Loading...
TRC Agenda Packet 6.16.2021TECHNICAL REVIEW COMMITTEE AGENDA June 16, 2021 New Hanover County’s Technical Review Committee (TRC) will meet Wednesday, June 16, 2021 at 2:00 p.m. at 230 Government Center Drive, Suite 110, to discuss the below items. PLEASE NOTE: This meeting will be conducted remotely via teleconference. Interested parties can contact the Planning and Land Use Department at 910-798-7165 for more information. 2:00 p.m. Item 1: Quality Chemical Labs LLC – Major Site Plan Request by Quality Chemical Labs LLC and CSD Engineering for an 8,000 square foot office/laboratory facility. The subject property is located at 3408 Enterprise Drive. It consists of 0.59 acres and is zoned PD. 2:20 p.m. Item 1: Whiskey Branch PD – Phase 1 – Preliminary Plan Request by RSC Engineering, PLLC. for a preliminary plan for Legacy Landing, consisting of 11 single-family detached units. The property is at 3204 Dorsey Lane, consists of 4.9 acres, and is zoned (CZD) R-10. Future Items: • 7038 Market Street- Porch Concepts o Major site plan for a Retail/warehouse at 7038 Market Street • 6005 and 6007 Market Street Goldenberg Office o Major site plan for a Contractor Office at 6005 and 6007 Market Street Quality Chemical Labs LLC –TRC Review Page | 1 To: Jeremy Martin, CSD Engineering jeremy@csd-engineering.com From: Ron Meredith Current Planner Date: June 11th, 2021 Subject: Quality Chemical Labs LLC – 3408 Enterprise Drive – Commercial Site Plan – TRC Review The following comments have been received for the June 16th, 2021 TRC meeting. Please note: Following the TRC meeting, a revised site plan addressing each of the below items must be resubmitted prior to receiving approval. Planning, Ron Meredith 910-798-7441 1. Please update the plan with the following general corrections: a. Please add the ITE trip generation, peak hour trips into the Site Data Table. 2. Parking: a. Please update the site data table with the new parking standards, UDO Section 5.1.2.A. Office 2.5 space /1000 sf and building and Research and Development Facility 2.5 spaces /1,000 sf. b. It appears that you are missing some parking space lines near the southeast corner of the site. c. Please add the dimensions for the parking spaces at the drive isle where the parking area shifts (adjacent to the building). 3. Landscape Plan: a. Screening: i. Please show the type of screening proposed for the dumpster. Any dumpster or trash receptacle shall be screened from the view of any public right-of-way, UDO Section 5.4.4. 4. Tree Retention: a. Please add one additional tree, UDO Section 5.3.4.C requires a minimum of 15 trees at least 2” DBH must be retained or planted for each acre or proportionate area disturbed by development. i. Please note that required landscaping for the project can be credited to meet this requirement. Quality Chemical Labs LLC –TRC Review | 2 b. Please be aware that there are new tree retention requirements with the UDO that have updated the classifications of regulated trees. Please see UDO Section 5.3.4 for more specifics. In addition, trees preserved on the site may be credited toward mitigation. c. Please be aware that a Tree Removal Permit is required prior to any land disturbance activities. Please provide the specific species (Loblolly Pine, Long Leaf Pine, etc.) of the trees to be removed or retained to determine required mitigation and whether they are native or invasive. 5. Please be sure to provide a light plan to illustrate that street lighting, all exterior lighting, and indoor lighting visible from outside shall be designed and located so that the maximum illumination measured in foot candles, at ground level, and at a lot lines, do not surpass 2.0 along other boundaries as specified in UDO Section 5.5.4. 6. Are you aware of any future sign locations? Please refer to UDO Section 5.6 for sign regulations. Fire Services, Ray Griswold 910-798-7464 1. I conducted a site visit at this location on May 20, 2021. The following observations were made. a. If the building is sprinklered then a fire hydrant shall be placed within 100 feet of the FDC. b. A Section 510 study is required per the 2018 NC Fire Code for First Responder Radio Coverage. c. Please follow the Guidelines of the 2018 NC Fire Code Appendix J - Building Information Signs. NHC Engineering (Stormwater), Galen Jamison 910-798-7142 1. Although the project appears to disturb less than one acre, the proposed site is within an existing grading permit and will therefore be required to obtain an erosion control permit. Please submit for permit as the design is completed. 2. A stormwater system authority to construct is required for this project. Please submit for permit as the design is completed. 3. Will the adjacent parcels stormwater drainage be directed to the proposed pond? 4. 4. An agreement for operations and maintenance of the stormwater pond will be required between the 2 parcels. Cape Fear Public Utility Authority, Bernice Johnson 910-332-6620 1. CFPUA plan review required. 2. CFPUA water and sewer available. 3. CFPUA Meter Sizing Form will be required. NCDOT, Patrick Wurzel, 910-398-9100 1. These preliminary comments and are based on the plans as submitted for the proposed site and are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. 2. A NCDOT Driveway Permit is required. Submit a plan in accordance with pages 14 and 15 of the Policy on Street and Driveway Access to North Carolina Highways to include access locations within 500’ of the proposed access on both sides of the State road. Submit to the local NCDOT District Engineer’s Office. 3. A NCDOT Encroachment Agreement is required for any utility connections or installation within NCDOT right-of-way. 4. NCDOT Driveway Permits are now submitted through the NCDOT Driveway website. https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx Quality Chemical Labs LLC –TRC Review | 3 Environmental Health, Marie Hemmen 910-798-6664 1. OSWP Comments: No review required. This property will be connecting to CFPUA water and sewer. There are no wells or septic systems in this area that OSWP section has record of. WMPO, Scott A. James, 910-341-5130 1. 8k sf of general office does not generate sufficient daily or peak hour trips to require a TIA 2. No identified nearby roadway improvements Planning (Addressing), John Townsend 910-798-7443 1. Enterprise Dr - Contact Planning if there is there are any suites/units planned Comments not received at this time from: NCDEQ, Chad Coburn New Hanover Soil & Water, Dru Harrison NCDEMLR, Dan Sams DCM, Tanya Pietila USACE, Rachel Capito New Hanover County Schools, Laura Severt Legacy Landing - TRC Review Page | 1 To: Sonya Edens – RSC Engineering, PLLC (sonya@rscengineering.com). From: Ron Meredith Current Planner Date: June 11, 2021 Subject: Legacy Landing (CZD) R-10 – Preliminary Plan TRC Review The following comments have been received for the June 16, 2021 TRC meeting. Please note: Following the TRC meeting, a revised preliminary plan addressing each of the below items must be resubmitted prior to receiving preliminary plan approval. Planning, Ron Meredith 910-798-7441 1. Please update the plan with the following general corrections: a. Please show the 10x70 sight angles. b. Please list in the site data table the tax map, block, and parcel numbers. 2. Sidewalk: a. Please be aware that sidewalks are required on one side of the right-of-way in the R-10 zoning districts, UDO Section 6.3.3J.1.C. The TRC may exempt sidewalk installation in specific cases upon finding that sidewalks are unnecessary for the protection of the public safety or welfare due to conditions peculiar to the site. b. Are any traffic calming devices proposed? If so, TRC approval is required, UDO Section 6.2.2.A.7.m. 3. Tree Retention: a. Please be aware that a Tree Removal Permit is required prior to any land disturbance activities. b. The tree retention standards have recently been updated. Please provide the specific species (Loblolly Pine, Long Leaf Pine, etc.) of all regulated trees to be removed or credited for mitigation. In addition to the significant trees, please list all regulated trees to be removed. Legacy Landing - TRC Review Page | 2 4. Easements: a. UDO Section 6.2.2, please label Storm Sewer, Sanitary Sewer, and Water Main Utility Easements. 5. Mailbox Kiosks: a. Please show parking for the mail kiosk, a paved area is required to allow vehicles to pull off, park, and re-enter the roadway safely, UDO Section 6.2.2A.15. 6. Roadway Design: a. Please verify that the tangent lengths meet the code requirements specified by the County’s private road standards. 7. Property Owners’ Association (POA): a. Please be aware that the Property owners’ association is responsible for continuing upkeep and maintenance of all private infrastructure facilities and common areas within the respective subdivision. 8. Is there any intention of installing signage? If so, please show the location and note any proposed sign is subject to UDO Section 5.6. 9. Please provide all NCDOT approvals upon receipt. 10. Please consider extending the open space around the pump station. 11. Please consider providing screening for the pumpstation. Fire Services, Raymond Griswold (910-798-7448) 1. No further comments NHC Engineering, Galen Jamison (910-798-7072) 1. A land disturbing permit is required for this project. Please submit for permit as the design is completed 2. The revised submission for the Stormwater System Authorization to Construct application has been discussed with the applicant. Please resubmit for the ATC upon completion of the design. NHC Environmental Health, Marie Hemmen (910-798-6664) 1. OSWP Comments: No review required. This property will be connecting to CFPUA water and sewer. There are no wells or septic system setback issues in this area that OSWP section is aware of because it appears that all adjacent properties are connected to CFPUA water and sewer. Cape Fear Public Utility Authority, Bernice Johnson (910-332-6620) 1. CFPUA water and sewer available. 2. Water and sewer mainline extensions will be required. 3. Pump Station will be required. 4. Project to provide easements access for gravity sewer to adjoining parcels 5. At this time capacity is available. 6. Capacity is also dependent on the analysis of the pipe collection system (gravity and force mains). 7. Capacity is issued to projects on a first come, first serve basis, when capacity is available, the plans meet Authority requirements, and the NC DWQ FTA/FTSE forms are signed by the Authority. Legacy Landing - TRC Review Page | 3 NCDOT, Joseph Wurzel (910-398-9100) 1. These preliminary comments and are based on the plans as submitted for the proposed site and are subject to further review upon receipt of any additional information. Subsequently, additional comments and/or requirements may be necessary for this site. 2. A NCDOT Driveway Permit is required. Submit a plan in accordance with pages 14 and 15 of the Policy on Street and Driveway Access to North Carolina Highways to include access locations within 500’ of the proposed access on both sides of the State road. Submit to the local NCDOT District Engineer’s Office. 3. If the roads want to be petitioned to NCDOT, plan approval is required prior to construction 4. If driveway radius encroaches on the frontage of an adjacent property, a radius encroachment letter is required. 5. A NCDOT Encroachment Agreement is required for any utility connections or installation within NCDOT right-of-way. 6. NCDOT Driveway Permits are now submitted through the NCDOT Driveway website. https://connect.ncdot.gov/municipalities/Utilities/Pages/help.aspx Planning (Addressing), John Townsend (910-798-7443) 1. Legacy Landing – contact Planning for address assignment when ready to move forward after TRC approval Comments not received at this time from: NCDEMLR, Linda Lewis, 910-796-7343 USACE, Rachel Capito, 910-251-4000 WMPO Amy Kimes Emergency Services & E911, Steve Still NCDEQ, Chad Coburn New Hanover Soil & Water, Dru Harrison DCM, Courtney Spears New Hanover County Schools, Mark Clawson