:
Motion to approve the permit as the Board finds that this application for a Special
Use Permit meets the four required conclusions based on the findings of fact
included in the Staff Report and additional evidence presented at the public
hearing.
OPTIONAL (if conditions have been identified that will bring the proposal in line with
the required conclusions.)
Subject to the following conditions agreed to by the applicant:
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
Example Motion for Denial:
Motion to deny the permit because the Board cannot find (choose all that apply):
a. That the use will not materially endanger the public health or safety if located
where proposed (for the following reason(s)):
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
b. That the use meets all required condition and specifications (for the following
reason(s)):
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
c. That the use will not substantially injure the value of adjoining or abutting
property, or that the use is a public necessity (for the following reason(s)):
S25-05 Staff Report – Board of Commissioners 1-20-2026 Page 11 of 15
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
d. That the location and character of the use if developed according to the plan
as submitted and approved will be in harmony with the area in which it is to
be located and in general conformity with the Comprehensive Land Use Plan
for New Hanover County (for the following reason(s)):
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
STAFF PRELIMINARY CONCLUSIONS AND FINDINGS OF FACT
After an analysis of the proposed use and the information provided as part of the application package
staff has compiled the facts provided in the application and identified through staff technical review
and analysis. They are organized by the applicable conclusion. These findings are preliminary and
additional relevant facts may be presented during the public hearing. Compiled facts may or may not
support the Board’s conclusion.
Conclusion 1: The Board must find that the use will not materially endanger the public health
or safety where proposed and developed according to the plan as submitted and approved.
Compiled Facts May or May Not Support the Board’s Conclusion.
Relevant Findings of Fact Presented to Date
A. CFPUA water and sewer are available. Concept plan states project shall install water and
sewer services to in accordance with CFPUA standard details and specifications.
B. The subject property is located in the New Hanover County Porter’s Neck Fire Service
District.
C. The project includes direct access onto Stephens Church Road which is located off Market
Street.
D. The AADT Planning Capacity for Stephens Church Road is not available. The AADT Planning
Capacity for Market Street is 20,684 and the Latest Traffic Volume is 46,500 trips indicating it
is over capacity.
E. The site’s projected traffic does not exceed the 100 peak-hour trips that triggers the
ordinance requirement for a Traffic Impact Analysis (TIA).
F. The closest county parks are Ogden Park and Pages Creek Preserve.
G. The conservation resource map indicates pocosin wetlands on the property however they
are only underlaid with approximately 2.5 acres of Class IV soils, therefore no additional
development standards are required.
S25-05 Staff Report – Board of Commissioners 1-20-2026 Page 12 of 15
H. New Hanover County Environmental Health and the Engineering Department have stated
that stormwater control measures such as wet ponds are not suitable for swimming due to
potential health and safety hazards. Stormwater control measures are engineered to
manage flood control and filter pollutants from urban runoff, making the unsuitable for
human contact because they collect runoff from roads, parking lots, and roofs which contain
various pollutants.
Conclusion 2: The Board must find that the use meets all required conditions and
specifications of the Unified Development Ordinance.
Compiled Facts May or May Not Support the Board’s Conclusion.
Relevant Findings of Fact Presented to Date
A. Campground/Recreational Vehicle (RV) Park is allowed by Special Use Permit in the R-15,
Residential zoning district.
B. Setbacks for the R-15 district are as follows: front setback is 25 feet, side setback (street) is
15 feet, side setback (interior) is 10 feet, and the rear setback is 20 feet. All setbacks are
reduced to 0 feet when in a Performance Residential Development, with the exception that
buildings on the periphery of a Performance Residential Development be set back a
minimum of 20 feet from the adjoining property line.
C. Section 3.2.8.D states the maximum building height in the R-15 district is 40 feet. Structures
elevated on open foundations consisting of piers, posts, columns or piles shall have a
maximum height of 44 feet
D. Section 4.3.4.E.2.a states there must be a minimum of 25 spaces. The concept plan shows
an 89 spaces, which meets the required minimum number of spaces outlined in the
ordinance.
E. Section 4.3.4.E.2.b states that Recreational vehicles and travel trailers shall only be occupied
in approved campgrounds.
F. Section 4.3.4.E.2.c states that every space shall consist of a minimum area of 2,000 square
feet and each space shall be designated on the ground by permanent markers or
monuments. The concept plan shows all spaces have 2,000 square feet.
G. Section 4.3.4.E.2.d states that parking spaces sufficient to accommodate at least one motor
and camping vehicle shall be constructed within each space. The concept plan shows the
area designated for each camping space can accommodate one motor and camping vehicle.
H. Section 4.3.4.E.2.e states that all spaces developed adjacent to a public street shall be set
back a minimum of 40 feet from the street right-of-way. The concept plan shows all spaces
near a public right-of-way will be set back a minimum of 40 feet.
I. Section 4.3.4.E.2.f states that all spaces shall be located on sites with elevations that are not
susceptible to flooding. The spaces shall be graded to prevent any water from ponding or
accumulating within the park. Each space shall be properly graded to obtain a reasonably
flat site and to provide adequate drainage away from the space. The site is not located
within a Special Flood Hazard Area.
J. Section 4.3.4.E.2.g states that the park shall have all weather roads that directly abut each
space. All road rights-of-way shall be 20 feet except that one-way roads may have a
S25-05 Staff Report – Board of Commissioners 1-20-2026 Page 13 of 15
minimum width of 12 feet. In areas of heavy traffic use, 30-foot rights-of-way shall be
required. The concept plan shows all one-way roads as paved and 20 feet in width.
K. Section 4.3.4.E.2.h states that no space shall have direct vehicular access to a public road.
The concept plan shows no spaces with direct access to public roads.
L. Section 4.3.4.E.2.i states that the park shall be developed with proper drainage ditches. All
banks shall be sloped and seeded.
M. Section 4.3.4.E.2.j states that cul-de-sacs or dead-end roads shall not exceed 1,000 feet in
length measured from the entrance to the center of the turnaround. Any road designed to
be permanently closed shall have a turnaround at the closed end with a minimum right-of-
way diameter of 80 feet.
N. Section 4.3.4.E.2.k states that when the park has more than one direct access to a public
road, they shall not be less than 300 feet apart or closer than 300 feet to a public road
intersection unless unusual site conditions demand otherwise.
O. Section 4.3.4.E.2.l states that each park shall have a central structure or structures that will
provide separate toilet facilities for both sexes. This structure may also contain a retail sales
counter and/or coin operated machine for the park residents’ use only, provided there is no
exterior advertising. Vending machines also may be permitted in a sheltered area.
P. Section 4.3.4.E.2.m states that no swimming pool or bathing area shall be installed, altered,
improved, or used without compliance with applicable Health department regulations. No
bathing area shall be used without the approval of the New Hanover County Health
Department.
Q. Section 4.3.4.E.2.n states that sanitary facilities shall be provided in accordance with the
following standards: all toilet, shower, lavatory, and laundry facilities shall be provided and
maintained in a clean and sanitary condition and kept in good repair at all times, they shall
be safely and adequately lighted, facilities shall be easily accessible and conveniently located,
all toilet, shower, lavatory, and laundry room facilities shall be acceptable to the New
Hanover County Health department and shall be inconformity with all New Hanover County
codes, and all buildings shall be constructed in accordance with the building codes for the
county.
R. Section 4.3.4.E.2.o states that water supply shall comply with the following standards: a safe,
adequate, and conveniently located water supply must be provided for each park, and no
water supply shall be installed, altered, or used without the approval of the New Hanover
County Health Department. The applicant intends to connect to CFPUA for water and sewer.
S. Section 4.3.4.E.2.p states that sewage disposal shall comply with the following standards:
sewage dumping stations shall be approved by the New Hanover County Health
Department, each park shall provide at least one sewage dumping station, no method of
sewage disposal shall be installed, altered, or used without the approval of the New Hanover
County Health department, and all sewage wastes from each park, including wastes from
toilets, showers, bathtubs, lavatories, wash basins, sinks, and water using appliances not
herein mentioned, shall be piped into the park’s sewage disposal system or systems. The
concept plan shows a dumping station.
T. Section 4.3.4.E.2.q states that open space shall be provided in accordance with the following
standards: each park shall provide open space areas to serve the needs of the anticipated
users, a minimum of 0.25 acres of level, well-drained ground for every 50 spaces shall be
S25-05 Staff Report – Board of Commissioners 1-20-2026 Page 14 of 15
required as open space, and the park owner is responsible for the development and
maintenance of all open space areas. The concept plan shows adequate open space has
been provided.
U. Section 4.3.4.E.2.r states that fire hydrants shall be provided in accordance with the following
standards: the developer of any campground or recreational vehicle park with a central
water system meeting State requirements for fire hydrants shall be responsible for providing
adequate fire protection for the park through the provision of a fire hydrant located as close
as possible to the entrance of the park, and the hydrant shall be connected to the central
water system serving the park and in accordance with specification established by the
County Fire Marshal.
V. Section 4.3.4.E.2.s states that the park owner is responsible for refuse collection.
W. Section 4.3.4.E.2.t states that it shall be unlawful for a person to park or store a mobile home
in a campground or recreational vehicle park. However, one mobile home may be allowed
within a park to be used as an office and/or residence of persons responsible for the
operation and maintenance of the travel trailer park.
X. Section 4.3.4.E.2.u states that it shall be the duty of the operator of the campground or
recreational vehicle park to keep an accurate register containing a record of all occupants of
the park. The owner shall keep the register available at all times for inspection by law
enforcement officials, public health officials, and other officials whose duties necessitate
acquisition of the information contained in the register. The register shall contain the
following information: name and address of the occupants of each space, date entering and
leaving the park, and the license number of each vehicle (car, truck, camping vehicle, etc.)
with state of issuance, make, and type of equipment.
Conclusion 3: The Board must find that the use will not substantially injure the value of
adjoining or abutting property or that the use is a public necessity.
Compiled Facts May or May Not Support the Board’s Conclusion.
Relevant Findings of Fact Presented to Date
A. The proposed RV Park is on vacant property.
B. Land uses in the immediate vicinity of the subject site are vacant land, single family
residential, multi-family residential, NCDOT roadway, and mixed commercial along Market
Street.
C. No evidence has been submitted regarding the impact this project will have on the adjoining
or abutting property.
D. No contradictory evidence has been submitted that this project will substantially injure the
value of adjoining or abutting properties.
Conclusion 4: The Board must find that the location and character of the use if developed
according to the plan as submitted and approved will be in harmony with the area in which it
is to be located and in general conformity with the Comprehensive Land Use Plan for New
Hanover County.
S25-05 Staff Report – Board of Commissioners 1-20-2026 Page 15 of 15
Compiled Facts May or May Not Support the Board’s Conclusion.
Relevant Findings of Fact Presented to Date
A. The subject site is currently undeveloped.
B. No known cultural or archaeological resources are identified on site.
C. The site is surrounded by Stephens Pointe Apartments to the east, wooded R-15 to the north
and west, and highway to the south.
D. Land uses in the immediate vicinity of the subject site are a mix of commercial and
residential.
E. The 2016 Comprehensive Plan classifies the properties as Community Mixed Use.