HomeMy WebLinkAboutPlan Set 91-98E-2.1
HMB
HMB
HMB
PUM
P
S
T
A
T
I
O
N
C
O
N
T
R
O
L
R
I
S
E
R
D
I
A
G
R
A
M
,
CO
N
D
U
I
T
A
N
D
W
I
R
E
S
C
H
E
D
U
L
E
S
PERMITTING
ISSUED FOR:
DATE: 11/2025
DRAWN BY:
CHECKED BY:
PROJECT NO.:
DESIGNED BY:
3514-A
FINAL
DRAWING
FOR REVIEW
PURPOSES ONLY
NOT RELEASED FOR
CONSTRUCTION
NO
R
T
H
C
A
R
O
L
I
N
A
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
HO
L
L
Y
S
H
E
L
T
E
R
B
U
S
I
N
E
S
S
P
A
R
K
RE
V
I
S
I
O
N
S
12
0
N
o
r
t
h
B
o
y
l
a
n
A
v
e
n
u
e
· R
a
l
e
i
g
h
,
N
C
2
7
6
0
3
-
1
4
2
3
(9
1
9
)
8
2
8
-
0
5
3
1
· t
h
e
w
o
o
t
e
n
c
o
m
p
a
n
y
.
c
o
m
Li
c
e
n
s
e
N
u
m
b
e
r
:
F
-
0
1
1
5
T:
\
P
r
o
j
e
c
t
s
\
N
e
w
_
H
a
n
o
v
e
r
_
C
o
u
n
t
y
-
3
5
1
4
\
A
-
H
o
l
l
y
S
h
e
l
t
e
r
B
u
s
i
n
e
s
s
\
_
C
A
D
D
\
S
h
e
e
t
S
e
t
s
\
H
o
l
l
y
S
h
e
l
t
e
r
P
u
m
p
S
t
a
t
i
o
n
\
3
5
1
4
-
A
_
E
-
2
.
0
E
_
S
H
T
S
.
d
w
g
HB
O
U
R
N
E
10
/
3
0
/
2
0
2
5
3
:
3
1
P
M
RTU PANEL - CONTROL RISER DIAGRAM
SCALE: NTS
2
E-2.1
LE
1
LIT
1
C-1000
FE
1
FIT
1
EFFLUENT
FLOW
SP-1 RVSS SP-2 RVSS
LSHH
1
TO ANTENNA
WET WELL
LEVEL
RTU-1
GEN-1 ATS-1
C-1002
C-1008
C-1009
C-1017
C-1021SUBMERSIBLE
PUMP NO.1
RVSS
SUBMERSIBLE
PUMP NO.2
RVSS
GENERATOR
CONTROL
PANEL
AUTOMATIC
TRANSFER
SWITCH
PUMP CONTROL PANEL
PCP-1
C-1012
LS-1
VALVE VAULT
CHECK VALVE
LIMIT SWITCH
C-1006
C-1007
C-1004
C-1005
LSH
3
LSH
2
LSH
1
LSL
1
WET WELL
FLOAT SWITCHES
C-1020
C-1003C-1001
TERMINAL CABINET
TC-1
C-1013
C-1018
P-1031
120V FROM
MPC-1
P-1036
120V FROM MPC-1
C-1022
ODOR CONTROL
(FUTURE)
C-1019
ALARM LIGHT
AND HORN
C-1015
C-1014
10/30/2025
T:
\
P
r
o
j
e
c
t
s
\
N
e
w
_
H
a
n
o
v
e
r
_
C
o
u
n
t
y
-
3
5
1
4
\
A
-
H
o
l
l
y
S
h
e
l
t
e
r
B
u
s
i
n
e
s
s
\
_
C
A
D
D
\
S
h
e
e
t
S
e
t
s
\
H
o
l
l
y
S
h
e
l
t
e
r
P
u
m
p
S
t
a
t
i
o
n
\
3
5
1
4
-
A
_
E
-
3
.
0
E
_
S
H
T
S
.
d
w
g
HB
O
U
R
N
E
10
/
3
0
/
2
0
2
5
4
:
0
6
P
M
EL
E
C
T
R
I
C
A
L
D
E
T
A
I
L
S
E-3.0
HMB
HMB
HMB
NOTE:
1.CFPUA STANDARD DETAILS SHALL BE
MODIFIED SO THAT 480V, 3 PHASE
COMPONENTS WILL BE PROVIDED BY
SEPARATE EXTERNAL ELECTRICAL
EQUIPMENT AND ONLY BE SUPPLIED
WITH 120VAC.
2.PCP SHALL BE MODIFIED TO PROVIDE
CONTROL SIGNALS TO 3 EXTERNAL
PUMP MOTOR CONTROLLERS.
PERMITTING
ISSUED FOR:
DATE: 11/2025
DRAWN BY:
CHECKED BY:
PROJECT NO.:
DESIGNED BY:
3514-A
FINAL
DRAWING
FOR REVIEW
PURPOSES ONLY
NOT RELEASED FOR
CONSTRUCTION
NO
R
T
H
C
A
R
O
L
I
N
A
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
HO
L
L
Y
S
H
E
L
T
E
R
B
U
S
I
N
E
S
S
P
A
R
K
RE
V
I
S
I
O
N
S
12
0
N
o
r
t
h
B
o
y
l
a
n
A
v
e
n
u
e
· R
a
l
e
i
g
h
,
N
C
2
7
6
0
3
-
1
4
2
3
(9
1
9
)
8
2
8
-
0
5
3
1
· t
h
e
w
o
o
t
e
n
c
o
m
p
a
n
y
.
c
o
m
Li
c
e
n
s
e
N
u
m
b
e
r
:
F
-
0
1
1
5
10/30/2025
T:
\
P
r
o
j
e
c
t
s
\
N
e
w
_
H
a
n
o
v
e
r
_
C
o
u
n
t
y
-
3
5
1
4
\
A
-
H
o
l
l
y
S
h
e
l
t
e
r
B
u
s
i
n
e
s
s
\
_
C
A
D
D
\
S
h
e
e
t
S
e
t
s
\
H
o
l
l
y
S
h
e
l
t
e
r
P
u
m
p
S
t
a
t
i
o
n
\
3
5
1
4
-
A
_
E
-
3
.
0
E
_
S
H
T
S
.
d
w
g
HB
O
U
R
N
E
10
/
3
0
/
2
0
2
5
4
:
0
6
P
M
EL
E
C
T
R
I
C
A
L
D
E
T
A
I
L
S
E-3.1
HMB
HMB
HMB
PERMITTING
ISSUED FOR:
DATE: 11/2025
DRAWN BY:
CHECKED BY:
PROJECT NO.:
DESIGNED BY:
3514-A
FINAL
DRAWING
FOR REVIEW
PURPOSES ONLY
NOT RELEASED FOR
CONSTRUCTION
NO
R
T
H
C
A
R
O
L
I
N
A
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
HO
L
L
Y
S
H
E
L
T
E
R
B
U
S
I
N
E
S
S
P
A
R
K
RE
V
I
S
I
O
N
S
12
0
N
o
r
t
h
B
o
y
l
a
n
A
v
e
n
u
e
· R
a
l
e
i
g
h
,
N
C
2
7
6
0
3
-
1
4
2
3
(9
1
9
)
8
2
8
-
0
5
3
1
· t
h
e
w
o
o
t
e
n
c
o
m
p
a
n
y
.
c
o
m
Li
c
e
n
s
e
N
u
m
b
e
r
:
F
-
0
1
1
5
10/30/2025
T:
\
P
r
o
j
e
c
t
s
\
N
e
w
_
H
a
n
o
v
e
r
_
C
o
u
n
t
y
-
3
5
1
4
\
A
-
H
o
l
l
y
S
h
e
l
t
e
r
B
u
s
i
n
e
s
s
\
_
C
A
D
D
\
S
h
e
e
t
S
e
t
s
\
H
o
l
l
y
S
h
e
l
t
e
r
P
u
m
p
S
t
a
t
i
o
n
\
3
5
1
4
-
A
_
E
-
3
.
0
E
_
S
H
T
S
.
d
w
g
HB
O
U
R
N
E
10
/
3
0
/
2
0
2
5
4
:
0
7
P
M
EL
E
C
T
R
I
C
A
L
D
E
T
A
I
L
S
E-3.2
HMB
HMB
HMB
PERMITTING
ISSUED FOR:
DATE: 11/2025
DRAWN BY:
CHECKED BY:
PROJECT NO.:
DESIGNED BY:
3514-A
FINAL
DRAWING
FOR REVIEW
PURPOSES ONLY
NOT RELEASED FOR
CONSTRUCTION
NO
R
T
H
C
A
R
O
L
I
N
A
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
HO
L
L
Y
S
H
E
L
T
E
R
B
U
S
I
N
E
S
S
P
A
R
K
RE
V
I
S
I
O
N
S
12
0
N
o
r
t
h
B
o
y
l
a
n
A
v
e
n
u
e
· R
a
l
e
i
g
h
,
N
C
2
7
6
0
3
-
1
4
2
3
(9
1
9
)
8
2
8
-
0
5
3
1
· t
h
e
w
o
o
t
e
n
c
o
m
p
a
n
y
.
c
o
m
Li
c
e
n
s
e
N
u
m
b
e
r
:
F
-
0
1
1
5
10/30/2025
FINISHED GRADE
12"
8"
3" MIN. (TYPICAL)
8"
6"
2"4"
18"
GENERATOR ENCLOSURE
FUEL TANK
(CONSTRUCT PAD BASED UPON DIMENSIONS OF EQUIPMENT ACTUALLY USED)
BOLT EQUIPMENT TO PAD AS RECOMMENDED BY EQUIPMENT MANUFACTURER
#6 REBAR 12" O.C.
EACH WAY
1" CHAMFER
3000 PSI CONCRETE
WELDED WIRE FABRIC
(6"x6") W2 x W2
MAINTAIN 2" COVER FROM
THE TOP OF THE CONCRETE
14" -24" #4 REINFORCING BARS
PRIMARY SECONDARY
REQUIRED CLEARANCE
82"
36"36"
84"
36"
120"
61"
17"
6"
12"12"34"24"NOTES:
1.PAD TO BE A MINIMUM OF 5 1/2" THICK.
2.SHADED AREA AROUND PAD INDICATES MINIMUM CLEARANCE
FROM OBSTRUCTIONS.
3.PIT PAD ONLY.
4.COVER BOTTOM OF PIT WITH 6" GRAVEL.
5.E.C. TO INSTALL THE 1" METER CONDUIT IF REQUIRED FROM
THE PUT PAD TO A LOCATION DETERMINED BY UTILITY'S
PROJECT ENGINEER.
6.E.C. TO CONTACT UTILITY ENGINEER TO INSPECT PAD FORMS
PRIOR TO CONCRETE BEING POURED.
7.CONTRACTOR SHALL SUPPLY CONCRETE MIX AS SHOWN IN
THE CONCRETE MIX SPECS. WELDED WIRE FABRIC, #4
REINFORCING BARS AND POUR THE "PIT BOX" PAD.
FINISHED GRADE
FINISHED GRADE
OPEN AREA
OPEN AREA
PRIMARY
SIDE
SECONDARY
SIDE
6"
GRAVEL
6" DIRT
SIDE VIEW
FRONT VIEW
6" MIN.
6" MIN.
6" MIN.6" MIN.
30"
6"
30"
6"
1"C. METER.
SEE NOTE 5.
FINISHED GRADE
24" MIN. COVER
4" MINIMUM, 6" MAXIMUM CONCRETE ENCASEMENT AROUND ALL DUCTS
2" (TYP.)
DUCTBANK WIDTH AND HEIGHT
AS REQUIRED
#4 REINFORCING STEEL (U-BAR)
SPACED EVERY 36" HORIZONTALLY
ALONG LENGTH OF DUCTBANK
FORMWORK, SEE NOTE 5
#4 REINFORCING STEEL SPACED
EVERY 12" AND AT EVERY CORNER
(TYP. 4 SIDES)
TIE (TYP.)
CONDUIT SIZE(S), QUANTITY AND
TYPE AS REQUIRED
CONCRETE ENCASEMENT
AROUND DUCTS (TYP.)
#4 REINFORCING STEEL BARS
DRIVEN INTO SOIL OR SET IN
CONCRETE PAD, SPACED EVERY
72" HORIZONTALLY ALONG
LENGTH OF DUCTBANK
(TYP. EACH SIDE)
2" (TYP.)
15
"
M
I
N
.
L
A
P
SE
E
N
O
T
E
4
CONDUIT SPACER ASSEMBLY,
SIZE AND CONFIGURATION
AS REQUIRED
#4/0 BARE COPPER
GROUNDING CONDUCTOR,
INSTALLED INSIDE
REINFORCING STEEL CAGE
12
"
M
I
N
.
SPACING DEPENDS UPON NUMBER
OF DUCTS AND TYPE OF SPACERS
NOTES:
1.CONCRETE SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH SPECIFICATION
SECTION 03100.
2.REINFORCING STEEL AND TIES SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH
SPECIFICATION SECTION 03100. OVERLAP FOR REINFORCING STEEL SPLICES ALONG THE
DUCTBANK LENGTH SHALL BE 15", MINIMUM.
3.CONDUIT SPACERS ARE REQUIRED IN ACCORDANCE WITH SPECIFICATION SECTION 16135.
HORIZONTAL SPACING OF CONDUIT SPACER ASSEMBLIES ALONG LENGTH OF DUCTBANK SHALL
BE AS SHOWN IN THE TABLE.
4.FOR DUCTBANKS LESS THAN 15" IN HEIGHT, THE LAP SHALL BE THE HEIGHT OF THE DUCTBANK.
5.IN POOR SOIL CONDITIONS, DUCTBANKS SHALL BE FORMED WITH FORMING MATERIALS TO
MAINTAIN 4" OF ENCASEMENT. WHERE SOIL CONDITIONS PERMITAND THE EXCAVATION IS
MAINTAINED FOR A 4" MINIMUM TO 10" MAXIMUM ENCASEMENT, THE FORMWORK CAN BE
OMITTED.
MAX SPACING BETWEEN CONDUIT SPACER
ASSEMBLIES
CONDUIT SIZE SPACING
1"3 FEET
1 1
4" - 2"5 FEET
2 1
2" - 3"6 FEET
3 12" - 5"7 FEET
6"8 FEET
WEST ELEVATION
POLYCARBONATE
INSTRUMENT SUNSHIELD
POWER AND SIGNAL SURGE
PROTECTOR. EQUAL TO EDCO
TYPE "SLAC" WITH NEMA 4X
STAINLESS STEEL
4-20MA SIGNAL CONDUIT
CONCRETE FLOOR
NORTH ELEVATION
120V POWER CONDUIT
120V POWER WP TOGGLE
SWITCH AND RECEPTACLE
GROUND SYSTEM 5/8"x20'
DRIVEN COPPERCLAD ROD
4'-6"
T:
\
P
r
o
j
e
c
t
s
\
N
e
w
_
H
a
n
o
v
e
r
_
C
o
u
n
t
y
-
3
5
1
4
\
A
-
H
o
l
l
y
S
h
e
l
t
e
r
B
u
s
i
n
e
s
s
\
_
C
A
D
D
\
S
h
e
e
t
S
e
t
s
\
H
o
l
l
y
S
h
e
l
t
e
r
P
u
m
p
S
t
a
t
i
o
n
\
3
5
1
4
-
A
_
E
-
3
.
0
E
_
S
H
T
S
.
d
w
g
HB
O
U
R
N
E
10
/
3
0
/
2
0
2
5
4
:
0
7
P
M
GENERATOR PAD DETAIL
SCALE: N.T.S.
1
E-3.3
TYPICAL DUCTBANK DETAIL
SCALE: N.T.S.
4
E-3.3
TRANSFORMER PAD DETAIL
SCALE: N.T.S.
3
E-3.3
POWERED INSTRUMENT INSTALLATION DETAIL
SCALE: N.T.S.
2
E-3.3
EL
E
C
T
R
I
C
A
L
D
E
T
A
I
L
S
E-3.3
HMB
HMB
HMB
PERMITTING
ISSUED FOR:
DATE: 11/2025
DRAWN BY:
CHECKED BY:
PROJECT NO.:
DESIGNED BY:
3514-A
FINAL
DRAWING
FOR REVIEW
PURPOSES ONLY
NOT RELEASED FOR
CONSTRUCTION
NO
R
T
H
C
A
R
O
L
I
N
A
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
HO
L
L
Y
S
H
E
L
T
E
R
B
U
S
I
N
E
S
S
P
A
R
K
RE
V
I
S
I
O
N
S
12
0
N
o
r
t
h
B
o
y
l
a
n
A
v
e
n
u
e
· R
a
l
e
i
g
h
,
N
C
2
7
6
0
3
-
1
4
2
3
(9
1
9
)
8
2
8
-
0
5
3
1
· t
h
e
w
o
o
t
e
n
c
o
m
p
a
n
y
.
c
o
m
Li
c
e
n
s
e
N
u
m
b
e
r
:
F
-
0
1
1
5
10/30/2025
JUMPER SIZED PER NEC
TABLE 250-66 OR 250-28D
SERVICE EQUIPMENT NEUTRAL BAR
SERVICE EQUIPMENT GROUND BAR
MADE-UP GROUND BUS
FIELD INSTALLED
TO DRY TYPE
TRANSFORMER
3/4" x 10'
GROUND ROD
GROUND BUSHING
ON METALLIC
CONDUIT (TYPICAL)
GROUND CONDUCTOR PER
NEC 250-66 (TYPICAL)
GROUND CLAMP TO WATER
MAIN (SUPPLY SIDE)
PROVIDE JUMPER AROUND
WATER VALVE
TO SERVICE EQUIPMENT
ENCLOSURE PER NEC 250-66
FENCEGATEFENCE
COLOR KEYED
COMPRESSION
TAP (TYPICAL)
FLEX BRAID
GROUND GRID
CONNECTOR
6'-0"
10'-0"
NOTES
1.CONNECTORS INSTALLED FOR THE PURPOSE OF BONDING SECTION OF ROUND, SQUARE OR "H" CROSS-SECTION FENCE POSTS
AND TOP RAILS OR FOR GROUNDING AND BONDING FENCE TO THE GROUND GRID SYSTEM SHALL BE OF THE "KEEPER BAR" TYPE.
2.COMPRESSION CONNECTORS SHALL BE OF CAST COPPER CONSTRUCTION WITH MINIMUM CONDUCTIVITY OF 60% I.A.C.S.
3."U" BOLTS AND ASSOCIATED STEEL HARDWARE SHALL BE ZINC PLATED AND CHROMATE COATED TO RESIST CORROSION.
6"
6" MIN.9 3/8"
2 1/2"
MIN.
GROUND
GROUND
10"
6"
#4 @ 10" (TYPICAL)
2 - #3 CONTINUOUS
TIER 22 RATED BOX WITH
9-3/8" DIAMETER x 2" THICK
POLYMER CONCRETE PRECAST
COVER WITH LIFTING HOLE.
CONNECTOR PER
SECTION 26 05 26.03
CLASS A1 CONCRETE COLLAR
(3/4" SLOP AWAY FROM BOX)
TOP OF GRADE
#4 @ 10" (TYPICAL)
2 - #3 CONTINUOUS
AROUND PERIMETER
COMPACTED FILL
#4/0 STRANDED BARE
COPPER CONDUCTOR
CONNECTED TO GROUND
ROD CLUSTER GROUP
#4/0 STRANDED BARE COPPER
GROUND CONDUCTOR TO
GROUND RING
#57 STONE BASE
GROUND ROD PER
SECTION 26 05 26.03
NOTE:
1.PRECAST PULLBOX AND COVER SHALL BE OLDCASTLE
PART NUMBER 09101187 OR APPROVED EQUAL
TABLE 'A' - WORKING CLEARANCES
VOLTAGE TO GROUND, NOMINAL CONDITION 1 2 3
MIN. CLEAR DISTANCE (FT.)
0-150 3 3 3
151-600 3 3 1/2 4
NOTE: THIS INCLUDES BUT IS NOT LIMITED TO PANELBOARDS,
SAFETY SWITCHES, MOTOR STARTERS, JUNCTION BOXES AND
OTHER ELECTRIC EQUIPMENT.
30" OR WIDTH OF EQUIPMENT IF EQUIPMENT IS WIDER THAN
30". DOES NOT HAVE TO BE CENTERED ON THE EQUIPMENT BUT
AT LEAST EVEN WITH ONE EDGE. EQUIPMENT DOOR SHALL BE
ABLE TO OPEN AT LEAST 90 DEGREES.
WHERE THE CONDITIONS ARE AS FOLLOWING:
1.EXPOSED LIVE PARTS ON ONE SIDE AND NO LIVE OR GROUNDED PARTS
ON THE OTHER SIDE OF THE WORKING SPACE, OR EXPOSED LIVE
PARTS ON BOTH SIDES EFFECTIVELY GUARDED BY SUITABLE WOOD OR
OTHER INSULATING MATERIALS. INSULATED WIRE OR INSULATED
BUSBARS OPERATING AT NOT OVER 300 VOLTS SHALL NOT BE
CONSIDERED LIVE PARTS.
2.EXPOSED LIVE PARTS ON ONE SIDE AND GROUNDED PARTS ON THE
OTHER SIDE.
3.EXPOSED LIVE PARTS ON BOTH SIDES OF THE WORK SPACE (NOT
GUARDED AS PROVIDED IN CONDITION 1) WITH THE OPERATOR
BETWEEN.
ALL ELECTRIC EQUIPMENT
NOTE: NO PIPING, DUCTS, OR EQUIPMENT FOREIGN TO THE
ELECTRICAL EQUIPMENT OR ARCHITECTURAL APPURTENANCES
SHALL BE PERMITTED TO BE INSTALLED IN, ENTER, OR PASS
THROUGH THE DEDICATED SPACES SHOWN ABOVE.
6 1/2' MIN.
SEE TABLE 'A'
THIS DISTANCE
NOTE: THIS FIGURE ILLUSTRATES THE WORKING SPACE
IN FRONT OF ELECTRIC EQUIPMENT REQUIRED BY
SECTION 110-26 OF THE NATIONAL ELECTRIC CODE
LIGHT FIXTURE
PANELBOARD
EXCLUSIVELY
DEDICATED
SPACE
STRUCTURAL
CEILING
SUSPENDED
CEILING
WALL
DEDICATED SPACE CONTINUES
THROUGH SUSPENDED CEILING
TO 6 FEET ABOVE EQUIPMENT
OR STRUCTURAL CEILING,
WHICHEVER IS LOWER.
STRUCTURAL
CEILING
SUSPENDED
CEILING
WALL
LIGHT FIXTURE
PANELBOARD
EXCLUSIVELY
DEDICATED
SPACE
EXCLUSIVELY
DEDICATED
SPACE
PANELBOARD
NOTE: THIS FIGURE ILLUSTRATES THE ADDITIONAL
EXCLUSIVELY DEDICATED SPACE REQUIRED OVER AND UNDER
PANELBOARDS FOR CABLES, RACEWAYS, ETC. TO AND FROM
PANELBOARDS REQUIRED BY THE NATIONAL ELECTRICAL CODE.
T:
\
P
r
o
j
e
c
t
s
\
N
e
w
_
H
a
n
o
v
e
r
_
C
o
u
n
t
y
-
3
5
1
4
\
A
-
H
o
l
l
y
S
h
e
l
t
e
r
B
u
s
i
n
e
s
s
\
_
C
A
D
D
\
S
h
e
e
t
S
e
t
s
\
H
o
l
l
y
S
h
e
l
t
e
r
P
u
m
p
S
t
a
t
i
o
n
\
3
5
1
4
-
A
_
E
-
3
.
0
E
_
S
H
T
S
.
d
w
g
HB
O
U
R
N
E
10
/
3
0
/
2
0
2
5
4
:
0
7
P
M
FENCE GROUNDING DETAIL
SCALE: N.T.S.
1
E-3.4
SERVICE GROUNDING DETAIL
SCALE: N.T.S.
3
E-3.4
EL
E
C
T
R
I
C
A
L
D
E
T
A
I
L
S
E-3.4
HMB
HMB
HMB
GROUND ROD TEST WELL DETAIL
SCALE: N.T.S.
2
E-3.4
DEDICATED WORKING SPACE REQUIREMENTS FOR ELECTRICAL EQUIPMENT
SCALE: N.T.S.
4
E-3.04
PERMITTING
ISSUED FOR:
DATE: 11/2025
DRAWN BY:
CHECKED BY:
PROJECT NO.:
DESIGNED BY:
3514-A
FINAL
DRAWING
FOR REVIEW
PURPOSES ONLY
NOT RELEASED FOR
CONSTRUCTION
NO
R
T
H
C
A
R
O
L
I
N
A
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
HO
L
L
Y
S
H
E
L
T
E
R
B
U
S
I
N
E
S
S
P
A
R
K
RE
V
I
S
I
O
N
S
12
0
N
o
r
t
h
B
o
y
l
a
n
A
v
e
n
u
e
· R
a
l
e
i
g
h
,
N
C
2
7
6
0
3
-
1
4
2
3
(9
1
9
)
8
2
8
-
0
5
3
1
· t
h
e
w
o
o
t
e
n
c
o
m
p
a
n
y
.
c
o
m
Li
c
e
n
s
e
N
u
m
b
e
r
:
F
-
0
1
1
5
PERMITTING
ISSUED FOR:
DATE: 11/2025
DRAWN BY:
CHECKED BY:
PROJECT NO.:
DESIGNED BY:
3514-A
FINAL
DRAWING
FOR REVIEW
PURPOSES ONLY
NOT RELEASED FOR
CONSTRUCTION
NO
R
T
H
C
A
R
O
L
I
N
A
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
NE
W
H
A
N
O
V
E
R
C
O
U
N
T
Y
HO
L
L
Y
S
H
E
L
T
E
R
B
U
S
I
N
E
S
S
P
A
R
K
RE
V
I
S
I
O
N
S
12
0
N
o
r
t
h
B
o
y
l
a
n
A
v
e
n
u
e
· R
a
l
e
i
g
h
,
N
C
2
7
6
0
3
-
1
4
2
3
(9
1
9
)
8
2
8
-
0
5
3
1
· t
h
e
w
o
o
t
e
n
c
o
m
p
a
n
y
.
c
o
m
Li
c
e
n
s
e
N
u
m
b
e
r
:
F
-
0
1
1
5
10/30/2025