Loading...
HomeMy WebLinkAbout7750 & 7754 Market St Signed Approved Site Plans® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC TITLE, ALLOWABLE STRESSES, REV.SHEET 1 OF 15SCALE: NTS PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. XXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 10' UTILITY EASEMENT PER M.B. 47 PG 42 ACCESS AND UTILITY EASEMENT M.B. 47 PG 42 (WIDTH VARIES) >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> X MAP BOO K 6 5 , P A G E 3 5 5 AM A R Y L L I S D R I V E S4 6 ° 0 7 ' 4 9 " E 9 3 . 0 9 ' N42°41'34"E 60.12' S42°34'25"W 59.88'S42°40'58"W 58.65' N4 6 ° 1 6 ' 3 7 " W 9 3 . 2 1 ' N42°37'31"E 59.39' N4 6 ° 4 4 ' 0 2 " W 9 3 . 1 4 ' 15' SETBACK 20' SETBACK 5' S E T B A C K 5' S E T B A C K 15' SETBACK 20' SETBACK 5' S E T B A C K 5' S E T B A C K SITE 30.0 X 68.1' 5.1'4.9' 9.0' 7.0' 30 . 3 ' 17 . 4 ' 5. 0 ' 7. 0 ' 31 . 4 ' 17 . 4 ' MARKET STREET X 15 ' NT S 20 ' NT S 30 ' NT S 153.0 ' ® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC SITE PLAN SHEET 2 OF 15SCALE: 1" = 30' PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. ® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC PANEL SCHEDULE, ONE LINES SHEET 3 OF 15SCALE: NTS PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. ® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC EXTERIOR ELEVATIONS A & C SHEET 4 OF 15SCALE: NTS PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. ® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC EXTERIOR ELEVATIONS B & D SHEET 5 OF 15SCALE: NTS PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. ® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC INTERIOR FOLDOUT SHEET 6 OF 15SCALE: NTS PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. ® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC REFLECTED CEILING SHEET 7 OF 15SCALE: NTS PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. ® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC CONSTRUCTION & CABLE TRAY DETAILS SHEET 8 OF 15SCALE: NTS PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. ® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC GENERATOR SPECIFICATIONS SHEET 1 SHEET 9 OF 15SCALE: NTS PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. ® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC GENERATOR SPECIFICATIONS SHEET 2 SHEET 10 OF 15SCALE: NTS PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. ® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC GENERATOR SPECIFICATIONS SHEET 3 SHEET 11 OF 15SCALE: NTS PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. ® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC GENERATOR SPECIFICATIONS SHEET 4 SHEET 12 OF 15SCALE: NTS PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. ® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC GENERATOR SPECIFICATIONS SHEET 5 SHEET 13 OF 15SCALE: NTS PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. ® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC GENERATOR SPECIFICATIONS SHEET 6 SHEET 14 OF 15SCALE: NTS PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. ® DESIGNER: CS DATE: 3/21/2025 CLIENT: JOB TITLE: NEW HANOVER COUNTY HUT JOB LOCATION: WILMINGTON, NC MCNC GENERATOR SPECIFICATIONS SHEET 7 SHEET 15 OF 15SCALE: NTS PREPARED BY McCALL-THOMAS ENGINEERING CO., INC. N/F PID: R03600-005-270-000 GRE JV WILMINGTON LLC M.B. 47, PG. 42 N/F PID: R03600-005-020-002 MSP KB AMBERLEIGH OWNER LLC D.B. 6686, PG. 1835 M.B. 65 PG. 355 N/F PID: R03600-005-026-000 PT ALEXANDER D.B. 6775, PG. 2673 N/F PID: R03600-005-026-000 PT ALEXANDER D.B. 6775, PG. 2673 PROPOSED 11'6" x 20' x 9' CONCRETE HUT 10' UTILITY EASEMENT PER M.B. 47 PG 42 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X MARKET STREET AM A R Y L L I S D R I V E TEMPORARY CONSTRUCTION EASEMENT PER D.B. 6078 PG 1301 70'X10' SITE TRIANGLE, TYP. GRAVEL DRIVE FRONT YARD SETBACK SI D E Y A R D S E T B A C K SI D E Y A R D S E T B A C K REAR YARD SETBACK REAR YARD SETBACK FRONT YARD SETBACK FENCE, TYP. MULTI-USE PATH TOE OF DITCH TOP OF DITCH ROLLING GATE FUTURE BUILD, TYP. 12 14 13 5 16 17 18 19 10 9 8 7 6 4 3 2 15 LEGEND TREE TO BE RETAINED TREE TO BE REMOVED TREE PROTECTION LIMIT OF DISTURBANCE CRITICAL ROOT ZONE - SHOWN DIA = 1.25' FOR EVERY 1" TRUNK DIA #TREE IDENTIFICATION NUMBER GENERAL NOTES 1)All Butler Landscape Architecture drawings are based on surveys provided by owner. Contractor must verify all site conditions including site utilities prior to beginning work and notify owner of any discrepancies. 2)Contractor to have all utilities marked at least 48 hours in advance prior to digging. Any utilities shown on plan are approximate and the depth of the utility is unknown. Hand digging in areas around utilities may be required. 3)All work is to be constructed according to drawings and notes provided by Butler Landscape Architecture. Contractors are responsible for supplying materials, equipment, and labor to complete the work as per drawings and notes. 4)Changes to the proposed work, such as substitutions in materials or method of construction, is to be brought to the attention of the owner and approved before the substitution is made. 5)Contractor shall adhere to all Federal, State, and local code and ordinances including obtaining any necessary permits. Any discrepancy between the drawings and code must be brought to the attention of the owner immediately. 6)The contractor must provide a safe work site at all times and adhere to insurance requirements as set by federal, state, and local laws. 7)Contractor to provide schedule of work prior to beginning of project. The contractor is responsible for contacting the owner to review schedule, site conditions, plans and any pertinent information. Regular updates of the schedule of work to be provided to the owner. Any changes in the schedule of work must be immediately brought to the attention of the owner. 8)Site protection including protection of all existing vegetation to be provided by the contractor. Materials and debris should not be stored in protection zones at any time. Pruning of tree roots and/or branches beyond the protection zone to be brought to the attention of the owner no less than 48 hours in advance. Pruning of any roots and/or branches to be done by qualified arborist/tree professional. 9)Trash and debris clean up at the construction site is the responsibility of the contractor. At no time should the contractor dump, bury, burn, or otherwise dispose of any waste on site. Material and debris that is susceptible to being blown or otherwise dispersed must be contained as to provide a clean and tidy site at all times. 10)All waste to be removed from site and disposed of by contractor. SITE DATA OWNER: MCNC 302 E. CORNWALLIS ROAD RESEARCH TRIANGLE PARK, N.C. 27703 PROJECT ADDRESS: 7750 & 7754 OF MARKET STREET WILMINGTON, N.C. 28411 TAX PARCEL ID#: LOT #7754: 5,587 SF, LOT #7750: 5,498 SF, TOTAL SITE AREA: 11,05 SF CURRENT ZONING:B2 EXISTING USE: UNDEVELOPED PROPOSED USE: REGEN HUT EXISTING TREE TABLE NO.TREE SPECIES CALIPER REGULATION 1 PINE 14"DOCUMENTED 2 PINE 12"DOCUMENTED 3 PINE 15"DOCUMENTED 4 PINE 16"DOCUMENTED 5 PINE 32"SIGNIFICANT 6 TWIN PINE 16"DOCUMENTED 7 PINE 14"DOCUMENTED 8 PINE 16"DOCUMENTED 9 PINE 12"DOCUMENTED 10 PINE 12"DOCUMENTED 11 LIVE OAK 14"DOCUMENTED 12 MAGNOLIA 10"SIGNIFICANT 13 PINE 14"DOCUMENTED 14 LIVE OAK 12"DOCUMENTED 15 PINE 24"SIGNIFICANT 16 LIVE OAK 12"DOCUMENTED 17 LIVE OAK 12"DOCUMENTED 18 LIVE OAK 10"DOCUMENTED 19 LIVE OAK 22"SIGNIFICANT 20 LIVE OAK 12"DOCUMENTED 21 MAGNOLIA 10"SIGNIFICANT 22 LIVE OAK 25"DOCUMENTED 23 LIVE OAK 22"DOCUMENTED TOTAL EXISTING CALIPER:358" REGULATED TREES TO BE REMOVED NO.TREE SPECIES CALIPER REGULATION 3 PINE 15"DOCUMENTED 4 PINE 16"DOCUMENTED 5 PINE 32"SIGNIFICANT 6 TWIN PINE 16"DOCUMENTED 7 PINE 14"DOCUMENTED 8 PINE 16"DOCUMENTED 12 MAGNOLIA 10"SIGNIFICANT 14 LIVE OAK 12"DOCUMENTED 15 PINE 24"SIGNIFICANT 16 LIVE OAK 12"DOCUMENTED TOTAL EXIST. CAL. TO BE REMOVED:167" TREE CALCULATIONS TOTAL EXISTING CALIPER = 358" TOTAL EXISTING CALIPER TO BE REMOVED = 167" (101" OF DOCUMENTED, 67" OF SIGNIFICANT) TOTAL REMAINING CALIPER= 191" (159" OF DOCUMENTED, 32" OF SIGNIFICANT) PER UDO, SECTION 5.3.7 A) MITIGATION OF AUTHORIZED SIGNIFICANT TREES REMOVED 2 X 67" (SIGNIFICANT TREES TO BE REMOVED) = 134" PER UDO, SECTION 5.3.8. A)3 RETENTION OF EXISTING DOCUMENTED TREES 1.5 (MITIGATION INCH) X 159" (EXIST. NATIVE DOCUMENTED TREES) = 238.5" TREE NOTES PRIOR TO ANY CLEARING, GRADING, OR CONSTRUCTION ACTIVITY, TREE PROTECTION FENCING SHALL BE INSTALLED AROUND PROTECTED TREES OR GROVES OF TREES. NO CONSTRUCTION WORKERS, TOOLS, MATERIALS, OR VEHICLES SHALL BE PERMITTED WITHIN THE TREE PROTECTION AREA (TPA) AS PER UDO 5.3.6 TREE AND PLANT MATERIALS FOR LANDSCAPING. PER UDO, SECTION 5.3.8 SUBSECTION A) 3. RETENTION OF EXISTING NATIVE SPECIES UNREGULATED OR DOCUMENTED TREES A MINIMUM OF 2 INCHES DBH COUNTS FOR THE MITIGATION OF SIGNIFICANT TREES OR SPECIMEN TREES REMOVED WITH AN APPROVED VARIANCE, WITH EVERY INCH AT DBH RETAINED COUNTING FOR ONE MITIGATION INCH FOR SPECIMEN TREES AND 1.5 MITIGATION INCH FOR SIGNIFICANT TREES. Revision:Date: 7754 Market St. Wilmington, NC MCNC SCALE: DRAWN BY: DATE: MDW DRAWING NUMBER: PROJECT:MCN NO T F O R C O N S T R U C T I O N Plot plan prepared by: Utility Design Specialists on October 21, 2025 1114 Upper Reach Drive Wilmington, North Carolina 28409 Mobile: 704-562-6225 lindsay@butlerlandarch.com shep@butlerlandarch.com 11/7/2025 CHECKED BY:SB Tree Mitigation Plan L1.00 1" = 10'-0" SCALE: 0 20105 1"=10'-0" N/F PID: R03600-005-270-000 GRE JV WILMINGTON LLC M.B. 47, PG. 42 N/F PID: R03600-005-020-002 MSP KB AMBERLEIGH OWNER LLC D.B. 6686, PG. 1835 M.B. 65 PG. 355 N/F PID: R03600-005-026-000 PT ALEXANDER D.B. 6775, PG. 2673 N/F PID: R03600-005-026-000 PT ALEXANDER D.B. 6775, PG. 2673 PROPOSED 11'6" x 20' x 9' CONCRETE HUT 10' UTILITY EASEMENT PER M.B. 47 PG 42 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X MARKET STREET AM A R Y L L I S D R I V E TEMPORARY CONSTRUCTION EASEMENT PER D.B. 6078 PG 1301 70'X10' SITE TRIANGLE, TYP. GRAVEL DRIVE FRONT YARD SETBACK SI D E Y A R D S E T B A C K SI D E Y A R D S E T B A C K REAR YARD SETBACK REAR YARD SETBACK FRONT YARD SETBACK FENCE, TYP. MULTI-USE PATH TOE OF DITCH TOP OF DITCH ROLLING GATE FUTURE BUILD, TYP. 13 17 18 19 10 9 2E E E E E E E STREET YARD BUFFER PLANTING AREA = 1,025 SF STREET YARD BUFFER PLANTING AREA = 1,375 SF --EXISTING DECIDUOUS (TREE PER SURVEY) E E -- SHRUBS CALLICARPA AMERICANA AMERICAN BEAUTYBERRY 5 GAL. , 12" HT. MIN. (ABOVE GROUND) QTY: 6 -- ILEX OPACA AMERICAN HOLLY 20 GAL. QTY: 2 -- -- -- SOUTHERN WAXY SEDGE CAREX GLAUCESCENS 1-1/4" PLUGS, 12" O.C. QTY: 823 -- RIVER OAKS CHASMANTHIUM LATIFOLIUM 1 GAL. 18" O.C. QTY: 176 -- --POSSUMHAW VIBURNUM NUDUM 5 GAL. , 1' HT. MIN. (ABOVE GROUND) QTY: 3 INKBERRY ILEX GLABRA 5 GAL. , 12" HT. MIN. (ABOVE GROUND) QTY: 10 CAROLINA SILVER BELL HALESIA CAROLINA B&B, 6-8' HT. (ABOVE GROUND) QTY: 6 -- PLANT SCHEDULE TREES - CANOPY DWARF WAX MYRTLE MYRICA CERIFERA 'DON'S DWARF' 5 GAL. , 12" HT. MIN. (ABOVE GROUND) QTY: 12 -- BLACK GUM NYSSA SYLVATICA 2" CAL. QTY: 1 -- LIVE OAK QUERCUS VIRGINIANA 2" CAL. QTY: 2 DOGWOOD CORNUS FLORIDA B&B, 6-8' HT. (ABOVE GROUND) QTY: 3 -- GROUNDCOVER TREES - UNDERSTORYTREES - EXISTING --EXISTING EVERGREEN (TREE PER SURVEY) GENERAL NOTES 1)All Butler Landscape Architecture drawings are based on surveys provided by owner. Contractor must verify all site conditions including site utilities prior to beginning work and notify owner of any discrepancies. 2)Contractor to have all utilities marked at least 48 hours in advance prior to digging. Any utilities shown on plan are approximate and the depth of the utility is unknown. Hand digging in areas around utilities may be required. 3)All work is to be constructed according to drawings and notes provided by Butler Landscape Architecture. Contractors are responsible for supplying materials, equipment, and labor to complete the work as per drawings and notes. 4)Changes to the proposed work, such as substitutions in materials or method of construction, is to be brought to the attention of the owner and approved before the substitution is made. 5)Contractor shall adhere to all Federal, State, and local code and ordinances including obtaining any necessary permits. Any discrepancy between the drawings and code must be brought to the attention of the owner immediately. 6)The contractor must provide a safe work site at all times and adhere to insurance requirements as set by federal, state, and local laws. 7)Contractor to provide schedule of work prior to beginning of project. The contractor is responsible for contacting the owner to review schedule, site conditions, plans and any pertinent information. Regular updates of the schedule of work to be provided to the owner. Any changes in the schedule of work must be immediately brought to the attention of the owner. 8)Site protection including protection of all existing vegetation to be provided by the contractor. Materials and debris should not be stored in protection zones at any time. Pruning of tree roots and/or branches beyond the protection zone to be brought to the attention of the owner no less than 48 hours in advance. Pruning of any roots and/or branches to be done by qualified arborist/tree professional. 9)Trash and debris clean up at the construction site is the responsibility of the contractor. At no time should the contractor dump, bury, burn, or otherwise dispose of any waste on site. Material and debris that is susceptible to being blown or otherwise dispersed must be contained as to provide a clean and tidy site at all times. 10)All waste to be removed from site and disposed of by contractor. PLANTING AND SOIL 1)The contractor must provide at a minimum a one year guarantee on all plant material. If the owner assesses the plant to be in poor health, and the owner has provided care to promote plant health, the plant must be replaced at the cost of the contractor. 2)Contractor to provide schedule for planting of all locations and plant types. Schedule to be approved by owner before planting is begun. 3)Quantities of plants must be verified from drawing and associated plant schedule. Any discrepancies should be brought to the attention of the owner. 4)All plants to meet the requirements of the American Association of Nurserymen Standards for size, health, and typical habit of growth. Plant material may be sourced or otherwise selected by the owner but is generally the responsibility of the contractor. The owner reserves the right to reject plant material that does not meet the industry standard. 5)Large trees and specimen trees to be approved by owner. 6)All plant material must be kept in shade, protected from weather and machinery, and irrigated while on site or in a holding area. 7)Trees to be placed in planting location for approval by owner prior to planting. Planting beds to be staked or otherwise marked by contractor in order to be approved by the owner prior to planting. 8)Areas to be sodded should be left 6” below finish grade in order to receive imported topsoil. Planting beds to be left 8” below finish grade in order to receive imported planting mix. No imported topsoil or planting mix is permitted within existing woodland areas. 9)Subsoil from excavation is to be removed from site. Mixing of subsoil into planting mix not permitted. 10)Areas that do not provide conditions for plants to thrive must be brought to the attention of the owner prior to the planting of the area. 11)Areas that have been compacted due to construction must be tilled to a 24” depth in order to provide percolation. 12)Contractor must mulch all beds and tree rings to depth of 2”-3" after plants have been installed. Mulch to be double ground hardwood mulch or equivalent approved by owner. SITE DATA OWNER: MCNC 302 E. CORNWALLIS ROAD RESEARCH TRIANGLE PARK, N.C. 27703 PROJECT ADDRESS: 7750 & 7754 OF MARKET STREET WILMINGTON, N.C. 28411 TAX PARCEL ID#: LOT #7754: 5,587 SF, LOT #7750: 5,498 SF, TOTAL SITE AREA: 11,05 SF CURRENT ZONING:B2 EXISTING USE: UNDEVELOPED PROPOSED USE: REGEN HUT NOTES PRIOR TO ANY CLEARING, GRADING, OR CONSTRUCTION ACTIVITY, TREE PROTECTION FENCING SHALL BE INSTALLED AROUND PROTECTED TREES OR GROVES OF TREES. NO CONSTRUCTION WORKERS, TOOLS, MATERIALS, OR VEHICLES SHALL BE PERMITTED WITHIN THE TREE PROTECTION AREA (TPA) AS PER UDO 5.3.6 TREE AND PLANT MATERIALS FOR LANDSCAPING. PER UDO, SECTION 5.3.8 SUBSECTION A) 6. RETENTION OF EXISTING TREE COVERAGE MAY REPLACE REQUIRED STREET YARD AND TRANSITIONAL BUFFER LANDSCAPING AT A RATE OF ONE SQUARE FOOT IN BASAL AREA OF RETAINED TREES. PER UDO, SECTION 5.4.6 SUBSECTION B) TABLE 5.4.6.B - ZONING DISTRICT B-2; REQUIRED AREA = 25 SF X 96 LF (STREET YARD FOOTAGE (NOT INCLUDING DRIVEWAY WIDTH)) = 2,388 SF OF PLANTING AREA Revision:Date: 7754 Market St. Wilmington, NC MCNC SCALE: DRAWN BY: DATE: MDW DRAWING NUMBER: PROJECT:MCN NO T F O R C O N S T R U C T I O N Plot plan prepared by: Utility Design Specialists on October 21, 2025 1114 Upper Reach Drive Wilmington, North Carolina 28409 Mobile: 704-562-6225 lindsay@butlerlandarch.com shep@butlerlandarch.com 11/7/2025 CHECKED BY:SB Planting Plan L2.00SCALE: 0 20105 1"=10'-0" 1" = 10'-0"