Loading...
2022-015 Bluetail Industrial Park_1-25-23 - Planning Set2EX. BLOCK BLDG. EX. METAL BLDG. BL U E C L A Y R O A D ( R / W V A R I E S ) FF 49.5' FF 50.4' X X X XXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X MA G N E T I C MB 5 8 , P G 3 2 9 EX. SHED TO BE REMOVED N/F INMAN DAN E MARIE P R03316-004-001-001 DB 1353, PG 939 ZONE: AC USE: COMMERCIAL N/ F SK Y E P R O P E R T I E S H O L D I N G I N C R0 3 3 1 6 - 0 0 4 - 0 0 6 - 0 0 0 DB 6 5 4 0 , P G 2 0 4 1 ZO N E : A C US E : C O M M E R C I A L N/F NEW HANOVER COUNTY AIRPORT AUTHORITY R03316-004-004-000 DB 6253, PG 2792 ZONE: AC USE: VACANT N/F TF HOLDINGS LIMITED PTNP R03316-004-003-000 DB 1783, PG 1251 ZONE: AC USE: VACANT PU B L I C R / W V A R I E S ) 24 4 ' 8,900 SF TOTAL APPROX. LOCATION EX. WELL AP P R O X . L O C A T I O N E X . 1 4 " S S F M EX.POWER POLE TO BE RELOCATED (CONTRACTOR TO COORDINATE WITH POWER COMPANY FOR RELOCATION) PROP. LOT-A “$& PROP. LOT-B “$& BAY DOORS N/F AIC CONDOMINIUM ASSN INC R03300-005-021-000 DB 4260, PG 0467 ZONE: AC USE: COMMERCIAL N/F AIC CONDOMINIUM ASSN INC R03300-006-002-000 DB 2380, PG 0860 ZONE: AC USE: COMMERCIAL N/F TRASK ALEX M JR HRS R03300-005-005-001 DB 9993, PG 1508 ZONE: AC USE: VACANT APPROX. LOCATION EX. DI EX. GRAVEL/SOIL AREAS TO BE RESURFACED WITH GRAVEL EX. GRAVEL/SOIL AREAS TO BE REMOVED EX. GRAVEL/SOIL AREAS TO BE REMOVED EX. OVERHEAD CRANE RAILS (LOCATION IS APPROX.) PROP. LOTLINE PR O P . L O T L I N E C-0 1 EX I S T I N G C O N D I T I O N S A N D DE M O L I T I O N P L A N 1" = 30' PROPERTY LINE ADJOINERS SILT FENCE LIMITS OF DISTURBANCE PROP. DEMO AREAS LEGEND REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): 2022-015 CLIENT INFORMATION: Bluetail Properties, LLC Dustin Braudway 366 Shorepoint Dr. Wilmington, NC 28411 910-233-9629 OF 6 JAE CDC CDC 24x36 1/25/2023 BL U E T A I L I N D U S T R I A L PA R K SITE AIRPORT BLU E C L A Y R D NORTH KERR AVE NORTH KERR AVE O L D W R I G H T S B O R O R D AC O R N B R A N C H R D S R 1 3 1 9 SR 1 3 7 0 PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N SITE DATA PARCEL ID:R03316-004-002-000 CURRENT ZONING:AC PROJECT ADDRESS:2701 BLUE CLAY RD. WILMINGTON, NC 28405 CURRENT OWNERS:BLUETAIL PROPERTIES, LLC 366 SHOREPOINT DR. WILMINGTON, NC 28411 TOTAL ACREAGE IN PROJECT BOUNDARY 6) “DF EXISTING ONSITE IMPERVIOUS AREAS: GRAVEL (DRIVES, PARKING & STORAGE):33,235 S.F. BUILDINGS: 9,925 S.F. ASPHALT: 1,440 S.F. TOTAL:44,600 S.F. EXISTING ONSITE IMPERVIOUS AREAS TO BE REMOVED: GRAVEL (DRIVES, PARKING & STORAGE):12,428 S.F. BUILDINGS: 145 S.F. ASPHALT: 1,440 S.F. TOTAL:14,013 S.F. EXISTING ONSITE IMPERVIOUS AREA TO REMAIN: 30,587 S.F. SOILS TYPE:No (Norfolk fine sandy loam) 83.4% Wo(Woodington find sandy loam)16.6% DEVELOPMENT NOTES: 1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY LAND DEVELOPMENT CODE. 2.PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS. 3.EXISTING SURVEYING PERFORMED BY F.W. JONES SURVEYING COMPANY. 4.SITE IS LOCATED IN ZONE "X" PER FRIS ON FIRM MAP NUMBER 3720312900K, DATED 8/28/2018. 5.NO WETLANDS OR SURFACE WATERS EXIST ON SITE. 6.NO REGULATED TREE EXIST ON SITE. 60'30'15'30'0' Scale: 1"=30' EX. BLOCK BLDG. EX. METAL BLDG. BL U E C L A Y R O A D ( R / W V A R I E S ) FF 49.5' FF 50.4' 18 ' 9' 11 GRAVEL PARKING AREA MA G N E T I C MB 5 8 , P G 3 2 9 5' 15' N/F INMAN DAN E MARIE P R03316-004-001-001 DB 1353, PG 939 ZONE: AC USE: COMMERCIAL N/ F SK Y E P R O P E R T I E S H O L D I N G I N C R0 3 3 1 6 - 0 0 4 - 0 0 6 - 0 0 0 DB 6 5 4 0 , P G 2 0 4 1 ZO N E : A C US E : C O M M E R C I A L N/F NEW HANOVER COUNTY AIRPORT AUTHORITY R03316-004-004-000 DB 6253, PG 2792 ZONE: AC USE: VACANT N/F TF HOLDINGS LIMITED PTNP R03316-004-003-000 DB 1783, PG 1251 ZONE: AC USE: VACANT PU B L I C R / W V A R I E S ) 8,900 SF TOTAL DI#1 RIM: 47.8 INV: 44.9 DI#2 RIM: 47.8 INV: 44.5 15" RCP 18 " R C P APPROX. LOCATION EX. WELL PROPOSED PRIVATE DUPLEX SS LIFT STATION (SEE LIFT STATION PACKAGE) DI#3 RIM: 47.8 INV: 45.0 5' C O N C . S I D E W A L K AP P R O X . L O C A T I O N E X . 1 4 " S S F M 2" PRIVATE PVC S S F M . 16 ' TIE TO EX. SS FM W/ (1) 2" X 14" T.S.&V.) (1) CONC. VAULT (SEE DETAIL) PROP. LOT-A “$& PROP. LOT-B “$& PRIVATE ACCESS, DRAINAGE & UTILITY EASEMENT (WIDTH VARIES) 10' D.E. 48.6 48.3 47.9 48.35 48.3 MATCH EX. ASPHALT “ 48.5 49.048.3 48.9 TAPER CURB TO FLAT 49.0 49.0 49.0 49 49 50.0 49.5 50.4 49.5 49.25 48.8 49.3 48.7 49.0 49.3 50.3 UP ADA PARKING SIGN BAY DOORS AIC CONDOMINIUM ASSN INC N/F TRASK ALEX M JR HRS R03300-005-005-001 DB 9993, PG 1508 ZONE: AC USE: VACANT APPROX. LOCATION EX. DI DI#5 RIM: 48.5 INV: 45.0 DUMPSTER PAD & ENCLOSURE 48.8 49.5 150' 60 'BAY DOORS BAY DOORS SHOWROOMSHOP 16' UP 48.9 48.9 48.9 48.8 48.5 48.3 48.9 23 ' 48.9 TAPER CURB TO FLAT (TYP @ BUILDING) 49.0 48 48 48.9 51 . 5 ' 18 ' 1 5 " R C P 49.25 48.35 DI#4 RIM: 47.65 INV: 45.25 48.5 48.25 48.5 49.25 49.5 15" RCP 48.4 48.5 20 ' P R I V A T E D . E . 48.4 47 49 49 45 4546 22 ' 46 4 5' X 5' CONC. PAD ADA PARKING SIGN OUTLET STRUCTURE (SEE DETAIL) SDMH#1 RIM: 46.75 INV: 44.65 47 48.2 48.8 48.9 48.5 EX. OVERHEAD CRANE RAILS (LOCATION IS APPROX.) PROP. LOTLINE PR O P . L O T L I N E 7' 23' C-1 2 1" = 30' OVERALL PROJECT SITE DATA PARCEL ID:R03316-004-002-000 CURRENT ZONING:AC PROJECT ADDRESS:2701 BLUE CLAY RD. WILMINGTON, NC 28405 CURRENT OWNERS:BLUETAIL PROPERTIES, LLC 366 SHOREPOINT DR. WILMINGTON, NC 28411 TOTAL ACREAGE IN PROJECT BOUNDARY 6) “DF TOTAL ON-SITE IMPERVIOUS AREAS: LOT-A 35,500 S.F. LOT-B 35,000 S.F. TOTAL 70,500 S.F. (67.7%) ESTIMATED TRIP GENERATION (Per Trip Generation Manual): 17,900 SF LIGHT INDUSTRIAL (ITE CODE 110) AM PEAK: 13 PM PEAK: 12 DAILY: 87 EXISTING SEWER AND WATER DEMAND: 0 GPD PROPOSED SEWER AND WATER DEMAND: 625 GPD LOT-A SITE DATA: PROPOSED USE:ARTISAN MANUFACTURING PROPOSED LOT SIZE:6) “DF BUILDING SIZE:8,900 S.F. G.F.A. BUILDING HEIGHT:“  6725< CALCULATION FOR BUILDING COVERAGE: PROPOSED COVERAGE 6)·6)  BUILDING SETBACKS: FRONT:REQUIRED= 50'EXISTING= 3'PROPOSED= 77' SIDE:REQUIRED= 0'EXISTING=10'L/118'R PROPOSED= 20'L/64'R REAR:REQUIRED= 0'EXISTING=53'PROPOSED= 163' PROPOSED IMPERVIOUS AREAS: GRAVEL PARKING AREA 6,095 S.F. CONCRETE (SIDEWALK, C&G, ETC.) 1,090 S.F. FUTURE 11,235 S.F. TOTAL 18,420 S.F (30.65%) TOTAL ON-SITE IMPERVIOUS AREA: PROPOSED:18,420 S.F. EXISTING TO REMAIN:17,080 S.F. TOTAL:35,500 S.F. (59.1%) PARKING REQUIRED ARTISAN MANUFACTURING: (1.5 Spaces per 1,000 SF GFA) PARKING REQUIRED:13 SPACES (1 ADA) PARKING PROVIDED:13 SPACES (1 ADA) PARKING LOT INTERIOR LANDSCAPING REQUIRED 13,395 S.F. * 8% 1,072 S.F. PROVIDED 1,260 S.F. FOUNDATION PLANTINGS: NORTH FACADE: 102 LF X 12' FACADE X 12% REQUIRED:147 S.F. PROVIDED:185 S.F. WEST FACADE: 96 LF X 16' FACADE X 12% REQUIRED:184 S.F. PROVIDED:185 S.F. STREETYARD: (MULTIPLIER: 18' MAX: 27' MIN: 9') REQUIRED: 244' - 30' = 214' X 18'= 3,852 S.F. PROVIDED:4,425 S.F. LOT-B SITE DATA: PROPOSED USE:ARTISAN MANUFACTURING PROPOSED LOT SIZE:6) “DF BUILDING SIZE:9,000 S.F. G.F.A. TOTAL BUILDING HEIGHT:“  6725< CALCULATION FOR BUILDING COVERAGE: PROPOSED COVERAGE 6)·6)  BUILDING SETBACKS: FRONT:REQUIRED= 50'PROPOSED= 79' SIDE:REQUIRED= 0'PROPOSED= 83'L/54'R REAR:REQUIRED= 0'PROPOSED= 12' PROPOSED IMPERVIOUS AREAS: BUILDINGS ROOFS 9,000 S.F. GRAVEL PARKING AREA 8,890 S.F. CONCRETE (SIDEWALK, C&G, ETC.) 1,305 S.F. FUTURE 2,298 S.F. TOTAL 21,493 S.F (48.8%) TOTAL ON-SITE IMPERVIOUS AREA: PROPOSED:21,493 S.F. EXISTING TO REMAIN:13,507 S.F. TOTAL:35,000 S.F. (79.5%) PARKING REQUIRED ARTISAN MANUFACTURING: (1.5 Spaces per 1,000 SF GFA) PARKING REQUIRED:14 SPACES (1 ADA) PARKING PROVIDED:15 SPACES (1 ADA) PARKING LOT INTERIOR LANDSCAPING REQUIRED 22,397 S.F. * 8% 1,792 S.F. PROVIDED 1,900 S.F. FOUNDATION PLANTINGS: SOUTH FACADE: 150 LF X 16' FACADE X 12% REQUIRED:288 S.F. PROVIDED:305 S.F. REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): 2022-015 CLIENT INFORMATION: Bluetail Properties, LLC Dustin Braudway 366 Shorepoint Dr. Wilmington, NC 28411 910-233-9629 OF 6 JAE CDC CDC 24x36 1/25/2023 BL U E T A I L I N D U S T R I A L PA R K SITE AIRPORT BLU E C L A Y R D NORTH KERR AVE NORTH KERR AVE O L D W R I G H T S B O R O R D AC O R N B R A N C H R D S R 1 3 1 9 SR 1 3 7 0 PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N PROPERTY LINE ADJOINERS RUNOFF DIRECTION PROPOSED SSFM PROPOSED SANITARY SEWER LINE ENERGY DISSIPATER SPOT ELEVATION GRAVEL PARKING AREA PARKING LOT LANDSCAPING STREETYARD LANDSCAPING FOUNDATION PLANTINGS LEGEND 25.5 DEVELOPMENT NOTES: 1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH NEW HANOVER COUNTY LAND DEVELOPMENT CODE. 2. PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS. 3. RUNOFF FROM ALL IMPERVIOUS SURFACES INCLUDING ROOF DRAINS TO BE ROUTED TO PROPOSED WET DETENTION BASIN. 1. EXISTING SANITARY SEWER SERVICE IS CURRENTLY AVAILABLE TO THE SITE FROM CAPE FEAR PUBLIC UTILITY AUTHORITY PUBLIC SANITARY SEWER FORCE MAINS. 2. WATER WILL BE PROVIDED VIA EXISTING ON-SITE PRIVATE WELL. 3. ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS & TELEPHONE SHALL BE INSTALLED UNDERGROUND. 4. ALL SEWER UTILITIES TO BE INSTALLED PER CFPUA TECHNICAL SPECIFICATIONS & STANDARDS. 5. THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIES DURING CONSTRUCTION. CALL NC811 AT 811 OR 1-800-632-4949. CONTRACTOR IS RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ANY UTILITIES, CURB & GUTTER, PAVEMENT, ETC. THAT MAY BE BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIRED TO AT LEAST THE QUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM. 6. THE PROCESS FOR TELEPHONE CABLE PLACEMENT: * FINAL GRADE WILL NEED TO BE ESTABLISHED. * POWER WILL PLACE THEIR CABLE FIRST - APPROXIMATELY 3' DEEP. * TELEPHONE & CABLE TV WILL THEN PLACE THEIR CABLE AT APPROXIMATELY 2' DEEP. 7. SOLID WASTE DISPOSAL BY PRIVATE DUMPSTER SERVICE. 8. ALL WATER AND SANITARY SEWER LINES TO BE BURIED AT 36" MIN. DEPTH. 9. 3' SEPARATION REQUIRED BETWEEN ALL JOINTS, FITTINGS AND SERVICE SADDLES. 10. NO FORMAL SITE LIGHTING IS PROPOSED AT THIS TIME. UTILITY NOTES: FIRE & SAFETY NOTES: 1. PROPOSED BUILDING WILL NOT BE SPRINKLED. 2. CONTRACTOR SHALL MAINTAIN AN ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES AT ALL TIMES DURING CONSTRUCTION. 3. BUILDING INFORMATION SIGNS MUST BE PROVIDED IN ACCORDANCE WITH THE "2018 NC FIRE CODE APPENDIX J" REQUIREMENTS. 4. CONTRACTOR SHALL SUBMIT A RADIO SIGNAL STRENGTH STUDY FOR ALL COMMERCIAL BUILDINGS THAT DEMONSTRATES THAT EXISTING EMERGENCY RESPONDER RADIO SIGNAL LEVELS MEET THE REQUIREMENTS OF SECTION 510 OF THE 2018 NC FIRE CODE. 60'30'15'30'0' Scale: 1"=30' SI T E , G R A D I N G , D R A I N A G E , ST O R M W A T E R & U T I L I T I E S P L A N C-3 4 DE T A I L S NTS REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: VICINITY MAP (NOT TO SCALE): 2022-015 CLIENT INFORMATION: Bluetail Properties, LLC Dustin Braudway 366 Shorepoint Dr. Wilmington, NC 28411 910-233-9629 OF 6 JAE CDC CDC 24x36 1/25/2023 BL U E T A I L I N D U S T R I A L PA R K SITE AIRPORT BLU E C L A Y R D NORTH KERR AVE NORTH KERR AVE O L D W R I G H T S B O R O R D AC O R N B R A N C H R D S R 1 3 1 9 SR 1 3 7 0 PRE L I M I N A R Y DRA W I N G D O N O T U S E FOR C O N S T R U C T I O N NTS 2" S9.5B 8" ABC DRIVEWAY APRON PAVEMENT SECTION COMPACTED SUBGRADE COIR MESH OR SIMILAR, STAPLED OR TRENCHED INTO BOTTOM OR SIDE. STEEL SUPPORT POST 24" INTO BOTTOM OR SIDE STAKE TO SUPPORT WIRESUPPORT ROPE TO WIRE TO PREVENT SAGGING CROSS SECTION NTS POROUS BAFFLE DETAIL FLOW POROUS BAFFLES 25% SA 25% SA 25% SA 25% SA PLAN PLAN 1" 6" 5 3/4" MANHOLE DIAMETERSHALL BE 1'-0"LARGER THAN THE FORM FLOW CHANNEL 3'-3" MIN. 3'-1 3/4" MIN. CONC.MH BLOCKS PRECAST MH RINGS SECTION STORM DRAIN MANHOLE DETAIL BLOCK CONC. M.H. NTS 8"LARGEST PIPE 8" 1. CONTRACTOR MAY USE BRICK WITH MAX. CORBEL 1" PER COURSE 2. CONTRACTOR MAY USE ECCENTRIC M.H. UNIT NOTE MIN WEIGHTS:FRAME: 208 LBS.COVER: 120 LBS. 3/4" CEMENT MORTAR SEAL STD. M.H. RING & COVER 1'-0" OCM.H. STEPS @ 1'-0" 1'-0" DOT APPROVED PRECAST 4" RISER RING PRECAST M.H. UNITS WITH CAST IN PLACE STEPS @ 12" OC SIDEWALK SECTION A-A 4' min SECTION B-B A A B B “1.0-8.3% (30"MAX RISE) 10% MAX (X=36"MIN) 8.3% MAX (X<36") (FOR ALTERATIONS RAMP CURB AND GUTTER WARNING DOMES 2' MIN 1.6-2.4" (TYP) RAMP WIDTH 0.2" Flare WARNING DOMES 4' FLARE 2. X LAN D I N G 1.6-2.4" (TYP) TRUNCATED DOMES BASE DIAMETER 0.9-1.4" TOP DIAMETER 50-60% OF BASE (TYP) LANDING NTS WHEEL CHAIR RAMP DETAIL SITE WORK NOTES: 1.THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS BOTH ON AND ADJACENT TO THE SITE. 2.CLEARING: CONTRACTOR SHALL REMOVE ALL TREES AND VEGETATION WITHIN LIMITS OF CONSTRUCTION UNLESS OTHERWISE DESIGNATED TO REMAIN. 3.GRUBBING AND STRIPPING: CONTRACTOR SHALL RAKE AND REMOVE ROOTS, STUMPS, VEGETATION, DEBRIS, EXISTING STRUCTURES ABOVE AND BELOW GRADE, ORGANIC MATERIAL OR ANY OTHER UNSUITABLE MATERIAL WITHIN LIMITS OF CONSTRUCTION. 4.MUCKING: CONTRACTOR SHALL COORDINATE WITH OWNER AND THEIR GEOTECHNICAL REPRESENTATIVE TO COORDINATE REMOVAL OF ANY SOFT AREAS. 5.DISPOSAL: CLEARED, GRUBBED, STRIPPED OR OTHER WASTE MATERIAL SHALL BE REMOVED FROM SITE AND DISPOSED OF IN A PROPERLY PERMITTED FACILITY. 6.FILL AND COMPACTION SHOULD COMPLY WITH GEOTECHNICAL RECOMMENDATIONS. 7.THE CONTRACTOR SHALL NOTE THAT THE GRADING PLAN MAY NOT REPRESENT A BALANCED EARTHWORK CONDITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CUT AND FILL QUANTITIES AND COMPLETE INSTALLATION TO SPECIFIED GRADES. 8.THE CONTRACTOR SHALL FURNISH SUITABLE BORROW MATERIAL FROM AN OFF-SITE PROPERLY PERMITTED FACILITY AS REQUIRED. 9.INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXACT ELEVATIONS AND LOCATIONS OF ALL EXISTING UTILITIES AT ALL CROSSINGS PRIOR TO COMMENCING TRENCH EXCAVATION. IF ACTUAL CLEARANCES ARE LESS THAN INDICATED ON PLAN, THE CONTRACTOR SHALL CONTACT THE DESIGN ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. ANY CONDITION DISCOVERED OR EXISTING THAT WOULD NECESSITATE A MODIFICATION OF THESE PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. 10.NO CONSTRUCTION IS TO BEGIN BEFORE LOCATION OF EXISTING UTILITIES HAS BEEN DETERMINED. CALL "NC ONE-CALL" AT LEAST 48 HOURS BEFORE COMMENCING CONSTRUCTION. 11.THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES DURING CONSTRUCTION. BEFORE COMMENCING ANY EXCAVATIONS IN OR ALONG ROADWAYS OR RIGHT-OF-WAYS, PUBLIC AREAS OR IN PRIVATE EASEMENTS, THE CONTRACTOR SHALL NOTIFY ALL APPROPRIATE PERSONNEL OF THEIR INTENT TO EXCAVATE, IN WRITING, NOT LESS THAN 10 DAYS PRIOR TO EXCAVATING. 12.THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE DISCONNECTION/ RECONNECTION AND/OR THE RELOCATION OF ALL EXISTING UTILITIES WITH APPROPRIATE PERSONNEL. 13.CONTRACTOR SHALL ADJUST ALL MANHOLES, VALVE & CURB BOXES TO FINAL GRADE UPON COMPLETION OF ALL CONSTRUCTION. ANY BOXES DAMAGED OR OTHERWISE DISTURBED BY THE CONTRACTOR SHALL BE REPAIRED AT THE EXPENSE OF THE CONTRACTOR. 14.THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AT THE SITE. FURTHERMORE THE CONTRACTOR SHALL REPORT ALL DISCREPANCIES OR QUESTIONS TO THE ENGINEER PRIOR TO INSTALLATION. 15.THE CONTRACTOR SHALL PROVIDE ANY AND ALL LAYOUT REQUIRED TO CONSTRUCT HIS WORK UNLESS OTHERWISE DIRECTED BY OWNER. 16.ALL SERVICE CONNECTIONS SHALL BE INSTALLED TO MEET ALL LOCAL, STATE, AND CFPUA CODES. METERS, TAPS, MATERIALS, WORKMANSHIP AND ALL FEES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL COMPLY WITH ALL REQUIREMENTS. 17.ALL BACKFILL FROM UTILITY INSTALLATION MUST BE COMPACTED OR AMENDED TO PROVIDE TRAFFIC BEARING CAPACITY. GEOTECHNICAL ENGINEER TO BE CONSULTED AT CONTRACTORS COST AS NECESSARY. 18.ALL AREAS SHALL BE GRADED FOR POSITIVE DRAINAGE. CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO INSTALLATION. ALL AREAS SHALL BE SLOPED TO DRAIN AWAY FROM BUILDINGS AT ALL TIMES. 19.CONCRETE FOR WALKS, CURBS AND DRIVES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI @ 28 DAYS - AIR ENTRAINED. 20.FIELD TESTING SHALL BE DONE BY AN INDEPENDENT TESTING LABORATORY PAID FOR BY THE OWNER. FURTHER TESTING REQUIRED DUE TO A FAILED TEST WILL BE PAID FOR BY THE CONTRACTOR. 21.ALL SIDEWALKS SHALL BE FREE OF CRACKS, BREAKS, OR ANY OTHER DEFECT PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. PROPOSED DRIVEWAY GRADE 2% MIN SLOPE 6' MIN FROM EX. EOP TYPICAL DRIVEWAY GRADING SECTION NTS (;52$'“6/23( DROP INLET DETAIL 3000 PSI CONC. NTS BRICK MASONRY FLOW 6" CONC. COLLAR 6" DROP INLET TO HAVE SAND LEAVE OPENING AS SHOWNTRAP, DROP FOOTING 12" & ELEV. VARIES ASPHALT PAVEMENT SECTION NOTE: 8" 2'-0"8"8" 1'-0" VA R I E S 4" CONC. COLLAR SEE PLAN FOR PIPEORIENTATION NOTE: USE DEWEY BROS. FOR YARD INLETSBASINS AND CH-BN-47CH-BN 3A FOR CATCH PLAN CASTING WHEEL STOP DETAIL NTS 1. CONTRACTOR SHALL INSTALL PER CITY OF WILMINGTON TECHNICAL STANDARD PER SD 15-13 NOTE: WIDTH x LENGTH x HEIGHT 1/2"1/2"6'-11" FRONT VIEW ‘+2/(6 1/2" END VIEW 4" 4.5" 1/2"8" 9" x 7'-0" x 4" 4000 PSI @ 4 - #4 REBAR 28 DAYS CONCRETE: REINFORCING: PLAN VIEW 12"7'12" 2. CONTRACTOR SHALL INSTALL WHEEL STOP 2.5' FROM SIDEWALK. 1-1/2"R(TYP) WHITE SYMBOL ON BLUE BACKGROUND LEGEND AND BORDER - GREENBACKGROUND - WHITE 12" 3/8"(TYP) LEGEND AND BORDER - GREEN BACKGROUND - WHITE 12" COLORS 1-1/2"R(TYP) LEGEND AND BORDER - GREENBACKGROUND - WHITE 18" 3/8"(TYP) TO READ "VAN ACCESSIBLE". BOLT TO WD. POST WITH 3/8" CANDIUM PLATED NUTS, BOLTS & WASHERS 9" x 1'-6" x .080 STD ALUM. SIGN NUTS, BOLTS & WASHERS. 9" x 1'-0" x .080 STD ALUM. SIGN TO READ "MAXIMUM PENALTY $250, GS 20-37.6". BOLT TO WD. POST WITH 3/8" CANDIUM PLATED PRESSURE TREATED 4"x4" POST. FINISHED GRADE HANDICAPPED PARKING SIGN WITH IDENTIFICATION SYMBOL. 1'-6" x 1'-0" x .080 STD. ALUM. TO READ "RESERVED PARKING" BOLT TO WD. POST W/ 3/8" CANDIUM PLATED NUTS, BOLTS & WASHERS. TYPICAL HANDICAPPED SIGN DETAIL NTS R7-8a Sign (no arrows) R7-8d Sign R7-8P Sign 2 1 6 1 3 1 TOP OF SHELF 45.2 BOTTOM OF SHELF 44.2 CLEAN OUT 39.2 CLEAN OUT 36.9 NTS 44.244.2 CLASS "B" RIP RAP 1' MIN. TUCK (TYP.) NON-WOVEN GEOTEXTILE FABRIC NORMAL POOL EL. 44.73 1 *POND SLOPE TO BE SEEDED IN ACCORDANCE TO SEEDING SPECIFICATIONS *6:1 VEGETATED SHELF TO BE PLANTED WITH WETLAND SPECIES I.E. PICKEREL WEED, DUCK POTATO, SWAMP ROSE, BLUE FLAG, & CARDINAL FLOWER. (OR ENGINEER APPROVED ALTERNATIVE) *VEGETATED SHELF SHALL BE PLANTED WITH PLUGS OR POTS AT 24" O.C. IN A CHECKERBOARD PATTERN. *VEGETATED SHELF PLANTING SHALL NOT BE PLANTED WITHIN 10' OF THE OUTLET STRUCTURES. *A PUMP WILL BE PROVIDED TO DRAIN THE BASIN FOR MAINTENANCE AND EMERGENCIES * ANY PORTION OF WET DETENTION BASIN USED FOR S&EC DURING CONSTRUCTION MUST BE CLEANED OUT AND RETURNED TO DESIGN STATE BEFORE USE AS A WET DETENTION BASIN. EL. 48.0 TOP OF BANK DETENTION POND & FOREBAY SECTION 5' EMBANKMENT NORMAL POOL EL. 44.7 MAIN POOL 2 1 1 BOTTOM 37.9 FLOOD POOL EL 46.25 MI N . 6" FOREBAY 2.5 1 BOTTOM EL. 40.22.5 FOREBAY BERM BEYOND EL. 48.0 TOP OF BANK 3'-0" SECTION A - A 6"6" BOTTOM 4" PVC PIPE W/1.5" ORIFICE 3'-0" PLAN INV. 44.7 INV. 43.7 GALV. BAR GRATING - 1" x 1/8" BEARING BARS (MAX OPENING 4"). FASTEN WITH TYPE J CLIPS. ATTACH TO 1-1/4" x 1-1/4" x1/4" GALVANIZED ANGLE FRAME. MORTAR FRAME TO TOP OF OUTLET STRUCTURE & FACE OF WEIR. TOP OF BANK 15" RCP 1 3 6" 15" RCP A NORMAL POOL 44.7 2.5 1 12 " 3' - 0 " 6" 6" A 6" TOP OF BOX 47.0 NTS DETENTION POND OUTLET STRUCTURE 4" SCREW TYPE PLUG 4" PVC PIPE 4" PVC CAP W/ 1.5" DRILLED HOLE ORIFICE W/ GALVANIZED WIRE CLOTH OVER SMALL DIAMETER ORIFICE (8 MESH .020 WIRE) 24.0" WEIR INV. 46.25 FLOOD POOL 46.25 12 " ș WATER SURFACE FRONT VIEWEND VIEW PROSEPECTIVE VIEW PVC ELBOW PVC TEE PVC END CAP PVC END CAP PVC PIPE (8) 12" HOLES IN UNDERSIDE ARM ASSEMBLY "C" ENCLOSURE WATER ENTRY UNIT SCEHDULE 40 PVC PIPE PVC TEE ORIFICE PLATE (SEE SIZE BELOW) SCHEDULE 40 PVC PIPE (SEE SIZE BELOW) FLEXIBLE HOSE CONNECTED TO OUTLET STRUCTURE ORIFICE PVC PIPE VENT NTS FAIRCLOTH SKIMMER DETAIL 1. SKIMMER TO BE USED IN WET PONDS AND REMOVED AFTER SITE IS PERMANENTLY STABLE. NOTES: SKIMMER SPECS: SIZE=2.0" SCH-40 PVC PIPE ORIFICE=1.9" DIAMETER 4" CONC. SIDEWALK w/6x6-10/10 W.W.M. 4"8" x x x x x GRAVEL/CONC. TURNDOWN SIDEWALK NTS CLASS A CONC. 7"1/8"R 1"3"R 6" 1 1/2"R 3"R 1' - 0 " 2'-0" 1'-6"6" ASPHALT DRAINAGE AWAY FROM CURB CLASS A CONC. 24" CURB SECTION NTS ASPHALT 7" 2'-0" 3"R 1'-6" 1/8"R 1" 6" 6" 1' - 0 " DRAINAGE TOWARD CURB SHALL SLOPE AWAY AS SHOWN AWAY FROM CURB, GUTTER WHERE RUNOFF IS DIRECTED SLOPE SLOPE 1 1/2"R 3"R 4" ABC STONE COMPACTED SUB-GRADE GRAVEL SECTION NTS BOTTOM OF SPILLWAY EL. 47.8 3 1 31 TOP OF BANK 10' 1 3 60' EL. 47.8 EL. 48.0 EMERGENCY SPILLWAY DETAIL NTS EL. 48.0 NOTES: 1. WIDTH OF SPILLWAY TO BE PROTECTED WITH RIPRAP AS SHOWN ON PLAN. REMAINING LENGTH OF CHANNEL TO BE STABILIZED WITH EXCELSIOR MAT AND SEEDED IN ACCORDANCE WITH SPECIFICATIONS. 1" DIA ROD @ 5' MAX SPACING LANDSCAPE ISLAND 2' 6" X 6" LANDSCAPE TIMBERS PARKING SUFACE 6" NTS TYPICAL TIMBER PARKING EDGING DETAIL