HomeMy WebLinkAboutPlan Set 81-903088078 28.5 1.0 28.0 5.5 9.5 10.0 11.0 11.4512 WETWELL DIAMETER (FT) 24" INFLUENT INV ELEV (FT) CAPACITY (GPM) T.D.H. (FT) MOTOR (HP) TOP OF STATION ELEV (FT) BOTTOM OF STATION ELEV (FT) FINISHED GRADE (FT) PUMP OFF ELEVATION (FT) LEAD PUMP ON ELEV (FT) LAG PUMP ON ELEV (FT) HIGH WATER ALARM ELEV (FT) SECTION SCALE: 1/4 " = 1'-0" 3 PS-2.1 PS-2.1 3 PUMP STATION SCHEDULE TOP OF WETWELL EL= 28.5 FINISHED GRADE EL = 28.0 21 7 PLAN SCALE: 1/4 " = 1'-0" 1 PS-2.1 50 1 1 5' M I N . 6" M I N . 12 " M I N . 12" MIN. 6" MIN. 12" 6" M I N . TOP OF VALVE VAULT EL=28.5 22 23 9 12 17 8 5 36 13 14 15 PLAN SCALE: 1/4 " = 1'-0" 2 PS-2.1 SECTION SCALE: 1/4 " = 1'-0" 4 PS-2.1 1.12'-0" I.D. PRECAST POLYMER CONCRETE WET WELL 2.TOP SLAB REINFORCEMENT, SEE STRUCTURAL SHEET S101. 3.48" x 84" ALUM DOUBLE DOOR 1/4" ALUM. DIAMOND PLATE ACCESS HATCH W/ SAFETY GRATE HINGES OPEN INDEPENDENTLY. 4.JIB CRANE FOUNDATION (SEE STRUCTURAL PLANS) 5.48" X 72 ALUM DOUBLE DOOR 1/4" ALUM. DIAMOND PLATE ACCESS HATCH W/ SAFETY GRATE, HINGE ON SOUTH SIDE. 6.5'-0" I.D. GRINDER MANHOLE (SEE DTL. PS-C.10/PS-3.2) 7.8" M.J. TO M.J. CONNECTOR 8.4" D.I. VENT PIPE W/ S.S. SCREEN 9.4" SCHEDULE 80 PVC DRAIN PIPE WITH P-TRAP, SLOPE TO WET WELL @ 1.0% 10.10" PVC GRAVITY SEWER PIPE 11.8" DUCTILE IRON FORCE MAIN 12.7'-0" x 8'-0" PRECAST CONCRETE VALVE VAULT 13.PRESSURE GAUGE INCLINED SO AS TO BE READ FROM SURFACE (TYP. OF 2) 14.8" CHECK VALVE 15.8" PLUG VALVE 16.8" 90° BEND (FL.) 17.8" x 8" TEE (FL) 18.PROVIDE LINK SEAL AT WALL PENETRATIONS FOR WATERTIGHT SEAL 19.5'-0" I.D. PRECAST POLYMER CONCRETE MANHOLE 20.JIB CRANE, MAX. CAPACITY 4000 LBS. W/ X' REACH (SEE STRUCTURAL PLANS) 21.P-TRAP 22.FLOOR DRAIN W/ BACKWATER VALVE 23.12" NO. 57 STONE 24.S.S. HOOK 25.S.S. CABLE HOLDER 26.TERMINAL CABINET 27.8" D.I. FORCE MAIN RISER (FL x PE) 28.STAINLESS STEEL GUIDE RAIL 29.POWER CABLE 30.STAINLESS STEEL LIFTING CHAIN 31.CONDUIT FROM TERMINAL CABINET 32.PROVIDE 2" x 2" S.S. STRAP AND ANCHOR TO WALL @ 16" O.C. 33.DUPLEX SUBMERSIBLE PUMPS (SEE PUMP STATION SCHEDULE AND SPECIFICATIONS FOR REQUIREMENTS) 34.CONCRETE GROUT 35.LIFTING LUGS 36.1" CHAMFER ALL SIDES (TYP.) 37.VALVE BOX, TYP. 38.ALUMINUM VERTICAL LADDER, WALL MOUNTED, HALLIDAY, BILCO OR APPROVED EQUAL 39.WATERTIGHT MANHOLE RING AND COVER (SEE DETAIL, SHEET PS-3.1) 40.8" ELECTROMAGNETIC FLOW METER (FL) (SEE DETAIL PS-C4/PS-3.2) 41.2" AIR/VACUUM AIR VALVE (FL) (SEE DETAIL S7/PS-3.1) 42.8" BLIND FLANGE 43.BYPASS PUMPING CONNECTION (SEE DETAIL PS-C5/PS-3.2) 44.MANUFACTURER'S STANDARD SELF-SEALING PUMP BASE 45.2'-6" x 3'-0" SINGLE LEAF, 1/4" ALUM. DIAMOND PLATE ACCESS HATCH W/ SAFETY GRATE 46.8" x 8" WYE (MJ) 47.8" x 8" TEE (MJ) 48.8" x 12" REDUCER (MJ) 49.6" X 8" ECCENTRIC REDUCER 50.6'-0" X 8'-0" PRECAST CONCRETE VAULT 51.48" X 48" DOUBLE LEAF, 1/4" ALUM. DIAMOND PLATE ACCESS HATCH W/ SAFETY GRATE 52.8" FULL FLANGE ANNULAR PRESSURE SENSOR W/ COMPANION GAUGE 53.2'-0" X 2'-6" SINGLE LEAF, 1/4" ALUM DIAMOND PLATE ACCESS HATCH W/ SAFETY GRATE. ACCESS HATCH HINGES ON NORTH SIDE, SAFETY GRATE HINGES ON WEST SIDE. 54.8" STILLING WELL-SEE DETAIL 6/PS-3.3 55.RESTRAINED DISMANTLING JOINT PUMP STATION KEY TOP OF ARVMH EL = 28.5 19 39 38 41 FINISHED GRADE EL = 28.0 36 11 115' M I N . 12 " M I N . 23 22 37 37 9 19 18 38 41 39 22 11 10 45 37 11 8 12 16 5 18 151413 7'-0" 8" 18 7 27 LF OF 24" C900 PVC @ 1.00% 6" M I N . 6" MIN. 6" MIN. TOP OF MANHOLE EL= 28.5 6 23 24" INV OUT = 11.72 10" Inv In=13.22 40 50 18 11 11 SIZES OF CONCRETE OPENINGS TO BE VERIFIED BY THE CONTRACTOR BEFORE TOP SLAB CONSTRUCTION *** 45 464715 7 7 47 15 12" MIN. 6" MIN. PS-2.1 4 1 1 12" MIN. 12" MIN. 12 " M I N . 10 " M I N . 8" MIN. HIGH WATER ALARM LAG PUMP ON LEAD PUMP ON PUMP OFF 23 34 33 32 35 29 28 27 36 2 20 3 24 16 25 31 26 8 1 8" 4 3 1 8 C/ L O F WE T W E L L 2 10 17'-0" 12" MIN. NOTES: 1. ALL BOLTED CONNECTIONS SHALL BE MADE USING 304 S.S. BOLTS, WASHERS, AND NUTS. 2.CONTRACTOR SHALL VERIFY DIMENSION WITH PUMP AND VALVE MANUFACTURERS' DIMENSIONS. COORDINATE ACCESS HATCH DIMENSIONS TO ENSURE PROPER CLEARANCES. 3.INTERIOR CORROSION PROTECTION - THE INTERIOR SURFACE OF THE WET WELL, VALVE VAULTS AND AIR RELEASE MANHOLES ALONG THE SEWER FORCE MAIN SHALL BE THOROUGHLY CLEANED OF ALL OILS, LATENCE, DIRT, LOOSE CONCRETE , ETC. ALL VOIDS OR SURFACE BLEMISHES SHALL BE FILLED OR REPAIRED USING CALCIUM ALUMINATE (MORTAR). THE JOINTS OF PRECAST UNITS SHALL RECEIVE THREE (3) COATS OF MORTAR SO AS TO ACHIEVE A SMOOTH SURFACE AT EACH JOINT. AFTER THE INTERIOR PATCHING HAS THOROUGHLY DRIED, THE ENTIRE SURFACE OF THE STRUCTURE INTERIOR SHALL RECEIVE SPRAY-IN-LINER WITH A TOTAL DRY FILM THICKNESS OF 8 TO 12 MILS. NICKS AND SCRATCHES SHALL BE TOUCHED UP PRIOR TO ACCEPTANCE. IF MATERIAL OTHER THAN SHERWIN WILLIAMS SEWER -COTE OR SHER-FLEX IS PROPOSED, IT SHALL BE APPROVED BY THE ENGINEER PRIOR TO USE. 4.EXTERIOR JOINTS OF ALL PRECAST CONCRETE SHALL BE WRAPPED PER THE SPECIFICATIONS. 5.SHERWIN WILLIAMS SEWER-COTE OR SHER-FLEX APPLIED TO THE OUTSIDE OF ALL TONGUE AND GROOVE JOINTS. PRIOR TO BACKFILLING THE WET WELL STRUCTURE,. THE ENTIRE SURFACE SHALL RECEIVE ONE (1) COAT. THE MATERIAL USED FOR EXTERIOR COATING SHALL MEET THE REQUIREMENTS OF CORPS OF ENGINEERS SPECIFICATION C-200. THE EXTERIOR COATING SHALL BE APPLIED AS TO ACHIEVE A DRY FILM THICKNESS OF NOT LESS THAN 10.0 MILS. THE EXTERIOR SURFACE SHALL BE CLEAN AND DRY PRIOR TO APPLICATION OF THE COATING. 6.SEE SHT. PS-3.1 FOR CFPUA STANDARD DETAILS PS-C2 AND PS-C3. USE THE MORE STRINGENT DIMENSIONS BETWEEN THE STANDARD DETAILS AND THE DESIGN FOR CONSTRUCTION. 17 ' - 0 " 22 6 9 9 10 30 18 4' - 9 34" 3' - 6 " 49 11 8 2' - 0 " TOP OF FLOW METER VAULT EL = 28.5 51 38 40 50 36 115' M I N . 12 " M I N . 2322 46 12" MIN. 6" MIN. 22 15 15 38 1515 8'- 0 " 53 SENSOR No. 1 - PUMP OFF =5.5' 4 54 48 48 8" 8'-0" 6' - 0 " 51 1'- 6 " 3'- 0 " 33 33 26 26 8 7'-0" SUBMERSIBLE PUMP NOTES: 1.FOR THE DUPLEX SUBMERSIBLE PUMPS, THE INITIAL DUTY CONDITION OF 880 GPM @ 78' TDH AND BUILD-OUT DUTY CONDITION OF 1215 GPM @ 124.5' TDH SHOULD BE ACHIEVED BY UTILIZING THE SAME PUMPS WITH IMPELLER AND MOTOR (75 HP) UPSIZE. 44 26 38 18 17 18 18 55 4715 15 11 57 5' - 6 " 37 55 57 4" 10.5 HIGH WATER TELEMETRY ELEV (FT) HIGH WATER TELEMETRY 9 13 T: \ S t a n d a r d s \ C A D D \ C i v i l 3 D \ 0 1 _ T e m p l a t e s \ T W C - C I V L _ T i t l e b l o c k _ 2 4 x 3 6 . d w g LL O R S C H E I D E R 10 / 2 9 / 2 0 2 5 2 : 1 0 P M PU M P S T A T I O N - P L A N A N D S E C T I O N S BJPO EML NTD PS-2.1 PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 CFPUA GENERAL NOTES FROM PS-C3: 1.UNLESS OTHERWISE SPECIFIED, ALL METAL WET WELL COMPONENTS, HARDWARE, AND FASTENERS SHALL BE CAST IRON, DUCTILE IRON OR 316 STAINLESS STEEL OR BETTER. 2.UNLESS OTHERWISE SPECIFIED, ALL CONCRETE FASTENERS TO BE 316 STAINLESS STEEL WEDGE ANCHORS (TYP). 3.CONCRETE FILLET IN BOTTOM OF WET WELL TO START 10" FROM THE ULTIMATE PUMP SIZE AND BASE AT 45° (TYP) ALL AROUND. 4.ONE PIECE SCHEDULE 40, 316 STAINLESS STEEL GUIDE RAILS. DIAMETER PER MANUFACTURERS RECOMMENDATION. TWO PIECE RAILS WITH INTERMEDIATE (MID 1/3) SUPPORT, FOR LENGTHS GREATER THAN 18 FEET. UPPER GUIDE RAIL BRACKET SHALL ALSO BE STAINLESS STEEL. 5.PUMP REMOVABLE CHAIN AND RELATED LIFTING HARDWARE TO BE 3/8" MIN., 316-L STAINLESS STEEL 2000 LB MIN. WORKLOAD LIMIT. LENGTH TO EXTEND 4' ABOVE HATCH. 6.PUMP DISCHARGE SUPPORT BRACKET FOR DUCTILE IRON, OVER 10' MIN. ONE REQUIRED MIDWAY. 7.ACCESS HATCHES SHALL BE PAD LOCKABLE FRAME AND COVER, WITH 1/4" ALUMINUM PLATE AND 1/8" THICK X 3" WIDE STAINLESS STEEL HINGES MIN,. AND POSITIVE LOCKING DOOR RESTRAINT. HINGE ON DISCHARGE SIDE OF WET WELL AND VALVE BOX. (HALLIDAY PROD. OR EQUAL, SIZE AS REQUIRED) W/ SAFETY GRATE. 8.PLUG VALVES TO BE DEZURIK (FIG. 118) ECCENTRIC, CAST IRON BODY AWWA C504 WITH 4" HAND WHEEL AND NON RISING STEM. SWING CHECK VALVES SHALL BE AS SPECIFIED. 9.ELEVATION OF TOP OF WET WELL AND ELECTRICAL CONDUITS SHALL BE 2.0 FEET ABOVE THE 100 YEAR FLOOD ELEVATION. 10.CONCRETE PAD (36" MINIMUM WIDTH W/ 45° CHAMFER) AROUND OUTSIDE DIAMETER OF WET WELL. ITEM DESCRIPTION DIM. "A"OUTSIDE DIAMETER OF WET WELL 13'-4" "B"INSIDE DIAMETER OF WET WELL 12' "C"WET WELL ACCESS HATCH LENGTH 7' "D"WET WELL ACCESS HATCH WIDTH 4' "E"CL PUMP TO CL PUMP DIMENSION 3'-6" "F"CL HATCH TO OUTSIDE OF WET WELL 6'-6" "G"CL HATCH TO INSIDE OF WET WELL 6' "H"PIPE DIAMETER 8" "I"FLANGE TO FLANGE DIMENSION 2'-5" "J"VALVE VAULT LENGTH 8' "K"VALVE VAULT WIDTH 8' "L"VALVE VAULT ACCESS HATCH LENGTH 4' "M"VALVE VAULT ACCESS HATCH WIDTH 6' "N"INFLUENT PIPE SIZE 10" "O"FORCE MAIN PIPE SIZE 8" CFPUA TABLE FROM PS-C2 10/29/2025 SERIES L1B and L1D LADDERS · · · · · · · · · · · (ADVISE)(ADVISE) L1D (FLOOR AND WALL MOUNT)L1B (WALL MOUNT) HALLIDAY PRODUCTS SERIES L1E LADDER EXTENSION · · · · · · INSTALLATION & OPERATION INSTRUCTIONS Installation: A) Place ladder flat on the ground with standoffs up. B) Place 2" (52 mm) square aluminum tube in center of rungs with the "T" shaped slot below third rung as shown (Model A) or second rung (Model B). C) Place stainless steel channel clamp over square aluminum tube so "U" clamp holes line up on either side of rungs as shown. D) Insert stainless steel "U" bolts over rung and through holes in stainless steel channel clamp as shown. E) Apply 10-15 foot pounds (1.3-2.1 kg./meter) of torque to all "U" bolt nuts. F) Verify that square aluminum tube is secured to ladder rungs. Operation: A) To engage ladder extension, grasp aluminum post above the top stainless steel channel clamp, and pull straight up until lower stainless steel pin is seated. B) Rotate aluminum post 1/4 turn in either direction to secure pin in slot as shown in Detail. HALLIDAY PRODUCTS T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ P S - 2 . 0 P S T A T I O N . d w g LL O R S C H E I D E R 10 / 2 9 / 2 0 2 5 9 : 4 0 A M DE T A I L S PS-3.1 BJPO EML NTD PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 HOLLY SHELTER PUMP STATIONXXX HOLLY SHELTER RDCASTLE HAYNE NC 28429 IN CASE OF EMERGENCYCALL 910-332-6565NO TRESPASSING 24" 24 " ALUMINUM SIGN WITH 2" MINIMUM HEIGHT LETTERING. PAINT BACKGROUND BLUE. BORDER AND LETTERING WHITE. MOUNT SIGN TO FENCE W/ FOUR -3/4" x 1/8" SHEET METAL SCREWS. 1. NOTES: 2 PS-3.1 NO SCALE PUMP STATION PLACARD 3 PS-3.1 NO SCALE ALUMINUM VERTICAL LADDER 4 PS-3.1 NO SCALE ALUMINUM LADDER EXTENSION 10/29/2025 T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ P S - 2 . 0 P S T A T I O N . d w g LL O R S C H E I D E R 10 / 2 9 / 2 0 2 5 9 : 4 0 A M DE T A I L S PS-3.2 BJPO EML NTD PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 10/29/2025 4 NOT TO SCALE EMERGENCY SHOWER AND EYEWASH 1" NPT FEMALE OUTLET STAINLESS STEEL BOWL POWDER COATED CAST ALUMINUM FLOOR FLANGE SCH 80 PVC PIPE AND FITTINGS ABS PLASTIC SHOWER HEAD FREEZE-RESISTANT VALVES (2)GS-PLUS SPRAY HEADS DRAIN LINE TO FLOOR NOTE: SAFETY STATION WITH EYEWASH TO BE GUARDIAN, MODEL #GFR1092 OR EQUAL1. PS-3.3 DRAIN TO FLOOR TEPID WATER FROM MIXING VALVE 30 ' - 0 " 3" 6" 3" 3" 6" 1' - 0 " 5' - 0 " MA X 4.5" DETAIL - STILLING WELL PIPE SCALE: 1 1/2" = 1'-0" 6 PS-3.3 1" WIDE x 16 GA SST STRAPS, TYP OF 4 AT 5'-0" OC MAX, SECURE WITH 1/2"∅ SST ANCHORS (4" EMBED) 8"∅ PVC PIPE 1 1/2"∅ DRILLED HOLE, TYP PROVIDE 6 ROWS OF HOLES SPACED AT 4.5" OC TY P TY P 1' - 0 " 3' - 0 " TOP OF ACCESS HATCH / SLAB SHOCK ARRESTOR TYPE "A" 1 1/4" TEPID WATER TO EMERGENCY SHOWER 3/4" COLD WATER CHECK VALVE MIXING VALVE 3/4" HOT WATER CHECK VALVE MIXING VALVE NO SCALE 2 PS-3.3 IN-LINE EXPANSION TANK - PROVIDED WITH & SIZED FOR EACH WATER HEATER ATMOSPHERIC VACUUM BREAKER DIELECTRIC UNION (TYP.) PIPE THERMOMETER (TYP.)CHECK VALVE (TYP.) BALL VALVE (TYP.) COLD WATER SUPPLY HOT WATER SUPPLY115 DEG. PIPE UNION (TYP.) WATER HEATER T&P VALVE 3/4" DRAIN PIPE DRAIN TO FLOOR DRAIN 1.PIPING SHALL BE INSTALLED IN A ORDERLY FASHION PER THIS DETAIL, AND MANUFACTURERS RECOMMENDATIONS. 2. SEE FLOOR PLANS FOR PROPER CW & HW SUPPLY LINE SIZES. 3. WATER HEATER SIZE: 30 GALLON, 208V, 3-PH, 4.5KW. 4. CHECK VALVES INSTALLED IN VERTICAL SHALL BE SPRING LOADED STYLE. 5. APPROVED MANUFACTURERS: A.O. SMITH, BRADFORD WHITE, STATE. ELECTRICAL WATER HEATER3 NO SCALEPS-3.3 MIN. 2" HIGH PREFAB CONCRETE PAD BY PLUMBING CONTRACTOR PAINTED OSHA YELLOW.WATER HEATER NOTES: T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ P S - 2 . 0 P S T A T I O N . d w g LL O R S C H E I D E R 10 / 2 9 / 2 0 2 5 9 : 4 1 A M DE T A I L S PS-3.3 BJPO EML NTD PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 TYP. SHOCK ARRESTOR SCHEDULE SEE MANUFACTURER RECOMMENDATION FOR SIZING OF SHOCK ARRESTORS ON LENGTHS OF PIPE OVER 25 FT. SHOCK ARRESTOR TO BE BY ZURN, SMITH OR JOSAM.2. 1. NOTES: ZURN SHOCKTROL SIZE Z-1700 SERIES #100 MANUFACTURER P.D.I UNITS A FIXTURE UNITS 1-11 PIPE SIZE ARRESTOR LENGTH 3-3/4"1/2" 15" x 15" x 4" THK. CONCRETE PAD SIPHON BREAK 24 " M I N . 3' M I N . DRAIN PORT NON-FREEZE YARD HYDRANT NOT TO SCALE 1 CU. FT. OF #57 WASHED STONE HOSE BIBB SHALL ACCOMMODATE STD. ƒ" GARDEN HOSE. FREEZELESS YARD HYDRANT WOODFORD MODEL W-34 OR APPOROVED EQUAL 2" POTABLE WATER PIPE (METAL PIPE OR PROVIDE OUTER SLEEVE PROTECTION) 1 PS-3.3 2" POTABLE WATER PIPE 10/29/2025 T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ P S - 2 . 0 P S T A T I O N . d w g LL O R S C H E I D E R 10 / 2 9 / 2 0 2 5 9 : 4 1 A M DE T A I L S PS-3.4 BJPO EML NTD PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 12" 1 2" COVER LETTERING DETAIL RING AND COVER SHALL HAVE TOTAL COMBINED WEIGHT OF 300 LB MIN. AND BE SUITABLE FOR H-20 LOADING NOTE: TOP OF COVER BOLT DOWN COVER W/ 4 1/2" BOLT HOLES AT 90° AND RECESS FOR BOLT HEADS 3/8" LAG BOLTS (TYP.OF 4) BOTTOM OF COVER SA N I TA R Y S EW E R S T OR M SEW E R W A TE R POLYVINYL GASKET BETWEEN COVER AND FRAME SEAT THREADED HOLES-4 AT 90° 412" x 134" STAINLESS STEEL (TYPE 316) HEX HEAD BOLTS 3/8" LAG BOLT (TYP. OF 4) 2'-1 14" 1'-11 34" 1'-11 12"3/4"3/4" 38"3"2 18"1" 1/2" 2 3 4" 3 34" 2'-9 14" 2'-0 12" 1'-10 14" 4 38" 1 18" 4 38" 1 18" 18" CLR FULL PERIMETER 7 12" 4 34" 1 12" 1 PS-3.4 NOT TO SCALE WATERTIGHT MANHOLE RING AND COVER PIPE CONTROL ROD DIAMETER PLATES PER FLANGE SIDE PLATE THICKNESS NOMINAL PIPE SIZE 6"-8" 0.50" 2 P/SIDE 0.75" 10"-14" 0.75" 3 P/SIDE 0.75" 16"-18" 0.75" 4 P/SIDE 1" ELEVATION SECTION NOTES: 1.BOLTS: ASTM A-307 GALV. 2.RETENTION PLATE: ASTM A36 STEEL, HOT DIPPED GALV. 3.RETENTION PLATE DIAMETER SHALL BE AS REQUIRED TO PROVIDE MIN. 1/8" CLEARANCE BETWEEN PIPE FLANGE AND CONTROL ROD. 2 PS-3.4 THRUST RETENTION PLATE NOT TO SCALE CONTROL RODRUBBER WASHERSTEEL WASHER RETENTION PLATE CONTROL ROD DRESSER COUPLING STANDARD PIPE FLANGE PIPE FLANGE DIAMETER RETENTION PLATE 1/8" CLEAR RETENTION PLATE DIA. (SEE NOTE 3) 1 1/2" BOLT DIA. 3 PS-3.4 NO SCALE LAY DOWN BOLLARD 10/29/2025 FM FM FM FM S S S S S S S S S S S S X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X F M F M F M F M FM FM FM FM FM FM FM FM FM W W W W W W W W W W X X XX XX W W W W W W W W W W W W W W E E E E E E PB PB S S S S S S S S SS S S L O D / T C E L O D / T C E L O D / T C E L O D / T C E L O D / T C E L O D / T C E P U E / P A E P U E / P A E P U E / P A E P U E / P A E P U E / P A E P U E / P A E P U E / P A E P U E / P A E P U E / P A E P U E P U E P U E P U E P U E P U E P U E P U E P U E PUE PUE PUE PUE PUE PUE PUE PUE PUE PUE PUE P D E P D E P D E P D E P D E P D E P D E P D E P D E P D E P D E P D E PDE PDE PDE PDE PDE PDE PDE PDE P D E P D E 2 3 2 3 2 4 2 5 2 6 2 7 2 8 2 7 2 7 27 26 25 24 23 22 21 20 T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ P S - 1 . 0 P S T A . d w g LL O R S C H E I D E R 10 / 2 7 / 2 0 2 5 3 : 0 0 P M LA N D S C A P E P L A N 0 2.5'5'10' SCALE: 1"=5' HORZ. PS-4.0 PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K P U M P S T A T I O N RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 NTD BJPO NTD/EML 1.PLANTS SHALL BE INSTALLED ACCORDING TO PLAN. 2.PLANT MATERIAL SUBSTITUTIONS ALLOWED ONLY UPON WRITTEN PERMISSION OF ENGINEER. 3.ALL PLANT MATERIAL SHALL BE FIELD GROWN. PLANTS SHALL HAVE A HABIT OF GROWTH THAT IS NORMALFOR THE SPECIES AND SHALL BE SOUND, HEALTHY, VIGOROUS AND FREE FROM INSECTS, DISEASES AND INJURIES. ALL PLANTS SHALL EQUAL OR EXCEED THE MEASUREMENTS SPECIFIED IN THE PLANT LIST. REQUIREMENTS FORMEASUREMENTS, BRANCHING, GRADING, QUALITY, BALLING AND BURLAPPING OF PLANTS IN THE PLANT SCHEDULE SHALL GENERALLY FOLLOW THE CODE STANDARDS CURRENTLY RECOMMENDED IN THE AMERICAN STANDARDS FOR NURSERY STOCK. PRUNE TO SHAPE, PRUNING OUT BROKEN OR OVERLAPPING/RUBBING BRANCHES ONLY AS NECESSARY AT TIME OF PLANTING. 1.VERIFY LOCATION OF ALL UTILITY LINES, ABOVE AND BELOW GROUND, PRIOR TO COMMENCING INSTALLATION. THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE MADE TO UTILITIES THROUGH THE ACTIONS OF HIS OR HER EMPLOYEES. 2.ANALYZE ON-SITE SOIL TO ASCERTAIN PERCENTAGE OF NITROGEN, PHOSPHORUS, POTASH, SOLUBLE SALT AND ORGANIC MATTER, AND pH VALUE PRIOR TO INSTALLING PLANT MATERIALS. LIME APPLICATION RATE AND FERTILIZER FORMULA RATE SHALL BE BASED ON LABORATORY ANALYSIS. WRITTEN PROOF OF ANALYSIS AND APPLICATION RATES SHALL BE MAINTAINED. 3.PLANTING SOIL SHALL BE A UNIFORM MIXTURE OF 5% BY VOLUME PEAT OR OTHER APPROVED ORGANIC MATTER SUCH AS DECAYED BARK, SAWDUST OR COMPOST MATERIAL WITH ON-SITE SOIL. SATURATE SOIL WITH WARM WATER TO TEST DRAINAGE. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE DRAINAGE FROM ALL PLANT PITS AND PLANT BEDS. IF DURING THE PLANTING OPERATIONS, THE LANDSCAPE CONTRACTOR DETERMINES THAT DRAINAGE CONDITIONS ARE SUCH THAT DRAIN LINES OR OTHER DRAINAGE IMPROVEMENT MEASURES ARE NECESSARY, HE OR SHE SHALL INSTALL THE NECESSARY MEASURES. 4.DELIVER FRESHLY DUG PLANT MATERIALS AFTER PREPARATIONS FOR PLANTING HAVE BEEN COMPLETED. INSTALL PLANT MATERIALS IMMEDIATELY. PROTECT BARK, BRANCHES AND ROOT SYSTEMS DURING HANDLING. IF PLANTING IS DELAYED, PROTECT PLANT MATERIALS FROM DAMAGE AND WATER THOROUGHLY AS NEEDED. HEEL-IN BALLED AND BURLAPPED PLANT MATERIALS AND KEEP CONTAINER GROWN STOCK IN CONTAINER UNTIL TIME OF PLANTING. 5.DO NOT INSTALL PLANT MATERIAL WHEN AMBIENT TEMPERATURES MAY DROP BELOW 35° F (2° C) OR RISE ABOVE 90° F (32° C).DO NOT INSTALL PLANT MATERIAL WHEN WIND VELOCITY EXCEEDS 30 mph (48k/hr). 6.PLACE PLANT VERTICAL AND ORIENT FOR BEST APPEARANCE. REMOVE SYNTHETIC CONTAINERS, BURLAP, ROPES AND WIRES FROM ROOT BALLS. CUT AND FOLD DOWN NATURAL BURLAP MATERIAL FROM THE TOP OF THE ROOT BALL. SATURATE SOIL WITH WATER WHEN THE PIT OF BED IS HALF FULL OF PLANTING SOIL AND AGAIN WHEN FULL. 7.AFTER PLANTING AND BEFORE APPLICATION OF MULCH, TREAT GROUND WITH RONSTAR-G OR APPROVED EQUAL. 8.ALL TREES AND SHRUBS SHALL RECEIVE SAUCERS AND MULCH. MULCH BED SHALL BE A MINIMUM OF 3' FROM THE ROOT BALL OF SHRUBS AND 5' FROM THE ROOT BALL OF TREES.PLANT BEDS SHALL BE MULCHED AS A CONTINUOUS MASS AND BED LINES SHALL HAVE CLEAN, SHARP EDGES CUT WITH SPADE. 9.SHREDDED PINE BARK MULCH SHALL BE APPLIED TO ALL PLANTING BEDS TO A MINIMUM DEPTH OF FOUR (4) INCHES. KEEP MULCH AWAY FROM TREE TRUNKS AND SHRUBS. SOIL SHALL NOT BE LEFT EXPOSED WITHIN ANY PLANTING PITS OR BEDS. MULCH BED SHALL BE WEED FREE AND CONFORM TO THE SPECIFIED DEPTH AT THE TIME OF FINAL INSPECTION. 1.AFTER ACCEPTANCE AT THE TIME OF FINAL INSTALLATION INSPECTION, ALL PLANTS SHALL BE WARRANTED FOR ONE YEAR. PLANT MATERIALS SHALL BE ALIVE AND IN SATISFACTORY GROWTH AT THE END OF THE WARRANTY PERIOD. ONE THOROUGH WEEDING AND REPLENISHING OF MULCH (MINIMUM 2") SHALL BE REQUIRED IMMEDIATELY PRIOR TO THE INSPECTION AT THE END OF THE WARRANTY PERIOD. 2.AT THE END OF THE WARRANTY PERIOD, NEW HANOVER COUNTY STAFF WILL INSPECT THE PROJECT SITE. ANY PLANT THAT IS DEAD, MISSING OR NOT IN SATISFACTORY GROWTH SHALL BE REMOVED FROM THE SITE AND REPLACED. REPLACEMENT PLANTS SHALL BE OF THE SAME SIZE AND SPECIES AS ORIGINALLY SPECIFIED. PLANTING MATERIALS INSTALLATION OF PLANT MATERIALS WARRANTY OF PLANT MATERIALS 47 IN @ 6' SPACING & 4' OFF FENCE U.O.N. SPREAD 4" SHREDDED PINEBARK MULCH. KEEP AWAY FROM SHRUB BASE 3" EARTHEN SAUCER PLACE TOP OF ROOT BALL LEVEL W/ SURROUNDING SOIL PREPARED PLANTING SOIL TO DEPTH OF 4" TO 6" BELOW ROOTBALL UNDISTURBED SUBGRADE TO HOLD ROOTBALL REMOVE CONTAINER AND/OR BURLAP FROM ROOTBALL PLANT PIT 2 TIMES DIAMETER OF ROOTBALL 1 PS-4.0 SHRUB PLANTING DETAIL NOT TO SCALE IN LANDSCAPE MATERIAL LIST REF KEY NELLIE STEVENS HOLLY COMMON NAME ILEX 'NELLIE R STEVENS' BOTANICAL NAME 47 NUMBER 5.5 GAL SIZE 7 ' - 6 " N A D 8 3 ( 2 0 1 1 ) 10/29/2025 E-0.1 AB B R E V I A T I O N S , L E G E N D S , A N D N O T E S T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ E - 0 . 1 E - S H T S . d w g HB O U R N E 10 / 3 0 / 2 0 2 5 3 : 2 7 P M ABBREVIATIONS: AE ANALYSIS ELEMENT AF AMPERE FRAME AFE ACTIVE FRONT END AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHU AIR HANDLING UNIT AIC AMPERE INTERRUPTING CAPACITY AIT ANALYSIS INDICATING TRANSMITTER ANSI AMERICAN NATIONAL STANDARDS INSTITUTE ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS AT AMPERE TRIP ATS AUTOMATIC TRANSFER SWITCH BC BYPASS CONTACTOR BCC BARE COPPER CONDUCTOR BKR BREAKER CJB CONTROL JUNCTION BOX CKT CIRCUIT CPT CONTROL POWER TRANSFORMER CT CURRENT TRANSFORMER DB DUCTBANK DSW DISCONNECT SWITCH EHH ELECTRIC HAND HOLE EMH ELECTRIC MAN HOLE EO ELECTRICALLY OPERATED EPO EMERGENCY POWER OFF ETM ELAPSED TIME METER ETU ELECTRONIC TRIP UNIT FAAP FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FE FLOW ELEMENT FIT FLOW INSTRUMENT TRANSMITTER FS FLOW SWITCH FSL FLOW SWITCH LOW FVNR FULL VOLTAGE NON-REVERSING FVR FULL VOLTAGE REVERSING GFCI GROUND FAULT CIRCUIT INTERRUPTER GFCT GROUND FAULT CURRENT TRANSFORMER GND GROUND HOA HAND-OFF-AUTO HPU HYDRAULIC POWER UNIT IC INPUT CONTACTOR IEEE INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS ISO INTERNATIONAL ORGANIZATION FOR STANDARDIZATION JBX JUNCTION BOX LCS LOCAL CONTROL STATION LP LIGHTING PANEL LS LEVEL SWITCH LSL LEVEL SWITCH LOW LSH LEVEL SWITCH HIGH LSHH LEVEL SWITCH HIGH-HIGH LT LEVEL TRANSMITTER MCC MOTOR CONTROL CENTER MFR MULTI-FUNCTION RELAY MH MAN HOLE MOD MOTOR OPERATED DAMPER MOG MOTOR OPERATED GATE MOL MOTOR OPERATED LOUVER MOV MOTOR OPERATED VALVE MPR MOTOR PROTECTION RELAY MTD MOUNTED MTS MANUAL TRANSFER SWITCH MWTS MOTOR WINDING TEMPERATURE SWITCH NC NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFPA NATIONAL FIRE PROTECTION ASSOCIATION NL NIGHT LIGHT NO NORMALLY OPEN NTS NOT TO SCALE OC OUTPUT CONTACTOR OL OVERLOAD PC PHOTOCELL PCC POINT OF COMMON COUPLING PE PRESSURE ELEMENT PIT PRESSURE INDICATING TRANSMITTER PJB POWER JUNCTION BOX PLC PROGRAMMABLE LOGIC CONTROLLER PNL PANEL PP POWER PANEL PST PHASE SHIFTING TRANSFORMER PT POTENTIAL TRANSFORMER PTT PUSH TO TEST RCS REMOTE CONTROL STATION RECP RECEPTACLE RIO REMOTE I/O RM ROOM RTD RESISTANCE THERMAL DEVICE RTU REMOTE TELEMETRY UNIT RVAT REDUCED VOLTAGE AUTO TRANSFORMER RVSS REDUCED VOLTAGE SOLID STATE SA SUPPLY AIR SE SERVICE ENTRANCE SPD SURGE PROTECTIVE DEVICE SST STAINLESS STEEL TB TEST BLOCK TC TIMED CLOSE TO TIMED OPEN TSP TWISTED SHIELDED PAIR TST TWISTED SHIELDED TRIAD TX TRANSFORMER TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY VFD VARIABLE FREQUENCY DRIVE WPCR WEATHER PROOF CORROSION RESISTANT WT WALK THROUGH XFMR TRANSFORMER WIRING: CONDUIT HOME RUN CONDUIT EXPOSED CONDUIT ENCASED CONDUIT CONDUIT CONCEALED FLEXIBLE CONDUIT CONCRETE ENCASED DUCTBANK LEFT: CONDUIT RISE (TURN UP) RIGHT: CONDUIT DROP (TURN DOWN) LIGHTING: X DENOTES FIXTURE TYPE (TYP.): REFER TO FIXTURE SCHEDULE # DENOTES CIRCUIT NUMBER (TYP.) RECTANGULAR FIXTURE XXX # XXX # LEFT:CEILING-MOUNTED FIXTURE RIGHT:WALL-MOUNTED FIXTURE # XXX # XXX EMERGENCY WALL-MOUNTED FIXTURE: LEFT:STANDARD RIGHT:REMOTE-HEAD XXX # XXX # LEFT:CEILING-MOUNTED EXIT SIGN RIGHT:WALL-MOUNTED EXIT SIGN SHADED PORTION DENOTES SIGN FACE XXX #POLE-MOUNTED FIXTURE PC PHOTOCELL OS X LEFT:CEILING-MOUNTED OCCUPANCY SENSOR RIGHT: WALL-MOUNTED OCCUPANCY SENSOR X DENOTES TYPE SWITCHES: COMMUNICATIONS: TELEPHONE OR NETWORK DROP PAGER RECEPTACLE HORN/LIGHT DEVICE PA UNIT HVAC AND FIRE ALARM: FIRE ALARM CONTROL PANEL FIRE ALARM ANNUNCIATOR PANEL F FIRE ALARM PULL STATION X #FIRE ALARM INDICATOR: X DENOTES ALARM TYPE: (TYP.): A DENOTES AUDIBLE V DENOTES VISIBLE (# DENOTES STROBE INTENSITY) F X # FIRE ALARM INDICATOR MOUNTED ABOVE A FIRE ALARM PULL STATION DD DUCT DETECTOR SMOKE DETECTOR: X DENOTES TYPE: (TYP.): Z DENOTES IONIZATION P DENOTES PHOTOELECTRIC T DENOTES THERMAL H HEAT DETECTOR T THERMOSTAT R AMBIENT TEMPERATURE TRANSMITTER MISCELLANEOUS PLAN VIEW SYMBOLS: EQUIPMENT CONNECTIONE GROUND RODS: LEFT: BURIED RIGHT: IN TESTWELL EXX DBXX DUCTBANK SECTION CUT IDENTIFIER: DBXX DENOTES DUCTBANK ID EXX DENOTES DRAWING NUMBER WHERE SECTION CUT IS LOCATED DB X #DUCTBANK TAG: X DENOTES DUCTBANK ID TRAY X Y X Y CABLE TRAY TAG: X DENOTES CABLE TRAY ID Y DENOTES SCHEDULE REFERENCE INSTRUMENT TAG: X DENOTES INSTRUMENT TYPE # DENOTES INSTRUMENT NUMBER P-XXXX P-XXX-XXX CONDUIT TAGS: P DENOTES POWER C DENOTES CONTROL I DENOTES INSTRUMENTATION XXXX DENOTES CONDUIT ID XXX-XXX DENOTES CONDUIT ID ELEMENTARY CONTROL SCHEMATICS: XOO OOX AOH 3-POSITION SELECTOR SWITCH: HOA DENOTES HAND/OFF/AUTO LOR DENOTES LOCAL/OFF/REMOTE FOR DENOTES FORWARD/OFF/REVERSE START STOP PUSHBUTTON SWITCHES: LEFT: N.O./RIGHT: N.C. TEXT DENOTES LEGEND PLATE E-STOP MUSHROOM HEAD EMERGENCY STOP PUSHBUTTON SWITCH N.C. MAINTAINED: TEXT DENOTES LEGEND PLATE STOP L.O. PUSHBUTTON SWITCH N.C. WITH LOCK-OUT: TEXT DENOTES LEGEND PLATE STOPSTART SELECTOR SWITCH: TEXT DENOTES LEGEND PLATE OL THERMAL OVERLOAD RELAY NORC NOFC NCRO NCFO TEMPERATURE SWITCHES/ THERMOSTATS PRESSURE SWITCHES LEVEL SWITCHES FLOW SWITCHES NOTC NOTO NCTO NCTC TIME DELAY SWITCHES NO NC DISCONNECT SWITCHES NOTATION LEGEND: NO/NC: NORMALLY OPEN/CLOSED RO/RC: RISE-TO-OPEN/CLOSE FO/FC: FALL-TO-OPEN/CLOSE TO/TC: TIME-OPEN/CLOSE CONTACTS: TEXT DENOTES COIL ID SWITCHES: TEXT DENOTES TAG NUMBER LIMIT SWITCHES TORQUE SWITCH CONTACTS X X -TS LSLS TS TS PSPS PSPS LSLS LSLS FSFS FSFS -- TDTD TDTD COIL: X DENOTES TYPE: M DENOTES MOTOR STARTER CR DENOTES CONTROL RELAY TD DENOTES TIME DELAY RELAY PR DENOTES INTERPOSING PILOT RELAY LC DENOTES LIGHTING CONTACTOR Y DENOTES REFERENCE LINE NUMBER X PTT X INDICATOR LIGHT: LEFT: STANDARD/RIGHT: PUSH-TO-TEST X DENOTES COLOR RUN TIME METER SV SOLENOID VALVE MPR MOTOR PROTECTION RELAY VA V 100 480/120 CONTROL POWER TRANSFORMER MECHANICAL INTERLOCK CONNECTION MSH MOTOR SPACE HEATER XX YYY EQUIPMENT/DEVICE LOCATION SYMBOLS: LOCATED AT PANEL: X DENOTES PANEL ID: L DENOTES LOCAL CONTROL STATION LOCATED IN FIELD LOCATED IN STAND-ALONE MOTOR STARTER/CONTROLLER LOCATED IN MCC X SINGLE-LINE DIAGRAMS: TRANSFORMER PROTECTIVE RELAY: NUMBER DENOTES IEEE DEVICE FUNCTION MOTOR AND TYPICAL ADDITIONAL DEVICES: MWTS: MOTOR-WINDING TEMPERATURE SWITCH MSH: MOTOR SPACE HEATER CF: COOLING FAN TE: TEMPERATURE ELEMENT ME: MOISTURE DETECTOR FUSE: NUMBER DENOTES RATING LOW-VOLTAGE POWER CIRCUIT BREAKER: LEFT: FIXED-MOUNT RIGHT: DRAWOUT E.O. DENOTES ELECTRICALLY OPERATED LSIG DENOTES INSTALLED TRIP FUNCTIONS: L DENOTES LONG-TIME S DENOTES SHORT-TIME I DENOTES INSTANTANEOUS G DENOTES GROUND FAULT CTR DENOTES BREAKER-SPECIFIC CT AND RATIOS MEDIUM-VOLTAGE DRAWOUT POWER CIRCUIT BREAKER: NUMBER DENOTES AMP SIZE E.O. DENOTES ELECTRICALLY OPERATED BATT. DENOTES BATTERY BACKUP POWER GROUND CT: NUMBERS DENOTE CT WINDING RATIO AND CT QUANTITY DRAW-OUT ELEMENT LIGHTNING ARRESTOR PT: NUMBERS DENOTE PT WINDING VOLTAGES AND PT QUANTITY GFCT: NUMBERS DENOTE GFCT WINDING RATIO AND GFCT QUANTITY MOTOR CIRCUIT PROTECTOR NUMBER DENOTES RATING LEFT: PANELBOARD RIGHT: MINI POWER CENTER X DENOTES PANEL ID INSTRUMENT TAG: X DENOTES INSTRUMENT TYPE Y DENOTES INSTRUMENT NUMBER LOW-VOLTAGE MOLDED CASE CIRCUIT BREAKER LEFT: THERMAL-MAGNETIC TRIP UNIT RIGHT: ELECTRONIC TRIP UNIT TRANSFORMER ID _KVA 480-120/208V 3P/4W DRY TRANS # HP RPM MWTS MSH CF TE ME XX X - Y Y Y Y Y #A #A 3P #A FUSED DISCONNECT SWITCH: NUMBER DENOTES RATING #A 3P #A 3P DISCONNECT SWITCH: NUMBER DENOTES RATING #A 3P #A 3P FUSED DISCONNECT SWITCH: NUMBER DENOTES RATING 800AF 800AP 800AT LSIG N.C. 800AF 800AP 800AT LSIG N.C. 52 #A N.C. E.O. BATT. ETU 800AF 800AP 800AT LSIG MCP #A 600:5 (3) 50:5 (1) (2) 480:120 X X LEFT: FVNR STARTER: X DENOTES NEMA SIZE DP DENOTES DEFINITE PURPOSE CONTACTOR NUMBER DENOTES RATING RIGHT: FVR STARTER X DENOTES NEMA SIZE DP DENOTES DEFINITE PURPOSE CONTACTOR NUMBER DENOTES RATING LEFT: RESISTOR RIGHT: LINE REACTOR: #% DENOTES IMPEDANCE CAPACITOR LEFT: VFD WITH LINE REACTOR NUMBER DENOTES RATING MIDDLE: VFD WITH HARMONIC FILTER NUMBER DENOTES RATING RIGHT: VFD WITH LINE REACTOR AND FVNR BYPASS NUMBER DENOTES RATING X DENOTES NEMA SIZE #% V VS VOLTMETER AND SWITCH A AS AMMETER AND SWITCH SHUNT TRIP SPD XXXkA SURGE PROTECTIVE DEVICE K KIRK-KEY INTERLOCK A MCP # X M F R A MCP # X 6 PULSE VFD MCP A# 5% SINGLE-LINE DIAGRAMS CONTINUED: 6 PULSE VFD MCP IC A OC # 5% X6 PULSE VFD MCP A ACTIVE FILTER # VFD WITH ACTIVE FRONT END NUMBER DENOTES RATING LEFT: RVSS STARTER NUMBER DENOTES RATING RIGHT: RVSS STARTER WITH FVNR BYPASS NUMBER DENOTES RATING X DENOTES NEMA SIZE RVAT STARTER: NUMBER DENOTES RATING X DENOTES NEMA SIZE #% DENOTES TAP SETTING RVSS OC MCP A# RVSS IC OC MCP A# X MCP A# X X X #% GENERATOR NUMBER DENOTES SIZE CONTACTOR-STYLE ATS OR MTS: NUMBER DENOTES VOLTAGE X DENOTES AMPS/FRAME/TRIP Y DENOTES kA RATING CONTACTOR-STYLE ATS OR MTS, SERVICE-ENTRANCE RATED: NUMBER DENOTES VOLTAGE X DENOTES AMPS/FRAME/TRIP Y DENOTES kA RATING #kW480V,3Ø,4W L S1 S2 ATS #V, XA 3Ø 4W 4P YkA OPEN TRANSITION (S.E. RATED) L S1 S2 ATS #V, XA 3Ø 4W 4P YkA OPEN TRANSITION (S.E. RATED) CONTACTOR-STYLE ATS OR MTS WITH OFF POSITION: NUMBER DENOTES VOLTAGE X DENOTES AMPS/FRAME/TRIP Y DENOTES kA RATING L S1 S2 ATS #V, XA 3Ø 4W 4P YkA OPEN TRANSITION (S.E. RATED) S1 S2 L ATS #V, XAF/XAT 3Ø 4W 4P YkA OPEN TRANSITION MCCB-STYLE ATS OR MTS: NUMBER DENOTES VOLTAGE X DENOTES AMPS/FRAME/TRIP Y DENOTES kA RATING S1 S2 L ATS #V, XAF/XAT 3Ø 4W 4P YkA OPEN TRANSITION DRAWOUT CB-STYLE ATS OR MTS: NUMBER DENOTES VOLTAGE X DENOTES AMPS/FRAME/TRIP Y DENOTES kA RATING INSTRUMENT TRANSMITTER PS TS PRESSURE SWITCH TEMPERATURE SWITCH OL THERMAL OVERLOAD RELAY NOTES: 1.UNLESS SPECIFICALLY NOTED OTHERWISE, ALL UNDERGROUND ELECTRICAL CONDUITS SHALL BE DIRECT BURIED WITH 30" MINIMUM COVER. 2.THE INSTALLATION OF ALL CONCRETE ENCASED ELECTRICAL CONDUITS SHALL COMPLY WITH ACI 318, SECTION 6.3. CONTRACTOR SHALL SUPPLY EXPANSION JOINT FITTINGS AS REQUIRED FOR THERMAL EXPANSION AND DEFLECTION. 3.BOND ALL NEW CONCRETE ENCASED GROUND CONDUCTORS TO EXISTING GROUND CONDUCTORS IN ALL MANHOLES, PULL BOXES, CABLE TRAYS, AND SIMILAR LOCATIONS WHERE APPLICABLE. 4.UNLESS OTHERWISE SPECIFIED OR NOTED, ALL WALL MOUNTED ELECTRICAL PANELS, ENCLOSURES, AND SIMILAR EQUIPMENT SHALL BE MOUNTED 6'-6" (MAX) FROM THE TOP OF THE PANEL TO FINISHED FLOOR OR GRADE. 5.UNLESS OTHERWISE NOTED, ALL LIGHTING SWITCHES, CONTROL SWITCHES, AND SIMILAR EQUIPMENT SHALL BE MOUNTED WITH THEIR CENTERLINE APPROXIMATELY 4'-0" ABOVE FINISHED FLOOR, SLAB, OR GRADE. THERMOSTATS SHALL BE MOUNTED 4'-4" ABOVE FINISHED FLOOR. 6.A SEPARATE EQUIPMENT GROUNDING CONDUCTOR SHALL BE PROVIDED FOR EACH CIRCUIT (SEPARATE CONDUCTOR IN THE CONDUIT). THE CONDUCTOR SHALL BE TERMINATED AT THE PROPER DEVICE, TERMINAL, OR LUG AT THE POWER SOURCE (MCC GROUND BUS, PANELBOARD GROUND BUS, ETC.). GROUND CONDUCTOR SIZE SHALL BE PER THE LATEST EDITION OF THE NEC. 7.ELECTRICAL SYSTEMS INSTALLED IN HAZARDOUS LOCATIONS SHALL BE CONSTRUCTED IN ACCORDANCE WITH CHAPTER 5, ART. 500 OF THE LATEST EDITION OF THE NEC. CONTRACTOR SHALL SEAL ALL CONDUITS LEAVING HAZARDOUS AREAS. WALL AND FLOOR OPENINGS SHALL BE SEALED WITH FIREPROOF COMPOUND. 8.ALL EQUIPMENT LOCATED IN HAZARDOUS AREAS SHALL BE SUITABLE FOR THE CLASS, DIVISION, AND GROUP RATING OF THE LOCATION. 9.CONDUIT HOMERUNS ARE NOT SHOWN ON DRAWINGS. CONTRACTOR SHALL REFER TO CONDUIT AND WIRE SCHEDULE, RISER DIAGRAMS, SINGLE LINE DIAGRAMS, AND OTHER DRAWINGS FOR CONDUIT AND WIRE REQUIREMENTS. ST S X PA ETM AF AT 100A 100A X # OS X MCP AFE VFD A# PLAN SYMBOLS: PANELS AND BOXES: JUNCTION BOXJB PULL BOXPB CONTROL PANEL RECEPTACLES: X # X DENOTES RECEPTACLE TYPE (TYP.): GFCI DENOTES GROUND FAULT CIRCUIT INTERRUPT UPS DENOTES UNINTERRUPTIBLE POWER SUPPLY WPCR DENOTES WEATHERPROOF CORROSION RESISTANT # DENOTES CIRCUIT NUMBER (TYP.) DUPLEX RECEPTACLE X #SIMPLEX RECEPTACLE X #QUADRUPLEX RECEPTACLE # X MULTI-OUTLET RECEPTACLE SIMPLEX # X MULTI-OUTLET RECEPTACLE DUPLEX # X 240 VOLT RECEPTACLE SPECIAL PURPOSE OUTLET# X CP 208/120V PANEL BOARD 480/277V PANEL BOARD X #WALL SWITCH: X DENOTES TYPE: NO SUBSCRIPT DENOTES SINGLE-POLE SWITCH 3 DENOTES 3-WAY SWITCH 4 DENOTES 4-WAY SWITCH M DENOTES MANUAL MOTOR STARTER #DENOTES CIRCUIT NUMBER WPCR DENOTES WEATHERPROOF CORROSION RESISTANT COMBINATION MOTOR STARTER DISCONNECT SWITCH LOCAL CONTROL STATION MOTOR STARTER T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ E - 0 . 1 E - S H T S . d w g HB O U R N E 10 / 3 0 / 2 0 2 5 3 : 2 7 P M PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 HMB HMB HMB 10/30/2025 FM S S S S S S X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X F M F M FM FM FM FM X X R / W R / W R / W R/ W R / W R / W R / W R / W R / W R / W R / W R/ W R / W R / W PB PB W W W SS SS SS SS SS SS SS S S S S S S S S S S S S S S S S W W 1 1 + 0 0 W W W W W W W W W W W FM FM FM W W W FM S S S S S S X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X F M F M FM FM FM FM X X R / W R / W R / W R/ W R / W R / W R / W R / W R / W R / W R / W R/ W R / W R / W PB PB PU M P S T A T I O N EL E C T R I C A L S I T E P L A N 0 5'10'20' SCALE: 1"=10' HORZ.E-1.0 N A D 8 3 ( 2 0 1 1 ) PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K P U M P S T A T I O N RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 NTD BJPO NTD/EML HMB HMB HMB #1/0 BCC GROUND RING NEW GROUND ROD WITH TEST WELL, SEE DETAIL 2/E-3.4 T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ E - 1 . 0 P S T A . d w g HB O U R N E 10 / 3 0 / 2 0 2 5 3 : 2 9 P M T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ E - 1 . 0 P S T A . d w g HB O U R N E 10 / 3 0 / 2 0 2 5 3 : 2 9 P M NOTES: 1.SEE THE CIVIL SITE PLAN FOR ALL EQUIPMENT DETAILS. WETWELL VALVE VAULT MAG METER RPZ BACKFLOW PREVENTER PUMP STATION CONTROLS BUILDING GRINDER CONTROL PANEL GRINDER GENERATOR ON CONCRETE PAD, SEE DETAIL 1/E-3.3 DECORATIVE FENCE CRANE UTILITY TRANSFORMER, SEE DETAIL 3/E-3.3 METER BASE ON EQUIPMENT RACK, SEE DETAIL PS-E6/E-3.1 FUTURE ODOR CONTROL DUPLEX SUBMERSIBLE PUMPS TERMINAL CABINET, TC-1 ON EQUIPMENT RACK, SEE DETAIL PS-E14/ POWER HANDHOLE EHH-1 CONTROL HANDHOLE EHH-2 11"×18"×12" MINIMUM GFCI/WPCR MPC-1:4 SITE LIGHT FIXTURE LL1MPC-1:3 VIA TS 10/30/2025 2' - 0 " 3'-0" 6'-0" 11 ' - 6 " ' 12 ' - 0 " 19'-6"' 20'-0" 4' - 0 " 2'-0" 1' - 1 " ' EQUIPMENT BUILDING PLAN SCALE: 1" = 20' 1 E-1.1 T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ E - 1 . 1 E - S H T S . d w g HB O U R N E 10 / 3 0 / 2 0 2 5 3 : 3 3 P M NOTE: EQUIPMENT SIZES SHOWN ARE BASED UPON EQUIPMENT USED AS BASIS OF DESIGN. IF EQUIPMENT ACTUALLY USED DIFFERS IN SIZE FROM THAT SHOWN, ADJUST MOUNTING PLACEMENTS AS REQUIRED. ECB-1 ATS-1 MDP-1 SPD EXTERIOR LIGHT GRAB HANDLE HVAC THERMOSTAT (MOUNT 5' A.F.F.) INTERIOR LIGHT MINI-SPLIT SYSTEM HVAC (INDOOR UNIT/WALL MOUNTED) ALARM LIGHT AND HORN MPC-1 PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 DTSS SCADA RTU-1 PUMP CONTROL PANEL PCP-1 FUTURE WATER HEATER AND MIXING VALVE NIC SUBMERSIBLEPUMP SP-1RVSS SUBMERSIBLEPUMP SP-2RVSS FLOW METER DISPLAY GFCI/WPCR MPC-1:18 E-1.1 PU M P S T A T I O N EL E C T R I C A L R O O M P L A N A N D LI G H T F I X T U R E S C H E D U L E FUTURE SUBMERSIBLE PUMP SP-2 VFD NIC FUTURE SUBMERSIBLE PUMP SP-1 VFD NIC HMB NTD/HMB HMB MINI-SPLIT SYSTEM HVAC (OUTDOOR UNIT) MINI-SPLIT SYSTEM HVAC LOCAL DISCONNECT GFCIMPC-1:2 GFCI MPC-1:2 SPD LC1MPC-1:1 LC1MPC-1:1 LC1MPC-1:1 LC1MPC-1:1 LW1 MPC-1:3 VIA TS T GENERATORDOCKINGSTATION 1 OS MPC-1:1 EM1 TS 10/30/2025 T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ E - 2 . 0 E _ S H T S . d w g HB O U R N E 10 / 3 0 / 2 0 2 5 3 : 3 0 P M L N E AF AT 25 0 25 0 150kW 480V,3ɸ,4W P-1007 P-1037 P-1010 C-1002 P-1003 P-1005 NOTES: 1.CONTRACTOR SHALL COORDINATE ALL ELECTRICAL UTILITY METERINGEQUIPMENT WITH THE LOCAL ELECTRICAL UTILITY. COORDINATION SHALLINCLUDE, BUT NOT BE LIMITED TO, PRIMARY CONDUIT, SECONDARYCONDUIT AND WIRE, METERING CABINET AND EQUIPMENT, AND SECONDARYDISCONNECTING MEANS. ALL COSTS RELATED TO UTILITY REQUIREMENTSSHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 2.PROVIDE DOUBLE LUGS ON LOAD SIDE OF ECB-1 FOR CONNECTION OF SPD. 3.PROVIDE THE MANUAL TRANSFER SWITCH, MTS-1, WITH A PLUG SUITABLEFOR A CONNECTION TO A TEMPORARY PORTABLE GENERATOR. COORDINATEWITH THE OWNER FOR CONNECTION TYPE. 400:5 (3) ECB-1,SEE NOTE 2 GEN-1SE RATED SEE NOTE 1 FROM ELECTRICAL UTILITY UTILITY METERING P-1000 P-1008 ATS-1480V,400A3ɸ,4W,3P42kAOPEN TRANSITION P-1038 P-1039 AF AT 225 175 AF AT 225 175 "MDP-1" 400A, 3ɸ, 4W, 480/277Vac, 35kAIC, TIN-PLATED COPPER BUS P-1001 P-1002 P-1006 P-1009 E-2.0 HMB HMB HMB PUM P S T A T I O N S I N G L E L I N E D I A G R A M , PA N E L A N D C O N D U I T A N D W I R E S C H E D U L E S PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 L S1 S2 DTSS 480V, 400A 3ɸ, 4W, 3P 100kA OPEN TRANSITION (S.E. RATED) P-1014P-1013 PUMP STATION - SINGLE LINE DIAGRAM SCALE: NTS 1 E-2.0 P-1015 P-1016 SUBMERSIBLE PUMP SP-1 MWTS 30 ME P-1017 SP-1 RVSS TO PCP-1 C-1023 200A 3P C-1024 DSW-1 NEMA 4X SST P-1012P-1011 240kA P-1004 MPC-1 GENERATORDOCKINGSTATION480V, 400A3ɸ, 4W, 4P RVSS IC OC MCP A100 3 300 KVA XX kV-480/277V 3P/4W PAD MOUNTED P-1018 P-1019 SUBMERSIBLE PUMP SP-2 MWTS 30 ME P-1020 SP-2 RVSS 200A 3P DSW-2 NEMA 4X SST RVSS IC OC MCP A100 3 AF AT 100 70 MPC-1 P-1026 A MCP 15 1 5 GRINDER AF AT 100 20 P-1024 P-1025 ETU 400AF 400AT LSI TC-1 TC-1 GRINDER CONTROL PANEL TO PCP-1 C-1023 C-1024 10/30/2025