Loading...
20230315 - Take 5 Car Wash Site Plan_v1SITE SITE U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C O V E R & N O T E S . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 3 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - CS0001 BY NO . DA T E RE V I S I O N S TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S CO V E R S H E E T DRVBR22040 AS SHOWN DTR 03/15/2023 ESM SHEET APPROVED BY OF1 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PREPARED FOR: DEVELOPER/ APPLICANT DRIVEN BRANDS 440 SOUTH CHURCH STREET, SUITE 700 CHARLOTTE, NC 28202 TAKE 5 CAR WASH   LAND DEVELOPMENT 8232 MARKET STREET WILMINGTON, NEW HANOVER COUNTY, NC 03/15/2023 VICINITY MAP Scale: 1" = 1000' SOILS MAP Scale: 1" = 1000' NO R T H 5430 Wade Park Boulevard Suite 106 Raleigh, NC 27607 T 919.929.1173 F 919.493.6548 Firm License F-1267 PREPARED BY: PENNONI ASSOCIATES INC. Sheet List Table Sheet Number Sheet Title Sheet Description 1 CS0001 COVER SHEET 2 CS0002 GENERAL NOTES 3 CS0201 EXISTING CONDITIONS PLAN 4 CS0501 DEMOLITION PLAN 5 CS1001 SITE PLAN 6 CS1501 GRADING PLAN 7 CS1701 UTILITY PLAN 8 CS2001 LANDSCPAING PLAN 9 CS2002 EXISTING TREE PLAN 10 CS2003 LANDSCAPING NOTES AND DETAILS 11 CS6001 SITE DETAILS 12 CS6021 DRAINAGE DETAILS 13 CS6041 UTILITY DETAILS 14 CS8001 EROSION CONTROL PLAN PH1 15 CS8002 EROSION CONTROL PLAN PH2 16 CS8501 EROSION CONTROL DETAILS 17 CS8502 EROSION CONTROL DETAILS 18 CS8503 EROSION CONTROL DETAILS 19 CS9201 PRE/POST DEVELOPMENT IMPERVIOUS AREA 20 CS9202 POST DEVELOPMENT INLET DRAINAGE AREA MAP 21 CS9801 GARBAGE TRUCK TURN AND FIRE TRUCK APPARATUS ACCESS PLAN Property Information PROPERTY ADDRESS 8232 MARKET STREET WILMINGTON, NC 28411 DEVELOPER/ APPLICANT DRIVEN BRANDS CONTACT NAME: REBECCA MCALLISTER OR MATT GILBERT 440 SOUTH CHURCH STREET, SUITE 700 CHARLOTTE, NC 28202 EXISTING USE RESTAURANT INTENDED USE CAR WASH DATUM AND BENCHMARK INFORMATION HORIZONTAL DATUM: THE BASIS OF BEARING FOR THIS SURVEY IS NCGS GRID NORTH (NAD 83, 2011), AS SHOWN HEREON VERTICAL DATUM: ELEVATIONS SHOWN HEREON ARE REFERENCED TO NAVD 88. PARCEL PIN 3260-51-1470 EXISTING AND PROPOSED ZONING B-1 - NEIGHBORHOOD BUSINESS LOT AREA MIN. REQUIRED: NA PROPOSED: 65,575.35 SF (1.51 AC) LOT WIDTH REQUIRED: NA PROPOSED: 157 FT BUILDING SETBACKS SIDE: 25 FT STREET: 75 FT (25% REDUCTION UTILIZED) BUFFERYARDS REQUIRED: SIDE (NORTHEAST): 10 FT SIDE (SOUTHWEST):10 FT REAR (SOUTHEAST):0 FT STREETYARDS REQUIRED: FRONT (MARKET SREET): 25 FT BUILDING HEIGHT MAX: 35 FT PROPOSED: 32 FT VEHICULAR PARKING REQUIRED: 4 (1 PER 250 SQ-FT) PROPOSED: 6 STANDARD (1,020 SF BLDG AREA) AND 1 VAN ACCESSIBLE FOR EMPLOYEE SPACES 11 STANDARD VACUUM AND 1 VAN ACCESSIBLE VACUUM TOTAL:17 BICYCLE PARKING REQUIRED:1 (ST: 0.05 X REQUIRED VEHICULAR PARKING) PROPOSED:2 (1 INVERTED U) FLOOR TO AREA RATIO BUILDING AREA: 3778.67 SF (0.09 AC) PROPERTY AREA:65,575.35 SF (1.51 AC) FAR:0.06 LOT COVERAGE LIMITS OF DISTURBANCE: 1.28 AC PRE-DEVELOPMENT IMPERVIOUS AREA: 38,345.56 SF (0.88 AC.) PERVIOUS AREA: 27,229.79 SF (0.63 AC.) POST-DEVELOPMENT IMPERVIOUS AREA: 25,775.84 SF (0.59 AC.) PERVIOUS AREA: 39,799.51 SF (0.92 AC.) SEWER FLOW 125 GPM (AVG.) & 180,000 GPD (AVG.) 312.5 GPM (PEAK) WATER REQUIREMENTS WATER DOMESTIC:125 GPM - 2" METER FLOOD ZONE ZONE X NO R T H DESIGN TEAM: DEVELOPER/ APPLICANT: REBECCA MCALLISTER DRIVEN BRANDS 440 SOUTH CHURCH STREET, SUITE 700 CHARLOTTE, NC 28202 PHONE # TBD REBECCA.MCALLISTER@DRIVENBRANDS.COM ENGINEER: ETHAN MINDREBO, PE PENNONI ASSOCIATES 5430 WADE PARK BLVD - SUITE 106 RALEIGH, NC 27607 919-230-9217 EMINDREBO@PENNONI.COM ARCHITECT: MICAH SMITH COR3 DESIGN 125 RHETT ST - SUITE 101 GREENVILLE, SC 29601 864-990-3079 MSMITH@COR3DESIGN.COM SURVEYOR: JIMMY F. CAIN CAIN SURVEYING, P.C. 6333 N.C. HIGHWAY #242 SOUTH BLADENBORO, NC 28320 910-648-4509 JIMMY@CAINSURVEYING.COM U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C O V E R & N O T E S . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 3 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - CS0002 TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S DRVBR22040 AS SHOWN DTR 03/15/2023 ESM SHEET APPROVED BY OF2 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K GE N E R A L N O T E S PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d , # 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 1.DEVELOPER/APPLICANT: RESPONSIBLE OFFICER: DRIVEN BRANDS REBECCA MCALLISTER 440 SOUTH CHURCH STREET, SUITE 700 REBECCA.MCALLISTER@DRIVENBRANDS.COM CHARLOTTE, NC 28202 PROPERTY OWNER: HUTSON AND NIEPER ENTERPRISES LLC 8232 MARKET STREET WILMINGTON, NC 28411 2.EXISTING TOPOGRAPHIC FEATURES WERE TAKEN FROM AN ALTA SURVEY PLAN PROVIDED BY CAIN SURVEYING, P.C. AND FIELD WORK COMPLETED OCTOBER 3, 2022. 3.EXISTING SUBSURFACE CONDITIONS WERE TAKEN FROM "SUMMARY OF UNDERGROUND UTILITY LOCATING" REPORT PERFORMED BY GPRS INC DATED SEPTEMBER 16, 2022. 4.UTILITY NOTES: A. COMPLETENESS OR ACCURACY OF LOCATION AND DEPTH OF UNDERGROUND UTILITIES AND STRUCTURES IS NOT GUARANTEED. B. LOCATION OF ALL EXISTING AND PROPOSED SERVICES ARE APPROXIMATE AND SHALL BE CONFIRMED INDEPENDENTLY WITH LOCAL UTILITY COMPANIES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION OR EXCAVATION. SANITARY SEWER AND ALL OTHER UTILITY SERVICE CONNECTION POINTS SHALL BE CONFIRMED INDEPENDENTLY BY THE CONTRACTOR IN THE FIELD PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. ALL DISCREPANCIES SHALL BE REPORTED IMMEDIATELY IN WRITING TO THE ENGINEER. CONSTRUCTION SHALL COMMENCE BEGINNING AT THE LOWEST INVERT (POINT OF CONNECTION) AND PROGRESS UP GRADIENT. PROPOSED INTERFACE POINTS (CROSSINGS) WITH EXISTING UNDERGROUND UTILITIES SHALL BE FIELD VERIFIED BY TEST PIT PRIOR TO COMMENCEMENT OF CONSTRUCTION. C. ALL UTILITIES AND SERVICES INCLUDING BUT NOT LIMITED TO GAS, WATER, ELECTRIC, SANITARY AND STORM SEWER, TELEPHONE, CABLE, FIBER OPTIC, ETC. WITHIN THE LIMITS OF DISTURBANCE SHALL BE VERTICALLY AND HORIZONTALLY LOCATED. THE CONTRACTOR SHALL USE AND COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE UTILITY NOTIFICATION SYSTEM TO LOCATE ALL THE UNDERGROUND UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRS OF DAMAGE TO ANY EXISTING UTILITIES DURING CONSTRUCTION AT NO COST TO THE OWNER. 5.THE PROPERTY DELINEATED HEREON IS LOCATED IN UNSHADED ZONE "X" AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN AND FUTURE CONDITIONS 1% ANNUAL CHANCE FLOODPLAIN AS DETERMINED BY REFERENCE TO FIRM COMMUNITY PANEL NO. 3710456500K, DATED FEBRUARY 19, 2014, AS PUBLISHED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY. 6.FIRE WATCH; DURING CONSTRUCTION AND DEMOLITION WHERE HOT WORK, MATERIALS SUBJECT TO SPONTANEOUS COMBUSTION, OR OTHER HAZARDOUS CONSTRUCTION OR DEMOLITION IS OCCURRING, THE OWNER OR THEIR DESIGNEE SHALL BE RESPONSIBLE FOR MAINTAINING A FIRE WATCH. THE FIRE WATCH SHALL CONSIST OF AT LEAST ONE PERSON WITH A MEANS OF COMMUNICATING AN ALARM TO 911, SHALL A WRITTEN ADDRESS POSTED IN A CONSPICUOUS LOCATION AND SHALL MAINTAIN CONSTANT PATROLS. NC FPC 2012 SECTION 1404. 7.CONSTRUCTION/DEMOLITION; ALL CONSTRUCTION AND DEMOLITION CONDUCTED, SHALL BE IN COMPLIANCE OF THE CURRENT EDITION OF CHAPTER 14 OF THE NC FPC. 8.PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY APPLICANT SHALL REPLACE ANY TREES SHOWN AS PRESERVED-PROTECTED ON THE LANDSCAPE PROTECTION PLAN THAT HAVE DIED OR ARE IN POOR HEALTH AS A RESULT OF LAND DISTURBING ACTIVITIES. 9.TOTAL PROJECT DISTURBANCE 1.33 AC. 10.CURB RADII DIMENSIONS ARE SHOWN TO THE FACE OF CURB WITHIN THE PLAN SET. GENERAL NOTES: 1.ALL WORK SHALL COMPLY WITH APPLICABLE STATE, FEDERAL AND LOCAL CODES AND OSHA STANDARDS ALL NECESSARY LICENSES AND PERMITS SHALL BE OBTAINED BY THE CONTRACTOR AT HIS EXPENSE UNLESS PREVIOUSLY OBTAINED BY THE OWNER/DEVELOPER. 2.THE CONTRACTOR SHALL BE REQUIRED TO REVIEW AND ABIDE BY SPECIFICATIONS OF THE PLAN AND ALL SUPPORTING DOCUMENTS, PERMITS, AND REPORTS FOR THIS SITE, INCLUDING NOT BUT NOT LIMITED TO: ·EROSION AND SEDIMENTATION CONTROL PLAN ·STORMWATER MANAGEMENT PLAN. 3.THE CONTRACTOR SHALL IMMEDIATELY INFORM THE ENGINEER OF ANY DISCREPANCIES OR ERROR THEY DISCOVER IN THE PLANS. 4.DEVIATION FROM THESE PLANS AND NOTES WITHOUT THE PRIOR CONSENT OF THE OWNER OR HIS REPRESENTATIVE OR THE ENGINEER MAY BE CAUSE OF THE WORK TO BE UNACCEPTABLE. 5.UTILITY COORDINATION SHALL BE INCLUDED IN THE PROJECT SCHEDULE AND IT IS THE EXPLICIT RESPONSIBILITY OF THE CONTRACTOR TO ASSURE THAT THE PROJECT SCHEDULE INCLUDES THE NECESSARY RELOCATIONS. THE CONTRACTOR WILL NOT BE PAID ADDITIONALLY FOR THIS COORDINATION. THE CONTRACTOR SHOULD SEEK ASSISTANCE FROM ALL UTILITY COMPANIES TO LOCATE AND PROTECT THEIR FACILITIES. IF CONFLICTS ARE FOUND, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND DESIGN ENGINEER FOR INSTRUCTION BEFORE PROCEEDING WITH WORK. 6.ALL MATERIALS SHALL BE NEW UNLESS USED OR SALVAGED MATERIALS ARE AUTHORIZED BY THE OWNER AND APPLICANT. 7.TRAFFIC CONTROL METHODS, SUCH AS BARRICADES, SUFFICIENT LIGHTS, SIGNS, ETC., MAY BE NECESSARY FOR THE PROTECTION AND SAFETY OF THE PUBLIC SHALL BE PROVIDED AND MAINTAINED THROUGHOUT THE CONSTRUCTION IN ACCORDANCE WITH CURRENT AND NCDOT STANDARDS. 8.CONTRACTOR SHALL FURNISH AND MAINTAIN ALL NECESSARY BARRICADES, FENCING AND OTHER APPROPRIATE SAFETY ITEMS/MEASURES NECESSARY TO PROTECT THE PUBLIC FROM THE WORK AREA CONSTRUCTION ACTIVITIES. 9.HIGH INTENSITY LIGHTING FACILITIES SHALL BE SO ARRANGED THAT THE SOURCE OF ANY LIGHT IS CONCEALED FROM PUBLIC VIEW AND FROM ADJACENT RESIDENTIAL PROPERTY AND DOES NOT INTERFERE WITH TRAFFIC. 10.THE CONTRACTOR SHALL MAINTAIN ACCESS FOR EMERGENCY VEHICLES AROUND AND TO ALL BUILDINGS NEAR CONSTRUCTION. IN TIME OF RAIN OR MUD, ROADS SHALL BE ABLE TO CARRY A FIRE TRUCK BY BEING PAVED OR HAVING A CRUSHED STONE BASE, ETC., WITH A MINIMUM WIDTH OF 20 FEET. ACCESS TO BUILDINGS THAT HAVE SPRINKLER OR STANDPIPE SYSTEMS SHALL BE WITHIN 40 FEET OF THE FIRE DEPARTMENT CONNECTOR. (NFPA 1141 3-1) 11.BEDDING REQUIREMENTS SPECIFIED HEREIN ARE TO BE CONSIDERED AS MINIMUMS FOR RELATIVELY DRY, STABLE EARTH CONDITIONS. ADDITIONALLY BEDDING SHALL BE REQUIRED FOR ROCK TRENCHES AND WET AREAS. CONTRACTOR SHALL HAVE THE RESPONSIBILITY TO PROVIDE SUCH ADDITIONAL BEDDING AS MAY BE REQUIRED TO PROPERLY CONSTRUCT THE WORK. 12.BACKFILL OF ALL TRENCHES SHALL BE COMPACTED TO THE DENSITY OF 95% OF THEORETICAL MAXIMUM DRY DENSITY (ASTM D698). BACKFILL MATERIAL SHALL BE FREE FROM ROOTS, STUMPS, OR OTHER FOREIGN DEBRIS AND SHALL BE PLACED IN LAYERS NOT TO EXCEED SIX (6) INCHES IN COMPACTED FILL THICKNESS. A REPORT FROM A GEOTECHNICAL ENGINEER MAY BE REQUIRED BY THE PUBLIC WORKS INSPECTOR. CORRECTION OF ANY TRENCH SETTLEMENT WITHIN A YEAR FROM THE DATE OF APPROVAL WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 13.THE CONTRACTOR WILL ENSURE THAT POSITIVE AND ADEQUATE DRAINAGE IS MAINTAINED AT ALL TIMES WITHIN THE PROJECT LIMITS. THIS MAY INCLUDE, BUT NOT BE LIMITED TO, A) REPLACEMENT OR RECONSTRUCTION OF EXISTING DRAINAGE STRUCTURES THAT HAVE BEEN DAMAGED OR REMOVED, OR B) REGRADING AS REQUIRED BY THE ENGINEER, EXCEPT FOR THOSE DRAINAGE ITEMS SHOWN AT SPECIFIC LOCATIONS AND HAVING SPECIFIC PAY ITEMS IN THE DETAILED ESTIMATE. NO SEPARATE PAYMENT WILL BE MADE FOR ANY COSTS INCURRED TO COMPLY WITH THIS REQUIREMENT. 14.THE CONTRACTOR SHALL PROVIDE ANY AND ALL EXCAVATION AND MATERIAL SAMPLES NECESSARY TO CONDUCT REQUIRED SOIL TESTS. ALL ARRANGEMENTS AND SCHEDULING FOR THE TESTING SHALL BE THE CONTRACTOR'S RESPONSIBILITY. 15.SOIL TESTING AND ON-SITE INSPECTION SHALL BE PERFORMED BY AN INDEPENDENT GEOTECHNICAL ENGINEER. A GEOTECHNICAL ENGINEER IS REQUIRED TO INSPECT, TEST AND CERTIFY TO THE COMPACTION OF ALL LOAD BEARING FILLS. THE GEOTECHNICAL ENGINEER SHALL PROVIDE COPIES OF TEST REPORTS TO THE CONTRACTOR, THE OWNER AND TO THE OWNER'S REPRESENTATIVE AND SHALL PROMPTLY NOTIFY THE OWNER, HIS REPRESENTATIVE AND THE CONTRACTOR, SHOULD WORK PERFORMED BY THE CONTRACTOR FAIL TO MEET THESE SPECIFICATIONS. 16.ALL PERMITS MUST BE OBTAINED PRIOR TO THE START OF CONSTRUCTION. 17.ALL PAVEMENT MARKINGS AND REGULATORY SIGNS ON PRIVATE PROPERTY SHALL CONFORM TO CURRENT MUTCD STANDARDS. GENERAL CONSTRUCTION AND GRADING NOTES: 1.ALL UTILITIES AND SERVICES INCLUDING BUT NOT LIMITED TO GAS, WATER, ELECTRIC, SANITARY AND STORM SEWER, TELEPHONE, CABLE, FIBER OPTIC, ETC. WITHIN THE LIMITS OF DISTURBANCE SHALL BE VERTICALLY AND HORIZONTALLY LOCATED. THE CONTRACTOR SHALL USE AND COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE UTILITY NOTIFICATION SYSTEM TO LOCATE ALL THE UNDERGROUND UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRS OF DAMAGE TO ANY EXISTING UTILITIES DURING CONSTRUCTION AT NO COST TO THE OWNER. 2.UTILITY COORDINATION SHALL BE INCLUDED IN THE PROJECT SCHEDULE AND IT IS THE EXPLICIT RESPONSIBILITY OF THE CONTRACTOR TO ASSURE THAT THE PROJECT SCHEDULE INCLUDES THE NECESSARY RELOCATIONS. THE CONTRACTOR WILL NOT BE PAID ADDITIONALLY FOR THIS COORDINATION. 3.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE LOCATIONS AND DEPTHS OF ALL EXISTING UNDERGROUND UTILITIES AND STRUCTURES BEFORE THE START OF WORK AND TO TAKE WHATEVER STEPS NECESSARY TO PROVIDE FOR THEIR PROTECTION. THE ENGINEER HAS DILIGENTLY ATTEMPTED TO LOCATE AND INDICATE ALL EXISTING FACILITIES ON THESE PLANS; HOWEVER, THIS INFORMATION IS SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS OF UTILITIES SHOWN OR NOT SHOWN. COMPLETENESS OR ACCURACY OF LOCATION AND DEPTH OF UNDERGROUND UTILITIES AND STRUCTURES IS NOT GUARANTEED. 4.THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES FOR EXACT LOCATION AND PROTECTION OF THEIR UTILITIES PRIOR TO STARTING CONSTRUCTION. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR AND REPLACE ANY AND ALL DAMAGE MADE TO UTILITIES BY THE CONTRACTOR. 5.CONTRACTOR MUST APPLY FOR ALL UTILITY CONNECTION APPLICATIONS. CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY CONNECTION FEES FOR CONSTRUCTION. REFER TO COVER SHEET FOR AVAILABLE UTILITY COMPANY LIST. 6.CONTRACTOR MUST OBTAIN ANY REQUIRED UTILITY DETAILS FOR RECONNECTION OF EXISTING SERVICES OR NEW SERVICE AND IS RESPONSIBLE FOR THE CONSTRUCTION OF EACH NEW SERVICE PER THE APPROPRIATE UTILITY COMPANY'S SPECIFICATIONS. 7.THE CONTRACTOR SHALL COORDINATE LOCATION AND INSTALLATION OF ALL UNDERGROUND UTILITIES AND APPURTENANCES TO MINIMIZE DISTURBANCE TO CURBING, PAVING, AND COMPACTED SUB-GRADE. 8.IF CONFLICTS ARE FOUND, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND ENGINEER FOR INSTRUCTION BEFORE PROCEEDING WITH WORK. 9.ALL PIPE LENGTHS AND DISTANCES BETWEEN STRUCTURES ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE ALONG A HORIZONTAL PLANE. 10.THE CONTRACTOR SHALL PROVIDE ANY AND ALL EXCAVATION AND MATERIAL SAMPLES NECESSARY TO CONDUCT REQUIRED SOIL TESTS. ALL ARRANGEMENTS AND SCHEDULING FOR THE TESTING SHALL BE THE CONTRACTOR'S RESPONSIBILITY. 11.SOILS TESTING AND ON-SITE INSPECTION SHALL BE PERFORMED BY AN INDEPENDENT GEOTECHNICAL ENGINEER. THE SOILS ENGINEER SHALL PROVIDE COPIES OF TEST REPORTS TO THE CONTRACTOR, THE OWNER AND THE OWNER'S REPRESENTATIVE AND SHALL PROMPTLY NOTIFY THE OWNER, HIS REPRESENTATIVE AND THE CONTRACTOR SHOULD WORK PERFORMED BY THE CONTRACTOR FAIL TO MEET THESE SPECIFICATIONS. 12.CONTRACTOR SHALL EXCAVATE ONLY ENOUGH TRENCH FOR WHICH PIPE CAN BE INSTALLED AND TRENCH BACKFILLED BY THE END OF EACH WORK DAY. 13.BEDDING REQUIREMENTS SPECIFIED HEREIN ARE TO BE CONSIDERED AS MINIMUMS FOR RELATIVELY DRY, STABLE EARTH CONDITIONS. ADDITIONAL BEDDING SHALL BE REQUIRED FOR ROCK TRENCHES AND WET AREAS. CONTRACTOR SHALL HAVE THE RESPONSIBILITY TO PROVIDE SUCH ADDITIONAL BEDDING AS MAY BE REQUIRED TO PROPERLY CONSTRUCT THE WORK. 14.COMPACTION OF THE BACKFILL OF ALL TRENCHES SHALL BE COMPACTED TO THE DENSITY OF 95% OF THEORETICAL MAXIMUM DRY DENSITY (ASTM D698). BACKFILL MATERIAL SHALL BE FREE FROM ROOTS, STUMPS, OR OTHER FOREIGN DEBRIS AND SHALL BE PLACED IN LIFTS NOT TO EXCEED 6 INCHES IN COMPACTED FILL THICKNESS. A REPORT FROM A GEOTECHNICAL ENGINEER MAY BE REQUIRED BY THE PUBLIC WORKS INSPECTOR. CORRECTION OF ANY TRENCH SETTLEMENT WITHIN A YEAR FROM THE DATE OF APPROVAL WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 15.RUNOFF FROM IMPERVIOUS AREAS SHALL NOT BE DIRECTED INTO THE SANITARY SEWER NOR ONTO ADJACENT PROPERTIES. 16.ALL JOINTS ON THE STORM WATER CONVEYANCE SYSTEM SHALL BE WATERTIGHT. 17.ALL CONSTRUCTION ASSOCIATED WITH WATER AND SANITARY SEWER SHALL BE IN ACCORDANCE WITH C.F.P.U.A. STANDARDS AND SPECIFICATIONS. 18.ALL ELECTRICAL SERVICE LINES TO OR AROUND THE PROPOSED STRUCTURE SHALL BE UNDERGROUND. GENERAL UTILITY NOTES: 1.HORIZONTAL AND VERTICAL SEPARATION 1.1.SANITARY SEWERS SHALL BE LAID AT LEAST 10-FEET HORIZONTALLY FROM ANY EXISTING OR PROPOSED WATER MAIN. THE DISTANCE SHALL BE MEASURED EDGE TO EDGE. IN CASES WHERE IT IS NOT PRACTICAL TO MAINTAIN A 10-FOOT SEPARATION, THE PUBLIC WORKS SUPPLY MAY ALLOW DEVIATION A CASE-BY-CASE BASIS, IF SUPPORTED BY DATA FROM THE DESIGN ENGINEER. SUCH DEVIATION ON MAY ALLOW THE INSTALLATION OF THE SANITARY SEWER CLOSER TO A WATER MAIN, PROVIDED THAT THE WATER MAIN IS IN A SEPARATE TRENCH OR ON AN UNDISTURBED EARTH SHELF LOCATED ON ONE SIDE OF THE SANITARY SEWER AND AT AN ELEVATION SO THE BOTTOM OF THE WATER MAIN IS AT LEAST 18-INCHES ABOVE THE TOP OF THE SEWER. 1.2.IF IT IS IMPOSSIBLE TO OBTAIN PROPER HORIZONTAL AND VERTICAL SEPARATION AS DESCRIBED ABOVE OR ANYTIME THE SANITARY SEWER IS OVER THE WATER MAIN, BOTH THE WATER MAIN AND SANITARY SEWER MUST BE CONSTRUCTED OF FERROUS PIPE COMPLYING WITH THE PUBLIC WATER SUPPLY DESIGN STANDARDS AND BE PRESSURE TESTED TO 150PSI TO ASSURE WATER TIGHTNESS BEFORE BACKFILLING. 1.3.A 24-INCH VERTICAL AND 10-FOOT HORIZONTAL SEPARATION SHALL BE PROVIDED BETWEEN STORM SEWER AND SANITARY SEWER LINES OR FERROUS PIPE SPECIFIED. A 18-INCH VERTICAL SEPARATION SHALL BE PROVIDED BETWEEN STORM SEWER AND WATER MAIN. 1.3.1.IF A 18-INCH VERTICAL SEPARATION IS NOT MAINTAINED AT A CROSSING BETWEEN STORM SEWER AND WATER MAINS (OR PRESSURE SEWERS). THE WATER MAIN SHALL BE CONSTRUCTED OF FERROUS PIPE AND A CONCRETE COLLAR SHALL BE POURED AROUND WATER MAINS AND STORM SEWER TO IMMOBILIZE THE CROSSING. 2.CROSSINGS 1.1.SANITARY SEWER CROSSING WATER MAINS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 24 INCHES BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF THE SANITARY SEWER. THE CROSSING SHALL BE ARRANGED SO THAT THE SANITARY SEWER JOINTS WILL BE EQUIDISTANT AND AS FAR AS POSSIBLE FROM THE WATER MAIN JOINTS. 1.2.WHEN IT IS IMPOSSIBLE TO OBTAIN PROPER HORIZONTAL AND VERTICAL SEPARATION AS STIPULATED ABOVE, ONE OF THE FOLLOWING METHODS MUST BE SPECIFIED: 1.1.1.THE SANITARY SEWER SHALL BE DESIGNED AND CONSTRUCTED OF FERROUS PIPE AND SHALL BE PRESSURE TESTED AT 150-PSI TO ASSURE WATER TIGHTNESS PRIOR TO BACKFILLING, OR 1.1.2.EITHER THE WATER MAIN OR THE SANITARY SEWER LINE MAY BE ENCASED IN A WATERTIGHT CARRIER PIPE, WHICH EXTENDS 10-FEET ON BOTH SIDES OF THE CROSSING, MEASURED PERPENDICULAR TO THE WATER MAIN. THE CARRIER PIPE SHALL BE OF MATERIALS APPROVED BY THE PUBLIC WATER SUPPLY FOR USE IN WATER MAIN CONSTRUCTION. CONTRACTORS MUST EXERCISE APPROPRIATE CARE AND PRECISION IN CONSTRUCTION OF ADA (HANDICAP) ACCESSIBLE COMPONENTS AND ACCESS ROUTES FOR THE SITE. THESE COMPONENTS, AS CONSTRUCTED, MUST COMPLY WITH THE CURRENT ADA STANDARDS AND REGULATIONS' BARRIER FREE ACCESS AND ANY MODIFICATIONS, REVISIONS OR UPDATES TO SAME. FINISHED SURFACES ALONG THE ACCESSIBLE ROUTE OF TRAVEL FROM PARKING SPACE(S), PUBLIC TRANSPORTATION, PEDESTRIAN ACCESS, INTER-BUILDING ACCESS, TO POINTS OF ACCESSIBLE BUILDING ENTRANCE/EXIT, MUST COMPLY WITH THESE ADA CODE REQUIREMENTS. THESE INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: 1.PARKING SPACES AND PARKING AISLES - SLOPE SHALL NOT EXCEED 1:50 (1/4” PER FOOT OR NOMINALLY 2.0%) IN ANY DIRECTION. 2.CURB RAMPS - SLOPE MUST NOT EXCEED 1:12 (8.3%) FOR A MAXIMUM OF SIX (6) FEET. 3.LANDINGS - MUST BE PROVIDED AT EACH END OF RAMPS, MUST PROVIDE POSITIVE DRAINAGE, AND MUST NOT EXCEED 1:50 (1/4” PER FOOT OR NOMINALLY 2.0%) IN ANY DIRECTION. 4.PATH OF TRAVEL ALONG ACCESSIBLE ROUTE - MUST PROVIDE A 36-INCH OR GREATER UNOBSTRUCTED WIDTH OF TRAVEL (CAR OVERHANGS AND/OR HANDRAILS CANNOT REDUCE THIS MINIMUM WIDTH). THE SLOPE MUST BE NO GREATER THAN 1:20 (5.0%) IN THE DIRECTION OF TRAVEL, AND MUST NOT EXCEED 1:50 (1/4” PER FOOT OR NOMINALLY 2.0%) IN CROSS SLOPE. WHERE PATH OF TRAVEL WILL BE GREATER THAN 1:20 (5.0%), ADA RAMP REGULATIONS MUST BE ADHERED TO. A MAXIMUM SLOPE OF 1:12 (8.3%), FOR A MAXIMUM RISE OF 2.5 FEET, MUST BE PROVIDED. THE RAMP MUST HAVE ADA HAND RAILS AND “LEVEL” LANDINGS ON EACH END THAT ARE CROSS SLOPED NO MORE THAN 1:50 IN ANY DIRECTION (1/4” PER FOOT OR NOMINALLY 2.0%) FOR POSITIVE DRAINAGE. 5.DOORWAYS - MUST HAVE A “LEVEL” LANDING AREA ON THE EXTERIOR SIDE OF THE DOOR THAT IS SLOPED AWAY FROM THE DOOR NO MORE THAN 1:50 (1/4” PER FOOT OR NOMINALLY 2.0%) FOR POSITIVE DRAINAGE. THIS LANDING AREA MUST BE NO LESS THAN 60 INCHES (5 FEET) LONG, EXCEPT WHERE OTHERWISE PERMITTED BY ADA STANDARDS FOR ALTERNATIVE DOORWAY OPENING CONDITIONS. (SEE ICC/ANSI A117.1-2003 AND OTHER REFERENCED INCORPORATED BY COD.) 6.WHEN THE PROPOSED CONSTRUCTION INVOLVES RECONSTRUCTION, MODIFICATION, REVISION OR EXTENSION OF OR TO ADA COMPONENTS FROM EXISTING DOORWAYS OR SURFACES, CONTRACTOR MUST VERIFY EXISTING ELEVATIONS SHOWN ON THE PLAN. NOTE THAT TABLE 405.2 OF THE DEPARTMENT OF JUSTICE'S ADA STANDARDS FOR ACCESSIBLE DESIGN ALLOWS FOR STEEPER RAMP SLOPES, IN RARE CIRCUMSTANCES. PRIOR TO THE COMMENCEMENT OF WORK, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE DESIGN ENGINEER IN WRITING OF ANY DISCREPANCIES AND/OR FIELD CONDITIONS THAT DIFFER IN ANY WAY OR ANY RESPECT FROM WHAT IS SHOWN ON THE PLANS, IN WRITING, BEFORE COMMENCEMENT OF WORK. CONSTRUCTED IMPROVEMENTS MUST FALL WITHIN THE MAXIMUM AND MINIMUM LIMITATIONS IMPOSED BY THE BARRIER FREE REGULATIONS AND THE ADA REQUIREMENTS. 7.THE CONTRACTOR MUST VERIFY THE SLOPES OF CONTRACTOR'S FORMS PRIOR TO POURING CONCRETE. IF ANY NON-CONFORMANCE IS OBSERVED OR EXISTS, CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER PRIOR TO POURING CONCRETE. CONTRACTOR IS RESPONSIBLE FOR ALL COSTS TO REMOVE, REPAIR AND REPLACE NON-CONFORMING CONCRETE. 8.THE SITE SHALL BE FULLY COMPLIANT WITH THE NORTH CAROLINA ACCESSIBILITY CODES (ANSI 117.1 -2009 AND CHAPTER 11 OF THE NCBC) UNLESS AND EXCEPT IN AREAS WHERE AN APPROVED STATEMENT FROM A SITE ENGINEER, SURVEYOR OR ARCHITECT VERIFIES THAT SITE CONDITIONS EXIST WHERE THE TOPOGRAPHY OF THE SITE IS EXTREME AND ONLY ALTERNATE METHODS OF COMPLIANCE ARE POSSIBLE. 9.ACCESSIBILITY REQUIREMENTS: THAT PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY, THE APPLICANT SHALL PROVIDE THE MINIMUM REQUIRED HANDICAPPED PARKING SPACES AND DESIGN ALL HANDICAPPED PARKING SPACES, RAMPS, AND CROSSWALKS, AND ASSOCIATED INFRASTRUCTURE ACCORDING TO AMERICANS WITH DISABILITIES ACT STANDARDS, NORTH CAROLINA BUILDING CODE, AMERICAN NATIONAL STANDARDS INSTITUTE ANSI CODE, AND TOWN STANDARD.1. PARKING - NUMBER OF SPACES TO COMPLY WITH NCBC 2012 SECTION 1106.1, 1 PER 6 COMPLIANT SPACES OR PORTION THEREOF MUST BE VAN ACCESSIBLE, NO SLOPE TO EXCEED 2 PERCENT IN ANY DIRECTION. SIGNAGE PER NC REQUIREMENTS, MUT-CD AND ICC A 117.1.2. CURB CUTS AND ACCESSIBLE ROUTES PER ICC A117.1 2009 ED. CROSS SLOPE LIMITED TO 2 PERCENT, CALL FOR INSPECTION BEFORE PLACEMENT OF CONCRETE. A SLOPE GREATER THAN 5 PERCENT REQUIRES CONSTRUCTION AS A RAMP. IT IS STRONGLY RECOMMENDED THAT THE CONTRACTOR REVIEW THE INTENDED CONSTRUCTION WITH THE LOCAL BUILDING CODE PRIOR TO COMMENCEMENT OF CONSTRUCTION. ADA INSTRUCTIONS TO CONTRACTOR: WATER AND SEWER SERVICE NOTES: 1.FIRE APPARATUS ACCESS ROADS; ANY FIRE APPARATUS ACCESS ROADS, ANY PUBLIC/PRIVATE STREET, PARKING LOT ACCESS, FIRE LANES AND ACCESS ROADWAYS, USED FOR FIRE DEPARTMENT ACCESS SHALL BE ALL WEATHER AND DESIGNED TO CARRY THE IMPOSED LOAD OF FIRE APPARATUS WEIGHING AT LEAST 80,000 LBS. FIRE APPARATUS ACCESS ROADS SHALL HAVE A MINIMUM WIDTH OF 20' EXCLUSIVE OF SHOULDERS WITH AN OVERHEAD CLEARANCE OF AT LEAST 13'-6" FOR STRUCTURES NOT EXCEEDING 30' IN HEIGHT AND SHALL PROVIDE ACCESS TO WITHIN 150' OF ALL EXTERIOR PORTIONS OF THE BUILDING. STRUCTURES EXCEEDING 30' IN HEIGHT SHALL BE PROVIDED WITH AN AERIAL APPARATUS ACCESS ROAD 26' IN WIDTH IN THE IMMEDIATE VICINITY OF THE BUILDING OR PORTION THEREOF AND SHALL PROVIDE AT LEAST ONE OF THE REQUIRED ACCESS ROADS TO BE LOCATED NOT LESS THAN 15' AND NOT MORE THAN 30' FROM THE STRUCTURE PARALLEL TO ONE ENTIRE SIDE OF THE STRUCTURE. NC FPC 2012 502.1,503.1.1, 503.2.1, D102.1 2.GRADE AND APPROACH; FIRE APPARATUS ACCESS ROADS SHALL NOT EXCEED 10% IN GRADE UNLESS APPROVED BY THE FIRE CHIEF AND ALL APPROACH AND DEPARTURE ANGLES SHALL BE WITHIN THE LIMITS ESTABLISHED BASED ON THE DEPARTMENT'S APPARATUS. NC FPC 2012, 503.2.7, 503.2.8 and D103.2 3.GATES AND BARRICADES; WHERE REQUIRED OR AUTHORIZED BY THE FIRE CODE OFFICIAL AND PERMANENT OR TEMPORARY CONSTRUCTION, ANY GATES ACROSS FIRE APPARATUS ACCESS ROADS SHALL BE A MINIMUM WIDTH OF 20 FEET, BE OF SWINGING OR SLIDING TYPE, HAVE AN EMERGENCY MEANS OF OPERATION, SHALL BE OPENABLE BY EITHER FORCIBLE ENTRY OR KEYED, CAPABLE OF BEING OPERATED BY ONE PERSON, AND SHALL BE INSTALLED AND MAINTAINED ACCORDING TO UL 325 and ASTM F 2200. NC FPC 2012, 503.5, 503.6, D103.5 4.FIRE LANES; WHERE REQUIRED, APPROVED MARKING SIGNS INCLUDING THE WORDS, NO PARKING-FIRE LANE SIGNS SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS. NC FPC 2012, 503.3, D103.6, D103.6.1, D103.6.2 5.PREMISE IDENTIFICATION; APPROVED BUILDING ADDRESS NUMBERS, PLACED IN ACCEPTABLE POSITION TO THE FIRE CODE OFFICIAL, SHALL BE REQUIRED ON ALL NEW BUILDINGS. NC FPC 2012, 505.1 6.KEY BOXES; WHERE REQUIRED BY THE FIRE CODE OFFICIAL, A SECURE KEY BOX, MOUNTED ON THE ADDRESS SIDE OF THE BUILDING, NEAR THE MAIN ENTRANCE, SHALL BE PROVIDED TO ENSURE ADEQUATE ACCESS TO THE BUILDING BASED ON LIFE SAFETY AND/OR FIRE PROTECTION NEEDS. NC FPC 2012, 506 7.FIRE HYDRANTS; THE FARTHEST HYDRANT SERVING A PROPOSED STRUCTURE MUST BE NO MORE THAN 500 FEET DISTANT. A MAXIMUM DISTANCE OF 500 FEET SPACING BETWEEN HYDRANTS MUST BE MAINTAINED UNLESS OTHERWISE APPROVED BY THE FIRE CODE OFFICIAL. LESSER SPACING DISTANCES MAY BE REQUIRED. A MINIMUM WORKING SPACE OF 3 FEET MUST BE MAINTAINED AROUND ALL HYDRANTS. WHERE HYDRANTS ARE SUBJECT TO PHYSICAL IMPACT, PHYSICAL PROTECTION MAY BE REQUIRED, NC FPC 2012, 507.5.6. THE MINIMUM NUMBER OF REQUIRED HYDRANTS AND THEIR SPACING MUST MEET NC FPC 2012, APPENDIX C, TABLE C 105.1 8.FIRE DEPARTMENT CONNECTIONS, LOCATIONS; ANY REQUIRED FDCS FOR ANY BUILDINGS SHALL MEET THE DESIGN AND INSTALLATION REQUIREMENTS FOR THE CURRENT, APPROVED EDITION OF NFPA 13, 13D, 13R, OR 14 OF THE NC FPC 2012 AND TOWN ORDINANCES; 7-38 FOR LOCATION. FDCS SHALL BE INSTALLED ON THE STREET/ ADDRESS SIDE OF THE BUILDING AND WITHIN 100' OF A HYDRANT OR UNLESS OTHERWISE APPROVED BY THE FIRE CODE OFFICIAL AND SHALL NOT BE OBSTRUCTED OR HINDERED BY PARKING OR LANDSCAPING. FDC'S SHALL BE EQUIPPED WITH NST. 9.FIRE DEPARTMENT CONNECTIONS, INSTALLATION; A WORKING SPACE OF NOT LESS THAN 36 INCHES IN WIDTH AND DEPTH AND A WORKING SPACE OF 78 INCHES IN HEIGHT SHALL BE PROVIDED ON ALL SIDES WITH THE EXCEPTION OF WALL MOUNTED FDC'S UNLESS OTHERWISE APPROVED BY THE FIRE CODE OFFICIAL. THE FDC'S WHERE REQUIRED MUST BE PHYSICALLY PROTECTED BY AN APPROVED BARRIER FROM IMPACTS. NC FPC 2012, 912.1, 912.2 912.2.1, 912.3.2, 312 FIRE DEPARTMENT NOTES PUBLIC UTILITIES ELECTRIC: DUKE ENERGY CAROLINAS DEVELOPMENT PLANNING ATTN: SHARONDA FRAZIER PHONE: 1-800-454-3853/MOBILE: (984) 364-7494 http://www.duke-energy.com/builders-developers/development-planning.asp GAS: TELEPHONE: ATTN: CABLE TV: ATTN: WATER/SEWER: CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CONTER DRIVE WILMINGTON, NC 28403 ATTN: JEFF THEBERGE (JEFF.THEBERGE@CFPUA.ORG) PHONE: 910-332-6550 TELEPHONE: ATTN:PHONE: BY NO . DA T E RE V I S I O N S LEGEND PROPERTY, LINE PROPERTY, CORNER FOUND PROPERTY, ADJOINING LINED LEGAL RIGHT-OF-WAY PROPERTY, CORNER FOUND (OTHERS) EXISTING PROPOSED PROPERTY, CONCRETE MONUMENT PROPERTY, LINE RESERVED BUILDING CHANNEL COMMUNICATION, MANHOLE COMMUNICATION, JUNCTION BOX COMMUNICATION, PANEL BOX COMMUNICATION, PEDESTAL COMMUNICATION, STUB OUT COMMUNICATION, UNDERGROUND COMMUNICATION, OVERHEAD COMMUNICATION, HANDHOLE COMMUNICATION, WITNESS POST CONTROL, GPS CONTROL, MAPPING CONTROL, REFERENCE CONTROL, TRAVERSE CURB CURB DEPRESSION EDGE OF PAVEMENT EDGE OF GRAVEL EASEMENT FENCE FIBER OPTIC, MANHOLE FIBER OPTIC, JUNCTION BOX FIBER OPTIC, PANEL BOX FIBER OPTIC, PEDESTAL FIBER OPTIC, UNDERGROUND FIBER OPTIC, OVERHEAD FIBER OPTIC, HANDHOLE FIBER OPTIC, WITNESS POST FLOODPLAIN GUIDE RAIL MARKING, HANDICAP PARKING NATURAL GAS, MANHOLE NATURAL GAS, WITNESS POST NATURAL GAS, UNDERGROUND NATURAL GAS, METER CONTROL, BENCHMARK PHONE, MANHOLE PHONE, JUNCTION BOX PHONE, PANEL BOX PHONE, PEDESTAL PHONE, UNDERGROUND PHONE, OVERHEAD PHONE, HANDHOLE PHONE, WITNESS POST POWER, HANDHOLE POWER, GUY WIRE POWER, JUNCTION BOX POWER, GUY POLE POWER, LIGHT POWER, MANHOLE POWER, OVERHEAD POWER, METER POWER, PANEL BOX POWER, PEDESTAL POWER, TRANSFORMER POWER, SPOT LIGHT POWER, UTILITY POLE POWER, WITNESS POST POWER, YARD LIGHT POWER, UNDERGROUND SITE, AIR CONDITIONER SITE, BOLLARD SITE, BORING LOCATION SITE, MONITOR WELL SITE, POST SITE, SIGN POST AND BOARD SITE, TRAFFIC SIGN DESCRIPTION SOIL BOUNDARY STREAM WaC SOIL LABEL SANITARY SEWER, MANHOLE SANITARY SEWER, FORCE MAIN MANHOLE SANITARY SEWER, UNDERGROUND (4" DIA TO 10" DIA) SANITARY SEWER, SEPTIC TANK SANITARY SEWER, VALVE SANITARY SEWER, FORCE MAIN SANITARY SEWER, LATERAL SANITARY SEWER, WITNESS POST STORM SEWER, MANHOLE STORM SEWER, INLET STORM SEWER,HEADWALL STORM SEWER, UNDERGROUND STORM SEWER, ROOF DRAIN LINE STORM SEWER, STAND PIPE STORM SEWER, CLEAN-OUT STORM SEWER, WITNESS POST SANITARY SEWER, CLEAN-OUT MINOR CONTOUR MAJOR CONTOUR SPOT ELEVATION 101 100 X 100.5 VEGETATION, SHRUB VEGETATION, GRASS LINE / LANDSCAPED AREA VEGETATION, DECIDUOUS SHOWING CANOPY VEGETATION, CONIFEROUS SHOWING CANOPY VEGETATION, TREE LINE WATER, FIRE HYDRANT WATER, IRRIGATION VALVE BOX WATER, MANHOLE WATER, METER WATER, POST INDICATOR VALVE WATER, SIAMESE CONNECTION WATER, UNDERGROUND WATER, VALVE WATER, WITNESS POST 101 100 LEGEND TO BE REMOVEDT.B.R. 100.5 LIMITS OF DISTURBANCE *STORM SEWER, DOWNSPOUT LOCATION NATURAL GAS VALVE EXISTING PROPOSED DESCRIPTION 4 5 4 4 444 6474 7 474 8 44 43 42 45 43 42 41 4 8 4 7 4 6 4 7 46 45 44 43 42 41 4 0 3 9 3 8 3 7 3 6 35 34 3 3 32 31 32 33 34 35 3 434 35 3 5 3 4 3 3 3 2 31 32 3334 3536 36 37 3 8 39 4 0 4 1 4 2 4 3 4 4 41 40 39 38 37 36 35 34 4444 4 5 4 6 4 8 MB Sign S 4 2 ° 3 1 ' 4 5 " W 15 7 . 0 9 ' S 50°36'13" E 535.84' N 0 9 ° 0 3 ' 4 8 " E 1 2 5 . 3 1 ' 15 7 . 1 5 ' ( R ) S 51°18'13" E 536.16'(R) N 0 8 ° 2 4 ' 0 7 " E 1 2 5 . 2 6 ' ( R ) N 45°18'27" W 466.61'(R) Ove r h e a d P o w e r GM Patio Area CO CO FH T T T MB 8 Spaces 7 S p a c e s 4 S p a c e s 2 S p 2 Spaces 4 Spaces 5 Sp a c e s 4 Sp a c e s 2 S p a c e s 2 S p 1 Sp 4 S p a c e s 12 Spaces S 4 2 ° 3 1 ' 4 5 " W 15 7 . 0 9 ' S 50°36'13" E 535.84' N 0 9 ° 0 3 ' 4 8 " E 1 2 5 . 3 1 ' N 44°36'43" W466.52' 1.505 Acres ± 65575.3 Sq. Feet ± S 51°18'13" E 536.16'(R) N 0 8 ° 2 4 ' 0 7 " E 1 2 5 . 2 6 ' ( R ) N 45°18'27" W 466.61'(R) D r a i n a g e P o n d Ove r h e a d P o w e r Two Story Brick-Veneer Building 6,675 Sqft± x26' High 54 . 7 ' 114.1' 12 . 4 ' 10.2' 42 . 3 ' 124.3' MA R K E T S T R E E T US H I G H W A Y # 1 7 B U S 10 0 ' R / W 8 OAK 24 OAK 8 OAK 8 OAK8 OAK 24 OAK (DBL) 18 OAK (DBL) 8 OAK 12 OAK 8 OAK 8 OAK 12 CMYRTLE 12 CMYRTLE 9 OAK 8 OAK 8 OAK 8 OAK 8 OAK 9 OAK 7 LIVE OAK 7 LIVE OAK 12 LIVE OAK8 LIVE OAK12 LIVE OAK 12 LIVE OAK 8 LIVE OAK 24 CMYRTLE 10 CMYRTLE 12 OAK 7 LIVE OAK9 LIVE OAK 8 OAK8 OAK 12 OAK 9 OAK 24 OAK (DBL) 15 LIVE OAK 8 CMYRTLE BUILDING HEIGHT 66.62'BUILDING HEIGHT 71.90' 12 LIVE OAK 10 OAK 8 LIVE OAK CMYRTLE CMYRTLE 8 PINE 8 PINE DBL OAK 18 10 CMYRTLE8 CMYRTLE 12 JAP MAPLE 15" CMP DI RIM= 45.63 INV (NW)= 39.59 INV (N)= 41.59 INV (SE)= 39.44 INV (S)= 41.45 48" C M P 48" CM P 1 5 " H D P E DI RIM= 42.47 INV (NW)= 36.56 INV (SE)= 36.39 MH RIM= 46.93 INV= 40.11 48" CMP 15" CMP 12" C M P 12 " C M P 15" C M P CI RIM= 40.43 INV (NW)= 35.66 INV (SE)= 34.95 INV= 34.61 RIM= 34.04 INV=31.84 INV= 31.63 INV= 32.59 4 8 " C M P E O I CI RIM= 43.47 INV= 40.84 DI RIM= 43.61 INV (NE)= 40.14 INV (SE)= 40.05 CI RIM= 42.43 INV (NW)= 38.83 INV (SE)= 38.53 CI RIM= 38.18 STRUCTURE FULL, CANNOT SEE PIPE SSMH RIM= 47.29 INV (IN)= 29.09 INV (OUT)= 28.39 10 " D I P EO I LP TANK TBM A ELEV= 45.17 TBM B ELEV= 39.77 GREASE TRAP CI RIM= 45.73 INV= 41.87 15 " C P P CI RIM= 45.62 INV= 42.25 1 5 " C P P CI RIM = 3 9 . 1 0 INV ( N W ) = 3 4 . 7 3 INV ( N E ) = 3 4 . 6 8 48 " R C P E O I E O I 48" CMP T O P O F B A N K TO P O F B A N K B O T T O M O F B A N K BOTTOM OF BANK TOP OF BANK BOTTOM OF BANK EVIRF EVIPF EVIRF EVIPF @1+08.3 1.13' Lt FOUND 2" IRON PIPE UNKNOWNFOUND IRON PIN BACK WATER FLOW VALVE PUMP HOUSE FOUND IRON PIPE FOUND IRON PIPE BENT COMPUTED POINT 10' WIDE WATER AND SEWER UTILITY EASEMENT; BK5255 PG445 30.00 2 0 . 0 0 APPROXIMATE DUKE ENERGY PROGRESS EASEMENTS PER DB6096; PG1312 U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C S 0 2 0 1 . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 3 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - NOT FOR CONSTRUCTION CS0201 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 01/18/2022 ESM SHEET APPROVED BY OF3 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 20'40' PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 N O R T H TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S EX I S T I N G C O N D I T I O N S P L A N 4 5 4 4 444 6474 7 474 8 44 43 42 45 43 42 41 4 8 4 7 4 6 4 7 46 45 44 43 42 41 4 0 3 9 3 8 3 7 3 6 35 34 3 3 32 31 32 33 34 35 3 434 35 3 5 3 4 3 3 3 2 31 32 3334 3536 36 37 3 8 39 4 0 4 1 4 2 4 3 4 4 41 40 39 38 37 36 35 34 4444 4 5 4 6 4 8 MB Sign S 4 2 ° 3 1 ' 4 5 " W 15 7 . 0 9 ' S 50°36'13" E 535.84' N 0 9 ° 0 3 ' 4 8 " E 1 2 5 . 3 1 ' 15 7 . 1 5 ' ( R ) S 51°18'13" E 536.16'(R) N 0 8 ° 2 4 ' 0 7 " E 1 2 5 . 2 6 ' ( R ) N 45°18'27" W 466.61'(R) Ove r h e a d P o w e r GM Patio Area CO CO FH T T T MB 8 Spaces 7 S p a c e s 4 S p a c e s 2 S p 2 Spaces 4 Spaces 5 Sp a c e s 4 Sp a c e s 2 S p a c e s 2 S p 1 Sp 4 S p a c e s 12 Spaces S 4 2 ° 3 1 ' 4 5 " W 15 7 . 0 9 ' S 50°36'13" E 535.84' N 0 9 ° 0 3 ' 4 8 " E 1 2 5 . 3 1 ' N 44°36'43" W466.52' 1.505 Acres ± 65575.3 Sq. Feet ± S 51°18'13" E 536.16'(R) N 0 8 ° 2 4 ' 0 7 " E 1 2 5 . 2 6 ' ( R ) N 45°18'27" W 466.61'(R) D r a i n a g e P o n d Ove r h e a d P o w e r Two Story Brick-Veneer Building 6,675 Sqft± x26' High 54 . 7 ' 114.1' 12 . 4 ' 10.2' 42 . 3 ' 124.3' MA R K E T S T R E E T US H I G H W A Y # 1 7 B U S 10 0 ' R / W 8 OAK 24 OAK 8 OAK 8 OAK8 OAK 24 OAK (DBL) 18 OAK (DBL) 8 OAK 12 OAK 8 OAK 8 OAK 12 CMYRTLE 12 CMYRTLE 9 OAK 8 OAK 8 OAK 8 OAK 8 OAK 9 OAK 7 LIVE OAK 7 LIVE OAK 12 LIVE OAK8 LIVE OAK12 LIVE OAK 12 LIVE OAK 8 LIVE OAK 24 CMYRTLE 10 CMYRTLE 12 OAK 7 LIVE OAK9 LIVE OAK 8 OAK8 OAK 12 OAK 9 OAK 24 OAK (DBL) 15 LIVE OAK 8 CMYRTLE BUILDING HEIGHT 66.62'BUILDING HEIGHT 71.90' 12 LIVE OAK 10 OAK 8 LIVE OAK CMYRTLE CMYRTLE 8 PINE 8 PINE DBL OAK 18 10 CMYRTLE8 CMYRTLE 12 JAP MAPLE 15" CMP DI RIM= 45.63 INV (NW)= 39.59 INV (N)= 41.59 INV (SE)= 39.44 INV (S)= 41.45 48" C M P 48" CM P 1 5 " H D P E DI RIM= 42.47 INV (NW)= 36.56 INV (SE)= 36.39 MH RIM= 46.93 INV= 40.11 48" CMP 15" CMP 12" C M P 12 " C M P 15" C M P CI RIM= 40.43 INV (NW)= 35.66 INV (SE)= 34.95 INV= 34.61 RIM= 34.04 INV=31.84 INV= 31.63 INV= 32.59 4 8 " C M P E O I CI RIM= 43.47 INV= 40.84 DI RIM= 43.61 INV (NE)= 40.14 INV (SE)= 40.05 CI RIM= 42.43 INV (NW)= 38.83 INV (SE)= 38.53 CI RIM= 38.18 STRUCTURE FULL, CANNOT SEE PIPE SSMH RIM= 47.29 INV (IN)= 29.09 INV (OUT)= 28.39 10 " D I P EO I LP TANK TBM A ELEV= 45.17 TBM B ELEV= 39.77 GREASE TRAP CI RIM= 45.73 INV= 41.87 15 " C P P CI RIM= 45.62 INV= 42.25 1 5 " C P P CI RIM = 3 9 . 1 0 INV ( N W ) = 3 4 . 7 3 INV ( N E ) = 3 4 . 6 8 48 " R C P E O I E O I 48" CMP EVIRF EVIPF EVIRF EVIPF @1+08.3 1.13' Lt FOUND 2" IRON PIPE UNKNOWNFOUND IRON PIN BACK WATER FLOW VALVE PUMP HOUSE FOUND IRON PIPE FOUND IRON PIPE BENT COMPUTED POINT 10' WIDE WATER AND SEWER UTILITY EASEMENT; BK5255 PG445 30.00 2 0 . 0 0 APPROXIMATE DUKE ENERGY PROGRESS EASEMENTS PER DB6096; PG1312 CURB TO BE CUT HERE, TBR CURB TO BE CUT HERE, TBR FACE AND BACK OF CURB TBR FACE AND BACK OF CURB TBR PATIO TBR SIDEWALK TBR SIDEWALK TBR FACE AND BACK OF CURB TBR PATIO TBR WALL TBR WALL TBR FENCE TBR STAIRS TBR STAIRS TBR BUILDING TBR CONCRETE PAVEMENT TBR CONCRETE PAVEMENT TBR FACE AND BACK OF CURB TBR FACE AND BACK OF CURB TBR U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C S 0 5 0 1 . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 4 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - NOT FOR CONSTRUCTION CS0501 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 01/18/2022 ESM SHEET APPROVED BY OF4 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 20'40' PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 N O R T H TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S DE M O L I T I O N P L A N MB S 4 2 ° 3 1 ' 4 5 " W 15 7 . 0 9 ' S 50°36'13" E 535.84' N 0 9 ° 0 3 ' 4 8 " E 1 2 5 . 3 1 ' 15 7 . 1 5 ' ( R ) S 51°18'13" E 536.16'(R) N 0 8 ° 2 4 ' 0 7 " E 1 2 5 . 2 6 ' ( R ) N 45°18'27" W 466.61'(R) FH MB S 4 2 ° 3 1 ' 4 5 " W 15 7 . 0 9 ' S 50°36'13" E 535.84' N 0 9 ° 0 3 ' 4 8 " E 1 2 5 . 3 1 ' N 44°36'43" W466.52' S 51°18'13" E 536.16'(R) N 0 8 ° 2 4 ' 0 7 " E 1 2 5 . 2 6 ' ( R ) N 45°18'27" W 466.61'(R) MA R K E T S T R E E T US H I G H W A Y # 1 7 B U S 10 0 ' R / W 8 LIVE OAK 8 PINE 8 PINE DBL OAK 18 T O P O F B A N K TO P O F B A N K B O T T O M O F B A N K BOTTOM OF BANK TOP OF BANK BOTTOM OF BANK EVIRF EVIPF EVIRF EVIPF @1+08.3 1.13' Lt FOUND 2" IRON PIPE UNKNOWNFOUND IRON PIN FOUND IRON PIPE FOUND IRON PIPE BENT COMPUTED POINT 10' WIDE WATER AND SEWER UTILITY EASEMENT; BK5255 PG445 30.00 2 0 . 0 0 APPROXIMATE DUKE ENERGY PROGRESS EASEMENTS PER DB6096; PG1312 18 . 0 0 ' 14 . 0 0 ' 10 . 0 0 ' 12.00' 3'R 3'R 24 . 0 0 ' 5.00'15.00' 8.50' 14 . 0 0 ' 14 . 0 0 ' 10'R 10'R 10'R 15'R 10'R 10 'R20'R 20'R 24 . 0 0 ' TAKE 5 CAR WASH EXPRESS 110' TUNNEL 50'R 8.50' 10'R 3' R 2 4'R 2 5 'R 5' R 5'R 1 0'R 3 'R 24'R 10'R 8'R 3'R 10'R 5'R 5'R 5'R 25 ' L A N D S C A P E S T R E E T Y A R D 2 5 ' B U I L D I N G S E T B A C K 25' BUILDING SETBACK 10' LANDSCAPE STRIP 25' BUILDING SETBACK 10' LANDSCAPE STRIP 75 ' B U I L D I N G A N D P A R K I N G S E T B A C K *2 5 % R E D U C T I O N U T I L I Z E D 25.00' 15.00' PROP. PROPERTY LINE (1.51 AC) PROP. CANOPY LIGHTS (SEE ARCHITECT PLANS) TRASH ENCLOSURE TO BE SCREENED PER 12.303. ENCLOSURE TO BE 75% OPAQUE. HEAVY DUTY CONCRETE PAVEMENT VAC 1 PROP. 5' X 2' TRUNCATED DOMES (SEE DETAIL 10.35B ON SHEET CS6001) PROP. CURB RAMP (SEE TYPE 1 MODIFIED DETAIL ON SHEET CS6001) PROP. 5' ADA CROSSWALK CAR WASH TUNNEL EXIT 7 DO NOT E N T E R PROP. STOP SIGN VAC 2 VAC 3 VAC 4 VAC 6VAC 5 VAC 7 VAC 8 VAC 9 VAC 10 VAC 11 HEAVY DUTY CONCRETE PAVEMENT HEAVY DUTY CONCRETE PAVEMENT DO NOT ENTER 2'R 10'R 8.00' 8.00' PROP. STOP SIGN PROP. STOP BAR TIE INTO EX. CURB AND GUTTER TIE INTO EX. CURB AND GUTTER PROP. BICYCLE PARKING (SEE DETAIL 50.20 ON CS6001) U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C S 1 0 0 1 . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 4 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - NOT FOR CONSTRUCTION CS1001 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 01/18/2022 ESM SHEET APPROVED BY OF5 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 20'40' PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 N O R T H TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S SI T E P L A N Ove r h e a d P o w e r FH T T T D r a i n a g e P o n d Ove r h e a d P o w e r MA R K E T S T R E E T US H I G H W A Y # 1 7 B U S 10 0 ' R / W 8 LIVE OAK 8 PINE 8 PINE DBL OAK 18 15" CMP DI RIM= 45.63 INV (NW)= 39.59 INV (N)= 41.59 INV (SE)= 39.44 INV (S)= 41.45 48" C M P 48" CM P DI RIM= 42.47 INV (NW)= 36.56 INV (SE)= 36.39 MH RIM= 46.93 INV= 40.11 48" CMP 15" C M P INV= 34.61 RIM= 34.04 INV=31.84 INV= 31.63 INV= 32.59 4 8 " C M P E O I CI RIM= 38.18 STRUCTURE FULL, CANNOT SEE PIPE CI RIM= 45.73 INV= 41.87 1 5 " C P P CI RIM = 3 9 . 1 0 INV ( N W ) = 3 4 . 7 3 INV ( N E ) = 3 4 . 6 8 E O I 48" CMP T O P O F B A N K TO P O F B A N K BO T T O M O F B A N K BOTTOM OF BANK TOP OF BANK BOTTOM OF BANK EVIRF EVIPF EVIRF EVIPF 10' WIDE WATER AND SEWER UTILITY EASEMENT; BK5255 PG445 30.00 2 0 . 0 0 APPROXIMATE DUKE ENERGY PROGRESS EASEMENTS PER DB6096; PG1312 45 4 4 444 6474 7 474 8 44 43 42 45 43 42 41 4 8 4 7 4 6 4 7 46 45 44 43 42 41 4 0 3 9 3 8 3 7 3 6 35 34 3 3 32 31 32 33 34 35 3 434 35 3 5 3 4 3 3 3 2 31 32 3334 3536 36 37 3 8 39 4 0 4 1 4 2 4 3 4 4 41 40 39 38 37 36 35 34 4444 4 5 4 6 4 8 TAKE 5 CAR WASH EXPRESS 110' TUNNEL PROP. PROPERTY LINE (1.51 AC) VAC 1 CAR WASH TUNNEL EXIT DO NOT E N T E R VAC 2 VAC 3 VAC 4 VAC 6VAC 5 VAC 7 VAC 8 VAC 9 VAC 10 VAC 11 DO NOT ENTER 4 5 46 40 41 41 4 1 42 4 3 42 43 44 45 4 24 3 44 45 44 44 41 44 46 41 4 4 44 44 43 42 42 43 41 4243 45 46 45 41 42 47 45 40 40 45 45 IN-1 MH-1 EX-DI IN-2 MH-2 IN-3 IN-5 IN-6 IN-8 IN-10 IN-12 YB-1 IN-11 IN-9 IN-7 CO-1CO-2CO-3CO-4 IN-4 PROP. ROOF DRAINS STORM SEWER STRUCTURE TABLE ID CO-1 CO-2 CO-3 CO-4 EX-DI IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 MH-1 MH-2 YB-1 RIM ELEVATION 44.13 43.34 42.67 42.24 44.83 45.46 46.14 43.38 43.58 43.81 43.41 44.07 42.39 43.65 40.73 39.76 39.25 45.43 45.44 40.43 INV IN (FROM) 42.43 (6" HDPE @ 1.00%) 42.15 (12" HDPE @ 0.50%) CO-1 42.15 (6" HDPE @ 4.58%) 41.58 (12" HDPE @ 0.96%) CO-2 41.58 (6" HDPE @ 12.05%) 41.15 (12" HDPE @ 1.00%) CO-3 39.54 (15" HDPE @ 0.86%) MH-1 40.63 (12" HDPE @ 0.81%) CO-4 40.49 (15" HDPE @ 0.67%) IN-3 39.79 (18" HECMP @ 1.00%) IN-4 39.49 (15" HDPE @ 1.16%) IN-5 38.46 (15" HDPE @ 1.06%) IN-6 38.36 (15" HDPE @ 0.86%) IN-7 37.04 (15" HDPE @ 0.96%) IN-8 37.04 (15" HDPE @ 1.00%) IN-9 36.11 (15" HDPE @ 1.00%) IN-10 36.11 (15" HDPE @ 1.00%) IN-11 39.77 (15" HDPE @ 6.57%) IN-1 41.06 (15" HDPE @ 1.00%) IN-2 35.76 (15" HDPE @ 1.00%) IN-12 INV OUT (TO) 42.33 (12" HDPE) CO-2 42.05 (12" HDPE) CO-3 41.48 (12" HDPE) CO-4 41.05 (12" HDPE) IN-3 41.00 (15" HDPE) MH-1 41.25 (15" HDPE) MH-2 40.53 (15" HDPE) IN-4 40.39 (18" HECMP) IN-5 39.69 (15" HDPE) IN-6 39.39 (15" HDPE) IN-8 38.41 (15" HDPE) IN-8 38.36 (15" HDPE) IN-10 37.13 (15" HDPE) IN-10 36.94 (15" HDPE) IN-12 36.77 (15" HDPE) IN-12 36.01 (15" HDPE) YB-1 39.67 (15" HDPE) EX-DI U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C S 1 5 0 1 . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 4 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - NOT FOR CONSTRUCTION CS1501 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 01/18/2022 ESM SHEET APPROVED BY OF6 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 20'40' PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 N O R T H TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S GR A D I N G P L A N 4 5 46 40 41 41 4 1 42 4 3 42 43 44 45 4 24 3 44 45 44 44 41 44 46 41 4 4 44 44 43 42 42 43 41 4243 45 46 45 41 42 47 45 40 40 45 45 4 5 4 4 444 6474 7 474 8 44 43 42 45 43 42 41 4 8 4 7 4 6 4 7 46 45 44 43 42 41 4 0 3 9 3 8 3 7 3 6 35 34 3 3 32 31 32 33 34 35 3 434 35 3 5 3 4 3 3 3 2 31 32 3334 3536 36 37 3 8 39 4 0 4 1 4 2 4 3 4 4 41 40 39 38 37 36 35 34 4444 4 5 4 6 4 8 FH T T T MA R K E T S T R E E T US H I G H W A Y # 1 7 B U S 10 0 ' R / W 8 LIVE OAK 8 PINE 8 PINE DBL OAK 18 SSMH RIM= 47.29 INV (IN)= 29.09 INV (OUT)= 28.39 10 " D I P EO I 10 " D I P GREASE TRAP T O P O F B A N K TO P O F B A N K BO T T O M O F B A N K BOTTOM OF BANK TOP OF BANK BOTTOM OF BANK EVIRF EVIPF EVIRF EVIPF 10' WIDE WATER AND SEWER UTILITY EASEMENT; BK5255 PG445 30.00 2 0 . 0 0 APPROXIMATE DUKE ENERGY PROGRESS EASEMENTS PER DB6096; PG1312 TAKE 5 CAR WASH EXPRESS 110' TUNNEL DO NOT E N T E R DO NOT ENTER PROP. ROOF DRAINS PROP. 45° BEND PROP. 2" SADDLE. SEE DETAIL W-3 ON SHEET CS6041 (CONTRACTOR TO VERIFY WATER MAIN LOCATION) PROP. 2" GATE VALVE PROP. 2" CURB STOP PROP. 18" DOMESTIC METER BOX W/ 2" METER PROP. 2" DOMESTIC PE PIPE PROP. 45° BEND PROP. REDUCE PRESSURE PRINCIPLE ASSEMBLY BFP (RPPA) PROP. 1.5" PE PIPE IRRIGATION LINE PROP. 1.5" SADDLE. SEE DETAIL W-3 ON SHEET CS6041 (CONTRACTOR TO VERIFY WATER MAIN LOCATION) PROP. 45° BEND IRRIGATION STUB OUT, SEE ARCHITECT PLANS FOR CONTINUATION CO 6" PVC SANITARY SEWER LATERAL SAMPLE WELL SEE PLUMBING PLANS 4 PURECLEAN UNDERGROUND WATER HOLDING TANKS SEE PLUMBING PLANS UNDERGROUND SEPARATOR TANK SEE PLUMBING PLANS SEE MEP PLANS FOR CONTINUATION SEE PLUMBING PLANS FOR CONTINUATION PROP. 18" IRRIGATION METER BOX W/ 1.5" METER PROP. UNDERGROUND COMMUNICATION LINE PROP. UNDERGROUND ELECTRIC PROP. 1.5" GATE VALVE PROP. 2" DOMESTIC PE PIPE PROP. 45° BEND PROP. 45° BEND CONTRACTOR TO VERIFY WATER MAIN LOCATION AND DEPTH U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C S 1 7 0 1 . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 4 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - NOT FOR CONSTRUCTION CS1701 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 01/18/2022 ESM SHEET APPROVED BY OF7 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 20'40' PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 N O R T H TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S UT I L I T Y P L A N 4 5 4 4 444 6474 7 474 8 44 43 42 45 43 42 41 4 8 4 7 4 6 4 7 46 45 44 43 42 41 4 0 3 9 3 8 3 7 3 6 3 5 34 3 3 32 31 32 33 34 35 3 434 35 3 5 3 4 3 3 3 2 31 32 3334 3536 36 37 3 8 39 4 0 4 1 4 2 4 3 4 4 41 40 39 38 37 36 35 34 4444 4 5 4 6 4 8 4 5 46 40 41 41 4 1 42 4 3 42 43 44 45 4 24 3 44 45 44 44 41 44 46 41 4 4 44 44 43 42 42 43 41 4243 45 46 45 41 42 47 45 40 40 45 45 TAKE 5 CAR WASH EXPRESS 110' TUNNEL 25 ' L A N D S C A P E S T R E E T Y A R D 2 5 ' B U I L D I N G S E T B A C K 25' BUILDING SETBACK 10' LANDSCAPE STRIP 25' BUILDING SETBACK 10' LANDSCAPE STRIP 75 ' B U I L D I N G A N D P A R K I N G S E T B A C K *2 5 % R E D U C T I O N U T I L I Z E D DO NOT E N T E R DO NOT ENTER PROP. ROOF DRAINS T T T T O P O F B A N K TO P O F B A N K B O T T O M O F B A N K BOTTOM OF BANK TOP OF BANK BOTTOM OF BANK 10' WIDE WATER AND SEWER UTILITY EASEMENT; BK5255 PG445 30.00 2 0 . 0 0 APPROXIMATE DUKE ENERGY PROGRESS EASEMENTS PER DB6096; PG1312 663 sf 1,064 sf 460 sf 2 - AR 6 - IV 4 - TO 2 - NS 1 - TO 4 - FG 3 - FG 9 - IC 2 - NS 4 - TO 3 - IV 2 - AR 1 - AR 2 - NS 1 - QF 5 - IO 2 - AR 5 - JC 1 - AR 7 - JC 3 - IV 3 - IV 8 - JC 3 - QF 4 - QF 9 - XH 1 - TO 15 - MC 10 - IC 8 - MC8 - IC MULCH (TYP)MULCH (TYP) MULCH (TYP) MULCH (TYP) TURF AREA 168-OJ 18 - MS 23 - MC 22 - MC 10 - MS 11 - MC 11 - JC 111-OJ 101-OJ 168-OJ 12 - MC 12 - IC 1 - FG 2 - NS U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C S 2 0 0 1 . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 5 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - NOT FOR CONSTRUCTION CS2001 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN HNW 01/10/2023 ESM SHEET APPROVED BY OF8 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 20'40' PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 N O R T H TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S LA N D S C P A I N G P L A N NEW HANOVER COUNTY: LANDSCAPE TABULATIONS: SITE AREA = 65,575 SF TABLE 5.4.5.B PERIMETER LANDSCAPE (10' MIN) (MINIMUM 1 EVERGREEN OR DECIDUOUS TREE EVERY 20 LINEAR FEET) SW BOUNDARY - 535.84 - 25 = 510.84 OR 511 / 20 = 25.5 OR 26 TREES REQUIRED 26 TREES PROVIDED NW BOUNDARY - 466.52 - 25 = 441.52 OR 442 / 20 = 22.1 OR 23 TREES REQUIRED 23 TREES PROVIDED TABLE 5.4.5.C PARKING LOT INTERIOR IMPERVIOUS PARKING PAVEMENT = 29,405 SF X 0.08 = 2,352 SF REQUIRED (8% OF ALL IMPERVIOUS AREAS)3,038 SF PROVIDED 1 TREE EACH ISLAND =4 TREES REQUIRED 4 TREES PROVIDED TABLE 5.4.6.B STREET YARD AREA STANDARDS (B-1 = 18 SF FOR EVERY LINEAR FOOT OF STREET YARD FRONTAGE) 157.09 X 18 = 2,827.62 / 600 = 4.71 OR 5 TREES REQUIRED 5 TREES PROVIDED SHRUBS = 6 X 5 =30 SHRUBS REQUIRED 30 SHRUBS PROVIDED TABLE 5.4.7 FOUNDATION PLANTINGS 132.03 X 22' HT = 2,904.6 X 0.12 =349 SF REQUIRED xxx SF PROVIDED NOTES: 1.ALL SHRUBS TO BE PLANTED IN MULCHED BEDS. 2.A 5' DIAMETER MULCH CIRCLE AROUND ALL TREES AND EVERGREENS. 3.FOUNDATION PLANTINGS TO BE IN A MULCH BED. 4.TURF TO BE IN ALL OTHER AREAS UNLESS OWNER DECIDES DIFFERENTLY. 5.GROUND COVERS TO BE PLANTED AS SPECIFIED. ROOT PRUNING SUPER SILT FENCE CHAIN LINKED FENCE TP TP TREE PROTECTION L.O.D.(limits of disturbance) LEGEND: TREE REMOVALX SAVED TREES 20 6 5 HA R O L D N. WH I T E , JR. NO R T H CARO L I N A L A N D SCA P E REGISTERED A R CHIT E C T SEE SHEET CS2002 FOR TREE INVENTORY SEE SHEET CS2003 FOR NOTES AND DETAILS INTERIOR LANDSCAPE Sign Patio Area CO CO FH T T T 8 Spaces 7 S p a c e s 4 S p a c e s 2 S p 2 Spaces 4 Spaces 5 Sp a c e s 4 Sp a c e s 2 S p a c e s 2 S p 1 Sp 4 S p a c e s 12 Spaces Two Story Brick-Veneer Building 6,675 Sqft± x26' High 54 . 7 ' 114.1' 12 . 4 ' 10.2' 42 . 3 ' 124.3' 10 0 ' R / W 8 OAK 24 OAK 8 OAK 8 OAK8 OAK 24 OAK (DBL) 18 OAK (DBL) 8 OAK 12 OAK 8 OAK 8 OAK 12 CMYRTLE 12 CMYRTLE 9 OAK 8 OAK 8 OAK 8 OAK 8 OAK 9 OAK 7 LIVE OAK 7 LIVE OAK 12 LIVE OAK8 LIVE OAK12 LIVE OAK 12 LIVE OAK 8 LIVE OAK 24 CMYRTLE 10 CMYRTLE 12 OAK 7 LIVE OAK9 LIVE OAK 8 OAK8 OAK 12 OAK 9 OAK 24 OAK (DBL) 15 LIVE OAK 8 CMYRTLE 12 LIVE OAK 10 OAK 8 LIVE OAK CMYRTLE CMYRTLE 8 PINE 8 PINE DBL OAK 18 10 CMYRTLE8 CMYRTLE 12 JAP MAPLE T O P O F B A N K TO P O F B A N K BO T T O M O F B A N K BOTTOM OF BANK TOP OF BANK BOTTOM OF BANK EVIRF EVIPF EVIRF EVIPF 10' WIDE WATER AND SEWER UTILITY EASEMENT; BK5255 PG445 30.00 2 0 . 0 0 APPROXIMATE DUKE ENERGY PROGRESS EASEMENTS PER DB6096; PG1312 U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C S 2 0 0 2 . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 5 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - NOT FOR CONSTRUCTION CS2002 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN HSW 01/18/2023 ESM SHEET APPROVED BY OF9 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 20'40' PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 N O R T H TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S EX I S T I N G T R E E P L A N 20 6 5 HA R O L D N. WH I T E , JR. NO R T H CARO L I N A L A N D SCA P E REGISTERED A R CHIT E C T 132" - 16" = 116" - (32x2) proposed = 52" x $200/tree = $10,400.00 12 3 4 1 7 65 25A 26 27 8 9 24 25 10 11 12 13 14 22 23 20 2118 191617 28 29 30 33 34 31 3236 35 40 37 38 39 42 41 44A 43 44 46 15 45 U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C S 2 0 0 3 . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 5 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - NOT FOR CONSTRUCTION CS2003 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN HSW 01/12/2023 ESM SHEET APPROVED BY OF10 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S LA N D S C A P I N G N O T E S A N D D E T A I L S 20 6 5 HA R O L D N. WH I T E , JR. NO R T H CARO L I N A L A N D SCA P E REGISTERED A R CHIT E C T SEE SHEET CS2001 FOR LANDSCAPE PLAN SEE SHEET CS2003 FOR TREE INVENTORY PRUNE & THIN DECIDUOUS SHRUBS UP TO 1/3 OF BRANCHES 12" 2"-3" TEMPORARY SAUCER BACKFILL SOIL PEDESTAL UNDISTURBED 1 8 DEPTH OF ROOT BALL ABOVE GRADE REMOVE ALL WIRE, PLASTIC, ROPE AND BURLAP (NATURAL AND SYNTHETIC) FROM TOP HALF OF ROOT BALL 2 '-3" MULCH LAYER (DO NOT PLACE MULCH ADJACENT TO BASE OF TRUNK) D=DIMENSION OF PLANT SPACING (SHRUB, GROUNDCOVER, ORNAMENTAL GRASS OR PERENNIAL) AS INDICATED ON PLANS OR PLANT SCHEDULE. PLAN VIEW MULCH 2" DEPTH MIN. SPECIFIED SOIL UNDISTURBED SUBGRADE/ EXISTING SOIL ED G E O F P L A N T I N G B E D "D" "D" "D" SPACING VARIES TREE PLANTING DETAIL3 6101 PLAN NOT TO SCALE U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ D E T A I L S . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 5 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - CS6001 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 01/18/2022 ESM SHEET APPROVED BY OF11 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S SI T E D E T A I L S 3' - 2 " MIN 12" DIA CONCRETE FOOTING 1" CROWN SCHEDULE 40 STEEL PIPE 6" DIAMETER- FILL POST WITH CONCRETE GRADE SURFACE 3' - 0 " 4' - 0 " 3" DOME BOLLARD DETAIL N.T.S. PENNONI TWO COATS OF ALKYD ENAMEL PAINT IN SAFETY YELLOW 6X6 WWM 6" X 6" SOURCE: PENNONI COMPACTED TO 95% PROCTOR 5%-7% AIR-ENTRAINED; 4,000 PSI (MIN.); CONCRETE; 6" THICK USE 8 FOOT CONTRACTION JOINT SPACING STANDARD DUTY CONCRETE PAVEMENT N.T.S. 6" STONE BASE NCDOT TYPE CABC PLAN HATCH BACKER ROD BOND BREAKER MATERIAL 1/2" FULL DEPTH 1/ 2 " 1/ 8 " 1/2" SECOND SAWCUT SILICONE JOINT SEALANT FIRST SAWCUT BACKER ROD BOND BREAKER MATERIAL 1/8" 1/ 2 " 1/ 8 " 1/2" 2" EXPANSION JOINTS CONTRACTION JOINTS 1/2" PREMOLDED JOINT FILLER BACKER ROD BOND BREAKER MATERIAL 1/ 2 " 1/ 8 " 1/2" CONSTRUCTION JOINTS SAWCUT SILICONE JOINT SEALANT STANDARD CONCRETE JOINTS N.T.S. 6X6 WWM 6" X 6" SOURCE: PENNONI COMPACTED TO 95% PROCTOR 5%-7% AIR-ENTRAINED; 4,000 PSI (MIN.); CONCRETE; 8" THICK USE 8 FOOT CONTRACTION JOINT SPACING HEAVY-DUTY CONCRETE PAVEMENT N.T.S. 6" STONE BASE NCDOT TYPE CABC PLAN HATCH NOTE: 1. #5 BAR DOWELS AT COLD JOINTS TYP. NOTE: 1. #5 BAR DOWELS AT COLD JOINTS TYP. SILICONE JOINT SEALANT U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ D E T A I L S . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 6 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - CS6021 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 03/14/2023 ESM SHEET APPROVED BY OF12 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S DR A I N A G E D E T A I L S U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ D E T A I L S . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 6 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - CS6041 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 01/18/2022 ESM SHEET APPROVED BY OF13 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S UT I L I T Y D E T A I L S -CONCRETE WASHOUT -SILT FENCE E&S LEGEND -TEMPORARY DIVERSION DIKE CB -CATCH BASIN INLET PROTECTION -COIR FIBER MAT -GEOTEXTILE FABRIC -CONSTRUCTION FENCE -RIP RAP -SILT FENCE OUTLET (SFO) Sign Patio Area CO CO FH T T T MA R K E T S T R E E T US H I G H W A Y # 1 7 B U S 10 0 ' R / W 8 OAK24 OAK 8 OAK 8 OAK8 OAK 24 OAK (DBL)18 OAK (DBL) 8 OAK 12 OAK 8 OAK8 OAK 12 CMYRTLE 12 CMYRTLE 9 OAK 8 OAK8 OAK 8 OAK 8 OAK 9 OAK 7 LIVE OAK 7 LIVE OAK 12 LIVE OAK8 LIVE OAK12 LIVE OAK12 LIVE OAK 8 LIVE OAK 24 CMYRTLE 10 CMYRTLE 12 OAK 7 LIVE OAK9 LIVE OAK 8 OAK8 OAK 12 OAK 9 OAK24 OAK (DBL) 15 LIVE OAK 8 CMYRTLE BUILDING HEIGHT 66.62' BUILDING HEIGHT 71.90' 12 LIVE OAK 10 OAK 8 LIVE OAK CMYRTLE CMYRTLE 8 PINE 8 PINE DBL OAK 18 10 CMYRTLE8 CMYRTLE 12 JAP MAPLE T O P O F B A N K TO P O F B A N K BO T T O M O F B A N K BOTTOM OF BANK TOP OF BANK BOTTOM OF BANK EVIRF EVIPF EVIRF EVIPF 10' WIDE WATER AND SEWER UTILITY EASEMENT; BK5255 PG445 30.00 20 . 0 0 APPROXIMATE DUKE ENERGY PROGRESS EASEMENTS PER DB6096; PG1312 4 5 4 4 444 6474 7 474 8 44 43 42 45 43 42 41 4 8 4 7 4 6 4 7 46 45 44 43 42 41 4 0 3 9 3 8 3 7 3 6 3 5 3433 32 31 32 33 34 35 3434 35 3 5 3 4 3 3 3 2 31 32 33343536 36 37 3 8 39 4 0 4 1 4 2 4 3 4 4 41 40 39 38 37 3635 34 444 4 4 5 4 6 4 8 PROP. LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE 1.28 AC 50.00' 12 . 0 0 ' REMOVE CURB AND GUTTER AS NEEDED TO INSTALL SILT AND CONSTRUCTION FENCE PROP. CONSTRUCTION ENTRANCE PER NCDEQ REQUIREMENTS PROP. CONCRETE WASHOUT PROP. TIRE WASH PROP. MATERIAL STOCKPILE AREA PROP. SILT FENCE PROP. CONSTRUCTION FENCE CB CB REMOVE CURB AND GUTTER AS NEEDED TO INSTALL DIVERSION DIKE TO SKIMMER BASINPROP. CHECK DAM PROP. CHECK DAM 42.60' 42.90' 43.50' PROP. 1.5" SKIMMER W/ 1.25" ORIFICE. INV. OUT: 40.30' 2" PIPE INV. OUT: 40.30'PROP. 12" SLOPE DRAIN INV. IN: 42.50' INSTALL TRM BETWEEN DISCHARGE AND SILT FENCEPROP. BAFFLES AT 16.5' SPACING EMERGENCY SPILLWAY W/ SLOPE STABILIZATION GEOTEXTILE PROP. 3' X 5' RIPRAP 2" PIPE INV. OUT: 40.30' 2.00' SID E S L O P E : 2 : 1 43.20' 41.44'42.36' 42.88' 43.20' SFO 41.00' 4142434444434241 41 42 43 44 4443 42 41 40 1. 0 0 ' B E R M SFO 39.90' 38.90' 41.00' U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C S 8 0 0 1 . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 6 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - NOT FOR CONSTRUCTION CS8001 BY NO . DA T E RE V I S I O N S DRVBR22040 1"=30' DTR 03/13/2023 ESM SHEET APPROVED BY OF14 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60' PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 N O R T H TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S ER O S I O N C O N T R O L P L A N P H 1 EROSION CONTROL NOTES: NO ACTIVITIES THAT EXPOSE SOILS SHALL COMMENCE PRIOR TO PRE-CONSTRUCTION MEETING WITH NEW HANOVER COUNTY. 1.ALL EROSION CONTROL MEASURES SHALL BE IN ACCORDANCE WITH THE NEW HANOVER COUNTY EROSION AND SEDIMENT CONTROL ORDINANCE. 2.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIRED BY A REPRESENTATIVE OF THE COUNTY ENGINEERING DEPARTMENT. 3.SLOPES SHALL BE GRADED NO STEEPER THAN 2:1. 2:1 FILL SLOPES GREATER THAN 10 FEET OF DEPTH REQUIRE ADDITIONAL TERRACING. 4.ALL PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES AND ALL SLOPES STEEPER THAN 3H:1V SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER AS SOON AS PRACTICABLE BUT IN ANY EVENT WITHIN 7 CALENDAR DAYS FROM THE LAST LAND DISTURBING ACTIVITY (TYP). 5.PERMANENT CUT AND FILL SLOPES PLACED ON A SUITABLE FOUNDATION SHOULD BE CONSTRUCTED AT 2:1 (HORIZONTAL TO VERTICAL) OR FLATTER. PERMANENT SLOPES OF 3:1 SHOULD BE CONSTRUCTED WHERE MOWING IS DESIRABLE AND AS INDICATED. IF FILL MATERIAL IS BROUGHT ONTO THE PROPERTY OR IF WASTE MATERIAL IS HAULED FROM THE PROPERTY, THEN THE CONTRACTOR SHALL DISCLOSE THE LOCATION OF ANY OFF-SITE BORROW LOCATION AND/OR WASTE BURIAL LOCATION TO THE EROSION CONTROL INSPECTOR. 6.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNER. 7.ALL EROSION CONTROL DEVICES SHALL REMAIN UNTIL SITE HAS BEEN PERMANENTLY STABILIZED. 8.ALL EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY STORM EVENT, BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY REPAIRS OR CLEANING NECESSARY TO MAINTAIN EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE COMPLETED IMMEDIATELY. 9.ALL SEEDED AREAS SHALL BE REFERTILIZED, RESEEDED AS NECESSARY, AND MULCHED ACCORDING TO THE SEEDING SCHEDULE. 10.OBTAIN GRADING/EROSION CONTROL PLAN APPROVAL FROM THE NEW HANOVER COUNTY ENGINEERING DEPARTMENT FOR THE EROSION CONTROL PLAN. 11.SET UP AN ON-SITE PRE-CONSTRUCTION MEETING WITH EROSION CONTROL INSPECTOR OF THE COUNTY ENGINEERING DEPARTMENT TO DISCUSS EROSION CONTROL MEASURES. 12.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE CLEARING LIMITS AND STAKE ALL TREES, AND STRUCTURES TO REMAIN AND BE PROTECTED. ALL BUFFERS SHALL BE CLEARLY DELINEATED IN THE FIELD TO BE PROTECTED. 13.INSTALL TEMPORARY CONSTRUCTION ENTRANCE AND SILT FENCE. TIRE WASH MAY BE REQUIRED IF CONSTRUCTION ENTRANCE IS NOT SUFFICIENT TO RETAIN SOIL. CONTRACTOR TO BLOCK ALL POSSIBLE ENTRANCES TO SITE BESIDES APPROVED CONSTRUCTION ENTRANCE W/ FENCING AND ORANGE BARRELS. 14.CONTRACTOR SHALL USE PROPOSED CONSTRUCTION ENTRANCE TO BUILD SKIMMER BASIN. THE CONTRACTOR SHALL CLEAR ONLY AS NECESSARY TO INSTALL THIS BASIN. 15.INSTALL SILT FENCE, INLET PROTECTION, SKIMMER BASIN, DIVERSION DITCHES, TREE PROTECTION, AND ANY OTHER MEASURES AS SHOWN ON PLANS, CLEARING ONLY AS NECESSARY TO INSTALL THESE DEVICES. 16.CALL FOR ON-SITE INSPECTION BY INSPECTOR. WHEN APPROVED, INSPECTOR ISSUES THE GRADING PERMIT AND CLEARING AND GRUBBING MAY BEGIN. THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL DEVICES AND STRUCTURES. 17.THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL DEVICES AND STRUCTURES. 18.GENERAL CONTRACTOR SHALL ENSURE THAT EROSION CONTROL MEASURES ARE IN PLACE AND FUNCTIONING PRIOR TO GRUBBING AND GRADING OPERATIONS. 19.BEGIN GRADING, INSTALLING ADDITIONAL EROSION CONTROL MEASURES AS INDICATED, AS REQUIRED, AND AS DEEMED NECESSARY BY THE EROSION CONTROL INSPECTOR. 20.FOR PHASED EROSION CONTROL PLANS, CONTRACTOR SHALL MEET WITH EROSION CONTROL INSPECTOR PRIOR TO COMMENCING WITH EACH PHASE OF EROSION CONTROL MEASURES. 21.STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDING IS NECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS AND ESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTION SEQUENCE. ALL SLOPES MUST BE SEEDED AND MULCHED WITHIN DAYS. REFER TO EROSION CONTROL ORDINANCE FOR ADDITIONAL REQUIREMENTS. 22.COORDINATE WITH EROSION CONTROL INSPECTOR PRIOR TO REMOVAL OF EROSION CONTROL MEASURES. 23.NO DEVICE SHALL BE REMOVED UNTIL SITE IS STABILIZED. 24.ALL EROSION CONTROL DEVICES SHOULD BE INSPECTED ONCE A WEEK AND AFTER EVERY RAINFALL EVENT OF 1" OR GREATER. IF ANY FAILURES ARE FOUND THEY SHOULD BE REPAIRED AS SOON AS POSSIBLE. 25.ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, U.S. DEPT. OF AGRICULTURE, NEW HANOVER COUNTY EROSION CONTROL ORDINANCE, AND THE NEW HANOVER LAND DEVELOPMENT STANDARDS. SEQUENCE OF CONSTRUCTION PHASE 1 1.OBTAIN ALL NECESSARY PLAN APPROVALS AND PERMITS PRIOR TO COMMENCING WORK. 2.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE CLEARING LIMITS AND STAKE ALL TREES, STRUCTURES AND ANY OTHER ITEMS TO REMAIN AND BE PROTECTED. 3.INSTALL TEMPORARY CONSTRUCTION ENTRANCES, SILT FENCE, SILT FENCE OUTLETS, AND TREE PROTECTION FENCE. 4.INSTALL SKIMMER BASIN, NECESSARY STORM DRAINAGE (FROM OUTLET STRUCTURES TO HEAD WALLS), TEMPORARY SILT DITCHES, AND ANY OTHER MEASURES AS SHOWN ON SHEET CS8001, CLEARING ONLY AS NECESSARY TO INSTALL THESE DEVICES AND STABILIZING EACH BASIN IMMEDIATELY AFTER INSTALLATION. 5.CONTRACTOR SHALL ENSURE THAT EROSION CONTROL MEASURES ARE IN PLACE AND FUNCTIONING PRIOR TO DEMOLITION, GRUBBING AND GRADING OPERATIONS. 6.CALL FOR ON-SITE INSPECTION BY INSPECTOR. WHEN APPROVED, INSPECTOR ISSUES THE GRADING PERMIT AND CLEARING, GRUBBING, DEMOLITION AND GRADING OF THE REMAINDER OF THE SITE MAY BEGIN. LIMITS OF DISTURBANCE: 1.28 AC. -CONCRETE WASHOUT -SILT FENCE E&S LEGEND -TEMPORARY DIVERSION DIKE CB -CATCH BASIN INLET PROTECTION -COIR FIBER MAT -GEOTEXTILE FABRIC -CONSTRUCTION FENCE -RIP RAP -SILT FENCE OUTLET (SFO) FH T T T MA R K E T S T R E E T US H I G H W A Y # 1 7 B U S 10 0 ' R / W 8 LIVE OAK 8 PINE 8 PINE DBL OAK 18 T O P O F B A N K TO P O F B A N K BO T T O M O F B A N K BOTTOM OF BANK TOP OF BANK BOTTOM OF BANK EVIRF EVIPF EVIRF EVIPF 10' WIDE WATER AND SEWER UTILITY EASEMENT; BK5255 PG445 30.00 20 . 0 0 APPROXIMATE DUKE ENERGY PROGRESS EASEMENTS PER DB6096; PG1312 4 5 4 4 444 6474 7 474 8 44 43 42 45 43 42 41 4 8 4 7 4 6 4 7 46 45 44 43 42 41 4 0 3 9 3 8 3 7 3 6 3 5 3433 32 31 32 33 34 35 3434 35 3 5 3 4 3 3 3 2 31 32 33343536 36 37 3 8 39 4 0 4 1 4 2 4 3 4 4 41 40 39 38 37 3635 34 444 4 4 5 4 6 4 8 PROP. LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE 1.28 AC IN-1 MH-1 EX-DI IN-2 MH-2 IN-3 IN-5 IN-6 IN-8 IN-10 IN-12 YB-1 IN-11 IN-9 IN-7 CO-1CO-2CO-3CO-4 IN-4 PROP. ROOF DRAINS DO NO T E N T E R DO NOT ENTER 4 5 46 40 41 41 4 1 42 4 3 42 4344 45 4 24 344 45 44 44 41 44 46 41 44 44 44 43 42 42 43 414243 45 46 45 41 42 47 45 40 40 45 45 REMOVE CURB AND GUTTER AS NEEDED TO INSTALL SILT AND CONSTRUCTION FENCE PROP. MATERIAL STOCKPILE AREA PROP. SILT FENCE PROP. CONSTRUCTION FENCE CB CB CB CBCB CBCBCBCB CB CB CB CB CB 50.00' 12 . 0 0 ' PROP. CONSTRUCTION ENTRANCE PER NCDEQ REQUIREMENTS PROP. CONCRETE WASHOUT PROP. TIRE WASH PROP. PH1 SKIMMER BASIN OUTLINE CB U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C S 8 0 0 2 . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 6 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - NOT FOR CONSTRUCTION CS8002 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 01/18/2022 ESM SHEET APPROVED BY OF15 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60' PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 N O R T H TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S ER O S I O N C O N T R O L P L A N P H 2 EROSION CONTROL NOTES: NO ACTIVITIES THAT EXPOSE SOILS SHALL COMMENCE PRIOR TO PRE-CONSTRUCTION MEETING WITH NEW HANOVER COUNTY. 1.ALL EROSION CONTROL MEASURES SHALL BE IN ACCORDANCE WITH THE NEW HANOVER COUNTY EROSION AND SEDIMENT CONTROL ORDINANCE. 2.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIRED BY A REPRESENTATIVE OF THE COUNTY ENGINEERING DEPARTMENT. 3.SLOPES SHALL BE GRADED NO STEEPER THAN 2:1. 2:1 FILL SLOPES GREATER THAN 10 FEET OF DEPTH REQUIRE ADDITIONAL TERRACING. 4.ALL PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES AND ALL SLOPES STEEPER THAN 3H:1V SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER AS SOON AS PRACTICABLE BUT IN ANY EVENT WITHIN 7 CALENDAR DAYS FROM THE LAST LAND DISTURBING ACTIVITY (TYP). 5.PERMANENT CUT AND FILL SLOPES PLACED ON A SUITABLE FOUNDATION SHOULD BE CONSTRUCTED AT 2:1 (HORIZONTAL TO VERTICAL) OR FLATTER. PERMANENT SLOPES OF 3:1 SHOULD BE CONSTRUCTED WHERE MOWING IS DESIRABLE AND AS INDICATED. IF FILL MATERIAL IS BROUGHT ONTO THE PROPERTY OR IF WASTE MATERIAL IS HAULED FROM THE PROPERTY, THEN THE CONTRACTOR SHALL DISCLOSE THE LOCATION OF ANY OFF-SITE BORROW LOCATION AND/OR WASTE BURIAL LOCATION TO THE EROSION CONTROL INSPECTOR. 6.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNER. 7.ALL EROSION CONTROL DEVICES SHALL REMAIN UNTIL SITE HAS BEEN PERMANENTLY STABILIZED. 8.ALL EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY STORM EVENT, BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY REPAIRS OR CLEANING NECESSARY TO MAINTAIN EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE COMPLETED IMMEDIATELY. 9.ALL SEEDED AREAS SHALL BE REFERTILIZED, RESEEDED AS NECESSARY, AND MULCHED ACCORDING TO THE SEEDING SCHEDULE. 10.OBTAIN GRADING/EROSION CONTROL PLAN APPROVAL FROM THE NEW HANOVER COUNTY ENGINEERING DEPARTMENT FOR THE EROSION CONTROL PLAN. 11.SET UP AN ON-SITE PRE-CONSTRUCTION MEETING WITH EROSION CONTROL INSPECTOR OF THE COUNTY ENGINEERING DEPARTMENT TO DISCUSS EROSION CONTROL MEASURES. 12.PRIOR TO ANY CLEARING OR INSTALLATION OF EROSION CONTROL DEVICES, CONTRACTOR SHALL STAKE CLEARING LIMITS AND STAKE ALL TREES, AND STRUCTURES TO REMAIN AND BE PROTECTED. ALL BUFFERS SHALL BE CLEARLY DELINEATED IN THE FIELD TO BE PROTECTED. 13.INSTALL TEMPORARY CONSTRUCTION ENTRANCE AND SILT FENCE. TIRE WASH MAY BE REQUIRED IF CONSTRUCTION ENTRANCE IS NOT SUFFICIENT TO RETAIN SOIL. CONTRACTOR TO BLOCK ALL POSSIBLE ENTRANCES TO SITE BESIDES APPROVED CONSTRUCTION ENTRANCE W/ FENCING AND ORANGE BARRELS. 14.CONTRACTOR SHALL USE PROPOSED CONSTRUCTION ENTRANCE TO BUILD SKIMMER BASIN. THE CONTRACTOR SHALL CLEAR ONLY AS NECESSARY TO INSTALL THIS BASIN. 15.INSTALL SILT FENCE, INLET PROTECTION, SKIMMER BASIN, DIVERSION DITCHES, TREE PROTECTION, AND ANY OTHER MEASURES AS SHOWN ON PLANS, CLEARING ONLY AS NECESSARY TO INSTALL THESE DEVICES. 16.CALL FOR ON-SITE INSPECTION BY INSPECTOR. WHEN APPROVED, INSPECTOR ISSUES THE GRADING PERMIT AND CLEARING AND GRUBBING MAY BEGIN. THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL DEVICES AND STRUCTURES. 17.THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL DEVICES AND STRUCTURES. 18.GENERAL CONTRACTOR SHALL ENSURE THAT EROSION CONTROL MEASURES ARE IN PLACE AND FUNCTIONING PRIOR TO GRUBBING AND GRADING OPERATIONS. 19.BEGIN GRADING, INSTALLING ADDITIONAL EROSION CONTROL MEASURES AS INDICATED, AS REQUIRED, AND AS DEEMED NECESSARY BY THE EROSION CONTROL INSPECTOR. 20.FOR PHASED EROSION CONTROL PLANS, CONTRACTOR SHALL MEET WITH EROSION CONTROL INSPECTOR PRIOR TO COMMENCING WITH EACH PHASE OF EROSION CONTROL MEASURES. 21.STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDING IS NECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS AND ESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTION SEQUENCE. ALL SLOPES MUST BE SEEDED AND MULCHED WITHIN DAYS. REFER TO EROSION CONTROL ORDINANCE FOR ADDITIONAL REQUIREMENTS. 22.COORDINATE WITH EROSION CONTROL INSPECTOR PRIOR TO REMOVAL OF EROSION CONTROL MEASURES. 23.NO DEVICE SHALL BE REMOVED UNTIL SITE IS STABILIZED. 24.ALL EROSION CONTROL DEVICES SHOULD BE INSPECTED ONCE A WEEK AND AFTER EVERY RAINFALL EVENT OF 1" OR GREATER. IF ANY FAILURES ARE FOUND THEY SHOULD BE REPAIRED AS SOON AS POSSIBLE. 25.25.ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, U.S. DEPT. OF AGRICULTURE, NEW HANOVER COUNTY EROSION CONTROL ORDINANCE, AND THE NEW HANOVER LAND DEVELOPMENT STANDARDS. SEQUENCE OF CONSTRUCTION PHASE 2 1.SPREAD TOP SOIL ON AREAS THAT HAVE ACHIEVED FINAL SUBGRADE. PERMANENTLY STABILIZE AREAS ONCE FINISH GRADE IS ACHIEVED. IMMEDIATELY FOLLOWING THE COMPLETION OF THE MOST RECENT LAND DISTURBING/GRADING ACTIVITY, TEMPORARILY STABILIZE THROUGHOUT CONSTRUCTION ANY DISTURBED AREAS, INCLUDING MATERIAL STOCKPILES THAT ARE SCHEDULED OR LIKELY TO REMAIN INACTIVE FOR 7 DAYS OR MORE, AND AS DEEMED NECESSARY BY THE EROSION CONTROL INSPECTOR. 2.THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL DEVICES AND STRUCTURES. 3.ALL TOPSOIL SHALL BE PLACED IN FILL SLOPES AREA WHEN POSSIBLE. 4.SKIMMER BASIN SHALL REMAIN THE SIZE AND SHAPE AS SHOWN ON SHEET CS8001 UNTIL PROPOSED STORM DRAINAGE, SHOWN ON THIS SHEET, HAS BEEN INSTALLED AND THE AREAS IDENTIFIED HAVE BEEN STABILIZED AND THE DENUDED AREAS HAVE BEEN REDUCED TO LESS THAN 1 AC. 5.AS CONSTRUCTION COMMENCES, THE CONTRACTOR SHALL ADJUST DIVERSION DITCHES, AS NECESSARY, AS SITE IS BROUGHT TO FINISHED GRADE. CONTRACTOR SHALL ALSO INSTALL ADDITIONAL EROSION CONTROL MEASURES (INLET PROTECTION, ETC.) AS SHOWN ON SHEETS CS8002 AND AS DEEMED NECESSARY BY THE EROSION CONTROL INSPECTOR. 6.STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDING IS NECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS AND ESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTION SEQUENCE. ALL SLOPES MUST BE SEEDED AND MULCHED WITHIN 5 CALENDAR DAYS. REFER TO THE NEW HANOVER COUNTY SEDIMENT AND EROSION CONTROL ORDINANCE FOR ADDITIONAL REQUIREMENTS. 7.ONCE AREAS IDENTIFIED ON SHEET CS8002 ARE COMPLETE, THESE AREAS HAVE BEEN ADEQUATELY STABILIZED, AND THE DENUDED AREAS DECREASED BELOW 1 AC, THE CONTRACTOR SHALL REQUEST APPROVAL FROM THE COUNTY INSPECTOR TO REMOVE THE SKIMMER BASIN, REMOVE ASSOCIATED TEMPORARY DIVERSION DIKES DIVERTING RUNOFF TO SKIMMER 1 AND CONVERT THE SKIMMER BASIN TO THE BMP'S TO COMPLETE THE FINAL LAND DEVELOPMENT WORK. 8.COORDINATE WITH EROSION CONTROL INSPECTOR PRIOR TO REMOVAL OF EROSION CONTROL MEASURES. 9.NO DEVICE SHALL BE REMOVED UNTIL SITE IS STABILIZED. 10.ALL EROSION CONTROL DEVICES SHOULD BE CHECKED PERIODICALLY AND AFTER EVERY MAJOR STORM EVENT. BUT IN NO CASE LESS THAN ONCE EVERY WEEK AND AFTER EVERY RAIN EVENT GREATER THAN 1.0" OF DEPTH. IF ANY FAILURES ARE FOUND, THEY SHOULD BE REPAIRED AS SOON AS POSSIBLE. 11.ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, U.S. DEPT. OF AGRICULTURE, NEW HANOVER COUNTY SEDIMENT AND EROSION CONTROL ORDINANCE, AND THE NEW HANOVER COUNTY LAND DEVELOPMENT STANDARDS MANUAL. LIMITS OF DISTURBANCE: 1.28 AC. U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ D E T A I L S . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 7 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - CS8501 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 01/18/2022 ESM SHEET APPROVED BY OF16 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S ER O S I O N C O N T R O L D E T A I L S U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ D E T A I L S . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 7 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - NOTES: 1.VERIFY WITH ENGINEER AND AUTHORITY HAVING JURISDICTION WHICH DISCHARGES FROM DEWATERING ACTIVITIES ARE ALLOWED OR ARE NOT ALLOWED NON-STORMWATER DISCHARGES UNDER THE GENERAL PERMIT AND OTHER REGULATIONS. OBTAIN ALL DEWATERING PERMITS AND AUTHORIZATIONS REQUIRED BY STATE AND LOCAL REGULATIONS. 2.GC MUST WAIT TO HAVE WRITTEN COPY OF ALL REQUIRED DEWATERING PERMITS AND AUTHORIZATIONS BEFORE PERFORMING DEWATERING ACTIVITIES. 3.DISCHARGES FROM DEWATERING OPERATIONS MUST BE DIRECTED THROUGH AN APPROPRIATE POLLUTION PREVENTION/TREATMENT SYSTEM OF CONTROL MEASURES, SUCH AS A SEDIMENT/FILTER BAG, SEDIMENT TRAP OR SEDIMENT BASIN, AND OTHERS, AS NEEDED, PRIOR TO BEING DISCHARGED FROM THE SITE OR INTO A WATER BODY OF THE STATE. UNDER NO CIRCUMSTANCES ARE DISCHARGES FROM DEWATERING OPERATIONS TO BE DISCHARGED DIRECTLY INTO SANITARY SEWER SYSTEMS, STREAMS, RIVERS, LAKES OR OTHER AREAS BEYOND THE PERMITTED PROJECT AREA. LIKEWISE, DISCHARGES INTO STORM SEWER SYSTEMS THAT DO NOT DRAIN TO A SUITABLE ON-SITE TREATMENT FACILITY, SUCH AS A BASIN, ARE ALSO PROHIBITED. DISCHARGES FROM DEWATERING OPERATIONS MUST ALSO BE CONDUCTED IN A MANNER SUFFICIENT TO PREVENT EROSION FROM THE DISCHARGE RUNOFF. 4.IN SEDIMENT TRAP OR BASIN OR POND DEWATERING OPERATIONS, WATER MUST ONLY BE REMOVED FROM THE SURFACE OF THE CONTAINED WATER. A SKIMMER OR SIMILAR FLOATING DEVICE MUST BE USED, TO ONLY REMOVE THE WATER AT THE SURFACE. 5.DO NOT DISCHARGE ON A SLOPE GREATER THAN THREE PERCENT NOR WITHIN 20 FEET OF A SURFACE WATER BODY. 6.DEWATERING SHALL NOT OCCUR DURING OR IMMEDIATELY AFTER PRECIPITATION EVENTS, BUT EXCEPTIONS SHALL BE EVALUATED ON CASE BY CASE BASIS. CONTACT THE ENGINEER AND AUTHORITY HAVING JURISDICTION NOTES: 1.ALL ON-SITE TOPSOIL MUST BE PRESERVED FOR REUSE ON THE SITE DURING REVEGETATION, UNLESS IT IS INFEASIBLE OR UNREASONABLE TO DO SO. (NOTE: TOPSOIL STOCKPILING ON-SITE MAY BE INFEASIBLE IF SPACE IS NOT AVAILABLE ON-SITE FOR TOPSOIL STOCKPILING OR IF LITTLE TO NO VEGETATION IS TO REMAIN UNDER POST-CONSTRUCTION CONDITIONS. ). 2.ALL SOIL STOCKPILES MUST BE STABILIZED TO PREVENT EROSION AND FUGITIVE DUST. THE SURFACE OF THE STOCKPILE MUST BE PROPERLY PROTECTED TO ELIMINATE THE RISK OF EROSION. SEE TEMPORARY SEEDING OR STABILIZATION DETAIL. SUITABLE ALTERNATIVE MEANS OF STABILIZATION CAN BE USED, SUCH AS PROPERLY ANCHORED PLASTIC TARPS. 3.PERIMETER SEDIMENT CONTROLS ALSO MUST BE INSTALLED AT STOCKPILE LOCATIONS TO PREVENT CONTACT WITH STORMWATER, INCLUDING RUN-ON. 4.STOCKPILES MUST BE LOCATED OUTSIDE OF ANY VEGETATED BUFFER AREAS AND SHOULD BE LOCATED AS FAR AS PRACTICABLE FROM STORMWATER CONVEYANCES AND IMPOUNDMENTS AND WATER BODIES. 5.STOCKPILE LOCATIONS SHALL BE NOTED ON THE SITE MAPS. NOTES: 1.LARGE AREAS OF SOIL THAT ARE DENUDED OF VEGETATION AND HAVE NO PROTECTION FROM PARTICLES BEING PICKED UP AND CARRIED BY WIND SHOULD BE PROTECTED WITH A TEMPORARY COVER OR KEPT UNDER CONTROL WITH WATER OR OTHER SOIL ADHERING PRODUCTS TO PREVENT SOIL PARTICLES FROM BECOMING AIRBORNE, AND FROM EXITING THE SITE PERIMETER. WATER TRUCKS OR OTHER DUST CONTROL AGENTS SHALL BE USED AS NEEDED DURING CONSTRUCTION TO MINIMIZE DUST GENERATED ON THE SITE. TACKIFIERS MAY BE USED TO HOLD SOIL IN PLACE AND PREVENT DUST. MANUFACTURER RECOMMENDATIONS FOR APPLICATION LOCATIONS AND RATES MUST BE USED FOR DUST CONTROL APPLICATIONS. 2.DUST CONTROL MUST BE PROVIDED BY THE GC TO A DEGREE THAT IS IN COMPLIANCE WITH APPLICABLE FEDERAL, LOCAL AND STATE DUST CONTROL REGULATIONS. 3.THE USE OF MOTOR OILS AND OTHER PETROLEUM BASED OR TOXIC LIQUIDS FOR DUST SUPPRESSION OPERATIONS IS PROHIBITED. 4.IN ADDITION TO BMPS, GC SHALL PERFORM PER PRACTICES AND PROCEDURES WHICH MINIMIZE AND PREVENT AIRBORNE DUST OR OTHER PARTICLES FROM OCCURRING. NOTES: 1.USING WATER FROM BASINS, TRAPS, TANKS, OR OTHER WATER CONTAINMENT AREAS FOR IRRIGATION MINIMIZES DISCHARGES FROM THE SITE, AND IT MAY SATISFY OTHER NEEDS OF THE CONSTRUCTION PROJECT, SUCH AS DUST CONTROL, VEGETATIVE ESTABLISHMENT, ETC. 2.CARE SHOULD BE TAKEN THAT WATER UTILIZED FROM CONTAINMENT AREAS ON-SITE FOR CONSTRUCTION PURPOSES DOES NOT DISCHARGE OFF-SITE. IF DISCHARGE IS ANTICIPATED OR OBSERVED, DEWATERING PROCEDURES STATED IN THE DEWATERING DETAIL MUST BE FOLLOWED. 3.GC SHALL IMPLEMENT IRRIGATION OR DISPERSION AS PRACTICABLE TO REDUCE WATER VOLUME IN IMPOUNDMENTS AND TO FOSTER VEGETATION GROWTH. NOTES: 1.STORM DRAIN INLET PROTECTION MEASURES SHALL PREVENT SOIL AND DEBRIS FROM ENTERING STORM DRAIN INLETS. 2.TEMPORARY CONTROLS SHALL BE CONSTRUCTED BEFORE THE SURROUNDING AREA IS DISTURBED. 3.TO PREVENT CLOGGING, STORM DRAIN CONTROL STRUCTURES MUST BE MAINTAINED FREQUENTLY. 4.CHECK ALL TEMPORARY CONTROL MEASURES DAILY, AND AFTER EACH STORM EVENT. 5.CONTROL MEASURES MUST BE BUILT PER DETAIL AND PLANS, AND MUST BE IN GOOD WORKING CONDITION AT ALL TIMES. NOTES: 1.MATERIAL STORAGE AREAS SHOULD BE LOCATED, WHEN POSSIBLE, TO MINIMIZE EXPOSURE TO WEATHER. INSPECTIONS SHALL EVALUATE DISTURBED AREAS AND AREAS USED FOR STORING MATERIALS THAT ARE EXPOSED TO RAINFALL FOR EVIDENCE OF, OR THE POTENTIAL FOR, POLLUTANTS ENTERING THE DRAINAGE SYSTEM OR DISCHARGING FROM THE SITE. IF NECESSARY, THE MATERIALS MUST BE COVERED OR ORIGINAL COVERS MUST BE REPAIRED OR SUPPLEMENTED. ALSO, PROTECTIVE BERMS MUST BE CONSTRUCTED, IF NEEDED, TO CONTAIN RUNOFF FROM MATERIAL STORAGE AREAS. GC SHALL ADHERE TO ALL STATE AND LOCAL REGULATIONS PERTAINING TO MATERIAL STORAGE AREAS. 2.CHEMICALS, PAINTS, SOLVENTS, FERTILIZERS, AND OTHER TOXIC MATERIALS MUST BE STORED IN WATERPROOF CONTAINERS. EXCEPT DURING APPLICATION, THE CONTAINERS AND THE CONTENTS MUST BE KEPT IN TRUCKS OR INSIDE OF STORAGE FACILITIES. RUNOFF CONTAINING SUCH MATERIAL MUST BE COLLECTED, REMOVED FROM THE SITE, TREATED, AND DISPOSED OF AT AN APPROVED SOLID WASTE AND CHEMICAL DISPOSAL FACILITY. NOTES: 1.ALL PERSONNEL INVOLVED WITH CONSTRUCTION ACTIVITIES MUST COMPLY WITH STATE AND LOCAL SANITARY OR SEPTIC SYSTEM REGULATIONS. PORTABLE TOILETS MUST BE LOCATED AT LEAST 30 FEET FROM INLETS, CHANNELS, SWALES, OR PERMITTED LIMITS OF DISTURBANCE, AND MUST BE LOCATED AT LEAST 50 FEET FROM WATERS OF THE STATE, OR WATERS OF THE U.S.. PORTABLE TOILETS MUST BE SECURELY ANCHORED AND/OR TIED DOWN. SECONDARY CONTAINMENT SHALL BE PROVIDED AND FULL CAPACITY SHALL BE RESTORED IMMEDIATELY UPON DISCOVERY OF ITS DIMINISHMENT. THE LOCATION OF SANITARY FACILITIES SHALL BE SHOWN ON THE SITE MAPS. NOTES: 1.SUBSTANCES THAT HAVE THE POTENTIAL FOR POLLUTING SURFACE AND/OR GROUNDWATER MUST BE CONTROLLED BY ANY MEANS NECESSARY TO ENSURE THAT THOSE DO NOT DISCHARGE FROM THE SITE. IN THIS REGARD, POTENTIALLY POLLUTING SUBSTANCES SHALL BE STORED AND HANDLED IN A MANNER CONSISTENT WITH THE RISK OF IMPACT THOSE REPRESENT, AND ACCORDING WITH THE REGULATIONS. 2.NO SOLID MATERIALS, INCLUDING BUILDING MATERIALS, ARE ALLOWED TO BE DISCHARGED FROM THE SITE WITH STORMWATER. ALL SOLID WASTE, INCLUDING DISPOSABLE MATERIALS INCIDENTAL TO THE CONSTRUCTION ACTIVITIES, MUST BE COLLECTED AND PLACED IN CONTAINERS. RUBBISH, TRASH, GARBAGE, LITTER, OR OTHER SUCH MATERIALS SHALL BE DEPOSITED INTO SEALED CONTAINERS. MATERIALS SHALL BE PREVENTED FROM LEAVING THE PREMISES THROUGH THE ACTION OF WIND OR STORMWATER DISCHARGE INTO DRAINAGE DITCHES OR WATERS OF THE STATE. THE CONTAINERS SHALL BE HAULED AWAY FROM THE SITE AND EMPTIED WHEN THOSE BECOME 95% FULL, OR AS NECESSARY, BY A CERTIFIED TRASH DISPOSAL SERVICE. LIDS OR COVERS FOR THE CONTAINERS SHALL BE PROVIDED FOR USE DURING RAIN EVENTS TO PREVENT WASTE CONTACT WITH STORMWATER. WASTES THAT CANNOT BE STORED IN A CONTAINER MUST BE STORED UNDER COVER OR INDOORS. THE LOCATION OF SOLID WASTE RECEPTACLES SHALL BE SHOWN ON THE SITE MAPS. NOTES: 1.CONTRACTOR SHALL PROVIDE DESIGNATED LOCATION FOR SORTING AND SEPARATING HAZARDOUS WASTES. 2.HAZARDOUS WASTE STORAGE MUST BE PROTECTED FROM WEATHER ELEMENTS AND HAVE RESTRICTED ACCESS. 3.HAZARDOUS WASTE STORAGE MUST COMPLY WITH LOCAL, STATE, AND FEDERAL REGULATIONS. 4.HAZARDOUS WASTE STORAGE MUST COMPLY WITH CONTRACT DOCUMENTS. NOTES: 1.CONCRETE WASTE MANAGEMENT PERTAINS TO WASTE FROM CONCRETE READY-MIX TRUCKS, MASONRY OPERATIONS, AND SIMILAR WASTE. 2.DISCHARGE OF EXCESS OR WASTE CONCRETE AND/OR WASH WATER FROM CONCRETE TRUCKS IS ALLOWED AT THE CONSTRUCTION SITE. ONLY COMMERCIALLY AVAILABLE ABOVE GROUND PORTABLE CONCRETE WASHOUT CONTAINERS ARE ALLOWED AND MUST BE PROTECTED FROM VEHICLE TRAFFIC AND CLEARLY IDENTIFIED BY LEGIBLE SIGNAGE, AND MUST BE LOCATED OUTSIDE OF VEGETATED BUFFERS AND AS FAR AS PRACTICABLE FROM STORMWATER CONVEYANCES AND IMPOUNDMENTS AND WATER BODIES. PORTABLE CONCRETE WASHOUT CONTAINERS SHALL CONTAIN AND/OR ACTIVELY MANAGE BOTH, SOLID AND FLUID, COMPONENTS OF THE MIX. CONCRETE WASHOUT CONTAINERS MUST BE CLEANED OR EXCHANGED WHEN THE REMAINING VOLUME IS REDUCED BY 85% TO PREVENT ANY POTENTIAL OVERFLOW IN A STORM EVENT. 3.ALTERNATIVELY, WASTE CONCRETE CAN BE PLACED INTO FORMS TO MAKE RIP RAP AND/OR OTHER USEFUL CONCRETE PRODUCTS. PORTABLE CONCRETE WASHOUT CONTAINERS SHALL BE DISPOSED IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL REGULATIONS. THE GC IS RESPONSIBLE FOR ASSURING THAT THESE PROCEDURES, APPLICABLE LAWS, AND ENVIRONMENTAL REGULATIONS ARE FOLLOWED. THE LOCATION OF CONCRETE WASHOUT CONTAINERS SHALL BE SHOWN ON THE SITE MAPS. DEWATERING STOCKPILES DUST CONTROL IRRIGATION OR DISPERSION INLET PROTECTION SOLID WASTE DISPOSAL CEMENT AND CONCRETE WASHOUT HAZARDOUS WASTE DISPOSAL SANITARY FACILITIES MATERIAL LAYDOWN AND STORAGE AREA NOTES: 1.THE GC SHALL IDENTIFY MASONS' AREA WITH LEGIBLE SIGNAGE ON THE SITE. TO THE EXTENT PRACTICAL, ALL MASONRY TOOLS, MATERIAL, INCLUDING SAND AND SACKED CEMENT AND/OR MORTAR MATERIALS, MIX, AND EQUIPMENT SHALL BE LOCATED WITHIN THE AREA IDENTIFIED. MATERIALS VULNERABLE TO WEATHER ELEMENTS SHALL BE STORED IN CONTAINERS AT THE END OF EACH WORK DAY; SUCH MATERIALS SHALL REMAIN STORED IN CONTAINERS WHEN NOT IN USE. 2.RUNOFF CONTROL, SUCH AS DIVERSION BERMS, SILT FENCE, SILT DIKE, OR OTHER MEANS OF CONTAINMENT SHALL BE PROVIDED TO PREVENT THE MIGRATION OF STORMWATER POLLUTANTS FROM THE MASONS' AREA. COVERED RECEPTACLES FOR DEBRIS AND TRASH DISPOSAL SHALL ALSO BE PROVIDED. 3.THE MASONS' AREA SHALL MEET OSHA AND OTHER REGULATORY REQUIREMENTS FOR PERSONAL PROTECTIVE EQUIPMENT (PPE), FIRE EXTINGUISHERS, ETC. GC SHALL PROVIDE SCREENING OR OTHER TECHNOLOGIES FOR MASONS' AREA TO PREVENT AIRBORNE TRANSPORT OF CEMENT DUST AND OTHER PARTICULATES DUE TO HIGH SPEED WIND OR OTHER CONDITIONS. THE LOCATION OF THE MASONS' AREA SHALL BE SHOWN ON THE SITE MAPS. MASONS' AREA NOTES: 1.CONSIDERATION MUST BE GIVEN TO ANTICIPATED CLIMATE AND SEASONAL CONDITIONS WHEN PLANTING SEED. 2.SEED SHALL BE FREE OF WEEDY SPECIES AND APPROPRIATE FOR SITE SOILS AND REGIONAL CLIMATE. SEED AND MULCH PER THE CONSTRUCTION DRAWINGS IMMEDIATELY AFTER TOPSOIL IS APPLIED AND FINAL GRADE IS REACHED. 3.THE SITE HAS ACHIEVED FINAL STABILIZATION ONCE ALL AREAS ARE COVERED WITH BUILDING FOUNDATION OR PAVEMENT, OTHER LANDSCAPING COVER (STONE, MULCH, ETC.), OR HAVE A STAND OF GRASS WITH A MINIMUM OF 80 PERCENT DENSITY OVER THE ENTIRE VEGETATED AREA, OR GREATER IN ACCORDANCE WITH THE GENERAL PERMIT REQUIREMENTS. 4.VEGETATED AREAS MUST BE WATERED, FERTILIZED, AND RESEEDED AS NEEDED TO ACHIEVE THIS REQUIREMENT. 5.THE VEGETATIVE DENSITY MUST BE MAINTAINED THROUGH PROJECT COMPLETION TO BE CONSIDERED STABILIZED. AREAS PROTECTED BY EROSION CONTROL BLANKETS ARE NOT PERMANENTLY STABILIZED UNTIL THE APPLICABLE GENERAL PERMIT REQUIREMENT FOR FINAL VEGETATIVE DENSITY IS ACHIEVED. 6.RIP-RAP, MULCH, GRAVEL, DECOMPOSED GRANITE OR OTHER EQUIVALENT PERMANENT STABILIZATION MEASURES MAY BE EMPLOYED IN LIEU OF VEGETATION BASED ON SITE-SPECIFIC CONDITIONS, DESIGN AND GOVERNING AUTHORITY APPROVAL. 7.ALL VEGETATED AREAS SHALL BE INSPECTED REGULARLY TO CONFIRM THAT A HEALTHY STAND OF GRASS IS MAINTAINED. SEEDING/VEGETATION REQUIREMENTS NOTES: 1.THE GC IS REQUIRED TO, AT A MINIMUM, INITIATE SOIL STABILIZATION MEASURES IMMEDIATELY WHENEVER ANY CLEARING, GRADING, EXCAVATING OR OTHER EARTH DISTURBING ACTIVITIES HAVE PERMANENTLY CEASED ON ANY PORTION OF THE SITE, OR TEMPORARILY CEASED ON ANY PORTION OF THE SITE . 2.ALL PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES AND ALL SLOPES STEEPER THAN 3 HORIZONTAL TO 1 VERTICAL (3:1) SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER (SUCH AS THE USE OF FAST-GERMINATING ANNUAL GRASS/GRAIN VARIETIES, STRAW/HAY MULCH, WOOD CELLULOSE FIBERS, TACKIFIERS, NETTING AND/OR BLANKETS) AS SOON AS PRACTICABLE BUT IN ANY EVENT WITHIN 7 CALENDAR DAYS FROM THE LAST LAND-DISTURBING ACTIVITY. (PER NC GENERAL PERMIT - NCG 010000) 3.ALL OTHER DISTURBED AREAS SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER (SUCH AS THE USE OF FAST-GERMINATING ANNUAL GRASS/GRAIN VARIETIES, STRAW/HAY MULCH, WOOD CELLULOSE FIBERS, TACKIFIERS, NETTING AND/OR BLANKETS) AS SOON AS PRACTICABLE BUT IN ANY EVENT WITHIN 21 CALENDAR DAYS FROM THE LAST LAND-DISTURBING ACTIVITY.(PER NCDEQ SECTION 6.01 OF PRACTICE STANDARDS AND SPECIFIACTIONS) 4.THE GC HAS 21 DAYS FROM INITIATION OF STABILIZATION TO COMPLETE SOIL PREPARATION, SEEDING, MULCHING, AND ANY OTHER REQUIRED ACTIVITIES RELATED TO THE PLANTING AND ESTABLISHMENT OF VEGETATION. THE GC ALSO HAS 7 DAYS FROM INITIATION OF STABILIZATION TO COMPLETELY INSTALL NON-VEGETATED MEASURES, IF UTILIZED. 5.ALL DISTURBED AREAS MUST BE STABILIZED TEMPORARILY WITH THE USE OF FAST-GERMINATING ANNUAL GRASS/GRAIN VARIETIES APPROPRIATE FOR SITE SOIL AND CLIMATE CONDITIONS. MULCH IS REQUIRED FOR ALL SEEDING APPLICATIONS, AND ALL MULCH APPLICATIONS MUST INCLUDE A SUITABLE FORM OF MULCH ANCHORING TO MINIMIZE MOVEMENT OF MULCH BY WIND OR WATER. 6.ALTERNATIVE STABILIZATION MEASURES TO SEEDING, SUCH AS ANCHORED MULCH APPLICATION (WITHOUT SEEDING), MAY BE UTILIZED DURING PERIODS WHEN VEGETATIVE GROWTH IS UNLIKELY (E.G. WINTER MONTHS). 7.IT IS NOT ACCEPTABLE TO ALLOW BARE SOIL TO REMAIN EXPOSED AT ANY TIME DURING THE YEAR, REGARDLESS OF WEATHER/TEMPERATURE/SITE CONDITIONS. 8.ALTERNATIVE STABILIZATION MEASURES INCLUDE, BUT ARE NOT LIMITED TO: ANCHORED STRAW/HAY MULCH, WOOD CELLULOSE FIBER MULCH, SPRAY-ON SOIL GLUES/BINDERS, AND ROLLED EROSION CONTROL PRODUCTS. 9.ALL ROLLED EROSION CONTROL PRODUCTS SHALL HAVE CURRENT QDOR(TM) STATUS ISSUED BY THE EROSION CONTROL TECHNOLOGY COUNCIL (ECTC) PLUS ANY STATE OR AGENCY-SPECIFIC REQUIREMENTS. EVIDENCE OF QDOR(TM) APPROVAL SHALL ACCOMPANY THE PRODUCT SHIPPED TO THE JOBSITE FOR READY IDENTIFICATION BY THE CONTRACTOR OR AGENCY INSPECTOR. 10.ROLLED EROSION CONTROL PRODUCTS (NETS, BLANKETS, TURF REINFORCED MATS) AND VEGETATED AREAS NOT MEETING REQUIRED VEGETATIVE DENSITIES FOR FINAL STABILIZATION MUST BE INSPECTED DAILY. RILING, RUTTING AND OTHER SIGNS OF EROSION INDICATE THE SPECIFIED EROSION CONTROL DEVICE IS NOT FUNCTIONING OR INSTALLED PROPERLY AND/OR ADDITIONAL EROSION CONTROL DEVICES ARE WARRANTED. NOTES: 1.PERMANENT STABILIZATION SHALL BE ACCOMPLISHED IN ALL DISTURBED AREAS BY COVERING THE SOIL WITH PAVEMENT, BUILDING STRUCTURES, VEGETATION, OR OTHER FORMS OF SOIL STABILIZATION. 2.THE GC IS REQUIRED TO INITIATE PERMANENT SOIL STABILIZATION MEASURES IMMEDIATELY UPON REACHING FINAL GRADE. 3.ALL PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES AND ALL SLOPES STEEPER THAN 3 HORIZONTAL TO 1 VERTICAL (3:1) SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER (SUCH AS THE USE OF FAST-GERMINATING ANNUAL GRASS/GRAIN VARIETIES, STRAW/HAY MULCH, WOOD CELLULOSE FIBERS, TACKIFIERS, NETTING AND/OR BLANKETS) AS SOON AS PRACTICABLE BUT IN ANY EVENT WITHIN 7 CALENDAR DAYS FROM THE LAST LAND-DISTURBING ACTIVITY. (PER NC GENERAL PERMIT - NCG 010000) 4.ALL OTHER DISTURBED AREAS SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER (SUCH AS THE USE OF FAST-GERMINATING ANNUAL GRASS/GRAIN VARIETIES, STRAW/HAY MULCH, WOOD CELLULOSE FIBERS, TACKIFIERS, NETTING AND/OR BLANKETS) AS SOON AS PRACTICABLE BUT IN ANY EVENT WITHIN 14 CALENDAR DAYS FROM THE LAST LAND-DISTURBING ACTIVITY.(PER NCDEQ SECTION 6.01 OF PROCTICE STANDARDS AND SPECIFICATIONS) 5.THE GC HAS 21 DAYS FROM INITIATION OF STABILIZATION TO COMPLETE SOIL PREPARATION, SEEDING, MULCHING, AND ANY OTHER REQUIRED ACTIVITIES RELATED TO THE PLANTING AND ESTABLISHMENT OF VEGETATION. THE GC ALSO HAS 7 DAYS FROM INITIATION OF STABILIZATION TO COMPLETELY INSTALL NON-VEGETATED MEASURES, IF UTILIZED. SOILS MUST BE PREPARED BEFORE INSTALLATION OF SOD OR SEED. 6.AT THE COMPLETION OF GROUND-DISTURBING ACTIVITIES, THE ENTIRE SITE MUST HAVE PERMANENT VEGETATIVE COVER MEETING VEGETATIVE DENSITY REQUIREMENTS IN THE GENERAL PERMIT, OR MULCH PER LANDSCAPE PLAN, IN ALL AREAS NOT COVERED BY HARDSCAPE (STONE, PAVEMENT, BUILDINGS, ETC.). 7.SEEDED AREAS SHALL BE PROTECTED WITH STRAW MULCH, HYDRAULIC MULCH OR A ROLLED EROSION CONTROL PRODUCT. STRAW MULCH MUST BE TACKIFIED OR CRIMPED BY DISC OR OTHER MACHINERY, AND ROLLED EROSION CONTROL PRODUCTS MUST BE INSTALLED PER MANUFACTURER RECOMMENDATIONS. ONLY ROLLED EROSION CONTROL PRODUCTS ARE PERMITTED TO BE USED IN FLOW CONVEYANCES. 8.ALL AREAS TO BE SEEDED MUST MEET TOPSOIL DEPTH, PH AND ORGANIC CONTENT REQUIREMENTS. 9.FINAL SITE STABILIZATION IS ACHIEVED WHEN PERENNIAL VEGETATIVE COVER PROVIDES PERMANENT STABILIZATION WITH A UNIFORM DENSITY GREATER THAN 80 PERCENT OVER THE ENTIRE AREA TO BE STABILIZED BY VEGETATIVE COVER. THIS AREA IS EXCLUSIVE OF AREAS THAT ARE COVERED WITH ROCK (CRUSHED GRANITE, GRAVEL, ETC.) OR LANDSCAPE MULCH, PAVED OR HAVE A BUILDING OR OTHER PERMANENT STRUCTURE ON THEM. 10.PRIOR TO PLACEMENT OF ORDER AND INSTALLATION, CONTRACTOR SHALL SUBMIT TO THE OWNER AND ENGINEER OF RECORD FOR APPROVAL THE SOD AND SEED MIX PROPOSED (INCLUDING SEEDING RATE) FOR INSTALLATION. TEMPORARY SEEDING OR STABILIZATION PERMANENT SEEDING, SOD OR MULCHING TEMPORARY STOCKPILE DETAIL NOT TO SCALE U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ D E T A I L S . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 7 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - CS8502 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 01/18/2022 ESM SHEET APPROVED BY OF17 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S ER O S I O N C O N T R O L D E T A I L S TREE PROTECTION FENCE SEE NOTE #3. TYPICAL FENCING FABRIC 1. 1 " 4' 10' MAX SPACING BETWEENSUPPORTS BU R Y 3' OR 2" X 4" (AS NEEDED) METAL "T" POST EXISTING TREE 4.2" NOTES: 1. PLACE CONTINUOUS RUN OF FENCE MATERIAL AS SHOWN ON PLANS. 2. ATTACH AT 10' MAXIMUM INTERVALS TO 2x4 POSTS. DO NOT STAPLE TO TREES. 3. FENCE MATERIAL SHALL BE 'TENSAR' HIGH STRENGTH POLYMER GEOGRID FABRIC BY TENSAR CORPORATION, MORROW, GEORGIA, OR EQUAL, BRIGHT ORANGE COLOR. 4. AT 100' O.C., PLACE SIGNS IN ENGLISH AND SPANISH: "NO TRESPASSING - TREE PROTECTION AREA" and "PROHIBIDO ENTRAR - ZONA PROTECTORA PARA LOS ARBOLES" 5. A PRE-CONSTRUCTION CONFERENCE SHALL BE HELD WITH THE PROJECT MANAGER AND THE TOWN'S LANDSCAPE ARCHITECT BEFORE ANY SITE WORK BEGINS. 6. ANY TREE ROOTS EXPOSED BY CONSTRUCTION SHALL BE SEVERED CLEANLY WITH A PRUNING TOOL. 7. THE SOIL WITHIN THE PROTECTED AREA AROUND EXISTING TREES SHALL NOT BE DRIVEN UPON AFTER FENCE REMOVAL FOR THE PURPOSE OF INSTALLING LANDSCAPING. 8. (2) LANDSCAPE SUPERVISORS ARE REQUIRED TO COMPLETE THE TOWN’S TREE PROTECTION FENCE SEMINAR. NO TRESPASSING TREE PROTECTION AREA PROHIBIDO ENTRAR ZONA PROTECTORA PARA LOS ÁRBOLES N.T.S. TEMPORARY DIVERSION BERM DETAIL 1. ACTUAL LAYOUT DETERMINED IN THE FIELD. 2. SIGNAGE IDENTIFYING THE CONCRETE WASHOUT AREA SHALL BE INSTALLED WITHIN 5FT.OF THE WASHOUT FACILITY. NOTES: B EARTHEN BERM B SECTION B-B NOT TO SCALE PERMEABLE GEOTEXTILE FABRIC CONCRETE WASHOUT TYPE "ABOVE GRADE" WITH EARTHEN BERMS STAPLES EARTHEN BERM PLYWOOD PAINTED WHITE LETTERSLAG SCREWS WOOD POST CONCRETE WASHOUT SIGN (OR EQUIVALENT) U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ D E T A I L S . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 7 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - CS8503 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 01/18/2022 ESM SHEET APPROVED BY OF18 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S ER O S I O N C O N T R O L D E T A I L S Sign Ove r h e a d P o w e r GM Patio Area CO CO FH T T T 8 Spaces 7 S p a c e s 4 S p a c e s 2 S p 2 Spaces 4 Spaces 5 S p a c e s 4 Sp a c e s 2 S p a c e s 2 S p 1 Sp 4 S p a c e s 12 Spaces Ove r h e a d P o w e r Two Story Brick-Veneer Building 6,675 Sqft± x26' High 54 . 7 ' 114.1' 12 . 4 ' 10.2' 42 . 3 ' 124.3' MA R K E T S T R E E T US H I G H W A Y # 1 7 B U S 10 0 ' R / W 8 OAK 24 OAK 8 OAK 8 OAK8 OAK 24 OAK (DBL) 18 OAK (DBL) 8 OAK 12 OAK 8 OAK 8 OAK 12 CMYRTLE 12 CMYRTLE 9 OAK 8 OAK 8 OAK 8 OAK 8 OAK 9 OAK 7 LIVE OAK 7 LIVE OAK 12 LIVE OAK8 LIVE OAK12 LIVE OAK 12 LIVE OAK 8 LIVE OAK 24 CMYRTLE 10 CMYRTLE 12 OAK 7 LIVE OAK9 LIVE OAK 8 OAK8 OAK 12 OAK 9 OAK 24 OAK (DBL) 15 LIVE OAK 8 CMYRTLE BUILDING HEIGHT 66.62' BUILDING HEIGHT 71.90' 12 LIVE OAK 10 OAK 8 LIVE OAK CMYRTLE CMYRTLE 8 PINE 8 PINE DBL OAK 18 10 CMYRTLE8 CMYRTLE 12 JAP MAPLE LP TANK TBM A ELEV= 45.17 TBM B ELEV= 39.77 GREASE TRAP T O P O F B A N K TO P O F B A N K BO T T O M O F B A N K BOTTOM OF BANK TOP OF BANK BOTTOM OF BANK EVIRF EVIPF EVIRF EVIPF BACK WATER FLOW VALVE PUMP HOUSE 10' WIDE WATER AND SEWER UTILITY EASEMENT; BK5255 PG445 30.00 2 0 . 0 0 APPROXIMATE DUKE ENERGY PROGRESS EASEMENTS PER DB6096; PG1312 18 . 0 0 ' 14 . 0 0 ' 10 . 0 0 ' 12.00' 3'R 3'R 24 . 0 0 ' 5.00'15.00' 8.50' 14 . 0 0 ' 14 . 0 0 ' 10'R 10'R 1 0'R 15'R 10'R 10 'R20'R 20'R 24 . 0 0 ' TAKE 5 CAR WASH EXPRESS 110' TUNNEL 50'R 8.50' 10'R 3'R 2 4'R 2 5 'R 5'R5'R 1 0'R 3 'R 24'R 10'R 8'R 3'R 10'R 5'R 5'R 5'R 25.00' 15.00' 7 DO NOT E N T E R DO NOT ENTER 2'R 10'R 8.00' 8.00' U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C S 9 2 0 1 . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 7 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - NOT FOR CONSTRUCTION CS9201 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 01/18/2022 ESM SHEET APPROVED BY OF19 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 20'40' PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 N O R T H TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S PR E / P O S T D E V E L O P M E N T I M P E R V I O U S A R E A TOTAL AREA: 65,575.35 SF (1.51 AC.) IMPERVIOUS AREA: 38,345.56 SF (0.88 AC.) PERVIOUS AREA: 27,229.79 SF (0.63 AC.) PRE-DEVELOPMENT IMPERVIOUS AREA PLAN POST DEVELOPMENT IMPERVIOUS AREA PLAN TOTAL AREA: 65,575.35 SF (1.51 AC) IMPERVIOUS AREA: 25,775.84 SF (0.59 AC) PERVIOUS AREA: 39,799.51 SF (0.92 AC) 3'R 3'R 10'R 10'R 10'R 15'R 10'R 10 'R20'R 20'R TAKE 5 CAR WASH EXPRESS 110' TUNNEL 50'R 10'R 3' R 2 4'R 2 5 'R 5' R 5'R 1 0'R 3 'R 24'R 10'R 8'R 3'R 10'R 5'R 5'R 5'R PROP. PROPERTY LINE (1.51 AC) DO NOT E N T E R DO NOT ENTER 2'R 10'R IN-1 MH-1 EX-DI IN-2 MH-2 IN-3 IN-5 IN-6 IN-8 IN-10 IN-12 YB-1 IN-11 IN-9 IN-7 CO-1CO-2CO-3CO-4 IN-4 PROP. ROOF DRAINS 4 5 46 40 41 41 4 1 42 4 3 42 43 44 45 4 24 3 44 45 44 44 41 44 46 41 4 4 44 44 43 42 42 43 41 4243 45 46 45 41 42 47 45 40 40 45 45 Ove r h e a d P o w e r GM CO CO FH T T T D r a i n a g e P o n d Ove r h e a d P o w e r MA R K E T S T R E E T US H I G H W A Y # 1 7 B U S 10 0 ' R / W 8 LIVE OAK 8 PINE 8 PINE DBL OAK 18 15" CMP DI RIM= 45.63 INV (NW)= 39.59 INV (N)= 41.59 INV (SE)= 39.44 INV (S)= 41.45 48" C M P 48" CM P DI RIM= 42.47 INV (NW)= 36.56 INV (SE)= 36.39 MH RIM= 46.93 INV= 40.11 48" CMP 15" C M P INV= 34.61 RIM= 34.04 INV=31.84 INV= 31.63 INV= 32.59 4 8 " C M P E O I CI RIM= 38.18 STRUCTURE FULL, CANNOT SEE PIPE SSMH RIM= 47.29 INV (IN)= 29.09 INV (OUT)= 28.39 10 " D I P EO I GREASE TRAP CI RIM= 45.73 INV= 41.87 1 5 " C P P CI RIM = 3 9 . 1 0 INV ( N W ) = 3 4 . 7 3 INV ( N E ) = 3 4 . 6 8 48 " R C P E O I 48" CMP T O P O F B A N K TO P O F B A N K B O T T O M O F B A N K BOTTOM OF BANK TOP OF BANK BOTTOM OF BANK EVIRF EVIPF EVIRF EVIPF 10' WIDE WATER AND SEWER UTILITY EASEMENT; BK5255 PG445 30.00 2 0 . 0 0 APPROXIMATE DUKE ENERGY PROGRESS EASEMENTS PER DB6096; PG1312 DRAINAGE TO: CO-1 DRAINAGE AREA: 0.03 AC IMPERVIOUS: 0.03 AC PERVIOUS: 0.00 AC DRAINAGE TO: CO-2 DRAINAGE AREA: 0.04 AC IMPERVIOUS: 0.04 AC PERVIOUS: 0.00 AC DRAINAGE TO: CO-3 DRAINAGE AREA: 0.03 AC IMPERVIOUS: 0.03 AC PERVIOUS: 0.00 AC DRAINAGE TO: IN-3 DRAINAGE AREA: 0.05 AC IMPERVIOUS: 0.04 AC PERVIOUS: 0.01 AC DRAINAGE TO: IN-4 DRAINAGE AREA: 0.02 AC IMPERVIOUS: 0.02 AC PERVIOUS: 0.00 AC DRAINAGE TO: IN-5 DRAINAGE AREA: 0.12 AC IMPERVIOUS: 0.11 AC PERVIOUS: 0.01 AC DRAINAGE TO: IN-6 DRAINAGE AREA: 0.06 AC IMPERVIOUS: 0.03 AC PERVIOUS: 0.03 AC DRAINAGE TO: IN-7 DRAINAGE AREA: 0.09 AC IMPERVIOUS: 0.088 AC PERVIOUS: 0.002 AC DRAINAGE TO: IN-8 DRAINAGE AREA: 0.06 AC IMPERVIOUS: 0.04 AC PERVIOUS: 0.02 AC DRAINAGE TO: IN-9 DRAINAGE AREA: 0.10 AC IMPERVIOUS: 0.097 AC PERVIOUS: 0.003 AC DRAINAGE TO: IN-10 DRAINAGE AREA: 0.04 AC IMPERVIOUS: 0.03 AC PERVIOUS: 0.01 AC DRAINAGE TO: IN-11 DRAINAGE AREA: 0.12 AC IMPERVIOUS: 0.114 AC PERVIOUS: 0.006 AC DRAINAGE TO: IN-12 DRAINAGE AREA: 0.08 AC IMPERVIOUS: 0.03 AC PERVIOUS: 0.05 AC DRAINAGE TO: YB-1 DRAINAGE AREA: 0.07 AC IMPERVIOUS: 0.00 AC PERVIOUS: 0.07 AC U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C S 9 2 0 2 . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 7 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - NOT FOR CONSTRUCTION CS9202 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 01/18/2022 ESM SHEET APPROVED BY OF20 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 20'40' PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 N O R T H TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S PO S T D E V E L O P M E N T I N L E T D R A I N A G E A R E A M A P MB S 4 2 ° 3 1 ' 4 5 " W 15 7 . 0 9 ' S 50°36'13" E 535.84' 15 7 . 1 5 ' ( R ) S 51°18'13" E 536.16'(R) N 45°18'27" W 466.61'(R) FH T T T MB S 4 2 ° 3 1 ' 4 5 " W 15 7 . 0 9 ' S 50°36'13" E 535.84' N 44°36'43" W466.52' 1.505 Acres ± 65575.3 Sq. Feet ± S 51°18'13" E 536.16'(R) N 45°18'27" W 466.61'(R) US H I G H W A Y # 1 7 B U S 10 0 ' R / W DBL OAK 18 10 " D I P EO I SSMH RIM= 48.71 INV (IN)= 29.51 INV (OUT)= 29.46 10 " D I P LP TANK TBM A ELEV= 45.17 TBM B ELEV= 39.77 GREASE TRAP TO P O F B A N K TOP OF BANK BOTTOM OF BANK EVIRF EVIPF EVIRF EVIPF @1+08.3 1.13' Lt FOUND 2" IRON PIPE UNKNOWNFOUND IRON PIN FOUND IRON PIPE 10' WIDE WATER AND SEWER UTILITY EASEMENT; BK5255 PG445 2 0 . 0 0 4 5 4 4 444 6474 7 474 8 44 43 42 45 43 42 41 4 8 4 7 4 6 4 7 46 45 44 43 42 41 4 0 3 9 3 8 3 7 3 6 35 3433 3 8 39 4 0 4 1 4 2 4 3 4 4 41 40 39 38 37 3635 34 4444 4 5 4 6 4 8 DO NOT E N T E R DO NOT ENTER Rear-Load Garba g e T r u c k FH T T T 1.505 Acres ± 65575.3 Sq. Feet ± US H I G H W A Y # 1 7 B U S 10 0 ' R / W DBL OAK 18 10 " D I P EO I SSMH RIM= 48.71 INV (IN)= 29.51 INV (OUT)= 29.46 10 " D I P LP TANK TBM A ELEV= 45.17 TBM B ELEV= 39.77 GREASE TRAP TO P O F B A N K TOP OF BANK BOTTOM OF BANK EVIRF EVIPF EVIRF EVIPF 10' WIDE WATER AND SEWER UTILITY EASEMENT; BK5255 PG445 2 0 . 0 0 4 5 4 4 444 6474 7 474 8 44 43 42 45 43 42 41 4 8 4 7 4 6 4 7 46 45 44 43 42 41 4 0 3 9 3 8 3 7 3 6 35 3433 3 8 39 4 0 4 1 4 2 4 3 4 4 41 40 39 38 37 3635 34 4444 4 5 4 6 4 8 DO NOT E N T E R DO NOT ENTER Pu m p e r F i r e T r u c k EX. FIRE HYDRANT 274' HYDRANT TO BLDG EXTENTS 266' HYDRANT TO BLDG EXTENTS 143' FIRE APPARATUS ACCESS TO BLDG EXTENTS 141' FIRE APPARATUS ACCESS TO BLDG EXTENTSPROP. FIRE APPARATUS ACCESS ROAD 150.00' 40 8 22 Pumper Fire Truck Overall Length 40.000ft Overall Width 8.167ft Overall Body Height 7.745ft Min Body Ground Clearance 0.656ft Track Width 8.167ft Lock-to-lock time 5.00s Max Wheel Angle 45.00° U: \ A c c o u n t s \ D R V B R \ D R V B R 2 2 0 4 0 - T a k e 5 C a r W a s h - W i l m i n g t o n N C \ D E S I G N \ _ S H E E T S \ C S 9 8 0 1 . d w g PL O T T E D : 3/ 1 5 / 2 0 2 3 5 : 5 8 P M , B Y : Ch r i s t o p h e r P a r r i s h PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : -- - - NOT FOR CONSTRUCTION CS9801 BY NO . DA T E RE V I S I O N S DRVBR22040 AS SHOWN DTR 01/18/2022 ESM SHEET APPROVED BY OF21 21 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60' PE N N O N I A S S O C I A T E S I N C . 54 3 0 W a d e P a r k B o u l e v a r d Su i t e 1 0 6 Ra l e i g h , N C 2 7 6 0 7 T 91 9 . 9 2 9 . 1 1 7 3 F 91 9 . 4 9 3 . 6 5 4 8 Fi r m L i c e n s e F- 1 2 6 7 N O R T H TA K E 5 C A R W A S H 82 3 2 M A R K E T S T R E E T WI L M I N G T O N , N C 2 8 4 1 1 44 0 S O U T H C H U R C H S T R E E T , S U I T E 7 0 0 CH A R L O T T E , N C 2 8 2 0 2 DR I V E N B R A N D S GA R B A G E T R U C K T U R N A N D F I R E T R U C K AP P A R A T U S A C C E S S P L A N 00 30'60' N O R T H GARBAGE TRUCK TURN PLAN 1" = 30' FIRE APPARATUS ACCESS ROUTE 1" = 30'