Loading...
HomeMy WebLinkAboutSite PlanPROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS T-1 SCOPE OF WORK PROPOSED WORK WILL CONSIST OF PREPARATION AND INSTALLATION OF CELLULAR COMMUNICATION COMPOUND. CONSISTING OF GRADING SITE WORK AND POURING OF CONCRETE FOUNDATIONS FOR CELLULAR EQUIPMENT & TOWER WHERE ALL WORK SHALL BE CONTAINED WITHIN SUBJECT PROPERTY LINES. CODES ALL CONSTRUCTION SPECIFIED ON DOCUMENTS SUBMITTED FOR BUILDING PERMIT SHALL COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING & ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES : ·2018 INTERNATIONAL BUILDING CODE W/ NC AMENDMENTS ·2018 INTERNATIONAL FIRE CODE W/ NC AMENDMENTS ·2018 INTERNATIONAL PLUMBING CODE W/ NC AMENDMENTS ·2018 INTERNATIONAL MECHANICAL CODE W/ NC AMENDMENTS ·2009 INTERNATIONAL ENERGY CONSERVATION CODE ·2017 NATIONAL ELECTRICAL CODE - NFPA 70 ·TIA-222-G ·TIA-1019-A SITE DESIGN SUMMARY: ··WIND LOAD DESIGN:90/120 mph ··EXPOSURE CATEGORY:II ··OCCUPANCY:U ··CONSTRUCTION TYPE:II-A ·FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAP ACCESS IS NOT REQUIRED. ·FACILITY HAS NO SANITARY OR POTABLE WATER ·THERE IS "NO EMERGENCY RESPONSE EQUIPMENT ON THE TOWER AND EXISTING &/OR PROPOSED EQUIPMENT WILL NOT INTERFERE WITH COUNTY EMERGENCY COMMUNICATIONS AND THAT, IF SUCH, INTERFERENCE IS FOUND TO EXIST, THEN APPLICANT WILL TAKE WHATEVER STEPS NECESSARY TO CORRECT INTERFERENCE." FEMA PANEL: THIS SITE IS IN A SPECIAL FLOOD HAZARD AND LABELED ZONE "X SHADED" W/ 0.2% CHANCE OF FLOOD HAZARD, AS SHOWN PER FIRM PANEL: 3720313200K. DATED: 08/28/2018 SITE NAME:THE CAPE BLVD SITE NUMBER:CTG-NC 0010081 DESCRIPTION:NEW SITE DEVELOPMENT 130' CANISTER TOWER PROPERTY OWNER:SOUTHEASTERN ENTERPRISES, INC 1202 LAKE PARK BLV N CAROLINA BEACH, NC 28428 APPLICATION:EVEREST INFRASTRUCTURE PARTNERS TWO ALLEGHENY CENTER, NOVA TOWER 2 SUITE 1002 PITTSBURGH, PA 15212 TED UMINSKI, RL (E)ted.uminski@everestinfrastructure.com (P)412-482-3427 ENGINEERING:P. MARSHALL & ASSOCIATES 3545 WHITEHALL PARK DRIVE SUITE 450 CHARLOTTE, NORTH CAROLINA 28273 TREVOR MCALLISTER (E)tmcallister@pmass.com (P)478-542-3291 NEAREST SITE ADDRESS:613 VALLEY BROOK RD, WILMINGTON, NC 28412 SITE LATITUDE(NAD83):34° 04' 22.77" (34.072992° ) SITE LONGITUDE(NAD83):-77° 54' 06.46" (-77.901794° ) GND ELEVATION (NAVD88):7.4' AMSL TOWER HGHT (AGL.):130.0' JURISDICTION:NEW HANOVER COUNTY PARCEL ID:R08500-002-070-000 ZONING:R-15 ACREAGE (BUA):259,182 SQFT. (5.95 ACRES) LIMITS OF CONSTRUCTION:4,158 SQFT. (0.095 ACRES) (E) IMPERVIOUS SURFACE: 0 SQFT. (P) IMPERVIOUS SURFACE:3,732 SQFT. UTILITIES: POWER COMPANY:NA FIBER COMPANY:NA CALL BEFORE YOU DIG N. CAROLINA ONE-CALL 811 http://www.nc811.com/ TITLE SHEET PROJECT DIRECTORY LOCATION MAP PROJECT SUMMARY SITE SUMMARY CALL BEFORE YOU DIG SHEET INDEX T-1 TITLE SHEET T-2 GENERAL NOTES C-1A SITE PLAN - AERIAL PHOTO C-1B OVERALL SITE PLAN C-2 ENLARGED SITE PLAN C-3 COMPOUND PLAN C-4 TOWER ELEVATION C-5 CONSTRUCTION DETAILS - ACCESS C-6 CONSTRUCTION DETAILS - FENCE C-7 CONSTRUCTION DETAILS - COMPOUND C-8 SIGN DETAILS C-9 GRADING NOTES & DETAILS C-10 GRADING NOTES & DETAILS C-11 GRADING &EROSION CONTROL PLAN C-12 LANDSCAPING PLAN E-1 ELECTRICAL NOTES E-2 ELECTRICAL ONE-LINE E-3 GROUNDING PLAN E-4 ELECTRICAL DETAILS SUPPLEMENTAL SHEET -SURVEY T-1A APPENDIX B SHEETS T-1B APPENDIX B SHEETS PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS T-1A APPENDIX B SHEETS 2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of Project: _______________________________________________________________________________ Address: ______________________________________________________________ Zip Code _____________ Owner/Authorized Agent: _____________ Phone # ( _____ ) _____ - _______E-Mail _______________ Owned By: Code Enforcement Jurisdiction: CONTACT: ___________________________________________________________________________ DESIGNER FIRM NAME LICENSE #TELEPHONE #E-MAIL Architectural _______________________________ ____________ (___)________ ______________ Civil _______________________________ ____________ (___)________ ______________ Electrical _______________________________ ____________ (___)________ ______________ Fire Alarm _______________________________ ____________ (___)________ ______________ Plumbing _______________________________ ____________ (___)________ ______________ Mechanical _______________________________ ____________ (___)________ ______________ Sprinkler-Standpipe ________________ ____________ ____________ (___)________ ______________ Structural _______________________________ ____________ (___)________ ______________ Retaining Walls >5' High ________________________ ____________ (___)________ ______________ Other _______________________________ ____________ (___)________ ______________ (“Other” should include firms and individuals such as truss, precast, pre-engineered, interior designers, etc.) 2018 NC BUILDING CODE: 1st Time Interior Completion Shell/Core - Contact the local inspection jurisdiction for possible additional procedures and requirements Phased Construction - Shell/Core- Contact the local inspection jurisdiction for possible additional procedures and requirements 2018 NC EXISTING BUILDING CODE: EXISTING: Alteration: Historic Property Change of Use CONSTRUCTED: (date) __________CURRENT OCCUPANCY(S) (Ch. 3): __________________ RENOVATED:(date) __________PROPOSED OCCUPANCY(S) (Ch. 3): __________________ RISK CATEGORY (Table 1604.5):Current: I II III IV Proposed: I II III IV BASIC BUILDING DATA Construction Type: I-A II-A III-A IV V-A (check all that apply) I-B II-B III-B V-B Sprinklers: No Partial Yes NFPA 13 NFPA 13R NFPA 13D Standpipes: No Yes Class I II III Wet Dry Fire District: No Yes Flood Hazard Area: No Yes Special Inspections Required: No Yes (Contact the local inspection jurisdiction for additional procedures and requirements.) Gross Building Area Table FLOOR EXISTING (SQ FT)NEW (SQ FT)SUB-TOTAL 3rd Floor 2nd Floor Mezzanine 1st Floor Basement TOTAL ALLOWABLE AREA Primary Occupancy Classification(s): Assembly A-1 A-2 A-3 A-4 A-5 Business Educational Factory F-1 Moderate F-2 Low Hazardous H-1 Detonate H-2 Deflagrate H-3 Combust H-4 Health H-5 HPM Institutional I-1 Condition 1 2 I-2 Condition 1 2 I-3 Condition 1 2 3 4 5 I-4 Mercantile Residential R-1 R-2 R-3 R-4 Storage S-1 Moderate S-2 Low High-piled Parking Garage Open Enclosed Repair Garage Utility and Miscellaneous Accessory Occupancy Classification(s): Incidental Uses (Table 509): Special Uses (Chapter 4 – List Code Sections): Special Provisions: (Chapter 5 – List Code Sections): Mixed Occupancy: No Yes Separation: _____ Hr.Exception: _____________________ Non-Separated Use (508.3) - The required type of construction for the building shall be determined by applying the height and area limitations for each of the applicable occupancies to the entire building. The most restrictive type of construction, so determined, shall apply to the entire building. Separated Use (508.4) - See below for area calculations for each story, the area of the occupancy shall be such that the sum of the ratios of the actual floor area of each use divided by the allowable floor area for each use shall not exceed 1. Actual Area of Occupancy A + Actual Area of Occupancy B Allowable Area of Occupancy A Allowable Area of Occupancy B + _____________________ + …… = ______ < 1 < 1.00 STORY NO. DESCRIPTION AND USE (A) BLDG AREA PER STORY(ACTUAL) (B) TABLE 506.24 AREA (C) AREA FOR FRONTAGE INCREASE1,5 (D) ALLOWABLE AREA PER STORY OR UNLIMITED2,3 1 Frontage area increases from Section 506.3 are computed thus: a. Perimeter which fronts a public way or open space having 20 feet minimum width = _______ (F) b. Total Building Perimeter = ________ (P) c. Ratio (F/P) = ___________ (F/P) d. W = Minimum width of public way = ________ (W) e. Percent of frontage increase If = 100[F/P – 0.25] x W/30 = ________ (%) 2 Unlimited area applicable under conditions of Section 507. 3 Maximum Building Area = total number of stories in the building x D (maximum3 stories) (506.2). 4 The maximum area of open parking garages must comply with Table 406.5.4. 5 Frontage increase is based on the unsprinklered area value in Table 506.2. ALLOWABLE HEIGHT ALLOWABLE SHOWN ON PLANS CODE REFERENCE 1 Building Height in Feet (Table 504.3)2 Building Height in Stories (Table 504.4)3 1 Provide code reference if the “Shown on Plans” quantity is not based on Table 504.3 or 504.4. 2 The maximum height of air traffic control towers must comply with Table 412.3.1. 3 The maximum height of open parking garages must comply with Table 406.5.4. FIRE PROTECTION REQUIREMENTS BUILDING ELEMENT FIRE SEPARATION DISTANCE (FEET) RATING DETAIL # AND SHEET # DESIGN # FOR RATED ASSEMBLY SHEET #FOR RATED PENETRATION SHEET # FOR RATED JOINTS REQ'D PROVIDED (W/_________* REDUCTION) Structural Frame, including columns, girders, trusses Bearing Walls Exterior North East West South Interior Nonbearing Walls and Partitions Exterior walls North East West South Interior walls and partitions Floor Construction Including supporting beams and joists Floor Ceiling Assembly Columns Supporting Floors Roof Construction, including supporting beams and joists Roof Ceiling Assembly Columns Supporting Roof Shaft Enclosures - Exit Shaft E n c l o s u r e s - O t h e r Corridor Separation Occupancy/Fire Barrier Separation Party/Fire Wall Separation Smoke Barrier Separation Smoke Partition Tenant/Dwelling Unit/ Sleeping Unit Separation Incidental Use Separation * Indicate section number permitting reduction PERCENTAGE OF WALL OPENING CALCULATIONS FIRE SEPARATION DISTANCE (FEET)FROM PROPERTYLINES DEGREEOF OPENINGS PROTECTION (TABLE 705.8) ALLOWABLEAREA (%) ACTUALSHOWN ON PLANS (%) LIFE SAFETY SYSTEM REQUIREMENTS Emergency Lighting: No Yes Exit Signs: No Yes Fire Alarm: No Yes Smoke Detection Systems: No Yes Partial _______ Carbon Monoxide Detection: No Yes LIFE SAFETY PLAN REQUIREMENTS Life Safety Plan Sheet #: _____________________ Fire and/or smoke rated wall locations (Chapter 7) Assumed and real property line locations (if not on the site plan) Exterior wall opening area with respect to distance to assumed property lines (705.8) Occupancy Use for each area as it relates to occupant load calculation (Table 1004.1.2) Occupant loads for each area Exit sign locations (1013) Exit access travel distances (1017) Common path of travel distances (Tables 1006.2.1 & 1006.3.2(1)) Dead end lengths (1020.4) Clear exit widths for each exit door Maximum calculated occupant load capacity each exit door can accommodate based on egress width (1005.3) Actual occupant load for each exit door A separate schematic plan indicating where fire rated floor/ceiling and/or roof structure is provided for purposes of occupancy separation Location of doors with panic hardware (1010.1.10) Location of doors with delayed egress locks and the amount of delay (1010.1.9.7) Location of doors with electromagnetic egress locks (1010.1.9.9) Location of doors equipped with hold-open devices Location of emergency escape windows (1030) The square footage of each fire area (202) The square footage of each smoke compartment for Occupancy Classification I-2 (407.5) Note any code exceptions or table notes that may have been utilized regarding the items above ACCESSIBLE DWELLING UNITS (SECTION 1107) UNIT CLASSIFICATION TOTAL UNITS ACCESSIBLE UNITS REQUIRED ACCESSIBLE UNITS PROVIDED TYPE A UNITS REQUIRED TYPE A UNITS PROVIDED TYPE B UNITS REQUIRED TYPE B UNITS PROVIDED TOTAL ACCESSIBLE UNITS PROVIDED ACCESSIBLE PARKING (SECTION 1106) LOT OR PARKING AREA TOTAL #OF PARKING SPACES #OF ACCESSIBLE SPACES PROVIDED TOTAL #ACCESSIBLE PROVIDEDREQUIREDPROVIDED96”SPACES 132”SPACES TOTAL PLUMBING FIXTURE REQUIREMENTS (TABLE 2902.1) USE WATER CLOSETS URINALS LAVATORIES SH O W E R S / T U B S DRINKING FOUNTAINS MALE FEMALE UNISEX MALE FEMALE UNISEX REGULAR ACCESSIBLE SPACE EXIST’G NEW REQ’D SPECIAL APPROVALS Special approval: (Local Jurisdiction, Department of Insurance, OSC, DPI, DHHS, etc., describe below) _____________________________________________________________________________________________ _____________________________________________________________________________________________ ENERGY SUMMARY ENERGY REQUIREMENTS: The following data shall be considered minimum and any special attribute required to meet the energy code shall also be provided. Each Designer shall furnish the required portions of the project information for the plan data sheet. If performance method, state the annual energy cost for the standard reference design vs annual energy cost for the proposed design. Existing building envelope complies with code: No Yes (The remainder of this section is not applicable) Exempt Building: No Yes (Provide code or statutory reference): ______________________ Climate Zone: 3A 4A 5A Method of Compliance: Energy Code Performance Prescriptive ASHRAE 90.1 Performance Prescriptive (If “Other” specify source here) THERMAL ENVELOPE (Prescriptive method only) Roof/ceiling Assembly (each assembly) Description of assembly: ______________________________ U-Value of total assembly: ___________ R-Value of insulation: ___________ Skylights in each assembly: ___________ U-Value of skylight: ___________ total square footage of skylights in each assembly: ___________ Exterior Walls (each assembly) Description of assembly: ______________________________ U-Value of total assembly: ___________ R-Value of insulation: ___________ Openings (windows or doors with glazing) U-Value of assembly:___________ Solar heat gain coefficient:___________ projection factor:___________ Door R-Values:___________ Walls below grade (each assembly) Description of assembly: ______________________________ U-Value of total assembly: ___________ R-Value of insulation: ___________ Floors over unconditioned space (each assembly) Description of assembly: ______________________________ U-Value of total assembly: ___________ R-Value of insulation: ___________ Floors slab on grade Description of assembly: ______________________________ U-Value of total assembly: ___________ R-Value of insulation: ___________ Horizontal/vertical requirement:___________ slab heated:___________ N/A N O T A BUIL D I N G N/A N O T A BUIL D I N G N/A N O T A BUIL D I N G N/A N O T A BUIL D I N G N/A N O T A BUIL D I N G N/A N O T A BUIL D I N G The Cape Blvd. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 TED UMINSKI 412 482 3427 ted.uminski@ everestinfrastructure .comCity/County Private State City____________ County_________ State New Construction Addition Renovation Prescriptive Repair Chapter 14 Level I Level II Level III P. MARSHALL & ASSOCIATES/ CENTERLINE ENGINEERING SERVICES Philip Burtner 39614 610 730-5430 P. MARSHALL & ASSOCIATES/ CENTERLINE ENGINEERING SERVICES Philip Burtner 39614 610 730-5430 pburtner@pmass.com pburtner@pmass.com UTILITY/MISCELLANEOUS PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS T-1B APPENDIX B SHEETS 2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS STRUCTURAL DESIGN (PROVIDE ON THE STRUCTURAL SHEETS IF APPLICABLE) DESIGN LOADS: Importance Factors: Live Loads: Ground Snow Load: Wind Load: Snow (IS) _________ Seismic (IE) _________ Roof Mezzanine Floor _________ psf Ultimate Wind Speed SEISMIC DESIGN CATEGORY: Provide the following Seismic Design Parameters: Occupancy Category (Table 1604.5) A Data Source: Basic structural system Analysis Procedure: LATERAL DESIGN CONTROL: A I Spectral Response Acceleration SS_________ %g Site Classification (ASCE 7)B Field Test Bearing Wall Building Frame Moment Frame Simplified Architectural, Mechanical, Components anchored? Earthquake _________ mph (ASCE-7) Exposure Category _________ B II C C III Presumptive D IV S1_________ %g D E F Historical Data Dual w/Special Moment Frame Dual w/Intermediate R/C or Special Steel Inverted Pendulum Equivalent Lateral Force Yes No Wind SOIL BEARING CAPACITIES: Field Test (provide copy of test report) ___________________ psf Presumptive Bearing capacity __________________________ psf Pile size, type, and capacity ______________________________________ Dynamic _________ psf _________ psf _________ psf 2018 NC Administrative Code and Policies Appendix B for Building 2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS MECHANICAL DESIGN (PROVIDE ON THE MECHANICAL SHEETS IF APPLICABLE) MECHANICAL SUMMARY MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT Thermal Zone winter dry bulb: ___________ summer dry bulb: ___________ Interior design conditions winter dry bulb: ___________ summer dry bulb: ___________ relative humidity: ___________ Building heating load:___________ Building cooling load:___________ Mechanical Spacing Conditioning System Unitary description of unit:___________ heating efficiency:___________ cooling efficiency:___________ size category of unit: ___________ Boiler Size category. If oversized, state reason.:___________ Chiller Size category. If oversized, state reason.:___________ List equipment efficiencies:___________ 2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS ELECTRICAL DESIGN (PROVIDE ON THE ELECTRICAL SHEETS IF APPLICABLE) ELECTRICAL SUMMARY ELECTRICAL SYSTEM AND EQUIPMENT Method of Compliance: Energy Code Performance Prescriptive ASHRAE 90.1 Performance Prescriptive Lighting schedule (each fixture type) lamp type required in fixture number of lamps in fixture ballast type used in the fixture number of ballasts in fixture total wattage per fixture total interior wattage specified vs. allowed (whole building or space by space) total exterior wattage specified vs. allowed Additional Efficiency Package Options (When using the 2018 NCECC; not required for ASHRAE 90.1) C406.2 More Efficient HVAC Equipment Performance C406.3 Reduced Lighting Power Density C406.4 Enhanced Digital Lighting Controls C406.5 On-Site Renewable Energy C406.6 Dedicated Outdoor Air System C406.7 Reduced Energy Use in Service Water Heating N/A N O T A BUIL D I N G N/A N O T A BUIL D I N G 112 C NA NA NA 1 1 20 NA NA N/A N O T A BUIL D I N G PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS T-2 GENERAL NOTES &AND AMSL AVERAGE ABOVE MEAN SEALEVEL BTM. BOTTOM ℄CENTERLINE CONC.CONCRETE CONT.CONTINOUS C.J. CONTROL JOINT DIA.DIAMETER (E)EXISTING EL.ELEVATION E.S.EACH SIDE E.W.EACH WAY FFI FLANGE FACING INSIDE FFO FLANGE FACING OUTSIDE FT.FEET F.V.FIELD VERIFY GALV.GALVANIZED HORIZ.HORIZONTAL IN.INCH LFP LEG FACING OUTSIDE LLVD LONG LEG VERTICAL DOWN LLVU LONG LEG VERTICAL UP MAX.MAXIMUM MFR. MANUFACTURER MIN.MINIMUM MPH MILES PER HOUR O.C.ON CENTER (P)PROPOSED REINF. REINFORCE REQ'D REQUIRED SIM.SIMILAR STD. STANDARD STL. STEEL TYP. TYPICAL UNO UNLESS NOTED OTHERWISE VERT.VERTICAL VLD VERTICAL LEG DOWN VLU VERTICAL LEG UP W/ WITH GENERAL NOTES ABBREVIATION KEY 1.THE GENERAL CONTRACTOR MUST VERIFY ALL EXISTING & PROPOSED DIMENSIONS, CONDITIONS, AND ELEVATIONS BEFORE STARTING WORK. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER AND SHALL BE RESOLVED BEFORE PROCEEDING WITH THE WORK. ALL WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH ACCEPTED CONSTRUCTION PRACTICES. 2.IT IS THE INTENTION OF THESE DRAWINGS TO SHOW THE COMPLETED INSTALLATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING, SHORING, TIES, FORM WORK, ETC., IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL ORDINANCES, TO SAFELY EXECUTE ALL WORK AND SHALL BE RESPONSIBLE FOR SAME. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES. 3.THE CONTRACTOR SHALL USE ADEQUATE NUMBER OF SKILLED WORKMEN WHO ARE THOROUGHLY TRAINED AND EXPERIENCED IN THE NECESSARY CRAFTS AND WHO ARE 3. COMPLETELY FAMILIAR WITH THE SPECIFIED REQUIREMENTS AND METHODS NEEDED FOR PROPER PERFORMANCE OF THE WORK. 4.CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY. THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND PRIME CONTRACTOR FURTHER AGREES TO INDEMNIFY AND HOLD DESIGN ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH PERFORMANCE OF WORK ON THIS PROJECT. 5.SITE GROUNDING SHALL COMPLY WITH ENERGY GROUNDING STANDARDS, LATEST VERSION. WHEN NATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT, THEY 5. SHALL GOVERN. GROUNDING SHALL BE COMPLETED BEFORE ERECTION OF A NEW TOWER. 6.ALL WORK SHALL COMPLY WITH OSHA AND STATE SAFETY REQUIREMENTS. PROCEDURES FOR THE PROTECTION OF EXCAVATIONS, EXISTING CONSTRUCTION, AND UTILITIES 6. SHALL BE ESTABLISHED PRIOR TO FOUNDATION INSTALLATION. IF TEMPORARY LIGHTING AND MARKING IS REQUIRED BY THE FEDERAL AVIATION ADMINISTRATION (FAA), IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN THE NECESSARY LIGHTS AND NOTIFY THE PROPER AUTHORITIES IN THE EVENT OF A PROBLEM. 7.ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL CODES OR ORDINANCES. THE MOST STRINGENT CODE WILL APPLY IN THE CASE OF DISCREPANCIES OR DIFFERENCES IN THE CODE REQUIREMENTS. 8.THE CONTRACTOR SHALL RESTORE ALL PROPERTY TO IT'S PRE-CONSTRUCTION CONDITIONS TO THE OWNER'S SATISFACTION. ANY DAMAGE TO ADJACENT PROPERTIES WILL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. THE CONTRACTOR IS TO PROTECT ALL EXISTING PROPERTY LINE MONUMENTATION, STRUCTURES, UTILITIES. ANY DAMAGE SHALL BE REPAIRED OR REPLACED AT THE CONTRACTOR'S EXPENSE UNDER THE SUPERVISION OF A REGISTERED SURVEYOR OR ENGINEER. 9.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AMPLE NOTICE TO THE BUILDING INSPECTION DEPARTMENT TO SCHEDULE THE REQUIRED INSPECTIONS. A MINIMUM OF 24 9. HOURS OF NOTICE SHOULD BE GIVEN THE BUILDING INSPECTION DEPARTMENTS HAVE REQUESTED THAT GROUPS OF TWO OR THREE SITES BE SCHEDULED AT ONE TIME IF POSSIBLE. 10.THE COMPLETE BID PACKAGE INCLUDES THESE CONSTRUCTION DRAWINGS ALONG WITH THE SPECIFICATIONS AND TOWER DRAWINGS/ANALYSIS. CONTRACTOR IS 10. RESPONSIBLE FOR REVIEW OF THE TOTAL BID PACKAGE PRIOR TO BID SUBMITTAL. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO EXAMINE ALL DRAWGINS & SPECIFICATIONS AND TO COORDINATE HIS WORK WITH THE WORK OF ALL OTHER TO ENSURE THAT WORK PROGRESSION IS INTERRUPTED AND DOES NOT INTERRUPT THE PROPERTY OWNER'S OPERATIONS AT ANY TIME. 11. THE CONTRACTOR SHALL VERIFY LOCATIONS OF ALL EXISTING UTILITIES WITHIN THE CONSTRUCTION LIMITS PRIOR TO CONSTRUCTION. ALL CONNECTIONS TO EXISTING SYSTEMS SHALL BE COORDINATED WITH THE OWNER OR OWNER'S REPRESENTATIVE AND THE UTILITY COMPANY PRIOR TO EACH CONNECTION. 12.THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING POSITIVE DRAINAGE ON THE SITE AT ALL TIMES. SILT AND EROSION CONTROL SHALL BE MAINTAINED ON THE 12. DOWNSTREAM SIDE OF THE SITE AT ALL TIMES. ANY DAMAGE TO ADJACENT PROPERTIES WILL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. 13.CLEARING OF TREES AND VEGETATION ON THE SITE SHOULD BE KEPT TO A MINIMUM. ONLY THE TREES NECESSARY FOR CONSTRUCTION OF THE FACILITIES SHALL BE REMOVED. ANY DAMAGE TO PROPERTY OUTSIDE THE LEASED PROPERTY SHALL BE REPAIRED BY THE CONTRACTOR. 14.ALL SUITABLE BORROW MATERIAL FOR BACKFILL OF THE SITE SHALL BE INCLUDED IN THE BID. EXCESS TOPSOIL AND UNSUITABLE MATERIAL SHALL BE DISPOSED OF OFF SITE AT LOCATIONS APPROVED BY GOVERNING AGENCIES PRIOR TO DISPOSAL. 15.SEEDING AND MULCHING OF THE SITE WILL BE ACCOMPLISHED AS SOON AS POSSIBLE AFTER COMPLETION OF THE SITE DEVELOPMENT. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND MAINTAINING AN ADEQUATE COVER OF VEGETATION OVER THE SITE FOR A ONE YEAR PERIOD. 16.RECORD DRAWINGS: MAINTAIN A RECORD OF ALL CHANGES, SUBSTITUTIONS, ETC., BETWEEN THE WORK AS SPECIFIED AND INSTALLED. RECORD CHANGES ON A CLEAN SET OF CONTRACT DRAWINGS WHICH SHALL BE TURNED OVER TO THE CONSTRUCTION MANAGER UPON COMPLETION OF THE PROJECT. 17. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED LICENSES, FEES, INSPECTIONS, ETC. BUILDING PERMITS WILL BE OBTAINED BY CONTRACTOR & PAID FOR BY THE COUNTY. 18.CONTRACTOR SHALL KEEP THE PROJECT SITE FREE FROM ACCUMULATION OF WASTE MATERIALS & RUBBISH AT ALL TIMES DURING CONSTRUCTION PERIOD & SHALL REMOVE. ALL WASTE MATERIALS & RUBBISH FROM PROJECT SITE AT THE COMPLETION OF WORK, EXCEPT THOSE SPECIFICALLY REQUIRED BY THE CONTRACT DOCUMENTS TO BE LEFT FOR THE OWNER'S MAINTENANCE. CONSTRUCTION WASTE MAY NEITHER BE BURNED NOR BURIED AND MUST BE TAKEN TO AN APPROVED LANDFILL AT CONTRACTOR EXPENSE. 19.SECURITY TO THE SITE SHALL BE MAINTAINED AT ALL TIMES. 20.CONTRACTOR IS RESPONSIBLE FOR THE CONDITION OF THE ALL CABINETS AND /OR SHELTER DURING AND AFTER CONSTRUCTION. CABINETS AND /OR SHELTERS SHALL NOT BE USED FOR STORAGE OF TOOLS, CONSTRUCTION MATERIAL OR EQUIPMENT. CONTRACTOR SHALL ENSURE THE CABINETS AND /OR SHELTERS IS CLEANED AT THE CONCLUSION OF CONSTRUCTION. SHELTER FLOORS SHALL BE CLEANED, WAXED AND BUFFED TO SHINE. GENERAL NOTES PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS C-1A SITE PLAN - AERIAL PHOTO 1.SITE PLAN SHOWN WAS TAKEN FROM SURVEY INFORMATION PROVIDED BY POINT TO POINT LAND SURVEYORS, INC. CONTRACTOR TO VERIFY ALL EXISTING INFORMATION IS INDICATED ON SITE PLAN. CONTRACTOR IS TO ESTABLISH THE EXISTENCE AND LOCATION OF ALL EXISTING UNDERGROUND AND OVERHEAD UTILITIES. IMMEDIATELY NOTIFY THE CONSTRUCTION MANAGER OF ANY DISCREPANCIES. 2.PARCEL DATA SHOWN WAS TAKEN FROM INFORMATION PROVIDED BY POINT TO POINT LAND SURVEYORS, INC & NEW HANOVER COUNTY GIS, PROPERTY INFORMATION RESEARCH WEB SITE. 3.EXISTING WETLANDS ON SITE DESIGNATED AS FRESHWATER FORESTED/SHRUB WETLAND (PFO4Bd) 4.ALL CONSTRUCTION ACTIVITY MUST BE IN ACCORDANCE WITH THE ACCEPTED POLICIES BY NORTH CAROLINA STATE CODE. 5.PROPOSED ROUTES ARE SHOWN AS SCHEMATIC. 6.HAND DIG ALL EXISTING UTILITIES DEEPER THAN 12" TO LOCATE GENERAL NOTES GRAPHIC SCALE NORTH ARROW W N EMP A& S 00' SCALE: 1" = 100' SUBJECT PARENT PARCEL SOUTHEASTERN ENTERPRISES INC. PARCEL ID: R08500-002-070-000 ZONE: R-15 ACRE: 5.95 VALLEY B R O O K R O A D ( 6 0 ' P R I V A T E R / W ) TELFAIR SUMMIT HOA INC. PARCEL ID: R08500-002-071-000 ZONE: R-15 ACRE: 5.54 SOUTHEASTERN ENTERPRISES INC. PARCEL ID: R08500-002-114-000 ZONE: R-15 ACRE: 2.97 100'100' CRESS LOUIS H ETAL PARCEL ID: R08510-007-021-000 ZONE: R-15 ACRE: 0.36 COOK TED E KATHLEEN M PARCEL ID: R08510-007-020-000 ZONE: R-15 ACRE: 0.34 BREWSTER JACK R RITA ANN REV TRUST PARCEL ID: R08510-007-019-000 ZONE: R-15 ACRE: 0.32 GRICZEWICZ CAITLIN STEPHEN A RIES PARCEL ID: R08510-007-018-000 ZONE: R-15 ACRE: 0.35 SOUTHERN DESTINY LLC PARCEL ID: R08500-002-029-002 ZONE: R-15 ACRE: 32.76 PROPOSED 25' LANDSCAPE BUFFER/ TREE PRESERVATION AREA (SUSTAIN/PROTECT EXISTING TREES) PROPOSED 42'x40' COMPOUND PROPOSED CANISTER TOWER PROPOSED 30' UTILITY/ACCESS/FIBER EASEMENT SUBJECT PARENT PARCEL ADJACENT PARCEL LINEEXISTING TREELINE (TYP.) LIGHT POLE & TELCO (TYP.) PROPOSED 100'x100' LEASE AREA IMPACT TABLE PROPOSED 12' ACCESS DRIVE EXISTING TRACT SIZE:259,182 SQ.FT. (5.95 ACRES) LIMIT OF CONSTRUCTION:4,158 SQ. FT (0.095 ACRES) EXISTING PERVIOUS/ IMPERVIOUS AREA TOTAL EXISTING PERVIOUS AREA:259,182 SQFT. (5.95 ACRES) TOTAL EXISTING IMPERVIOUS AREA:0000 SQFT. (.000 ACRES) PROPOSED IMPERVIOUS AREA 3,732 SQFT.(0.085 ACRES) PROPOSED IMPERVIOUS AREA INCREASE: COMPOUND 1,676 SQFT. (0.04 ACRES) GRAVEL DRIVE 2,056 SQFT.(0.05 ACRES) TOTAL PROPOSED PERVIOUS AREA:255,450 SQFT. (5.86 ACRES) PROPOSED IMPERVIOUS AREA:3,732 SQFT. (0.085 ACRES) IMPERVIOUS SURFACE AREA (ISR) & PERVIOUS SURFACE AREA (PSR) PROPOSED ISR: 3,732/ 259,182 = 1.439% PROPOSED PSR:255,450/ 259,182 =98.560% FILL VOLUMES BFE = 9'EX. GRADE = 7'MITIGATION= BFE - GRADE = 2' PROPOSED FILL VOLUME (DIRT): 2386.83 CUBIC FT. PROPOSED FILL VOLUME (GRAVEL): 2763.61 CUBIC FT. PROPOSED FILL VOLUME (CONCRETE): 177.56 CUBIC FT. 13 0 ' - 0 " 659'-7" 13 0 ' - 0 " 40 7 ' - 1 1 " PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS C-1B OVERALL SITE PLAN 1.SITE PLAN SHOWN WAS TAKEN FROM SURVEY INFORMATION PROVIDED BY POINT TO POINT LAND SURVEYORS, INC. CONTRACTOR TO VERIFY ALL EXISTING INFORMATION IS INDICATED ON SITE PLAN. CONTRACTOR IS TO ESTABLISH THE EXISTENCE AND LOCATION OF ALL EXISTING UNDERGROUND AND OVERHEAD UTILITIES. IMMEDIATELY NOTIFY THE CONSTRUCTION MANAGER OF ANY DISCREPANCIES. 2.PARCEL DATA SHOWN WAS TAKEN FROM INFORMATION PROVIDED BY POINT TO POINT LAND SURVEYORS, INC & NEW HANOVER COUNTY GIS, PROPERTY INFORMATION RESEARCH WEB SITE. 3.EXISTING WETLANDS ON SITE DESIGNATED AS FRESHWATER FORESTED/SHRUB WETLAND (PFO4Bd) 4.ALL CONSTRUCTION ACTIVITY MUST BE IN ACCORDANCE WITH THE ACCEPTED POLICIES BY NORTH CAROLINA STATE CODE. 5.PROPOSED ROUTES ARE SHOWN AS SCHEMATIC. 6.HAND DIG ALL EXISTING UTILITIES DEEPER THAN 12" TO LOCATE GENERAL NOTES GRAPHIC SCALE NORTH ARROW W N EMP A& S 00' SCALE: 1" = 100' ZONE "X" (AREA OF MINIMAL FLOOD HAZARD) SUBJECT PARENT PARCEL SOUTHEASTERN ENTERPRISES INC. PARCEL ID: R08500-002-070-000 ZONE: R-15 ACRE: 5.95 VALLEY B R O O K R O A D ( 6 0 ' P R I V A T E R / W ) TELFAIR SUMMIT HOA INC. PARCEL ID: R08500-002-071-000 ZONE: R-15 ACRE: 5.54 SOUTHEASTERN ENTERPRISES INC. PARCEL ID: R08500-002-114-000 ZONE: R-15 ACRE: 2.97 100'100' CRESS LOUIS H ETAL PARCEL ID: R08510-007-021-000 ZONE: R-15 ACRE: 0.36 COOK TED E KATHLEEN M PARCEL ID: R08510-007-020-000 ZONE: R-15 ACRE: 0.34 BREWSTER JACK R RITA ANN REV TRUST PARCEL ID: R08510-007-019-000 ZONE: R-15 ACRE: 0.32 GRICZEWICZ CAITLIN STEPHEN A RIES PARCEL ID: R08510-007-018-000 ZONE: R-15 ACRE: 0.35 SOUTHERN DESTINY LLC PARCEL ID: R08500-002-029-002 ZONE: R-15 ACRE: 32.76 PROPOSED 25' LANDSCAPE BUFFER/ TREE PRESERVATION AREA (SUSTAIN/PROTECT EXISTING TREES) PROPOSED 42'x40' COMPOUND PROPOSED CANISTER TOWERPROPOSED 30' UTILITY/ACCESS/FIBER EASEMENT SUBJECT PARENT PARCEL ADJACENT PARCEL LINE130' TOWER FALL ZONE EXISTING WETLANDS (PF04Bd) EXISTING TREELINE (TYP.) FLOOD ZONE KEY 15" CMP (END BURRIED) LIGHT POLE & TELCO (TYP.) ZONE "AE" (BASE FLOOD ELEVATION 9') SHADED ZONE "X" (0.2% ANNUAL CHANCE FLOOD HAZARD) FLOOD PLAIN LINE (TYP.) PROPOSED 100'x100' LEASE AREA PROPOSED 12' ACCESS DRIVE IMPACT TABLE EXISTING TRACT SIZE:259,182 SQ.FT. (5.95 ACRES) LIMIT OF CONSTRUCTION:4,158 SQ. FT (0.095 ACRES) EXISTING PERVIOUS/ IMPERVIOUS AREA TOTAL EXISTING PERVIOUS AREA:259,182 SQFT. (5.95 ACRES) TOTAL EXISTING IMPERVIOUS AREA:0000 SQFT. (.000 ACRES) PROPOSED IMPERVIOUS AREA 3,732 SQFT.(0.085 ACRES) PROPOSED IMPERVIOUS AREA INCREASE: COMPOUND 1,676 SQFT. (0.04 ACRES) GRAVEL DRIVE 2,056 SQFT.(0.05 ACRES) TOTAL PROPOSED PERVIOUS AREA:255,450 SQFT. (5.86 ACRES) PROPOSED IMPERVIOUS AREA:3,732 SQFT. (0.085 ACRES) IMPERVIOUS SURFACE AREA (ISR) & PERVIOUS SURFACE AREA (PSR) PROPOSED ISR: 3,732/ 259,182 = 1.439% PROPOSED PSR:255,450/ 259,182 =98.560% FILL VOLUMES BFE = 9'EX. GRADE = 7'MITIGATION= BFE - GRADE = 2' PROPOSED FILL VOLUME (DIRT): 2386.83 CUBIC FT. PROPOSED FILL VOLUME (GRAVEL): 2763.61 CUBIC FT. PROPOSED FILL VOLUME (CONCRETE): 177.56 CUBIC FT. X X PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS C-2 ENLARGED SITE PLAN PROPOSED 8' CHAIN-LINKED BARBED WIRE FENCE AND 1' DIAMETER CONCRETE FOUNDATION AS SHOWN ON SHEET C-6 PROPOSED CANISTER TOWER WITH 10' DIAMETER CONCRETE FOUNDATION PROPOSED 12' GRAVEL DRIVE PROPOSED 30' ACCESS/ UTILITY/FIBER EASEMENT PROPOSED 16' SWING GATE VALLEY B R O O K R O A D ( 6 0 ' P R I V A T E R / W ) EXISTING15" CMP (END BURRIED) EXISTING LIGHT POLE & TELCO (TYP.) EXISTING PLANTED TREES (TYP.) PROPOSED 25' LANDSCAPE BUFFER/ TREE PRESERVATION AREA (SUSTAIN/PROTECT EXISTING TREES) SUBJECT PARENT PARCEL PROPOSED 6" OF #57 STONE ON GEOSYNTHETIC FABRIC PROPOSED100'X100' LEASE AREA LIMITS OF CONSTRUCTION, 14' IN WIDTH (TYP.) IMPACT TABLE 12X20 12X20 10X15 KEY GRAVEL DRIVE/ COMPOUND CONCRETE FOUNDATION NORTH ARROW W N EMP A& S EXISTING TRACT SIZE:259,182 SQ.FT. (5.95 ACRES) LIMIT OF CONSTRUCTION:4,158 SQ. FT (0.095 ACRES) EXISTING PERVIOUS/ IMPERVIOUS AREA TOTAL EXISTING PERVIOUS AREA:259,182 SQFT. (5.95 ACRES) TOTAL EXISTING IMPERVIOUS AREA:0000 SQFT. (.000 ACRES) PROPOSED IMPERVIOUS AREA 3,732 SQFT.(0.085 ACRES) PROPOSED IMPERVIOUS AREA INCREASE: COMPOUND 1,676 SQFT. (0.04 ACRES) GRAVEL DRIVE 2,056 SQFT.(0.05 ACRES) TOTAL PROPOSED PERVIOUS AREA:255,450 SQFT. (5.86 ACRES) PROPOSED IMPERVIOUS AREA:3,732 SQFT. (0.085 ACRES) IMPERVIOUS SURFACE AREA (ISR) & PERVIOUS SURFACE AREA (PSR) PROPOSED ISR: 3,732/ 259,182 = 1.439% PROPOSED PSR:255,450/ 259,182 =98.560% FILL VOLUMES BFE = 9'EX. GRADE = 7'MITIGATION= BFE - GRADE = 2' PROPOSED FILL VOLUME (DIRT): 2386.83 CUBIC FT. PROPOSED FILL VOLUME (GRAVEL): 2763.61 CUBIC FT. PROPOSED FILL VOLUME (CONCRETE): 177.56 CUBIC FT. ELEC ELEC ELEC ELECELEC ELECELECELECELEC ELE C ELE C ELE C ELE C EL E C EL E C EL E C EL E C EL E C EL E C EL E C EL E C EL E C EL E C EL E C EL E C 42 ' - 0 " 33'-0" 1'-1" 8' - 0 " 1' - 0 " 12 ' - 0 " 7'-1" 7' - 1 " 35 ' - 0 " 15 ' - 0 " 43 ' - 0 " 10 0 ' - 0 " 17'-0" 43'-0" 100'-0" 40'-0" 30 ' - 0 " 17'-0" R1 0 ' - 0 " NORTH ARROW W N EM P A & S GENERAL NOTES GRAPHIC SCALE 00' SCALE: 1" = 20' 20'20' COMPOUND PLAN 1.ALL MATERIAL AND EQUIPMENT FURNISHED SHALL BE NEW AND OF GOOD QUALITY. FREE FROM FAULTS AND DEFECTS AND IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. ANY SUBSTITUTIONS MUST BE PROPERLY APPROVED AND AUTHORIZED IN WRITING BY THE OWNER AND ENGINEER PRIOR TO INSTALLATION. CONTRACTOR SHALL FURNISH SATISFACTORY EVIDENCE AS TO THE KIND OF QUALITY OF MATERIAL AND EQUIPMENT BEING SUBSTITUTED. 2.ACCESS TO PROPOSED WORK SITE MAY BE RESTRICTED. THE CONTRACTOR SHALL COORDINATE INTENDED CONSTRUCTION ACTIVITY, INCLUDING WORK SCHEDULE AND MATERIALS ACCESS WITH THE LEASING AGENT FOR APPROVAL. 3.CONTRACTOR SHALL HAVE PRESENT ON SITE CURRENT CARRIER SUPPLIED INFORMATION PRIOR TO COMMENCE OF WORK; IE. RFDS, DESIGN DOCUMENTS SPECIFIC TO SITE AND CONFIGURATION. NOTIFY CONSTRUCTION MANAGER OF ANY DISCREPANCY PRIOR TO ARRIVAL AT SITE. 4.ALL HARDWARE ASSEMBLY MANUFACTURER'S INSTRUCTION SHALL BE FOLLOWED EXACTLY AND SHALL SUPERSEDE ANY CONFLICTING NOTES ENCLOSED HEREIN. 5.ALL DAMAGE TO EXISTING UNDERGROUND, OVERHEAD OBSTACLES AND/OR EXISTING EQUIPMENT, PAD OR SHELTERS SHALL BE REPLACED BACK TO FULL ORIGINAL OR BETTER CONDITION & SHALL MATCH EXISTING CONDITIONS BY REPAIRS AT GENERAL CONTRACTOR EXPENSE. 6.THE EXISTING TREES AND VEGETATION ARE SUFFICIENT, UNO, TO PROVIDE THE REQUIRED SCREENING PER LOCAL ORDINANCE. IF THE VEGETATION IS REMOVED OR DAMAGED, NEW LANDSCAPING/ SCREENING WILL BE INSTALLED TO MEET LOCAL ORDINANCE REQUIREMENTS. HATCH LEGEND GRAVEL DRIVE/ COMPOUND PROPOSED TREE LINE (TYP.) PROPOSED 12' GRAVEL DRIVE PROPOSED 6" OF #57 STONE ON GEOSYNTHETIC FABRIC PROPOSED 8' CHAIN-LINKED BARBED WIRE FENCE 12' CHAIN-LINKED GATE PROPOSED 100'X100 'LEASE AREA PROPOSED 25' LANDSCAPE BUFFER/ TREE PRESERVATION AREA (SUSTAIN/PROTECT EXISTING TREES) PROPOSED 30' ACCESS/ UTILITY/FIBER EASEMENT. CLEAR EXISTING TREE LINE FOR ACCESS. PROPOSED 6'-0" CARRIER MULTI-GANG POWER METER & TELCO DEMARC. CONNECT SUPPLY CONDUITS 5'-0" OUTSIDE OF FENCE LINE. COORDINATE WITH LOCAL UTILITY COMPANY REGARDING FINAL SERVICE CONNECTION. PROPOSED TOWER PROPOSED UNDERGROUND 3" SCH. 40 PVC CONDUIT FROM PROPOSED 4-GANG METER ON H-FRAME. CAP OPEN CONDUIT WATER TIGHT PRIOR TO INSTALLATION. COORDINATE WITH LOCAL UTILITY COMPANY REGARDING FINAL SERVICE CONNECTION. PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS C-3 PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS C-4 GENERAL NOTES 1.REFER TO TOWER STRUCTURAL ANALYSIS FOR PROPOSED ANTENNA CABLE LOADING DETAILS 2.TOWER ELEVATION SHOWN IS NOT DRAWN TO SCALE AND IS ONLY INTENDED FOR REFERENCE PURPOSES. REFER TO ORIGINAL TOWER DESIGN FOR ADDITIONAL INFORMATION. 3.ALL TOWER DIMENSIONS SHALL BE VERIFIED WITH THE PLANS PRIOR TO COMMENCING CONSTRCTION. NOTIFY TH EENGINEER IMMEDIATELY IF ANY DISCREPANCIES ARE DISCOVERED. 4.ALL HARDWARE ASSEMBLE MANUFACTURER'S INSTRUCTIONS SHALL BE FOLLOWED EXACTLY AND SHALL SUPERSEDE ANY CONFLICTING NOTES ENCLOSED HEREIN. 5.ALL MATERIALS AND EQUIPMENT FURNISHED SHALL BE NEW AND OF GOOD QUALITY, FREE FROM FAULTS AND DEFECTS AND IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. ANY AND ALL SUBSTITUTIONS MUST BE PROPERLY APPROVED AND AUTHORIZED IN WRITING BU THE OWNER AND ENGINEER PRIOR TO INSTALLATION. CONTRACTOR SHALL FURNISH SATISFACTORY EVIDENC AS TO THE KIND OF QUALITY OF THE MATERIALS AND EQUIPMENT BEING SUBSTITUTED. FINISH NOTES: TOWER-GALVANIZED TOWER MOUNTS-GALVANIZED ANTENNA-NEUTRAL (MANUFACTURER FINISH) FOUNDATIONS-UNPAINTED CONCRETE ICE BRIDGE- GALVANIZED CABLES-BLACK BASE CABINETS/EQUIPMENT-NEUTRAL (MANUFACTURER FINISH) TOWER ELEVATION PR O P O S E D T O W E R H E I G H T 1 3 0 ' - 0 " A . G . L . CARRIER CENTERLINE 124'-0" PROPOSED CANISTER TOWER FUTURE ANTENNAS BY OTHERS (TYP ) CARRIER CENTERLINE 112'-0" CARRIER CENTERLINE 100'-0" T/GRADE 0'-0" 15'x12' FRP ANTENNA CONCEALMENT SHADE (TYP. OF 3) T/O TOWER STEEL 130'-0" PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS C-5 EXISTING GRADE PROPOSED SUBGRADE COMPACTED TO 95% STANDARD PROCTOR PROPOSED 20 MIL. LIGHT WEIGHT WOVEN SLIT FILM POLYPROPYLENE GEOSYNETHIC FABRIC (500X MIRAFI GEOTEXTILE OR EQUAL) PROPOSED 2" FINISH LAYER OF ROLLED #57 STONE 2% SLOPE 12'-0" 30'-0" UTILITY/ ACCESS EASEMENT 2% SLOPE PROPOSED GRAVEL ACCESS CROWN ·AGGREGATE IS BASED ON STANDARD AASHTO ·2" CROWN IN CENTER OF ACCESS, UNLESS IN CURVES, THEN ACCESS SHOULD BE SLOPED TO INSIDE OF TURN OR CURVE. ·ALL MATERIALS SHALL MEET DOT STANDARD SPECIFICATION FOR ROAD CONSTRUCTION. ·GRAVEL BASE & TOP COURSE DEPTH SHOWN AS MIN. INCREASE DEPTH MAY BE REQUIRED DUE TO POOR SOIL CONDITIONS. ·MAX. GRADE: 123% GREATER THAN MAY REQUIRE PAVED SURFACE. ·PRIVATELY MAINTAINED ROAD ONLY. ·NO POTENTIAL FOR FURTHER DEVELOPMENT. THIS IS NOT A THRU ROAD. SCALE: NTS ACCESS DRIVE NOTES 1'-0" TYP. CONSTRUCTION DETAILS- ACCESS SCALE: NTS ACCESS DRIVE SWING GATE FINISH GRADE (12' GRAVEL ACCESS DRIVE) 3' - 8 " 16'-0" 3" SQUARE TUBE STEEL. PAINTED BLACK (TYP.) 3' 6 " 18" (TYP.) 3' - 0 " 4" ( T Y P . ) SECURE LANE LLC (520)780-9751 SL-SG MANUAL SWING GATE OR SIMILAR. AVAILABLE IN SINGLE SWING OR DUAL SWING @ WWW. BARRIERGATEARM.COM 4000 PSI CONCRETE POST FOOTING, MIN. (TYP.) 4" ROUND STEEL POST PAINTED BLACK (TYP.) HD BEARING HINGES (TYP.OF 2) SLIDE BOLT LOCKING MECHANISM WITH TAB HASPS & PADLOCK. GC TO COORDINATE WITH OWNER FOR FINAL COMBINATION. NOTES EXISTING TREE LINEEXISTING TREE LINE PROPOSED 6" OF FILL DIRT (AS SPECIFIED ON SHEET C-11)BORROWED EXCAVATION COMPACTED TO 95% PROCTOR PROPOSED 2" ELECTRICAL CONDUIT (TYP. 2) FOR POWER SUPPLY TO COMPOUND TO BE PLACED 30" BELOW GRADE 14'-0" LIMIT OF CONSTRUCTION 30 " MI N . PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS C-6 1'-6" 6" 9" 10" 18 " 3' - 6 " 13 " SCALE: NTS ACCESS DRIVE SWING GATE POST & DUCK BILL GENERAL NOTES A.INSTALL FENCE PER ASTM F-567 B.INSTALL SWING GATE PER ASTM F-900 C.LOCAL ORDINANCE OF BARBED WIRE PERMIT REQUIREMENT SHALL BE COMPLIED IF REQUIRED. D.POST & GATE PIPE SIZES ARE INDUSTRY STANDARDS. D.A.ALL PIPES TO BE 1-1/ 2" GALVANIZED (HOT DIP, ASTM A120 GRADE "A" STEEL). D.B.ALL GATE FRAMES SHALL BE WELDED. D.C.ALL WELDING SHALL BE COATED WITH (3) COATS OF COLD GALVANIZED STEEL (OR EQUAL). E. ALL OPEN POSTS SHALL HAVE END-CAPS F. USE GALVANIZED HOG-RING WIRE TO MOUNT ALL SIGNS. G. ALL SIGNS MUST BE MOUNTED ON INSIDE OF FENCE FABRIC. H.CONTRACTOR SHALL PROVIDE AND INSTALL STYMIE-LOCK LOCKING MECHANISM ON 12'-0" GATE. COORDINATE W/ PM FOR FINAL COMBINATION CODE KEYED NOTES 1.CORNER, END OR PULL POST 3" NOMINAL SCHEDULE 40 PIPE. 2.LINE POST: 2-1 /2" SCHEDULED 40 PIPE, PER ASTM-F1083. LINE POSTS SHALL BE EQUALLY SPACED AT MAXIMUM 8'-0" O.C. 3.TOP RAIL & BRACE RAIL: 1-1 /2" PIPE PER ASTM-F1083. 4.FABRIC: 9 GA CORE WIRE SIZE 2" MESH, CONFORMING TO ASTM-A392. ALL PIES TO BE GALVANIZED. 5.TIE WIRE: MINIMUM 11 GA. GALVANIZED STEEL AT POSTS AND RAILS A SINGLE WRAP OF FABRIC TIE AND AT TENSION WIRE BY HOG RINGS SPACED MAXIMUM 24" INTERVALS. 6.TENSION WIRE: 9 GA. GALVANIZED STEEL 7.BARBED WIRE: DOUBLE STRAND 12-1 /2" O.D. TWISTED WIRE TO MATCH WITH FABRIC 14 GA., 4 PT. BARBS SPACED ON APPROXIMATELY 5" CENTERS. 8.STRETCHER BAR 9.3 /8" DIAGONAL ROD WITH GALVANIZED STEEL TURNBUCKLE OR DIAGONAL THREADED ROD. 10.FENCE CORNER POST BRACE: 1-5 /8" DIAMETER EACH CORNER EACH WAY. 11.1-1 /2" MAXIMUM CLEARANCE FROM GRADE. 12.GATE POST 4" SCHEDULE 40 PIPE (FOR GATE WIDTHS UP THRU 7' OR 14' FOR DOUBLE SWING GATES) PER ASTM-F1083. 13.GATE FRAME: 1-1 /2' PIPE, PER ASTM-F1083. 14.GATE FRAME: 1-5 /8" DIAMETER PIPE, PER ASTM-F1083. 15.GATE DIAGONAL GALVANIZED STEEL 1-1 /2" PIPE. 16.DUCK BILL OPEN GATE HOLDER. VERIFY LOCATION IN FIELD PRIOR TO INSTALLATION. 17.LINE POST: CONCRETE FOUNDATION (4000 PSI) 18.CORNER POST: CONCRETE FOUNDATION (4000 PSI) 19.GATE POST: CONCRETE FOUNDATION (4000 PSI) 19 16 1214 13 24 " 10" FINISH GRADE FINISH GRADE 19 METAL GATE DETENT INSTALL W/ SLOT PARALLEL TO FENCE SCALE: NTS GATE DETENT DETAIL SCALE: NTS STYMIELOCK DETAIL CONSTRUCTION DETAILS- FENCE SCALE: NTS STANDARD FENCE ELEVATION XXXXXX XX X X XX X X X XXXX X X X XX X X X XX XXXXX X X X X X X X X XXXXX X X X X X X X X XXXXX XXX X X XXX X X XXXXX X X X X X X X X XXXXX X X X X X X X X X X X 8' - 0 " 7' - 0 " 13'-0" (CENTERED ON FENCE LINE) 10'-0" O.C. MAX. 5'-0" O.C. MIN. 5'-6"5'-6" 12'-6" EQ.EQ. 1 BADF C 1'-6" 3' - 6 " 23 4 9 7 8 610 16 18 J PROPOSED PLUNGER ROD PROPOSED GATE DETENT 5 17 E TOWER COMPANY CONTACT SIGNAGE PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS C-7SCALE: NTS H-FRAME DETAIL 6' - 0 " 4' - 0 " 4" ( T Y P . ) 18" (TYP.) NOTES 1.VERIFY ALL MOUNTING LOCATION PER EQUIPMENT MANUFACTURER FOR LOCATION & QUANITY OF UNISTRUT ON H-FRAME. (MIN. 5 UNISTRUT SHALL BE INSTALLED) 2.ALL EQUIPMENT SHALL BE MOUNTED A MIN. OF 6" ABOVE FINISH GRADE. 3.ALL CONDUIT STUB-UP TO BE ATTACHED NO GREATER HAD 6" MAX. ABOVE FINISHED GRADE. ATTACH ALL CONDUIT ABOVE FIRST 6" AT 12" ON CENTER. 4.BOND ALL METALLIC SURFACES TO GROUND RING WITH #2 SOLID AWG TIN-PLATED COPPER GROUND CONDUCTOR. 5.ALL GROUND LEADS SHALL BE INSTALLED IN 1" SCH. 40 PVC CONDUIT. PROVIDE WATERTIGHT CAULK SEAL & ADEQUATE COIL FOR CONNECT TO PROPOSED EQUIPMENT. WATERTIGHT ENDCAP (TYP.) STANDARD PVC UNISTRUT END-CAP (TYP.) P1000 UNISTRUT SPACED AS REQUIRED, SECURE TO STD, UNISTRUT STRUCTURAL PIPE CONNECTOR FOR V- BOLTS SIZED PER NEED 3" Ø SCH40 GALVANIZED STEEL PIPE MAX @ 72" O.C. FINISH GRADE 4000 PSI CONCRETE POST FOOTING, MIN. (TYP.) 6'-0" MAX. SEE PLAN 6" M I N . COMPOUND FENCE MATERIALS 1' - 0 " 6" 6" 4 5 ° 1'-0" 3' - 6 " 12" 6" FINISH GRADE 1- 1 / 2 " M I N . C L R . 3 - STRAND BARBED WIRE AT FENCE & GATE CHAIN-LINK FENCE FABRIC SCALE: NTS TIE WIRE: MINIMUM 11 GA. GALVANIZED STEEL AT POSTS AND RAILS A SINGLE WRAP OF FABRIC TIE AND AT TENSION WIRE BY HOG RINGS SPACED MAXIMUM 24" INTERVALS. LINE POST EVERY 10'-0" MAX. FILL MATERIAL DEPTH VARIES PER LOCATION. SUBGRADE COMPACTED TO 95% STANDARD PROCTOR PROPOSED 20 MIL. LIGHT WEIGHT WOVEN SLIT FILM POLYPROPYLENE GEOSYNETHIC FABRIC (500X MIRAFI GEOTEXTILE OR EQUAL) PROPOSED 6" FINISH LAYER OF ROLLED #57 STONE 4000 PSI CONCRETE POST FOOTING, MIN. (TYP.) CONSTRUCTION DETAILS- COMPOUND PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS C-8 RADIO FREQUENCY ENVIORMENT AREA RADIO FREQUENCY ENVIORMENT AREA FCC TOWER REGISTRATION NO. 1234567 SITE ID# 000000 VERIFIED 911 STREET ADDRESS CITY, STATE AND ZIP CODE FOR 24 HOUR EMERGENCY SERVICE CALL 1-877-788-7011 FOR LEASE INFORMATION CALL 1-800-788-7011 ASR 1234567 CAUTION NOTICE WARNING THIS SITE IS POSTED & PROTECTED BY RAZOR WIRE VIOLATORS WILL BE PROSECUTED NO TRESPASSING PRIVATE PROPERTY AUTHORIZED PERSONNEL ONLY RED BACKGROUND W/WHITE LETTERINGWARNING HARD HATS REQUIRED WATCH FOR FALLING MATERIAL WATCH FOR TRIPPING HAZARDS WATCH FOR UNEVEN SURFACES IN THE EVENT OF A T-STORM, VACATE THE COMPOUND. WHITE BACKGROUND W/BLACK LETTERING LT. GRAY W/BLACK LETTERING RED BACKGROUND W/WHITE LETTERING WHITE BACKGROUND W/BLACK LETTERING RED BACKGROUND W/WHITE LETTERING WHITE BACKGROUND W/RED LETTERING RED BACKGROUND W/WHITE LETTERING WHITE BACKGROUND W/BLACK LETTERING GREEN BACKGROUND W/WHITE LETTERING YELLOW BACKGROUND W/BLACK LETTERING WHITE BACKGROUND W/BLACK LETTERING AND YELLOW SYMBOL WHITE BACKGROUND W/BLACK LETTERING GENERAL NOTES 18"WIDE x 24" HIGH (A)NO-TRESSPASSING SIGN 18"WIDE x 24" HIGH (B)RAZOR-WIRE SIGN 24"WIDE x 18" HIGH (C)FCC REGISTRATION SIGN 12" WIDE x 18" HIGH (H)CAUTION-RFE SIGN 10" WIDE x 4" HIGH (I)ASR SIGN TO BE MOUNTED NEAR TOWER LEG W/ CLIMBING CABLE. DO NOT RESTRICT CLIMBING ACCESS. NOTES ASR SIGN TO BE MOUNTED AT TOWER BASE DURING CONSTRUCTION. NOTES 24" WIDE x 18" HIGH (D)MARKETING/ ID SIGN 24" WIDE x 18" HIGH (E)CAUTION - HARD HAT CONSTUCTION AREA AND TRIPPING HAZARDS 24" WIDE x 18" HIGH (F)NOTICE-RFE SIGN SIGN DETAILS 1.THE SITE SHALL ONLY CONTAIN SIGNAGE AS MANDATED BY THE FCC 2.ALL SIGNS TO BE INSTALLED ACCORDING TO DWG SITE SIGNAGE ADJACENT TO GATES (LEFT OR RIGHT SIDE OF GATE IS ACCEPTABLE, BUT MUST BE MOUNTED ON GATE SIDE OF COMPOUND, SO AS TO BE READABLE WITH GATES OPEN OR CLOSED). 3.SIGNS SHALL BE FABRICATED FROM CORROSION RESISTANT PRESSED METAL, AND PAINTED WITH LONG LASTING UV RESISTANT COATING. 4.SIGNS (EXCEPT WHERE NOTED OTHERWISE) SHALL BE MOUNTED TO THE TOWER, GATE AND FENCE USING A MIN. OF 9 GAUGE ALUMINUM WIRE, HOG RINGS (AS UTILIZED IN FENCE INSTALLATIONS) OR BRACKETS WHERE NECESSARY. BRACKETS SHALL BE OF SIMILAR METAL AS THE STRUCTURE TO AVOID GALVANIC CORROSION. 5.ADDITIONAL E911 ADDRESS SIGNS ARE REQUIRED AT EACH ACCESS ROAD GATE LEADING TO THE COMPOUND AS WELL AS ON THE COMPOUND GATE ITSELF. 6.ADDITIONAL FCC RESTRATION # SIGNS ARE REQUIRED AT EACH ACCESS ROAD GATE LEADING TO THE COMPOUND AS WELL AS ON THE COMPOUND GATE ITSELF. SIGN SHALL MEASURE 20" LONG x 4" TALL). THE LETTERS SHALL BE 1" AND THE NUMBERS SHALL BE 2". 7.CTG TO ORDER AND SHIP SIGNS TO GENERAL CONTRACTOR'S OFFICE. GENERAL CONTRACTOR TO INSTALL SIGNS. PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS C-9 FOUNDATION, EXCAVATION & GRADING NOTES 1.ALL CUT AND FILL SLOPES SHALL BE 2 : 1 MAXIMUM. 2.ALL EXCAVATIONS ON WHICH CONCRETE IS TO BE PLACED SHALL BE SUBSTANTIALLY 3.HORIZONTAL ON UNDISTURBED AND UNFROZEN SOIL AND BE FREE FROM LOOSE MATERIAL AND EXCESS GROUND WATER. DEWATERING FOR EXCESS GROUND WATER SHALL BE PROVIDED IF REQUIRED. 4.CONCRETE FOUNDATIONS SHALL NOT BE PLACED ON ORGANIC MATERIAL. IF SOUND SOIL IS NOT REACHED AT THE DESIGNATED EXCAVATION DEPTH, THE UNSATISFACTORY SOIL SHALL BE EXCAVATED TO ITS FULL DEPTH AND EITHER BE REPLACED WITH MECHANICALLY COMPACTED GRANULAR MATERIAL OR THE EXCAVATION SHALL BE FILLED WITH CONCRETE OF THE SAME QUALITY SPECIFIED FOR THE FOUNDATION. 5.ANY EXCAVATION OVER THE REQUIRED DEPTH SHALL BE FILLED WITH EITHER MECHANICALLY COMPACTED GRANULAR MATERIAL OR CONCRETE OF THE SAME QUALITY SPECIFIED FOR THE FOUNDATION. CRUSHED STONE MAY BE USED TO STABILIZE THE BOTTOM OF THE EXCAVATION. STONE, IF USED, SHALL NOT BE USED AS COMPILING CONCRETE THICKNESS. 6.AFTER COMPLETION OF THE FOUNDATION AND OTHER CONSTRUCTION BELOW GRADE, AND 5. BEFORE BACK FILLING, ALL EXCAVATIONS SHALL BE CLEAN OF UNSUITABLE MATERIAL SUCH AS VEGETATION, TRASH, DEBRIS, AND SO FORTH. 7.ALL BACKFILLING SHALL (1) USE APPROVED MATERIALS CONSISTING OF EARTH, LOAM, 6. SANDY CLAYS, SAND AND GRAVEL, OR SOFT SHALE, (2) BE FREE FROM CLODS OR STONES OVER 2 1/2" MAXIMUM DIMENSIONS, AND (3) BE PLACED IN LAYERS AND COMPACTED. 8.SITE FILL MATERIAL AND FOUNDATION BACK FILL SHALL BE PLACED IN LAYERS, MAXIMUM 6" 7. DEEP BEFORE COMPACTION. EACH LAYER SHALL BE SPRINKLED IF REQUIRED AND COMPACTED BY HAND OR MACHINE TAMPERS TO 95% OF MAXIMUM DENSITY, AT THE OPTIMUM MOISTURE CONTENT OF ±2% AS DETERMINED BY ASTM DESIGNATION D-698, UNLESS OTHERWISE APPROVED. SUCH BACK FILL SHALL NOT BE PLACED BEFORE 3 DAYS AFTER PLACEMENT OF CONCRETE. 9.THE FOUNDATION AREA SHALL BE GRADED TO PROVIDE WATER RUNOFF AND PREVENT 8. WATER FROM STANDING. THE FINAL GRADE SHALL SLOPE AWAY IN ALL DIRECTIONS FROM THE FOUNDATION AREA (UP TO 1 FOOT OUTSIDE THE FENCE OR GROUND SYSTEM PERIMETER) AND SHALL BE COVERED WITH A GEOTEXTILE FABRIC MIRAFI 500X OR APPROVED EQUAL TO PREVENT REOCCURRENCE OF VEGETATIVE GROWTH, AN THEN SHALL BE COVERED WITH 4" DEEP COMPACTED STONE OR GRAVEL. 10.THE CONTRACTOR SHALL PROVIDE ALL EROSION AND SEDIMENTATION CONTROL MEASURES 9. AS REQUIRED BY LOCAL, CITY, COUNTY, AND STATE CODES AND ORDINANCES TO PROTECT EMBANKMENTS FROM SOIL LOSS AND TO PREVENT ACCUMULATION OF SOIL AND SILT IN STREAMS AND DRAINAGE PATHS FROM LEAVING THE CONSTRUCTION AREA. THIS MAY INCLUDE SUCH MEASURES AS SILT FENCES, STRAW BALE SEDIMENT BARRIERS, AND CHECK DAMS. 11.FILL PREPARATION: REMOVE ALL VEGETATION, TOPSOIL, DEBRIS, WET AND UNSATISFACTORY SOIL MATERIALS, OBSTRUCTIONS, AND DELETERIOUS MATERIAL FROM GROUND SURFACE PRIOR TO PLACING FILLS. PLOW STRIP OR BREAK UP SLOPED SURFACES STEEPER THAN 1 VERTICAL TO 4 HORIZONTAL SO FILL MATERIAL WILL BOND WITH EXISTING SURFACE. WHEN SUBGRADE OR EXISTING GROUND SURFACE TO RECEIVE FILL HAS A DENSITY LESS THAN THAT REQUIRED FOR FILL, BREAK UP GROUND SURFACE TO REQUIRED DEPTH, PULVERIZE, MOISTURE CONDITION OR AERATE SOIL, AND RECOMPACT TO REQUIRED DENSITY. 12.REPLACE EXISTING GRAVEL SURFACING ON AREAS FROM WHICH GRAVEL SURFACING IS REMOVED DURING CONSTRUCTION OPERATIONS. GRAVEL SURFACING SHALL BE REPLACED TO MATCH EXISTING ADJACENT GRAVEL SURFACING AND SHALL BE OF THE SAME THICKNESS. SURFACES AND GRAVEL SURFACING SHALL BE FREE FROM CORRUGATIONS AND WAVES. EXISTING GRAVEL SURFACING MAY BE EXCAVATED SEPARATELY AND REUSED IF INJURIOUS AMOUNTS OF EARTH, ORGANIC MATTER, OR OTHER DELETERIOUS MATERIALS ARE REMOVED PRIOR TO REUSE. FURNISH ALL ADDITIONAL GRAVEL RESURFACING MATERIAL AS REQUIRED. BEFORE GRAVEL SURFACING IS REPLACED, SUBGRADE SHALL BE GRADED TO CONFORM TO REQUIRED SUBGRADE ELEVATIONS, AND LOOSE OR DISTURBED MATERIALS SHALL BE THOROUGHLY COMPACTED. DEPRESSIONS IN THE SUBGRADE SHALL BE FILLED AND COMPACTED WITH APPROVED SELECTED MATERIAL. GRAVEL SURFACING MATERIAL SHALL NO BE USED FOR FILLING DEPRESSIONS IN THE SUBGRADE. 13.PROTECT EXISTING GRAVEL SURFACING AND SUBGRADE IN AREAS WHERE EQUIPMENT LOADS WILL OPERATE. USE PLANKING OR OTHER SUITABLE MATERIALS DESIGNED TO SPREAD EQUIPMENT LOADS. REPAIR ANY DAMAGE TO EXISTING GRAVEL SURFACING OR SUBGRADE WHERE SUCH DAMAGE IS DUE TO THE CONTRACTOR'S OPERATIONS. ENSURE POSITIVE DRAINAGE DURING AND AFTER COMPLETION OF CONSTRUCTION. 14.RIPRAP SHALL BE CLEAN, HARD, SOUND, DURABLE, UNIFORM IN QUALITY, AND FREE OF ANY 14. DETRIMENTAL QUANTITY OF SOFT, FRIABLE, THIN, ELONGATED OR LAMINATED PIECES, DISINTEGRATED MATERIAL, ORGANIC MATTER, OIL, ALKALI, OR OTHER DELETERIOUS SUBSTANCE. 15.REMOVE ALL ORGANICS, ROCKS GREATER THAN 3", UNUSED FILL AND OTHER DEBRIS TO AN 15. AREA OFF SITE IN A LEGAL MANNER FOUNDATION, EXCAVATION & GRADING NOTES 18 " M I N 6" 2" 4'-0" MAX. 18 " M I N FLOW 30 " M I N 28 " 30 " M I N 28 " WOVEN WIRE FENCE BACKING GEOTEXTILE UNDERLINER COARSE AGGREGATE N.S.A. R-2(1.5"-3.5") 20' M I N I M U M 50' M I N I M U M 30' M I N I M U M EXIST I N G P A V E M E N T 6" M I N I M U M (WITH PERMANENT VEGETATION) DISTURBED AREA STABILIZATION (WITH TEMPORARY SEEDING) DISTURBED AREA STABILIZATION Ds3 Ds2 SCALE: NTS CO-CONSTRUCTION EXIT DETAIL 1.PERIODICALLY DRESS WITH 1.5"-3.5" STONE. 2.MAINTAIN IN A CONDITION THAT WILL PREVENT TRACKING OR FLOW OF MUD ONTO PUBLIC RIGHTS-OF-WAY. 3.IMMEDIATELY REMOVE MUD AND DEBRIS TRACKED OR SPILLED ONTO ROADWAYS. MAINTENANCE SCALE: NTS SFC-SILT FENCE, TYPE-C FILTER FABRIC MATERIAL STEEL POST BURY BOTTOM OF FILTER MATERIAL IN 6" TRENCH FILTER FABRIC STEEL POST1.USE 36" DOT APPROVED FABRIC 2.USE STEEL POSTS NOTES GRADING NOTES & DETAILS PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS C-10 EROSION & SEDIMENT CONTROL NOTES 1.COMPOUND SHALL BE RELATIVELY FLAT. CONTRACTOR TO PROVIDE POSITIVE DRAINAGE. 2.DISTURBED AREAS LEFT IDLE SHALL BE STABILIZED WITH TEMPORARY VEGETATION AFTER 14 DAYS; AFTER 30 DAYS PERMANENT VEGETATION SHALL BE ESTABLISHED. 3.PRIOR TO COMMENCING LAND DISTURBANCE ACTIVITIES, THE LIMITS OF THE DISTURBANCE SHALL BE CLEARLY DEMARCATED WITH STAKES, RIBBONS, OR OTHER APPROPRIATE MEANS. 4.THE CONSTRUCTION OF THE SITE WILL INITIATE WITH THE INSTALLATION OF EROSION CONTROL MEASURES SUFFICIENT TO CONTROL SEDIMENT DEPOSITS AND EROSION. CONTRACTOR SHALL CALL APPROPRIATE COUNTY FOR AN INSPECTION OF SOIL EROSION CONTROL MEASURES PRIOR TO BEGIN GRADING ACTIVITY. ALL SEDIMENT CONTROL WILL BE MAINTAINED UNTIL ALL UPSTREAM GROUND WITHIN THE CONSTRUCTION AREA HAS BEEN COMPLETELY STABILIZED. 5.THE LOCATION OF SOME OF THE EROSION CONTROL DEVICES MAY HAVE TO BE ALTERED FROM THAT SHOWN ON THE PLANS IF DRAINAGE PATTERNS DURING CONSTRUCTION ARE DIFFERENT FROM THE FINAL PROPOSED DRAINAGE SYSTEMS. ANY DIFFICULTY IN CONTROLLING EROSION DURING ANY PHASE OF CONSTRUCTION SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 6.EROSION CONTROL MEASURES WILL BE MAINTAINED AT ALL TIMES IF FULL IMPLEMENTATION OF THE APPROVED PLAN DOES NOT PROVIDE FOR ELECTIVE EROSION CONTROL, ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE IMPLEMENTED TO CONTROL OR TREAT THE SEDIMENT SOURCE. 7.THE CONTRACTOR SHALL REMOVE ACCUMULATED SILT WHEN THE SILT IS WITHIN 12" OF THE TOP OF THE SILT FENCE. 8.FAILURE TO INSTALL, OPERATE OR MAINTAIN ALL EROSION CONTROL MEASURES WILL RESULT IN ALL CONSTRUCTION BEING STOPPED ON THE JOB SITE UNTIL SUCH MEASURES ARE CORRECTED. 9.ANY DISTURBED AREA LEFT EXPOSED FOR A PERIOD GREATER THAN 7 DAYS SHALL BE STABILIZED WITH SEEDING. 10.CONTRACTOR SHALL REMOVE ALL EROSION CONTROL MEASURES AFTER COMPLETION OF CONSTRUCTION AND ESTABLISHMENT OF PERMANENT GROUND COVER. 11.THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE PREVENTED BY THE INSTALLATION OF EROSION CONTROL MEASURES AND PRACTICES PRIOR TO, OR CONCURRENT WITH, LAND-SIDTURBING ACTIVITIES. 12.ALL CUT AND FILL SLOPES MUST BE SURFACED ROUGHENED AND VEGETATED WITHIN SEVEN (7) DAYS OF THEIR CONSTRUCTION. 13.ALL FILL SLOPES WILL HAVE SILT FENCES AT THE TOE OF THE SLOPE. 14.ALL SEDIMENT AND EROSION CONTROL MEASURES WILL BE CHECKED DAILY AND ANY DEFICIENCIES NOTED WILL BE CORRECTED BY THE END OF EACH DAY. ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES WILL BE INSTALLED IF DEEMED NECESSARY AFTER ON-SITE INSPECTION BY THE ISSUING AUTHORITY. 15.A 25' MIN. UNDISTURBED VEGETATION BUFFER ADJ. TO ALL RUNNING STREAMS AND CREEKS WILL BE LEFT AND MAINTAINED. 16.MAINTENANCE STATEMENT: EROSION CONTROL MEASURES WILL BE INSPECTED AT LEAST WEEKLY, AFTER EACH RAIN AND REPAIRED BY THE GENERAL CONTRACTOR. 17.ADDITIONAL EROSION CONTROL MEASURES WILL BE INSTALLED IF DEEMED NECESSARY BY ON-SITE INSPECTIONS. 18.CONSTRUCTION EXIT - TO REDUCE OR ELIMINATE THE TRANSPORT OF MUD FROM THE CONSTRUCTION AREA ONTO PUBLIC RIGHT-OF-WAYS, STREETS, ALLEYS, SIDEWALKS, OR PARKING AREAS. IMMEDIATELY REMOVE MUD AND DEBRIS TRACKED OR SPILLED ONTO ROADWAYS. 19.TYPE C SEDIMENT BARRIER - TO PREVENT ANY SEDIMENT CARRIED BY SHEET FLOW FROM LEAVING THE SITE AND ENTERING NATURAL DRAINAGE WAYS OR STORM DRAINAGE SYSTEMS. 20.DISTURBED AREA STABILIZATION (TEMPORARY) - TO ESTABLISH A TEMPORARY VEGETATIVE COVER WITH FAST GROWING SEEDINGS ON DISTURBED AREAS. 21.DISTURBED AREA STABILIZATION (PERMANENT) - TO ESTABLISH A PERMANENT VEGETATIVE COVER SUCH AS TREES, SHRUBS, VINES, GRASSES, SOD, OR LEGUMES ON DISTURBED AREAS. 22.DISTURBED AREA DUST CONTROL- TO CONTROL THE SURFACE AND AIR MOVEMENT OF DUST ON CONSTRUCTION SITES, ROADWAYS, AND SIMILAR SITES. A.USE OF SWALES AND/OR DRAINAGE DITCHES FOR PROPER WATER RUNOFF AS NEEDED. B.AGGREGATE IS BASED ON STANDARD AASHTO. C.SLOPE NOT TO EXCEED 1/4" PER FOOT TO MAX. GRADE OF 6" FROM CENTER OF COMPOUND TO EACH FENCE LINE. D.SUB-GRADE SHALL BE COMPACTED BY SHEEPS FOOT VIBRATOR OR RUBBER TIRED ROLLERS WEIGHING AT LEAST EIGHT TONS. E.FINISHED GRADE SHALL BE COMPACTED BY SMOOTH DRUM VIBRATOR ROLLERS WEIGHING AT LEST EIGHT TONS. FINISHED GRADE SHALL BE UNIFORM AND LEVEL. F.GRADING IS REQUIRED FOR THE PROPOSED CONSTRUCTION. COMPOUND SHALL BE RELATIVELY FLAT. CONTRACTOR TO PROVIDE POSITIVE DRAINAGE. G.DISTURBED AREAS LEFT IDLE SHALL BE STABILIZED WITH TEMPORARY VEGETATION AFTER 14 DAYS; AFTER 30 DAYS PERMANENT VEGETATION SHALL BE ESTABLISHED. H.MAINTENANCE STATEMENT: EROSION CONTROL MEASURES WILL BE INSPECTED AT LEAST WEEKLY, AFTER EACH RAIN AND REPAIRED BY THE GENERAL CONTRACTOR. I.ADDITIONAL EROSION CONTROL MEASURES WILL BE INSTALLED IF DEEMED NECESSARY BY ON-SITE INSPECTIONS. J.CONSTRUCTION EXIT - TO REDUCE OR ELIMINATE THE TRANSPORT OF MUD FROM THE CONSTRUCTION AREA ONTO PUBLIC RIGHT-OF-WAYS, STREETS, ALLEYS, SIDEWALKS, OR PARKING AREAS. IMMEDIATELY REMOVE MUD AND DEBRIS TRACKED OR SPILLED ONTO ROADWAYS. K.TYPE C SEDIMENT BARRIER - TO PREVENT ANY SEDIMENT CARRIED BY SHEET FLOW FROM LEAVING THE SITE AND ENTERING NATURAL DRAINAGE WAYS OR STORM DRAINAGE SYSTEMS. L.DISTURBED AREA STABILIZATION (TEMPORARY) - TO ESTABLISH A TEMPORARY VEGETATIVE COVER WITH FAST GROWING SEEDINGS ON DISTURBED AREAS. M.DISTURBED AREA STABILIZATION (PERMANENT) - TO ESTABLISH A PERMANENT VEGETATIVE COVER SUCH AS TREES, SHRUBS, VINES, GRASSES, SOD, OR LEGUMES ON DISTURBED AREAS. CONTRACTOR TO INSTALL SOD TO MATCH THE SPECIES USED BY THE UNIVERSITY OF HOUSTON. N.DISTURBED AREA DUST CONTROL - TO CONTROL THE SURFACE AND AIR MOVEMENT OF DUST ON CONSTRUCTION SITES, ROADWAYS, AND SIMILAR SITES. EROSION & SEDIMENT CONTROL NOTES EROSION & SEDIMENT CONTROL COMPOUND NOTES GRADING NOTES & DETAILS X PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS C-11 GRAPHIC SCALE NORTH ARROW W N EMP A& S 00' SCALE: 1" = 40' 40'40' THE PRE-DEVELOPED IMPERVIOUS AREA IS 0 SF AND POST-DEVELOPED IMPERVIOUS AREA IS 4,295 SF. THE RELATIVELY SMALL (4,295 SF OR 1.66%) INCREASE IN IMPERVIOUS AREA SHOULD NOT SUBSTANTIALLY PRODUCE AN INCREASE IN RUNOFF VOLUME OR RUNOFF FLOW RATE. ALLOWING THE RUNOFF TO CONTINUE TO SHEET FLOW OVER GRAVEL AND EXISTING PREVIOUS SURFACE WILL ALLOW ANY INCREASE TO INFILTRATE INTO THE GROUND. CALCULATIONS (AT BUILDING PERMIT APPLICATION) WILL BE PROVIDED TO DEMONSTRATE NO ADVERSE IMPACTS TO THE EXISTING STORM SYSTEM DOWNSTREAM. STORM WATER CALCS IMPERVIOUS SURFACE RATIOS/IMPACT TABLE GRADING & EROSION CONTROL PLAN SFC 2% SILT FENCE/LIMITS OF CONSTRUCTION 9.25' 8.00' 9.25' 9.25' 9.75' 9.25' 2% 1% FILL VOLUME CALCS DIRT :(42FT)(40FT)(1.5FT)-CONCRETE SQFT(1.5FT)= 2520- 133.17= 2386.83 CF -ADD CLEAN DIRT FILL TO ENTIRE SITE AREA TO RAISE SITE 18". INSTALL FILL DIRT & PACK IN 12" LIFTS TO COMPACTED AT A MIN. OF 98% STANDARD PROCTOR. ALL IMPORTED FILL SHOULD BE CLEAN SOIL (FREE OF ROOTS & DEBRIS AND SHOULD CONTAIN LESS THAN 10% BY DRY WEIGHT PASSING #200. DO NOT REUSE ANY EXISTING EXCAVATED SOILS FOR STRUCTURAL FILL. GRAVEL:(42FT)(40FT)(0.5FT)-CONCRETE SQFT(0.5FT) + GRAVEL DRIVE@1968 (RAISED 0.5FT)=840-44.39+1968= 2,763.61 CF -USE ROLLED 6" #57 STONE AS SHOWN ON SHEET C-7 CONCRETE:(TOWER FOUNDATION + 22 CONCRETE POST) @ 2' = 177.56 CF -TOWER FOUNDATION IS 10' IN DIAMETER= 50.26(2')= 100.52 -FENCE POST (TYP. 20) ARE 12" IN DIAMETER= 31.4(2')=62.8 -POST FOR H-FRAME (TYP. 2) ARE 18" IN DIAMETER=7.12(2')=14.24 - TOTAL FILL VOLUME =5328 CF GRAVEL DRIVE/ COMPOUND FOR FILL VOLUME CALCULATIONS AND IMPERVIOUS SURFACE RATIOS SEE NOTES AT THE BOTTOM OF THIS SHEET (C-11) JURISDICTIONAL WETLAND CONCRETE FOUNDATION SCALE: NTS HATCH LEGEND SCALE: NTS COMPOUND FILL TYPES DIRT FILL (1.5' IN DEPTH) BENEATH GRAVEL WITHIN COMPOUND CONCRETE FOUNDATIONS FOR FENCE POST, H-FRAME AND TOWER GRAVEL ACCESS DRIVE AND GRAVEL OVERLAY FOR COMPOUND (6" IN DEPTH) EXISTING TRACT SIZE:259,182 SQ.FT. (5.95 ACRES) LIMIT OF CONSTRUCTION:4,158 SQ. FT (0.095 ACRES) EXISTING PERVIOUS/ IMPERVIOUS AREA TOTAL EXISTING PERVIOUS AREA:259,182 SQFT. (5.95 ACRES) TOTAL EXISTING IMPERVIOUS AREA:0000 SQFT. (.000 ACRES) PROPOSED IMPERVIOUS AREA 3,732 SQFT.(0.085 ACRES) PROPOSED IMPERVIOUS AREA INCREASE: COMPOUND 1,676 SQFT. (0.04 ACRES) GRAVEL DRIVE 2,056 SQFT.(0.05 ACRES) TOTAL PROPOSED PERVIOUS AREA:255,450 SQFT. (5.86 ACRES) PROPOSED IMPERVIOUS AREA:3,732 SQFT. (0.085 ACRES) IMPERVIOUS SURFACE AREA (ISR) & PERVIOUS SURFACE AREA (PSR) PROPOSED ISR: 3,732/ 259,182 = 1.439% PROPOSED PSR:255,450/ 259,182 =98.560% FILL VOLUMES BFE = 9'EX. GRADE = 7'MITIGATION= BFE - GRADE = 2' PROPOSED FILL VOLUME (DIRT): 2386.83 CUBIC FT. PROPOSED FILL VOLUME (GRAVEL): 2763.61 CUBIC FT. PROPOSED FILL VOLUME (CONCRETE): 177.56 CUBIC FT. GRAVEL ACCESS DRIVE AND GRAVEL OVERLAY FOR COMPOUND (6" IN DEPTH) PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS C-12 LANDSCAPING PLAN NORTH ARROW W N EMP A& S GENERAL NOTES 00' SCALE: 1" = 40' 1.ALL PLANTS MUST BE HEALTHY, VIGOROUS MATERIAL, FREE OF PESTS AND DISEASE. 2.PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL AVOID DAMAGE TO ALL UTILITIES DURING COURSE OF THE WORK. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ALL DAMAGE TO UTILITIES, STRUCTURES, SITE APPURTENANCES, ETC. WHICH OCCURS AS A RESULT OF THE LANDSCAPE CONSTRUCTION. 3.THE CONTRACTOR SHALL COMPLETELY GUARANTEE ALL PLANT (1) YEAR BEGINNING AT THE DATE OF TOTAL ACCEPTANCE. THE CONTRACTOR SHALL PROMPTLY MAKE ALL REPLACEMENTS BEFORE OR AT THE END OF THE GUARANTEE PERIOD. 4.ANY PLANT MATERIAL THAT DIES, TURNS BROWN OR DEFOLIATES (PRIOR TO TOTAL ACCEPTANCE OF THE WORK) SHALL BE PROMPTLY REMOVED FROM THE SITE AND REPLACED WITH MATERIAL OF THE SAME SPECIES, QUANTITY, SIZE AND MEETING ALL SPECIFICATIONS. 5.STANDARDS SET FORTH IN "AMERICAN STANDARD FOR NURSERY STOCK", LATEST EDITION, REPRESENT GUIDELINE SPECIFICATIONS ONLY AND SHALL CONSTITUTE MINIMUM QUALITY REQUIREMENTS FOR PLANT MATERIAL. 6.ALL BUFFERS AND TREE SAVE AREAS ARE TO BE CLEARLY IDENTIFIED WITH FLAGGING AND /OR FENCING PRIOR TO COMMENCEMENT OF ANY LAND DISTURBANCE 6.0' 2" M A X . STAY OUTTREE SAVE AREA 1.NO SPECIMEN TREES EXISTING ON THE SITE. 2.NO PLANTING MATERIAL WILL BE STORED ON SITE. 3.THERE WILL NO BURNING OR BURIAL OF DEBRIS ON SITE. ARBORIST NOTES SCALE: NTS TREE PROTECTION DETAIL GRAPHIC SCALE SCALE: 1:40 LANDSCAPING PLAN BRIGHT ORANGE POLYTHYLENE LAMINAR FENCE FABRIC 4' - 0 " 2' - 0 " FENCE LOCATION (LIMITS OF CRITICAL ROOT ZONE OR AS SHOWN ON PLANS. "TREE SAVE AREA" SIGNAGE EVERY 20'-0" METAL STAKE (TYP.) PROPOSED CANISTER TOWER 40'40' PROPOSED 6" OF #57 STONE ON GEOSYNTHETIC FABRIC PROPOSED 25' LANDSCAPE BUFFER/ TREE PRESERVATION AREA (SUSTAIN/PROTECT EXISTING TREES) PROPOSED 6" OF #57 STONE ON GEOSYNTHETIC FABRIC PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS E-1 ELECTRICAL NOTES ELECTRICAL INSTALLATION NOTES 1.ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE LOCAL CODES. 2.CONDUIT ROUTINGS ARE SCHEMATIC. SUBCONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED. 3.WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC AND TELCORDIA. 4.ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC AND TELCORDIA. 5.CABLES SHALL NOT BE ROUTED THROUGH LADDER-STYLE CABLE TRAY RUNGS. 6.EACH END OF EVERY POWER, POWER PHASE CONDUCTOR (I.E., HOTS), GROUNDING, AND T1 CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR-CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2 INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC & OSHA. 7.ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. ALL EQUIPMENT SHALL BE LABELED WITH THEIR VOLTAGE RATING, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING, AND BRANCH CIRCUIT ID NUMBERS (I.E., PANELBOARD AND CIRCUIT ID'S). 8.PANELBOARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) SHALL BE CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. 9.ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. 10.POWER, CONTROL, AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR (#14 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90 °C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, UNLESS OTHERWISE SPECIFIED. 11.SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR (#6 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2 GREEN INSULATION, CLASS B STRANDED COPPER CABLE RATED FOR 90 °C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, UNLESS OTHERWISE SPECIFIED. 12.POWER AND CONTROL WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI-CONDUCTOR, TYPE TC CABLE (#14 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90 °C (WET AND DRY) OPERATION; WITH OUTER JACKET; LISTED OR LABELED FOR THE LOCATION USED, UNLESS OTHERWISE SPECIFIED. 13.ALL POWER AND POWER GROUNDING CONNECTIONS SHALL BE CRIMP-STYLE, COMPRESSION WIRE LUGS AND WIRENUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRENUTS SHALL BE RATED FOR OPERATION AT NO LESS THAN 75°C (90°C IF AVAILABLE). 14.RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE, AND NEC. 15.ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40, OR RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 16.ELECTRICAL METALLIC TUBING (EMT), ELECTRICAL NONMETALLIC TUBING (ENT), OR RIGID NONMETALLIC CONDUIT (RIGID PVC, SCHEDULE 40) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 17.GALVANIZED STEEL INTERMEDIATE METALLIC CONDUIT (IMC) SHALL BE USED FOR OUTDOOR LOCATIONS ABOVE GRADE. 18.RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40 OR RIGID PVC SCHEDULE 80) SHALL BE USED UNDERGROUND; DIRECT BURIED, IN AREAS OF OCCASIONAL LIGHT VEHICLE TRAFFIC OR ENCASED IN REINFORCED CONCRETE IN AREAS OF HEAVY VEHICLE TRAFFIC. 19.LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 20.CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND APPROVED FOR THE LOCATION USED. SETSCREW FITTINGS ARE NOT ACCEPTABLE. 21.CABINETS, BOXES, AND WIREWAYS SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE, AND NEC. 22.WIREWAYS SHALL BE EPOXY-COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARD; SHALL BE PANDUIT TYPE E (OR EQUAL); AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS. 23.EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED OR EPOXY-COATED SHEET STEEL, SHALL MEET OR EXCEED UL 50, AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS 24.METAL RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL BE GALVANIZED, EPOXY-COATED, OR NON-CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1; AND RATED NEMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. 25.NONMETALLIC RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND RATED NEMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. 26.THE SUBCONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CONTRACTOR BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 27.THE SUBCONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD AGAINST LIFE AND PROPERTY. ELECTRICAL INSTALLATION NOTES CONT.GROUNDING GENERAL NOTES A.ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION, AND AC POWER GES'S) SHALL BE BONDED TOGETHER, AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC AND AT&T ND-00071. B.THE SUBCONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. C.METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS. D.CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK-TO-BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. E.ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. F.USE OF 90 BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45 BENDS CAN BE ADEQUATELY SUPPORTED. IN ALL CASES, BENDS SHALL BE MADE WITH A MINIMUM BEND RADIUS OF 8 INCHES. G.ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING, SHALL BE #2 AWG SOLID TIN-PLATED COPPER UNLESS OTHERWISE INDICATED. H.EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. CONNECTIONS TO ABOVE GRADE EXTERIOR UNITS SHALL BE MADE WITH EXOTHERMIC WELDS WHERE PRACTICAL OR WITH 2 HOLE MECHANICAL TYPE BRASS CONNECTORS WITH STAINLESS STEEL HARDWARE, INCLUDING SET SCREWS. I.EXOTHERMIC WELDS SHALL BE PERMITTED ON TOWERS ONLY WITH THE EXPRESS APPROVAL OF THE TOWER MANUFACTURER OR THE CONTRACTORS STRUCTURAL ENGINEER. J.ALL WIRE TO WIRE GROUND CONNECTIONS TO THE INTERIOR GROUND RING SHALL BE FORMED USING HIGH PRESS CRIMPS OR SPLIT BOLT CONNECTORS WHERE INDICATED IN THE DETAILS. K.APPROVED ANTIOXIDANT COATINGS (I.E., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. L.ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. M.MISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. N.BOND ALL METALLIC OBJECTS WITHIN 6 FT OF THE BURIED GROUND RING WITH # 2 SOLID AWG TIN-PLATED COPPER GROUND CONDUCTOR. O.GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC PLASTIC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (E.G., STEEL CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT WITH LISTED BONDING FITTINGS. PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS E-2 ELECTRICAL ONE-LINE FROM LOCAL UTILITY 200A 200A 200A "CARRIER" "CARRIER" "CARRIER" GENERAL NOTES 1.ELECTRICAL CONTRACTOR SHALL CONTACT POWER CO. & FIBER CO. AND VERIFY EXACT ROUTING, SIZING AND CONDITIONS BEFORE TRENCHING. 2.INSTALL ALL CONDUITS & EQUIPMENT AS SPECIFIED BY POWER CO. & FIBER CO. 3.VERIFY ALL EXISTING UNDERGROUND UTILITIES BEFORE TRENCHING. 4.PROVIDE NYLON PULL STRINGS ON ALL EMPTY CONDUITS. CONDUIT & RISER DIAGRAM NOTE ALL RISER POLE CONDUIT SHALL BE SUPPLIED BY THE OWNER/DEVELOPER AND MUST BE ON THE JOB SITE. THE OWNER/DEVELOPER SHALL INSTALL THE BOTTOM JOINT OF GALVANIZED RIGID STEEL CONDUIT AND POWER COMPANY WILL INSTALL THE TOP TWO (2) JOINTS. THE BOTTOM JOINT OF CONDUIT AND 90 DEGREE ELBOW SHALL BE INSTALLED BY THE CONTRACTOR AFTER POWER CO. INSTALLS THE RISER POLE. THE CONTRACTOR MUST ALSO SUPPLY SIX (6) TWO HOLE RIGID STEEL STRAPS (2 STRAPS PER 10 FT JOINT) GROUND CLAMP WILL BE PROVIDED AND INSTALLED BY POWER CO. MULTI-GANG METER NOTES: EATON MODEL # 1MP6206RRLBC A.THE SERVICE BOX SHALL BE LOCKABLE WITH PROVISIONS TO ACCEPT THE UTILITY LOCKS. B.COVERS SHALL BE FASTENED WITH MACHINE SCREWS OR BOLTS. HINGED COVERS SHALL NOT BE PERMITTED. C.COVERS SHALL HAVE TWO HANDLES FOR REMOVAL. D.THE SERVICE CABLE TAP BOX SHALL BE IN COMPLIANCE WITH UTILITY SERVICE STANDARDS. SCALE: NTS ONE-LINE DIAGRAM INSTALL NAME PLATE WITH 3/8" MINIMUM HEIGHT LETTERS ON METER SOCKETCONDUCTORS SIZED PER UTILITY COMPANY REQUIREMENTS AND LENGTH OF FINAL RUN TO SOURCE OF SERVICE. THE CONTRACTOR SHALL SUPPLY AND INSTALL THE WEATHER-HEAD IF REQUIRED. STEP DOWN TRANSFORMER BY LOCAL UTILITY 120/208V, SINGLE PHASE, 3 WIRE, 60 HZ. VERIFY LOCATION WITH SERVICE PROVIDER. MOUNTED ON POLE OVERHEAD. 2 SETS OF (3)#350KCMIL IN 2" CONDUIT PARALLEL RUNS PROVIDE SERVICE ENTRANCE GROUND ROD WITH INSPECTION WELL IN ACCORDANCE WITH NEC 250 AND LOCAL UTILITY REQUIREMENTS 800AMP 4-GANG METER PANEL INSTALLED BY CONTRACTOR. COORDINATE WITH UTILITY COMPANY FOR MANUFACTURER AND MODEL. SEE MULTI-GANG METER NOTES FOR SPECIFICATION (OR EQ./SIMILAR) TO CARRIER LEASE AREA 200A "CARRIER" PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS E-3 GROUNDING PLAN NORTH ARROW W N EMP A& S KEYED NOTES 00' SCALE: 1" = 10' GRAPHIC SCALE GRAPHIC LEGEND EXOTHERMIC WELD 5/8" X 10' COPPER CLAD GROUND ELECTRODE MECHANICAL CONNECTION 5/8" X 10' COPPER CLAD GROUND ELECTRODE W/ INSPECTION WELL 10'10' 1.#2 AWG BARE TINNED SOLID COPPER EQUIPMENT GROUND RING BURIED 30" BELOW GRADE OR 6" BELOW FROST LINE(WHICHEVER IS GREATER, TYP.) ALL GROUND LEADS CONNECTED TO RING SHALL BE #2 AWG BARE TINNED SOLID COPPER. 2.BOND EACH TOWER GROUND TEST WELL AROUND THE TOWER TO GROUND STABS ON TOWER AT 48" ABOVE FINISHED GRADE (TYP. 3) 3.PROPOSED 5/8" X 10'-0 LONG COPPER CLAD STEEL GROUND RODS (TYP.) 4.PROPOSED INSPECTION WELL (TYP.) 5.BOND H-FRAME TO GROUND RING WITH CADWELD CONNECTION (TYP. 2) 6.PROVIDE A #1/ 0 AWG SOLID BARE TINNED COPPER CONDUCTOR FROM GROUNDING LUG IN PROPOSED UTILITY METER AND BOND TO SERVICE ENTRANCE GROUND ROD AT A POINT CLOSE AS POSSIBLE. 7.GROUND SERVICE TO SERVICE GROUND ROD. 8.BOND CHAINLINK FENCE TO CLOSEST GROUND RING WITH CADWELD CONNECTIONS (TYP.). 9.BOND FENCE & GATE POSTS TO GROUND RING WITH CADWELD CONNECTIONS (TYP.). 10.BOND EVERY CORNER POST TO CLOSEST GROUND RING WITH CADWELD CONNECTIONS. GROUND TEST WELLS ARE TO BE PLACED DIAGONAL FROM FENCE. THEY ARE TO BE APPROXIMATELY 1' OFF CORNERS OF THE COMPOUND (TYP. 2) **GENERAL CONTRACTOR TO PERFORM GROUND MEG TEST PRIOR TO 48 HOUR RAIN BEFORE CLOSING TRENCHES. NED TO BE 5 OHMS OR BELOW. CONTACT CONSTRUCTION MANAGER IF HIGHER THAN 5 OHMS** 1 2 3 4 5 7 6 8 9 10 PROJECT: SITE DEVELOPMENT DESIGNER: MGD CHECKED:MGD JOB #:20KCG_NNC-0017 NO.DATE DESCRIPTION LOCATION: 0 9/12/25 FINAL THE CAPE BLVD. 613 VALLEY BROOK RD, WILMINGTON, NC 28412 CTG-NC 0010081 34.072992 , -77.901794 NEAREST ADDRESS: 1 9/04/25 DESIGN UPDATES P. MARSHALL & ASSOCIATES 2 11/19/25 DESIGN UPDATES 3 12/02/25 T-1 REVISION 4 03/11/26 REVISED LOGO 5 03/25/26 REVISED ADDRESS E-4 ELECTRICAL DETAILS SCALE: NTS GROUND ROD INSPECTION WELL 36 " 12 " 6" B E L O W F R O S T LI N E / 3 0 " M I N . COPPER CLAD STEEL GROUND ROD 5/8"x 10'-0" LONG 4" -6" LOOSE CRUSHED GRAVEL BELOW WELD. WELD SHALL REMAIN VISIBLE. 1" WIDE SLOT CUT SMOOTH FOR GROUND RING. EXTEND NOTCH 2" ABOVE CONDUCTOR CONTINUOUS GROUND RING #2 AWG BARE TINNED SOLID COPPER WIRE CADWELD ROD GROUND CONNECTION TO GROUND RING REMOVABLE COVER #2 AWG BARE TINNED SOLID COPPER WIRE TEST LOOP. CADWELD TO GROUND RING (TYP.) SCH. 40 PVC 8" DIAMETER FINISH GRADE GRADE SCALE: NTS GROUND ROD DETAIL 6" B E L O W F R O S T LI N E / 3 0 " M I N . COPPER CLAD STEEL GROUND ROD 5/8"x 10'-0" LONG CONTINUOUS GROUND RING #2 AWG BARE TINNED SOLID COPPER WIRE CADWELD EXOTHERMIC WELD CONNECTION FINISH GRADE ANGLED ROD ACCEPTABLE, ONLY IF, ROD CAN NOT BE DRIVEN VERTICAL DUE TO OBSTRUCTIONS OR BEDROCK IS ENCOUNTERED. 30° GRADE BURIED, NOT DRIVEN. REPRESENTS THE MAX. TILT ANGLE OF GROUND ROD. 1.ONE TEST WELL SHALL BE PROVIDED BETWEEN THE TOWER GROUND LOOP AND THE EQUIPMENT GROUND LOOP NOTES SCALE: NTS FINISH GRADE/SURFACE 1.PROVIDE PVC CONDUIT BELOW GRADE EXCEPT AS NOTED. 2.PROVIDE RGS CONDUIT BELOW PARKING LOTS & ROADWAYS. 3.4" TYP. SEPARATION BETWEEN CONDUIT IN SHARED TRENCH. VERIFY FINAL REQUIREMENTS WITH LOCAL UTILITY COMPANY. 4.INSTALL RED ELECTRICAL WARNING TAPE THE ENTIRE LENGTH OF THE TRENCH NOTES 30 " ( P O W E R ) 24 " ( F I B E R ) >6 " M I N . B E L O W FR O S T L I N E 4" T Y P . CO V E R 6"SAND BED UNDERGROUND CONDUIT. SEE PLAN FOR QUANTITY COMPACTED BACKFILL. (FREE OF DEBRIS) 6" UTILITY WARNING TAPE. BURIED 12" BELOW GRADE12 " UNDISTURBED SOIL UNDERGROUND CONDUIT TRENCH GRADE SCALE: NTS UNDERGROUND CONDUIT STUB-UP 12 " FINISH GRADE 36 " > 6 " M I N . BE L O W F R O S T L I N E RIGID NON-METALLIC CONDUIT COUPLING, AS APPICABLE. *CAP IF NOT IN USE TO MAKE WATER TIGHT W/ CONDUIT MALE SCREW COVER WITH TEFLON LUBRICANT RIGID NON-METALLIC CONDUIT. PROVIDE SCH. 80 PVC OR EQUAL. PVC ADAPTOR PVC SCH. 40 SIZE AS SHOWN ON LAYOUT TOP OF PAD 6" M I N . 1.PROVIDE RGS CONDUIT AND ELBOWS AT STUB-UP LOCATIONS NOTES SCALE: NTS FENCE GROUNDING CONTINUOUS GROUND RING #2 AWG BCW CADWELD CONNECTION #2 AWG BCW FENCE POST LEAD CADWELD CONNECTION