Loading...
HomeMy WebLinkAboutPlan Set 91-98E-2.1 HMB HMB HMB PUM P S T A T I O N C O N T R O L R I S E R D I A G R A M , CO N D U I T A N D W I R E S C H E D U L E S PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ E - 2 . 0 E _ S H T S . d w g HB O U R N E 10 / 3 0 / 2 0 2 5 3 : 3 1 P M RTU PANEL - CONTROL RISER DIAGRAM SCALE: NTS 2 E-2.1 LE 1 LIT 1 C-1000 FE 1 FIT 1 EFFLUENT FLOW SP-1 RVSS SP-2 RVSS LSHH 1 TO ANTENNA WET WELL LEVEL RTU-1 GEN-1 ATS-1 C-1002 C-1008 C-1009 C-1017 C-1021SUBMERSIBLE PUMP NO.1 RVSS SUBMERSIBLE PUMP NO.2 RVSS GENERATOR CONTROL PANEL AUTOMATIC TRANSFER SWITCH PUMP CONTROL PANEL PCP-1 C-1012 LS-1 VALVE VAULT CHECK VALVE LIMIT SWITCH C-1006 C-1007 C-1004 C-1005 LSH 3 LSH 2 LSH 1 LSL 1 WET WELL FLOAT SWITCHES C-1020 C-1003C-1001 TERMINAL CABINET TC-1 C-1013 C-1018 P-1031 120V FROM MPC-1 P-1036 120V FROM MPC-1 C-1022 ODOR CONTROL (FUTURE) C-1019 ALARM LIGHT AND HORN C-1015 C-1014 10/30/2025 T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ E - 3 . 0 E _ S H T S . d w g HB O U R N E 10 / 3 0 / 2 0 2 5 4 : 0 6 P M EL E C T R I C A L D E T A I L S E-3.0 HMB HMB HMB NOTE: 1.CFPUA STANDARD DETAILS SHALL BE MODIFIED SO THAT 480V, 3 PHASE COMPONENTS WILL BE PROVIDED BY SEPARATE EXTERNAL ELECTRICAL EQUIPMENT AND ONLY BE SUPPLIED WITH 120VAC. 2.PCP SHALL BE MODIFIED TO PROVIDE CONTROL SIGNALS TO 3 EXTERNAL PUMP MOTOR CONTROLLERS. PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 10/30/2025 T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ E - 3 . 0 E _ S H T S . d w g HB O U R N E 10 / 3 0 / 2 0 2 5 4 : 0 6 P M EL E C T R I C A L D E T A I L S E-3.1 HMB HMB HMB PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 10/30/2025 T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ E - 3 . 0 E _ S H T S . d w g HB O U R N E 10 / 3 0 / 2 0 2 5 4 : 0 7 P M EL E C T R I C A L D E T A I L S E-3.2 HMB HMB HMB PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 10/30/2025 FINISHED GRADE 12" 8" 3" MIN. (TYPICAL) 8" 6" 2"4" 18" GENERATOR ENCLOSURE FUEL TANK (CONSTRUCT PAD BASED UPON DIMENSIONS OF EQUIPMENT ACTUALLY USED) BOLT EQUIPMENT TO PAD AS RECOMMENDED BY EQUIPMENT MANUFACTURER #6 REBAR 12" O.C. EACH WAY 1" CHAMFER 3000 PSI CONCRETE WELDED WIRE FABRIC (6"x6") W2 x W2 MAINTAIN 2" COVER FROM THE TOP OF THE CONCRETE 14" -24" #4 REINFORCING BARS PRIMARY SECONDARY REQUIRED CLEARANCE 82" 36"36" 84" 36" 120" 61" 17" 6" 12"12"34"24"NOTES: 1.PAD TO BE A MINIMUM OF 5 1/2" THICK. 2.SHADED AREA AROUND PAD INDICATES MINIMUM CLEARANCE FROM OBSTRUCTIONS. 3.PIT PAD ONLY. 4.COVER BOTTOM OF PIT WITH 6" GRAVEL. 5.E.C. TO INSTALL THE 1" METER CONDUIT IF REQUIRED FROM THE PUT PAD TO A LOCATION DETERMINED BY UTILITY'S PROJECT ENGINEER. 6.E.C. TO CONTACT UTILITY ENGINEER TO INSPECT PAD FORMS PRIOR TO CONCRETE BEING POURED. 7.CONTRACTOR SHALL SUPPLY CONCRETE MIX AS SHOWN IN THE CONCRETE MIX SPECS. WELDED WIRE FABRIC, #4 REINFORCING BARS AND POUR THE "PIT BOX" PAD. FINISHED GRADE FINISHED GRADE OPEN AREA OPEN AREA PRIMARY SIDE SECONDARY SIDE 6" GRAVEL 6" DIRT SIDE VIEW FRONT VIEW 6" MIN. 6" MIN. 6" MIN.6" MIN. 30" 6" 30" 6" 1"C. METER. SEE NOTE 5. FINISHED GRADE 24" MIN. COVER 4" MINIMUM, 6" MAXIMUM CONCRETE ENCASEMENT AROUND ALL DUCTS 2" (TYP.) DUCTBANK WIDTH AND HEIGHT AS REQUIRED #4 REINFORCING STEEL (U-BAR) SPACED EVERY 36" HORIZONTALLY ALONG LENGTH OF DUCTBANK FORMWORK, SEE NOTE 5 #4 REINFORCING STEEL SPACED EVERY 12" AND AT EVERY CORNER (TYP. 4 SIDES) TIE (TYP.) CONDUIT SIZE(S), QUANTITY AND TYPE AS REQUIRED CONCRETE ENCASEMENT AROUND DUCTS (TYP.) #4 REINFORCING STEEL BARS DRIVEN INTO SOIL OR SET IN CONCRETE PAD, SPACED EVERY 72" HORIZONTALLY ALONG LENGTH OF DUCTBANK (TYP. EACH SIDE) 2" (TYP.) 15 " M I N . L A P SE E N O T E 4 CONDUIT SPACER ASSEMBLY, SIZE AND CONFIGURATION AS REQUIRED #4/0 BARE COPPER GROUNDING CONDUCTOR, INSTALLED INSIDE REINFORCING STEEL CAGE 12 " M I N . SPACING DEPENDS UPON NUMBER OF DUCTS AND TYPE OF SPACERS NOTES: 1.CONCRETE SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH SPECIFICATION SECTION 03100. 2.REINFORCING STEEL AND TIES SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH SPECIFICATION SECTION 03100. OVERLAP FOR REINFORCING STEEL SPLICES ALONG THE DUCTBANK LENGTH SHALL BE 15", MINIMUM. 3.CONDUIT SPACERS ARE REQUIRED IN ACCORDANCE WITH SPECIFICATION SECTION 16135. HORIZONTAL SPACING OF CONDUIT SPACER ASSEMBLIES ALONG LENGTH OF DUCTBANK SHALL BE AS SHOWN IN THE TABLE. 4.FOR DUCTBANKS LESS THAN 15" IN HEIGHT, THE LAP SHALL BE THE HEIGHT OF THE DUCTBANK. 5.IN POOR SOIL CONDITIONS, DUCTBANKS SHALL BE FORMED WITH FORMING MATERIALS TO MAINTAIN 4" OF ENCASEMENT. WHERE SOIL CONDITIONS PERMITAND THE EXCAVATION IS MAINTAINED FOR A 4" MINIMUM TO 10" MAXIMUM ENCASEMENT, THE FORMWORK CAN BE OMITTED. MAX SPACING BETWEEN CONDUIT SPACER ASSEMBLIES CONDUIT SIZE SPACING 1"3 FEET 1 1 4" - 2"5 FEET 2 1 2" - 3"6 FEET 3 12" - 5"7 FEET 6"8 FEET WEST ELEVATION POLYCARBONATE INSTRUMENT SUNSHIELD POWER AND SIGNAL SURGE PROTECTOR. EQUAL TO EDCO TYPE "SLAC" WITH NEMA 4X STAINLESS STEEL 4-20MA SIGNAL CONDUIT CONCRETE FLOOR NORTH ELEVATION 120V POWER CONDUIT 120V POWER WP TOGGLE SWITCH AND RECEPTACLE GROUND SYSTEM 5/8"x20' DRIVEN COPPERCLAD ROD 4'-6" T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ E - 3 . 0 E _ S H T S . d w g HB O U R N E 10 / 3 0 / 2 0 2 5 4 : 0 7 P M GENERATOR PAD DETAIL SCALE: N.T.S. 1 E-3.3 TYPICAL DUCTBANK DETAIL SCALE: N.T.S. 4 E-3.3 TRANSFORMER PAD DETAIL SCALE: N.T.S. 3 E-3.3 POWERED INSTRUMENT INSTALLATION DETAIL SCALE: N.T.S. 2 E-3.3 EL E C T R I C A L D E T A I L S E-3.3 HMB HMB HMB PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 10/30/2025 JUMPER SIZED PER NEC TABLE 250-66 OR 250-28D SERVICE EQUIPMENT NEUTRAL BAR SERVICE EQUIPMENT GROUND BAR MADE-UP GROUND BUS FIELD INSTALLED TO DRY TYPE TRANSFORMER 3/4" x 10' GROUND ROD GROUND BUSHING ON METALLIC CONDUIT (TYPICAL) GROUND CONDUCTOR PER NEC 250-66 (TYPICAL) GROUND CLAMP TO WATER MAIN (SUPPLY SIDE) PROVIDE JUMPER AROUND WATER VALVE TO SERVICE EQUIPMENT ENCLOSURE PER NEC 250-66 FENCEGATEFENCE COLOR KEYED COMPRESSION TAP (TYPICAL) FLEX BRAID GROUND GRID CONNECTOR 6'-0" 10'-0" NOTES 1.CONNECTORS INSTALLED FOR THE PURPOSE OF BONDING SECTION OF ROUND, SQUARE OR "H" CROSS-SECTION FENCE POSTS AND TOP RAILS OR FOR GROUNDING AND BONDING FENCE TO THE GROUND GRID SYSTEM SHALL BE OF THE "KEEPER BAR" TYPE. 2.COMPRESSION CONNECTORS SHALL BE OF CAST COPPER CONSTRUCTION WITH MINIMUM CONDUCTIVITY OF 60% I.A.C.S. 3."U" BOLTS AND ASSOCIATED STEEL HARDWARE SHALL BE ZINC PLATED AND CHROMATE COATED TO RESIST CORROSION. 6" 6" MIN.9 3/8" 2 1/2" MIN. GROUND GROUND 10" 6" #4 @ 10" (TYPICAL) 2 - #3 CONTINUOUS TIER 22 RATED BOX WITH 9-3/8" DIAMETER x 2" THICK POLYMER CONCRETE PRECAST COVER WITH LIFTING HOLE. CONNECTOR PER SECTION 26 05 26.03 CLASS A1 CONCRETE COLLAR (3/4" SLOP AWAY FROM BOX) TOP OF GRADE #4 @ 10" (TYPICAL) 2 - #3 CONTINUOUS AROUND PERIMETER COMPACTED FILL #4/0 STRANDED BARE COPPER CONDUCTOR CONNECTED TO GROUND ROD CLUSTER GROUP #4/0 STRANDED BARE COPPER GROUND CONDUCTOR TO GROUND RING #57 STONE BASE GROUND ROD PER SECTION 26 05 26.03 NOTE: 1.PRECAST PULLBOX AND COVER SHALL BE OLDCASTLE PART NUMBER 09101187 OR APPROVED EQUAL TABLE 'A' - WORKING CLEARANCES VOLTAGE TO GROUND, NOMINAL CONDITION 1 2 3 MIN. CLEAR DISTANCE (FT.) 0-150 3 3 3 151-600 3 3 1/2 4 NOTE: THIS INCLUDES BUT IS NOT LIMITED TO PANELBOARDS, SAFETY SWITCHES, MOTOR STARTERS, JUNCTION BOXES AND OTHER ELECTRIC EQUIPMENT. 30" OR WIDTH OF EQUIPMENT IF EQUIPMENT IS WIDER THAN 30". DOES NOT HAVE TO BE CENTERED ON THE EQUIPMENT BUT AT LEAST EVEN WITH ONE EDGE. EQUIPMENT DOOR SHALL BE ABLE TO OPEN AT LEAST 90 DEGREES. WHERE THE CONDITIONS ARE AS FOLLOWING: 1.EXPOSED LIVE PARTS ON ONE SIDE AND NO LIVE OR GROUNDED PARTS ON THE OTHER SIDE OF THE WORKING SPACE, OR EXPOSED LIVE PARTS ON BOTH SIDES EFFECTIVELY GUARDED BY SUITABLE WOOD OR OTHER INSULATING MATERIALS. INSULATED WIRE OR INSULATED BUSBARS OPERATING AT NOT OVER 300 VOLTS SHALL NOT BE CONSIDERED LIVE PARTS. 2.EXPOSED LIVE PARTS ON ONE SIDE AND GROUNDED PARTS ON THE OTHER SIDE. 3.EXPOSED LIVE PARTS ON BOTH SIDES OF THE WORK SPACE (NOT GUARDED AS PROVIDED IN CONDITION 1) WITH THE OPERATOR BETWEEN. ALL ELECTRIC EQUIPMENT NOTE: NO PIPING, DUCTS, OR EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITECTURAL APPURTENANCES SHALL BE PERMITTED TO BE INSTALLED IN, ENTER, OR PASS THROUGH THE DEDICATED SPACES SHOWN ABOVE. 6 1/2' MIN. SEE TABLE 'A' THIS DISTANCE NOTE: THIS FIGURE ILLUSTRATES THE WORKING SPACE IN FRONT OF ELECTRIC EQUIPMENT REQUIRED BY SECTION 110-26 OF THE NATIONAL ELECTRIC CODE LIGHT FIXTURE PANELBOARD EXCLUSIVELY DEDICATED SPACE STRUCTURAL CEILING SUSPENDED CEILING WALL DEDICATED SPACE CONTINUES THROUGH SUSPENDED CEILING TO 6 FEET ABOVE EQUIPMENT OR STRUCTURAL CEILING, WHICHEVER IS LOWER. STRUCTURAL CEILING SUSPENDED CEILING WALL LIGHT FIXTURE PANELBOARD EXCLUSIVELY DEDICATED SPACE EXCLUSIVELY DEDICATED SPACE PANELBOARD NOTE: THIS FIGURE ILLUSTRATES THE ADDITIONAL EXCLUSIVELY DEDICATED SPACE REQUIRED OVER AND UNDER PANELBOARDS FOR CABLES, RACEWAYS, ETC. TO AND FROM PANELBOARDS REQUIRED BY THE NATIONAL ELECTRICAL CODE. T: \ P r o j e c t s \ N e w _ H a n o v e r _ C o u n t y - 3 5 1 4 \ A - H o l l y S h e l t e r B u s i n e s s \ _ C A D D \ S h e e t S e t s \ H o l l y S h e l t e r P u m p S t a t i o n \ 3 5 1 4 - A _ E - 3 . 0 E _ S H T S . d w g HB O U R N E 10 / 3 0 / 2 0 2 5 4 : 0 7 P M FENCE GROUNDING DETAIL SCALE: N.T.S. 1 E-3.4 SERVICE GROUNDING DETAIL SCALE: N.T.S. 3 E-3.4 EL E C T R I C A L D E T A I L S E-3.4 HMB HMB HMB GROUND ROD TEST WELL DETAIL SCALE: N.T.S. 2 E-3.4 DEDICATED WORKING SPACE REQUIREMENTS FOR ELECTRICAL EQUIPMENT SCALE: N.T.S. 4 E-3.04 PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 PERMITTING ISSUED FOR: DATE: 11/2025 DRAWN BY: CHECKED BY: PROJECT NO.: DESIGNED BY: 3514-A FINAL DRAWING FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION NO R T H C A R O L I N A NE W H A N O V E R C O U N T Y NE W H A N O V E R C O U N T Y HO L L Y S H E L T E R B U S I N E S S P A R K RE V I S I O N S 12 0 N o r t h B o y l a n A v e n u e · R a l e i g h , N C 2 7 6 0 3 - 1 4 2 3 (9 1 9 ) 8 2 8 - 0 5 3 1 · t h e w o o t e n c o m p a n y . c o m Li c e n s e N u m b e r : F - 0 1 1 5 10/30/2025