Loading...
HomeMy WebLinkAbout3411 Merchant Court - Site PlanM E R C H A N T C O U R T ( P R I V A T E R O W ) S I T E NORTHCHAS E P A R K W A Y N E (PRIVATE R O W ) MurvilleSoils VICINITY AND SOILS MAP SCALE: 1" = 200' SITE AND LANDSCAPE PLAN SHEET DESCRIPTIONINDEX CIVIL SHEET LIST CS-100 1 2 3 PG. COVER COVER SHEET DECEMBER 2025 NEW HANOVER COUNTY TRC DESIGN DOCUMENTS 3411 MERCHANT COURT BUILDING COVER 1 COVER SHEET NA NOR T H CAROLINA JAME B A NC H S M PRO FESSION ENGIN E E R SEAL AL S R ITH 034354 REVISION NO. PROJ. NO.25500.DLD OF: SHEET: DATE: SCALE: DRAWN BY: 34 1 1 M E R C H A N T C O U R T , W I L M I N G T O N , N C 2 8 4 0 5 TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F D O G W O O D L D , P L L C A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E P T B Y A G R E E M E N T W I T H D O G W O O D L D , P L L C . PR O V E R B S 1 6 : 3 C O M M I T Y O U R W O R K S T O T H E L O R D A N D Y O U R P L A N S W I L L B E E S T A B L I S H E D . JBS TH E C A M P G R O U P , L L C 31 1 J U D G E S R D , S U I T E 1 2 F WI L M I N G T O N , N C 2 8 4 0 5 P-2785 12.03.25 5 34 1 1 M E R C H A N T C O U R T CO M M E R C I A L B U I L D I N G FINAL PLAN NOT FOR CONSTRUCTION 04/16/20 GRADING, DRAINAGE, AND UTILITY PLANCUG-100 UTILITY NOTICE REQUIRED ALL EXISTING UNDERGROUND UTILITIES SHALL BE PHYSICALLY LOCATED PRIOR TO THE BEGINNING OF ANY CONSTRUCTION IN THE VICINITY OF SAID UTILITIES. CONTRACTORS SHALL NOTIFY OPERATORS WHO MAINTAIN UNDERGROUND UTILITY LINES IN THE AREA OF PROPOSED EXCAVATION AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN TEN WORKING DAYS PRIOR TO COMMENCEMENT OF EXCAVATION OR DEMOLITION. CONTRACTORS SHALL CONTACT OVERHEAD ELECTRIC PROVIDER TO COMPLY WITH FEDERAL OSHA 1910.333 MINIMUM APPROACH DISTANCE TO ENERGIZED POWERLINES AND OSH 29 CFR 1926.1407-1411 MUST BE FOLLOWED. Know what's below.before you dig.Call R UTILITY CONTACTS AND AUTHORITIES HAVING JURISDICTION NHC COUNTY FIRE-RESCUE NON-EMERGENCY 910-798-7420NEW HANOVER COUNTY PLANNING AND ZONING 910-798-5151 NCDEQ LAND QUALITY STORMWATER-EROSION 910-796-7215NHC ENGINEERING STORMWATER-EROSION 910-798-7139 CAPE FEAR PUBLIC UTILITY ENGINEERING 910-332-6550DUKE ENERGY ELECTRIC CUSTOMER 1-800-452-2777 AT&T ENGINEERING 910-341-7664SPECTRUMENGINEERING910-763-4638 PIEDMONT NATURAL GAS ENGINEERING 910-350-2242 4-5 CIVIL DETAILS SHEETS CD100 - CD101 LAND SURVEYOR -SUBDIVISION PLATPB 76 PG 313 C.O. 31 ' ± B U F F E R 30' 25 ' F R O N T S E T B A C K 24' 1-STORY BUILDING 7,400 SF 20' 37' 40' 14' 15' N 75°37'38" E 290.01' (TOTAL) SS SS SS SS SS SS SS SS SS SS SS S 1 4 ° 2 2 ' 2 2 " E 2 3 8 . 8 3 ' N 1 3 ° 1 1 ' 1 1 " W N 1 4 ° 2 2 ' 2 3 " W 90 . 2 8 ' N 1 4 ° 2 2 ' 2 2 " W 2 3 8 . 8 3 ' N 1 4 ° 2 2 ' 2 2 " W 9 5 . 7 1 ' 30.00' 30.00' N 75°37'38" E 290.12' (TOTAL) S 1 4 ° 2 2 ' 2 2 " E 9 5 . 7 1 ' L1 L2 T T T G 36 33 33 32 34 34 35 35 36 37 3 7 38 36 33 32 32 32 33 33 35 35 36 38 37 38 36 37 36 WEST SHORE HOMES WAREHOUSE AND OFFICE 37 36 W 24 . 1 4 ' W W W W W W W W W W W FFE: 39.30 3 5 NOR T H CAROLINA JAME B A NC H S M PRO FESSION ENGIN E E R SEAL AL S R ITH 034354 REVISION NO. PROJ. NO.25500.DLD OF: SHEET: DATE: SCALE: DRAWN BY: 34 1 1 M E R C H A N T C O U R T , W I L M I N G T O N , N C 2 8 4 0 5 TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F D O G W O O D L D , P L L C A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E P T B Y A G R E E M E N T W I T H D O G W O O D L D , P L L C . PR O V E R B S 1 6 : 3 C O M M I T Y O U R W O R K S T O T H E L O R D A N D Y O U R P L A N S W I L L B E E S T A B L I S H E D . JBS TH E C A M P G R O U P , L L C 31 1 J U D G E S R D , S U I T E 1 2 F WI L M I N G T O N , N C 2 8 4 0 5 P-2785 12.03.25 5 34 1 1 M E R C H A N T C O U R T CO M M E R C I A L B U I L D I N G FINAL PLAN NOT FOR CONSTRUCTION 04/16/20 CS100 2 SITE AND LANDSCAPE PLAN 1" = 20' 0 10 20 40 80 S C A L E: 1" = 20' G R A P H I C S C A L E NA D 8 3 ( 2 0 1 1 ) (N C G R I D ) CC PARKING ISLAND TREECC PARKING ISLAND TREE CC PARKING ISLAND TREE ACCESSIBLESPACES, RAMP, & SIGNAGE(SEE DETAILS) MV STREET TREES FG SHRUBS FG SHRUBS PROPERTY LINE WHEEL STOPS, TYP. (SEE DETAILS) 24" CURB AND GUTTER (SEE DETAILS) 24" CURB AND GUTTER CONNECT TO EXISTING 24" CURB AND GUTTER CONNECT TO EXISTING (DG 32.30) (TOP 35.91) (TOP 36.28) (DG 31.44) (TOP 36.07) (TOP 34.95) C.O. 25 ' F R O N T S E T B A C K 1-STORY BUILDING 7,400 SF (EP35.01) (BC35.80) FFE: 38.30 DROP INLET RIM 35.58' 15" RCP INV. 31.98' SSMH RIM 36.33' INV. OUT 29.72' SSMH RIM 36.01 CL INV. 29.60' DROP INLET RIM 34.58' 15" RCP IN/OUT 31.18' DROP INLET RIM 34.90' 15" RCP IN 31.45' 24" RCP OUT 31.45'15" RCP 15" RCP 24" RC P 15 " R C P 1 5 " R C P DROP INLET RIM 34.52' INV. IN/OUT 31.07' SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS N 1 3 ° 1 1 ' 1 1 " W 23 8 . 8 8 ' N 1 4 ° 2 2 ' 2 3 " W 90 . 2 8 ' 30.00' 30.00' N 75°37'38" E 290.12' (TOTAL) L1 L2 24" RC P CO T T T G 36 33 33 32 34 34 35 35 36 37 3 7 38 36 33 32 32 32 33 33 35 35 36 39 38 38 37 38 36 37 36 SS SS SS SS SS SS SS SS SS WEST SHORE HOMES WAREHOUSE AND OFFICE WATER METER WATER VALVE DI RIM: 36.23' 37 37 36 W 24 . 1 4 ' WATER METER W UNK STORM UN K S T O R M UN K S T O R M ROOF DRAIN PIPE ROOF DRAIN PIPE RO O F D R A I N P I P E W W W W W W W W W W W W W W FFE: 39.30 3 5 TC 38.70 EP 38.30 EP 38.30RIM=36.75 INV=33.50 15" HP PIPE 68 LF @ 0.50% RIM=36.75 INV=32.90 TC 38.00 EP 37.50 15" HP PIPE 45 LF @ 0.78% 6" ROOF DRAIN PIPE TO BOX 6" ROOF DRAIN PIPE TO BOX TC 38.30 EP 37.80 EP 38.10 TC 38.30 EP 37.80 EP 38.30 PG 37.80 PG 37.40 EP 37.90 PG 37.40 (EP35.01)EP38.50 EXPOSED FOUNDATION EP38.50 EXPOSED FOUNDATION EP 37.80 TC 37.30 EP 36.80 TC 36.40 EP 35.90 TC 36.40 EP 35.90 TC 36.90 EP 36.40 TC 37.80 EP 37.30 NOR T H CAROLINA JAME B A NC H S M PRO FESSION ENGIN E E R SEAL AL S R ITH 034354 REVISION NO. PROJ. NO.25500.DLD OF: SHEET: DATE: SCALE: DRAWN BY: 34 1 1 M E R C H A N T C O U R T , W I L M I N G T O N , N C 2 8 4 0 5 TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F D O G W O O D L D , P L L C A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E P T B Y A G R E E M E N T W I T H D O G W O O D L D , P L L C . PR O V E R B S 1 6 : 3 C O M M I T Y O U R W O R K S T O T H E L O R D A N D Y O U R P L A N S W I L L B E E S T A B L I S H E D . JBS TH E C A M P G R O U P , L L C 31 1 J U D G E S R D , S U I T E 1 2 F WI L M I N G T O N , N C 2 8 4 0 5 P-2785 12.03.25 5 34 1 1 M E R C H A N T C O U R T CO M M E R C I A L B U I L D I N G FINAL PLAN NOT FOR CONSTRUCTION 04/16/20 CUG100 3 GRADING, DRAINAGE, AND UTILITY 1" = 20' 0 10 20 40 80 S C A L E: 1" = 20' G R A P H I C S C A L E NA D 8 3 ( 2 0 1 1 ) (N C G R I D ) PG = PROPOSED GRADE (GROUND) (EG) = EXISTING GRADE EP = EDGE OF PAVEMENT EC = EDGE OF CONCRETE SW = TOP OF SIDEWALK BC/TC = TOP OF CURB ELEVATION GRV = GRAVEL PARKING RIM =CENTER OF GRATECI = CATCH BASIN DI =DROP INLET YI =YARD INLET MH =STORM MANHOLE CL =CENTERLINE INV =INVERT C/O =TOP OF CLEANOUT (EG)=EXISTING ELEVATIONS, TYP. SPOT GRADE LEGEND: LEGEND: WATER LINE SANITARY SEWER LINE SANITARY SEWER LATERAL/SERVICE STORM DRAIN LINE ROOF DRAIN LINE PROPOSED CONTOURS PROPOSED SETBACKS PROPOSED BUFFERS/EASEMENTS PROPOSED SWALE/DITCH SS SS W W W C.O. 20 SANITARY SEWER CLEANOUT SANITARY SEWER MANHOLE FIRE HYDRANT ASSEMBLY WATER METERS/BACKFLOW ENCLOSURES VALVES/APPURTENANCES >>>> PROPOSED CONTOURS20 EXISTING CONTOURS20 SS PROPOSED RIGHT OF WAY GENERAL EARTHWORK NOTES: 1. THE CONTRACTOR IS REQUIRED TO STRIP TOPSOIL AND ANY UNSUITABLE MATERIAL AND PROVIDE CUT/FILL OPERATIONS TO PROVIDE A COMPACTED CONTROLLED PAVEMENT SUBGRADE, AND BUILDING PAD IN ACCORDANCE WITH THE SUBSURFACE GEOTECHNICAL EXPLORATION AND TECHNICAL SPECIFICATIONS. 2.THE CIVIL ENGINEER CAN RECOMMEND A TYPICAL PAVEMENT SECTION UPON REQUEST, BUT THE RESPONSIBILITY OF PAVEMENT TESTING AND SECTION SHALL BE IN ACCORDANCE WITH FIELD CONDITIONS AND GEOTECHNICAL SPECIFICATIONS. 3. THE CONTRACTOR IS TO ESTABLISH AND CHECK ALL HORIZONTAL AND VERTICAL CONTROLS TO BE USED WITH THE PROJECT. CONTRACTOR SHALL EMPLOY A PROFESSIONAL SURVEYOR TO PERFORM SITE IMPROVEMENT STAKEOUT(S). 3.ANYTIME WORK IS PERFORMED OFF-SITE OR WITHIN AN EXISTING EASEMENT, THE CONTRACTOR IS TO NOTIFY THE HOLDER OF SAID EASEMENT AND TO FOLLOW ANY GUIDELINES OR STANDARDS WHICH ARE ASSOCIATED WITH OR REFERENCED IN THE RECORDED EASEMENT. CONTRACTOR SHALL EMPLOY PROFESSIONAL SURVEYOR TO PERFORM LOCATION OF EASEMENTS AS NEEDED. 5. CIVIL SITE PLANS DO NOT REPRESENT ACCURACY OR PIPE PENETRATION LOCATIONS OF ALL STRUCTURES. CONTRACTOR AND OWNER SHALL REFER TO ARCHITECTURAL DRAWINGS FOR ALL BUILDING DIMENSIONS AND DETAILS. GRADING AND DRAINAGE NOTES: 1.)STORMWATER SYSTEM MAINTENANCE IS THE RESPONSIBILITY OF THE PROPERTY OWNER, INCLUDING PIPES, STRUCTURES, AND STORMWATER CONTROL MEASURES AS PERMITTED WITH THE STATE OR LOCAL JURISDICTION. 2.)ALL IMPERVIOUS MUST DRAIN TO THE DESIGNED STORMWATER SYSTEM UNLESS SHOWN OTHERWISE. 3.)BUILDINGS SHALL DIVERT ROOF DRAINAGE TO STORMWATER COLLECTION SYSTEM. CONTRACTOR, BUILDERS, AND OWNERS ARE RESPONSIBLE FOR COORDINATING ROOF DRAINAGE PIPING IN ADVANCE OR ORDERING FINAL STORM DRAINAGE. REF. CIVIL OR ARCHITECT DETAILS FOR TYPICAL DOWNSPOUT DETAILS AND CONNECTIONS. 4.)REFERENCE GENERAL NOTES SHEET FOR GRADING, DRAINAGE AND EROSION CONTROL NOTES AND DETAILS. TECHNICAL SPECIFICATIONS ARE NOT PROVIDED SEPARATELY BUT INCLUDED HEREIN THESE DESIGN DOCUMENTS FOR REFERENCE. ANY DISCREPANCIES SHALL BE PRESENTED TOTHE ENGINEER PRIOR TO CHANGING THE WORK.CONSTRUCTION SHALL BE IN ACCORDANCE WITH PENDERCOUNTY AND THE TOWN OF SURF CITY BUILDINGINSPECTIONS. 5.)GEOTECHNICAL TESTING SHALL BE PERFORMED ON-SITE BY ATHIRD-PARTY GEOTECHNICAL ENGINEER IN ORDER TOCONFIRM SUITABILITY OF SOILS AND SUBGRADE MATERIALAND SET THE MINIMUM COMPACTION VALUES IN FILL AREAS,UTILITY TRENCHES, PAVEMENT, AND BUILDING PADS.CONTRACTOR SHALL STRIP TOPSOIL AND ANY UNSUITALBEMATERIAL AND PROVIDE CUT/FILL OPERATIONS TO PROVIDE ACOMPACTED CONTROLLED SUBGRADE, IN ACCORDANCE WITHTHE GEOTECHNICAL ENGINEER. WATER AND SEWER TAPS: 1" SERVICE AND WM AND RPZ ENCLOSURE AND 6" SEWER SERVICE 18" INSIDE EASEMENT 1" CORP. STOP TAP (REF. CFPUA SPECS) REF. BLDG PLANS FOR PLUMBING CONNECTIONS TAPER DOWN SIDEWALK 1:12 MAX SLOPE (TYP) WALK 5. 0 ' M I N . 5' MIN. ISOMETRIC FLUSH WITH PARKING LOT SURFACE 2% M A X . SL O P E DETECTABLE WARNING PADSBEFORE VEHICULAR TRAVEL ACCESS 1:12 MAX SLOPE (TYP) RAISED SIDEWALK OR TAPERED UP TO EXISTINGHARDSCAPE/SIDEWALK PAINT MARKINGSPER ADA GUIDELINES. PAINT MARKINGS PER ADA GUIDELINES. OPTIONAL WHEEL STOPS. SECURELY ATTACH WHEEL STOPS INTO PAVEMENT WITH NOT LESS THAN TWO GALVANIZED STEEL DOWELS EMBEDDED IN HOLES CAST INTO WHEEL STOPS. FIRMLYBOND EACH DOWEL TO WHEEL STOP AND TO PAVEMENT. EXTEND UPPER PORTION OFDOWEL 5 INCHES INTO WHEEL STOP AND LOWER PORTION AS NOTED ON THE DRAWINGS INTO PAVEMENT *NOTE: WHEEL STOPS SHALL BE PLACED 2.5' FROM THE END OF THE PARKING STALL STANDARD PRECAST CONCRETE PARKING CHOCK 1'-0'' 6'-0'' 1'-0'' 4" 6" WHEEL STOP NOT TO SCALE NOTES 1. ACCESSIBLE PARKING AND ACCESSIBLE AISLES SHALL NOT EXCEED 2.0% IN SLOPE IN ANY DIRECTION. IF ONLY ONE ACCESS AISLE IS INSTALLED, IT IS TO BE A VAN SIZE. 2. PARKING STALL DIMENSIONING SHALL BE IN ACCORDANCE WITH APPLICABLE GOVERNING AUTHORITY'S AND ADA STANDARDS AND IF DIFFERENT THAN THIS DETAIL SHALL BE THE DIMENSIONING SHOWN ON THE SITE LAYOUT PLAN. 3. GENERAL CONTRACTOR SHALL REFER TO OWNER STANDARD PARKING LOT STRIPING SPECIFICATIONS AND COLORS. 4. CONTRACTOR SHALL USE 4" WIDE WHITE PAINT FOR STRIPING ON ASPHALT PARKING LOTS. 5. CONTRACTOR SHALL USE 4" WIDE YELLOW PAINT FOR STRIPING ON CONCRETE PARKING LOTS. 8'8' SIGN HANDICAP SIGN DETAIL NOTES: 2. 1. POST HOLES SHALL BE FILLED WITH GRANULAR BACKFILL IN 3-INCH TO 4-INCH LIFTS. METAL POST AND ALL HARDWARE SHALL BE GALVANIZED STEEL, ASTM A307-90. 5.TOP EDGE TREATMENT FILM SHALL BE 3" WIDE, CLEAR AND TRANSPARENT WITH A 8. 7. 6. SPACING BETWEEN LINES. ARROWS SHALL BE 5.625" LONG BY 3.75" HIGH. CORNER RADIUS OF SIGNS SHALL BE 2.5" SHALL BE 3.75" HEIGHT AND LOWERCASE LETTERS SHALL BE 2.5" HEIGHT WITH 3.75" SIGN LETTERING SHALL BE NPS MODIFIED CLARENDON TYPEFACE. UPPERCASE LETTERS BY 3M COMPANY. REFLECTIVE FACING MATERIAL SHALL BE SCOTCHLITE HIGH INTENSITY, MANUFACTURED TRANSPARENT FILE #639. SUB-RESISTANT PRESSURE SENSITIVE NON-YELLOWING ADHESIVE, "SKOTCHCAL" 4. 3. WITH ASTM STD B-209. THICKNESS SHALL BE 0.80 INCHES. SIGNS SHALL BE CONSTRUCTED OF ALUMINUM, TYPE 6061-T6 AND IN CONFORMANCE COMPRESSIVE STRENGTH OF 3000 PSI. CONCRETE FOR FOOTING SHALL BE PORTLAND CEMENT AND HAVE A MINIMUM THOROUGHLY HAND TAMP EACH LIFT AND CROWN BACKFILL AT TOP TO SHED WATER. 9.MOUNT ON BUILDING OR METAL POST AS DIRECTED. NOT TO SCALE 12" PARKING RESERVED $ 250 MAXIMUM PENALTY 7' PAVEMENT/GRASS $ 250 PENALTY MAXIMUM 9" 9" 2" R7-8D12"x9" 6" 18" MUTCD 12"x18"R7-8 R7-8a9"VAN PARKING RESERVED ACCESSIBLE 18" 2" 12"x6" 12" 4" PAINTED LINE (TYP.) 8" DIAM. 1'- 4 " 10 " 1'- 1 0 " 8" 1'-2" 14"R PARKING ACCESSIBLE SPACE DIMENSIONS AND STRIPING DETAILS NOT TO SCALE NOTE: PAVEMENT SECTION SHALL BE VERIFIED WITHGEOTECHNICAL ENGINEER OTHERWISE SECTION IS TYPICAL FOR RESIDENTIAL STREETS IN THE AREA, BUT ANY PAVEMENT FAILURES MUST BE AT THEOWNER'S EXPENSE. 6" - AGGREGATE BASE COURSE COMPACTED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT COMPACTED SUBGRADE INACCORDANCE WITH THE GEOTECHNICAL REPORT 2.0" - SF9.5C SURFACE IN ACCORDANCE WITH NCDOT SPECIFICATIONS ASPHALT PAVEMENT SECTION NOT TO SCALE GROOVED CONTRACTION 1/2" EXPANSION JOINT- MAX. 50' O.C. & BETWEEN STRUCTURES 4" 5'-0" PLAN VIEW SECTION VIEW 1/4" PER FT. 3000 PSI CONCRETE RAD. 1/8" EXPANSION JOINT 1/2" JOINT CONTRACTION JOINT 1/8'' RADIUS, TYP. DUMMY GROOVE 1/8" 4" 1" 4" or 6"See Plan 6" 3" 45° 4" 9" ASPHALT PAVEMENT 4' TURNDOWN SIDEWALK CONCRETE DETAIL NOT TO SCALE GENERAL CIVIL-SITE NOTES: 1. THE CONTRACTOR IS REQUIRED TO OBTAIN ANY/ALL PERMITS REQUIRED FOR CONSTRUCTION OF THESE PLANS. 2.ALL CONSTRUCTION TO BE IN ACCORDANCE WITH PERMITS ISSUED. 3. THE CONTRACTOR IS TO ESTABLISH AND CHECK ALL HORIZONTAL AND VERTICAL CONTROLS TO BE USED WITH THE PROJECT. CONTRACTOR SHALL EMPLOY A PROFESSIONAL SURVEYOR TO PERFORM SITE IMPROVEMENT STAKEOUT(S). 4.ANYTIME WORK IS PERFORMED OFF-SITE OR WITHIN AN EXISTINGEASEMENT, THE CONTRACTOR IS TO NOTIFY THE HOLDER OF SAIDEASEMENT AND TO FOLLOW ANY GUIDELINES OR STANDARDS WHICHARE ASSOCIATED WITH OR REFERENCED IN THE RECORDED EASEMENT.CONTRACTOR SHALL EMPLOY PROFESSIONAL SURVEYOR TO PERFORM LOCATION OF EASEMENTS AS NEEDED. 5. CIVIL SITE PLANS DO NOT REPRESENT ACCURACY OR PIPE PENETRATION LOCATIONS OF ALL STRUCTURES. CONTRACTOR ANDOWNER SHALL REFER TO ARCHITECTURAL DRAWINGS FOR ALL BUILDINGDIMENSIONS AND DETAILS. GENERAL CONTRACT NOTES: 1. REASONABLE CARE HAS BEEN EXERCISED IN SHOWINGTHE LOCATION OF EXISTING UTILITIES ON THE PLANS. THEEXACT LOCATION OF ALL EXISTING UTILITIES IS NOTKNOWN IN ALL CASES. THE CONTRACTOR SHALL EXPLORE THE AREA AHEAD OF DITCHING OPERATIONS BY OBSERVATIONS, ELECTRONIC DEVICES, HAND DIGGING AND BY PERSONAL CONTACT WITH THE UTILITY COMPANIES. IN ORDER TO LOCATE EXISTING UTILITIES IN ADVANCE OF TRENCHING OPERATIONS SO AS TOELIMINATE OR MINIMIZE DAMAGE TO EXISTING UTILITIES.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALLCOSTS RESULTING FROM ANY DAMAGE TO THE EXISTINGUTILITY LINES INCLUDING LOSS OF UTILITY REVENUES.CONTRACTOR SHALL ARRANGE FOR TEMPORARYSUPPORT OF EXISTING UTILITIES, SUCH AS POLES, CONDUITS, FIBER OPTIC CABLES, TELEPHONE CABLES, WATER LINES, ETC. 2. CONTRACTOR SHALL COMPLY WITH THE LATESTREVISIONS AND INTERPRETATIONS OF THE DEPARTMENTOF LABOR SAFETY AND HEALTH REGULATIONS FORCONSTRUCTION PROMULGATED UNDER THEOCCUPATIONAL SAFETY AND HEALTH ACT. 3.CONTRACTOR SHALL PLAN AND CONSTRUCT WORK SO AS TO CAUSE MINIMUM INCONVENIENCE TO THE OWNER AND THE PUBLIC. THE CONTRACTOR SHALL PROVIDE, ERECT AND MAINTAIN AT ALL TIMES DURING THE PROGRESS ORTEMPORARY SUSPENSION OF WORK, SUITABLE BARRIERS,FENCES, SIGNS OR OTHER ADEQUATE PROTECTION,INCLUDING FLAGMEN AND WATCHMEN AS NECESSARY TOINSURE THE SAFETY OF THE PUBLIC AS WELL AS THOSEENGAGED IN THE CONSTRUCTION WORK. CONSTRUCTIONSIGNING SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF "CONSTRUCTION AND MAINTENANCE OPERATIONS SUPPLEMENT TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" BY THE USDOT. 4.ANY DISCREPANCY IN THIS PLAN AND ACTUAL FIELDCONDITIONS SHALL BE REPORTED TO THE OWNER PRIORTO START OF CONSTRUCTION. GENERAL CONTRACTORSHALL BE RESPONSIBLE FOR VERIFICATION OF ALLSETBACKS, EASEMENTS AND DIMENSIONS SHOWN HEREON BEFORE BEGINNING CONSTRUCTION. 5.DO NOT SCALE THIS DRAWING AS IT IS A REPRODUCTION AND SUBJECT TO DISTORTION. 6.IF DEPARTURES FROM THE SPECIFICATIONS ORDRAWINGS ARE DEEMED NECESSARY BY THECONTRACTOR, DETAILS OF SUCH DEPARTURES ANDREASONS THEREOF SHALL BE GIVEN TO THE OWNER FOR REVIEW, NO DEPARTURES FROM THE CONTRACT DOCUMENTS SHALL BE MADE WITHOUT THE PERMISSION OF THE OWNER, ENGINEER, AND/OR ARCHITECT. 7.CONTRACTOR SHALL VERIFY LOCATION AND ELEVATIONOF ALL UNDERGROUND UTILITIES. THE LOCATION OF ALLEXISTING UTILITIES ARE NOT NECESSARILY SHOWN ONPLANS AND WHERE SHOWN ARE ONLY APPROXIMATE. THECONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO UNDERGROUND STRUCTURES. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING ALL NON SUBSCRIBING UTILITIES. C A L L NC-811. 8.THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALLINSPECTIONS, CERTIFICATIONS, EQUIPMENT, ETC., THATMAY BE REQUIRED. 9.THE ENGINEER DISCLAIMS ANY ROLE IN THE CONSTRUCTION MEANS AND METHODS ASSOCIATED WITH THE PROJECT AS SET FORTH IN THESE PLANS. 114"R 1"6" 2'-0" 12"R 6" 13 " 6" SPILLING CURB AND GUTTER LIGHT BROOM FINISH 1" CATCHING CURB AND GUTTER 114"R 1"6" 2'-0" PAVEMENT DIMENSION REFERS TO FACE OF CURB UNLESS INDICATED OTHERWISE 12"R 6" 12 " 7" 1" 2 3" PER FT. LIGHT BROOM FINISH 1"R 4" CABC EXTENDED MIN. 6" PAST BACK OF CURB 4" CABC EXTENDED MIN. 6" PAST BACK OF CURB PAVEMENT DIMENSION REFERS TO FACE OF CURB UNLESS INDICATED OTHERWISE 23" PER FT. MIN. 2.5' ELEVATION VIEW PLAN VIEW 2.5' 1-ft SAW CUT (1.5") FOR 1-FT OF EXISTING EDENS LANE. REPAVE OVER 1-FT TO COVER SEAM. EXISTINGEDENS LANE PROPOSEDPRIVATE DRIVEWAY (SEE SECTION THIS SHEET) EDGE TREATMENT FOR ADJACENT ASPHALT NOT TO SCALE CURB RAMP DETAIL (TYPE 2) NOT TO SCALE 24" CURB AND GUTTER (STD. & SPILL) NOT TO SCALE CURB END TAPER DETAIL NOT TO SCALE CURB CD100 4 CIVIL DETAILS NA NOR T H CAROLINA JAME B A NC H S M PRO FESSION ENGIN E E R SEAL AL S R ITH 034354 REVISION NO. PROJ. NO.25500.DLD OF: SHEET: DATE: SCALE: DRAWN BY: 34 1 1 M E R C H A N T C O U R T , W I L M I N G T O N , N C 2 8 4 0 5 TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F D O G W O O D L D , P L L C A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E P T B Y A G R E E M E N T W I T H D O G W O O D L D , P L L C . PR O V E R B S 1 6 : 3 C O M M I T Y O U R W O R K S T O T H E L O R D A N D Y O U R P L A N S W I L L B E E S T A B L I S H E D . JBS TH E C A M P G R O U P , L L C 31 1 J U D G E S R D , S U I T E 1 2 F WI L M I N G T O N , N C 2 8 4 0 5 P-2785 12.03.25 5 34 1 1 M E R C H A N T C O U R T CO M M E R C I A L B U I L D I N G FINAL PLAN NOT FOR CONSTRUCTION 04/16/20 CD101 5 CIVIL DETAILS NA NOR T H CAROLINA JAME B A NC H S M PRO FESSION ENGIN E E R SEAL AL S R ITH 034354 REVISION NO. PROJ. NO.25500.DLD OF: SHEET: DATE: SCALE: DRAWN BY: 34 1 1 M E R C H A N T C O U R T , W I L M I N G T O N , N C 2 8 4 0 5 TH E S E D R A W I N G S A N D S P E C I F I C A T I O N S A R E T H E P R O P E R T Y A N D C O P Y R I G H T O F D O G W O O D L D , P L L C A N D S H A L L N O T B E U S E D O N A N Y O T H E R W O R K E X C E P T B Y A G R E E M E N T W I T H D O G W O O D L D , P L L C . PR O V E R B S 1 6 : 3 C O M M I T Y O U R W O R K S T O T H E L O R D A N D Y O U R P L A N S W I L L B E E S T A B L I S H E D . JBS TH E C A M P G R O U P , L L C 31 1 J U D G E S R D , S U I T E 1 2 F WI L M I N G T O N , N C 2 8 4 0 5 P-2785 12.03.25 5 34 1 1 M E R C H A N T C O U R T CO M M E R C I A L B U I L D I N G FINAL PLAN NOT FOR CONSTRUCTION 04/16/20 EXISTING GROUND COMPACTED BACKFILL TO 98% STD.PROCTOR IF UNDER PAVEMENT COMPACTED BACKFILL PERSPECS AND GEOTECH REPORT 6" M I N . MI N . 1 2 " 6" PI P E D I A . VA R I E S PIPE WIDTH + 24" INITIAL BACKFILL MATERIALCLASS I, II, OR III.SEE SPECS. BEDDING CLASS I, II, OR III MATERIAL FOR MIN. 4" FOR<24"HDPE ANDMIN. 6" FOR >30"HDPESEE SPECS. NOT TO SCALE STORM DRAIN HDPE/HP PIPE TRENCH NOT TO SCALE STORM DRAIN 2X3 INLET GRATE CONTRACTOR MAY SUBMITALTERNATE FOR ENGINEERAPPROVAL. STORM SEWERGRATE REINFORCED CORNERS MANAGEABLE2 FOOT CONTAINMENTAREA LIFTSTRAPS OPTIONALOVERFLOW PORTS DUMPINGSTRAPS STORMINLET DANDY SACK TM NOTE: THE DANDY SACKÔ WILL BE MANUFACTURED IN THE U.S.A. FROM A WOVEN MONOFILAMENT FABRIC DANDY SACKÔ SPECIFICATIONS *Note: All Dandy SacksÔ can be ordered with our optional oil absorbent pillows DANDY SACK INLET PROTECTION NOT TO SCALE 3" SAUCER AROUND TREE REINFORCED RUBBER HOSE CLEAN BACKFILL UNDISTURBED SOIL GUYING STAKE TOP OF ROOTBALL 1" 12"min. SHOWN (TYP.) ORANGE FLAGGING ON GUY WIRE AS TREE WELL ROOT BALL 36" LENGTH2"x2" CEDAR STAKE #12 GAUGE PLAN VIEW WIRE 2" MOUND ABOVE FINISHED GRADE PERMEABLE WEED FABRIC (TYP.) 3" (DEPTH) PINE STRAW 2" MOUND UNDISTURBED SOIL TOP OF ROOT BALL 1" ABOVE FINISHED GRADE CLEAN BACKFILL VARIES 6" VA R I E S 3" SAUCER AROUND SHRUB PERMEABLE WEED FABRIC (TYP.) 3" (DEPTH) PINE STRAW TREE PLANTING DETAIL NOT TO SCALE SHRUB PLANTING DETAIL NOT TO SCALE